york air-conditioning products Residential & VRF 2013 york air-conditioning products Main Features EU Energy Label A Class Heater Cable With the powerful compressor and optimized refrigerant, the SEER can reach EU Energy Label A Class (over 5.1 w/w) or B Class (over 4.6 w/w), greatly reducing the power consumption. Heater cable prevents ice forming on the outdoor unit. Specially indicated in heat pump mode and low ambient temperature conditions. A thermostat regulates the activation of the heater. Auto-Restart Function Turbo Mode When the power supply is interrupted and then restored, the air conditioners automatically restore the previous function setting. Press the Turbo button and the A/C will reach the preset temperature in the shortest time. Two-direction Air Vane Tech Condensate pump With special structural design and microcomputer control, York air conditioners employs a unique bidirectional rotary air vane technology. Made up of a pump and a remote detection unit. The pump absorbs the condensates from the indoor unit and sends it to the draining pipes. Low Ambient Kit Dehumidification The air conditioning unit can operate in cooling mode at low ambient temperature conditions. The kit is suitable for special applications such as computer and power station control rooms where cooling is required even in the winter months. Independent dehumidification function is usually used in rainy days in springtime or damps areas. The unit will alternately operate in cooling mode or fan only mode, which assures strong dehumidification while not lowering room temperature. Sleep Mode Bio Filter With Spleep Mode, the air conditioner’s set temperature will automatically increase (cooling) or decrease (heating) 1°C per hour for the first two hours then hold steady for the next 5 hours after which the air conditioner will stop operation. With the sleep mode function can maintain the most confortable temperature and save energy. Bio Filter consists of a specialized biological enzyme and Eco Filter. The Eco Filter catches very small airborne dust particles and neurilities bacteria, fungi and microbes. Biological enzyme eliminates bacteria by dissolving their cell wall thus eliminating the problem of re-pollution seen in traditional air conditioners. 18/19 Minisplit Systems Main Features Active Carbon Electrostatic Filter Ionizer Active Carbon Filter eliminates certain kinds of odors such as ammonia (NH3) and deactivates harmful chemical gas such as formaldehyde (HCHO). By forming positive positions on the filter surface, Electrostatic Fiber Filter traps small dust particles, smoke and pet fur to prevent allergic reactions. Ionizer brings refreshing air into the home. Anions can stimulate the blood circulation system, improve lung function and effectively prevent respiratory passage illnesses (sutch as asthma and pneumonia). Plasma Filter Valve Protection Cover It protects the service valves and prevents water from dripping. The Plasma Dust Collector can generate an ionization zone. The air is converted to plasma as it passes the high voltage ion generator. 95% of the dust, smoke and pollen particles are attracted to the electrostatic filter. Anti-Rust Cabinet Made from electrolytic zinc steel sheet and antirust coated components. York’s outdoor units are rust free even in coastal regions. Iconography Infrared control Wired control Infrared or Wired control Dry mode Sleep mode Timer Auto Sweep Auto Restart Turbo mode Thin profile Quiet 4 Way Air Flow Floor/ Ceiling Ducted Installation Air Filter Low Ambient Kit york air-conditioning products High Wall High Efficiency Inverter YWHJZH 09 to 24 A complete range from 2.6 kW to 7.0 kW NEW Estimated availability mid March’13 Features Remote controller • DC Inverter compressor • Low noise levels • Ultra high SEER & SCOP, class A++ • Multi louvers design for faster heating • 1W standby • Quiet design with low noise • 8°C heating • 3 sleep modes/curves • Intelligent defrosting • LED display • Overlong distance air flow • Blue crystal fin evaporator • 7 fan speeds with turbo cooling • 3D-airflow with auto horizontal airflow (Left/Right) • Low Ambient Kit • Heater cable • Gold fin condenser • Service valve protection cover • Wireless • I FEEL function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • 5 Fan speeds selection • Quiet/sleep button • Air flow direction setting • LCD display • Turbo mode • Room temperature setting • Lock Button Function Minisplit Systems 20/21 High Wall High Efficiency Inverter YWHJZH 09 to 24 Technical features (preliminary data) Set reference YWHJZH Indoor unit Sizes YWHJXH-09 YWHJXH-12 YWHJXH-18 YWHJXH-24 Outdoor unit Sizes YWHJYH-09 YWHJYH-12 YWHJYH-18 YWHJYH-24 Cooling capacity kW 2.6 (0.7 - 3.8) 3.5 (0.7 - 4.5) 5.3 (0.8 - 6.7) 7.0 (1.3 - 8.7) Heating capacity kW 2.8 (0.7 - 4.0) 3.7 (0.7 - 5.5) 5.3 (1.0 - 7.3) 7.0 (1.2 - 10.0) Compressor Type Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.65 0.88 1.55 2.00 heating kW 0.78 0.95 1.55 2.00 EER 4.05 4.00 3.40 3.52 SEER 7.0 7.2 6.11 6.11 COP 3.56 3.40 3.40 3.52 Power input SCOP Energy Class cooling heating 4.6 4.0 3.81 3.81 A++ A++ A++ A++ A++ A+ A A Indoor airflow m3/h 550 740 950 1 200 Sound pressure Indoor (L/M/H) at 1 m Outdoor dB(A) 25 / 32 / 38 26 / 33 / 39 36 / 42 / 47 39 / 45 / 50 dB(A) 53 53 55 60 H (mm) 292 292 319 326 1 178 Indoor W (mm) 806 966 1 018 D (mm) 209 209 230 264 H (mm) 596 596 700 790 W (mm) 899 899 955 980 D (mm) 378 378 396 427 Indoor unit kg 11 11 15 18 Outdoor unit kg 43 43 50 68 Gas 3/8” 1/2” 1/2” 5/8” Liquid 1/4” 1/4” 1/4” 1/4” 1 700 Dimensions Outdoor Net weight Type of connection Piping Diameter Refrigerant charge Pipe run Flare g 740 1 000 1 160 Length m 15 20 25 25 Height m 10 10 10 10 18 24 Operating limit - cooling mode min./max. -15°C / +48°C Operating limit - heating mode min./max. -20°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Electrostatic dedusting filter Optional Silver ion filter Optional Active carbon filter Optional Manufacturer reserves the rights to change specifications without prior notice. york air-conditioning products High Wall Inverter YEHJZH 09 to 24 A complete range from 2.7 kW to 6.5 kW NEW Features Remote controller • High SEER & SCOP, Class A+ • DC Inverter compressor • Low noise levels • Dry mould proof • Automatic restart • ON/OFF timer • Automatic air sweep • Service valve protection cover • Rustproof casing • Blue fin protection (indoor and outdoor units) • Wireless • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer setting function • Air flow direction setting • LCD display • Turbo mode • Lock button function Minisplit Systems 22/23 High Wall Inverter YEHJZH 09 to 24 Technical features Set reference YEHJZH Indoor unit Sizes YEHJXH-09 YEHJXH-12 YEHJXH-18 YEHJXH-24 Outdoor unit Sizes YEHJYH-09 YEHJYH-12 YEHJYH-18 YEHJYH-24 Cooling capacity kW 2.7 (0.5 - 3.2) 3.5 (0.5 - 3.9) 5.3 (1.3 - 6.6) 6.5 (2.5 - 6.6) Heating capacity kW 2.8 (0.8 - 3.6) 4.0 (0.9 - 4.4) 5.8 (1.1 - 6.8) 7.0 (2.5 - 7.6) Compressor Type Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.87 1.17 1.62 2.18 heating kW 0.90 1.20 1.76 2.22 EER 3.10 3.00 3.25 2.96 SEER 5.6 6.1 5.6 5.1 COP 3.11 3.33 3.30 3.15 3.8 Power input SCOP Energy Class 3.8 3.8 3.8 cooling A+ A++ A+ A heating A A A A Indoor airflow (high speed) m3/h 500 500 780 800 Sound pressure Indoor (L/M/H) at 1 m Outdoor dB(A) 28 / 34 / 39 36 / 39 / 42 35 / 40 / 43 39 / 42 / 47 Indoor Dimensions Outdoor Net weight dB(A) 53 54 55 58 H (mm) 275 275 298 315 W (mm) 845 845 940 1 007 D (mm) 180 180 200 219 H (mm) 540 540 700 790 W (mm) 776 776 955 980 D (mm) 320 320 396 427 Indoor unit kg 10 10 13 14 Outdoor unit kg 28 29 45 60 Gas 3/8” 3/8” 1/2” 5/8” Liquid 1/4” 1/4” 1/4” 1/4” 1 800 Type of connection Piping Diameter Refrigerant charge Pipe run Flare g 700 850 1 300 Length m 15 15 25 25 Height m 10 10 10 10 18 24 Operating limit - cooling mode min./max. +18°C / +50°C Operating limit - heating mode min./max. -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Electrostatic dedusting filter Optional Silver ion filter Optional Cold Plasma filter Optional Active carbon filter Optional Manufacturer reserves the rights to change specifications without prior notice. york air-conditioning products High Wall Inverter YJHJZH 09 to 24 A complete range from 2.6 kW to 6.8 kW NEW Features Remote controller • High SEER & SCOP, Class A • DC Inverter compressor • Low noise levels • Dry mould proof • Automatic restart • Automatic air sweep • Sleep mode function • Self-diagnosis • Easy maintenance • Service valve protection cover • Blue fin protection (indoor and outdoor units) • Wireless • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • On/Off timer • Turbo cool/heat settings • Fan speed selection • Air flow direction setting • LED display • Lock button Minisplit Systems 24/25 High Wall Inverter YJHJZH 09 to 24 Technical features Set reference YJHJZH Indoor unit Sizes YJHJXH-09 YJHJXH-12 YJHJXH-18 YJHJXH-24 Outdoor unit Sizes YJHJYH-09 YJHJYH-12 YJHJYH-18 YJHJYH-24 Cooling capacity kW 2.6 (0.8~3.0) 3.5 (1.0~3.8) 5.1 (1.5~5.5) 6.8 (2.2~7.0) Heating capacity kW 2.8 (1.0~3.3) 3.7 (1.4~4.0) 5.1 (1.6~6.0) 7.0 (2.3~7.3) Compressor Type Rotary Refrigerant R410A Power supply Power input V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.81 1.09 1.59 2.13 heating kW 0.78 1.03 1.42 2.19 3.20 EER 3.21 3.21 3.21 SEER 5.10 5.10 5.10 5.10 COP 3.59 3.59 3.59 3.20 SCOP Energy Class 3.40 3.40 3.40 3.40 cooling A A A A heating A A A A Indoor airflow m3/h 400 450 700 1 000 Sound pressure Indoor (L/M/H) at 1 m Outdoor dB(A) 30 / 35 / 40 31 / 35 / 41 35 / 39 / 42 36 / 39 / 44 dB(A) 49 50 51 55 H (mm) 187 187 191 239 1 046 Indoor W (mm) 795 795 938 D (mm) 265 265 265 299 H (mm) 540 540 640 730 W (mm) 780 780 780 860 D (mm) 245 245 245 308 Indoor unit kg 8.8 8.8 10.5 12 Outdoor unit kg 28 31.5 33 49 Gas 3/8” 3/8” 1/2” 5/8” Liquid 1/4” 1/4” 1/4” 1/4” Dimensions Outdoor Net weight Type of connection Piping Diameter Refrigerant charge Pipe run Flare g 800 1 000 1 200 1 550 Length m 15 15 25 25 Height m 5 5 15 15 18 24 Operating limit - cooling mode min./max. +18°C / +43°C Operating limit - heating mode min./max. -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Electrostatic dedusting filter Optional Silver ion filter Optional Active carbon filter Optional Manufacturer reserves the rights to change specifications without prior notice. york air-conditioning products Multi Inverter Free Indoor Units YJU_YH 14 to 34 A complete range from 4.0 kW to 9.6 kW NEW Indoor units Features Remote controller • High SEER & SCOP, Class A or more • DC inverter compressor • Free match indoor/outdoor • Automatic restart • ON/OFF timer • Automatic air sweep • Valve protection cover • Single general valve design (25K/30K/34K) •B lue fin protection (indoor and outdoor units) • Wireless • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • On/Off timer • Turbo cool/heat settings • Fan speed selection • Air flow direction setting • LED display • Lock button Minisplit Systems 26/27 Multi Inverter Free Indoor Units YJU_YH 14 to 34 Technical features Outdoor units Model Outdoor units YJU_YH Sizes number Indoor units Cooling capacity kW Heating capacity kW Compressor Type (Nb) Refrigerant Location of expansion device Power supply V/Ph/Hz cooling kW Power input heating kW EER SEER COP SCOP cooling Energy Class heating Airflow (outdoor unit) m3/h Sound pressure level dB(A) Dimensions outdoor unit H / W / D mm Net weight outdoor unit kg Type of connection Piping Gas Diameter Liquid Length m Max pipe run * Height m Refrigerant charge g Operating limits min/max YJU2YH014 YJU2YH018 YJU3YH019 2 indoor units 4.0 (1.2 ~ 4.4) 4.1 (1.5 ~ 4.9) 2 indoor units 5.0 (1.3 ~ 5.7) 5.1 (1.9 ~ 6.5) 1.17 1.12 3.40 5.1 3.60 3.4 A A 1 900 62 540 / 780 / 270 38 1.47 1.41 3.40 5.1 3.60 3.4 A A 2 900 63 688 / 810 / 288 43.5 3/8” 1/4” 30 15 1 200 3/8” 1/4” 30 15 1 400 3 indoor units 4 indoor units 5.1 (1.5 ~ 7.0) 7.3 (1.5 ~ 9.0) 6.2 (1.8 ~ 8.1) 8.2 (1.8 ~ 9.5) Rotary Inverter (1) R410A Outdoor unit 230 / 1 / 50 + E 1.39 2.10 1.52 2.06 3.67 3.46 6.2 6.2 4.09 4.00 3.8 3.8 A++ A++ A A 2 000 3 500 52 56 688 / 886 / 289 840 / 948 / 340 51 74 Flare 3/8” 3 x 3/8” + 1 x 1/2” 1/4” 1/4” 50 70 15 15 2 000 3 100 -15°C / +46°C YJU4YH025 * Each indoor unit Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge (each indoor unit) Manufacturer reserves the rights to change specifications without prior notice. YJU4YH030 YJU5YH034 4 indoor units 8.4 (1.5 ~ 9.8) 9.4 (1.8 ~ 10.5) 5 indoor units 9.6 (1.5 ~ 11.0) 10.3 (1.8 ~ 11.5) 2.41 2.43 3.49 6.2 3.85 3.8 A++ A 4 000 56 840 / 948 / 340 76 2.94 2.85 3.25 6.2 3.59 3.8 A++ A 4 000 58 840 / 948 / 340 77 3 x 3/8” + 1 x 1/2” 1/4” 70 15 3 200 4 x 3/8” + 1 x 1/2” 1/4” 80 15 3 400 york air-conditioning products Indoor units technical features • Active carbon electrostatic filter • Automatic air sweep Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping Sizes 07 kW 2.0 kW 2.3 V/Ph/Hz 3 m /h 450 H/M/L dB(A) 36 / 32 / 29 H/W/D mm 265 / 795 / 192 kg 8.8 Type of connection Gas 3/8” Diameter Liquid 1/4” 09 2.6 2.5 450 36 / 32 / 29 265 / 795 / 192 8.8 3/8” 1/4” YJHMXH 12 3.5 3.4 230 / 1 / 50 + E 500 36 / 33 / 30 265 / 795 / 192 8.8 Flare 3/8” 1/4” 18 4.9 5.1 24 6.8 7.1 700 39 / 36 / 33 265 / 938 / 191 10.5 1 100 44 / 41 / 37 299 / 1046 / 234 13 1/2” 1/4” 5/8” 1/4” • Floor/Ceiling • Automatic air sweep Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h H/M/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid YHFMXH 18 5.0 5.5 230 / 1 / 50 + E 800 44 / 41 / 36 665 / 990 / 199 28.3 Flare 1/2” 1/4” 12 3.5 3.9 650 41 / 37 / 33 665 / 990 / 199 26.3 3/8” 1/4” 24 6.3 7.1 800 48 / 45 / 42 665 / 990 / 199 28.3 5/8” 3/8” • Condensate pump included • Automatic air sweep YHKMXH Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions unit Dimensions panel Net weight Piping • Slim size • Air filter included Sizes kW kW V/Ph/Hz m3/h H/M/L dB(A) H/W/D mm H/W/D mm kg Type of connection Gas Diameter Liquid 09 2.6 2.9 620 40 / 36 / 32 260 / 570 / 570 60 / 700 / 700 17 3/8” 1/4” 12 3.5 3.7 18 5.0 5.2 230 / 1 / 50 + E 620 680 40 / 36 / 32 42 / 37 / 35 260 / 570 / 570 260 / 570 / 570 60 / 700 / 700 60 / 700 / 700 18.5 18.5 Flare 3/8” 1/2” 1/4” 1/4” 24 6.5 7.1 1 300 46 / 44 / 39 240 / 840 / 840 60 / 950 / 950 26.8 5/8” 3/8” • Wired control included YHDMXH Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Static pressure Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h Pa H/M/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid 09 2.5 2.9 550 25 37 / 34 / 31 220 / 610 / 483 14 3/8” 1/4” 12 3.5 4.0 18 5.0 5.5 230 / 1 / 50 + E 550 850 25 25 37 / 34 / 31 41 / 35 / 32 220 / 610 / 483 220 / 1 090 / 500 14 23 Flare 3/8” 1/2” 1/4” 1/4” 24 6.8 7.1 1 200 25 45 / 41 / 37 220 / 1 090 / 500 24.5 5/8” 3/8” 28/29 Minisplit Systems Indoor unit combinations YJU2YH014 (2x1) Number connecting units 2x1 7+7 7+9 7+12 9+9 9+12 YJU2YH018 (2x1) Number connecting units 2x1 7+7 7+9 7+12 9+9 9+12 12+12 YJU3YH019 (3x1) Number connecting units 2x1 3x1 7+7 7+9 7+12 7+18 9+9 9+12 9+18 12+12 12+18 7+7+7 7+7+9 7+7+12 7+7+18 7+9+9 7+9+12 7+12+12 9+9+9 9+9+12 9+12+12 YJU4YH025 (4x1) Number connecting units 3x1 2x1 7+18 7+24 9+18 9+24 12+12 12+18 12+24 18+18 18+24 7+7+9 7+7+12 7+7+18 7+7+24 7+9+9 7+9+12 7+9+18 7+12+12 4x1 7+12+18 9+9+9 9+9+12 9+9+18 9+12+12 12+12+12 12+12+18 7+7+7+7 7+7+7+9 7+7+7+12 7+7+7+18 7+7+9+9 7+7+9+12 7+9+9+9 7+9+9+12 9+9+9+9 9+9+9+12 YJU4YH030 (4x1) Number connecting units 3x1 2x1 7+24 9+18 9+24 12+18 12+24 18+18 18+24 24+24 7+7+18 7+7+24 7+9+12 7+9+18 7+9+24 7+12+12 7+12+18 7+12+24 9+9+9 9+9+12 4x1 9+9+18 9+9+24 9+12+12 9+12+18 9+12+24 12+12+12 12+12+18 12+12+24 12+18+18 7+7+7+7 7+7+7+9 7+7+7+12 7+7+7+18 7+7+7+24 7+7+9+9 7+7+9+12 7+7+9+18 7+7+9+24 7+7+12+12 7+7+12+18 7+9+9+9 7+9+9+12 7+9+9+18 7+9+12+12 7+12+12+12 9+9+9+9 9+9+9+12 9+9+12+12 9+9+12+18 9+12+12+12 12+12+12+12 YJU5YH034 (5x1) Number connecting units 2x1 7+18 7+24 9+18 9+24 12+18 12+24 18+18 18+24 24+24 3x1 7+7+12 7+7+18 7+7+24 7+9+9 7+9+12 7+9+18 7+9+24 7+12+12 7+12+18 7+12+24 9+9+9 4x1 9+9+12 9+9+18 9+9+24 9+12+12 9+12+18 9+12+24 12+12+12 12+12+18 12+12+24 12+18+18 18+18+18 7+7+7+7 7+7+7+9 7+7+7+12 7+7+7+18 7+7+7+24 7+7+9+9 7+7+9+12 7+7+9+18 7+7+9+24 7+7+12+12 7+7+12+18 5x1 7+9+9+9 7+9+9+12 7+9+9+18 7+9+12+12 7+12+12+12 9+9+9+9 9+9+9+12 9+9+9+18 9+9+12+12 9+12+12+12 12+12+12+12 7+7+7+7+7 7+7+7+7+9 7+7+7+7+12 7+7+7+9+9 7+7+7+9+12 7+7+7+12+12 7+7+9+9+9 7+7+9+9+12 7+9+9+9+9 9+9+9+9+9 9+9+9+9+12 9+9+9+12+12 york air-conditioning products Floor/Ceiling Inverter YHFJZH 12 to 60 A complete range from 3.6 kW to 14.8 kW NEW Features Remote controller • High SEER & SCOP, Class A or more • Inverter DC compressor and fan motor • Multi-speed fan motor • Washable filter • Fresh air intake • Convertible - floor or ceiling • Automatic restart • Automatic air sweep • Horizontal and vertical air sweep function • Wide angle air distribution • Slim profile - flush mounting • Low Ambient Kit (sizes 24 to 60) • Electrical defrosting • Self diagnosis • Blue fin protection (indoor and outdoor units) • Wireless • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • On/Off timer • Turbo cool/heat settings • Fan speed selection • Air flow direction setting • LED display • Lock button Minisplit Systems 30/31 Floor/Ceiling Inverter YHFJZH 12 to 60 Technical features Set reference YHFJZH Indoor unit Sizes YHFJXH 12 YHFJXH 18 YHFJXH 24 YHFJXH 28 YHFJXH 36 YHFJXH 48 YHFJXH 60 Outdoor unit Sizes YHUJYH 12 YHUJYH 18 YHUJYH 24 YHUJYH 28 YHUJYH 36 YHUJYH 48 YHUJYH 60 Cooling capacity kW 3.6 (0.9~4.5) 5.0 (1.7~5.3) 6.4 (1.8~6.7) 7.8 (1.9~9.2) 9.3 (2.0~10.1) 12.3 (5.5~13.3) 14.8 (3.7~15.1) Heating capacity kW 4.1 (1.0~4.8) 5.6 (1.8~6.0) 7.0 (2.3~7.3) 9.0 (2.0~9.6) 10.6 (2.0~10.8) 13.8 (5.5~15.1) 15.2 (3.7~16.5) Compressor Type 230/1/50 or 400/3/50 400 / 3 / 50 Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 cooling kW 1.12 1.50 2.21 2.47 2.98 3.97 5.02 heating kW 1.10 1.51 2.14 2.48 2.91 4.08 4.62 EER 3.22 3.33 2.89 3.15 3.11 3.09 2.95 SEER 5.3 5.6 5.2 5.7 5.6 - - COP 3.73 3.71 3.27 3.63 3.62 3.38 3.28 Power input 3.8 3.6 3.6 3.8 3.8 - - cooling A A+ A A+ A+ - - heating A A A A A - - m3/h 650 / 550 / 450 800 / 720 / 650 850 / 800 / 720 1630 / 1537 / 1375 1630 / 1537 / 1375 Indoor (H/M/L) dB(A) 41 / 37 / 33 44 / 41 / 36 48 / 45 / 42 49 / 45 / 43 49 / 45 / 43 53 / 51 / 49 Outdoor dB(A) 46 50 57 58 58 58 59 H (mm) 655 655 655 700 700 700 700 W (mm) 990 990 990 1 298 1 298 1 580 1 580 D (mm) 199 199 199 240 240 240 240 H (mm) 540 688 730 840 840 830 1 250 W (mm) 780 810 860 948 948 1 008 948 D (mm) 245 288 308 340 340 410 340 Indoor unit kg 28.3 28.3 28.3 37 37 54 54 Outdoor unit kg 32 43 49 64 65 82 96 SCOP Energy Class Indoor airflow (H/M/L) Sound pressure at 1 m Indoor Dimensions Outdoor Net weight Type of connection Piping Pipe run Diameter 2000 / 1800 / 1400 2000 / 1800 / 1400 53 / 51 / 49 Flare Gas 3/8” 1/2” 5/8” 5/8” 5/8” 3/4” 3/4” Liquid 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” 3/8” Length m 15 25 25 30 30 50 50 Height m 10 15 15 20 20 30 30 48 60 Operating limits - cooling mode min/max +18°C / +43°C -10°C / +46°C Operating limits - heating mode min/max -15°C / +24°C -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Size 48: Values for single phase models Accessories Sizes 12 18 24 28 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 36 york air-conditioning products Cassette Inverter YHKJZH 12 to 60 A complete range from 3.5 kW to 14.4 kW NEW Features Remote controller • High SEER & SCOP, Class A • Inverter DC compressor and fan motor • Multi-speed fan motor • Washable filter • Fresh air intake • Built-in drain pump • Branch outlet • Automatic restart • Automatic air sweep • Low Ambient Kit (sizes 24 to 60) • Electrical defrosting • Self diagnosis • Blue fin protection (indoor and outdoor units) • Wireless • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • On/Off timer • Turbo cool/heat settings • Fan speed selection • Air flow direction setting • LED display • Lock button Minisplit Systems 32/33 Cassette Inverter YHKJZH 12 to 60 Technical features Set reference YHKJZH Indoor unit Sizes YHKJXH 12 YHKJXH 18 YHKJXH 24 YHKJXH 28 YHKJXH 36 YHKJXH 48 Outdoor unit Sizes YHUJYH 12 YHUJYH 18 YHUJYH 24 YHUJYH 28 YHUJYH 36 YHUJYH 48 YHUJYH 60 Cooling capacity kW 3.5 (0.9~4.5) 4.8 (1.8~5.8) 6.9 (1.8~7.5) 7.8 (2.0~8.7) 9.3 (2.0~10.3) 12.1 (6.0~13.8) 14.4 (3.7~15.1) Heating capacity kW 3.6 (0.9~4.4) 5.1 (2.0~6.1) 7.3 (2.5~8.0) 8.5 (2.5~9.3) 9.4 (2.3~10.8) 12.6 (5.5~14.7) 15.4 (3.7~16.0) Compressor Type Rotary Refrigerant R410A Power supply Power input YHKJXH 60 V/Ph/Hz 230/1/50 or 400/3/50 400 / 3 / 50 Cooling kW 1.08 1.49 2.22 2.59 3.00 4.11 5.12 Heating kW 1.00 1.58 2.01 2.53 2.78 4.07 5.11 3.24 3.22 3.10 3.01 3.10 2.94 2.81 EER 230 / 1 / 50 SEER 5.1 5.1 5.2 5.2 5.3 - - COP 3.62 3.22 3.63 3.36 3.38 3.10 3.01 3.6 3.4 3.6 3.4 3.6 - - A A A A A - - A - - SCOP Energy Class Cooling Heating A A A A m3/h 620/520/450 700/620/500 1300/1100/870 1300/1100/870 Indoor (H/M/L) dB(A) 40 / 36 / 32 42 / 37 / 35 46 / 44 / 39 48 / 46 / 44 49 / 47 / 44 49 / 47 / 44 Outdoor dB(A) 46 50 57 58 58 58 59 H (mm) 260 260 240 240 290 290 280 W (mm) 570 570 840 840 840 840 1 230 D (mm) 570 570 840 840 840 840 840 H (mm) 540 688 730 840 840 830 1 250 W (mm) 780 810 860 948 948 1 008 948 D (mm) 245 288 308 340 340 410 340 Indoor airflow (H/M/L) Sound pressure at 1 m Indoor Dimensions Outdoor Net weight Pipe run 49 / 44 / 42 Panel H / W / D mm 60 / 700 / 700 60 / 700 / 700 60 / 950 / 950 60 / 950 / 950 60 / 950 / 950 60 / 950 / 950 80 / 950 / 1 340 Indoor unit kg 18.5 18.5 26.8 26.8 38 38 46 Outdoor unit kg 32 43 49 64 65 82 96 Panel kg 2.8 2.8 4.2 4.2 4.2 4.2 8.4 Gas 3/8” 1/2” 5/8” 5/8” 5/8” 3/4” 3/4” Liquid 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” 3/8” Type of connection Piping 1600/1450/1300 1600/1450/1300 1980/1750/1500 Diameter Flare Length m 15 25 25 30 30 50 50 Height m 10 15 15 20 20 30 30 48 60 Operating limits - cooling mode min/max 18°C / +43°C -10°C / +46°C Operating limits - heating mode min/max -15°C / +24°C -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Size 48: values for single phase models Accessories Sizes 12 18 24 28 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 36 york air-conditioning products Blower Inverter YHDJZH 12 to 60 A complete range from 3.5 kW to 15.2 kW NEW Features Wired control • High SEER & SCOP, Class A or more • Inverter DC compressor and fan motor • Washable filter • Automatic restart • Condensate pump optional • Quiet operation • Wired control • Low Ambient Kit (sizes 24 to 60) • Electrical defrosting • Self diagnosis • Blue fin protection (indoor and outdoor units) • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer • LCD display • 3-minute protection • Weekly timer Minisplit Systems 34/35 Blower Inverter YHDJZH 12 to 60 Technical features Model LOW STATIC PRESSURE MEDIUM STATIC PRESSURE Set reference HIGH STATIC PRESSURE YHDJZH Indoor unit Sizes YHDJXH 12 YHDJXH 18 YHDJXH 24 YHDJXH 24 YHDJXH 28 YHDJXH 36 YHDJXH 48 YHDJXH 48 YHDJXH 60 Outdoor unit Sizes YHUJYH 12 YHUJYH 18 YHUJYH 24 YHUJYH 24 YHUJYH 28 YHUJYH 36 YHUJYH 48 YHUJYH 48 YHUJYH 60 Cooling capacity kW 3.5 (0.8~4.1) 5.0 (1.7~5.5) 7.1 (1.8~7.5) 7.1 (1.8~7.5) 8.1 (1.9~9.0) 9.4 (2.0~10.1) 12.2 (5.6~13.6) 12.4 (5.6~13.6) 15.2 (3.7~15.8) Heating capacity kW 4.0 (0.9~4.4) 5.4 (1.8~6.0) 7.2 (2.8~7.6) 7.3 (2.3~7.8) 9.1 (2.0~9.6) 10.2 (2.0~11.0) 13.6 (5.6~15.4) 13.7 (5.6~15.4) 16.0 (3.7~17.0) Compressor Type Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 230/1/50 or 400/3/50 400 / 3 / 50 cooling kW 1.08 1.55 2.18 2.16 2.69 3.17 4.34 4.31 5.37 heating kW 1.16 1.49 1.98 2.00 2.46 2.88 4.24 3.80 4.68 EER 3.24 3.22 3.25 3.29 3.01 2.96 2.81 2.87 2.83 SEER 5.3 5.6 5.6 5.2 5.2 5.1 - - - COP 3.45 3.61 3.63 3.65 3.69 3.53 3.21 3.61 3.42 Power input 3.8 3.8 3.8 3.8 3.5 3.4 - - - cooling A A+ A+ A A A - - - heating A A A A A A - - - 500 900 1 100 1 050 2 090 2 090 2 090 2 580 2 580 SCOP Energy Class Indoor airflow m3/h External static pressure Sound pressure at 1 m 0 / 30 0 / 30 0 / 30 0 / 50 50 / 100 50 / 100 50 / 100 50 / 150 50 / 150 33 / 28 / 23 36 / 30 / 26 39 / 32 / 29 44 / 42 / 39 48 / 46 / 42 48 / 46 / 42 49 / 47 / 43 50 / 46 / 42 50 / 46 / 42 dB(A) Outdoor dB(A) 46 50 57 57 58 58 58 58 59 H (mm) 185 185 185 270 270 270 270 360 360 W (mm) 850 1 170 1 170 950 1 135 1 135 1 135 1 197 1 197 D (mm) 420 420 420 650 742 742 742 830 830 H (mm) 540 688 730 730 840 840 830 830 1 250 W (mm) 780 810 860 860 948 948 1 008 1 008 948 D (mm) 245 288 308 308 340 340 410 410 340 Indoor Dimensions Outdoor Net weight Pa Indoor (H/M/L) Indoor unit kg 17 25 27 37 52 52 52 54 54 Outdoor unit kg 32 43 49 49 64 65 82 82 96 Type of connection Piping Pipe run Diameter Flare Gas 3/8” 1/2” 5/8” 5/8” 5/8” 5/8” 3/4” 3/4” 3/4” Liquid 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Length m 15 25 25 25 30 30 50 50 50 Height m 10 15 15 15 20 20 30 30 30 48 48 60 Operating limits - cooling mode min/max 18°C / +43°C -10°C / +46°C Operating limits - heating mode min/max -15°C / +24°C -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Sizes 48: Values for single phase models Accessories Sizes 12 18 24 24 28 Condensate pump Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 36 york air-conditioning products 38/39 Minisplit On/Off Systems high wall units multisplits cassette, floor/ceiling & blower units window units york air-conditioning products High Wall On/Off EAHC 09 to 24 FS-R A complete range from 2.5 kW to 6.2 kW Features Remote controller • Low noise levels • Class A • Automatic restart • ON/OFF timer • Automatic air sweep • Service valve protection cover • Rustproof casing • Blue fin protection (indoor and outdoor units) • Wireless • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer setting function • Air flow direction setting • LCD display Minisplit Systems 40/41 High Wall On/Off EAHC 09 to 24 FS-R Technical features Set reference EAHC FS-R Indoor unit Sizes EAKC 09 FS-R EAKC 12 FS-R EAKC 18 FS-R EAKC 24 FS-R Outdoor unit Sizes EAJC 09 FS-R EAJC 12 FS-R EAJC 18 FS-R EAJC 24 FS-R Cooling capacity kW 2.5 3.1 4.6 6.2 Heating capacity kW 2.7 3.4 5.0 6.5 Compressor Type Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.80 1.00 1.50 1.90 heating kW 0.82 0.99 1.35 1.90 EER 3.21 3.21 3.21 3.22 COP 3.41 3.41 3.63 3.41 cooling A A A A heating B B A B m3/h 350 400 750 780 Indoor (L/M/H) dB(A) 32 / 35 / 37 32 / 35 / 38 37 / 41 / 45 38 / 41 / 45 Outdoor dB(A) 50 52 55 56 H (mm) 255 265 298 298 W (mm) 730 790 940 940 D (mm) 174 170 200 200 H (mm) 540 540 540 680 W (mm) 776 798 848 913 D (mm) 320 355 360 428 Power input Energy Class Indoor airflow (high speed) Sound pressure at 1 m Indoor Dimensions Outdoor Net weight Indoor unit kg 8 9 13 13 Outdoor unit kg 31 35 40 46 Gas 3/8” 1/2” 1/2” 1/2” Liquid 1/4” 1/4” 1/4” 1/4” 1 450 Type of connection Piping Diameter Refrigerant charge Pipe run Flare g 660 840 1 150 Length m 15 20 25 25 Height m 10 10 10 10 18 24 Operating limit - cooling mode min./max. +18°C / +46°C Operating limit - heating mode min./max. -7°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Electrostatic dedusting filter Optional Silver ion filter Optional Active carbon filter Optional Non available for EC countries. Manufacturer reserves the rights to change specifications without prior notice. york air-conditioning products Information for minisplit installation Model Size High wall Inverter YWHJZH R410A 09 12 18 24 High wall Inverter YJHJZH R410A 09 12 18 24 High wall Inverter YEHJZH R410A 09 12 18 24 High wall On-Off YVHFZH R410A 09 12 18 24 High wall On-Off EAHC-FS-R R410A 09 12 18 24 High wall Multisplit EMHC R410A 18 21 27 30 Power supply Power supply cable size (mm2) Interconnection cables (number of cables and sizes) (mm2) Indoor 3 x 2.5 4 x 2.5 Maximum pipe run (m) Maximum height (m) YWHJZH 15 20 Outdoor 25 Indoor 15 Piping diameter Liquid - gas Outdoor unit charged for a piping length of (m) 1/4 - 3/8” 10 Extra refrigerant charge for every meter (gr) 20 5 1/4 - 5/8” 50 YJHJZH 3 x 2.5 5 1/4 - 3/8” 15 1/4 - 1/2” 1/4 - 5/8” 4 x 2.5 Outdoor 25 Indoor 15 20 5 50 YEHJZH 3 x 2.5 1/4 - 3/8” 4 x 2.5 Outdoor 10 25 1/4 - 1/2” 1/4 - 5/8” 5 20 50 YVHFZH Indoor Outdoor Indoor Outdoor 3 x 2.5 3x4 3 x 2.5 3x4 5 x 2.5 20 6x4 30 5 x 2.5 EAHC-FS-R 15 20 6x4 10 1/4 - 3/8” 1/4 - 1/2” 15 16 3/8” - 5/8” 4 50 1/4 - 3/8” 10 25 1/4 - 1/2” 30 30 5 50 EMHC Outdoor 3x4 6 x 2.5 15 * 7 1/4 -3/8” 5* 30 15 * 1/4-3/8” ** 5* 40 YJU_YH Multisplit Inverter YJU_YH R410A Floor/Ceiling Inverter YHFJZH Cassette Inverter YHKJZH Blower Inverter YHDJZH R410A 14 18 19 25 30 34 12 18 24 28 36 30 * Outdoor 3x4 4 x 1.5 50 * 70 * 80 * YHFJZH / YHKJZH / YHDJZH 15 10 Ind: 3 x 1.5 Out: 3 x 2.5 Outdoor & Indoor 48 60 Ind: 3 x 2.5 Out: 3 x 4 4 x 0.25 Ind: 3 x 2.5 Out: 3 x 6 Ind: 3 x 2.5 Out: 5 x 4 25 15 30 20 50 30 1/4 - 3/8” 1/4 - 1/2” 3/8 - 5/8” 30 60 5 120 3/8 - 1/4” EOHC / EKHC / EUHC Floor/Ceiling EOHC Cassette EKHC Blower EUHC R410A 09 12 18 24 36 Ind: 3 x 1.5 Out: 3 x 2.5 Outdoor & Indoor 42 48 60 * Each indoor unit ** next indoor unit Confirm about data in the technical documentation. Ind: 3 x 1.5 Out: 3 x 4 Ind: 3 x 1.5 Out: 3 x 6 Ind: 3 x 1.5 Out: 5 x 2.5 20 2 x 0.25 15 30 50 1/4 - 1/2” 3/8 - 5/8” 30 1/2 - 3/4” 30 5 60 120 Minisplit Systems 52/53 Load calculation Customer Date Telephone Type of installation Project Adress Termical loads PARAMETERS FACTOR CAPACITY not exposed to sunlight m 2 x 50 exposed to sunlight m 2 x 180 = exposed to sunlight with curtains m2 x 135 = exposed to sunlight with awnings m2 x 90 = exposed to sunlight and insulated m2 x 9 = exposed to sunlight non insulated m 2 x 23 = not exposed to sunlight and insulated m 2 x 7 = not exposed to sunlight non insulated m 2 x 12 = m2 x 10 = insulated m2 x 5 = not insulated m 2 x 12 = insulation under the roof m 2 x 10 = not insulation under roof m 2 x 24 = insulated m2 x 7 = not insulated m x 10 = FRESH AIR m3/h x 4,5 = PERSONS INSIDE THE ROOM pers. x 144 = W x 1 = WINDOWS OUTDOOR WALLS INDOOR WALLS * CEILING OR ROOF * FLOOR * 2 WORKING ELECTRICAL EQUIPMENT NEEDED COOLING CAPACITY = W * To not consider if they are next to climatisated area. Important: This is a simplified method to obtain an approximate value of cooling capacity, as long as the climatic conditions are not extreme. Only for cooling calculation. 54/55 VRF Systems yv2v • r410a indoor unit types york air-conditioning products Amazon Standard Ambient VRF System YV2V 010 to 135 Cooling capacities 9 kW to 135 kW NEW VRF System Comfort – Quality • Capacities from 9 to 135 kW • Operating range of nominal power (10% - 130 %) • DC Inverter Scroll Compressor • Low noise levels • High Efficiency. EER up to 4.28 • Modular design • Large indoor unit combinations • Flexible and quickly installation • Cooling and heating • Connection up to 64 indoor units per refrigeration circuit (3 outdoor units) • Complete range in R410A • Reduced space of ground • Is appropriate particularly for existing buildings • Cooling to -5°C to +43°C (outdoor temperature) • Heating to -15°C to +24°C (outdoor temperature) VRF Systems 56/57 Amazon Standard Ambient VRF System YV2V 010 to 135 YV2V DC INVERTER VRF The YV2V (YORK Inverter Air Conditioner) air-conditioner is the system that has variable-frequency compressor and multiple evaporators (indoor units). It is widely used in the world for high efficiency. It provides a broad range of different applications for settings such as offices, hotels and schools. With the advantage of easy installation and simple controlling system and so on, the YV2V system can better meet the demands of the air conditioning market. Flexible indoor unit combinations Each outdoor unit allows to connect up to 16 indoor units. This quantity varies in accordance with the model. The total capacity of the indoor units can vary between 50% and 130% from the total outdoor unit nominal capacity. High Wall Low Static Pressure Duct Medium Static Pressure Duct Floor/Ceiling High Static Pressure Duct Four-way Cassette Console Two-way Cassette Fresh-air indoor units 22.6 - 45.0 kW 9.0 - 18.0 kW 67.8 - 135.0 kW 45.2 - 90.0 kW Manufacturer reserves the rights to change specifications without prior notice. york air-conditioning products Amazon Standard Ambient VRF System YV2V 010 to 045 YV2V Technical features - Mini-VRF outdoor unit Model Cooling capacity YV2VYH010KAR YV2VYH015KAR YV2VYH015KAS 9.0 15.0 15.0 18.0 2.98 3.33 3.06 2.84 20.0 kW EER Heating capacity kW COP YV2VYH018KAS 11.0 17.0 17.0 4.20 3.78 3.95 3.37 Air flow m3/h 3 500 6 500 6 500 6 500 Sound Pressure Level at 1 m dB(A) 58 59 59 60 Power input “cooling” kW 3.02 4.50 4.90 6.33 Power input “heating” kW 2.62 4.50 4.30 5.93 Compressor Type Rotary Rotary Rotary Rotary Height x Width x Length mm 830 x 960 x 380 1 250 x 960 x 380 1 250 x 960 x 380 1 250 x 960 x 380 Weight kg 74 120 120 120 Gas 5/8” 3/4” 3/4” 3/4” Liquid 3/8” 3/8” 3/8” 3/8” Electrical features Power supply 1/N/ 230V 50Hz 3/N/ 400V 50Hz Dimensions and Weight Piping connections Refrigerant charge Type R410A kg 2.6 3.6 4 4 Piping length / Height difference Max. piping length m 50 100 100 100 Max. height difference m 30 30 30 30 4 8 8 9 Max. number of indoor units YV2V Technical features - Single module outdoor unit Model YV2VYH022KAS YV2VYH028KAS YV2VYH033KAS YV2VYH040KAS YV2VYH045KAS 22.6 28.0 33.5 40.0 45.0 4.28 3.80 3.35 3.51 3.36 kW 25.0 31.5 37.5 45.0 50.0 4.24 3.95 3.75 3.88 3.70 Air flow m3/h 11.100 11.100 14.100 14.100 14.100 Sound Pressure Level at 1 m dB(A) 57 57 60 60 60 Power input “cooling” kW 5.27 7.36 10.00 11.40 13.40 Power input “heating” kW 5.89 7.97 10.00 11.60 13.50 Compressor Type Cooling capacity kW EER Heating capacity COP Electrical features Power supply 3/N/ 400V 50Hz DC Inverter Scroll DC Inverter Scroll + Standard Scroll Dimensions and Weight Height x Width x Length mm 1 808 x 990 x 750 1 808 x 990 x 751 1 808 x 1 390 x 750 1 808 x 1 390 x 751 1 808 x 1 390 x 752 Weight kg 240 240 360 360 368 Piping connections Gas 3/4” 7/8” 1” 1” 1 1/8” Liquid 3/8” 3/8” 1/2” 1/2” 1/2” 12 14.5 23 26 Refrigerant charge Type kg R410A 10 11 12 Piping length / Height difference Max. piping length m 150 Max. height difference m 50 Max. number of indoor units 13 16 19 58/59 VRF Systems Amazon Standard Ambient VRF System YV2V 050 to 135 YV2V Technical features - Outdoor units with two module combinations Model YV2VYH050KAS YV2VYH056KAS YV2VYH061KAS YV2VYH068KAS YV2VYH073KAS YV2VYH078KAS YV2VYH085KAS YV2VYH090KAS Module combinations 1x YV2VYH022 1x YV2VYH028 2x YV2VYH028 1x YV2VYH028 1x YV2VYH033 1x YV2VYH028 1x YV2VYH040 1x YV2VYH028 1x YV2VYH045 2x YV2VYH040 1x YV2VYH040 1x YV2VYH045 2x YV2VYH045 Cooling capacity kW 50.6 56.0 61.5 68.0 73.0 78.5 85.0 90.0 Heating capacity kW 56.5 63.0 69.0 76.5 81.5 90.0 95.0 100.0 Noise level at 1 m dB(A) 57 57 60 60 60 57 57 57 Electrical features Power supply 3/N/ 400V 50Hz Power input “cooling” kW 12.63 14.72 17.36 18.76 20.76 22.80 24.80 26.80 Power input “heating” kW 13.86 15.94 17.97 19.57 21.47 23.20 25.10 27.00 Dimensions and Weight Height x Width x Length mm Weight kg 1808 x 1980 x 1501 1808 x 1980 x 1502 1808 x 2380 x 1501 1808 x 2380 x 1502 1808 x 2380 x 1503 1808 x 2780 x 1502 1808 x 2780 x 1503 1808 x 2780 x 1504 480 480 600 600 608 720 728 736 50 53 Piping size between the outdoor unit and the first branch Gas 1 1/8” 1 3/8” Liquid 5/8” 3/4” Refrigerant piping Max. piping length m 150 Max. height difference m 50 Connection between modules (out. groups) Max. number of indoor units HZG - 20A 29 33 36 39 43 46 YV2V Technical features - Outdoor units with three module combinations Model YV2VYH096KAS YV2VYH101KAS YV2VYH106KAS YV2VYH113KAS YV2VYH118KAS YV2VYH123KAS YV2VYH130KAS YV2VYH135KAS Module combinations 2x YV2VYH028 1x YV2VYH040 2x YV2VYH028 1x YV2VYH045 1x YV2VYH028 2x YV2VYH040 1x YV2VYH028 1x YV2VYH040 1x YV2VYH045 1x YV2VYH028 2x YV2VYH045 1x YV2VYH033 2x YV2VYH045 1x YV2VYH040 2x YV2VYH045 3x YV2VYH045 Cooling capacity kW 96.0 101.0 106.5 113.0 118.0 123.5 130.0 135.0 Heating capacity kW 108.0 113.0 121.5 126.5 131.5 137.5 145.0 150.0 Noise level at 1 m dB(A) 60 60 60 60 60 57 57 57 Electrical features Power supply 3/N/ 400V 50Hz Power input “cooling” kW 26.12 28.12 30.16 32.16 34.16 36.80 38.20 40.20 Power input “heating” kW 27.54 29.44 31.17 33.07 34.97 37.00 38.60 40.50 Dimensions and Weight Height x Width x Length mm Weight kg 1808 x 3370 x 2253 1808 x 3370 x 2254 1808 x 3770 x 2253 1808 x 3770 x 2254 1808 x 3770 x 2255 1808 x 4170 x 2254 1808 x 4170 x 2255 1808 x 4170 x 2256 840 848 960 968 976 1 096 1 096 1 104 64 64 64 64 Piping size between the outdoor unit and the first branch Gas 1 3/8” Liquid 3/4” Refrigerant piping Max. piping length m 150 Max. height difference m 50 Connection between modules (out. groups) Max. number of indoor units HZG - 30A 56 59 63 64 york air-conditioning products VRF Technical features indoor units High wall (EXV integrated) Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) V/Ph/Hz A mm kg YVHVXH022 YVHVXH028 YVHVXH036 YVHVXH045 YVHVXH056 YVHVXH071 2.2 2.5 2.8 3.2 3.6 4.0 4.5 5.0 5.6 6.3 7.1 8.0 37 / 33 / 31 37 / 34 / 31 600 800 41 / 36 / 33 41 / 36 / 33 230 / 1 / 50 + N + E 43 / 39 / 34 0.31 265 x 938 x 187 10.9 1/2” 1/4” 48 / 39 / 37 0.41 299 x 1 046 x 239 13 5/8” 3/8” Two Way Cassette Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight HxWxD Panel Weight Gas Piping Liquid YV8VXH028 YV8VXH036 YV8VXH045 YV8VXH056 2.8 3.2 3.6 4.0 4.5 5.0 5.6 6.3 kW kW m3/h dB(A) V/Ph/Hz A mm kg mm kg 840 42 / 37 / 33 44 / 39 / 34 230 / 1 / 50 + N + E 0.5 0.62 280 x 817 x 620 21 8 x 1 055 x 680 7 3/8” 1/4” 1/2” 1/4” Cassette Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight HxWxD Panel Weight Gas Piping Liquid kW kW m3/h dB(A) V/Ph/Hz A mm kg mm kg YVKVXH028 YVKVXH036 YVKVXH045 YVKVXH056 2.8 3.2 700 32 / 30 / 29 3.6 4.0 4.5 5.0 5.6 6.3 650 32 / 30 / 29 33 / 30 / 29 0.47 260 x 570 x 570 17 60 x 700 x 700 2.8 3/8” 1/4” 1/2” 1/4” YVKVXH071 YVKVXH080 YVKVXH090 7.1 8.0 9.0 8.0 9.0 10.0 1 200 34 / 32 / 30 35 / 34 / 31 37 / 35 / 31 37 / 35 / 31 230 / 1 / 50 + N + E 0.67 240 x 840 x 840 30 80 x 950 x 950 6 5/8” 3/8” YVKVXH112 YVKVXH140 11.2 12.5 1 800 37 / 35 / 31 14.0 16.0 44 / 40 / 36 0.76 295 x 840 x 840 38 Convertible console floor/ceiling Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) V/Ph/Hz A mm kg YVFVXH028 YVFVXH036 YVFVXH045 YVFVXH056 YVFVXH071 YVFVXH112 YVFVXH140 2.8 3.2 3.6 4.0 4.5 5.0 800 48 / 46 / 44 5.6 6.3 7.1 8.0 11.2 12.5 14.0 16.0 2 040 50 / 48 / 46 53 / 51 / 49 230 / 1 / 50 + N + E 3/8” 1/4” 0.3 655 x 990 x 199 38.3 1/2” 1/4” 1.8 700 x 1 580 x 240 54 5/8” 3/8” 60/61 VRF Systems VRF Technical features indoor units Console Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid YV5VXH022 YV5VXH028 YV5VXH036 YV5VXH056 2.2 2.5 2.8 3.2 3.6 4.0 520 5.0 6.0 580 48 / 46 / 42 kW kW m3/h dB(A) V/Ph/Hz A mm kg 460 43 / 39 / 36 230 / 1 / 50 + N + E 0.44 640 x 720 x 255 18 1/2” 1/4” Low and Medium Static Pressure Duct Model Low Static Pressure Medium Static Pressure YVDVXH022 YVDVXH028 YVDVXH036 YVDVXH045 YVDVXH056 YVDVXH071 YVEVXH056 YVEVXH071 YVEVXH080 YVEVXH090 YVEVXH112 YVEVXH114 Cooling Heating Air flow Noise level at 1 m H / M / L External static presure Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid Capacity kW kW m3/h dB(A) Pa V/Ph/Hz A mm kg 2.2 2.5 2.8 3.2 400 3.6 4.0 500 35 / 32 / 30 4.5 5.0 850 5.6 6.3 7.1 8.0 5.6 7.1 7.1 8.0 1 200 1 250 39 / 37 / 35 8.0 9.0 9.0 10.0 11.2 12.5 14.0 16.0 2 100 44 / 40 / 36 1 900 43 / 37 / 35 0 ~ 20 50 ~ 96 80 ~ 120 1.1 300 / 1 180 / 743 39 2.2 270 / 1 135 / 742 50 230 / 1 / 50 + N + E 0.27 220 / 610 / 500 15 3/8” 1/4” 0.38 16 25 1/2” 1/4” 0.55 220 / 1 105 / 500 28 5/8” 3/8” 1/2” 1/4” 5/8” 3/8” High Static Pressure Duct Model Cooling Capacity Heating Air flow Noise level at 1 m H / L External static presure Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) Pa V/Ph/Hz A mm kg YVGVXH056 YVGVXH071 YVGVXH080 YVGVXH090 YVGVXH112 YVGVXH140 YVGVXH226 YVGVXH280 5.6 6.3 7.1 8.0 1 500 42 / 40 8.0 9.0 9.0 10.0 1 560 11.2 12.5 1 600 45 / 40 14.0 16.0 2 100 22.6 25.0 28.0 31.6 2.05 360 x 970 x 875 48 1/2” 1/4” Fresh Air Unit Model Cooling Capacity Heating Air flow Noise level at 1 m High speed External static presure Electrical features Power supply HxWxD Dimensions and Weight Weight Gas Piping Liquid 100 230 / 1 / 50 + N + E 2.55 360 x 1 350 x 875 62 5/8” 3/8” 4 050 54 / 49 5.05 360 x 1 610 x 840 92 1” 3/8” Heat Recovery Ventilator YV4VXH140 YV4VXH226 YV4VXH280 kW 14.0 22.6 28.0 kW 8.9 15.2 17.8 m3/h 1 600 2 300 2 800 dB(A) 48 55 Pa 100 V/Ph/Hz 230 / 1 / 50 + N + E mm 360 x 1 350 x 875 360 x 1 750 x 840 kg 62 120 5/8” 1” 3/8” 3/8” Model Air flow External static presure Power supply Dimensions H x W x D and Weight Weight YV6VXH015 YV6VXH026 YV6VXH080 YV6VXH100 m3/h Pa V/Ph/Hz mm kg 150 50 200 800 1 000 60 80 100 230 / 1 / 50 + N + E 276x940x685 276x940x686 387x1227x1115 387x1227x1116 28.7 85.5 york air-conditioning products Controllers & BMS YR-H71 Wireless Controller Elegant and slim design, LCD display, 4 Operation modes (Cool/Dry/Heat/Fan), Timer ON/OFF setting up to 24 Hr., Temperature control range, Fan speed selection. Standard for High Wall and Console, optional for Duct, Cassette and Floor Ceiling. YR-E14 Wired Controller Exclusive design, Big LCD display, 4 Operation modes (Cool/Dry/Heat/Fan), Temperature setting, Timer setting,Fan speed selection, Group controller up to 16 indoor units. Standard for Duct, Cassette and Floor Ceiling, optional for High Wall YCZ-A003 Touch Screen Central Controller Max. 128 indoor units control. Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect. Mode lock function, Blue light background, LCD display screen. HCM-01 Central Controller With Monitor Software Max. 128 indoor units control. Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect. Mode lock function, Blue light background, Software Monitoring on any PC. IGU05 Touch Screen Central Controller Translator Translating protocol between home bus and RS485. Connecting with one outdoor (combination model also regard as one) system. Work with Touch Screen Central Controller IGU02 BacNet/IP Translator IGU07 LonWorks Translator Translating protocol between home bus and RS485. Connecting with one outdoor (combination model also regard as one) system. Work with Central Controller with Monitor Software and BacNet/IP Converter. Translating protocol between home bus and RS485. Connecting with one outdoor (combination model also regard as one) system. Work with LonWorks Converter. IGU07 LonWorks Converter HCM-03 BacNet/IP Converter Max. 32 indoor units control Connect A/C system to BMS by LONWORKS protocol. Max. 72 indoor units control Connect A/C system to BMS by BacNet/IP protocol. 62/63 VRF Systems VRF System - System Diagram Possible to connect to JCI Metasys Piping accessories Model Name Function Application FQG-B335A Indoor mainfold pipe Refrigerant distribution Total indoor units capacity < 33.5 kW FQG-B506A Indoor mainfold pipe Refrigerant distribution 33.5 kW ≤ Total indoor units capacity < 50.6 kW FQG-B730A Indoor mainfold pipe Refrigerant distribution 50.6 kW ≤ Total indoor units capacity < 72 kW FQG-B1350A Indoor mainfold pipe Refrigerant distribution 73 kW ≤ Total indoor units capacity HZG-20A Outdoor branch pipe Refrigerant gathering 2 module combinations HZG-30A Outdoor branch pipe Refrigerant gathering 3 module combinations YORK VRF System A The YORK system with DC Inverter Scroll is working like the VRF principle and offers you economical airconditioning system for projects, which are requiring more capacity than the normal split and multi split solutions. B C The lengths for the connecting tubes between the indoor and outdoor have been prolonged, which brings you more flexible solutions for complex air-conditioning projects. A – Maximum single way pipe length : 150 m. B – Maximum difference in height : 50 m. C–M aximum difference in height between 2 indoor units : 15 m. About Johnson Controls Johnson Controls delivers products, services and solutions that increase energy efficiency and lower operating costs in buildings for more than one million customers. Operating from 500 branch offices in more than 150 countries, the company is a leading provider of equipment, controls and services for heating, ventilating, air-conditioning, refrigeration and security systems. Johnson Controls is involved in more than 500 renewable energy projects including solar, wind and geothermal technologies. Its solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5 billion since 2000. Many of the world’s largest companies rely on Johnson Controls to manage 1.5 billion square feet of their commercial real estate. PUBL-7168 © 2013 Johnson Controls, Inc. www.johnsoncontrols.com E-CAT-MIN-G2013 http://www.johnsoncontrols.co.uk
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement