Split Air Conditioner

Split Air Conditioner
Split Air Conditioner
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully .
AWI/O-25HPDC1C
AWI/O-35HPDC1C
AWI/O-53HPDC1C
AWI/O-70HPDC1C
Operation Notices
Content
Precautions............................................................................................................1
Parts Name............................................................................................................2
Screen Operation Guide
Buttons on remote controller .................................................................................3
Introduction for buttons on remote controller .........................................................4
Function introduction for combination buttons .......................................................8
Operation guide .....................................................................................................9
Replacement of batteries in remote controller .......................................................9
Emergency operation .......................................................................................... 10
Maintenance
Clean and Maintenance....................................................................................... 10
Malfunction
Malfunction analysis ............................................................................................13
Installation Notice
Installation dimension diagram ............................................................................17
Tools for installation .............................................................................................18
Selection of installation location ..........................................................................18
Requirements for electric connection ..................................................................19
Installation
Installation of indoor unit......................................................................................20
Installation of outdoor unit ...................................................................................25
Vacuum pumping .................................................................................................28
Leakage detection ...............................................................................................28
Check after installation ........................................................................................29
Test and operation
Test operation ......................................................................................................29
Attachment
Install snow guard (Optional)...............................................................................30
.........................................................................31
Pipe expanding method .......................................................................................33
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
R410A(R32/125: 50/50): 1975
Precautions
Warning
● Do not connect air conditioner to multi-purpose socket.Otherwise, it may
● Do disconnect power supply when cleaning air conditioner. Otherwise, it may
cause electric shock.
● Do not spray water on indoor unit. It may cause electric shock or malfunction.
● Do not spill water on the remote controller, otherwise the remote controller
may be broken.
● Do not repair air conditioner by yourself. It may cause electric shock or
damage. Please contact dealer when you need to repair air conditioner.
● Do not block air outlet or air inlet. It may cause malfunction.
person can perform the work. Otherwise, it may cause personal injury or
damage.
● Do not step on top panel of outdoor unit, or put heavy objects. It may cause
damage or personal injury.
personal injury or damage.
● Air Conditioner should be properly grounded. Incorrect grounding may cause
electricshock.
● Do install the circuit break. If not, it may cause malfunction.
Otherwise, it may cause personal injury or damage.
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(℃ )
32/23
27/-
Outdoor side DB/WB(℃ )
43/24/18
● The operating temperature range (outdoor temperature) is -15℃ ~ 43℃ (winter
heating option required).
1
Parts Name
Indoor Unit
panel
air inlet
air outlet
horizontal louver
display
temp. indicator
(Note: This dispaly is not available for some models.)
cooling indicator
drying indicator
FAN AUTO
OPER
AIR HEALTH X-FAN
HUMIDITY
FILTER
TURBO
heating indicator
aux.button
power indicator
receiver window
(Display content or position may be different from above
graphics, please refer to actual products)
Outdoor Unit
HOUR
ON/OFF
ON/OFF
MODE
FAN
X-FAN
TEMP
TIMER
TURBO
SLEEP
LIGHT
remote controller
air inlet
handle
air outlet
Notice:
Actual product may be different from above graphics, please refer to actual
products.
2
Buttons on remote controller
FAN
AUTO
OPER
AIR HEALTH X-FAN
HUMIDITY
FILTER
TURBO
HOUR
ON/OFF
2
1
3
ON/OFF
MODE
5
4
7
FAN
6
8
9
11
TEMP
TIMER
TURBO
SLEEP
LIGHT
ON/OFF button
2
MODE button
3
+/- button
4
FAN button
5
button
6
button
7
HEALTH SAVE button
8
X-FAN button
9
TEMP button
10 TIMER button
10
X-FAN
1
11 TURBO button
12 SLEEP button
13
13 LIGHT button
12
Introduction for icons on display screen
air mode
Operation mode
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
set fan speed
FAN
AUTO
AIR HEALTH X-FAN
HUMIDITY
FILTER
send signal
health mode
X-fan
set temperature
TURBO
HOUR
ON/OFF
Child Lock
Sleep mode
Temp. display type
:Set temp.
:Indoor ambient temp.
:Outdoor ambient temp.
OPER
turbo mode
TIMER ON/TIMER OFF
set time
left & right swing
light
3
Up & down swing
Introduction for buttons on remote controller
Note:
● After putting through power, air conditioner will give out a sound and operation
indicator " " is ON (red indicator). You can operate the air conditioner through
the remote controller.
● At ON status, after each pressing button on remote controller, the signal icon " "
indicates the signal has been sent to air conditioner.
● At OFF status, display screen on remote controller displays set temperature.
At on status, display screen on remote controller displays the corresponding startup
function’s icon.
1
ON/OFF button
Press this button can turn on or turn off the air conditioner. After turning on the unit,
operation indicator " " on indoor unit is ON (green indicator. Color may be different for different models)and indoor unit gives out a sound.
2
MODE button
Press this button can select your required operation mode.
AUTO
COOL
DRY
FAN
HEAT
● After selecting auto mode, air conditioner will operate automatically according to
ambient temperature. Set temperature can’t be adjusted and also can’t be displayed. Press "FAN" button can adjust fan speed. Press " " button and " " button
can adjust swing angle.
● After selecting cool mode, air conditioner operates under cool mode. Cool indicator
" " on indoor unit is ON. You can press "+" or "-" button to adjust set temperature.
Press "FAN" button can adjust fan speed. Press " " button and " " button can
adjust swing angle.
● After selecting dry mode, air conditioner operates under dry mode at low speed.
Dry indicator " " on indoor unit is ON. Under dry mode, fan speed can’t be adjusted. Press " " button and " " button to adjust swing angle.
● After selecting fan mode, air conditioner operates only under fan mode, All mode
indicators on indoor unit is OFF. Operation indicator is ON. Press "FAN" button can
adjust fan speed. Press " " button and " " button to adjust swing angle.
● After selecting heat mode, air conditioner operates under heat mode. Heat indicator
" " on indoor unit is ON. You can press "+" or "-" button to adjust set temperature.
Press "FAN" button to adjust fan speed. Press " " button and " " button to adjust
swing angle. (Cooling only unit can’t receive the signal for heating mode.)
4
Introduction for buttons on remote controller
Note:
For preventing cold wind, after starting up heating mode, indoor fan will blow fan
afterdelaying 1-5min. (Details time is decided by indoor ambient temperature)
Temperature setting range on remote controller: 16℃ -30℃ . Fan speed setting
range: auto, low speed, medium speed and high speed.
3
"+" or "-" button
● After each pressing of "+" or "-" button, it can increase or decrease set temperature 1℃ . Hold "+" or "-" button, 2s later, set temperature on remote controller
will change quickly. After reaching to your required time, loosen the button.
Temperature indicator on indoor unit will also change accordingly. (Temperature
can’t be adjusted under auto mode)
● Under TIMER ON, TIMER OFF or Clock setting, you can press "+"or "-" button to
adjust time. (Refer to TIMER button for details)
4
FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), low(
(
), high(
).
),medium
Auto
Note:
● Under AUTO Speed,IDU fan motor will adjust the fan speed (high, medium or low
speed) according to ambient temperature.
● Fan speed under dry mode is low speed.
5
button
Press this button can select up&down swing. Swing angle can be selected in sequence as below:
no display
(horizontal louvers stops
at current position)
When selecting " " with remote controller, it’s auto swing. Horizontal louver of air
conditioner will swing up&down automatically at the maximum angle.
When selecting " 、 、 、 、
swing. Horizontal louver of air conditioner will stop at that position as shown by the
icon to swing.
5
Introduction for buttons on remote controller
button
6
Press this button can select left&right swing. Swing angle can be selected
circularly in sequence as below:
no display
(horizontal louvers stops
at current position)
(swing angle is displayed dynamically)
● When selecting " " with remote controller, it’s auto swing. Horizontal louver of
air conditioner will swing left&right automatically at the maximum angle.
● When selecting " 、 、 、 、 "
position swing. Horizontal louver of air conditioner will stop at that position as
shown by the icon to swing.
● When selecting "
", it’s the circulating swing. Horizontal louver of
(swing angle is displayed dynamically)
air conditioner will swing circularly according to the angle as shown by the icon.
7
HEALTH SAVE button
HEALTH FUNCTION:
After pressing HEALTH button, remote controller will switch circularly as below:
"HEALTH"→"AIR"→"AIR HEALTH"→"no display"
● When selecting "HEALTH" by remote controller, HEALTH function will be started up.
● When selecting "AIR" by remote controller, AIR function will be started up.
● When selecting "AIT HEALTH", AIR and HEALTH function will be started up.
● When there’s no display on remote controller, AIR and HEALTH function will be
turned off.
● AIR function is applicable for some models.
SAVE function:
Under cool mode, press SAVE button and the unit will operate under SAVE mode.
Dual-8nixie tube on remote controller displays "SE". Air conditioner will operate at
auto speed. Set temperature can’t be adjusted. Press SAVE button again to exit
SAVE mode. Air conditioner turn back to original set speed and set temperature.
● This function is applicable to partial of models.
8
X-FAN button
After pressing this button under cooling or dry mode, remote controller displays the
character of "X-FAN" and X-FAN function is started up. Press this button again to
cancel X-FAN function. The character of "X-FAN" will disappear.
Note:
● After starting up X-FAN function, when turning off the unit, indoor fan will continue
6
Introduction for buttons on remote controller
to operate for a while at low speed to dry the residual water inside the indoor unit.
● When the unit operates under X-FAN mode, press "X-FAN" button can turn off
X-FAN function. Indoor fan stops operation immediately.
9
TEMP button
Press this button can see indoor set temperature, indoor ambient temperature or
outdoor ambient temperature on indoor unit’s display. Temperature is set circularly
by remote controller as below:
no display
● When selecting " " by remote controller or no display, temperature indicator on
indoor unit displays set temperature.
● When selecting " " by remote controller, temperature indicator on indoor unit
displays indoor ambient temperature.
● When selecting "
" by remote controller, temperature indicator on indoor unit
displays outdoor ambient temperature.
Note:
● Outdoor ambient temperature display may can’t be selected for some models.
When indoor unit receives "
" signal, it displays indoor set temperature.
● Only for the model whose indoor unit has dual-8 display.
10
TIMER button
● At ON status, press this button once can set TIMER OFF. The character of HOUR
TIMER
ON. After each pressing of "+" or "-" button, time will increase or decrease half an
hour. When holding "+" or "-" button, 2s later, the time will change quickly until to
Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status.
● At OFF status, press this button once can set TIMER ON. Please refer to TIMER
off for detailed operation.
Cancel TIMER ON: Press "TIMER" button again under TIMER ON status.
Note:
● Time setting range: 0.5-24 hours.
● Time interval between two operations can’t exceed 5s. Otherwise, remote
controller will exit the setting status automatically.
7
Introduction for buttons on remote controller
11 TURBO button
When pressing this button under cooling or heating mode, air conditioner will enter
into quick cooling or quick heating mode. The character of "TURBO" is displayed
on remote controller. Press this button again to exit turbo function and the character
of "TURBO" will be disappeared on remote controller.
12
SLEEP button
Press this button under cooling, heating mode can start up sleep function.
" " icon will be displayed on remote controller. Press this button again to cancel
sleep function. " "icon on remote controller will be displayed.
13
LIGHT button
Press this button can turn off the light for indoor unit’s display. " " icon on remote
controller will disappear. Press this button again to turn on the light for indoor unit’s
display. " " icon on remote controller will be displayed.
Function introduction for combination buttons
Child lock function
Press "+" and "-" buttons simultaneously can turn on or turn off child lock function.
When child lock function is started up, " " icon will be displayed on remote
controller won’t send signal.
Switchover function for temperature display
After turning off the unit by remote controller, press "-" button and "MODE" button
simultaneously to switch between ℃ and °F .
8
Operation guide
1. After putting through the power, press " ON/OFF " button on remote controller to
turn on the air conditioner.
2. Press " MODE " button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4. Press " FAN " button to set your required fan speed: auto, low, medium and
high speed.
5. Press "
" and "
" button to select fan blowing angle.
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
signal sender
battery
reinstall
remove
Cover of battery box
Note:
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
or wireless telephone; remote controller should be close to indoor unit during
operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
9
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
Clean and Maintenance
Note:
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
Note:
● Do not remove the panel when cleaning it.
10
Clean and Maintenance
Clean filter
1
2
Open panel
3
Pull out the panel to a certain
angle as shown in the fig.
Clean filter
● Use dust catcher or water to
clean the filter.
● When the filter is very dirty, use
the water (below 45℃ ) to clean
it, and then put it in a shady
and cool place to dry.
Remove filter
Remove the filter as indicated in the fig.
4
Install filter
Install the filter and then close the
panel cover tightly.
Note:
■ The filter should be cleaned every three months. If there is much dust in the
operation environment, clean frequency can be increased.
■ After removing the filter, do not touch fins to avoid injury.
■ Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
11
Clean and Maintenance
Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether circuit break, plug and socket are in good condition.
3. Check whether filter is clean.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
Checking after use-season
1. Disconnect power supply.
2. Clean filter and indoor unit’s panel.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
12
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualified professionals.
Phenomenon
Check items
Solution
● Whether it's interfered severely ● Pull out the plug. Reinsert
(such as static electricity,stable the plug after about 3min, and
voltage)?
then turn on the unit again.
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
● Whether remote controller is
within the signal receiving
range?
● Signal receiving range is 8m.
● Whether there are obstacles?
● Remove obstacles.
● Whether remote controller is
● Select proper angle and point
pointing at the receiving
the remote controller at the rewindow?
ceiving window on indoor unit.
● Is sensitivity of remote contro- ● Check the batteries. If the
ller low; fuzzy display and no
power of batteries is too low,
display?
please replace them.
● Check whether remote cont● No display when operating
roller appears to be damaged.
remote controller?
If yes, replace it.
● Fluorescent lamp in room?
No air
emitted
from
indoor
unit
● Take the remote controller
close to indoor unit.
● Turn off the fluoresent lamp
and then try it again.
● Air inlet or air outlet of indoor
unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set
temperature?
● After reaching to set temperature, indoor unit will stop blowing out air.
● Heating mode is turned on just ● In order to prevent blowing
now?
out cold air, indoor unit will be
started after delaying for several minutes, which is a normal phenomenon.
13
Malfunction analysis
Phenomenon
Air conditioner can’t
operate
Mist is emitted from
indoor unit’s
air outlet
Set temperature can’t
be adjusted
Cooling
(heating)
effect is
not good.
Check items
Solution
● Power failure?
● Wait until power recovery.
● Is plug loose?
● Reinsert the plug.
● Circuit break trips off or fuse is ● Ask professional to replace
circuit break or fuse.
burnt out?
● Wiring has malfunction?
● Ask professional to replace it.
● Unit has restarted immediately
● Wait for 3min, and then turn
after stopping operation?
on the unit again.
● Whether the function setting
for remote controller is
correct?
● Reset the function.
● Indoor temperature and humidity is high?
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
● Unit is operating under auto
mode?
● Temperature can’t be adjusted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
● Your required temperature
exceeds the set temperature
range?
● Set temperature range:
16℃ ~30℃ .
● Voltage is too low?
● Wait until the voltage
resumes normal.
● Filter is dirty?
● Clean the filter.
● Set temperature is in proper
range?
● Adjust temperature to proper
range.
● Door and window are open?
● Close door and window.
14
Malfunction analysis
Phenomenon
Odours are
emitted
Check items
Solution
● Whether there’s odour source, ● Eliminate the odour source.
such as furniture and cigarette,
● Clean the filter.
etc.
Air conditioner ● Whether there’s interference,
such as thunder, wireless
operates normally suddenly devices, etc.
● Disconnect power, put back
power, and then turn on the
unit again.
Outdoor
unit has
vapor
● Heating mode is turned on?
● During defrosting under heating mode, it may generate
vapor, which is a normal
phenomenon.
“Water
flowing”
noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of
refrigerant flowing inside
the unit, which is a normal
phenomenon.
Cracking
noise
● Air conditioner is turned on or
turned off just now?
15
● This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
ation of error code.
Error code
(Note: This dispaly is not
available for some models.)
Indoor display
Above indicator diagram is only
for reference. Please refer to
actual product for the actual
indicator and position.
Below listed error codes are only part error codes. Please refero to error code
list in serive manual for more information.
Error code
Heating indicator ON 10s OFF 0.5s
Troubleshooting
Means defrosting status. It’s the normal phenomenon.
C5 (After energization, the buzzer will give out
Check if the connector jumper contacts properly.
sound when operating remote controller, while
If the PCB is to be replaced, please take off the
the complete unit doesn't work. Indicator is OFF.)
old for the new PCB.
: Malfunction of connector jumper
F1 (Cooling indicator flashes 1 time every 3s):
Malfunction of indoor ambient temperature sensor
Check if indoor room temperature sensor is
connected properly.
F2 (Cooling indicator flashes 2 times every 3s):
Malfunction of evaporator temperature sensor
Check if the evaporator temperature is connected
properly.
Indoor fan block
Check if the terminal of the indoor motor is connected properly.
Replace the fan motor or the indoor board if disabled.
E5 (power indicator flashes 5 times every 3s)
Please contact qualified professionals for service.
E8 (power indicator flashes 8 times every 3s)
Please contact qualified professionals for service.
U8 (power indicator flashes 17 times every 3s)
Please contact qualified professionals for service.
Defrosting or oil return mode
It is normal. The indicating lamp in heat mode will
wink 0.5s and light 10s.
H6 (Power indicator flashes 11 times every 3s):
Note: If there're other error codes, please contact qualified professionals for service.
Warning
■ When below phenomenon occurs, please turn off air conditioner and disconfor service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
16
At least 15cm
Space to the ceiling
Installation dimension diagram
Space to the wall
At least 15cm
At least 15cm
Space to the wall
o
Space to the obstruction
ac
Sp
n
tio
uc
tr
bs
the
At least 250cm
o
et
lea
the
to n
e
ac ctio
Sp stru
st
ob
lea
At cm
30
At least 50cm
At
cm
00
3
st
Drainage pipe
At least 30cm
Space to th
e wall
a
Sp
h
ot
t
ce
eo
At
le
t
as
n
tio
At least 50cm
m
Space to the
obstruction
uc
tr
bs
0c
20
17
Tools for installation
1 Level meter
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
Note:
14 Measuring tape
● Please contact the local agent for installation.
● Don't use unqualified power cord.
Selection of installation location
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local
dealer:
1.The place with strong heat sources,
,
or volatile objects spread in the air.
2.The place with high-frequency
devices (such as welding machine,
medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.The appliance shall not be installed in the laundry.
Outdoor unit
Indoor unit
1. There should be no obstruction near air
inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to
connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5. The location should be able to withstand
the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep way from
fluorescent lamp.
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
18
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
circuit break.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
10. Installation must be performed in accordance with the requirement of NEC
and CEC by authorized personnel only.
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
6. Including an circuit break with suitable capacity, please note the following table.
Circuit break should be included magnet buckle and heating buckle function, it
can protect the circuit-short and overload. (Caution: please do not use the fuse
only for protect the circuit)
Air-conditioner Circuit break capacity
09K、12K
16A
18K、24K
25A
19
Installation of indoor unit
Step one: choosing installation location
rm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
09、12K
Wall
Space
to the
wall
above
150mm
Mark in the middle of it
Left
Φ55
Rear piping hole
18K
Level meter
Wall
Space
to the
wall
above
150mm
Wall
Space
to the
wall
above
150mm
Right
Φ55
Rear piping hole
Mark in the middle of it
Left
Φ55
Rear piping hole
Level meter
Wall
Space
to the
wall
above
150mm
Right
Φ55
Rear piping hole
24K
Wall
Space
to the
wall
above
150mm
Mark in the middle of it
Left
Φ70
Rear piping hole
Level meter
Wall
Space
to the
wall
above
150mm
Right
Φ70
Rear piping hole
2. Open a piping hole with the diameter of Φ55/70 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
20
Installation of indoor unit
Indoor
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are
not provided and should be bought
locally.
outdoor
Φ55/
Φ70
5-10
Step four: outlet pipe
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
left
right
left
rear right
rear left
right
cut off
the hole
Step five: connect the pipe of indoor unit
1. Aim the pipe joint at the corresponding
bellmouth.
pipe joint
union nut
pipe
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
21
Installation of indoor unit
open-end
wrench
union nut
torque wrench
pipe
Hex nut diameter Tightening torque (N.m)
15~20
Φ6
Φ 9.52
30~40
Φ 12
40~55
Φ 16
60~65
Φ 19
70~75
indoor pipe
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and
then wrap it with tape.
insulating pipe
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
2. Bind the joint with tape.
outlet pipe
drain hose
drain hose
outlet
pipe
tape
drain hose
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
● The plastic expansion particles are
not provided.
insulating pipe
Step seven: connect wire of indoor unit
panel
screw
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
wiring cover
22
Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
cable-cross
hole
power connection
wire
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
For some model
with wire clip.
N(1) 2
3
brown yellowgreen
outdoor unit connection
For some model
N(1) 2
3
brown
yellowgreen
outdoor unit connection
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an circuit break must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
23
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor unit
gas
pipe
connection pipe
drain hose
band
indoor and
outdoor power cord
indoor power cord
liquid pipe
band
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
drain hose
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
upper hook
outdoor
sealing gum
lower hook of
wall-mounting frame
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
24
Installation of outdoor unit
Step one: fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
● Take sufficient protective measures when
installing the outdoor unit.
● Make sure the support can withstand at least
four times of the unit weight.
● The outdoor unit should be installed at least
3cm above the floor in order to install drain
joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.
Step two: install drain joint
(Only for cooling and heating
unit)
Step three: fix outdoor unit
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the drain
vent.
drain vent
Drain hose
at least 3cm above the floor
foot holes
foot holes
chassis
outdoor drain joint
25
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right handle of outdoor unit and then remove
the handle.
3. Pretightening the union nut with
hand.
pipe joint
screw
union nut
handle
2. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.
4. Tighten the union nut with torque
wrench by referring to the sheet
below.
torque
Hex nut diameter Tightening
(N.m)
Φ6
15~20
Φ 9.52
30~40
Φ 12
40~55
Φ 16
60~65
Φ 19
70~75
liquid pipe
liquid
valve
gas pipe
gas valve
1. Remove the wire clip; connect the power connection wire and signal control wire
(only for cooling and heating unit) to the wiring terminal according to the color;
3
blue
black
brown
yellowgreen
wire clamp
power connect wire
26
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
● After tighten the screw, pull the power cord slightly to check if it is firm.
● Never cut the power connection wire to prolong or shorten the distance.
Step six: neaten the pipes
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
wall
U-shaped curve
drain hose
Note:
● The through-wal height of drain hose
shouldn't be higher than the outlet
pipe hole of indoor unit.
● Slant the drain hose slightly downwards. The drain hose can't be
curved, raised and fluctuant, etc.
the drain hose
can't raise
upwards.
The drain hose can't be fluctuant
● The water outlet can't be placed
in water in order to drain smoothly.
The drain hose
can't be fluctuant
The water outlet
can't be placed
in water
27
The water
outlet can't be
fluctuant
Vacuum pumping
Use vacuum pump
1. Remove the valve caps on
liquid valve
the liquid valve and gas
piezometer
Lo
Hi
valve and the nut of refrigas valve
gerant charging vent.
valve cap
2. Connect the charging hose refrigerant charging
of piezometer to the refri- vent
gerant charging vent of gas nut of refrigerant
valve and then connect the charging vent
other charging hose to the
vacuum pump
vacuum pump.
3. Open the piezometer cominner hexagon
pletely and operate for
spanner
10-15min to check if the
pressure of piezometer remains in -0.1MPa.
close
4. Close the vacuum pump
open
and maintain this status for
1-2min to check if the pressure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
28
Check after installation
● Check according to the following requirement after finishing installation.
Items to be checked
Possible malfunction
Has the unit been installed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
It may cause insufficient cooling
(heating) capacity.
Is heat insulation of pipeline sufficient?
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
Is the voltage of power supply according to the voltage marked on the
nameplate?
It may cause malfunction or damaging
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the specification?
It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet?
It may cause insufficient cooling
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts.
The gas valve and liquid valve of
connection pipe are open completely?
It may cause insufficient cooling
(heating) capacity.
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃ , the air conditioner can’t
start cooling.
29
Install snow guard (Optional)
In consideration of snow during installation of outdoor units
Note: It is required to equip snow guard and a higher foundation base to
prevent snow from covering air inlet and outlet.
Correct
Incorrect
20cm
Above
The snow guard shall
be wider than the
air conditioner.
seasonal
wind
WALL
seasonal
wind
Snow guard
(Provide at field)
Height of base in consideration of snow
(More than 50cm)
Snow guard
(Install in
windward side)
Windward side
50cm Above
The snow guard shall
be wider than the
air conditioner.
Height of base in consideration of snow
(More than 50cm)
30
More than 50cm
100cm Above
WALL
Configuration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
2.Min. length of connection pipe is 3m.
3.Max. length of connection pipe and max. high difference.
Cooling
capacity
Max length
Max height
of connecdifference
tion pipe
Cooling
capacity
Max length
Max height
of connecdifference
tion pipe
5000Btu/h
(1465W)
15
5
24000Btu/h
(7032W)
25
10
7000Btu/h
(2051W)
15
5
28000Btu/h
(8204W)
30
10
9000Btu/h
(2637W)
15
5
36000Btu/h
(10548W)
30
20
12000Btu/h
(3516W)
20
10
42000Btu/h
(12306W)
30
20
18000Btu/h
(5274W)
25
10
48000Btu/h
(14064W)
30
20
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
● When the length of connection pipe is above 5m, add refrigerant according to
the prolonged length of liquid pipe. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
31
Configuration of connection pipe
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Outdoor unit throttle
Liquid pipe(mm)
Gas pipe(mm)
Cooling only(g/m) Cooling and heating(g/m)
Φ6
Φ9.52 or Φ12
15
20
Φ6 or Φ9.52
Φ16 or Φ19
15
50
Φ12
Φ19 or Φ22.2
30
120
Φ16
Φ25.4 or Φ31.8
60
120
Φ19
_
250
250
Φ22.2
_
350
350
32
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
● Confirm the pipe length according to
the distance of indoor unit and
outdoor unit.
● Cut the required pipe with pipe cutter.
E: Expand the port
● Expand the port with expander.
hard
mold
expander
pipe
pipe
pipe cutter
leaning
uneven
Note:
● "A" is different according to the
diameter, please refer to the sheet
below:
burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
pipe
shaper
downwards
A(mm)
Outer diameter
(mm)
Max
Min
Φ6 - 6.35(1/4")
1.3
0.7
Φ9.52(3/8")
1.6
1.0
Φ12-12.7(1/2")
1.8
1.0
Φ15.8-16(5/8")
2.4
2.2
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
smooth surface
improper expanding
union pipe
leaning
pipe
the length is equal
33
damaged
surface
crack
uneven
thickness
66129914749