HTSD12X 12X Optical Zoom Indoor / Outdoor Speed Dome Camera Please read this manual thoroughly before operation and keep it handy for further reference. CONTENTS Warning & Caution 3 What’s in the Box? 3 General Features Overview of Parts 4 5 Installation A. Connection Methods B. Ceiling Mount Type 6 7 C. Embedded Mount Type Quick Operation Keys Diagnostic 8 9 OSD Menu Setting A. OSD Menu Table 10 B. DOME SET 11 C. CAMERA SET 16 D. PRESET 18 E. AUTO SCAN 19 F. TOUR SET 20 G. PRIVACY SET 21 H. PATTERN SET 22 I. ALARM SET 23 J. SECTOR SET 24 DIP Switch Setting A. ID Setting (DIP SW1) B. Protocol/ Baud Rate Setting (DIP SW1-9~10) Trouble Shooting 25 26 27 Specification 28 Dimension 29 2 WARNING & CAUTION If you fail to read this information and handle the product incorrectly, death or serious injury may occur. The unit should be installed by a trained professional Immediately stop usage when the product emits smoke or abnormal heat. Never install the product in an area exposed to water, oil or gas. This symbol is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Never install the product on a ceiling that cannot hold its weight. This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Never touch the power cord with wet hands. Clean only with dry cloth. Warning Never install the product in extreme high or low temperature. Never operate Pan/Tilt with hands. It may cause serious damage to the camera. Never drop, hit strongly, or vibrate the product. Never expose the product to direct sunlight or severe ray. What’s in the Box ? 1. Camera 2. Screws ( Ø4x16 screw Never touch the front glass of the product. 5EA ) 3. Terminal block (6pin 1EA,5pin 1EA) 4. Manual Never install the product in areas exposed to 5. Screw Cap (2 EA) rain or water 3 GENERAL FEATURES 144X Zoom Mini Speed Dome Quick Operation Keys 12X Optical Zoom with 12X digital zoom This camera provides quick functional keys to be easily controllable by another controller or DVR. ±0.02° dome system accuracy with 1/4 micro step Various Surveillance Functions With 0.1° technical accuracy, camera provides excellent sensitive and delicate controlling on preset mode by adapting 1/4 micro step and twin gear system Auto Scan repeats pan and tilt between two preset 360° Endless Rotation 12X mini speed dome is capable of endless rotation of 360 degrees Compensation function: preset position The function minimizes the appearance of shaky images caused by low-frequency vibration, wind and any impact and maintains a normal horizontal resolution. Sets the starting point of pan/tilt on preset mode by using joystick turning one time without turning off the power of the camera. It is useful for outdoor surveillance and traffic monitoring applications. ° Over 240 /Sec Preset Speed The 360° full pan function moves at a maximum of 240°/sec., enabling you to quickly pinpoint the spot you want to watch. Tilt speed is a maximum 240°/sec on preset. Polarity Protection of Power This protection function prevents the power board from being damaged when the power source connects to an incorrect power terminal. Filter changeable True Day/Night Surveillance with optimum picture is possible owing to filter changeable Day/Night (ICR block filter) function and DSS. The auto IR cut filter removable function controls operation such as color picture plus infrared cut filter during the day and black and white picture plus filter elimination at night. positions with different speed and dwell time. 8 Group Tour up to 8 Programmable Group tours available and each group is consisting up to 60 presets step with different speed and dwell time with 16 characters. 164 Preset positions up to 164 programmable preset positions are available with 16 characters 8 Patterns up to 8 programmable user-defined patterns are available with 16 characters and each one consists of 50 seconds, up to total 400 seconds. 8 Sectors up to 8 programmable user-defined sectors are available with 16 characters 4 Privacy Masking Zones up to 4 programmable user-defined privacy masking zones are available with 16 characters 4 Alarm input up to 4 alarms can be activated with preset, tours, patterns. ° 240 /S – Manual speed This camera provides up to 240°/sec of manual speed and is adjustable from 1°/sec to 240°/sec at an interval of 10°/sec 1/4” Sony Super-HAD CCD Equipped with Sony Super-HAD CCD technology, this camera provides excellent sensitivity and low smear levels. Intelligent Pan/Tilt Controlling Intelligent Pan/Tilt function decreases pan and tilt speeds in proportion to zoom. Aluminum case and PC cover Aluminum body and Poly Carbonate dome (IP66 Rated) . Indoor / Outdoor applications Compact and minimal dome size allows for various install applications Password Protection 4 OVERVIEW OF PARTS 1. Surface Mount Adaptor 2. Cap Screw ( PT3/4 , 2EA ) 3. Dip Switch 4. Terminal Block 5. Main body 5 INSTALLATION A. CONNECTION METHOD A-1 1. 2. 3. 4. 5. 6. Loosen the screws on the dome cover and remove it from the base. (Screws will not fall out) Loosen the screws which connect mount cover and Main base and separate dome cover from the main base. (Screws will not fall out) Connect power (12VDC or 24VAC) Connect video to Video and GND. Connect communication cable to RS-485 connectors. Connect alarm cable to GND like 1 and GND, 2 and GND, 3 and GND, 4 and GND. (You can use both N.O / N.C methods.) Don’t screw too tightly. It can be the cause of a defect. 6 INSTALLATION B. MOUNT 1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to install. (FIG.4) 2. When you use pipe, please note the standard size of pipe. (FIG.5) 3. Re-assemble the domes. 7 QUICK OPERATION OPERATION KEYS 1-64 + preset and 101~200 + preset are used for preset and 65-100 + preset used for functions. For example, to enter OSD MENU, press the button 95 +PRESET or 95 +ENTER <Quick Operation Key Table 1, Pelco - D, P> Number 1 ~ 64, 101~200 +Preset 65 + Preset 66 +Preset 67 +Preset 71~78 +Preset 81~88 +Preset 91 + Preset 92 + Preset 93 + Preset 94 + Preset 95 + Preset 96 + Preset 97 +Preset Note PRESET PRESET STATUS AUTO SCAN AUTO FLIP GROUP TOUR PATTERN ZERO POSITION FREEZE BLC MODE D/N MODE OSD MAIN MENU FOCUS ADJUST ALARM Function Executing Preset 1 ~ 64 Display Preset Status Executing Auto Scan Selectable On/Off/Auto in Auto Flip function Executing Group Tour #1 ~ #8 Executing Pattern #1 ~ #8 Selectable On/Off in BLC function Selectable Day/Night Mode (Auto/Day/Night Mode) To enter OSD Main Menu Focus adjusting Selectable Enable/Disable all Alarms <Quick Operation Keys Table 2> Use these function keys if controller has these keys> Menu Tilt Up / Down Pan Left / Right Focus Near Focus Far Zoom Tele Zoom Wide Function Sub menu cursor moves up / down Enter to the sub menu or status change or decrement Using for Enter key when user select YES or NO Using for function changing keys when set coordinate Status cursor to the right Status cursor to the left * 65 + preset: Status Report, if user presses ‘Near’ key, it disappears. 8 QUICK OPERATION OPERATION KEYS DIAGNOSTIC When Power is on, DIAGONOSTIC is operational. The following messages are displayed on the monitor. CAMERA ID : 001 BAUD RATE : 2400 BPS WAITING……… A. PAN ORIGIN CHECK OK TILT ORIGIN CHECK OK TX CONNECTION TEST OK CAMERA COMM TEST OK Pan Origin Test Zero point of Pan is found after Panning test. B. Tilt Origin Test Zero point of Tilt is found after Tilting test. C. TX connection Test Countdown from 60 seconds for TX Connection Test, During 60 seconds, the camera must receive a signal from any key of the controller or DVR. When received the correct signal, OK is displayed after TX CONNECTION TEST. * If “No Tested” is displayed on the monitor, - Camera did not receive the any signal. - Camera did receive the signal but did not correct it. - User should check protocol, baud rate and RS-485 connection. D. Camera Comm. Test Communication test with the camera is automatically checked. OK should be displayed in these four tests before installation. If all the above Tests are OK, “NOW EEPROM CHECKING” and “EEPROM OK” is displayed and the camera is ready to operate. 9 ZOOM SPEED WB MODE PIC FLIP : OFF/ON : FAST : DISABLE : 01 TOUR SET : BLK PRESET NO : 200 /S CONFIRM [SYSTEM STATUS] 10 [PREVIOUS PAGE] [INITIALIZATION] PASSWORD *** *** BY ENTERING PRESET CODE EXIT SAVE : 01 EXIT SAVE ALARM ACT ALARM INPUT FIRMWARE VER.:3.00 UPGRADED DATE: 12.08.10 SECTOR ID: OFF ON COORDINATE:ON/OFF AUTO SCAN SET : 03 [INITIALIZATION] [LOAD OPTIMIZED DEFAULT [REVIOUS PAGE] [PATTERN CLEAR] [PRIVACY CLEAR] [SECTOR CLEAR] [PRESET CLEAR] [TOUR CLEAR] EXIT SAVE SECTOR END : XXX.X.XX.X SECTOR START: XXX.X.XX.X SECTOR ID : SECTOR01□□□ SECTOR NO : 01 [PREVIOUS PAGE] : 001 : OFF EXIT SECTOR SET : 10 : OFF/ON : CW : XXX.X.XX.X SAVE AND EXIT DWELL TIME SPEED ENDLESS DIRECTION END ANGLE START ANGLE : XXX.X.XX.X VIDEO TYPE : NTSC CAMERA MODULE:SCC-ZM123 BAUD RATE: 2400BPS PRESET ID: OFF/ON [PREVIOUS PAGE] PROTOCOL : PELCO D,P [SYSTEM STATUS] : 000% : 01 ALARM SET ALARM NO. CAMERA ID: OFF/ON OSD DISPLAY EXIT DATA FILL EXIT [OSD DISPLY] PRESET ID: PRESET01□□□□□□□□□ PAN:XXX.X.XX.X TILT:XXX.X.XX.X PATT TITLE PATTERN01□□□ SAVE [PASS WORD ] PRESET SET PRESET NO: 001 PATTERN SET PATT NO. SAVE : OFF : MOVE ACTION : 01 PRIVACY SET EXIT DSS MODE : OFF/ON DISPLAY ENTER PASSWORD PASSWORD : OFF/ON : ATW2 MODE D/N MODE : AUTO MODE PRIVACY NO. SYSTEM LOCK : OFF/ON EXIT SAVE AND EXIT SPEED DWELL TIME : 03 : 01 TOUR STEP TOUR TITLE : TOUR01□□□□□□ TOUR NO. EXIT SAVE AND EXIT [NEXT PAGE] BLC D ZOOM : OFF LANGUAGE : ENGLISH ALARM APERTURE : 02 : 100 /S : OFF/ON : OFF/ON MIRROR : OFF ° NEXT PAGE EXIT SECTOR ALARM PATTERN PRAVACY TOUR AUTO FLIP : OFF/ON CAMERA SET FLICKER : CAM1□□□□□□□□□□□□ DOME SET MANUAL SPEED RECOVER CAMERA ID ° AUTO SCAN PRESET CAMERA SET DOME SETUP MAIN MENU OS D MENU MENU S ETTING A. OSD MENU TABLE OS D MENU MENU S ETTING To enter OSD Menu, press the button 95 + PRESET. MAIN MENU DOME SETUP PRESET CAMERA SET AUTO SCAN TOUR PRIVACY PATTERN ALARM SECTOR EXIT *Move the joystick up / down to highlight the selection and left / right to make the selection B. Dome Setup To enter Dome setup, move the joystick to the right when the setting is highlighted DOME SET CAMERA ID : CAM1□□□□□□□□□□□□ RECOVER : OFF MANUAL SPEED : 100°/S AUTO FLIP : OFF ZOOM SPEED : FAST ALARM : DISABLE LANGUAGE : ENGLISH [NEXT PAGE] SAVE AND EXIT EXIT B-1. DEFAULT SETTING DOME SET - CAMERA ID To set camera ID, select up to 16 characters using Joystick to the left or right. Press ZOOM TELE button to move to the next character from left to right direction and ZOOM WIDE button to move to the next character from right to left direction (Space displays when appears) 11 OS D MENU MENU S ETTING B-2. DOME SET - RECOVER This feature allows the dome to recover to the last setting before the dome was used manually (Auto scan, group tour, pattern or sectors), after the set time, power will shut down and turn back on. Recover time can be programmed from 15 second to 90 seconds. The default setting is OFF. B-3. DOME SET - MANUAL SPEED Manual Speed of Pan/Tilt is selectable from 1°/sec up to 240°/sec. The default setting is 100°/sec B-4. DOME SET - AUTO FLIP Auto Flip is available and the default setting is OFF. Move joystick “right or left” to select ON or OFF. The default setting is OFF. This function can be recalled by pushing 67+ preset button. B-5. DOME SET – ZOOM SPEED Zoom speeds are selectable FAST or SLOW mode. Move joystick to the right direction for selecting FAST or SLOW. The default setting is FAST. B-6. DOME SET – ALARM All alarms are available after set as ENABLE Mode. Move joystick to right or left direction for selecting ENABLE/DISABLE. The default setting is DISABLE. This function can be recalled by pushing 97 + preset button. B-7. DOME SET - LANGUAGE Multiple languages are selectable here including English, Italian and Polish. right or left direction to select language. Move joystick to the The default setting is ENGLISH. B-8. DOME SET – [NEXT PAGE] DOME SET SYSTEM LOCK: : OFF [PASS WORD] [OSD DISPLAY] [SYSTEM STATUS] [INITIALIZATION] [PREVIOUS PAGE] DEFAULT SETTING B-8-1. DOME SET – [NEXT PAGE] – SYSTEM LOCK Password protection allows settings to be stored. One then must enter the correct password to change the settings. In order to enter [PASS WORD] page, system lock status is must set as ON. Move joystick to right or left direction to select ON. The default setting is OFF. 12 OS D MENU MENU S ETTING B-8-2. DOME SET – [NEXT PAGE] – [PASSWORD] To enter this page to set a password, SYSTEM LOCK should be ‘ON’ then move joystick to the right direction on [PASSWORD]. The password must be set by preset number from 001 to 255 (Default 99) A. OSD MAIN MENU TABLE (PAGE 11) The default setting is BLANK. ENTER PASSWORD BY ENTERING PRESET CODE PASSWORD *** CONFIRM *** Press any number from 001~255 with preset button on password blank and again it on confirm blank. Then “CONFIRMED” is displayed on the monitor and the menu will go back to the previous page automatically. ENTER PASSWORD ENTER PASSWORD BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***CONFIRMED BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***CANCELLED <CONFIRMED> <CANCELLED> If user presses wrong preset number between PASSWORD and CONFIRM, “CANCELLED” is displayed on the monitor and if user failed 3 times, the menu will return to the previous page automatically * After setting a Password, an operator must enter the correct password in order to enter OSD MAIN MENU, or to change the settings. * An operator must remember the password for the operation. Manufacturer doesn’t provide password recovery. B-8-3. DOME SET – [NEXT PAGE] – [OSD DISPLAY] OSD ID displayed after set ON in here and it can be hiding if selected OFF. Move joystick to the right or left direction in order to select OFF/ON when the cursor is located each item. 13 OS D MENU MENU S ETTING OSD DISPLAY CAMERA ID : PRESET ID : SECTOR ID : COORDINATE : [PREVIOUS PAGE] OFF OFF OFF ON DEFAULT SETTING B-8-4. DOME SET – [NEXT PAGE] – [SYSTEM STATUS] This page shows the information of this camera. SYSTEM STATUS PROTOCOL : BAUD RATE : FIRMWARE VER. : UPGRADED DATE : CAMERA MODULE : VIDEO TYPE : [PREVIOUS PAGE] PELCO D, P 2400 BPS 3.00 12.08.10 SCC-ZM123 NTSC/PAL DEFAULT SETTING - Protocol and baud rate are shown according to the dip switch setting (Refer to page 29, 30 and 31) - Firmware version and upgraded date will be changed if upgraded. - Below camera modules can be set as follows. SCC-ZM123: SAMSUNG 12X ZOOM CAMERA MODULE. B-8-5. DOME SET – [NEXT PAGE] – [INITIALIZATION] To clear all memorized data for tour, preset, sector, privacy or pattern, move joystick to the right direction when the cursor is on [INITIALIZATION] INITIALIZATION [TOUR CLEAR] [PRESET CLEAR] [SECTOR CLEAR] [PRIVACY CLEAR] [PATTERN CLEAR] [LOAD OPTIMIZED DEFAULT] [PREVIOUS PAGE] 14 OS D MENU MENU S ETTING - To clear any stored setting, move joystick to the right direction when cursor is on each item. TOUR CLEAR TOUR CLEAR ARE YOU SURE? YES NO Press FOCUS NEAR button when the cursor is at YES in order to clear the setting. item such as tour, preset, sector, etc will flicker on the monitor for about 2~3 seconds. Then each After this process, the menu is returned to the previous page. * [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR], [PATTERN CLEAR] are same as [TOUR CLEAR]. LOAD OPTIMIZED DEFAULT ALL DATA INITIALIZING ARE YOU SURE? YES NO - To clear all data and return to factory default, move joystick to the right direction when cursor is at [LOAD OPTIMIZED DEFAULT] to enter the above page. - Move joystick to the right or left direction in order to select YES, press FOCUS NEAR button. - “ALL DATA INITIALIZING” will be displayed for 5~7 seconds and then the menu will be returned to the previous page automatically. B-9. DOME SET – [NEXT PAGE] – SAVE AND EXIT To save the settings and leave this page, move joystick to the right direction when cursor is at SAVE AND EXIT. B-10. DOME SET – [NEXT PAGE] – EXIT In order not to save any setting and leave the page, move joystick to the right direction when cursor is at EXIT 15 OS D MENU MENU S ETTING C. CAMERA SET CAMERA SET FLICKER MIRROR APERTURE D ZOOM WB MODE PIC FLIP BLC D/N MODE DSS MODE EXIT : : : : : : : : : OFF OFF 02 OFF ATW2 MODE OFF OFF AUTO MODE OFF C-1. CAMERA SET - FLICKERLESS Flickerless feature is selected between 50Hz and 60Hz. PAL: 50Hz). The default setting is OFF (NTSC: 60Hz / Set flicker mode ON when power source is in discord with frequency. The default setting is OFF C-2. CAMERA SET - MIRROR This feature shows a mirror image. The default setting is OFF. C-3. CAMERA SET – APERTURE Aperture enhances picture details by increasing gain of the camera and sharpens the edges in the picture. The default setting is 02. (the aperture level is from 00 ~ 03) C-4. CAMERA SET – D ZOOM Move joystick to the right direction in order to set as ON. The default setting is OFF. C-5. CAMERA SET – WB MODE White balance functions have 4 modes according to the condition of exterior lighting. It may change the mode option according to the lighting conditions as below. The default setting is ATW2 mode ATW1 Mode - 2,500°K to 9,500°K ATW2 Mode - 2,000°K to 10,000°K Indoor – up to 3,200°K Outdoor – up to 5,600°K 16 OS D MENU MENU S ETTING C-6. CAMERA SET – PIC FLIP Flips the picture horizontally. Move joystick to the right or left direction to select OFF/ON. The default setting is OFF. C-7. CAMERA SET – BLC (Back Light Compensation) The default setting is OFF and BLC modes can be OFF/ON. OFF – Backlight compensation is not activated. ON – Back light compensation is activated. This function can be recalled by pushing 93 + preset button. C-8. CAMERA SET – D/N MODE ICR filter is changeable according to the lighting, AUTO – NIGHT MODE – DAY MODE. The default setting is AUTO MODE. This function can be recalled by pushing 94 + preset button. C-9. CAMERA SET – DSS MODE (DIGITAL SLOW SHUTTER) If DSS is turned on, digital slow shutter is working. The DSS will remain open to receive some more lighting. The default setting is OFF. C-10. CAMERA SET – EXIT To leave this page, move joystick to the right. 17 OS D MENU MENU S ETTING D. PRESET SET To enter PRESET SET, move joystick to the right direction. PRESET SET PRESET NO :001 PRESET ID :PRESET001------PAN :XXX.XX TILT : XXX.XX SAVE EXIT D-1. DEFAULT SETTING PRESET – PRESET NO. Up to 164 numbers of preset positions are available. Move joystick to the right or left direction to select preset no. D-2. PRESET – PRESET ID To set preset ID, select up to 16 characters using Joystick to the left or right. Press ZOOM TELE button moves to the next character from the left to the right direction and ZOOM WIDE button moves to the next character from the right to left direction (Space displays when appears) D-3. PRESET – PAN: XXX.X TILT: XX.X Press FOCUS FAR button in order to set preset position, then, use the joystick move the camera to the position where memorized preset no. is needed. Then press FOCUS FAR button again after setting a preset location. D-4. PRESET – SAVE Move joystick to the right when the cursor is at SAVE and then the cursor will be located on Preset ID for the continuous preset No. setting. D-5. PRESET – EXIT To leave this page, move joystick to the right. 18 OS D MENU MENU S ETTING E. AUTO SCAN SET * 66 + preset button is working as AUTO SCAN after setting. AUTO SCAN SET START ANGLE END ANGLE DIRECTION ENDLES SPEED DWELL TIME SAVE AND EXIT EXIT : : : : : : XXX.X.XX.X XXX.X.XX.X CW OFF 10°/S 03 DEFAULT SETTING E-1. AUTO SCAN – START ANGLE To set start angle, press FOCUS FAR button then use the joystick to move the camera to the desired starting angle. Press FOCUS FAR button again leave. E-2. AUTO SCAN – END ANGLE To set end angle, press FOCUS FAR button use the joystick to move the camera to the desired starting angle. Press FOCUS FAR button again leave. E-3. AUTO SCAN – DIRECTION Auto Scan directions are available with two direction as CW or CCW by joystick to the right or left CW: Clock-wise direction (Default) CCW: Counter Clock-Wise Direction. E-4. AUTO SCAN – ENDLESS Auto Scan can use endless rotation, move joystick to the right direction in order to select ON. Otherwise, the default setting is OFF. E-5. AUTO SCAN – SPEED User can use auto scan speed from 01°/S up to 35°/S. The default setting is 10°/S. E-6. AUTO SCAN – DWELL TIME To select dwell time, move joystick to the left or right direction in order to adjust dwell time. This can be set from 1 second to 99 seconds. The default setting is 3 seconds. E-7. AUTO SCAN – SAVE AND EXIT To save the settings leave this page, move joystick to the right when cursor is at SAVE AND EXIT. E-8. AUTO SCAN – EXIT To leave this page, move joystick to the right. 19 OS D MENU MENU S ETTING F. TOUR SET 8 Programmable tours can be set and each tour is available to set up to 60 preset steps. After setting the data to the each tour group, 71~78 + preset buttons are working as group tour # 1~8 TOUR SET TOUR NO TOUR TITLE TOUR STEP PRESET NO. DWELL TIME SPEED SAVE EXIT : : : : : : 01 TOUR01□□□□□□□□□□ 01 BLK 03 200°/S DEFAULT SETTING F-1. TOUR SET – TOUR NO. Max. 8 group tour no. set by the joystick are available. F-2. TOUR SET – TOUR TITLE To set tour title, select up to 16 characters using Joystick to left or right. Press ZOOM TELE button to move the next character from the left to the right direction and ZOOM WIDE button to move the next character from the right to left direction (Space displays when appears) Tour title is not displayed on the monitor, but only for the reference of user. F-3. TOUR SET – TOUR STEP Each tour group consists of up to 60 preset steps with different dwell time and speed. It is possible to match any preset # for each tour step. F-4. TOUR SET – PRESET NO. The decided tour step #1~60, it is possible to select any preset no. up to 164. The default setting is BLK F-5. TOUR SET – DWELL TIME Dwell time can be set from 1 second to 99 seconds. The default setting is 3 seconds. F-6. TOUR SET – SPEED Each tour step can be set with different tour speed up to 240°/S and it is selectable from 10°/S. Move joystick to the right or left direction to select tour speed. The default setting is 200°/S. F-7. TOUR SET – SAVE To save the settings and leave this page, move joystick to the right when cursor is at SAVE F-8. TOUR SET – EXIT To escape this page, move joystick to the right direction 20 OS D MENU MENU S ETTING G. PRIVACY SET 4 Privacy masking zones are available to block out areas of security. PRIVACY SET PRIVACY NUMBER : 01 DISPLAY : OFF ACTION : MOVE SAVE EXIT DEFAULT SETTING G-1. PRIVACY SET – PRIVACY NUMBER. Up to 4 privacy masking zones are available. G-2. PRIVACY SET – DISPLAY. Move joystick to the right or left direction to set ON in order to show the selectable block in the center of the monitor. This block appears as a translucent square with blue color after set ON. The default setting is OFF. G-3. PRIVACY SET – ACTION (MOVE / POINT) To set the privacy area, press FOCUS FAR button when on MOVE MODE. Then use the joystick to the user defined area in order to set blocking area. Then press FOCUS FAR button again to leave MOVE MODE. To adjust size of privacy area, move joystick to the right or left direction when the cursor is on ACTION. After move mode is changed to POINT MODE, press FOCUS FAR button in order to adjust the size of privacy area. The size of blocking area can be adjustable by using joystick up down or left right. After adjusting size of blocking area, press FOCUS FAR button to leave escape POINT mode. POINT: You can change the masking size by using joystick to the left or right direction MOVE: You can move the masking area by using joystick to the left or right direction (Default) G-4. PRIVACY SET – SAVE After setting the privacy masking zone, to save the data, move joystick to the right when the cursor is on SAVE. After saving the data, the cursor moves to PRIVACY NO.2 automatically to prepare the next privacy masking zone. G-5. PRIVACY SET –EXIT To escape this page, move joystick to the right direction 21 OS D MENU MENU S ETTING H. PATTERN SET 8 programmable patterns are available with 16 characters of title. After setting the data to each pattern # 1~8, 81~88+ preset buttons are working as Pattern # 1~8. PATTERN SET PATT NO : 01 PATT TITLE: PATTERN01□□□□□□□ DATA FILL : 000% SAVE EXIT DEFAULT SETTING H-1. PATTERN SET –PATT NO. Up to 8 programmable user-defined patterns set by the joystick are available. H-2. PATTERN SET –PATT TITLE To set PATTERN TITLE, select up to 16 characters using Joystick to the left or right. Press ZOOM TELE button moves to the next character from the left to the right direction and ZOOM WIDE button moves to the next character from the right to left direction (Space displays when appears) Pattern title is not displayed on the monitor, but only for reference. H-3. PATTERN SET –DATA FILL To fill the programming data, press FOCUS FAR button in order to start the data fill up. Filling data is programmed according to the joystick movement. Press FOCUS FAR button again in order to leave. H-4. PATTERN SET –SAVE To save the setting, move joystick to the right when the cursor is on SAVE. Then the cursor moves to the PATT NO.02 in order to prepare next pattern no. H-5. PATTERN SET –EXIT To leave this page, move joystick to the right 22 OS D MENU MENU S ETTING I. ALARM SET 4 Alarm inputs are available and each alarm is activating to presets, group tours or patterns. ALARM SET ALARM NO : 01 ALARM INPUT: OFF ALARM ACT : 001 SAVE EXIT DEFAULT SETTING I-1. ALARM SET – ALARM NO. Up to 4 alarms are selectable by using joystick to the right direction when cursor is on ALARM NO. I-2. ALARM SET – ALARM INPUT Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal Close) The default setting is OFF I-3. ALARM SET – ALARM ACT Alarm activates various surveillance modes with Preset number up to 164, Group tour up to 8, Pattern up to 8. Move joystick to the right or left direction to select any preset number, group tour no. or pattern no. I-4. ALARM SET – SAVE After setting the alarm input ways and activation, to save the data, move joystick to the right when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2 automatically to prepare the next alarm. I-5. ALARM SET –EXIT To escape this page, move joystick to the right * Before activating Alarm, user must set ALARM ENABLE at DOME SET – ALARM – ENABLE (Refer to page 15) 23 OS D MENU MENU S ETTING J. SECTOR SET Up to 8 programmable sectors are available with 16 characters. This feature is useful to store certain locations such as parking zone, etc. When the camera scans this area, it shows the stored value. SECTOR SET SECTOR SECTOR SECTOR SECTOR SAVE EXIT Start Position NO : 01 ID: SECTOR01□□□□□□□□ START: XXX.X.XX.X END : XXX.X.XX.X End Position DEFAULT SETTING J-1. SECTOR SET – SECTOR NO. Up to 8 programmable sectors set by the joystick are available. J-2. SECTOR SET – SECTOR ID To set SECTOR ID, select up to 16 characters by using Joystick to the left or right. Press ZOOM TELE button to move to the next character from the left to the right direction and ZOOM WIDE button to move to the next character from the right to left direction (Space displays when appears) J-3. SECTOR SET – SECTOR START To set SECTOR START angle, press FOCUS FAR button then move joystick to the left or right direction to set the position. Press FOCUS FAR button again to leave. J-4. SECTOR SET – SECTOR END To set SECTOR END angle, press FOCUS FAR button then move joystick to the left or right direction to set the position. Press FOCUS FAR button again to leave J-5. SECTOR SET – SAVE After setting the SECTOR position, to save the data, move joystick to the right direction when the cursor is on SAVE. After saving the data, the cursor moves to SECTOR NO.2 automatically to prepare the next SECTOR. J-6. SECTOR SET –EXIT To leave this page, move joystick to the right K. EXIT To leave the OSD Main Menu, move joystick to the right or left direction then this camera is ready to operate. 24 DIP SWITCH SETTING A-1. DIP SW SETTING Mini Speed Dome camera provides up to 63 camera ID and it’s an adjustable ID with 1st~6th of Dip switch. Open the camera case to set ID using DIP SW1. * Factory default: Camera ID = 1, PELCO-D Termination Baud rate Protocol ID Set A-2. ID SETTING (1-ON, 0-OFF) (110) DIP SW 100000XXXX 010000XXXX 110000XXXX 001000XXXX 101000XXXX 011000XXXX 111000XXXX 000100XXXX 100100XXXX 010100XXXX 110100XXXX 001100XXXX 101100XXXX 011100XXXX 111100XXXX 000010XXXX 100010XXXX 010010XXXX 110010XXXX 001010XXXX 101010XXXX 011010XXXX ID VALUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 DIP SW 111010XXXX 000110XXXX 100110XXXX 010110XXXX 110110XXXX 001110XXXX 101110XXXX 011110XXXX 111110XXXX 000001XXXX 100001XXXX 010001XXXX 110001XXXX 001001XXXX 101001XXXX 011001XXXX 111001XXXX 000101XXXX 100101XXXX 010101XXXX 110101XXXX 001101XXXX ID VALUE 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 DIP SW 101101XXXX 011101XXXX 111101XXXX 100011XXXX 100011XXXX 010011XXXX 110011XXXX 001011XXXX 101011XXXX 011011XXXX 111011XXXX 000111XXXX 100111XXXX 010111XXXX 110111XXXX 001111XXXX 101111XXXX 011111XXXX 111111XXXX ID VALUE 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 44 25 DIP SWITCH SETTING A-3. PROTOCOL 7th~8th dip switches are used for Protocol Setting. Factory Default: Pelco-D or Pelco-P (Auto detection) DIP SW1- 7 DIP SW1- 8 OFF OFF Pelco-D or Pelco-P A-4. BAUD RATE SETTING th The 9 Dip Switch is used for BAUD RATE setting. DIP SW can be changeable to 2400bps, 9600bps. Factory Default: 2400bps. DIP SW1 9th BAUD RATE OFF 2400 ON 9600 . A-5. 485 TERMINATIONS th 10 Dip Switch is used for 100Ω termination. th Set on 10 Dip Switch only for the last looped camera from the controller. th Even in case of only one camera, set on 10 Dip Switch of the cameras. 26 TROUBLESHOOTING If you have trouble in operating in your camera, refer to the following. PROBLEM SOLUTION No operation Check if the power supply is DC12V or AC24V. Check if RS-485 communication cable is connected correctly. Check camera ID setting. Check the termination. No picture Check if all the cables are connected correctly. Check if the monitor is adjusted correctly. Check if video signal line is cut. Dark screen Adjust the monitor status. Abnormal camera Operation status Check if voltage level is out of the specification. Check the termination. Screen not clear Check if there is dust on the lens. Adjust the monitor status. If excessive light is seen on a screen, change the camera angle or location. Adjust the lens focus again. 27 SPECIFICATIONS MODEL PAN /TILT HTSD12X Pan Rotation Angle Manual Pan Speed Preset Tilt Rotation Angle Manual Tilt Speed Preset System Accuracy Presets Group Tour FUNCTIONS POWER OTHERS Auto scan Pattern Privacy Zone Sector Password Protection Alarm Input Alarm Actions Auto Flip OSD Menu Communication Protocol Power Consumption Power Supply Construction Dimensions Weight Motor Type Micro Steps Storage Temperature Operating Temperature Image Sensor 1/4" Sony Super-HAD CCD Total NTSC Image PAL Pixels Number Of NTSC Effective PAL Pixels Horizontal/Vertical resolution Lens 811(H) * 508(V) 795(H) * 596(V) 768(H) * 494(V) 752(H) * 582(V) More Than 560(Color) / 600(BW) TV Lines Optical 12x Optical Zoom(f=3.6 to 44.3mm, F1.6(Wide)/F2.0(Tele) Digital 12x (144x with optical) Day & Night (ICR) CAMERA MODULE 360˚ Endless 1˚ ~ 240˚/sec Max 240˚ /sec 0˚ ~ 90˚ 1˚ ~ 240˚/sec Max 240˚ /sec 0.02˚ 164 positions with a 16-character label available for each position with different speed steps Max. 8 Programmable group tours (each one consisting of up to 60 preset steps with different steps) Programmable Auto scan 8 Programmable Patterns (total 400 seconds) 4 privacy zones 8 selectable Sectors with 16 characters Yes 4 alarms OFF/NC/NO (with various programmable states) Activate preset, Group scanning or Patterns ON / OFF Multiple Languages on screen RS-485 Pelco D/P 12VDC 800mA / 24VAC 400mA 12VDC or 24VAC(Dual Voltage) die-casting , Anti-vandal dome cover 167.0φ (D) * 167.0mm(H) 1.5 kg Stepper Motor 1/4 Step -40F~ 140F -14F ~ 120F Min. Shooting Distance Digital Slow Shutter Color mode Night mode Luminance S/N Ratio Min. illumination (F1.6/Wide) Video Output Auto/ Day/ Night 0.2m(Wide)/0.8m(Tele) 2/4//6/8/12/16/24/32/48/64/96/128/256/ OFF 0.008 Lux (50IRE, Sens x256) 0.0008 Lux (50IRE, Sens x256) More than 52dB VBS:1.0Vp-p/75 Ohm BLC ON / OFF Flickerless ON / OFF WHITE BALANCE ATW1/ATW2/INDOOR/OUTDOOR 28 DIMENSIONS 29 30 31 Speco Technologies is constantly developing product improvements. We reserve the right to modify product design and specifications without notice and without incurring any obligation. (Rev. 130328) 32
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement