Gas Cooktops EW36GC55G S, EW36GC55G W, EW36GC55G B

Gas Cooktops EW36GC55G S, EW36GC55G W, EW36GC55G B
Gas Cooktops
EW36GC55G S, EW36GC55G W, EW36GC55G B
36" GAS COOKTOPS
Features
Deep-Well Formed Cooktop
Professional-Grade Burner Controls
Continuous Grates
Min-2-Max Dual-Flame Sealed Burner® – 18,000 - 450 BTU
Sealed Power Burner – 14,000 BTU
Sealed Precision Burner – 9,500 BTU
Sealed Precision Burner – 5,000 - 850 BTU
Linear Flow Burner Valves
Electric Pilotless Ignition
A.D.A. Compliant*
Yes
Yes
Yes
1
1
2
1
Yes
Yes
Yes
Accessories
Granite Countertop Installation Kit – PN # 903103-9010
Grill / Griddle – PN # 318251609
Wok Ring – PN # 318254307
Simmer Plate – PN # 318254208
LP Gas Conversion Kit
Optional
Mail-In Card
Optional
Optional
Included
Specifications
Min-2-Max Burner®
Designed with a dual-flame sealed burner,
this cooktop offers the widest range of BTU
performance in the industry for the utmost
versatility – from a roaring 18,000-BTU boil
to a gentle 450-BTU simmer.
Continuous Grates
Designed for cooking multiple dishes at varying
temperatures on a single cooktop. These grates
allow easy movement of even the heaviest pots
and pans from burner to burner – without lifting.
Color –
Stainless Steel
White
Black
Product Dimensions –
Width
Depth
Height (Extreme Bottom to Underside of Cooktop)
Gas / Power Supply Connection Location
Voltage Rating
Connected Load (kW Rating) @ 120 Volts ‡
Electrical Cable
Approved for Single Oven Combination Installation**
Shipping Weight (Approx.)
S
W
B
36"
21-3/4"
4-1/4"
Right Rear
120V / 60 Hz /15A
0.12
Yes
Yes
64 Lbs.
* When properly installed, meets the appliance standards in the Americans with Disabilities Act
and the Architectural Barriers Act Accessibility Guidelines as published by the United States
Access Board on June 23, 2004, as amended August 5, 2005.
‡For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate
ground wire. Appliance must be grounded for safe operation.
NOTE: Always consult local and national electric and gas codes. Refer to Product Installation Guide
for detailed installation instructions on the web at electroluxappliances.com.
Specifications subject to change.
**Approved to be used over any Electrolux Single Wall Oven.
Professional-Grade Control Knobs
Eliminate guesswork while cooking with more
precise control and better feel.
Deep-Well Design
Keeps spills contained for easy cleanup and
lowers the cooking surface to countertop level,
which makes moving oversized pots and pans
onto and off of the cooking surface much easier.
electroluxappliances.com
Gas Cooktops
EW36GC55G S, EW36GC55G W, EW36GC55G B
30" min.
for
unprotected
cabinet
36"
18"
min.
24" min.
for
protected
surface
21 3/4"
36"
13"
max.
cabinet
depth
4 1/4"
9" min. to nearest
combustible wall
(either side of unit)
33 1/4"
19"
2 3/4" minimum distance between
rear edge of cutout and nearest
vertical combustible surface
8" min.*
33 7/8" min.
34 1/4" max.
19 1/8" min.
3
/4" max.
19
25"min.
* Includes a 5" space beneath
cooktop for connection to
gas supply line
24"
36" Gas Cooktop Specifications
• Product
Weight – 53 Lbs.
Rating – 120V / 60 Hz / 15 Amps
• Connected Load (kW Rating) @ 120 Volts = 0.12 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
• Amps @ 120 Volts = 1.0 Amps
• Always consult local and national electric and gas codes.
• Recommended location for grounded 120V outlet is on rear wall in an
8" wide by 10" high area, positioned 22" above floor surface and 4" from
right side of cooktop centerline. Access to underside of cooktop and
junction box must be provided for inspection and service.
• Cooktop ships with 3/4" factory regulator.
• LP Gas conversion kit supplied.
• Overhead cabinetry should not exceed a 13" maximum depth.
• Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
• Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than 36".
• Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
• Voltage
• Allow
2-3/4" minimum distance between rear edge of cutout and
nearest combustible surface above countertop.
• Allow 9" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
• Installation of drawers beneath cooktop requires minimum 6-1/2"
clearance beneath countertop surface and assured clearance for gas
and electrical connections.
• To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond
bottom of cabinets.
• Gas Cooktop model EW36GC55G is approved to be used over any
Electrolux Electric Single Wall Oven. (Refer to Gas Cooktop Installation
Over 30" / 27" Electric Single Wall Oven Specifications page on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
• Granite
Countertop Installation Kit – (PN # 903103-9010).
Plate – (PN # 318254208).
• Wok Ring – (PN # 318254307).
• Simmer
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) • electroluxappliances.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca
EW36GC55G 02/13
© 2013 Electrolux Home Products, Inc.
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Gas Cooktop Installation
Over 30"/27" Electric Single Wall Oven
Cooktop
Manifold
pipe
Flare union
Flexible connector
Pressure regulator
Cabinet sides
and/or filler panel
Countertop
18" max.
61/2"
min.
5"
4"
Gas
Cooktop
Utility
Hookup
Flare
union 120V/60Hz
grounded outlet
Manual shutoff valve
(Must be accessible)
30" & 27" Electric Single Wall Ovens
Under-Counter Installation Specifications
Gas Cooktop Installation Over
30" / 27" Electric Single Wall Oven Specifications
• Product
Electrolux Single Wall Oven models EW30EW55G, EI30EW35J,
EI30EW35K, EW27EW55G, EI27EW35J and EI27EW35K are approved
to be used beneath Electrolux cooktop models EW36GC55G,
EW30GC55G and EW30GC60I.
For detailed Gas Cooktop installation, refer to model-specific
product page and installation guide on web.
• Side filler panels necessary to isolate oven from adjoining cabinets.
Panel height may need to be modified to accommodate the depth of
approved gas cooktop models.
• Minimum height opening of 6-1/2" (from top of counter) required in right
cabinet side panel and/or filler panel, to route gas and electric hookups.
• Allow 4-1/2" maximum height from oven base to floor, if cooktop is
installed directly over wall oven.
Weights – (EW30EW55G, EI30EW35J and EI30EW35K) 200 Lbs. /
(EW27EW55G, EI27EW35J and EI27EW35K) 150 Lbs.
• Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit fused
on both sides of line.
• Connected Load (kW Rating) @ 240 / 208 Volts =
(30") 4.0 / 3.0 kW / (27") 3.4 / 2.6 kW
• Amps @ 240 / 208 Volts = (30") 17.0 / 14.5 Amps / (27") 14.2 / 12.6 Amps
• Recommended Circuit Breaker – 20 Amps
• Always consult local and national electric codes.
• Minimum 21" clearance for oven door depth when open.
• Minimum 23-1/2" deep cutout dimension is critical for proper installation,
to ensure that oven’s faceplate will fit flush against cabinet front.
• Full oven base of solid plywood or similar material required, capable
of supporting 200 Lbs. (30" models) or 150 Lbs. (27" models). Install
over two runners and flush with toe plate.
• Base must be level and cabinet front must be square.
• Allow 5" maximum height from oven base to floor, if NO cooktop is
installed directly over wall oven.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) • electroluxappliances.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca
GC_EW INST EL 07/11
© 2011 Electrolux Home Products, Inc.
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Printed in the U.S.A.
Cooktop/Downdraft Vent
Countertop Preparation
Countertop Preparation for 30" & 36" Cooktop / Downdraft Vent Installation
For detailed cooktop and downdraft vent installation specifications, refer to model-specific product page and installation guide on web
Vertical noncombustible surface - rear wall
B
Top
23 1/4"
min.
Backsplash
/4" max.
3
2 9/16"
D*
1
E**
C
Flush with
back side of
cabinet front
25"
* Overall flat ledge behind
backside of cabinet front
** Minimum flat surface
required to fit top surface
of cooktop and downdraft
vent cap
A
E30DD75ESS / 30" Cooktop Cutout Dimensions
30" Cooktops
EW30IC60I
EW30CC55G
EW30EC55G
EW30GC55G
EW30GC60I
Countertop
backsplash
Studwall
3
A
30"
30"
30"
28 1/2"
28 1/2"
B
27 3/4"
27 3/4"
27 3/4"
27 3/4"
27 3/4"
C
20 1/2"
20 1/2"
20 5/8"
19 3/4"
19 3/4"
D
23 5/16"
23 5/16"
23 7/16"
22 9/16"
22 9/16"
E
24 5/16"
24 5/16"
24 7/16"
23 9/16"
23 9/16"
25" (standard countertop)*
/4" max. backsplash thickness
1
/4" min. flat ledge
213/16"
Countertop
Downdraft
raised lip
2 1/8"
chimney top
3"
9
Cooktop
/32"
1 15/16"
Vent unit
Back side of
cabinet front
Vertical noncombustible surface - rear wall
213/16"
Stiffener
/4" min.
flat ledge
E36DD75ESS / 36" Cooktop Cutout Dimensions
36" Cooktops
EW36IC60I
EW36CC55G
EW36EC55G
EW36GC55G
A
36 1/4"
36 1/4"
36"
34 1/4"
B
33 3/4"
33 3/4"
33 3/4"
33 3/4"
C
20 1/2"
20 1/2"
20 5/8"
19 3/4"
D
23 5/16"
23 5/16"
23 7/16"
22 9/16"
E
24 5/16"
24 5/16"
24 7/16"
23 9/16"
Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements. Due to varying cooktop depths, tight fit
is possible between cooktop and vent.
Countertop Preparation Note:
Be aware of areas of potential interference called out in
illustration. Countertop with raised lip and/or backsplash may
not allow enough flat area for proper installation, 2-13/16"
of flat countertop required behind cooktop. No gap required
between back of cooktop and front of downdraft trim piece.
*Standard 25" countertop depth may NOT be adequate for
some cooktop/vent installations, especially with backsplash.
23 1/4" min.
Cooktop / Downdraft Vent
Countertop Preparation Specifications
• For
detailed Cooktop installation, refer to model-specific product page
and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
• Position cooktop / vent cutout so all required minimum clearances are met.
• Minimum flat countertop area must meet or exceed combined overall
width and depth as shown. Standard 25" countertop depth may NOT be
adequate for some cooktop / vent installations, especially with backsplash.
• Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
• Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.
Downdraft Vent Specifications
• For
detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
• Voltage Rating – 120V / 60 Hz / 15 Amps
• Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
• Amps
@ 120 Volts = 8.0 Amps
unit outside of building only.
• Vent must be installed in vertical orientation only.
• 1,600 CFM remote exhaust blower (PN # 5304444802) included with
vent – shipped in separate box.
• Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
• When multiple elbows are necessary, ensure a minimum of 24" of
straight duct between any two elbows.
• Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
• For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
• Cold weather installations should have additional backdraft damper
installed.
• Installing a Downdraft Vent in combination with any gas cooking
surface will affect optimum burner efficiency.
• Vent
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) • electroluxappliances.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca
DIC_DDV_PREP EL 10/10
© 2010 Electrolux Home Products, Inc.
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Printed in the U.S.A.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising