Vaisala HUMICAP MMT310 Datasheet

Vaisala HUMICAP MMT310 Datasheet
HUMIDITY / DEW POINT /
MOISTURE IN OIL / CARBON DIOXIDE /
OXYGEN / BAROMETRIC PRESSURE / WIND
Vaisala – at your service
We at Vaisala have always valued the opportunity to push ourselves and our products to
a higher level for the benefit of our customers. Our new strategy nurtures this opportunity,
allowing us to focus on customers who operate in tightly controlled and demanding areas
in the chosen industrial applications introduced in this catalog. We are confident that
concentrating Vaisala's product and business development efforts on these areas will result in
the overall success of our customers.
The very core of Vaisala still is our unique devotion to products: the stability, reliability
and performance that we have always been known and recognized for. With over 70
years of experience, close to 30 offices worldwide and thousands of customers in over 120
countries, Vaisala is an esteemed leader in innovating, manufacturing and servicing highquality instruments and systems. Our products have been designed to meet the customers'
measurement needs in the most demanding industrial processes and controlled environments.
This catalog introduces Vaisala's measurement instrument offering for industrial customers.
Our professional sales force all over the world is at your service, ready to help you choose just
the right solution for your specific measurement needs.
I wish you every success with your business – we are at your service.
Solutions to HVAC&R
measurement needs
Vaisala serves building automation customers in a
variety of HVAC&R measurement needs, providing
the best solutions for energy optimization,
Indoor Air Quality (IAQ) and Demand Controlled
Ventilation (DCV)in diverse and demanding
environments. Whether you are an OEM, integrator,
contractor, or responsible for facility HVAC
management, we have an answer to your specific
business needs. See Building Automation offering, page 6.
Efficiency and productivity in
controlled environments
Our cleanrooms and chambers group can help you
increase the efficiency and productivity of your
operations in controlled environments. Whatever the
industry – life science, food, microelectronics,
automotive, you name it – cleanrooms & dryrooms,
laboratories, incubators, environmental test chambers,
warehouses and various other critical environments all
benefit from Vaisala's solutions that minimize downtime
and maximize yield. See Cleanrooms and Chambers
offering, pages 7-8.
Improved industrial processes
Many industries, such as power, pharmaceutical, marine and
plastics industries, benefit from the wide range of Vaisala's
measurement instruments. Accurate, stable and reliable
measurements can improve your industrial processes,
energy efficiency and end-product quality. Applications in
which Vaisala measurement instruments and our excellent
services help our customers include e.g. monitoring the
quality of compressed air, lubricating and transformer oils,
as well as controlling various drying processes . See Targeted
Industrial Applications offering, pages 8-9.
A job well done
In any industrial environment, installing the best quality
solutions – on time and on budget – can pose a real
challenge. By drawing on our application knowledge and
product expertise you can always rely on getting just the
right solution for your needs.
Vaisala’s offering ranges from lightweight, hand-held
instruments and OEM models to configurable fixed
transmitters designed to meet the most stringent of
demands. The standard delivery time for a configured
product is three business days. For re-calibration, our
regional Service Centers offer express services. See Service
offering, pages 148-157.
Kenneth Forss
Executive Vice President
Controlled Environment
Vaisala
Go to www.vaisala.com for the latest updates and other product news.
2
3
Table of Contents by Parameters
Moisture in Oil
MMT330 Moisture and Temperature Transmitter Series for Oil .................................................................... 86
MMT310 Series Moisture and Temperature Transmitter for Oil..................................................................... 92
MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM Applications ................................. 94
Humidity
MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in Oil ................................................ 96
HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10
HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14
Carbon Dioxide
HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15
GMP343 Carbon Dioxide Probe for Demanding Measurements..................................................................... 98
HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16
GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100
HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17
GMM220 Carbon Dioxide Modules forDemanding OEM Applications ...........................................................102
HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18
GMM111 Carbon Dioxide Module .............................................................................................................. 104
HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19
GM70 Hand-Held Carbon Dioxide Meterfor Spot-Checking Applications ..................................................... 106
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20
GMW115 Carbon Dioxide Transmitter for Demand-controlled Ventilation ................................................... 108
HMT310 Humidity and Temperature Transmitter ........................................................................................ 26
GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications .................. 110
HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28
GMM112 Carbon Dioxide Module for HVAC Applications ..............................................................................112
DMW19 Wall Mount Dewpoint Transmitters for Indoor Applications............................................................. 30
GMM20W Carbon Dioxide Modulefor OEM Applications ............................................................................. 114
HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32
GML20 and GML20T LonWorks® Options for GMD/W20 Series ................................................................... 116
HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34
HMW40/50 and HMD40/50 Wall and Duct Mount Transmitters for HVAC Applications ................................... 36
Oxygen
HMM210 Series Humidity Modules for Environmental Chambers ................................................................. 38
OMT355 Oxygen Transmitter for Industrial Process Measurements ............................................................ 118
HMM100 Humidity Module for Environmental Chambers ............................................................................40
OMT364 Oxygen Transmitter for Hazardous Areas .................................................................................... 122
HMP60 Humidity and Temperature Probe .................................................................................................. 42
HMP110 Humidity and Temperature Probe ................................................................................................. 44
Barometric Pressure
HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46
PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications ..............124
HMI41 Indicator and HMP46 High Temperature Probe ................................................................................. 48
PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users ...............................130
HMP41, HMP42 and HMP45 Probes for HMI41 Indicator ................................................................................ 50
PTB330TS Barometric Pressure Transfer Standard - Take the Lab to the Field ............................................. 132
HM34 Pocket Size Relative Humidity Meter ................................................................................................. 52
PTB330TS Barometric Pressure Transfer Standard .....................................................................................134
HMK15 Humidity Calibrator ........................................................................................................................ 54
PTB210 Digital Barometer .......................................................................................................................... 136
HMP155 Humidity and Temperature Probe .................................................................................................. 56
PTB110 Barometer for Industrial Use .......................................................................................................... 138
DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58
SPH10/20 Static Pressure Heads for Minimizing Wind Induced Error ........................................................... 140
HMD60UO/YO Outdoor Humidity and Temperature Transmitter & Solar Radiation Shield ............................. 60
HMT330MIK Meteorological Installation Kit ................................................................................................ 62
Wind
HMT300TMK Turbine Mounting Kit for Power Turbine Intake Air Measurement............................................ 64
WXT520 Weather Transmitter ....................................................................................................................142
WMT52 Ultrasonic Wind Sensor for Accurate and Stable Measurement ...................................................... 144
Dew Point
WA15 Wind Set for High Performance Wind Measurement...........................................................................146
DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions ........................................ 66
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications ........................................ 72
DMT242 Dewpoint Transmitter for OEM Applications .................................................................................. 76
DMT152 Dewpoint Transmitter for Low Dewpoint Measurement in OEM Applications .................................. 78
DMT142 Miniature Dewpoint Transmitter for OEM Applications ................................................................... 80
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications................................................................ 82
DSS70A Portable Sampling System and Sampling Cells for DM70................................................................... 84
4
Vaisala Service Offering .................................................................................................................148
Calibration is Our Core Operation .............................................................................................. 151
Spare Filters ....................................................................................................................................... 158
Pricing for Configurable Products .............................................................................................. 161
Pricing for Standard, Non-Configurable Products ............................................................... 217
Vaisala Contact Information ......................................................................................................... 219
5
Table of Contents by Focus Area
Building Automation
Cleanrooms and Chambers
HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10
HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10
HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14
HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14
HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15
HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15
HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16
HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16
HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17
HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17
HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18
HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18
HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19
HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20
HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28
HMT310 Humidity and Temperature Transmitter ........................................................................................ 26
DMW19 Wall Mount Dewpoint Transmitters for Indoor Applications............................................................. 30
HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28
HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32
HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32
HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34
HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34
HMW40/50 and HMD40/50 Wall and Duct Mount Transmitters for HVAC Applications ................................... 36
HMM210 Series Humidity Modules for Environmental Chambers ................................................................. 38
HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46
HMM100 Humidity Module for Environmental Chambers ............................................................................40
HMI41 Indicator and HMP46 High Temperature Probe ................................................................................. 48
HMP60 Humidity and Temperature Probe .................................................................................................. 42
HMP41, HMP42 and HMP45 Probes for HMI41 Indicator ................................................................................ 50
HMP110 Humidity and Temperature Probe ................................................................................................. 44
HM34 Pocket Size Relative Humidity Meter ................................................................................................. 52
HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46
HMK15 Humidity Calibrator ........................................................................................................................ 54
HMI41 Indicator and HMP46 High Temperature Probe ................................................................................. 48
HMP155 Humidity and Temperature Probe .................................................................................................. 56
HMP41, HMP42 and HMP45 Probes for HMI41 Indicator ................................................................................ 50
DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58
HM34 Pocket Size Relative Humidity Meter ................................................................................................. 52
HMD60UO/YO Outdoor Humidity and Temperature Transmitter & Solar Radiation Shield ............................. 60
HMK15 Humidity Calibrator ........................................................................................................................ 54
GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100
HMP155 Humidity and Temperature Probe .................................................................................................. 56
GM70 Hand-Held Carbon Dioxide Meterfor Spot-Checking Applications ..................................................... 106
DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58
GMW115 Carbon Dioxide Transmitter for Demand-controlled Ventilation ................................................... 108
DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions ........................................ 66
GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications .................. 110
DMT242 Dewpoint Transmitter for OEM Applications .................................................................................. 76
GMM112 Carbon Dioxide Module for HVAC Applications ..............................................................................112
DMT152 Dewpoint Transmitter for Low Dewpoint Measurement in OEM Applications .................................. 78
GMM20W Carbon Dioxide Module for OEM Applications ............................................................................ 114
DMT142 Miniature Dewpoint Transmitter for OEM Applications ................................................................... 80
GML20 and GML20T LonWorks Options for GMD/W20 Series ................................................................... 116
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications................................................................ 82
SPH10/20 Static Pressure Heads for Minimizing Wind Induced Error ........................................................... 140
GMP343 Carbon Dioxide Probe for Demanding Measurements..................................................................... 98
WXT520 Weather Transmitter ...................................................................................................................142
GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100
WMT52 Ultrasonic Wind Sensor for Accurate and Stable Measurement ...................................................... 144
GMM220 Carbon Dioxide Modules for Demanding OEM Applications ..........................................................102
®
WA15 Wind Set for High Performance Wind Measurement...........................................................................146
Service offering, pages 148–157
6
7
Cleanrooms and Chambers continued
Targeted Industrial Applications continued
GMM111 Carbon Dioxide Module .............................................................................................................. 104
HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46
GM70 Hand-Held Carbon Dioxide Meterfor Spot-Checking Applications ..................................................... 106
HMK15 Humidity Calibrator ........................................................................................................................ 54
GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications .................. 110
DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58
OMT355 Oxygen Transmitter for Industrial Process Measurements ............................................................ 118
HMT330MIK Meteorological Installation Kit ................................................................................................ 62
PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications ..............124
HMT300TMK Turbine Mounting Kit for PowerTurbine Intake Air Measurement ............................................. 64
PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users ...............................130
DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions ........................................ 66
PTB330TS Barometric Pressure Transfer Standard - Take the Lab to the Field ............................................. 132
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications ........................................ 72
PTB330TS Barometric Pressure Transfer Standard .....................................................................................134
DMT242 Dewpoint Transmitter for OEM Applications .................................................................................. 76
PTB210 Digital Barometer .......................................................................................................................... 136
DMT152 Dewpoint Transmitter for Low Dewpoint Measurement in OEM Applications .................................. 78
PTB110 Barometer for Industrial Use .......................................................................................................... 138
DMT142 Miniature Dewpoint Transmitter for OEM Applications ................................................................... 80
WXT520 Weather Transmitter ...................................................................................................................142
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications................................................................ 82
DSS70A Portable Sampling System and Sampling Cells for DM70................................................................... 84
Service offering, pages 148–157
MMT330 Moisture and Temperature Transmitter Series for Oil .................................................................... 86
MMT310 Series Moisture and Temperature Transmitter for Oil..................................................................... 92
MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM Applications ................................. 94
MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in Oil ................................................ 96
GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100
Targeted Industrial Applications
GMM220 Carbon Dioxide Modules for Demanding OEM Applications ..........................................................102
HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10
GMM111 Carbon Dioxide Module .............................................................................................................. 104
HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14
GMM112 Carbon Dioxide Module for HVAC Applications ..............................................................................112
HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15
OMT355 Oxygen Transmitter for Industrial Process Measurements ............................................................ 118
HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16
OMT364 Oxygen Transmitter for Hazardous Areas .................................................................................... 122
HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17
PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications ..............124
HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18
PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users ...............................130
HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19
PTB330TS Barometric Pressure Transfer Standard - Take the Lab to the Field ............................................. 132
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20
PTB330TS Barometric Pressure Transfer Standard .....................................................................................134
HMT310 Humidity and Temperature Transmitter ........................................................................................ 26
HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28
Service offering, pages 148–157
HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32
HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34
8
9
Humidity
www.vaisala.com
HMT330 Series Humidity and Temperature
Transmitters for demanding humidity measurement
Graphical display of
history and measurement
trends
The HMT330 can be ordered with
a large numerical and graphical
display, which allows the user to
clearly monitor operational data,
measurement trends and 1-year
measurement history. The optional
data logger with real-time clock
makes it possible to generate over
four years of measured history, and
zoom in on any desired time or time
frame. The battery backup of the
clock guarantees a reliable logging of
measured data.
The display alarm allows tracking
of any measured parameter, with a
freely configurable low and high limit.
Data collection and
(wireless) transfer to PC
The recorded measurement data
can be viewed on the display or
transferred to a PC with Microsoft
Windows® software. The transmitter
can also be connected to a network
with an optional (W)LAN interface,
which enables a (wireless) Ethernet
connection. A USB-RJ45 cable makes
it easy to connect the service port of
the HMT330 to a PC.
Many ways to install and
versatile outputs
Mains and DC power options, and
several mounting accessories make
the instrument easy to install.
analog outputs. Isolated galvanic
power supply and analog outputs are
also available. For serial interface the
USB connection, RS232 and RS485
can be used.
Flexible calibration
The HMT330 instruments are
calibrated at six humidity points at
the factory. A quick, one-point field
calibration can be performed with
the hand-held HM70 meter. A twopoint calibration can be performed
with the HMK15 salt bath calibrator
in a controlled environment. The
transmitter can be sent to Vaisala for
recalibration. Accredited calibrations
and maintenance contracts are also
available.
The HMT330 can have up to three
The HMT330 transmitter family has the solution for demanding industrial humidity
measurements.
Features/Benefits
▪
Six models for demanding
industrial applications
▪
Full 0 ... 100 %RH
measurement, temperature
range up to +180 °C (+356 °F)
(depending on model)
▪
Pressure tolerance up to
100 bar (depending on model)
▪
Next generation Vaisala
HUMICAP® Sensor for excellent
accuracy and stability
▪
Graphical display of
measurement trends and over
four-year history
▪
▪
Multilingual user interface
▪
Corrosion resistant IP65
housing
▪
NIST traceable (certificate
included)
▪
Analog outputs, WLAN/LAN
10
The Vaisala HUMICAP® Humidity
and Temperature Transmitter
Series HMT330 is designed for
demanding industrial applications
where stable measurement and wide
customization is important.
Vaisala HUMICAP ®
performance
The HMT330 series incorporates
Vaisala’s 30 years of experience in
industrial humidity measurement.
An updated, even more stable and
chemical resistant HUMICAP® sensor
is available, next to the proven
reliable and accurate sensor.
Chemical purge minimizes
effects of contaminants
In environments with high
concentrations of chemicals and
cleaning agents, chemical purge
helps to maintain measurement
accuracy between calibration
intervals.
Chemical purge involves heating the
sensor to remove harmful chemicals.
The function can be initiated
manually or programmed to occur at
set intervals.
Excellent performance in harsh
chemical concentrations
11
Technical data
Performance
Inputs and outputs
Mechanics
Dimensions
RELATIVE HUMIDITY
Operating voltage
10 ... 35 VDC, 24 VAC
with optional power supply module
100 ... 240 VAC, 50/60 HZ
Power consumption at +20 °C (Uin 24 VDC)
RS-232
max. 25 mA
Uout 2 x 0 ... 1 V/0 ... 5 V/0 ... 10 V
max. 25 mA
max. 60 mA
Iout 2 x 0 ... 20 mA
display and backlight
+ 20 mA
during chemical purge
max. 110 mA
during probe heating (HMT337)
+ 120 mA
Analog outputs (2 standard, 3rd optional)
current output
0 ... 20 mA, 4 ... 20 mA
voltage output
0... 1 V, 0... 5 V, 0... 10 V
Accuracy of analog outputs at +20 °C
±0.05% full scale
Temperature dependence of the
analog outputs
±0.005%/°C full scale
External loads
current outputs
RL < 500 ohm
0 ... 1 V output
RL > 2 kohm
0 ... 5 V and 0 ... 10 V outputs
RL > 10 kohm
Max. wire size
0.5 mm2 (AWG 20)
stranded wires recommended
Digital outputs
RS-232, RS-485 (optional)
Service connection
RS-232, USB
Relay outputs (optional)
0.5 A, 250 VAC
Ethernet interface (optional)
Supported standards
10/100Base-T
Connector
RJ45
Protocols
Telnet
Software support
Vaisala MI70 link
WLAN interface (optional)
Supported standards
802.11b
Antenna connector type
RP-SMA
Protocols
Telnet
Security
WEP 64/128,WPA
Software support
Vaisala MI70 link
Authentication / Encryption (WLAN)
Open / no encryption
Open / WEP
WPA Pre shared key / TKIP
WPA Pre shared key / CCMP (a.k.a. WPA2)
Optional data logger with real-time clock
Logged parameters
max. three with trend/min/max values
Logging interval
10 sec (fixed)
Max. logging period
4 years 5 months
Logged points
13.7 million points per parameter
Battery lifetime
min. 5 years
Display
LCD with backlight, graphic trend display
of any parameter
Menu languages
English, Chinese, Japanese, Spanish, German,
French, Swedish, Russian, Finnish
Cable bushing
M20 x 1.5 for cable diameter
Measurement range
8 ... 11 mm/0.31 ... 0.43"
Conduit fitting
1/2" NPT
User cable connector (optional)
M12 series 8-pin (male)
option 1
female plug with 5 m (16.4 ft) black cable
option 2
female plug with screw terminals
Probe cable diameter
HMT333 (+80 °C)
6.0 mm
other probes
5.5 mm
Housing material
G-AlSi 10 Mg (DIN1725)
Housing classification
IP 65 (NEMA4)
Dimensions in mm (inches)
TEMPERATURE
Accuracy at +20 °C (+68 °F)
± 0.2 °C (± 0.36 °F)
Accuracy over temperature range (measurement range
depends on model)
°C
0.7
0.6
0.5
0.4
0.3
0.2
0.1
°C
0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-80
-60
-40
-20
0
20
40
60
80
100
120
140
160
180
Temperature sensor
PT 100 RTD 1/3 Class B IEC 751
Other variables available (depends on model)
dewpoint temperature, mixing ratio, absolute humidity, wet bulb
temperature, enthalpy, water vapor pressure
12
Transmitter with WLAN antenna
183 (7.20)
Operating temperature
for probe
for transmitter body
with display
Electromagnetic compatibility
same as measurement range
-40 ... +60 °C (-40 ... 140 °F)
0 ... +60 °C (32 ... 140 °F)
Complies with EMC standard
EN61326-1, Industrial Environment
116 (4.57)
Operating environment
106 (4.17)
Measurement range
0 ... 100 %RH
Accuracy (including non-linearity, hysteresis, and repeatability)
for typical applications
with Vaisala HUMICAP® 180 or 180R
with Vaisala HUMICAP® 180C or 180RC
for applications with
chemical purge/warmed probe
at +15 ... +25 °C (59 ... +77 °F)
±1 %RH (0 ... 90 %)
±1.7 %RH (90 ... 100 %RH)
at -20 ... +40 °C (-4 ... +104 °F)
±(1.0 + 0.008 x reading) %RH
at -40 ... +180 °C (-40 ... +356 °F)
±(1.5 + 0.015 x reading) %RH
Factory calibration uncertainty (+20 °C)
± 0.6 %RH (0 ... 40 %RH)
± 1.0 %RH (40 ... 97 %RH)
(Defined as ±2 standard deviation limits. Small
variations possible, see also calibration certificate.)
Response time (90 %) at +20 °C (+68 °F) 8 s / 17 s* with grid filter
in still air
20 s / 50 s* with grid + steel netting filter
40 s / 60 s* with sintered filter
* with HUMICAP® 180R or 180RC sensor
Mounting options
Mounting with Wall
Mounting Kit
Mounting with DIN Rail
Installation Kit
Pole Installation with Installation
Kit for Pole or Pipeline
Mounting Rain Shield with
Installation Kit
TYPE APPROVED PRODUCT
CERTIFICATE NO.: A-11440
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210951EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
13
HMT331 Humidity and Temperature Transmitter
for Demanding Wall-Mounted Applications
HMT333 Humidity and Temperature Transmitter
for Ducts and Tight Spaces
210697 duct installation kit for
HMT333 and HMT337.
HMT331 Humidity and Temperature
Transmitter for demanding wallmounted applications
▪
For temperatures -40 ... +60 °C
(-40 ... +140 °F)
▪
Application examples:
cleanrooms, pharmaceutical
processes, greenhouses,
swimming halls, museums and
archives
Technical Data
Temperature measurement range
-40 ... +60 °C (-40 ... +140 °F)
Accessories
PC software + cable
USB-RJ45 Serial Connection Cable
Connection cable for HM70
Wall mounting plate (plastic)
Pole installation kit
Rain shield
DIN rail installation set
Dimensions
Dimensions in mm (inches)
14
215005
219685
211339
214829
215108
215109
215094
The Vaisala HUMICAP® Humidity and
Temperature Transmitter HMT331
is the top-of-the-line wall-mounted
transmitter for demanding HVAC and
condition monitoring applications.
Compared to regular wall-mounted
transmitters, the HMT331 offers,
higher measurement performance,
better chemical tolerance, advanced
graphical display features, more
powering options, more output
options and a wider variety of output
humidity parameters.
Graphical display of
history and
measurement trends
The HMT330 series features a large
numerical and graphical display,
allowing users to easily monitor
operational data, measurement trends
and one-year measurement history.
The optional data logger with realtime clock makes it possible to
generate over four years of measured
history, and zoom in on any desired
time or time frame.
Outputs and power supply
options for every need
Features/Benefits
▪
For remote probe installations
in demanding HVAC
applications
▪
For temperatures -40 ... +80 °C
(-40 ... +176 °F) or
-40 ... +120 °C (-40 ... +248 °F)
▪
Small thermal mass - fast
response to temperature
changes
▪
Application examples:
cleanrooms, pharmaceutical
processes, greenhouses,
environmental chambers
The output options include three
analog outputs, RS-232, RS-485, and
alarm relays.
The voltage supply range is from 10 to
35 VDC. With an additional module,
the transmitter can be connected to
all universal mains AC supplies.
The input/output cable can be fed
through the back of the transmitter,
which is a useful feature, especially
for installations in cleanrooms.
For moderate humidities
and temperatures
The Vaisala HUMICAP® Humidity and
Temperature Transmitter HMT333 is
a versatile instrument for applicatons
where a small remote probe is
needed.
Flexible installation
To install the probe in ducts,
channels and through walls, an
installation kit is available with an
aluminum flange, lead-through piece,
and steel support bar.
HMT333 has two probe cable
options available, a flexible one that
withstands heat up to +80° C, and a
durable cable that withstands heat
up to +120° C. Both cable options are
available in lengths of 2, 5, and 10
meters.
Ø 12 (0.47)
Features/Benefits
The HMT333 transmitter has a small probe for remote applications.
M9x1
The HMT331 is the state-of-the-art wall-mount humidity instrument.
For outdoor environments, the
DTR502B solar radiation shield
provides protection for the probe.
The shield can be installed on a pole,
a beam or a flat surface.
37.5 (1.48)
78.5 (3.09)
98.5 (3.88)
The HMT333 is typically used in
demanding HVAC applications such
as cleanrooms, pharmaceutical
processes, and greenhouses, or in
processes of moderate temperature.
For environments with continuously
high humidity, the HMT337 with a
warmed, vapor-tight and stainless
steel probe is recommended.
Technical Data
Temperature measurement range
-40 ... +80 °C (-40 ... +176 °F) or
-40 ... +120 °C (-40 ... +248 °F)
Accessories
Duct installation kit
210697
Cable gland
HMP247CG
PC software + cable
215005
USB-RJ45 Serial Connection Cable 219685
Connection cable for HM70
211339
Wall mounting plate (plastic)
214829
Pole installation kit
215108
Rain shield
215109
Solar radiation shield
DTR502B
DIN rail installation set
215094
Dimensions
Dimensions in mm (inches)
15
HMT334 Humidity and Temperature Transmitter
for High Pressure and Vacuum Applications
HMT335 Humidity and Temperature Transmitter
for High Temperatures
The installation flange allows an
adjustable installation depth for the
probe.
The display shows measurement
trends and over four-year real time
measurement history.
The HMT335 has a robust stainless steel probe ideal for high flow rates in hot
processes.
Features/Benefits
▪
For pressures up to 100 bar
and vacuum applications
▪
For temperatures
-70 ... +180 °C (-94 ... +356 °F)
▪
▪
ISO and NPT threads available
Application example:
test chambers
Vaisala HUMICAP®
performance
Accessories
Dimensions
Dimensions in mm (inches)
16
210697
17225
215005
219685
211339
214829
215108
215109
215094
M22×1.5 or
NPT 1/2"
Temperature measurement range
-70 ... +180 °C (-94 ... +356 °F)
Operating pressure
0 ... 10 MPa (0 ... 100 bar)
The HMT334 incorporates Vaisala’s
more than 30 years of experience in
industrial humidity measurement.
The sensor provides accurate and
reliable measurement and is immune
to particulate contamination and
most chemicals.
ø12 (0.47)
Technical Data
Fitting body ISO M22 x 1.5
Fitting body NPT 1/2"
PC software + cable
USB-RJ45 Serial Connection Cable
Connection cable for HM70
Wall mounting plate (plastic)
Pole installation kit
Rain shield
DIN rail installation set
The Vaisala HUMICAP® Humidity and
Temperature Transmitter HMT334
is designed to measure humidity
in pressurized spaces or vacuum
chambers. Each probe is tested
to ensure a gas and vacuum tight
installation.
41 (1.61)
120 (4.72)
170 (6.69)
Graphical display of
measurement trends and
real time history
Features/Benefits
▪
For temperatures
-70 ... +180 °C (-94 ... +356 °F)
The HMT330 series features a
numerical and graphical display. The
user can easily monitor operational
data, measurement trends and up to
one-year history.
▪
▪
Long metal probe head
▪
▪
Adjustable installation depth
The optional data logger with realtime clock makes it possible to
generate more than four years of
measured history, and zoom in on
any desired time or time frame.
Using a serial line, the measurement
data can be transferred to a PC where
it can be further processed and
copied to other programs.
The Vaisala HUMICAP® Humidity and
Temperature Transmitter HMT335 has
a long stainless steel probe designed
for high temperatures.
Robust probe ideal for
high flow rates
Stainless steel installation
flange available
Application example:
hot drying processes
The HMT335 is ideal for duct
measurements as the probe tolerates
mechanical stress and withstands high
flow rates. The HMT335 can be used,
for example, in a hot drying process.
Technical Data
Graphical display of history
and measurement trends
Temperature measurement range
-70 ... +180 °C (-94 ... +356 °F)
The HMT335 features a numerical and
graphical display. The user can easily
monitor measurement operational
data, measurement trends and oneyear measurement history.
The optional data logger with realtime clock makes it possible to
generate more than four years of
measured history, and zoom in on
any desired time or time frame.
Vaisala HUMICAP®
performance
The sensor provides accurate and
reliable measurement and is immune
to particulate contamination and
most chemicals.
Accessories
Mounting flange
PC software + cable
USB-RJ45 Serial Connection Cable
Connection cable for HM70
Wall mounting plate (plastic)
Pole installation kit
Rain shield
DIN rail installation set
Dimensions
Dimensions in mm (inches)
210696
215005
219685
211339
214829
215108
215109
215094
41 (1.6)
51 (2.0)
ø13.5 (0.53)
The HMT334 is ideal for permanent installations into pressurized or vacuum
processes.
192 (7.56)
253 (9.96)
17
HMT337 Humidity and Temperature Transmitter
for High Humidity Applications
HMT338 Humidity and Temperature Transmitter
for Pressurized Pipelines
down to the appropriate depth. The
hex nut is tightened with a wrench
to lock the probe in its place. Hot
tapping is possible in pressures up to
10 bar.
Graphical display of
history and measurement
trends
Duct installation kit
From the display, the user can
easily monitor operational data,
measurement trends and one-year
measurement history.
Features/Benefits
The HMT337 is the ideal transmitter for the most demanding process and
meteorological measurements.
Technical Data
Temperature measurement range
-70 ... +180 °C (-94 ... +356 °F)
Accessories
Cable gland and AGRO
HMP247CG
Duct installation kit (RH probe)
210697
Duct installation kit (T probe)
215003
Swagelok fittings (NPT and ISO)
for both RH and T probes
Solar radiation shield
DTR502B
Meteorological inst. kit
HMT330MIK
PC software + cable
215005
USB-RJ45 Serial Connection Cable 219685
Connection cable for HM70
211339
Wall mounting plate (plastic)
214829
Pole installation kit
215108
Rain shield
215109
DIN rail installation set
215094
Dimensions
▪
Warmed probe for superior
performance in condensing
environments
▪
Small, stainless steel, vaportight remote probe
▪
For temperatures
-70 ... +180 °C (-94 ... +356 °F)
The HMT338 is ideal for installations in pressurized processes where the probe
needs to be removed while the is running.
measurement in environments where
humidity is near saturation. The
warming prevents condensation from
forming on the sensor.
Features/Benefits
▪
r #BTJDOPOXBSNFEQSPCFGPS
moderate humidities
As the probe is warmed, the humidity
level inside it stays below the ambient
level. With accurate temperature
measurement, the ambient dewpoint
can be calculated precisely.
Installed through ball valve
– can be inserted and removed
while the process is running
▪
▪
▪
Adjustable probe depth
If the relative humidity value is
needed, an additional temperature
sensor is used. The measured
ambient temperature provides
the compensation for calculating
relative humidity and other humidity
parameters.
▪
Two probe lengths available
r 8JUIBXBSNFEQSPCFGPSOFBS
condensing conditions and dew
point measurement
r 8JUIBXBSNFEQSPCFBOEBO
additional temperature sensor: for
near-condensing conditions and
relative humidity measurement
True humidity readings
in conditions of
condensation
Many ways to install
The Vaisala unique warmed
probe provides fast and reliable
M9×1
37.5 (1.48)
79.5 (3.13)
99.5 (3.92)
18
For high-humidity applications
in industry and meteorology
The Vaisala HUMICAP® Humidity
and Temperature Transmitter
HMT337 is delivered in one of three
configurations:
ø 12 (0.47)
Dimensions in mm (inches)
▪
A tight installation through a process
wall can be achieved with Swagelok ®
fittings. Meteorological installation
kits for outdoor installations and duct
installation kits are also available.
Pressure tolerance 40 bar
For temperatures
-70 ... +180 °C (-94 ... +356 °F)
The Vaisala HUMICAP® Humidity and
Temperature Transmitter HMT338 is
designed for pressurized processes.
Insert or remove probe
while the process is
running
With “hot tapping”, the probe is
inserted directly into the process
while it is running, without the need
for venting or lowering the process
pressure.
The probe is screwed into a ball
valve assembly that has been fixed
to the process pipe or wall. The
adjustable hex nut is hand-tightened
to temporarily hold the probe to the
process. Then the probe is pushed
The optional data logger with
real-time clock makes it possible
to generate more than four years
of measured history, and zoom in
on any desired time or time frame.
The battery backup of the real-time
clock guarantees a reliable logging of
measured data.
Vaisala HUMICAP®
The HMT338 incorporates Vaisala’s
more than 30 years of experience in
industrial humidity measurement.
The sensor provides accurate and
reliable measurement and is immune
to particulate contamination and
most chemicals.
Technical Data
Temperature measurement range
-70 ... +180 °C (-94 ... +356 °F)
Operating pressure
0 ... 4MPa (0 ... 40 bar)
Accessories
Ball valve set
BALLVALVE-1
Pressure fitting ISO 1/2 to NPT 1/2 210662
PC software + cable
215005
USB-RJ45 Serial Connection Cable 219685
Connection cable for HM70
211339
Wall mounting plate (plastic)
214829
Pole installation kit
215108
Rain shield
215109
DIN rail installation set
215094
Dimensions
Dimensions in mm (inches)
19
HMT360 Series Intrinsically Safe Humidity and
Temperature Transmitters
Interchangeable Probes for HMT360 Intrinsically
Safe Humidity and Temperature Transmitter
The HMT360 offers six probe options
for various applications:
HMP361
HMP363
HMP364
HMP365
HMP367
HMP368
Features/Benefits
▪
▪
▪
▪
▪
Measures humidity and
temperature, outputs also
dewpoint, mixing ratio,
absolute humidity and wet
bulb temperature
Safe operation with the entire
transmitter in hazardous areas:
Division 1 and 2 (USA, Canada),
Categories 1G / Zone 0 and
1D / Zone 20 with protection
cover (EU)
Intrinsically safe
Designed for harsh conditions
Vaisala HUMICAP® Sensor
features high accuracy,
excellent long-term stability,
and negligible hysteresis
The Vaisala HUMICAP® Humidity
and Temperature Transmitter Series
HMT360 are the ideal solution for
measuring humidity in hazardous
areas. They operate safely and
reliably even in the most hazardous
classifications. The HMT360
transmitters' proven performance
and technology conform with
rigorous international standards.
Intrinsically safe
The entire HMT360 transmitter can
be installed directly in explosive
areas. It can withstand continuous
exposure to potentially explosive
environments that contain flammable
gases or dust.
▪
▪
Six probe options
Customized configuration
Temperature range between
-40 … +180°C (-40 … +356°F)
depending on the probe option
Due to the microprocessor based
electronics, options and accessories,
the HMT360 series is truly flexible.
▪
NIST traceable (certificate
included)
20
Temperature
range
-40 ... +60 °C
(-40 ... +140 °F)
Probe diameter
12 mm
41 (1.61)
86 (3.39)
127 (5)
The HMP361 probe in this picture has
a stainless steel netting filter.
- wall mount
- confined spaces
- pressurized spaces
- high temperature
- high humidity
- pressurized
pipelines
The interchangeable probes
enable fast and easy removal or
re-installation when required.
Calibration, for example, is easy
to perform due to the modular
structure. All calibration coefficients
are included in the probe unit itself,
which means that probes can be
switched between transmitter bodies
without losing the accuracy.
Dimensions in mm (inches)
Technical Data
Dimensions
HMP363 for confined spaces
Dimensions in mm (inches)
Temperature range with
The HMP363 probe is small and fits
into tight spaces.This one is connected
with a teflon cable.
teflon cable
-40 ... +120 °C
(-40 ... +248 °F)
rubber cable
-40 ... +80 °C
(-40 ... +176 °F)
Probe cable length
In addition to the standard Vaisala
HUMICAP® Sensor, an application
specific, very chemically durable
sensor is also available.
75 (2.96)
50 (1.97)
adjustable
Installation
Swagelok for 12mm
probe, 1/2" NPT
thread
Installation flange:
aluminum or
stainless steel
12 mm
flange
Ø12 (0.47)
Duct installation kit
Optimized sensors
Installation kit for
duct mounting
2, 5 or 10 meters
Probe diameter
Cable Gland M20x1.5
with splitting seal
37.5 (1.48)
98.5 (3.88)
210697
duct wall
HMP247CG
drilling 16...22 (0.63...0.87)
SWG12NPT12
Long-term solution
Technical Data
Dimensions
The HMT360 transmitters are an
investment; their rugged design,
combined with trouble-free
operation, ensure a long-term
solution for monitoring humidity and
dewpoint in explosive environments.
HMP364 for high pressure
Dimensions in mm (inches)
Customized calibration and
maintenance contracts for the
HMT360 series are available on
request.
Temperature range
Pressure range
Probe cable length
Probe diameter
The HMP364 probe is designed for
measurement in pressurized spaces or
vacuum chambers.
-40 ... +180 °C
(-40 ... +356 °F)
0 ... 10 MPa
(6.69)
2 (0.47)
The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT361 wall mount
transmitter, shown with six probe options, is designed specifically for hazardous and
explosive environments.
HMP361 for wall mounting
62 (2.44)
Interchangeable probes
Dimensions
ø12 (o.47)
Customers may specify the
transmitter configuration when
ordering the instrument, however
changes in configuration can also
easily be made in the field.
Technical Data
ø 12 (0.47)
www.vaisala.com
120 (4.72)
(0.55)
(1.14)
2, 5 or 10 meters
12 mm
Fitting body M22x1.5
17223
Fitting body NPT1/2
17225
21
Technical data
Temperature range
operating temp. range for
electronics
with display
storage
Pressure range
Dimensions
HMP365 for high temperature
Dimensions in mm (inches)
Measurement range
0 ... 100 %RH
Accuracy (including non-linearity, hysteresis, and repeatability)
with Vaisala HUMICAP® 180 or 180R
for typical applications
at +15 ... +25 °C (59 ... +77 °F)
± 1.0 %RH (0 ... 90 %RH)
-40 ... +180 °C
(-40 ... +356 °F)
41 (1.6)
2, 5 or 10 meters
Probe diameter
ø13.5 (0.53)
Technical Data
Probe cable length
51 (2.0)
192 (7.56)
13.5 mm
at -20 ... +40 °C (-4 ... +104 °F)
253 (9.96)
75 (2.96)
Installation
at -40 ... +180 °C (-40 ... +356 °F)
50 (1.97)
Mounting flange
210696
Cable Gland M20x1.5
with splitting seal
Installation flange:
stainless steel
HMP247CG
Dimensions
HMP367 for high humidities
Dimensions in mm (inches)
-40 ... +180 °C
(-40 ... +356 °F)
Probe cable length
2, 5 or 10 meters
Probe diameter
M9×1
Temperature range
ø 12 (0.47)
Technical Data
12 mm
37.5 (1.48)
Installation
79.5 (3.13)
Duct installation kit
210697
Cable Gland M20x1.5
with splitting seal
HMP247CG
Swagelok for 12mm
probe, 3/8" ISO thread
SWG12ISO38
Swagelok for 12mm
probe, 1/2" NPT thread
SWG12NPT12
±1.7 %RH (90 ... 100 %RH)
±(1.0 + 0.008 x reading)
%RH
± (1.5 +0.015 x reading)
%RH
with Vaisala HUMICAP® 180L2
drilling 16...22 (0.63...0.87)
The HMP367 probe is constructed to
be installed in environments with high
humidities.
Operating environment
RELATIVE HUMIDITY
Temperature range
The HMP365 probe is designed for high
temperature environments.
Performance
for application with demanding
chemical environment
at -10... +40 °C (14 ... +104 °F)
± (1.0 + 0.01 x reading) %RH
at -40 ... +180 °C (-40 ... +356 °F) ± (1.5 + 0.02 x reading) %RH
Factory calibration uncertainty (+20 °C) ± 0.6 %RH (0 ... 40 %RH)
± 1.0 %RH (40 ... 97 %RH)
(Defined as ±2 standard deviation limits. Small variations
possible, see also calibration certificate.)
Response time (90 %) at +20 °C (+68 °F) in still air
with grid filter
8 s / 17 s*
with grid + steel netting filter
20 s / 50 s*
with sintered filter
40 s / 60 s*
* with HUMICAP® 180R sensor
HMP368 for pressurized
pipelines
Dimensions in mm (inches)
Probe cable length
2, 5 or 10 meters
41 (1.61)
Ø13.5 (0.53)
Dimensions
0 ... 4 MPa
Mechanics
Connections
0.5
0.1
The HMP368 probe enables flexible
installation in pressurized pipelines.
13.5 mm/12 mm
Two probe lenghts available.
°C
0
-0.1
R ½ ISO 7/1 or NPT½"
-0.2
41 - 149/371 (1.61 - 5.87/14.6)*
14 (0.55)
194/416 (7.64/16.4)
Length for standard / optional probes
*freely user adjustable length
-0.3
-0.4
-0.5
-0.6
-0.7
-80
-60
-40
-20
0
20
40
60
80
100
120
140
160
180
Installation
Fitting body ISO1/2 solid structure
DRW212076SP
Fitting body NPT1/2 solid structure
Cable bushings
Conduit fitting
Housing material
Housing classification
Housing weight
screw terminals, 0.33...2.0 mm
2 wires (AWG 14-22)
For 7.5...12mm or 10...15mm cable
diameters (M20)
NPT 1/2" (M20)
G-AlSi10Mg (DIN 1725)
IP66 (NEMA 4X)
950 g
Options and accessories
0.4
0.3
0.2
232/454 (9.13/17.9)
Probe diameter
Operating voltage
12 ... 28 V
with serial port (service mode)
15 ... 28 V
Analog outputs
two-wire 4 ... 20 mA, one standard, one optional
Typical accuracy of analog outputs at +20 °C
±0.05% full scale
Typical temperature dependence
of analog outputs
0.005% / °C (0.005% / °F) full scale
Analog outputs
connection via safety barriers
RS232C serial output for service use
connector type RJ45
Display
two-line LCD
Measurement range
-40 ... +180 °C (-40 ... +356 °F)
(depends on selected probe)
Typical accuracy of electronics at +20 °C (+68 °F) ±0.2 °C (0.36 °F)
Typical temparature dependence
of electronics
0.005 °C/°C (0.005 °F/°F)
Sensor
Pt 1000 RTD 1/3 Class B IEC 751
Accuracy over temperature range
Technical Data
Pressure range
Inputs and outputs
TEMPERATURE
°C
0.7
-40 ... +180 °C
(-40 ... +356 °F)
Complies with EMC standard EN61326-1, Electrical equipment for
measurement, control and laboratory use - EMC requirements;
Industrial Environment.
NOTE! IEC 1000-4-5 complies only when using external EXi
approved surge arrester in the safe area.
99.5 (3.92)
0.6
Temperature range
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-4 ... +140 °F)
-40 ... +70 °C (-40 ... +158 °F)
see probe specifications
OTHER VARIABLES
Optionally available
dewpoint temperature, mixing ratio,
absolute humidity, wet bulb temperature.
Duct installation kit (for HMP363/367)
210697
Mounting flange (for HMP365)
210696
Ball valve ISO 1/2 with welding joint
BALLVALVE-1
(for HMP368)
pressure range at +20 °C (+68 °F):
0 ... 20 bar (0 ... 290 psia)
(during installation max. 10 bar (145 psia)
Calibration adapter for HMK15
211302
Serial interface cable for PC
connectors RJ45 - D9 female
25905ZZ
Galvanic isolator
212483
Zener barrier (USA & Canada)
210664
Protection cover (for use in the
214101
presence of combustible dust, ATEX)
II 1 D IP65 T = 70 °C
NPTFITBODASP
Ball valve ISO 1/2 with welding joint
BALLVALVE-1
22
23
Classification with current outputs
Dimensions
EUROPE / VTT
Dimensions in mm (inches)
Safety factors
II 1 G
Ex ia IIC T4 Ga
VTT 09 ATEX 028 X issue No: 1
Ui = 28 V, Ii = 100 mA, Pi = 700 mW
Ci = 1 nF, Li negligibly low
Environmental specifications
Tamb
-40 ... +60 °C (-40 ... +140 °F)
0.8 ... 1.1 bar
Pamb
Dust classification (with protection cover) II 1 D (IP65 T=70 °C)
VTT 04 ATEX 023X
USA (FM)
Classes I, II, III, Division 1, Groups A-G and
Division 2, Groups A-D, F and G
FM Project ID: 3010615
Safety factors:
Vmax = 28 VDC, Imax = 100 mA,
Ci = 1 nF, Li = 0, Pi = 0.7 W, Tamb= 60 °C(140 °F), T5
JAPAN (TIIS)
Ex ia IIC T4
Code number: TC17897
Safety factors:
Ui = 28 VDC, Ii = 100 mA, Ci = 1 nF,
Pi = 0.7 W, Li = 0, Tamb= 60 °C (140 °F)
39 (1.5)
115 (4.53)
EU (94/9/EC, ATEX100a)
Accessories
164 (6.46)
125 (4.92)
HMT361
73 (2.9)
11 (0.43) 62 (2.4)
Accessory
Ball valve ISO 1/2 with welding joint
Cable Gland M20 x 1.5 with splitting seal
Duct installation kit
Fitting body ISO1/2 solid structure
Fitting body M22 x 1.5
Fitting body NPT1/2
Fitting body NPT1/2 solid structure
Mounting flange
Swagelok for 12mm probe, 1/2" NPT thread
Swagelok for 12mm probe, 3/8" ISO thread
part number
BALLVALVE-1
HMP247CG
210697
DRW212076SP
17223
17225
NPTFITBODASP
210696
SWG12NPT12
SWG12ISO38
HMT363
HMT364
HMT365
HMT367
√
√
√
HMT368
√
√
√
√
√
√
√
√
√
√
√
√
CANADA (CSA)
Class I
Class II
Division 1 and Division 2, Groups A, B, C, D;
Division 1 and Division 2, Groups G and
Coal Dust;
Class III
CSA File No: 213862 0 000, CSA Report: 1300863
Safety factors:
Tamb= 60 °C, T4,
Intrinsically safe when connected as per
Installation Drawing DRW213478.
CHINA (PCEC)
Ex ia II CT4
Certificate No. CE092145
Standard GB3836.1-2000 and GB3836.4-2000
IECEx (VTT)
Ex ia IIC T4 Ga
IECEx VTT 09.0002x issue No: 1
Safety factors
Ui = 28 V, Ii = 100 mA, Pi = 700 mW
Ci = 1 nF, Li negligibly low
Environmental specification
-40 ... +60 °C (-40 ... +140 °F)
Tamb
Pamb
0.8 ... 1.1 bar
For more information, visit
www.vaisala.com or contact
us at [email protected]
24
Ref. B210956EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
25
www.vaisala.com
HMT310 Humidity and Temperature
Transmitter
Technical data
Measured values
Electrical connections
RELATIVE HUMIDITY
typical applications
applications with chemical
purge and/or warmed probe
Accuracy (incl. non-linearity, hysteresis and repeatability)
at a temperature range of
+15 ... +25 °C
±1 %RH (0 ... 90 %RH)
±1.7 %RH (90 ... 100 %RH)
-20 ... +40 °C
±(1.0 + 0.008 x reading) %RH
-40 ... +180 °C
±(1.5 + 0.015 x reading) %RH
Factory calibration uncertainty
±0.6 %RH (0 ... 40 %RH)*
(+20 °C)
±1.0 %RH (40 ... 97 %RH)*
Two analog outputs,
0 ... 20 mA or 4 ... 20 mA
selectable and scalable
Typical accuracy of analog output at +20 °C
+0.05 % full scale
Typical temperature dependence
0.005 %/°C (0.003 %/°F)
of analog output
of full scale
Serial output
RS--232C
Connections
M12 8-pole connector with RS-232C,
current outputs (two channels) and Uin
Operating voltage
12 ... 35 VDC, the maximum
operating voltage for a device with
sensor heating is 24 VDC
Power consumption
30 mA with RS-232
External load
Rl < 500 Ohm
Startup time after powerup
3s
* Defined as ±2 standard deviation limits. Small variations possible, see
also calibration certificate.
General
Measurement range
Sensor
Vaisala HUMICAP®180R
Vaisala HUMICAP®180RC
0 ... 100 %RH
Response time (90 %) at +20 °C
17 s with grid filter
in 0.1 m/s air flow
50 s with grid and steel, netting filter
60 s with sintered filter
TEMPERATURE
HMT311
HMT313
-40 ... +60 °C (-40 ... +140 °F)
-40 ... +80 °C (-40 ... +176 °F)
or -40 ... +120 °C (-40 ... +248 °F)
HMT314, HMT315, HMT317, HMT318 -70 ... +180 °C (-94 ... +356 °F)
The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT310 models
(from left to right): HMT313, HMT317, HMT314, HMT318, HMT315 and HMT311.
Accuracy over temperature range (see graph below)
Features/Benefits
▪
▪
Next-generation Vaisala
HUMICAP® Sensor for excellent
accuracy and stability
Full 0 ... 100 %RH
measurement, temperature
range up to +180 °C
(depending on model)
▪
▪
Small size, easy to integrate
▪
NIST traceable
Insensitive to dust and most
chemicals
Reliable Vaisala
HUMICAP® technology
The HMT310 incorporates the latestgeneration Vaisala HUMICAP® Sensor.
The Vaisala HUMICAP® Sensor is a
capacitive thin-film polymer sensor.
It features high accuracy, excellent
long-term stability and negligible
hysteresis. It is insensitive to dust,
particulate dirt and most chemicals.
Several outputs, one
connector
The HMT310 is powered up with
12 ... 35 VDC. It has two analog
outputs and an RS-232 serial output.
The output signal and the supply
power travel in the same cable, the
only cable connected to the unit.
26
Chemical purge
Chemical purge helps to maintain
measurement accuracy between
calibraton intervals and it involves
heating the sensor to remove harmful
chemicals. The function can be
initiated manually or programmed to
occur at set intervals.
Δ °C
0.7
0.6
0.5
0.4
0.3
0.2
0.1
°C
0
-0.1
-0.2
-0.3
-0.4
-0.5
Optional functions
The following optional functions are
available: several probes for various
applications, calculated humidity
quantities, different mounting kits,
sensor protection options and probe
cable lengths, warmed probe and
sensor heating for high humidity
conditions (HMT317), and chemical
purge for applications risking an
interference with chemicals in the
measuring environment.
Operating temperature range for
electronics
-40 ... +60 °C (-40 ... +140 °F)
Storage temperature range
-55 .... +80 °C (-67 ... +176 °C)
Operating pressure
HMT314
0 ... 100 bar
HMT318
0 ... 40 bar
HMT315, HMT317
vapor tight
Transmitter housing material
G-AlSi10Mg
Transmitter base material
ABS/PC
Housing classification
IP65
Cable feed through
8-pole connector with 5 m cable,
alternatives
Female 8-pin connector screw joint for
cable diameter 4 ... 8 mm
Sensor protection
PPS grid with stainless steel net,
PPS grid, Sintered filter
Membrane stainless steel filter
Complies with EMC standard EN61326-1, Industrial environment
-0.6
-0.7
-80
-60
-40
-20
0
Typical temperature
dependence of electronics
Temperature sensor
20
40
60
80
100
120
140
160
180
Note: When using the current output, the RF field susceptibility
level according to standard EN61000-4-3 with a frequency band
of 110 ... 165 MHz, is only 3V/m (generic environment) with the
specified accuracy.
+0.05 °C/°C (+0.005 °F/°F)
Pt100 IEC751/3 class B
For more information, visit
www.vaisala.com or contact
us at [email protected]
HUMICAP® is a registered trademark of Vaisala.
Ref. B210769EN-C ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
27
www.vaisala.com
HMT100 Series Humidity and Temperature
Transmitter for Demanding HVAC Applications
Technical data
Performance
Inputs and outputs
RELATIVE HUMIDITY
Two-wire output signal
External loop load
Measurement range
0 ... 100 %RH
Accuracy against factory standards including non-linearity,
hysteresis, and repeatability
at +15 ... +25 °C (+59 ... +77 °F)
±1.7 %RH (0 ... 90 %RH)
±2.5 %RH (90 ... 100 %RH)
at ±0 °C ... +40 °C (+32 ... +104 °F)
±(1.7 +0.015 x reading) %RH
at -40 ... ±0 °C, +40 ... +80 °C
±(2.0+0.025 x reading) %RH
(-40 ... +32 °F, +104 ... +176 °F)
Factory calibration uncertainty
±1.0 %RH (0 ... 15 %RH)
at +20 °C (+68 °F)
±1.5 %RH (>15 ... 78 %RH)
Response time (90 %) at 20 °C in
8 s with plastic grid
still air
20 s with membrane filter
40 s with sintered filter
Humidity sensor
Vaisala HUMICAP® 180
TEMPERATURE
Measurement range
Accuracy at +20 °C (+68 °F)
-40 ... +80 °C (-40 ... 176 °F)
±0.2 °C (±0.36 °F)
ACCURACY OVER TEMPERATURE RANGE
HMT100 remote probe and wall mount models.
Features/Benefits
▪
▪
▪
Full 0 ... 100 %RH measurement
Two-wire loop-powered or
three-wire voltage output
configurations
Fixed and remote probe
models
The Vaisala HUMICAP® Humidity
and Temperature Transmitter Series
HMT100 are designed for humidity
and temperature monitoring in
demanding environments.
Typical applications include stability
rooms, HVAC, livestock farms,
greenhouses, indoor swimming
pools, and outdoor applications.
▪
▪
Display available
▪
▪
Vaisala HUMICAP® sensor
▪
▪
Different output scalings
Available options
Compatible with hand-helds
HM70 and HMI41 for calibration
▪
▪
IP65 (NEMA 4) housing
The HMT100 is available as a wall
mount or remote probe model with
an optional display. For high
temperature applications or where
space is limited, the remote probe is
ideal.
28
Relative humidity, dewpoint,
temperature outputs
Interchangeable probe module
for minimal maintenance
downtime
NIST traceable (certificate
included)
Performance
HMT100 incorporates Vaisala
HUMICAP® technology that measures
relative humidity accurately and
reliably. Vaisala HUMICAP® is also
resistant to dust and most chemicals.
HMT100 can show relative humidity
only, dewpoint only, or relative
humidity and temperature, or
dewpoint and temperature readings.
The probes are interchangeable
without having to calibrate or adjust
the transmitter.
HMT100 can also be installed
outdoors using an installation kit,
or directly into an air conditioning
channel using a duct installation kit.
Annual calibration
Calibration is recommended typically
at an interval of one year using either
the Vaisala HUMICAP® Hand-held
Humidity and Temperature Meter
HM70 or the Vaisala HUMICAP®
Humidity Indicator HMI41.
The accuracy of the instrument can
also be checked using the Vaisala
Humidity Calibrator HMK15, which is
based on saturated salt solutions.
4 ... 20 mA
10 ... 35 VDC (RL = 0 ohms)
20 ... 35 VDC (RL = 500 ohms)
Voltage output signals
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
(0 ... X V see order form)
Supply voltage
10 ... 35 VDC/24 VAC
Current consumption, 35 VDC/24 VAC
max. 12 mA
External load
RL min. 10 kΩ
Mechanics
Material
Housing
ABS/PC plastic
Probe
chrome coated aluminum
Mounting plate GM45160
ABS plastic
Housing classification
IP65 (NEMA 4)
Sensor protection
Plastic grid
DRW010522
Plastic grid with membrane filter
DRW010525
Sintered stainless steel filter
HM46670SP
Connections
screw terminals 0.5 ... 1.5 mm2
Probe cable lengths
3 m, 5 m, 10 m
Calibration
with HM70, HMI41,
or with internal 11 %RH & 75 %RH buttons
Display option
One line fixed variable or changing variables when two variables
are ordered
Options and accessories
Temperature sensor
Pt1000 IEC 751 1/3 class B
DEWPOINT TEMPERATURE (CALCULATED)
Measuring range
-20 ... +80 °C (-4 ... +176 °F)
Operating Environment
Operating temperature range
transmitter body, no display
transmitter body, with display
probe (remote probe only)
Storage temperature range
Electromagnetic
compatibility
-40 ... +60 °C (-40 ... +140 °F)
-30 ... +60 °C (-22 ... +140 °F)
-40 ... +80 °C (-40 ... +176 °F)
-40 ... +60 °C (-40 ... +140 °F)
EN61326-1,
Industrial Environment
For more information, visit
www.vaisala.com or contact
us at [email protected]
Spare probe
Spare extension cable (10 m)
Radiation shield
Rain shield with installation kit
Installation plate
Duct installation kit
Connection cable for HMI41
Connection cable for HM70
HMP100
DRW220095
DTR502B
215109
DRW010699
215619
2591722
211339
Ref. B210472EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
29
DMW19 Wall Mount Dewpoint Transmitters for
Indoor Applications
Technical data
Dewpoint temperature
Operating environment
'HZSRLQWWHPSHUDWXUHƒ&
Measurement range
Accuracy
The Vaisala HUMICAP® Hand-Held
Humidity and Temperature Meter HM70
is an easy and fast way to confirm the
performance of DMW19 on site.
Vaisala HUMICAP® Dewpoint Transmitter DMW19 is a compact wall mount
dewpoint transmitter.
Features/Benefits
▪
Designed for demanding
building automation
applications and other wall
mount indoor applications
where dewpoint measurement
is needed
▪
Dewpoint measurement range
-20 ... +55 °C (-4...+131 °F)
▪
▪
Accuracy ±2 °C (±3.6 °F)
▪
30
Vaisala HUMICAP® Sensor
for excellent accuracy and
long-term stability, negligible
hysteresis and resistance to
dust and most chemicals.
Electronic, on site, one-point
field check with Vaisala
HUMICAP® Hand-Held
Humidity and Temperature
Meter HM70
The wall mount Vaisala HUMICAP®
Dewpoint Transmitter DMW19 is
designed for use in air conditioning
and other indoor wall mount
applications where accurate and
stable dewpoint measurement is
required. DMW19 is an ideal choice
for demanding building automation
applications where dewpoint is the
preferred parameter for humidity
measurement.
Proven Vaisala HUMICAP®
Sensor Technology
The operation of DMW19 is based on
the proven Vaisala HUMICAP® Sensor.
The dewpoint is calculated from
relative humidity and temperature.
The patented Vaisala HUMICAP®
Sensor is insensitive to dust,
particulate dirt and most chemicals.
This results in high accuracy,
excellent long-term stability and
negligible hysteresis.
-20 ... +55 °C (-4 ... +131 °F)
±2 °C (±3.6 °F) (see graph below)
5LVNRIFRQGHQVDWLRQ
Operating temperature
Storage temperature
Relative humidity
-5 ... +60 °C (+23 ... +140 °F)
-40 ... +80 °C (-40 ... 176 °F)
0 ... 95 %RH
operating and storage
Electromagnetic compatibility
Complies with EMC standard EN61326-1, Generic Environment
$FFXUDF\“ƒ&7G
Dimensions
Dimensions in mm
$FFXUDF\QRWVSHFLILHG
3URFHVVWHPSHUDWXUHƒ&
Dewpoint accuracy vs. measurement conditions
Response time
15 s
Humidity sensor
Vaisala HUMICAP® 180
Temperature sensor
Pt 100 IEC 751 1/3 class B
33 (1.30)
85 (3.35)
Operating environment
Operating temperature
Storage temperature
Relative humidity
-5 ... +60 °C (+23 ... +140 °F)
-40 ... +80 °C (-40 ... 176 °F)
0 ... 95 %RH
operating and storage
1 1 0 ( 4 .3 3 )
www.vaisala.com
Outputs
Analog outputs (scalable)
Easy to install
DMW19 is compact and lightweight.
In addition, DMW19 is easy to install
and it is suitable for different junction
boxes.
Fast, on-site field check
The accuracy of the transmitter
is simple to check on-site using
the Vaisala HUMICAP® Hand-Held
Humidity and Temperature Meter
HM70.
DMW19 is suitable for demanding
building automation and other wall
mount indoor dewpoint measurements.
Resolution for current output
Resolution for voltage output
Typical temperature dependence
4 ... 20 mA
0 ... 1 V
0 ... 5 V
0.002 mA
0.3 mV
0.005 % of span/ °C
General
Operating voltage with voltage output
12 ... 35 VDC
11 ... 28 VAC
Operating voltage with current output
20 ... 35 VDC / 19 ... 28 VAC with RL500 ohm
17 ... 35 VDC / 16 ... 28 VAC with RL50 ohm
Supply current
10 mA + load current
Load for voltage output
min. 10 kohm
Load for current output
max. 500 ohm
Connections
screw terminals 0.5 ... 1.5 mm2
Housing
ABS plastics
Housing colour
NCS-2502-R
Housing classification
IP33
Weight
110 g
For more information, visit
www.vaisala.com or contact
us at [email protected]
HUMICAP® is a registered trademark of Vaisala.
Ref. B210394EN-B ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
31
www.vaisala.com
HMD60/70 Humidity and Temperature
Transmitters for ducts in HVAC applications
Features/Benefits
▪
▪
▪
▪
▪
®
Vaisala HUMICAP Humidity and Temperature Transmitters HMD60 and HMD70 are
designed for use in air conditioning applications where accurate and stable control
of relative humidity and temperature are required.
The duct mounted Vaisala HUMICAP®
Humidity and Temperature
Transmitters HMD60 and HMD70
are designed for monitoring relative
humidity and temperature in building
energy management systems.
The combination of high accuracy,
stability and reliable operation, make
these products the ideal choice for
demanding applications.
Measures both humidity
and temperature
Resistant to chemicals
and dust
The accuracy of the transmitters
is simple to check using either
the Vaisala HUMICAP® Hand-Held
Humidity and Temperature Meter
HM70 or the Vaisala HUMICAP®
Humidity Indicator HMI41. The
calibration can be done in seconds
with a single potentiometer without
disturbing the operation, resulting
in great savings both in maintenance
time and costs.
The duct mount HMD60 and HMD70
transmitters can also be used in
many industrial humidity monitoring
applications, where their stability
and resistance to chemicals and dust
are of great value. A useful feature
of these duct mount transmitters is
the ability to remove the electronics
without removing the unit from
the duct.
32
The HMD60 and HMD70 transmitters
are available in three models:
U for humidity measurement-only,
Y for humidity and temperature
measurement, and T for temperature
only.
▪
▪
▪
▪
Full 0 ... 100 %RH measurement
Technical data
60 series: 2-wire, 4 to 20 mA output
Duct mount
Selectable signal output of
0 ... 1 V, 0 ... 5 V or 0 ... 10 V
(HMD70) with optional current
module also 0 ... 20 mA
(HMD70)
Vaisala HUMICAP® Sensor
for excellent accuracy and
long-term stability, negligible
hysteresis and resistance to
dust and most chemicals.
Output signal
Supply voltage range depends on the selected output signal
DC
AC
0 ... 1V
10 ... 35 V
9 ... 24 V
0 ... 5 V
14 ... 35 V
12 ... 24 V
0 ... 10 V
19 ... 35 V
16 ... 24 V
RH only
RH & T
T only
HMD70U
HMD70Y
HMD70T
Relative humidity
Measurement range
duct mount
Accuracy at +20 °C
0 ... 100 %RH*
%RH
3
2
1
0
-1
0
10
20
30
40
50
60
70
80
90
WITH OPTIONAL CURRENT MODULE
0 ... 20 mA (RL = 0 ohm)
10 ... 35 V
**0 ... 20 mA (RL = 500 ohm) 20 ... 35 V
Power consumption @ 24 VAC
HMD70U
HMD70Y
11 ... 24 V
17 ... 24 V
10 mA typical
12 mA typical
100 %RH
General
-2
-3
Temperature dependence
%RH
2.0
-20 °C, + 1,5 %
1.5
1.0
0.5
0
-20
-10 0
10
-0.5
+80 °C, + 1,3 %
20
30
40
50
60
70
80
°C
-1.0
-1.5
-2.0
Response time at +20 °C (+68 °F),
90% response
Stability
Sensor
15 s (with membrane filter)
+ 2 %RH / 2 years
HUMICAP® 180
Temperature (Y and T models)
Linearity
Sensor
Measurement range
Accuracy
better than 0.1 °C
Pt 1000 IEC 751 class B
-20 ... +80 °C (-4 ... 176 °F) **
Operating temperature range
electronics
-5 ... +55 °C (+23 ... +131 °F)
probe
-20 ... +80 °C (-4 ... +176 °F)
Storage temperature range
-40 ... +80 °C (-40 ... +176 °F)
Maximum flow speed
50 m/s
Current module
part no. 18945 HM
Housing
probe
stainless steel
electronics
cast aluminum
Connections
screw terminals 0.5 ... 1.5 mm2
Sensor protection
standard
membrane filter (part no. DRW010525)
optional
stainless steel sintered filter (part no. HM46670SP)
Cable thread-through
bushing for 7 ... 10 mm (PG9)
cable housing IP65 (NEMA 4)
part no. 18941HM
armoured cable glands
part no. 10528HM
(must be ordered separately)
0.8
Complies with EMC standard EN61326 and EN55022
0.6
Fast, on-site calibration
10 ... 35 VDC (RL = 0 ohm)
20 ... 35 VDC (RL = 500 ohm)
4 ... 20 mA
General - 70 series
IP65 (NEMA 4) housing
NIST traceable
(certificate included)
Supply voltage
Duct mount
Temperature compensated
Also available as temperatureonly transmitters
HMD 60T/70T
HMD60U
HMD60Y
HMD60T
70 series: 3-wire, variable voltage output
Accuracy up to ±2 %RH
True two-wire transmitters
with 4 ... 20 mA loop powered
output (HMD60)
General - 60 series
RH only
RH & T
T only
0.4
0.2
0
-20
-10
0
10
20
30
40
50
60
70
80 -0.2
-0.4
-0.6
-0.8
** Optional temperature scales are available on request.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210839EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
33
www.vaisala.com
HMW60/70 Humidity and Temperature
Transmitters for wall mounting in HVAC applications
Technical data
60 series: 2-wire, 4 to 20 mA output
Wall mount
General - 60 series
RH only
RH & T
T only
HMW60U
HMW60Y
HMW60T
Supply voltage
10 ... 35 VDC (RL = 0 ohm)
20 ... 35 VDC (RL = 500 ohm)
4 ... 20 mA
Output signal
70 series: 3-wire, variable voltage output
General - 70 series
Wall mount
Supply voltage range depends on the selected output signal
DC
AC
0 ... 1V
10 ... 35 V
9 ... 24 V
0 ... 5 V
14 ... 35 V
12 ... 24 V
0 ... 10 V
19 ... 35 V
16 ... 24 V
Power consumption @ 24 VAC
HMW70U
10 mA typical
HMW70Y
12 mA typical
RH only
RH & T
T only
HMW70U
HMW70Y
HMW70T
Relative humidity
Measurement range
Accuracy at +20 °C
0 ... 95 %RH*
%RH
3
2
General
1
0
0
-1
10
20
30
40
50
60
70
80
90
100 %RH
-2
-3
Temperature dependence
%RH
+55, + 0,5 %
-5 °C, + 1 %
1.0
0.5
0
®
Vaisala HUMICAP Humidity and Temperature Transmitters HMW60 and HMW70 are
designed for use in air conditioning applications where accurate and stable control
of relative humidity and temperature are required.
Features/Benefits
▪
▪
Accuracy up to ±2 %RH
▪
Selectable signal output of
0 ... 1 V, 0 ... 5 V or 0 ... 10 V
(HMW70)
▪
▪
▪
▪
34
True two-wire transmitters
with 4 ... 20 mA loop powered
output (HMW60)
Vaisala HUMICAP® Sensor
for excellent accuracy and
long-term stability, negligible
hysteresis and resistance to
dust and most chemicals.
Temperature compensated
Also available as temperatureonly transmitters
HMW 60T/70T
NIST traceable
(certificate included)
The wall mounted Vaisala HUMICAP®
Humidity and Temperature
Transmitters HMW60 and HMW70
are designed for monitoring relative
humidity and temperature in building
energy management systems.
The combination of high accuracy,
stability and reliable operation, make
these products the ideal choice for
demanding applications.
Measures both humidity
and temperature
The HMW60 and HMW70 transmitters
are available in three models:
U for humidity measurement-only,
-10
0
10
20
30
40
50
60 °C
-0.5
-1.0
Y for humidity and temperature
measurement, and T for temperature
only.
Fast, on-site calibration
The accuracy of the transmitters
is simple to check using either
the Vaisala HUMICAP® Hand-Held
Humidity and Temperature Meter
HM70 or the Vaisala HUMICAP®
Humidity Indicator HMI41. The
calibration can be done in seconds
with a single potentiometer without
disturbing the operation, resulting
in great savings both in maintenance
time and costs.
Response time at +20 °C (+68 °F), 90 % response
15 s
Stability
+2 %RH / 2 years
Sensor
HUMICAP® 180
* Output signal corresponds to 0 ... 100 %RH
Operating temperature range
electronics
Storage temperature range
Long-term humidity range for
electronics
Housing
material
IP Class 30
Fire resistance
Colour
Connections
-5 ... +55 °C (+23 ... +131 °F)
-40 ... +80 °C (-40 ... +176 °F)
0 ... 85 %RH
ABS plastic
UL94-HB
NCS-2502-R
screw terminals 0.5 ... 1.5 mm2
Complies with EMC standard EN61326 and EN55022
Temperature (Y and T models)
Linearity
Sensor
Measurement range
Accuracy'
better than 0.1 °C
Pt 1000 IEC 751 class B
-5 ... +55 °C (+23 ... 131 °F) **
0.5
0.4
0.3
0.2
0.1
0
-10
0
10
20
30
40
50
60 -0.1
-0.2
-0.3
-0.4
-0.5
** Optional temperature scales are available on request.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210840EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
35
www.vaisala.com
HMW40/50 and HMD40/50 Wall and
Duct Mount Transmitters for HVAC Applications
Technical data
Relative humidity
Measurement range
(for which accuracy is specified)
Operating range
HMD40/50
HMW40/50
Accuracy at +20 °C (+68 °F)
Stability
Temperature dependence
Sensor
10 ... 90 %RH
0 ... 100 %RH
0 ... 90 %RH
better than ±3 %RH
±2 %RH over 2 years
<±1.5 %RH from -10 ... +60 °C
(+14 ... 140 °F)
INTERCAP® Sensor, part no. 15778HM
Temperature (40Y and 50Y)
In energy management systems, the
accurate measurement of relative
humidity and temperature is essential
for optimum control of the environment.
Vaisala INTERCAP ® Humidity and Temperatur e Transmtters HMD/W40/50 are
competitively priced and require no routine maintenance – a smart choice for your
HVAC/EMC applications.
Features/Benefits
▪
Specially designed for building
energy management systems
▪
▪
10 ... 90 %RH measurement
▪
-5 ... +55 °C (+23 ... +131 °F)
operating range for wall units
▪
4 ... 20 mA 2-wire output
(HMD/W40)
▪
Selectable voltage 3-wire
output (HMD/W50)
▪
Combines excellent stability
with easy installation and
reliable operation
▪
▪
No recalibration
▪
Low cost
36
-10 ... +60 °C (+14 ... +140 °F)
operating range for duct units
Fully interchangeable Vaisala
INTERCAP® Sensor is easy to
replace
The two and three-wire Vaisala
INTERCAP® Humidity and
Temperature Transmitters HMD/W40
and HMD/W50 are designed for use
in energy management systems in
buildings. They combine excellent
stability with easy installation and
reliable operation. The HMD40/50
are for duct installations and the
HMW40/50 for wall installations.
Low maintenance costs
The HMD40/50 humidity transmitters
use Vaisala INTERCAP® Sensor the world’s first interchangeable
capacitive humidity sensor. The
transmitters require no recalibration
if the sensor is changed. This means
great savings in overall maintenance
costs. The sensor is also insensitive
to dust as well as most chemicals.
Measures both humidity
and temperature
The 40/50 series is available as
humidity and temperature (Y), or
humidity only (U) transmitters. The
transmitters measure humidity with
a ±3 %RH accuracy and a ±1 %RH
stability per year.
Measurement range
HMD40/50
HMW40/50
Total accuracy at +25 °C
Temperature dependence
Sensor
-10 ... +60 °C (+14 ... +140 °F)
-5 ... +55 °C (+23 ... +131 °F)
±0.3 °C (±0.54 °F)
0.01 °C/°C (0.01 °F/°F)
Pt 1000 IEC 751 class B
Power supply
HMD/W40
HMD/W50
10 ... 28 VDC
for 0 ... 1 V output: 12 ... 35 VDC/12 ... 24 VAC
for 0 ... 10 V output: 15 ... 35 VDC/15 ... 24 VAC
Electromagnetic compatibility:
Complies with EN61326-1,
Generic Environment
Current consumption
HMD/W50
6 mA typical
Operating temperature range
HMD40/50
-10 ... +60 °C (+14 ... +140 °F)
HMW40/50
-5 ... +55 °C (+23 ... +131 °F)
Storage temperature range
-40 ... +60 °C (-40 ... +140 °F)
Operating humidity range
HMD40/50
0 ... 100 %RH
HMW40/50
0 ... 90 %RH
Housing
Material
ABS plastic
Classification (HMD40/50)
IP65(NEMA 4)
Colour(HMW40/50)
NCS0502-G50Y
General
Dimensions
Output signal for relative humidity (equals 0...100 %RH)
HMD/W40
4 ... 20 mA
HMD/W50
0 ... 1 V & 0 ... 10 V
Output signal for temperature
HMD/W40
4 ... 20 mA
HMW50
0 ... 1 V & 0 ... 10 V
HMD50
0 ... 10 V
HMD40Y, HMD50Y
equals -40 ... +60 °C (-40 ... 140 °F)
HMW40Y, HMW50Y
equals -5 ... +55 °C (+23 ... 131 °F)
Dimensions in mm.
HMW40/50
HMD40/50
Selectable functions
(HMD/W50)
The HMD/W50 transmitters feature
selectable output signals of 0 to 1 V
and 0 to 10 V. They can be powered
by either AC or DC voltage.
INTERCAP® is a registered trademark of Vaisala
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210945EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
37
www.vaisala.com
HMM210 Series Humidity Modules
for Environmental Chambers
relative humidity and temperature or
dewpoint measurement with various
configurations. All modules have
microprocessor based electronics
and are equipped with analog or
digital outputs.
Unique warmed probe
The warmed probe and composite
sensor, available on the dewpoint
probe configuration, is warmed to
always remain a few degrees higher
than ambient. Advantages of this
patented technique include:
r /PDPOEFOTBUJPOQSPCMFNTPOUIF
probe, as the temperature of the
probe always remains higher than
the ambient.
Vaisala HUMICAP® Humidity and Temperature Module Series HMM210
provide fast real-time measurement in a wide temperature range.The
modules are especially suitable for demanding OEM applications,
e.g. environmental chambers and incubators.
Features/Benefits
▪
▪
Three probe configurations:
▪
Dewpoint probe with probe
heating. By heating the whole
probe a few degrees above
ambient condensation is
avoided.
Relative humidity (RH) plus
temperature (T) probe.
▪
Dewpoint probe described
above, together with a
temperature probe for
obtaining relative humidity and
temperature outputs.
▪
▪
Three module configurations
▪
Chemical purge option
maintains high measurement
performance in demanding
chemicalconditions.
▪
Calibration certificate included
38
Different probe and cable
lengths
The Vaisala HUMICAP® Humidity
and Temperature Module Series
HMM210 are designed for OEM type
applications needing humidity or
dewpoint measurement in demanding
environments, e.g. in environmental
chambers growth chambers and
incubators.
Demanding applications
The HMM210 modules are optimized
for harsh environments with
both high humidities and a wide
temperature range. The humidity
measurement is fully temperature
compensated. In addition, the
modules remain accurate and reliable
under extreme conditions where a
combination of high humidity and
rapidly changing temperature can
result in condensation on the sensor
head.
The modules are highly versatile
and flexible. They provide either
r 'BTUSFTQPOTFUJNFFTQFDJBMMZJO
rapidly changing temperatures.
r *NQSPWFETUBCJMJUZBOEBDDVSBDZJO
high humidities.
Vaisala HUMICAP® Sensor
and chemical purge
option
The HMM210 modules use
Vaisala HUMICAP®180R sensors
for best possible stability. The
sensor is insensitive to dust and
to most chemicals. In conditions
of extraordinary high levels of
chemicals and cleaning agents,
chemical purge is available as
an option. With chemical purge,
contaminants are evaporated from
the sensor and performance is
returned to normal.
Technical data
Relative Humidity
General
Measurement range
Accuracy (including non-linearity,
hysteresis and repeatability)
0 ... 100 %RH
+2 %RH (0 ... 90 %RH)
+3 %RH (90 ... 100 %RH)
Response time (90 % at +20 °C/+68 °F)
in still air (with sintered filter)
60 s
Typical temperature dependence
of electronics
0.02 %RH/°C (0.02 %RH/°F)
Humidity sensor
HUMICAP®180R
Temperature
Measurement range
-70 ... +180 °C (-94 ... +356 °F)
+0.1 °C (+0.18 °F)
Typical accuracy of electronics at +20 °C
Typical temperature dependence of electronics
0.0025°C/°C
(0.0025 °F/°F)
Temperature sensor in RH+T probe:
HMM211 and HMM213
Pt 100 RTD
IEC 751 1/3 Class B
HMM212
Pt 1000 RTD
IEC 751 1/3 Class B
Additional temperature probe
Pt 100 RTD
IEC 751 1/4 Class B
Outputs
Two analog outputs selectable
HMM211
HMM212
Digital output
HMM213
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
0 ... 20 mA
4 ... 20mA (loop powered)
RS232
Operating temperature range
Probe
-70 ... +180 °C (-94 ... +356 °F)
Electronics
-5 ... +55 °C (+23 ... +131 °F)
Storage temperature range
(Electronics)
-40 ... +70 °C (-40 ... +158 °F)
Sensor protection (standard)
stainless steel sintered filter
Connections
screw terminals for 0.5 ... 1.5 mm2 wires
Power Supply
Operating voltage
10 ... 35 VDC
In modules with analog outputs the supply range depends to a
certain extent on the selected output range.
Current consumption without sensor head
warming or re-gaining option
HMM211 & HMM213
12 mA at 35 VDC
Configuration Options
Compatible with modules:
PROBES
HMM211
HMM212
HMM213
RH+T
Dewpoint (heated
composite sensor)
Temperature
yes
yes
yes
yes
yes
yes
yes
CABLE LENGTHS
RH+T and Dewpoint probes
Temperature probe
CHEMICAL PURGE
65, 150 and 300 cm
150 and 300 cm
Automatically takes place at power-up
HUMICAP® is a registered trademark of Vaisala.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210901EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
39
www.vaisala.com
HMM100 Humidity Module for Environmental
Chambers
Technical data
Performance
Mechanics
RELATIVE HUMIDITY
Service cable connector
Probe diameter
Probe cable lengths
Probe material
plastics
stainless steel
Probe mounting clamp
Mounting bracket material
lid
bottom plate
Module housing material
Measurement range
0 ... 100 %RH
Accuracy (incl. non-linearity, hysteresis
and repeatability)
temperature range
-20 ... +40 °C
0 ... 90 %RH
±2 %RH
90 ... 100 %RH
±3 %RH
temperature range
-40 ... -20 °C, +40 ... +180 °C
0 ... 90 %RH
±2.5 %RH
90 ... 100 %RH
±3.5 %RH
Factory calibration uncertainty (+20 °C)
±1.5 %RH
Humidity sensor
Vaisala HUMICAP® 180R
M8 series 4-pin (male)
12 mm
0.6/1.55/2.9 m
PPS
AISI316/PPS
AISI316
ABS/PC
Al
ABS/PC (cover)
DEW POINT TEMPERATURE
Measurement range
-20 ... +100 °C (-4 ... +212 °F)Td
Accuracy (incl. non-linearity, hysteresis and repeatability
when dew point depression <20 °C
±2 °C Td
(Ambient temperature - dew point)
Operating environment
The Vaisala HUMICAP® Humidity Module HMM100.
Features/Benefits
The HMM100
▪
The Vaisala HUMICAP® Humidity
Module HMM100 is an open
frame module for integration into
environmental chambers. The
modules provide a single analog
output channel for relative humidity
(RH) or dewpoint (Td).
▪
▪
Full temperature compensation
over the operating temperature
range of -70˚C ... +180˚C
High temperature tolerance,
also suitable for heatsterilization
Easy to install
Robust and reliable
Applications: test chambers,
incubators
The HMM100 probe works in freezing
conditions (-70 °C) and also in
temperatures up to +180 °C. The
Accessories
The accessories available are a
component board mounting bracket
with a lid, probe clamp, USB-cable for
service use, a module housing and a
probe mounting flange.
1.93
49
Input and outputs
1.21
30.7
Operating voltage
2-wire model
3-wire model
24 VDC
10 ... 35 VDC or 24 VAC
15 ... 35 VDC or 24 VAC when 0 ... 10 V
output is used
Power consumption
6 mA
Analog output types (1 output selectable)
2-wire model
4 ... 20 mA (loop-powered)
3-wire model
0 ... 20 mA, 0 ... 1 V/5 V/10 V
Max. wire size
0.5 ... 1. 5 mm2 (AWG)
Service port
M8 connector for USB cable
For more information, visit
www.vaisala.com or contact
us at [email protected]
40
2.12
54
1.83
46.5
Maintenance-free
2.17
55
0.14
3.5
▪
▪
▪
Easy field calibration by
trimmers
See Table
AW 7 [0.28]
Durable
Compared to psychrometers, the
HMM100 is practically maintenancefree. There is no wick that needs
changing and there is no need for
a water tank or water pump. Thus,
environmental stress screening can
be done reliably.
HUMICAP180R
10159HM
6221
219452SP
HM47280SP
225979
226060
226061
226067
226068
Dimensions
0.47
12
▪
▪
Two probes are available, one made
of plastics, the other of stainless
steel. Several cable lengths up to
3 meters are available. Both the
probes have the Vaisala HUMICAP®
180R sensor which ensures excellent
measurement accuracy.
Maintenance-free
Humidity sensor
Membrane filter
Plastic grid filter
Porous PTFE filter
Stainless steel sintered filter
Mounting bracket with lid
Module housing (IP65)
Probe mounting flange
Probe mounting clamp set (10 pcs)
USB cable
1.44
36.5
Excellent measurement
accuracy with Vaisala
HUMICAP® 180R sensor
HMM100 is easy to install and the
probe can be freely placed in a test
chamber as the speed of airflow does
not affect the measurement.
Operating temperature range
component board
-5 ... +55 °C (+23 ... +131 °F)
stainless steel and plastic
probe
-70 ... +180 °C (-94 ... +356 °F)
porous PTFE filter stainless
steel, sintered filter
-70 ... +180 °C (-94 ... +356 °F)
plastic grid, membrane filter
-20 ... +80 °C (-4 ... +176 °F)
Electromagnetic compatibility
Complies with EMC standard
EN61326-1, for use in light industrial environments
Options and accessories
Ref. B210813EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
41
Performance
RELATIVE HUMIDITY
Measurement range
Typical accuracy
temperature range
0 ... 90 %RH
90 ... 100 %RH
temperature range
0 ... 90 %RH
90 ... 100 %RH
Humidity sensor
0 ... 100 %RH
0 ... +40 °C
±3 %RH
±5 %RH
-40 ... 0 °C, +40 ... +60 °C
±5 %RH
±7 %RH
Vaisala INTERCAP®
TEMPERATURE
Measurement range
Accuracy over temperature range -40 ... +60 °C
-40 ... +60 °C
±0.6 °C
DEW POINT
Measurement range
-40 ... +60 °C
Typical accuracy
temperature range
0 ... +40 °C
when dew point depression < 15 °C
±2 °C
temperature range
-40 ... 0 °C, +40 ... +60 °C
when dew point depression < 10 °C
±3 °C
dew point depression = ambient temperature - dew point
The HMP60 for extreme conditions.
Features/Benefits
HMP60
Several outputs
▪
▪
▪
The HMP60 is a simple, durable and
cost-effective humidity probe. It is
suitable for volume applications,
integration into other manufacturers’
equipment, incubators, glove boxes,
greenhouses, fermentation chambers,
and data loggers.
There are two configurable voltage
outputs with relative humidity,
temperature or dew point scaling.
Four voltage output ranges are
available.
Miniature-size humidity probe
Low power consumption
Measurement range:
0 ... 100 %RH; -40 ... +60°C
▪
Cable detachable with
standard M8 connector
▪
▪
Rugged metal housing
Easy installation
Interchangeable Vaisala
INTERCAP® Sensor
▪
Optional RS485 digital output
The probe cable has a screw-on
quick connector for easy installation.
Different cable lengths are available.
Also other compatible M8 series cables
can be used. Accessories are available
for different installation needs.
Optional dew point output
▪
42
Applications: volume
applications, integration
into other manufacturers’
equipment, glove boxes,
greenhouses, fermentation
chambers, data loggers
Low current consumption
The HMP60 is suitable for batterypowered applications because of its
very low current consumption.
Rugged design
The HMP60 is designed for extreme
conditions. The aluminum body of
the HMP60 is classified as IP65.
The probe has a sealed structure
and the sensor is protected by a
membrane filter and a plastic grid,
or optionally by a stainless steel filter.
Recalibration not needed
The Vaisala INTERCAP® Sensor is
interchangeable. No recalibration is
required; the sensor can simply be
replaced, also in the field.
Operating environment
Operating temperature
Electromagnetic compatibility
-40 ... +60 °C
Complies with EMC standard
EN61326-1, Basic immunity test
requirements
Inputs and outputs
Operating voltage
(Use lowest available operating
voltage to minimize heating.)
5 ... 28 VDC / 8 ... 28 VDC with
5 V output
8 ... 28VDC with loop power
converter
1 mA average, max. peak 5 mA
<14 V: 1 s; >14 V: 4 s
Current consumption
Start-up time at operating voltage
Outputs
2 channels
0 ... 1 VDC/0 ... 2.5 VDC / 0 ... 5 VDC/1 ... 5 VDC
1-channel loop-power converter (separate
module, compatible with humidity accuracy only)
4 ... 20 mA
digital output (optional)
RS485 2-wire half duplex
For more information, visit
www.vaisala.com or contact
us at [email protected]
External loads
0 ... 1 V
0 ... 2.5 V /0 ... 5 V
RL min 10 kΩ
RL min 50 kΩ
Mechanics
Materials
body
grid filter
cable
Housing classification
Body thread
Cable connector
Weight with 0.3 m cable
chrome coated aluminum
chrome coated ABS plastic
polyurethane or FEP
IP65
MI2x1 / 10 mm
4-pin M8 (IEC 60947-5-2)
23 g
Options and accessories
Vaisala INTERCAP® Sensor, 1 piece
Vaisala INTERCAP® Sensor, 10 pcs
Sensor protection
plastic grid
membrane filter
stainless steel sintered filter
4 ... 20mA loop power converter
Mounting bracket with lid
Plastic M12 installation nuts, pair
USB cable for PC connection
Probe mounting clamp set, 10 pcs
Probe mounting flange
Connection cables
0.3 m PU
3 m PU
180°C 3 m FEP
15778HM
INTERCAPSET-10PCS
DRW010522
DRW010525
HM46670SP
UI-CONVERTER-1
225979
18350SP
219690
226067
226061
HMP50Z032
HMP50Z30A
226902
Dimensions
in mm (inches)
(2.8)
71
(0.47)
12
Vaisala INTERCAP® Humidity and Temperature
Probe HMP60
Technical data
M12 x1
www.vaisala.com
Ref. B210851EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
43
www.vaisala.com
Technical data
Vaisala HUMICAP® Humidity and Temperature
Probe HMP110
Performance
Start-up time at operating voltage
RELATIVE HUMIDITY
Measurement range
0 ... 100 %RH
Accuracy (incl. non-linearity, hysteresis and repeatability)
temperature range
0 ... +40 °C
0 ... 90 %RH
±1.7 %RH
90 ... 100 %RH
±2.5 %RH
temperature range
-40 ... 0 °C, +40 ... +80 °C
0 ... 90 %RH
±3.0%RH
90 ... 100 %RH
±4.0%RH
Factory calibration uncertainty (+20 °C)
± 1.5%RH
Humidity sensor
Vaisala HUMICAP® 180R
Stability
±2 %RH over 2 years
Outputs
2 channels
<14 V: 1 s
>14 V: 4 s
0 ... 1 VDC/0 ... 2.5 VDC /
0 ... 5 VDC/1 ... 5 VDC
1-channel loop-power converter
(separate module, compatible
with humidity accuracy only)
digital output (optional)
External loads
0 ... 1 V
0 ... 2.5 V /0 ... 5 V
4 ... 20 mA
RS485 2-wire half duplex
RL min 10 kΩ
RL min 50 kΩ
TEMPERATURE
Measurement range
-40 ... +80 °C
Accuracy over temperature range
0 ... +40 °C,
±0.2 °C
-40 ... 0 °C, +40 ... +80 °C
±0.4 °C
Temperature sensor
Pt1000 RTD 1/3, Class B IEC 751
DEW POINT
The HMP110 with excellent stability and high chemical tolerance.
Features/Benefits
HMP110
Several outputs
▪
Miniature-size humidity
transmitter
▪
Low power consumption
and fast startup for battery
powered applications
The temperature measurement
is a standard feature, dew point
measurement is optional. Three
standard voltage outputs are
available.
▪
Measurement range:
0 ... 100 %RH; -40 ... +80°C
▪
Cable detachable with
standard M8 quick connector
▪
The HMP110 is a trouble-free and
cost-effective humidity transmitter
with high accuracy and good
stability. It is suitable for volume
applications or integration into other
manufacturers’ equipment. The
HMP110 is also suitable for glove
boxes, greenhouses, fermentation
and stability chambers, data loggers,
and incubators.
Reliable: Latest generation
HUMICAP® 180R sensor for
best stability and high chemical
tolerance. IP65 metal housing.
▪
▪
Optional RS485 digital output
Traceable: Comes with
calibration certificate. ±1.7%RH
measurement accuracy
(0 ... 90%RH)
▪
HMP110R replacement probe
service available for easy
maintenance
▪
Optional dew point calculation
44
Easy installation
The probe cable has a screw-on
quick connector for easy installation.
Different cable lengths and
accessories are available.
Low current consumption
HMP110 is suitable for batterypowered applications because of its
very low current consumption. It also
has a fast start-up time.
Robust design
The aluminum body of the HMP110
is classified as IP65. Thus, it survives
rough conditions. The HMP110 has
high chemical tolerance because of
the HUMICAP® 180R sensor.
Easy maintenance
Maintaining measurement
traceability is easy using the
HMP110R replacement probe. We
send you a replacement probe, you
detach the old probe and send it back
to us. In this way the measurement
is available at all times without
interruptions.
Measurement range
-40 ... +80 °C
Accuracy (incl. non-linearity, hysteresis and repeatability)
temperature range
0 ... +40 °C
when dew point depression < 15 °C
±1 °C
when dew point depression 15 ... 25°C
±2 °C
temperature range
-40 ... 0 °C, +40 ... +80 °C
when dew point depression < 15 °C - dew point
±2 °C
depression = ambient temperature - dew point
Operating environment
Measurement range
Electromagnetic compatibility
-40 ... +80 °C
Complies with EMC standard
EN61326-1, Basic immunity test
requirements
Inputs and outputs
Operating voltage
(Use lowest available operating
voltage to minimize heating)
Current consumption
5 ... 28 VDC / 8 ... 28 VDC with
5 V output
8 ... 28VDC with loop power
converter
1 mA average, max. peak 5 mA
For more information, visit
www.vaisala.com or contact
us at [email protected]
Mechanics
Materials
body
grid filter
cable
Housing classification
Body thread
Cable connector
Weight with 0.3 m cable
chrome coated aluminum
chrome coated ABS plastic
polyurethane or FEP
IP65
MI2x1 / 10 mm
4-pin M8 (IEC 60947-5-2)
23 g
Options and accessories
Sensor protection
plastic grid
membrane filter
stainless steel sintered filter
4 ... 20mA loop power converter
Mounting bracket with lid
Plastic M12 installation nuts, pair
USB cable for PC connection
Probe mounting clamp set, 10 pcs
Probe mounting flange
Connection cables
standard 0.3 m
standard 3 m
80 °C 1.5 m
80 °C 3 m
180 °C 3 m FEP
DRW010522
DRW010525
HM46670SP
UI-CONVERTER-1
225979
18350SP
219690
226067
226061
HMP50Z032
HMP50Z30A
225777SP
225229SP
226902
Ref. B210852EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
45
www.vaisala.com
HM70 Hand-Held Humidity and Temperature
Meter for Spot-Checking Applications
Technical data
HMP75, HMP76 and HMP77 probes
Measured variables
MI70 measurement indicator
Indicator general
RELATIVE HUMIDITY
Menu languages
Measurement range
0 ... 100 %RH
Accuracy (including nonlinearity, hysteresis and repeatability)
at +15 ... +25 °C (+59 ... +77 °F)
±1 %RH (0 ... 90 %RH)
±1.7 %RH (90 ... 100 %RH)
at -20 ... +40 °C (-4 ... +104 °F)
±(1.0 + 0.008 x reading) %RH
at -40 ... +180 °C (-40 ... +356 °F)
±(1.5 + 0.015 x reading) %RH
Factory calibration
±0.6 %RH (0 ... 40 %RH)
uncertainty (+20 °C / +68 °F)
±1.0 %RH (40 ... 97 %RH)
(Defined as ±2 standard deviation limits.)
Response time (90%) at +20 °C (+68 °F) in still air
HMP75 (with standard plastic grid)
17 s
HMP76 (with standard sintered bronze filter)
60 s
HMP77 (with standard plastic grid and stainless
50 s
steel netting)
Sensor
HUMICAP® 180R
®
HUMICAP 180RC (chemical purge, sensor preheat)
Typical long-term stability
better than 1 %RH / year
TEMPERATURE
The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 is a highperformance, portable humidity reference that is exciting to use.
Features/Benefits
▪
▪
▪
▪
Multilingual user interface
Shows measurement trends
graphically
Proven Vaisala HUMICAP®
Sensor technology
3 probe alternatives,
temperature measurement
ranges between -70 and
+180 °C
▪
Multiprobe operation; dewpoint
and CO2 probes can also be
connected
▪
2 probes can be connected
simultaneously
▪
Displays various humidity
parameters
▪
Sensor preheat and chemical
purge options for demanding
conditions
▪
46
NIST traceable (certificate
included)
®
The Vaisala HUMICAP Hand-Held
Humidity and Temperature Meter
HM70 is designed for demanding
humidity measurements in spotchecking applications. It is also ideal
for field checking and calibration of
Vaisala's fixed humidity instruments.
The HM70 incorporates the latest
generation of the Vaisala HUMICAP®
Sensor. It is reliable and has better
than ever long-term stability.
Additionally, it has a sensor that
copes well with chemical interference
and provides accuracy that lasts in
demanding conditions.
The chemical purge option
maintains measurement accuracy
in environments with high
concentrations of chemicals. The
sensor preheat option reduces
measurement delays as it keeps
the sensor dry when the probe
is inserted into hot and humid
processes.
Three probes
to choose from
The HMP75 is a general purpose
probe whereas the HMP76 is a long,
stainless steel probe especially
suitable for spot-checking in ducts.
The HMP77 is a small probe at the
end of a 5-meter cable. The probe is
ideal for difficult-to-reach areas and
for on-site calibration of Vaisala's
process transmitters.
In addition, the HM70 supports the
use of Vaisala's dewpoint, carbon
dioxide and moisture in oil probes,
allowing measurements in several
multiparameter applications.
MI70 Link
The optional MI70 Link Windows®
software and the USB connection
cable form a practical tool for
transferring logged data and real
time measurement data from the
HM70 to a PC.
Measurement range
HMP75
HMP76
short time
HMP77
Accuracy at +20 °C (+68 °F)
Accuracy over temperature range
-20 ... +60 °C (-4 ... +140 °F)
-50 ... +120 °C (-58 ... +248 F)
-50 ... +180 °C (-58 ... +356 °F)
-70 ... +180 °C (-94 ... +356 °F)
±0.2 °C (±0.36 °F)
(see graph)
°C
0.7
0.6
0.5
0.4
0.3
0.2
0.1
°C
0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-80
-60
-40
-20
0
20
Temperature sensor
40
60
80
100
120
140
160
180
Pt100 IEC751 1/3 class B
Probe general
Operating temperature range for electronics
-40 ... +60 °C
(-40 ... +140 °F)
Housing classification
IP65 (NEMA 4)
Housing material
ABS/PC blend
Probe material
Stainless steel (AISI316L)
Cable length between probe and indicator
1.9 m
For more information, visit
www.vaisala.com or contact
us at [email protected]
English, Chinese, French, Spanish, German,
Russian, Japanese, Swedish, Finnish
Display
LCD with backlight, graphic trend display of
any parameter, character height up to 16 mm
Max. no. of probes
2
Power supply
Rechargeable NiMH battery pack with ACadapter or 4xAA-size alkalines, type IEC LR6 0
Analog output
0... 1 VDC
Output resolution
0.6 mV
PC interface
MI70 Link software with USB or
serial port cable
Data logging capacity
2700 points
Alarm
audible alarm function
Operating temperature
range
-10 ... +40 °C (+14 ... +104 °F)
Operating humidity range
non-condensing
Housing classification
IP54
Battery operation time
Continuous use
48 h typical at +20 °C (+68 F)
Data logging use
up to a month, depending on logging
interval
Electromagnetic
Complies with EMC standard
compatibility
EN61326-1, Portable Equipment
MI70 indicator + probe = HM70
ACCESSORIES
Carrying cases
for MI70 and HMP75/77 probe
for MI70 and HMP75/76 probe
Transmitter connection cables for
HMT330 & HMT100 Series
HM60/70/140 Series
MI70 Link software with USB cable
MI70 Link software with serial port cable
Analog output cable
Sensor protection HMP75
Plastic PC grid (HMP75 standard)
Membrane filter
Sintered bronze filter
HMP76/77
Plastic PPS grid
Sintered stainless steel filter
Sintered bronze filter (HMP76 standard)
PPS grid with SS netting (HMP77 standard)
MI70CASE
MI70CASE2
211339
HMA6070
219687
MI70LINK
27168ZZ
6221
10159HM
DRW212987SP
DRW010276SP
HM47280SP
DRW212987SP
DRW010281SP
Ref. B210435EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
47
www.vaisala.com
HMI41 Indicator and
HMP46 High Temperature Probe
The Vaisala HUMICAP® Humidity
Indicator HMI41 fitted with the
Vaisala HUMICAP® Humidity and
Temperature Probe HMP46 can be
used for spot checking humidity
and temperature in ducts or
chambers. Typical applications
are plant maintenance, installation
and inspection of air conditioning
systems, production and storage
areas and production processes.
In addition, it is suitable for field
checking Vaisala's humidity
transmitters.
Withstands high
temperatures
The Vaisala HUMICAP® Humidity
Indicator HMI41 equipped with the
Vaisala HUMICAP® Humidity and
Temperature Probe HMP46 is an ideal
combination for spot checking and field
calibration.
The HMP46 operates in full
humidity range of 0 ... 100 %RH. The
temperature range is from
-40 to +100 °C (-40 ... +212 °F). For
short periods of time, the probe can
withstand temperatures up to
+180 °C (+356 °F).
The HMP46 probe is solid and
rugged. Its stainless steel probe is
made to withstand rough handling
in mechanically demanding
applications. The probe’s long
shaft can also reach otherwise
unreachable places.
Versatile and easy to use
In addition to displaying the humidity
and temperature readings, the HMI41
indicator calculates dewpoint and
wet bulb temperature, absolute
humidity and mixing ratio.
The indicator has an easy-to-read
two line liquid crystal display. The
display units (metric or non-metric)
are easily selected.
Technical data
HMI41 indicator
TEMPERATURE
Calculated variables
Features/Benefits
▪
RH measurement range
0 ... 100 %RH
▪
Temperature measurement
range -40 ... +100 °C
(-40 ... +212 °F),
for short periods up to +180 °C
(+356 °F)
▪
▪
▪
Calculates dewpoint, wet bulb
temperature, absolute humidity
and mixing ratio
Versatile and easy-to-use
Incorporates Vaisala HUMICAP®
Sensor
▪
▪
▪
Excellent stability
▪
Optional carrying case and
calibration cable
▪
Available as a complete
calibration kit HMK41
Data collection with serial line
NIST traceable (certificate
included)
These features, plus fast response
time, high measurement accuracy
and excellent stability, as well as
the wide temperature range of the
probe, make the HMI41/HMP46
combination an ideal choice for the
most demanding applications.
High performance sensor
The HMP46 probe incorporates
Vaisala HUMICAP® Sensor. This
sensor has high accuracy, excellent
long-term stability and negligible
hysteresis. In addition, the sensor is
insensitive to dust, particulate dirt
and most chemicals.
dewpoint temperature,
absolute humidity,
wet bulb temperature, mixing ratio
0.1 %RH; 0.1 °C/°F
4 batteries, type AA (LR 6)
Resolution
Power supply
Battery operation time
(alkaline batteries)
72 h continuous use
Auto-off function
Operating temperature
-20 ... +60 °C (-4 ... +140 °F)
Storage temperature
-40 ... +70 °C (-40 ... +158 °F)
Display
two line LCD
Housing material
ABS plastic
Housing classification
IP53 (with connectors blocked)
Weight (incl. batteries)
300 g
Maximum measurement error of indicator at +20 °C
humidity
±0.1 %RH
temperature
±0.1 °C (±0.18 °F)
#
Temperature sensor
4 #
Pt 100 IEC 751 1/3 class B
HMP46 probe
General
HUMIDITY
Typical ranges of calculated variables
dewpoint temperature
-20 ... +100 °C (-4 ... +100 °F)
absolute humidity
0 ... 600 g/m3
wet bulb temperature
0 ... 100 °C (32 ... 212 °F)
mixing ratio
0 ... 600 g/kg d.a.
The accuracies of these calculated variables are limited by the
accuracies of the measured variables on which they are based,
namely RH and T. The RH and T accuracies are stated under
HMP46 probe.
Measurement range
0 ... 100 %RH, non-condensing
Accuracy (incl. nonlinearity, hysteresis and repeatibility) at +20 °C
Maximum achievable accuracy when calibrated against
high quality, certified humidity standards:
0 ... 90 %RH
±1 %RH
90 ... 100 %RH
±2 %RH
When calibrated against salt solutions (ASTM E104-85)
0 ... 90 %RH
±2 %RH
90 ... 100 %RH
±3 %RH
Temperature Dependence
ERROR2(
FORTEMPORARY
USEONLY
4 #
Typical long-term stability
Response time (90%)
at +20 °C in still air w/sintered filter
Humidity sensor
better than 1 %RH per year
15 s
HUMICAP® 180
For more information, visit
www.vaisala.com or contact
us at [email protected]
48
Continuous measurement
-40 ... +100 °C (-40 ... +212 °F)
Short-term measurement
-40 ... +180 °C (-40 ... +356 °F)
Accuracy at +20 °C (+68 °F)
±0.2 °C (±0.36 °F)
Accuracy over the measurement range
Cable length
1500 mm; extended spiral cable
Operating temperature range
for electronics
-20 ... +60 °C (-4 ... +140 °F)
Housing material
Electronics housing
ABS plastic
Probe
stainless steel
Housing classification
electronics
IP65 (NEMA 4)
Sensor protection
sintered filter, part no. 0195
optionmembrane filter, part no. 10159HM (max +80 °C / +176 °F)
plastic grid, part no. 6221 (max +80 °C / +176 °F)
Weight
450 g
Electromagnetic compatibility
Complies with EMC standard
EN61326-1, Portable Equipment
Ref. B210940EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
49
www.vaisala.com
HMP41, HMP42 and HMP45 Probes
for HMI41 Indicator
Vaisala HUMICAP® Humidity Indicator
HMI41 can be used with any one of
the four probes to quickly and easily
measure humidity and temperature,
and to make other measurement
calculations such as dewpoint, wet
bulb temperature, absolute humidity
and mixing ratio.
The HMI41 indicator with the HMP41
probe.
The HMI41 has an easy-to-read LCD
display. Temperature readout is
available in either degrees Centigrade
or Fahrenheit. Calculated variables
are available in metric and nonmetric format.
Ideal for spot checking
applications
The HMI41 indicator with probes
is ideal for use in a variety of spot
checking applications such as plant
maintenance, air-conditioning system
installation and inspection, freezers
and storage and production areas.
Vaisala HUMICAP®
Humidity and
Temperature Probe
HMP41:
HMI41 with the HMP42 probe.
HMI41 with the HMP45 probe.
50
HMP41, HMP42, and HMP45 probes
HUMIDITY
Features/Benefits
▪
Humidity measurement range
0 ... 100 %RH
▪
Temperature measurement
range HMP41, HMP45: -20 ...
+60 °C (-4 ... +140 °F) HMP42:
-40 ... +100 °C (-40 ... +212 °F)
▪
For spot checking
measurements
▪
▪
Versatile and easy-to-use
▪
Extremely thin 4 mm probe
head (HMP42)
▪
Incorporates Vaisala HUMICAP®
Sensor, which provides high
accuracy, excellent long-term
stability, neglible hysteresis,
and insensitivity to dust and
most chemicals
▪
The HMI41 Indicator can be
used with any of the four
available probes
NIST traceable
(certificate included)
r JOUJHIUQMBDFT
r JOEVDUTPSDIBNCFST
This probe is fix-mounted directly
on the HMI41 indicator. It can be
upgraded to an HMP45 by purchasing
the HMH45 handle and cable option.
r VOEFSBMJOPMFVNGMPPS
Vaisala HUMICAP®
Humidity and
Temperature Probe
HMP42:
Vaisala HUMICAP®
Humidity and
Temperature Probe
HMP45:
The HMP42 probe can be used
for spot checking humidity and
temperature in applications which
require an extremely thin probe,
such as:
This probe for general purposes
features an extended spiral cable.
r GPSNPOJUPSJOHUIFESZJOHPG
structures during construction or
after water damage
Technical data
The probe diameter is only 4 mm,
allowing access into very small, tight,
and hard-to-reach spaces.
Vaisala HUMICAP®
Humidity and
Temperature Probe
HMP46:
See preceding data sheet.
Measurement range
0 ... 100 %RH
Accuracy at +20 °C (+68 °F)
when calibrated against salt
±2 %RH (0 ... 90 %RH)
solutions (ASTM E014-85)
±3 %RH (90 ... 100 %RH)
Temperature dependence of electronics
±0.05 %RH/°C
Typical long-term stability
better than 1 %RH per year
Response time (90%) at +20 °C in still air
(HMP41, HMP45) 15 s
(HMP42) 30 s
Sensor HMP41 & 45
HUMICAP® 180
Sensor HMP42
HUMICAP® MINI
TEMPERATURE
Measurement range probe
HMP41, HMP45
-20 ... +60 °C (-4 ... +140 °F)
HMP42
-40 ... +100 °C (-40 ... +212 °F)
Temperature accuracy over measurement range
Sensor (HMP41 & 45)
PT 1000 IEC 751 1/3 class B
(HMP 42)
PT 100 IEC 751 class B
Battery operation time (alkaline batteries)
72 h continuous use
Housing material
ABS plastic
Housing classification, electronics
IP65 (NEMA 4)
Sensor protection
HMP41 & 45
plastic grid
HM46717
option
membrane filter
2787HM
HMP42
steel grid
19867HM
membrane
tube set (5pcs)
19858HM
Weight
HMP41
30 g
HMP42
200 g
HMP45
160 g
Electromagnetic compatibility
Complies with EMC standard
EN61326-1, Portable Equipment.
Accessories
Serial interface cable
Carrying case for HMI41 and HMP41/45
Aluminum case for HMP41/42/45/46
Rigid plastic case for HMP41/42/45/46
HMP42
Calibration adapter
Rubber sleeve set
19446ZZ
HM36736
MI70CASE2
210614
HM37067
19809HM
Dimensions
Dimensions in mm.
HMI41
HMP41
HMP42
HMP45
30
30
General
38
88
Typical ranges of calculated variables
dewpoint temperature
-20 ... +60 °C (-4 ... +140 °F)
absolute humidity
0 ... 160 g/m3
wet bulb temperature
0 ... +60 °C (32 ... +140 °F)
mixing ratio
0 ... 160 g/Kg d.a.
The accuracies of these calculated variables are limited by the
accuracies of the measured variables on which they are based,
namely RH and T. The RH and T accuracies are stated above in the
probe section.
Cable length (HMP42 & 45)
1500 mm; extended spiral cable
Operating temperature range
HMP41
-20 ... +60 °C (-4 ... +140°F)
HMP42
-40 ... +100 °C (-40 ... +212 °F)
HMP45
-40 ... +60 °C (-40 ... +140 °F)
For more information, visit
www.vaisala.com or contact
us at [email protected]
118
Ø 18.5
Ø 18.5
Ø 21
237
13
318
106
200
125
75
80
3 7
HUMICAP® is a registered trademark of Vaisala.
Ref. B210941EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
51
www.vaisala.com
Technical data
HM34 Pocket Size Relative Humidity Meter
The Vaisala HUMICAP® Hand-Held
Humidity and Temperature Meter
HM34 provides a fast and convenient
way to accurately spot-check relative
humidity and temperature.
Fast and easy-to-use
In measurement mode, the
extendable probe just slides out.
Normally, measurement takes only
a few seconds. The HM34 meter
includes a HOLD button which
allows the user to retain an RH or T
measurement until it has been noted
or recorded.
▪
Ideal for spot checking
humidity levels
▪
▪
▪
Measurement range 0 ... 100 %RH
Incorporates Vaisala HUMICAP®
Sensor that provides high
accuracy, excellent long-term
stability, neglible hysteresis,
and insensitivity to dust and
most chemicals
▪
Temperature measurement
range -20 ... +60 °C
(-4 ... +140 °F)
▪
▪
Available in either °F or °C
Lightweight, pocket-sized
▪
Each unit comes with a 9V
battery, attached probe, 0.2 μm
protective membrane filter and
a carrying case
▪
▪
▪
Fast response with ±2%
accuracy
Extendable probe
Automatic POWER-OFF
Display
Hold function
Power supply
Battery operation time
Automatic POWER OFF
Response time (90%)
After the measurement is completed,
the probe is slid back into the meter
casing. Between spot checks, the
meter is normally stored in its
carrying case.
Features/Benefits
General
Measurement range
Accuracy
0 ... 100 %RH
±2% (0 ... 90 %RH)
±3% (90 ... 100 %RH)
Resolution
0.1 %RH
Temperature dependence
±0.04 %RH/°C
Sensor type
HUMICAP®H thin film capacitive sensor
If no buttons are pressed for three
minutes, the unit automatically
switches itself off. This automatic
POWER-OFF function prevents the
possibility of accidental discharge of
the HM34’s battery.
Features/Benefits
Relative humidity
15 s with membrane filter
5 s with plastic grid
Temperature
Range
Accuracy
Resolution
Temperature dependence
Sensor
-20 ... +60 °C (-4 ... +140 °F)
±0.3 °C (±0.54 °F)
0.1 °C (0.1 °F)
±0.02 °C/°C (±0.02 °F/°F)
Pt 100 IEC 751 1/3 Class B
The Vaisala HUMICAP® Hand-Held
Humidity and Temperature Meter
HM34 provides accurate spot checks of
humidity and temperature.
NIST traceable (certificate
included)
For more information, visit
www.vaisala.com or contact
us at [email protected]
52
3 1/2 digit LCD
Push-button hold of displayed value
9 V battery
50 h
after 3 minutes,
unless HOLD is activated
Operating temperature range
-20 ... +60 °C (-4 ... +140 °F)
Housing
ABC plastic
Sensor protection
standard
plastic grid, part no. 6221
optional
sintered filter 133 mm, part no. 0195
Weight
180 g with battery
Ordering Information
HM34C
with °C temperature reading
HM34F
with °F temperature reading
Electromagnetic compatibility
Complies with EMC standard
EN61326-1, Portable Equipment
Ref. B210909EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
53
www.vaisala.com
Vaisala HUMICAP® Humidity and Temperature
Transmitters HMT120 and HMT130
Features/Benefits
The HMT120/130 with and without a display.
The Vaisala HUMICAP® Humidity and
Temperature Transmittersw HMT120
and HMT130 are designed for
humidity and temperature monitoring
in cleanrooms and are also suitable
for demanding HVAC applications.
Performance
The HMT120/130 incorporates Vaisala
HUMICAP® technology that measures
relative humidity accurately and
reliably. The Vaisala HUMICAP® is
resistant to dust and most chemicals.
The transmitter enclosure is
optimized for use in cleanrooms.
The smooth surface of the enclosure
makes it easy to clean and the
enclosure material is chosen
to tolerate purifying agents.
Furthermore, the cabling can be
done through the back wall of the
transmitter.
Interchangeable Probe
The HMT120/130 transmitters use
a fully interchangeable relative
humity probe. The probe can be
easily removed and replaced with
a new one without having to adjust
the transmitter, which allows for
easy and quick recalibration of
the transmitter. The probe can
be adjusted using one of Vaisala’s
portable meters as a reference.
Also available is a constant output
probe with fixed RH and T output
for convenient inspection of the
monitoring system and signal
transfer line.
▪
Vaisala HUMICAP® technology
with humidity sensor
HUMICAP® 180R
▪
2-wire loop-powered or 3-wire
voltage output configurations
▪
Interchangeable probe
(easy field calibration)
▪
▪
Accurate and reliable
▪
▪
Optional LCD display
▪
Wall-mounted or with a
remote probe
▪
Constant output probe
available
▪
Can be mounted outdoors
using a Vaisala installation
kit and the Vaisala Radiation
Shield DTR502B
▪
▪
Enclosure IP65
Resistant to dust and most
chemicals
USB cable available for a PC
connection for maintenance
Suitable for cleanrooms and
demanding HVAC applications
Available Options
The HMT120 and HMT130
transmitters are available as wall
mounted or with remote probe. For
high temperature applications or
where space is limited, the remote
probe is ideal. The transmitters
come with an optional, LCD display,
which shows the measurement
results of selected parameters in
selected units. The parameters
are displayed simultaeously at two
separate rows on the display.
Technical Data
Performance
Mechanics
RELATIVE HUMIDITY
Material
transmitter housing
display window
probe body
probe grid filter
Housing classification
Connections
inputs and outputs
probe interface
Probe cable lengths
Display (optional)
Measurement range
-40 °C ... +80 °C
Accuracy over temperature range
at +15 °C ... +25 °C
±0.2 °C
at 0 ... +15 °C and at +25 °C ... +40 °C
±0.25 °C
at -40 °C ... +0 °C and at +40 °C ... +80 °C
±0.4 °C
Temperature sensor
Pt1000 RTD 1/3 Class B IEC 751
Operating temperature range
transmitter body, no display
-40 °C ... +60 °C
transmitter body, with display
-20 °C ... +60 °C
HMP110 probe
-40 °C ... +80 °C
Storage temperature range
-50 °C ... +70 °C
Electromagnetic compatibility
EN 61326-1
and EN 55022
Inputs and outputs
HMT120 TWO-WIRE TRANSMITTER (LOOP POWERED)
Current output signals
External loop voltage
4 ... 20 mA
10 ... 30 VDC (RL= 0 ohms)
20 ... 30 VDC (RL< 500 ohms)
HMT130 THREE-WIRE TRANSMITTER
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
or user defined between 0 ... 10 V
Min output resistance
1 kohm
Serial output
RS485, non-isolated
Relay output
1 relay (max. 50 VDC, 200 mA)
Supply voltage
10 ... 35 VDC
15 ... 35 VDC (when output 0 ... 10 V)
24 VAC (±20 %)
Current consumption at 24 VDC
8 mA, if relay closed 15 mA
Max. additional error caused by the
analog outputs after calibration at
+20 °C ambient temperature
±0.1 % of FS output signal
Temperature dependence of the
analog outputs
±0.005 % of FS output signal
Screw terminals 0.5 ... 1.5 mm2
4-pin M8 female panel connector
3 m, 5 m, 10 m - up to 50 m
128 x 64 resolution full graphics
B&W display without backlight
270 g
Weigth (including probe)
Accessories
Humidity and temperature probe
Humidity and temperature replacement probe
Constant output probe
Humidity sensor
Probe mounting flange
Probe mounting clamps, 10 pcs
HMP110 sensor protection
plastic grid filter
plastic grid with membrane filter
stainless steel sintered filter
Probe cable 3 m
Probe cable 5 m
Probe cable 10 m
Radiation shield
Probe installation kit for DTR502
Rain shield with installation kit
Duct installation kit
HMI41 connection cable
HM70 connection cable
USB serial interface cable
* See separate order form
HMP110*
HMP110R*
HMP110REF*
HUMICAP® 180R
226061
226067
DRW010522SP
DRW010525
HM46670SP
HMT120Z300
HMT120Z500
HMT120Z1000
DTR502B
210623
215109
215619
25917ZZ
211339
219685
116
120
Wall Assembly dimensions
78
M4
;4
pc
s
39
46
92
72
Voltage output signals
PBT plastic
PC plastic
Chrome coated aluminum
Chrome coated ABS plastic
IP65
91
TEMPERATURE
145
Measurement range
0 ... 100 %RH
Accuracy including non-linearity, hysteresis, and repeatability
at 0 °C ... +40 °C
±1.7 %RH (0 ... 90 %RH)
±2.5 %RH (90 ... 100 %RH)
at -40 °C ... +0 °C and
±3.0 %RH (0 ... 90 %RH)
at +40 °C ... +80 °C
±4.0 %RH (90 ... 100 %RH)
Factory calibration uncertainty at +20 °C (+68 °F)
±1.5 %RH
Humidity sensor
Vaisala HUMICAP® 180R
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B211086EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
www.vaisala.com
Technical data
HMK15 Humidity Calibrator
accepted and reliable method to
calibrate humidity instruments.
Usually two or three different salt
solutions are used. Salts are chosen
according to the application.
three step plugs to fit all
chamber holes (12 mm,
13.5 mm and 18.5 mm)
transit covers
for secure
transportation
and long-term
storage
Certified salts
The HMK15 can be ordered with
certified and pre-measured salts.
A sample calibration is made from
each batch in Vaisala’s Measurement
Standards Laboratory (MSL).
General
Options
The standard HMK15 consists of the following parts:
Certified and ready
dosed salts:
Order
code:
Total
uncertainty*:
LiCl salt
11 %RH
MgCl2 salt
33 %RH
NaCl salt
75 %RH
97 %RH
K2SO4 salt
*Uncertainties given at +20 °C
19729HM
19730HM
19731HM
19732HM
(±1.3%RH)
(±1.2%RH)
(±1.5%RH)
(±2.0%RH)
Two salt chambers, chamber covers and transit covers
Base plate
Choice of thermometers
mercury thermometer,Vaisala calibrated,
order code 19728HM
thermometer with red capillary liquid, calibrated by
manufacturer, order code 25130HM
Measurement cup and mixing spoon
on exchanged water
Extra salt chambers
Carrying bag
19767HM
19766HM
HM27032
Calibrated thermometer
thermometer with
calibration certificate
In addition to laboratory use,Vaisala Humidity Calibrator HMK15 is suitable for onsite checks of humidity probes and transmitters.
Features/Benefits
No measuring instrument stays
accurate by itself. It is essential that
the functioning of an instrument
is periodically checked against a
reference. Vaisala has developed the
Vaisala Humidity Calibrator HMK15 to
make calibration and spot checking
of humidity probes and transmitters
easy and reliable.
▪
Easy and reliable calibration
of humidity probes and
transmitters
▪
Based on saturated salt
solutions
▪
▪
▪
Fast temperature equilibration
Suitable for laboratory use
and on-site checks
Method used by
leading laboratories
▪
Chambers and transit covers
make HMK15 easy to transport
▪
Pre-measured certified salts
available
▪
Vaisala Service Centers offer
accredited calibrations for
humidity, temperature and
barometric pressure.
The operating principle of the
HMK15 is based on the fact that a
saturated salt solution generates a
certain relative humidity in the air
above it. The reading of the humidity
probe or transmitter can then be
adjusted accordingly. Many leading
laboratories use this generally
54
No external power required
The HMK15 can be ordered with
a thermometer, which is used for
measuring the temperature during
the calibration. It can also be used
for checking the temperature
measurement accuracy of the
transmitter. The thermometer can
contain either mercury (accuracy
±0.3 °C (±0.54 °F)) or red capillary
fluid (accuracy ±1.0 °C (±1.8 °F)).
FINAS approved
Measurement Standards
Laboratory
Vaisala’s Measurement Standards
Laboratory is a FINAS accredited
calibration laboratory. FINAS is a
member of the EA (the European
Cooperation for Accreditation).
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210908EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
55
www.vaisala.com
HMP155 Humidity and Temperature Probe
Technical data
Performance
General
RELATIVE HUMIDITY
Features/Benefits
HMP155 with a new, stable HUMICAP®180R sensor and an additional temperature
probe.
New probe for reliability
The new Vaisala HUMICAP® Humidity
and Temperature Probe HMP155
provides reliable humidity and
temperature measurement.
Long-term stability
The HMP155 has a new generation
Vaisala HUMICAP®180R sensor that
has excellent stability and withstands
well harsh environments. The probe
structure is solid and the sensor is
protected with a sintered teflon filter,
which gives maximum protection
against liquid water, dust, and dirt.
Warmed probe and high
humidity environment
This is an environment to which
Vaisala has designed a patented,
warmed probe for reliable
measuring. As the sensor head is
warmed continuously, the humidity
level inside it stays below the
ambient level. Thus, it also reduces
the risk of condensation forming on
the probe.
Fast temperature
measurement
What’s more, with its fast response
time, the additional temperature
probe for the HMP155 is ideal for
measurement in environments with
changing temperatures.
▪
Vaisala HUMICAP®180R sensor
- superior long-term stability
▪
Optional warmed humidity
probe
▪
▪
▪
▪
Plug-and-play
▪
▪
▪
Weather-proof housing IP66
▪
Applications: meteorological
applications, aviation and road
weather, instrumentation
Chemical purge
USB connection for service use
Installation kits for DTR13 and
DTR502 radiation shields and
also for a Stevenson screen
New, fast temperature probe
Different output possibilities:
voltage, RS-485, resistive Pt100
Long lifetime
Protecting the sensor from scattered
and direct solar radiation, and
precipitation will increase its lifetime.
Thus, Vaisala recommends installing
the HMP155 in one of the following
radiation shields: DTR503, DTR13, or
a Stevenson screen.
Easy maintenance
The probe can be calibrated using a
pc with a USB cable, with the push
buttons, or with the MI70 indicator.
Measurement range
Accuracy (incl. non-linearity, hysteresis
and repeatability) at
+15 ... +25 °C (+59 ... +77 °F)
0 ... 100 %RH
±1 %RH (0 ... 90 %RH)
±1.7 %RH (90 ... 100 %RH)
-20 ... +40 °C (-4 ... 104 °F)
±(1.0 + 0.008 x reading) %RH
-40 ... -20 °C (-40 ... -4 °F)
±(1.2 + 0.012 x reading) %RH
+40 ... +60 °C (+104 ... +140 °F)
±(1.2 + 0.012 x reading) %RH
-60 ... -40 °C (-76 ... -40 °F)
±(1.4 + 0.032 x reading) %RH
Factory calibration
±0.6 %RH (0 ... 40 %RH)*
uncertainty (+20 °C /+68 °F)
±1.0 %RH (40 ... 97 %RH)*
* Defined as ±2 standard deviation limits. Small variations possible,
see also calibration certificate.
Recommended humidity sensor
HUMICAP®180R(C)
Response time at +20 °C in still air with
a sintered PTFE filter
63 %
20 s
90 %
60 s
TEMPERATURE
Measurement range
-80 ... +60 °C (-112 ... +140 °F)
Accuracy with voltage output at
-80 ... +20 °C
±(0.226 - 0.0028 x temperature) °C
+20 ... +60 °C
±(0.055 + 0.0057 x temperature) °C
passive (resistive) output
according to IEC 751
±(0.1 + 0.00167 x |temperature|)°C
1/3 Class B
RS485 output
-80 ... +20 °C
±(0.176 - 0.0028 x temperature) °C
+20 ... +60 °C
±(0.07 + 0.0025 x temperature) °C
Accuracy over temperature range (opposite)
Temperature sensor
Pt100 RTD 1/3 Class B IEC 751
Response time with additional temperature
probe in 3 m/s air flow
63 %
<20 s
90 %
<35 s
OTHER VARIABLES
Operating temperature range
Storage temperature range
Connection
Connection cables
Cable material
Wire size
Service cables
-80 ... +60 °C (-112 ... +140 °F)
-80 ... +60 °C (-112 ... +140 °F)
8-pin male M12 connector
3.5, 10, and 30 m
PUR
AWG26
USB connection cable
MI70 connection cable
Additional T probe cable length
2m
Housing material
PC
Housing classification
IP66
Sensor protection
sintered PTFE
Weigth (probe)
86 g
Electromagnetic compatibility: Complies with the EMC standard
EN61326-1, Electrical equipment for measurement control and
laboratory use - EMC requirement for use in industrial locations
Inputs and outputs
Operating voltage
7 ... 28 VDC*
*Note: minimum operating voltage 12 V with 0 ... 5 V output
and 16 V with 0 ... 10 V output, probe heating, chemical purge or
XHEAT.
Outputs
voltage output
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
resistive Pt100 (4-wire connection)
RS485
Average current consumption
(+15 VDC, load 100 kOhm)
0 ... 1 V output
<3 mA
0 ... 10 V output
+0.5 mA
RS485
<4 mA
during chemical purge
max. 110 mA
with warmed probe
max. 150 mA
Settling time at power-up
voltage output
2s
RS485
3s
ǻ ºC
0.5
dewpoint/frost point temperature,
wet bulb temperature, mixing ratio
0.4
0.3
0.2
0.1
ºC
0
-0.1
-0.2
-0.3
-0.4
-0.5
-80
-60
-40
-20
RS485 output
Measuring humidity reliably is
challenging in environments
where humidity is near saturation.
Measurements may be corrupted
by fog, mist, rain, and heavy dew. A
wet probe may not give an accurate
measurement in the ambient air.
56
For more information, visit
www.vaisala.com or contact
us at [email protected]
0
20
40
60
voltage output
Ref. B210752EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
57
www.vaisala.com
DTR500 Solar Radiation and
Precipitation Shields
The special plastic used in the plates
has excellent thermal characteristics;
the white outer surface reflects
radiation; the black inside absorbs
accumulated heat. The shields can
be easily installed on either a vertical
pole, horizontal beam, or a flat
surface.
Dimensions in mm.
DTR502B
for HMT337, HMT100 and PTU300
DTR503A
for HMP155
(ø105)
(ø105)
r 7BJTBMB)6.*$"1® Humidity and
Temperature Probe HMP155
r7BJTBMB)6.*$"1® Humidity and
Temperature Transmitter HMT337
Choice of models and
installation accessories
(266)
r7BJTBMB)6.*$"1® Humidity and
Temperature Transmitter HMT100
(437)
The maintenance-free DTR500 series
shields protect the humidity and
temperature sensors from solar
radiation and precipitation. They
provide excellent ventilation while
blocking both direct and reflected
solar radiation.
Dimensions
Dimensions in mm.
(200)
Shield protects sensor
The DTR Shields can be used with
the following Vaisala probes:
Dimensions
(361)
The Vaisala Radiation Shield
Series DTR500 are solar radiation
and precipitation shields support
humidity probe installations in
outdoor applications.
Technical data
Two models are available:
r/JOFQMBUFTIJFME
Vaisala Radiation Shield DTR502B
for HMT337, HMT100, PTU300 and
HMP155's additional T probe
(213)
r5XFMWFQMBUFTIJFME
Vaisala Radiation Shield DTR503A
for HMP155
DTR502B pole mast installation.
(233)
DTR503A pole mast installation.
The Vaisala Solar Radiation Shield
Series DTR500 are available in either
a 9 or 12-plate, model.
Features/Benefits
▪
Protects temperature and
humidity probes from
scattered, as well as, direct
solar radiation and rain.
▪
Installs easily on a vertical
pole, horizontal beam or flat
surface
▪
Maintenance-free
▪
Suitable for a wide range of
applications
▪
Naturally ventilated
▪
Choice of shields and
mounting accessories
58
DTR502B horizontal
beam installation.
DTR503A horizontal
beam installation.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210906EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
59
HMD60UO/YO Outdoor Humidity and
Temperature Transmitter & Solar Radiation Shield
Features/Benefits
▪
Vaisala Solar Radiation Shield
DTR503B provides excellent
ventilation while blocking
direct and reflected solar
radiation, and precipitation
True two-wire transmitter with
4 to 20 mA loop powered
output: compatible with most
energy management systems
▪
Electromagnetically
compatible
▪
▪
▪
Temperature compensated
®
Vaisala HUMICAP Humidity and
Temperature Transmitter HMD60YO,
combined with Vaisala Solar Radiation
Shield DTR503B is easy to install and
ideal for outdoor applications.
Full 0 … 100 %RH measurement
Excellent long-term stability
General
Temperature (Y and T models only)
Supply voltage
10 ... 35 VDC (RL = 0 ohms)
20 ... 35 VDC (RL = 500 ohms)
4 ... 20 mA
Output signal
Operating temperature range
electronics
sensor head
Storage temperature range
Connections
Housing
sensor head
electronics housing
Sensor protection
optional
Operating range
-40 … +60 °C (-40 … +140 °F)
s#
0.8
0.6
0.4
-40 … +60 °C (-40 … +140 °F)
-40 … +60 °C (-40 … +140 °F)
-40 ... +80 °C (-40 ... +176 °F)
screw terminals 0.5 ... 1.5 mm2
0.2
0
-20
-10
0
10
Stable performance
in demanding outside
environments
The duct-mount Vaisala HUMICAP®
Humidity and Temperature
Transmitters HMD60UO and
HMD60YO utilize Vaisala HUMICAP®
Sensor. The Vaisala HUMICAP® Sensor
is known for its excellent reliability,
long-term stability, and reliable
operation in humidity measurement.
In addition, the sensors are insensitive
to dust and most chemicals, and
are not damaged by condensation.
The transmitters feature two wire
connections that make retrofitting,
upgrading and installations easy.
Fast, on-site calibration
The accuracy of the transmitters
is easy to check by using Vaisala
HUMICAP® Hand-Held Humidity Meter
60
Shield protects sensor
The maintenance-free, 12 plate
Vaisala Solar radiation Shield
DTR503B is naturally ventilated, and
protects the sensors from scattered,
as well as, direct solar radiation and
rain.
The plates are composed of a special
plastic material that offers excellent
thermal characteristics and UV
stabilized construction. The white
outer surface reflects radiation, while
the black inside absorbs accumulated
heat, resulting in more accurate
measurement.
30
40
50
60
70
80 s#
-0.4
-0.6
-0.8
stainless steel
cast aluminum
membrane filter
stainless steel sintered filter
Relative humidity
Output signal
Accuracy
Linearity
Sensor
-40 … +60 °C (-40 … +140 °F)
better than 0.1 °C (0.18 °F)
PT 1000 IEC 751 class B
Dimensions
HMD60U AND HMD60Y
Dimensions in mm
Measurement range
Accuracy at +20 °C (+68 °F)
0 ... 100 %RH
(ø105)
DTR503B dimensions
%RH
3
2
1
Negligible temperature
coefficient
▪
±2 % accuracy (0...90 %RH),
±3 % (90 % ... 100 %RH)
▪
NEMA 4 (IP65) housing
0
-1
0
10
20
30
40
50
60
70
80
90
100 %RH
-2
-3
Pole Mast, diameter
30...60 mm / 1,2...2,3"
Temperature dependence
Response time at +20 °C (+68 °F)
Sensor
15 s with membrane filter
HUMICAP® 180
(285.5)
%RH
HM70. The calibration can be done in
seconds with a single potentiometer
– without disturbing the operation,
thus ensuring accuracy and saving
hours of maintenance time.
20
-0.2
(442)
▪
▪
Technical data
(266)
www.vaisala.com
Easy-to-install
The easy-to-install DTR503B is
suitable for a wide range of
applications. It can be mounted on a
vertical pole, horizontal beam or flat
surface.
HMD70UO/YO
Versatile alternatives to the
HMD60UO/YO transmitters for
outdoor applications are the
HMD70UO/YO transmitters. These
instruments feature selectable output
signals of 0 … 1V, 0 … 5V, or 0 … 10V
or 0 … 20mA. Powered by either AC
or DC voltage, they are available with
relative humidity only, or relative
humidity and temperature sensors.
They are also equipped with the
radiation/precipitation shield.
2pcs
2.0
1.5
DTR503B pole
installation
1.0
0.5
0
-0.5
-20
0
20
40
60
80 •C
-1.0
-1.5
-2.0
HUMICAP® is a registered trademark of Vaisala.
DTR503B horizontal beam
installation
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210768EN-B ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
61
www.vaisala.com
Technical data
HMT330MIK Meteorological Installation Kit
Dimensions
Dimensions in mm (inches)
13
SFHVMBSQSPCF
XBSNFEQSPCF
After a period of 100 % relative humidity,
the warmed probe measures the true
humidity, whereas the non-warmed
probe takes time to recover from the
condensation.
The HMT337 and PTU307 feature warmed probe technology. Installed with the
HMT330MIK kit either one forms the right choice for reliable humidity measurement
in humid weather conditions.
Features/Benefits
▪
For outdoor humidity and
temperature measurements
▪
Can be ordered in a variety of
configurations
▪
Used together with HMT337
transmitter or PTU307
▪
Vaisala SPH 10/20 Static
Pressure Head eliminates
effectively pressure variations
in the barometer caused by
wind
HMT337/PTU307 Features
▪
Warmed probe provides
truehumidity readings in
condensing conditions
▪
Humidity measurement
expressed as relative humidity
and/or dewpoint temperature
▪
Easy field calibration with the
HM70 hand-held meter
62
The Vaisala Meteorological
Installation Kit HMT330MIK enables
the Vaisala HUMICAP® Humidity
and Temperature Transmitter
HMT337 to be installed outdoors to
obtain reliable measurements for
meteorological purposes.
True humidity readings in
condensing conditions
In weather observations dew
formation makes reliable humidity
measurement difficult. When dew has
formed on the humidity sensor, it is
impossible to obtain a true reading
until this dew evaporates.
Both the PTU307 and HMT337 avoid
this problem by warming the probe.
When warmed, the relative humidity
inside the probe stays below the
ambient level. With an accurate
temperature measurement, the
ambient dewpoint can be calculated
precisely. To obtain the ambient
relative humidity, an additional probe
measures the ambient temperature,
and the transmitter calculates the
relative humidity from the dewpoint
and temperature values.
Open shield prevents
microclimates
The warmed probe of the HMT337/
PTU307 is mounted in a shield which
is open at the bottom to ensure steady
air circulation to the sensor even in
calm weather.
In traditional radiation shields sleet
or snow can accumulate on the shield
and prevent the proper air circulation
through the shield, and create a humid
microclimate until the snow melts.
Essential for critical
weather measurements
Obtaining a true humidity reading is
particularly important e.g. in traffic
safety: at airports and at sea as well
as on the roads. It is essential, for
example, in fog and frost prediction.
d
d
Order form
/++*,.,-%&"'!#*,1,("!!+,*"
/++*,.,)!,!&.&*)-%&"'!#*,
!!&.&*)'+,*"*,#*,
)*)1,("!*,!+,*"
/++*,.,(*/).&)$+'."
!!&.&*)'.,)-(&..",(*/).&)$+'."
..& ,"--/,""!
! "
%!! "$"$"#$$" %$!$# "&"!" ! %!! "$"&$
# "!" %!! "$"&$# "!" %!! "$"&$
# " &" "!" %!! "$"&$# " &" "!" ! %$!$ "#%!! "$""#
! "#$$" %$!$ "#%!! "$"##'
"#$$" %$!$ "! ##'
!
$$"##%"
HUMICAP® is a registered trademark of Vaisala.
For more information, visit
www.vaisala.com or contact
us at [email protected]
For calibration, a portable HMP77
reference probe is easy to attach beside
the HMT337 or PTU307 probe.
Ref. B210944EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
63
HMT300TMK Turbine Mounting Kit for Power
Turbine Intake Air Measurement
cause errors in measurement. The
patented warmed probe prevents
condensation from forming on the
sensor.
Technical data
Dewpoint temperature
General
Measurement range
-40 ... +100 °C (-40 … +212 °F)
Accuracy: find the intersection of the dewpoint temperature
curve and the dewpoint difference reading (process temperature
- dewpoint temperature) on the x-axis and read the accuracy in
dewpoint measurement at the y-axis
screw terminals for 0.5 mm2 wires (AWG 20),
stranded wires recommended
Operating voltage
24 VDC/VAC (20...28 V) or 115/230 VAC
(Must be specified at time of order)
Recommended external load for current outputs
< 500 ohm
0...1 V output
> 2 kohm (to ground)
0...5 & 0...10 V outputs
> 10 kohm (to ground)
Operating temperature range for
electronics
-40...+60 °C (-40 ... +140 °F)
Storage temperature
-55...+80 °C (-67 ... +176 °F)
Housing material
G-AlSi10 (DIN 1725)
Housing classification
IP65 (NEMA 4)
Bushing
8...11 mm diameter cables
(0.31 ... 0.43 inch)
Humidity sensor protection (Ø 12 mm) PPS grid with steel netting
Electromagnetic compatibility
Complies with EMC standard
EN61326-1, Industrial Environment
www.vaisala.com
Features/Benefits
▪
Designed for high humidity
applications
▪
Measurement range:
-40 ... +100°C
▪
▪
Patented, warmed probe
Incorporates Vaisala HUMICAP®
Sensor for excellent accuracy
and long-term stability and
resistance to dust and most
chemicals
▪
▪
Low maintenance need
▪
NIST traceable
(certificate included)
64
Outer cover provides
protection from rain and
direct sunlight
Low maintenance
Power turbines also require exact
water vapor injection in the chamber
to reduce pollutant emissions.
Vaisala’s warmed probe technology
is ideal because of its reliability in
the field. In fact, the only suggested
scheduled maintenance is annual
calibration.
Patented, warmed probe
prevents condensation
The HMT300TMK with the HMT337
installed, provides fast and reliable
dewpoint measurement especially
under high humidity conditions
where dew would normally form on
the humidity sensor and thereby
Dimensions
Dimensions in mm (inches)
Typical accuracy of analog output
at +20 °C (+68 °F)
Typical temperature dependence
of analog output
Serial output available
0...20 mA, 4...20 mA,
0 ... 1 V, 0...5 V, 0 ... 10 V
±0.05 % full scale
±0.005 %/°C full scale
RS232C (optional RS485)
254 (10)
The HMT300TMK can be ordered
separately for installation with the
customer’s existing HMT337.
91.5 (3.6)
203 (8)
.51)
165.3 (6.51)
Ø 13 (0
HUMICAP® performance
The HMT330 Series Transmitters are
fitted with the latest generation of
the HUMICAP®, the polymer sensor
known for its accuracy, reliability and
long-term stability. The sensor has a
high tolerance for particulate abrasion
and chemical contamination.
Two standard outputs, third optional
20 s
HUMICAP® 180C
101.6 (4)
193 (7.6)
488 (19.21)
It is ideal for measuring in water
vapor injection applications because
the sensor has been optimized for
high humidity environments by
utilizing a patented, warmed probe.
Water vapor is added to the intake of
the turbine to increase the mass flow
which in turn increases compression
and electrical power output.
Outputs
100 (3.94)
The Vaisala HUMICAP Turbine
Mounting Kit HMT300TMK is
developed to monitor the air intake of
gas and liquid fueled power turbines.
Response time (90 %) at +20 °C (68 °F)
in still air (PPS grid with steel netting)
Sensor
144.5 (5.69)
®
441.5 (17.38)
The Vaisala HUMICAP® Turbine Mounting Kit HMT300TMK is shown with the cover
open.
The outer cover protects the
transmitter from direct sun light and
rain. The installation kit protects the
probe from outer water splashes,
keeps the sensor dry, and prevents
any parts that could vibrate loose
from entering the turbine.
The HMT300TMK includes a white,
painted aluminum enclosure with
an installation kit for the probe. The
HMT337 Humidity and Temperature
Transmitter is installed in the
aluminum enclosure at the factory.
The instrument can be equipped to
be powered with either 24 VDC/VAC
or with an internal 110/230 volt power
supply unit.
Protective enclosure
Connections
100 (3.94)
354.9 (13.97)
Vaisala HUMICAP®
Humidity and Temperature
Transmitter HMT337
The HMT337 is intended for
demanding industrial humidity
measurement applications with a
risk of condensation. The stainless
steel probe is mechanically durable
and preferred for most industrial
applications.
HUMICAP® is a registered trademark of Vaisala.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210680EN-B ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
65
www.vaisala.com
Vaisala INTERCAP® Humidity and Temperature
Transmitter Series HMW80
The HMW80 combines excellent stability with easy installation and reliable operation.
Features/Benefits
▪
Cost-efficient, dependable
solution for humidity and
temperature measurement for
heating and ventilation
▪
Measurement range
0 ... 100 %RH and -5 ... +55 ˚C
▪
▪
Stable and dependable
▪
▪
▪
▪
Fits EU/US/JPN junction boxes
Combines excellent stability
with easy installation and
reliable operation
2-year warranty
No recalibration required
UL-V0 approved materials
used
The two- and three-wire Vaisala
INTERCAP® Humidity and
Temperature Transmitter Series
HMW80 is designed for use in energy
management systems in buildings.
They combine excellent stability with
reliable operation. The HMW80 is
easy to install: wire it to the terminal
block at the transmitter bottom and
close the housing with a snap-on lid
to cover the electronics.
Low Maintenance Costs
The HMW80 humidity transmitters
use the Vaisala INTERCAP® Sensor
– an interchangeable capacitive
humidity sensor. The transmitters
require no recalibration if the sensor
is changed. This means great savings
in overall maintenance costs. The
sensor is also insensitive to dust as
well as to most chemicals.
Measures Both Humidity
and Temperature
The HMW80 transmitters are
available in four models: HMW82
and HMW83 transmitters measure
both humidity and temperature.
They measure humidity with a
±3 %RH accuracy and with a stability
of ±3 %RH over 5 years. The
accuracy of the temperature
measurement is ±0.5 °C. Two other
models, TMW82 and TMW83,
measure temperature only.
Both 2- and 3-wire transmitters
are also available: HMW82 and
TMW82 are 2-wire (4 … 20 mA loop
powered) transmitters, and HMW83
and TMW83 are 3-wire (0 … 10 V)
transmitters.
Technical Data
Performance
Inputs and outputs
Relative humidity
Measurement range
Accuracy
Temperature range
30 ... 70 %RH
Temperature range
0 ... 100 %RH
Stability
Humidity sensor
HMW82, TMW82
0 ... 100 %RH
10 ... 30 °C
±3 %RH
0 ... 30 %RH, 70 ... 100 %RH ±5 %RH
-5 ... +10 °C, +30 ... + 55 °C
±7 %RH
±3 %RH / 5 years
Vaisala Intercap®
Temperature
Measurement range
Accuracy
+10 ... +30 °C
-5 ... +10 °C, +30 ... +55 °C
Temperature sensor
-5 ... +55 °C
±0.5 °C
±1.0 °C
Digital temperature sensor
Outputs
Loop resistance
Supply voltage
4 ... 20mA, loop powered
0 ... 500 Ohm
10 ... 28 VDC
HMW83, TMW83
Outputs
Load resistance
Supply voltage
0 ... 10V
10 kohm min
15 ... 35 VDC / 24 VAC ±20 %
Mechanics
IP class
Housing colour
Housing material
IP30
RAL9003
ABS/PC
UL-V0 approved
Dimensions
Operating environment
Operating temperature range
Storage temperature range
Electromagnetic compliance
-5 ... +55 °C
-40 ... +60 °C
complies with EMC
standard EN61326-1,
Light industrial Environment
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B211060EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
www.vaisala.com
HMD42/53 Humidity and Temperature
Transmitters for Ducts in Commercial
HVAC Applications
Features/Benefits
The duct mounted Vaisala INTERCAP®
Humidity and Temperature
Transmitters HMD42 and HMD53 are
designed for building automation
applications. They combine reliable
operation with excellent stability,
providing low cost of ownership to
the user.
Flexibility in Humidity
and Temperature
Measurement
The HMD42/53 transmitters measure
humidity with a ±3 %RH accuracy and
temperature with a ±0.4 °C (±0.72 °F)
accuracy. They feature various
selectable analog output signals and
they can be powered by either AC or
DC voltage.
▪
Designed for building
automation applications
▪
▪
±3 %RH accuracy
▪
-20 ... +60 °C (-4 ... +140 °F)
operating range
▪
▪
IP65 (NEMA 4) metal housing
▪
Fully interchangeable Vaisala
INTERCAP® Sensor
▪
Variety of analog signal
outputs available
Full 0 ... 100 %RH measurement
range
Excellent stability and high
reliability
Easy Maintenance
Typical Applications
The HMD42/53 humidity transmitters
use Vaisala INTERCAP® Sensor - the
interchangeable capacitive humidity
sensor. The transmitters require no
recalibration if the sensor is changed.
This means great savings in overall
maintenance costs.
▪
▪
▪
▪
▪
▪
▪
▪
Reliable Performance in
Harsh Environments
The duct mount HMD42/53
transmitters can be installed in
various measurement environments
due to the robust IP65 (NEMA4) rated
metal enclosure, which protects the
sensor from dust and splashes of
water. The wide measurement
temperature range from -20 °C to
+60 °C (-4 ... +140 °F) covers most
HVAC applications.
Office buildings
Retail spaces
Governmental buildings
Educational facilities
Sport and event complexes
Hotels and conference centers
Airports
Metro stations
Technical Data
Relative Humidity
General
Measurement range
Typical accuracy
Temperature range
0 ... 90 %RH
90 ... 100 %RH
Temperature range
0 ... 100 %RH
0 ... +40 °C (+32 ... +104 °F)
±3 %RH
±5 %RH
-20 ... 0 °C, +40 ... +60 °C
(-4 ... +32 °F, +104 ... +140 °F)
0 ... 90 %RH
±5 %RH
90 ... 100 %RH
±7 %RH
Humidity sensor
Vaisala INTERCAP®
Stability
±2 %RH / 2 years
Response time at 20 °C (+68 °F), 90 % response
15 s
Temperature
Measurement range
Output scale
Accuracy
0 ... +40 °C (+32 ... +104 °F)
-20 ... 0 °C, +40 ... +60 °C
(-4 ... +32 °F, +104 ... +140 °F)
Sensor
-20 ... +60 °C (-4 ... +140 °F)
-40 ... +60 °C (-40 ... +140 °F)
±0.4 °C (±0.72 °F)
±0.6 °C (±1.1 °F)
Pt1000 IEC 751 Class B
General - HMD42
Supply voltage
10 ... 35 VDC (RL = 0 ohm)
20 ... 35 VDC (RL = 500 ohm)
4 ... 20mA
Output signal
General - HMD53
Operating temperature range
electronics
-5 ... +55 °C (+23 ... +131 °F)
probe
-20 ... +60 °C (-4 ... +140 °F)
Storage temperature range
-40 ... +60 °C (-40 ... +140 °F)
Maximum flow speed
50 m/s
Housing material
probe
stainless steel
electronics
cast aluminium
Housing classification
IP65 (NEMA 4)
Connections
screw terminal 0.5 ... 1.5 mm2
Cable thread-through bushing for 7 ... 10 mm
(PG9) included
(18941HM)
Complies with EMC standard EN61326 and EN55022
Accessories
Armoured cable gland
Current module (for HMD53)
10528HM
18945HM
Spare Parts
Vaisala INTERCAP sensor, 1 piece
Vaisala INTERCAP sensor, 10 pcs
Membrane filter
Sintered filter
15778HM
INTERCAPSET-10PCS
DRW010525
HM46670SP
Dimensions
Dimensions in mm
60
250
Supply voltage range depends on the selected output signal
DC
AC
0 … 1V
10 … 35V
9 … 24V
0 … 5V
14 … 35V
12 … 24V
0 … 10V
19 … 35V
16 … 24V
Ø 12
WITH OPTIONAL CURRENT MODULE
82
100
100
0 ... 20 mA (RL= 0 ohm)
10 … 35V
11 … 24V
**0 … 20 mA (RL=500 ohm)
20 … 35V
17 … 24V
Power consumption @ 24VAC
12mA typical
**Optional temperature scales are available on request.
82
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B211140EN-A ©Vaisala 2011
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
Dew Point
www.vaisala.com
the user to monitor measurement
trends and one-year history.
The optional data logger with realtime clock makes it possible to
generate more than four years of
measured history and zoom in on any
desired time or time frame.
The display alarm allows tracking
of any measured parameter, with a
freely configurable low and high limit.
Versatile outputs and
(wireless) data collection
The display shows measurement trends,
real time data and history.
The DMT340 can be connected to a
network with an optional (W)LAN
interface, which enables a (wireless)
Ethernet connection.
For serial interface also the USB
connection, RS232 and RS485 can
be used. Additionally an alarm relay
option is available.
The transmitter can have up to three
analog outputs. Galvanic isolation of
supply power and analog outputs are
also offered.
The recorded measurement data
can be viewed on the display or
transferred to a PC with Microsoft
Windows® software.
Easy installation
The DMT340 has a variety of features
to choose from. Units are delivered
installation-ready.
The Vaisala DRYCAP® HandHeld
Dewpoint Meter DM70 is ideal for field
checking DMT340 transmitters.tt
Probe specifications
Dimensions
DMT342 with Small Size
Flanged Probe
Dimensions in mm (inches)
92.5 (3.64)
Flange intersection
ø12 (0.47)
DMT340 Series Dewpoint and Temperature
Transmitters for very dry conditions
41(1.61)
▪
▪
▪
66
Withstands condensation
Unique auto-calibration feature
Optional alarm relays, local
display and mains power
supply module
Compatible with Vaisala
DRYCAP® Hand-Held Dewpoint
Meter DM70
NIST traceable (certificate
included)
3 analog outputs and a serial
interface, WLAN/LAN
Stability in low dew points
The Vaisala DRYCAP® Sensor is
immune to particulate contamination,
water condensation, oil vapor
and most chemicals. Since the
sensor withstands condensation,
its performance is unmatched for
low dew point applications that
experience water spikes in the
process. The sensor recovers rapidly
from contact with free water.
Patented auto-calibration
The stability of the DMT340 is
due to the unique auto-calibration
function, patented by Vaisala.
Graphical measurement
trend and history display
The DMT340 can be ordered with a
large numerical and graphical display
with a multilingual menu. It allows
Probe diameter
The DMT342 probe is installed using
a flange or sampling cell.The small
probe is ideal for integrating into larger
equipment.
16
9(0.35)
ø36 (1.42)
71.5 (2.81)
12 mm/0.5 inch
58.7 (2.31)
Installation
Flange
36 mm/1.4 inch
Sampling cell
45°
45°
1/8"-27 NPT
ø24
.5
HMP302SC
M
6
71 (2.80)
Probe specifications
Dimensions
DMT344 with Probe for
High Pressures
Dimensions in mm (inches)
Pressure range
0 ... 50 bar/0 ... 725 psia
Mechanical durability
Probe diameter
7 (0.28)
81 (3.19)
Sampling cell HMP302SC
ø32 (1.26)
The DMT344 features a threaded
connection for extended pressures
with different fitting body options. It is
ideal for permanent installations into
pressurized or vacuum processes.
M6
(0
.6
3)
up to 250 bar/
3625 psia
up to 100 bar/
1450 psia
12 mm/0.5 inch
Ø 12 (0.47)
▪
Vaisala DRYCAP® Sensor
provides accurate, reliable
measurement with excellent
long-term stability and fast
response
Mechanical durability
M22x1.5 or
NPT 1/2"
▪
▪
▪
Measures dew points from
-60 °C to +80 °C (-76 ... +176
°F) with the accuracy of ±2 °C
(±3.6 °F)
The auto-calibration makes the
transmitter perform a calibration
and adjustment by itself while the
measured process is running. If
the measurement accuracy is not
confirmed, corrections are made
automatically. The procedure is
so quick and corrections are so
minor that it will go unnoticed.
This ensures low maintenance and
high performance. To continue
performance at the highest level, the
transmitter can be sent to Vaisala
for a NIST traceable calibration.
Calibration intervals depend on the
application; in normal conditions, a
NIST traceable calibration in every
two years is recommended.
ø12.5 (0.49)
▪
The Vaisala DRYCAP® Dewpoint and
Temperature Transmitter Series
DMT340 is designed for industrial
low humidity applications. Typical
applications include compressed air
drying and metal treatment. The
device is very reliable, easy to use
and economical to maintain.
0 ... 50 bar/0 ... 725 psia
1/8"-27 NPT
Features/Benefits
45°
Pressure range
41 (1.61)
120 (4.72)
170 (6.69)
Installation
Fitting Body
M22 x 1.5
Fitting Body
NPT 1/2"
67
Technical data
Probe specifications
Dimensions
Measured parameters
DMT347 with Small Sized Probe
Dimensions in mm (inches)
DEW POINT
up to 100 bar/
145 psia
12 mm/0.5 inch
Installation
The DMT347 probe is ideal for tight
spaces with thread connection.The
small probe is installed using the
Swagelok® connectors.
Fitting Body
R 3/8" ISO
Fitting Body
G 1/2" ISO
Fitting Body
NPT 1/2"
(EXMM
Probe specifications
Dimensions
DMT348 with Probe for
Pipeline Installations
Dimensions in mm (inches)
Pressure range
Adjustable length
20 ... 50 bar/290 ... 725 psia
Vaisala DRYCAP®180M
-60 ... +80 °C (-76 ... +176 °F) Td
-60 ... +45 °C (-76 ... +113 °F) Td
±2 °C/±3.6 °F see the accuracy
graph below
additional inaccuracy +1 °C Td
215.5 (8.48) / 448 (17.6)
0 ... 40 bar/0 ... 580 psia
41 ... 149/371 mm/
1.61 ... 5.87/14.6 inch
Fitting Body
NPT 1/2"
Ball Valve Set
BALLVALVE-1
Sampling Cell
DMT242SC or
DMT242SC2
41 (1.61)
R1/2” ISO7/1
R1/2" ISO
Ø 13.5 (0.53)
Fitting Body
191 (7.52) / 410 (16.1)
41 (1.61) - 149 (5.87) / 41 (1.61) - 379 (14.9)
Ø 12 (0.47)
Installation
The DMT348 is ideal for installations
in pressurized processes where the
probe needs to be removed while the
process is running.The probe depth is
adjustable.
) 3 / v . 0 4 v OR' v)3/
Mechanical durability
Probe diameter
0 ... 10 bar/0 ... 145 psia
ΠPressure range
Sensor
Measurement range
For continuous use
Accuracy
up to 20 bar/290 psia
Inputs and outputs
35 (1.37)
Dew point accuracy vs. measurement conditions
Response time
63% [90%] at +20°C gas temperature
Flow rate
1 l/min and 1 bar pressure
-60 ... -20 °C Td (-76 ... -4 °F Td)
5s [10s]
-20 ... -60 °C Td (-4 ... -76 °F Td)
45s [10min]
TEMPERATURE
Measurement range
Accuracy
Temperature sensor
0 ... +80 °C (+32 ... +176 °F)
±0.2 °C at room temperature
Pt 100 IEC 751 1/3 class B
RELATIVE HUMIDITY
Optional filter for low pressures
(for all models)
Measurement range
Accuracy (RH <10 %RH, at + 20 °C)
0 ... 70 %RH
±0.004 %RH + 20 % of reading
PPM
Measurement range (typical)
10 ... 2500 ppm
Accuracy (at + 20 °C, 1 bar)
1 ppm + 20 % of reading
Other measurement parameters available (depends on model)
mixing ratio, absolute humidity, pressure dew point calculated
to 1 bar, temperature difference (T-Td), water vapor pressure
Operating environment
Operating temperature
for probes
-40 ... +80 °C (-40 ... +176 °F)
Mechanical durability
Up to +180 °C (+356 °F)
for transmitter body
-40 ... +60 °C (-40 ... +140 °F)
with display
0 ... +60 °C (+32 ... +140 °F)
Storage temperature range
-55 ... +80 °C (-67 ... +176 °F)
Pressure range for probes
See probe specifications
Sample flow rate
No effect
Measured gases
non corrosive
Complies with EMC standard EN61326-1, Electrical equipment
for measurement, control and laboratory use - EMC requirements;
Industrial environment.
68
Operating voltage
10 ... 35 VDC, 24 VAC
with optional power supply module
100 ... 240 VAC 50/60 Hz
Power consumption @ 20 °C (Uin 24VDC)
RS-232
max 25 mA
max 25 mA
Uout 2 x 0...1V / 0...5V / 0...10V
Iout 2 x 0...20 mA
max 60 mA
display and backlight
+ 20 mA
during sensor purge
+ 110 mA max
Analog outputs (2 standard, 3rd optional)
current output
0 ... 20 mA, 4 ... 20 mA
voltage output
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
Accuracy of analog outputs at 20 °C
0.05 % full scale
Temperature dependence of the
analog outputs
± 0.005 %/°C full scale
External loads
current ouputs
RL < 500 ohm
0 ... 1V output
RL > 2 kohm
0 ... 5V and 0 ... 10V outputs
RL > 10 kohm
Max wire size
0.5 mm2 (AWG 20) stranded wires recommended
Digital outputs
RS-232, RS-485 (optional)
Service connection
RS-232, USB
Relay outputs
0.5 A, 250 VAC, SPDT (optional)
Ethernet interface (optional)
Supported standards
10/100Base-T
Connector
RJ45
Protocols
Telnet
WLAN interface (optional)
Supported standards
802.11b
Antenna connector type
RP-SMA
Protocols
Telnet
Security
WEP 64/128,WPA
Authentication / Encryption
Open / no encryption
Open / WEP
WPA Pre shared key / TKIP
WPA Pre shared key / CCMP (a.k.a. WPA2)
Optional data logger with real-time clock
Logged parameters
max. three with trend/min/max values
Logging interval
10 sec (fixed)
Max. logging period
4 years 5 months
Logged points
13,7 million points per parameter
Battery lifetime
min. 5 years
Display
LCD with backlight, graphic
trend display of any parameter
Display menu languages
English, Chinese, Spanish, German,
French, Japanese, Russian, Swedish,
Finnish
69
Dimensions
Cable bushing M20x1.5 for cable diameter 8 ... 11mm/0.31 ... 0.43”
Conduit fitting
1/2”NPT
User cable connector (optional)
M12 series 8 pin (male)
option 1
with plug (female) with 5 m / 16.4 ft black cable
option 2
with plug (female) with screw terminals
USB-RJ45 Serial Connection Cable
order no. 219685
Probe cable diameter
5.5 mm
Probe cable lengths
2 m, 5 m or 10 m
Housing material
G-AlSi 10 Mg (DIN 1725)
Housing classification
IP 65 (NEMA 4X)
Dimensions in mm (inches)
77 (3.03)
71 (2.80)
Mechanics
183 (7.20)
7 (0.28)
Ø
96 (3.78)
116 (4.57)
169 (6.65)
Ensure dry
compressed air
with dewpoint
measurement
DRYCAP® is a registered trademark of Vaisala.
Vaisala innovated DRYCAP® dewpoint instruments
have been developed for the most demanding
conditions.
▪
▪
▪
▪
Fastest wet-to-dry response time on the
market - just minutes
High resistance to contamination - immune to
compressor oil
Complete recovery from saturated conditions
Long 2-year calibration interval
Want to know more? Our experts welcome your most
difficult questions.
TYPE APPROVED PRODUCT
CERTIFICATE NO.: A-11440
For more information, visit
www.vaisala.com or contact
us at [email protected]
70
Ref. B210952EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
www.vaisala.com/compressedair
[email protected]
71
www.vaisala.com
DMT345 and DMT346 Dewpoint Transmitters
for High Temperature Applications
DMT346, Reliable in very hot processes
trends and up to one-year measurement history.
When process temperatures range between 140 °C to
350 °C, the DMT346 provides the best measurement
performance.
The optional data logger with real-time clock makes it
possible to generate more than four years of the measured
history and zoom in on any desired time or time frame.
The DMT346 comes with a cooling set as a standard
feature. The cooling effect may be regulated by adding the
cooling fins, or removing them from the set for the best
measurement performance.
Versatile outputs and (wireless) data
collection
The cooling system operates without moving parts,
additional power or cooling utilities, thereby eliminating
the risk of sensor damage due to a mechanical cooling
failure.
The large and clear display allows the
user to check data at a glance.
Additionally, sensor warming minimizes the risk of
condensing on the sensor. In low humidity the combination
of auto-calibration and DRYCAP® ensures accurate
measurement.
Graphical display
The Vaisala DRYCAP® Dewpoint Transmitters DMT345 and DMT346 are designed
to measure and control humidity especially in dry environments with high
temperatures.
Features/Benefits
▪
The DMT345 measures
humidity in temperatures up to
180 °C (356 °F)
▪
The DMT346 measures
humidity in temperatures up to
350 °C (+662 °F)
▪
Dewpoint accuracy ±2 °C
(±3.6 °F)
▪
Vaisala DRYCAP® Sensor
provides accurate, reliable
measurement with excellent
long-term stability and fast
response
▪
▪
▪
Both transmitters incorporate the
Vaisala DRYCAP® sensor, which is
accurate, reliable, and stable. The
sensor withstands condensation
and is immune to particulate
contamination, oil vapor and most
chemicals. The DRYCAP® sensor
stands out for its swift response time
and rapid recovery after getting wet.
Withstands condensation
Unique auto-calibration feature
Optional local display with
keypad, mains power supply
module and alarm relays
▪
NIST traceable calibration
(certificate included)
▪
Analog outputs, WLAN/LAN
72
The Vaisala DRYCAP® Dewpoint
Transmitters DMT345 and
DMT346 are designed for humidity
measurement in industrial drying
applications with particularly high
temperatures.
Measure humidity directly
in hot processes
The DMT345 and DMT346 are
constructed for direct measurement
in hot processes. Therefore, there
is no need for sampling systems
and trace heating. As a result,
high accuracy and constancy are
maintained.
The accuracy and stability of the
DMT345 and the DMT346 are due to
the unique auto-calibration function,
patented by Vaisala. This autocalibration makes the transmitter
perform a calibration and adjustment
by itself while the measured process
is running. If the measurement
accuracy is not confirmed, corrections
are made automatically. The
procedure is so quick and corrections
are so minor that it will go unnoticed.
This ensures low maintenance
and high performance. In normal
conditions, it is recommended to have
a traceable calibration performed
once a year.
The DMT345 and DMT346 transmitters can be ordered
with a large numerical and graphical display, which allows
the user to clearly monitor operational data, measurement
For serial interface also the USB connection, RS232 and
RS485 can be used. Additionally an alarm relay option is
available.
The transmitter can have up to three analog outputs.
Galvanic isolation of supply power and analog outputs
are also offered. The recorded measurement data can be
viewed on the display or transferred to a PC with Microsoft
Windows® software.
Units are delivered installation-ready and meet ROHS
requirements.
Technical data
Measured variables DMT345
TEMPERATURE DMT345
DEWPOINT DMT345
Sensor
Measurement range
Accuracy
Vaisala DRYCAP®180S
-40 ... +100 °C (-40 ... +212 °F) Td
±2°C (±3.6 °F) Td
See the accuracy graph below
Measurement range
with sensor warming
Accuracy
Temperature sensor
DMT345, Accurate in hot
and dry environments
0 ... +180 °C (+32 ... +356°F)
upper range limited by humidity
(at 80% RH warming is switched on and T
reading not actual process Temperature)
±0.4 °C at 100 °C
Pt 100 IEC 751 1/3 class B
RELATIVE HUMIDITY DMT345
The DMT345 is designed for accurate
humidity measurement in hot and
dry conditions. This model provides
unmatched dry end measurement
accuracy in temperatures up to 140 °C,
however the DMT345 can operate
safely in temperatures up to 180 °C.
The stainless steel probe is especially
designed for high temperatures and
has an optional installation flange that
allows an adjustable installation depth
and therefore a precise positioning.
The transmitter can be connected to a network with an
optional (W)LAN interface, which enables a (wireless)
Ethernet connection.
Measurement range
with sensor warming
Accuracy
below 10 % RH
above 10 % RH
0 ... 100 % RH
0 ... 80 % RH
±10 % of reading
±1,5% RH + 1,5 % of reading
MIXING RATIO DMT345
Dewpoint accuracy vs. measurement conditions
Measurement range (typical)
Accuracy (typical)
0 ... 1000 g/kg (0 ... 7000 gr/lbs)
±12% of reading
Response time 63 % [90 %] flow rate 1 l/min and 1 bar pressure
from dry to wet
5s [10 s]
from wet to dry including auto-calibration
45s [5 min]
73
Technical data
Dimensions
Dimensions in mm (inches)
DMT345 probe and mounting flange
DMT345 and DMT346 Transmitter housing
77 (3.03)
71 (2.80)
DRILLING
183 (7.20)
169 (6.65)
DMT346 Cooling set
304 (11.97)
164 (6.46)
112.5 (4.43)
120 (4.72)
40.6 (1.6)
ø105 (4.13)
ø118 (4.65)
ø28 (1.1)
8 15 (0.59)
(0.31)
ø89 (3.5)
ø20 (0.79)
ø7 (0.28)
96 (3.78)
116 (4.57)
27.5
(1.08)
sintered
filter
(fixed on top of
the cooling set)
125 (4.92)
cooling element
mounting
flange
cooling fins
DMT346 Probe
Stainless steel grid
cable 2,5 or 10 m
357 (14.1)
334.5 (13.17)
ø 11
(0.43)
22.5 (0.89)
ø13.5 (0.53)
DRYCAP® is a registered trademark of Vaisala.
For more information, visit
www.vaisala.com or contact
us at [email protected]
74
Ref. B210723EN-C ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
75
www.vaisala.com
DMT242 Dewpoint Transmitter for
OEM Applications
Technical data
Dewpoint temperature
Operating environment
Measurement range (typical)
-60 ... +60 °C (-76 ... +140 °F)
Analog output scalings
Option A
-80 ...+20 °C (-112 ... +68 °F) Td
Option B
-60 ... +60 °C (-76 ... +140 °F) Td
Option X
free scaling
(when the dewpoint is below 0 °C (32 °F),
the transmitter outputs frostpoint)
Accuracy with DRYCAP® 180M
±2 °C (±3.6 °F)
(see graph below)
Temperature
higher temperature peaks
Relative humidity
Pressure
Sample flow rate
0 ... +60 °C (32 ... +140 °F)
Short-term OK
0 ... 100 %RH
0 ... 20 bara (0 ... 290 psia)
no effect
Output
Analog output
Resolution for analog output
Typical temperature dependence
Serial line for service use
4 ...20 mA
±0.002 mA
0.0008 mA/ °C
RS232
General
Due to its wide measurement range and high long-term stability, the DMT242 is an
ideal choice for low dewpoint industrial applications such as compressed air dryers,
plastic dryers and other OEM applications.
The Vaisala DRYCAP® Hand-Held Dewpoint
Meter DM70 is ideal for confirming the
performance of the DMT242 in the field.
DEWPOINT ACCURACY VS. MEASUREMENT CONDITIONS
▪
▪
▪
▪
▪
▪
▪
▪
76
Ideal choice for industrial dryer
applications
Incorporates advanced Vaisala
DRYCAP® Sensor and enhanced
auto-calibration software
Long-term stability in low
dewpoints
Fast response time
Two sensor options cover
dewpoint measurement range
from -60 … +60 °C
(-76 … +140 °F) with an
accuracy of ±2 °C (±3.6 °F)
Withstands condensation
NIST traceable (certificate
included)
Compatible with Vaisala
DRYCAP® Hand-Held Dewpoint
Meter DM70
Vaisala DRYCAP ®
The Vaisala DRYCAP® Dewpoint
Transmitter DMT242 provides
reliable and stable measurements
for industrial dryer applications. It is
designed for extreme conditions.
DMT242 incorporates the Vaisala
DRYCAP® thin film polymer sensor
and auto-calibration software.
The standard sensor choice for
dry gases and desiccant dryers is
DRYCAP® 180M and for more humid
applications such as refigeration
dryers, a DRYCAP® 180S sensor.
Both the sensors are immune to
particulate contamination, water
condensation, oil vapor and most
chemicals. Because the sensor
withstands condensation, its
performance is unmatched for
low dewpoint applications that
experience process water spikes,
such as pipeline condensation during
a system failure or start-up.
The auto-calibration software works
on-line while the process is running.
If the measurement accuracy is not
confirmed, corrections are made
automatically. The DMT242 adjusts
the measurement, corrects dry-end
drifts and continues to function.
Calibration occurs quickly, and
with corrections so minor, it will go
unnoticed.
Compact, rugged and
intelligent
Due to its compact size, DMT242 is
quickly and easily installed in tight
spaces.
Users can perform a field-check by
using the Vaisala DRYCAP® HandHeld Dewpoint Meter DM70. The
transmitter can be sent to Vaisala
Service for NIST traceable calibration.
The recommended calibration
interval is every two years.
Response time 63 % [90 %] at +20 °C gas temperature
Flow rate >1 l/min and 1 bar pressure
-60 -> -20 °C Td (-76 -> -4 °F Td)
5 s [10 s]
-20 -> -60 °C Td (-4 -> -76 °F Td)
45 s [10 min]
±2 °C (±3.6 °F)
Accuracy with DRYCAP® 180S
(see graph below)
DRYCAP® 180M
DRYCAP® 180S
18 - 35 VDC, 20 - 28 VAC
max. 220 mA
max. 500 Ω
2 m or 10 m
0.75 mm2
6.5 mm /PG7
product code DMT242RS
Probe material (wetted parts)
Dewpoint temperature (°C)
Features/Benefits
Sensor
Optimal sensor for refrigeration dryers
Operating voltage
Power consumption at 24 VDC
External load for analog output
Optional connection cable with
DMT242 connector
Connector for supply voltage and
signal output
max. wire size
max. cable diameter
Service cable for serial interface
RS232
70
60
50
40
30
20
10
0
-10
-20
-30
-40
-50
-60
-70
-80
Water
vapor
satura
e
tion lin
y < ± 2°C
Accurac
Td
it
lower lim
urement range
Dewpoint meas
0
10
20
30
40
50
60
stainless steel
(AISI 316L)
Sensor protection
stainless steel
sintered filter (HM47280)
Mechanical connection
G½” ISO228-1 thread with
bonded seal ring (U-seal)
Eletronics housing material
plastic (ABS/PC)
Housing classification
IP65 (NEMA4)
Storage temperature range
-40 ... +70 °C, (-40 ... +158 °F)
Complies with the EMC standard EN61326-1, Electrical equipment
for measurement, control and laboratory use - EMC requirements;
Industrial environment.
Process temperature (°C)
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210765EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
77
Measured variables
General
DEW POINT TEMPERATURE
Sensor
Dew point temperature (°C)
Measurement range
-80 ... -10 °C (-112 ... +14 °F)Td
Accuracy
±2 °C (3.6 °F) Td
Non-calibrated range
-100 ... +20 °C (-148 ... +68 °F)Td
Analog output scalings
option 1
-80 ... +20 °C (-112 ... +68 °F) Td
option 2
-100 ... 0 °C (-148 ... +32 °F) Td
option 3
user-specified output scaling
when dew point is below 0 °C (32 °F) the transmitter outputs
frost point
Accuracy over temperature range
30
20
10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
-10
Typical accuracy +5 °C Td
Not recommended for continuous measurement
Accuracy +2 °C Td
or better
Accuracy not specified
-30
-20
-10
0
10
20
30
40
50
60
70
Temperature of measured gas (°C)
The small and powerful DMT152 measures dew point down to -80 °C.
Features/Benefits
DMT152
Applications
▪
▪
▪
Compact
▪
Measures dew point down
to -80 °C (-112 °F )
The DMT152 is an ideal choice for
industrial applications where it
is necessary to control very low
humidity. Most typical areas of
use are air and plastics dryers, dry
chambers, pure gases, and
highvoltage circuit breakers.
▪
Reduced maintenance costs
due to long calibration
interval
The Vaisala DRYCAP® Dewpoint
Transmitter DMT152 is designed for
measuring low dewpoint in OEM
applications, even down to -80°C .
The excellent long-term stability and
reliability of its performance is based
on the latest DRYCAP® polymer
sensor technology.
▪
▪
▪
▪
Fast response time
Accurate
Vaisala DRYCAP® technology
with a polymer sensor
Withstands condensation
NIST traceable
Applications: compressed air,
plastics drying, dry chambers,
pure gases, and high-voltage
circuit breakers
Low maintenance
The DMT152 mechanics have been
designed for harsh environments
requiring protection against dust,
dirt, and splashed water.
The DRYCAP® technology has a low
maintenance need due to its excellent
long-term stability and durability
against condensation.
The DMT152 measures accurately
and reliably also in the challenging
combination of low humidity and
hot air, which is typical in plastics
drying.
Response time 63 % [90 %] at a gas temperature of +20 °C (+68 °F)
and pressure of 1 bar
-10 ... -80 °CTd
0.5 min [7.5 min]
-80 ... -10 °CTd
2 s [5 s]
PPM VOLUME CONCENTRATION
Measurement range (typical)
Accuracy at +20 °C (+68 °F),
1013 mbar
0 ... 500 ppm
Accessories
±(0.2 ppm + 20 % of reading)
Operating environment
Temperature
Relative humidity
Pressure
Measured gases
Sample flow rate
-40 ... +70 °C (-40 ... +158 °F)
0 ... 100 %RH (up to + 20 °C/68 °F)
0 ... 50 bar (725 psia)
non-corrosive gases
no effect on measurement accuracy
Connection cable for MI70 hand-held indicator
USB cable for pc connection
Sampling cells (available for ISO G½”)
basic sampling cell
with Swagelok 1/4” male connectors
with a quick connector and leak screw
two-pressure sampling cell
NW40 flange
Outputs
Two analog outputs (scalable)
4 ... 20 mA, 0 ... 20 mA (3 wire)
0 ... 5 V, 0 ... 10 V
Accuracy of analog outputs
± 0.01 V / ±0.01 mA
Digital output
RS485 (2-wire)
Alarm-level indication by analog signal
user selectable
Purge information
5 V, 10 V, 20 mA or LED
For more information, visit
www.vaisala.com or contact
us at [email protected]
78
Vaisala DRYCAP® 180U
Thin-film capacitive polymer sensor
Recommended calibration interval
2 years
Operating voltage with
RS485 output
11* ... 28 VDC
voltage output
15* ... 28 VDC
current output
21 ... 28 VDC
*For extended temp. down to -40 °C (-40 °F) or pressure up to
50 bar (725 psia), the supply voltage is 21 ... 28 VDC.
Supply current
normal measurement
20 mA + load current
during self-diagnostics
max. 220 mA pulsed
Supply voltage fluctuation
max. 0.3 V
External load for
voltage output
min. 10 kOhm
current output
max. 500 Ohm
Housing material (wetted parts)
AISI316L
Stainless steel mesh filter
AISI303, filter grade 18 μm
ISO G½”, NPT ½", UNF 3/4”- 16”
Mechanical connections
Housing classification
IP65 (NEMA 4)
Storage temperature range
-40 ... +80 °C (-40 ... +176 °F)
Weight (ISO G½”)
190 g (6.70 oz)
Complies with EMC standard EN61326-1, Electrical equipment for
measurement control and laboratory use - EMC requirements;
Industrial environment
2.99
76
4.74
120.5
219980
219690
DMT242SC
DMT242SC2
DSC74
DSC74B
225220SP
1.3 3
Ø3
1.28
32.5
0.47
Ø 12
DMT152 Dewpoint Transmitter for Low
Dew point Measurement in OEM Applications
Technical data
1.16
Ø 29.5
www.vaisala.com
1.18
AW 30
G 1/2" ISO 228-1
Ref. B210750EN-C ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
79
www.vaisala.com
DMT142 Miniature Dewpoint Transmitter
for OEM Applications
Technical data
Measured variables
DEW POINT TEMPERATURE
Measurement range(typical)
Standard version
-40 ... +60 °C (-40 ... +140 °F) Td
Extended version
-60 ... +60 °C (-76 ... +140 °F) Td
SF6 version
-50 ... +60 °C (-58 ... +140 °F) Td
Analog output scalings
option 1
-80 ...+20 °C (-112 ... +68 °F) Td
option 2
-60 ... +40 °C (-76 ... +104 °F) Td
option 3
free scaling
Accuracy
±3 °C (±5.4 F) Td (see graph below)
(when the dew point is below 0 °C (32 °F), the transmitter outputs
frostpoint)
The Vaisala DRYCAP® Dewpoint Transmitter DMT142 is an ideal choice for
small compressed air dryers, plastic dryers and other OEM applications.
The Vaisala DRYCAP® Hand-Held
Dewpoint Meter DM70 is ideal for
confirming the performance of the
DMT142 in the field.
Features/Benefits
Vaisala DRYCAP®
Long calibration interval
▪
The Vaisala DRYCAP® Dewpoint
Transmitter DMT142 is a miniature
dew point measurement instrument.
The transmitter can be installed
directly into pressurized systems at
50 bar (725 psia) maximum pressure.
The long-term high performance
is achieved with Vaisala DRYCAP®
technology.
The calibration interval of the
DMT142 is two years. Additionally,
the Vaisala DRYCAP® Hand-Held
Dewpoint Meter DM70 can be used
to confirm the performance of the
DMT142 without disconnecting the
transmitter. For any adjustment
needs, the transmitter can be sent to
Vaisala Service.
The sensor fully withstands getting
wet, and therefore, the transmitter
performs exceptionally well in
applications that occasionally
experience process water spikes,
such as pipeline condensation during
a system failure or start-up. The
sensor is also immune to particulate
contamination, oil vapor and most
chemicals, and is insensitive to the
flow rate.
The auto-calibration software works
on-line while the process is running.
If the measurement accuracy is not
confirmed, corrections are made
automatically.
▪
▪
▪
▪
▪
▪
▪
80
Miniature size dew point
transmitter for e.g. small
industrial dryer applications
Vaisala DRYCAP® technology
with auto-calibration
Calibration interval of two years
Dew point measurement range
-60 ... +60 °C (-76 ... +140 °F)
with an accuracy ±3 °C (±5.4°F)
Withstands condensation
Fast response time
Compatible with Vaisala
DRYCAP® Hand-Held Dewpoint
Meter DM70
NIST traceable (certificate
included)
Easy installation
The DMT142 has a variety of features
to choose from, including different
output and installation options. Due
to its small size and light weight,
the DMT142 is quickly and easily
installed in tight spaces or in smallsize pipelines.
DEW POINT ACCURACY VS. MEASUREMENT CONDITIONS
Dew point accuracy range for the extended version. Standard
version with dotted line.
Response time 63% [90%] at +20 °C gas temperature and 1 bar
pressure
-60 -> -20 °C Td (-76 -> -4 °F Td)
5 s [10 s]
45 s [10 min]
-20 -> -60 °C Td (-4 -> -76 °F Td)
PPM VOLUME CONCENTRATION
Measurement range
70 ... 200 000 ppm
Accuracy at +20 °C (+68 °F), 1013 mbar 7.3 ppm + 9.2% of reading
Operating environment
Temperature *)
-40 ... +60 °C (-40 ... +140 °F)
Relative humidity
0 ... 100 %RH
Pressure *)
0 ... 50 bara (725 psia)
Sample flow rate
no effect for measurement accuracy
*) For extended temperature down to -40 °C (-40 °F) or pressure up
to 50 bara (725 psia) the supply voltage must be 24 ... 28 VDC.
Outputs
Analog output (scalable)
4 ... 20 mA (3-wire), 0 ... 1 V/5 V
Resolution for current output
0.002 mA
Resolution for voltage output
0.3 mV
Typical temperature dependence
0.005% of span / °C
Connector
4-pin M8 (IEC 60947-5-2)
connection cable with snap-on or thread locking available
RS232 serial line for service use
with DMT142RS cable
General
Sensor
Measured gases
Vaisala DRYCAP® 180D
non-corrosive gases
(SF6 gas with special model)
Recommended calibration interval
to confirm the specified accuracy
2 years
Operating voltage with voltage output
12 ... 28 VDC
Operating voltage with current output
18 ... 28 VDC
Supply current
normal measurement
10 mA + load current
during self-diagnostics
max. 220 mA pulsed
Load for current output
max. 500 ohm
Load for voltage output
min. 10 kohm
Housing material
stainless steel body (AISI316L)
plastic cap(ABS/PC)
Sensor protection
stainless steel sintered filter
Mechanical connection
G1/2” ISO 228-1 thread
with bonded seal ring
(U-seal)
Housing classification
IP64 (NEMA 3S)
Storage temperature range
-40 ... +80 °C (-40 ... +176 °F)
Weight
118 g (4.16 oz)
Complies with EMC standard EN61326-1, Electrical equipment
for measurement, control and laboratory use - EMC requirements;
Industrial environment.
Accessories
Output cable M8, snap-on connector, 2 meters
211598
Output cable M8, thread connector, 3 meters HMP50Z300, several
lengths available
Connection cable for DM70
211917ZZ
Service cable for serial line
DMT142RS
Sampling cells
basic sampling cell
DMT242SC
with Swagelok 1/4" male connectors
DMT242SC2
with quick connector and leak screw
DSC74
two-pressure sampling cell
DSC74B
cooling/venting coil
DMCOIL
See DM70 / Portable Sampling Systems and Sampling Cells for
further information about sampling cells available
Ref. B210375EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
81
www.vaisala.com
DM70 Hand-Held Dewpoint Meter
for Spot-Checking Applications
Technical data
TEMPERATURE
The Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70
offers accurate and fast measurement for industrial dew point
applications, such as compressed air, metal treatment and
plastics drying.
response from ambient to dry conditions exceptionally
fast.
The DM70 is fitted with the Vaisala DRYCAP® Sensor. The
sensor provides reliable, stable and high-performance
dew point measurement. Autocalibration detects on-line
possible measurement inaccuracies and automatically
corrects dry-end drift in the calibration curve.
Measurement range
Accuracy at +20 °C (+68 °F)
Typical temperature dependence
of electronics
Temperature sensor
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
Designed for industrial spot-checking and field
calibration
Three models: accurate measurement ranges from
-60 to +60 °C (-76 ... +140 °F)
Vaisala DRYCAP® Sensor with patented
autocalibration function
Low maintenance need due to superior long-term
stability
Sensor withstands condensation
Fast response, enhanced by Sensor Purge option
Easy-to-use user interface
Data can be logged and transferred to a PC via
MI70 Link software
Compact, small and light
NIST traceable (certificate included)
The Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70
measures dew point temperature accurately over a wide
measurement range. The probe may be inserted directly
into pressurized processes, and it responds rapidly from
ambient to process conditions. The sensor withstands
condensation and fully recovers from getting wet.
Three probe models, all with auto-calibration, are
available. The A and B models are both general purpose
probes. The C model is specifically developed for SF6 gas.
The B and C probe models have an additional Sensor
Purge feature that heats and dries the sensor, making the
82
The DM70 displays one to three parameters at a time,
either numerically or graphically. Several humidity units
can be selected. In addition, the DM70 includes conversion
from gas pressure dew point to ambient pressure dew
point. An analog output is also available.
The DM70 meter is suitable for direct process dew point
measurement in a wide temperature and pressure range.
For more demanding applications, the DM70 can be used
with the Vaisala sampling cell adapters, or with the Vaisala
DRYCAP® Sampling System DSS70A.
Dew point converted to atmospheric pressure, ppm volume and
ppm weight concentration, absolute humidity, mixing ratio, relative
humidity
DEW POINT
Measurement range (typical)
Accuracy (B and C probe) -60...+20 °C
Dotted line:
For DMP74C the ±2 °C accuracy range is limited to -50 °C Td when
used in SF6 gas.
Response time
flow rate 0.2 m/s, 1 bar pressure, +20 °C (+68 °F)
63% [90%]
0 -> -60 °C Td (32 -> -76 °F Td)
50 s [340 s]
-60 -> 0 °C Td (-76 -> 32 °F Td)
10 s [20 s]
Dew point sensor
Vaisala DRYCAP® 180M
TEMPERATURE
DEW POINT
OTHER VARIABLES AVAILABLE
-50 ... +60 °C (-58 ... +140 °F)
±2 °C (±3.6 °F)
(see graph)
-70 ... +30 °C (-94 ... +86 °F)
±2 °C (±3.6 °F)
(see graph)
Dew point accuracy
vs. measurement
conditions
Measured variables, DMP74A probe
Measurement range (typical)
Accuracy (A probe) -40...+60 °C
-10 ... +60 °C (+14 ... +140 °F)
±0.2 °C (±0.36 °F)
±0.005 °C/°C (±0.005 °F/°F)
Pt100 IEC751 1/3 class B
Dew point converted to atmospheric pressure, ppm volume and
ppm weight concentration
All probe models
Dew point accuracy
vs. measurement
conditions
Response time
flow rate 0.2 m/s, 1 bar pressure, +20 °C (+68 °F)
63% [90%]
0 -> -40 °C Td (32 -> -40 °F Td)
20 s [120 s]
-40 -> 0 °C Td (-40 -> 32 °F Td)
10 s [20 s]
Dew point sensor
Vaisala DRYCAP® 180S
Sample flow rate
no effect for measurement accuracy
Measured gases
non-corrosive gases
Probe material (wetted parts)
Stainless steel (AISI 316L)
Sensor protection
Sintered filter (AISI 316L)
partno: HM47280
Mechanical connection
G1/2” ISO228-1 thread
with bonded seal ring (U-seal)
Housing classification
IP65 (NEMA 4)
Weight
350 g
MI70 indicator, general
Measured variables, DMP74B and DMP74C
(for SF6 gas) probes
Measurement range
Accuracy at +20 °C (+68 °F)
Typical temperature dependence
of electronics
Temperature sensor
Technical data
±0.005 °C/°C (±0.005 °F/°F)
Pt100 IEC751 1/3 class B
OTHER VARIABLES AVAILABLE
The DM70 has a versatile and easy-to-use, menu-based
user interface, a clear graphical LCD display, and datalogging capability. It can also be used as a tool for reading
the output of fixed Vaisala dew point transmitters, like the
DMT242, DMT142, DMT152 and DMT340.
Features/Benefits
-10 ... +60 °C (+14 ... +140 °F)
±0.2 °C (±0.36 °F)
Operating temperature
Operating pressure
DMP74A, DMP74B
DMP74C
-10 ... +60 °C (+14 ... +140 °F)
0 ... 20 bara (0 ... 290 psia)
0 ... 10 bara (0 ... 150 psia)
Menu languages
English, Chinese, Spanish, Russian, French,
Japanese, German, Swedish, Finnish,
Display
LCD with backlight
Graphic trend display of any parameter
Character height up to 16 mm
Max. no of probes
2
Power supply
Rechargeable NiMH battery pack with AC-adapter
or 4xAA size alkalines, type IEC LR6
Analog output
0...1 VDC
Output resolution
0.6 mV
PC interface
MI70 Link software with USB or serial port cable
Datalogging capacity
2700 points
Alarm
Audible alarm function
Operating temperature range
-10...+40 °C (+14…+104 °F)
Storage temperature range
-40 ... +70 °C (-40 ... +158 °F)
Operating humidity range
0 ... 100 % RH, non-condensing
Housing classification
IP54
Housing materials
ABS/PC blend
Weight
400 g
Battery operation time with DMP74 probe
continuous use
48 h typical at +20 °C (+68 °F)
data logging use up to a month, depending on logging interval
Electromagnetic compatibility
EN 61326-1, Generic Environment
Accessories
Connection cables for fixed Vaisala dew point transmitters
for DMT242 transmitter
27160ZZ
for DMT340 series
211339
for DMT152 transmitter
219980
for DMT142 transmitter
211917ZZ
MI70 Link software with USB cable
219687
MI70 Link software with serial port cable
MI70LINK
Analog output cable
27168ZZ
10 m (32.81 ft) extension cable for probe
213107SP
Ref. B010162EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
83
www.vaisala.com
DSS70A Portable Sampling System
and Sampling Cells for DM70
Technical data
DMCOIL
DMT242SC
pressure limit
DMT242SC2
DSS70A Sampling System and
DSC74B/C Sampling Cells
Filter
Sample Gas
Inlet
Sampling Cell
for Td Probe
Needle Valve
Flow meter
Sample Pump
Sample Gas
Outlet
pressure limit
Material for all sampling cells
DSS70A
The DSS70A sampling system includes a filter to clean the dirty
sample gas and a needle valve to control the sample flow rate
with the flow meter. A sample pump is used to generate a sample
flow from processes at ambient pressure.
Measurement
in gas
pressure
Sampling Cell
for Td Probe
Valve
Removable
flow limiter
Sample gas
outlet
Sample gas
inlet
DSC74B
DSS70A portable
sampling system
The DSS70A is designed to provide
dewpoint sampling flexibility: for the
DM70 hand-held dew point meter. For
processes at atmospheric pressure,
a battery powered pump is used to
extract a gas sample. For pressurized
processes up to 20 bar, the sample
is measured at process pressure
and then reduced to atmospheric
pressure for venting or re-direction,
bypassing the pump. In all cases, the
sample gas passes through a filter to
remove particulate contamination
before measurement. Flow through
the system is controlled and
monitored with a needle valve and
flow meter.
The DSS70A is easily connected to
an appropriate sample point with
tubing (typically 1/4” or 6 mm).
The measured dewpoint must be
below ambient temperature to avoid
condensation in the system. Gas
84
temperatures higher than +40 °C
(+104 °F) should be cooled with a
short PTFE (included in the DSS70A
system) or stainless steel tube prior
to entering the DSS70A.
Sampling cells for
pressurized processes
The DM70 can easily be connected to
pressurized processes. In addition to
direct pipeline installation, a variety
of sampling cell options are available
for gas sampling.
The DSC74 sampling cell is the
recommended choice. It has a variety
of connection adapters that allow
several different ways of installation.
The quick connector with a leak
screw allows a very fast connection
for compressed air lines. Additionally,
two thread adapters are available for
the inlet port.
The DSC74B is a two-pressure
sampling cell, which enables
measurements in both process and
DSS70A sampling system
Operating conditions
Operating gases
Dewpoint range
Inlet/outlet connection
Operating temperature
ambient temperature
process gas temperature
with PTFE tube at +20 °C (+68 °F)
with stainless steel tube
Sample gas
outlet
The DSS70A provides a compact solution for field checking dew point where direct
measurement is difficult.Typical applications for the sampling system are metal
treatment and plastics drying processes.
Measurement in
atmospheric
pressure
ambient pressure. This sampling cell
is especially suitable for dewpoint
measurements in SF6 gas with the
DMP74C probe.
The DMT242SC is a basic sampling
cell. The DMT242SC2 is a sampling
cell supplied with welded Swagelok
connectors for sampling in a 1/4”
pipeline.
Sample gas
inlet
Removable
flow limiter
Valve
Sampling Cell
for Td Probe
DSC74B
Diffusion coil
(included in the DSS70A)
maximum gas temperature at inlet
Operating pressure
with pump
pump disconnected
air, N2 and other non-toxic,
inert gases
-70 °C ... Tamb (-76 °F ... Tamb)
1/4" Swagelok
0 ... +40 °C (32 ... +104 °F)
max. +200 °C (+392 °F)
specification according to
stainless steel tube specification
+40 °C (+104 °F)
0.6 ... 1.2 bara (8.7 ... 17.4 psia)
0 ... 20 bara (0 ... 290 psia)
DSC74C
The DSC74B sampling cell enables the measurement of the
sampled gas either in gas pressure up to 10 bar or in atmospheric
pressure depending on the gas inlet and outlet. The DSC74C
is like the DSC74B but with an additional coil to avoid back
diffusion, the effect of surrounding moisture, in dewpoint
measurements in atmospheric pressure.
Sampling cells technical data
DSC74
pressure limit
DSC74B
pressure limit
DSC74C
The sampling cells (from the left)
DMT242SC2, DMT242SC and DSC74 can
be used to connect the DM70 to sample
gas flow.The DSC74B (right) is a twopressure sampling cell that can be used
for measurements in either pressurized
or ambient pressure.The cooling/venting
coil is included in the DSC74C sample
cell, but is an option for all sampling cells.
cooling/venting coil
sampling cell
10 MPa (100 barg, 1450 psig)
sampling cell with Swagelok
connectors
4 MPa (40 barg, 580 psig)
stainless steel AISI316
sampling cell for pressurized gases
1 MPa (10 barg, 145 psig)
two pressure sampling cell
1 MPa (10 barg, 145 psig)
DSC74B with DMCOIL cooling/
venting coil
General
Battery operation time for pump
8 h continuous use
battery can be recharged using DM70 charger
Filter
7 mm inline filter cartridge 1/4"
Swagelok SS-4F-7
(spare part order no. 210801)
Materials
wetted parts
Stainless steel
carrying case
ABS plastic
Case size (W x D x H)
430 x 330 x 100 mm
Weight
5.5 kg (12 lbs)
Electromagnetic compatibility
EN61326-1, Generic Environment.
Ref. B210833EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
85
Moisture in Oil
www.vaisala.com
MMT330 Moisture and Temperature
Transmitter Series for Oil
Water content as ppm
conversion
zoom in on any desired time or time
frame.
In addition to water activity, the
MMT330 can output ppm, the average
mass concentration of water in oil.
Vaisala has this conversion readily
availabe for mineral transformer oil.
The display alarm allows tracking
of any measured parameter, with a
freely configurable low and high limit.
For other oils, the oil specific
conversion coefficients can be
programmed to the transmitter if the
water solubility of the oil is known.
The display shows measurement trends,
real time data and history.
Graphical measurement
trend and historical
display
The MMT330 can be ordered with a
large numerical and graphical display
with a multilingual menu. It allows
the user to monitor operational data,
measurement trends and up to 1-year
measurement history. The optional
data logger with real-time clock
makes it possible to generate over
four years of measured history, and
Data collection and
(wireless) transfer to PC
The recorded measurement data
can be viewed on the display or
transferred to a PC with Microsoft
Windows® software. The transmitter
can also be connected to a network
with an optional (W)LAN interface,
which enables a (wireless) Ethernet
connection.
Versatile outputs and
easy installation
The MMT330 provides up to three
analog outputs. Galvanic isolation of
supply power and analog outputs is
also available. For serial interface the
USB connection, RS232 and RS485
The Vaisala HUMICAP® Hand-Held
Moisture for Oil Meter MM70 is
designed for field checking MMT330
transmitters.
can be used. In addition, alarm relay
option is available.
The MMT330 has several options for
transmitter mounting. Transmitters
are delivered pre-configured with all
settings installation ready.
The MMT330 transmitter family offers a range of solutions for demanding moisture
in oil measurements.
Features/Benefits
▪
Continuous on-line
measurement of moisture in oil
▪
Ball valve installation – no need
to shut down the process
▪
Incorporates Vaisala HUMICAP®
Sensor – more than 30 years of
field performance
▪
Ten years of experience in
measuring moisture in oil
▪
▪
Excellent long-term stability
Easy to calibrate and maintain
in the field - Compatible with
Vaisala HUMICAP® Hand-Held
Moisture for Oil Meter MM70
▪
NIST traceable calibration
(certificate included)
▪
Analog outputs, WLAN/LAN
86
The Vaisala HUMICAP® Moisture
and Temperature Transmitter Series
for Oil MMT330 enables fast and
reliable detection of moisture in oil.
The MMT330 can be used in on-line
moisture monitoring and as a control
device, allowing separators and
oil driers to be started only when
needed.
Proper monitoring saves both oil and
the environment. With the MMT330
it is easy and economical to monitor
the changes of moisture in oil.
Reliable Vaisala
HUMICAP® technology
The MMT330 incorporates the latest
generation of the Vaisala HUMICAP®
Sensor, which is the result of ten
years of field experience. It was
developed for demanding moisture
measurement in liquid hydrocarbons.
The sensor's excellent chemical
tolerance provides accurate and
reliable measurement over a wide
measurement range.
For diverse applications
and demanding
conditions
Because of the variety of probes, the
transmitter can be used in lubrication
systems, hydraulic systems, and
transformers.
Indicates the margin to
water saturation
The MMT330 measures moisture in
oil in terms of the water activity (aw)
and temperature (T). Water activity
indicates directly whether there is
a risk of free water formation. The
measurement is also independent of
oil type and age.
87
Technical data
Installation options
Dimensions
Measured values
MMT332 For High Pressure
Installations
Dimensions in mm (inches)
WATER ACTIVITY
ΠFlange
36 mm / 1.4 inch
Inputs and outputs
Mechanics
TEMPERATURE
MMT337 with Small Sized Probe
Dimensions in mm (inches)
)3/OR
.04
Dimensions
0 ... 10 bar / 0 ... 145 psia
Probe diameter
12 mm / 0.5 inch
Installation
Fitting Body
R 3/8" ISO
Fitting Body
1/2" ISO
Fitting Body
NPT 1/2"
Measurement range
MMT332
MMT337
MMT338
Accuracy at +20 °C (+68 °F)
Hex 22m
(0.87)
-40 ... +180 °C (-40 ... +356 °F)
-40 ... +180 °C (-40 ... +356 °F)
-40 ... +180 °C (-40 ... +356 °F)
± 0.2 °C (0.36 °F)
Operating environment
Operating temperature
for probes
for transmitter body
with display
Pressure range for probes
same as measurement ranges
-40 ... +60 °C (-40 ... +140 °F)
0 ... +60 °C (+32 ... +140 °F)
See probe specifications
Temperature
Measurement range
-40 ... +180 °C
(-40 ... 356 °F)
Dimensions
MMT338 with Probe for Pipeline
Installations
Dimensions in mm (inches)
up to 120 °C (248 °F) and 40 bar
Π0 ... 40 bar / 0 ... 580 psia
ΠInstallation options
Pressure range with ball valve
R1/2" ISO7/1
Adjustable length
35 ... 157/379 mm /
1.37 ... 6.2 /14.9 inch
Installation
Fitting Body
Fitting Body
Ball Valve Set
Sampling Cell
R1/2" ISO
NPT 1/2"
BALLVALVE-1
DMT242SC2
Temperature
Measurement range
88
Complies with EMC standard EN61326-1, Electrical equipment for
measurement, control and laboratory use - EMC requirements;
Industrial environment.
Performance
-40 ... +180 °C
(-40 ... 356 °F)
Installation options
Pressure range
The MMT338 is ideal for installations
in pressurized processes where the
probe needs to be removed while the
process is running.The probe depth is
adjustable.
Measurement range aw
0 ... 1
Accuracy (including nonlinearity, hysteresis and repeatability)
0 ... 0.9
±0.02
0.9 ... 1.0
±0.03
Response time (90 %) at +20 °C in still oil
(with stainless steel filter)
10 min.
Sensor
HUMICAP®
Temperature
Measurement range
The MMT337 probe, with optional
Swagelok connector, is ideal for tight
spaces with a thread connection.The
small probe is designed for integrating
into confined spaces with small
diameter lines.
ΠInstallation
ΠThe MMT332 probe is installed
using a flange. It is for high pressure
applications.
12 mm / 0.5 inch
-
Probe diameter
²
0 ... 250 bar /
0 ... 3625 psia
Pressure range
Max wire size
0.5 mm2 (AWG 20) stranded wires recommended
Digital outputs
RS-232, RS-485 (optional)
Service connection
RS-232, USB
Relay outputs
0.5 A, 250 VAC, SPDT, Potential Free (optional)
Ethernet interface (optional)
Supported standards
10/100Base-T
Connector
RJ45
Protocols
Telnet
WLAN interface (optional)
Supported standards
802.11b
Antenna connector type
RP-SMA
Protocols
Telnet
Security
WEP 64/128,WPA
Authentication / Encryption
Open / no encryption
Open / WEP
WPA Pre shared key / TKIP
WPA Pre shared key / CCMP (a.k.a. WPA2)
Optional data logger with real-time clock
Logged parameters
max. three with trend/min/max values
Logging interval
10 sec (fixed)
Max. logging period
4 years 5 months
Logged points
13,7 million points per parameter
Battery lifetime
min. 5 years
Display
LCD with backlight, graphic
trend display of any parameter
Display menu languages
English, Chinese, Spanish, German,
French, Japanese, Russian, Swedish,
Finnish
-40 ... +180 °C
(-40 ... 356 °F)
Operating voltage
with optional power supply module
Power consumption @ 20 °C (Uin 24VDC)
RS-232
Uout 2 x 0...1V / 0...5V / 0...10V
Iout 2 x 0...20 mA
display and backlight
Analog outputs (2 standard, 3rd optional)
current output
voltage output
Accuracy of analog outputs at 20 °C
Temperature dependence of the
analog outputs
External loads
current ouputs
0 ... 1V output
0 ... 5V and 0 ... 10V outputs
10 ... 35 VDC, 24 VAC
100 ... 240 VAC 50/60 Hz
max 25 mA
max 25 mA
max 60 mA
+ 20 mA
0 ... 20 mA, 4 ... 20 mA
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
± 0.05 % full scale
Cable bushing M20x1.5 for cable diameter 8 ... 11mm/0.31 ... 0.43”
Conduit fitting
1/2”NPT
Interface cable connector (optional)
M12 series 8 pin (male)
option 1
with plug (female) with 5 m / 16.4 ft black cable
option 2
with plug (female) with screw terminals
USB-RJ45 Serial Connection Cable
219685
(incl. Mi70 Link software)
Probe cable diameter
5.5 mm
Probe cable lengths
2 m, 5 m or 10 m
Housing material
G-AlSi 10 Mg (DIN 1725)
Housing classification
IP 65 (NEMA 4X)
± 0.005 %/°C full scale
RL < 500 ohm
RL > 2 kohm
RL > 10 kohm
89
Mounting options
Dimensions
Dimensions in mm (inches)
Mounting with DIN Rail
Installation Kit
Pole Installation with Installation
Kit for Pole or Pipeline
ΠMounting with Wall
Mounting Kit
Mounting Rain Shield
with Installation Kit
Don’t
measure
the damage.
Prevent it.
HUMICAP® is a registered trademark of Vaisala.
New intelligence for measuring moisture in oil.
On-line, real time measurement
▪ without
sampling
▪
▪
Installation through ball valve
– no need to shut down the process
High stability in extreme conditions
Know your oil better –
Vaisala HUMICAP® instruments!
Download the 'Top 8 FAQs - Measuring
moisture in oil' at www.vaisala.com/mioFAQ
Instruments display water activity trends.
TYPE APPROVED PRODUCT
CERTIFICATE NO.: A-11440
For more information, visit
www.vaisala.com or contact
us at [email protected]
90
Ref. B210953EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
www.vaisala.com/mioFAQ
[email protected]
91
www.vaisala.com
MMT310 Series Moisture and Temperature
Transmitter for Oil
Technical data
Measured values
General
WATER ACTIVITY
Water content as
ppm calculation for
transformer oils
PPM units are traditionally used
in transformer applications.
They indicate the average mass
concentration of water in oil. The
ppm calculation for mineral oil based
transformer oil is optional in the
MMT310 series.
Diverse applications and
demanding conditions
The MMT310 series can be used in
lubrication and hydraulic systems
as well as in transformers. It can be
used for on-line moisture monitoring
and as a control function, allowing
separators and oil purifiers to be
started only when necessary.
Two probe options: MMT317 and MMT318
▪
Continuous measurement of
moisture in oil
▪
The Vaisala HUMICAP® Moisture and
Temperature Transmitter Series for
Oil MMT310 is a fast and reliable online detector for moisture in oil.
Proven Vaisala HUMICAP®
sensor, 10 years in oil
applications
Reliable Vaisala
HUMICAP® technology
▪
Measurements in lubrication,
hydraulic and transformer oils
▪
Excellent pressure and
temperature tolerance
▪
Measuring water activity - ppm
calculation for transformer oil
▪
▪
▪
Small size, easy to integrate
Features/Benefits
The MMT310 series incorporates
the latest generation of the Vaisala
HUMICAP® Sensor, developed for
demanding moisture measurement
in liquid hydrocarbons. The sensor’s
excellent chemical tolerance provides
accurate and reliable measurement
over the wide measurement range.
NIST traceable calibration
Applications: e.g. monitoring
of transformer oil and of
lubrication systems in marine
and paper industry
Measuring water activity
The MMT310 series measures
moisture in oil in terms of the water
activity (aw) and temperature (T).
Water activity directly indicates if
there is a risk of free water formation.
The measurement is independent of
oil type, age, and temperature.
92
Installation options
The MMT318 has two adjustable
probe lengths. The transmitter can
be ordered with a ball valve set that
enables the insertion and removal of
the moisture probe for calibration,
without the need to empty the oil
system.
Measurement range aw
Accuracy (including non-linearity,
hysteresis and repeatability)
0 ... 0.9
0.9 ... 1.0
Response time (90 %) at +20 ˚C in still oil
(with stainless steel filter)
Sensor
0 ... 1
±0.02
±0.03
10 min
Vaisala HUMICAP®
TEMPERATURE
Measurement range
Typical accuracy at +20 ˚C
Typical temperature dependence
of electronics
Sensor
-40 ... +180 ˚C (-40 ... +356 ˚F)
±0.1 ˚C (±0.18 ˚F)
±0.05˚C/ ˚C (±0.005 ˚F/˚F)
Pt100 IEC751/3 class B
Electrical connections
Two analog outputs, selectable and
scalable
0 ... 20 mA or 4 ... 20 mA
Typical accuracy of analog output at +20 ˚C
±0.05 % full scale
Typical temperature dependence
0.005 %/˚C (0.003 %/˚F)
of analog output
full scale
Serial output
RS-232C
Connections
8-pole connector with RS-232C, current
outputs (two channels) and Uin
Operating voltage Uin
24 VDC (10 ... 35 VDC)
Minimum operating voltage Uin
with RS-232C
10 VDC
11 VDC + (Rload/60) VDC
Iout 0 ... 20 mA, 4 ... 20 mA
Power consumption at +20 ˚C, Uin = 24 VDC
with RS-232C
20 mA
60 mA
Iout 2 x 0 ... 20 mA
Operating temperature range for
electronics
-40 ... +60 ˚C (-40 ... +140 ˚F)
Storage temperature
-55 ... +80 ˚C (-67 ... +176 ˚F)
Pressure range for MMT318 with ball
valve up to 120 ˚C
0 ... 40 bar
Pressure range for MMT317
0 ... 10 bar
External load
R1<500 Ohm
Material
transmitter housing
G-AlSi 10 Mg
transmitter base
ABS/PC
Housing classification
IP65
to be protected from direct rain
Cable feed through alternatives 8-pole connector with 5 m cable,
female 8-pin connector screw
joint for cable diameter 4 ... 8 mm
Sensor protection
stainless steel grid
Probe cable length
MMT317
0.5, 2, 5 or 10 meters
MMT318
2, 5 or 10 meters
Probe installation MMT317
Swagelok®
NPT 1/2”, ISO 3/8” or ISO 1/2”
Probe installation MMT318
Fitting bodies
ISO 1/2”, NPT 1/2”
Ball Valve Set
BALLVALVE-1
Complies with EMC standard EN61326-1, Industrial environment
Note: When using the current output, the RF field susceptibility
level according to standard EN61000-4-3 with a frequency band
of 110 ... 165 MHz, is only 3 V/m (generic environment) with the
specified accuracy.
HUMICAP® is a registered trademark of Vaisala.
The MMT317 has a small pressuretight probe with optional Swagelok
fittings.
Several outputs, one
connector
The MMT310 series has two analog
outputs and an RS-232 serial output.
The output signals and the supply
power travel in the same cable, the
only cable connected to the unit.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210831EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
93
www.vaisala.com
MMT162 Compact Moisture in Oil and
Temperature Transmitter for OEM Applications
Water activity
measurement
The MMT162 measures moisture in
oil in terms of the water activity (aw)
and temperature (T). Water activity
directly indicates whether there is
a risk of free water formation. The
measurement is independent of oil
type, age and temperature. The ppm
calculation for mineral oil based
transformer oil is optional in the
MMT162.
Several outputs - one
connector
The MMT162 enables on-line moisture monitoring in oils even in the most
demanding applications.
Features/Benefits
®
The Vaisala HUMICAP Moisture
and Temperature Transmitter for Oil
MMT162 is an excellent economical
solution for reliable on-line detection
of moisture in oil.
▪
Continuous measurement of
moisture in oil
▪
Measures in lubrication,
hydraulic and transformer oils
▪
Excellent pressure and
temperature tolerance
Reliable Vaisala
HUMICAP ® technology
▪
Vaisala HUMICAP® Sensor
- proven in the field since 1973
▪
Measures water activity
- ppm-calculation available for
transformer oil
The MMT162 incorporates the latest
generation of the Vaisala HUMICAP®
Sensor. The sensor is developed for
demanding moisture measurement
in liquid hydrocarbons and has been
successfully used in oil applications
for over a decade. The sensor’s
excellent chemical tolerance provides
accurate and reliable measurement
over the measurement range.
▪
▪
Small size, easy to integrate
NIST traceable calibration
(certificate included)
The MMT162 has two analog
outputs that can be scaled and
the measurement ranges changed.
Additionally, the transmitter has an
RS-485 serial output. The signals and
the unit power travel in the same
cable.
Technical data
Measured Values
General
WATER ACTIVITY
Sensor
HUMICAP®
Cable connections (2 ports)
M8, 4 pin
Minimum operating voltage with
RS-485 output
14 ... 28 VDC
voltage output
16 ... 28 VDC
current output
22 ... 28 VDC
Supply current
normal measurement
20 mA + load current
External load for
voltage output
min. 10 kOhm
current output
max. 500 Ohm
Housing material
metal
AISI 316L
plastic
PPS + 40% GF
Mechanical connections with bonded seal ring (washer)
metal version
G 1/2’’ ISO or NPT 1/2’’
plastic version
G 1/2’’ ISO
Housing classification
IP65 (NEMA 4)
Storage temperature range
-40 ... +80 °C (-40 ... +176 °F)
Weight
with plastic housing
65 g (2.3 oz)
with metal housing
200 g (7 oz)
Complies with EMC standard EN61326-1, Electrical equipment
for measurement control and laboratory use - EMC requirements;
Industrial environment
Measurement range
0 ... 1 aw
Accuracy (including non-linearity, hysteresis and repeatability)
0 ... 0.9
± 0.02
0.9 ... 1.0
± 0.03
Response time
in oil flow (typical)
<1 min (dry-wet)
MOISTURE
Calculated moisture content in ppm for mineral transformer oil
TEMPERATURE
Accuracy at +20 °C (+68 °F)
± 0.2 °C (0.36 °F)
Operating Environment
Operating temperature
Oil temperature
Pressure range
metal version
plastic version
Oil flow
-40 ... +60 °C (-40 ... +140 °F)
-40 ... +80 °C (-40 ... +176 °F)
up to 200 bar
up to 40 bar
some flow recommended
Outputs
Analog outputs (two channels)
current output
voltage output
Alarm level indication by analog signal
Digital outputs
0 ... 20 mA, 4 ... 20 mA
0 ... 5 V, 0 ... 10 V
user selectable
RS-485
Stainless steel filter (standard)
Stainless steel filter for high flow (>1 m/s)
Connection cable for MM70 hand-held meter
USB serial interface cable
Sealing ring set (U-seal) ISO G1/2, 3 pcs
Sealing ring set (copper) ISO G1/2, 3 pcs
ISO 1/2’’ plug
NPT 1/2’’ plug
Sampling cell
Sampling cell w. Swagelok connectors
Connection cable
2 m (6.5 ft), M8 snap-on
0.32 m (1 ft) Shielded, M8 threaded
3.0 m (9.8 ft), Shielded, M8 threaded
5.0 m (16.4 ft), Shielded, M8 threaded
10 m (32.8 ft), Shielded, M8 threaded
3 m, Shielded, connector 90° angle
5 m, Shielded, connector 90° angle
M8 threaded, Ch1 signal + Ch2 LED
An optional LED-cable enables a
visual alarm.
Compact, rugged
and intelligent
Due to its compact size, the MMT162
is quickly and easily installed in
tight spaces. Units are delivered fully
assembled, however, you can reconfigure them to suit your needs.
MM70
In combination with an MM70
indicator, the MMT162 provides an
ideal tool for on site calibration.
The MI70 indicator can be used as a
display, communication, and datalogging device for the MMT162.
For more information, visit
www.vaisala.com or contact
us at [email protected]
94
Options and accessories
221494SP
221493SP
219980
219690
221525SP
221524SP
218773
222507
DMT242SC
DMT242SC2
211598
HMP50Z032
HMP50Z300
HMP50Z500
HMP50Z1000
221739
221740
MP300LEDCBL
Ref. B210755EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
95
MM70 Hand-Held Moisture and Temperature
Meter for Spot-Checking in Oil
Numerical and
graphical display
The MM70 features a multilingual,
menu-based user interface and a
backlit LCD display. The measurement
parameters can be numerically and
graphically displayed and logged
into the meter's memory at the same
time. An analog output option is also
available.
The MM70 is an ideal
tool for the preventive
maintenance of oil-filled
systems.The water
activity measurement
indicates the margin to
free water formation,
which causes severe
problems in lubrication
systems.
Features/Benefits
▪
Measurement independent of
oil type, age and temperature
▪
In-line process checking
through ball valve, no need to
drain the oil
▪
Rugged and reliable
construction
▪
Excellent pressure and
temperature tolerance
▪
Data can be logged and
transferred to a PC
▪
Vaisala HUMICAP® Sensor proven field performance
since 1973
▪
Compatible with Vaisala’s fixed
oil moisture instruments
▪
No reference oil needed for
recalibration
▪
NIST traceable (certificate
included)
96
The Vaisala HUMICAP® Hand-held
Moisture Meter for Oil MM70 enables
reliable detection of moisture in oil.
In-line process checking
through ball valve
The probe can be inserted directly
into the process pipe through a ball
valve without draining the oil in the
system.
Water activity
measurement
The MM70 measures moisture in oil
in terms of the water activity (aw)
and temperature (T). Water activity
directly indicates whether there is
a risk of free water formation. The
measurement is independent of oil
type, age and temperature.
ppm calculation included
The MM70 has an embedded model
for expressing moisture as ppm in
mineral transformer oil. The customer
can enter up to three other oil models
into the meter’s memory.
Connection to PC
The optional MI70 Link Windows®
software in combination with a
USB connection cable is used to
transfer logged data and real time
measurement data from the MM70
to a PC.
Proven Vaisala HUMICAP®
technology
The MM70 incorporates the latest
generation of the Vaisala HUMICAP®
Sensor, developed for demanding
moisture measurements in liquid
hydrocarbons. The sensor’s excellent
chemical tolerance provides accurate
and reliable measurement over the
measurement range.
Speedy service once a year
The meter can be recalibrated
by sending the probe to Vaisala
Service, or customers can calibrate
the instrument themselves using a
standard relative humidity calibration.
Multi-probe operation
One or two probes can be connected
simultaneously. Maintenance teams
can use additional Vaisala dewpoint
or relative humidity probes for other
tasks. For example, a dewpoint probe
is ideal for checking the moisture
inside washed and dried oil tanks.
Technical data
Performance
Display
WATER ACTIVITY
Measurement range aw
0 ... 1
Accuracy (including nonlinearity, hysteresis and repeatability)
When calibrated against salt solutions (ASTM E104-85):
0 ... 0.9
±0.02
0.9 ... 1.0
±0.03
Maximum achievable accuracy when calibrated against
high-quality, certified humidity standards:
0 ... 0.9
±0.01
0.9 ... 1.0
±0.02
Response time (90%) at +20 °C (+68 °F)
in still oil (with stainless steel filter)
10 min.
Sensor
Vaisala HUMICAP®
Recommended recalibration interval
1 year
TEMPERATURE
Measurement range
Typical accuracy at +20 °C
Typical temperature dependence
of electronics
Sensor
Typical long-term stability
-40 ... +100 °C (-40 ... +212 °F)
±0.2 °C (±0.36 °F)
±0.005 °C/°C (±0.005 °F/°F)
Pt 100 IEC 751 1/3 class B
better than 0.01 aw / year
Operating environment
PROBE
Operating temperature range for electronics
Operating pressure range
during installation through ball valve
Oil flow range
-40 ... +60 °C
(-40 ... +140 °F)
max. 20 bar
max. 10 bar
max. 1 m/s
INDICATOR
Operating temperature range
Operating humidity range
-10 ... +40 °C (+14 ... +104 °F)
non-condensing
ELECTROMAGNETIC COMPATIBILITY
Complies with EMC standard EN61326-1, Electrical equipment for
measurement, control and laboratory use - EMC requirements;
Portable equipment.
LCD with backlight, graphic trend display of
any parameter, character height up to 16 mm
Analog output
0 ... 1 VDC
Output resolution
0.6 mV
PC interface
MI70 Link software with USB or serial port cable
Data logging capacity
2700 points
Alarm
Audible alarm function
Mechanics
PROBE
Housing classification
IP65 (NEMA 4)
Housing material
ABS/PC blend
Probe material
Stainless steel (AISI316L)
Cable length between probe and indicator
1.9 m,
10 m extension available
Weight
506 g
INDICATOR
Housing classification
Weight
Probe inputs
IP54
400 g
1 or 2
Options and accessories
Carrying case
MI70CASE2
Ball valve set (incl. fitting body & blanking plug)
HMP228BVS
Probe cable extension, 10 m
213107SP
Transmitter connection cables for
HMP228
27159ZZ
MMT318
DRW216050
MMT/HMT330/DMT340
211339
MI70 Link software with USB cable
219687
MI70 Link software with serial port cable
MI70LINK
Analog output cable
27168ZZ
Sensor protection
HM47453SP
Dewpoint measurement probes
DMP74A/B
Relative humidity measurement probes
HMP75, HMP76, HMP77
Dimensions
Dimensions in mm (inches)
Inputs and outputs
Power supply
Rechargeable NiMH battery pack with
AC-adapter or 4xAA-size alkalines, type IEC LR6
Battery operation time
continuous use
48 h typical at +20 °C (+68 °F)
data logging use
up to a month, depending on
logging interval
Menu languages
English, Chinese, Spanish, French, German,
Japanese, Russian, Swedish, Finnish
R1/2" ISO 7/1
www.vaisala.com
Adjustment range 250 mm
HUMICAP® is a registered trademark of Vaisala.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210960EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
97
Carbon Dioxide
www.vaisala.com
GMP343 Carbon Dioxide Probe for Demanding
Measurements
Features/Benefits
▪
▪
Excellent accuracy and stability
▪
A single-beam, dualwavelength CO2 measurement
with no moving parts
▪
Vaisala CARBOCAP® Sensor,
a silicon-based non-dispersive
infrared (NDIR) sensor
Compensation options
for temperature, pressure,
humidity and oxygen
Technical data
PRESSURE
Inputs and outputs
Effect on accuracy with pressure compensation:
0 ... 1000 ppm
0 ... 2000 - 2 %
CO2 range options
Pressure (hPa)
Accuracy (% of reading)
900 ... 1050
±0.5
±1
700 ... 1300
±1
±2
Integrated pressure sensor is not included in GMP343
Operating voltage
Power consumption
without optics heating
with optics heating
Long term stability
easy
moderate
harsh
see graph below
<±2 % of reading / year
<±2 % of reading / 6 months
<±2 % of reading / 3 months
GMP343 OPERATING CONDITIONS
11 ... 36 VDC
<1 W
<3.5 W
ANALOG OUTPUTS
Current output
range
resolution
max. load
Voltage output
range
resolution
min. load
4 ... 20 mA
14 bits
800 Ohm @ 24 VDC, 150 Ohm @ 10 VDC
0 ... 2.5 V, 0 ... 5 V
14 bits (13 bits with 0 ... 2.5 V)
5 kOhm
RS485, RS232
DIGITAL OUTPUTS
▪
Low power consumption and
heat emission
▪
▪
Designed for outdoor use
Materials
Response time (90 %)
Compact and lightweight
DIFFUSION MODEL
Filter attached
Yes
Yes
No
No
The GMP343 is available as an open-path diffusion-aspirated model (left) and as a
flow-through model (right).
Averaging (s)
0
30
0
30
Response (s)
75
82
<2
30
Averaging (s)
0
30
0
30
Response (s)
26
44
8
23
Housing
Filter cover
IP classification
Housing (cable attached)
Diffusion filter (weather protection)
Diffusion filter (sintered PTFE)
Cable connector type
Weight (probe only)
anodized aluminium
PC
<1 W
IP67
IP65
IP66
8-pin M12
360 g
FLOW-THROUGH MODEL
®
The Vaisala CARBOCAP Carbon Dioxide Probe
GMP343 is an accurate and rugged probe-type
instrument for ecological measurements. Typical
applications include CO2 soil respiration, ambient
CO2 monitoring, plant growth chambers, and
OEM applications.
The GMP343 can output both numerically filtered
and raw measurement data and it can also
compensate the measurement with an internal
temperature measurement and user-set relative
humidity, pressure and oxygen values.
Technical data
Performance
Measurement range options
0 ... 1000 ppm, 0 ... 2000 ppm,
0 ... 3000 ppm, 0 ... 4000 ppm,
0 ... 5000 ppm, 0 ... 2 %
Accuracy (excluding noise) at 25 °C (77 °F) and 1013 hPa after factory
calibration with 0.5 % accurate gases with different range options
0 ... 1000 ppm
±(3 ppm + 1 % of reading)
0 ... 2000 ppm - 0 ... 2 %*
±(5 ppm + 2 % of reading)
*Accuracy below 200 ppm CO2 not specified for 2 % range option
In combination with an MI70 indicator, the GMP343
provides a tool for accurate in-situ measurement.
The MI70 can be used as a display, communication
and data logging device.
Noise (repeatability) at 370 ppm CO2
with no output averaging
with 30 s output averaging
Each GMP343 is calibrated using ±0.5 % accurate
gases at 0 ppm, 200 ppm, 370 ppm, 600 ppm,
1000 ppm, 4000 ppm and 2 %. Calibration is also
done at temperature points of -30 °C, 0 °C, 25 °C
and 50 °C. If needed, the customer can recalibrate
the instrument using the multipoint calibration
(MPC) feature allowing up to 8 user-defined
calibration points.
TEMPERATURE
98
Effect on accuracy with temperature compensation:
CO2 range options 0 ... 1000 ppm 0 ... 2 000 - 5000 ppm
Temperature °C (°F)
Accuracy (% of reading)
+10 ... +40 (+50 ... +104)
±1
±1
+40 ... +60 (+104 ... +140)
±2
±3
-40 ... +10 (-40 ... +50)
±3
±3
±3 ppm CO2
±1 ppm CO2
0 ... 2 %
±2
±4
±5
±5 ppm CO2
For readings below 200 ppm CO2
Temperature compensation is performed by an integrated Pt1000 element
Gas flow (l/min)
0.3
0.3
1.2
1.2
Warm-up time
full accuracy ±0.5 %
full accuracy
10 min
30 min
Operating Environment
Temperature
operating
-40 ... +60 °C (-40 ... +140 °F)
storage
-40 ... +70 °C (-40 ... 158 °F)
Humidity
see graph ‘GMP343 Operating Conditions’
Pressure
compensated range
700 ... 1300 hPa
operating
<5 bar
Gas flow for flow-through model
0 ... 10 liters/min
Electromagnetic compatibility
EN61326, Generic
Environment
For more information, visit
www.vaisala.com or contact
us at [email protected]
Options and accessories
Wall mount bracket
GMP343BRACKET
Mounting flange
GMP343FLANGE
Standard diffusion filter (weather
protection, IP65) +filter cover
GMP343FILTER
Diffusion filter (sintered PTFE
filter, IP66) + filter cover
215521
Calibration adapter (for the diffusion model)
GMP343ADAPTER
Junction box
JUNCTIONBOX-8
Probe cables
2m
GMP343Z200SP
6m
GMP343Z600SP
10m
GMP343Z1000SP
PC connection cable, 2m
213379
MI70 connection cable, 2m
DRW216050SP
USB adapter (USB-D9 Serial connection cable)
219686
Soil adapter kit for horizontal positioning
215519
Soil adapter kit for vertical positioning
215520
Ref. B210688EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
99
www.vaisala.com
GMT220 Series Carbon Dioxide Transmitters
for Industrial Applications
Technical data
Performance
Operating environment
Measurement Ranges
GMT221
for high concentrations
0 ... 2 %
0 ... 3 %
0 ... 5 %
0 ... 10 %
0 ... 20 %
GMT222
for low concentrations
Accuracy (including repeatability, non-linearity and
calibration uncertainty) at 25 °C and 1013 hPa
GMT221
±(1.5 % of range + 2 % of reading)
(applies for concentrations above 2 % of full scale)
GMT222
±(1.5 % of range + 2 % of reading)
Temperature dependence, typical
-0.3 % of reading / °C
Pressure dependence, typical
+0.15 % of reading/hPa
Long-term stability
<±5 %FS/2 years
Response time (63 %)
GMT221
20 seconds
GMT222
30 seconds
Warm-up time
30 seconds, 15 minutes full specifications
The GMT220 transmitters withstand harsh and humid environments.
Features/Benefits
▪
▪
▪
▪
▪
Incorporates Vaisala
CARBOCAP® - the siliconbased NDIR sensor
IP65 protected against dust
and spray water
Several measurement ranges
Easy installation
Standard analog outputs
and two configurable relays
available
Applications include:
▪
▪
Horticulture and fruit storage
▪
Safety alarming and leakage
monitoring
▪
Demand controlled ventilation
in harsh environments
Greenhouses and mushroom
farming
100
The Vaisala CARBOCAP® Carbon
Dioxide Transmitter Series GMT220 is
designed to measure carbon dioxide
in harsh and humid environments.
The housing is dust- and waterproof
to IP65 standards.
The GMT220 series transmitters
incorporate the advanced Vaisala
CARBOCAP® Sensor. The patented
sensor has unique reference
measurement capabilities. Its critical
parts are made of silicon; this gives
the sensor outstanding stability
over both time and temperature. By
lengthening the calibration intervals,
the user saves both time and money.
Interchangeable probes
The user has a choice of
measurement ranges up to 20%
of CO2. The GMT221 is for higher
concentrations of CO2 and the
0 ... 2000 ppm
0 ... 3000 ppm
0 ... 5000 ppm
0 ... 7000 ppm
0 ... 10 000 ppm
GMT222 for lower concentrations
of CO2. The GMT220 probes are
interchangeable. They can be
removed and reattached or replaced
at any time – without the need for
calibration and adjustment. The
probes can be attached directly to
the transmitter body or, when used
with a cable, installed remotely into
hard-to-reach places or areas with
dangerously high levels of CO2.
The interchangeability of the GMT220
transmitter’s probes truly facilitates
field maintenance.
Inputs and outputs
Outputs
Resolution of analog outputs
Recommended external load:
current output
voltage output
Two pre-or user-defined relay
outputs
Relay contacts
Connections
Operating voltage
Power consumption
0 ... 20 or 4 ... 20 mA
and 0 ... 10 V
12 bits
max. 400 Ohm
min. 1 kOhm
Operating temperature
with display
Storage temperature
Humidity
Electromagnetic compatibility
-20 ... +60 °C (-4 ... +140 °F)
0 ... +50 °C (+32 ... +122 °F)
-30 ... +70 °C (-22 ... +158 °F)
0 ... 100 %RH, non-condensing
EN61326-1, Generic Environment
Mechanics
Housing material
transmitter body
probe
Housing classification
Weight:
GMT221
GMT222
Probe cable length
ABS plastic
PC plastic
IP65
max. 280 g
max. 300 g
2 m and 10 m (optional)
Accessories
Spare probe
GMP221, GMP222
(use the order form to define measurement range etc.)
Clips (2 pcs) for attaching the probe
25245GM
Mounting flange for the probe
GM45156
Probe cables
2m
25665GMSP
10 m
210848GMSP
Calibrator for interchangeable probes
GMK220
Wall Assembly Plate
GM45160
In-soil adapter for probe
211921GM
Serial COM adapter
19040GM
Calibration adapter for probe
26150GM
max. 30VAC/60VDC, 0.5A
screw terminals, 0.5 ... 1.5 mm2
nominal 24 VAC/DC
<4 W
The end user can carry out field
maintenance without any additional
equipment or heavy and expensive
calibration gas bottles by simply
replacing a probe.
Probes that have been replaced can
be sent to Vaisala for recalibration.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210827EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
101
www.vaisala.com
GMM220 Carbon Dioxide Modules for
Demanding OEM Applications
Technical data
Carbon dioxide
Mechanics
Measurement ranges
GMM221 for high concentrations
Probe housing material
PC plastic
Housing classification (probe only)
IP65
Weight: GMM221 (w/2m cable)
max. 180 g
Weight: GMM222 (w/2m cable)
max. 200 g
Probe cable length
0.6 m, 1 m (high temperature cable),
2 m, 6 m or 10 m (optional)
0 ... 2 %, 0 ... 3 %, 0 ... 5 %,
0 ... 10 %, 0 ... 20 %
GMM222 for low concentrations 0 ... 2000 ppm, 0 ... 3000 ppm,
0 ... 5000 ppm, 0 ... 7000 ppm,
0 ... 10 000 ppm
Accuracy (including repeatability, non-linearity and calibration
uncertainty) at 25 °C and 1013 hPa
GMM221
±(1.5% of range + 2% of
reading)
(applies for concentrations above 2% of full scale)
GMM222
±(1.5% of reading + 2% of
reading)
Temperature dependence, typical
-0.3 % of reading / °C
Pressure dependence, typical
+0.15% of reading hPa
Long-term stability
<±5 %FS/2 years
Response time (63 %)
GMM221
20 seconds
GMM222
30 seconds
Warm-up time
30 seconds, 15 minutes
full specifications
Accessories
Spare probe
GMP221, GMP222
(use the order form to define measurement range etc.)
Clips (2 pcs) for attaching the probe
25245GM
Mounting flange for the probe
GM45156
GMK220
CO2 Calibration Unit
Probe cables
1 m high temperature probe cable
(180 °C / 365 °F)
GMM220Z100SP
2 m probe cable
GMM220Z200SP
6 m probe cable
GMP343Z600SP
10.0 m probe cable
GMP343Z1000SP
Serial COM adapter
19040GM
Dimensions
Dimensions in mm (inches)
The Vaisala CARBOCAP® Carbon Dioxide Module Series GMM220 withstand
harsh conditions.They provide high carbon dioxide measurement accuracy
over wide temperature and relative humidity ranges.
Features/Benefits
▪
Incorporates Vaisala
CARBOCAP® - the silicon
based CO2 sensor
▪
Choice of several measurement
ranges
▪
IP65 protected probe against
dust and spray water
▪
Interchangeable probes
provide easy maintenance
▪
Modules optimized for
integration into equipment for
greenhouse control, incubators,
fermentors, safety alarming
and integrated systems.
For harsh environments
®
The Vaisala CARBOCAP Carbon
Dioxide Module Series GMM220 are
designed for Original Equipment
Manufacturers (OEM’s) requiring
carbon dioxide measurements in
harsh and demanding applications.
Vaisala CARBOCAP®
The GMM220 series modules
incorporate the industrial Vaisala
CARBOCAP® Sensor. The patented
sensor has unique reference
measurement capabilities. Its critical
parts are made of silicon; this gives
the sensor outstanding stability over
both time and temperature.
Since water vapor, dust, and
most chemicals do not affect the
measurement, the GMM220 series
modules can be used in harsh and
humid environments.
102
Inputs and outputs
Outputs
Interchangeable probes
The GMP220 probes are
interchangeable. They can be
removed, reattached or replaced at
any time – without the need for
calibration and adjustment. The
interchangeable probes make
calibration and field service easy. In
addition, the measurement range can
be changed simply by replacing one
probe with another.
Different configurations
The user has a choice of
measurement ranges up to 20 % CO2:
the Vaisala CARBOCAP® Carbon
Dioxide Module GMM221 for higher
and the Vaisala CARBOCAP® Carbon
Dioxide Module GMM222 for lower
concentrations of CO2.
Different power supply voltages,
output options, as well as cable
lengths, connectors, and mounting
gear are also available.
0 ... 20 or 4 ... 20 mA, 0 ... 1 V, 0 ... 2V,
0 ... 2.5 V, or 0 ... 5 V
12 bits
Resolution of analog outputs
Recommended external load:
current output
max. 200 Ohm
voltage output
min. 1 kOhm
Operating voltage
11 ... 20 VDC or 18 ... 30 VDC
Connections
screw terminals, wire size 0.5 ... 1.5 mm2
Power consumption
<2.5 W
GMP221
GMP222
Operating environment
Operating temperature
Storage temperature
Operating pressure
probe
mother board
Electromagnetic compatibility
-20 ... +60 °C (-4 ... +140 °F)
-30 ... +70 °C (-22 ... +158 °F)
700 ... 1300 hPa
0 ... 100 %RH, non-condensing
0 ... 85 %RH, non-condensing
EN61326-1, Generic Environment
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210856EN-C ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
103
www.vaisala.com
Technical data
GMM111 Carbon Dioxide Module
Dimensions
CO2 measurement range
0 ... 5 %, 0 ... 10 % or 0 ... 20 %
Accuracy (including repeatability,
non-linearity and calibration
uncertainty)
±(1.5% of range + 3 % of reading)
Long-term stability
±1 % CO2/2 years
Response time T90
1 min at 0.5 l/min flow
Dimensions in mm
Product lifetime
96
Ø3.2
65
no effect
4 % of reading/ l/min
-0.3 % of reading/°C
+0.15 % of reading/hPa
1 min, 10 min for full
specifications
> 10 years
mA
V
0
B
A
0
24V
TUBE I.D. Ø4
(TUBE O.D. Ø6)
6
Flow rate dependence
< 1 l/min flow
1 ... 10 l/min flow
Temperature dependence, typical
Pressure dependence, typical
Warm-up time
mA
V
0
B
A
0
24V
25
Performance
30
60
Operating environment
Temperature
+5 ... +55 °C (+41 ... +131 °F)
Humidity
0 ... 99 %RH non-condensing
Pressure
700 ... 1200 hPa
Gas flow
operating range
< 10 l/min
recommended range
0.2 ... 0.8 l/min
Electromagnetic compatibility
Complies with EMS Standard EN61326-1, Generic Environment
The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is a CO2 measurement
module with flow-through aspiration.
Features/Benefits
▪
Compact CO2 module with
flow-through aspiration
▪
Ideal for control of CO2
concentrations in incubators
▪
Incorporates Vaisala
CARBOCAP®, the silicon based
NDIR sensor with unique
internal referencing
▪
Advanced single-beam, dual
wavelength measurement with
no moving parts
▪
Measurement range options
0 ... 5 %, 0 ... 10 % and
0 ... 20 % CO2
▪
Excellent long-term stability
104
GMM111
The Vaisala CARBOCAP® Carbon
Dioxide Module GMM111 is
designed especially for control of
biological processes where high
CO2 concentrations are used. It has
3 optional measurement ranges
0 ... 5/10/20 % CO2. The GMM11 is a
flow-trough model and has barbed
conncectors for attaching the in and
out flow tubes. As the module is not
mounted in the chamber, the chamber
can be heatsterilized without
removing the module.
The Vaisala CARBOCAP® CO2
sensors have been proven to be
accurate anddurable. They have an
excellent long-term stability, which
decreases maintenance. The
superior performance of Vaisala
CARBOCAP® sensors results largely
from the stable reference provided by
the electrically tunable Fabry-Perot
Interferometer(FPI).
The tunable FPI filter measures CO2
absorption, and simultaneously a
reference wavelength. This internal
reference measurement compensates
effectively for any changes in the
optical path, such as light source
intensity changes and contamination.
In the HVAC market, this type of
reference measurement is a unique
feature to Vaisala CARBOCAP®
products.
The true internal reference
measurement of Vaisala CARBOCAP®
CO2 transmitters provides years of
stable CO2 measurements.
Inputs and outputs
Outputs
Operating voltage
Power consumption
4 ... 20 mA, 0 ... 10 V
RS485, 2-wire, non-isolated
24 V (±20 %) AC/DC
<2 W
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210566EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
105
www.vaisala.com
GM70 Hand-Held Carbon Dioxide Meter
for Spot-Checking Applications
accuracy is not affected by dust,
water vapor or most chemicals. The
GM70 has a two-year recommended
calibration interval.
The Vaisala CARBOCAP® Hand-Held Carbon Dioxide Meter GM70 is the demanding
professional’s choice for hand-held carbon dioxide measurement.The meter consists
of the indicator (center) and probe, used either with the handle (left) or pump (right).
Features/Benefits
▪
▪
Proven Vaisala CARBOCAP®
reliability
Two optional sampling
methods: diffusion or pump
aspiration
▪
User-friendly meter with
multilingual user interface
▪
Numerical and graphical
display of measurements
▪
Data can be logged and
transferred to PC via MI70 Link
software
▪
Wide selection
of measurement ranges
▪
Easy recalibration using the
interchangeable probes
▪
Suitable for field checking of
fixed CO2 instruments
▪
▪
Short warm-up time
Compact and versatile
106
The Vaisala CARBOCAP® Hand-Held
Carbon Dioxide Meter GM70 is a
user-friendly meter for demanding
spot measurements in laboratories,
greenhouses and mushroom farms.
The meter can also be used in HVAC
and industrial applications, and as a
tool for checking fixed CO2 instruments.
The GM70 has a short warm-up
time and is ready for use almost
immediately. It has a menu-based
interface, a graphical LCD display and
data logging capability. The optional
MI70 Link Windows® software in
combination with a USB connection
cable provides an easy way to handle
data in a PC environment.
Vaisala CARBOCAP ®
technology
The GM70 incorporates the advanced
Vaisala CARBOCAP® sensor that
has unique reference measurement
capabilities. The measurement
Two sampling methods
The handle is for hand-held
diffusion sampling. The GM70
pump enables pump-aspirated
sampling from locations difficult
to access otherwise. It is also ideal
for comparisons with fixed CO2
transmitters.
Interchangeable probes
The GM70 uses the same probes as
Vaisala CARBOCAP® Carbon Dioxide
Transmitter Series GMT220 and
Modules Series GMM220. By plugging
different probes into the handle or
pump, the user can easily change the
measurement range of the GM70.
The meter can also be used as a
calibration check instrument for
Vaisala’s GM20 and series, GMT/
M220 fixed CO2 instruments. GMP220
probes can even be adjusted by using
the GM70 meter.
The GM70 has two probe inputs.
Vaisala’s relative humidity and
dewpoint probes can also be
used simultaneously with CO2
measurement.
Technical data
CO2 volume concentration measurement
MI70 Indicator general
Measurement ranges
High concentrations
short probe (GMP221)
Menu languages
0 ... 2 %
0 ... 3 %
0 ... 5 %, 0 ... 10 %, 0 ... 20 %
Low concentrations
0 ... 2000 ppm
long probe (GMP222)
0 ... 3000 ppm, 0 ... 5000 ppm,
0 ... 7000 ppm, 0 ... 10,000 ppm
Accuracy (including repeatability, non-linearity and calibration
uncertainty) at 25 °C and 1013 hPa
GMP221
±(1.5% of range + 2% of reading)
(applies for concentrations above 2% of full scale)
GMP222
±(1.5% of range + 2% of reading)
Temperature dependence, typical
-0.3 % of reading / °C
Pressure dependence, typical
+0.15% of reading/hPa
Long-term stability
<±5 %FS/2 years
Response time (63 %)
GMP221
20 seconds
GMP222
30 seconds
Warm-up time
30 seconds, 15 minute full
specifications
Max. no. of probes
Power supply
Analog output
Output resolution
PC interface
Data logging capacity
Alarm
Operating temperature range
Operating humidity range
Housing material
Housing classification
Weight
Battery operation time
Measurement environment
Temperature
Relative humidity
Operation pressure
Flow range (diffusion sampling)
Display
English, Chinese, French, Spanish,
German, Japanese, Russian,
Swedish, Finnish
LCD with backlight, graphic trend
display of any parameter,
character height up to 16 mm
2
Rechargeable NiMH battery pack
with AC-adapter
0 ... 1 VDC
0.6 mV
MI70 Link software with USB or
serial port cable
2700 points
Audible alarm function
-10 ... +40 °C (+14 ... +104 °F)
non-condensing
ABS/PC blend
IP54
400 g
-20 ... +60 °C (-4 ... +140 °F)
0 ... 100 %RH non-condensing
700 ... 1300 hPa
0 ... 10 m/s
Continuous use
with handle
with pump
Data logging use
better than 8h at +20 °C (+68 °F)
better than 5h at +20 °C (+68 °F) without load
up to a month, depending on logging interval
Electromagnetic compatibility
EN 61326-1, Portable Equipment.
Probe, handle & pump general
Sensor
Housing material
GMP221/222 probe
GMH70 handle
GM70 Pump
Storage temperature
Storage humidity
Weight
GMH70 with GMP221/222 probe
GM70 Pump with GMP221/222
probe
Vaisala CARBOCAP®
PC plastic
ABS/PC blend
aluminium casing
-30 ... +70 °C (-22 ... +158 °F)
0 ... 100 %RH non-condensing
For more information, visit
www.vaisala.com or contact
us at [email protected]
230 g
700 g
Accessories
Connection cable for fixed CO2 instruments
GMT220, GMM220, GMD20 and
GMW20
GMA70
MI70 Link software with USB cable
219687
MI70 Link software with serial port
MI70LINK
cable
Analog output cable for 0 ... 1 VDC
27168ZZ
Calibration adapter
26150GM
Carrying case
MI70CASE
Battery, NiMH 4.8V
26755
Spare probe
GMP221, GMP222
(use the order form to define measurement range etc.)
Nafion Membrane Tubing
212807GM
Ref. B210824EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
107
Dimensions
from the stable reference provided by
the electrically tunable Fabry-Perot
Interferometer (FPI).
Features/Benefits
▪
Compact, wall-mounted
transmitter for demandcontrolled ventilation
▪
Incorporates Vaisala
CARBOCAP®, the silicon based
NDIR sensor with unique
internal referencing
▪
Advanced, single-beam, dual
wavelength measurement with
no moving parts
▪
▪
Excellent long-term stability
Ideal for ventilation control in
all types of occupied spaces
Most of us spend 90 % of our time
indoors. Consequently, good indoor
air quality is important to our
wellbeing. All human beings produce
carbon dioxide gas by respiration,
thus the carbon dioxide level can
be used as an indicator for indoor
human presence. A high CO2 level is a
sign of poor ventilation and often an
indication of other unpleasant odors
in the air. In many buildings the
ventilation need varies throughout
the day. Demand controlled
ventilation is an economical way to
ensure good air quality.
The Vaisala CARBOCAP® CO2
sensors have been proven to be
accurate and durable. They have
an excellent long-term stability,
which decreases maintenance. The
superior performance of Vaisala
CARBOCAP® sensors results largely
108
The GMW115 Transmitter is designed
especially for DCV (Demand Controlled
Ventilation) applications with two
optional CO2 measurement ranges of
0…2000 ppm and 0…5000 ppm.
60
.2
60
R2.1
Operating environment
Temperature
-5 ... +45 °C (23 ... 113 °F)
Humidity
0 ... 85 %RH
Pressure
700 ... 1200 hPa
Electromagnectic compatibility
Complies with EMS standard EN61326-1, Generic Environment
84
Inputs and outputs
Operating voltage
Power consumption
Outputs
120.9
Ø4
R3.5
The Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW115 is a wall-mounted
CO2 transmitter for demand-controlled ventilation.
The tunable FPI filter measures CO2
absorption, and simultaneously a
reference wavelength. This internal
reference measurement compensates
effectively for any changes in the
optical path, such as light source
intensity changes and contamination.
In the HVAC market, this type of
reference measurement is a unique
feature to Vaisala CARBOCAP®
products, distinguishing them
from competitors’ comparative
products that do not have a reference
measurement at all, or have an
indirect reference measurement,
which is based on an assumed background CO2 levels. In buildings with
around-the-clock occupancy (e.g.
hospitals, work-places, residential
buildings, retirement homes), the
assumed background CO2 level
reference is simply not applicable.
The true internal reference
measurement of Vaisala CARBOCAP®
CO2 transmitters provides years of
stable CO2 measurements.
66.3
124
Product lifetime
Dimensions in mm
66.7
Accuracy (including repeatability, nonlinearity and calibration uncertainty)
Long-term stability
Response time T90
Temperature dependence, typical
Pressure dependence, typical
Warm-up time
0 ... 2000 ppm
0.....5000 ppm
±(2 % of range + 2 % of
reading)
± 5 % of range/5 years
1 min
-0,35 % of reading / °C
+0,15 % of reading/hPa
1 min, 10 min for full.
specification
> 10 years
85
.3
CO2-measurement range
83.4
Performance
25.8
GMW115 Carbon Dioxide Transmitter for
Demand-controlled Ventilation
Technical data
85.2
www.vaisala.com
24 V (±20 %) AC/DC
<2 W
4 … 20 mA, 0 … 10 V,
RS-485, 2-wire, non-isolated
Housing
Material:
Colour:
Fire resistance:
Ingress protection:
ABS plastics
Cycolac 233599/NCS 0502-G50Y
UL94 HB
IP30
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210568EN-D ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
109
affected by dust, water vapor and
most chemicals.
Versatile transmitters
The GMD/W20 series transmitters
can be used independently, or
incorporated into building energy
management systems. The series
consists of duct mount units
GMD20/D and wall mount units
GMW21/D and GMW22/D. Version D
has a display. The two sizes in the
wall-mount series make them easy
to install for most standard junction
boxes.
The GMD/W20 series transmitters are designed for use in ventilation-related
applications.
Features/Benefits
▪
▪
▪
Versatile transmitters
▪
▪
Excellent long-term stability
▪
Ease of installation
Duct and wall mount models
Incorporates Vaisala
CARBOCAP® Sensor - the
silicon-based NDIR sensor
Negligible temperature
dependence
The duct mounted Vaisala
CARBOCAP® Carbon Dioxide
Transmitter Series GMD20 and
wall mounted GMW20 are specially
designed for Demand Controlled
Ventilation (DCV). They are easy to
install and require no maintenance.
The recommended calibration
interval is five years.
Vaisala CARBOCAP®
technology
The GMD/W20 Series Transmitters
use the silicon-based Vaisala
CARBOCAP® Sensor. The simple
structure and reference measurement
capabilities make this Single-Beam,
Dual-Wavelength NDIR sensor
extremely stable and reliable.
The temperature and flow
dependences of the sensor
are negligible. In addition, the
measurement accuracy is not
110
The duct units' compact sensor head
design requires only a small hole in a
ventilation duct, thereby minimizing
the risk of leaking gaskets and
measurement errors.
In addition to the standard
0 ... 20 mA, 4 ... 20 mA and 0 ... 10 V
outputs, there are three other
options: two LonWorks® interfaces
and a relay output. The relay output
is standard with the display units.
Improve indoor air at
minimal energy costs
The use of the GMD/W20 series
transmitters ensures the best
possible control of air quality and
results in considerable savings in
energy consumption, maintenance
and recalibration costs.
Temperature option
The GMA20T temperature module,
an option with the GMW21 wall
mount unit, combines both CO2 and
temperature measurement into one
transmitter. The GMA20T has an
output of 0 ... 10 V corresponding to a
temperature range of 0 ... +50 °C
(+32 ... +122 °F).
Performance
Accessories and options
CARBON DIOXIDE MEASUREMENT
Display and relay option for GMD/W21/22
Relay output option
LonWorks® module with CO2 signal
(Not available when display option is added)
LonWorks® module with both CO2 signal
and temperature signals
(Not available when display option is added)
Serial COM adapter
Analog temperature module for GMW21
(not available when display option is added)
Hand-held meter for field verification
Measurement range
0 ... 2000 ppm
(nominal; can be calibrated for other ranges:
0 ... 5000 ppm, 0 ... 10,000 ppm, 0 ... 20,000 ppm)
Accuracy (including repeatability, non-linearity
and calibration uncertainty)
± (2 % of range + 2% of reading)
Long-term stability
<±5 % of range / 5 years
Response time (63%)
1 minute
Warm-up time
1 minute, 15 minutes full specifications
TEMPERATURE MEASUREMENT (OPTIONAL WITH GMW21)
Output signal
Corresponding measurement range
Accuracy at +25 °C
Warm up time
Temperature sensor
0 ... 10V
0 ... +50 °C (+32 ... +122 °F)
±0.5 °C (0.9 °F)
30 min
Semiconductor IC
GMI21
GMR20
GML20
GML20T
19040GM
GMA20T
GM70
Dimensions
Dimensions in mm
GMD20 and GMD20D
Inputs and outputs
Outputs
Optional outputs
0 ... 20 or 4 ... 20 mA and 0 ... 10 V
relay
LonWorks® interface
8 bits
Resolution of analog outputs
Recommended external load:
current output
max. 500 ohm
voltage output
min. 1 kohm
Operating voltage
nominal 24 VAC/DC (18 ... 30 VDC)
Connections
screw terminals, wire size 0.5 ... 1.5 mm2
Power consumption
<2.5 W
80
GMW21 and GMW21D
Operating environment
Temperature
Humidity
Flow velocity (GMD20)
Electromagnetic compatibility
4 2
2 2
42
GMD/W20 Series Carbon Dioxide Transmitters
for Demand Controlled Ventilation Applications
Technical data
-5 ... +45 °C (+23 ... +113 °F)
0 ... 85 %RH, non-condensing
0 ... 10 m/s
EN61326-1, Generic Environment
60
108.5
www.vaisala.com
83
66.7
Mechanics
Housing material
ABS plastic
Housing classification (GMD20 electronics housing)
IP65
Housing colour GMW21/22
NCS 0502-G50Y
Weight:
GMD20 (D)
140 g (170 g)
GMW21 (D)
100 g (130 g)
GMW22 (D)
90 g (120 g)
GMW22 and GMW22D
60
CARBOCAP® is a registered trademark of Vaisala.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210910EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
111
Dimensions
Features/Benefits
▪
Compact, OEM module for
demand-controlled ventilation
and other CO2 measurement
applications
▪
Incorporates Vaisala
CARBOCAP®, the silicon based
NDIR sensor with unique
internal referencing
▪
Advanced, single-beam, dual
wavelength measurement with
no moving parts
▪
▪
Excellent long-term stability
Ideal for ventilation control in
all types of occupied spaces
Accuracy (including repeatability, nonlinearity and calibration uncertainty)
Long-term stability
Response time T90
Temperature dependence, typical
Pressure dependence, typical
Warm-up time
Product lifetime
0 ... 2000 ppm
0 ... 5000 ppm
0 ... 10000 ppm
± (2 % of range + 2 % of
reading
± 5 % of range/5 years
1 min
-0,35 % of reading / °C
+0,15 % of reading/hPa
1 min, 10 min for full.
specification
> 10 years
Operating environment
Temperature
-5 ... +45 °C (23 ... 113 °F)
Humidity
0 ... 85 %RH
Pressure
700 ... 1200 hPa
Electromagnectic compatibility
Complies with EMS standard EN61326-1:1997 + Am1:1998,
Generic Environment
Inputs and outputs
Operating voltage
Power consumption
Outputs
The Vaisala CARBOCAP® Carbon Dioxide Module GMM112 is a basic CO2
measurement module.
Most of us spend 90% of our time
indoors. Consequently, good indoor
air quality is important to our
wellbeing. All human beings produce
carbon dioxide gas by respiration,
thus the carbon dioxide level can
be used as an indicator for indoor
human presence. A high CO2 level is a
sign of poor ventilation and often an
indication of other unpleasant odors
in the air. In many buildings the
ventilation need varies throughout
the day. Demand controlled
ventilation is an economical way to
ensure good air quality.
The Vaisala CARBOCAP® CO2
sensors have been proven to be
accurate and durable. They have
an excellent long-term stability,
which decreases maintenance. The
112
superior performance of Vaisala
CARBOCAP® sensors results largely
from the stable reference provided by
the electrically tunable Fabry-Perot
Interferometer (FPI).
The tunable FPI filter measures CO2
absorption, and simultaneously a
reference wavelength. This internal
reference measurement compensates
effectively for any changes in the
optical path, such as light source
intensity changes and contamination.
In the HVAC market, this type of
reference measurement is a unique
feature to Vaisala CARBOCAP®
products, distinguishing them
from competitors’ comparative
products that do not have a reference
measurement at all, or have an
indirect reference measurement,
24 V (±20 %) AC/DC
<2 W
4 … 20 mA, 0 … 10 V,
RS-485, 2-wire, non-isolated
Dimensions in mm
mA
V
0
B
A
0
24V
mA
V
0
B
A
0
24V
Ø3.2
96
CO2-measurement range
25
Performance
65
GMM112 Carbon Dioxide Module
for HVAC Applications
Technical data
6
www.vaisala.com
30
60
which is based on an assumed background CO2 levels. In buildings with
around-the-clock occupancy (e.g.
hospitals, work-places, residential
buildings, retirement homes), the
assumed background CO2 level
reference is simply not applicable.
The true internal reference
measurement of Vaisala CARBOCAP®
CO2 transmitters provides years of
stable CO2 measurements.
The GMM112 Carbon Dioxide Module is
designed especially for DCV (Demand
Controlled Ventilation) applications
with three optional CO2 measurement
ranges of 0…2000 ppm, 0…5000 ppm
and 0…10000 ppm.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210567EN-D ©Vaisala 2009
This material is subject to copyright protection, with all copyrights
retained by Vaisala and its individual partners. All rights reserved.
Any logos and/or product names are trademarks of Vaisala or
its individual partners. The reproduction, transfer, distribution or
storage of information contained in this brochure in any form
without the prior written consent of Vaisala is strictly prohibited.
All specifications — technical included — are subject to change
without notice.
113
www.vaisala.com
GMM20W Carbon Dioxide Module
for OEM Applications
Features/Benefits
▪
Incorporates the silicon based
Vaisala CARBOCAP® Sensor
▪
Stable in terms of time and
temperature
▪
Dust, water vapor or most
chemicals do not affect the
measurement accuracy of the
sensor
▪
Small size enables easy
integration into various
systems
Technical data
Performance
Dimensions
CARBON DIOXIDE MEASUREMENT
Dimensions in mm
Measurement range
0 ... 2000 ppm
(nominal; can be calibrated for other ranges:
0 ... 5000 ppm, 0 ... 10,000 ppm, 0 ... 20,000 ppm)
Accuracy (including repeatability,
± (2 % of range + 2%
non-linearity and calibration uncertainty)
of reading)
Long-term stability
<±5 % of range / 5 years
Response time (63%)
1 minute
Warm-up time
minute, 15 minutes full specifications
Weight
45 g
Inputs and outputs
Outputs
Resolution of analog outputs
current output
voltage output
Operating voltage
Power consumption
0 ... 20 or 4 ... 20 mA and 0 ... 10 V
8 bits
max. 500 ohm
min. 1 kohm
nominal 24 VAC/DC (18 ... 30 VDC)
<2.5 W
Operating environment
The Vaisala CARBOCAP® Carbon Dioxide Module GMM20W is designed for OEM
applications in benign environments.
Temperature
Humidity
Electromagnetic compatibility
-5 ... +45 °C (+23 ... +113 °F)
0 ... 85 %RH, non-condensing
EN61326-1,
Generic Environment
CARBOCAP® is a registered trademark of Vaisala.
Accessories and options
Display and relay option
Relay output option
Calibration software kit
(disk and serial COM adapter)
Analog temperature module*
(not available when display option is added)
For more information, visit
www.vaisala.com or contact
us at [email protected]
114
GMI21
GMR20
19222GM
GMA20T
Ref. B210939EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
115
www.vaisala.com
GML20 and GML20T
LonWorks® Options for GMD/W20 Series
Technical data
Features
t -PO8PSLT® interoperable
t 5XJTUFEQBJSGSFFUPQPMPHZOFUXPSLUZQF51'5BULCQT
t "EEJUJPOBMUXPXJSFTOFFEFEGPSQPXFSJOHUIFUSBOTNJUUFSDBO
thus be connected to both powered and non-powered networks
t 4FSWJDFCVUUPOBOETFSWJDF-&%GPSTJNQMFJOTUBMMBUJPOBOE
configuration
t &YUFSOBMJOUFSGBDFYJG
GJMFBWBJMBCMFPOSFRVFTU(.-
part no. 19412GM, GML20T part no. 19748GM)
t 5FNQFSBUVSF(.-5POMZ
.FBTVSFNFOUBDDVSBDZ
0.5 °C (0.9 °F) Measurement range 0 ... +45 °C (+32 ... 113 °F)
Warm-up time 30 min.
Network Variables for CO2
(BOTH MODELS GML20 AND GML20T)
GML20 (left) and GML20T modules
enable digital communication between
the Vaisala CARBOCAP® Carbon
Dioxide Transmitter Series GM20 and a
LonWorks® network.
GML20T module connects a Vaisala CARBOCAP® Carbon Dioxide Transmitter
GMW21 to a LonWorks® network.
Significant savings
Vaisala's GML20 and GML20T are
interface modules for distributing
signals from Vaisala CARBOCAP®
Carbon Dioxide Transmitter Series
GM20 digitally to a LonWorks®
network over a twisted pair.
Features/Benefits
▪
Enables digital communication
between Vaisala CARBOCAP®
▪
Carbon Dioxide Transmitter
Series GM20 and LonWorks®
▪
▪
▪
GML20 for CO2 signal
116
GML20T for CO2 + T signal
Savings in cabling, installation
and maintenance costs
The GML20 Module distributes
CO2 signals; the GML20T Module
distributes both CO2 and temperature
signals. The GML20T Module can
be used only with the Vaisala
CARBOCAP® Carbon Dioxide
Transmitter GMW21.
The use of these modules and
Vaisala CARBOCAP® Carbon Dioxide
Transmitter Series GM20 with a
LonWorks® networked control
system contributes to considerable
savings in cabling, installation and
maintenance costs.
Intelligent LonTalk®
protocol
In a LonWorks® network, devices
called nodes communicate with each
other using the LonTalk ® protocol.
Every node consists of a Neuron®
chip and a transceiver. The Neuron®
chip is a microprocessor which
contains an application program and
LonTalk ® protocol. The transceiver
adapts the Neuron® chip into the
hardware environment used. The
nodes communicate with each other,
sending messages containing the
value of the desired variables.
With Vaisala modules, these
variables are CO2 (GML20) or CO2
and temperature (GML20T). Some
network variables are so-called
configuration variables, which are
used to define the behavior of the
node. With the GML20 and GML20T,
they are used to designate how much
the temperature and/or carbon
dioxide level must change before a
measured value is sent again.
nviRequest: to request modes for objects within this node
nvoStatus: to report status of objects on this node
nvoCO2ppm: this output variable reports the CO2 level detected by
the sensor
nciMaxSendtime: indicates the maximum period of time that
expires before the sensor object automatically updates all its
output variables (default value: 300 seconds)
nciMinSendtime: indicates the minimum period between output
network variable transitions (default value: 5 seconds)
nciCO2MinDelta: indicates the minimum CO2 level change
required to update the output network variables
(default value: 10 ppm)
Networks Variables for Temperature
(GML20T MODEL ONLY)
nvoHVACtemp: this output variable reports the temperature
detected by the sensor
nciMaxStime_temp: indicates the maximum period of time that
expires before the sensor object automatically updates all its
output variables (default value: 300 seconds)
nciMinStime_temp: indicates the minimum period between
output network variable transitions (default value: 5 seconds)
nciMinDelta_temp: indicates the minimum temperature change
required to update the output network variables
(default value: 0.3 °C)
nciTmpOffset: indicates the temperature offset level
(default value: -0.8 °C)
LonWorks® is a registered trademark of Echelon Corporation.
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210943EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
117
Oxygen
www.vaisala.com
OMT355 Oxygen Transmitter for Industrial
Process Measurements
Low maintenance
A stainless steel mesh filter and an
optional porous PTFE filter protect
the OMT355 probe optics from dust
and dirt. An intelligent measurement
algorithm further minimizes
contamination effects and provides
a maintenance alert well before
the measurement performance is
affected.
gases injected through an optional
calibration gas connector. The
calibration interval of the OMT355 is
12 months.
User friendly interfaces
For calibration and configuration, the
OMT355 features both software and
keypad user interfaces and an LCD
display.
Long calibration interval
TDL Technology
Calibration or field checking of
the instrument can be done either
with ambient air or with zero/span
The Tunable Diode Laser
(TDL) technology used in the
SPECTRACAP® sensor is one of the
most powerful technologies in gas
measurement on the market today.
The technology is based on
measuring the attenuation of a beam
of laser light in the sample gas. For
oxygen sensing the laser is tuned to
a wavelength which is characteristic
and unique for the oxygen molecule.
Therefore, the measured attenuation
is an extremely selective measure for
the amount of oxygen on the path of
the laser beam.
OMT355 with the sampling cell.
Technical data
The Vaisala SPECTRACAP® Oxygen Transmitter.
Features/Benefits
▪
Minimizes need for sample
conditioning equipment
▪
In-situ probe or sampling cell
options
▪
▪
Tolerates aggressive chemicals
▪
▪
Low maintenance
▪
Heated optical surfaces to
prevent condensation
▪
Typical applications:
Tolerates excessive amounts of
moisture even in liquid form
Diagnostic output for
preventive maintenance
đŏ #/ŏ#!*!.0%+*
đŏ #/ŏ(*'!0%*#
đŏ "!.)!*00%+*
đŏ +),+/0%*#ŏ,.+!//ŏ
monitoring
118
The Vaisala SPECTRACAP® Oxygen
Transmitter OMT355 is ideal for
oxygen monitoring in moist and
aggressive process gases. Typical
applications include gas generation,
inert gas blanketing, fermentation
and composting process monitoring.
Laser based measurement
The Vaisala SPECTRACAP®
Oxygen Transmitter OMT355 is
ideal for oxygen monitoring in
moist and aggressive process
gases.The OMT355 incorporates
a compact tunable diode laser
(TDL) gas spectrometer built in the
measurement probe. This optical
measurement technology is well
known for unmatched stability and
robustness. The SPECTRACAP®
sensor offers TDL technology in a
compact probe suitable for field use.
Direct installation
In many applications, the OMT355
can be flange-mounted directly into
a process. No sampling or sample
conditioning equipment is needed.
This feature provides real time
measurement data without sampling
or sample switching delays.
Sampling cell installation
An optional sampling cell is
available for processes with high
temperatures, elevated pressures
or extremely difficult mechanical
conditions. Due to the robustness of
the SPECTRACAP® sensor and its low
sensitivity to gas flow and pressure
variations, the sampling system can
be very simple and it can be installed
near the sampling point.
Performance
Operating Environment
Measurement range
0 ... 100 % O2
Accuracy
±0.2 % O2
(including noise, linearity, and repeatability)
Temperature dependence over T range
±2 % of reading
Stability
±1 % of reading/yr
Zero drift
±0.1 % O2/yr
Response time of measurement
3s
Diffusion limited response in still air
T63/T90
without filters
10 s / 20 s
with stainless steel mesh filter
10 s / 25 s
with stainless steel mesh and PTFE filters
30 s / 70 s
Pressure dependence without pressure compensation
0.8 ... 1.2 bar
-2 % of reading
1.2 ... 1.4 bar
-5 % of reading
Accuracy of pressure compensation
±0.25 % of reading
Background gas effects for CO2 and H2O, uncompensated
<1 % of reading for <6 vol-% CO2
<1 % of reading for gas dewpoint < 30 °C
Accuracy of background gas compensation
±0.5 % of reading
0 ... 50 vol-% CO2
0 ... 300 g/m3 H2O (Td = 80 °C)
±1 % of reading
Operating temperature range
for probe (in-line installation)
-20 ... +80 °C
for electronics (housing)
-40 ... +60 °C
for transmitter (ambient gas measurement)
-20 ... +60 °C
Storage temperature range
-55 ... +80 °C
Operating pressure range
0.8 ... 1.4 bar
Maximum pressure range for probe
up to 10 bar
Compliance
IEC(EN)-61326 Electrical equipment for measurement, control
and laboratory use. EMC requirements
EN50104 Electrical apparatus for the detection and
measurement of oxygen. Performance requirements and test
methods.
EN50271 Electrical Apparatus for the Detection and
Measurement of Combustible Gases, Toxic Gases or Oxygen
Laser safety
Class 1 laser product
Inputs and Outputs
Power supply
input range
Power consumption
maximum
typical
Analog output
maximum load
Serial output (2-wire, non-isolated)
Alarm/control relay
11 ... 36 VDC
6W
3W
0/4 ... 20 mA, sourcing
500 Ω
RS-485
30 VAC/60 VDC
119
Technical data
Mechanics
Dimensions
Housing material
G-AlSi10 Mg (DIN 1725)
Probe material
AISI 316
Housing classification
IP66
Dimensions
306 mm x 184 mm x 74 mm
Weight
2.2 kg
Mounting flange diameter
97 mm
Can be fitted to standard flanges. Minimum sizes:
DIN (2527B) DN50 and ANSI (150) 2.5"
Cable bushing
Cable gland M20 x 1.5
Stainless steel mesh filter
openings ø 310 μm
Wetted materials
AISI 316, EPDM or Kalrez® (optional), PTFE (optional), SiN, MgF2
Dimensions in mm
306 mm x 184 mm x 74 mm
Options and accessories
Hydrophobic PTFE filter, pore size 8 μm
with EPDM O-rings
with Kalrez® O-rings
1/2" NPT conduit fitting
M12 male 8-pin connector for user cable
Serial interface cable for PC
USB-RJ45 Serial interface cable
Sample cell with wall mounting bracket
with EPDM O-rings
with Kalrez® O-rings
217055
217056
217197
214806SP
19446ZZ
219685
217052
216619
For complete specifications, refer to the User’s Guide.
SPECTRACAP® is a registered trademark of Vaisala.
Humidity and
CO2 Measurement
for Critical
Environments
For over 70 years Vaisala has provided RELIABLE measurements, helping you meet SPECIFICATIONS and allowing you to
focus on your business. Our products are supported by our local
experts, so you can have CONFIDENCE when it MATTERS.
Take a look at useful knowledge items
at www.vaisala.com/lifescience
For more information, visit
www.vaisala.com or contact
us at [email protected]
120
Ref. B210623EN-C ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
www.vaisala.com
121
www.vaisala.com
OMT364 Oxygen Transmitter for
Hazardous Areas
The Vaisala SPECTRACAP® Oxygen Transmitter OMT364 for hazardous areas.
Features/Benefits
▪
Minimizes need for sample
conditioning equipment
▪
▪
▪
In-situ probe or sampling cell
▪
▪
▪
Low maintenance
▪
Example applications:
fermentation, composting
process monitoring, inerting
processes and flare gas
recovery
Tolerates aggressive chemicals
Tolerates excessive amounts of
moisture even in liquid form
Calibration interval 12 months
+"03.!ŏ* ŏ'!5, ŏ1/!.ŏ
interfaces and an LCD display
The Vaisala SPECTRACAP® Oxygen
Transmitter OMT364 is designed
for oxygen monitoring in moist and
aggressive process gases.
Laser based measurement
The OMT364 incorporates a
compact tunable diode laser (TDL)
gas spectrometer built in the
measurement probe. This optical
measurement technology is well
known for unmatched stability
and robustness. The patented
SPECTRACAP® sensor offers uniquely
TDL technology in a compact probe
suitable for field use.
FM Approved OMT364 for
Hazardous Areas
The non-incendive OMT364
transmitter is permitted for use in
Class I, Division 2 of the NEC® 500
area classification according to FM
Approvals SM . The probe of the
122
instrument can be installed in areas
that are classified as Class I, Division
1 or 2.
Direct installation
In many applications, the OMT364
can be flange-mounted directly into
a process. No sampling or sample
conditioning equipment is needed.
This feature provides real time
measurement data without sampling
or sample switching delays.
Sampling cell installation
An optional sampling cell is
available for processes with high
temperatures, elevated pressures
or extremely difficult mechanical
conditions. Due to the robustness of
the SPECTRACAP® sensor and its low
sensitivity to gas flow and pressure
variations, the sampling system is
simple and it can be installed near
the sampling point.
Technical data
Performance
Classification
Measurement range
0 ... 100 % O2
Accuracy (including noise, linearity and
repeatability)
±0.2 % O2
Temperature range over T range
±2 % of reading
Stability
±1 % of reading/yr
Zero drift
±0.1 % O2/yr
Response time of measurement
3s
Diffusion limited response in still air
T63/T90
without filters
10 s / 20 s
with stainless steel mesh filter
10 s / 25 s
with stainless steel mesh filter and
PTFE filters
30 s / 70 s
Pressure dependence without pressure
compensation
0.8 ... 1.2 bar
-2 % of reading
1.2 ... 1.4 bar
-5 % of reading
Accuracy of pressure compensation
±0.25 % of reading
Background gas effects for CO2 and H2O uncompensated
< 1% of reading for <6 vol -% CO2
< 1% of reading for gas dew point < 30 ˚C
Accuracy of background gas compensation
±-0.5 % of reading
0 ... 50 vol-% CO2
0 ... 300 g/m3 H2O (Td=80 ˚C)
±1 % of reading
OMT364 CLASSIFICATIONS FOR THE TRANSMITTER
Operating environment
Operating temperature range for
probe (in-line installation)
-20 ... +80 ˚C
-20 ... +60 ˚C
electronics (housing) (Kalrez® seals)
transmitter (ambient gas
measurement)
-20 ... +60 ˚C
Storage temperature range
-55 ... +80 ˚C
Operating pressure range
0.8 ... 1.4 bar
Maximum pressure range for probe
up to 10 bar
Compliance
IEC(EN)-61326 Electrical equipment for measurement,
control and laboratory use. EMC requirements.
Laser safety
Class 1 laser product
For more information, visit
www.vaisala.com or contact
us at [email protected]
USA and Canada
FM, Non-incendive for Class I,
Division 2, Groups A, B, C, and D.
Ta = -20 ˚C to +60 ˚C
OMT364 CLASSIFICATIONS FOR THE PROBE
USA and Canada
FM, Suitable for Class I, Division 1,
Groups A, B, C, and D.
Ta = -20 ˚C to +80 ˚C
Inputs and outputs
Power supply
input range
Power consumption
maximum
typical
Analog output
maximum load
Serial output (2-wire, non-isolated)
Alarm/control relay
11 ... 36 VDC
6W
3W
0/4 ... 20 mA sourcing
500 Ω
RS-485
30 VAC/60 VDC
Mechanics
Housing material
Probe material
Housing classification
Weight, transmitter and probe
Weight, sample cell
Mounting flance diameter
Cable bushing
Stainless steel mesh filter
Wetted materials
AISI 316, Kalrez®, PTFE (optional),
SiN, MgF2
G-AlSI10 Mg (DIN 1725)
AISI 316
IP66
2.2 kg
2.6 kg
97 mm
Cable gland M20 x 1.5
openings ø 310 μm
Options and accessories
Hydrophobic PTFE filter, pore size 8 μm with
Kalrez® O-rings
1/2” NPT conduit fitting
Sample cell with wall-mounting bracket
gas fittings for O.D. 6 mm tube
volume 260 m3
T63 response time with 1 l/min
sample flow and mesh filter, 18 s
with Kalrez® O-rings
217056
217917
216619
Ref. B210823EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
123
Barometric Pressure
www.vaisala.com
PTU300 Models
PTU300 Combined Pressure, Humidity and
Temperature Transmitter for demanding applications
Dimensions in mm (inches)
120 (4.72)
12 (0.47)
allowing users to easily monitor
operational data, measurement
trends and 1-year measurement
history. The optional data logger
with real-time clock makes it
possible to generate over four years
of measured history, and zoom in
on any desired time or time frame.
The battery backup of the real-time
clock guarantees a reliable logging of
measured data.
Dimensions
PTU301 for wall mounting
The display alarm allows tracking
of any measured parameter, with a
freely configurable low and high limit.
Dimensions
Dimensions in mm (inches)
183 (7.20)
Barometric pressure, humidity
and temperature measurement
in one transmitter
▪
Available with two barometric
pressure sensors – added
reliability
▪
RS-232C serial interface with
NMEA protocol for GPS use
▪
Optional display, RS-485,
analog output, and relay
▪
▪
▪
Optional power supply module
▪
Applications include
environmental monitoring
in calibration laboratories,
GPS meteorology: estimating
precipitable water vapor in the
atmosphere; weather stations
NIST traceable calibration
HMT330MIK Installation kit for
outdoor use
The Vaisala Combined Pressure,
Humidity and Temperature
Transmitter PTU300 measures
barometric pressure in two accuracy
classes, humidity, and temperature.
You can choose which probe
best suits your needs: PTU301 for
laboratories, PTU303 for outdoor
use, the warmed PTU307 probe for
demanding meteorology, and PTU30T
for pressure and temperature only.
Vaisala proven sensor
technology
The PTU300 transmitter uses sensors
known for their high accuracy
and excellent long-term stability:
the Vaisala BAROCAP® is used for
pressure measurement and the
Vaisala HUMICAP® for humidity
measurement. The temperature
sensor is a platinum RTD sensor.
Graphical trend display
124
The PTU300 series features a large
numerical and graphical display,
PTU301 short cable probe
A USB-RJ45 cable makes it easy
to connect the service port of the
PTU300 to a PC.
42 (1.65)
Flexible calibration
A quick, one-point field calibration for
humidity can easily be done using the
Vaisala Hand-Held Humidity Meter
HM70.
Dimensions
Dimensions in mm (inches)
Serial communication
The PTU300 comes with a standard
RS-232 serial interface. The output
format is compatible with major GPS
receivers and NMEA coded messages.
RS-485 is available as an option.
M9x1
▪
One transmitter, three
measurements
106 (4.17)
Features/Benefits
The recorded measurement data
can be viewed on the display or
transferred to a PC with Microsoft
Windows® software. The transmitter
can also be connected to a network
with an optional (W)LAN interface,
which enables a (wireless) Ethernet
connection.
Ø 12 (0.47)
The Vaisala PTU300 Combined Pressure, Humidity and Temperature Transmitter is a
versatile, multi-purpose instrument.
116 (4.57)
Data collection and
(wireless) transfer to PC
37.5 (1.48)
PTU303 for outdoor use
78.5 (3.09)
98.5 (3.88)
Outdoor installation kit
The optional HMT330MIK Installation
Kit is available for outdoor
installation. It provides reliable
measurements for meteorological
purposes.
125
PTU300 Models
Technical data
Dimensions
Performance
Dimensions in mm (inches)
BAROMETRIC PRESSURE
79.5 (3.13)
PTU307 warmed probe for demanding
meteorological installations
Ø 6 (0.24)
Ø 3.2 (0.13)
99.5 (3.92)
130 (5.12)
Dimensions
Ø 6 (0.24)
Ø 3.2 (0.13)
Dimensions in mm (inches)
130 (5.12)
CLASS A
CLASS B
Linearity
±0.05 hPa
±0.10 hPa
±0.20 hPa
Hysteresis*
±0.03 hPa
±0.03 hPa
±0.08 hPa
Repeatability*
±0.03 hPa
±0.03 hPa
±0.08 hPa
Calibration
±0.07 hPa
±0.15 hPa
±0.20 hPa
uncertainty**
Accuracy at +20 °C*** ±0.10 hPa
±0.20 hPa
±0.30 hPa
Temperature
±0.1 hPa
±0.1 hPa
±0.3 hPa
dependence****
±0.15 hPa
±0.25 hPa
±0.45 hPa
Total accuracy
(-40 ... +60 °C/
-40 ... +140 °F)
Long-term stability/year ±0.1 hPa
±0.1 hPa
±0.2 hPa
Response time
(100 % response)
one sensor
2 st
1 st
1 st
Pressure units
hPa, mbar, kPa, Pa, inHg, mmH20, mmHg, torr, psia
37.5 (1.48)
PTU30T for pressure and temperature
only measurement
500 ... 1100 hPa, 50 ... 1100 hPa
500 ... 1100 hPa 500 ... 1100 hPa 50 ... 1100 hPa
M9x1
Ø 12 (0.47)
Pressure range
Accuracy
*
Defined as ±2 standard deviation limits of endpoint non-linearity,
hysteresis error or repeatability error and calibration.
** Defined as ±2 standard deviation limits of accuracy of the working
standard including traceability to NIST.
*** Defined as the root sum of the squares (RSS) of endpoint non-linearity,
hysteresis error, repeatability error and calibration uncertainty at room
temperature.
**** Defined as ±2 standard deviation limits of temperature dependence over
the operating temperature range.
ACCURACY OVER TEMPERATURE RANGE
Δ °C
0.5
0.4
0.3
0.2
0.1
°C
0
-0.1
-0.2
-0.3
-0.4
-0.5
-40
-20
0
20
Temperature sensor
40
60
PT100 RTD 1/3 Class B IEC 751
RELATIVE HUMIDITY
Measurement range
Accuracy (including non-linearity,
hysteresis, and repeatability at
+15 ... +25 °C
0 ... 100 %RH
±1 %RH (0 ... 90 %RH)
±1.7 %RH (90 ... 100 %RH)
at -20 ... +40 °C
±(1.0 + 0.008 x reading) %RH
at -40 ... +60 °C
±(1.5 + 0.015 x reading) %RH
Factory calibration uncertainty (+20 °C )
± 0.6 %RH (0 ... 40 %RH)
(Defined as ±2 standard deviation
± 1.0 %RH (40 ... 97 %RH)
limits. Small variations possible,
see also calibration certificate.)
Sensor
for typical applications
Vaisala HUMICAP® 180 or 180R*
for applications with chemical
purge/warmed probe
Vaisala HUMICAP® 180C or 180RC*
Response time (90 %) at +20 °C (+68 °F) in still air
with grid filter
8 s / 17 s*
with grid + steel netting filter
20 s / 50 s*
with sintered filter
40 s / 60 s*
* with HUMICAP® 180R or 180RC sensor
TEMPERATURE
Measurement range, all probes
Accuracy at +20 °C (+68 °F)
Temperature units
126
The display also shows the WMO pressure
trend ΔP 3h and tendency of 0 ... 9.
-40 ... +60 °C (-40 ... +140 °F)
± 0.2 °C (± 0.4 °F)
°C, °F
Operating Environment
Operating temperature
with display
Humidity range
Electromagnetic compatibility
-40 ... +60 °C (-40 ... +140 °F)
0 ... +60 °C (+32 ... +140 °F)
non-condensing
EN61326-1:1997 + Am1:1998
+Am2:2001; Industrial Environment
Inputs and outputs
Operating voltage
10 ... 35 VDC, 24 VAC
with optional power supply module
100 ... 240 VAC, 50/60 Hz
Power consumption at +20 °C (Uin 24 VDC)
RS-232
max. 28 mA
Uout 3 x 0 ... 1 V/0 ... 5 V/0 ... 10 V
max. 33 mA
max. 63 mA
Iout 3 x 0 ... 20 mA
display and backlight
+20 mA
during chemical purge
max. +110 mA
during probe heating
+120 mA
Settling time at power-up (one sensor)
class A
4s
class B
3s
External loads
current outputs
RL < 500 ohm
0 ... 1 V output
RL > 2 kohm
0 ... 5 V and 0 ... 10 V outputs
RL > 10 kohm
127
Mechanics
Cable bushing
M20 x 1.5 for cable diameter
8 ... 11 mm/0.31 ... 0.43"
Conduit fitting
1/2" NPT
User cable connector (optional)
M12 series 8-pin (male)
option 1
female plug with 5 m (16.4 ft) black cable
option 2
female plug with screw terminals
Probe cable diameter
PTU303
6.0 mm
other probes
5.5 mm
Housing material
G-AlSi 10 Mg (DIN 1725)
Housing classification
IP 65 (NEMA 4)
Weight
depending on selected probe
1.5 ... 2.0 Kg
Accessories
PC software and cable
USB-RJ45 Serial Connection Cable
Connection cable for HM70
Wall mounting plate (plastic)
Pole installation kit
Rain shield
DIN rail installation set
Duct installation kit, PTU303/307
Cable gland and AGRO, PTU303/307
Solar radiation shield, PTU303/307/30T
Meteorological installation kit
Duct installation kit (T probe)
215005
219685
211339
214829
215108
215109
211477
210697
HMP247CG
DTR502B
HMT330MIK
215003
Dimensions
Dimensions in mm (inches)
96 (3.78)
Ø 7 (0.28)
116 (4.57)
183 (7.20)
169 (6.65)
Reliable and accurate
HVAC solutions
77 (3.03)
71 (2.80)
Recommended wire size
0.5 mm2 (AWG 20) stranded wires
Digital outputs
RS-232, RS-485 (optional)
Service connection
RS-232, USB
Relay outputs (optional)
0.5 A, 250 VAC
Ethernet interface (optional)
Supported standards
10/100Base-T
Connector
RJ45
Protocols
Telnet
Software support
Vaisala MI70 link
WLAN interface (optional)
Supported standards
802.11b
Antenna connector type
RP-SMA
Protocols
Telnet
Security
WEP 64/128,WPA
Software support
Vaisala MI70 link
Authentication / Encryption (WLAN)
Open / no encryption
Open / WEP
WPA Pre shared key / TKIP
WPA Pre shared key / CCMP (a.k.a. WPA2)
Optional data logger with real-time clock
Logged parameters
max. three with trend/min/max values
Logging interval
10 sec (fixed)
Max. logging period
4 years 5 months
Logged points
13.7 million points per parameter
Battery lifetime
min. 5 years
Display
LCD with backlight, graphic trend display
of any parameter
Menu languages
English, Finnish, French, German, Japanese,
Chinese, Spanish, Swedish, Russian
Analog outputs (optional)
current output
0 ... 20 mA, 4 ... 20 mA
voltage output
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
Humidity and temperature
accuracy at +20 °C
±0.05% full scale
temperature dependence
±0.005%/°C full scale
Pressure
500 ... 1100 hPa
50 ... 1100 hPa
accuracy at +20 °C
±0.30 hPa
±0.40 hPa
accuracy at -40 ... +60 °C
±0.60 hPa
±0.75 hPa
BAROCAP® and HUMICAP® are registered
trademarks of Vaisala.
/ HUMIDITY & CO2
TYPE APPROVED PRODUCT
CERTIFICATE NO.: A-11440
For more information, visit
www.vaisala.com or contact
us at [email protected]
128
Ref. B210954EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
www.vaisala.com/hvac
129
www.vaisala.com
PTB330 Digital Barometer for Professional
Meteorology, Aviation, and Industrial Users
against one another and provides
information on whether these are
within the set internal difference
criteria. This unique feature
provides redundancy in pressure
measurement.
Vaisala BAROCAP® Digital Barometer PTB330 with a new trend display.
Vaisala BAROCAP® Digital Barometer
PTB330 is a new generation
barometer, designed for a wide
range of high-end atmospheric
pressure measurement. The pressure
measurement of the PTB330 is based
on the Vaisala in-house, silicon
Features/Benefits
capacitive, absolute pressure sensor
- the Vaisala BAROCAP® Sensor. It
provides high measurement accuracy
and excellent long-term stability.
Highly accurate
The PTB330 series is highly accurate.
The Class A barometers for the
most demanding applications are
fine-tuned and calibrated against a
high-precision pressure calibrator.
Class B barometers are adjusted and
calibrated using electronic working
standard. All the PTB330 barometers
come with a NIST traceable, factory
calibration certificate.
▪
▪
▪
▪
Vaisala BAROCAP® sensor
▪
Graphical trend display with
1-year history data
Reliability through
redundancy
▪
Height and altitude corrected
pressure (QFE, QNH)
▪
For professional meteorology
and aviation, laboratories,
demanding industrial
applications
According to customers’ choice, the
PTB330 can incorporate one, two
or three BAROCAP® sensors. When
two or three sensors are used, the
barometer continuously compares
the readings of the pressure sensors
Accurate measurement
Excellent long-term stability
Added reliability through
redundancy
130
Technical data
Performance
Inputs and outputs
BAROMETRIC PRESSURE RANGE 500 ... 1100 hPa
Linearity*
Hysteresis*
Repeatability*
Calibration uncertainty**
Accuracy at +20 °C (+68 °F) ***
Class B
±0.20 hPa
±0.08 hPa
±0.08 hPa
±0.15 hPa
±0.20 hPa
Linearity*
Hysteresis*
Repeatability*
Calibration uncertainty**
Accuracy at +20 °C ***
QNH and QFE
TEMPERATURE DEPENDENCE****
Graphical display
The PTB330 features a multi-lingual,
graphical display allowing users to
monitor measurement trends. The
graph is updated automatically while
measuring and it provides a one-year
measurement history. In addition to
instant pressure, the PTB330 also
provides the WMO pressure trend
and tendency codes.
Class B
±0.10 hPa
±0.03 hPa
±0.03 hPa
±0.15 hPa
±0.20 hPa
BAROMETRIC PRESSURE RANGE 50 ... 1100 hPa
Thus, users also get a stable and
reliable pressure reading at all times
as well as a pre-indication of when to
service or recalibrate the barometer.
The PTB330 can be set to
compensate for QNH and QFE
pressure used especially in aviation.
The QNH represents the pressure
reduced to sea level, based on the
altitude and temperature of the
observation site. The QFE represents
the height corrected pressure of
small differences in altitude, for
example, the air pressure at the
airfield elevation.
Class A
±0.05 hPa
±0.03 hPa
±0.03 hPa
±0.07 hPa
±0.10 hPa
500 ... 1100 hPa
50 ... 1100 hPa
±0.1 hPa
±0.3 hPa
TOTAL ACCURACY -40 ... +60 °C (-40 ... +140 °F)
Class A
±0.15 hPa
500 ... 1100 hPa
50 ... 1100 hPa
Class B
±0.25 hPa
±0.45 hPa
LONG-TERM STABILITY
500 ... 1100 hPa
±0.1 hPa/year
50 ... 1100 hPa
±0.1 hPa/year
* Defined as ±2 standard deviation limits of endpoint non-linearity,
hysteresis or repeatability error.
** Defined as ±2 standard deviation limits of inaccuracy of the
working standard including traceability to NIST.
*** Defined as the root sum of the squares (RSS) of endpoint
non-linearity, hysteresis error, repeatability error and calibration
uncertainty at room temperature.
**** Defined as ±2 standard deviation limits of temperature
dependence over the operating temperature range.
Supply voltage
10 ... 35 VDC
Supply voltage sensitivity
negligible
Typical power consumption at +20 °C
(Uin 24 VDC, one pressure sensor)
RS-232
25 mA
RS-485
40 mA
25 mA
Uout
40 mA
Iout
display and backlight
+20 mA
Serial I/O
RS232C, RS485/422
Pressure units
hPa, mbar, kPa, Pa inHg, mmH20, mmHg, torr, psia
Class A
Class B
Resolution
0.01 hPa
0.1 hPa
Settling time at power-up (one sensor)
4s
3s
Response time (one sensor)
2s
1s
Acceleration sensitivity
negligible
Pressure connector
M5 (10-32) internal thread
Pressure fitting
barbed fitting for 1/8” I.D. tubing or quick
connector with shutoff valve for 1/8” hose
Maximum pressure limit
5000 hPa abs.
Compliance
EMC standard EN61326-1:1997 + Am1:1998 +
Am2:2001: Industrial Environment
Mechanics
Housing material
Housing classification
Weight
G AlSi10 Mg (DIN 1725)
IP66
1 - 1.5 kg
Analog output (optional)
Current output
Voltage output
Accuracy at pressure range
at +20 °C
at -40 ... +60 °C
0 ... 20 mA, 4 ... 20 mA
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
500 ... 1100 hPa
50 ... 1100 hPa
±0.30 hPa
±0.40 hPa
±0.60 hPa
±0.75 hPa
Operating environment
Pressure range
Temperature range
operating
with local display
500 ... 1100 hPa, 50 ... 1100 hPa
-40 ... +60 °C (-40 ... +140 °F)
0 ... +60 °C (+32 ... +140 °F)
Applications
Data transfer software
The PTB330 can be used successfully
for aviation, professional
meteorology, and for demanding
industrial pressure measurement
applications such as accurate laser
interferometric measurement and
exhaust gas analysis in engine test
benches.
MI70 Link Interface Software
Requirement:
Microsoft® Windows OS
Microsoft® Excel
For more information, visit
www.vaisala.com or contact
us at [email protected]
Accessories
Serial interface cable
USB-RJ45 serial connection cable
Software interface kit
Wall mounting kit
Outdoor installation kit (weather shield)
Installation kit for pole or pipeline
Power supply module
Temperature compensated analog output module
Isolated RS-485 module
19446ZZ
219685
215005
214829
215109
215108
POWER-1
AOUT-1T
RS485-1
Ref. B210708EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
131
www.vaisala.com
Take the lab to the field
Vaisala Barometric Pressure Transfer
Standard PTB330TS
The PTB330 Digital Barometer
The HMP155 probe
The MI70 hand-held indicator displaying
the prevailing pressure in hPa
includes a PTB330 digital
PTB330 Digital barometer
barometer, hand-held MI70
Vaisala BAROCAP® Digital Barometer
PTB330 is a new generation
barometer designed for a wide
range of high-end atmospheric
pressure measurement. The pressure
measurement of the PTB330 is based
on the Vaisala in-house, silicon
capacitive, absolute pressure sensor
– the Vaisala BAROCAP® Sensor. It
provides high measurement accuracy
and excellent long-term stability.
against one another and provides
information on whether these are
within the set internal difference
criteria. This unique feature
provides redundancy in pressure
measurement. Thus, users get a
stable and reliable pressure reading
at all times as well as a pre-indication
of when to service or re-calibrate the
barometer.
probe for the HMP155 is ideal for
measurement in environments with
rapidly changing temperatures.
Operational PTB330TS unit
indicator, optional HMP155
humidity and temperature
probe, optional MI70 Link
PC software, a user’s guide
and a weatherproof transfer
case equipped with a
shoulder strap.
PTB330TS transport case
High accuracy
Barometric Pressure Transfer
Standard PTB330TS makes field
inspection accurate and easy. It
combines a PTB330 digital barometer
with a hand-held MI70 indicator
within a portable unit functioning
as a transfer standard. The optional
HMP155 probe is available for
accurate humidity and temperature
measurement.
The PTB330TS is suitable for various
reference measurements in industrial
and meteorological areas.
The PTB330TS comes in a durable
and weatherproof transport case
that can be easily carried and
shipped. The components are placed
in a proofing foam interior, with
accessories and user’s guide placed
in the lid organizer. The case includes
a separate inner tabletop case in
which the barometer is mounted.
Shoulder strap is included for
convenience. Battery duration is up
to 11 hours of continuous use and up
to 30 days in data logging use.
Features / Benefits
▪
Portable, battery operated
transfer standard with data
logging capability
▪
Optional humidity and
temperature measurents
with HMP155
▪
Data can be logged, and
transferred to a PC via
MI70Link software
Barometric pressure with Vaisala
BAROCAP® Digital Barometer
PTB330
– Vaisala HUMICAP®180R sensor superior long-term stability
▪
SO/IEC 17025 Accredited
calibration services available
– New, fast temperature probe
– Excellent long term stability
▪
– Chemical purge
For professional meteorology,
aviation, laboratories and
demanding industrial
applications
– Accurate measurents
– Added reliability through
redundancy
132
▪
▪
Multilingual user interface,
nine languages
The PTB330 series features extremely
high accuracy. Class A barometers for
the most demanding applications are
fine-adjusted and calibrated against
a high-precision pressure calibrator.
All the PTB330 barometers come with
a NIST traceable, factory calibration
certificate, also optional ISO/IEC
17025 accreditation calibration
services are available.
Reliability through
redundancy
According to customers’ choice, the
PTB330 can incorporate one, two
or three BAROCAP® sensors. When
two or three sensors are used, the
barometer continuously compares
the readings of the pressure sensors
Optional HMP155
Humidity and
temperature probe
The new Vaisala HUMICAP® Humidity
and Temperature Probe HMP155
provides reliable humidity and
temperature measurement.
Long-term stability
The HMP155 has a new generation
Vaisala HUMICAP®180R sensor
that has excellent stability and
withstands harsh environments well.
The probe structure is solid and the
sensor is protected with a sintered
teflon filter, which gives maximum
protection against liquid water, dust,
and dirt.
Fast temperature
measurement
MI70 Hand-held indicator
for spot-checking
applications
The Vaisala Measurement Indicator
MI70 is a user-friendly indicator
for demanding spot-checking
measurements. It is ideal for field
checking and calibration of Vaisala’s
fixed instruments.
Easy-to-use user interface
and three-variable display
The MI70 features a multilingual,
menu-based user interface, and a
clear graphical LCD display. Overall
three measurement parameters can
be displayed and logged into the
meter’s memory at the same time.
One or two probes or transmitters
can be connected simultaneously.
MI70 Link
The optional MI70 Link Windows®
software and the USB connection
cable form a practical tool for
transferring logged data and real
time measurement data from the
MI70 to a PC.
What’s more, with its fast response
time, the additional temperature
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210785EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
133
www.vaisala.com
Vaisala Barometric Pressure Transfer
Standard PTB330TS
Technical data
Available Parameters
Technical data
Pressure parameters
Humidity and temperature
parameters
These specifications apply when MI70, PTB330 and
HMP155 are used together in the PTB330TS product.
For individual specifications, please refer to the product
documentation and brochures of the PTB330 and HMP155.
Inputs and outputs
MI70 probe ports
MI70 data interface
General
Operating temperature range
Operating humidity range
Maximum pressure limit
Power supply
PTB330TS is in conformity with the following EU directives:
- EMC Directive (2004/108/EC) Complies with the EMC product family standard EN61326-1,
Electrical equipment for measurement control and laboratory use - Basic immunity test
requirements.
- Low Voltage Directive (2006/95/EC)
- ROHS Directive (2002/95/EC)
Performance
Barometric pressure (PTB330)
Measurement range
Linearity*
Hysteresis*
Repeatability*
Calibration uncertainty**
Accuracy at +20 °C (+68 °F) ***
Temperature dependence****
Total accuracy -40... +60 °C (-40...+140 °F)
Long-term stability
Settling time at power-up (one sensor)
Response time (one sensor)
Acceleration sensitivity
500 ... 1100 hPa
±0.05 hPa
±0.03 hPa
±0.03 hPa
±0.07 hPa
±0.10 hPa
±0.1 hPa
±0.15 hPa
±0.1 hPa/year
4s
2s
negligible
Defined as ±2 standard deviation limits of endpoint nonlinearity, hysteresis or
repeatability error.
㻖㻖㻌 㻰㼑㼒㼕㼚㼑㼐㻌㼍㼟㻌㼼㻞㻌㼟㼠㼍㼚㼐㼍㼞㼐㻌㼐㼑㼢㼕㼍㼠㼕㼛㼚㻌㼘㼕㼙㼕㼠㼟㻌㼛㼒㻌㼕㼚㼍㼏㼏㼡㼞㼍㼏㼥㻌㼛㼒㻌㼠㼔㼑㻌㼣㼛㼞㼗㼕㼚㼓㻌㼟㼠㼍㼚㼐㼍㼞㼐㻌㼕㼚㼏㼘㼡㼐㼕㼚㼓㻌
㼠㼞㼍㼏㼑㼍㼎㼕㼘㼕㼠㼥㻌㼠㼛㻌㻺㻵㻿㼀㻚
㻖㻖㻖㻌 㻰㼑㼒㼕㼚㼑㼐㻌㼍㼟㻌㼠㼔㼑㻌㼞㼛㼛㼠㻌㼟㼡㼙㻌㼛㼒㻌㼠㼔㼑㻌㼟㼝㼡㼍㼞㼑㼟㻌㻔㻾㻿㻿㻕㻌㼛㼒㻌㼑㼚㼐㼜㼛㼕㼚㼠㻌㼚㼛㼚㻙㼘㼕㼚㼑㼍㼞㼕㼠㼥㻘㻌㻌㼔㼥㼟㼠㼑㼞㼑㼟㼕㼟㻌㼑㼞㼞㼛㼞㻘㻌
㼞㼑㼜㼑㼍㼠㼍㼎㼕㼘㼕㼠㼥㻌㼑㼞㼞㼛㼞㻌㼍㼚㼐㻌㼏㼍㼘㼕㼎㼞㼍㼠㼕㼛㼚㻌㼡㼚㼏㼑㼞㼠㼍㼕㼚㼠㼥㻌㼍㼠㻌㼞㼛㼛㼙㻌㼠㼑㼙㼜㼑㼞㼍㼠㼡㼞㼑㻚
㻖㻖㻖㻖㻌㻰㼑㼒㼕㼚㼑㼐㻌㼍㼟㻌㼼㻞㻌㼟㼠㼍㼚㼐㼍㼞㼐㻌㼐㼑㼢㼕㼍㼠㼕㼛㼚㻌㼘㼕㼙㼕㼠㼟㻌㼛㼒㻌㼠㼑㼙㼜㼑㼞㼍㼠㼡㼞㼑㻌㼐㼑㼜㼑㼚㼐㼑㼚㼏㼑㻌㼛㼢㼑㼞㻌㼠㼔㼑㻌㼛㼜㼑㼞㼍㼠㼕㼚㼓㻌
㼠㼑㼙㼜㼑㼞㼍㼠㼡㼞㼑㻌㼞㼍㼚㼓㼑㻚
134
2
RS-232 (accessible only with MI70
Link software)
10 ... 35 VDC (if not powered by
MI70)
RS-232C
RJ45 (service port)
Male 8-pin M12 (user port)
RS-485
Male 8-pin M12
PTB330 supply voltage
-10 ... +40 °C (+14 ... +104 )°F
non-condensing
5000 hPa abs.
Rechargeable NiMH battery pack
with AC-adapter or 4xAA-size
alkalines, type IEC LR6
Operation time
(using rechargeable battery pack)
Continuous use with PTB330 11 h typical at +20 °C (+68 °F)
Datalogging use
up to 30 days
Menu languages
English, Chinese, French, Spanish,
German, Russian, Japanese,
Swedish, Finnish
Display
LCD with backlight, graphic
trend display of any parameter,
character height up to 16 mm
Data logging capacity
2700 points
Alarm
audible alarm function
*
Accessories
P, P3h, HCP, QFE, QNH
RH, T, Tdf, Td, x, Tw
PTB330 data interface
PTB330 serial I/O connectors
HMP155 data interface
HMP155 serial I/O connector
Mechanics
Housing material
Housing classification
Pressure connector
Pressure fitting
Measurement range
Accuracy (incl. non-linearity, hysteresis and
repeatability) at +15 ... +25 °C (+59 ... +77 °F)
* Defined as ±2 standard deviation limits. Small variations possible, see also calibration
certificate.
Temperature (HMP155)
Measurement range
Accuracy
-10 ... +20 °C
G-AlSi 10 Mg (DIN 1725)
IP65
M5 (10-32) internal thread
barbed fitting for 1/8” I.D.
tubing or quick connector with
shutoff valve for 1/8” hose
0 ... 100 %RH
±1 %RH (0 ... 90 %RH)
±1.7 %RH (90 ... 100 %RH)
-10 ... +40 °C (-4 ... 104 °F)
±(1.0 + 0.008 x reading) %RH
Factory calibration uncertainty (+20 °C /+68 °F)
±0.6 %RH (0 ... 40 %RH)*
±1.0 %RH (40 ... 97 %RH)*
Humidity sensor
HUMICAP180R
HUMICAP180RC
Response time at +20 °C in still air with a sintered PTFE filter
63 %
20 s
90 %
60 s
-10 ... +40 °C (+14 ... +104 °F)
±(0.176 - 0.0028 x
temperature) °C
+20 ... +40 °C
±(0.07 + 0.0025 x
temperature) °C
Accuracy over temperature range (see graph overleaf)
Temperature sensor Pt100 RTD 1/3 Class B IEC 751
Response time with additional temperature probe in 3 m/s air flow
63 %
<20 s
90 %
<35 s
MI70 – PTB330 Spiral Cable
USB-RJ45 serial connection cable
Serial connection cable
Barbed fitting 1/8”
Quick Connector 1/8”
Transport case with interior foams
and tabletop casing for PTB330
Tabletop casing for PTB330
223235SP
219685
19446ZZ
19498SP
220186
224068SP
224064SP
MI70
USB cable for MI70,
includes MI70 Link software
MI70 Link software
MI70 connection cable to HMT330,
MMT330, DMT340, HMT100, PTB330
MI70 battery pack
variety of AC adapters available
219687
MI70LINK
211339
26755
HMP155
PTB330
Relative humidity (HMP155)
PTB330
HMP155
Housing material
Housing classification
Additional T-probe cable length
Cable material
Sensor protection
PC
IP66
2m
PUR
Sintered PTFE
MI70 MEASUREMENT INDICATOR
Housing classification
Housing material
IP54
ABS/PC blend
HMP155 – MI70 connection cable
Protection set for HMP155 calibration
buttons: protective cover,
2 O-rings and protective plug
USB cable for HMP155
Sintered teflon filter + O-ring
Humidity sensor
Humidity Calibrator
221801
221318
221040
219452SP
HUMICAP180R
HMK15
TRANSPORT CASE
Housing classification
(when closed)
Plastic parts
Metal parts
Interior foam material
Weight with all instruments and
typical accessories
Exterior dimensions (LxWxH)
IP67
TTX01®, PP+SEBS, POM
stainless steel AISI303
PE and polyether
5.9 kg
405×330×165 mm
(15.94×12.99×6.50) inch
For more information, visit
www.vaisala.com or contact
us at [email protected]
Accuracy of HMP155 temperature measurement over
temperature range
Ref. B210786EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
135
www.vaisala.com
PTB210 Digital Barometer
Technical data
Operating range (1hPa=1mbar)
General
Pressure range (order specified)
serial output
t'BDUPSZTFUUJOH
analog output
Operating temperature range
Humidity range
500 ... 1100 hPa
50 ... 1100 hPa
500 ... 1100 hPa
600 ... 1060 hPa
800 ... 1060 hPa
900 ... 1100 hPa
-40 ... +60 °C (-40 ... +140 °F)
non-condensing
SERIAL OUTPUT
Current consumption
normal mode
power down mode
shutdown mode
Shutdown
Settling time at power up
4FSJBM*0GBDUPSZTFUUJOHt
Accuracy
SERIAL OUTPUT (units in hPa)
Pressure range
The PTB210 paired with the SPH10
Static Pressure Head.
The Vaisala BAROCAP® Digital Barometer PTB210 is a reliable outdoor barometer
that withstands harsh conditions.
Non linearity*
Hysteresis*
Repeatability*
Calibration uncertainty**
Accuracy at +20 °C (+68 °F)***
Temperature dependence****
Total accuracy***
-40 ... +60 °C (-40 ... +140 °F)
Long term stability (hPa/year)
500 ... 1100
Class A
Class B
± 0.10
± 0.15
± 0.05
± 0.05
± 0.05
± 0.05
± 0.07
± 0.15
± 0.15
± 0.20
± 0.20
± 0.20
± 0.25
± 0.30
± 0.10
± 0.10
50 ... 1100
± 0.20
± 0.10
± 0.10
± 0.20
± 0.35
± 0.40
± 0.50
± 0.20
ANALOG OUTPUT
For harsh environments
®
The Vaisala BAROCAP Digital
Barometer PTB210 is ideal for
outdoor installations and harsh
environments. The barometers
are designed to operate in a
wide temperature range, and the
electronics housing provides IP65
(NEMA 4) standardized protection
against sprayed water.
Features/Benefits
▪
500 ... 1100 hPa or
50 ... 1100 hPa pressure ranges
with serial output
▪
Different scalings between
500 ... 1100 hPa with analog
output
▪
Electronics housing IP65
protected against sprayed
water
▪
Accurate and stable
measurement
▪
NIST traceable
(certificate included)
136
The PTB210 barometers are ideal
for use in applications such as
weather stations, data buoys and
ships, airports, and agrology. They
are also an excellent solution for
monitoring barometric pressure in
industrial equipment such as laser
interferometers and engine test
benches.
Several pressure ranges
The PTB210 barometers are designed
for various pressure ranges. They are
available in two basic configurations:
serial output for 500 ... 1100 hPa and
50 ... 1100 hPa and analog output
with different scalings between
500 ... 1100 hPa.
Accurate and stable
measurement
All the PTB210 barometers are
digitally adjusted and calibrated by
using electronic working standards.
A higher accuracy barometer, that is
fine-tuned and calibrated against a
High Precision Pressure Calibrator,
is available for the 500 ... 1100 hPa
pressure range.
In addition, the PTB210 integrates
directly with Vaisala Static Pressure
Head Series SPH10/20. This pairing
offers accurate measurement in all
wind conditions.
Vaisala BAROCAP®
technology
The PTB210 barometers use the
Vaisala BAROCAP® Sensor, a silicon
capacitive absolute pressure sensor
developed by Vaisala for barometric
pressure applications. The Vaisala
BAROCAP® Sensor provides
excellent hysteresis and repeatability
characteristics and outstanding
temperature and long-term stability.
All PTB210 barometers are delivered
with a factory calibration certificate
which is NIST traceable.
Non linearity*
Hysteresis*
Repeatability*
Calibration uncertainty**
Accuracy at +20 °C (+68 °F)***
Temperature dependence****
Total accuracy*** -40 ... +60 °C (-40 ... +140 °F)
Long term stability
± 0.20 hPa
± 0.05 hPa
± 0.05 hPa
± 0.15 hPa
± 0.30 hPa
± 0.50 hPa
± 0.60 hPa
± 0.10 hPa/year
*
Defined as the ±2 standard deviation limits of end point
non-linearity, hysteresis error or repeatability error.
** Defined as ±2 standard deviation limits of inaccuracy of
the working standard including traceability to NIST.
*** Defined as the root sum of the squares (RSS) of end
point non-linearity, hysteresis error, repeatability error and
calibration uncertainty at room temperature.
**** Defined as ±2 standard deviation limits of temperature
dependence over the operating temperature range.
For more information, visit
www.vaisala.com or contact
us at [email protected]
parity
data bits
stop bits
Baud rate
Response time
Resolution
N"t
< 0.8 mA
0.2 mA
ON/OFF
2s
RS232C
RS232C /TTL (optional)
RS485, non isolated (optional)
OPOFFWFOtPEE
t
t
t
Tt
0.01 hPa (1 measurement/s)
0.03 hPa (10 measurements/s)
ANALOG OUTPUT
Outputs
Current consumption
normal mode
shutdown mode
Shutdown
Response time
Resolution
Measurement rate
0 ... 5 VDC, 0 ... 2.5 VDC (order specified)
< 8 mA
0.2 mA
ON/OFF
500 ms
300 μV
3 measurements/s
ALL MODELS
Supply voltage (reverse polarity protected)
with RS232/TTL output
5 ... 28 VDC
with RS485 or analog output
8 ... 18 VDC
Max. pressure
5 000 hPa abs.
Pressure connector
M5 (10-32) internal thread
Pressure fitting
barbed fitting for 1/8" I.D. tubing
Housing
electronics
IP65 (NEMA 4)
sensor
IP53
Housing material
PC plastic
Supply/output cable length
1, 2, 3, 5 or 10 m
Instrument
110 g
Cable
28 g/m
Electromagnetic compatibility
Complies with EMC standard
EN61326-1, Generic Environment
Ref. B210942EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
137
www.vaisala.com
Technical data
PTB110 Barometer for Industrial Use
Operating range (1 hPa=1mbar)
Accuracy
Pressure ranges
Linearity*
±0.25 hPa
Hysteresis*
±0.03 hPa
Repeatability*
±0.03 hPa
Calibration uncertainty**
±0.15 hPa
Accuracy at +20 °C***
±0.3 hPa
* Defined as ±2 standard deviation limits of end-point
non-linearity, hysteresis error or repeatability error.
** Defined as ±2 standard deviation limits of inaccuracy of the
working standard including traceability to NIST.
*** Defined as the root sum of the squares (RSS) of end-point
non-linearity, hysteresis error, repeatability error and
calibration uncertainty at room temperature.
Features/Benefits
PTB110
Accuracy and stability
▪
▪
▪
▪
▪
Vaisala BAROCAP® sensor
The Vaisala BAROCAP® Barometer
PTB110 is designed both for accurate
barometric pressure measurements
at a room temperature and for
general environmental pressure
monitoring over a wide temperature
range.
The excellent long-term stability of
the barometer minimizes or even
removes the need for field adjustment
in many applications.
▪
Output voltage 0 ... 2.5 or
0 ... 5 VDC
▪
Current consumption less than
4 mA
▪
Mountable on a (35 mm wide)
DIN rail
▪
NIST traceable (certificate
included)
138
Several pressure ranges
Accuracy ±0.3 hPa at +20 °C
Long-term stability
On/off control with external
trigger
Vaisala BAROCAP®
technology
The PTB110 barometer uses the
Vaisala BAROCAP® Sensor, a silicon
capacitive absolute pressure sensor
developed by Vaisala for barometric
pressure measurement applications.
The sensor combines the outstanding
elasticity characteristics and
mechanical stability of single-crystal
silicon with the proven capacitive
detection principle.
Applications
The PTB110 is suitable for a variety of
applications, such as environmental
pressure monitoring, data buoys,
laser interferometers, and in
agriculture and hydrology.
The compact PTB110 is especially
ideal for data logger applications as it
has low power consumption. Also an
external On/Off control is available.
This is practical when the supply of
electricity is limited.
For more information, visit
www.vaisala.com or contact
us at [email protected]
TOTAL ACCURACY AT
+15 ... +25 °C (+59 ... +77 °F)
0 ... +40 °C (+32 ... +104 °F)
-20 ... +45 °C (-4 ... +113 °F)
-40 ... +60 °C (-40 ... +140 °F)
Long-term stability
±0.3 hPa
±0.6 hPa
±1.0 hPa
±1.5 hPa
±0.1 hPa/year
Dimensions
Dimensions in mm (inches)
2.69
68.40
0.14
3.50
1.11
28.1
0.62
15.82
3.54
90
The Vaisala BAROCAP® Barometer PTB110 offers outstanding long-term stability.
10 ... 30 VDC
with TTL level trigger
negligible
less than 4 mA
less than 1 μA
0 ... 2.5 VDC
0 ... 5 VDC
Output frequency
500 ... 1100 Hz
Resolution
0.1 hPa
Load resistance
minimum 10 kohm
Load capacitance
maximum 47 nF
Settling time
1 s to reach full accuracy after power-up
Response time
500 ms to reach full accuracy
after a pressure step
Acceleration sensitivity
negligible
Pressure connector
M5 (10-32) internal thread
Pressure fitting
barbed fitting for 1/8"
Minimum pressure limit
0 hPa abs
Maximum pressure limit
2000 hPa abs
Electrical connector
removable connector for
5 wires (AWG 28 ... 16)
Terminals
Pin 1: external triggering
Pin 2: signal ground
Pin 3: supply ground
Pin 4: supply voltage
Pin 5: signal output
Housing material, plastic cover
ABS/PC blend
Housing classification
IP32
Metal mounting plate
Al
Weight
90 g
Electromagnetic compatibility
Complies with EMC standard
EN 61326-1, Electrical equipment for
measurement, control and laboratory use - EMC
requirements - for use in industrial locations
0.16
4
Supply voltage
Suppply voltage control
Supply voltage sensitivity
Current consumption
in shutdown mode
Output voltage
3.00
76.20
General
3.83
97.3
Temperature range
Humidity range
500 ... 1100 hPa
600 ... 1100 hPa
800 ... 1100 hPa
800 ... 1060 hPa
600 ... 1060 hPa
-40 ... +60 °C (-40 ... +140 °F)
non-condensing
0.53
13.40
0.28
Ø 7.20
BAROCAP® is a registered trademark of Vaisala.
Ref. B210681EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
139
www.vaisala.com
SPH10/20 Static Pressure Heads
for Minimizing Wind Induced Error
Wind induced effects are one of
the main sources of error when
measuring barometric pressure.
Variations due to strong and gusty
wind can be overcome by using a
static pressure head to ‘filter out’ the
effect of dynamic pressure.
The Vaisala Static Pressure Head
Series SPH10/20 are designed to
minimize the errors caused by wind.
The wind tunnel tested structure
is both horizontally and vertically
symmetrical. This design ensures
reliable barometric pressure
measurements in all weather.
Ideal for outdoor
installations
Vaisala’s static pressure heads
are available in two models: the
Vaisala Static Pressure Head SPH10
is a basic version, and the Vaisala
Static Pressure Head SPH20 is a
heated version for reliable operation
in snowy and icy conditions. The
warmed SPH20 contains a thermostat
that switches on the warming power
at temperatures, where the risk of
icing may occur.
Technical data
General
Operating temperature
Weight
SPH10
SPH20
Material
Mounting
Hose connection
SPH10/20 static pressure heads are
durable and weather resistant.
The SPH10/20 protects against
rain and condensed water, thus
preventing capillary condensation
of a water column in the pressure
channel which results in pressure
error. The drain holes in the lower
plate allow rain and water to flow
out. The static pressure heads have
internal netting which prevents
insects and debris from blocking the
pressure channel.
SPH20
-60 ... +80 °C (-76 ... +176 °F)
800 g
1360 g
PC plastic, offshore aluminium
with 2 bolts (M6 X 20 mm min)
barbed fitting for 4 mm I.D. hose
or Rp1/4 thread (parallel)
Electrical connections
Power supply
M12 connector
factory setting 12 V
changed connection 24 V
Thermostat switching temperature
On
Off
Power consumption during heating
+4 °C (±3 °C)
+39.2 °F (±4.4 °F)
+13 °C (±3 °C)
+55.4 °F (±4.4 °F)
70 W
Dimensions
Dimensions in mm
SPH10
Carefree maintenance
The SPH10/20 static pressure heads
are easy to install and disassemble,
service and clean – even at the
installation site. Vaisala BAROCAP®
Digital Barometer PTB210 can be
installed directly on top of the
SPH10/20 static pressure heads.
Other barometers can be connected
to the heads with pressure tubing.
SPH10 and SPH20 are a perfect pair
for all Vaisala barometers. They
ensure an accurate and reliable
measurement in all weather
conditions.
The SPH10/20 is easy to install and
connect. In the picture, a SPH10 is
connected to a PTB210 barometer.
SPH20
Composed of ultraviolet stabilized PC
plastics and offshore aluminium, the
Features/Benefits
▪
▪
Minimizes wind induced error
▪
Wind tunnel tested structure
Reliable barometric pressure
measurement in all weather
▪
▪
Easy-to-clean
Easy-to-install
For more information, visit
www.vaisala.com or contact
us at [email protected]
140
Ref. B210907EN-A ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
141
Wind
www.vaisala.com
Vaisala Weather Transmitter WXT520
Access to Real Time Weather Data
Technical data
Wind
Air temperature
SPEED
range
response time
accuracy
0 ... 35 m/s
35 m/s ... 60 m/s
output resolutions and
units
0 ... 60 m/s
250 ms
±0.3 m/s or ±3%,
whichever is greater
±5%
0.1 m/s, 0.1km/h,
0.1 mph, 0.1 knots
0 ... 360°
250 ms
±3°
1°
Liquid precipitation
RAINFALL DURATION
The WXT520 has an automatic control circuit that switches the heating on
at low temperatures.
output resolution and
unit
Features/Benefits
WXT520
▪
Measures 6 most
essentialweather parameters
▪
▪
Accurate and stable
The Vaisala Weather Transmitter
WXT520 measures barometric
pressure, humidity, precipitation,
temperature, and wind speed and
direction.
▪
Compact, light-weight
▪
Easy to install with one-bolt
mounting method
▪
▪
▪
No moving parts
▪
▪
▪
USB connection
142
Low power consumption
– works also with solar panels
Heating available
Vaisala Configuration Tool
for pc
IP66 housing with mounting kit
Applications: weather stations,
dense networks, harbors,
marinas
To measure wind speed and
direction, the WXT520 has the
Vaisala WINDCAP®sensor that uses
ultrasound to determine horizontal
wind speed and direction.
The array of three equally spaced
transducers on a horizontal plane is
a Vaisala specific design. Barometric
pressure, temperature, and humidity
measurements are combined in
the PTU module using capacitive
measurement for each parameter.
It is easy to change the module
without any contact with the
sensors.
The WXT520 is immune to flooding
clogging, wetting, and evaporation
losses in the rain measurement.
Measuring acoustic
precipitation
The WXT520 precipitation
measurement is based on the unique
Vaisala RAINCAP® Sensor, which
detects the impact of individual
rain drops. The signals exerting
from the impacts are proportional
to the volume of the drops.
Hence, the signal from each drop
can be converted directly to the
accumulated rainfall.
The WXT520 measures accumulated
rainfall, rain intensity and duration of
the rain — all in real time.
The Vaisala RAINCAP® Sensor is the
only maintenance-free precipitation
sensor on the market.
RAIN INTENSITY
range
output resolutions and
units
HAIL
ƒ&
azimuth
response time
accuracy
output resolution and unit
output resolutions and
units
accuracy
Δ ƒ&
DIRECTION
RAINFALL
Range
-52 ... +60 °C (-60 ... +140 °F)
Accuracy for sensor at +20 °C
±0.3 °C (±0.5 °F)
Accuracy over temperature range (see graph below)
cumulative accumulation after the
latest automatic or manual reset
0.01 mm, 0.001 inches
5%*
counting each ten-second increment
whenever water droplet is detected
Output resolutions and units
0.1 °C, 0.1 °F
Barometric pressure
Range
Accuracy
600 ... 1100 hPa
±0.5 hPa at 0 ... +30 °C (+32 ... +86 °F)
±1 hPa at -52 ... +60 °C (-60 ... +140 °F)
0.1 hPa, 10 Pa, 0.0001 bar,
0.1 mmHg, 0.01 inHg
Output resolutions and
units
Relative humidity
10 s
one-minute running average
in ten-second steps
0 ... 200 mm/h (broader range with
reduced accuracy)
0.1 mm/h, 0.01 inches/h
cumulative amount of hits against
the collecting surface
output resolutions and
units
0.1 hits/cm2, 0.01 hits/in2, 1 hits
counting each ten-second increment
whenever hailstone is detected
output resolution and unit
10 s
HAIL INTENSITY
one-minute running average
in ten-second steps
output resolutions and
0.1 hits/cm2h, 1 hits/in2h,
units
1 hits/h
* Due to the nature of the phenomenon, deviations caused by
spatial variations may exist in precipitation readings, especially
in a short time scale. The accuracy specification does not include
possible wind induced errors.
HAIL DURATION
For more information, visit
www.vaisala.com or contact
us at [email protected]
Range
Accuracy
Output resolution and unit
0 ... 100 %RH
±3 %RH within 0 ... 90 %RH
±5 %RH within 90 ... 100 %RH
0.1 %RH
General
Operating temperature
Storage temperature
Operating voltage
Typical power consumption
Heating voltage
Serial data interface
Weigth
Housing
Housing with mounting kit
-52 ... +60 °C (-60 ... +140 °F)
-60 ... +70 °C (-76 ... +158 °F)
5 ... 32 VDC
3 mA at 12 VDC (with defaults)
5 ... 32 VDC / 5 ... 30 VACRMS)
SDI-12, RS-232, RS-485, RS-422,
USB connection,
650 g (1.43 lb)
IP65
IP66
Electromagnetic compatibility
Complies with EMC standard
EN61326-1; Industrial
Environment IEC standards
IEC 60945/61000-4-2 ... 61000-4-6
Ref. B210417EN-F ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
143
Wind
Power supply
WIND SPEED
The WMT52 is ideal for use in marine
applications as the housing with
the mounting kit is water resistant.
The WMT52 is also suitable for
wind energy and environmental
monitoring, for example, for
measuring the distribution of air
pollution and road tunnel ventilation.
Easy to install
The WMT52 is delivered fully
assembled and configured from
the factory. With the Vaisala
Configuration Software Tool you
can change the settings, such as
averaging times, output mode, update
intervals, measured variables and
message contents.
The Vaisala WINDCAP® Ultrasonic Wind Sensor WMT52 - stable and inexpensive
wind measurement for demanding applications.
Features/Benefits
▪
Measures horizontal wind
speed and wind direction
▪
Triangular design ensures
excellent data availability
▪
▪
▪
▪
▪
▪
▪
No moving parts
144
Maintenance-free
Optional heating available
Compact, durable and robust
Low power consumption
IP66 housing with mounting kit
Applications: marine, wind
energy, environmental
monitoring
Proven Vaisala
performance
The Vaisala WINDCAP® Ultrasonic
Wind Sensor WMT52 incorporates
decades of Vaisala experience in
wind measurement using ultrasound
to determine horizontal wind speed
and direction.
With no moving parts, the WMT52
has high sensitivity as the
measurement time constant and
starting threshold are virtually
zero. This makes it superior to the
conventional mechanical wind
sensors.
The WMT52 is designed to operate
without periodic field calibration and
maintenance.
The WMT52 can be mounted either
on top of a pole mast or on a cross
arm.
When using the optional mounting
kit, the north alignment needs to be
performed only once.
Heating
The optional heating available in the
WMT52 assists measurements in
the freezing weather conditions and
during snowfall.
As the heating circuit is independent
of the operational power, separate
supplies can be used. Heating is
switched on automatically at low
temperatures, well before the
freezing point.
Range
Response time
Available variables
Accuracy
0 ... 35 m/s
35 m/s ... 60 m/s
Output resolution
0 ... 60 m/s
250 ms
average, maximum, and minimum
±0.3 m/s or ±3 % whichever is greater
±5 %
0.1 m/s (km/h, mph, knots)
WIND DIRECTION
0 ... 360°
250 ms
average, maximum, and minimum
±3°
1°
MEASUREMENT FRAME
Update interval
1 ... 3600 s (=60 min), at one second steps
on the basis of samples taken
at 4 Hz rate (configurable)
1 ... 3600 s (=60 min), at one-second steps
0.1 mA at 12 VDC
14 mA at 5 VDC
3 mA at 12 VDC
(default measuring intervals)
5 ... 32 VDC / 5 ... 30 VACRMS)
Mounting kit
Bird spike kit
Surge protector for sensor
Self-diagnostics
Start-up
Serial data interface
Communication protocols
Baud rate
Operating temperature
Storage temperature
Dimensions
height
diameter
weight
Housing
Housing with mounting kit
Vibration
212792
212793
WSP150
Electromagnetic compatibility
Complies with EMC standard: EN61326-1, Industrial Environment
IEC standards
IEC 60945/61000-4-2 ... 61000-4-6
Dimensions
Dimensions in mm (inches)
Ø 115 (4.53)
General
separate supervision message,
unit/status fields to validate
measurement quality
automatic, <10 s from power on to
the first valid output
SDI-12, RS-232, RS-485, RS-422,
USB connection
SDI-12 v1.3, ASCII automatic &
polled, NMEA 0183 v. 3.0
with query option
1200 ... 115 200
-52 ... +60 °C (-60 ... +140 °F)
-60 ... +70 °C (-76 ... +158 °F)
139 mm (5.7")
114 mm (4.49")
510 g (1.12 lb)
IP65
IP66
IEC 60945 paragraph 8
Ø 114 (4.49)
mounting kit
WINDCAP® is a registered trademark of Vaisala.
Low power consumption
The WMT52 has very low power
consumption; during the idle mode
the device typically consumes about
2 ... 3 mW.
Heating voltage
5 ... 32 VDC
Accessories
Azimuth
Response time
Available variables
Accuracy
Output resolution
Averaging time
Operating voltage
Power consumption on average
minimum
maximum
typical
99 (3.9)
Applications
139 (5.48)
WMT52 Ultrasonic Wind Sensor for
Accurate and Stable Measurement
Technical data
32 (1.3)
www.vaisala.com
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210553EN-D ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
145
www.vaisala.com
WA15 Wind Set for High Performance
Wind Measurement
per revolution. This generates a pulse output from the
phototransistor.
The output pulse rate is directly proportional to wind
speed (e.g. 246 Hz = 24.6 m/s). However, for the highest
accuracy, the characteristic transfer function should be
used to compensate for starting inertia.
(See technical data.)
Sensitive wind vane
The WAV151 is a counter-balanced, low-threshold,
optoelectronic wind vane. Infrared LEDs and
phototransistors are mounted on six orbits on each
side of a 6-bit GRAY-coded disc. Turned by the vane,
the disc creates changes in the code received by the
phototransistors. The output code resolution is ±2.8°.
The WA15 is based on accurate sensors installed on a large
crossarm. It is designed for demanding wind measurement
applications.
With a proven track record of successful installations, the
Vaisala Wind Set WA15 has earned its reputation as the
industry standard in the wind sensor market.
The WA15 consists of a Vaisala Anemometer WAA151, a
Vaisala Wind Vane WAV151, an optional crossarm, a power
supply and cabling.
Anemometer with excellent linearity
The WAA151 is a fast response, low-threshold anemometer.
Three lightweight, conical cups mounted on the cup wheel,
provide excellent linearity over the entire operating range,
up to 75 m/s.
A wind-rotated chopper disc attached to the shaft of
the cup wheel cuts an infrared light beam 14 times
Heated bearings withstand cold weather
Heating elements in the shaft tunnels of both the
anemometer and vane keep the bearings above freezing in
cold climates.
Complete package available
The anemometer and vane are designed to be mounted on
Vaisala crossarms.
The WHP151 power supply provides the operating and
heating power needed for the WA15. The power supply,
as well as the signal and power cables are available as
options.
Technical data
Technical data
Vaisala Anemometer WAA151
Vaisala Wind Vane WAV151
Wind speed
Wind direction
Measurement range
0.4 ... 75 m/s
Starting threshold
< 0.5 m/s *
Distance constant
2.0 m
Characteristic transfer function
U = 0.328 + 0.101 × R
(where U = wind speed [m/s], R = output pulse rate [Hz])
Accuracy (within range 0.4 ... 60 m/s)
with characteristic transfer function
± 0.17 m/s **
with transfer function U = 0.1 × R
± 0.5 m/s***
Measurement range at wind speed 0.4 ... 75 m/s
Starting threshold
Resolution
Damping ratio
Overshoot ratio
Delay distance
Accuracy
General
General
Operating power supply
Uin = 9.5 ... 15.5 VDC, 20 mA typical
Heating power supply
AC or DC 20 V, 500 mA nominal
Output
0 ... 750 Hz square wave
Transducer output level
high state > Uin-1.5 V
with Iout < +5 mA
low state < 2.0 V
with Iout > –5 mA
Settling time after power turn-on
< 30 μs
Plug 6-PIN
MIL-C-26482 type
Cabling
6-wire cable through crossarm
Recommended connector at cable end SOURIAU MS3116F10-6P
Operating temperature with heating
-50 ... +55 °C (-58 ... +131 °F)
Storage temperature
-60 ... +70 °C (-76 ... +158 °F)
Material
housing
AlMgSi, grey anodized
cups
PA, reinforced with carbon fibre
Dimensions
240 (h) × 90 (Ø) mm
Swept radius of cup wheel
91 mm
Weight
570 g
Operating power supply
Uin = 9.5 ... 15.5 VDC, 20 mA typical
Heating power supply
AC or DC 20 V, 500 mA nominal
Output code
6-bit parallel GRAY
Output levels
high state > Uin –1.5 V
With Iout < +5 mA
low state < 1.5 V
With Iout > –5 mA
Settling time after power turn-on
< 100 μs
Plug 10-PIN
MIL-C-26482 type
Cabling
10-wire cable through crossarm
Recommended connector at cable end SOURIAU MS3116F12-10P
Operating temperature with heating
-50 ... +55 °C (-58 ... +131 °F)
Storage temperature
-60 ... +70 °C (-76 ... +158 °F)
Material
housing
AlMgSi, grey anodized
wave
Alsi 12 anodized
Dimensions
300 (h) × 90 (Ø) mm
Swept radius of vane
172 mm
Weight
660 g
Test compliance
Test compliance
Wind tunnel tests
Exploratory vibration test
Humidity test
Salt fog test
ASTM standard method D5096-90
MIL-STD-167-1
MIL-STD-810E, Method 507.3
MIL-STD-810E, Method 509.3
Complies with EMC standard EN61326-1:1997 + Am1:1998 +
Am2:2001; Generic Environment
Vaisala Wind Set WA15
Features/Benefits
Options and accessories
▪
▪
High-performance wind measurement set
▪
▪
▪
Accurate wind speed and direction measurement
▪
Heated shaft prevents bearings from freezing
Crossarm and termination box
16-lead signal cable
6-lead power cable
Crossarm and analog transmitter
6-lead cable for signal and power
Crossarm and serial RS485 transmitter
Serial RS485 transmitter card
Power supply
Set of bearings and gasket
Cup assembly
Tail assembly
Long and successful track record in meteorological
applications
Low measurement starting threshold
Conical anemometer cups provide excellent
linearity
146
0 ... 360°
<0.4 m/s
±2.8°
0.19
0.55
0.4 m
better than ±3°
Wind tunnel tests
ASTM standard method D5366-93
(for starting threshold, distance constant, transfer function)
Exploratory vibration test
MIL-STD-167-1
Humidity test
MIL-STD-810E, Method 507.3
Salt fog test
MIL-STD-810E, Method 509.3
Complies with EMC standard EN61326-1:1997 + Am1:1998;
Am2:2001; Generic Environment
*
WAC151
ZZ45048
ZZ45049
WAT12
ZZ45049
WAC155
WAC155CB
WHP151
16644WA
7150WA
6389WA
Measured with cup wheel in position least favoured by flow
direction. Optimum position gives approx. 0.35 m/s threshold.
** Standard Deviation
*** Typical error vs. speed with the "simple transfer function" used.
RANGE (m/s)
ERROR (m/s)
0-3
-0.4
3-10
-0.3
10-17
-0.2
17-24
-0.1
24-31
0.0
31-37
+0.1
37-44
+0.2
44-51
+0.3
51-58
+0.4
For more information, visit
www.vaisala.com or contact
us at [email protected]
58-65
+0.5
Ref. B210382EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
147
Vaisala Service Offering
10 D Gill Street, Woburn, MA 01801
USA and Canada Tel: 1-888-VAISALA (824-7252)
Brazil: 0800-891-7392
International Calls: + 781-933-4500
Fax: + 1-781-933-8029
Email: [email protected]
www.vaisala.com/SERVICE
Vaisala Service Offering
Vaisala offers you calibration and
maintenance services. You can choose
from different options to customize
your service agreement to cover all
your Vaisala instruments.
Easy and efficient
calibration
Calibration is an essential part
of measurement instrument
maintenance. We offer Service
agreements designed to fulfill your
calibration and maintenance needs.
Your instruments can be enrolled in
the Calibration Reminder Program,
which provides advance notification
when regular calibration is due. For
most Vaisala instruments, it also
includes a calibration certificate with
the 'before' and 'after' adjustment data.
You can choose a standard (factory)
calibration or accredited calibration
for a certain period of time. The
standard (factory) calibration is
traceable and ISO 9001 compliant.
The standard accreditation e.g. for
Vaisala HUMICAP® Humidity and
Temperature Transmitter Series
HMT330 includes seven humidity
and one temperature point at room
temperature. Vaisala also offers
accredited calibrations for many of its
products.
Vaisala Service Centers are accredited
and their working procedures
are approved by third party
organizations. This is confirmed
by the name and logo of the local
accrediting body appearing on
the report documentation. The
documentation includes uncertainty
calculations. Accredited calibrations
are recommended especially for
the measurement instruments that
are used as transfer standards
or in demanding measurement
applications.
All accredited calibrations comply
with ISO 17025 and are traceable to
international standards.
Service and Calibration Standards Laboratory –
Lifetime Accuracy from the Vaisala Service Center
Add benefits with options
Features/Benefits
The Vaisala Service Agreements
are available with multiple
optional services. You can select
the options based on your needs.
r
r
r
r
▪
SCHEDULED PART DELIVERY:
With this option Vaisala will
keep an exchange unit (or
units) in stock which will be
shipped to you before the
recommended calibration or
maintenance time.
▪
PRIORITY TECHNICAL
SUPPORT:
Priority technical support
increases uptime of your
operations. Our response time
to your technical inquiries can
be agreed according to your
need.
You can also customize your
calibration agreement, when needed.
Lifetime accuracy with
Vaisala service agreement
Regular maintenance is a key factor in
ensuring measurement accuracy.
▪
A Vaisala Service Agreement is
a convenient way to gain access
to professional support over the
life cycle of your instruments.
Agreements can be customized to
support highest uptime and accuracy
of your instruments.
A Vaisala Service Agreement is
designed to fulfill customer needs
– we will proceed step by step to
find out the most suitable solution
for your application. Let us do the
job and you can concentrate on the
results!
▪
▪
NIST traceable, ISO 9001:2000
5 day turnaround for calibrations
Express service option
ANSI-Z540 and ISO 17025:2005
compliant
r "-"BDDSFEJUBUJPO
r Calibration Reminder Program
provides advance notification when
regular calibration is due.
r FREE one year extended warranty
with calibration
r Spare parts
r Reliable and professional standard
calibrations
Using high quality instruments, the Vaisala Service Center performs calibration and
adjustments in controlled environments.
EXTENDED WARRANTY:
Secure your investment against
accidental breakdowns for
years to come – let Vaisala
carry the risk of unpredictable
repairs. You get all the benefits
of Vaisala’s standard warranty
conditions, but for much
longer.
Vaisala lifetime accuracy
Vaisala’s state-of-the-art Service Center
and Calibration Standards Laboratory
(CSL) provides service, calibration
and adjustment for Vaisala’s relative
humidity, dewpoint, material moisture,
barometric pressure and carbon dioxide instruments.
CALIBRATION REMINDER
PROGRAM:
By joining the Calibration
Reminder Program, you'll
receive a reminder for your
upcoming calibration, along
with detailed information on
how to get the units calibrated
at our service centers.
ISO and A2LA Accreditation
The CSL received from the American
Association for Laboratory Accreditation (A2LA) certification to ISO/IEC
17025:2005. The CSL is also certified to
ISO 9001:2000 and meets the requirements of ANSI/NCSL Z540-1-1994. As a
result the CSL is able to offer accredited calibrations for humidity, dewpoint
and temperature instruments.
REPAIR AND CALIBRATION:
Vaisala Returns On the Web
(ROW) is a system for easy
shipping of Vaisala instruments
for calibration or repair. The
system processes your service
order step-by-step and
produces all required shipping
documents and instructions
needed.
Standard calibration
Calibration is an integral part of instrument maintenance. Vaisala Service
performs multi-point and accredited
calibrations and adjustments to ensure
measurement accuracy.
One-point, on-site field calibrations
are useful in identifying the need for
additional calibration and adjustment.
148
Multi-point calibrations offer the
advantage of high accuracy over the
entire measurement range.
Certificate verifies performance
– both before and after
To verify results, a certificate is issued
for each calibrated instrument. The
certificate shows the readings both
before and after adjustment. This system enables the user to easily monitor the performance of the calibrated
instrument.
Accredited calibration
Accredited calibrations ensure the
highest measurement accuracy and
are directly traceable to international
standards. The measurement uncertainty in accredited calibrations is
presented for all measurement points.
Accredited calibration is recommended for instruments that are used as a
transfer standard, other demanding
measurement applications, and/or to
meet standards.
Calibration Reminder Program
with FREE Extended Warranty
ISO 9001 accreditations are recognized
by major international accreditation
organizations.
2083.01
Vaisala CSL is in compliance with ISO/IEC
17025:2005 and ANSI/NCSL Z540-1-1994
A2LA accreditation.
Quality systems require calibration
tracking. Participants in the Vaisala
Calibration Reminder Program automatically receive a ‘time to re-calibrate’
notice. If the instrument is sent to
Vaisala for recalibration within the initial warranty period, the warranty will
be extended for one year – FREE.
Customer Support
The Vaisala Help Desk, staffed by
technical support engineers, is ready to
provide assistance.
Call: 888.VAISALA (824.7252) or
Email: [email protected]
149
SERVICE
Calibration is Our Core Operation
All Vaisala calibrations comply with ANSI-Z540-1-1994
ISO/IEC 17025:2005 calibrations are also available.
Humidity Calibration
NIST traceable calibrations. Standard calibrations consist
of four points with adjustments at 0% and 75.5% and linearity checked at 11.3% and 33 %RH, (97.6 %RH optional).
Two-pressure generator enables special NIST traceable
calibrations:
r "OZQPJOUTCFUXFFOUP3)
r 5FNQFSBUVSFSBOHFwž'UPž$
Temperature Calibration
r 5FNQFSBUVSFDBMJCSBUJPOTGSPNUPž$
UPž'
r /*45 USBDFBCMF UFNQFSBUVSF DBMJCSBUJPO XJUIJO UIF specified range.
Dewpoint Calibration
r %FXQPJOUDBMJCSBUJPOTGSPNUPž'UPž$
r /*45USBDFBCMFEFXQPJOUDBMJCSBUJPOXJUIJOUIF
specified range.
CO2 Calibration
r $FSUJóFE$02 calibration
r $BMJCSBUJPOBU
0%: 2,000 ppm (0.2%);
3,000 ppm (0.3%);
5,000 ppm; 10,000 ppm; 20,000 ppm
5%: 10% and 20%
Warranty Repair of Vaisala Instruments
For warranty repairs, no authorization from the customer
is needed. Vaisala guarantees a one week turnaround from
the date the instrument(s) are received.
Non-Warranty Repair of Vaisala Instruments
For non-warranty repairs, you will be notified of the
repair charge within one week of the lab receiving the
instrument(s). Vaisala guarantees a one week turnaround
from the authorization date.
Express Service
Two-day guaranteed turnaround service is available for
a nominal fee. When obtaining an RMA number please
inform the Customer Service Representative if this service
is desired.
Maintenance Contracts
Maintenance contracts are available on an individual basis.
Call your sales engineer to discuss the posibilities.
1-888-VAISALA (824-7252)
150
Returning for Service
For service, call Vaisala’s customer service department at
1-800-408-9454.
A Customer Service Representatives will assign an RMA
(Return Material Authorization) number for returning
the Vaisala instrument for recalibration or repair. Please
reference this RMA number on all paperwork, and
write it on the outside of the return package.
Contact Information:
Vaisala North American Service Center
Vaisala Inc.
10-D Gill Street
Woburn, MA 01801
Tel:
781-933-4500
1-888-VAISALA (824-7252)
Fax:
781-933-8029
Customer Service:
Tel:
1-800-408-9454
Email: [email protected]
Technical Support:
Tel:
1-800-408-9456
Email: [email protected]
Web:
www.vaisala.com/reminder
Extend
Your Warranty
for Free!
Standard (factory) Calibrations
Service Center
European Service
Center
Asian Service
Center
North American
Service Center
Location
Helsinki, Finland
Tokyo, Japan
Boston, MA, USA
Humidity
√
√
√
Temperature
√
√
√
Dewpoint
Temperature
√
√
√
Barometric
Pressure
√
√
√
Table 1. Standard (factory)
calibration is available globally
in all Vaisala Service Centers.
Traceability of Measurement Parameters
ISO9001
compliant
ISO17025
compliant
Standard
Calibration
Traceability
Accredited
Calibration
Traceability
Relative Humidity
Yes
NIST
Yes
JCSS/NIST,
Salt Solutions
Temperature
Yes
NIST
Yes
NIST
Dewpoint
Temperature
Yes
NIST, JCSS
Yes
JCSS
Barometric
Pressure
Yes
NIST
Yes
NIST
Carbon Dioxide
Yes
NIST, NMI
Not available
–
Table 2. Traceability of different
measurement parameters.
Accredited Body
Service Center
European Service
Center
Asian Service
Center
North American
Service Center
Location,
Laboratory, Code
Helsinki, Finland,
K008
Tokyo, Japan,
0123
Boston, MA, USA,
112765
Calibration Reminder Program
Accredited Parameters
Register for Vaisala’s Recalibration Reminder
Program and extend your warranty FREE!
Call 1-800-408-9454.
Relative Humidity
√
Temperature
√
Dewpoint
Temperature
Barometric
Pressure
√
√
√
√
√
√
Table 3. Accredited parameters in
Vaisala Service Centers.
151
PRICE LIST
PRICE LIST
FIXED PRICES for CALIBRATION and REPAIR (Effective 1/1/10)
Shipping charges are not included in pricing.
PSERVDA
Digital Repair and Calibration (Class A) ................................................................................................... $395
Order Code:
HUMIDITY: 5 Day Turn-around
PTUSERV
PTU300/PTU200 Repair and Calibration ................................................................................................... $495
RHCALA
2% Standard Calibration* (0, 11, 33, 75% RH)........................................................................................... $150
HMW60/70 wall mount, (0, 33, 75 %RH) .................................................................................................... $100
URGENTFEE
Analog: 2-day turn-around from date unit received....................................................................................... $50
Digital: 2 week turn-around .......................................................................................................................... $95
RHCALD
1% Calibration** (0, 11, 33, 75%RH) .......................................................................................................... $200
Option of 97% available in place of any point or, 5 point including 97% for an additional fee of .................. $75
Oxygen calibration: 4-Week Turn-around
With high end calibration one of the adjustments is done at 97%RH.
OMT355
Calibration 0 - 21% .................................................................................................................................... $330
Resulting accuracy is: ±3 or 2% < 90 %RH and ± 2 or 1% > 90 %RH.
OMT355
Calibration 0- - 100% ................................................................................................................................. $622
COMBOCAL
Combination Calibration (5-point RH Cal 0, 11, 33, 75, 97 + 3-point Temp Cal 0°, 50°, 100 °C)................$425
DTS1 Calibration:
RHSERVA
RHSERVD
Repair and 2% Calibration* ....................................................................................................................... $250
Repair and 1% Calibration (Non Sensing Head Units) ............................................................................... $500
DTSCAL
DTS1SERV1
Calibration
....................................................................................................................................... $ 200
Calibration & sensor replacement (Minor Repair) ...................................................................................... $500
RHSERVD-SHC Repair and 1% Calibration** (Sensing head included) ............................................................................... $600
DTS1SERV2
Calibration & Major Repair ......................................................................................................................... $700
ANALOGCAL1
Forced output, 3-points at min, mid, max of scaling.....................................................................................$100
ANALOGCAL2
Actual values measured on outputs during calibration............................................................. ...................$100
RHCALPOINT
Special Humidity including certificate (11%…95% @ 0…70 °C):
ambient (Room Temperature) ......................................................................... $95
elevated temperatures .................................................................................. $150
2 Day Express Service (on RHCALA & RHCALD only) per unit (Not available on dewpoint products,
Accreditation/ or special points.) ................................................................................................................ $50
.......................................................................................................................................................................$100
URGENTFEE
EVALUATION
* The Standard Calibration consists of a 4 point calibration with adjustments made at 0% and 75.5% and linearity checked at
11.3% and 33%. Temperature is verified at ambient.HMP42 Repair is RHSERVD
** 1% Calibration is standard for the HMP230 Series, HMP240 Series, HMP260 Series, HMI38 with HMP35E/36E/37E,
HMT360 Series, HMI41/HMP46, HMT330 Series and HMP70 Series.
ISO 17025 Accredited Calibrations for Humidity, Temperature, Dewpoint and Pressure - See pages 202-209
TEMPERATURE: 5-7 Day Turn-around: includes certificate
Calibration per point; minimum 2 points (range -80 °C …180 °C based on model) .................................... $75
Temperature Respanning for HMD/W 20/30, 60/70,& 61/71 units ................................................................ $50
sTemperature spans must be 40 °C (72 °F) apart for HMD/W 20/30, HMD/W60/70, and 61/71 units
CARBON DIOXIDE: 5 Day Turn-around
Calibration (Zero and Span) (2000, 3000, 5000, 10,000, 20,000 PPM …1, 2, 3, 5, 10, 20%) ................... $125
Repair and Calibration ............................................................................................................................... $250
Calibration of GMP220 probes (3 points) ................................................................................................... $200
TCAL
RESPAN
CO2CAL
CO2SERV
CO2CALIND
CO2SERVIND
216873
217084
216880
DEWAL-STD
DEWCAL
DEWCAL5
DEWSERV
DEWSERV5
Repair and Calibration of GMP220 probes ................................................................................................. $400
GM70 Pump Service ................................................................................................................................. $600
GMP343 Calibration (4-week turn-around) ................................................................................................ $350
GMP343 Repair (4 week trun-around) ...................................................................................................... $650
DEWPOINT: 5 to 10 Day Turn-around; includes certificate
3 point calibration (-50, -30, +10 °C) Production Calibration Points ........................................................... $300
3 point calibration (-40, -30, -20 °C) (Range -70…+20 C°)......................................................................... $300
NOTE: $100 per point for -70…+20°C, $125 per point for +20…60 °C
5 point calibration (-50, -40, -30, -20, -10 °C) ............................................................................................ $450
3 point repair and calibration (-40, -30, -20 °C) ......................................................................................... $600
5 point repair and calibration (-50, -40, -30, -20, -10 °C) ........................................................................... $700
s$%7#!,#ALIBRATIONISSTANDARDFORTHE$-0AND$-4
PCALDB
PSERVA
200
152
PRESSURE: Digital 3 Week Turn-around; Analog 1 Week Turn-around includes certificate
Analog Calibration (Class B, 1 week turn-around) ..................................................................................... $125
Analog Repair and Calibration (Class B) ................................................................................................... $400
PTB100A, PTB101C & PTA427, 6 point calibration @ 800, 850,900,950,1000,1050 hPa
PTB100B & PTB101B, 8 point calibration @ 600, 700, 800, 850, 900,1000, 1050 hPa
Prices in U. S. dollars. Prices are subject to change without notice. A 25% restocking fee for returned products.
WIND: 3 Week Turn-around
WSSERV
Upgrades and Software WXT510 & WS425 ............................................................................................... $250
Mechanical Sensors .................................................................................................................................. $600
Ultrasonic Sensors - Evaluation ................................................................................................................ $100
Ultrasonic Sensors - Repair ....................................................................................................................... $750
WXT and WMT50 - Functional testing and/or PTU replacement................................................................ $250
WXT520 Service/WXT510 upgrade to WXT520 ........................................................................................ $450
NOTE: WS425 units with orange transducers cannot be repaired.
UNIT UPGRADES:
Upgrade to All Parameters Version (Software): ......................................................................................... $600
Upgrade HUMICAP from an H180 sensor to H180R sensor ..................................................................... $400
Upgrade HUMICAp from an H180C sensor to H180RC sensor ................................................................ $600
Adding Display/Keypad:
HMT330 Series any single upgrade (i.e. software/display and analog channel) ........................................ $600
HMP230 Series ......................................................................................................................................... $600
HMT100 Display ........................................................................................................................................ $500
HMT360 Series .......................................................................................................................................... $600
GMT220 Series ......................................................................................................................................... $400
PTB220, PTB330, PTU300 Series ............................................................................................................ $600
Adding Second Channel:
HMT360 Series........................................................................................................................................... $600
NOTE: All prices listed above include RH Calibration and Certificate
Adding Data Logging or w/LANMofule
Unit w/5.0SW ............................................................................................................................................. $600
Unit w/4.0SW .............................................................................................................................................. $800
Adding Analog Output Option:
PTB220, (Sent to Helsinki) PTB330, PTU300 .......................................................................................... $600
NOTES:
Pricing:
Prices are subject to change without notice. All prices are FOB Woburn, MA.
Shipments:
Express Service, for next day shipments (if available) $50.
Returns/Restocking:
Unless otherwise noted on the Order Guides, standard unused products if
resaleable as new, can be returned within 90 days of purchase with a Return
Materials Authorization (RMA).
A 25% restocking fee will be charged for all returned products.
Service Repairs:
A Return Material Authorization (RMA) is necessary prior to sending products to
Vaisala for repair.
Vaisala, Inc.
10-D Gill Street
Woburn, MA 01801
Toll Free: 888-VAISALA (824-7252)
Tel: 781-933-4500
Fax: 781 933-8029
Customer Service
Toll Free: 1-800-408-9454
Email: [email protected]
Technical Support
Toll Free: 1-800-408-9456
Email: [email protected]
Prices in U. S. dollars. Prices are subject to change without notice. A 25% restocking fee for returned products.
201
153
www.vaisala.com
DMT132 Dewpoint Transmitter
for Refrigerant Dryers
Features / Benefits
▪
Affordable dew point
transmitter for refrigerator
dryers
▪
High accuracy ±1°C (±1.8°F)
in the measurement range of
refrigerator dryers
▪
Excellent long-term stability resistant to compressor oil and
most other chemicals thanks to
HUMICAP® technology
▪
Low power requirements,
10 .... 28 VDC
▪
Easy to verify functionality with
compatible hand-held meters
DM70 or HM70
▪
Optional LED warning light
The optional LED warning light tells the user when the defined dew point limit has
been exceeded.
The Vaisala HUMICAP® Dewpoint
Transmitter DMT132 is an affordable
dew point measurement instrument
designed to verify the functionality of
refrigerant dryers. It is especially well
suited for OEM dryer manufacturers.
Direct measurement
cuts costs
Direct outlet air dew point
measurement provides accurate
information about dryer functionality
and is more reliable than the
traditional method of measuring
refrigerator temperature only.
Knowledge of the real dew point
ensures high quality compressed air
at all times and enables customers to
optimize dryer capacity. This helps
to prevent investment in redundant
dryer capacity and avoid unnecessary
maintenance and costly malfunctions.
High accuracy and
long-term stability
The DMT132 provides optimal
performance in the operating range of
refrigerant dryers. In the measurement
range of -3… 20°C (+26.6…+68°F), where
the refrigerator dryers typically
operate, the Td accuracy is ±1°C (±1.8°F).
The instrument incorporates the
proven Vaisala HUMICAP® sensor,
which is resistant to compressor oil
and most other chemicals, thereby
providing excellent long-term stability.
DMT132 operating voltages can be as
low as 10 VDC.
Verifying the performance of the
DMT132 is easy with the compatible
Vaisala hand-held DM70 or HM70
meters. The user can perform
possible adjustments with the Vaisala
HMK15 Humidity Calibrator.
Quick installation and
easy field checking
It takes just a few minutes to install
the DMT132 directly into a dryer or
compressed air line through a G1/2”
ISO thread. Vaisala sampling cells
can also be used. The loop-powered
electronics mean that wiring is easy
and power requirements are low.
Demand for dew point sensors to verify
refrigerant dryers is increasing. Direct
dew point measurement enables energy
savings and improved efficiency.
Technical data
Performance
General
Dewpoint
Sensor
Vaisala HUMICAP®180R
Recommended calibration interval
2 years
(in refrigerant dryer application)
Mechanical connection
G 1/2" ISO
Operating voltage
10 .... 28 VDC
External load
max 100 ohm for supply voltages <20 VDC
max 500 ohm for supply voltages 20...28 VDC
Weight
65 g (2.3 oz)
Housing material
PPS + 40% GF
Housing classification
IP65 (NEMA 4)
Storage temperature range
-40 ... + 80 °C (-40 ... +176 °F)
Start-up time
3s
Complies with EMC standard EN61326-1, Electrical equipment
for measurement control and laboratory use - EMC requirements;
Industrial environment
Measurement range
-20 ... +50 °C (-4 ... +122 °F) Td
Accuracy (at +20 °C (+68 °F)) ±1 °C for -3...20 °C (+26.6 ... +68 °F) Td
±2 °C for -15...-3 °C (+5 ... +26.6 °F) Td
see accuracy graph below
* when dewpoint is below 0 °C (+32 °F), the transmitter outputs
frostpoint
Response time at 20 °C (+68 °F) gas temperature and 1 bar pressure
-20 -> +50 °C (-4 -> +122 °F) Td
17 s (63%)
40 s (90%)
+50 -> -20 °C (+122 -> -4 °F) Td
33 s (63%)
85 s (90%)
Calculated variables
Dewpoint converted to atmospheric pressure
Tdf atm
Dewpoint temperature (°C)
60
50
Options and accessories
40
30
20
Accuracy
±1 °C
10
0
Accuracy
±2 °C
-10
-20
-30
-10
0
10
20
30
40
50
60
Temperature of measured gas (°C)
Operating environment
Operating temperature
Operating pressure
Relative humidity
Sample flow rate
Measured gases
-10 ... + 60 °C (+14 ... +140 °F)
0 ... 20 bar
0 ... 100 %RH
no effect on measurement accuracy
non-corrosive gases
Tube filter
230602
Special cover set for HMK15 (calibrator fitting
DMT132 and HMP60)
230914
NPT Adapter
210662SP
Sample cells
DMT242SC, DMT242SC2, DSC74, DSC74B,
DSC74C, DMCOIL
Duct installation flange
DM240FA
Cables (several lengths
HMP50Z032, HMP50Z300SP,
available)
HMP50Z500SP, HMP50Z1000SP
Loop powered external display
226476
USB Service cable
219690
Connection cable to DM70/HM70
219980
LED plug
230388
ISO" 1/2 plug
218773
NPT1/2" plug
222507
Sealing ring set (3 pcs U-seal)
221525SP
Outputs
For more information, visit
www.vaisala.com or contact
us at [email protected]
80.5
6
125.5
45
2.5
12
AW 30
R1
9.5
33
Analog output (scalable)
4...20 mA, 2-wire
Resolution for current output
0.002 mA
Accuracy of analog outputs at +20 °C
±0.05% full scale
Typical temperature dependence
±0.005% of full scale/ °C
Connector
4-pin M8( (IEC 60947-5-2)
LED indication available for defined dewpoint limit/ error state
indication
RS485 serial line for service use
G1/2" ISO 228-1
Ref. B211105EN-A ©Vaisala 2011
36
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
Accredited Humidity & Temperature Calibration
ACCREDITED HUMIDITY CALIBRATION
The relative humidity calibration is performed at room
temperature using a Thunder Scientific 2500 TwoPressure Generator. The calibration uncertainty
typically ranges from ± 0.60 to ±1.1 %RH. A onepoint temperature calibration is performed at ambient.
The calibration procedure used for calibrations is
11603108-CSL Humidity Calibration.
Ordering a calibration that complies with the requirements of ISO/IEC 17025:2005
Calibration for Vaisala humidity and temperature transmitters and probes can easily be ordered using this
form. Please read the form and notes carefully and complete the form accurately to ensure correct
calibration service. The form must be completed in full before calibration services can start. Include the
form with your instrument. For additional information please contact Vaisala at 1-800-408-9454.
Instrument Details
Customer Name:
Thunder Scientific 2500 Two-Pressure Generator
saturates a continuous stream of gas with water vapor
at a known pressure and temperature, and passes it
through an expansion valve where it expands to a
lower pressure.
ACCREDITED TEMPERATURE CALIBRATION
The temperature calibration is made using Hart
Scientific liquid bath with a Black Stack reference.
The calibration uncertainty is typically ±0.02 °C. The
calibration procedure used for calibration is 11603135CSL Temperature Calibration.
Hart Scientific liquid baths are used as the calibration
method. A Hart Scientific Black Stack/PRT
combination is used as the reference standard. The
Black Stack uses a high accuracy display module,
model 1560 as the readout indicator. The PRT is
immersed in the liquid of the bath.
CALIBRATION DETAILS
The instrument will be adjusted to comply with its
specifications (if needed) unless no adjustment is
requested. Out of tolerance conditions are determined
by the product specification only. The calibration
Model No(s):
Serial No(s):
Calibration Laboratory Certificate #: 2083.01
ISO/IEC 17025:2005
CALIBRATION DETAILS CONTINUED
uncertainty is not tied in with the instrument's
accuracy. All results are reported in a calibration
certificate, which is written according to the ISO/IEC
17025:2005 standard.
ACCREDITATION
Accreditation is a third party formal recognition that
a laboratory is competent to carry out specific
calibrations.
The American Association for Laboratory
Accreditation (A2LA) has assessed Vaisala’s
Calibration Standards Laboratory (CSL) for humidity
and temperature calibrations. The accreditation
standard used is ISO/IEC 17025:2005. A2LA
accreditation is recognized by all the major
international accreditation organizations.
Calibration Details
Price
Humidity Calibration
Performed at ambient temperature. Includes 1-point ambient temperature calibration.
Extra points are $95 each (example: 7 points = $545). Please specify custom points below.
0 Points
A
B
C
D
E
No Humidity Calibration
4 Points
0, 11, 50, and 80 %RH
6 Points
0, 11, 30, 50, 70, and 90 %RH
8 Points
0, 11, 30, 50, 60, 70, 80, and 90 %RH
10 Points
0, 11, 30, 40, 50, 60, 70, 80, 90, and 95 %RH
SI – International System of Units
SI – International System of Units
National
Level (USA)
National Institute of Standards and
Technology (NIST)
National Institute of Standards and
Technology (NIST)
CSL Primary Standard: MBW
Chilled Mirror Hygrometer
Hart Scientific
$0.00
$325.00
$450.00
$600.00
$750.00
Temperature Calibration - Specify Points Below
Test points must be between -80 °C and 180 °C and within the model’s measurement range.
0 Points
No Temperature Calibration
3 Points
1_____ 2_____ 3_____ °C / °F
5 Points
1_____ 2_____ 3_____ 4_____ 5_____
7 Points
1_____ 2_____ 3_____ 4_____ 5_____ 6_____ 7_____
9 Points
1_____ 2_____ 3_____ 4_____ 5_____ 6_____ 7_____ 8_____ 9_____ °C / °F
°C / °F
°C / °F
A
B
C
D
E
$0.00
$225.00
$350.00
$450.00
$550.00
Units of Results Reported
A
B
Humidity %RH, Temperature °C
International
Level
Secondary
Level
Accredited Humidity & Temperature Calibration
Humidity %RH, Temperature °F
$0.00
$0.00
Adjustment
Calibration prices include adjustment (if needed). Check here if you DO NOT want your instrument adjusted.
Customer Information To Appear On Certificate
Company Name (if different than above):
Address:
CSL Primary Std.: Hart Scientific
Super-Thermometer/SPRT
CSL Standard: Thunder Scientific
2500 Generator
CSL Standard: Hart Scientific
Black Stack/PRT
Requested Due Date For Next Calibration:
Customer Asset #:
Received And Accepted At Vaisala
Customer
Level
Calibration for Customer
Working Standards
Calibration for Customer
Working Standards
Traceability chain for humidity calibration
Traceability chain for temperature calibration
11604121 – Rev. B
154
Name & Date:
Contract #:
NOTE: The calibration prices include a Calibration Certificate, but do not reflect repair charges.
Repair charges will utilize fixed pricing: Analog repairs: $125.00, Digital repairs: $350.00
11604121 – Rev. B
155
Accredited Dewpoint Calibration
Accredited Dewpoint Calibration
Ordering a calibration that complies with the requirements of ISO/IEC 17025:2005
Calibration for Vaisala humidity and temperature transmitters and probes can easily be ordered using this
form. Please read the form and notes carefully and complete the form accurately to ensure correct
calibration service. The form must be completed in full before calibration services can start. Include the
form with your instrument. For additional information please contact Vaisala at 1-800-408-9454.
ACCREDITED DEWPOINT CALIBRATION
The dewpoint calibration is made using a Thunder
Scientific 3900 Two-Pressure Generator at room
temperature. The calibration uncertainty is
typically from 0.2 oC. A one-point temperature
calibration is performed at ambient. The
calibration procedure used for calibration is
11603134-CSL Dewpoint Calibration.
The Thunder Scientific 3900 Two-Pressure TwoTemperature Generator saturates a continuous
stream of air or nitrogen with water vapor at a
known pressure and temperature. The saturated
high-pressure gas then passes through an
expansion valve where it expands to a lower
pressure. To generate a particular humidity the
3900 first selects a suitable saturation temperature.
It then determines the saturation pressure required
to establish the correct saturation vapor pressure.
CALIBRATION DETAILS
The instrument will be adjusted to comply with
its specifications (if needed) unless no adjustment
is requested. Out of tolerance conditions are
determined by the product specification only. The
calibration uncertainty is not tied in with the
instrument's accuracy. All results are reported in a
calibration certificate, which is written according
to the ISO/IEC 17025:2005 standard.
International
Level
Instrument Details
Customer Name:
Model No(s):
Calibration Laboratory Certificate #: 2083.01
ISO/IEC 17025:2005
ACCREDITATION
Accreditation is a third party formal recognition
that a laboratory is competent to carry out
specific calibrations.
The American Association for Laboratory
Accreditation (A2LA) has assessed Vaisala’s
Calibration Standards Laboratory (CSL) for
humidity and temperature calibrations. The
accreditation standard used is ISO/IEC
17025:2005.
A2LA accreditation is recognized by all the
major international accreditation organizations.
Serial No(s):
Calibration Details
Price
Dewpoint Calibration - Specify Points Below
Dewpoint points must be between -60 °C and -10 °C and within the model’s measurement range.
3 Points
1:______ 2:______ 3:______
4 Points
1:______ 2:______ 3:______ 4:______
5 Points
1:______ 2:______ 3:______ 4:______ 5:______
A
B
C
$500.00
$625.00
$750.00
Units of Results Reported
A
B
Humidity %RH, Temperature °C
Humidity %RH, Temperature °F
$0.00
$0.00
Adjustment
Calibration prices include adjustment (if needed). Check here if you DO NOT want your instrument adjusted.
Customer Information To Appear On Certificate
Company Name (if different than above):
Address:
SI – International System of Units
Requested Due Date For Next Calibration:
National
Level (USA)
Secondary
Level
National Institute of Standards and
Technology (NIST)
CSL Primary Standard: MBW
Chilled Mirror Hygrometer
CSL Standard: Thunder Scientific
3900 Generator
Customer
Level
Customer Asset #:
Received And Accepted At Vaisala
Name & Date:
Contract #:
NOTE: The calibration prices include a Calibration Certificate, but do not reflect repair charges.
Repair charges will utilize fixed pricing: Analog repairs: $125.00, Digital repairs: $350.00
Calibration for Customer
Working Standards
Traceability chain for dewpoint calibration
11604122 – Rev. B
156
11604122 – Rev. B
157
Vaisala Filters
Vaisala Filters continued
Group A: 12 mm Diameter, Standard Length, Female Threads
Group C: 12 mm Diameter,
0195
Brass, sintered filter, 133 microns, ø 12.0 mm
Use with: HMM20/30, HMP130,HMP36,
HMP46
Group: A
0195
Male Threads
17039HM
Membrane filter 0.2 μm, ø 12 mm
Use with: HMD60/70/40/50
HMP44, HMP141/143
Group: C
10159HM
Membrane filter, 0.2 microns, ø 12.0 mm
Use with: HMD20/30, HMM20/30, HMP133,
HMP75, HMM100
Group: A
17039HM
10159HM
DRW010522
HM46670SP
Sintered stainless steel filter , 38 μm,
ø 12.0 mm
Use with: HMP50, HMM210, HMT100,
HMD60/70
Group: C
6221
Plastic grid, 2 mm protection, ø 12.0 mm
Use with: HM34,
HMD20/30,HMM20/30,HMP133, HMP75,
HMM100
Group: A
6221
HMM46670SP
Group B: 12 mm Diameter, Long Length, Female Threads (Could be used in place of “A” type filters)
Group D: 13.5 mm Diameter, Male Threads
DRW010276SP
PPS plastic grid filter, 6.5 mm, ø 12 mm
Use with: DTS1, HMT330, HMP76/77, MMT310
Group: B
DRW010276SP
HM47280SP
Stainless steel sintered filter , 38 μm, ø 12mm
Use with: HMT330, HMP76/77, DM70, DMT242,
DMP74, DMT142,HMM20/30, MMT310,
DMT340, HMM100
Group: B
DRW212987SP
Sintered filter, 40 μm, ø 12 mm
Use with: HMP76/77, HMP75
Group: B
DRW010525
17230HMSP
PTFE membrane, 3.5 μm, ø 13.5 mm.
Use with: HMP230, HMP228, HMT360
Group: D
17230HMSP
16562SP
PPS Grid, 2 mm, ø 13.5 mm
Use with: HMP230, HMP37, HMP228, HMT360,
PTU200
Group: D
HM47453SP
Stainless steel filter guard for vacuum,
3.15 mm, ø 12 mm
Use with: DM70, DMT242, HMP228, DMT340,
HMT310, MM70, MMT310, DMT142, MMT330
Group: B
HM46999SP
Sintered stainless steel filter, 2mm, ø 13.5
Use with: DMP248, HMT360, HMP237
Group: D
HM46999SP
16562SP
HM47453SP
DRW010525
Membrane filter, 0.2 μm, ø 12 mm
Use with: HMW61/71 Internal
HMD60/70, HMP50, HMT100
Group: C
16452SP
Sintered filter, stainless steel, 37
microns, ø 13.5 mm
Use with: DMP248, HMP230, HMP228,
HMT360
Group: D
16452SP
HM47280SP
DRW010281SP
PPS plastic grid with stainless steel nettng,
15 μm, ø 12 mm
Use with: DTS1, HMT330, HMP76/77, MMT310
Group: B
DRW010281SP
DRW010522
Plastic Grid, 2 mm, ø 12 mm
Use with: HMP50, HMT100
Group: C
16720HMSP
PPS Grid and stainless steel net, 14 μm,
ø 13.5 mm
Use with: HMP230, HMT360, HMP37E
Group: D
219452SP
Sintered PTFE filter, ø 12 mm
Use with: HMP155, HMM100
Group: B
16720HMSP
DRW212987SP
158
219452SP
159
Order Guides
Vaisala Filters continued
Order Guides
HMT331 Humidity and Temperature Transmitter
For wall mounting
Group E: 18.5 mm Diameter, Female Threads
1
2
2787HM
Membrane filter, 0.2 microns, ø 18.5 mm
Use with: HMM30, HMP35,HMP45,PTU200,
HMW21/31
Group: E
6597
Plastic grid, 2.5 mm, ø 18.5 mm
Use with: HMM30N,HMP131, HMP35,
HMP45A/D
Group: E
3
4
5
6
7
6597
2787HM
HM46717
Plastic grid, 2.5 mm, ø 18.5 mm
Use with: HMP41, HMP45
Group: E
16126HM
Metallized membrane filter, 0.5 μm, ø 18.5 mm
Use with: HMP35
Group: E
16126HM
HM46717
8
9
10
11
HM47329
Probe cap, ø 18.5 mm (protective cap)
Use with: HMT100
HM47329
12
Output units
13
Option for module slot 1
14
Stand Alone - Not Interchangeable:
HM46780
Stainless steel filter, 38 μm, ø 20 mm
Use with: DMP246CS - External
19858HM
Membrane filter tube set (5 pcs)
HMP42 aprobe,
0.2 μm, ø 4mm
Steel grid for the HMP42 probe,
1 mm, ø 4 mm
Option for module slot 2
15
Cable bushings
16
Transmitter installation
17
19867HM
1 2 3 4 5 6
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330
1 A 0
Transmitter type
HMT331
1
Wall probe fixed
Cable length
A
with short cable Probe holder plate recommended in selection 16
8
No additional temperature probe
0
Parameters
RH+T
A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
B
Display
No display
0
Graphic display with keypad
1
Power supply
10...35 VDC , 24 VAC
(HMT300PWS)
0
Galvanic isolation for outputs 10...35 VDC, 24 VAC
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
+ Serial interface RS232 or optional communication module
Analog output signals
No 3rd analog output
for Ch1 , Ch2 and Ch3
RH
(0...100%RH)
RH=relative humidity
T
(range: see below)
T=temperature
Td (-20...100°C)
(-4...+212 °F)
Td=dewpoint
Tdf (-20...100°C)
(-4...+212 °F)
Tdf = dewpoint/ frost point temperature
a=absolute humidity
a (0...600g/m3)
(0...262 gr/ft3)
Tw (0...100°C)
(+32...+212°F)
Tw=wet bulb temperature
x=mixing ratio
x (0...500g/kg d.a)
(0...3500gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
h=enthalpy
ppm (0…5000)
(0…5000)
ppm=parts per million
pw=water vapor pressure
pw (0…1000 hPa)
(0…14.5psi)
pws (0…1000 hPa)
(0…14.5psi)
pws=saturation water vapor pressure
dT (-10...+50 °C)
(14...+122 °F)
dT=(temperature-dewpoint temperature)
SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________
Define scale
Ch1:_______________ Ch2:________________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A if not needed
Analog output range
No temperature output
(-40...+140°F)
for temperature
-40...+60°C
(-4...+140°F)
Note:
-20...+60°C
- Choose option A, if no
(+32...+140°F)
0...+60°C
T output is desired
Special
:_______________________
Humidity sensor type
18
Sensor protection
19
20
No probe installation kit
Operating manual
language
PC Accessories
HM46780
21
22
23
Calibration
For future use
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A 1
$360
$320
$80
$200
$210
$60
1
2
3
4
5
B
C
D
E
F
G
H
J
K
L
M
N
X
B
C
D
E
F
G
H
J
K
L
M
N
X
Metric
Non-metric
No module
Relay output
(Relay-1)
RS-485 serial interface (galvanically isolated)
(RS485-1)
LAN (Ethernet) interface + 2 m cable (RJ45)
Not with universal AC power
WLAN (Wireless Ethernet) interface + antenna
with short cable probe only
Data logger module
No module
Relay output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
Data logger module
Not possible if the data logger module has already been chosen in item 11
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
8-pole connector with 5 m cable (not possible with universal AC power option)
(212142)
(212416)
8-pole counter connector equipped with screw terminals (not possible with universal AC power option)
Standard wall mounting
Adapter plate (for replacing the HMP230's)
(214829)
Pole installation kit
(215108)
DIN rail kit
(215094)
Probe holder plate
Recommended with short cable probe
(226252)
General purpose
HUMICAP180
Chemical purge
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180R
Chemical purge
HUMICAP180RC
PPS plastic grid & stainless steel netting
(DRW010281SP)
PPS plastic grid
(DRW010276SP)
Sintered stainless steel filter
(HM47280SP)
A
B
C
D
E
F
G
H
J
K
L
M
N
X
A
B
F
K
X
1
2
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
A
B
C
D
$60
$60
0
1
2
4
5
$90
$100
$90
$90
1
4
A
C
$60
$60
A
B
C
A
No manual
English
No
Service cable for PC, RS232
MI70LINK software for Windows® with RS232 service cable
Service cable for PC, USB with software driver
MI70LINK software for Windows® with USB service cable
ISO9001 compliant calibration with NIST traceable certificate
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
(M210566EN)
(19446ZZ)
(215005)
(219685)
(219916)
A
B
A
B
C
D
E
$40
$60
$90
$90
A
1
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
HMT330
1 A 0 A 1 0 1 B C A B 2 0 0 A 0 A A A B A A
160
PRICE
$1,120
1
161
HMT333 Humidity and Temperature Transmitter
HMT334 Humidity and Temperature Transmitter
For general use
1
2
3
4
5
6
7
8
9
10
11
For pressurized processes
1 2
3
3
E
F
G
4
5
6
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A 1 PRICE
$1,170
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330
Transmitter type
HMT333
Cable length
2 m cable +80 °C
5 m cable +80 °C
10 m cable +80 °C
2 m cable +120 °C
5 m cable +120 °C
10 m cable +120 °C
No additional temperature probe
0
Parameters
RH+T
A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
B
Display
No display
0
Graphic display with keypad
1
Power supply
10...35 VDC , 24 VAC
(HMT300PWS)
Galvanic isolation for outputs 10...35 VDC , 24 VAC
(DcDc-1)
Universal AC -power (100....240 VAC)
(Power-1)
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991)
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
+ Serial interface RS232 or optional communication module
Analog output signals
No 3rd analog output
for Ch1 , Ch2 and Ch3
RH
(0... 100%RH)
RH=relative humidity
T
(range: see below)
T=temperature
Td (-20...100°C)
(-4...+212 °F)
Td=dewpoint
Tdf (-20...100°C)
(-4...+212 °F)
Tdf = dewpoint/ frost point temperature
a=absolute humidity
a (0...600g/m3)
(0...262 gr/ft3)
Tw (0...100°C)
(+32...+212°F)
Tw=wet bulb temperature
x=mixing ratio
x (0...500g/kg d.a)
(0...3500gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
h=enthalpy
ppm (0…5000)
(0…5000)
ppm=parts per million
pw=water vapor pressure
pw (0…1000 hPa)
(0…14.5psi)
pws (0…1000 hPa)
(0…14.5psi)
pws=saturation water vapor pressure
dT (-10...+50 °C)
(14...+122 °F)
dT=(temperature-dewpoint temperature)
SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________
Define scale
Ch1:_______________ Ch2:________________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A if not needed
Analog output range
No temperature output
(-40...+176°F)
for temperature
-40...+80°C
-40…+120 °C (-40…+248 °F)
Note: Choose Option A,
Other:
Specify range:____________________
$150
$300
$220
$360
$540
Output units
13
Option for module slot 1
14
15
16
17
18
19
20
21
22
23
Option for module slot 2
Cable bushings
Transmitter installation
Humidity sensor type
Sensor protection
Installation kit
for probe
Operating manual
language
PC Accessories
Calibration
For future use
Metric
Non-metric
No module
Relay output
RS-485 serial interface (galvanically isolated)
Not with universal AC power
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logger module
No module
Relay output
3rd Analog output
Choose also analog output signal for Ch3
Data logger module
Not possible if the data logger module has already been chosen in item 11
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
Conduit fitting for wire conduit (NPT1/2")
8-pole connector with 5m cable (not possible with Universal AC power option)
8-pole counter connector equipped with screw terminals (not possible with Universal AC power option)
Standard wall mounting
Adapter plate (for replacing the HMP230's)
Pole installation kit
Pole installation kit with rain shield
DIN rail kit
General purpose
Chemical purge
General purpose and high chemical concentrations
Chemical purge
PPS plastic grid & stainless steel netting
PPS plastic grid
Sintered stainless steel filter
No kit
Duct installation kit
Cable gland AGRO
No manual
English
No
Service cable for PC, RS232
MI70LINK software for Windows® with RS232 service cable
Service cable for PC, USB with software driver
MI70LINK software for Windows® with USB service cable
ISO9001 compliant calibration with NIST traceable certificate
5
6
$320
0
1
2
3
9
$80
$200
$210
$60
7
1
2
3
4
5
B
C
D
E
F
G
H
J
K
L
M
N
X
B
C
D
E
F
G
H
J
K
L
M
N
X
A
B
C
D
E
F
G
H
J
K
L
M
N
X
8
9
10
11
A
C
D
X
1 2 3 4 5 6
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330
4
0
HMT334
Transmitter type
4
Cable length
2 m cable
H
5 m cable
J
10 m cable
K
No additional temperature probe
0
Parameters
RH+T
A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
B
Display
No display
0
Graphic display with keypad
1
Power supply
10...35 VDC , 24 VAC
(HMT300PWS)
0
Galvanic isolation for outputs 10...35 VDC , 24 VAC
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
+ Serial interface RS232 or optional communication module
Analog output signals
No 3rd analog output
for Ch1 , Ch2 and Ch3
RH
(0... 100%RH)
RH=relative humidity
T
(range: see below)
T=temperature
Td (-20...100°C)
(-4...+212 °F)
Td=dewpoint
Tdf (-20...100°C)
(-4...+212 °F)
Tdf = dewpoint/ frost point temperature
a=absolute humidity
a (0...600g/m3)
(0...262 gr/ft3)
Tw (0...100°C)
(+32...+212°F)
Tw=wet bulb temperature
x=mixing ratio
x (0...500g/kg d.a)
(0...3500gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
h=enthalpy
ppm (0…5000)
(0…5000)
ppm=parts per million
pw=water vapor pressure
pw (0…1000 hPa)
(0…14.5psi)
pws (0…1000 hPa)
(0…14.5psi)
pws=saturation water vapor pressure
dT (-10...+50 °C)
(14...+122 °F)
dT=(temperature-dewpoint temperature)
SPECIAL
Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________
Define scale
Ch1:_______________ Ch2:________________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A, if not needed
Analog output range
No temperature output
(-40...+356°F)
for temperature
-40...+180°C
Note: Choose Option A,
Other:
Specify range:____________________
12
Output units
13
Option for module slot 1
1
2
0
1
2
4
5
6
(Relay-1)
(RS485-1)
$180
$160
$260
$320
$350
0
1
3
6
(Relay-1)
(AOUT-1)
(214728SP)
(214780SP)
(212142)
(212416)
$180
$160
$350
A
B
C
D
(214829)
(215108)
(215109)
(215094)
HUMICAP180
HUMICAP180C
HUMICAP180R
HUMICAP180RC
(DRW010281SP)
(DRW010276SP)
(HM47280SP)
(M210566EN)
Cable bushings
Note: The Universal AC
power not connected
Transmitter installation
$60
$60
0
1
2
3
4
$90
$100
$110
$90
1
4
A
C
17
Humidity sensor type
18
Sensor protection
19
Installation kit
for probe
Operating manual
language
PC Accessories
$60
$60
A
B
C
20
$80
$50
21
$40
$60
$90
$90
22
23
A
B
A
1
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
HMT330
3 E 0 A 0 0 1 B C A C 2 0 0 A 0 A A A B A A
Order Code
DTR502B
15
Option for module slot 2
through 8 pole connector.
A
B
C
D
E
(19446ZZ)
(215005)
(219685)
(219916)
14
16
A
C
D
(210697)
(HMP247CG)
Additional Accessories: Description
Outdoor Solar Radiatioin Shield
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A 1 PRICE
$2,240
$160
$370
$360
$320
$80
$200
$210
$60
1
2
3
4
5
B
C
D
E
F
G
H
J
K
L
M
N
X
B
C
D
E
F
G
H
J
K
L
M
N
X
A
B
C
D
E
F
G
H
J
K
L
M
N
X
A
E
X
if no T output is desired
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
162
3
4
$360
if no T output is desired
12
1
2
Calibration
For future use
Metric
Non-metric
No module
Relay output
(Relay-1)
RS-485 serial interface (galvanically isolated)
(RS485-1)
Not with universal AC power
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logger module
No module
Relay output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
Data logger module
Not possible if the data logger module has already been chosen in item 11
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
(212142)
8 pole connector with 5 m cable
(212416)
8 pole connector supplied with screw terminals
Standard wall mounting
(214829)
Adapter plate (for replacing the HMP230's)
(215108)
Pole installation kit
DIN rail kit
(215094)
General purpose
HUMICAP180
Chemical purge
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180R
Chemical purge
HUMICAP180RC
PPS plastic grid & stainless steel netting
(DRW010281SP)
PPS plastic grid
(DRW010276SP)
Sintered stainless steel filter
(HM47280SP)
Stainless steel grid
(HM47453SP)
Fitting body M22 x 1,5
(17223)
Fitting body NPT 1/2"
(17225)
No manual
(M210566EN)
English
No
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable
(215005)
(219685)
Service cable for PC, USB with software driver
MI70LINK software for Windows® with USB service cable
(219916)
ISO9001 compliant calibration with NIST traceable certificate
1
2
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
A
B
C
D
$60
$60
0
1
2
4
$90
$100
$90
1
4
A
C
$60
$60
A
B
C
D
E
F
A
B
A
B
C
D
E
A
1
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings:
HMT330 4 H 0 A 0 0 1 B C A E 2
$40
$60
$90
$90
0 0 A 0 A C F
B A A
1
1
PRICE
$310
163
1
2
3
4
5
6
7
8
9
10
11
HMT335 Humidity and Temperature Transmitter
HMT337 Humidity and Temperature Transmitter
For high temperatures
For small spaces, high temperatures
1 2 3 4 5 6
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330
5
0
HMT335
Transmitter type
5
Cable length
2 m cable
L
5 m cable
M
10 m cable
N
No additional temperature probe
0
Parameters
RH+T
A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
B
Display
No display
0
Graphic display with keypad
1
Power supply
10...35 VDC , 24 VAC
(HMT300PWS)
0
Galvanic isolation for outputs 10...35 VDC , 24 VAC
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
+ Serial interface RS232 or optional communication module
Analog output signals
No 3rd analog output
for Ch1 , Ch2 and Ch3
RH
(0... 100%RH)
RH=relative humidity
T
(range: see below)
T=temperature
Td (-20...100°C)
(-4...+212 °F)
Td=dewpoint
Tdf (-20...100°C)
(-4...+212 °F)
Tdf = dewpoint/ frost point temperature
a=absolute humidity
a (0...600g/m3)
(0...262 gr/ft3)
Tw (0...100°C)
(+32...+212°F)
Tw=wet bulb temperature
x=mixing ratio
x (0...500g/kg d.a)
(0...3500gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
h=enthalpy
ppm (0…5000)
(0…5000)
ppm=parts per million
pw=water vapor pressure
pw (0…1000 hPa)
(0…14.5psi)
pws (0…1000 hPa)
(0…14.5psi)
pws=saturation water vapor pressure
dT (-10...+50 °C)
(14...+122 °F)
dT=(temperature-dewpoint temperature)
SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________
Define scale
Ch1:_______________ Ch2:________________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A, if not needed
Analog output range
No temperature output
(-40...+356°F)
for temperature
-40...+180°C
Note: Choose Option A,
Other:
Specify range:____________________
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A 1 PRICE
$1,640
1
2
$160
$370
3
4
$360
5
$320
6
$80
$200
$210
$60
7
1
2
3
4
5
B
C
D
E
F
G
H
J
K
L
M
N
X
B
C
D
E
F
G
H
J
K
L
M
N
X
A
B
C
D
E
F
G
H
J
K
L
M
N
X
8
9
10
11
A
E
X
13
14
15
16
17
18
19
20
21
22
23
Output units
Metric
Non-metric
Option for module slot 1
No module
Relay output
(Relay-1)
RS-485 serial interface (galvanically isolated)
(RS485-1)
Not with universal AC power
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logger module
Option for module slot 2
No module
Relay output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
Data logger module
Not possible if the data logger module has already been chosen in item 11
Cable bushings
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Note: The Universal AC
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
power not connected
8 pole connector with 5 m cable
(212142)
through 8 pole connector.
8 pole connector supplied with screw terminals
(212416)
Transmitter installation
Standard wall mounting
(214829)
Adapter plate (for replacing the HMP230's)
(215108)
Pole installation kit
DIN rail kit
(215094)
Humidity sensor type
General purpose
HUMICAP180
Chemical purge
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180R
Chemical purge
HUMICAP180RC
Sensor protection in probe PPS plastic grid & stainless steel netting (recommended choice)
(DRW010281SP)
PPS plastic grid
(DRW010276SP)
Sintered stainless steel filter
(HM47280SP)
Stainless steel grid
(HM47453SP)
Installation kit
No kit
for probe
Mounting flange
(210696)
Operating manual
No manual
(M210566EN)
language
English
No
PC Accessories
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable
(215005)
(219685)
Service cable for PC, USB with software driver
MI70LINK software for Windows® with USB service cable
(219916)
Calibration
ISO9001 compliant calibration with NIST traceable certificate
For future use
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A 1
1
2
0
1
2
4
5
6
12
Output units
13
Option for module slot 1
$180
$160
$260
$320
$350
14
0
1
3
6
Option for module slot 2
$180
$160
$350
15
A
B
C
D
Cable bushings
Note: The Universal AC
power not connected
$60
$60
through 8 pole connector.
16
0
1
2
4
Transmitter installation
$90
$100
$90
1
4
A
C
$60
17
Humidity sensor type
$60
A
B
C
D
A
G
$60
18
Sensor protection
19
Installation kit
for probe
A
B
A
B
C
D
E
$40
$60
$90
$90
20
21
A
Operating manual
language
PC Accessories
1
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
HMT330 5 L 0 A 0 0 1 B C A E 2 0 0 A 0 A A A B A A
$160
$370
$360
$320
$80
$200
$210
$60
1
2
3
4
5
B
C
D
E
F
G
H
J
K
L
M
N
X
B
C
D
E
F
G
H
J
K
L
M
N
X
22
23
Calibration
For future use
Metric
Non-metric
No module
Relay output
(Relay-1)
RS-485 serial interface (galvanically isolated)
(RS485-1)
LAN (Ethernet) interface + 2 m cable (RJ45)
Not with universal AC power
WLAN (Wireless Ethernet) interface + antenna
Data logger
No module
Relay output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
Data logger module
Not possible if the data logger module has already been chosen in item 11
Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
(212142)
8 pole connector with 5 m cable
(212416)
8 pole connector supplied with screw terminals
Standard wall mounting
(214829)
Adapter plate (for replacing the HMP230's)
(215108)
Pole installation kit
(215109)
Pole installation kit with rain shield
DIN rail kit
(215094)
General purpose
HUMICAP180
Chemical purge default
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180R
Chemical purge
HUMICAP180RC
PPS plastic grid & stainless steel netting
(DRW010281SP)
PPS plastic grid
(DRW010276SP)
Sintered stainless steel filter
(HM47280SP)
Stainless steel grid
(HM47453SP)
No kit
Cable gland AGRO
(HMP247CG)
Duct installation kit
(210697)
Swagelok NPT 1/2"
(SWG12NPT12)
Swagelok ISO 3/8"
(SWG12ISO38)
Swagelok ISO 1/2"
(SWG12ISO12)
No manual
(M210566EN)
English
No
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable
(215005)
(219685)
Service cable for PC, USB with software driver
MI70LINK software for Windows® with USB service cable
(219916)
ISO9001 compliant calibration with NIST traceable certificate
1
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
A
B
C
D
E
F
G
H
J
K
L
M
N
X
A
E
X
1
2
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
A
B
C
D
$60
$60
0
1
2
3
4
$90
$100
$110
$90
1
4
A
C
$60
$60
A
B
C
D
A
D
C
K
L
Y
$60
$80
$60
$60
$60
A
B
A
B
C
D
E
$40
$60
$90
$90
A
1
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
HMT330 7 S 0 A 0 0 1 B C A E 2 0 0 A 0 A A A B A A
164
PRICE
$1,640
if no T output is desired
if no T output is desired
12
1 2 3 4 5 6
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330
7
0
HMT337
Transmitter type
7
S
Cable length
2 m cable
T
5 m cable
U
10 m cable
Additional temperature
No probe
0
probe
Parameters
RH+T
A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
B
Display
No display
0
Graphic display with keypad
1
Power supply
10...35 VDC, 24 VAC
(HMT300PWS)
0
Galvanic isolation for outputs 10...35 VDC , 24 VAC
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
+ Serial interface RS232 or optional communication module
Analog output signals
No 3rd analog output
for Ch1 , Ch2 and Ch3
RH
(0... 100%RH)
RH=relative humidity
T
(range : see below)
T=temperature
Td (-20...100°C)
(-4...+212 °F)
Td=dewpoint
Tdf (-20...100°C)
(-4...+212 °F)
Tdf = dewpoint/ frost point temperature
a=absolute humidity
a (0...600g/m3)
(0...262 gr/ft3)
Tw (0...100°C)
(+32...+212°F)
Tw=wet bulb temperature
x=mixing ratio
x (0...500g/kg d.a)
(0...3500gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
h=enthalpy
ppm (0…5000)
(0…5000)
ppm=parts per million
pw=water vapor pressure
pw (0…1000 hPa)
(0…14.5psi)
pws (0…1000 hPa)
(0…14.5psi)
pws=saturation water vapor pressure
dT (-10...+50 °C)
(14...+122 °F)
dT=(temperature-dewpoint temperature)
SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________
Define scale
Ch1:_______________ Ch2:________________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A, if not needed
Analog output range
No temperature output
(-40...+356°F)
for temperature
-40...+180°C
Note: Choose Option A,
Other:
Specify range:____________________
1
165
1
2
3
4
5
6
7
8
9
10
11
HMT337 Humidity and Temperature Transmitter with warmed probe
HMT338 Humidity and Temperature Transmitter
For high humidities
For pressurized pipelines
1 2 3 4 5 6
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330
7
HMT337
Transmitter type
7
S
Cable length
2 m cable
T
dew point probe
5 m cable
U
10 m cable
Additional temperature
No probe
0
probe
2 m cable
1
5 m cable
2
10 m cable
3
Parameters
Td+Tdf+x
(dew point probe only)
C
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
D
Display
No display
0
Graphic display with keypad
1
Power supply
10...35 VDC , 24 VAC
(HMT300PWS)
0
Galvanic isolation for outputs 10...35 VDC , 24 VAC
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
+ Serial interface RS232 or optional communication module
Analog output signals
No 3rd analog output
for Ch1 , Ch2 and Ch3
RH
(0... 100%RH)
RH=relative humidity
T
(range: see below)
T=temperature
Td (-20...100°C)
(-4...+212 °F)
Td=dewpoint
Tdf (-20...100°C)
(-4...+212 °F)
Tdf = dewpoint/ frost point temperature
a=absolute humidity
a (0...600g/m3)
(0...262 gr/ft3)
Tw (0...100°C)
(+32...+212°F)
Tw=wet bulb temperature
x=mixing ratio
x (0...500g/kg d.a)
(0...3500gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
h=enthalpy
ppm (0…5000)
(0…5000)
ppm=parts per million
pw=water vapor pressure
pw (0…1000 hPa)
(0…14.5psi)
pws (0…1000 hPa)
(0…14.5psi)
pws=saturation water vapor pressure
dT (-10...+50 °C)
(14...+122 °F)
dT=(temperature-dewpoint temperature)
SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________
Define scale
Ch1:_______________ Ch2:________________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A, if not needed
Analog output range
No temperature output
(-40...+356°F)
for temperature
-40...+180°C
Note: Choose Option A,
Other:
Specify range:____________________
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A 1
PRICE
$2,480
1
2
$160
$370
$160
$180
$220
3
4
5
$320
6
$80
$200
$210
$60
7
1
2
3
4
5
B
C
D
E
F
G
H
J
K
L
M
N
X
B
C
D
E
F
G
H
J
K
L
M
N
X
A
B
C
D
E
F
G
H
J
K
L
M
N
X
8
9
10
11
A
E
X
Output units
13
Option for module slot 1
14
15
16
17
Option for module slot 2
Cable bushings
Transmitter installation
Humidity sensor type
18
Sensor protection
19
Installation kit
for probe
20
21
22
23
Operating manual
language
PC Accessories
Calibration
For future use
Metric
1
Non-metric
2
No module
0
Relay output
(Relay-1)
1
RS-485 serial interface (galvanically isolated)
(RS485-1)
2
LAN (Ethernet) interface + 2 m cable (RJ45)
4
Not with universal AC power
WLAN (Wireless Ethernet) interface + antenna
5
Data logger module
6
No module
0
Relay output
(Relay-1)
1
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
3
Data logger module
Not possible if the data logger module has already been chosen in item 11
6
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
8-pole connector with 5m cable (not possible with Universal AC power option)
(212142)
(212416)
8-pole counter connector equipped with screw terminals (not possible with Universal AC power option)
Standard wall mounting
(214829)
Adapter plate (for replacing the HMP230's)
(215108)
Pole installation kit
(215109)
Pole installation kit with rain shield
DIN rail kit
(215094)
Composite sensor
HUMICAP180C
Composite sensor with chemical purge
HUMICAP180C
Compsite sensor
HUMICAP180RC
HUMICAP180RC
Compsite sensor with chemical purge
HUMICAP180RC
Composite sensor for fuel cell applications
PPS plastic grid & stainless steel netting
(DRW010281SP)
Sintered stainless steel filter
(HM47280SP)
Stainless steel grid
(HM47453SP)
(214848)
Membrane SST filter for fuel cell applications
No kit
Duct installation kit (RH)
(210697)
Swagelok NPT 1/2" (RH)
(SWG12NPT12)
Swagelok ISO 3/8" (RH)
(SWG12ISO38)
Duct installation kit (RH + T probes)
(210697 & 215003)
Swagelok NPT 1/2" + Swagelok NPT 1/8" (RH + T)
(SWG6NPT18 & SWG12NPT12)
Swagelok ISO 3/8" + Swagelok ISO 3/8" (RH + T)
(SWG6ISO18 & SWG12ISO18)
(SWG12ISO12)
Swagelok ISO 1/2"
No manual
(M210566EN)
English
No
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable
(215005)
(219685)
Service cable for PC, USB with software driver
(219916)
MI70LINK software for Windows® with USB service cable
ISO9001 compliant calibration with NIST traceable certificate
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
12
Output units
13
Option for module slot 1
$180
$160
$260
$320
$350
14
Option for module slot 2
$180
$160
$350
A
B
C
D
15
Cable bushings
16
Transmitter installation
$60
$60
0
1
2
3
4
$90
$100
$110
$90
5
6
D
E
F
A
C
D
F
A
C
K
L
P
Q
R
Y
$80
$60
$60
$160
$120
$120
$60
17
A
B
C
D
E
$40
$60
$90
$90
A
1
TOTAL
QTY
TOTAL VALUE
Humidity sensor type
18
Sensor protection
19
Installation kit
for probe
20
Operating manual
language
PC Accessories
21
22
23
A
B
Example of order code with typical settings:
HMT330 7 S 1 D 0 0 1 B C A E 2 0 0 A 0 D A A B A A
166
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A 1
PRICE
$1,980
$160
$370
$120
$260
$460
$360
$320
$80
$200
$210
$60
B
C
D
E
F
G
H
J
K
L
M
N
X
B
C
D
E
F
G
H
J
K
L
M
N
X
A
B
C
D
E
F
G
H
J
K
L
M
N
X
A
E
X
if no T output is desired
if no T output is desired
12
1 2 3 4 5 6 7
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330
8
0
Transmitter type
HMT338
8
Cable length
2 m cable for 232 mm probe
V
5 m cable for 232 mm probe
W
10 m cable for 232 mm probe
X
2 m cable for 454 mm probe
1
5 m cable for 454 mm probe
2
10 m cable for 454 mm probe
3
No additional temperature probe
0
Parameters
RH+T
A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
B
Display
No display
0
Graphic display with keypad
1
Power supply
10...35 VDC , 24 VAC
0
(HMT300PWS)
Galvanic isolation for outputs 10...35 VDC , 24 VAC
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog Output Signal
4... 20 mA
1
for Ch1&Ch2(&Ch3)
0... 20 mA
2
0... 1 V
3
0... 5 V
4
0... 10 V
5
+ Serial interface RS232 or optional communication module
Analog output signals
No 3rd analog output
for Ch1 , Ch2 and Ch3
RH
(0... 100%RH)
RH=relative humidity
T
(range: see below)
T=temperature
Td (-20...100°C)
(-4...+212 °F)
Td=dewpoint
Tdf (-20...100°C)
(-4...+212 °F)
Tdf = dewpoint/ frost point temperature
a (0...600g/m3)
(0...262 gr/ft3)
a=absolute humidity
Tw (0...100°C)
(+32...+212°F)
Tw=wet bulb temperature
x (0...500g/kg d.a)
(0...3500gr/lb)
x=mixing ratio
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
h=enthalpy
ppm (0…5000)
(0…5000)
ppm=parts per million
pw (0…1000 hPa)
(0…14.5psi)
pw=water vapor pressure
pws (0…1000 hPa)
(0…14.5psi)
pws=saturation water vapor pressure
dT (-10...+50 °C)
(14...+122 °F)
dT=(temperature-dewpoint temperature)
SPECIAL
Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________
Define scale
Ch1:_______________ Ch2:________________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A, if not needed
Analog output range
No temperature output
for temperature
-40...+180°C
(-40...+356°F)
Note: Choose Option A,
Other:
Specify range:____________________
Calibration
For future use
Metric
1
Non-metric
2
No module
0
Relay output
(Relay-1)
1
RS-485 serial interface (galvanically isolated)
(RS485-1)
2
LAN (Ethernet) interface + 2 m cable (RJ45)
4
Not with universal AC power
WLAN (Wireless Ethernet) interface + antenna
5
Data logger module
6
No module
0
Relay output
(Relay-1)
1
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
3
Data logger module
Not possible if the data logger module has already been chosen in item 11
6
Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
8-pole connector with 5m cable (not possible with Universal AC power option)
(212142)
(212416)
8-pole counter connector equipped with screw terminals (not possible with Universal AC power option)
Standard wall mounting
(214829)
Adapter plate (for replacing the HMP230's)
(215108)
Pole installation kit
DIN rail kit
(215094)
General purpose
HUMICAP180
Chemical purge
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180R
Chemical purge
HUMICAP180RC
PPS plastic grid & stainless steel netting
(DRW010281SP)
PPS plastic grid
(DRW010276SP)
Sintered stainless steel filter
(HM47280SP)
Stainless steel grid
(HM47453SP)
Ball valve set (ISO 1/2")
(DRW212076 + BALLVALVE-1)
Pressure fitting NPT 1/2"
(212810SP)
Pressure fitting ISO 1/2"
(DRW212076SP)
No manual
English
(M210566EN)
No PC Accessories
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable
(215005)
(219685)
Service cable for PC, USB with software driver
MI70LINK software for Windows® with USB service cable
(219916)
ISO9001 compliant calibration with NIST traceable certificate
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
$180
$160
$260
$320
$350
$180
$160
$350
A
B
C
D
$60
$60
0
1
2
4
$90
$100
$90
1
4
A
C
$60
$60
A
B
C
D
M
N
V
$80
A
B
A
B
C
D
E
A
1
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
HMT330 8 V 0 A 0 0 1 B C A E 2 0 0 A 0 A C N B A A
Accessories: Description
Order Code
Sample cell (no fittings)
DMT242SC
Sample cell (with Swagelok connectors) DMT242SC2
$40
$60
$90
$90
1
PRICE
$80
$100
1
167
Vaisala Meteorological Installation Kit for HMT330 Transmitters
1
2
3
4
5
Vaisala Meteorological Installation Kit
Support bar & shield for warmed Td probe
1 2 3 4 5
HMT330MIK
No support bar & shield for warmed Td probe
Support bar, transmitter mounting plate & shield for warmed Td probe
No support bar or radiation shield
Support bar and radiation shield for
Support bar with DTR502 shield for T probe
additional T probe or for
Support bar with DTR13 shield for T probe
non-warmed RH or Td probe
Support bar with DTR502 shield for non-warmed RH or Td probe
Support bar with DTR13 shield for non-warmed RH or Td probe
No mounting plate
Support bar mounting plate
Pole mounting plate for support bar/bars
Additional transmitter mounting plate
No additional transmitter mounting plate
Transmitter mounting plate for support bar assembly
Transmitter mounting plate for pole assembly
Static Pressure Head
No Static Pressure Head
Static Pressure Head SPH10
Selections in bold are included in the prices of the basic versions.
Selections in italic have an additional cost
Shaded sections indicate typical selections.
HMP155 Humidity and Temperature Probe
PRICE
0
1
$580
A
B
C
D
E
$580
$920
$580
$920
0
1
1
2
3
4
$120
A
B
C
0
1
TOTAL
QTY
TOTAL VALUE
$110
$110
5
6
$270
7
8
Example of order code with typical settings:
HMT330MIK
1 B 1 A 1
9
10
11
12
13
14
15
with voltage or RS485 output for temperature
Vaisala HUMICAP® Humidity and Temperature Probe
2 x voltage output (RS485 for service use)
Probe type
RS485 serial output
Signal output selection
RS485 serial output (only for probe type E)
0…1 V output
0…5 V output
0…10 V output
Analog output signal for CH1
None (RS485 output used)
T (-40…+60°C)
T (-40…+140°F)
Choose option A, if No T output
is desired, or output is RS485
T (-80…+60°C)
T (-112…+140°F)
None (RS485 output used)
Analog output signal for CH2
(0…100%RH)
RH
Choose option A if output is RS485
Td (-60…+60°C)
T (-76…+140°F)
Tdf (-60…+60°C)
T (-76…+140°F)
Tw (0…+60°C)
T (+32…+140°F)
x (0…200g/kg d.a)
(0…1400 gr/lb)
Units
Metric
Non Metric
Humidity Sensor Type
General purpose
HUMICAP180R
Composite sensor
HUMICAP180RC
Gereral purpose
HUMICAP180
Composite sensor
HUMICAP180C
Heating options
None
See(*) Note below
Warmed probe (only with composite sensor)
Warmed probe with Xheat (only with composite sensor)
Chemical purge
None
Periodical (only with composite sensor)
Start-up (only with composite sensor)
Both periodical & start-up (only with composite sensor)
Sensor protection
Sintered Teflon filter
Probe cable length
No cable (no counter connector)
3.5 meter (with 8 pin M12 female connector)
10 meter (with 8 pin M12 female connector)
30 meter (with 8 pin M12 female connector)
Additional Temperature probe
None
Additional T-probe with 2 m cable
Calibration
At room temperature
PC-Accessories
None
PC connection cable (USB)
MI70 connection cable
PC connection cable (USB) & MI70 connection cable
Installation accessories
None
Installation kit to Stevenson screen
Additional T-probe installation part to DTR502
Additional T-probe installation part to DTR13
(For production use only)
(*) NOTE: If warmed probe is chosen and additional temperature sensor is not used
output signal for Ch1 must be 'None' and for Ch2 only Td, Tdf or x output can be selected.
168
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
1
A
A
E
PRICE
$640
1
2
3
4
A
G
J
A
B
C
D
E
F
1
2
1
2
3
4
RH&T outputs only with Additional Temperature probe
RH&T outputs only with Additional Temperature probe
$60
$60
A
B
C
$280
$280
0
1
2
3
A
0
1
2
3
$30
$50
$80
A
B
$160
1
A
B
C
D
Item: 221040
Item: 221801
Item: 222303
$90
$60
$150
0
1
2
3
Item: 221321
Item: 221072
Item: 221069
$95
$60
$80
A
Example of order code with typical settings:
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Acessories and Spare Parts:
HMP155
HMP155 A 2 G B 2 1 A 0 A 1 A 1 A 0 A
Description:
Connection cable 3.5 m - 8-pin M12
Connection cable 10 m - 8-pin M12
Connection cable 30 m - 8-pin M12
Sintered Teflon filter + O-ring
Protection Set for Calibration Buttons
Solar shield for humidity probe
Solar shield for additional temperature probe
Order Code:
220496
220497
220498
219452SP
221318
DTR503A
DTR502B
PRICE
$30
$50
$80
$50
$15
$310
$310
169
HMT361 Humidity and Temperature Transmitter
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
with resistive 4-wire output for temperature
Vaisala HUMICAP® Humidity and Temperature Probe
Voltage output for RH (RS485 for service use), 4-wire Pt100 output for Temperature
Probe type
Signal output selection
0…1 V output
0…5 V output
0…10 V output
Analog output signal for CH1
None (4-wire PT100 output used)
(0…100%RH)
Analog output signal for CH2
RH
Units
Metric
Non Metric
HUMICAP180R
Humidity Sensor Type
General purpose
HUMICAP180
Gereral purpose
Heating options
None
Chemical purge
None
Sensor protection
Sintered Teflon filter
Probe cable length
No cable (no counter connector)
3.5 meter (with 8 pin M12 female connector)
10 meter (with 8 pin M12 female connector)
30 meter (with 8 pin M12 female connector)
Additional Temperature probe
None
Calibration
At room temperature
PC-Accessories
None
PC connection cable (USB)
Item: 221040
MI70 connection cable
Item: 221801
PC connection cable (USB) & MI70 connection cable
Item: 222303
Installation accessories
None
Installation kit to Stevenson screen
Item: 221321
(For production use only)
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Acessories and Spare Parts:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A B
A 0 A
A 1
A
HMP155 D
D
2
3
4
A
B
1
2
1
3
A
0
A
0
1
2
3
A
1
A
B
C
D
0
1
A
For wall mounting
1
PRICE
$600
1
2
3
4
$30
$50
$80
$100
$60
$160
$95
5
6
7
Example of order code with typical settings:
HMP155 D 2 A B 2 1 A 0 A 1 A 1 A 0 A
8
Description:
Connection cable 3.5 m - 8-pin M12
Connection cable 10 m - 8-pin M12
Connection cable 30 m - 8-pin M12
Sintered Teflon filter + O-ring
Protection Set for Calibration Buttons
Solar shield for humidity probe
Order Code:
220496
220497
220498
219452SP
221318
DTR503A
PRICE
$30
$50
$80
$50
$15
$310
9
10
11
12
13
14
15
16
2
3
4
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360 1
Transmitter type
HMT361
1
RH+T
A
Parameters
RH+T+Td+a+Tw+x
D
Display
No display
1
Display on transmitter cover
2
Signal output
2 analog output channels (Ch1 + Ch24... 20 mA 2
Parameter and scaling for
No analog output
analog output (Ch1 & Ch2)
RH (0... 100%RH)
T (choose range in next section)
Td (-40…60°C)
(-40... 140°F)
a (0... 160g/m3)
(0...70gr/ft3)
Tw (0…60°C)
(+32...+140°F)
x (0...160g/kg d.a) (0…1120gr/lb)
Special:
Define quantity for:
CH1:____________CH2:________________
Define scale for:
CH1:____________CH2:________________
NOTE:
Transmitter unit
HMP155 Humidity and Temperature Probe
5
6
7
8
9
10
11
12
13
14
15
16
A
PRICE
$2,120
$2,660
$120
B
C
D
E
F
G
X
A
B
C
D
E
F
G
X
- Td, a, Tw and x are only avalable with parameter selection D
Ch1
- If only one analog output has been chosen, choose A for Ch2
Ch2
Analog output range
-40...+60°C
(-40...+140°F)
A
for temperature
-20...+60°C
(-4...+140°F)
B
- If no temperature output is desired, choo0...+60°C
(+32...+140°F)
C
Special
X
Output units
Metric
1
Non-metric
2
Interface cable connection
Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
A
Conduit fitting NPT1/2"
(for wire conduits)
B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm
C
Ex certification and issuer
ATEX 100a 94/9/EC (PTB)
2
Factory Mutual (USA)
4
CSA (Canada)
5
TIIS (Japan)
7
User's guide
No manual
A
English
B
Probe and cable length
HMP361
max +60°C
A
Sensor type
HUMICAP 180
1
HUMICAP 180L2
2
HUMICAP 180R
5
Reserved for future option
A
Sensor protection
PPS plastic grid & stainless steel netting (recommended choi DRW0101281SP
1
PPS plastic grid
DRW0101276SP
2
Sintered stainless steel filter
HM47280SP
3
Stainless steel grid filter
HM47453SP
4
Reserved for future option
0
TOTAL
Selections in bold are included in the prices of the basic versions.
QTY
Selections in italic are available at an extra price.
TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
HMT360 1 A 2 2 B C A 2 A 4 B A 5 A 1 0
RH = Relative Humidity a = Absolute Humidity g/m3
T = Temperature
x = Mixing Ratio g/Kg
Td = Dewpoint TemperaTw = Wet Bulb Temperature
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description
Stahl Zener Barrier (Stahl # 9001/51-280-091-141)
(active barrier that requires active input)
Vyniker enclosure
(enclosure holds 2 barriers)
170
Order Code:
210664
210665
PRICE
$190/channel
$90 each
171
HMT363 Humidity and Temperature Transmitter
HMT364 Humidity and Temperature Transmitter
For general use
For high pressurized processes
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Transmitter unit
1
2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
16
A
PRICE
$2,160
$2,710
3
$120
4
B
C
H
J
K
L
X
A
B
C
H
J
K
L
X
- Td, a, Tw and x are only avalable with parameter selection D
Ch1
- If only one analog output has been chosen, choose A for Ch2
Ch2
Analog output range
-20...+80°C
(-4...+176°F)
D
for temperature
-20...+120°C
(-4...+248°F)
E
-40...+80°C
(-40...+176°F)
F
- If no temperature output is desired, choo-40...+120°C
(-40...+248°F)
G
0...+100°C
(+32...+ 212°F)
H
Special
X
Output units
Metric
1
Non-metric
2
Interface cable connection
Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
A
Conduit fitting NPT1/2"
(for wire conduits)
B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm
C
Ex certification and issuer
ATEX 100a 94/9/EC (PTB)
2
Factory Mutual (USA)
4
CSA (Canada)
5
TIIS (Japan)
7
User's guide
No manual
A
English
B
Probe and cable length
2 m cable
max 80°C
1
5 m cable
max 80°C
2
10 m cable
max 80°C
3
2 m cable
max 120°C
B
5 m cable
max 120°C
C
10 m cable
max 120°C
D
Sensor type
HUMICAP 180
1
HUMICAP 180L2
2
HUMICAP 180R
5
Reserved for future option
A
Sensor protection
PPS plastic grid & stainless steel netting (recommended choi DRW0101281SP
1
PPS plastic grid
DRW0101276SP
2
Sintered stainless steel filter
HM47280SP
3
Stainless steel grid filter
HM47453SP
4
Probe installation accessories
None
0
Duct installation kit
B
TOTAL
Selections in bold are included in the prices of the basic versions.
QTY
Selections in italic are available at an extra price.
TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
HMT360
3 A 2 2 B C D 2 A 4 B B 5 A 1 B
RH = Relative Humidity a = Absolute Humidity g/m3
T = Temperature
x = Mixing Ratio g/Kg
Td = Dewpoint TemperaTw = Wet Bulb Temperature
5
6
7
8
9
10
$150
$300
$220
$360
$540
$80
Accessories and Spare Parts : Description
Stahl Zener Barrier (Stahl # 9001/51-280-091-141)
(active barrier that requires active input)
Vyniker enclosure
(enclosure holds 2 barriers)
Order Code:
210664
210665
11
12
13
3
4
5
6
7
8
9
10
11
12
13
14
15
16
PRICE
A
$3,270
$3,810
$120
B
C
H
J
K
L
X
A
B
C
H
J
K
L
X
- Td, a, Tw and x are only avalable with parameter selection D
Ch1
- If only one analog output has been chosen, choose A for Ch2
Ch2
(-4...+176°F)
Analog output range
-20...+80°C
for temperature
(-4...+248°F)
-20...+120°C
(-40...+176°F)
-40...+80°C
- If no temperature output is desired, choo-40...+120°C
(-40...+248°F)
(+32...+ 212°F)
0...+100°C
(-4...+356°F)
-20...+180°C
(-40...+356°F)
-40...+180 °C
(+32...+356°F)
0...+180°C
Special
Output units
Metric
Non-metric
Interface cable connection
Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
(for wire conduits)
Conduit fitting NPT1/2"
Cable gland M20x1.5 for cable diameters 10 ... 15 mm
Ex certification and issuer
ATEX 100a 94/9/EC (PTB)
Factory Mutual (USA)
CSA (Canada)
TIIS (Japan)
User's guide
No manual
English
Probe and cable length
2 m cable
5 m cable
10 m cable
Sensor type
HUMICAP 180
HUMICAP 180L2
HUMICAP 180R
D
E
F
G
H
J
K
L
X
1
2
A
B
C
2
4
5
7
A
B
E
F
G
$160
$370
1
2
5
A
14
15
Sensor protection
16
Probe installation accessories
PPS plastic grid & stainless steel netting (recommended choic DRW0101281SP
DRW0101276SP
PPS plastic grid
HM47280SP
Sintered stainless steel filter
HM47453SP
Stainless steel grid filter
None
Fitting body M22x1.5 male
Fitting body NPT 1/2" male
1
2
3
4
0
K
G
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings:
RH = Relative Humidity a = Absolute Humidity g/m3
HMT360
4 A 2 2 B C D 2 A 4 B E 5 A 3 G
T = Temperature
x = Mixing Ratio g/Kg
Td = Dewpoint TemperaTw = Wet Bulb Temperature
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
172
1
2
2
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360 4
Transmitter type
HMT364
4
RH+T
A
Parameters
RH+T+Td+a+Tw+x
D
Display
No display
1
Display on transmitter cover
2
Signal Output
2 analog output channels (Ch1 + Ch24... 20 mA 2
Parameter and scaling for
No analog output
analog output (Ch1 & Ch2)
RH (0... 100%RH)
T (choose range in next section)
(-40...212°F)
Td (-40...100°C)
(0...218.5gr/ft3)
a (0...500g/m3)
(+32...+212°F)
Tw (0...100°C)
x (0...500g/kg d.a) (0...3500gr/lb)
Special:
Define quantity for:
CH1:____________CH2:________________
Define scale for:
CH1:____________CH2:________________
NOTE:
Transmitter unit
1
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360 3
Transmitter type
HMT363
3
RH+T
A
Parameters
RH+T+Td+a+Tw+x
D
Display
No display
1
Display on transmitter cover
2
Signal Output
2 analog output channels (Ch1 + Ch2) 4... 20 mA 2
Parameter and scaling for
No analog output
analog output (Ch1 & Ch2)
RH (0... 100%RH)
T (choose range in next section)
Td (-40...100°C)
(-40...212°F)
a (0...500g/m3)
(0...218.5gr/ft3)
Tw (0...100°C)
(+32...+212°F)
x (0...500g/kg d.a) (0...3500gr/lb)
Special:
Define quantity for:
CH1:____________CH2:________________
Define scale for:
CH1:____________CH2:________________
NOTE:
PRICE
$190/channel
$90 each
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description
Stahl Zener Barrier (Stahl # 9001/51-280-091-141)
(active barrier that requires active input)
Vyniker enclosure
(enclosure holds 2 barriers)
Order Code:
210664
210665
PRICE
$190/channel
$90 each
173
HMT365 Humidity and Temperature Transmitter
HMT367 Humidity and Temperature Transmitter
For high temperatures
For high humidities
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Transmitter unit
1
2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
16
PRICE
A
$2,840
$3,370
$120
B
C
H
J
K
L
X
Transmitter type
Parameters
3
Display
4
Signal Output
Parameter and scaling for
analog output (Ch1 & Ch2)
A
B
C
H
J
K
L
X
- Td, a, Tw and x are only avalable with parameter selection D
Ch1
- If only one analog output has been chosen, choose A for Ch2
Ch2
Analog output range
-20...+80°C
(-4...+176°F)
for temperature
-20...+120°C
(-4...+248°F)
-40...+80°C
(-40...+176°F)
- If no temperature output is desired, choo-40...+120°C
(-40...+248°F)
0...+100°C
(+32...+ 212°F)
-20...+180°C
(-4...+356°F)
-40...+180 °C
(-40...+356°F)
0...+180°C
(+32...+356°F)
Special
Output units
Metric
Non-metric
Interface cable connection
Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
Conduit fitting NPT1/2"
(for wire conduits)
Cable gland M20x1.5 for cable diameters 10 ... 15 mm
Ex certification and issuer
ATEX 100a 94/9/EC (PTB)
Factory Mutual (USA)
CSA (Canada)
TIIS (Japan)
User's guide
No manual
English
Probe and cable length
2 m cable
5 m cable
10 m cable
Sensor type
HUMICAP 180
HUMICAP 180L2
HUMICAP 180R
5
6
7
D
E
F
G
H
J
K
L
X
8
9
1
2
A
B
C
10
2
4
5
7
11
12
A
B
H
J
K
13
$160
$370
1
2
5
14
15
A
Sensor protection
Probe installation accessories
PPS plastic grid & stainless steel netting (recommended choi DRW0101281SP
PPS plastic grid
DRW0101276SP
Sintered stainless steel filter
HM47280SP
Stainless steel grid filter
HM47453SP
None
Mounting flange
1
2
3
4
0
D
TOTAL
QTY
TOTAL VALUE
16
$60
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings:
HMT360
5 A 2 2 B C D 2 A 4 B H 5 A 1 D
RH = Relative Humidity a = Absolute Humidity g/m3
T = Temperature
x = Mixing Ratio g/Kg
Td = Dewpoint TemperaTw = Wet Bulb Temperature
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description
Stahl Zener Barrier (Stahl # 9001/51-280-091-141)
(active barrier that requires active input)
Vyniker enclosure
(enclosure holds 2 barriers)
174
Vaisala HUMICAP® Humidity and Temperature Transmitter
1
2
Order Code:
210664
210665
PRICE
$190/channel
$90 each
Transmitter unit
1
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360 5
Transmitter type
HMT365
5
RH+T
A
Parameters
RH+T+Td+a+Tw+x
D
Display
No display
1
Display on transmitter cover
2
Signal Output
2 analog output channels (Ch1 + Ch24... 20 mA 2
Parameter and scaling for
No analog output
analog output (Ch1 & Ch2)
RH (0... 100%RH)
T (choose range in next section)
Td (-40...100°C)
(-40...212°F)
a (0...500g/m3)
(0...218.5gr/ft3)
Tw (0...100°C)
(+32...+212°F)
x (0...500g/kg d.a) (0...3500gr/lb)
Special:
Define quantity for:
CH1:____________CH2:________________
Define scale for:
CH1:____________CH2:________________
NOTE:
Special:
Define quantity for:
Define scale for:
2
3
4
5
6
7
8
9
HMT360 7
HMT367
7
RH+T
A
RH+T+Td+a+Tw+x
D
No display
1
Display on transmitter cover
2
2 analog output channels (Ch1 + Ch24... 20 mA 2
No analog output
RH (0... 100%RH)
T (choose range in next section)
Td (-40...100°C)
(-40...212°F)
a (0...500g/m3)
(0...218.5gr/ft3)
Tw (0...100°C)
(+32...+212°F)
x (0...500g/kg d.a) (0...3500gr/lb)
CH1:____________CH2:________________
CH1:____________CH2:________________
10
11
12
13
14
15
16
A
PRICE
$2,840
$3,370
$120
B
C
H
J
K
L
X
A
B
C
H
J
K
L
X
NOTE:
- Td, a, Tw and x are only avalable with parameter selection D
Ch1
- If only one analog output has been chosen, choose A for Ch2
Ch2
Analog output range
-20...+80°C
(-4...+176°F)
D
for temperature
-20...+120°C
(-4...+248°F)
E
-40...+80°C
(-40...+176°F)
F
- If no temperature output is desired, choo-40...+120°C
(-40...+248°F)
G
0...+100°C
(+32...+ 212°F)
H
-20...+180°C
(-4...+356°F)
J
-40...+180 °C
(-40...+356°F)
K
0...+180°C
(+32...+356°F)
L
Special
X
Output units
Metric
1
Non-metric
2
Interface cable connection
Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
A
Conduit fitting NPT1/2"
(for wire conduits)
B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm
C
Ex certification and issuer
ATEX 100a 94/9/EC (PTB)
2
Factory Mutual (USA)
4
CSA (Canada)
5
TIIS (Japan)
7
User's guide
No manual
A
English
B
Probe and cable length
2 m cable
V
5 m cable
W
10 m cable
X
Sensor type
HUMICAP 180
1
HUMICAP 180L2
2
HUMICAP 180R
5
Reserved for future option
A
1
Sensor protection
PPS plastic grid & stainless steel netting (recommended choic DRW0101281SP
PPS plastic grid
DRW0101276SP
2
Sintered stainless steel filter
HM47280SP
3
Stainless steel grid filter
HM47453SP
4
Probe installation accessories
None
0
Duct installation kit
B
Cable Gland AGRO
J
Swagelok NPT 1/2"
L
Swagelok ISO 3/8"
M
TOTAL
Selections in bold are included in the prices of the basic versions.
QTY
Selections in italic are available at an extra price.
TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
RH = Relative Humidity a = Absolute Humidity g/m3
HMT360
7 A 2 2 B C D 2 A 4 B V 5 A 1 L
T = Temperature
x = Mixing Ratio g/Kg
Td = Dewpoint TemperaTw = Wet Bulb Temperature
$160
$370
$80
$60
$60
$60
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description
Stahl Zener Barrier (Stahl # 9001/51-280-091-141)
(active barrier that requires active input)
Vyniker enclosure
(enclosure holds 2 barriers)
Order Code:
210664
210665
PRICE
$190/channel
$90 each
175
HMT368F Moisture and Temperature Transmitter for Oil
HMT368 Humidity and Temperature Transmitter
For pressurized pipelines
3
4
5
6
7
8
9
10
11
12
13
14
15
16
3
4
5
6
7
8
9
10
11
12
13
14
15
1
16
A
PRICE
$3,020
$3,570
$120
B
C
H
J
K
L
X
A
B
C
H
J
K
L
X
Analog output range
for temperature
- If no temperature output is desired, choose A
Order Code:
210664
210665
8
Output units
9
Interface cable connection
10
Ex certification and issuer
$160
$370
$120
$260
$460
11
User's guide
12
Probe and cable length
13
14
15
16
3
Sensor type
-40...+60°C
-20...+60°C
0...+60°C
-20...+80°C
-20...+120°C
-40...+80°C
-40...+120°C
0...+100°C
-20...+180°C
-40...+180 °C
0...+180°C
Special
4
5
6
7
8
9
10
11
12
13
14
15
2
A
4
16
PRICE
$3,440
$120
2
C
M
X
Ch1
Ch2
(-40...+140°F)
(-4...+140°F)
(+32...+140°F)
(-4...+176°F)
(-4...+248°F)
(-40...+176°F)
(-40...+248°F)
(+32...+ 212°F)
(-4...+356°F)
(-40...+356°F)
(+32...+356°F)
Scale (in °C or F)
Metric
Non-metric
Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
(for wire conduits)
Conduit fitting NPT1/2"
Cable gland M20x1.5 for cable diameters 10 ... 15 mm
ATEX 100a 94/9/EC (PTB)
Factory Mutual (USA)
CSA (Canada)
TIIS (Japan)
None
English
German
French
Finnish
Swedish
Japanese
2m (6.6 ft)
226 mm probe
(9")
5 m (16.4 ft)
226 mm probe
(9")
10 m (32.8 ft)
226 mm probe
(9")
2m (6.6 ft)
448 mm probe
(18")
5 m (16.4 ft)
448 mm probe
(18")
10 m (32.8 ft)
448 mm probe
(18")
Special sensor for fluids
A
C
M
X
A
B
C
D
E
F
G
H
J
K
L
X
1
2
A
B
C
2
4
5
7
A
B
C
D
E
G
J
L
M
N
P
Q
R
$160
$360
$80
$240
$440
2
A
Sensor protection
Probe installation
accessories
Stainless steel grid filter
Ball valve set for installation into pipeline
Fitting Body NPT1/2
Fitting Body ISO1/2
HM47453SP
4
E
H
N
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
$80
$80
Example of order code with typical settings:
HMT360 8 F 2 2 M C D 2
Spare parts & Accessories
Stahl Zener Barrier
Vyniker enclosure (holds 2 barriers)
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
176
4
5
6
7
- Td, a, Tw and x are only avalable with parameter selection D
Ch1
- If only one analog output has been chosen, choose A for Ch2
Ch2
Analog output range
-20...+80°C
(-4...+176°F)
D
for temperature
-20...+120°C
(-4...+248°F)
E
-40...+80°C
(-40...+176°F)
F
(-40...+248°F)
G
- If no temperature output is desired, choo-40...+120°C
0...+100°C
(+32...+ 212°F)
H
-20...+180°C
(-4...+356°F)
J
-40...+180 °C
(-40...+356°F)
K
0...+180°C
(+32...+356°F)
L
Special
X
Output units
Metric
1
Non-metric
2
Interface cable connection
Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
A
Conduit fitting NPT1/2"
(for wire conduits)
B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm
C
Ex certification and issuer
ATEX 100a 94/9/EC (PTB)
2
Factory Mutual (USA)
4
CSA (Canada)
5
TIIS (Japan)
7
User's guide
No manual
A
English
B
Probe and cable length
2 m cable
226 mm probe, max 180°C
L
5 m cable
226 mm probe, max 180°C
M
10 m cable
226 mm probe, max 180°C
N
2 m cable
448 mm probe, max 180°C
P
5 m cable
448 mm probe, max 180°C
Q
10 m cable
448 mm probe, max 180°C
R
Sensor type
HUMICAP 180
1
HUMICAP 180L2
2
HUMICAP 180R
5
Reserved for future option
A
Sensor protection
PPS plastic grid & stainless steel netting (recommended choic DRW0101281SP
1
PPS plastic grid
DRW0101276SP
2
Sintered stainless steel filter
HM47280SP
3
Stainless steel grid filter
HM47453SP
4
Probe installation accessories
Ball valve set
E
Fitting Body NPT1/2
H
Fitting Body ISO1/2
N
TOTAL
Selections in bold are included in the prices of the basic versions.
QTY
Selections in italic are available at an extra price.
TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
RH = Relative Humidity a = Absolute Humidity g/m3
HMT360
8 A 2 2 B C D 2 A 4 B L 5 A 3 E
T = Temperature
x = Mixing Ratio g/Kg
Td = Dewpoint TemperaTw = Wet Bulb Temperature
Accessories and Spare Parts : Description
Stahl Zener Barrier (Stahl # 9001/51-280-091-141)
(active barrier that requires active input)
Vyniker enclosure
(enclosure holds 2 barriers)
1
2
3
2
Vaisala HUMICAP® Moisture and Temperature Transmitter for Oil
HMT360 8 F
HMT368
for pressurized pipelines
8
Transmitter type
aw+T
F
Parameters
Display
No display
1
Display on transmitter cover
2
Number of analog outputs
2 analog output channels (Ch1 + Ch2) 4... 20 mA
Parameter and scaling for
No analog output (Ch2)
analog output (Ch1 & Ch2)
Temperature
aw (0...1)
Define quantity for:
CH1:________________CH2:________________
Special:
Define scale for:
CH1:________________CH2:________________
Transmitter unit
2
Transmitter unit
1
2
Probe
1
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360 8
Transmitter type
HMT368
8
Parameters
RH+T
A
RH+T+Td+a+Tw+x
D
Display
no display
1
display on transmitter cover
2
Signal Output
2 analog output channels (Ch1 + Ch24... 20 mA 2
Parameter and scaling for
No analog output
analog output (Ch1 & Ch2)
RH (0... 100%RH)
Temperature (choose range in next section)
Td (-40...100°C)
(-40...212°F)
a (0...500g/m3)
(0...218.5gr/ft3)
Tw (0...100°C)
(+32...+212°F)
x (0...500g/kg d.a) (0...3500gr/lb)
Special:
Define quantity for:
CH1:____________CH2:________________
Define scale for:
CH1:____________CH2:________________
NOTE:
PRICE
$190/channel
Order Code:
210664
210665
A
4
B
M
2
A
4
E
PRICE
$190/channel
$90
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
$90 each
177
1
2
3
4
5
6
HMT100 Series Humidity and Temperature Transmitter
Vaisala INTERCAP® Humidity and Temperature
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT100
A
0 0
A
Transmitter type
Wall mount/fixed probe
Remote probe with 3 m cable
B
Remote probe with 5 m cable
C
Remote probe with 10 m cable
D
Remote probe with 10 m cable + 10 m extension
E
No display
0
Display
Display *)
1
Output channels ***)
RH or Td only
1
Two output parameters
2
2-wire loop-powered
A
Signal output ***)
4... 20 mA
3-wire
0... 1 V
B
3-wire
0... 5 V
C
3-wire
0... 10 V
D
Define scale:
3-wire
0… ______________ V **)
X
SPECIAL
Probe HMP60
Parameter for Ch1 ***)
Parameter for Ch2 ***)
8
9
10
11
12
13
No
T
Define scale
SPECIAL
7
RH
Td
Define quantity
Output units ***)
Humidity sensor type
Sensor protection
Transmitter installation
Installation kit for probe
Cable bushings
Operating manual
language
0…100 %RH
-20...+80°C
__________ Scale
(-4...+176°F)
_____________
Vaisala HUMICAP®
Humidity and Temperature Probe
1 Output signals
$100
$100
2 Measured parameter for channel 1
1
6
X
3 Measured parameter for channel 2
0
2
3
4
5
7
X
-40...+60°C
(-40...+140°F)
-20...+80°C
(-4...+176°F)
0...+60°C
(+32...+140°F)
-40...+80°C
(-40...+176°F)
0...+50°C
('32...+122°F)
_______________________
Metric
Non-metric
General purpose
Plastic grid
Plastic grid with filter
Sintered stainless steel filter
Wall mounting plate (plastic)
Wall mounting plate (Aluminum)
Outdoor installation kit (Weather shield)
No accessories
Duct installation kit
DTR502B with probe installation kit
Cable gland for 2…6 mm cable
Stainless steel liquid tight PG9
Conduit fitting NPT 1/2"
No manual
English
PRICE
$430
$580
$600
$620
$710
4 Sensor protection
5 Accessories
1
2
3
A
B
C
$30
$110
1
2
3
D
Scaling for 4..20 mA converter (channel 1 only)
I
RS485
R
None - RS485
0
RH
1
T
(-40 ... +60°C)
2
Td
(-40 ... +60°C)
3
None - RS485 or current interface
0
RH
1
T
(-40 ... +60°C)
2
Td
(-40 ... +60°C)
3
Plastic grid with filter
(DRW010525)
A
Plastic grid
(DRW010522)
B
Stainless steel sintered filter
(HM46670SP)
C
No accessories
No cable
9 Loop power converter
(18350SP)
1
A
1
(HMP50Z032)
2
$10
60 °C cable 3 m
(HMP50Z30A)
3
$20
180 °C FEP cable 3m
(226902)
F
A
Multilingual quick guide
B
No converter
0
(ui-converter -1)
1
$20
$310
$45
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
HMP60 A
1
2
A
0
A
1
B
0
Example of order code with typical settings:
HMT100 A 0 2 A 1 2 2 A 2 A 1 A B 0 0
HMP100 Probe for HMT100 Series
HMP100 A
A
(DRW010522)
(DRW010525)
(HM46670SP)
$60
No user guide
0
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
$45
0
60 °C cable 0.3 m
4...20 mA loop power converter
A
B
(M210701EN-A)
*) backlight not available with 4…20 mA output
**) value must be between 0…10 V
***) These options can not be modified in the field.
1
2
3
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings:
HMP100 A 2
178
1 ...5V
7 Probe cable length
0
HUMICAP®180
Plastic grid
Plastic grid with filter
Stainless steel sintered filter
C
A
B
C
14
15
Vaisala HUMICAP® Probe
Humidity sensor
Sensor protection
B
0...5 V
Intercap
8 User guide
$240
A
0...2.5 V
6 Humidity sensor
A
(215619)
(HMT100DTR502B)
0...1 V
Pair of plastic nuts
1
2
HUMICAP180
(DRW010522)
(DRW010525)
(HM46670SP)
(GM45160)
(DRW010712)
(215109)
PRICE
HMP60
PRICE
$280
Acessories and Spare Parts:
Description:
Order Code:
Probe mounting flange
226061
PRICE
$51
Mounting bracket with lid
225979
$85
Probe mounting clamp set (10 pcs)
226067
$102
USB cable
219690
$100
Plastic nuts
18350SP
(enclosure for 4-20mA loop power converter)
$10
179
HMI41Set Humidity & Temperature Indicator and Probe
Vaisala HUMICAP® Humidity and Temperature
1
Probe HMP110
Vaisala HUMICAP®
Humidity and Temperature Probe
1 Output signals
2 Measured parameter for channel 1
PRICE
HMP110
0...1 V
$480
A
0...2.5 V
B
0...5 V
C
1 ...5V
D
Scaling for 4..20 mA converter (channel 1 only)
I
RS485
R
None - RS485
0
RH
3 Measured parameter for channel 2
4 Sensor protection
5 Accessories
(-40 ... +80°C)
5
Td
(-40 ... +80°C)
6
None - RS485 or current interface
0
Selections in bold are included in the prices of the basic versions.
RH
1
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
T
(-40 ... +80°C)
5
Td
(-40 ... +80°C)
6
Plastic grid with filter
(DRW010525)
(DRW010522)
B
Stainless steel sintered filter
(HM46670SP)
C
No accessories
Pair of plastic nuts
Humicap180R
7 Probe cable length
No cable
9 Loop power converter
$45
0
(18350SP)
1
C
1
60 °C cable 0.3 m
(HMP50Z032)
2
$10
60 °C cable 3 m
(HMP50Z30A)
3
$20
80 °C cable 1.5 m
(225777)
4
$35
80 °C cable 3 m
(225229)
5
$45
180 °C FEP cable 3m
(226902)
F
$60
No user guide
A
Multilingual quick guide
B
No converter
4...20 mA loop power converter
2
3
HMI41SET
PRICE
$860
$1,120
$980
$1,120
$760
$780
A
B
C
D
E
F
(MI70CASE2)
(210614)
1
3
5
$160
$60
A
B
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
HMI41SET D 5 B
A
Plastic grid
6 Humidity sensor
8 User guide
1
T
Vaisala HUMICAP® Humidity and Temperature Indicator
1 Probe
HMP41
HMP42
HMP45
HMP46
HMP44
HMP44L
2 Carrying Case for HMI41
no case
and probe(s)
Aluminum case for HMP41/42/45/46
Rigid plastic case for HMP41/42/45/46
3 Manual
no manual
English
0
(ui - converter -1)
1
$45
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Accessories and Spare Parts: Descripton:
Membrane filter tube set (5 pcs) for the HMP42 probe
Steel grid for the HMP42 probe
Serial interface cable for HMI41
Indicator only
Calibration adapter for HMP42 probe
Rubber sleeve set (10 pcs) for HMP42 probe
Connection Cables for:
HMD/W60/70
HMP230 Series
HMD/W20/30
HMT330, HMT360 and HMT100
with over voltage-barrier HMT360 Series
Order Code:
19858HM
19867HM
19446ZZ
HMI41
HM37067
19809HM
PRICE
$25
$45
$40
$460
$20
$20
19116ZZ
19164ZZ
19165ZZ
25917ZZ
25905ZZ
$30
$30
$30
$30
$30
HMI41 Spare Probes Only: HMP41
HMP42
HMP45
HMP46
HMP44
HMP44L
$400
$660
$520
$660
$300
$320
Example of order code with typical settings:
HMP110 A
Acessories and Spare Parts:
1
5
A
0
C
1
B
0
Description:
Order Code:
Probe mounting flange
226061
PRICE
$51
Mounting bracket with lid
225979
$85
Probe mounting clamp set (10 pcs)
226067
$102
USB cable
219690
$100
Plastic nuts
18350SP
(enclosure for 4-20mA loop power converter)
180
$10
181
HMK15 Humidity Calibrator
HM70 Hand-held Humidity and Temperature Meter
®
Vaisala HUMICAP Hand-Held Humidity and Temperature Meter
1 Indicator type
no indicator *
rechargable with Euro AC-adapter
rechargable with US AC-adapter
alkaline batteries only
2 Indicator accessories no indicator accessories
MI70LINK(software with RS232 cable)
analog output-signal cable
MI70LINKand analog output-signal cable
MI70LINK software with USB cable
3 Probe type
HMP75
HMP75B (chemical purge and sensor preheating)
HMP76
HMP76B (chemical purge and sensor preheating)
HMP77
HMP77B (chemical purge and sensor preheating)
4 Calibration
at room temperature
5 Probe accessories
no accessories
probe holder for HMP76/76B**
6 Connection cable
no connection cable
connection cable to 60/70/140 series transmitters
to a transmitter
connection cable to HMP230 series
connection cable to 20/30/130 series transmitters
connection cable to HMT330 series / HMT100
7 Carrying case
no carrying case
carrying case for indicator and probe (HMP75/77/77B)
carrying case for indicator and probe (HMP75/76/76B/77/77B)***
8 Manual language
no manual
English
* select item A, if only probe is ordered
** used in field calibration of duct 60/70 and 20/30 transmitters
*** case for two probes
(MI70USADAPTER + 26755)
(18950 (4 pieces))
(MI70LINK)
(27168ZZ)
(MI70LINK + 27168ZZ)
(219687)
(HM36915)
(HMA6070)
(27159ZZ)
(HMA2030)
(211339)
MI70CASE
MI70CASE2
1 2 3 4 5 6 7 8
HM70
1
A
B
D
K
0
1
2
3
4
A
F
B
C
D
E
1
A
B
0
1
2
3
4
A
B
C
A
B
TOTAL
QTY
TOTAL VALUE
$840
$840
$780
$60
$35
$95
$90
$690
$800
$840
$950
$1,020
$1,120
$25
$60
$60
$60
$60
$140
$200
Example of order code with typical settings:
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
HMK15
(19766HM)
(19729HM)
$550
A
B
$140
0
1
2
(19730HM)
(19731HM)
(19732HM)
$40
$80
0
1
2
$40
$80
0
1
2
$40
$80
0
1
2
$40
$80
A
B
(19767HM)
$20
0
1
(HM27032)
(19728HM)
(25130HM)
$140
1
2
A
B
C
TOTAL
QTY
TOTAL VALUE
Shaded sectionss indicate typical selections.
HM70 D 4 A 1 A 0 B B
182
1
Vaisala Humidity Calibrator
Salt chamber
no additional salt chamber
an additional salt chamber
LiCl salt
no LiCl
LiCl (11 %RH) for one chamber
LiCl (11 %RH) for two chambers
MgCl2 salt
no MgCl2
MgCl2 (33%RH) for one chamber
MgCl2 (33%RH) for two chambers
NaCl salt
no NaCl
NaCl (75 %RH) for one chamber
NaCl (75%RH) for two chambers
K2SO4 salt
no K2SO4
K2SO4 (97 %RH) for one chamber
K2SO4 (97 %RH) for two chambers
Ion exchanged water no water
water for three chambers
Carrying bag
no bag
carrying bag
Thermometer
with mercury
with red capillary liquid
Manual
no manual
English
French
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Order Code:
MI70USADAPTER
26755
1
9
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Accessories and Spare Parts: Description:
US Adapter
Battery NiMH 4.8 for MI70
Probe Accessories: HMP75
Plastic PC grid filter
Membrane filter
Sintered bronze filter
HMP76/77
Plastic PPS grid filter
Sintered stainless steel filter
Sintered bronze filter
(HMP76 standard)
PPS grid with SS netting
(HMP77 standard)
With Two Standard Chambers
PRICE
Example of order code with typical settings:
HMK15 A 1 0 1 0 A
PRICE
$60
$30
6221
10159HM
DRW212987SP
$30
$30
$50
DRW010276SP
HM47280SP
$30
$50
DRW212987SP
$50
DRW010281SP
$30
Bulk Salt Accessories:
Description
Lithium Chloride (LiCI)
Sodium Chloride (NaCI)
Potassium Sulfate (K2 SO4)
Order Code
5236
4102
2827
0
1
Size
250 g
1 kg
1 kg
B
PRICE
$80
$40
$60
183
DMW19 Dewpoint Wall Transmitter
DMT342 Dewpoint and Temperature Transmitter
1
Vaisala HUMICAP® Dewpoint Transmitter
1
0…1 V
Analog output
0…5 V
4…20 mA
2
-20…+60 °C Td
Dewpoint range
-10 …+40 °C Td
for analog output
0…+160 °F Td
+30…+130 °F Td
free scaling (specify):
3
User Guide
No user guide
Multilingual user guide
2
PRICE
$630
DMW19
A
B
C
1
2
3
4
1
2
4
5
X
__________________________
With Small Size Flanged Probe for use with sampling cell
3
5
6
7
A
X
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings:
DMW19 A 1
Vaisala DRYCAP® Dewpoint and Temperature Transmitter
Transmitter type
DMT342
Probe Cable lengths
2 m cable (6.6 ft)
5 m cable (16.4 ft)
10 m cable (32.8 ft)
Measurement
Dewpoint + PPM + Mixing ratio
Parameters
Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature
Display
No display
Graphic Display with Keypad
10...35 VDC, 24 VAC
Power Supply
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
Universal AC -power (100....240 VAC)
Universal AC -power (100....240 VAC) + US -power cord
External US AC-adapter (for LAN/WLAN interface in USA)
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
Analog Output Scaling
No 3rd analog output
for Ch1&Ch2(&Ch3)
Dewpoint (-80...+20 °C)
( -112...+68 °F)
Dewpoint (-60...+20 °C)
( -76...+68 °F)
Dewpoint (-50...+50 °C)
( -58...+122 °F)
Temperautre (0...+80 °C)
(+32...+176 °F)
PPMv (0...1000 ppm)
PPMw (0...1000 ppm)
Mixing ratio (0...30g/kg d.a)
(0...210gr/lbs)
Relative humidity (0...100%)
SPECIAL
Define scale for
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
A 0
PRICE
$2,570
$160
$370
$320
A
B
C
D
K
$80
$200
$210
$60
1
2
3
4
5
only for channel 1
only for channel 1
Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____)
X
B
C
D
E
G
H
J
K
B
C
D
E
A
B
C
D
E
J J
K K
X X X
Ch1:_____________ Ch2:_____________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A, if not needed
8
9
10
11
Operating Pressure
12
Output Units
13
Additional Option
14
1 2 3 4 5
DMT340 2
0
2
B
C
D
0
(for temperatures below 0° C)
A
(for temperatures above 0° C)
B
0
1
(HMT300PWS)
(DCDC-1)
(Power-1)
(Power-1 & 215991)
Not IP65
2nd Additional Option
15
User Cable Connection
16
Transmitter Housing
Installation
1 bar (abs)
(14.5 psi abs)
3 bar
(43.5)
5 bar
(72.5)
7 bar
(101.5)
9 bar
(130.5)
special ( max 50 bar / 725 psi )**
(bar / psi)(abs)
Metric units
Non-metric units
No Additional Option
Alarm Relay Output
(Relay-1)
RS-485 Serial Interface with Galvanic Isolation
(RS485-1)
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (wireless Ethernet) interface + antenna
Data Logging Module
No Additional Option
Alarm Relay Output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
Data Logging Module
Not possible if data logger has already been chosen in 11
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212142)
Connector (M12, 8 pin) and Plug for User's Cable
(212416)
Wall Mounting
Wall Mounting (for adapting to DMP248)
(214829)
Pipe/Pole Installation
(215108)
Pipe/Pole Installation with Rain Shield for Outdoor Installations
(215109)
DIN-Rail Installation
(215094)
DRYCAP® 180M
Sintered stainless steel filter
(HM47280SP)
Stainless steel filter for vacuum
(HM47453SP)
No Accessories
Sample Cell
( HMT302SC )
No manual
English
No PC Accessories
MI70LINK software for Windows® with RS232 service cable
(215005)
MI70LINK software for Windows® with USB service cable
(219916)
Standard Calibration, with NIST traceable certificate
17
18
Dewpoint Sensor
Sensor Protection
19
20
Probe Installation
Accessories
User's guide language
21
PC Accessories
22
23
Calibration
For future use
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales
1
2
3
4
5
X
A
B
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
1
2
3
4
$60
$60
A
B
C
D
E
$90
$100
$110
$90
1
A
B
0
1
$80
A
B
0
2
4
$60
$90
A
0
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
2 B 0 B 1 A 1 B E A 1 B 0 0 1 A 1 A 1 B 0 A 0
DMT340
184
185
DMT344 Dewpoint and Temperature Transmitter
DMT347 Dewpoint and Temperature Transmitter
For Pressurized Processes
1
2
3
4
5
6
7
With Small Pressure-tight Probe
Vaisala DRYCAP® Dewpoint and Temperature Transmitter
Transmitter type
DMT344
Probe Cable lengths
2 m cable (6.6 ft)
5 m cable (16.4 ft)
10 m cable (32.8 ft)
Measurement
Dewpoint + PPM + Mixing ratio
Parameters
Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature
Display
No display
Graphic Display with Keypad
Power Supply
10...35 VDC, 24 VAC
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
Universal AC -power (100....240 VAC)
Universal AC -power (100....240 VAC) + US -power cord
External US AC-adapter (for LAN/WLAN interface in USA)
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
Analog Output Scaling
No 3rd analog output
for Ch1&Ch2(&Ch3)
Dewpoint (-80...+20 °C)
( -112...+68 °F)
Dewpoint (-60...+20 °C)
( -76...+68 °F)
Dewpoint (-50...+50 °C)
( -58...+122 °F)
Temperautre (0...+80 °C)
(+32...+176 °F)
PPMv (0...1000 ppm)
PPMw (0...1000 ppm)
Mixing ratio (0...30g/kg d.a)
(0...210gr/lbs)
Relative humidity (0...100%)
SPECIAL
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
A 0
Define scale for
12 Output Units
13 Additional Option
14 2nd Additional Option
15 User Cable Connection
16 Transmitter Housing
Installation
17 Dewpoint Sensor
18 Sensor Protection
19 Probe Installation
Accessories
20 User's guide language
21 PC Accessories
22 Calibration
23 For future use
PRICE
$2,960
$160
$370
A
B
C
D
K
$80
$200
$210
$60
1
2
3
4
5
only for channel 1
only for channel 1
B
C
D
E
G
H
J
K
B
C
D
E
A
B
C
D
E
J J
K K
** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales
6
7
SPECIAL
8
9
10
11 Operating Pressure
1
2
3
4
5
X
12 Output Units
13 Additional Option
A
B
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
1
2
3
4
14 2nd Additional Option
15 User Cable Connection
16 Transmitter Housing
$60
$60
A
B
C
D
E
$90
$100
$110
$90
1
Installation
17 Dewpoint Sensor
18 Sensor Protection
19 Probe Installation
Accessories
A
B
20 User's guide language
2
3
21 PC Accessories
A
B
0
2
4
A
0
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
DMT340 4 H 0 B 1 A 1 B E A 1 B 0 0 1 A 1 A 3 B 0 A 0
$60
$90
1 2 3 4 5
7
0
7
S
T
U
0
(for temperatures below 0° C)
A
(for temperatures above 0° C)
B
0
1
(HMT300PWS)
(DCDC-1)
(Power-1)
(Power-1 & 215991)
Not IP65
DMT340
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
A 0
22 Calibration
23 For future use
PRICE
$2,460
$160
$370
$320
A
B
C
D
K
$80
$200
$210
$60
1
2
3
4
5
only for channel 1
only for channel 1
Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____)
Define scale for
Channel 1
Channel 2
Channel 3, choose A, if not needed
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
3
4
X X X
Ch1:_____________ Ch2:_____________ Optional Ch3:______________
1 bar (abs)
(14.5 psi abs)
3 bar
(43.5)
5 bar
(72.5)
7 bar
(101.5)
9 bar
(130.5)
special ( max 50 bar / 725 psi )**
(bar / psi)(abs)
Metric units
Non-metric units
No Additional Option
Alarm Relay Output
(Relay-1)
(RS485-1)
RS-485 Serial Interface with Galvanic Isolation
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (wireless Ethernet) interface + antenna
Data Logging Module
No Additional Option
Alarm Relay Output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3 (AOUT-1)
Data Logging Module
Not possible in the data logger has already been chosen in item 11
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
(212142)
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212416)
Connector (M12, 8 pin) and Plug for User's Cable
Wall Mounting
Wall Mounting (for adapting to DMP248)
(214829)
Pipe/Pole Installation
(215108)
Pipe/Pole Installation with Rain Shield for Outdoor Installations
(215109)
DIN-Rail Installation
(215094)
DRYCAP® 180M
Sintered stainless steel filter
(HM47280SP)
Stainless steel filter for vacuum
(HM47453SP)
FITTING BODY M22 x 1.5
(17223)
FITTING BODY NPT1/2"
(17225)
No manual
English
No PC Accessories
MI70LINK software for Windows® with RS232 service cable
(215005)
MI70LINK software for Windows® with USB service cable
(219916)
Standard Calibration, with NIST traceable certificate
Vaisala DRYCAP® Dewpoint and Temperature Transmitter
DMT340
2 m cable (6.6 ft)
5 m cable (16.4 ft)
10 m cable (32.8 ft)
Measurement
Dewpoint + PPM + Mixing ratio
Parameters
Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature
Display
No display
Graphic Display with Keypad
10...35 VDC, 24 VAC
Power Supply
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
Universal AC -power (100....240 VAC)
Universal AC -power (100....240 VAC) + US -power cord
External US AC-adapter (for LAN/WLAN interface in USA)
Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
Analog Output Scaling
No 3rd analog output
for Ch1&Ch2(&Ch3)
Dewpoint (-80...+20 °C)
( -112...+68 °F)
Dewpoint (-60...+20 °C)
( -76...+68 °F)
Dewpoint (-50...+50 °C)
( -58...+122 °F)
Temperautre (0...+80 °C)
(+32...+176 °F)
PPMv (0...1000 ppm)
PPMw (0...1000 ppm)
Mixing ratio (0...30g/kg d.a)
(0...210gr/lbs)
Relative humidity (0...100%)
1 Transmitter type
2 Probe Cable lengths
5
$320
Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____)
8
9
10
11 Operating Pressure
186
1 2 3 4 5
DMT340
4
0
4
H
J
K
0
(for temperatures below 0° C)
A
(for temperatures above 0° C)
B
0
1
(HMT300PWS)
(DCDC-1)
(Power-1)
(Power-1 & 215991)
Not IP65
B
C
D
E
G
H
J
K
B
C
D
E
A
B
C
D
E
J J
K K
X X X
Ch1:_____________ Ch2:_____________ Optional Ch3:______________
Channel 1
Channel 2
Channel 3, choose A, if not needed
1 bar (abs)
(14.5 psi abs)
3 bar
(43.5)
5 bar
(72.5)
7 bar
(101.5)
9 bar
(130.5)
special ( max 50 bar / 725 psi )**
(bar / psi)(abs)
Metric units
Non-metric units
No Additional Option
Alarm Relay Output
(Relay-1)
RS-485 Serial Interface with Galvanic Isolation
(RS485-1)
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (wireless Ethernet) interface + antenna
Data Logger Module
No Additional Option
Alarm Relay Output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3
(AOUT-1)
Data Logger Module
Not possible if the data logger module has already been chosen in item 11
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212142)
Connector (M12, 8 pin) and Plug for User's Cable
(212416)
Wall Mounting
Wall Mounting (for adapting to DMP248)
(214829)
Pipe/Pole Installation
(215108)
Pipe/Pole Installation with Rain Shield for Outdoor Installations
(215109)
DIN-Rail Installation
(215094)
DRYCAP® 180M
Sintered stainless steel filter
(HM47280SP)
Stainless steel filter for vacuum
(HM47453SP)
Swagelok connector ISO 3/8"
(SWG12ISO38)
Swagelok connector NPT 1/2"
(SWG12NPT12)
SWG12ISO12
Swagelok connector ISO 1/2"
No manual
English
No PC Accessories
MI70LINK software for Windows® with RS232 service cable
(215005)
MI70LINK software for Windows® with USB service cable
(219916)
Standard Calibration, with NIST traceable certificate
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
1
2
3
4
5
X
A
B
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
1
2
3
4
$60
$60
A
B
C
D
E
$90
$100
$110
$90
1
A
B
4
5
K
A
B
0
2
4
$60
$90
A
0
TOTAL
QTY
TOTAL VALUE
** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales
Example of order code with typical settings:
DMT340 7 S 0 B 1 A 1 B E A 1 B 0 0 1 A 1 A 5 B 0 A 0
187
DMT345 Dewpoint Transmitter
DMT348 Dewpoint and Temperature Transmitter
For measurement in hot and dry processes
For Pressurized Pipelines
Vaisala DRYCAP® Dewpoint and Temperature Transmitter
1 Transmitter type
DMT348
2 Probe Cable lengths
2 m cable (6.6 ft) for standard probe
5 m cable (16.4 ft) for standardp probe
10 m cable (32.8 ft) for standard probe
2 m cable (6.6 ft) for long probe
5 m cable (16.4 ft) for long probe
10 m cable (32.8 ft) for long probe
34 Measurement
Dewpoint + PPM + Mixing ratio
Parameters
Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature
5 Display
No display
Graphic Display with Keypad
6 Power Supply
10...35 VDC, 24 VAC
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
Universal AC -power (100....240 VAC)
Universal AC -power (100....240 VAC) + US -power cord
External US AC-adapter (for LAN/WLAN interface in USA)
7 Analog Output Signal
4... 20 mA
for Ch1&Ch2(&Ch3)
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
Analog Output Scaling
No 3rd analog output
for Ch1&Ch2(&Ch3)
Dewpoint (-80...+20 °C)
( -112...+68 °F)
Dewpoint (-60...+20 °C)
( -76...+68 °F)
Dewpoint (-50...+50 °C)
( -58...+122 °F)
Temperautre (0...+80 °C)
(+32...+176 °F)
PPMv (0...1000 ppm)
PPMw (0...1000 ppm)
Mixing ratio (0...30g/kg d.a)
(0...210gr/lbs)
Relative humidity (0...100%)
SPECIAL
DMT340
1
8
8
2
3
0
4
5
8
9
10
11 Operating Pressure
12 Output Units
13 Additional Option
14 2nd Additional Option
15 User Cable Connection
16 Transmitter Housing
Installation
17 Dewpoint Sensor
18 Sensor Protection
19 Probe Installation
Accessories
20 User's guide language
21 PC Accessory
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
A 0
V
W
X
1
2
3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
PRICE
$2,790
$160
$370
$120
$260
$460
0
(for temperatures below 0° C)
(for temperatures above 0° C)
A
B
2 Probe cable length
3
-
$320
A
B
C
D
K
$80
$200
$210
$60
1
2
3
4
5
only for channel 1
only for channel 1
5 m cable (16.4 ft)
M
10 m cable (32.8 ft)
N
7 Analog output
B
C
D
E
G
H
J
K
B
C
D
E
A
B
C
D
E
J
K
J
K
X
X
X
0
1
10...35 VDC, 24 VAC with galvanic isolation for outputs
(DCDC-1)
Universal AC -power (100....240 VAC)
(Power-1)
C
$200
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 & 215991)
D
$210
Ethernet US AC-adapter (for LAN/WLAN intrface in USA)
4... 20 mA
A
B
Not IP65
$80
$60
K
1
0... 20 mA
2
0... 1 V
3
0... 5 V
4
0... 10 V
5
No 3rd analog output
parameter and scaling
for Ch1&Ch2
Dewpoint (0...+100 °C)
(+32...+212 °F)
1 1 1
Mixing ratio (0...1000g/kg)
(0...7000gr/lbs)
2 2 2
T (0...140 °C)
(+32...284 °F)
A
3 3 3
K K K
Define parameter (unit) for Ch1:________________(_____) Ch2:_______________(_____)
X X X
Ch1:______________________ Ch2:______________________
8
Channel 1
9
Channel 2
Channel 3, choose A, if not needed
11 Operating pressure
12 Output units
1
2
3
4
5
X
$320
(HMT300PWS)
10
1 bar (abs)
(14.5 psi abs)
3 bar
(43.5)
5 bar
(72.5)
7 bar
(101.5)
9 bar
(130.5)
special ( max 50 bar / 725 psi )**
(bar / psi)(abs)
Metric units
Non-metric units
No Additional Option
Alarm Relay Output
(Relay-1)
(RS485-1)
RS-485 Serial Interface with Galvanic Isolation
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (wireless Ethernet) interface + antenna
Data Logger Module
No Additional Option
Alarm Relay Output
(Relay-1)
3rd Analog output
Choose also analog output signal for Ch3 (AOUT-1)
Data Logger Module
Not possible if data logger module has already been chosen in item 11
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
(214728SP)
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
(212142)
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212416)
Connector (M12, 8 pin) and Plug for User's Cable
Wall Mounting
Wall Mounting (for adapting to DMP248)
(214829)
Pipe/Pole Installation
(215108)
Pipe/Pole Installation with Rain Shield for Outdoor Installations
(215109)
DIN-Rail Installation
(215094)
DRYCAP® 180M
Sintered stainless steel filter
(HM47280SP)
Stainless steel filter for vacuum
(HM47453SP)
(ISOFITBODASP)
Fitting body R 1/2" ISO with leak screw
(DRW212076SP)
Fitting body R 1/2" ISO ( no leak screw )
(NPTFITBODASP)
Fitting body NPT1/2" ( no leak screw )
(THREADSETASP)
Two Fitting Bodies: R 1/2" ISO with leak screw + NPT1/2"
(DMT242SC)
Sampling Cell
(DMT242SC2)
Sampling Cell with Swagelok connectors
(DRW212076 + BALVALVE-1)
Ball Valve Set for Pressurized Pipelines
Flange for Duct Installation
(DM240FA)
No manual
English
No PC Accessories
MI70LINK software for Windows® with RS232 service cable
(215005)
MI70LINK software for Windows® with USB service cable
(219916)
Standard Calibration, with NIST traceable certificate
$370
10...35 VDC, 24 VAC
Define scale for
Channel 1
Channel 2
Channel 3, choose A, if not needed
1
ambient
Metric units
A
Non-metric units
13 Additional feature
A
B
14 Additional feature 2
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
1
2
3
4
None
(Relay-1)
1
$180
(RS485-1)
2
$160
6
$350
Data Logging Module
None
15 Interface cable connection
$90
$100
$110
$90
A
B
C
D
E
F
G
H
$25
$80
$100
$80
$80
A
B
0
2
4
22 Calibration
23 For future use
Selections in bold are included in the prices of the basic versions
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
$60
90
A
0
TOTAL
QTY
TOTAL VALUE
0
Alarm Relay Output
(Relay-1)
1
$180
3rd analog output
(AOUT-1)
3
$160
4
$260
5
$320
WLAN (wireless ethernet) interface + antenna
installation
A
B
0
Alarm Relay Output
LAN (ethernet) interface + 2 m cable (RJ45)
16 Transmitter housing
1
B
RS-485 Serial Interface with Galvanic Isolation
Data Logging Module
Cable gland (for 8...11 mm cable) (for 0.315...0.433 inch cable)
Not possible if the data logger module has already been chosen in item 13
(214728SP)
$350
1
Conduit fitting for wire conduit (NPT1/2")
(214780SP)
(212142)
3
$60
(212416)
4
$60
Wall Mounting
2
A
Wall Mounting with Quick Installation or on Junction Boxes
(214829)
B
$90
Pipe/Pole Installation
(215108)
C
$100
Pipe/Pole Installation with Rain Shield for Outdoor Installations
(215109)
D
$110
DIN-Rail Installation
(215094)
E
17 Sensor
DRYCAP®180S
18 Sensor Protection
Stainless steel sintered filter
19 Probe installation
None
20 User's guide
Flange
None
$90
2
(HM47280SP)
(21069)
A
0
7
$60
A
English
21 PC accessories
6
Connector (M12, 8 pin) and Plug with 5m Black Cable
Connector (M12, 8 pin) and Plug for User's Cable
A
B
C
D
E
PRICE
B
RH (0...100 %RH)
Ch1:_____________ Ch2:_____________ Optional Ch3:______________
C
$160
Analog output
SPECIAL
2 A
0
Dewpoint + mixing ratio + RH+ T
No display
6 Power supply
1
$3,140
L
Graphical display with keypad
0
1
0 B
5
2 m cable (6.6 ft)
-
5 Display
(HMT300PWS)
(DCDC-1)
(Power-1)
(Power-1 & 215991)
Not IP65
DMT340 5
Vaisala DRYCAP® Dewpoint Transmitter
DMT345
1 Transmitter type
4 Measurement parameters
Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____)
Define scale for
6
K
0
None
MI70LINK software for Windows® with RS232 service cable
(215005)
2
MI70LINK software for Windows® with USB service cable
(219916)
4
22 Calibration
Standard Calibration with NIST traceable certificate
23 Service contract
None
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
$60
$90
C
0
TOTAL
QTY
TOTAL VALUE
Example of order code with typical settings:
DMT340 5 L 0 B 1 A 1 1 3 A 1 B 0 0 1 A 2 A 0 K 0 C 0
** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales
Example of order code with typical settings
DMT340 8 V 0 B 1 A 1 B
188
E
A
1
B
0
0
1
A
1
A
C
B
0
A
0
189
DMT152 Dewpoint Transmitter
DMT346 Dewpoint Transmitter
1
With passive cooling for very hot processes
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
DMT340
Vaisala DRYCAP® Dewpoint Transmitter
1 Transmitter type
DMT346
2 Probe cable length
3
-
6
0 K
C
PRICE
2 m cable (6.6 ft)
P
Q
$160
10 m cable (32.8 ft)
R
$370
0
Dewpoint + mixing ratio (+ SSR + Ts)*
5 Display
No display
2
3
K
0
Graphical display with keypad
1
$320
10...35 VDC, 24 VAC
(HMT300PWS)
10...35 VDC, 24 VAC with galvanic isolation for outputs
(DCDC-1)
B
$80
Universal AC -power (100....240 VAC)
(Power-1)
C
$200
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 & 215991)
D
$210
External US AC-adapter (for LAN/WLAN interface in USA)
4... 20 mA
Not IP65
K
A
4
$60
1
0... 20 mA
2
0... 1 V
3
0... 5 V
4
0... 10 V
5
Analog output
No 3rd analog output
parameter and scaling
for Ch1&Ch2& Ch3
Dewpoint (0...+100 °C)
( +32...+212 °F)
1 1 1
Mixing ratio (0...1000g/kg)
(0...7000gr/lbs)
2 2 2
SPECIAL
Define parameter (unit) for Ch1:________________(_____) Ch2:_______________(_____)
Define scale for
1
$4,600
5 m cable (16.4 ft)
4 Measurement parameters
7 Analog output
2 D 6
6
-
6 Power supply
1
A
5
X X X
Ch1:______________________ Ch2:______________________
8
Channel 1
9
Channel 2
Channel 3, choose A, if not needed
10
11 Operating pressure
12 Output units
1
ambient
Metric units
A
Non-metric units
13 Additional feature
14 Additional feature 2
0
Alarm Relay Output
(Relay-1)
1
$180
RS-485 Serial Interface with Galvanic Isolation
(RS485-1)
2
$160
LAN (ethernet) interface + 2 m cable (RJ45)
4
$260
WLAN (wireless ethernet) interface + antenna
5
$320
Data Logging Module
None
6
16 Transmitter housing
installation
(Relay-1)
1
$180
3rd analog output: Choose also analog output parameter and scale for Ch3 (AOUT-1)
3
$160
Data Logging Module
Cable gland (for 8...11 mm cable)
6
Not possible if the data logger module has already been chosen in item 13
(for 0.315...0.433 inch cable)(214728SP)
(214780SP)
2
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212142)
3
Connector (M12, 8 pin) and Plug for User's Cable
(212416)
4
Wall Mounting
(214829)
B
$90
Pipe/Pole Installation
(215108)
C
$100
Pipe/Pole Installation with Rain Shield for Outdoor Installations
(215109)
D
$110
DIN-Rail Installation
(215094)
E
Stainless steel sintered filter for cooling set
(HM46780)
19 Probe installation accessories
With cooling set
None
(DMP246CS)
6
A
0
2
MI70LINK software for Windows® with USB service cable
(219916)
4
23 Service contract
None
$90
Stainless steel mesh filter
None
2 m (6.6 ft) cable with snap-on connector
3 m (9.8 ft) shielded cable with threaded connector
10 m (32.8 ft) shielded cable with threaded connector
None
2 m (6.6 ft) cable with snap-on connector
3 m (9.8 ft) shielded cable with threaded connector
10 m (32.8 ft) shielded cable with threaded connector
None
Sampling cell
Sampling cell with swagelok 1/4" male connectors
Sampling cell with quick connector and leak screw
Two-pressure sampling cell
Two-pressure sampling cell with venting coil DSC74C
None
Standard cardboard
Plastic case
None
Multilingual quick guide
Accessories:
PRICE
217490
4
5
6
7
8
9 10 11 12 13 14
PRICE
$1,510
$1,510
$1,510
A
B
C
1
2
A
B
C
D
E
B
C
D
E
X
Y
F
1
2
High
High
High
Level
B
C
D
E
X
Y
F
1
2
High
High
High
Level
1
2
0
1
X
bar
A
(211598)
(HMP50Z300SP)
(HMP50Z1000SP)
(211598)
(HMP50Z300SP)
(HMP50Z1000SP)
0
1
3
5
$10
$20
$60
0
1
3
5
$10
$20
$60
0
D
E
F
G
H
(DMT242SC)
(DMT242SC2)
(DSC74)
(DSC74B)
(DSC74C)
$80
$100
$100
$220
$340
A
1
2
$20
A
X
Total
Total value
Example of order code with typical settings:
DMT152 B 1 D B E 2 0 A 1 0 0 A 1 X
Example of order code with typical settings:
DMT340 6 P 0 K 1 A 1 1 2 A 1 B 0 0 1 A 2 D 6 K 0 C 0
Mounting flange for cooling set
3
* Indicates when autocalibration or sensor purge are activated - measurement is not active
TOTAL VALUE
Spare Parts:
2
DMT152
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
0
TOTAL
QTY
Shaded sections indicate typical selections.
* Sensor saturation rate (SSR) is a parameter describing the relative humidity at the sensor ( the margin to
condense). Ts is the temperature at the sensor. These parameters do not give information on the humidity or
$60
C
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
11 Installation accessories
ONLY for ISO1/2" thread
14 User' s guide
K
(215005)
Standard Calibration with NIST traceable certificate
10 Cable for RS485 line
and power supply
(Port II)
12 Special features
13 Package
D
None
MI70LINK software for Windows® with RS232 service cable
22 Calibration
8 Sensor Protection
9 Cable for analog outputs
and power supply
(Port I)
$90
2
English
190
$60
Wall Mounting with Quick Installation or on Junction Boxes
18 Sensor Protection
7
$60
A
DRYCAP®180S
21 PC accessories
$350
1
Conduit fitting for wire conduit (NPT1/2")
17 Sensor
20 User's guide
$350
0
Alarm Relay Output
15 Interface cable connection
6
B
None
Vaisala DRYCAP® Dewpoint Transmitter
Mechanical connection
ISO G1/2" thread
NPT 1/2" thread
UNF 3/4"-16 thread
Measurement parameters
Td/f, ppm
Td/f, ppm and ppmw for SF6 gas
Analog output Ch1 & Ch2
0...1 V
+ RS-485 as standard
0...5 V
0...10 V
4...20 mA
0...20 mA
Td/f
Analog output parameter
-80...+20 °C
-112...+68 °F
or function
Td/f
-100...0 °C
-148...+ 32 °F
for Ch1
ppm
0...100 ppm
ppm
0...500 ppm
Td/f , free scale
Define:
Low
ppm, free scale
Define:
Low
ppmw for SF6, free scale Define:
Low
Parameter
Alarm level on/off output Define:
Autocalibration & purge on/off output*
Td/f
Analog output parameter
-80...+20 °C
-112...+68 °F
or function
Td/f
-100...0 °C
-148...+ 32 °F
ppm
for Ch2
0...100 ppm
ppm
0...500 ppm
Td/f , free scale
Define:
Low
ppm, free scale
Define:
Low
ppmw for SF6, free scale Define:
Low
Alarm level on/off output Define:
Parameter
Autocalibration & purge on/off output*
Metric units (Celsius)
Output units
Non-metric units (Fahrenheit)
Pressure setting for
None - no ppm output
ppm calculation
Ambient 1 bara / 14,76 psia
Special (max 50 bar abs) Define pressure:
$300
Description
Connection cable for MI70 indicator
USB serial interface cable
Sealing ring set ISO (copper, 3 pcs)
Sealing ring set UNF (copper, 3 pcs)
Stainless steel mesh filter 8 μm
Loop-powered display
4…20mA/-80…20 °C Tdf, Nokeval 301
100...240 VAC external power supply
Order Code:
219980
219690
221524
221563
220957
226476
POWER-1
PRICE
$100
$100
$15
$15
$50
$250
$200
191
DMT242 Dewpoint Transmitter
DM70 Hand-held Dewpoint Meter
1 2 3 4 5 6 7
Vaisala DRYCAP® Dewpoint Transmitter
®
1 Dewpoint range
-80…+20 °C Td, DRYCAP 180M
®
for analog output
-60…+60 °C Td, DRYCAP 180M
®
Free scaling Td, DRYCAP 180M
DMT242
1 2 3 4 5 6 7 8
PRICE
$1,310
A
B
X
Define Td scale: ________ - ________ (°C)
1
2
®
-50...+50 °C Td, DRYCAP 180S (for refrigerator dryers)
S
Free scaling Td °C, DRYCAP®180S (for refrigerator dryers)
Y
Define Td scale: ________ - ________ (°C)
2 Analog Output Cable
No cable - connector only
2m (6.6 ft) Connection cable with DMT242 valve connector
3 Pressure setting
for optimized
accuracy
4 Sensor protection
5 PC accessories
6 Installation accessories
7 User's guide
1
(221475SP)
2
10 m (33 ft) Connection cable with DMT242 valve connector
(221476SP)
1 bar abs
(14.5 psi abs)
3 bar abs
(43.5 psi abs)
5 bar abs
(72.5 psi abs)
7 bar abs
(101.5 psi abs)
Define value: _______ bar abs
special (max 20 bar abs)
Stainless steel sintered filter (37 um)
Stainless steel filter for vacuum (below 0.5 bar abs)
None
Serial interface cable for service use, DMT242RS
None
Basic sampling cell
(DMT242SC)
Sampling cell, swagelok 1/4" male connectors
(DMT242SC2)
Sampling cell with quick connector and leak screw
(DSC74)
Two pressure sampling cell
(DSC74B)
Two pressure sampling cell with coil
(DSC74C)
NPT 1/2" adapter
(210662)
Duct installation flange
(DM240FA)
None
English
French
3
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
3
$40
$70
A
B
C
D
X
1
2
5
A
B
$50
0
1
2
3
4
5
6
9
$80
$100
$100
$220
$340
$25
$80
A
B
D
TOTAL
QTY
TOTAL VALUE
192
Order Code
226476
7
8
PRICE
A
B
D
K
$840
$840
$780
0
1
2
3
5
$60
$35
$95
$90
$1,630
$1,630
$2,410
A
B
C
0
1
2
3
4
5
6
$100
$1,560
$80
$100
$220
$340
A
B
C
D
E
M
$60
$60
$60
$60
$140
0
1
2
$140
$200
A
B
1
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
DM70 D 5 B 0 A 1 B 1
Accessories and Spare Parts:
DMT242 A 1 D 1 A 0 B
Description
Loop-powered display
4…20mA/-80…20 °C Tdf, Nokeval 301
6
* select item A, if only probe is ordered
** select item 0, if portable sampling system is selected
Example of order code with typical settings:
Accessories:
4
DM70
Vaisala DRYCAP® Hand-held Dewpoint Meter
no indicator*
Indicator type
rechargable with Euro AC-adapter
(MI70USADAPTER+26755)
rechargable with US AC-adapter
(18950 (4 pieces))
alkaline batteries only
Indicator accessories no indicator accessories
(MI70LINK)
MI70Link (software with RS232 cable)
(27168ZZ)
analog output-signal cable
MI70Link and analog output-signal cable
(MI70LINK + 27168ZZ)
MI70LINK software with USB cable
(219687)
Probe type
DMP74A -40…+60 °C Td
DMP74B -60…+20 °C Td
DMP74C -50…+20 °C Td (for SF6 gas)
Probe accessories
no accessories
sample cell (quick connect & leak screw)
(DSC74)
portable sampling system with case
(DSS70A)
sample cell (no fittings)
(DMT242SC)
sample cell (with swagelock connectors)
(DMT242SC2)
two-pressure sample cell
(DSC74B)
two-pressure sample cell with coil
(DSC74C)
Connection cable
no connection cable
(27160ZZ)
to a transmitter
connection cable to DMT242 transmitter
connection cable to DMP248 transmitter
(27159ZZ)
(211917ZZ)
connection cable to DMT142 transmitter
(211339)
connection cable to DMT340 transmitter
connection cables to DMP248 & DMT242 & DMT142 & DMT340
Carrying case
no carrying case**
(MI70CASE)
carrying case (Black ABS), for one probe
(MI70CASE2)
carrying case (Aluminium), for two probes
Manual language
No manual
English
Standard
Special Features
Price
$250
Description
10m extension cable for probe
SS sample cooling coil
SS sintered filter 12mm diameter
SS filter guard for vacuum applications
US Adapter
Battery NiMH 4.8 for MI70
Order Code
213107SP
DMCOIL
HM47280SP
HM47453SP
MI70USADAPTER
26755
PRICE
$60
$120
$50
$50
$60
$30
193
1
2
3
4
5
6
7
8
9
10
MMT332 Moisture and Temperature Transmitter for Oil
MMT337 Moisture and Temperature Transmitter for Oil
for high pressure applications
With Small Pressure-tight Probe
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Vaisala HUMICAP® Moisture and Temperature Transmitter
MMT330
2
0 E
2
A 1
Transmitter type
MMT332
2
Probe cable length
2 m cable
B
5 m cable
C
10 m cable
D
----None
0
Measurement parameters
aw+T
E
Display
No display
0
Graphic LCD with backlight
1
Power supply
10...35 VDC, 24 VAC
(HMT300PWS)
0
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog output
4... 20 mA
1
0... 20 mA
2
0... 1 V
3
0... 5 V
4
0... 10 V
5
Analog output
None
A
parameter and scaling
T
(range: see below)
C C C
aw (0...1)
for Ch1&Ch2(&Ch3)
(0...1)
P P P
Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____)
SPECIAL
X X X
Define scale for
Ch1:_____________ Ch2:____________ Optional Ch3:______________
PRICE
$1,980
1
2
$160
$370
3
4
5
$320
6
$80
$200
$210
$60
7
8
9
10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Vaisala HUMICAP® Moisture and Temperature Transmitter
MMT330 7
0 E
2
A 1
MMT337
Transmitter type
7
S
Probe cable length
2 m cable
5 m cable
T
10 m cable
U
----None
0
Measurement parameters
aw+T
E
Display
None
0
Graphic LCD with backlight
1
Power supply
10...35 VDC, 24 VAC
(HMT300PWS)
0
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
(DcDc-1)
1
Universal AC -power (100....240 VAC)
(Power-1)
2
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 and 215991)
3
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
9
Analog output
4... 20 mA
1
0... 20 mA
2
0... 1 V
3
0... 5 V
4
0... 10 V
5
Analog output
No 3rd analog output
A
parameter and scaling
T
(range: see below)
C C C
aw (0...1)
for Ch1&Ch2(&Ch3)
(0...1)
P P P
Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____)
SPECIAL
X X X
Define scale for
Ch1:_____________ Ch2:____________ Optional Ch3:______________
Analog output range
for temperature
NOTE:
- Choose option A, if no
T output is desired
12
13
14
15
16
17
18
SPECIAL
Output units
Additional feature
Additional feature 2
Interface cable connection
Transmitter housing
installation
Sensor
Sensor protection
19
20
Probe installation access.
User's guide
21
PC Accessories
22
23
Calibration
-----
None
(-40...+140°F)
-40...+60°C
(-40...+176°F)
-40...+80°C
(-40...+248°F)
-40...+120°C
(-40...+356°F)
-40...+180°C
(-4...+140°F)
-20...+60°C
(-4...+176°F)
-20...+80°C
(-4...+248°F)
-20...+120°C
(-4...+356°F)
-20...+180°C
(+32...+140°F)
0...+60°C
(+32...+ 212°F)
0...+100°C
(+32...248°F)
0...+120°C
(+32...356°F)
0...+180°C
(-76...+140°F)
-60...60 °C
__________________°C / ___________________ F
Metric
Non-metric
None
Relay output
RS-485 serial interface (galvanically isolated)
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logging module*)
None
Relay output
3rd Analog output
Choose also analog output signal for Ch3
Data logging module*)
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
Conduit fitting for wire conduit (NPT1/2")
Connector (M12, 8 pin) and plug with 5m cable
Connector (M12, 8 pin) and plug (screw terminal)
Wall Mounting
Wall mounting plate (for adapting to HMP228)
Pipe / pole installation
Pipe / pole installation with rain shield
DIN-rail installation
Special sensor for fluids
Stainless steel grid
Stainless steel grid (for applications with linear flow > 1 m/s)
None
None
English
None
Service cable for PC
MI70LINK software for Windows® + service cable for PC
Service cable for PC, USB
MI70LINK software for Windows® + USB service cable for PC
ISO9001 compliant calibration (factory calibration)
None
*) Choose data logging module only once (option 11 or 12)
11
A
B
C
D
E
F
G
H
J
K
L
M
N
P
X
(Relay-1)
(AOUT-1)
(214728SP)
(214780SP)
(212142)
(212416)
(214829)
(215108)
(215109)
(215094)
T output is desired
0
1
2
4
5
6
(19446ZZ)
(215005)
(219685)
(219916)
13
Additional feature
Additional feature 2
$180
$160
$350
15
A
B
C
D
Interface cable connection
$60
$60
16
0
1
2
3
4
$90
$100
$110
$90
D
E
A
B
$40
$60
$90
$90
A
1
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
MMT330
2 B 0 E 1 0 1 P C A L 2 0 0 A 0 2 D A B A A
Transmitter housing
installation
17
18
Sensor
Sensor protection
19
Probe installation
accessories
20
A
B
C
D
E
$320
$80
$200
$210
$60
21
22
23
User's guide
PC Accessories
Calibration
-----
None
(-40...+140°F)
-40...+60°C
(-40...+176°F)
-40...+80°C
(-40...+248°F)
-40...+120°C
(-40...+356°F)
-40...+180°C
(-4...+140°F)
-20...+60°C
(-4...+176°F)
-20...+80°C
(-4...+248°F)
-20...+120°C
(-4...+356°F)
-20...+180°C
(+32...+140°F)
0...+60°C
(+32...+ 212°F)
0...+100°C
(+32...248°F)
0...+120°C
(+32...356°F)
0...+180°C
(-76...+140°F)
-60...60 °C
__________________°C / ___________________ F
Metric
Non-metric
None
Relay output
RS-485 galvanic isolation
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logging module*)
None
Relay output
3rd Analog output Choose also analog output signal for Ch3
Data logging module*)
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
Conduit fitting for wire conduit (NPT1/2")
Connector (M12, 8 pin) and plug with 5m cable
Connector (M12, 8 pin) and plug (screw terminal)
Wall Mounting
Wall mounting plate (for adapting to HMP228)
Pipe / pole installation
Pipe / pole installation with rain shield
DIN-rail installation
Special sensor for fluids
Stainless steel grid
Stainless steel grid (for applications with linear flow > 1 m/s)
None
Swagelok connector NPT 1/2"
Swagelok connector ISO 3/8"
None
English
None
Service cable for PC
MI70LINK software for Windows + service cable for PC
Service cable for PC, USB
MI70LINK software for Windows® + USB service cable for PC
ISO9001 compliant calibration (factory calibration)
None
*) Choose data logging module only once (option 11 or 12)
A
B
C
D
E
F
G
H
J
K
L
M
N
P
X
1
2
(Relay-1)
(RS485-1)
(Relay-1)
(AOUT-1)
(214728SP)
(214780SP)
(212142)
(212416)
(214829)
(215108)
(215109)
(215094)
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
A
B
C
D
$60
$60
0
1
2
3
4
$90
$100
$110
$90
2
(HM47453SP)
(220752)
(SWG12NPT12)
(SWG12ISO38)
(M210566EN)
(19446ZZ)
(215005)
(219685)
(219916)
D
E
A
K
L
A
B
A
B
C
D
E
$40
$60
$90
$90
A
1
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
194
SPECIAL
Output units
14
0
1
3
6
A
(M210566EN)
12
$180
$160
$260
$320
$350
2
(HM47453SP)
(220752)
Analog output range
for temperature
NOTE:
- Choose option A, if no
1
2
(Relay-1)
(RS485-1)
$160
$370
Channel 1
Channel 2
Channel 3, choose A, if not needed
Channel 1
Channel 2
Channel 3, choose A, if not needed
11
PRICE
$1,810
1
Shaded sections indicate typical selections.
Example of order code with typical settings:
MMT330
7 S 0 E 1 0 1 P C A L 2 0 0 A 0 2 D K B A A
1
195
MMT338 Moisture and Temperature Transmitter for Oil
MM70 Hand-Held Moisture Meter for Oil
For pressurized pipelines
1
2
3
4
5
6
7
8
9
10
1 2 3 4 5
MMT330 8
0
8
V
W
X
1
2
3
0
E
0
1
(HMT300PWS)
(DcDc-1)
(Power-1)
(Power-1 and 215991)
Not IP65
Vaisala HUMICAP® Humidity and Temperature Transmitter
Transmitter type
MMT338
Probe cable length
2 m cable (6.6 ft) for standard probe
5 m cable (16.4 ft) for standard probe
10 m cable (32.8 ft) for standard probe
2 m cable (6.6 ft) for long probe
5 m cable (16.4 ft) for long probe
10 m cable (32.8 ft) for long probe
----None
Measurement parameters
aw+T
Display
No display
Graphic LCD with backlight
Power supply
10...35 VDC 24 VAC
Galvanic isolation for outputs 10...35 VDC 24 VAC
Universal AC -power (100....240 VAC)
Universal AC -power (100....240 VAC) + US -power cord
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Analog output
4... 20 mA
0... 20 mA
0... 1 V
0... 5 V
0... 10 V
Analog output
No 3rd analog output
parameter and scaling
T
(range: see below)
for Ch1&Ch2(&Ch3)
aw (0...1)
(0...1)
SPECIAL
Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____)
Define scale for
Ch1:_____________ Ch2:____________ Optional Ch3:______________
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
2
A 1 PRICE
$2,180
$160
$370
$120
$260
$460
$320
0
1
2
3
9
$80
$200
$210
$60
1
2
3
4
5
Analog output range
for temperature
NOTE:
- Choose option A, if no
T output is desired
12
SPECIAL
Output units
13
Additional feature
14
Additional feature 2
15
Interface cable connection
16
Transmitter housing
installation
17
18
Sensor
Sensor protection
19
Probe installation
accessories
20
User's guide
21
22
23
PC Accessories
Calibration
-----
None
(-40...+140°F)
-40...+60°C
(-40...+176°F)
-40...+80°C
-40...+120°C
(-40...+248°F)
(-40...+356°F)
-40...+180°C
(-4...+140°F)
-20...+60°C
(-4...+176°F)
-20...+80°C
(-4...+248°F)
-20...+120°C
(-4...+356°F)
-20...+180°C
(+32...+140°F)
0...+60°C
(+32...+ 212°F)
0...+100°C
(+32...248°F)
0...+120°C
(+32...356°F)
0...+180°C
(-76...+140°F)
-60...60 °C
__________________°C / ___________________ F
Metric
Non-metric
None
Relay output
RS-485 galvanic isolation
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logging module*)
None
Relay output
3rd Analog output Choose also analog output signal for Ch3
Data logging module*)
Cable gland (for 8...11mm cable)
(for 0.315...0.433 inch cable)
Conduit fitting for wire conduit (NPT1/2")
Connector (M12, 8 pin) and plug with 5m cable
Connector (M12, 8 pin) and plug (screw terminal)
Wall Mounting
Wall mounting plate (for adapting to HMP228)
Pipe / pole installation
Pipe / pole installation with rain shield
DIN-rail installation
Special sensor for fluids
Stainless steel grid
Stainless steel grid (for applications with linear flow > 1 m/s)
Ball valve set
Pressure fitting NPT1/2
Pressure fitting ISO 1/2
None
English
None
Service cable for PC
MI70LINK software for Windows + service cable for PC
Service cable for PC, USB
MI70LINK software for Windows® + USB service cable for PC
ISO9001 compliant calibration (factory calibration)
None
*) Choose data logging module only once (option 11 or 12)
12
13
14
(214728SP)
(214780SP)
(212142)
(212416)
(214829)
(215108)
(215109)
(215094)
6
7
A
8
9 10 11 12 13 14
0
PRICE
$840
$840
$780
$2,080
0
1
2
3
5
$60
$35
$95
$90
A
0
1
2
$80
$30
A
0
1
2
3
$60
$60
$60
A
B
$60
0
1
$200
A
B
0
TOTAL
QTY
TOTAL VALUE
* select item A, if only probe is ordered
** check the availability and special delivery time from your local Vaisala representative.
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
MM70 D
1
2
(Relay-1)
(AOUT-1)
7
8
11
A
B
C
D
E
F
G
H
J
K
L
M
N
P
X
(Relay-1)
(RS485-1)
2
3
4
5
6
9
10
A
C C C
P P P
X X X
Channel 1
Channel 2
Channel 3, choose A, if not needed
11
1
1 2 3 4 5
MM70
1 A 1 A
Vaisala HUMICAP® Hand-held Moisture Meter for Oil
no indicator *
A
Indicator type
B
rechargeable with Euro AC-adapter
(MI70USADAPTER+26755) D
rechargeable with US AC-adapter
(18950) (4 pieces)
K
alkaline batteries only
Reserved for future use
1
Probe type
MMP78
A
Sensor
Special sensor for fluids
(HUMICAP180L2)
1
Filter
Stainless steel filter
(HM47453SP)
A
Indicator accessories
no indicator accessories
(MI70LINK)
MI70LINK (software with RS 232 cable)
(27168ZZ)
Analog output-signal cable
MI70LINK and analog output-signal cable
(MI70LINK + 27168ZZ)
MI70LINK software with USB cable
(219687)
Calibration
at room temperature
Installation accessories
no accessories
(DRW212076 + BALLVALVE-1)
Ball valve set (incl. fitting body + blanking plug)
Connecting adapter to NPT ½"
(210662)
Measured variables
aw+T
Connection cable
no connection cable
Connection cable to HMP228
(27159ZZ)
to a transmitter
(DRW216050)
Connection cable to MMT318
(211339)
Connectioin cable to MMT300 Series
Probe cable length
1.9 meter
1.9 meter + extension cable 10m
(213107)
Carrying case
no carrying case
(211402)
Aluminum carrying case for indicator and 2 probes
Manual language
No manual
English
Reserved for future use
Accessories and Spare Parts:
0
1
2
4
5
6
$180
$160
$260
$320
$350
0
1
3
6
$180
$160
$350
A
B
C
D
1
A
Description:
Manual press tool
Plastic wrench
Calibration adapter for HMK15
Protecting cap MM78
Cable extension 10m
Ball valve assembly
Battery NiMH 4.8 for the MI70
MI70 US Adapter
1
A
5
A
0
A
0
Order Code:
HM36854SP
DRW216040SP
211302
DRW215988SP
213107SP
BALLVALVE-1
26755
MI70USADAPTER
A
1
B
0
PRICE
$30
$30
$30
$30
$60
$80
$30
$60
$60
$60
0
1
2
3
4
$90
$100
$110
$90
2
(HM47453SP)
(220752)
(DRW212076 + BALLVALVE-1)
(NPTFITBODASAP)
(DRW212076)
(M210566EN)
(19446ZZ)
(215005)
(219685)
(219916)
D
E
M
N
V
$80
A
B
A
B
C
D
E
$40
$60
$90
$90
A
1
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings:
MMT330 8 V 0 E 1 0 1 P C A L 2 0 0 A 0 2 D N B A A
196
1
197
Vaisala CARBOCAP® Carbon Dioxide Probe GMP343
GMT221 and GMT222 CO2 Transmitters
3
4
5
6
7
8
GMP343
A
B
9 10 11
PRICE
0
$2,800
$3,090
1
2
3
4
5
6
2
A
B
C
1
2
3
N
A
B
C
$40
$50
$60
0
1
2
$860
$60
N
A
B
C
$120
$80
$200
0
1
4
5
6
7
8
$80
N
A
$40
9
0
A
B
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
10
2
3
4
5
6
0
7
8
9
10
11 12
0
PRICE
$840
H
J
K
L
M
B
C
D
E
F
G
0
N
A
B
$10
$50
0
1
$70
A
B
$120
0
N
(25665GMSP) A
(210848GMSP) C
$80
$100
1
X
Example: custom setpoint for relay 1 1000 ppm CO2
-> Relay will be activated above 1000 ppm CO2
Alarm relay 2
A
X
setpoint not activated
custom setpoint for relay 2______ ppm / % CO2
Example: custom setpoint for relay 2 4% CO2
-> Relay will be activated above 4% CO2
Notes:
* The range 0...5000 ppm CO2 and 0…2 % CO2 have reduced accuracy specifications above 4000 ppm CO2.
11
** The analog output type may be selected and re-scaled using PC connection cable.
*** If the selection is RS-485, the device may be powered up in the RS-232 service mode for user settings. See user manual for details.
****This selection includes:
MI70 indicator with a rechargeable battery
AC adapter with AUS, EUR, UK and US plugs
MI70Link software with RS232 cable (PC<->MI70)
2 m interface cable (GMP343 <-> MI70)
***** PC connecton kit includes PC connection cable (213379) and USB adapter (USB-D9 Serial connection Cable, 219686)
GMP343
A 1
A
1
12
Accessories
Manual
no accessories
Serial COM adapter
no manual
English
(19040GM)
O
A
O
N
0
B
Order Code
GMP343BRACKET
GMP343FLANGE
GMP343FILTER
215521
GMP343ADAPTER
JUNCTIONBOX-8
GMP343Z200SP
GMP343Z600SP
GMP343Z1000SP
213379
DRW216050SP
219686
215519
215520
PRICE
$60
$110
$80
$120
$120
$50
$50
$70
$80
$80
$60
$90
$150
$150
$100
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
A
0
1
A
B
(* special accuracy specification
Accessories and Spare Parts:
Description
Included in the default configuration ----------------------- Wall mount bracket
Mounting flange
Included in the default configuration ----------------------- Standard diffusion filter (IP65) + filter cover
of the diffusion model
Diffusion filter (sintered filter, IP66) + filter cover
Calibration adapter
Junction box
Probe cable (with M12 type female conn.), 2 meter
Probe cable (with M12 type female conn.), 6 meter
Probe cable (with M12 type female conn.), 10 meter
PC connection cable
Interface cable for MI70, 2 meter
USB adapter (USV-D9 Serial connection cable)
Soil adapter kit for horizontal positioning (includes PTFE filter)
Soil adapter kit for vertical positioning (includes PTFE filter)
198
1
1
Vaisala CARBOCAP® CO2 Transmitter
GM T 22
Vaisala CARBOCAP® CO2 Transmitter
Measurement range
0…2 %CO2
1
(GMT221)
0...3 %CO2
1
0...5 %CO2
1
0...10 %CO2
1
0...20 %CO2
1
(GMT222)
0…2000 ppmCO2 adjusted at 1000 ppm (*
2
0…2000 ppmCO2
2
0...3000 ppmCO2
2
0...5000 ppmCO2
2
0…7000 ppmCO2
2
0…10000 ppmCO2
2
Place holder for future option, not available at this time
Probe installation
none
accessories
mounting clips, 2 pcs
(25245GMSP)
mounting flange
(GM45156SP)
Field check
none
adapter
(26150GM)
adapter
LED lights only
Display on cover
LED lights + backlit digital LCD display
Place holder for future option, not available at this time
probe in transmitter (wall model)
Wall/remote use
probe with 2 m cable (remote installation of probe)
probe with 10 m cable (remote installation of probe)
Alarm relay 1
setpoint not activated
custom setpoint for relay 1______ ppm / % CO2
PROBE
Vaisala CARBOCAP Carbon Dioxide Probe
1 Sampling method
diffusion
flow through
2 Measurement range of
0…1000 ppm CO2
the probe:
0…2000 ppm CO2
0...3000 ppm CO2
0...4000 ppm CO2
0...5000 ppm CO2 *
0…2 % CO2 *
3 Analog output
0...5V
selection **
0...2.5 V
4...20 mA
4 Digital output
RS-232
selection
RS-485 ***
5 Probe cable
none
probe cable (with M12 type female connector), 2 m
probe cable (with M12 type female connector), 6 m
probe cable (with M12 type female connector), 10 m
6 Measurement indicator
none
MI70 and accessories
MI70 indicator and interface cable, 2 m****
MI70 interface cable, 2 m
7 Calibration accessories
none
calibration adapter for diffusion model.
PC connection kit*****
calibration adapter for diffusion model and PC connection kit*****
8 Mounting accessories
none
mounting flange
9 Wiring accessories
none
junction box
10 Reserved for future use
11 Manual
no manual
English
2
TRANSMITTER UNIT
1
®
Examples of order codes with typical settings:
Transmitter with probe GM T 22 1 L 0 N 0 B 0 N 1 A 0 B
Accessories and Spare Parts:
Description:
In-soil adapter kit
Goretex membrane spare filter
plus cap for GMP221
Goretex membrane spare filter
plus cap for GMP222
Calibration Kit for interchangeable probes
Order Code:
211921GM
PRICE
$60
25378GMSP
$50
25879GMSP
GMK220
$50
$1,600
199
OMT355 Oxygen Transmitter
GM70 Hand-held Carbon Dioxide Meter
1
1
2
3
4
5
6
7
8
9
GM70
Vaisala CARBOCAP® Hand-held CO2 Meter
Indicator type
no indicator *
A
rechargeable with Euro AC-adapter
B
rechargeable with US AC-adapter
D
Indicator accessories
no indicator accessories
MI70LINK (software with RS232 cable)
analog output signal cable
(27168ZZ)
MI70LINK and analog output-signal cable
(MI70LINK+ 27168ZZ)
MI70LINK software with USB cable
(219687)
Accessories for
no indicator cables
adapter cable for transmitters)
transmitter checking
(GMA70)
diffusion (handle GMH70)
Sampling method
pump (GM70PUMP) + Nafion® membrane tubing (212807GM)
2
3
4
5
7
A
8
9
1
PRICE
$840
$840
0
1
2
3
4
$60
$35
$95
$90
with a flange adapter for in-line mounting
Ambient environment (range 2...25 %O2)
with a wall mounting bracket
0…2000 ppm CO2
C
0…3000 ppm CO2
D
0...5000 ppm CO2
E
0…7000 ppm CO2
F
0…10000 ppm CO2
G
0…2 % CO2
H
0...3 % CO2
J
0...5 % CO2
0...10 % CO2
0...20 % CO2
no accessories
field check adapter
K
3 Analog output range for oxygen
Define O2 special range from
8 Cable bushings
$70
9 In-line calibration option
QTY
$5,690
1
(216615)
PTFE filter with stainless steel net
2
$160
3
$290
O2 (0...5%)
A
O2 (0...10%)
B
O2 (0...15%)
C
O2 (0...20%)
D
O2 (0...25%)
E
O2 (0...100%)
K
__________%O 2
__________%O 2
to
X
4...20 mA
1
0...20 mA
2
3 mA or below
A
21 mA or higher
B
Fault state 3 mA can be chosen only if signal output is 4...20 mA
(can be reconfigured in the field)**
* select item A, only if the handle or pump with probe is ordered
$4,850
$5,200
7 Material of sample wetted O-rings
TOTAL
$4,850
(216653) B
$6,060
Setpoint: _____________ %O 2 (hysteresis 1%O2)
A
B
PRICE
E
PTFE filter non-compatible for 100% O2
NOTE:
$140
1 A
A
with a sample cell and a wall mounting bracket
No filter (sample cell installation)
6 Relay settings
(MI70CASE)
9 10 11 12 13
Sample cell (range 0... 100 %O2)*
(can be reconfigured in the field)**
0
1
8
C
5 Fault state current for analog output
A
7
D
(can be reconfigured in the field)**
0
1
(26150GM)
6
with a flange adapter for in-line mounting
4 Signal output
L
M
5
with a sample cell and a wall mounting bracket
Stainless steel net
SPECIAL:
4
Sample cell (range 0... 25 %O2)
$160
$900
$1,580
1
2
3
In-line (range 0... 100 %O2)*
2 Filter type
NOTE:
2
OMT355
In-line (range 0... 25 %O2)
(can be reconfigured in the field)
A
B
interchangeable probe:
Space holder for future option
Carrying case
no carrying case
carrying case
Manual
no manual
English manual
Vaisala SPECTRACAP® Oxygen Transmitter OMT355
1 Installation type
Measurement range of
Probe accessories
6
Relay opens ONLY when fault state occurs
1
Relay opens when O2 value decreases below setpoint
X
Relay opens when O2 value increases above setpoint
Y
EPDM
A
Kalrez
Cable gland M20x1.5
(cable diameter 8... 11 mm)
Conduit fitting NPT1/2
(inner threads)
Connector (8 pin M12 male) with 2m cable
Connector (8 pin M12 male) with 6m cable
Connector (8 pin M12 male) with 10m cable
no
Calibration gas inlet with check valve
B
(214728SP)
(217197)
(GMP343Z200SP)
(GMP343Z600SP)
(GMP343Z1000SP)
$980
1
2
3
4
5
$40
$50
$60
A
B
$640
1
10 Accessories
None
11 User's guide language
Serial interface cable for PC
no user's guide
12 Calibration
13 Maintenance and repair
English
ISO 9001 compliant factory calibration
Standard maintenance and repair
2
(19446ZZ)
$40
A
B
1
A
QTY
TOTAL VALUE
*Oxygen compatibility certification delivered with the 0…100%O2 range
Selections in bold are included in the purchase price.
TOTAL VALUE
**Requires a Serial Interface Cable and Terminal programme on PC
Items in italics are available at an additional cost.
Shaded options indicate most typical selections.
Example of an order code with typical settings:
GM70 D 4 A 1 M 1 A
Accessories and Spare Parts:
Description:
US Adapter
Battery NiMH 4.8 battery for MI70
Pump for GM70 Hand-held CO2 meter
Handle for GM70
Nafion® membrane tubing
200
Order Code:
MI70USADAPTER
26755
GM70PUMP
GMH70
212807GM
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
1
Example of order code with typical settings:
OMT355 A 2 B 1 A
1
A
1
A
1
B
1
A
B
PRICE
$60
$30
$1,050
$440
$200
Spare parts & accessories
Item
Stainless steel net
PTFE filter with EPDM O-ring
PTFE filter with Kalrez O-ring
Flange adapter with EPDM O-ring
Flange adapter with Kalrez O-ring
Wall mounting bracket
Sample/calibration cell with EPDM
Sample/calibration cell with Kalrez
Cable gland
Order code
216615
217055
217056
217053
217054
216653
217052
216619
214728SP
PRICE
$170
$125
$215
$165
$385
$120
$915
$1,220
$15
Item
Conduit fitting NPT1/2 (inner threads)
Connector for transmitter body
EPDM O-rings for sample cell
Kalrez O-rings for sample cell
Connection cable, 2 m
Connection cable, 6 m
Connection cable, 10 m
Junction box for 8-pole cable
Serial interface cable for PC
EPDM flange adapter gasket
Kalrez flange adapter gasket
Order code
217197
214806SP
217198
217199
GMP343Z200SP
GMP343Z600SP
GMP343Z1000SP
junctionbox-8
19446ZZ
216347
216833
PRICE
$35
$25
$60
$315
$40
$50
$60
$50
$40
$25
$40
201
OMT364 Nonincendive Oxygen Transmitter
Vaisala Pressure, Humidity and Temperature Transmitter PTU301 - Wall Mount
Vaisala SPECTRACAP® Oxygen Transmitter OMT364
1 Transmitter type
2 Installation type
OMT 360
OMT364
In-line (range 0... 25 %O2)
with a flange adapter for in-line mounting
Ambient environment (range 2...25 %O2)
with a wall mounting bracket
Sample cell (range 0... 25 %O2)
with a sample cell and a wall mounting bracket
No filter (sample cell installation)
3 Filter type
4
4
(216653)
Stainless steel net
1 A 1 A PRICE
A
$7,400
B
$7,400
C
(216615)
PTFE filter with stainless steel net
4 Analog output range for oxygen
(can be reconfigured in the field)
$8,240
1
2
$160
3
$290
O2 (0...5%)
A
O2 (0...10%)
B
O2 (0...15%)
C
O2 (0...20%)
D
O2 (0...25%)
SPECIAL:
Define O2 special range from
__________%O2
E
to __________%O2
X
Specifications are valid only for measurement range 0...25%O2
NOTE:
4...20 mA
5 Signal output
(can be reconfigured in the field)*
0...20 mA
6 Fault state current for analog output
(can be reconfigured in the field)*
1
2
3 mA or below
A
21 mA or higher
B
Fault state 3 mA can be chosen only if signal output is 4...20 mA
NOTE:
Relay opens ONLY when fault state occurs
7 Relay settings
Relay opens when O 2 value decreases below setpoint
Setpoint: _____________ %O2
Relay opens when O 2 value increases above setpoint
Setpoint: _____________ %O2
Define selected custom setpoint when required. Factory setpoint is 10%O2, hysteresis is 1%O2
8 Cable bushings
Cable gland M20x1.5**
(cable diameter 8... 11 mm)
Conduit fitting NPT1/2
(inner threads)
9 In-line calibration option
no
Calibration gas inlet with check valve
no user's guide
10 User's guide language
English
11 Approval
1
2
3
(214728SP)
(217197)
A
B
Special
1
2
$640
A
B
1
FM (USA, Canada)
A
12
1
13
14
A
QTY
*Requires a Serial Interface Cable and Terminal programme on PC. Reconfiguration should be done only in a safe area
Item
1
1 Vaisala Pressure, Humidity and Temperature Transmitter
PTU300
1
Transmitter type
PTU301
for wall mounting
1
2 Pressure range
500...1100 hPa
Class A / one sensor
500...1100 hPa
Class B / one sensor
500...1100 hPa
Class A / two sensors
500...1100 hPa
Class B / two sensors
50...1100 hPa
One sensor, class B only
50...1100 hPa
Two sensors, class B only
3 Wall mount probe
fixed
with short cable
Probe holder plate recommended in selection 17
4 Additional temperature probe
No probe
5 Display
No display
Graphic LCD with backlight
(HMT300PWS)
6 Power supply
10...35 VDC, 24 VAC
Galvanic isolation for outputs 10...35 VDC 24 VAC
(DCDC-1)
Universal AC power (100....240 VAC)
(POWER-1)
Universal AC power (100....240 VAC) + US power cord
(POWER-1 AND 215991)
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
Mandatory with two pressure sensors
7 Output signal
RS232C only, No Analog output
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
4... 20 mA
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 20 mA
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 1 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 5 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 10 V
Parameter and scaling for
No Analog output
analog output (Ch1, Ch2, Ch3)
RH
(0...100 %RH)
T
(range: see below)
Td (-20...100 °C)
(-4...+212 °F)
Tdf (-20...100 °C)
(-4...+212 °F)
a (0...600 g/m3)
(0...262 gr/ft3)
Tw (0...100 °C)
(+32...+212 °F)
x (0...500 g/kg d.a)
(0...3500 gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
pw (0…1000 hPa)
(0…14.5 psi)
pws (0…1000 hPa)
(0…14.5 psi)
dT (-10...+50 °C)
(14...+122 °F)
P
(pressure range: selection in item 2)
8
9
10
11 Analog output range
for temperature
Note: Select option A,
if T output is not required
14
TOTAL VALUE
Example of order code with typical settings:
OMT360 4
A
2
B
1
15
A
1
A
1
B
1
A
1
A
16
Spare parts & accessories
Item
Stainless steel net
PTFE filter with Kalrez O-ring
Flange adapter with Kalrez O-ring
Wall mounting bracket
Sample/calibration cell with Kalrez
Conduit fitting
Kalrez O-rings for sample cell/flange adaptor
Serial interface cable for PC
USB-RJ45 Serial Interface Cable
Cable gland
Kalrez Flange adaptor gasket
17
Order code
216615
217056
217054
216653
216619
217197
217199
19446ZZ
219685
214728SP
216833
PRICE
$170
$215
$385
$120
$1,220
$35
$315
$40 ………………..
$90 ………………..
$15
$40
3
A
4
0
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
0
A
1
2
3
4
5
6
18
19
Note! For safe area use only.
Note! For safe area use only.
20
21
22
23
$420
A
8
0
0
1
$320
A
B
C
D
K
$80
$200
$210
$60
0
1
2
3
4
5
$190
$190
$190
$190
$190
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
A
X
X
P
X
(-40...+140 °F)
(-4...+140 °F)
(+32...+140 °F)
special range :_______________________________
Standard
Metric
Non-metric
Mandatory with two pressure sensors or analog output
Optional module
No module
Relay output
(RELAY-1) -Not possible with power supply module
RS485 serial interface (galvanically isolated)
(RS485-1)
LAN (Ethernet) interface + 2 m cable (RJ45)
Not possible with Universal AC power
WLAN (Wireless Ethernet) interface + antenna
With short cable probe only
Data logger module
(214728SP)
Cable bushings
Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable)
Note: The universal AC power
(214780SP)
Conduit fitting NPT1/2"
must not be connected
8-pole connector with 5m cable
(212142)
through the 8-pole connector
8-pole counter connector with screw terminals
(212416)
or D9 adapter
D9-adapter
Only for RS232C, RS485 and DC supply
(19498)
Pressure fitting
Barbed fitting for 1/8" hose
Quick connector with shutoff valve for 1/8" hose
(19886, 25328 + 25329)
Transmitter installation
Normal mounting
Wall mounting plate
(214829)
Pole installation kit
(215108)
Pole installation kit with Rain Shield
(215109)
DIN rail kit
(215094)
Probe holder plate
Recommended with short cable probe (226252)
General purpose
HUMICAP180
Humidity sensor
Chemical purge
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180R
Chemical purge
HUMICAP180RC
(DRW010281SP)
Sensor protection
PPS plastic grid & stainless steel netting
(DRW010276SP)
PPS plastic grid
(HM47280SP)
Sintered stainless steel filter
HM47453SP
Stainless steel grid
Probe installation accessories
No probe installation accessories
User's Guide language
No manual
English
No
PC Accessories
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable
(215005)
(219685)
Service cable for PC, USB software driver
MI70LINK software for Windows® with USB service cable
(219916)
Calibration Certificate
ISO9001 compliant factory calibration / No Calibration Contract
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings:
PTU300 1 1 A 0 0 A 1 B C P
202
PRICE
$2,070
$200
$620
$420
Define quantity for Ch1:_______________ Ch2:______________
Define scale for
Ch1:_______________ Ch2:______________ Ch3:______________
Channel 1
Channel 2
Channel 3 only for pressure
No analog output
-40...+60 °C
-20...+60 °C
0...+60 °C
5
A
B
F
K
X
12 Output format
13 Output units
**Cable gland usable only in the USA according to FM approval
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
2
1
A
B
0
1
2
4
5
6
$180
$160
$260
$320
$350
A
B
C
D
E
$60
$60
$70
1
2
$40
A
B
C
D
E
F
$90
$100
$110
$90
$90
1
4
A
C
$60
$60
B
C
D
E
0
A
B
0
1
2
3
4
$40
$60
$90
$90
A
TOTAL
QTY
TOTAL VALUE
B
1
B
0
A
1
A
A
B
0
B
0
A
203
Vaisala Pressure, Humidity and Temperature Transmitter PTU303 - Outdoor Use
Item
1 Vaisala Pressure, Humidity and Temperature Transmitter
PTU300
for general use
Transmitter type
PTU303
2 Pressure range
500...1100 hPa
Class A / one sensor
500...1100 hPa
Class B / one sensor
500...1100 hPa
Class A / two sensors
500...1100 hPa
Class B / two sensors
50...1100 hPa
One sensor, class B only
50...1100 hPa
Two sensors, class B only
3 Probe cable length
2 m cable
5 m cable
10 m cable
4 Additional temperature probe
No probe
5 Display
No display
Graphic LCD with backlight
6 Power supply
10...35 VDC, 24 VAC
(HMT300PWS)
Galvanic isolation for outputs 10...35 VDC 24 VAC
(DCDC-1)
Universal AC power (100....240 VAC)
(POWER-1)
Universal AC power (100....240 VAC) + US power cord
(POWER-1 AND 215991)
Not IP65
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Mandatory with two pressure sensors
7 Output signal
RS232C only, No Analog output
4... 20 mA
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 20 mA
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 1 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 5 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 10 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
Parameter and scaling for
No Analog output
analog output (Ch1, Ch2, Ch3)
RH
(0...100 %RH)
T
(range: see below)
Td (-20...100 °C)
(-4...+212 °F)
Tdf (-20...100 °C)
(-4...+212 °F)
a (0...600 g/m3)
(0...262 gr/ft3)
Tw (0...100 °C)
(+32...+212 °F)
x (0...500 g/kg d.a)
(0...3500 gr/lb)
(-9.5...+652.6 Btu/lb)
h (-40...1500 kJ/kg)
pw (0…1000 hPa)
(0…14.5 psi)
pws (0…1000 hPa)
(0…14.5 psi)
dT (-10...+50 °C)
(14...+122 °F)
P
(pressure range: selection in item 2)
Vaisala Pressure, Humidity and Temperature Transmitter PTU307 - Warmed Probe
1
3
3
2
3
4
0
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
A
1
2
3
4
5
6
PRICE
$2,110
$200
$620
$420
$420
B
C
D
$150
$300
0
0
1
$320
A
B
C
D
K
$80
$200
$210
$60
0
1
2
3
4
5
$190
$190
$190
$190
$190
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
A
Item
1 Vaisala Pressure, Humidity and Temperature Transmitter
PTU300
Transmitter type
PTU307
for high humidity
500...1100 hPa
Class A / one sensor
2 Pressure range
500...1100 hPa
Class B / one sensor
500...1100 hPa
Class A / two sensors
500...1100 hPa
Class B / two sensors
50...1100 hPa
One sensor, class B only
50...1100 hPa
Two sensors, class B only
3 Probe cable length
2m cable
5 m cable
10 m cable
No probe
4 Additional temperature probe
2 m cable
5 m cable
10 m cable
No display
5 Display
Graphic LCD with backlight
10...35 VDC, 24 VAC
(HMT300PWS)
6 Power supply
Galvanic isolation for outputs 10...35 VDC 24 VAC
(DCDC-1)
Universal AC power (100....240 VAC)
(POWER-1)
Universal AC power (100....240 VAC) + US power cord
(POWER-1 AND 215991)
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Not IP65
Mandatory with two pressure sensors
RS232C only, No Analog output
7 Output signal
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
4... 20 mA
0... 20 mA
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 1 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 5 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 10 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
Parameter and scaling for
No Analog output
analog output (Ch1, Ch2, Ch3)
RH
(0...100 %RH)
T
(range: see below)
Td (-20...100 °C)
(-4...+212 °F)
Tdf (-20...100 °C)
(-4...+212 °F)
a (0...600 g/m3)
(0...262 gr/ft3)
Tw (0...100 °C)
(+32...+212 °F)
x (0...500 g/kg d.a)
(0...3500 gr/lb)
h (-40...1500 kJ/kg)
(-9.5...+652.6 Btu/lb)
pw (0…1000 hPa)
(0…14.5 psi)
pws (0…1000 hPa)
(0…14.5 psi)
dT (-10...+50 °C)
(14...+122 °F)
P
(pressure range: selection in item 2)
Define quantity for Ch1:_______________ Ch2:______________
Define scale for
Ch1:_______________ Ch2:______________ Ch3:______________
Channel 1
Channel 2
Channel 3 only for pressure
No analog output
(-40...+140 °F)
-40...+60 °C
(-4...+140 °F)
-20...+60 °C
(+32...+140 °F)
0...+60 °C
special range :_______________________________
Output format
Standard
Output units
Metric
Non-metric
Optional module
No module
Mandatory with two pressure sensors or analog output
(RELAY-1) -Not possible with power supply module
Relay output
(RS485-1)
RS485 serial interface (galvanically isolated)
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logger module
Cable bushings
Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable)
(214728SP)
Note: The universal AC power
Conduit fitting NPT1/2"
(214780SP)
8-pole connector with 5m cable
(212142)
must not be connected
through the 8-pole connector
8-pole counter connector with screw terminals
(212416)
Only for RS232C, RS485 and DC supply
or D9 adapter
D9-adapter
(19498)
Pressure fitting
Barbed fitting for 1/8" hose
(19886, 25328 + 25329)
Quick connector with shutoff valve for 1/8" hose
Transmitter installation
Normal mounting
(214829)
Wall mounting plate
(215108)
Pole installation kit
(215109)
Pole installation kit with Rain Shield
DIN rail kit
(215094)
Humidity sensor
General purpose
HUMICAP180
Chemical purge
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180R
Chemical purge
HUMICAP180RC
Sensor protection
PPS plastic grid & stainless steel netting
(DRW010281SP)
PPS plastic grid
(DRW010276SP)
Sintered stainless steel filter
(HM47280SP)
Stainless steel grid
(HM47453SP)
Probe installation
No kit
accessories
Duct Installation kit
(210697)
Cable Gland AGRO
(HMP247CG)
User's Guide language
No manual
English
No
PC Accessories
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable (215005)
(219685)
Service cable for PC, USB software driver
MI70LINK software for Windows® with USB service cable (219916)
Calibration Certificate
ISO9001 compliant factory calibration / No Calibration Contract
Selections in bold are included in the prices of the basic versions
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
X
X
14
15
16
17
18
19
20
21
22
23
8
9
10
11 Analog output range
for temperature
Note: Select option A,
if T output is not required
A
B
F
K
X
No analog output
-40...+60 °C
-20...+60 °C
0...+60 °C
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
A
1
2
3
4
5
6
PRICE
$3,100
$200
$620
$420
$420
E
F
G
$160
$370
0
1
2
3
$160
$180
$220
0
1
$320
A
B
C
D
K
$80
$200
$210
$60
0
1
2
3
4
5
$190
$190
$190
$190
$190
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
A
X
X
P
(-4...+140 °F)
(+32...+140 °F)
special range :_______________________________
Standard
Metric
Non-metric
Optional module
No module
Mandatory with two pressure sensors or analog output
Relay output
(RELAY-1) -Not possible with power supply module
RS485 serial interface (galvanically isolated)
(RS485-1)
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logger module
Cable bushings
Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable)
(214728SP)
Note: The universal AC power
Conduit fitting NPT1/2"
(214780SP)
8-pole connector with 5m cable
must not be connected
(212142)
8-pole counter connector with screw terminals
through the 8-pole connector
(212416)
D9-adapter
Only for RS232C, RS485 and DC supply
or D9 adapter
(19498)
Pressure fitting
Barbed fitting for 1/8" hose
Quick connector with shutoff valve for 1/8" hose
(19886, 25328 + 25329)
Transmitter installation
Normal mounting
Wall mounting plate
(214829)
Pole installation kit
(215108)
Pole installation kit with Rain Shield
(215109)
DIN rail kit
(215094)
Composite sensor
Humidity sensor
HUMICAP180C
Chemical purge
HUMICAP180C
General purpose and high chemical concentrations
HUMICAP180RC
Chemical purge
HUMICAP180RC
Sensor protection
PPS plastic grid & stainless steel netting
(DRW010281SP)
PPS plastic grid
(DRW010276SP)
Sintered stainless steel filter
(HM47280SP)
Stainless steel grid
(HM47453SP)
Probe installation
No kit
Duct Installation kit
accessories
(210697)
Cable Gland AGRO
(HMP247CG)
2 x Duct installation kits (RH+T probes)
(210697 + 215003)
User's Guide language
No manual
English
No
PC Accessories
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable
(215005)
(219685)
Service cable for PC, USB software driver
MI70LINK software for Windows® with USB service cable
(219916)
Calibration Certificate
ISO9001 compliant factory calibration / No Calibration Contract
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
A
B
F
K
X
12 Output format for serial interface
13 Output units
1
14
A
B
0
1
2
4
5
6
$180
$160
$260
$320
$350
A
B
C
D
E
$60
$60
$70
1
2
15
16
17
$40
A
B
C
D
E
$90
$100
$110
$90
18
19
1
4
A
C
$60
$60
B
C
D
E
20
21
0
1
2
$80
$60
22
A
B
0
1
2
3
4
$40
$60
$90
$90
A
TOTAL
QTY
TOTAL VALUE
23
Example of order code with typical settings:
PTU300 7 1 E 1 0 A 1 B C P
Vaisala Meteorological Installation Kit for PTU300 Transmitters
1 Support bar & shield for warmed Td probeNo support bar & shield for warmed Td probe
B
X
(-40...+140 °F)
Vaisala Meteorological Installation Kit
Example of order code with typical settings
PTU300 3 1 B 0 0 A 1 B C P
1
B
0
A
1
A
A
B
0
B
0
A
2
Additional Accessories: Description
Outdoor Solar Radiation Shield
3
Define quantity for Ch1:_______________ Ch2:______________
Define scale for
Ch1:_______________ Ch2:______________ Ch3:______________
Channel 1
Channel 2
Channel 3 only for pressure
X
8
9
10
11 Analog output range
for temperature
Note: Select option A,
if T output is not required
12
13
2
P
Special
Special
1
7
7
Order Code
DTR502B
PRICE
$310
3
4
5
Support bar, transmitter mounting plate & shield for warmed Td probe
No support bar or radiation shield
Support bar and radiation shield for
Support bar with DTR502 shield for T probe
additional T probe or for
Support bar with DTR13 shield for T probe
non-warmed RH or Td probe
Support bar with DTR502 shield for non-warmed RH or Td probe
Support bar with DTR13 shield for non-warmed RH or Td probe
No mounting plate
Support bar mounting plate
Pole mounting plate for support bar/bars
Additional transmitter mounting plate
No additional transmitter mounting plate
Transmitter mounting plate for support bar assembly
Transmitter mounting plate for pole assembly
Static Pressure Head
No Static Pressure Head
Static Pressure Head SPH10
Selections in bold are included in the prices of the basic versions
Selections in italic have an additional cost
Shaded sections indicate typical selections.
1
A
B
0
1
2
4
5
6
$180
$160
$260
$320
$350
A
B
C
D
E
$60
$60
$70
1
2
$40
A
B
C
D
E
$90
$100
$110
$90
3
4
B
C
B
C
D
E
0
1
2
6
$80
$60
$160
A
B
0
1
2
3
4
$40
$60
$90
$90
A
TOTAL
QTY
TOTAL VALUE
B
1
B
0
A
1
B
A
B
0
B
0
A
1 2 3 4 5
HMT330MIK
PRICE
0
1
$580
A
B
C
D
E
$580
$920
$580
$920
0
1
$120
A
B
C
0
1
TOTAL
QTY
TOTAL VALUE
$110
$110
$270
Example of order code with typical settings
HMT330MIK 1 B 1 A 0
204
205
Vaisala BAROCAP® Digital Barometer PTB330 - One Sensor
Vaisala Pressure and Temperature Transmitter PTU30T - Temperature only
Item
PTU300
1 VAISALA Pressure and Temperature Transmitte
Transmitter type
PTU30T
for pressure and temperature only
500...1100 hPa
Class A / one sensor
2 Pressure range
500...1100 hPa
Class B / one sensor
500...1100 hPa
Class A / two sensors
500...1100 hPa
Class B / two sensors
50...1100 hPa
One sensor, class B only
50...1100 hPa
Two sensors, class B only
2m cable
3 Temperature probe cable length
5 m cable
10 m cable
4 Additional temperature probe
No probe
No display
5 Display
Graphic LCD with backlight
10...35 VDC, 24 VAC
(HMT300PWS)
6 Power supply
Galvanic isolation for outputs 10...35 VDC 24 VAC
(DCDC-1)
Universal AC power (100....240 VAC)
(POWER-1)
Universal AC power (100....240 VAC) + US power cord
(POWER-1 AND 215991)
Not IP65
External US AC-adapter (for LAN/WLAN interface in USA and Canada)
Mandatory with two pressure sensors
RS232C only, No Analog output
7 Output signal
4... 20 mA
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 20 mA
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 1 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 5 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
0... 10 V
RS232C + Optional Analog output (Ch1, Ch2, Ch3)
Parameter and scaling for
No Analog output
analog output (Ch1, Ch2, Ch3)
T
(range: see below)
P
(pressure range: selection in item 2)
Special
8
9
10
11 Analog output range
for temperature
Note: Select option A,
if T output is not required
Define scale for
No analog output
-40...+60 °C
-20...+60 °C
0...+60 °C
1
T
T
2
3
4
0
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1
0 A 0
1
2
3
4
5
6
$620
$420
15
16
17
18
19
20
21
22
23
2
3
$20
$60
0
Ch1:_______________ Ch2:______________ Ch3:______________
Channel 1
Channel 2
Channel 3 only for pressure
4
0
1
$320
A
B
C
D
K
$80
$200
$210
$60
0
1
2
3
4
5
$190
$190
$190
$190
$190
A
C
A
C
A
X
X
X
5
6
7
8
P
(-40...+140 °F)
(-4...+140 °F)
(+32...+140 °F)
special range :_______________________________
Standard
Metric
Non-metric
Optional module
No module
Mandatory with two pressure sensors or analog output
(RELAY-1) - Not possible with power supply module
Relay output
(RS485-1)
RS485 serial interface (galvanically isolated)
LAN (Ethernet) interface + 2 m cable (RJ45)
WLAN (Wireless Ethernet) interface + antenna
Data logger module
Cable bushings
Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable)
(214728SP)
Note: The universal AC power
Conduit fitting NPT1/2"
(214780SP)
8-pole connector with 5m cable
(212142)
must not be connected
through the 8-pole connector
8-pole counter connector with screw terminals
(212416)
Only for RS232C, RS485 and DC supply
or D9 adapter
D9-adapter
(19498)
Pressure fitting
Barbed fitting for 1/8" hose
(19886, 25328 + 25329)
Quick connector with shutoff valve for 1/8" hose
Transmitter installation
Normal mounting
(214829)
Wall mounting plate
(215108)
Pole installation kit
(215109)
Pole installation kit with Rain Shield
DIN rail kit
(215094)
Humidity sensor
No humidity sensor
Sensor protection
No sensor protection
Probe installation accessories
No probe installation accessories
User's Guide language
No manual
English
No
PC Accessories
Service cable for PC
(19446ZZ)
MI70LINK software for Windows® with RS232 service cable (215005)
(219685)
Service cable for PC, USB software driver
MI70LINK software for Windows® with USB service cable (219916)
Calibration Certificate
ISO9001 compliant factory calibration / No Calibration Contract
Selections in bold are included in the prices of the basic versions
Selections in italic are available at an extra price.
Shaded sections indicate typical selections.
Example of order code with typical settings
PTU300 T 1 H 0 0 A 1 A C P
206
1
$420
H
J
K
9
A
B
F
K
X
12 Output format for serial interface
13 Output units
14
PRICE
$2,020
$200
10
1
11
A
B
0
1
2
4
5
6
$180
$160
$260
$320
$350
A
B
C
D
E
$60
$60
$70
1
2
12
13
14
1
2
Digital Barometer with One Pressure Sensor
PTB330
Accuracy Class
Class A
A
Class B
B
Display
No display
0
Graphical LCD with backlight
1
Power Supply
10...35 VDC
10...35 VDC with external power on/off triggering
10...35 VDC, 24 VAC, galvanical isolation for outputs
(DCDC-1)
Internal AC-power (110....240 VAC)
(POWER-1)
Internal AC-power (110....240 VAC) + US power cord
(216017)
External US AC-adapter (Not IP65)
(MI70USADAPTER)
Signal Output
RS-232 only, no analog output
Analog output
4...20 mA
0...20 mA
0...1 V
0...5 V
0...10 V
RS-485
(RS485-1)
Pressure range
500...1100 hPa
50...1100 hPa
Class B only
Optional Module (slot 3)
No module
(RELAY-1)
Relay module (Select A with internal AC power)
Optional Module (slot 4)
No module
Customer Connection
Cable bushing for 10...14 mm cable
Conduit fitting NPT 1/2"
8-pole M12 connector with 5 m cable
(212142)
8-pole M12 connector with screw terminals
(212416)
D9 connector
Not IP65
Pressure Fitting
Barbed fitting 1/8"
Quick connector 1/8"
(19886, 25328 + 25329)
Optional Connection
None
Select A only with external AC adapter
Plugged
Select C or D with internal AC power
Cable bushing for 10...14 mm cable
Select C or D with internal AC power
Conduit fitting NPT 1/2"
Installation
Normal mounting
Adapter plate (for replacing PTB220)
(214829)
Pole installation kit
(215108)
Pole installation kit with Rain Shield
(215109)
DIN rail kit
(215094)
Calibration
ISO 9001 compliant factory calibration / No calibration contract
(Separate order form required)
ISO/IEC 17025 Accredited calibration
Service contract
No Service Contract
User's Guide language
No User's Guide
English
3
4
5
6
7
A
8
9
10 11 12 13 14
PRICE
$1,790
$1,580
$320
A
B
C
D
F
K
$80
$200
$210
$60
A
C
D
E
F
G
K
$160
$160
$160
$160
$160
$160
H
J
A
B
$180
A
C
D
E
F
P
$60
$60
$70
E
L
$40
A
B
C
D
0
1
2
3
4
$90
$100
$110
$90
A
B
Order Guide
0
A
B
TOTAL VALUE
QTY
Items in bold are included in the basic price.
$40
A
B
C
D
E
$90
$100
$110
$90
TOTAL VALUE
Selections in italic are available at an additional cost.
Shaded sections indicate typical selections.
Example of order code with typical settings:
PTB330 - One Sensor
A
0
A
A
H
A
A
C
E
B
0
A
0
B
0
A
0
A
B
0
1
2
3
4
$40
$60
$90
$90
Accessories to be ordered separately. Description:
Interface cables
Serial Interface Cable
Software Interface Kit (MI70LINK + serial interface cable)
USB-RJ45 Serial Connection Cable
MI70LINK software for Windows® + USB-RJ45 Serial Connection Cable
Order Code:
19446ZZ
215005
219685
219916
PRICE
$40
$60
$90
$90
A
TOTAL
QTY
TOTAL VALUE
B
1
B
0
A
1
A
0
A
0
B
0
A
207
Vaisala BAROCAP® Digital Barometer PTB330 - Three sensors
Vaisala BAROCAP® Digital Barometer PTB330 - Two Sensors
1
2
3
4
5
6
7
A
Digital Barometer with Two Pressure Sensors, Single Redundancy
PTB330
Class A
A
1 Accuracy Class
Class B
B
No display
0
2 Display
Graphical LCD with backlight
1
10...35 VDC
3 Power Supply
A
10...35 VDC with external power on/off triggering
B
10...35 VDC, 24 VAC, galvanical isolation for outputs
C
(DCDC-1)
External US AC-adapter (Not IP65)
K
(MI70USADAPTER)
A
4 Signal Output
RS-232 only, no analog output
Analog output
4...20 mA
C
0...20 mA
D
0...1 V
E
0...5 V
F
0...10 V
G
RS-485
K
(RS485-1)
500...1100 hPa
H H
5-6 Pressure Range
(Same range for both sensors) 50...1100 hPa
Class B only
J J
A
7 Optional Module (slot 4)
No module
8 Customer Connection
Cable bushing for 10...14 mm cable
Conduit fitting NPT 1/2"
8-pole M12 connector with 5 m cable
(212142)
8-pole M12 connector with screw terminals
(212416)
D9 connector
Not IP65
Barbed fitting 1/8", differential measurement
Select E for optional connection (10)
9 Pressure Fitting
Barbed fitting 1/8"
Quick connector 1/8", differential measurement
Select L for optional connection (10) (19886, 25328 + 25329)
Quick connector 1/8"
(19886, 25328 + 25329)
Select A only with external AC adapter
None
10 Optional Connection
Plugged
Cable bushing for 10...14 mm cable
Conduit fitting NPT 1/2"
Barbed fitting 1/8", for differential measurement
Not available with AC-adapter
Quick connector 1/8", for differential measurement
Not available with AC-adapter (19886, 25328 + 25329)
Normal mounting
11 Installation
Adapter plate (for replacing PTB220)
(214829)
Pole installation kit
(215108)
Pole installation kit with Rain Shield
(215109)
DIN rail kit
(215094)
ISO 9001 compliant factory calibration / No calibration contract
12 Calibration
ISO/IEC 17025 Accredited calibration
(Separate order form required)
13 Service contract
No Service Contract
No User's Guide
14 User's Guide language
English
8
9
10 11 12 13 14
PRICE
$2,250
$2,040
$320
$80
$60
$160
$160
$160
$160
$160
$160
C
D
E
F
P
$60
$60
$70
E
F
L
M
$40
$40
A
B
C
D
E
L
$40
0
1
2
3
4
$90
$100
$110
$90
A
B
A
H
H
A
C
F
B
0
Accessories to be ordered separately Definition:
Interface cables
Order Code:
Serial Interface Cable
19446ZZ
215005
Software Interface Kit (MI70LINK + serial interface cable)
219685
USB-RJ45 Serial Connection Cable
219916
MI70LINK software for Windows® + USB-RJ45 Serial Connection Cable
208
A
4
5
6
7
8
9
10 11 12 13 14
PRICE
$2,710
$2,500
$320
A
B
C
K
$80
$60
A
C
D
E
F
G
K
$160
$160
$160
$160
$160
$160
H
J
H
J
H
J
C
D
E
F
P
$60
$60
$70
G
N
$40
A
B
C
D
0
1
2
3
4
0
$90
$100
$110
$90
A
B
Order Guide
0
A
B
TOTAL
QTY
TOTAL VALUE
Items in bold are included in the basic price.
Selections in italic are available at an additional cost.
A
B
TOTAL
QTY
TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
A
0
A
PTB330 - Three Sensors
Shaded sections indicate typical selections.
Example of order code with typical settings:
PTB330 - Two Sensors
A
0
A
3
Order Guide
0
Items in bold are included in the basic price.
Selections in italic are available at an additional cost.
1
2
Digital Barometer with Three Pressure Sensors, Double Redundancy
PTB330 - 3 Sensors
Class A
A
1 Accuracy Class
Class B
B
No display
0
2 Display
Graphical LCD with backlight
1
10...35 VDC
3 Power Supply
10...35 VDC with external power on/off triggering
10...35 VDC, 24 VAC, galvanical isolation for outputs
(DCDC-1)
External US AC-adapter (Not IP65)
(MI70USADAPTER)
RS-232 only, no analog output
4 Signal Output
Analog output
4...20 mA
0...20 mA
0...1 V
0...5 V
0...10 V
RS-485
(RS485-1)
500...1100 hPa
5-7 Pressure Range
(Same range for all sensors) 50...1100 hPa
Class B only
Cable bushing for 10...14 mm cable
8 Customer Connection
Conduit fitting NPT 1/2"
8-pole M12 connector with 5 m cable
(212142)
8-pole M12 connector with screw terminals
(212416)
D9 connector
Not IP65
Barbed fitting 1/8"
9 Pressure Fitting
Quick connector 1/8"
(19886, 25328 + 25329)
Select A only with external AC adapter
None
10 Optional Connection
Plugged
Cable bushing for 10...14 mm cable
Conduit fitting NPT 1/2"
Normal mounting
11 Installation
Adapter plate (for replacing PTB220)
(214829)
Pole installation kit
(215108)
Pole installation kit with Rain Shield
(215109)
DIN rail kit
(215094)
ISO 9001 compliant factory calibration / No calibration contract
12 Calibration
(Separate order form required)
ISO/IEC 17025 Accredited calibration
13 Service contract
No Service Contract
No User's Guide
14 User's Guide language
English
B
PRICE
$40
$60
$90
$90
A
H
H
H
C
G
Accessories to be ordered separately. Definitions:
Interface cables
Serial Interface Cable
Software Interface Kit (MI70LINK + serial interface cable)
USB-RJ45 Serial Connection Cable
MI70LINK software for Windows® + USB-RJ45 Serial Connection Cable
B
0
A
Order Code:
19446ZZ
215005
219685
219916
0
B
PRICE
$40
$60
$90
$90
209
www.vaisala.com
GMW116 Carbon Dioxide and Temperature
Transmitter for Ventilation Control
The Vaisala CARBOCAP® Carbon Dioxide and Temperature Transmitter GMW116.
Features/Benefits
▪
▪
▪
Compact dual-parameter
transmitter: measures both
CO2 and T
Incorporates Vaisala
CARBOCAP®, the silicon based
NDIR sensor with unique
internal referencing
Advanced, single-beam, dual
wavelength measurement with
no moving parts
▪
▪
Excellent long-term stability
▪
No need for temperature
compensation
Ideal for ventilation control in
all types of occupied spaces
including those with aroundthe-clock occupancy
The Vaisala CARBOCAP® Carbon
Dioxide and Temperature Transmitter
GMW116 is the compact-size
transmitter that measures both
carbon dioxide and temperature. The
sensor is accurate and durable and it
has an excellent long-term stability,
which decreases maintenance.
The excellent performance of the
Vaisala CARBOCAP® sensors results
largely from the stable reference
provided by the electrically tunable
Fabry-Perot Interferometer (FPI).
In buildings with around-theclock occupancy (e.g. hospitals,
work-places, residential buildings,
retirement homes), the assumed
background CO2 level reference
is simply not applicable. The true
internal reference measurement of
Vaisala CARBOCAP® CO2 transmitters
provides years of stable CO2
measurements.
The GMW116 Transmitter is designed
especially for demand controlled
ventilation applications with CO2
measurement range of
0 … 2000 ppm and temperature range
of 0 ... +50 °C.
With GMW116 there is no need for
temperature compensation. The ideal
gas temperature behaviour is taken
into account automatically.
Technical data
Performance
Dimensions
CO2-measurement range
Temperature measurement range
Accuracy (including repeatability, nonlinearity and calibration uncertainty)
Long-term stability
Response time T90
Temperature dependence
Pressure dependence, typical
Temperature measurement accuracy
Warm-up time
Product lifetime
0 ... 2000 ppm
0 ... +50 °C
± (2 % of range + 2 % of
reading
± 5 % of range/5 years
1 min
compensated
+0.15 % of reading/hPa
± 0.7 °C at 25 °
1 min, 10 min for full.
specification
> 10 years
Operating environment
Temperature
0 ... +50 °C
Humidity
0 ... 85 % RH
Pressure
700 ... 1200 hPa
Electromagnectic compatibility
Complies with EMS standard EN61326-1, Generic Environment
Inputs and outputs
Operating voltage
Power consumption
Outputs
24 V (±20 %) AC/DC
<2 W
0 … 10 V
Housing
Material
Weight
Cover and base colour
Fire resistance
Ingress protection
ABS/PC blend plastics
120 g
white RAL 9003
UL94 V0
IP30
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B210872EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
PTB210 Series Digital Barometers
PTB210 Series Digital Barometers
Analog Output
Serial Output
1
1
Vaisala BAROCAP® Barometric Pressure Transmitter - Analog Output
Pressure range
500…1100 hPa
2
Output options
3
Cable length
4
Manual language
2
3
4
PTB210 C
1
PRICE
3
$1,020
800…1060 hPa
4
$1,020
600…1060 hPa
5
$1,020
900…1100 hPa
6
$1,020
0…5 VDC
C
0…2.5 VDC
D
1.0 m
1
2.0 m
2
$15
®
1
Vaisala BAROCAP Barometric Pressure Transmitter
Accuracy class
Class A (only for 500…1100 hPa range)
Class B
2
Pressure range
3
Output options
4
Cable length
2
3
4
5
PTB210
PRICE
A
$1,470
B
$1,230
500…1100 hPa
(Class A or B)
1
50…1100 hPa
(Class B only)
2
Only RS 232C serial communication
A
RS 485 (and RS 232C) serial communication (*
B
TTL level (and RS 232C) serial communication (*
T
$160
$160
1.0 m
1
3.0 m
3
$20
2.0 m
2
5.0 m
4
$40
3.0 m
3
$20
10.0 m
5
$80
5.0 m
4
$40
10.0 m
5
no manual
A
English
M
5
TOTAL
Manual language
no manual
Selections in italic are available at an additional cost.
$80
A
English
B
QTY
Items in bold are included in the basic price.
$15
TOTAL
QTY
(* The two output protocols cannot be used simultaneously.
TOTAL VALUE
TOTAL VALUE
Shaded sections indicate typical selections.
Items in bold are included in the basic price.
Selections in italic are available at an additional cost.
Example of an order code with typical settings:
PTB210 C 3 C 1 M
Shaded sections indicate typical selections.
Example of an order code with typical settings:
Accessories and Spare Parts:
Description:
Order Code:
Static Pressure head
Static Pressure head, heated
SPH10
SPH20
PRICE
PTB210 B
Accessories and Spare Parts:
210
1
A
1
B
$270
$820
Description:
Order Code:
Static Pressure head
Static Pressure head, heated
SPH10
SPH20
PRICE
$270
$820
211
PTB110 Barometer
PTB330TS Barometric Pressure Transfer Standard
1 2 3 4 5
1
2
3
4
5
Barometer
Pressure range
PTB110
500…1100 hPa
1
600...1100 hPa
2
3
800...1100 hPa
600...1060 hPa
4
5
800…1060 hPa
0...5 Vdc
A
Output options
B
0...2.5 Vdc
Frequency output
F
Installation
Standard installation
0
DIN rail installation kit
1
Pressure fitting
Standard
A
Quick connector with shut-off valve for 1/8" hose
B
No user's guide
A
User's guide
English
B
TOTAL
QTY
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
TOTAL VALUE
Price
Vaisala BAROCAP® Barometric Pressure Transfer Standard
$950
PTB330TS
$3,200
Please, select below a configuration code for the PTB330 Barometer on the first row, for the MI70 Indicator on the second row
and optionally for the HMP155 Probe on the third row.
PTB330 Digital Barometer for PTB330TS
$10
$40
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Example of order code with typical settings:
PTB110 1 A 0 A B
1
PTB330 A
Vaisala BAROCAP® Digital Barometer
Class A
A
Accuracy Class
Display
No display
Power Supply
10...35 VDC
Signal Output
RS-232 only, no analog output
Pressure Range
Barometer module
500...1100 hPa
2nd Barometer module
No module
Barometer module
500...1100 hPa
3rd Barometer module
No module
Barometer module
500...1100 hPa
Customer Connection
8-pole M12 connector
Barbed fitting 1/8", one barometer module
Pressure Fitting
Choose according
Barbed fitting 1/8", two barometer modules
to selection
Barbed fitting 1/8", three barometer modules
made above
Optional Connection
Plugged
Installation
PTB330TS in weatherproof hard case
Calibration
ISO 9001 compliant factory calibration / No calibration contract
See separate order form
Special calibration for PTB330TS
No Service Contract
Service contract
User's Guide language
PTB330TS Guide in English
Selections in bold are included in the price of the basic version
Selections in italic are available at an extra cost
2
0
3
A
4
A
5
H
6
7
8
F
9
10 11 12 13 14
B 5
0 1
Price
0
A
A
H
A
H
$460
A
H
$460
F
E
F
G
B
5
A
X
0
1
Example of order code with typical settings:
A 0 A A H
PTB330
H
H
F
G
B
5
A
0
1
2
3
MI70 Hand-Held Indicator for PTB330TS
1
Vaisala Hand-held Indicator
1 Charger type
2 Installation
3 Accessories
MI70
Price
4
Euro AC-adapter
US AC-adapter
PTB330TS
none
MI70LINK software with RS232 cable
MI70LINK software with USB cable
B
D
4
0
1
4
$60
$90
Total value
Selections in bold are included in the price of the basic version
Selections in italic are available at an extra cost
Spare parts:
MI70 connection cable to HMT330, MMT330, DMT340, HMT100, PTB330
MI70 battery
MI70
Example of order code with typical settings:
D
4
4
9
10 11 12 13 14 15
Price
A
0
$640
$60
$30
Item: 211339
Item: 26755
OPTIONAL (with additional price):
HMP155 Humidity and Temperature Probe for PTB330TS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Vaisala HUMICAP® Humidity and Temperature Probe
RS485 serial output
Probe type
RS485 serial output
Signal output selection
Analog output signal for CH1
None
Analog output signal for CH2
None
Units
Metric
Non-metric
General purpose
Humidity sensor type
Composite sensor
Heating options
None
Chemical purge
None
Manual purge with MI70 (only with composite sensor)
Sensor protection
Sintered Teflon filter
Probe cable length
No cable (no counter connector)
None (if probe type D selected, please select option A)
Additional Temperature probe
Additional T-probe with 2m cable
Calibration
At room temperature
MI70 connection cable
PC-Accessories
Installation
PTB330TS
(For production use only)
1
2
3
4
HMP155 E
E
1
A
A
5
6
7
8
A
1
C
4
A
1
A
A
1
2
HUMICAP180R
HUMICAP180RC
1
2
$60
A
0
4
A
0
A
B
$160
1
Item:221801
C
$60
4
A
Total value
Selections in bold are included in the price of the basic version
Selections in italic are available at an extra cost
212
Example of order code with typical settings:
HMP155
E 1 A A 2 1
A
0
A
0
A
1
C
4
A
213
WMT52 Ultrasonic Wind Speed and Direction Sensor
WXT520 Weather Transmitter
1
WMT52
Vaisala WINDCAP® Ultrasonic Wind Sensor
Wind speed and direction
A
1 Measurement parameters
SDI-12 v 1.3, 1200 baud, 7,E,1
2 Communication interface
3
RS-232, Standard ASCII auto, 19200 baud,8,N,1
RS-485, Standard ASCII polled, 19200 baud, 8,N,1
RS-422, Standard ASCII auto, 19200 baud, 8,N,1
RS-422 NMEA 0183 v3.0, 4800 baud, 8,N,1
USB/RS-232, 1.4 m USB cable, ASCII auto, 19200 baud,8,N,1 (220782)
USB/RS-485, 1.4 m USB cable, ASCII polled, 19200 baud, 8,N,1 (220782)
None
4 Enhancements
Heating
No connector, bushing & grounding accessories
5 Connector
6 Cable
7 Installation accessories
8 Supporting software
9 Manual
10 Packing
2
3
4
5
6
7
8
9
1
10
PRICE
$1,080
A
A
A
A
A
A
A
A
B
C
D
E
F
G
$110
$110
0
1
8-pin M12 male connector and bushing & grounding accessories
No Cable
Shielded 2 meters long 8-pin M12 cable (222287)
Shielded 10 meters long 8-pin M12 cable (222288)
Shielded 40 meters long 14-pin cable, open end wires (217020)
Shielded 10 meters long 8-pin M12 cable, connectors on both ends (215952)
None
Mounting kit
improves classification from IP65 to IP66 (212792)
(212793)
Bird spike
Mounting kit and Bird spike
improves classification from IP65 to IP66 (212792 + 212793)
None
Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable
A
B
A
B
C
D
E
Wsd+RH+T+P+R
SDI-12 v 1.3, 1200 baud, 7,E,1
0
1
2
3
RS-232, Standard ASCII auto, 19200 baud,8,N,1
RS-485, Standard ASCII polled, 19200 baud, 8,N,1
RS-422, Standard ASCII auto, 19200 baud, 8,N,1
RS-422 NMEA 0183 v3.0, 4800 baud, 8,N,1
USB/RS-232, 1.4 m USB cable, ASCII auto, 19200 baud,8,N,1 (220782)
USB/RS-485, 1.4 m USB cable, ASCII polled, 19200 baud, 8,N,1 (220782)
None
No connector, bushing & grounding accessories
8-pin M12 male connector and bushing & grounding accessories
$55
6 Cable
No Cable
Shielded 2 mete rs long 8-pin M12 cable (222287)
$90
$120
$200
0
1
9 Manual language
$150
10 Packing
A
B
Standard
8 Supporting software
4
5
6
7
9
A
B
C
D
E
A
A
F
G
Price
$110
$110
0
$90
A
B
$55
A
Shielded 10 meters long 8-pin M12 cable (222288)
Shielded 40 meters long 14-pin cable, open end wires (217020)
Shielded 10 meters long 8-pin M12 cable, connectors on both ends (215952)
None
Mounting kit
improves classification from IP65 to IP66 (212792)
(212793)
Bird spike
improves classification from IP65 to IP66 (212792+ 212793)
Mounting kit and Bird spike
None
B
C
D
E
$100
$160
$300
$210
0
1
2
3
$90
$120
$200
0
Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable
No manual
English
Standard
QTY
TOTAL VALUE
10
0
$2,150
A
A
A
A
A
1
$150
A
B
0
TOTAL
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
0
TOTAL
8
1
5 Connector
7 Installation accessories
3
A
$90
$100
$160
$300
$210
No manual
English
Example of order code with typical settings:
WMT52
A
A
A
0
A
A
1
QTY
TOTAL VALUE
Example of order code with typical settings:
WXT520
A
A
A
0
A
A
1
1
B
0
WXT520 Spare parts & Accessories
1
B
0
220614
218817SP
WXTBOTTOMSP
WXT52 Spare parts & Accessories
Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable
WMT52 Bottom assembly (with BIF card, M12 connector, short screws. O-rings)
$180
$200
WMT50/52 Spare parts & Accessories
220782
222287
222288
217020
215952
222109
212792
WSP150
WSP152
212793
4 Enhancements
2
WXT520
Heating for wind and rain measurements
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
220614
WMTBOTTOMSP
Weather Transmitter
1 Measurement parameters
2 Communication interface
3
USB RS-232/485, 1.4 meters USB / M12 cable
Shielded 2 meters long 8-pin M12 cable
Shielded 10meters long 8-pin M12 cable
Shielded 40 meters long 14-pin cable, open end wires
10 meters long 8-pin M12 cable, connectors on both ends
Bushing & grounding accessory kit
Mounting kit (improves classification from IP65 to IP66)
Surge protector, no connectors
Surge protector for host PC (e.g. USB connection) inc. M12 connectors. Suitable with 220782 and 215952.
Bird kit
$140
$140
$210
$400
$270
$30
$120
$300
$350
$140
Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable
WXT520 Radiation shield set
WXT520 Bottom assembly (with BIF card, M12 connector, screws w. O-rings)
$180
$175
$200
WXT510/520 Spare parts & Accessories
220782
222287
222288
217020
215952
WXTPTUSP
222109
212792
WSP150
WSP152
212793
USB RS-232/485, 1.4 meters USB / M12 cable
Shielded 2 meters long 8-pin M12 cable
Shielded 10meters long 8-pin M12 cable
Shielded 40 meters long 14-pin cable, open end wires
10 meters long 8-pin M12 cable, connectors on both ends
WXT PTU module
Bushing & grounding accessory kit
Mounting kit (improves classification from IP65 to IP66)
Surge protector, no connectors
Surge protector for host PC (e.g. USB connection) inc. M12 connectors. Suitable with 220782 and 215952.
Bird kit
$140
$140
$210
$400
$270
$210
$30
$120
$300
$350
$140
WXT510 Spare parts & Accessories
215194
221523
Service Pack 1: Vaisala Configuration Tool, Weather Measurements (software and RS-232 WXT510 service cable)
M8 adapter to WXT510 Service connector (use with Service pack 2)
$90
$60
WMT50 Spare parts & Accessories
215194
221523
214
Service Pack 1: Vaisala Configuration Tool, Weather Measurements (software and RS-232 WXT510 service cable)
M8 adapter to WXT510 Service connector (use with Service pack 2)
$90
$60
215
Non-configurable Instrument price list
HUMIDITY AND TEMPERATURE INSTRUMENTS
WA15 Wind Set
1
3
PRICE
A
B
C
D
Accessories
Sensors
Vaisala Wind Measurement Set
WA15
no sensors
wind speed sensor WAA151 only
wind direction sensor WAV151 only
wind speed and direction sensors WAA151 and WAV151
2
Crossarm or transmitter no crossarm or wind transmitter
(signal pass-through)
and cable
crossarm with termination box WAC151
crossarm with termination box WAC151, 16-lead signal cable
crossarm with termination box WAC151, 6-lead power cable
crossarm with termination box WAC151, 16-lead signal and 6-lead power cable
(current loop output)
crossarm and analog transmitter WAT12
crossarm and analog transmitter WAT12, 6-lead cable for signal and power
(WAC155)
Crossarm and serial RS-485 transmitter WAC155
(WAC155B)
Serial RS-485 transmitter WAC155CB card only
3
Power supply
no power supply
power supply WHP151
1
2
$550
$590
$1,130
1
2
3
4
5
6
7
8
9
$440
$560
$560
$650
$730
$810
$790
$260
A
B
TOTAL
QTY
TOTAL VALUE
Selections in bold text are included in the price of basic version.
$580
Portables:
HM34
Pocket-size relative humidity and temperature meter……………………………………..
$535
Duct and Wall Mount:
HMD60Y
Humidity and temperature 2-wire transmitter for duct mounting, 4 to 20 mA outputs….
$525
HMD60U
Humidity transmitter for duct mounting; same as HMD60Y but humidity only………….
$420
HMW60Y
Humidity and temperature 2-wire transmitter for wall mounting, 4 to 20 mA outputs….
$480
HMW60U
Humidity transmitter for wall mounting; same as HMW 60Y but humidity only…………
$360
HMD70Y
Humidity and temperature 3-wire transmitter for duct mounting with voltage outputs…
$525
HMD70U
Humidity transmitter for duct mounting; same as HMD70Y, but humidity only…………
$420
HMW70Y
Humidity and temperature transmitter for wall mounting with voltage outputs………….
$480
HMW70U
Humidity transmitter for wall mounting; same as HMW70Y but humidity only………….
$360
Selections in italic are available at extra cost.
Shaded sections indicate typical selections.
Temperature-Only:
Example of order code with typical settings:
WA15 D
Accessories and Spare Parts: Description
Set of bearings and gasket
Cup assembly
Thermostat Switch Option (not included in AWAT12 if ordered separately)
Connector WAA151, WAA252
Connector WAV151, WAV252
Outdoor Signal Cable for WA-sensor, 10m (16-lead)
Outdoor Heating Power Cable, 10m (6-lead)
Vaisala Surge Protector
Order Code
16644WA
7150WA
16923WA
1394
1395
ZZ45048
ZZ45049
WSP150
5
B
PRICE
$45
$60
$70
$35
$35
$125
$85
$300
HMD60T
Temperature two-wire transmitter for duct mounting, 4 to 20mA outputs……………….
$410
HMW60T
Temperature two-wire transmitter for wall mounting, 4 to 20 mA outputs……………….
$360
HMD70T
Temperature three-wire transmitter for duct mounting with voltage outputs……………
$440
HMW70T
Temperature three-wire transmitter for wall mounting with voltage outputs…………….
$360
HMD60YO
Humidity and temperature 2-wire transmitter for use outdoors 4 to 20 mA outputs. …..
$760
HMD60UO
Humidity 2-wire transmitter for use outdoors; same as HMD60YO but humidity only…
$640
HMD70YO
Humidity and temperature 3-wire transmitter for use outdoors with voltage outputs….
$840
HMD70UO
Humidity 3-wire transmitter for use outdoors. Same as HMD70YO, but humidity only..
$670
HMD40Y
Humidity and temperature 2-wire transmitter for duct mounting, 4 to 20 mA outputs….
$260
HMD40U
Humidity transmitter for duct mounting: same as HMD40Y, but humidity only…………
$190
HMW40Y
Humidity and temperature 2-wire transmitter for wall mounting, 4 to 20 mA outputs….
$240
HMW40U
Humidity transmitter for wall mounting; same as HMW40Y, but humidity only…………
$180
HMD50Y
Humidity and temperature 3-wire transmitter for duct mounting with voltage outputs. ..
$260
HMD50U
Humidity transmitter for duct mounting; same as HMD50Y, but humidity only…………
$190
HMW50Y
Humidity and temperature 3-wire transmitter for wall mounting with voltage outputs….
$240
HMW50U
Humidity transmitter for wall mounting; same as HMW 50Y, but humidity only………...
$180
Outdoor Use:
Calibration-Free:
SOLAR RADIATION AND PRECIPITATION SHIELDS
216
DTR503A
Solar radiation and precipitation shield, 12 plate…………………………………………..
$310
DTR502B
Solar radiation and precipitation shield, 9 plate…………………………………………….
$310
217
Vaisala Contact Information
HMT300TMK for Power Turbine
Complete Solutions Consists of:
Transmitter: HMT3307S0C021XXAA200F0EAABAA1
X = -49 to 167°F dewpoint
Installation Kit: HMT300TMK1B1
EUROPE
Total Price: $3985
CARBON DIOXIDE (CO2) INSTRUMENTS
GMD20
Carbon dioxide transmitter for duct mounting………………………………………………
$360
GMD20D
Same as GMD20 plus local display and relay……………………………………………...
$410
GMW21
Carbon dioxide transmitter for wall mounting………………………………………………
$330
GMW21D
Same as GMW21 plus local display and relay……………………………………………..
$380
GMA20T
Analog temperature option for GMW21 with 0 to 10V output…………………………….
$60
GMI21
Local display and relay option for GM20 series transmitters……………………………..
$80
GMR20
Relay option for GM20 series transmitters………………………………………………….
$60
19040GM
Serial COM adapter for calibrating GM20 series transmitters……..……………………..
$100
GML20
Lonworks module for GM20 series transmitters……………………………………………
$170
GML20T
Lonworks module including temperature for GMW21……………………………………..
$240
GMW115
Carbon dioxide transmitter for wall mounting………………………………………………
$300
STATIC PRESSURE HEADS
SPH10
Static pressure head…………………………………………………………………………..
$270
SPH20
Static pressure head, heated…………………………………………………………………
$820
OEM Products, Call 1-888-VAISALA (824-7252) for pricing
HMM210
Humidity modules for environmental chambers.
HMM100
Humidity modules for environmental chambers.
HMT310
Humidity and temperature transmitters with small size and 6 probe choices.
DMT142
Miniature dewpoint transmitter.
MMT310
Moisture and temperature transmitters for oil.
MMT162
Compact moisture in oil and temperature transmitter.
GMM111
Carbon dioxide module with 0-5, 0-10 and 0-20% measuring ranges.
GMM112
Carbon dioxide module for HVAC applications.
GMM20W
Carbon dioxide module.
GMM220
Carbon dioxide module for demanding applications.
FINLAND
Vaisala Oyj
P.O.Box 26
FI-00421 Helsinki
FINLAND
Tel. +358 9 894 91
Fax +358 9 8949 2485
[email protected]
www.vaisala.com
BENELUX
Contact: Bonn Office
Adenauerallee 15
D-53111 Bonn
GERMANY
Tel. +49 228 24971 23
Fax +49 228 24971 11
Toll free Netherlands :
00800 -282 472 52
Toll free Belgium:
0800 17 200
[email protected]
www.vaisala.nl
www.vaisala.be
FRANCE
Vaisala SAS
Marseille Office
2, rue de Beausset
F-13001 Marseille
FRANCE
Tel. +33 4 88 66 17 51
+ 0800 67 67 26
[email protected]
www.vaisala.fr
Vaisala SAS
Paris Office
2, rue Stéphenson
F-78181
Saint-Quentin-en-Yvelines
Cedex
FRANCE
Tel. +33 1 3057 7342
Fax. +33 1 3096 0858
+ 0800 67 67 26
[email protected]
www.vaisala.fr
218
GERMANY
Vaisala GmbH
Bonn Office
Adenauerallee 15
D-53111 Bonn
GERMANY
Tel. +49 228 24971 0
Fax. +49 228 24971 11
National: 0800VAISALA
[email protected]
www.vaisala.de
Vaisala Oyj
Stockholm Office
Johanneslundsvägen 2
S-194 61 Upplands Väsby
SWEDEN
Tel. +46 8 750 94 20
Fax. +46 200 8490 849
National (tel.): 0200 848 848
National (fax.): 0200 849 849
[email protected]
www.vaisala.se
Vaisala GmbH
Hamburg Office
Schnackenburgallee 41D
D-22525 Hamburg
GERMANY
Tel. +49 40 8390 3160
Fax. +49 40 8390 3110
National: 0800VAISALA
[email protected]
www.vaisala.de
SWITZERLAND
Contact: Bonn Office
Adenauerallee 15
D-53111 Bonn
GERMANY
Tel. +49 228 24971 0
Fax. +49 228 24971 11
[email protected]
www.vaisala.de
Vaisala GmbH
Uhingen Office
Bahnhofstraße 3
D-73066 Uhingen
GERMANY
Tel. +49 7161 65494 40
Fax. +49 7161 65494 50
National: 0800VAISALA
[email protected]
www.vaisala.de
UNITED KINGDOM
Vaisala Ltd
Birmingham Office
Vaisala House
349 Bristol Road
Birmingham B5 7SW
UNITED KINGDOM
Tel. +44 121 683 1257
Fax +44 1638 576 240
[email protected]
www.vaisala.com
SWEDEN
Vaisala Oyj
Malmö Office
Drottninggatan 1 D
S-212 11 Malmö
SWEDEN
Tel. +46 40 298 991
Fax +46 40 298 992
National (tel.): 0200 848 848
National (fax.): 0200 849 849
[email protected]
www.vaisala.se
Vaisala Ltd
Newmarket Office
Unit 9,
Swan Lane
Exning
Newmarket
Suffolk CB8 7FN
UNITED KINGDOM
Tel. +44 1638 576 200
Fax +44 1638 576 240
[email protected]
www.vaisala.com
NORTH AMERICA
Vaisala Inc.
Boston Office
10-D Gill Street
Woburn, MA 01801
USA
Tel. +1 781 933 4500
Toll free 1-888-VAISALA
(824-7252)
Fax. +1 781 933 8029
[email protected]
www.vaisala.com
ASIA AND PACIFIC
AUSTRALIA
Vaisala Pty Ltd
Melbourne Office
3 Guest Street
Hawthorn, VIC 3122
AUSTRALIA
Tel: +61 3 9815 6700
Fax: +61 3 9815 6799
Freecall: 1800 335 840
[email protected]
vaisala.com
www.vaisala.com
CHINA
Vaisala China Ltd
Beijing Office
Floor 2, EAS Building
No.21, Xiao Yun Road,
Dongsanhuan Beilu
CHINA
Tel. +86 10 85261199
Fax. +86 10 85261155
[email protected]
cn.vaisala.com
JAPAN
Vaisala KK
Tokyo Office
42 Kagurazaka 6-Chome
Shinjuku-Ku
Tokyo 162-0825
JAPAN
Tel. + 81 3 3266 9611
Fax. + 81 3 3266 9610
[email protected]
www.vaisala.co.jp
219
HVAC
LUBRICATION
POWER
GENERATION
COMPRESSED
AIR
BUILDING
AUTOMATION
LIFE SCIENCE
ACCURATE
INSTRUMENTS
HIGH-TECH
CLEANROOMS
CHAMBERS
RELIABLE
MEASUREMENTS
SERVICES
www.vaisala.com
www.vaisala.com
For more information, visit
www.vaisala.com or contact
us at [email protected]
Ref. B211016EN-A ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement