UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE
Issue Date:
2010-03-02
Page 1 of 13
Report Reference #
E336418-A29-UL
2010-10-22
UL TEST REPORT AND PROCEDURE
CCN:
Complementary CCN:
UL 60950-1, 1st Edition, 2007-10-31 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Power Supplies for Information Technology Equipment Including
Electrical Business Equipment
QQGQ, QQGQ7
Audio/Video Apparatus(AZSQ, AZSQ7)
Product:
Model:
SWITCHING POWER ADAPTER
GT-41069PWWVV-X.X-T3YZ
Rating:
Where WW can be 01-90 for output power, VV can be 12 to 24 for
output voltage, X.X is optional for specifying output voltage deviations
in .1 volt increments, X.X is to be subtracted from rated voltage or
blank, Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can
be 0-9, A-Z or blank for marketing purposes only.
- Input: 100-240 Vac, 1.5 A, 50-60 Hz.
Standard:
Certification Type:
- Output:
12 to 24 Vdc, max. 90 W for GT-41069PWWVV-X.X-T3YZ
For GT-41069P9012-T3, alternate eletrical rating:Input 100-240Vac,
1.5A, 50-60Hz, Output 12Vdc, 4A at Tma 60
Applicant Name and Address:
GLOBTEK (SUZHOU) CO LTD
BLDG 4, #76
JINLING EAST RD
SUZHOU PARK
SUZHOU
JIANGSU 215021 CHINA
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Copyright © 2010
Issue Date:
2010-03-02
Page 2 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any
authorized licensee of UL.
Prepared by:
Vichie Chen
Underwriters Laboratories Inc.
Reviewed by:
Emma Xing
Underwriters Laboratories Inc.
Copyright © 2010
Issue Date:
2010-03-02
Page 3 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
Electronic components mounted on PWB and housed in a plastic enclosure.
Model Differences
Models GT-41069PWWVV-X.X-T3YZ are identical to each other except for transformer, output rating, R43
rating, R46 rating, inlet type and model designation.
Where WW can be 01-90 for output power, VV can be 12 to 24 for output voltage, X.X is optional for
specifying output voltage deviations in .1 volt increments, X.X is to be subtracted from rated voltage or blank,
Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can be 0-9, A-Z or blank for marketing purposes
only.
Technical Considerations

Equipment mobility : movable

Operating condition : continuous

Mains supply tolerance (%) : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Class of equipment : Special Application - Functional Earthing

Mass of equipment (kg) : 0.49 for GT-41069P9012-T Z, GT-41069PWWVV-X.X-T3 Z; 0.46 for GT41069P9012-T3AZ, GT-41069PWWVV-X.X-T3AZ.

Protection against ingress of water : IP X0
Issue Date:
2010-03-02
Page 4 of 13
Report Reference #
E336418-A29-UL
2010-10-22

The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40 degree C and for model For GT-41069P9012-T3,
add Tma 60 degree C under output 12Vdc, 4A.

The means of connection to the mains supply is: Pluggable A, Detachable power cord,

The product is intended for use on the following power systems: TN

The equipment disconnect device is considered to be: Appliance inlet ,

The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): Output for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.X-T3YZ.

The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual

The equipment employs Functional Earthing per 2.6.2. As anticipated by the NOTE for 1.2.4, it does
not conform to one of the common Classes (I, II, or III). The following insulation is provided between
the primary and accessible dead metal parts and circuits: Reinforced , Double
Additional Information
Issue 1, Amendment No. 2:
Add LPS test for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.X-T3YZ.
Markings and instructions
Clause Title
Marking or Instruction Details
Power rating - Ratings
Ratings (voltage, frequency/dc, current)
Power rating - Company Listee's or Recognized company's name, Trade Name, Trademark or File Number
identification
Power rating - Model
Model Number
Fuses - Rating
Rated current and voltage and type located on or adjacent to fuse or fuseholder.
Special Instructions to UL Representative
Inspect the transformer(s) listed in table "Electric Strength Test Special Constructions" per AA1.1– (C):
When the tests are conducted at other location, inspect test record and specification sheet provided by the
component manufacturer. Verify the specification sheet indicates 100% routine test specified in the table be
conducted at the component manufacturer.
Issue Date:
2010-03-02
Page 5 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Production-Line Testing Requirements
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Model
Component
Removable
Parts
Test probe location
All models
T1
--
Primary to Secondary
V
rms
300
0
V dc
Test Time,
s
--
1
Earthing Continuity Test Exemptions - This test is not required for the following models:
Electric Strength Test Exemptions - This test is not required for the following models:
Electric Strength Test Component Exemptions - The following solid-state components may be
disconnected from the remainder of the circuitry during the performance of this test:
Sample and Test Specifics for Follow-Up Tests at UL
Model
N/A
Component
Material
Test
Sample(s)
Test
Specifics
Issue Date:
2010-03-02
Page 6 of 13
Report Reference #
E336418-A29-UL
2010-10-22
TABLE: List of Critical Components
Object/part No.
Manufacturer/
trademark
type/model
technical data
Label
Various
Various
Enclosure
--
--
- Enclosure material
SABIC INNOVATIVE SE1X
Plastics China Ltd.
Various
Various
70 degree C, if maximum surface temperature not PGDQ2 or PGJI2
specified.
Measured minimum thick 2.75 mm.
-Two halves construction, secured together by
ultrasonic welding. See enclosure 4-01 and 4-02 for
dimension details.
V-1, 105 degree C, minimum 1.5 mm thick.
QMFZ2
Power supply cord
(optional)
CCN
Marks of
Conformity
UL
--
UL
Output cord
Various
Various
Strain Relief for Output
cord
PWB
Appliance Inlet
Various
Various
Various
SUN FAIR
ELECTRIC WIRE &
CABLE (HK) CO LTD
TECX-UNIONS
TECHNOLOGY
CORP
WALTER
ELECTRONIC CO
LTD
DAS & SONS
INTERNATIONAL
LTD
Various
S-02
Detachable, limited to between 1.5 and 4.5 m long,
18 AWG, type SVT or SPT-2, minimum 125 Vac,
10 A, with NEMA 5-15P or 250 Vac, 10 A. The
Other end in an appliance coupler (with cordconnected body, grounding type, suitable for cord
size, rating not less than that of attachment plug)
External used wire, Jacketed. FEP, PTFE, PVC,
TFE, Neoprene, Polyimide or marked VW-1; FT-1,
max. 3.05 m length, 80 degree C, min. 300 V, min.
22AWG. Mechanically secured and soldered to
PWB.
Min V-1, plastic bushing integrally molded on output
cord, see enclosure 4-03 for details
Rated V-1 minimum, 130 degree C minimum
2.5A, 250V, 70 degree C minimum
TU-301 Series
15A, 250V, 105 degree C minimum
AXUT2
UL
ICP
T 3.15A, 250Vac
JDYX2
UL
385T1315
T 3.15A, 250Vac
JDYX2
UL
Appliance Inlet
(Alternate)
Fuse (FS1)
Fuse (FS1) (Alternate)
ZJCZ and RTRT
and AXUT, or
ELBZ
UL
ZJCZ,
AVLV2
UL
QMFZ2
UL
ZPMV2
AXUT2
UL
UL
Issue Date:
2010-03-02
Page 7 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Object/part No.
Manufacturer/
trademark
type/model
technical data
CCN
Marks of
Conformity
Fuse (FS1) (Alternate)
Conquer Electronics
Co Ltd
SAVE FUSETECH
INC
Various
Various
MST
T 3.15A, 250Vac
JDYX2
UL
SS-5
T 3.15A, 250Vac
JDYX2
UL
Various
Various
Listed, T 3.15A, 250Vac
Rated minimum 300 Vac, minimum 385 Vdc.
JDYX
XUHT2
UL
UL
Various
NF00081
--
--
--
--
--
--
Various
Furukawa Electric
Co., Ltd.
Various
Various
Ultra Tech Xiphi
Enterprise Co., Ltd
TENTA ELECTRIC
INDUSTRIAL CO
LTD
CHENG TUNG
INDUSTRIAL CO
LTD
Various
Various
TEX-E
Varnished, see enclosure 4-04 for details, 130
degree C minimum.
Ferrite, measured OD 12 mm by 5 mm ID by 3.5
mm width
Rated minimum 130 degree C.
Rated 130 degree C.
OBMW2
OBJT2
UL
UL
Rated 130 degree C.
Rated minimum 130 degree C.
Max. 0.47 uF, min. 250 Vac, 100 degree C, Class
X1 or X2 type
Max. 0.47 uF, min. 250 Vac, 100 degree C, Class
X1 or X2 type
OANZ2
OBOR2
FOWX2
UL
UL
UL
FOWX2
UL
CTX
Max. 0.47 uF, min. 250 Vac, 100 degree C, Class
X1 or X2 type
FOWX2
UL
NF00083
--
--
--
--
See enclosure 4-05 for details, 130 degree C
minimum.
Ferrite, measured OD 21.5mm by 6 mm ID by 11
mm width
Rated minimum 130 degree C.
Each rated 1M ohm, 1/4W SMD type, connected in
series
Rated 4A, 600 V minimum
Rated 400 V, maximum 120uF, minimum 105
degree C, provided with integral pressure relief
Varnished, see enclosure 4-06 for details, 130
--
--
OBMW2
--
UL
--
---
---
--
--
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Varistor (MOV1)
(Optional)
Line Choke (LF1)
(Optional)
- Core
- Coil
- Triple Insulated
Winding Wire
- Tape
- Varnish
X capcitor (CX1)
(optional)
X capcitor (CX1)
(optional) (Alternate)
X capcitor (CX1)
(optional) (Alternate)
Line Choke (LF2)
(Optional)
- Core
Various
Various
HQX
MEX
- Coil
Bleeder resistor (RS1,
RS2)
Bridge Diode (BD1)
Storage Capacitor (C4)
Various
--
Various
--
---
---
PFC Choke (L1)
Various
RC00136
Issue Date:
2010-03-02
Page 8 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Object/part No.
Manufacturer/
trademark
type/model
- Bobbin
T375J
- Core
- Coil
- Tape
- Varnish
Line Choke (L2)
Chang Chun Plastics
Co., Ltd.
SUMITOMO
BAKELITE CO LTD
-Various
Various
Various
Various
-Various
Various
Various
RC00134
- Core
--
--
- Coil
Tubing/Sleeving
Various
Great Holding
Industrial Co. Ltd.
Heat Sink (HS1)
(Primary)
Heat Sink (HS1)
(Primary) (Alternate)
Heat Sink (HS2)
(Secondary)
Heat Sink (Cover)
(Primary)
Heat Sink (Chassis)
(Primary)
Tubing (For HS1)
- Bobbin (Alternate)
Tubing (For HS2)
technical data
CCN
Marks of
Conformity
QMFZ2
UL
QMFZ2
UL
-OBMW2
OANZ2
OBOR2
--
-UL
UL
UL
--
--
--
OBMW2
YDPU2
UL
UL
--
Various
TFL,
TFS,
TFT
--
degree C minimum.
V-0, 150degree C, Phenolic, thickness 0.8mm
minimum
V-0, 150degree C, Phenolic, thickness 0.71mm
minimum
Ferrite, overall 32.0 by 19.5 by 30.0 mm..
Rated minimum 130 degree C.
Rated 130 degree C.
Rated minimum 130 degree C.
See enclosure 4-07 for details, 130 degree C
minimum.
Ferrite, measured OD 21.5mm by 6 mm ID by 9
mm width
Rated minimum 130 degree C.
Rated 200 degree C
Aluminum material, see enclosure 4-08 for details
--
--
--
--
Aluminum material, see enclosure 4-09 for details
--
--
--
--
Aluminum material, see enclosure 4-10 for details
--
--
--
--
Aluminum material, see enclosure 4-11 for details
--
--
--
--
Aluminum material, see enclosure 4-12 for details
--
--
CHANGYUAN
ELECTRONICS
(SHENZHEN) CO
LTD
CHANGYUAN
ELECTRONICS
(SHENZHEN) CO
LTD
CB-HFT
FEP, PTFE, PVC, TFE, neoprene, polyimide or
marked VW-1; rated minimum 125 degree C,
minimum 300 V, see enclosure 4-08 and 4-09 for
details, thickness 0.4 mm minimum.
FEP, PTFE, PVC, TFE, neoprene, polyimide or
marked VW-1; rated minimum 125 degree C,
minimum 300 V, see enclosure 4-10 for details,
thickness 0.4 mm minimum.
YDPU2
UL
YDPU2
UL
PM-9820
CB-HFT
Issue Date:
2010-03-02
Page 9 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Object/part No.
Transformer (T1) (For
Models with output 12V
to 15.9V.)
Transformer (T1) (For
Models with output 16V24V.)
- Insulation system for
Transformer (T1)
- Core
- Bobbin
- Bobbin (Alternate)
- Tubing/Sleeving
- Varnish
- Varnish (Alternate)
- Insulation Tape
- Insulation Tape
(Alternate)
- Insulation Tape
(Alternate)
- Insulation Tape
(Alternate)
- Triple Insulated
Winding Wire
Semiconductor (US1,
US2, US3)
Bridging -Capacitor
(CY1)
Bridging -Capacitor
(CY1) (Alternate)
Bridging -Capacitor
Manufacturer/
trademark
type/model
technical data
CCN
Marks of
Conformity
XF00500
See enclosure 4-15 for details
--
--
XF00501
See enclosure 4-16 for details
--
--
ENG130-1
Class B, 130 degree C
OBJY2
UL
--
--
--
--
Chang Chun Plastics
Co., Ltd.
SUMITOMO
BAKELITE CO LTD
Great Holding
Industrial Co. Ltd.
T375J
EE type, Ferrite, overall each 28.5mm by 28.5 mm
by 8 mm
V-0, 150degree C, Phenolic, thickness 0.8mm
minimum
V-0, 150degree C, Phenolic, thickness 0.71mm
minimum
Rated 200 degree C
QMFZ2
UL
QMFZ2
UL
YDPU2
UL
Rated minimum 200 degree C.
Rated minimum 130 degree C.
130 degree C.
130 degree C.
OBOR2
OBOR2
OANZ2
OANZ2
UL
UL
UL
UL
PM-9820
John C. Dolph Co.
P D George/Viking
3M Company
3M Company
TFL,
TFS,
TFT
BC-346A
V1630FS
1350T-1
1350F(#)
3M Company
44
130 degree C.
OANZ2
UL
Bondtec Pacific Co.,
Ltd.
Great Leoflon
Industrial Co., Ltd.
--
370S
130 degree C.
OANZ2
UL
TRW(B)
Rated 130 degree C.
OBJT2
UL
--
Rated 0.7A, minimum 650 V.
--
--
TDK Corp
CD
FOWX2
UL
Success Electronics
Co Ltd
WALSIN
SE
Rated maximum 2200 pF, minimum 250 Vac, 125
degree C, Class Y1
Rated maximum 2200 pF, minimum 250 Vac, 125
degree C, Class Y1
Rated maximum 2200 pF, minimum 250 Vac, 125
FOWX2
UL
FOWX2
UL
AH
Issue Date:
2010-03-02
Page 10 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Object/part No.
Manufacturer/
trademark
(CY1) (Alternate)
TECHNOLOGY
CORP / Pan
Overseas
-Sharp Corp.,
Electronic
Components Group
Bright LED
Electronics Corp.
Lite-On Technology
Corp.
Various
Transistor (Q1, Q2)
Optical Isolator (U1)
Optical Isolator (U1)
(Alternate)
Optical Isolator (U1)
(Alternate)
Internal Plastic Part
Materials
Internal Wiring (Primary) Various
type/model
technical data
CCN
Marks of
Conformity
degree C, Class Y1
-PC817
Rated 10A, minimum 600 V.
Minimum 3000 Vac isolation. Double protection.
-FPQU2
-UL
BPC-817xxxxxx
Minimum 3000 Vac isolation. Double protection.
FPQU2
UL
LTV-817
Minimum 3000 Vac isolation. Double protection.
FPQU2
UL
Various
Rated V-2 minimum.
QMFZ2
UL
Various
AVLV2
UL
--
--
Current sense resistor
(R1)
Current sense resistor
(R2)
Glue
--
--
FEP, PTFE, PVC, TFE, neoprene, Polyimide or
marked VW-1; min. 300 V, min. 80 degree C.
0.27 ohm, 2W.
--
--
0.24 ohm, 2W.
--
--
Various
Various
QMFZ2
UL
- Tubing for Functional
Earthing
GUANGZHOU
KAIHENG
ENTERPRISE
GROUP
3M Company
K-2
V-2 min. Components (LF1, LF2, L1, L2, C4, R1,
R2, Output cord) need
FEP, PTFE, PVC, TFE, neoprene, polyimide or
marked VW-1; rated minimum 125 degree C,
minimum 300 V, thickness 0.4 mm minimum.
YDPU2
UL
1350T-1
130 degree C.
OANZ2
UL
Bondtec Pacific Co.,
Ltd.
370S
130 degree C.
OANZ2
UL
Various
Various
V-2 min, see Enclosure 4-13 for details
QMFZ2
UL
FORMEX,DIV OF IL
TOOL WORKS
FORMEX GK
V-2 min, thickness 0.4 mm minimum, see
Enclosure 4-14 for details
QMFZ2
UL
Insulation Tape
(between C10 and Heat
Sink (Cover))
Insulation Tape
(between C10 and Heat
Sink (Cover)) (Alternate)
Insulation sheet
(between PWB and
Appliance Inlet)
Insulation sheet for Heat
Sink (Chassis)
Issue Date:
2010-03-02
Page 11 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Object/part No.
Manufacturer/
trademark
INC,FRMRLY
FASTEX,DIV OF IL
TOOL WORKS INC
type/model
technical data
CCN
Marks of
Conformity
Issue Date:
2010-03-02
Page 12 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Enclosures
Type
Supplement Id
Description
Photographs
3-01
Overall View of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z - 1
Photographs
3-02
Overall View of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z - 2
Photographs
3-03
Internal View of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z - 1
Photographs
3-04
Internal View of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z - 2
Photographs
3-05
Internal View of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z - 3
Photographs
3-06
Internal View of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z - 4
Photographs
3-07
Overall View of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ - 1
Photographs
3-08
Overall View of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ - 2
Photographs
3-09
Internal View of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ - 1
Photographs
3-10
Internal View of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ - 2
Photographs
3-11
Internal View of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ - 3
Photographs
3-12
Internal View of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ - 4
Diagrams
4-01
Plastic Enclosure Dimension of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z
Diagrams
4-02
Plastic Enclosure Dimension of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ
Diagrams
4-03
Strain Relief
Diagrams
4-04
Line Choke (LF1)
Diagrams
4-05
Line Choke (LF2)
Diagrams
4-06
PFC Choke (L1)
Diagrams
4-07
Line Choke (L2)
Diagrams
4-08
Heat Sink (HS1) of GT-41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z
Diagrams
4-09
Heat Sink (HS1) of GT-41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ
Diagrams
4-10
Heat Sink (HS2)
Issue Date:
2010-03-02
Page 13 of 13
Report Reference #
E336418-A29-UL
2010-10-22
Diagrams
4-11
Heat Sink (Cover)
Diagrams
4-12
Heat Sink (Chassis)
Diagrams
4-13
Insulation sheet (between PWB and Appliance Inlet) (For GT41069P9012-T3 Z,
GT-41069PWWVV-X.X-T3 Z)
Diagrams
4-14
Insulation sheet for Heat Sink (Chassis)
Diagrams
4-15
Transformer (T1) (For GT-41069P9012-T3YZ) (P/N: XF00500)
Diagrams
4-16
Transformer (T1) (For
GT-41069PWWVV-X.X-T3YZ) (P/N: XF00501) (Alternate)
Schematics + PWB
5-01
PWB Layout
Schematics + PWB
5-02
Circuit Schematic
7-01
Model difference
Manuals
Miscellaneous
Issue Date:
2010-03-02
Page 1 of 2
Revision Date: 2010-10-22
Test Record
Report Reference #
E336418-A29-UL
Test Record No. 1
copy from E170507-A26-UL-1
Any information and documentation involving UL Mark services are provided on behalf of Underwriters
Laboratories Inc. (UL) or any authorized licensee of UL.
Issue Date:
2010-03-02
Page 2 of 2
Revision Date: 2010-10-22
Test Record
Report Reference #
E336418-A29-UL
Test Record No. 2
--The manufacturer submitted representative production sample of Switching Power Adapter, model GT41069P9012-T3, with eletrical rating:Input 100-240Vac, 1.5A, 50-60Hz, Output 12Vdc, 4A at Tma 60
Degree C for examination and test.
--Unless otherwise indicated, all tests were conducted in UL-CCIC Suzhou Lab.
--Only limted test conducted on GT-41069P9012-T3.
--Test results reported relate only to the items tested.
--Any information and documentation involving UL Mark services are provided on behalf of Underwriters
Laboratories Inc. (UL) or any authorized licensee of UL.
The following tests were conducted:
Test
Testing Location/Comments
End Product Reference Page
Input: Single-Phase (1.6.2)
Heating (4.5.1, 1.4.12, 1.4.13)
Test results are valid only for the tested equipment. These tests are considered representative of the
products covered by this Test Report. The test methods and results of the above tests have been reviewed
and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this
Test Report.
The following tests were waived:
Test
Rationale for Waiving
Strain Relief (3.2.6, 4.2.1, 4.2.7)
Test was been waived because the
stress relief test was waived.
Stress Relief (4.2.7, 4.2.1)
Test was been waived because
74.6°C <101.3°C(previous oven
temperature)
The following supplements are provided as a part of this Test Record. NOTE: These supplements are only
available to the Applicant via the CDA system.
Type
Supplement Id
Description
Attachment
2-01
CRD
Datasheet
2-02
Datasheet
Issue Date:
2010-03-02
Page 1 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
1
GENERAL
Pass
1.5
Components
Pass
1.5.1
General
Pass
1.5.2
Result - Remark
Verdict
Comply with IEC 60950 or relevant component
standard
(see appended table 1.5.1)
Pass
Evaluation and testing of components
Components certified to IEC
harmonized standard and
checked for correct
application.
Pass
Components, for which no
relevant IEC-Standard exist,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 609501 and the relevant component
Standard.
1.5.3
Thermal controls
N/A
1.5.4
Transformers
Transformers comply with the
relevant requirements of this
standard.
See annex C for compliance.
Pass
1.5.5
Interconnecting cables
Interconnecting cables comply
with the relevant requirements
of this standard.
Pass
1.5.6
Capacitors in primary circuits ................................ : - X/Y capacitors complied with
IEC 60384-14: 1993.
- Line-to-line capacitors are
subclass X1 or X2.
- Primary-to-earth capacitors
are subclass Y1.
Pass
1.5.7
Double insulation or reinforced insulation bridged
by components
Pass
1.5.7.1
General
Pass
1.5.7.2
Bridging capacitors
Double Insulation bridged by a
single capacitor complying with
IEC 60384-14: 1993, subclass
Y1.
Pass
Issue Date:
2010-03-02
Page 2 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.5.7.3
Bridging resistors
1.5.7.4
Accessible parts
1.5.8
Components in equipment for IT power systems
N/A
1.6
Power interface
Pass
1.6.1
AC power distribution systems
AC power distribution systems
are classified as TN.
Pass
1.6.2
Input current
The steady state input current
of the equipment did not
exceed the RATED CURRENT
by more than 10% under
NORMAL LOAD.
(see appended table 1.6.2)
Pass
1.6.3
Voltage limit of hand-held equipment
1.6.4
Neutral conductor
1.7
Marking and instructions
1.7.1
Power rating
N/A
Accessible conductive parts
separated from other parts by
DOUBLE or REINFORCED
INSULATION bridged by CY1
comply with the requirements
for LIMITED CURRENT
CIRCUITS.
Pass
N/A
The neutral conductor was
served as a line conductor.
Pass
Pass
Rating marking readily visible
to OPERATOR.
Pass
Rated voltage(s) or voltage range(s) (V) ............... : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Symbol for nature of supply, for d.c. only .............. :
N/A
Rated frequency or rated frequency range (Hz).... : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Rated current (mA or A) ........................................ : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Manufacturer's name or trademark or identification GLOBTEK INC / E170507
mark....................................................................... :
Pass
Type/model or type reference ............................... : Refer to the Model information
at the beginning of this Test
Report.
Pass
Symbol for Class II equipment only....................... :
N/A
Other symbols ....................................................... : Additional symbols/markings
do not give rise to
Pass
Issue Date:
2010-03-02
Page 3 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
misunderstanding.
Certification marks................................................. : UL and C-UL Listing Mark at
least, other certification marks
may be provided when
submitted for national
approvals.
Pass
1.7.2
Safety instructions
Pass
1.7.3
Short duty cycles
N/A
1.7.4
Supply voltage adjustment .................................... :
N/A
1.7.5
Power outlets on the equipment............................ :
N/A
1.7.6
Fuse identification.................................................. : Marking adjacent to fuse on
PWB as
FS1, T 3.15A, 250Vac.
Pass
1.7.7
Wiring terminals
N/A
1.7.7.1
Protective earthing and bonding terminals ............ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
Pass
1.7.8.1
Identification, location and marking ....................... : The function of controls
affecting safety is obvious
regardless of language.
Pass
1.7.8.2
Colours .................................................................. : A green LED is illuminated
when the unit is operating.
Pass
1.7.8.3
Symbols according to IEC 60417 .......................... :
N/A
1.7.8.4
Markings using figures........................................... :
N/A
1.7.9
Isolation of multiple power sources ....................... :
N/A
1.7.10
IT power distribution systems
N/A
1.7.11
Thermostats and other regulating devices
N/A
1.7.12
Language............................................................... : Reviewed only English
markings/instructions.
1.7.13
Durability
1.7.14
Removable parts
N/A
1.7.15
Replaceable batteries
N/A
Operating/safety instructions
made available to the USER.
All markings provided on UL
Recognized Component labels
suitable for surface they are
applied upon.
Language............................................................... :
1.7.16
Operator access with a tool ................................... : No OPERATOR ACCESS
Pass
N/A
Issue Date:
2010-03-02
Page 4 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
AREAS require the use of a
tool.
1.7.17
Equipment for restricted access locations............. : Equipment not intended for
installation in a RESTRICTED
ACCESS LOCATION.
N/A
Issue Date:
2010-03-02
Page 5 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
2.1.1
Protection in operator access areas
Pass
2.1.1.1
Access to energized parts
The operator has access to
bare parts of SELV CIRCUITS.
Verdict
Pass
Test by inspection.................................................. : The OPERATOR cannot
contact with any parts with
only BASIC INSULATION to
ELV CIRCUITS or
HAZARDOUS VOLTAGES.
Pass
Test with test finger ............................................... : The test finger was unable to
contact bare hazardous parts,
basic insulation, or ELV
circuits.
Pass
Test with test pin.................................................... : The test pin was unable to
contact bare hazardous parts.
Pass
Test with test probe ............................................... : No TNV presents.
N/A
2.1.1.2
Battery compartments ........................................... :
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (V); minimum distance (mm)
through insulation .................................................. :
-
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ..................................................... : The output of the power supply
is not an energy hazard.
Pass
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
The voltage at the external
point of disconecttion did
decay to less than 37 percent
of its original value in 1.0
second.
Time-constant (s); measured voltage (V) .............. : CX1 = 0.47 uF.
Measurements taken from lineto-Neutral.
Vo (V pk) = 376 max.
37% Vo (V pk) = 139.1 max.
Vtc (V pk) = 98 max.
Pass
-
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
2.2
SELV circuits
Pass
2.2.1
General requirements
SELV levels are maintained
after single fault condition.
Pass
Issue Date:
2010-03-02
Page 6 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
2.2.2
Voltages under normal conditions (V) ................... : All accessible voltages are
less than 42.4V peak or 60V
dc and are classified as SELV.
Pass
2.2.3
Voltages under fault conditions (V) ....................... : Under fault conditions voltages
never exceed 71V peak and
120V dc and do not exceed
42.4V peak or 60V dc for more
than 0.2 sec.
Pass
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
Pass
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit (method
3)
N/A
2.2.4
Connection of SELV circuits to other circuits ........ : SELV CIRCUITS are only
connected to other SELV
CIRCUITS and/or LIMITED
CURRENT CIRCUITS.
Pass
2.3
TNV circuits
N/A
2.3.1
Limits
2.3.2
2.3.3
Result - Remark
SELV CIRCUITS are
separated from other circuits
by providing DOUBLE or
REINFORCED INSULATION
in the meaning of this
standard.
No TNV presents.
N/A
Type of TNV circuits .............................................. :
-
Separation from other circuits and from accessible
parts
N/A
Insulation employed............................................... :
-
Separation from hazardous voltages
N/A
Insulation employed............................................... :
2.3.4
Verdict
-
Connection of TNV circuits to other circuits
N/A
Insulation employed............................................... :
-
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
Pass
2.4.1
General requirements
The current measured
between the user accessible
part of a limited current circuit
by IEC leakage current meter.
Conducted on bridging
capacitor CY1.
Pass
2.4.2
Limit values
0.7 mA peak.
Pass
Frequency (Hz)...................................................... : 60 Hz
-
Issue Date:
2010-03-02
Page 7 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Measured current (mA).......................................... : 0.165 MIU maximum.
-
Measured voltage (V) ............................................ : 354 V peak maximum.
-
Measured capacitance (mF).................................. : CY1: 2200 pF.
-
2.4.3
Connection of limited current circuits to other
circuits
The LIMITED CURRENT
CIRCUIT connected to other
circuits complies with the
requirements of Sub-clause
2.4.1.
N/A
2.5
Limited power sources
Pass
Inherently limited output
Pass
Impedance limited output
N/A
Overcurrent protective device limited output
N/A
Regulating network limited output under normal
operating and single fault condition
Pass
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
For Model GT-41069P9012power (VA):............................................................ : T3YZ:
Uoc = 12.2 V, Isc = 8.0 A, VA
= 96 VA.
For model GT-41069P90243.75-T3YZ:
Uoc = 24.2 V, Isc = 4.0 A, VA
= 96 VA..
-
Current rating of overcurrent protective device (A) :
-
2.6
Provisions for earthing and bonding
Pass
2.6.1
Protective earthing
N/A
2.6.2
Functional earthing
2.6.3
Protective earthing and protective bonding
conductors
Pass
2.6.3.1
General
Pass
2.6.3.2
Size of protective earthing conductors
Functional earthing separated
from Hazardous voltage by
reinforced insulation.
Functional Earthing connected
to protective bonding.
Insulation on functional
earthing conductor is not
green-yellow.
Power supply cord earthing
conductor complies with Table
3B (Optional provided).
Pass
Pass
Issue Date:
2010-03-02
Page 8 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Rated current (A), cross-sectional area (mm2),
(See appended table 1.5.1)
AWG ...................................................................... :
2.6.3.3
Size of protective bonding conductors
Only functional Earthing
provided.
Verdict
N/A
Rated current (A), cross-sectional area (mm2),
AWG ...................................................................... :
-
2.6.3.4
Resistance (Ohm) of earthing conductors and their
terminations, test current (A) ................................. :
N/A
2.6.3.5
Colour of insulation................................................ :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
-
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
Pass
2.7.1
Basic requirements
Protection provided as part of
the building installation.
Pass
Instructions when protection relies on building
installation
Pluggable Type A.
Pass
2.7.2
Faults not covered in 5.3
Protection from faults not
covered in 5.3 are provided by
installation.
Pass
2.7.3
Short-circuit backup protection
The building installation is
considered as providing shortcircuit backup protection for
PLUGGABLE EQUIPMENT
Pass
Issue Date:
2010-03-02
Page 9 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TYPE A.
2.7.4
Number and location of protective devices ........... : One protective device in the
"LIVE" phase
Pass
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................ : No protective device is
provided in the neutral
conductor.
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ................................................ :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
Pass
2.9.1
Properties of insulating materials
Natural rubber, materials
containing asbestos and
hygroscopic materials are not
used as insulation.
Pass
2.9.2
Humidity conditioning
The humidity treatment was
conducted for 48 hrs.
Electric strength test was
conducted after the humidity
treatment.
Pass
No SAFETY INTERLOCKS
used.
N/A
Humidity (%) .......................................................... : 95
-
Temperature (°C)................................................... : 30
-
2.9.3
Grade of insulation
Pass
2.10
Clearances, creepage distances and distances through insulation
Pass
2.10.1
General
Pass
Pollution degree 2 applicable.
FUNCTIONAL INSULATION
complied with Sub-clause
Issue Date:
2010-03-02
Page 10 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
5.3.4.
2.10.2
Determination of working voltage
Pass
2.10.3
Clearances
2.10.3.1
General
2.10.3.2
Clearances in primary circuit
(see appended table 2.10.3
and 2.10.4).
Pass
2.10.3.3
Clearances in secondary circuits
Functional insulation only.
Waived by short circuit fault
test per Sub-clause 5.3.4.
Pass
2.10.3.4
Measurement of transient voltage levels
2.10.4
Creepage distances
(see appended table 2.10.3
and 2.10.4).
Pass
Pass
N/A
(see appended table 2.10.3
and 2.10.4).
CTI tests ................................................................ : Material Group IIIb assumed
unless otherwise indicated.
100 <= CTI < 175
Pass
-
2.10.5
Solid insulation
Solid or laminated insulating
materials having adequate
thickness are provided.
Pass
2.10.5.1
Minimum distance through insulation
See Table 2.10.5
Pass
2.10.5.2
Thin sheet material
Two layers used, each of
which complies with the
required electric strength test
(see appended table 5.2)
Pass
2.10.5.3
2.10.5.4
Number of layers (pcs) .......................................... : Reinforced Insulation - 2
layers
-
Electric strength test .............................................. : (see appended table 5.2)
-
Printed boards
N/A
Distance through insulation
N/A
Electric strength test for thin sheet insulating
material .................................................................. :
-
Number of layers (pcs) .......................................... :
N/A
Wound components
The employed UL Recognized
wiring meets the requirements
of 2.10.5.4 and Annex U.
Pass
Number of layers (pcs) .......................................... : Three extruded layers.
Pass
Two wires in contact inside wound component;
Physical separation in the form
angle between 45° and 90° ................................... : of insulating sleeving provided
to relieve mechanical stress at
the crossover point.
Pass
Issue Date:
2010-03-02
Page 11 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
2.10.6
Coated printed boards
N/A
2.10.6.1
General
N/A
2.10.6.2
Sample preparation and preliminary inspection
N/A
2.10.6.3
Thermal cycling
N/A
2.10.6.4
Thermal ageing (°C) .............................................. :
N/A
2.10.6.5
Electric strength test .............................................. :
-
2.10.6.6
Abrasion resistance test
2.10.7
2.10.8
Result - Remark
Verdict
N/A
Electric strength test .............................................. :
-
Enclosed and sealed parts .................................... :
N/A
Temperature T1=T2 = Tma - Tamb +10K (°C)...... :
N/A
Spacings filled by insulating compound ................ : Approved Optical Isolator
used.
Pass
Electric strength test .............................................. : (see appended table 2.10.5)
-
2.10.9
Component external terminations
N/A
2.10.10
Insulation with varying dimensions
N/A
Issue Date:
2010-03-02
Page 12 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
3
WIRING, CONNECTIONS AND SUPPLY
Pass
3.1
General
Pass
3.1.1
Current rating and overcurrent protection
All internal wires and
INTERCONNECTING
CABLES possess adequate
cross-sectional areas for their
intended application and all
internal wirings are adequately
insulated.
Pass
3.1.2
Protection against mechanical damage
The wires are routed away
from sharp edges and parts
which could damage
insulation.
Pass
3.1.3
Securing of internal wiring
Internal wiring routed,
supported, clamped or secured
in a manner that excessive
strain on wire and on terminal
connections, loosening of
terminal connections and
damage of conductor
insulation are unlikely.
Pass
3.1.4
Insulation of conductors
The insulation of the individual
conductors is suitable for the
application and the working
voltage.
Pass
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
N/A
3.1.9
Termination of conductors
Pass
10 N pull test
Pass
The sleeving used as
supplementary insulation on
internal wiring is retained by
positive means.
Verdict
3.1.10
Sleeving on wiring
3.2
Connection to an a.c. mains supply or a d.c. mains supply
Pass
3.2.1
Means of connection
Pass
3.2.1.1
Connection to an a.c. mains supply
Pass
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
The unit is provided with an
appliance inlet.
Pass
Issue Date:
2010-03-02
Page 13 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
3.2.3
Permanently connected equipment
Result - Remark
Verdict
N/A
Number of conductors, diameter (mm) of cable and
conduits ................................................................. :
-
3.2.4
Appliance inlets
The appliance inlet complies
with IEC 60320.
Appliance inlet can be inserted
without difficulty and so placed
that, after insertion of the
connector, the equipment is
not supported by the connector
for any position of normal use
on a flat surface.
Pass
3.2.5
Power supply cords
Power supply cord suitable for
application and subject to
country's national code and
regulations to be provided by
the manufacturer.
(Optional provided).
Pass
3.2.5.1
AC power supply cords
(Optional provided).
Pass
Type....................................................................... : (See appended table 1.5.1)
-
Rated current (A), cross-sectional area (mm²),
(See appended table 1.5.1)
AWG ...................................................................... :
-
3.2.5.2
DC power supply cords
3.2.6
Cord anchorages and strain relief
N/A
Strain Relief provided for
output cord.
Pass
Mass of equipment (kg), pull (N) ........................... : Equipment 0.49 kg maximum.
30 N pulling force was applied.
-
Longitudinal displacement (mm) ........................... : 0.6 mm maximum.
-
3.2.7
Protection against mechanical damage
3.2.8
Cord guards
Cord not exposed to sharp
points or edges.
Pass
N/A
D (mm); test mass (g)............................................ :
-
Radius of curvature of cord (mm).......................... :
-
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
The equipment is not
permanently connected or
provided with a nondetachable power supply cord.
Issue Date:
2010-03-02
Page 14 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
3.3.4
Conductor sizes to be connected
Result - Remark
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm²) ............................................................. :
3.3.5
Verdict
-
Wiring terminal sizes
N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
-
3.3.6
Wiring terminals design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
Pass
3.4.1
General requirement
Pass
3.4.2
Disconnect devices
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
No isolating switches fitted in
flexible cords.
N/A
3.4.6
Single-phase equipment and d.c. equipment
Disconnect device disconnects
all poles simultaneously.
Pass
3.4.7
Three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
Pass
3.5.1
General requirements
3.5.2
Types of interconnection circuits ........................... : Interconnection circuits are
SELV CIRCUITS/LIMITED
CURRENT CIRCUITS.
Pass
3.5.3
ELV circuits as interconnection circuits
N/A
The Appliance Inlet is used as
the disconnect device.
Interconnection circuit did
continued conformance to the
requirements of SELV
CIRCUITS.
Pass
Pass
Issue Date:
2010-03-02
Page 15 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
4
PHYSICAL REQUIREMENTS
Pass
4.1
Stability
N/A
Angle of 10°
Result - Remark
Based on construction review,
the test was deemed not
necessary.
Verdict
N/A
Test: force (N)........................................................ :
N/A
4.2
Mechanical strength
Pass
4.2.1
General
Pass
4.2.2
Steady force test, 10 N
Pass
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
4.2.5
Impact test
Fall test
No hazards as a result of the
250 N test.
Pass
Pass
500 g steel sphere ball fall
from 1.3 m height onto the
enclosure, there are no safety
relevant damages.
Pass
Swing test
N/A
4.2.6
Drop test
N/A
4.2.7
Stress relief test
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
N/A
4.3
Design and construction
Pass
4.3.1
Edges and corners
4.3.2
Handles and manual controls; force (N)................ :
N/A
4.3.3
Adjustable controls
N/A
4.3.4
Securing of parts
No indication of shrinkage or
distortion on enclosures due to
the stress relief test ( 101.3
degree C/7 h).
All edges and corners judged
to be sufficiently well rounded
so as not to constitute a
hazard.
No loosening of parts impairing
creepage distances or
clearances over
supplementary or reinforced
insulation is likely to occur.
Pass
Pass
Pass
Issue Date:
2010-03-02
Page 16 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
4.3.5
Connection of plugs and sockets
The equipment does not have
any interchangeable
plugs/sockets.
4.3.6
Direct plug-in equipment
N/A
Dimensions (mm) of mains plug for direct plug-in . :
N/A
Torque and pull test of mains plug for direct plug-in;
torque (Nm); pull (N).............................................. :
N/A
4.3.7
Heating elements in earthed equipment
N/A
4.3.8
Batteries
N/A
4.3.9
Oil and grease
N/A
4.3.10
Dust, powders, liquids and gases
N/A
4.3.11
Containers for liquids or gases
N/A
4.3.12
Flammable liquids.................................................. :
N/A
Quantity of liquid (l)................................................ :
N/A
Flash point (°C)...................................................... :
N/A
4.3.13
Radiation; type of radiation
Pass
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
4.3.13.3
Verdict
Pass
Measured radiation (pA/kg) ................................... :
-
Measured high-voltage (kV) .................................. :
-
Measured focus voltage (kV)................................. :
-
CRT markings........................................................ :
-
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification .......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ....... :
N/A
4.3.13.5
Laser (including LEDs)
This product contains only
visible indicator LEDs (Class
1). No IEC60825-1 evaluation
was deemed necessary.
Additional review may be
required at the discretion of the
accepting NCB.
Laser class ............................................................ : (For indicator LEDs, see above
statement.)
Pass
-
4.3.13.6
Other types ............................................................ :
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No hazardous moving part
N/A
Issue Date:
2010-03-02
Page 17 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
presents.
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
Pass
4.5.1
Maximum temperatures
The equipment and its
components did not attain
excessive temperatures during
normal operation.
(see appended table 4.5)
Pass
Normal load condition per Annex L ....................... : Operated in the most
unfavorable way of operation
given in the operating
instructions until steady
conditions established.
Pass
4.5.2
Resistance to abnormal heat
N/A
4.6
Openings in enclosures
Pass
4.6.1
Top and side openings
Pass
Dimensions (mm) .................................................. : No openings.
4.6.2
Bottoms of fire enclosures
Pass
Construction of the bottom .................................... : No openings.
4.6.3
Doors or covers in fire enclosures
4.6.4
Openings in transportable equipment
4.6.5
Adhesives for constructional purposes
N/A
No openings.
Pass
N/A
Conditioning temperature (°C)/time (weeks) ......... :
-
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Pass
Method 1, selection and application of components Method 1: Selection and
wiring and materials
application of components and
materials which minimize the
possibility of ignition and
spread of flame.
Pass
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Pass
4.7.2.1
Parts requiring a fire enclosure
A fire enclosure covers all
parts except as noted in
4.7.2.2.
Pass
4.7.2.2
Parts not requiring a fire enclosure
Plugs and connectors forming
Pass
Issue Date:
2010-03-02
Page 18 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
part of a power supply cord or
interconnecting cable.
4.7.3
Materials
Pass
4.7.3.1
General
The propagation of fire is
minimized through satisfying
the requirement of
constructions and materials.
Pass
4.7.3.2
Materials for fire enclosures
Equipment is moveable with
mass less than 18 kg. Fire
enclosure material is V-1
minimum
Pass
4.7.3.3
Materials for components and other parts outside
fire enclosures
Pass
4.7.3.4
Materials for components and other parts inside fire PWBs are rated min. V-1.
enclosures
All internal materials are rated
V-2 or better or are mounted
on a PWB rated V-1 or better
Internal wiring is UL
Recognized, marked VW-1 or
FT-1 and strapped by
individual cable ties (where
needed).
See Table 1.5.1 for material
information.
Pass
4.7.3.5
Materials for air filter assemblies
N/A
4.7.3.6
Materials used in high-voltage components
N/A
Issue Date:
2010-03-02
Page 19 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
Pass
5.1.1
General
Pass
5.1.2
Equipment under test (EUT)
Equipment designed for
connection to only one power
source.
Pass
5.1.3
Test circuit
Figure 5A.
Single phase equipment
intended only for connection to
TN system.
Pass
5.1.4
Application of measuring instrument
Using the measuring
instrument specified in annex
D.1.
Test made to 10 x 20 cm metal
foil in contact with accessible
non-conductive part.
Pass
5.1.5
Test procedure
Pass
5.1.6
Test measurements
Pass
Test voltage (V) ..................................................... : 264V/60Hz
-
Measured touch current (mA)................................ : Max. 0.165 mA measured at
output (-) as "e" open.
Max. 0.004 mA measured at
Enclosure with foil as "e"
closed.
-
Max. allowed touch current (mA)........................... : 0.25 mA for Accessible plastic
enclosure.
3.5 mA for output (-) and
output (+).
-
Measured protective conductor current (mA) ........ : --
-
Max. allowed protective conductor current (mA) ... : --
-
5.1.7
Equipment with touch current exceeding 3.5 mA .. :
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and from
telecommunication networks
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable distribution
system
N/A
Test voltage (V) ..................................................... :
-
Measured touch current (mA)................................ :
-
Max. allowed touch current (mA)........................... :
-
5.1.8.2
Summation of touch currents from
N/A
No TNV presents.
N/A
N/A
Issue Date:
2010-03-02
Page 20 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
telecommunication networks ................................. :
5.2
Electric strength
Pass
5.2.1
General
Based on the electric strength
test the use of the insulating
materials within the equipment
is satisfactory.
Pass
5.2.2
Test procedure
No insulation breakdown
detected during the test.
(See Table 5.2 for details)
Pass
5.3
Abnormal operating and fault conditions
5.3.1
Protection against overload and abnormal
operation
5.3.2
Motors
5.3.3
Transformers
Transformers are constructed
in accordance with the
applicable Clause and Annex
C.
(see appended Annex C)
Pass
5.3.4
Functional insulation.............................................. : Functional insulation complies
with the requirements (c).
Pass
5.3.5
Electromechanical components
N/A
5.3.6
Simulation of faults
5.3.7
Unattended equipment
5.3.8
Compliance criteria for abnormal operating and
fault conditions
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
A
Annex A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
B
Annex B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and
5.3.2)
N/A
Pass
(see appended table 5.3)
Pass
N/A
(see appended table 5.3)
Pass
N/A
No fire, emission of molten
metal, deformation, excessive
temperature rises or insulation
breakdown was detected
during these tests.
Pass
Issue Date:
2010-03-02
Page 21 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
C
Annex C, TRANSFORMERS (see 1.5.4 and 5.3.3)
Result - Remark
Verdict
Pass
Position .................................................................. : T1.
-
Manufacturer ......................................................... : (See Table 1.5.1)
-
Type....................................................................... : (See Table 1.5.1)
-
Rated values.......................................................... : (See Table 1.5.1)
-
Method of protection.............................................. : Regulation network provided.
-
C.1
Overload test
(see appended table 5.3)
Pass
C.2
Insulation
(see appended table 5.2)
Pass
Protection from displacement of windings............. : Triple insulated wire used.
Pass
D
Annex D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
Pass
D.1
Measuring instrument
Pass
D.2
Alternative measuring instrument
N/A
E
Annex E, TEMPERATURE RISE OF A WINDING
N/A
F
Annex F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10)
Pass
G
Annex G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
Annex J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7)
N/A
Using the measuring
instrument specified in annex
D.1.
Issue Date:
2010-03-02
Page 22 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
L
Annex L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
Pass
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
L.7
Other business equipment
Pass
M
Annex M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
N
Annex N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and
clause G.5)
N/A
P
Annex P, NORMATIVE REFERENCES
Pass
Q
Annex Q, BIBLIOGRAPHY
Pass
R
Annex R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N/A
S
Annex S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
T
Annex T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see
1.1.2)
N/A
Issue Date:
2010-03-02
Page 23 of 23
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
U
Annex U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
............................................................................... : Used of three layers of
extruded insulation wire were
approved. (See append table
1.5.1)
Verdict
Pass
-
Issue Date:
2010-03-02
Page 1 of 10
Report Reference #
2010-10-22
Enclosure
National Differences
USA / Canada
E336418-A29-UL
Issue Date:
2010-03-02
Page 2 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
USA / Canada - Differences to IEC 60950-1:2001, First Edition
1.1
Equipment able to be installed in accordance with
the National Electrical Code ANSI/NFPA 70 and
the Canadian Electrical Code, Part1, and when
applicable, the National Electrical Safety Code,
IEEE C2.
Pass
1.1.1
Equipment able to be installed in accordance with
ANSI/NFPA 75 and NEC Art. 645 unless intended
for use outside of computer room and provided with
such instructions.
Pass
1.1.2
Equipment in wire-line communication facilities
serving high-voltage electric power stations
operating at greater than 1kV are excluded.
N/A
1.1.2
Special requirements apply to equipment intended
for use outdoors.
N/A
1.4.14
For Pluggable Equipment Type A, the protection in
the installation is assumed to be 20 A.
Pass
1.5.1
All IEC standards for components identified in
Annex P.1 replaced by the relevant requirements of
CSA and UL component standards in Annex P.1.
Pass
1.5.1
All IEC standards for components identified in
Annex P.2 alternatively satisfied by the relevant
requirements of CSA and UL component standards
in Annex P.2.
Pass
1.5.5
Interconnecting cables acceptable for the
INTERCONNECTING
application regarding voltage, current, temperature, CABLES used complied with
flammability, mechanical serviceability and the like. the relevant requirements of
this standard.
Pass
1.5.5
For other than limited power and TNV circuits, the
type of output circuit identified for output connector.
N/A
1.5.5
External cable assemblies that exceed 3.05 m in
length to be types specified in the NEC and CEC.
N/A
1.5.5
Detachable external interconnecting cables 3.05 m
or less in length and provided with equipment
marked to identify the responsible organization and
the designation for the cable.
N/A
1.5.5
Building wiring and cable for use in ducts, plenums
and other air handling space subject to special
requirements and excluded from scope.
N/A
1.5.5
Telephone line and extension cords and the like
comply with UL 1863 and CSA C22.2 No. 233.
N/A
1.6.1.2
Equipment intended for connection to a d.c. power
N/A
Issue Date:
2010-03-02
Page 3 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
(mains) distribution system is subject to special
circuit classification requirements (e.g., TNV-2)
1.6.1.2
Earthing of d.c. powered equipment provided.
N/A
1.7
Lamp replacement information indicated on
lampholder in operator access area.
N/A
1.7.1
Special marking format for equipment intended for
use on a supply system with an earthed neutral
and more than one phase conductor.
N/A
1.7.1
Equipment voltage rating not higher than rating of
the plug except under special conditions.
N/A
1.7.6
Special fuse replacement marking for operator
accessible fuses.
N/A
1.7.7
Identification of terminal connection of the
equipment earthing conductor.
N/A
1.7.7
Connectors and field wiring terminals for external
Class 2 or Class 3 circuits provided with marking
indicating minimum Class of wiring to be used.
N/A
1.7.7
Marking located adjacent to terminals and visible
during wiring.
N/A
2.1.1
Screw shell of Edison-base lampholder tied to the
neutral conductor.
N/A
2.1.1.1
Bare TNV conductive parts in the interior of
equipment normally protected against contact by a
cover intended for occasional removal are exempt
provided instructions include directions for
disconnection of TNV prior to removal of the cover.
N/A
2.3.1.b
Other telecommunication signaling systems (e.g.,
message waiting) than described in 2.3.1(b) are
subject to M.4.
N/A
2.3.1.b
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 V d.c., the maximum current limit through
a 2000 Ohm or greater resistor with loads
disconnected is 7.1 mA peak or 30 mA d.c. under
normal conditions.
N/A
2.3.1.b
Limits for measurements across 5000 ohm resistor
in the event of a single fault are replaced after 200
ms with the limits of M.3.1.4.
N/A
2.3.2
Enamel coating on signal transformer winding wire
allowed as an alternative to Basic insulation in
specific telecommunication applications when
subjected to special construction requirements and
N/A
Issue Date:
2010-03-02
Page 4 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
routine testing.
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV circuits and accessible conductive
parts.
N/A
2.5
Overcurrent protection device required for Class 2
and Class 3 limiting in accordance with the NEC, or
for a Limited Power Source, not interchangeable
with devices of higher ratings if operator
replaceable.
N/A
2.6
Equipment having receptacles for output a.c. power
connectors generated from an internal separately
derived source have the earthed (grounded) circuit
conductor suitably bonded to earth.
N/A
2.6.3.3
For Pluggable Equipment Type A, if neither a) or b)
are applicable, the current rating of the circuit is
taken as 20 A.
N/A
2.6.3.4
Capacity of connection between earthing terminal
and parts required to be earthed subject to special
conditions based on the current rating of the circuit.
N/A
2.6.3.4
Protective bonding conductors and their terminals
of non-standard constructions (e.g. PWB traces)
evaluated to limited short-circuit test of CSA C22.2
No.0.4.
N/A
2.6.4.1
Field wiring terminals for earthing conductors
suitable for wire sizes (gauge) used in US and
Canada.
N/A
2.7.1
Data for selection of special external branch circuit
overcurrent devices marked on the equipment.
N/A
2.7.1
Standard supply outlets protected by overcurrent
device in accordance with the NEC, and CEC, Part
1.
N/A
2.7.1
Overcurrent protection for individual transformers
that distribute power to other units over branch
circuit wiring.
N/A
2.7.1
Additional requirements for overcurrent protection
apply to equipment provided with panelboards.
N/A
2.7.1
Non-motor-operated equipment requiring special
overcurrent protective device marked with device
rating.
N/A
2.10.5.4
Multi-layer winding wire subject to UL component
wire requirements in addition to 2.10.5.4 and
Annex U.
Pass
Issue Date:
2010-03-02
Page 5 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
3.1.1
Permissible combinations of internal wiring/external All internal wires possess
cable sizes for overcurrent and short circuit
adequate cross-sectional
protection.
areas for their intended
application and all internal
wirings are adequately
insulated.
Pass
3.1.1
All interconnecting cables protected against
overcurrent and short circuit.
Pass
3.2
Wiring methods permit connection of equipment to
primary power supply in accordance with the NEC
and CEC, Part 1.
Pass
3.2.1
Permitted use for flexible cords and plugs.
Pass
3.2.1
Flexible cords provided with attachment plug rated
125% of equipment current rating.
Pass
3.2.1
Any Class II equipment provided with 15 or 20 A
standard supply outlets, Edison-base lampholders
or single pole disconnect device provided with a
polarized type attachment plug.
N/A
3.2.1.2
Equipment intended for connection to DC mains
supply power systems complies with special wiring
requirements (e.g., no permanent connection to
supply by flexible cord).
N/A
3.2.1.2
Equipment with one pole of the DC mains supply
connected to both the equipment mains input
terminal and the main protective earthing terminal
provided with special instructions and construction
provisions for earthing
N/A
3.2.1.2
Equipment with means for connecting supply to
earthing electrode conductor has no switches or
protective devices between supply connection and
earthing electrode connection.
N/A
3.2.1.2
Special markings and instructions for equipment
with provisions to connect earthed conductor of a
DC supply circuit to earthing conductor at the
equipment.
N/A
3.2.1.2
Special markings and instructions for equipment
with earthed conductor of a DC supply circuit
connected to the earthing conductor at the
equipment.
N/A
All INTERCONNECTING
CABLES possess adequate
cross-sectional areas for their
intended application and all
internal wirings are adequately
insulated.
Issue Date:
2010-03-02
Page 6 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
3.2.1.2
Terminals and leads provided for permanent
connection of DC powered equipment to supply
marked to indicate polarity if reverse polarity may
result in a hazard.
N/A
3.2.3
Permanently connected equipment has provision
for connecting and securing a field wiring system
(i.e. conduit, or leads etc.) per the NEC and CEC,
Part 1.
N/A
3.2.3
Permanently connected equipment may have
terminals or leads not smaller than No. 18 AWG
(0.82 mm²) and not less than 152 mm in length for
connection of field installed wiring.
N/A
3.2.3
If supply wires exceed 60 °C, marking indicates
use of 75 °C or 90 °C wiring for supply connection
as appropriate.
N/A
3.2.3
Equipment compatible with suitable trade sizes of
conduits and cables.
N/A
3.2.5
Length of power supply cord limited to between 1.5
and 4.5 m unless shorter length used when
intended for a special installation.
Pass
3.2.5
Conductors in power supply cords sized according
to NEC and CEC, Part I.
Pass
3.2.5
Power supply cords and cord sets incorporate
flexible cords suitable for the particular application.
Pass
3.2.6
Strain relief provided for non-detachable
interconnecting cables not supplied by a limited
power source.
Pass
3.2.9
Adequate wire bending space and volume of field
wiring compartment required to properly make the
field connections.
N/A
3.2.9
Equipment intended solely for installation in
Restricted Access Locations using low voltage d.c.
systems may not need provision for connecting and
securing a field wiring system. A method of
securing wiring or instructions provided to ensure
the wiring is protected from abuse.
N/A
3.3
Field wiring terminals provided for interconnection
of units for other then LPS or Class 2 circuits also
comply with 3.3.
N/A
3.3
Interconnection of units by LPS or Class 2
conductors may have field wiring connectors other
than those specified in 3.3 if wiring is reliably
separated.
N/A
Issue Date:
2010-03-02
Page 7 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
3.3.1
Terminals for the connection of neutral conductor
identified by a distinctive white marking or other
equally effective means.
N/A
3.3.3
Wire binding screw terminal permitted for
connection of No. 10 AWG (5.3 mm²) or smaller
conductor if provided with upturned lugs, cupped
washer or equivalent retention.
N/A
3.3.4
Terminals accept wire sizes (gauge) used in the
U.S. and Canada.
N/A
3.3.4
Terminals accept current-carrying conductors rated
125% of the equipment current rating.
N/A
3.3.6
Field wiring terminals marked to indicate the
material(s) of the conductor appropriate for the
terminals used.
N/A
3.3.6
Connection of an aluminum conductor not
permitted to terminal for equipment earthing
conductor.
N/A
3.3.6
Field wiring connections made through the use of
suitable pressure connectors (including set screw
type), solder lugs or splices to flexible leads.
N/A
3.4.2
Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with
motor rated more than 1/3 hp or more than 120 V.
N/A
3.4.8
Vertically mounted disconnect devices oriented so
up position of handle is "on".
N/A
3.4.11
For computer-room applications, equipment with
battery systems capable of supplying 750 VA for 5
min require battery disconnect means.
N/A
4.2.8.1
Special opening restrictions for enclosures around
CRTs with face dimension of 160 mm or more.
N/A
4.2.9
Compartment housing high-pressure lamp marked
to indicate risk of explosion.
N/A
4.3.2
Loading test for equipment with handle(s) used to
support more than 9 kg tested at four times the
weight of the unit.
N/A
4.3.6
In addition to the IEC requirements, Direct Plug-in
Equipment complies with UL 1310 or CSA 223
mechanical assembly requirements.
N/A
4.3.12
The maximum quantity of flammable liquid stored
in equipment complies with ANSI/NFPA 30(Table
NAE.6).
N/A
Issue Date:
2010-03-02
Page 8 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
4.3.12
Equipment using replenishable liquids marked to
indicate type of liquid to be used.
N/A
4.3.13.2
Equipment that produces x-radiation and does not
comply with 4.3.12 under all conditions of servicing
marked to indicate the presence of radiation where
readily visible.
N/A
4.3.13.5
Requirements contained in the applicable national
codes and regulations apply to lasers (21 CFR
1040 and REDR C1370).
N/A
4.7
Automated information storage equipment intended
to contain more than 0.76 m³ of combustible media
requires provision for automatic sprinklers or a
gaseous agent extinguishing system.
N/A
4.7.3.1
Equipment for use in environmental air space other
than ducts or plenums provided with metal
enclosure or with non-metallic enclosure having
adequate fire-resistance and low smoke producing
characteristics. Low smoke-producing
characteristics evaluated according to UL 2043.
Equipment for installation in space used for
environmental air as described in Sec. 300-22(c) of
the NEC provided with instructions indicating
suitability for installation in such locations.
N/A
4.7.3.1
Flame spread rating for external surface of
combustible material with exposed area greater
than 0.93 m² or a single dimension greater than 1.8
m; 50 or less for computer room applications or
200 or less for other applications.
N/A
4.7.3.4
Wire marked "VW-1" or "FT-1" considered
equivalent.
Pass
5.1.8.2
Special earthing provisions and instructions for
equipment with high touch current due to
telecommunication network connections.
N/A
5.1.8.3
Touch current due to ringing voltage for equipment
containing telecommunication network leads.
N/A
5.3.6
Overloading of SELV connectors and printed wiring
board receptacles accessible to the operator.
N/A
5.3.6
Tests interrupted by opening of a component
repeated two additional times.
N/A
5.3.8.1
Test interrupted by opening of wire or trace subject
to certain conditions.
N/A
6
Specialized instructions provided for telephones
that may be connected to a telecommunications
N/A
Issue Date:
2010-03-02
Page 9 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
network.
6
Marking identifying function of telecommunication
type connectors not used for connection to a
telecommunication network.
N/A
6.2.1
Special requirements for enameled wiring used as
electrical separation provided between parts
connected to telecommunication network and
telecommunication circuitry intentionally isolated
from network.
N/A
6.2.1
Digital line termination equipment (e.g., NCTE)
subject to separation requirements.
N/A
6.3
Equipment remotely powered over
telecommunication wiring systems provided with
specialized markings adjacent to the connection.
N/A
6.3
Overcurrent protection incorporated into equipment
to provide power over telecommunication wiring
system not interchangeable with devices of higher
ratings if operator replaceable.
N/A
6.4
Additional requirements for equipment intended for
connection to a telecommunication network using
cable subject to overvoltage from power line
failures (Fig. 6C).
N/A
6.4
Where 26 AWG line cord required by Fig. 6C,
either the cord is provided with the equipment or
described in the safety instructions.
N/A
6.5
Acoustic pressure from an ear piece less than 136
dBA for short duration disturbances, and less than
125 dBA for handsets, 118 dBA for headsets, and
121 dBA for insert earphones, for long duration
disturbances.
N/A
7
Equipment associated with the cable distribution
system may need to be subjected to applicable
parts of Chapter 8 of the NEC.
N/A
H
Ionizing radiation measurements made under
single fault conditions in accordance with the
requirements of the Code of Federal Regulations
21 CFR 1020 and the Canadian Radiation Emitting
Devices Act, REDR C1370.
N/A
M.2
Continuous ringing signals evaluated to Method A
subjected to special accessibility considerations.
N/A
M.4
Special requirements for message waiting and
similar telecommunications signals.
N/A
Issue Date:
2010-03-02
Page 10 of 10
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
NAC
Equipment intended for use with a generic
secondary protector marked with suitable
instructions.
N/A
NAC
Equipment intended for use with a specific primary
or secondary protector marked with suitable
instructions.
N/A
NAF
Household/Home Office Document Shredders
N/A
NAF.1.7
Markings and instructions alert the user to key
safety considerations related to use of shredders,
including not intended to be used by children, avoid
touching document feed opening, avoid clothes
and hair entanglement, and avoid aerosol products.
N/A
NAF.2.8.3
Safety interlock cannot be inadvertently activated
by the articulated accessibility probe (figure
NAF.1).
N/A
NAF.3.4
Provided with an isolating switch complying with
3.4.2, including 3 mm contact gap, with appropriate
markings associated with the switch.
N/A
NAF.4.4
Hazardous moving parts are not accessible to the
user, as determined using the articulated
accessibility probe (figure NAF.1) and the
accessibility probe/wedge (figures NAF.2/NAF.3).
N/A
Issue Date:
2010-03-02
Page 1 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
1.6.2
TABLE: electrical data (in normal conditions)
I rated (A)
U (V)
---
--
--
FS1
--
104.44
1163
I fuse (mA) condition/status
-Model:
GT-41069P9012-T3YZ.
1163
Maximum normal load
FS1
--
104.37
1162
1162
Maximum normal load
FS1
1.5
103.56
1037
1037
Maximum normal load
FS1
1.5
103.52
1037
1037
Maximum normal load
FS1
1.5
101.53
432
432
Maximum normal load
FS1
1.5
101.46
436
436
Maximum normal load
FS1
--
101.44
411
411
Maximum normal load
FS1
--
101.42
415
415
Maximum normal load
FS1
--
101.37
397
397
Maximum normal load
FS1
--
101.34
402
402
Maximum normal load
--
--
--
--
--
FS1
--
101.97
1134
1134
Model:
GT-41069P9019-T3YZ.
Maximum normal load
FS1
--
101.92
1134
1134
Maximum normal load
FS1
1.5
101.20
1013
1013
Maximum normal load
FS1
1.5
101.16
1013
1013
Maximum normal load
FS1
1.5
99.57
425
425
Maximum normal load
FS1
1.5
99.50
428
428
Maximum normal load
FS1
--
99.45
403
403
Maximum normal load
FS1
--
99.45
408
408
Maximum normal load
FS1
--
99.40
390
390
Maximum normal load
FS1
--
99.36
395
395
Maximum normal load
--
--
--
--
--
Model:
90Vac/50H
z
90Vac/60H
z
100Vac/50
Hz
100Vac/60
Hz
240Vac/50
Hz
240Vac/60
Hz
254Vac/50
Hz
254Vac/60
Hz
264Vac/50
Hz
264Vac/60
Hz
--
I (mA)
Pass
fuse #
--
90Vac/50H
z
90Vac/60H
z
100Vac/50
Hz
100Vac/60
Hz
240Vac/50
Hz
240Vac/60
Hz
254Vac/50
Hz
254Vac/60
Hz
264Vac/50
Hz
264Vac/60
Hz
--
P (W)
Verdict
Issue Date:
2010-03-02
Page 2 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
FS1
--
--
90Vac/50H
z
90Vac/60H
z
100Vac/50
Hz
100Vac/60
Hz
240Vac/50
Hz
240Vac/60
Hz
254Vac/50
Hz
254Vac/60
Hz
264Vac/50
Hz
264Vac/60
Hz
--
FS1
--
FS1
1.5
FS1
1.5
FS1
1.5
FS1
1.5
FS1
--
FS1
--
FS1
--
FS1
--
Test
record
No.2
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
--1.5
1.5
1.5
1.5
---
90V/50Hz
90V/60Hz
100V/50Hz
100V/60Hz
240V/50Hz
240V/60Hz
264V/50Hz
264V/60Hz
Result - Remark
Verdict
101.57
1132
1132
GT-41069P9024-T3YZ.
Maximum normal load
101.50
1132
1132
Maximum normal load
100.75
1010
1010
Maximum normal load
100.72
1010
1010
Maximum normal load
99.55
424
424
Maximum normal load
99.47
428
428
Maximum normal load
99.43
403
403
Maximum normal load
99.42
407
407
Maximum normal load
99.35
389
389
Maximum normal load
99.31
394
394
Maximum normal load
--
--
--
--
54.9
54.9
54.7
54.6
55.5
55.4
55.5
55.3
609.5
607.6
548.0
545.1
250.1
255.0
235.2
240.0
609.5
607.6
548.0
545.1
250.1
255.0
235.2
240.0
Output was loaded as 12Vdc,4A
Output was loaded as 12Vdc,4A
Output was loaded as 12Vdc,4A
Output was loaded as 12Vdc,4A
Output was loaded as 12Vdc,4A
Output was loaded as 12Vdc,4A
Output was loaded as 12Vdc,4A
Output was loaded as 12Vdc,4A
supplementary information:
Maximum normal load: Output connected to resistive load as rated and operated continuously.
2.10.3 and
2.10.4
Pass
TABLE: clearance and creepage distance measurements
clearance cl and creepage
distance dcr at/of:
GT-41069P9012-T3YZ.
T1 Pin A TO T1 Pin 1
T1 Pin A TO T1 Pin 2
T1 Pin A TO T1 Pin 4
T1 Pin A TO T1 Pin 5
T1 Pin B TO T1 Pin 1
Up
(V)
-512
460
360
364
512
U r.m.s. (V) required cl
(mm)
--349
4.4
315
4.2
167
4
165
4
361
4.4
cl (mm)
-8.98
8.98
7.74
7.74
8.98
required
dcr (mm)
-7.2
6.8
4
4
7.4
dcr
(mm)
-8.98
8.98
7.74
7.74
8.98
Issue Date:
2010-03-02
Page 3 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
T1 Pin B TO T1 Pin 2
T1 Pin B TO T1 Pin 4
T1 Pin B TO T1 Pin 5
T1 Pin 9 To T1 Pin 1
T1 Pin 9 To T1 Pin 2
T1 Pin 9 To T1 Pin 4
T1 Pin 9 To T1 Pin 5
U1 Pin 1 TO U1 Pin 3
U1 Pin 1 TO U1 Pin 4
U1 Pin 2 TO U1 Pin 3
U1 Pin 2 TO U1 Pin 4
CY1 Pin 1 TO CY1 Pin 2
D4 Pin 1 TO U1 Pin 2
C5 Pin 1 TO RS48 Pin 1
C5 Pin 1 TO RS49 Pin 1
GT-41069P9019-T3YZ.
T1 Pin A TO T1 Pin 1
T1 Pin A TO T1 Pin 2
T1 Pin A TO T1 Pin 4
T1 Pin A TO T1 Pin 5
T1 Pin B TO T1 Pin 1
T1 Pin B TO T1 Pin 2
T1 Pin B TO T1 Pin 4
T1 Pin B TO T1 Pin 5
T1 Pin 9 To T1 Pin 1
T1 Pin 9 To T1 Pin 2
T1 Pin 9 To T1 Pin 4
T1 Pin 9 To T1 Pin 5
U1 Pin 1 TO U1 Pin 3
U1 Pin 1 TO U1 Pin 4
U1 Pin 2 TO U1 Pin 3
U1 Pin 2 TO U1 Pin 4
CY1 Pin 1 TO CY1 Pin 2
D4 Pin 1 TO U1 Pin 2
C5 Pin 1 TO RS48 Pin 1
C5 Pin 1 TO RS49 Pin 1
GT-41069P9024-T3YZ.
T1 Pin A TO T1 Pin 1
T1 Pin A TO T1 Pin 2
T1 Pin A TO T1 Pin 4
T1 Pin A TO T1 Pin 5
T1 Pin B TO T1 Pin 1
T1 Pin B TO T1 Pin 2
T1 Pin B TO T1 Pin 4
T1 Pin B TO T1 Pin 5
T1 Pin 9 To T1 Pin 1
T1 Pin 9 To T1 Pin 2
412
336
394
526
168
176
208
348
346
346
346
354
418
352
354
-548
486
426
422
556
392
350
406
546
174
186
220
356
352
352
352
350
410
350
348
-560
502
426
416
572
394
356
412
551
176
Result - Remark
317
163
165
184
64
67
77
170
169
170
168
174
183
173
174
-344
302
178
175
364
300
173
175
181
72
83
86
176
174
175
174
172
177
172
172
-355
305
180
175
377
303
174
177
188
58
4
4
4
4.4
4
4
4
4
4
4
4
4
4
4
4
-4.4
4.2
4.2
4.2
4.4
4
4
4
4.4
4
4
4
4
4
4
4
4
4
4
4
-4.4
4.4
4.2
4
4.6
4
4
4
4.4
4
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
Verdict
6.8
4
4
4
4
4
4
4
4
4
4
4
4
4
4
-7.2
6.6
4
4
7.6
6.4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
-7.4
6.6
4
4
7.8
6.6
4
4
4
4
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
Issue Date:
2010-03-02
Page 4 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
T1 Pin 9 To T1 Pin 4
T1 Pin 9 To T1 Pin 5
U1 Pin 1 TO U1 Pin 3
U1 Pin 1 TO U1 Pin 4
U1 Pin 2 TO U1 Pin 3
U1 Pin 2 TO U1 Pin 4
CY1 Pin 1 TO CY1 Pin 2
D4 Pin 1 TO U1 Pin 2
C5 Pin 1 TO RS48 Pin 1
C5 Pin 1 TO RS49 Pin 1
179
215
376
374
378
374
334
432
334
332
Result - Remark
67
82
191
190
190
189
162
192
162
162
4
4
4
4
4
4
4
4.2
4
4
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
Verdict
4
4
4
4
4
4
4
4
4
4
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
supplementary information:
- Functional Insulation employed and complied with the requirements of 5.3.4 (a), (b), or (c).
2.10.5
Pass
TABLE: distance through insulation measurements
distance through insulation di at/of:
Up
(V)
Optical Isolator (U1)
420
test voltage (V)
3000Vac
required di
(mm)
0.4
di
(mm)
>0.4
supplementary information:
--
4.5
TABLE: temperature rise measurements
test voltage (V).......................................... -t1 (°C)........................................................ -t2 (°C)........................................................ --
Pass
--
--
--
--
—
--
--
--
--
—
--
--
--
--
—
maximum temperature T of part/at:
Model:
GT-41069P9012-T3YZ.
Test condition
Duration (hrs)
1.AC Inlet
2.LF1 coil
3.LF2 coil
4.L1 coil
5.L2 coil
6.L3 coil/C10
7.T1 coil
T (°C)
--
--
--
--
--
allowed
Tmax (°C)
--
90V,
60Hz
(Label
down)
3
62.0
90.1
109.7
96.1
107.7
93.4
98.9
264V,
60Hz
(Label
down)
3.28
54.0
73.7
79.9
78.8
80.8
84.1
84.6
90V,
60Hz
(Label
up)
3.38
63.4
93.7
115.0
101.8
111.5
95.8
103.8
264V,
60Hz
(Label
up)
3
54.9
75.1
81.9
81.4
82.3
85.4
86.7
--
--
---------
-70
130
130
130
130
130
110
Issue Date:
2010-03-02
Page 5 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
8.T1 core
9.U1 body
10.CY1 body
11.CX1 body
12.C4 body
13.BD1 body
14.PCB under Q2
15. PCB under Q1/D1
16. PCB under Q3
17.MOV1 body
18.Inside Enclosure near T1
19.Outside Enclosure near T1
20.Ambient
Model:
GT-41069P9019-T3YZ.
Test condition
Duration (hrs)
1.AC Inlet
2.LF1 coil
3.LF2 coil
4.L1 coil
5.L2 coil
6.L3 coil/C10
7.T1 coil
8.T1 core
9.U1 body
10.CY1 body
11.CX1 body
12.C4 body
13.BD1 body
14.PCB under Q2
15. PCB under Q1/D1
16. PCB under Q3
17.MOV1 body
18.Inside Enclosure near T1
19.Outside Enclosure near T1
20.Ambient
Model:
GT-41069P9024-T3YZ.
Duration (hrs)
1.AC Inlet
2.LF1 coil
3.LF2 coil
4.L1 coil
5.L2 coil
Result - Remark
Verdict
96.3
95.4
91.9
93.5
98.4
106.4
100.6
107.2
94.4
86.2
81.4
51.6
40.7
--
81.9
84.2
78.2
76.3
83.2
80.2
83.5
85.7
84.8
72.3
70.8
48.7
40.7
--
101.5
97.1
93.2
99.3
103.1
114.5
103.8
110.8
97.0
89.9
91.3
70.7
41.0
--
83.9
84.5
77.3
78.9
85.2
83.1
84.0
86.7
85.7
74.0
76.9
62.6
40.7
--
---------------
110
100
125
100
105
130
130
130
130
130
95
95
---
90V,
60Hz
(Label
down)
3.6
58.9
86.2
101.5
93.6
96.3
76.9
87.2
86.4
85.8
82.0
89.8
87.1
99.3
90.3
102.0
86.0
83.8
69.9
47.4
40.4
--
264V,
60Hz
(Label
down)
2.56
53.1
72.3
76.4
77.3
76.5
71.2
77.6
77.1
78.5
72.6
74.6
75.3
76.4
78.2
84.3
80.4
72.0
62.4
45.8
40.4
--
90V,
60Hz
(Label
up)
3.31
62.8
86.2
104.3
96.1
100.2
75.3
90.1
89.1
86.1
83.9
91.3
91.6
103.4
92.9
104.0
85.8
84.3
79.8
62.4
40.8
--
264V,
60Hz
(Label
up)
2.83
54.8
71.7
78.0
78.7
78.6
69.5
79.0
78.0
78.0
73.4
74.9
77.6
78.6
79.3
84.9
79.5
71.4
69.2
57.0
40.5
--
--
--
-----------------------
-70
130
130
130
130
130
110
110
100
125
100
105
130
130
130
130
130
95
95
---
3.31
57.0
85.6
100.3
90.3
101.4
2.61
52.1
73.2
78.9
77.5
80.1
3.41
59.3
88.5
104.3
95.2
104.5
3.3
53.4
75.1
81.4
80.7
82.3
-------
-70
130
130
130
130
Issue Date:
2010-03-02
Page 6 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
6.L3 coil/C10
7.T1 coil
8.T1 core
9.U1 body
10.CY1 body
11.CX1 body
12.C4 body
13.BD1 body
14.PCB under Q2
15. PCB under Q1/D1
16. PCB under Q3
17.MOV1 body
18.Inside Enclosure
19.Outside Enclosure
81.6
88.0
89.0
87.6
84.9
88.7
94.5
101.6
93.0
100.9
85.8
82.1
76.5
47.2
20.Ambient
Test record No.2
Test Condition
40.7
-90V,
60Hz
(Label
up)
1.AC inlet
2.LF1 coil
3.LF2 coil
4.L1 coil
5.L2 coil
6.L3 coil
7.T1 coil
8.T1 core
9.U1 body
10.CY1 body
11.CX1 body
12.C4 body
13.PCB under Q2
14.Inside enclosure near T1
15.Outside enclosure near T1
20.Ambient
Test Duration
temperature T of winding:
--
75.9
78.7
78.6
81.1
75.3
75.1
84.1
79.4
82.2
84.4
81.5
71.6
68.1
45.7
40.7
-90V,
60Hz
(Label
up) shift
to 60
Degree
C
66.7 67.6
76.0 76.9
85.8 86.7
81.3 82.2
82.4 83.3
80.4 81.3
92.9 93.8
87.2 88.1
82.9 83.8
84.3 85.2
79.3 80.2
81.4 82.3
77.4 78.3
72.8 73.7
65.5 66.4
59.1 60.0
Degre Degree
eC
C
1h54 -min
R1 ()
--
81.2
90.8
92.7
87.0
86.9
93.0
96.6
105.9
95.7
103.5
86.2
84.7
85.1
63.9
75.6
80.6
81.2
80.5
76.7
77.9
85.5
82.3
83.8
86.1
81.7
73.2
74.6
59.8
41.0
-264V,
50Hz
(Label
up)
41.0
-264V,
50Hz
(Label
up) shift
to 60
Degree
C
66.2
66.8
75.5
76.1
80.4
81.0
82.2
82.8
81.8
82.4
81.8
82.4
95.8
96.4
89.6
90.2
85.0
85.6
86.6
87.2
79.0
79.6
83.3
83.9
79.4
80.0
74.0
74.6
66.2
66.8
59.4
60.0
Degree Degree
C
C
2h19min -R2 ( )
--
T (°C)
--
Verdict
---------------
130
110
110
100
125
100
105
130
130
130
130
130
95
95
----
----
-----------------
70
130
130
130
130
130
110
110
100
125
100
105
130
95
95
--
--
--
allowed
insulation
Tmax (°C)
class
---
Issue Date:
2010-03-02
Page 7 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
supplementary information:
-- The temperatures were measured by thermal couple under worst case normal mode defined in 1.2.2.1 and
described in 1.6.2 at voltages as described in 1.4.5.
-- With maximum ambient temperature specified as 40 degree C, therefore, the maximum temperature is as
follows:
-- Winding components: (thermal couple used)
Class B (Transformers: T1) -> Tmax = 120 - 10 = 110 degree C
-- Components with:
max. absolute temp. of 70 degree C (Inlet).
max. absolute temp. of 100 degree C (U1, CX1);
max. absolute temp. of 105 degree C (C4);
max. absolute temp. of 125 degree C (CY1);
max. absolute temp. of 130 degree C (PWB)
-- User accessible area:
Plastic Enclosure: 95 degree C
4.5.2
N/A
TABLE: ball pressure test of thermoplastics
allowed impression diameter (mm) ........................ :
—
part
test temperature (°C)
impression diameter
(mm)
supplementary information:
4.7
part
--
Pass
TABLE: resistance to fire
manufacturer of material
--
type of material
--
thickness(mm)
flammability
class
--
--
supplementary information:
See Critical Components for details.
5.2
Pass
TABLE: electric strength tests, impulse tests and voltage surge tests
test voltage applied between:
2.10.5.2, 2.9.5
Transformer/Insulation Electric Strength Test
test voltage (V)
a.c./d.c.
--
breakdown
Yes / No
--
Issue Date:
2010-03-02
Page 8 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Result - Remark
One layer of insulation Tape for T1
3M Company / 1350T-1, 1350F(#), 44
Bondtec Pacific Co., Ltd. / 370S
Transformer (T1) Primary to Secondary
Transformer (T1) Secondary to Core
5.2.2
Electric Strength Test
Unit Primary to Secondary Output
Unit Primary to Enclosure with foil
Tubing (For HS1 and HS2):
CHANGYUAN ELECTRONICS (SHENZHEN) CO LTD / CBHFT
Tubing for Functional Earthing:
GUANGZHOU KAIHENG ENTERPRISE GROUP / K-2
Insulating Tape (between C10 and Heat Sink (Cover)):
3M Company / 1350T-1
Insulation sheet for Heat Sink (Chassis):
FORMEX,DIV OF IL TOOL WORKS INC,FRMRLY FASTEX,DIV
OF IL TOOL WORKS INC / FORMEX GK
Verdict
3000 Vac
No
3000 Vac
3000 Vac
--
No
No
--
3000 Vac
3000 Vac
3000 Vac
No
No
No
3000 Vac
No
3000 Vac
No
3000 Vac
No
supplementary information:
--
5.3
Pass
TABLE: fault condition tests
ambient temperature (°C) ....................................... : 25 degree C, if ambient not
specified.
model/type of power supply.................................... : --
—
manufacturer of power supply ................................ : -rated markings of power supply.............................. : --
—
test time
—

component fault
No.
---
test voltage
(V)
--
--
fuse
No.
--
--
--
--
--
--
fuse current
(A)
5.3.1, 5.3.4,
5.3.6
--
result
BD1
Short
1sec
FS1
0.438 to 0
C4
Short
1sec
FS1
0.438 to 0
NB,NC,NT,CD(FS1) (b)
Q3
Short
1sec
FS1
0.438 to 0.26
NB,NC,NT,IP(US2) (a)
U1 Pin 1-2
Short
1sec
FS1
0.438 to 0.045 NB,NC,NT,IP(US2) (a)
U1 Pin 3-4
Short
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
Model:
GT-41069P9012-T3YZ.
NB,NC,NT,CD(FS1) (b)
1sec
FS1
0.438 to 0.044 NB,NC,NT,IP(US2) (a)
Component Failure Test
Issue Date:
2010-03-02
Page 9 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
U1 Pin 1
Open
U1 Pin 3
Open
Q1(G-D)
Short
Q1(D-S)
Short
Q1(G-S)
Short
Q2(G-D)
Short
Q2(D-S)
Short
Q2(G-S)
Short
R1
Short
R2
Short
US1 Pin 56
US1 Pin 67
US2 Pin 26
US2 Pin 46
US2 Pin 56
US2 Pin 3
Short
US3 Pin 56
US3 Pin 67
--
Short
--
Result - Remark
Verdict
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
1sec
FS1
0.438 to 0.043 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.438 to 0.043 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.442 to 0
1sec
FS1
0.440 to 0
6.5hrs
FS1
0.699
1sec
FS1
0.440 to 0
1sec
FS1
1sec
FS1
4.1hrs
FS1
1sec
FS1
3.4hrs
FS1
0.703
NB,NC,NT, (c)
4.2hrs
FS1
0.712
NB,NC,NT, (c)
1sec
FS1
0.439 to 0.042 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.042 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.042 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.041 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.052 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.052 NB,NC,NT,IP(US2) (a)
--
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
--
0.962 to 0.054 NB,NC,NT, Unit shutdown
after fault condition at 90
mins.
0.438 to 0.042 NB,NC,NT,IP(US2) (a)
--
--
--
--
--
--
5.3.3, 5.3.6b,
Annex C.1
--
240Vac/
60Hz
240Vac/
60Hz
10min
FS1
10.8hr
FS1
Short
Short
Short
Short
Open
Short
T1 after Q3 Short
T1 after Q3 Overload
NB,NC,NT,CD(FS1,Q1,R1)
(b)
NB,NC,NT,CD(FS1,Q1,R1)
(b)
NB,NC,NT, (c)
NB,NC,NT,CD(FS1,Q2,R2)
(b)
0.439 to 0
NB,NC,NT,CD(FS1,Q2,R2)
(b)
0.439 to 0.041 NB,NC,NT,IP(US2) (a)
Transformer Abnormal
Operation Test
Model:
GT-41069P9012-T3YZ.
0.438 to 0.176 NB,NC,NT,IP(US2) (a)
0.471 to 0.045 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 8.0A,
T1 coil:113.4 degree C,
T1 core:106.5 degree C,
Issue Date:
2010-03-02
Page 10 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
--
Requirement + Test
Result - Remark
--
T1 after Q3 Short
T1 after Q3 Overload
--
--
T1 after Q3 Short
T1 after Q3 Overload
Verdict
--
--
--
240Vac/
60Hz
240Vac/
60Hz
10min
FS1
Amb:23.8 degree C, no
hazards.
-Model:
GT-41069P9019-T3YZ.
0.431 to 0.158 NB,NC,NT,IP(US2) (a)
10.5hr
FS1
0.490 to 0.04
--
--
--
240Vac/
60Hz
240Vac/
60Hz
10min
FS1
9.8hr
FS1
--
--
--
--
--
--
--
--
--
--
Output
Short
10min
FS1
Output
Overload
240Vac/
60Hz
240Vac/
60Hz
9hr
FS1
--
--
--
--
--
Output
Short
10min
FS1
Output
Overload
240Vac/
60Hz
240Vac/
60Hz
10.3hr
FS1
--
--
--
--
--
NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 5.44A,
T1 coil:94.6 degree C,
T1 core:90.0 degree C,
Amb:24.0 degree C, no
hazards.
-Model:
GT-41069P9024-T3YZ.
0.429 to 0.146 NB,NC,NT,IP(US2) (a)
0.562 to 0.042 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 5.05A,
T1 coil:101.0 degree C,
T1 core:96.9 degree C,
Amb:23.3 degree C, no
hazards.
5.3.6
Power Supply Output ShortCircuit/ Overload
-Model:
GT-41069P9012-T3YZ.
0.436 to 0.172 NB,NC,NT,IP(US2) (a)
0.485 to 0.041 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 8.4A,
T1 coil:102.1, degree C,
T1 core:96.5 degree C,
Amb:24.2 degree C, no
hazards.
-Model:
GT-41069P9019-T3YZ.
0.427 to 0.156 NB,NC,NT,IP(US2) (a)
0.479 to 0.041 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 5.34A,
T1 coil:99.6, degree C,
T1 core:92.1 degree C,
Amb:25.5 degree C, no
hazards.
-Model:
Issue Date:
2010-03-02
Page 11 of 11
Report Reference #
E336418-A29-UL
2010-10-22
IEC 60950-1
Clause
Requirement + Test
Output
Short
Output
Overload
240Vac/
60Hz
240Vac/
60Hz
Result - Remark
10min
FS1
10.4hr
FS1
Verdict
GT-41069P9024-T3YZ.
0.429 to 0.146 NB,NC,NT,IP(US2) (a)
0.556 to 0.043 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 4.95A,
T1 coil:100.7, degree C,
T1 core:95.5 degree C,
Amb:25.3 degree C, no
hazards.
supplementary information:
Comments Key: IP - Internal protection operated (list component). CT - Constant temperatures were obtained.
TW - Transformer winding opened. CD - Components damaged (list damaged components). NB - No indication
of dielectric breakdown. YB - Dielectric breakdown (indicate time and location). NC - Cheesecloth remained
intact. YC - Cheesecloth charred or flamed. NT - Tissue paper remained intact. YT - Tissue paper charred or
flamed. (a) - Unit shutdown instantly. (b) - Fuse open instantly. (c) - Unit operated normally and no hazard, no
damaged. Component Failure Test: Test items interrupted by the opening of Fuse (FS1) were repeated with
following source. (1) WALTER ELECTRONIC CO LTD / ICP, (2) DAS & SONS INTERNATIONAL LTD /
385T1315, (3) Conquer Electronics Co Ltd / MST, (4) SAVE FUSETECH INC / SS-5.
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 1 of 2
Report Reference #
E170507-A26-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Product Category CCN:
Test Procedure:
Product:
Model/Type Reference:
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ, QQGQ7
Listing
SWITCHING POWER ADAPTER
GT-41069PWWVV-X.X-T3YZ
Rating(s):
Where WW can be 01-90 for output power, VV can be 12 to 24 for output
voltage, X.X is optional for specifying output voltage deviations in .1 volt
increments, X.X is to be subtracted from rated voltage or blank, Y can be blank
(for C14 inlet type) or A (for C6 inlet type), Z can be 0-9, A-Z or blank for
marketing purposes only.
- Input: 100-240 Vac, 1.5 A, 50-60 Hz.
Standards:
- Output:
12 to 24 Vdc, max. 90 W for GT-41069PWWVV-X.X-T3YZ
UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology
Equipment - Safety - Part 1: General Requirements)
Applicant Name and
Address:
GLOBTEK INC
186 VETERANS DR
NORTHVALE NJ 07647
UNITED STATES
This Report includes the following parts, in addition to this cover page:
1. Specific Technical Criteria
2. Critical Components
3. Enclosures
Copyright © 2009
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 2 of 2
Report Reference #
E170507-A26-UL-1
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any
authorized licensee of UL.
Test Report By:
Reviewed By:
Wim Liang
Project Engineer
UL-CCIC Company Limited
Paul Ip
Senior Project Engineer
UL International Limited
Copyright © 2009
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 1 of 10
Report Reference #
E170507-A26-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1, First Edition
Information technology equipment - SafetyPart 1: General Requirements
Report Reference No ........................: E170507-A26-UL-1
Compiled by .....................................: Wim Liang
Reviewed by ....................................: Paul Ip
Date of issue ....................................: 2008-10-28
Standards .........................................: UL 60950-1, 1st Edition, 2007-10-31 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Test procedure .................................: Listing
Non-standard test method ...............: N/A
Test item description .......................: SWITCHING POWER ADAPTER
Trademark ........................................: None
Model and/or type reference ............: GT-41069PWWVV-X.X-T3YZ
Where WW can be 01-90 for output power, VV can be 12 to 24 for
output voltage, X.X is optional for specifying output voltage deviations
in .1 volt increments, X.X is to be subtracted from rated voltage or
blank, Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can
be 0-9, A-Z or blank for marketing purposes only.
Rating(s) ...........................................: - Input: 100-240 Vac, 1.5 A, 50-60 Hz.
- Output:
12 to 24 Vdc, max. 90 W for GT-41069PWWVV-X.X-T3YZ
Particulars: test item vs. test requirements
Equipment mobility .................................................... : movable
Operating condition ................................................... : continuous
Mains supply tolerance (%) ....................................... : +10%, -10%
Tested for IT power systems ..................................... : No
IT testing, phase-phase voltage (V) .......................... : N/A
Class of equipment ................................................... : Special Application - Functional Earthing
Mass of equipment (kg) ............................................ : 0.49 for GT-41069P9012-T Z
, GT-41069PWWVV-X.X-T3 Z; 0.46 for GT41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ.
Protection against ingress of water ........................... : IP X0
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 2 of 10
Report Reference #
E170507-A26-UL-1
Possible test case verdicts:
- test case does not apply to the test object ............. : N / A
- test object does meet the requirement ................... : Pass
- test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 3 of 10
Report Reference #
E170507-A26-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
Electronic components mounted on PWB and housed in a plastic enclosure.
CC1.0
Model Differences
CC1.1
Models GT-41069PWWVV-X.X-T3YZ are identical to each other except for transformer, output
rating, R43 rating, R46 rating, inlet type and model designation.
Where WW can be 01-90 for output power, VV can be 12 to 24 for output voltage, X.X is optional
for specifying output voltage deviations in .1 volt increments, X.X is to be subtracted from rated
voltage or blank, Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can be 0-9, A-Z or
blank for marketing purposes only.
CD1.0
Additional Information
CD1.1
Issue 1, Amendment No. 2:
Add LPS test for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.X-T3YZ.
CE1.0
Technical Considerations
CE1.2
The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40 degree C
CE1.3
The means of connection to the mains supply is: Pluggable A, Detachable power cord,
CE1.4
The product is intended for use on the following power systems: TN
CE1.5
The equipment disconnect device is considered to be: Appliance inlet,
CE1.9
The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): Output for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.XT3YZ.
CE1.14
The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual
CE1.16
The equipment employs Functional Earthing per 2.6.2. As anticipated by the NOTE for 1.2.4, it
does not conform to one of the common Classes (I, II, or III). The following insulation is provided
between the primary and accessible dead metal parts and circuits: Reinforced, Double
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 1 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.5.1
TABLE: list of critical components
Object/part No.
Manufacturer/
trademark
type/model
technical data
Product Category
CCN(s)
Label
Various
Various
PGDQ2 or PGJI2
Enclosure
--
--
--
--
- Enclosure material
SABIC INNOVATIVE SE1X
Plastics China Ltd.
Various
Various
70 degree C, if maximum
surface temperature not
specified.
Measured minimum thick 2.75
mm.
Two halves construction,
secured together by ultrasonic
welding. See enclosure 4-01
and 4-02 for dimension details.
V-1, 105 degree C, minimum
1.5 mm thick.
Detachable, limited to between
1.5 and 4.5 m long, 18 AWG,
type SVT or SPT-2, minimum
125 Vac, 10 A, with NEMA 515P or 250 Vac, 10 A. The
Other end in an appliance
coupler (with cord-connected
body, grounding type, suitable
for cord size, rating not less
than that of attachment plug)
External used wire, Jacketed.
FEP, PTFE, PVC, TFE,
Neoprene, Polyimide or marked
VW-1; FT-1, max. 3.05 m
length, 80 degree C, min. 300
V, min. 22AWG. Mechanically
secured and soldered to PWB.
Min V-1, plastic bushing
Required
Marks of
Conformity
UL
QMFZ2
UL
ZJCZ and RTRT
and AXUT, or
ELBZ
UL
ZJCZ,
AVLV2
UL
QMFZ2
UL
Power supply cord
(optional)
Output cord
Various
Various
Strain Relief for Output
Various
Various
Underwriters Laboratories Inc.
Pass
Supplement ID
4-03
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 2 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
cord
PWB
Various
Various
Appliance Inlet
SUN FAIR
ELECTRIC WIRE &
CABLE (HK) CO LTD
TECX-UNIONS
TECHNOLOGY
CORP
WALTER
ELECTRONIC CO
LTD
DAS & SONS
INTERNATIONAL
LTD
Conquer Electronics
Co Ltd
SAVE FUSETECH
INC
Various
Various
S-02
Various
NF00081
- Core
--
--
- Coil
- Triple Insulated
Winding Wire
- Tape
Various
Furukawa Electric
Co., Ltd.
Various
Appliance Inlet
(Alternate)
Fuse (FS1)
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Varistor (MOV1)
(Optional)
Line Choke (LF1)
(Optional)
Verdict
integrally molded on output
cord, see enclosure 4-03 for
details
Rated V-1 minimum, 130
degree C minimum
2.5A, 250V, 70 degree C
minimum
ZPMV2
UL
AXUT2
UL
TU-301 Series
15A, 250V, 105 degree C
minimum
AXUT2
UL
ICP
T 3.15A, 250Vac
JDYX2
UL
385T1315
T 3.15A, 250Vac
JDYX2
UL
MST
T 3.15A, 250Vac
JDYX2
UL
SS-5
T 3.15A, 250Vac
JDYX2
UL
Various
Various
JDYX
XUHT2
UL
UL
--
--
--
--
Various
TEX-E
Listed, T 3.15A, 250Vac
Rated minimum 300 Vac,
minimum 385 Vdc.
Varnished, see enclosure 4-04
for details, 130 degree C
minimum.
Ferrite, measured OD 12 mm
by 5 mm ID by 3.5 mm width
Rated minimum 130 degree C.
Rated 130 degree C.
OBMW2
OBJT2
UL
UL
Various
Rated 130 degree C.
OANZ2
UL
Underwriters Laboratories Inc.
5-01
4-04
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 3 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
- Varnish
X capcitor (CX1)
(optional)
Various
Ultra Tech Xiphi
Enterprise Co., Ltd
Various
HQX
X capcitor (CX1)
(optional) (Alternate)
TENTA ELECTRIC
INDUSTRIAL CO
LTD
CHENG TUNG
INDUSTRIAL CO
LTD
Various
MEX
--
--
X capcitor (CX1)
(optional) (Alternate)
Line Choke (LF2)
(Optional)
- Core
CTX
NF00083
- Coil
Bleeder resistor (RS1,
RS2)
Bridge Diode (BD1)
Storage Capacitor (C4)
Various
--
Various
--
---
---
PFC Choke (L1)
Various
RC00136
- Bobbin
- Core
Chang Chun Plastics T375J
Co., Ltd.
SUMITOMO
PM-9820
BAKELITE CO LTD
---
- Coil
- Tape
Various
Various
- Bobbin (Alternate)
Various
Various
Underwriters Laboratories Inc.
Verdict
Rated minimum 130 degree C.
Max. 0.47 uF, min. 250 Vac,
100 degree C, Class X1 or X2
type
Max. 0.47 uF, min. 250 Vac,
100 degree C, Class X1 or X2
type
Max. 0.47 uF, min. 250 Vac,
100 degree C, Class X1 or X2
type
See enclosure 4-05 for details,
130 degree C minimum.
Ferrite, measured OD 21.5mm
by 6 mm ID by 11 mm width
Rated minimum 130 degree C.
Each rated 1M ohm, 1/4W
SMD type, connected in series
Rated 4A, 600 V minimum
Rated 400 V, maximum 120uF,
minimum 105 degree C,
provided with integral pressure
relief
Varnished, see enclosure 4-06
for details, 130 degree C
minimum.
V-0, 150degree C, Phenolic,
thickness 0.8mm minimum
V-0, 150degree C, Phenolic,
thickness 0.71mm minimum
Ferrite, overall 32.0 by 19.5 by
30.0 mm..
Rated minimum 130 degree C.
Rated 130 degree C.
OBOR2
FOWX2
UL
UL
FOWX2
UL
FOWX2
UL
--
--
--
--
OBMW2
--
UL
--
---
---
--
--
QMFZ2
UL
QMFZ2
UL
--
--
OBMW2
OANZ2
UL
UL
4-05
4-06
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 4 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
- Varnish
Line Choke (L2)
Various
Various
Various
RC00134
- Core
--
--
- Coil
Tubing/Sleeving
Various
Great Holding
Industrial Co. Ltd.
Heat Sink (HS1)
(Primary)
Heat Sink (HS1)
(Primary) (Alternate)
Heat Sink (HS2)
(Secondary)
Heat Sink (Cover)
(Primary)
Heat Sink (Chassis)
(Primary)
Tubing (For HS1)
--
Various
TFL,
TFS,
TFT
--
--
--
--
--
--
--
--
--
CHANGYUAN
ELECTRONICS
(SHENZHEN) CO
LTD
CB-HFT
Tubing (For HS2)
CHANGYUAN
ELECTRONICS
(SHENZHEN) CO
LTD
CB-HFT
Transformer (T1) (For
Models with output 12V
GLOBTEK
XF00500
Underwriters Laboratories Inc.
Verdict
Rated minimum 130 degree C.
See enclosure 4-07 for details,
130 degree C minimum.
Ferrite, measured OD 21.5mm
by 6 mm ID by 9 mm width
Rated minimum 130 degree C.
Rated 200 degree C
OBOR2
--
UL
--
--
--
OBMW2
YDPU2
UL
UL
Aluminum material, see
-enclosure 4-08 for details
Aluminum material, see
-enclosure 4-09 for details
Aluminum material, see
-enclosure 4-10 for details
Aluminum material, see
-enclosure 4-11 for details
Aluminum material, see
-enclosure 4-12 for details
FEP, PTFE, PVC, TFE,
YDPU2
neoprene, polyimide or marked
VW-1; rated minimum 125
degree C, minimum 300 V, see
enclosure 4-08 and 4-09 for
details, thickness 0.4 mm
minimum.
FEP, PTFE, PVC, TFE,
YDPU2
neoprene, polyimide or marked
VW-1; rated minimum 125
degree C, minimum 300 V, see
enclosure 4-10 for details,
thickness 0.4 mm minimum.
See enclosure 4-15 for details --
4-07
--
4-08
--
4-09
--
4-10
--
4-11
--
4-12
UL
UL
--
4-15
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 5 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
to 15.9V.)
Transformer (T1) (For
Models with output 16V24V.)
- Insulation system for
Transformer (T1)
- Core
- Bobbin
- Bobbin (Alternate)
- Tubing/Sleeving
Result - Remark
Verdict
GLOBTEK
XF00501
See enclosure 4-16 for details
--
--
ENG Electric Co.,
Ltd.
--
ENG130-1
Class B, 130 degree C
OBJY2
UL
--
EE type, Ferrite, overall each
28.5mm by 28.5 mm by 8 mm
V-0, 150degree C, Phenolic,
thickness 0.8mm minimum
V-0, 150degree C, Phenolic,
thickness 0.71mm minimum
Rated 200 degree C
--
--
QMFZ2
UL
QMFZ2
UL
YDPU2
UL
Rated minimum 200 degree C.
Rated minimum 130 degree C.
130 degree C.
130 degree C.
OBOR2
OBOR2
OANZ2
OANZ2
UL
UL
UL
UL
Chang Chun Plastics
Co., Ltd.
SUMITOMO
BAKELITE CO LTD
Great Holding
Industrial Co. Ltd.
T375J
PM-9820
- Varnish
- Varnish (Alternate)
- Insulation Tape
- Insulation Tape
(Alternate)
- Insulation Tape
(Alternate)
- Insulation Tape
(Alternate)
- Triple Insulated
Winding Wire
Semiconductor (US1,
US2, US3)
Bridging -Capacitor
(CY1)
John C. Dolph Co.
P D George/Viking
3M Company
3M Company
TFL,
TFS,
TFT
BC-346A
V1630FS
1350T-1
1350F(#)
3M Company
44
130 degree C.
OANZ2
UL
Bondtec Pacific Co.,
Ltd.
Great Leoflon
Industrial Co., Ltd.
--
370S
130 degree C.
OANZ2
UL
TRW(B)
Rated 130 degree C.
OBJT2
UL
--
Rated 0.7A, minimum 650 V.
--
--
TDK Corp
CD
FOWX2
UL
Bridging -Capacitor
(CY1) (Alternate)
Success Electronics
Co Ltd
SE
Rated maximum 2200 pF,
minimum 250 Vac, 125 degree
C, Class Y1
Rated maximum 2200 pF,
minimum 250 Vac, 125 degree
FOWX2
UL
Underwriters Laboratories Inc.
4-16
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 6 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Bridging -Capacitor
(CY1) (Alternate)
Transistor (Q1, Q2)
Optical Isolator (U1)
Result - Remark
WALSIN
TECHNOLOGY
CORP / Pan
Overseas
-Sharp Corp.,
Electronic
Components Group
Bright LED
Electronics Corp.
Lite-On Technology
Corp.
Various
Optical Isolator (U1)
(Alternate)
Optical Isolator (U1)
(Alternate)
Internal Plastic Part
Materials
Internal Wiring (Primary) Various
AH
Verdict
C, Class Y1
Rated maximum 2200 pF,
minimum 250 Vac, 125 degree
C, Class Y1
FOWX2
UL
-PC817
Rated 10A, minimum 600 V.
Minimum 3000 Vac isolation.
Double protection.
-FPQU2
-UL
BPC-817xxxxxx
Minimum 3000 Vac isolation.
Double protection.
Minimum 3000 Vac isolation.
Double protection.
Rated V-2 minimum.
FPQU2
UL
FPQU2
UL
QMFZ2
UL
UL
---
LTV-817
Various
Various
Current sense resistor
(R1)
Current sense resistor
(R2)
Glue
--
--
FEP, PTFE, PVC, TFE,
AVLV2
neoprene, Polyimide or marked
VW-1; min. 300 V, min. 80
degree C.
0.27 ohm, 2W.
--
--
--
0.24 ohm, 2W.
Various
Various
- Tubing for Functional
Earthing
GUANGZHOU
KAIHENG
ENTERPRISE
GROUP
K-2
Insulation Tape
(between C10 and Heat
Sink (Cover))
3M Company
1350T-1
V-2 min. Components (LF1,
QMFZ2
LF2, L1, L2, C4, R1, R2,
Output cord) need
FEP, PTFE, PVC, TFE,
YDPU2
neoprene, polyimide or marked
VW-1; rated minimum 125
degree C, minimum 300 V,
thickness 0.4 mm minimum.
130 degree C.
OANZ2
Underwriters Laboratories Inc.
--
UL
UL
UL
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 7 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Insulation Tape
(between C10 and Heat
Sink (Cover)) (Alternate)
Insulation sheet
(between PWB and
Appliance Inlet)
Insulation sheet for Heat
Sink (Chassis)
Result - Remark
Verdict
Bondtec Pacific Co.,
Ltd.
370S
130 degree C.
OANZ2
UL
Various
Various
V-2 min, see Enclosure 4-13 for QMFZ2
details
UL
4-13
FORMEX,DIV OF IL
TOOL WORKS
INC,FRMRLY
FASTEX,DIV OF IL
TOOL WORKS INC
FORMEX GK
V-2 min, thickness 0.4 mm
minimum, see Enclosure 4-14
for details
UL
4-14
Underwriters Laboratories Inc.
QMFZ2
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 1 of 2
Report Reference #
Enclosure
Miscellaneous
Supplement Id
7-01
Description
Model difference
Underwriters Laboratories Inc.
E170507-A26-UL-1
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 1 of 2
Report Reference #
Enclosure
Test Record
Description
Test Record 1
Construction Review Datasheets
Test Record 2
Construction Review Datasheets
Test Record 3
CRD
Datasheet
Test Record 4
CRD
Underwriters Laboratories Inc.
E170507-A26-UL-1
Issue Date:
2008-10-28
Amendment 3
2009-08-12
Page 1 of 2
Report Reference #
E170507-A26-UL-1
Test Record No. 4
- Representing production samples of the Switching Power Adaptor, Models GT-41069PWWVV-X.XT3YZ, were submitted the manufacturer for examination and testing.
- Models of 12.1V-18.9V were added with same construction except for output voltage rating.
- No tests were considered necessary due to previous investigation.
- The results of this investigation, including construction review and testing, indicate that the products
evaluated comply with the applicable requirements in the U.S. and Canadian (Bi-National) Standard for
Safety of Information Technology Equipment-Safety-Part1: General Requirements, CAN/CSA-C22.2 No.
60950-1-03, First Edition, including revisions through revision date July 7, 2006, UL 60950-1, First Edition,
including revisions through revision date October 31, 2007, and, therefore, such products are judged
eligible to bear UL's Mark as described of this Report.
Any information and documentation involving UL Mark services are provided on behalf of Underwriters
Laboratories Inc. (UL) or any authorized licensee of UL.
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 1 of 4
Report Reference #
E170507-A26-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1, First Edition
Information technology equipment - SafetyPart 1: General Requirements
Report Reference No ........................: E170507-A26-UL-1
Compiled by .....................................: Richard Yue
Reviewed by ....................................: Wei Chen
Date of issue ....................................: 2008-10-28
Standards .........................................: UL 60950-1, 1st Edition, 2007-10-31 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Test procedure .................................: Listing
Non-standard test method ...............: N/A
Test item description .......................: SWITCHING POWER ADAPTER
Trademark ........................................: None
Model and/or type reference ............: GT-41069P9012-T3YZ
GT-41069PWWVV-X.X-T3YZ
Where WW can be 01-90 for output power, VV can be 19 to 24 for
output voltage, X.X is optional for specifying output voltage deviations
in .1 volt increments, X.X is to be subtracted from rated voltage or
blank, Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can
be 0-9, A-Z or blank for marketing purposes only.
Rating(s) ...........................................: - Input: 100-240 Vac, 1.5 A, 50-60 Hz.
- Output:
12 Vdc, 7.5 A for GT-41069P9012-T3YZ
19 to 24 Vdc, max. 90 W for GT-41069PWWVV-X.X-T3YZ
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 2 of 4
Report Reference #
E170507-A26-UL-1
Particulars: test item vs. test requirements
Equipment mobility .................................................... : movable
Operating condition ................................................... : continuous
Mains supply tolerance (%) ....................................... : +10%, -10%
Tested for IT power systems ..................................... : No
IT testing, phase-phase voltage (V) .......................... : N/A
Class of equipment ................................................... : Special Application - Functional Earthing
Mass of equipment (kg) ............................................ : 0.49 for GT-41069P9012-T Z
, GT-41069PWWVV-X.X-T3 Z; 0.46 for GT41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ.
Protection against ingress of water ........................... : IP X0
Possible test case verdicts:
- test case does not apply to the test object ............. : N / A
- test object does meet the requirement ................... : Pass
- test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 3 of 4
Report Reference #
E170507-A26-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
Electronic components mounted on PWB and housed in a plastic enclosure.
CC1.0
Model Differences
CC1.1
Models GT-41069P9012-T3YZ, GT-41069PWWVV-X.X-T3YZ are identical to each other except
for transformer, output rating, R43 rating, R46 rating, inlet type and model designation.
Where WW can be 01-90 for output power, VV can be 19 to 24 for output voltage, X.X is optional
for specifying output voltage deviations in .1 volt increments, X.X is to be subtracted from rated
voltage or blank, Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can be 0-9, A-Z or
blank for marketing purposes only.
CD1.0
Additional Information
CD1.1
Issue 1, Amendment No. 2:
Add LPS test for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.X-T3YZ.
CE1.0
Technical Considerations
CE1.2
The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40 degree C
CE1.3
The means of connection to the mains supply is: Pluggable A, Detachable power cord,
CE1.4
The product is intended for use on the following power systems: TN
CE1.5
The equipment disconnect device is considered to be: Appliance inlet,
CE1.9
The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): Output for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.XT3YZ.
CE1.14
The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual
CE1.16
The equipment employs Functional Earthing per 2.6.2. As anticipated by the NOTE for 1.2.4, it
does not conform to one of the common Classes (I, II, or III). The following insulation is provided
between the primary and accessible dead metal parts and circuits: Reinforced, Double
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 1 of 2
Report Reference #
E170507-A26-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Product Category CCN:
Test Procedure:
Product:
Model/Type Reference:
Rating(s):
Standards:
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ, QQGQ7
Listing
SWITCHING POWER ADAPTER
GT-41069P9012-T3YZ
GT-41069PWWVV-X.X-T3YZ
Where WW can be 01-90 for output power, VV can be 19 to 24 for output
voltage, X.X is optional for specifying output voltage deviations in .1 volt
increments, X.X is to be subtracted from rated voltage or blank, Y can be blank
(for C14 inlet type) or A (for C6 inlet type), Z can be 0-9, A-Z or blank for
marketing purposes only.
- Input: 100-240 Vac, 1.5 A, 50-60 Hz.
- Output:
12 Vdc, 7.5 A for GT-41069P9012-T3YZ
19 to 24 Vdc, max. 90 W for GT-41069PWWVV-X.X-T3YZ
UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology
Equipment - Safety - Part 1: General Requirements)
Applicant Name and
Address:
GLOBTEK INC
186 VETERANS DR
NORTHVALE NJ 07647
UNITED STATES
This Report includes the following parts, in addition to this cover page:
1. Specific Technical Criteria
2. Clause Verdicts
3. Enclosures
Copyright © 2009
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 2 of 2
Report Reference #
E170507-A26-UL-1
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any
authorized licensee of UL.
Test Report By:
Reviewed By:
Richard Yue
Associate Project Engineer
UL-CCIC Company Limited
Wei Chen
Associate Project Engineer
UL-CCIC Company Limited
Copyright © 2009
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 1 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
1
GENERAL
Pass
1.5
Components
Pass
1.5.1
General
Pass
1.5.2
Result - Remark
Verdict
Comply with IEC 60950 or relevant component
standard
(see appended table 1.5.1)
Pass
Evaluation and testing of components
Components certified to IEC
harmonized standard and
checked for correct
application.
Pass
Components, for which no
relevant IEC-Standard exist,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 609501 and the relevant component
Standard.
1.5.3
Thermal controls
N/A
1.5.4
Transformers
Transformers comply with the
relevant requirements of this
standard.
See annex C for compliance.
Pass
1.5.5
Interconnecting cables
Interconnecting cables comply
with the relevant requirements
of this standard.
Pass
1.5.6
Capacitors in primary circuits ................................ : - X/Y capacitors complied with
IEC 60384-14: 1993.
- Line-to-line capacitors are
subclass X1 or X2.
- Primary-to-earth capacitors
are subclass Y1.
Pass
1.5.7
Double insulation or reinforced insulation bridged
by components
Pass
1.5.7.1
General
Pass
1.5.7.2
Bridging capacitors
Double Insulation bridged by a
single capacitor complying with
IEC 60384-14: 1993, subclass
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 2 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Y1.
1.5.7.3
Bridging resistors
N/A
1.5.7.4
Accessible parts
1.5.8
Components in equipment for IT power systems
N/A
1.6
Power interface
Pass
1.6.1
AC power distribution systems
AC power distribution systems
are classified as TN.
Pass
1.6.2
Input current
The steady state input current
of the equipment did not
exceed the RATED CURRENT
by more than 10% under
NORMAL LOAD.
(see appended table 1.6.2)
Pass
1.6.3
Voltage limit of hand-held equipment
1.6.4
Neutral conductor
1.7
Marking and instructions
1.7.1
Power rating
Accessible conductive parts
separated from other parts by
DOUBLE or REINFORCED
INSULATION bridged by CY1
comply with the requirements
for LIMITED CURRENT
CIRCUITS.
Pass
N/A
The neutral conductor was
served as a line conductor.
Pass
Pass
Rating marking readily visible
to OPERATOR.
Pass
Rated voltage(s) or voltage range(s) (V) ............... : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Symbol for nature of supply, for d.c. only .............. :
N/A
Rated frequency or rated frequency range (Hz).... : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Rated current (mA or A) ........................................ : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Manufacturer's name or trademark or identification GLOBTEK INC / E170507
mark....................................................................... :
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 3 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Type/model or type reference ............................... : Refer to the Model information
at the beginning of this Test
Report.
Pass
Symbol for Class II equipment only....................... :
N/A
Other symbols ....................................................... : Additional symbols/markings
do not give rise to
misunderstanding.
Pass
Certification marks................................................. : UL and C-UL Listing Mark at
least, other certification marks
may be provided when
submitted for national
approvals.
Pass
1.7.2
Safety instructions
Pass
1.7.3
Short duty cycles
N/A
1.7.4
Supply voltage adjustment .................................... :
N/A
1.7.5
Power outlets on the equipment............................ :
N/A
1.7.6
Fuse identification.................................................. : Marking adjacent to fuse on
PWB as
FS1, T 3.15A, 250Vac.
Pass
1.7.7
Wiring terminals
N/A
1.7.7.1
Protective earthing and bonding terminals ............ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
Pass
1.7.8.1
Identification, location and marking ....................... : The function of controls
affecting safety is obvious
regardless of language.
Pass
1.7.8.2
Colours .................................................................. : A green LED is illuminated
when the unit is operating.
Pass
1.7.8.3
Symbols according to IEC 60417 .......................... :
N/A
1.7.8.4
Markings using figures........................................... :
N/A
1.7.9
Isolation of multiple power sources ....................... :
N/A
1.7.10
IT power distribution systems
N/A
1.7.11
Thermostats and other regulating devices
N/A
1.7.12
Language............................................................... : Reviewed only English
Operating/safety instructions
made available to the USER.
Underwriters Laboratories Inc.
-
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 4 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
markings/instructions.
1.7.13
Durability
All markings provided on UL
Recognized Component labels
suitable for surface they are
applied upon.
1.7.14
Removable parts
N/A
1.7.15
Replaceable batteries
N/A
Language............................................................... :
Pass
-
1.7.16
Operator access with a tool ................................... : No OPERATOR ACCESS
AREAS require the use of a
tool.
N/A
1.7.17
Equipment for restricted access locations............. : Equipment not intended for
installation in a RESTRICTED
ACCESS LOCATION.
N/A
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
2.1.1
Protection in operator access areas
Pass
2.1.1.1
Access to energized parts
The operator has access to
bare parts of SELV CIRCUITS.
Pass
Test by inspection.................................................. : The OPERATOR cannot
contact with any parts with
only BASIC INSULATION to
ELV CIRCUITS or
HAZARDOUS VOLTAGES.
Pass
Test with test finger ............................................... : The test finger was unable to
contact bare hazardous parts,
basic insulation, or ELV
circuits.
Pass
Test with test pin.................................................... : The test pin was unable to
contact bare hazardous parts.
Pass
Test with test probe ............................................... : No TNV presents.
N/A
2.1.1.2
Battery compartments ........................................... :
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (V); minimum distance (mm)
through insulation .................................................. :
2.1.1.4
Access to hazardous voltage circuit wiring
Underwriters Laboratories Inc.
N/A
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 5 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.1.1.5
Energy hazards ..................................................... : The output of the power supply
is not an energy hazard.
Pass
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
The voltage at the external
point of disconecttion did
decay to less than 37 percent
of its original value in 1.0
second.
Time-constant (s); measured voltage (V) .............. : CX1 = 0.47 uF.
Measurements taken from lineto-Neutral.
Vo (V pk) = 376 max.
37% Vo (V pk) = 139.1 max.
Vtc (V pk) = 98 max.
Verdict
Pass
-
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
2.2
SELV circuits
Pass
2.2.1
General requirements
2.2.2
Voltages under normal conditions (V) ................... : All accessible voltages are
less than 42.4V peak or 60V
dc and are classified as SELV.
Pass
2.2.3
Voltages under fault conditions (V) ....................... : Under fault conditions voltages
never exceed 71V peak and
120V dc and do not exceed
42.4V peak or 60V dc for more
than 0.2 sec.
Pass
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
Pass
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit (method
3)
N/A
2.2.4
Connection of SELV circuits to other circuits ........ : SELV CIRCUITS are only
connected to other SELV
CIRCUITS and/or LIMITED
CURRENT CIRCUITS.
Pass
SELV levels are maintained
after single fault condition.
SELV CIRCUITS are
separated from other circuits
by providing DOUBLE or
REINFORCED INSULATION
in the meaning of this
standard.
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 6 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
2.3
TNV circuits
2.3.1
Limits
2.3.2
2.3.3
Result - Remark
N/A
No TNV presents.
N/A
Type of TNV circuits .............................................. :
-
Separation from other circuits and from accessible
parts
N/A
Insulation employed............................................... :
-
Separation from hazardous voltages
N/A
Insulation employed............................................... :
2.3.4
Verdict
-
Connection of TNV circuits to other circuits
N/A
Insulation employed............................................... :
-
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
Pass
2.4.1
General requirements
The current measured
between the user accessible
part of a limited current circuit
by IEC leakage current meter.
Conducted on bridging
capacitor CY1.
Pass
2.4.2
Limit values
0.7 mA peak.
Pass
Frequency (Hz)...................................................... : 60 Hz
-
Measured current (mA).......................................... : 0.165 MIU maximum.
-
Measured voltage (V) ............................................ : 354 V peak maximum.
-
Measured capacitance (mF).................................. : CY1: 2200 pF.
-
2.4.3
Connection of limited current circuits to other
circuits
The LIMITED CURRENT
CIRCUIT connected to other
circuits complies with the
requirements of Sub-clause
2.4.1.
2.5
Limited power sources
Pass
Inherently limited output
Pass
Impedance limited output
N/A
Underwriters Laboratories Inc.
N/A
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 7 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Overcurrent protective device limited output
N/A
Regulating network limited output under normal
operating and single fault condition
Pass
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
For Model GT-41069P9012power (VA):............................................................ : T3YZ:
Uoc = 12.2 V, Isc = 8.0 A, VA
= 96 VA.
For model GT-41069P90243.75-T3YZ:
Uoc = 24.2 V, Isc = 4.0 A, VA
= 96 VA..
-
Current rating of overcurrent protective device (A) :
-
2.6
Provisions for earthing and bonding
Pass
2.6.1
Protective earthing
N/A
2.6.2
Functional earthing
2.6.3
Protective earthing and protective bonding
conductors
Pass
2.6.3.1
General
Pass
2.6.3.2
Size of protective earthing conductors
Functional earthing separated
from Hazardous voltage by
reinforced insulation.
Functional Earthing connected
to protective bonding.
Insulation on functional
earthing conductor is not
green-yellow.
Power supply cord earthing
conductor complies with Table
3B (Optional provided).
Rated current (A), cross-sectional area (mm2),
(See appended table 1.5.1)
AWG ...................................................................... :
2.6.3.3
2.6.3.4
Size of protective bonding conductors
Only functional Earthing
provided.
Pass
Pass
N/A
Rated current (A), cross-sectional area (mm2),
AWG ...................................................................... :
-
Resistance (Ohm) of earthing conductors and their
terminations, test current (A) ................................. :
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 8 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.6.3.5
Colour of insulation................................................ :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
Verdict
-
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
Pass
2.7.1
Basic requirements
Protection provided as part of
the building installation.
Pass
Instructions when protection relies on building
installation
Pluggable Type A.
Pass
2.7.2
Faults not covered in 5.3
Protection from faults not
covered in 5.3 are provided by
installation.
Pass
2.7.3
Short-circuit backup protection
The building installation is
considered as providing shortcircuit backup protection for
PLUGGABLE EQUIPMENT
TYPE A.
Pass
2.7.4
Number and location of protective devices ........... : One protective device in the
"LIVE" phase
Pass
2.7.5
Protection by several devices
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 9 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
2.7.6
Warning to service personnel ................................ : No protective device is
provided in the neutral
conductor.
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ................................................ :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
Pass
2.9.1
Properties of insulating materials
Natural rubber, materials
containing asbestos and
hygroscopic materials are not
used as insulation.
Pass
2.9.2
Humidity conditioning
The humidity treatment was
conducted for 48 hrs.
Electric strength test was
conducted after the humidity
treatment.
Pass
2.9.3
Result - Remark
No SAFETY INTERLOCKS
used.
Verdict
N/A
Humidity (%) .......................................................... : 95
-
Temperature (°C)................................................... : 30
-
Grade of insulation
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 10 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.10
Clearances, creepage distances and distances through insulation
Pass
2.10.1
General
Pass
Pollution degree 2 applicable.
Verdict
FUNCTIONAL INSULATION
complied with Sub-clause
5.3.4.
2.10.2
Determination of working voltage
Pass
2.10.3
Clearances
2.10.3.1
General
2.10.3.2
Clearances in primary circuit
(see appended table 2.10.3
and 2.10.4).
Pass
2.10.3.3
Clearances in secondary circuits
Functional insulation only.
Waived by short circuit fault
test per Sub-clause 5.3.4.
Pass
2.10.3.4
Measurement of transient voltage levels
2.10.4
Creepage distances
(see appended table 2.10.3
and 2.10.4).
Pass
Pass
N/A
(see appended table 2.10.3
and 2.10.4).
CTI tests ................................................................ : Material Group IIIb assumed
unless otherwise indicated.
100 <= CTI < 175
Pass
-
2.10.5
Solid insulation
Solid or laminated insulating
materials having adequate
thickness are provided.
Pass
2.10.5.1
Minimum distance through insulation
See Table 2.10.5
Pass
2.10.5.2
Thin sheet material
Two layers used, each of
which complies with the
required electric strength test
(see appended table 5.2)
Pass
2.10.5.3
2.10.5.4
Number of layers (pcs) .......................................... : Reinforced Insulation - 2
layers
-
Electric strength test .............................................. : (see appended table 5.2)
-
Printed boards
N/A
Distance through insulation
N/A
Electric strength test for thin sheet insulating
material .................................................................. :
-
Number of layers (pcs) .......................................... :
N/A
Wound components
The employed UL Recognized
wiring meets the requirements
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 11 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
of 2.10.5.4 and Annex U.
Number of layers (pcs) .......................................... : Three extruded layers.
Pass
Two wires in contact inside wound component;
Physical separation in the form
angle between 45° and 90° ................................... : of insulating sleeving provided
to relieve mechanical stress at
the crossover point.
Pass
2.10.6
Coated printed boards
N/A
2.10.6.1
General
N/A
2.10.6.2
Sample preparation and preliminary inspection
N/A
2.10.6.3
Thermal cycling
N/A
2.10.6.4
Thermal ageing (°C) .............................................. :
N/A
2.10.6.5
Electric strength test .............................................. :
-
2.10.6.6
Abrasion resistance test
2.10.7
2.10.8
N/A
Electric strength test .............................................. :
-
Enclosed and sealed parts .................................... :
N/A
Temperature T1=T2 = Tma - Tamb +10K (°C)...... :
N/A
Spacings filled by insulating compound ................ : Approved Optical Isolator
used.
Pass
Electric strength test .............................................. : (see appended table 2.10.5)
-
2.10.9
Component external terminations
N/A
2.10.10
Insulation with varying dimensions
N/A
3
WIRING, CONNECTIONS AND SUPPLY
Pass
3.1
General
Pass
3.1.1
Current rating and overcurrent protection
All internal wires and
INTERCONNECTING
CABLES possess adequate
cross-sectional areas for their
intended application and all
internal wirings are adequately
insulated.
Pass
3.1.2
Protection against mechanical damage
The wires are routed away
from sharp edges and parts
which could damage
insulation.
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 12 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
3.1.3
Securing of internal wiring
Internal wiring routed,
supported, clamped or secured
in a manner that excessive
strain on wire and on terminal
connections, loosening of
terminal connections and
damage of conductor
insulation are unlikely.
Pass
3.1.4
Insulation of conductors
The insulation of the individual
conductors is suitable for the
application and the working
voltage.
Pass
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
N/A
3.1.9
Termination of conductors
Pass
10 N pull test
Pass
The sleeving used as
supplementary insulation on
internal wiring is retained by
positive means.
Verdict
3.1.10
Sleeving on wiring
3.2
Connection to an a.c. mains supply or a d.c. mains supply
Pass
3.2.1
Means of connection
Pass
3.2.1.1
Connection to an a.c. mains supply
Pass
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
The unit is provided with an
appliance inlet.
Number of conductors, diameter (mm) of cable and
conduits ................................................................. :
3.2.4
Appliance inlets
Pass
The appliance inlet complies
with IEC 60320.
Appliance inlet can be inserted
without difficulty and so placed
that, after insertion of the
connector, the equipment is
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 13 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
not supported by the connector
for any position of normal use
on a flat surface.
3.2.5
Power supply cords
Power supply cord suitable for
application and subject to
country's national code and
regulations to be provided by
the manufacturer.
(Optional provided).
Pass
3.2.5.1
AC power supply cords
(Optional provided).
Pass
Type....................................................................... : (See appended table 1.5.1)
-
Rated current (A), cross-sectional area (mm²),
(See appended table 1.5.1)
AWG ...................................................................... :
-
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
Strain Relief provided for
output cord.
Pass
Mass of equipment (kg), pull (N) ........................... : Equipment 0.49 kg maximum.
30 N pulling force was applied.
-
Longitudinal displacement (mm) ........................... : 0.6 mm maximum.
-
3.2.7
Protection against mechanical damage
3.2.8
Cord guards
Cord not exposed to sharp
points or edges.
Pass
N/A
D (mm); test mass (g)............................................ :
-
Radius of curvature of cord (mm).......................... :
-
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
The equipment is not
permanently connected or
provided with a nondetachable power supply cord.
Rated current (A), cord/cable type, cross-sectional
area (mm²) ............................................................. :
Underwriters Laboratories Inc.
-
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 14 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
3.3.5
Wiring terminal sizes
Result - Remark
Verdict
N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
-
3.3.6
Wiring terminals design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
Pass
3.4.1
General requirement
Pass
3.4.2
Disconnect devices
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
No isolating switches fitted in
flexible cords.
N/A
3.4.6
Single-phase equipment and d.c. equipment
Disconnect device disconnects
all poles simultaneously.
Pass
3.4.7
Three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
Pass
3.5.1
General requirements
3.5.2
Types of interconnection circuits ........................... : Interconnection circuits are
SELV CIRCUITS/LIMITED
CURRENT CIRCUITS.
Pass
3.5.3
ELV circuits as interconnection circuits
N/A
The Appliance Inlet is used as
the disconnect device.
Interconnection circuit did
continued conformance to the
requirements of SELV
CIRCUITS.
Underwriters Laboratories Inc.
Pass
Pass
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 15 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
4
PHYSICAL REQUIREMENTS
Pass
4.1
Stability
N/A
Angle of 10°
Based on construction review,
the test was deemed not
necessary.
Verdict
N/A
Test: force (N)........................................................ :
N/A
4.2
Mechanical strength
Pass
4.2.1
General
Pass
4.2.2
Steady force test, 10 N
Pass
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
4.2.5
Impact test
No hazards as a result of the
250 N test.
Pass
Pass
Fall test
500 g steel sphere ball fall
from 1.3 m height onto the
enclosure, there are no safety
relevant damages.
Pass
Swing test
N/A
4.2.6
Drop test
N/A
4.2.7
Stress relief test
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
N/A
4.3
Design and construction
Pass
4.3.1
Edges and corners
4.3.2
Handles and manual controls; force (N)................ :
No indication of shrinkage or
distortion on enclosures due to
the stress relief test ( 101.3
degree C/7 h).
All edges and corners judged
to be sufficiently well rounded
so as not to constitute a
hazard.
Underwriters Laboratories Inc.
Pass
Pass
N/A
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 16 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
4.3.3
Adjustable controls
4.3.4
Securing of parts
No loosening of parts impairing
creepage distances or
clearances over
supplementary or reinforced
insulation is likely to occur.
Pass
4.3.5
Connection of plugs and sockets
The equipment does not have
any interchangeable
plugs/sockets.
Pass
4.3.6
Direct plug-in equipment
N/A
Dimensions (mm) of mains plug for direct plug-in . :
N/A
Torque and pull test of mains plug for direct plug-in;
torque (Nm); pull (N).............................................. :
N/A
4.3.7
Heating elements in earthed equipment
N/A
4.3.8
Batteries
N/A
4.3.9
Oil and grease
N/A
4.3.10
Dust, powders, liquids and gases
N/A
4.3.11
Containers for liquids or gases
N/A
4.3.12
Flammable liquids.................................................. :
N/A
Quantity of liquid (l)................................................ :
N/A
Flash point (°C)...................................................... :
N/A
4.3.13
Radiation; type of radiation
Pass
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
4.3.13.3
Result - Remark
Verdict
N/A
Measured radiation (pA/kg) ................................... :
-
Measured high-voltage (kV) .................................. :
-
Measured focus voltage (kV)................................. :
-
CRT markings........................................................ :
-
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification .......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ....... :
N/A
4.3.13.5
Laser (including LEDs)
This product contains only
visible indicator LEDs (Class
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 17 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1). No IEC60825-1 evaluation
was deemed necessary.
Additional review may be
required at the discretion of the
accepting NCB.
Laser class ............................................................ : (For indicator LEDs, see above
statement.)
-
4.3.13.6
Other types ............................................................ :
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
Pass
4.5.1
Maximum temperatures
No hazardous moving part
presents.
The equipment and its
components did not attain
excessive temperatures during
normal operation.
(see appended table 4.5)
N/A
Pass
Normal load condition per Annex L ....................... : Operated in the most
unfavorable way of operation
given in the operating
instructions until steady
conditions established.
Pass
4.5.2
Resistance to abnormal heat
N/A
4.6
Openings in enclosures
Pass
4.6.1
Top and side openings
Pass
Dimensions (mm) .................................................. : No openings.
4.6.2
Bottoms of fire enclosures
Construction of the bottom .................................... : No openings.
4.6.3
Doors or covers in fire enclosures
Underwriters Laboratories Inc.
Pass
N/A
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 18 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
4.6.4
Openings in transportable equipment
No openings.
4.6.5
Adhesives for constructional purposes
Verdict
Pass
N/A
Conditioning temperature (°C)/time (weeks) ......... :
-
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Pass
Method 1, selection and application of components Method 1: Selection and
wiring and materials
application of components and
materials which minimize the
possibility of ignition and
spread of flame.
Pass
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Pass
4.7.2.1
Parts requiring a fire enclosure
A fire enclosure covers all
parts except as noted in
4.7.2.2.
Pass
4.7.2.2
Parts not requiring a fire enclosure
Plugs and connectors forming
part of a power supply cord or
interconnecting cable.
Pass
4.7.3
Materials
4.7.3.1
General
The propagation of fire is
minimized through satisfying
the requirement of
constructions and materials.
Pass
4.7.3.2
Materials for fire enclosures
Equipment is moveable with
mass less than 18 kg. Fire
enclosure material is V-1
minimum
Pass
4.7.3.3
Materials for components and other parts outside
fire enclosures
Pass
4.7.3.4
Materials for components and other parts inside fire PWBs are rated min. V-1.
enclosures
All internal materials are rated
V-2 or better or are mounted
on a PWB rated V-1 or better
Internal wiring is UL
Recognized, marked VW-1 or
FT-1 and strapped by
individual cable ties (where
needed).
Pass
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 19 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
See Table 1.5.1 for material
information.
4.7.3.5
Materials for air filter assemblies
N/A
4.7.3.6
Materials used in high-voltage components
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
Pass
5.1.1
General
Pass
5.1.2
Equipment under test (EUT)
Equipment designed for
connection to only one power
source.
Pass
5.1.3
Test circuit
Figure 5A.
Single phase equipment
intended only for connection to
TN system.
Pass
5.1.4
Application of measuring instrument
Using the measuring
instrument specified in annex
D.1.
Test made to 10 x 20 cm metal
foil in contact with accessible
non-conductive part.
Pass
5.1.5
Test procedure
Pass
5.1.6
Test measurements
Pass
Test voltage (V) ..................................................... : 264V/60Hz
-
Measured touch current (mA)................................ : Max. 0.165 mA measured at
output (-) as "e" open.
Max. 0.004 mA measured at
Enclosure with foil as "e"
closed.
-
Max. allowed touch current (mA)........................... : 0.25 mA for Accessible plastic
enclosure.
3.5 mA for output (-) and
output (+).
-
Measured protective conductor current (mA) ........ : --
-
Max. allowed protective conductor current (mA) ... : --
-
5.1.7
Equipment with touch current exceeding 3.5 mA .. :
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and from
N/A
No TNV presents.
Underwriters Laboratories Inc.
N/A
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 20 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
telecommunication networks
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable distribution
system
N/A
Test voltage (V) ..................................................... :
-
Measured touch current (mA)................................ :
-
Max. allowed touch current (mA)........................... :
-
5.1.8.2
Summation of touch currents from
telecommunication networks ................................. :
N/A
5.2
Electric strength
Pass
5.2.1
General
Based on the electric strength
test the use of the insulating
materials within the equipment
is satisfactory.
Pass
5.2.2
Test procedure
No insulation breakdown
detected during the test.
(See Table 5.2 for details)
Pass
5.3
Abnormal operating and fault conditions
5.3.1
Protection against overload and abnormal
operation
5.3.2
Motors
5.3.3
Transformers
Transformers are constructed
in accordance with the
applicable Clause and Annex
C.
(see appended Annex C)
Pass
5.3.4
Functional insulation.............................................. : Functional insulation complies
with the requirements (c).
Pass
5.3.5
Electromechanical components
N/A
5.3.6
Simulation of faults
5.3.7
Unattended equipment
5.3.8
Compliance criteria for abnormal operating and
fault conditions
Pass
(see appended table 5.3)
Pass
N/A
(see appended table 5.3)
Pass
N/A
No fire, emission of molten
metal, deformation, excessive
temperature rises or insulation
breakdown was detected
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 21 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
during these tests.
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Test voltage (V) ..................................................... :
-
Current in the test circuit (mA)............................... :
-
6.1.2.2
Exclusions ............................................................. :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A).......................................... :
-
Current limiting method ......................................... :
-
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
Protection of cable distribution system service persons, and users of other
equipment connected to the system, from hazardous voltages in the equipment
N/A
7.2
Protection of equipment users from overvoltages
on the cable distribution system
N/A
7.3
Insulation between primary circuits and cable
distribution systems
N/A
7.3.1
General
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 22 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
7.3.2
Voltage surge test
N/A
7.3.3
Impulse test
N/A
A
Annex A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples................................................................. :
-
Wall thickness (mm) .............................................. :
-
A.1.2
Conditioning of samples; temperature (°C) ........... :
N/A
A.1.3
Mounting of samples ............................................. :
N/A
A.1.4
Test flame
N/A
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s) ..................................... :
-
Sample 2 burning time (s) ..................................... :
-
Sample 3 burning time (s) ..................................... :
-
N/A
A.2
Flammability test for fire enclosures of movable equipment having a total
mass not exceeding 18 kg, and for material and components located inside
fire enclosures (see 4.7.3.2 and 4.7.3.4)
A.2.1
Samples, material.................................................. :
-
Wall thickness (mm) .............................................. :
-
A.2.2
Conditioning of samples
N/A
A.2.3
Mounting of samples
N/A
A.2.4
Test flame
N/A
A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
A.2.7
Sample 1 burning time (s) ..................................... :
-
Sample 2 burning time (s) ..................................... :
-
Sample 3 burning time (s) ..................................... :
-
Alternative test acc. to IEC 60695-2-2, cl. 4, 8
Underwriters Laboratories Inc.
N/A
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 23 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Sample 1 burning time (s) ..................................... :
-
Sample 2 burning time (s) ..................................... :
-
Sample 3 burning time (s) ..................................... :
-
A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
A.3.3
Compliance criterion
N/A
B
Annex B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and
5.3.2)
N/A
B.1
General requirements
N/A
Position .................................................................. :
-
Manufacturer ......................................................... :
-
Type....................................................................... :
-
Rated values.......................................................... :
-
B.2
Test conditions
N/A
B.3
Maximum temperatures
N/A
B.4
Running overload test
N/A
B.5
Locked-rotor overload test
N/A
Test duration (days)............................................... :
-
Electric strength test: test voltage (V).................... :
-
B.6
Running overload test for d.c. motors in secondary
circuits
N/A
B.7
Locked-rotor overload test for d.c. motors in secondary circuits
N/A
B.7.1
Test procedure
N/A
B.7.2
Alternative test procedure; test time (h) ................ :
N/A
B.7.3
Electric strength test
N/A
B.8
Test for motors with capacitors
N/A
B.9
Test for three-phase motors
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 24 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
B.10
Test for series motors
C
Result - Remark
Verdict
N/A
Operating voltage (V) ............................................ :
-
Annex C, TRANSFORMERS (see 1.5.4 and 5.3.3)
Pass
Position .................................................................. : T1.
-
Manufacturer ......................................................... : (See Table 1.5.1)
-
Type....................................................................... : (See Table 1.5.1)
-
Rated values.......................................................... : (See Table 1.5.1)
-
Method of protection.............................................. : Regulation network provided.
-
C.1
Overload test
(see appended table 5.3)
Pass
C.2
Insulation
(see appended table 5.2)
Pass
Protection from displacement of windings............. : Triple insulated wire used.
Pass
D
Annex D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
Pass
D.1
Measuring instrument
Pass
D.2
Alternative measuring instrument
N/A
E
Annex E, TEMPERATURE RISE OF A WINDING
N/A
F
Annex F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10)
Pass
G
Annex G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
G.1
Summary of the procedure for determining
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)
N/A
G.2.1
AC mains supply
N/A
G.2.2
DC mains supply
N/A
Using the measuring
instrument specified in annex
D.1.
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 25 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
G.3
Determination of telecommunication network
transient voltage (V) : ............................................ :
N/A
G.4
Determination of required withstand voltage (V) ... :
N/A
G.5
Measurement of transient levels (V)...................... :
N/A
G.6
Determination of minimum clearances .................. :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
Annex J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
Metal used ............................................................. :
Verdict
-
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V).......... :
N/A
K.3
Thermostat endurance test; operating voltage (V) :
N/A
K.4
Temperature limiter endurance; operating voltage
(V) .......................................................................... :
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
N/A
L
Annex L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
Pass
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
L.7
Other business equipment
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 26 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
M
Annex M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz)...................................................... :
-
M.3.1.2
Voltage (V)............................................................. :
-
M.3.1.3
Cadence; time (s), voltage (V)............................... :
-
M.3.1.4
Single fault current (mA)........................................ :
-
M.3.2
Tripping device and monitoring voltage................. :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V) ........................................... :
N/A
N
Annex N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and
clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
Annex P, NORMATIVE REFERENCES
Pass
Q
Annex Q, BIBLIOGRAPHY
Pass
R
Annex R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
Annex S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
Underwriters Laboratories Inc.
Verdict
Issue Date:
2008-10-28
Amendment 2
2009-03-23
Page 27 of 27
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
Annex T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see
1.1.2)
N/A
............................................................................... :
U
Annex U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
............................................................................... : Used of three layers of
extruded insulation wire were
approved. (See append table
1.5.1)
Underwriters Laboratories Inc.
Verdict
-
Pass
-
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 1 of 2
Report Reference #
E170507-A26-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Product Category CCN:
Test Procedure:
Product:
Model/Type Reference:
Rating(s):
Standards:
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ, QQGQ7
Listing
SWITCHING POWER ADAPTER
GT-41069P9012-T3YZ
GT-41069PWWVV-X.X-T3YZ
Where WW can be 01-90 for output power, VV can be 19 to 24 for output
voltage, X.X is optional for specifying output voltage deviations in .1 volt
increments, X.X is to be subtracted from rated voltage or blank, Y can be blank
(for C14 inlet type) or A (for C6 inlet type), Z can be 0-9, A-Z or blank for
marketing purposes only.
- Input: 100-240 Vac, 1.5 A, 50-60 Hz.
- Output:
12 Vdc, 7.5 A for GT-41069P9012-T3YZ
19 to 24 Vdc, max. 90 W for GT-41069PWWVV-X.X-T3YZ
UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology
Equipment - Safety - Part 1: General Requirements)
Applicant Name and
Address:
GLOBTEK INC
186 VETERANS DR
NORTHVALE NJ 07647
UNITED STATES
This Report includes the following parts, in addition to this cover page:
1. Specific Technical Criteria
2. Critical Components
3. Test Results
4. Enclosures
Copyright © 2008
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 2 of 2
Report Reference #
E170507-A26-UL-1
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any
authorized licensee of UL.
Test Report By:
Reviewed By:
Glenn Wang
Senior Project Engineer
Underwriters Laboratories of Canada
Joseph Petilla
Engineering Team Leader
Underwriters Laboratories of Canada
Copyright © 2008
Issue Date:
2008-10-28
Page 1 of 54
Report Reference #
E170507-A26-UL-1
SPECIFIC INSPECTION CRITERIA
BA1.0
Special Instructions to UL Representative
BA1.1
N/A
BB1.0
Supporting Documentation
BB1.1
The following documents located at the beginning of this Procedure supplement the requirements
of this Test Report:
A. Authorization - The Authorization page may include additional Factory Identification Code
markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this
Procedure. Products described in this Test Report must comply with any applicable items
listed unless otherwise stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this
Procedure. Products described in this Test Report must comply with any applicable items
listed unless otherwise stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the
technical standard used to investigate these products. Products are permitted to bear only
the Certification Mark(s) corresponding to the countries for which it is certified, as indicated
in each Test Report.
BC1.0
Markings and instructions
BC1.1
The following markings and instructions are provided as indicated.
BC1.2
All clause references are from UL 60950-1, 1st Edition, 2007-10-31 (Information Technology
Equipment - Safety - Part 1: General Requirements).
Standard
Clause
Clause Title
Marking or Instruction Details
1.7.1
Power rating Ratings
Ratings (voltage, frequency/dc, current)
Power rating Company
identification
Listee's or Recognized company's name, Trade Name, Trademark or File
Number
Power rating Model
Model Number
Fuses - Rating
Rated current and voltage and type located on or adjacent to fuse or
fuseholder.
1.7.6
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 2 of 54
Report Reference #
E170507-A26-UL-1
BD1.0
Production-Line Testing Requirements
BD1.1
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Test
Potential
Model
Component
Removable Parts
Test probe location
All models
T1
--
Primary to Secondary
BD1.2
Earthing Continuity Test Exemptions - This
test is not required for the following models:
BD1.3
Electric Strength Test Exemptions - This test
is not required for the following models:
BD1.4
Electric Strength Test Component
Exemptions - The following solid-state
components may be disconnected from the
remainder of the circuitry during the
performance of this test:
BE1.0
Sample and Test Specifics for Follow-Up Tests at UL
BE1.1
Model
Component
Material
Test
N/A
Underwriters Laboratories Inc.
V
Test
rms V dc Time, s
3000
Sample(s)
--
1
Test
Specifics
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 1 of 12
Report Reference #
E170507-A26-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1, First Edition
Information technology equipment - SafetyPart 1: General Requirements
Report Reference No ........................: E170507-A26-UL-1
Compiled by .....................................: Glenn Wang
Reviewed by ....................................: Joseph Petilla
Date of issue ....................................: 2008-10-28
Standards .........................................: UL 60950-1, 1st Edition, 2007-10-31 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Test procedure .................................: Listing
Non-standard test method ...............: N/A
Test item description .......................: SWITCHING POWER ADAPTER
Trademark ........................................: None
Model and/or type reference ............: GT-41069P9012-T3YZ
GT-41069PWWVV-X.X-T3YZ
Where WW can be 01-90 for output power, VV can be 19 to 24 for
output voltage, X.X is optional for specifying output voltage deviations
in .1 volt increments, X.X is to be subtracted from rated voltage or
blank, Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can
be 0-9, A-Z or blank for marketing purposes only.
Rating(s) ...........................................: - Input: 100-240 Vac, 1.5 A, 50-60 Hz.
- Output:
12 Vdc, 7.5 A for GT-41069P9012-T3YZ
19 to 24 Vdc, max. 90 W for GT-41069PWWVV-X.X-T3YZ
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 2 of 12
Report Reference #
E170507-A26-UL-1
Particulars: test item vs. test requirements
Equipment mobility .................................................... : movable
Operating condition ................................................... : continuous
Mains supply tolerance (%) ....................................... : +10%, -10%
Tested for IT power systems ..................................... : No
IT testing, phase-phase voltage (V) .......................... : N/A
Class of equipment ................................................... : Special Application - Functional Earthing
Mass of equipment (kg) ............................................ : 0.49 for GT-41069P9012-T Z
, GT-41069PWWVV-X.X-T3 Z; 0.46 for GT41069P9012-T3AZ,
GT-41069PWWVV-X.X-T3AZ.
Protection against ingress of water ........................... : IP X0
Possible test case verdicts:
- test case does not apply to the test object ............. : N / A
- test object does meet the requirement ................... : Pass
- test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 3 of 12
Report Reference #
E170507-A26-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
Electronic components mounted on PWB and housed in a plastic enclosure.
CC1.0
Model Differences
CC1.1
Models GT-41069P9012-T3YZ, GT-41069PWWVV-X.X-T3YZ are identical to each other except
for transformer, output rating, R43 rating, R46 rating, inlet type and model designation.
Where WW can be 01-90 for output power, VV can be 19 to 24 for output voltage, X.X is optional
for specifying output voltage deviations in .1 volt increments, X.X is to be subtracted from rated
voltage or blank, Y can be blank (for C14 inlet type) or A (for C6 inlet type), Z can be 0-9, A-Z or
blank for marketing purposes only.
CD1.0
Additional Information
CD1.1
N/A
CE1.0
Technical Considerations
CE1.2
The product was submitted and tested for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40 degree C
CE1.3
The means of connection to the mains supply is: Pluggable A, Detachable power cord,
CE1.4
The product is intended for use on the following power systems: TN
CE1.5
The equipment disconnect device is considered to be: Appliance inlet,
CE1.14
The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual
CE1.16
The equipment employs Functional Earthing per 2.6.2. As anticipated by the NOTE for 1.2.4, it
does not conform to one of the common Classes (I, II, or III). The following insulation is provided
between the primary and accessible dead metal parts and circuits: Reinforced, Double
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 6 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
1
GENERAL
Pass
1.5
Components
Pass
1.5.1
General
Pass
1.5.2
Result - Remark
Verdict
Comply with IEC 60950 or relevant component
standard
(see appended table 1.5.1)
Pass
Evaluation and testing of components
Components certified to IEC
harmonized standard and
checked for correct
application.
Pass
Components, for which no
relevant IEC-Standard exist,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 609501 and the relevant component
Standard.
1.5.3
Thermal controls
N/A
1.5.4
Transformers
Transformers comply with the
relevant requirements of this
standard.
See annex C for compliance.
Pass
1.5.5
Interconnecting cables
Interconnecting cables comply
with the relevant requirements
of this standard.
Pass
1.5.6
Capacitors in primary circuits ................................ : - X/Y capacitors complied with
IEC 60384-14: 1993.
- Line-to-line capacitors are
subclass X1 or X2.
- Primary-to-earth capacitors
are subclass Y1.
Pass
1.5.7
Double insulation or reinforced insulation bridged
by components
Pass
1.5.7.1
General
Pass
1.5.7.2
Bridging capacitors
Double Insulation bridged by a
single capacitor complying with
IEC 60384-14: 1993, subclass
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Page 7 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Y1.
1.5.7.3
Bridging resistors
N/A
1.5.7.4
Accessible parts
1.5.8
Components in equipment for IT power systems
N/A
1.6
Power interface
Pass
1.6.1
AC power distribution systems
AC power distribution systems
are classified as TN.
Pass
1.6.2
Input current
The steady state input current
of the equipment did not
exceed the RATED CURRENT
by more than 10% under
NORMAL LOAD.
(see appended table 1.6.2)
Pass
1.6.3
Voltage limit of hand-held equipment
1.6.4
Neutral conductor
Accessible conductive parts
separated from other parts by
DOUBLE or REINFORCED
INSULATION bridged by CY1
comply with the requirements
for LIMITED CURRENT
CIRCUITS.
Pass
N/A
The neutral conductor was
served as a line conductor.
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Page 8 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
1.7
Marking and instructions
1.7.1
Power rating
Verdict
Pass
Rating marking readily visible
to OPERATOR.
Pass
Rated voltage(s) or voltage range(s) (V) ............... : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Symbol for nature of supply, for d.c. only .............. :
N/A
Rated frequency or rated frequency range (Hz).... : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Rated current (mA or A)......................................... : Refer to the Rating information
at the beginning of this Test
Report.
Pass
Manufacturer's name or trademark or identification GLOBTEK INC / E170507
mark ....................................................................... :
Pass
Type/model or type reference................................ : Refer to the Model information
at the beginning of this Test
Report.
Pass
Symbol for Class II equipment only ....................... :
N/A
Other symbols........................................................ : Additional symbols/markings
do not give rise to
misunderstanding.
Pass
Certification marks ................................................. : UL and C-UL Listing Mark at
least, other certification marks
may be provided when
submitted for national
approvals.
Pass
1.7.2
Safety instructions
Pass
1.7.3
Short duty cycles
N/A
1.7.4
Supply voltage adjustment..................................... :
N/A
1.7.5
Power outlets on the equipment ............................ :
N/A
1.7.6
Fuse identification.................................................. : Marking adjacent to fuse on
PWB as
FS1, T 3.15A, 250Vac.
Pass
1.7.7
Wiring terminals
N/A
1.7.7.1
Protective earthing and bonding terminals ............ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
Operating/safety instructions
made available to the USER.
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 9 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
Pass
1.7.8.1
Identification, location and marking ....................... : The function of controls
affecting safety is obvious
regardless of language.
Pass
1.7.8.2
Colours................................................................... : A green LED is illuminated
when the unit is operating.
Pass
1.7.8.3
Symbols according to IEC 60417 .......................... :
N/A
1.7.8.4
Markings using figures........................................... :
N/A
1.7.9
Isolation of multiple power sources ....................... :
N/A
1.7.10
IT power distribution systems
N/A
1.7.11
Thermostats and other regulating devices
N/A
1.7.12
Language............................................................... : Reviewed only English
markings/instructions.
1.7.13
Durability
1.7.14
Removable parts
N/A
1.7.15
Replaceable batteries
N/A
All markings provided on UL
Recognized Component labels
suitable for surface they are
applied upon.
Language............................................................... :
Verdict
Pass
-
1.7.16
Operator access with a tool ................................... : No OPERATOR ACCESS
AREAS require the use of a
tool.
N/A
1.7.17
Equipment for restricted access locations ............. : Equipment not intended for
installation in a RESTRICTED
ACCESS LOCATION.
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 10 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
2.1.1
Protection in operator access areas
Pass
2.1.1.1
Access to energized parts
The operator has access to
bare parts of SELV CIRCUITS.
Verdict
Pass
Test by inspection.................................................. : The OPERATOR cannot
contact with any parts with
only BASIC INSULATION to
ELV CIRCUITS or
HAZARDOUS VOLTAGES.
Pass
Test with test finger................................................ : The test finger was unable to
contact bare hazardous parts,
basic insulation, or ELV
circuits.
Pass
Test with test pin.................................................... : The test pin was unable to
contact bare hazardous parts.
Pass
Test with test probe ............................................... : No TNV presents.
N/A
2.1.1.2
Battery compartments............................................ :
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (V); minimum distance (mm)
through insulation .................................................. :
-
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards...................................................... : The output of the power supply
is not an energy hazard.
Pass
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
The voltage at the external
point of disconecttion did
decay to less than 37 percent
of its original value in 1.0
second.
Time-constant (s); measured voltage (V) .............. : CX1 = 0.47 uF.
Measurements taken from lineto-Neutral.
Vo (V pk) = 376 max.
37% Vo (V pk) = 139.1 max.
Vtc (V pk) = 98 max.
Pass
-
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 11 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
2.2
SELV circuits
2.2.1
General requirements
2.2.2
Voltages under normal conditions (V) ................... : All accessible voltages are
less than 42.4V peak or 60V
dc and are classified as SELV.
Pass
2.2.3
Voltages under fault conditions (V)........................ : Under fault conditions voltages
never exceed 71V peak and
120V dc and do not exceed
42.4V peak or 60V dc for more
than 0.2 sec.
Pass
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
Pass
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit (method
3)
N/A
2.2.4
Connection of SELV circuits to other circuits......... : SELV CIRCUITS are only
connected to other SELV
CIRCUITS and/or LIMITED
CURRENT CIRCUITS.
Pass
2.3
TNV circuits
N/A
2.3.1
Limits
2.3.2
2.3.3
Result - Remark
Pass
SELV levels are maintained
after single fault condition.
SELV CIRCUITS are
separated from other circuits
by providing DOUBLE or
REINFORCED INSULATION
in the meaning of this
standard.
No TNV presents.
N/A
-
Separation from other circuits and from accessible
parts
N/A
Insulation employed............................................... :
-
Separation from hazardous voltages
Connection of TNV circuits to other circuits
Insulation employed............................................... :
2.3.5
Pass
Type of TNV circuits .............................................. :
Insulation employed............................................... :
2.3.4
Verdict
Test for operating voltages generated externally
Underwriters Laboratories Inc.
N/A
N/A
N/A
Issue Date:
2008-10-28
Page 12 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.4
Limited current circuits
2.4.1
General requirements
The current measured
between the user accessible
part of a limited current circuit
by IEC leakage current meter.
Conducted on bridging
capacitor CY1.
Pass
2.4.2
Limit values
0.7 mA peak.
Pass
Pass
Frequency (Hz) ...................................................... : 60 Hz
-
Measured current (mA).......................................... : 0.165 MIU maximum.
-
Measured voltage (V) ............................................ : 354 V peak maximum.
-
Measured capacitance (mF) .................................. : CY1: 2200 pF.
-
2.4.3
Connection of limited current circuits to other
circuits
The LIMITED CURRENT
CIRCUIT connected to other
circuits complies with the
requirements of Sub-clause
2.4.1.
N/A
2.5
Limited power sources
N/A
Inherently limited output
N/A
Impedance limited output
N/A
Overcurrent protective device limited output
N/A
Regulating network limited output under normal
operating and single fault condition
N/A
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
power (VA):............................................................ :
-
Current rating of overcurrent protective device (A) :
-
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 13 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.6
Provisions for earthing and bonding
Pass
2.6.1
Protective earthing
N/A
2.6.2
Functional earthing
2.6.3
Protective earthing and protective bonding
conductors
Pass
2.6.3.1
General
Pass
2.6.3.2
Size of protective earthing conductors
Functional earthing separated
from Hazardous voltage by
reinforced insulation.
Functional Earthing connected
to protective bonding.
Insulation on functional
earthing conductor is not
green-yellow.
Power supply cord earthing
conductor complies with Table
3B (Optional provided).
Rated current (A), cross-sectional area (mm2),
(See appended table 1.5.1)
AWG ...................................................................... :
2.6.3.3
Size of protective bonding conductors
Only functional Earthing
provided.
Verdict
Pass
Pass
N/A
Rated current (A), cross-sectional area (mm2),
AWG ...................................................................... :
-
2.6.3.4
Resistance (Ohm) of earthing conductors and their
terminations, test current (A) ................................. :
N/A
2.6.3.5
Colour of insulation ................................................ :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
-
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 14 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
Pass
2.7.1
Basic requirements
Protection provided as part of
the building installation.
Pass
Instructions when protection relies on building
installation
Pluggable Type A.
Pass
2.7.2
Faults not covered in 5.3
Protection from faults not
covered in 5.3 are provided by
installation.
Pass
2.7.3
Short-circuit backup protection
The building installation is
considered as providing shortcircuit backup protection for
PLUGGABLE EQUIPMENT
TYPE A.
Pass
2.7.4
Number and location of protective devices............ : One protective device in the
"LIVE" phase
Pass
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................ : No protective device is
provided in the neutral
conductor.
N/A
Underwriters Laboratories Inc.
Verdict
Issue Date:
2008-10-28
Page 15 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
2.8
Safety interlocks
2.8.1
General principles
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ................................................ :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
Pass
2.9.1
Properties of insulating materials
Natural rubber, materials
containing asbestos and
hygroscopic materials are not
used as insulation.
Pass
2.9.2
Humidity conditioning
The humidity treatment was
conducted for 48 hrs.
Electric strength test was
conducted after the humidity
treatment.
Pass
2.9.3
Result - Remark
Verdict
N/A
No SAFETY INTERLOCKS
used.
N/A
Humidity (%) .......................................................... : 95
-
Temperature (°C)................................................... : 30
-
Grade of insulation
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 16 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.10
Clearances, creepage distances and distances through insulation
Pass
2.10.1
General
Pass
Pollution degree 2 applicable.
Verdict
FUNCTIONAL INSULATION
complied with Sub-clause
5.3.4.
2.10.2
Determination of working voltage
Pass
2.10.3
Clearances
2.10.3.1
General
2.10.3.2
Clearances in primary circuit
(see appended table 2.10.3
and 2.10.4).
Pass
2.10.3.3
Clearances in secondary circuits
Functional insulation only.
Waived by short circuit fault
test per Sub-clause 5.3.4.
Pass
2.10.3.4
Measurement of transient voltage levels
2.10.4
Creepage distances
(see appended table 2.10.3
and 2.10.4).
Pass
Pass
N/A
(see appended table 2.10.3
and 2.10.4).
CTI tests................................................................. : Material Group IIIb assumed
unless otherwise indicated.
100 <= CTI < 175
Pass
-
2.10.5
Solid insulation
Solid or laminated insulating
materials having adequate
thickness are provided.
Pass
2.10.5.1
Minimum distance through insulation
See Table 2.10.5
Pass
2.10.5.2
Thin sheet material
Two layers used, each of
which complies with the
required electric strength test
(see appended table 5.2)
Pass
2.10.5.3
2.10.5.4
Number of layers (pcs) .......................................... : Reinforced Insulation - 2
layers
-
Electric strength test .............................................. : (see appended table 5.2)
-
Printed boards
N/A
Distance through insulation
N/A
Electric strength test for thin sheet insulating
material .................................................................. :
-
Number of layers (pcs) .......................................... :
N/A
Wound components
The employed UL Recognized
wiring meets the requirements
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Page 17 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
of 2.10.5.4 and Annex U.
Number of layers (pcs) .......................................... : Three extruded layers.
Pass
Two wires in contact inside wound component;
Physical separation in the form
angle between 45° and 90° ................................... : of insulating sleeving provided
to relieve mechanical stress at
the crossover point.
Pass
2.10.6
Coated printed boards
N/A
2.10.6.1
General
N/A
2.10.6.2
Sample preparation and preliminary inspection
N/A
2.10.6.3
Thermal cycling
N/A
2.10.6.4
Thermal ageing (°C) .............................................. :
N/A
2.10.6.5
Electric strength test .............................................. :
-
2.10.6.6
Abrasion resistance test
2.10.7
2.10.8
N/A
Electric strength test .............................................. :
-
Enclosed and sealed parts .................................... :
N/A
Temperature T1=T2 = Tma - Tamb +10K (°C)...... :
N/A
Spacings filled by insulating compound................. : Approved Optical Isolator
used.
Pass
Electric strength test .............................................. : (see appended table 2.10.5)
-
2.10.9
Component external terminations
N/A
2.10.10
Insulation with varying dimensions
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 18 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
3
WIRING, CONNECTIONS AND SUPPLY
Pass
3.1
General
Pass
3.1.1
Current rating and overcurrent protection
All internal wires and
INTERCONNECTING
CABLES possess adequate
cross-sectional areas for their
intended application and all
internal wirings are adequately
insulated.
Pass
3.1.2
Protection against mechanical damage
The wires are routed away
from sharp edges and parts
which could damage
insulation.
Pass
3.1.3
Securing of internal wiring
Internal wiring routed,
supported, clamped or secured
in a manner that excessive
strain on wire and on terminal
connections, loosening of
terminal connections and
damage of conductor
insulation are unlikely.
Pass
3.1.4
Insulation of conductors
The insulation of the individual
conductors is suitable for the
application and the working
voltage.
Pass
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
N/A
3.1.9
Termination of conductors
Pass
10 N pull test
Pass
3.1.10
Sleeving on wiring
Result - Remark
The sleeving used as
supplementary insulation on
internal wiring is retained by
positive means.
Underwriters Laboratories Inc.
Verdict
Pass
Issue Date:
2008-10-28
Page 19 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
3.2
Connection to an a.c. mains supply or a d.c. mains supply
Pass
3.2.1
Means of connection
Pass
3.2.1.1
Connection to an a.c. mains supply
Pass
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
The unit is provided with an
appliance inlet.
Number of conductors, diameter (mm) of cable and
conduits.................................................................. :
Verdict
-
3.2.4
Appliance inlets
The appliance inlet complies
with IEC 60320.
Appliance inlet can be inserted
without difficulty and so placed
that, after insertion of the
connector, the equipment is
not supported by the connector
for any position of normal use
on a flat surface.
Pass
3.2.5
Power supply cords
Power supply cord suitable for
application and subject to
country's national code and
regulations to be provided by
the manufacturer.
(Optional provided).
Pass
3.2.5.1
AC power supply cords
(Optional provided).
Pass
Type ....................................................................... : (See appended table 1.5.1)
-
Rated current (A), cross-sectional area (mm²),
(See appended table 1.5.1)
AWG ...................................................................... :
-
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
Strain Relief provided for
output cord.
Pass
Mass of equipment (kg), pull (N) ........................... : Equipment 0.49 kg maximum.
30 N pulling force was applied.
-
Longitudinal displacement (mm)............................ : 0.6 mm maximum.
-
3.2.7
Protection against mechanical damage
3.2.8
Cord guards
Cord not exposed to sharp
points or edges.
Pass
N/A
D (mm); test mass (g) ............................................ :
Underwriters Laboratories Inc.
-
Issue Date:
2008-10-28
Page 20 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Radius of curvature of cord (mm) .......................... :
Verdict
-
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
The equipment is not
permanently connected or
provided with a nondetachable power supply cord.
Rated current (A), cord/cable type, cross-sectional
area (mm²) ............................................................. :
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
-
3.3.6
Wiring terminals design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 21 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
3.4
Disconnection from the mains supply
Pass
3.4.1
General requirement
Pass
3.4.2
Disconnect devices
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
No isolating switches fitted in
flexible cords.
N/A
3.4.6
Single-phase equipment and d.c. equipment
Disconnect device disconnects
all poles simultaneously.
Pass
3.4.7
Three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
Pass
3.5.1
General requirements
3.5.2
Types of interconnection circuits ........................... : Interconnection circuits are
SELV CIRCUITS/LIMITED
CURRENT CIRCUITS.
Pass
3.5.3
ELV circuits as interconnection circuits
N/A
4
PHYSICAL REQUIREMENTS
Pass
4.1
Stability
N/A
The Appliance Inlet is used as
the disconnect device.
Interconnection circuit did
continued conformance to the
requirements of SELV
CIRCUITS.
Angle of 10°
Based on construction review,
the test was deemed not
necessary.
Test: force (N)........................................................ :
Underwriters Laboratories Inc.
Verdict
Pass
Pass
N/A
N/A
Issue Date:
2008-10-28
Page 22 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
4.2
Mechanical strength
Pass
4.2.1
General
Pass
4.2.2
Steady force test, 10 N
Pass
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
4.2.5
Impact test
No hazards as a result of the
250 N test.
Verdict
Pass
Pass
Fall test
500 g steel sphere ball fall
from 1.3 m height onto the
enclosure, there are no safety
relevant damages.
Pass
Swing test
N/A
4.2.6
Drop test
N/A
4.2.7
Stress relief test
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
N/A
No indication of shrinkage or
distortion on enclosures due to
the stress relief test ( 101.3
degree C/7 h).
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Page 23 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.3
Design and construction
4.3.1
Edges and corners
4.3.2
Handles and manual controls; force (N) ................ :
N/A
4.3.3
Adjustable controls
N/A
4.3.4
Securing of parts
No loosening of parts impairing
creepage distances or
clearances over
supplementary or reinforced
insulation is likely to occur.
Pass
4.3.5
Connection of plugs and sockets
The equipment does not have
any interchangeable
plugs/sockets.
Pass
4.3.6
Direct plug-in equipment
N/A
Dimensions (mm) of mains plug for direct plug-in . :
N/A
Torque and pull test of mains plug for direct plug-in;
torque (Nm); pull (N) .............................................. :
N/A
4.3.7
Heating elements in earthed equipment
N/A
4.3.8
Batteries
N/A
4.3.9
Oil and grease
N/A
4.3.10
Dust, powders, liquids and gases
N/A
4.3.11
Containers for liquids or gases
N/A
4.3.12
Flammable liquids.................................................. :
N/A
Quantity of liquid (l)................................................ :
N/A
Flash point (°C)...................................................... :
N/A
4.3.13
Radiation; type of radiation
Pass
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
Pass
All edges and corners judged
to be sufficiently well rounded
so as not to constitute a
hazard.
Pass
Measured radiation (pA/kg) ................................... :
-
Measured high-voltage (kV)................................... :
-
Measured focus voltage (kV) ................................. :
-
CRT markings........................................................ :
-
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 24 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification .......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation........ :
N/A
4.3.13.5
Laser (including LEDs)
This product contains only
visible indicator LEDs (Class
1). No IEC60825-1 evaluation
was deemed necessary.
Additional review may be
required at the discretion of the
accepting NCB.
Laser class............................................................. : (For indicator LEDs, see above
statement.)
Verdict
Pass
-
4.3.13.6
Other types ............................................................ :
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
Pass
4.5.1
Maximum temperatures
4.5.2
No hazardous moving part
presents.
The equipment and its
components did not attain
excessive temperatures during
normal operation.
(see appended table 4.5)
N/A
Pass
Normal load condition per Annex L ....................... : Operated in the most
unfavorable way of operation
given in the operating
instructions until steady
conditions established.
Pass
Resistance to abnormal heat
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 25 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
4.6
Openings in enclosures
Pass
4.6.1
Top and side openings
Pass
Dimensions (mm)................................................... : No openings.
4.6.2
Bottoms of fire enclosures
Doors or covers in fire enclosures
4.6.4
Openings in transportable equipment
4.6.5
Adhesives for constructional purposes
Pass
Construction of the bottom..................................... : No openings.
4.6.3
Verdict
N/A
No openings.
Conditioning temperature (°C)/time (weeks) ......... :
Underwriters Laboratories Inc.
Pass
N/A
-
Issue Date:
2008-10-28
Page 26 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Pass
Method 1, selection and application of components Method 1: Selection and
wiring and materials
application of components and
materials which minimize the
possibility of ignition and
spread of flame.
Pass
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Pass
4.7.2.1
Parts requiring a fire enclosure
A fire enclosure covers all
parts except as noted in
4.7.2.2.
Pass
4.7.2.2
Parts not requiring a fire enclosure
Plugs and connectors forming
part of a power supply cord or
interconnecting cable.
Pass
4.7.3
Materials
4.7.3.1
General
The propagation of fire is
minimized through satisfying
the requirement of
constructions and materials.
Pass
4.7.3.2
Materials for fire enclosures
Equipment is moveable with
mass less than 18 kg. Fire
enclosure material is V-1
minimum
Pass
4.7.3.3
Materials for components and other parts outside
fire enclosures
Pass
4.7.3.4
Materials for components and other parts inside fire PWBs are rated min. V-1.
enclosures
All internal materials are rated
V-2 or better or are mounted
on a PWB rated V-1 or better
Internal wiring is UL
Recognized, marked VW-1 or
FT-1 and strapped by
individual cable ties (where
needed).
See Table 1.5.1 for material
information.
Pass
4.7.3.5
Materials for air filter assemblies
N/A
4.7.3.6
Materials used in high-voltage components
N/A
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 27 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
Pass
5.1.1
General
Pass
5.1.2
Equipment under test (EUT)
Equipment designed for
connection to only one power
source.
Pass
5.1.3
Test circuit
Figure 5A.
Single phase equipment
intended only for connection to
TN system.
Pass
5.1.4
Application of measuring instrument
Using the measuring
instrument specified in annex
D.1.
Test made to 10 x 20 cm metal
foil in contact with accessible
non-conductive part.
Pass
5.1.5
Test procedure
Pass
5.1.6
Test measurements
Pass
Test voltage (V) ..................................................... : 264V/60Hz
-
Measured touch current (mA) ................................ : Max. 0.165 mA measured at
output (-) as "e" open.
Max. 0.004 mA measured at
Enclosure with foil as "e"
closed.
-
Max. allowed touch current (mA)........................... : 0.25 mA for Accessible plastic
enclosure.
3.5 mA for output (-) and
output (+).
-
Measured protective conductor current (mA) ........ : --
-
Max. allowed protective conductor current (mA) ... : --
-
5.1.7
Equipment with touch current exceeding 3.5 mA .. :
N/A
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and from
telecommunication networks
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable distribution
system
N/A
Test voltage (V) ..................................................... :
-
Measured touch current (mA) ................................ :
-
No TNV presents.
Underwriters Laboratories Inc.
N/A
Issue Date:
2008-10-28
Page 28 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Max. allowed touch current (mA)........................... :
-
5.1.8.2
Summation of touch currents from
telecommunication networks ................................. :
N/A
5.2
Electric strength
Pass
5.2.1
General
Based on the electric strength
test the use of the insulating
materials within the equipment
is satisfactory.
Pass
5.2.2
Test procedure
No insulation breakdown
detected during the test.
(See Table 5.2 for details)
Pass
5.3
Abnormal operating and fault conditions
5.3.1
Protection against overload and abnormal
operation
5.3.2
Motors
5.3.3
Transformers
Transformers are constructed
in accordance with the
applicable Clause and Annex
C.
(see appended Annex C)
Pass
5.3.4
Functional insulation .............................................. : Functional insulation complies
with the requirements (c).
Pass
5.3.5
Electromechanical components
N/A
5.3.6
Simulation of faults
5.3.7
Unattended equipment
5.3.8
Compliance criteria for abnormal operating and
fault conditions
Pass
(see appended table 5.3)
Pass
N/A
(see appended table 5.3)
Pass
N/A
No fire, emission of molten
metal, deformation, excessive
temperature rises or insulation
breakdown was detected
during these tests.
Underwriters Laboratories Inc.
Pass
Issue Date:
2008-10-28
Page 29 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Test voltage (V) ..................................................... :
-
Current in the test circuit (mA) ............................... :
-
6.1.2.2
Exclusions.............................................................. :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) .......................................... :
-
Current limiting method.......................................... :
-
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 30 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
Protection of cable distribution system service persons, and users of other
equipment connected to the system, from hazardous voltages in the equipment
N/A
7.2
Protection of equipment users from overvoltages
on the cable distribution system
N/A
7.3
Insulation between primary circuits and cable
distribution systems
N/A
7.3.1
General
N/A
7.3.2
Voltage surge test
N/A
7.3.3
Impulse test
N/A
A
Annex A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples ................................................................. :
-
Wall thickness (mm) .............................................. :
-
A.1.2
Conditioning of samples; temperature (°C) ........... :
N/A
A.1.3
Mounting of samples.............................................. :
N/A
A.1.4
Test flame
N/A
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s)...................................... :
-
Sample 2 burning time (s)...................................... :
-
Sample 3 burning time (s)...................................... :
-
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 31 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
A.2
Flammability test for fire enclosures of movable equipment having a total
mass not exceeding 18 kg, and for material and components located inside
fire enclosures (see 4.7.3.2 and 4.7.3.4)
A.2.1
Samples, material .................................................. :
-
Wall thickness (mm) .............................................. :
-
N/A
A.2.2
Conditioning of samples
N/A
A.2.3
Mounting of samples
N/A
A.2.4
Test flame
N/A
A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
A.2.7
Sample 1 burning time (s)...................................... :
-
Sample 2 burning time (s)...................................... :
-
Sample 3 burning time (s)...................................... :
-
Alternative test acc. to IEC 60695-2-2, cl. 4, 8
N/A
Sample 1 burning time (s)...................................... :
-
Sample 2 burning time (s)...................................... :
-
Sample 3 burning time (s)...................................... :
-
A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
A.3.3
Compliance criterion
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 32 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
B
Annex B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and
5.3.2)
N/A
B.1
General requirements
N/A
Position .................................................................. :
-
Manufacturer.......................................................... :
-
Type ....................................................................... :
-
Rated values.......................................................... :
-
B.2
Test conditions
N/A
B.3
Maximum temperatures
N/A
B.4
Running overload test
N/A
B.5
Locked-rotor overload test
N/A
Test duration (days)............................................... :
-
Electric strength test: test voltage (V).................... :
-
B.6
Running overload test for d.c. motors in secondary
circuits
N/A
B.7
Locked-rotor overload test for d.c. motors in secondary circuits
N/A
B.7.1
Test procedure
N/A
B.7.2
Alternative test procedure; test time (h)................. :
N/A
B.7.3
Electric strength test
N/A
B.8
Test for motors with capacitors
N/A
B.9
Test for three-phase motors
N/A
B.10
Test for series motors
N/A
Operating voltage (V)............................................. :
Underwriters Laboratories Inc.
-
Issue Date:
2008-10-28
Page 33 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
C
Annex C, TRANSFORMERS (see 1.5.4 and 5.3.3)
Verdict
Pass
Position .................................................................. : T1.
-
Manufacturer.......................................................... : (See Table 1.5.1)
-
Type ....................................................................... : (See Table 1.5.1)
-
Rated values.......................................................... : (See Table 1.5.1)
-
Method of protection .............................................. : Regulation network provided.
-
C.1
Overload test
(see appended table 5.3)
Pass
C.2
Insulation
(see appended table 5.2)
Pass
Protection from displacement of windings ............. : Triple insulated wire used.
Pass
D
Annex D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
Pass
D.1
Measuring instrument
Pass
D.2
Alternative measuring instrument
N/A
E
Annex E, TEMPERATURE RISE OF A WINDING
N/A
F
Annex F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10)
Pass
Using the measuring
instrument specified in annex
D.1.
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 34 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
G
Annex G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
G.1
Summary of the procedure for determining
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)
N/A
G.2.1
AC mains supply
N/A
G.2.2
DC mains supply
N/A
G.3
Determination of telecommunication network
transient voltage (V) :............................................. :
N/A
G.4
Determination of required withstand voltage (V) ... :
N/A
G.5
Measurement of transient levels (V)...................... :
N/A
G.6
Determination of minimum clearances .................. :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
Annex J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
Metal used ............................................................. :
Verdict
-
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V) .......... :
N/A
K.3
Thermostat endurance test; operating voltage (V) :
N/A
K.4
Temperature limiter endurance; operating voltage
(V) .......................................................................... :
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 35 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
L
Annex L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
Pass
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
L.7
Other business equipment
Pass
M
Annex M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz) ...................................................... :
-
M.3.1.2
Voltage (V)............................................................. :
-
M.3.1.3
Cadence; time (s), voltage (V)............................... :
-
M.3.1.4
Single fault current (mA) ........................................ :
-
M.3.2
Tripping device and monitoring voltage................. :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V)............................................ :
N/A
N
Annex N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and
clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
Underwriters Laboratories Inc.
Verdict
Issue Date:
2008-10-28
Page 36 of 54
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
P
Annex P, NORMATIVE REFERENCES
Pass
Q
Annex Q, BIBLIOGRAPHY
Pass
R
Annex R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
Annex S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
Annex T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see
1.1.2)
N/A
............................................................................... :
U
Annex U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
............................................................................... : Used of three layers of
extruded insulation wire were
approved. (See append table
1.5.1)
Underwriters Laboratories Inc.
Verdict
-
Pass
-
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 1 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.5.1
TABLE: list of critical components
Object/part No.
Manufacturer/
trademark
type/model
technical data
Product Category
CCN(s)
Label
Various
Various
PGDQ2 or PGJI2
Enclosure
--
--
--
--
- Enclosure material
SABIC INNOVATIVE SE1X
Plastics China Ltd.
Various
Various
70 degree C, if maximum
surface temperature not
specified.
Measured minimum thick 2.75
mm.
Two halves construction,
secured together by ultrasonic
welding. See enclosure 4-01
and 4-02 for dimension details.
V-1, 105 degree C, minimum
1.5 mm thick.
Detachable, limited to between
1.5 and 4.5 m long, 18 AWG,
type SVT or SPT-2, minimum
125 Vac, 10 A, with NEMA 515P or 250 Vac, 10 A, with
NEMA 6-15P. The Other end in
an appliance coupler (with
cord-connected body,
grounding type, suitable for
cord size, rating not less than
that of attachment plug)
External used wire, Jacketed.
FEP, PTFE, PVC, TFE,
Neoprene, Polyimide or marked
VW-1; FT-1, max. 3.05 m
length, 80 degree C, min. 300
V. Mechanically secured and
soldered to PWB.
Required
Marks of
Conformity
UL
QMFZ2
UL
ZJCZ and RTRT
and AXUT, or
ELBZ
UL
ZJCZ,
AVLV2
UL
Power supply cord
(optional)
Output cord
Various
2464
Underwriters Laboratories Inc.
Pass
Supplement ID
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 2 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Strain Relief for Output
cord
Various
Various
PWB
Various
Various
Appliance Inlet (For GT41069P9012-T3AZ, GT41069PWWVV-X.XT3AZ)
Appliance Inlet (For GT41069P9012-T3 Z, GT41069PWWVV-X.X-T3
Z) (Alternate)
Fuse (FS1)
SUN FAIR
S-02
ELECTRIC WIRE &
CABLE (HK) CO LTD
Verdict
Min V-1, plastic bushing
integrally molded on output
cord, see enclosure 4-03 for
details
Rated V-1 minimum, 130
degree C minimum
2.5A, 250V, 70 degree C
minimum
QMFZ2
UL
4-03
ZPMV2
UL
5-01
AXUT2
UL
TECX-UNIONS
TECHNOLOGY
CORP
TU-301 Series
15A, 250V, 105 degree C
minimum
AXUT2
UL
WALTER
ELECTRONIC CO
LTD
DAS & SONS
INTERNATIONAL
LTD
Conquer Electronics
Co Ltd
SAVE FUSETECH
INC
Various
Various
ICP
T 3.15A, 250Vac
JDYX2
UL
385T1315
T 3.15A, 250Vac
JDYX2
UL
MST
T 3.15A, 250Vac
JDYX2
UL
SS-5
T 3.15A, 250Vac
JDYX2
UL
Various
Various
JDYX
XUHT2
UL
UL
Various
NF00081
--
--
- Core
--
--
--
--
- Coil
Various
Various
Listed, T 3.15A, 250Vac
Rated minimum 300 Vac,
minimum 385 Vdc.
Varnished, see enclosure 4-04
for details, 130 degree C
minimum.
Ferrite, measured OD 12 mm
by 5 mm ID by 3.5 mm width
Rated minimum 130 degree C.
OBMW2
UL
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Varistor (MOV1)
(Optional)
Line Choke (LF1)
(Optional)
Underwriters Laboratories Inc.
4-04
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 3 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
- Triple Insulated
Winding Wire
- Tape
- Varnish
X capcitor (CX1)
(optional)
Furukawa Electric
Co., Ltd.
Various
Various
Ultra Tech Xiphi
Enterprise Co., Ltd
X capcitor (CX1)
(optional) (Alternate)
TENTA ELECTRIC
INDUSTRIAL CO
LTD
CHENG TUNG
INDUSTRIAL CO
LTD
Various
MEX
--
--
X capcitor (CX1)
(optional) (Alternate)
Line Choke (LF2)
(Optional)
- Core
TEX-E
Rated 130 degree C.
OBJT2
UL
Various
Various
HQX
Rated 130 degree C.
Rated minimum 130 degree C.
Max. 0.47 uF, min. 250 Vac,
100 degree C, Class X1 or X2
type
Max. 0.47 uF, min. 250 Vac,
100 degree C, Class X1 or X2
type
Max. 0.47 uF, min. 250 Vac,
100 degree C, Class X1 or X2
type
See enclosure 4-05 for details,
130 degree C minimum.
Ferrite, measured OD 21.5mm
by 6 mm ID by 11 mm width
Rated minimum 130 degree C.
Each rated 1M ohm, 1/4W
SMD type, connected in series
Rated 4A, 600 V minimum
Rated 400 V, maximum 120uF,
minimum 105 degree C,
provided with integral pressure
relief
Varnished, see enclosure 4-06
for details, 130 degree C
minimum.
V-0, 150degree C, Phenolic,
thickness 0.8mm minimum
V-0, 150degree C, Phenolic,
thickness 0.71mm minimum
Ferrite, overall 32.0 by 19.5 by
OANZ2
OBOR2
FOWX2
UL
UL
UL
FOWX2
UL
FOWX2
UL
--
--
--
--
OBMW2
--
UL
--
---
---
--
--
QMFZ2
UL
QMFZ2
UL
--
--
CTX
NF00083
- Coil
Bleeder resistor (RS1,
RS2)
Bridge Diode (BD1)
Storage Capacitor (C4)
Various
--
Various
--
---
---
PFC Choke (L1)
Various
RC00136
- Bobbin
Chang Chun Plastics T375J
Co., Ltd.
SUMITOMO
PM-9820
BAKELITE CO LTD
---
- Bobbin (Alternate)
- Core
Verdict
Underwriters Laboratories Inc.
4-05
4-06
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 4 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
- Coil
- Tape
- Varnish
Line Choke (L2)
Various
Various
Various
Various
Various
Various
Various
RC00134
- Core
--
--
- Coil
Tubing/Sleeving
Various
Great Holding
Industrial Co. Ltd.
Heat Sink (HS1)
(Primary) (For GT41069P9012-T3 Z, GT41069PWWVV-X.X-T3
Z)
Heat Sink (HS1)
(Primary) (For GT41069P9012-T3AYZ,
GT-41069PWWVV-X.XT3AZ) (Alternate)
Heat Sink (HS2)
(Secondary)
Heat Sink (Cover)
(Primary)
Heat Sink (Chassis)
(Primary)
Tubing (For HS1)
--
Various
TFL,
TFS,
TFT
--
--
Verdict
30.0 mm..
Rated minimum 130 degree C.
Rated 130 degree C.
Rated minimum 130 degree C.
See enclosure 4-07 for details,
130 degree C minimum.
Ferrite, measured OD 21.5mm
by 6 mm ID by 9 mm width
Rated minimum 130 degree C.
Rated 200 degree C
OBMW2
OANZ2
OBOR2
--
UL
UL
UL
--
--
--
OBMW2
YDPU2
UL
UL
Aluminum material, see
enclosure 4-08 for details
--
--
4-08
--
Aluminum material, see
enclosure 4-09 for details
--
--
4-09
--
--
--
4-10
--
--
--
4-11
--
--
--
4-12
CHANGYUAN
ELECTRONICS
(SHENZHEN) CO
LTD
CB-HFT
Aluminum material, see
-enclosure 4-10 for details
Aluminum material, see
-enclosure 4-11 for details
Aluminum material, see
-enclosure 4-12 for details
FEP, PTFE, PVC, TFE,
YDPU2
neoprene, polyimide or marked
VW-1; rated minimum 125
degree C, minimum 300 V, see
enclosure 4-08 and 4-09 for
Underwriters Laboratories Inc.
UL
4-07
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 5 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Tubing (For HS2)
CHANGYUAN
ELECTRONICS
(SHENZHEN) CO
LTD
CB-HFT
Transformer (T1) (For
GT-41069P9012-T3YZ)
Transformer (T1) (For
GT-41069PWWVV-X.XT3YZ) (Alternate)
- Insulation system for
Transformer (T1)
- Core
Globtek
XF00500
details, thickness 0.4 mm
minimum.
FEP, PTFE, PVC, TFE,
YDPU2
neoprene, polyimide or marked
VW-1; rated minimum 125
degree C, minimum 300 V, see
enclosure 4-10 for details,
thickness 0.4 mm minimum.
See enclosure 4-15 for details --
Globtek
XF00501
See enclosure 4-16 for details
--
--
ENG Electric Co.,
Ltd.
--
ENG130-1
Class B, 130 degree C
OBJY2
UL
--
--
--
- Bobbin
Chang Chun Plastics
Co., Ltd.
SUMITOMO
BAKELITE CO LTD
Great Holding
Industrial Co. Ltd.
QMFZ2
UL
QMFZ2
UL
YDPU2
UL
John C. Dolph Co.
P D George/Viking
3M Company
3M Company
TFL,
TFS,
TFT
BC-346A
V1630FS
1350T-1
1350F(#)
EE type, Ferrite, overall each
28.5mm by 28.5 mm by 8 mm
V-0, 150degree C, Phenolic,
thickness 0.8mm minimum
V-0, 150degree C, Phenolic,
thickness 0.71mm minimum
Rated 200 degree C
Rated minimum 200 degree C.
Rated minimum 130 degree C.
130 degree C.
130 degree C.
OBOR2
OBOR2
OANZ2
OANZ2
UL
UL
UL
UL
3M Company
44
130 degree C.
OANZ2
UL
Bondtec Pacific Co.,
Ltd.
370S
130 degree C.
OANZ2
UL
- Bobbin (Alternate)
- Tubing/Sleeving
- Varnish
- Varnish (Alternate)
- Insulation Tape
- Insulation Tape
(Alternate)
- Insulation Tape
(Alternate)
- Insulation Tape
(Alternate)
T375J
PM-9820
Underwriters Laboratories Inc.
UL
--
4-15
4-16
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 6 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
- Triple Insulated
Winding Wire
Semiconductor (US1,
US2, US3)
Bridging -Capacitor
(CY1)
Great Leoflon
Industrial Co., Ltd.
--
TRW(B)
Rated 130 degree C.
OBJT2
UL
--
Rated 0.7A, minimum 650 V.
--
--
TDK Corp
CD
FOWX2
UL
Bridging -Capacitor
(CY1) (Alternate)
Success Electronics
Co Ltd
SE
FOWX2
UL
Bridging -Capacitor
(CY1) (Alternate)
WALSIN
TECHNOLOGY
CORP / Pan
Overseas
-Sharp Corp.,
Electronic
Components Group
Bright LED
Electronics Corp.
Lite-On Technology
Corp.
Various
AH
Rated maximum 2200 pF,
minimum 250 Vac, 125 degree
C, Class Y1
Rated maximum 2200 pF,
minimum 250 Vac, 125 degree
C, Class Y1
Rated maximum 2200 pF,
minimum 250 Vac, 125 degree
C, Class Y1
FOWX2
UL
-PC817
Rated 10A, minimum 600 V.
Minimum 3000 Vac isolation.
Double protection.
-FPQU2
-UL
BPC-817xxxxxx
Minimum 3000 Vac isolation.
Double protection.
Minimum 3000 Vac isolation.
Double protection.
Rated V-2 minimum.
FPQU2
UL
FPQU2
UL
QMFZ2
UL
UL
--
Transistor (Q1, Q2)
Optical Isolator (U1)
Optical Isolator (U1)
(Alternate)
Optical Isolator (U1)
(Alternate)
Internal Plastic Part
Materials
Internal Wiring (Primary) Various
Current sense resistor
(R1)
Current sense resistor
(R2)
Glue
LTV-817
Various
Various
--
--
FEP, PTFE, PVC, TFE,
AVLV2
neoprene, Polyimide or marked
VW-1; min. 300 V, min. 80
degree C.
0.27 ohm, 2W.
--
--
--
0.24 ohm, 2W.
--
--
Various
Various
V-2 min. Components (LF1,
LF2, L1, L2, C4, R1, R2,
QMFZ2
UL
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 7 of 7
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1350T-1
Output cord) need
FEP, PTFE, PVC, TFE,
YDPU2
neoprene, polyimide or marked
VW-1; rated minimum 125
degree C, minimum 300 V,
thickness 0.4 mm minimum.
130 degree C.
OANZ2
UL
Bondtec Pacific Co.,
Ltd.
370S
130 degree C.
OANZ2
UL
Various
Various
V-2 min, see Enclosure 4-13 for QMFZ2
details
UL
4-13
FORMEX,DIV OF IL
TOOL WORKS
INC,FRMRLY
FASTEX,DIV OF IL
TOOL WORKS INC
FORMEX GK
V-2 min, thickness 0.4 mm
minimum, see Enclosure 4-14
for details
UL
4-14
- Tubing for Functional
Earthing
GUANGZHOU
KAIHENG
ENTERPRISE
GROUP
K-2
Insulation Tape
(between C10 and Heat
Sink (Cover))
Insulation Tape
(between C10 and Heat
Sink (Cover)) (Alternate)
Insulation sheet
(between PWB and
Appliance Inlet) (For GT41069P9012-T3 Z, GT41069PWWVV-X.X-T3
Z)
Insulation sheet for Heat
Sink (Chassis)
3M Company
Underwriters Laboratories Inc.
QMFZ2
UL
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 1 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
1.6.2
TABLE: electrical data (in normal conditions)
I rated (A)
U (V)
---
--
--
FS1
--
104.44
1163
I fuse (mA) condition/status
-Model:
GT-41069P9012-T3YZ.
1163
Maximum normal load
FS1
--
104.37
1162
1162
Maximum normal load
FS1
1.5
103.56
1037
1037
Maximum normal load
FS1
1.5
103.52
1037
1037
Maximum normal load
FS1
1.5
101.53
432
432
Maximum normal load
FS1
1.5
101.46
436
436
Maximum normal load
FS1
--
101.44
411
411
Maximum normal load
FS1
--
101.42
415
415
Maximum normal load
FS1
--
101.37
397
397
Maximum normal load
FS1
--
101.34
402
402
Maximum normal load
--
--
--
--
--
FS1
--
101.97
1134
1134
Model:
GT-41069P9019-T3YZ.
Maximum normal load
FS1
--
101.92
1134
1134
Maximum normal load
FS1
1.5
101.20
1013
1013
Maximum normal load
FS1
1.5
101.16
1013
1013
Maximum normal load
FS1
1.5
99.57
425
425
Maximum normal load
FS1
1.5
99.50
428
428
Maximum normal load
FS1
--
99.45
403
403
Maximum normal load
FS1
--
99.45
408
408
Maximum normal load
FS1
--
99.40
390
390
Maximum normal load
FS1
--
99.36
395
395
Maximum normal load
90Vac/50H
z
90Vac/60H
z
100Vac/50
Hz
100Vac/60
Hz
240Vac/50
Hz
240Vac/60
Hz
254Vac/50
Hz
254Vac/60
Hz
264Vac/50
Hz
264Vac/60
Hz
I (mA)
Pass
fuse #
--
90Vac/50H
z
90Vac/60H
z
100Vac/50
Hz
100Vac/60
Hz
240Vac/50
Hz
240Vac/60
Hz
254Vac/50
Hz
254Vac/60
Hz
264Vac/50
Hz
264Vac/60
Hz
--
P (W)
Verdict
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 2 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
--
--
--
--
--
--
FS1
--
101.57
1132
1132
FS1
--
101.50
1132
1132
Maximum normal load
FS1
1.5
100.75
1010
1010
Maximum normal load
FS1
1.5
100.72
1010
1010
Maximum normal load
FS1
1.5
99.55
424
424
Maximum normal load
FS1
1.5
99.47
428
428
Maximum normal load
FS1
--
99.43
403
403
Maximum normal load
FS1
--
99.42
407
407
Maximum normal load
FS1
--
99.35
389
389
Maximum normal load
FS1
--
90Vac/50H
z
90Vac/60H
z
100Vac/50
Hz
100Vac/60
Hz
240Vac/50
Hz
240Vac/60
Hz
254Vac/50
Hz
254Vac/60
Hz
264Vac/50
Hz
264Vac/60
Hz
Model:
GT-41069P9024-T3YZ.
Maximum normal load
99.31
394
394
Maximum normal load
supplementary information:
Maximum normal load: Output connected to resistive load as rated and operated continuously.
2.10.3 and
2.10.4
Pass
TABLE: clearance and creepage distance measurements
clearance cl and creepage
distance dcr at/of:
GT-41069P9012-T3YZ.
T1 Pin A TO T1 Pin 1
T1 Pin A TO T1 Pin 2
T1 Pin A TO T1 Pin 4
T1 Pin A TO T1 Pin 5
T1 Pin B TO T1 Pin 1
T1 Pin B TO T1 Pin 2
T1 Pin B TO T1 Pin 4
T1 Pin B TO T1 Pin 5
T1 Pin 9 To T1 Pin 1
T1 Pin 9 To T1 Pin 2
T1 Pin 9 To T1 Pin 4
T1 Pin 9 To T1 Pin 5
U1 Pin 1 TO U1 Pin 3
U1 Pin 1 TO U1 Pin 4
Up
(V)
-512
460
360
364
512
412
336
394
526
168
176
208
348
346
U r.m.s. (V) required cl
(mm)
--349
4.4
315
4.2
167
4
165
4
361
4.4
317
4
163
4
165
4
184
4.4
64
4
67
4
77
4
170
4
169
4
Underwriters Laboratories Inc.
cl (mm)
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
required
dcr (mm)
-7.2
6.8
4
4
7.4
6.8
4
4
4
4
4
4
4
4
dcr
(mm)
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 3 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
U1 Pin 2 TO U1 Pin 3
U1 Pin 2 TO U1 Pin 4
CY1 Pin 1 TO CY1 Pin 2
D4 Pin 1 TO U1 Pin 2
C5 Pin 1 TO RS48 Pin 1
C5 Pin 1 TO RS49 Pin 1
GT-41069P9019-T3YZ.
T1 Pin A TO T1 Pin 1
T1 Pin A TO T1 Pin 2
T1 Pin A TO T1 Pin 4
T1 Pin A TO T1 Pin 5
T1 Pin B TO T1 Pin 1
T1 Pin B TO T1 Pin 2
T1 Pin B TO T1 Pin 4
T1 Pin B TO T1 Pin 5
T1 Pin 9 To T1 Pin 1
T1 Pin 9 To T1 Pin 2
T1 Pin 9 To T1 Pin 4
T1 Pin 9 To T1 Pin 5
U1 Pin 1 TO U1 Pin 3
U1 Pin 1 TO U1 Pin 4
U1 Pin 2 TO U1 Pin 3
U1 Pin 2 TO U1 Pin 4
CY1 Pin 1 TO CY1 Pin 2
D4 Pin 1 TO U1 Pin 2
C5 Pin 1 TO RS48 Pin 1
C5 Pin 1 TO RS49 Pin 1
GT-41069P9024-T3YZ.
T1 Pin A TO T1 Pin 1
T1 Pin A TO T1 Pin 2
T1 Pin A TO T1 Pin 4
T1 Pin A TO T1 Pin 5
T1 Pin B TO T1 Pin 1
T1 Pin B TO T1 Pin 2
T1 Pin B TO T1 Pin 4
T1 Pin B TO T1 Pin 5
T1 Pin 9 To T1 Pin 1
T1 Pin 9 To T1 Pin 2
T1 Pin 9 To T1 Pin 4
T1 Pin 9 To T1 Pin 5
U1 Pin 1 TO U1 Pin 3
U1 Pin 1 TO U1 Pin 4
U1 Pin 2 TO U1 Pin 3
U1 Pin 2 TO U1 Pin 4
CY1 Pin 1 TO CY1 Pin 2
D4 Pin 1 TO U1 Pin 2
C5 Pin 1 TO RS48 Pin 1
346
346
354
418
352
354
-548
486
426
422
556
392
350
406
546
174
186
220
356
352
352
352
350
410
350
348
-560
502
426
416
572
394
356
412
551
176
179
215
376
374
378
374
334
432
334
Result - Remark
170
168
174
183
173
174
-344
302
178
175
364
300
173
175
181
72
83
86
176
174
175
174
172
177
172
172
-355
305
180
175
377
303
174
177
188
58
67
82
191
190
190
189
162
192
162
4
4
4
4
4
4
-4.4
4.2
4.2
4.2
4.4
4
4
4
4.4
4
4
4
4
4
4
4
4
4
4
4
-4.4
4.4
4.2
4
4.6
4
4
4
4.4
4
4
4
4
4
4
4
4
4.2
4
Underwriters Laboratories Inc.
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
Verdict
4
4
4
4
4
4
-7.2
6.6
4
4
7.6
6.4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
-7.4
6.6
4
4
7.8
6.6
4
4
4
4
4
4
4
4
4
4
4
4
4
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
9.13
-8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
8.98
8.98
7.74
7.74
7.88
7.65
7.64
7.86
7.33
7.81
9.13
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 4 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
C5 Pin 1 TO RS49 Pin 1
332
Result - Remark
162
4
9.13
Verdict
4
9.13
supplementary information:
- Functional Insulation employed and complied with the requirements of 5.3.4 (a), (b), or (c).
2.10.5
Pass
TABLE: distance through insulation measurements
distance through insulation di at/of:
Up
(V)
Optical Isolator (U1)
420
test voltage (V)
3000Vac
required di
(mm)
0.4
di
(mm)
>0.4
supplementary information:
--
4.5
TABLE: temperature rise measurements
test voltage (V).......................................... -t1 (°C)........................................................ -t2 (°C)........................................................ --
Pass
--
--
--
--
—
--
--
--
--
—
--
--
--
--
—
maximum temperature T of part/at:
Model:
GT-41069P9012-T3YZ.
Test condition
Duration (hrs)
1.AC Inlet
2.LF1 coil
3.LF2 coil
4.L1 coil
5.L2 coil
6.L3 coil/C10
7.T1 coil
8.T1 core
9.U1 body
10.CY1 body
11.CX1 body
12.C4 body
13.BD1 body
14.PCB under Q2
15. PCB under Q1/D1
T (°C)
--
--
--
--
--
allowed
Tmax (°C)
--
90V,
60Hz
(Label
down)
3
62.0
90.1
109.7
96.1
107.7
93.4
98.9
96.3
95.4
91.9
93.5
98.4
106.4
100.6
107.2
264V,
60Hz
(Label
down)
3.28
54.0
73.7
79.9
78.8
80.8
84.1
84.6
81.9
84.2
78.2
76.3
83.2
80.2
83.5
85.7
90V,
60Hz
(Label
up)
3.38
63.4
93.7
115.0
101.8
111.5
95.8
103.8
101.5
97.1
93.2
99.3
103.1
114.5
103.8
110.8
264V,
60Hz
(Label
up)
3
54.9
75.1
81.9
81.4
82.3
85.4
86.7
83.9
84.5
77.3
78.9
85.2
83.1
84.0
86.7
--
--
-----------------
-70
130
130
130
130
130
110
110
100
125
100
105
130
130
130
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 5 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
16. PCB under Q3
17.MOV1 body
18.Inside Enclosure near T1
19.Outside Enclosure near T1
20.Ambient
Model:
GT-41069P9019-T3YZ.
Test condition
Duration (hrs)
1.AC Inlet
2.LF1 coil
3.LF2 coil
4.L1 coil
5.L2 coil
6.L3 coil/C10
7.T1 coil
8.T1 core
9.U1 body
10.CY1 body
11.CX1 body
12.C4 body
13.BD1 body
14.PCB under Q2
15. PCB under Q1/D1
16. PCB under Q3
17.MOV1 body
18.Inside Enclosure near T1
19.Outside Enclosure near T1
20.Ambient
Model:
GT-41069P9024-T3YZ.
Duration (hrs)
1.AC Inlet
2.LF1 coil
3.LF2 coil
4.L1 coil
5.L2 coil
6.L3 coil/C10
7.T1 coil
8.T1 core
9.U1 body
10.CY1 body
11.CX1 body
12.C4 body
Result - Remark
Verdict
94.4
86.2
81.4
51.6
40.7
--
84.8
72.3
70.8
48.7
40.7
--
97.0
89.9
91.3
70.7
41.0
--
85.7
74.0
76.9
62.6
40.7
--
-------
130
130
95
95
---
90V,
60Hz
(Label
down)
3.6
58.9
86.2
101.5
93.6
96.3
76.9
87.2
86.4
85.8
82.0
89.8
87.1
99.3
90.3
102.0
86.0
83.8
69.9
47.4
40.4
--
264V,
60Hz
(Label
down)
2.56
53.1
72.3
76.4
77.3
76.5
71.2
77.6
77.1
78.5
72.6
74.6
75.3
76.4
78.2
84.3
80.4
72.0
62.4
45.8
40.4
--
90V,
60Hz
(Label
up)
3.31
62.8
86.2
104.3
96.1
100.2
75.3
90.1
89.1
86.1
83.9
91.3
91.6
103.4
92.9
104.0
85.8
84.3
79.8
62.4
40.8
--
264V,
60Hz
(Label
up)
2.83
54.8
71.7
78.0
78.7
78.6
69.5
79.0
78.0
78.0
73.4
74.9
77.6
78.6
79.3
84.9
79.5
71.4
69.2
57.0
40.5
--
--
--
-----------------------
-70
130
130
130
130
130
110
110
100
125
100
105
130
130
130
130
130
95
95
---
3.31
57.0
85.6
100.3
90.3
101.4
81.6
88.0
89.0
87.6
84.9
88.7
94.5
2.61
52.1
73.2
78.9
77.5
80.1
75.9
78.7
78.6
81.1
75.3
75.1
84.1
3.41
59.3
88.5
104.3
95.2
104.5
81.2
90.8
92.7
87.0
86.9
93.0
96.6
3.3
53.4
75.1
81.4
80.7
82.3
75.6
80.6
81.2
80.5
76.7
77.9
85.5
--------------
-70
130
130
130
130
130
110
110
100
125
100
105
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 6 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
13.BD1 body
14.PCB under Q2
15. PCB under Q1/D1
16. PCB under Q3
17.MOV1 body
18.Inside Enclosure
19.Outside Enclosure
20.Ambient
Result - Remark
101.6
93.0
100.9
85.8
82.1
76.5
47.2
40.7
temperature T of winding:
79.4
82.2
84.4
81.5
71.6
68.1
45.7
40.7
R1 (Ω)
--
--
105.9
95.7
103.5
86.2
84.7
85.1
63.9
41.0
R2 ( Ω)
--
82.3
83.8
86.1
81.7
73.2
74.6
59.8
41.0
T (°C)
--
Verdict
---------
130
130
130
130
130
95
95
--
allowed
insulation
Tmax (°C)
class
---
supplementary information:
-- The temperatures were measured by thermal couple under worst case normal mode defined in 1.2.2.1 and
described in 1.6.2 at voltages as described in 1.4.5.
-- With maximum ambient temperature specified as 40 degree C, therefore, the maximum temperature is as
follows:
-- Winding components: (thermal couple used)
Class B (Transformers: T1) -> Tmax = 120 - 10 = 110 degree C
-- Components with:
max. absolute temp. of 70 degree C (Inlet).
max. absolute temp. of 100 degree C (U1, CX1);
max. absolute temp. of 105 degree C (C4);
max. absolute temp. of 125 degree C (CY1);
max. absolute temp. of 130 degree C (PWB)
-- User accessible area:
Plastic Enclosure: 95 degree C
4.5.2
N/A
TABLE: ball pressure test of thermoplastics
allowed impression diameter (mm) ........................ :
part
—
test temperature (°C)
supplementary information:
Underwriters Laboratories Inc.
impression diameter
(mm)
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 7 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
4.7
Requirement + Test
Verdict
Pass
TABLE: resistance to fire
part
--
Result - Remark
manufacturer of material
--
type of material
--
thickness(mm)
flammability
class
--
--
supplementary information:
See Critical Components for details.
5.2
Pass
TABLE: electric strength tests, impulse tests and voltage surge tests
test voltage applied between:
test voltage (V)
a.c./d.c.
2.10.5.2, 2.9.5
Transformer/Insulation Electric Strength Test
One layer of insulation Tape for T1
3M Company / 1350T-1, 1350F(#), 44
Bondtec Pacific Co., Ltd. / 370S
Transformer (T1) Primary to Secondary
Transformer (T1) Secondary to Core
5.2.2
Electric Strength Test
Unit Primary to Secondary Output
Unit Primary to Enclosure with foil
Tubing (For HS1 and HS2):
CHANGYUAN ELECTRONICS (SHENZHEN) CO LTD / CBHFT
Tubing for Functional Earthing:
GUANGZHOU KAIHENG ENTERPRISE GROUP / K-2
Insulating Tape (between C10 and Heat Sink (Cover)):
3M Company / 1350T-1
Insulation sheet for Heat Sink (Chassis):
FORMEX,DIV OF IL TOOL WORKS INC,FRMRLY FASTEX,DIV
OF IL TOOL WORKS INC / FORMEX GK
breakdown
Yes / No
--
--
3000 Vac
No
3000 Vac
3000 Vac
--
No
No
--
3000 Vac
3000 Vac
3000 Vac
No
No
No
3000 Vac
No
3000 Vac
No
3000 Vac
No
supplementary information:
--
5.3
TABLE: fault condition tests
Pass
ambient temperature (°C) ....................................... : 25 degree C, if ambient not
specified.
model/type of power supply.................................... : --
—
manufacturer of power supply ................................ : -rated markings of power supply.............................. : --
—
Underwriters Laboratories Inc.
—
⎯
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 8 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
component fault
No.
---
test voltage
(V)
--
--
fuse
No.
--
--
--
--
--
--
fuse current
(A)
5.3.1, 5.3.4,
5.3.6
--
BD1
Short
1sec
FS1
0.438 to 0
C4
Short
1sec
FS1
0.438 to 0
NB,NC,NT,CD(FS1) (b)
Q3
Short
1sec
FS1
0.438 to 0.26
NB,NC,NT,IP(US2) (a)
U1 Pin 1-2
Short
1sec
FS1
0.438 to 0.045 NB,NC,NT,IP(US2) (a)
U1 Pin 3-4
Short
1sec
FS1
0.438 to 0.044 NB,NC,NT,IP(US2) (a)
U1 Pin 1
Open
1sec
FS1
0.438 to 0.043 NB,NC,NT,IP(US2) (a)
U1 Pin 3
Open
1sec
FS1
0.438 to 0.043 NB,NC,NT,IP(US2) (a)
Q1(G-D)
Short
1sec
FS1
0.442 to 0
Q1(D-S)
Short
1sec
FS1
0.440 to 0
Q1(G-S)
Short
6.5hrs
FS1
0.699
Q2(G-D)
Short
1sec
FS1
0.440 to 0
Q2(D-S)
Short
1sec
FS1
Q2(G-S)
Short
1sec
FS1
R1
Short
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
Model:
GT-41069P9012-T3YZ.
NB,NC,NT,CD(FS1) (b)
4.1hrs
FS1
R2
Short
1sec
FS1
US1 Pin 56
US1 Pin 67
US2 Pin 26
US2 Pin 46
US2 Pin 56
Short
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
0.962 to 0.054 NB,NC,NT, Unit shutdown
after fault condition at 90
mins.
0.438 to 0.042 NB,NC,NT,IP(US2) (a)
3.4hrs
FS1
0.703
NB,NC,NT, (c)
4.2hrs
FS1
0.712
NB,NC,NT, (c)
1sec
FS1
0.439 to 0.042 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.042 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.042 NB,NC,NT,IP(US2) (a)
Short
Short
Short
Short
test time
Verdict
result
Component Failure Test
NB,NC,NT,CD(FS1,Q1,R1)
(b)
NB,NC,NT,CD(FS1,Q1,R1)
(b)
NB,NC,NT, (c)
NB,NC,NT,CD(FS1,Q2,R2)
(b)
0.439 to 0
NB,NC,NT,CD(FS1,Q2,R2)
(b)
0.439 to 0.041 NB,NC,NT,IP(US2) (a)
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 9 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
US2 Pin 3
Open
US3 Pin 56
US3 Pin 67
--
Short
--
--
240Vac/
60Hz
240Vac/
60Hz
240Vac/
60Hz
--
--
Short
T1 after Q3 Short
T1 after Q3 Overload
--
--
T1 after Q3 Short
T1 after Q3 Overload
--
Result - Remark
--
T1 after Q3 Short
T1 after Q3 Overload
Verdict
1sec
FS1
0.439 to 0.041 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.052 NB,NC,NT,IP(US2) (a)
1sec
FS1
0.439 to 0.052 NB,NC,NT,IP(US2) (a)
--
--
--
--
--
5.3.3, 5.3.6b,
Annex C.1
--
240Vac/
60Hz
240Vac/
60Hz
10min
FS1
10.8hr
FS1
--
--
--
240Vac/
60Hz
240Vac/
60Hz
10min
FS1
0.471 to 0.045 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 8.0A,
T1 coil:113.4 degree C,
T1 core:106.5 degree C,
Amb:23.8 degree C, no
hazards.
-Model:
GT-41069P9019-T3YZ.
0.431 to 0.158 NB,NC,NT,IP(US2) (a)
10.5hr
FS1
0.490 to 0.04
--
--
--
240Vac/
60Hz
240Vac/
60Hz
10min
FS1
9.8hr
FS1
Transformer Abnormal
Operation Test
Model:
GT-41069P9012-T3YZ.
0.438 to 0.176 NB,NC,NT,IP(US2) (a)
NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 5.44A,
T1 coil:94.6 degree C,
T1 core:90.0 degree C,
Amb:24.0 degree C, no
hazards.
-Model:
GT-41069P9024-T3YZ.
0.429 to 0.146 NB,NC,NT,IP(US2) (a)
--
--
--
--
--
--
--
--
--
--
Output
Short
10min
FS1
Output
Overload
240Vac/
60Hz
240Vac/
0.562 to 0.042 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 5.05A,
T1 coil:101.0 degree C,
T1 core:96.9 degree C,
Amb:23.3 degree C, no
hazards.
5.3.6
Power Supply Output ShortCircuit/ Overload
-Model:
GT-41069P9012-T3YZ.
0.436 to 0.172 NB,NC,NT,IP(US2) (a)
9hr
FS1
0.485 to 0.041 NB,NC,NT,IP(US2),unit
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Amendment 1
2008-12-19
Page 10 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
60Hz
--
--
--
--
--
Output
Short
10min
FS1
Output
Overload
240Vac/
60Hz
240Vac/
60Hz
10.3hr
FS1
--
--
--
--
--
Output
Short
10min
FS1
Output
Overload
240Vac/
60Hz
240Vac/
60Hz
10.4hr
FS1
Verdict
shutdown,while the output
loaded to 8.4A,
T1 coil:102.1, degree C,
T1 core:96.5 degree C,
Amb:24.2 degree C, no
hazards.
-Model:
GT-41069P9019-T3YZ.
0.427 to 0.156 NB,NC,NT,IP(US2) (a)
0.479 to 0.041 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 5.34A,
T1 coil:99.6, degree C,
T1 core:92.1 degree C,
Amb:25.5 degree C, no
hazards.
-Model:
GT-41069P9024-T3YZ.
0.429 to 0.146 NB,NC,NT,IP(US2) (a)
0.556 to 0.043 NB,NC,NT,IP(US2),unit
shutdown,while the output
loaded to 4.95A,
T1 coil:100.7, degree C,
T1 core:95.5 degree C,
Amb:25.3 degree C, no
hazards.
supplementary information:
Comments Key: IP - Internal protection operated (list component). CT - Constant temperatures were obtained.
TW - Transformer winding opened. CD - Components damaged (list damaged components). NB - No indication
of dielectric breakdown. YB - Dielectric breakdown (indicate time and location). NC - Cheesecloth remained
intact. YC - Cheesecloth charred or flamed. NT - Tissue paper remained intact. YT - Tissue paper charred or
flamed. (a) - Unit shutdown instantly. (b) - Fuse open instantly. (c) - Unit operated normally and no hazard, no
damaged. Component Failure Test: Test items interrupted by the opening of Fuse (FS1) were repeated with
following source. (1) WALTER ELECTRONIC CO LTD / ICP, (2) DAS & SONS INTERNATIONAL LTD /
385T1315, (3) Conquer Electronics Co Ltd / MST, (4) SAVE FUSETECH INC / SS-5.
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 1 of 10
Report Reference #
Enclosure
National Differences
USA / Canada
Underwriters Laboratories Inc.
E170507-A26-UL-1
Issue Date:
2008-10-28
Page 2 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
USA / Canada - Differences to IEC 60950-1:2001, First Edition
1.1
Equipment able to be installed in accordance with
the National Electrical Code ANSI/NFPA 70 and
the Canadian Electrical Code, Part1, and when
applicable, the National Electrical Safety Code,
IEEE C2.
Pass
1.1.1
Equipment able to be installed in accordance with
ANSI/NFPA 75 and NEC Art. 645 unless intended
for use outside of computer room and provided with
such instructions.
Pass
1.1.2
Equipment in wire-line communication facilities
serving high-voltage electric power stations
operating at greater than 1kV are excluded.
N/A
1.1.2
Special requirements apply to equipment intended
for use outdoors.
N/A
1.4.14
For Pluggable Equipment Type A, the protection in
the installation is assumed to be 20 A.
Pass
1.5.1
All IEC standards for components identified in
Annex P.1 replaced by the relevant requirements of
CSA and UL component standards in Annex P.1.
Pass
1.5.1
All IEC standards for components identified in
Annex P.2 alternatively satisfied by the relevant
requirements of CSA and UL component standards
in Annex P.2.
Pass
1.5.5
Interconnecting cables acceptable for the
INTERCONNECTING
application regarding voltage, current, temperature, CABLES used complied with
flammability, mechanical serviceability and the like. the relevant requirements of
this standard.
Pass
1.5.5
For other than limited power and TNV circuits, the
type of output circuit identified for output connector.
N/A
1.5.5
External cable assemblies that exceed 3.05 m in
length to be types specified in the NEC and CEC.
N/A
1.5.5
Detachable external interconnecting cables 3.05 m
or less in length and provided with equipment
marked to identify the responsible organization and
the designation for the cable.
N/A
1.5.5
Building wiring and cable for use in ducts, plenums
and other air handling space subject to special
requirements and excluded from scope.
N/A
1.5.5
Telephone line and extension cords and the like
comply with UL 1863 and CSA C22.2 No. 233.
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 3 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
1.6.1.2
Equipment intended for connection to a d.c. power
(mains) distribution system is subject to special
circuit classification requirements (e.g., TNV-2)
N/A
1.6.1.2
Earthing of d.c. powered equipment provided.
N/A
1.7
Lamp replacement information indicated on
lampholder in operator access area.
N/A
1.7.1
Special marking format for equipment intended for
use on a supply system with an earthed neutral
and more than one phase conductor.
N/A
1.7.1
Equipment voltage rating not higher than rating of
the plug except under special conditions.
N/A
1.7.6
Special fuse replacement marking for operator
accessible fuses.
N/A
1.7.7
Identification of terminal connection of the
equipment earthing conductor.
N/A
1.7.7
Connectors and field wiring terminals for external
Class 2 or Class 3 circuits provided with marking
indicating minimum Class of wiring to be used.
N/A
1.7.7
Marking located adjacent to terminals and visible
during wiring.
N/A
2.1.1
Screw shell of Edison-base lampholder tied to the
neutral conductor.
N/A
2.1.1.1
Bare TNV conductive parts in the interior of
equipment normally protected against contact by a
cover intended for occasional removal are exempt
provided instructions include directions for
disconnection of TNV prior to removal of the cover.
N/A
2.3.1.b
Other telecommunication signaling systems (e.g.,
message waiting) than described in 2.3.1(b) are
subject to M.4.
N/A
2.3.1.b
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 V d.c., the maximum current limit through
a 2000 Ohm or greater resistor with loads
disconnected is 7.1 mA peak or 30 mA d.c. under
normal conditions.
N/A
2.3.1.b
Limits for measurements across 5000 ohm resistor
in the event of a single fault are replaced after 200
ms with the limits of M.3.1.4.
N/A
2.3.2
Enamel coating on signal transformer winding wire
allowed as an alternative to Basic insulation in
specific telecommunication applications when
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 4 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
subjected to special construction requirements and
routine testing.
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV circuits and accessible conductive
parts.
N/A
2.5
Overcurrent protection device required for Class 2
and Class 3 limiting in accordance with the NEC, or
for a Limited Power Source, not interchangeable
with devices of higher ratings if operator
replaceable.
N/A
2.6
Equipment having receptacles for output a.c. power
connectors generated from an internal separately
derived source have the earthed (grounded) circuit
conductor suitably bonded to earth.
N/A
2.6.3.3
For Pluggable Equipment Type A, if neither a) or b)
are applicable, the current rating of the circuit is
taken as 20 A.
N/A
2.6.3.4
Capacity of connection between earthing terminal
and parts required to be earthed subject to special
conditions based on the current rating of the circuit.
N/A
2.6.3.4
Protective bonding conductors and their terminals
of non-standard constructions (e.g. PWB traces)
evaluated to limited short-circuit test of CSA C22.2
No.0.4.
N/A
2.6.4.1
Field wiring terminals for earthing conductors
suitable for wire sizes (gauge) used in US and
Canada.
N/A
2.7.1
Data for selection of special external branch circuit
overcurrent devices marked on the equipment.
N/A
2.7.1
Standard supply outlets protected by overcurrent
device in accordance with the NEC, and CEC, Part
1.
N/A
2.7.1
Overcurrent protection for individual transformers
that distribute power to other units over branch
circuit wiring.
N/A
2.7.1
Additional requirements for overcurrent protection
apply to equipment provided with panelboards.
N/A
2.7.1
Non-motor-operated equipment requiring special
overcurrent protective device marked with device
rating.
N/A
2.10.5.4
Multi-layer winding wire subject to UL component
wire requirements in addition to 2.10.5.4 and
Pass
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 5 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
Annex U.
3.1.1
Permissible combinations of internal wiring/external All internal wires possess
cable sizes for overcurrent and short circuit
adequate cross-sectional
protection.
areas for their intended
application and all internal
wirings are adequately
insulated.
Pass
3.1.1
All interconnecting cables protected against
overcurrent and short circuit.
Pass
3.2
Wiring methods permit connection of equipment to
primary power supply in accordance with the NEC
and CEC, Part 1.
Pass
3.2.1
Permitted use for flexible cords and plugs.
Pass
3.2.1
Flexible cords provided with attachment plug rated
125% of equipment current rating.
Pass
3.2.1
Any Class II equipment provided with 15 or 20 A
standard supply outlets, Edison-base lampholders
or single pole disconnect device provided with a
polarized type attachment plug.
N/A
3.2.1.2
Equipment intended for connection to DC mains
supply power systems complies with special wiring
requirements (e.g., no permanent connection to
supply by flexible cord).
N/A
3.2.1.2
Equipment with one pole of the DC mains supply
connected to both the equipment mains input
terminal and the main protective earthing terminal
provided with special instructions and construction
provisions for earthing
N/A
3.2.1.2
Equipment with means for connecting supply to
earthing electrode conductor has no switches or
protective devices between supply connection and
earthing electrode connection.
N/A
3.2.1.2
Special markings and instructions for equipment
with provisions to connect earthed conductor of a
DC supply circuit to earthing conductor at the
equipment.
N/A
3.2.1.2
Special markings and instructions for equipment
with earthed conductor of a DC supply circuit
connected to the earthing conductor at the
N/A
All INTERCONNECTING
CABLES possess adequate
cross-sectional areas for their
intended application and all
internal wirings are adequately
insulated.
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 6 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
equipment.
3.2.1.2
Terminals and leads provided for permanent
connection of DC powered equipment to supply
marked to indicate polarity if reverse polarity may
result in a hazard.
N/A
3.2.3
Permanently connected equipment has provision
for connecting and securing a field wiring system
(i.e. conduit, or leads etc.) per the NEC and CEC,
Part 1.
N/A
3.2.3
Permanently connected equipment may have
terminals or leads not smaller than No. 18 AWG
(0.82 mm²) and not less than 152 mm in length for
connection of field installed wiring.
N/A
3.2.3
If supply wires exceed 60 °C, marking indicates
use of 75 °C or 90 °C wiring for supply connection
as appropriate.
N/A
3.2.3
Equipment compatible with suitable trade sizes of
conduits and cables.
N/A
3.2.5
Length of power supply cord limited to between 1.5
and 4.5 m unless shorter length used when
intended for a special installation.
Pass
3.2.5
Conductors in power supply cords sized according
to NEC and CEC, Part I.
Pass
3.2.5
Power supply cords and cord sets incorporate
flexible cords suitable for the particular application.
Pass
3.2.6
Strain relief provided for non-detachable
interconnecting cables not supplied by a limited
power source.
Pass
3.2.9
Adequate wire bending space and volume of field
wiring compartment required to properly make the
field connections.
N/A
3.2.9
Equipment intended solely for installation in
Restricted Access Locations using low voltage d.c.
systems may not need provision for connecting and
securing a field wiring system. A method of
securing wiring or instructions provided to ensure
the wiring is protected from abuse.
N/A
3.3
Field wiring terminals provided for interconnection
of units for other then LPS or Class 2 circuits also
comply with 3.3.
N/A
3.3
Interconnection of units by LPS or Class 2
conductors may have field wiring connectors other
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 7 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
than those specified in 3.3 if wiring is reliably
separated.
3.3.1
Terminals for the connection of neutral conductor
identified by a distinctive white marking or other
equally effective means.
N/A
3.3.3
Wire binding screw terminal permitted for
connection of No. 10 AWG (5.3 mm²) or smaller
conductor if provided with upturned lugs, cupped
washer or equivalent retention.
N/A
3.3.4
Terminals accept wire sizes (gauge) used in the
U.S. and Canada.
N/A
3.3.4
Terminals accept current-carrying conductors rated
125% of the equipment current rating.
N/A
3.3.6
Field wiring terminals marked to indicate the
material(s) of the conductor appropriate for the
terminals used.
N/A
3.3.6
Connection of an aluminum conductor not
permitted to terminal for equipment earthing
conductor.
N/A
3.3.6
Field wiring connections made through the use of
suitable pressure connectors (including set screw
type), solder lugs or splices to flexible leads.
N/A
3.4.2
Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with
motor rated more than 1/3 hp or more than 120 V.
N/A
3.4.8
Vertically mounted disconnect devices oriented so
up position of handle is "on".
N/A
3.4.11
For computer-room applications, equipment with
battery systems capable of supplying 750 VA for 5
min require battery disconnect means.
N/A
4.2.8.1
Special opening restrictions for enclosures around
CRTs with face dimension of 160 mm or more.
N/A
4.2.9
Compartment housing high-pressure lamp marked
to indicate risk of explosion.
N/A
4.3.2
Loading test for equipment with handle(s) used to
support more than 9 kg tested at four times the
weight of the unit.
N/A
4.3.6
In addition to the IEC requirements, Direct Plug-in
Equipment complies with UL 1310 or CSA 223
mechanical assembly requirements.
N/A
4.3.12
The maximum quantity of flammable liquid stored
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 8 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
in equipment complies with ANSI/NFPA 30(Table
NAE.6).
4.3.12
Equipment using replenishable liquids marked to
indicate type of liquid to be used.
N/A
4.3.13.2
Equipment that produces x-radiation and does not
comply with 4.3.12 under all conditions of servicing
marked to indicate the presence of radiation where
readily visible.
N/A
4.3.13.5
Requirements contained in the applicable national
codes and regulations apply to lasers (21 CFR
1040 and REDR C1370).
N/A
4.7
Automated information storage equipment intended
to contain more than 0.76 m³ of combustible media
requires provision for automatic sprinklers or a
gaseous agent extinguishing system.
N/A
4.7.3.1
Equipment for use in environmental air space other
than ducts or plenums provided with metal
enclosure or with non-metallic enclosure having
adequate fire-resistance and low smoke producing
characteristics. Low smoke-producing
characteristics evaluated according to UL 2043.
Equipment for installation in space used for
environmental air as described in Sec. 300-22(c) of
the NEC provided with instructions indicating
suitability for installation in such locations.
N/A
4.7.3.1
Flame spread rating for external surface of
combustible material with exposed area greater
than 0.93 m² or a single dimension greater than 1.8
m; 50 or less for computer room applications or
200 or less for other applications.
N/A
4.7.3.4
Wire marked "VW-1" or "FT-1" considered
equivalent.
Pass
5.1.8.2
Special earthing provisions and instructions for
equipment with high touch current due to
telecommunication network connections.
N/A
5.1.8.3
Touch current due to ringing voltage for equipment
containing telecommunication network leads.
N/A
5.3.6
Overloading of SELV connectors and printed wiring
board receptacles accessible to the operator.
N/A
5.3.6
Tests interrupted by opening of a component
repeated two additional times.
N/A
5.3.8.1
Test interrupted by opening of wire or trace subject
to certain conditions.
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 9 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
6
Specialized instructions provided for telephones
that may be connected to a telecommunications
network.
N/A
6
Marking identifying function of telecommunication
type connectors not used for connection to a
telecommunication network.
N/A
6.2.1
Special requirements for enameled wiring used as
electrical separation provided between parts
connected to telecommunication network and
telecommunication circuitry intentionally isolated
from network.
N/A
6.2.1
Digital line termination equipment (e.g., NCTE)
subject to separation requirements.
N/A
6.3
Equipment remotely powered over
telecommunication wiring systems provided with
specialized markings adjacent to the connection.
N/A
6.3
Overcurrent protection incorporated into equipment
to provide power over telecommunication wiring
system not interchangeable with devices of higher
ratings if operator replaceable.
N/A
6.4
Additional requirements for equipment intended for
connection to a telecommunication network using
cable subject to overvoltage from power line
failures (Fig. 6C).
N/A
6.4
Where 26 AWG line cord required by Fig. 6C,
either the cord is provided with the equipment or
described in the safety instructions.
N/A
6.5
Acoustic pressure from an ear piece less than 136
dBA for short duration disturbances, and less than
125 dBA for handsets, 118 dBA for headsets, and
121 dBA for insert earphones, for long duration
disturbances.
N/A
7
Equipment associated with the cable distribution
system may need to be subjected to applicable
parts of Chapter 8 of the NEC.
N/A
H
Ionizing radiation measurements made under
single fault conditions in accordance with the
requirements of the Code of Federal Regulations
21 CFR 1020 and the Canadian Radiation Emitting
Devices Act, REDR C1370.
N/A
M.2
Continuous ringing signals evaluated to Method A
subjected to special accessibility considerations.
N/A
Underwriters Laboratories Inc.
Issue Date:
2008-10-28
Page 10 of 10
Report Reference #
E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test
Result - Remark
Verdict
M.4
Special requirements for message waiting and
similar telecommunications signals.
N/A
NAC
Equipment intended for use with a generic
secondary protector marked with suitable
instructions.
N/A
NAC
Equipment intended for use with a specific primary
or secondary protector marked with suitable
instructions.
N/A
NAF
Household/Home Office Document Shredders
N/A
NAF.1.7
Markings and instructions alert the user to key
safety considerations related to use of shredders,
including not intended to be used by children, avoid
touching document feed opening, avoid clothes
and hair entanglement, and avoid aerosol products.
N/A
NAF.2.8.3
Safety interlock cannot be inadvertently activated
by the articulated accessibility probe (figure
NAF.1).
N/A
NAF.3.4
Provided with an isolating switch complying with
3.4.2, including 3 mm contact gap, with appropriate
markings associated with the switch.
N/A
NAF.4.4
Hazardous moving parts are not accessible to the
user, as determined using the articulated
accessibility probe (figure NAF.1) and the
accessibility probe/wedge (figures NAF.2/NAF.3).
N/A