Vaisala HUMICAP MMT310 Datasheet

HUMIDITY / DEW POINT / MOISTURE IN OIL / CARBON DIOXIDE / OXYGEN / BAROMETRIC PRESSURE / WIND Vaisala – at your service We at Vaisala have always valued the opportunity to push ourselves and our products to a higher level for the benefit of our customers. Our new strategy nurtures this opportunity, allowing us to focus on customers who operate in tightly controlled and demanding areas in the chosen industrial applications introduced in this catalog. We are confident that concentrating Vaisala's product and business development efforts on these areas will result in the overall success of our customers. The very core of Vaisala still is our unique devotion to products: the stability, reliability and performance that we have always been known and recognized for. With over 70 years of experience, close to 30 offices worldwide and thousands of customers in over 120 countries, Vaisala is an esteemed leader in innovating, manufacturing and servicing highquality instruments and systems. Our products have been designed to meet the customers' measurement needs in the most demanding industrial processes and controlled environments. This catalog introduces Vaisala's measurement instrument offering for industrial customers. Our professional sales force all over the world is at your service, ready to help you choose just the right solution for your specific measurement needs. I wish you every success with your business – we are at your service. Solutions to HVAC&R measurement needs Vaisala serves building automation customers in a variety of HVAC&R measurement needs, providing the best solutions for energy optimization, Indoor Air Quality (IAQ) and Demand Controlled Ventilation (DCV)in diverse and demanding environments. Whether you are an OEM, integrator, contractor, or responsible for facility HVAC management, we have an answer to your specific business needs. See Building Automation offering, page 6. Efficiency and productivity in controlled environments Our cleanrooms and chambers group can help you increase the efficiency and productivity of your operations in controlled environments. Whatever the industry – life science, food, microelectronics, automotive, you name it – cleanrooms & dryrooms, laboratories, incubators, environmental test chambers, warehouses and various other critical environments all benefit from Vaisala's solutions that minimize downtime and maximize yield. See Cleanrooms and Chambers offering, pages 7-8. Improved industrial processes Many industries, such as power, pharmaceutical, marine and plastics industries, benefit from the wide range of Vaisala's measurement instruments. Accurate, stable and reliable measurements can improve your industrial processes, energy efficiency and end-product quality. Applications in which Vaisala measurement instruments and our excellent services help our customers include e.g. monitoring the quality of compressed air, lubricating and transformer oils, as well as controlling various drying processes . See Targeted Industrial Applications offering, pages 8-9. A job well done In any industrial environment, installing the best quality solutions – on time and on budget – can pose a real challenge. By drawing on our application knowledge and product expertise you can always rely on getting just the right solution for your needs. Vaisala’s offering ranges from lightweight, hand-held instruments and OEM models to configurable fixed transmitters designed to meet the most stringent of demands. The standard delivery time for a configured product is three business days. For re-calibration, our regional Service Centers offer express services. See Service offering, pages 148-157. Kenneth Forss Executive Vice President Controlled Environment Vaisala Go to www.vaisala.com for the latest updates and other product news. 2 3 Table of Contents by Parameters Moisture in Oil MMT330 Moisture and Temperature Transmitter Series for Oil .................................................................... 86 MMT310 Series Moisture and Temperature Transmitter for Oil..................................................................... 92 MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM Applications ................................. 94 Humidity MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in Oil ................................................ 96 HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10 HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14 Carbon Dioxide HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15 GMP343 Carbon Dioxide Probe for Demanding Measurements..................................................................... 98 HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16 GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100 HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17 GMM220 Carbon Dioxide Modules forDemanding OEM Applications ...........................................................102 HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18 GMM111 Carbon Dioxide Module .............................................................................................................. 104 HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19 GM70 Hand-Held Carbon Dioxide Meterfor Spot-Checking Applications ..................................................... 106 HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20 GMW115 Carbon Dioxide Transmitter for Demand-controlled Ventilation ................................................... 108 HMT310 Humidity and Temperature Transmitter ........................................................................................ 26 GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications .................. 110 HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28 GMM112 Carbon Dioxide Module for HVAC Applications ..............................................................................112 DMW19 Wall Mount Dewpoint Transmitters for Indoor Applications............................................................. 30 GMM20W Carbon Dioxide Modulefor OEM Applications ............................................................................. 114 HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32 GML20 and GML20T LonWorks® Options for GMD/W20 Series ................................................................... 116 HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34 HMW40/50 and HMD40/50 Wall and Duct Mount Transmitters for HVAC Applications ................................... 36 Oxygen HMM210 Series Humidity Modules for Environmental Chambers ................................................................. 38 OMT355 Oxygen Transmitter for Industrial Process Measurements ............................................................ 118 HMM100 Humidity Module for Environmental Chambers ............................................................................40 OMT364 Oxygen Transmitter for Hazardous Areas .................................................................................... 122 HMP60 Humidity and Temperature Probe .................................................................................................. 42 HMP110 Humidity and Temperature Probe ................................................................................................. 44 Barometric Pressure HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46 PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications ..............124 HMI41 Indicator and HMP46 High Temperature Probe ................................................................................. 48 PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users ...............................130 HMP41, HMP42 and HMP45 Probes for HMI41 Indicator ................................................................................ 50 PTB330TS Barometric Pressure Transfer Standard - Take the Lab to the Field ............................................. 132 HM34 Pocket Size Relative Humidity Meter ................................................................................................. 52 PTB330TS Barometric Pressure Transfer Standard .....................................................................................134 HMK15 Humidity Calibrator ........................................................................................................................ 54 PTB210 Digital Barometer .......................................................................................................................... 136 HMP155 Humidity and Temperature Probe .................................................................................................. 56 PTB110 Barometer for Industrial Use .......................................................................................................... 138 DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58 SPH10/20 Static Pressure Heads for Minimizing Wind Induced Error ........................................................... 140 HMD60UO/YO Outdoor Humidity and Temperature Transmitter & Solar Radiation Shield ............................. 60 HMT330MIK Meteorological Installation Kit ................................................................................................ 62 Wind HMT300TMK Turbine Mounting Kit for Power Turbine Intake Air Measurement............................................ 64 WXT520 Weather Transmitter ....................................................................................................................142 WMT52 Ultrasonic Wind Sensor for Accurate and Stable Measurement ...................................................... 144 Dew Point WA15 Wind Set for High Performance Wind Measurement...........................................................................146 DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions ........................................ 66 DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications ........................................ 72 DMT242 Dewpoint Transmitter for OEM Applications .................................................................................. 76 DMT152 Dewpoint Transmitter for Low Dewpoint Measurement in OEM Applications .................................. 78 DMT142 Miniature Dewpoint Transmitter for OEM Applications ................................................................... 80 DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications................................................................ 82 DSS70A Portable Sampling System and Sampling Cells for DM70................................................................... 84 4 Vaisala Service Offering .................................................................................................................148 Calibration is Our Core Operation .............................................................................................. 151 Spare Filters ....................................................................................................................................... 158 Pricing for Configurable Products .............................................................................................. 161 Pricing for Standard, Non-Configurable Products ............................................................... 217 Vaisala Contact Information ......................................................................................................... 219 5 Table of Contents by Focus Area Building Automation Cleanrooms and Chambers HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10 HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10 HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14 HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14 HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15 HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15 HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16 HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16 HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17 HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17 HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18 HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18 HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19 HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19 HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20 HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20 HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28 HMT310 Humidity and Temperature Transmitter ........................................................................................ 26 DMW19 Wall Mount Dewpoint Transmitters for Indoor Applications............................................................. 30 HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28 HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32 HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32 HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34 HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34 HMW40/50 and HMD40/50 Wall and Duct Mount Transmitters for HVAC Applications ................................... 36 HMM210 Series Humidity Modules for Environmental Chambers ................................................................. 38 HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46 HMM100 Humidity Module for Environmental Chambers ............................................................................40 HMI41 Indicator and HMP46 High Temperature Probe ................................................................................. 48 HMP60 Humidity and Temperature Probe .................................................................................................. 42 HMP41, HMP42 and HMP45 Probes for HMI41 Indicator ................................................................................ 50 HMP110 Humidity and Temperature Probe ................................................................................................. 44 HM34 Pocket Size Relative Humidity Meter ................................................................................................. 52 HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46 HMK15 Humidity Calibrator ........................................................................................................................ 54 HMI41 Indicator and HMP46 High Temperature Probe ................................................................................. 48 HMP155 Humidity and Temperature Probe .................................................................................................. 56 HMP41, HMP42 and HMP45 Probes for HMI41 Indicator ................................................................................ 50 DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58 HM34 Pocket Size Relative Humidity Meter ................................................................................................. 52 HMD60UO/YO Outdoor Humidity and Temperature Transmitter & Solar Radiation Shield ............................. 60 HMK15 Humidity Calibrator ........................................................................................................................ 54 GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100 HMP155 Humidity and Temperature Probe .................................................................................................. 56 GM70 Hand-Held Carbon Dioxide Meterfor Spot-Checking Applications ..................................................... 106 DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58 GMW115 Carbon Dioxide Transmitter for Demand-controlled Ventilation ................................................... 108 DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions ........................................ 66 GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications .................. 110 DMT242 Dewpoint Transmitter for OEM Applications .................................................................................. 76 GMM112 Carbon Dioxide Module for HVAC Applications ..............................................................................112 DMT152 Dewpoint Transmitter for Low Dewpoint Measurement in OEM Applications .................................. 78 GMM20W Carbon Dioxide Module for OEM Applications ............................................................................ 114 DMT142 Miniature Dewpoint Transmitter for OEM Applications ................................................................... 80 GML20 and GML20T LonWorks Options for GMD/W20 Series ................................................................... 116 DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications................................................................ 82 SPH10/20 Static Pressure Heads for Minimizing Wind Induced Error ........................................................... 140 GMP343 Carbon Dioxide Probe for Demanding Measurements..................................................................... 98 WXT520 Weather Transmitter ...................................................................................................................142 GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100 WMT52 Ultrasonic Wind Sensor for Accurate and Stable Measurement ...................................................... 144 GMM220 Carbon Dioxide Modules for Demanding OEM Applications ..........................................................102 ® WA15 Wind Set for High Performance Wind Measurement...........................................................................146 Service offering, pages 148–157 6 7 Cleanrooms and Chambers continued Targeted Industrial Applications continued GMM111 Carbon Dioxide Module .............................................................................................................. 104 HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications ..................................... 46 GM70 Hand-Held Carbon Dioxide Meterfor Spot-Checking Applications ..................................................... 106 HMK15 Humidity Calibrator ........................................................................................................................ 54 GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications .................. 110 DTR500 Solar Radiation and Precipitation Shields ....................................................................................... 58 OMT355 Oxygen Transmitter for Industrial Process Measurements ............................................................ 118 HMT330MIK Meteorological Installation Kit ................................................................................................ 62 PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications ..............124 HMT300TMK Turbine Mounting Kit for PowerTurbine Intake Air Measurement ............................................. 64 PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users ...............................130 DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions ........................................ 66 PTB330TS Barometric Pressure Transfer Standard - Take the Lab to the Field ............................................. 132 DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications ........................................ 72 PTB330TS Barometric Pressure Transfer Standard .....................................................................................134 DMT242 Dewpoint Transmitter for OEM Applications .................................................................................. 76 PTB210 Digital Barometer .......................................................................................................................... 136 DMT152 Dewpoint Transmitter for Low Dewpoint Measurement in OEM Applications .................................. 78 PTB110 Barometer for Industrial Use .......................................................................................................... 138 DMT142 Miniature Dewpoint Transmitter for OEM Applications ................................................................... 80 WXT520 Weather Transmitter ...................................................................................................................142 DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications................................................................ 82 DSS70A Portable Sampling System and Sampling Cells for DM70................................................................... 84 Service offering, pages 148–157 MMT330 Moisture and Temperature Transmitter Series for Oil .................................................................... 86 MMT310 Series Moisture and Temperature Transmitter for Oil..................................................................... 92 MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM Applications ................................. 94 MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in Oil ................................................ 96 GMT220 Series Carbon Dioxide Transmitters for Industrial Applications ................................................... 100 Targeted Industrial Applications GMM220 Carbon Dioxide Modules for Demanding OEM Applications ..........................................................102 HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement ..................10 GMM111 Carbon Dioxide Module .............................................................................................................. 104 HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications ......................... 14 GMM112 Carbon Dioxide Module for HVAC Applications ..............................................................................112 HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces ................................................ 15 OMT355 Oxygen Transmitter for Industrial Process Measurements ............................................................ 118 HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications ....................... 16 OMT364 Oxygen Transmitter for Hazardous Areas .................................................................................... 122 HMT335 Humidity and Temperature Transmitter for High Temperatures....................................................... 17 PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications ..............124 HMT337 Humidity and Temperature Transmitter for High Humidity Applications .......................................... 18 PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users ...............................130 HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines ................................................... 19 PTB330TS Barometric Pressure Transfer Standard - Take the Lab to the Field ............................................. 132 HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters ................................................... 20 PTB330TS Barometric Pressure Transfer Standard .....................................................................................134 HMT310 Humidity and Temperature Transmitter ........................................................................................ 26 HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications .......................... 28 Service offering, pages 148–157 HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications .................................... 32 HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications ......................... 34 8 9 Humidity www.vaisala.com HMT330 Series Humidity and Temperature Transmitters for demanding humidity measurement Graphical display of history and measurement trends The HMT330 can be ordered with a large numerical and graphical display, which allows the user to clearly monitor operational data, measurement trends and 1-year measurement history. The optional data logger with real-time clock makes it possible to generate over four years of measured history, and zoom in on any desired time or time frame. The battery backup of the clock guarantees a reliable logging of measured data. The display alarm allows tracking of any measured parameter, with a freely configurable low and high limit. Data collection and (wireless) transfer to PC The recorded measurement data can be viewed on the display or transferred to a PC with Microsoft Windows® software. The transmitter can also be connected to a network with an optional (W)LAN interface, which enables a (wireless) Ethernet connection. A USB-RJ45 cable makes it easy to connect the service port of the HMT330 to a PC. Many ways to install and versatile outputs Mains and DC power options, and several mounting accessories make the instrument easy to install. analog outputs. Isolated galvanic power supply and analog outputs are also available. For serial interface the USB connection, RS232 and RS485 can be used. Flexible calibration The HMT330 instruments are calibrated at six humidity points at the factory. A quick, one-point field calibration can be performed with the hand-held HM70 meter. A twopoint calibration can be performed with the HMK15 salt bath calibrator in a controlled environment. The transmitter can be sent to Vaisala for recalibration. Accredited calibrations and maintenance contracts are also available. The HMT330 can have up to three The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Features/Benefits ▪ Six models for demanding industrial applications ▪ Full 0 ... 100 %RH measurement, temperature range up to +180 °C (+356 °F) (depending on model) ▪ Pressure tolerance up to 100 bar (depending on model) ▪ Next generation Vaisala HUMICAP® Sensor for excellent accuracy and stability ▪ Graphical display of measurement trends and over four-year history ▪ ▪ Multilingual user interface ▪ Corrosion resistant IP65 housing ▪ NIST traceable (certificate included) ▪ Analog outputs, WLAN/LAN 10 The Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT330 is designed for demanding industrial applications where stable measurement and wide customization is important. Vaisala HUMICAP ® performance The HMT330 series incorporates Vaisala’s 30 years of experience in industrial humidity measurement. An updated, even more stable and chemical resistant HUMICAP® sensor is available, next to the proven reliable and accurate sensor. Chemical purge minimizes effects of contaminants In environments with high concentrations of chemicals and cleaning agents, chemical purge helps to maintain measurement accuracy between calibration intervals. Chemical purge involves heating the sensor to remove harmful chemicals. The function can be initiated manually or programmed to occur at set intervals. Excellent performance in harsh chemical concentrations 11 Technical data Performance Inputs and outputs Mechanics Dimensions RELATIVE HUMIDITY Operating voltage 10 ... 35 VDC, 24 VAC with optional power supply module 100 ... 240 VAC, 50/60 HZ Power consumption at +20 °C (Uin 24 VDC) RS-232 max. 25 mA Uout 2 x 0 ... 1 V/0 ... 5 V/0 ... 10 V max. 25 mA max. 60 mA Iout 2 x 0 ... 20 mA display and backlight + 20 mA during chemical purge max. 110 mA during probe heating (HMT337) + 120 mA Analog outputs (2 standard, 3rd optional) current output 0 ... 20 mA, 4 ... 20 mA voltage output 0... 1 V, 0... 5 V, 0... 10 V Accuracy of analog outputs at +20 °C ±0.05% full scale Temperature dependence of the analog outputs ±0.005%/°C full scale External loads current outputs RL < 500 ohm 0 ... 1 V output RL > 2 kohm 0 ... 5 V and 0 ... 10 V outputs RL > 10 kohm Max. wire size 0.5 mm2 (AWG 20) stranded wires recommended Digital outputs RS-232, RS-485 (optional) Service connection RS-232, USB Relay outputs (optional) 0.5 A, 250 VAC Ethernet interface (optional) Supported standards 10/100Base-T Connector RJ45 Protocols Telnet Software support Vaisala MI70 link WLAN interface (optional) Supported standards 802.11b Antenna connector type RP-SMA Protocols Telnet Security WEP 64/128,WPA Software support Vaisala MI70 link Authentication / Encryption (WLAN) Open / no encryption Open / WEP WPA Pre shared key / TKIP WPA Pre shared key / CCMP (a.k.a. WPA2) Optional data logger with real-time clock Logged parameters max. three with trend/min/max values Logging interval 10 sec (fixed) Max. logging period 4 years 5 months Logged points 13.7 million points per parameter Battery lifetime min. 5 years Display LCD with backlight, graphic trend display of any parameter Menu languages English, Chinese, Japanese, Spanish, German, French, Swedish, Russian, Finnish Cable bushing M20 x 1.5 for cable diameter Measurement range 8 ... 11 mm/0.31 ... 0.43" Conduit fitting 1/2" NPT User cable connector (optional) M12 series 8-pin (male) option 1 female plug with 5 m (16.4 ft) black cable option 2 female plug with screw terminals Probe cable diameter HMT333 (+80 °C) 6.0 mm other probes 5.5 mm Housing material G-AlSi 10 Mg (DIN1725) Housing classification IP 65 (NEMA4) Dimensions in mm (inches) TEMPERATURE Accuracy at +20 °C (+68 °F) ± 0.2 °C (± 0.36 °F) Accuracy over temperature range (measurement range depends on model) °C 0.7 0.6 0.5 0.4 0.3 0.2 0.1 °C 0 -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -80 -60 -40 -20 0 20 40 60 80 100 120 140 160 180 Temperature sensor PT 100 RTD 1/3 Class B IEC 751 Other variables available (depends on model) dewpoint temperature, mixing ratio, absolute humidity, wet bulb temperature, enthalpy, water vapor pressure 12 Transmitter with WLAN antenna 183 (7.20) Operating temperature for probe for transmitter body with display Electromagnetic compatibility same as measurement range -40 ... +60 °C (-40 ... 140 °F) 0 ... +60 °C (32 ... 140 °F) Complies with EMC standard EN61326-1, Industrial Environment 116 (4.57) Operating environment 106 (4.17) Measurement range 0 ... 100 %RH Accuracy (including non-linearity, hysteresis, and repeatability) for typical applications with Vaisala HUMICAP® 180 or 180R with Vaisala HUMICAP® 180C or 180RC for applications with chemical purge/warmed probe at +15 ... +25 °C (59 ... +77 °F) ±1 %RH (0 ... 90 %) ±1.7 %RH (90 ... 100 %RH) at -20 ... +40 °C (-4 ... +104 °F) ±(1.0 + 0.008 x reading) %RH at -40 ... +180 °C (-40 ... +356 °F) ±(1.5 + 0.015 x reading) %RH Factory calibration uncertainty (+20 °C) ± 0.6 %RH (0 ... 40 %RH) ± 1.0 %RH (40 ... 97 %RH) (Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate.) Response time (90 %) at +20 °C (+68 °F) 8 s / 17 s* with grid filter in still air 20 s / 50 s* with grid + steel netting filter 40 s / 60 s* with sintered filter * with HUMICAP® 180R or 180RC sensor Mounting options Mounting with Wall Mounting Kit Mounting with DIN Rail Installation Kit Pole Installation with Installation Kit for Pole or Pipeline Mounting Rain Shield with Installation Kit TYPE APPROVED PRODUCT CERTIFICATE NO.: A-11440 For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210951EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 13 HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces 210697 duct installation kit for HMT333 and HMT337. HMT331 Humidity and Temperature Transmitter for demanding wallmounted applications ▪ For temperatures -40 ... +60 °C (-40 ... +140 °F) ▪ Application examples: cleanrooms, pharmaceutical processes, greenhouses, swimming halls, museums and archives Technical Data Temperature measurement range -40 ... +60 °C (-40 ... +140 °F) Accessories PC software + cable USB-RJ45 Serial Connection Cable Connection cable for HM70 Wall mounting plate (plastic) Pole installation kit Rain shield DIN rail installation set Dimensions Dimensions in mm (inches) 14 215005 219685 211339 214829 215108 215109 215094 The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT331 is the top-of-the-line wall-mounted transmitter for demanding HVAC and condition monitoring applications. Compared to regular wall-mounted transmitters, the HMT331 offers, higher measurement performance, better chemical tolerance, advanced graphical display features, more powering options, more output options and a wider variety of output humidity parameters. Graphical display of history and measurement trends The HMT330 series features a large numerical and graphical display, allowing users to easily monitor operational data, measurement trends and one-year measurement history. The optional data logger with realtime clock makes it possible to generate over four years of measured history, and zoom in on any desired time or time frame. Outputs and power supply options for every need Features/Benefits ▪ For remote probe installations in demanding HVAC applications ▪ For temperatures -40 ... +80 °C (-40 ... +176 °F) or -40 ... +120 °C (-40 ... +248 °F) ▪ Small thermal mass - fast response to temperature changes ▪ Application examples: cleanrooms, pharmaceutical processes, greenhouses, environmental chambers The output options include three analog outputs, RS-232, RS-485, and alarm relays. The voltage supply range is from 10 to 35 VDC. With an additional module, the transmitter can be connected to all universal mains AC supplies. The input/output cable can be fed through the back of the transmitter, which is a useful feature, especially for installations in cleanrooms. For moderate humidities and temperatures The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT333 is a versatile instrument for applicatons where a small remote probe is needed. Flexible installation To install the probe in ducts, channels and through walls, an installation kit is available with an aluminum flange, lead-through piece, and steel support bar. HMT333 has two probe cable options available, a flexible one that withstands heat up to +80° C, and a durable cable that withstands heat up to +120° C. Both cable options are available in lengths of 2, 5, and 10 meters. Ø 12 (0.47) Features/Benefits The HMT333 transmitter has a small probe for remote applications. M9x1 The HMT331 is the state-of-the-art wall-mount humidity instrument. For outdoor environments, the DTR502B solar radiation shield provides protection for the probe. The shield can be installed on a pole, a beam or a flat surface. 37.5 (1.48) 78.5 (3.09) 98.5 (3.88) The HMT333 is typically used in demanding HVAC applications such as cleanrooms, pharmaceutical processes, and greenhouses, or in processes of moderate temperature. For environments with continuously high humidity, the HMT337 with a warmed, vapor-tight and stainless steel probe is recommended. Technical Data Temperature measurement range -40 ... +80 °C (-40 ... +176 °F) or -40 ... +120 °C (-40 ... +248 °F) Accessories Duct installation kit 210697 Cable gland HMP247CG PC software + cable 215005 USB-RJ45 Serial Connection Cable 219685 Connection cable for HM70 211339 Wall mounting plate (plastic) 214829 Pole installation kit 215108 Rain shield 215109 Solar radiation shield DTR502B DIN rail installation set 215094 Dimensions Dimensions in mm (inches) 15 HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications HMT335 Humidity and Temperature Transmitter for High Temperatures The installation flange allows an adjustable installation depth for the probe. The display shows measurement trends and over four-year real time measurement history. The HMT335 has a robust stainless steel probe ideal for high flow rates in hot processes. Features/Benefits ▪ For pressures up to 100 bar and vacuum applications ▪ For temperatures -70 ... +180 °C (-94 ... +356 °F) ▪ ▪ ISO and NPT threads available Application example: test chambers Vaisala HUMICAP® performance Accessories Dimensions Dimensions in mm (inches) 16 210697 17225 215005 219685 211339 214829 215108 215109 215094 M22×1.5 or NPT 1/2" Temperature measurement range -70 ... +180 °C (-94 ... +356 °F) Operating pressure 0 ... 10 MPa (0 ... 100 bar) The HMT334 incorporates Vaisala’s more than 30 years of experience in industrial humidity measurement. The sensor provides accurate and reliable measurement and is immune to particulate contamination and most chemicals. ø12 (0.47) Technical Data Fitting body ISO M22 x 1.5 Fitting body NPT 1/2" PC software + cable USB-RJ45 Serial Connection Cable Connection cable for HM70 Wall mounting plate (plastic) Pole installation kit Rain shield DIN rail installation set The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT334 is designed to measure humidity in pressurized spaces or vacuum chambers. Each probe is tested to ensure a gas and vacuum tight installation. 41 (1.61) 120 (4.72) 170 (6.69) Graphical display of measurement trends and real time history Features/Benefits ▪ For temperatures -70 ... +180 °C (-94 ... +356 °F) The HMT330 series features a numerical and graphical display. The user can easily monitor operational data, measurement trends and up to one-year history. ▪ ▪ Long metal probe head ▪ ▪ Adjustable installation depth The optional data logger with realtime clock makes it possible to generate more than four years of measured history, and zoom in on any desired time or time frame. Using a serial line, the measurement data can be transferred to a PC where it can be further processed and copied to other programs. The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT335 has a long stainless steel probe designed for high temperatures. Robust probe ideal for high flow rates Stainless steel installation flange available Application example: hot drying processes The HMT335 is ideal for duct measurements as the probe tolerates mechanical stress and withstands high flow rates. The HMT335 can be used, for example, in a hot drying process. Technical Data Graphical display of history and measurement trends Temperature measurement range -70 ... +180 °C (-94 ... +356 °F) The HMT335 features a numerical and graphical display. The user can easily monitor measurement operational data, measurement trends and oneyear measurement history. The optional data logger with realtime clock makes it possible to generate more than four years of measured history, and zoom in on any desired time or time frame. Vaisala HUMICAP® performance The sensor provides accurate and reliable measurement and is immune to particulate contamination and most chemicals. Accessories Mounting flange PC software + cable USB-RJ45 Serial Connection Cable Connection cable for HM70 Wall mounting plate (plastic) Pole installation kit Rain shield DIN rail installation set Dimensions Dimensions in mm (inches) 210696 215005 219685 211339 214829 215108 215109 215094 41 (1.6) 51 (2.0) ø13.5 (0.53) The HMT334 is ideal for permanent installations into pressurized or vacuum processes. 192 (7.56) 253 (9.96) 17 HMT337 Humidity and Temperature Transmitter for High Humidity Applications HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines down to the appropriate depth. The hex nut is tightened with a wrench to lock the probe in its place. Hot tapping is possible in pressures up to 10 bar. Graphical display of history and measurement trends Duct installation kit From the display, the user can easily monitor operational data, measurement trends and one-year measurement history. Features/Benefits The HMT337 is the ideal transmitter for the most demanding process and meteorological measurements. Technical Data Temperature measurement range -70 ... +180 °C (-94 ... +356 °F) Accessories Cable gland and AGRO HMP247CG Duct installation kit (RH probe) 210697 Duct installation kit (T probe) 215003 Swagelok fittings (NPT and ISO) for both RH and T probes Solar radiation shield DTR502B Meteorological inst. kit HMT330MIK PC software + cable 215005 USB-RJ45 Serial Connection Cable 219685 Connection cable for HM70 211339 Wall mounting plate (plastic) 214829 Pole installation kit 215108 Rain shield 215109 DIN rail installation set 215094 Dimensions ▪ Warmed probe for superior performance in condensing environments ▪ Small, stainless steel, vaportight remote probe ▪ For temperatures -70 ... +180 °C (-94 ... +356 °F) The HMT338 is ideal for installations in pressurized processes where the probe needs to be removed while the is running. measurement in environments where humidity is near saturation. The warming prevents condensation from forming on the sensor. Features/Benefits ▪ r #BTJDOPOXBSNFEQSPCFGPS moderate humidities As the probe is warmed, the humidity level inside it stays below the ambient level. With accurate temperature measurement, the ambient dewpoint can be calculated precisely. Installed through ball valve – can be inserted and removed while the process is running ▪ ▪ ▪ Adjustable probe depth If the relative humidity value is needed, an additional temperature sensor is used. The measured ambient temperature provides the compensation for calculating relative humidity and other humidity parameters. ▪ Two probe lengths available r 8JUIBXBSNFEQSPCFGPSOFBS condensing conditions and dew point measurement r 8JUIBXBSNFEQSPCFBOEBO additional temperature sensor: for near-condensing conditions and relative humidity measurement True humidity readings in conditions of condensation Many ways to install The Vaisala unique warmed probe provides fast and reliable M9×1 37.5 (1.48) 79.5 (3.13) 99.5 (3.92) 18 For high-humidity applications in industry and meteorology The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT337 is delivered in one of three configurations: ø 12 (0.47) Dimensions in mm (inches) ▪ A tight installation through a process wall can be achieved with Swagelok ® fittings. Meteorological installation kits for outdoor installations and duct installation kits are also available. Pressure tolerance 40 bar For temperatures -70 ... +180 °C (-94 ... +356 °F) The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT338 is designed for pressurized processes. Insert or remove probe while the process is running With “hot tapping”, the probe is inserted directly into the process while it is running, without the need for venting or lowering the process pressure. The probe is screwed into a ball valve assembly that has been fixed to the process pipe or wall. The adjustable hex nut is hand-tightened to temporarily hold the probe to the process. Then the probe is pushed The optional data logger with real-time clock makes it possible to generate more than four years of measured history, and zoom in on any desired time or time frame. The battery backup of the real-time clock guarantees a reliable logging of measured data. Vaisala HUMICAP® The HMT338 incorporates Vaisala’s more than 30 years of experience in industrial humidity measurement. The sensor provides accurate and reliable measurement and is immune to particulate contamination and most chemicals. Technical Data Temperature measurement range -70 ... +180 °C (-94 ... +356 °F) Operating pressure 0 ... 4MPa (0 ... 40 bar) Accessories Ball valve set BALLVALVE-1 Pressure fitting ISO 1/2 to NPT 1/2 210662 PC software + cable 215005 USB-RJ45 Serial Connection Cable 219685 Connection cable for HM70 211339 Wall mounting plate (plastic) 214829 Pole installation kit 215108 Rain shield 215109 DIN rail installation set 215094 Dimensions Dimensions in mm (inches) 19 HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Interchangeable Probes for HMT360 Intrinsically Safe Humidity and Temperature Transmitter The HMT360 offers six probe options for various applications: HMP361 HMP363 HMP364 HMP365 HMP367 HMP368 Features/Benefits ▪ ▪ ▪ ▪ ▪ Measures humidity and temperature, outputs also dewpoint, mixing ratio, absolute humidity and wet bulb temperature Safe operation with the entire transmitter in hazardous areas: Division 1 and 2 (USA, Canada), Categories 1G / Zone 0 and 1D / Zone 20 with protection cover (EU) Intrinsically safe Designed for harsh conditions Vaisala HUMICAP® Sensor features high accuracy, excellent long-term stability, and negligible hysteresis The Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT360 are the ideal solution for measuring humidity in hazardous areas. They operate safely and reliably even in the most hazardous classifications. The HMT360 transmitters' proven performance and technology conform with rigorous international standards. Intrinsically safe The entire HMT360 transmitter can be installed directly in explosive areas. It can withstand continuous exposure to potentially explosive environments that contain flammable gases or dust. ▪ ▪ Six probe options Customized configuration Temperature range between -40 … +180°C (-40 … +356°F) depending on the probe option Due to the microprocessor based electronics, options and accessories, the HMT360 series is truly flexible. ▪ NIST traceable (certificate included) 20 Temperature range -40 ... +60 °C (-40 ... +140 °F) Probe diameter 12 mm 41 (1.61) 86 (3.39) 127 (5) The HMP361 probe in this picture has a stainless steel netting filter. - wall mount - confined spaces - pressurized spaces - high temperature - high humidity - pressurized pipelines The interchangeable probes enable fast and easy removal or re-installation when required. Calibration, for example, is easy to perform due to the modular structure. All calibration coefficients are included in the probe unit itself, which means that probes can be switched between transmitter bodies without losing the accuracy. Dimensions in mm (inches) Technical Data Dimensions HMP363 for confined spaces Dimensions in mm (inches) Temperature range with The HMP363 probe is small and fits into tight spaces.This one is connected with a teflon cable. teflon cable -40 ... +120 °C (-40 ... +248 °F) rubber cable -40 ... +80 °C (-40 ... +176 °F) Probe cable length In addition to the standard Vaisala HUMICAP® Sensor, an application specific, very chemically durable sensor is also available. 75 (2.96) 50 (1.97) adjustable Installation Swagelok for 12mm probe, 1/2" NPT thread Installation flange: aluminum or stainless steel 12 mm flange Ø12 (0.47) Duct installation kit Optimized sensors Installation kit for duct mounting 2, 5 or 10 meters Probe diameter Cable Gland M20x1.5 with splitting seal 37.5 (1.48) 98.5 (3.88) 210697 duct wall HMP247CG drilling 16...22 (0.63...0.87) SWG12NPT12 Long-term solution Technical Data Dimensions The HMT360 transmitters are an investment; their rugged design, combined with trouble-free operation, ensure a long-term solution for monitoring humidity and dewpoint in explosive environments. HMP364 for high pressure Dimensions in mm (inches) Customized calibration and maintenance contracts for the HMT360 series are available on request. Temperature range Pressure range Probe cable length Probe diameter The HMP364 probe is designed for measurement in pressurized spaces or vacuum chambers. -40 ... +180 °C (-40 ... +356 °F) 0 ... 10 MPa (6.69) 2 (0.47) The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT361 wall mount transmitter, shown with six probe options, is designed specifically for hazardous and explosive environments. HMP361 for wall mounting 62 (2.44) Interchangeable probes Dimensions ø12 (o.47) Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration can also easily be made in the field. Technical Data ø 12 (0.47) www.vaisala.com 120 (4.72) (0.55) (1.14) 2, 5 or 10 meters 12 mm Fitting body M22x1.5 17223 Fitting body NPT1/2 17225 21 Technical data Temperature range operating temp. range for electronics with display storage Pressure range Dimensions HMP365 for high temperature Dimensions in mm (inches) Measurement range 0 ... 100 %RH Accuracy (including non-linearity, hysteresis, and repeatability) with Vaisala HUMICAP® 180 or 180R for typical applications at +15 ... +25 °C (59 ... +77 °F) ± 1.0 %RH (0 ... 90 %RH) -40 ... +180 °C (-40 ... +356 °F) 41 (1.6) 2, 5 or 10 meters Probe diameter ø13.5 (0.53) Technical Data Probe cable length 51 (2.0) 192 (7.56) 13.5 mm at -20 ... +40 °C (-4 ... +104 °F) 253 (9.96) 75 (2.96) Installation at -40 ... +180 °C (-40 ... +356 °F) 50 (1.97) Mounting flange 210696 Cable Gland M20x1.5 with splitting seal Installation flange: stainless steel HMP247CG Dimensions HMP367 for high humidities Dimensions in mm (inches) -40 ... +180 °C (-40 ... +356 °F) Probe cable length 2, 5 or 10 meters Probe diameter M9×1 Temperature range ø 12 (0.47) Technical Data 12 mm 37.5 (1.48) Installation 79.5 (3.13) Duct installation kit 210697 Cable Gland M20x1.5 with splitting seal HMP247CG Swagelok for 12mm probe, 3/8" ISO thread SWG12ISO38 Swagelok for 12mm probe, 1/2" NPT thread SWG12NPT12 ±1.7 %RH (90 ... 100 %RH) ±(1.0 + 0.008 x reading) %RH ± (1.5 +0.015 x reading) %RH with Vaisala HUMICAP® 180L2 drilling 16...22 (0.63...0.87) The HMP367 probe is constructed to be installed in environments with high humidities. Operating environment RELATIVE HUMIDITY Temperature range The HMP365 probe is designed for high temperature environments. Performance for application with demanding chemical environment at -10... +40 °C (14 ... +104 °F) ± (1.0 + 0.01 x reading) %RH at -40 ... +180 °C (-40 ... +356 °F) ± (1.5 + 0.02 x reading) %RH Factory calibration uncertainty (+20 °C) ± 0.6 %RH (0 ... 40 %RH) ± 1.0 %RH (40 ... 97 %RH) (Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate.) Response time (90 %) at +20 °C (+68 °F) in still air with grid filter 8 s / 17 s* with grid + steel netting filter 20 s / 50 s* with sintered filter 40 s / 60 s* * with HUMICAP® 180R sensor HMP368 for pressurized pipelines Dimensions in mm (inches) Probe cable length 2, 5 or 10 meters 41 (1.61) Ø13.5 (0.53) Dimensions 0 ... 4 MPa Mechanics Connections 0.5 0.1 The HMP368 probe enables flexible installation in pressurized pipelines. 13.5 mm/12 mm Two probe lenghts available. °C 0 -0.1 R ½ ISO 7/1 or NPT½" -0.2 41 - 149/371 (1.61 - 5.87/14.6)* 14 (0.55) 194/416 (7.64/16.4) Length for standard / optional probes *freely user adjustable length -0.3 -0.4 -0.5 -0.6 -0.7 -80 -60 -40 -20 0 20 40 60 80 100 120 140 160 180 Installation Fitting body ISO1/2 solid structure DRW212076SP Fitting body NPT1/2 solid structure Cable bushings Conduit fitting Housing material Housing classification Housing weight screw terminals, 0.33...2.0 mm 2 wires (AWG 14-22) For 7.5...12mm or 10...15mm cable diameters (M20) NPT 1/2" (M20) G-AlSi10Mg (DIN 1725) IP66 (NEMA 4X) 950 g Options and accessories 0.4 0.3 0.2 232/454 (9.13/17.9) Probe diameter Operating voltage 12 ... 28 V with serial port (service mode) 15 ... 28 V Analog outputs two-wire 4 ... 20 mA, one standard, one optional Typical accuracy of analog outputs at +20 °C ±0.05% full scale Typical temperature dependence of analog outputs 0.005% / °C (0.005% / °F) full scale Analog outputs connection via safety barriers RS232C serial output for service use connector type RJ45 Display two-line LCD Measurement range -40 ... +180 °C (-40 ... +356 °F) (depends on selected probe) Typical accuracy of electronics at +20 °C (+68 °F) ±0.2 °C (0.36 °F) Typical temparature dependence of electronics 0.005 °C/°C (0.005 °F/°F) Sensor Pt 1000 RTD 1/3 Class B IEC 751 Accuracy over temperature range Technical Data Pressure range Inputs and outputs TEMPERATURE °C 0.7 -40 ... +180 °C (-40 ... +356 °F) Complies with EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements; Industrial Environment. NOTE! IEC 1000-4-5 complies only when using external EXi approved surge arrester in the safe area. 99.5 (3.92) 0.6 Temperature range -40 ... +60 °C (-40 ... +140 °F) -20 ... +60 °C (-4 ... +140 °F) -40 ... +70 °C (-40 ... +158 °F) see probe specifications OTHER VARIABLES Optionally available dewpoint temperature, mixing ratio, absolute humidity, wet bulb temperature. Duct installation kit (for HMP363/367) 210697 Mounting flange (for HMP365) 210696 Ball valve ISO 1/2 with welding joint BALLVALVE-1 (for HMP368) pressure range at +20 °C (+68 °F): 0 ... 20 bar (0 ... 290 psia) (during installation max. 10 bar (145 psia) Calibration adapter for HMK15 211302 Serial interface cable for PC connectors RJ45 - D9 female 25905ZZ Galvanic isolator 212483 Zener barrier (USA & Canada) 210664 Protection cover (for use in the 214101 presence of combustible dust, ATEX) II 1 D IP65 T = 70 °C NPTFITBODASP Ball valve ISO 1/2 with welding joint BALLVALVE-1 22 23 Classification with current outputs Dimensions EUROPE / VTT Dimensions in mm (inches) Safety factors II 1 G Ex ia IIC T4 Ga VTT 09 ATEX 028 X issue No: 1 Ui = 28 V, Ii = 100 mA, Pi = 700 mW Ci = 1 nF, Li negligibly low Environmental specifications Tamb -40 ... +60 °C (-40 ... +140 °F) 0.8 ... 1.1 bar Pamb Dust classification (with protection cover) II 1 D (IP65 T=70 °C) VTT 04 ATEX 023X USA (FM) Classes I, II, III, Division 1, Groups A-G and Division 2, Groups A-D, F and G FM Project ID: 3010615 Safety factors: Vmax = 28 VDC, Imax = 100 mA, Ci = 1 nF, Li = 0, Pi = 0.7 W, Tamb= 60 °C(140 °F), T5 JAPAN (TIIS) Ex ia IIC T4 Code number: TC17897 Safety factors: Ui = 28 VDC, Ii = 100 mA, Ci = 1 nF, Pi = 0.7 W, Li = 0, Tamb= 60 °C (140 °F) 39 (1.5) 115 (4.53) EU (94/9/EC, ATEX100a) Accessories 164 (6.46) 125 (4.92) HMT361 73 (2.9) 11 (0.43) 62 (2.4) Accessory Ball valve ISO 1/2 with welding joint Cable Gland M20 x 1.5 with splitting seal Duct installation kit Fitting body ISO1/2 solid structure Fitting body M22 x 1.5 Fitting body NPT1/2 Fitting body NPT1/2 solid structure Mounting flange Swagelok for 12mm probe, 1/2" NPT thread Swagelok for 12mm probe, 3/8" ISO thread part number BALLVALVE-1 HMP247CG 210697 DRW212076SP 17223 17225 NPTFITBODASP 210696 SWG12NPT12 SWG12ISO38 HMT363 HMT364 HMT365 HMT367 √ √ √ HMT368 √ √ √ √ √ √ √ √ √ √ √ √ CANADA (CSA) Class I Class II Division 1 and Division 2, Groups A, B, C, D; Division 1 and Division 2, Groups G and Coal Dust; Class III CSA File No: 213862 0 000, CSA Report: 1300863 Safety factors: Tamb= 60 °C, T4, Intrinsically safe when connected as per Installation Drawing DRW213478. CHINA (PCEC) Ex ia II CT4 Certificate No. CE092145 Standard GB3836.1-2000 and GB3836.4-2000 IECEx (VTT) Ex ia IIC T4 Ga IECEx VTT 09.0002x issue No: 1 Safety factors Ui = 28 V, Ii = 100 mA, Pi = 700 mW Ci = 1 nF, Li negligibly low Environmental specification -40 ... +60 °C (-40 ... +140 °F) Tamb Pamb 0.8 ... 1.1 bar For more information, visit www.vaisala.com or contact us at [email protected] 24 Ref. B210956EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 25 www.vaisala.com HMT310 Humidity and Temperature Transmitter Technical data Measured values Electrical connections RELATIVE HUMIDITY typical applications applications with chemical purge and/or warmed probe Accuracy (incl. non-linearity, hysteresis and repeatability) at a temperature range of +15 ... +25 °C ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) -20 ... +40 °C ±(1.0 + 0.008 x reading) %RH -40 ... +180 °C ±(1.5 + 0.015 x reading) %RH Factory calibration uncertainty ±0.6 %RH (0 ... 40 %RH)* (+20 °C) ±1.0 %RH (40 ... 97 %RH)* Two analog outputs, 0 ... 20 mA or 4 ... 20 mA selectable and scalable Typical accuracy of analog output at +20 °C +0.05 % full scale Typical temperature dependence 0.005 %/°C (0.003 %/°F) of analog output of full scale Serial output RS--232C Connections M12 8-pole connector with RS-232C, current outputs (two channels) and Uin Operating voltage 12 ... 35 VDC, the maximum operating voltage for a device with sensor heating is 24 VDC Power consumption 30 mA with RS-232 External load Rl < 500 Ohm Startup time after powerup 3s * Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate. General Measurement range Sensor Vaisala HUMICAP®180R Vaisala HUMICAP®180RC 0 ... 100 %RH Response time (90 %) at +20 °C 17 s with grid filter in 0.1 m/s air flow 50 s with grid and steel, netting filter 60 s with sintered filter TEMPERATURE HMT311 HMT313 -40 ... +60 °C (-40 ... +140 °F) -40 ... +80 °C (-40 ... +176 °F) or -40 ... +120 °C (-40 ... +248 °F) HMT314, HMT315, HMT317, HMT318 -70 ... +180 °C (-94 ... +356 °F) The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT310 models (from left to right): HMT313, HMT317, HMT314, HMT318, HMT315 and HMT311. Accuracy over temperature range (see graph below) Features/Benefits ▪ ▪ Next-generation Vaisala HUMICAP® Sensor for excellent accuracy and stability Full 0 ... 100 %RH measurement, temperature range up to +180 °C (depending on model) ▪ ▪ Small size, easy to integrate ▪ NIST traceable Insensitive to dust and most chemicals Reliable Vaisala HUMICAP® technology The HMT310 incorporates the latestgeneration Vaisala HUMICAP® Sensor. The Vaisala HUMICAP® Sensor is a capacitive thin-film polymer sensor. It features high accuracy, excellent long-term stability and negligible hysteresis. It is insensitive to dust, particulate dirt and most chemicals. Several outputs, one connector The HMT310 is powered up with 12 ... 35 VDC. It has two analog outputs and an RS-232 serial output. The output signal and the supply power travel in the same cable, the only cable connected to the unit. 26 Chemical purge Chemical purge helps to maintain measurement accuracy between calibraton intervals and it involves heating the sensor to remove harmful chemicals. The function can be initiated manually or programmed to occur at set intervals. Δ °C 0.7 0.6 0.5 0.4 0.3 0.2 0.1 °C 0 -0.1 -0.2 -0.3 -0.4 -0.5 Optional functions The following optional functions are available: several probes for various applications, calculated humidity quantities, different mounting kits, sensor protection options and probe cable lengths, warmed probe and sensor heating for high humidity conditions (HMT317), and chemical purge for applications risking an interference with chemicals in the measuring environment. Operating temperature range for electronics -40 ... +60 °C (-40 ... +140 °F) Storage temperature range -55 .... +80 °C (-67 ... +176 °C) Operating pressure HMT314 0 ... 100 bar HMT318 0 ... 40 bar HMT315, HMT317 vapor tight Transmitter housing material G-AlSi10Mg Transmitter base material ABS/PC Housing classification IP65 Cable feed through 8-pole connector with 5 m cable, alternatives Female 8-pin connector screw joint for cable diameter 4 ... 8 mm Sensor protection PPS grid with stainless steel net, PPS grid, Sintered filter Membrane stainless steel filter Complies with EMC standard EN61326-1, Industrial environment -0.6 -0.7 -80 -60 -40 -20 0 Typical temperature dependence of electronics Temperature sensor 20 40 60 80 100 120 140 160 180 Note: When using the current output, the RF field susceptibility level according to standard EN61000-4-3 with a frequency band of 110 ... 165 MHz, is only 3V/m (generic environment) with the specified accuracy. +0.05 °C/°C (+0.005 °F/°F) Pt100 IEC751/3 class B For more information, visit www.vaisala.com or contact us at [email protected] HUMICAP® is a registered trademark of Vaisala. Ref. B210769EN-C ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 27 www.vaisala.com HMT100 Series Humidity and Temperature Transmitter for Demanding HVAC Applications Technical data Performance Inputs and outputs RELATIVE HUMIDITY Two-wire output signal External loop load Measurement range 0 ... 100 %RH Accuracy against factory standards including non-linearity, hysteresis, and repeatability at +15 ... +25 °C (+59 ... +77 °F) ±1.7 %RH (0 ... 90 %RH) ±2.5 %RH (90 ... 100 %RH) at ±0 °C ... +40 °C (+32 ... +104 °F) ±(1.7 +0.015 x reading) %RH at -40 ... ±0 °C, +40 ... +80 °C ±(2.0+0.025 x reading) %RH (-40 ... +32 °F, +104 ... +176 °F) Factory calibration uncertainty ±1.0 %RH (0 ... 15 %RH) at +20 °C (+68 °F) ±1.5 %RH (>15 ... 78 %RH) Response time (90 %) at 20 °C in 8 s with plastic grid still air 20 s with membrane filter 40 s with sintered filter Humidity sensor Vaisala HUMICAP® 180 TEMPERATURE Measurement range Accuracy at +20 °C (+68 °F) -40 ... +80 °C (-40 ... 176 °F) ±0.2 °C (±0.36 °F) ACCURACY OVER TEMPERATURE RANGE HMT100 remote probe and wall mount models. Features/Benefits ▪ ▪ ▪ Full 0 ... 100 %RH measurement Two-wire loop-powered or three-wire voltage output configurations Fixed and remote probe models The Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT100 are designed for humidity and temperature monitoring in demanding environments. Typical applications include stability rooms, HVAC, livestock farms, greenhouses, indoor swimming pools, and outdoor applications. ▪ ▪ Display available ▪ ▪ Vaisala HUMICAP® sensor ▪ ▪ Different output scalings Available options Compatible with hand-helds HM70 and HMI41 for calibration ▪ ▪ IP65 (NEMA 4) housing The HMT100 is available as a wall mount or remote probe model with an optional display. For high temperature applications or where space is limited, the remote probe is ideal. 28 Relative humidity, dewpoint, temperature outputs Interchangeable probe module for minimal maintenance downtime NIST traceable (certificate included) Performance HMT100 incorporates Vaisala HUMICAP® technology that measures relative humidity accurately and reliably. Vaisala HUMICAP® is also resistant to dust and most chemicals. HMT100 can show relative humidity only, dewpoint only, or relative humidity and temperature, or dewpoint and temperature readings. The probes are interchangeable without having to calibrate or adjust the transmitter. HMT100 can also be installed outdoors using an installation kit, or directly into an air conditioning channel using a duct installation kit. Annual calibration Calibration is recommended typically at an interval of one year using either the Vaisala HUMICAP® Hand-held Humidity and Temperature Meter HM70 or the Vaisala HUMICAP® Humidity Indicator HMI41. The accuracy of the instrument can also be checked using the Vaisala Humidity Calibrator HMK15, which is based on saturated salt solutions. 4 ... 20 mA 10 ... 35 VDC (RL = 0 ohms) 20 ... 35 VDC (RL = 500 ohms) Voltage output signals 0 ... 1 V, 0 ... 5 V, 0 ... 10 V (0 ... X V see order form) Supply voltage 10 ... 35 VDC/24 VAC Current consumption, 35 VDC/24 VAC max. 12 mA External load RL min. 10 kΩ Mechanics Material Housing ABS/PC plastic Probe chrome coated aluminum Mounting plate GM45160 ABS plastic Housing classification IP65 (NEMA 4) Sensor protection Plastic grid DRW010522 Plastic grid with membrane filter DRW010525 Sintered stainless steel filter HM46670SP Connections screw terminals 0.5 ... 1.5 mm2 Probe cable lengths 3 m, 5 m, 10 m Calibration with HM70, HMI41, or with internal 11 %RH & 75 %RH buttons Display option One line fixed variable or changing variables when two variables are ordered Options and accessories Temperature sensor Pt1000 IEC 751 1/3 class B DEWPOINT TEMPERATURE (CALCULATED) Measuring range -20 ... +80 °C (-4 ... +176 °F) Operating Environment Operating temperature range transmitter body, no display transmitter body, with display probe (remote probe only) Storage temperature range Electromagnetic compatibility -40 ... +60 °C (-40 ... +140 °F) -30 ... +60 °C (-22 ... +140 °F) -40 ... +80 °C (-40 ... +176 °F) -40 ... +60 °C (-40 ... +140 °F) EN61326-1, Industrial Environment For more information, visit www.vaisala.com or contact us at [email protected] Spare probe Spare extension cable (10 m) Radiation shield Rain shield with installation kit Installation plate Duct installation kit Connection cable for HMI41 Connection cable for HM70 HMP100 DRW220095 DTR502B 215109 DRW010699 215619 2591722 211339 Ref. B210472EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 29 DMW19 Wall Mount Dewpoint Transmitters for Indoor Applications Technical data Dewpoint temperature Operating environment 'HZSRLQWWHPSHUDWXUH& Measurement range Accuracy The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 is an easy and fast way to confirm the performance of DMW19 on site. Vaisala HUMICAP® Dewpoint Transmitter DMW19 is a compact wall mount dewpoint transmitter. Features/Benefits ▪ Designed for demanding building automation applications and other wall mount indoor applications where dewpoint measurement is needed ▪ Dewpoint measurement range -20 ... +55 °C (-4...+131 °F) ▪ ▪ Accuracy ±2 °C (±3.6 °F) ▪ 30 Vaisala HUMICAP® Sensor for excellent accuracy and long-term stability, negligible hysteresis and resistance to dust and most chemicals. Electronic, on site, one-point field check with Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 The wall mount Vaisala HUMICAP® Dewpoint Transmitter DMW19 is designed for use in air conditioning and other indoor wall mount applications where accurate and stable dewpoint measurement is required. DMW19 is an ideal choice for demanding building automation applications where dewpoint is the preferred parameter for humidity measurement. Proven Vaisala HUMICAP® Sensor Technology The operation of DMW19 is based on the proven Vaisala HUMICAP® Sensor. The dewpoint is calculated from relative humidity and temperature. The patented Vaisala HUMICAP® Sensor is insensitive to dust, particulate dirt and most chemicals. This results in high accuracy, excellent long-term stability and negligible hysteresis. -20 ... +55 °C (-4 ... +131 °F) ±2 °C (±3.6 °F) (see graph below) 5LVNRIFRQGHQVDWLRQ Operating temperature Storage temperature Relative humidity -5 ... +60 °C (+23 ... +140 °F) -40 ... +80 °C (-40 ... 176 °F) 0 ... 95 %RH operating and storage Electromagnetic compatibility Complies with EMC standard EN61326-1, Generic Environment $FFXUDF\&7G Dimensions Dimensions in mm $FFXUDF\QRWVSHFLILHG 3URFHVVWHPSHUDWXUH& Dewpoint accuracy vs. measurement conditions Response time 15 s Humidity sensor Vaisala HUMICAP® 180 Temperature sensor Pt 100 IEC 751 1/3 class B 33 (1.30) 85 (3.35) Operating environment Operating temperature Storage temperature Relative humidity -5 ... +60 °C (+23 ... +140 °F) -40 ... +80 °C (-40 ... 176 °F) 0 ... 95 %RH operating and storage 1 1 0 ( 4 .3 3 ) www.vaisala.com Outputs Analog outputs (scalable) Easy to install DMW19 is compact and lightweight. In addition, DMW19 is easy to install and it is suitable for different junction boxes. Fast, on-site field check The accuracy of the transmitter is simple to check on-site using the Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70. DMW19 is suitable for demanding building automation and other wall mount indoor dewpoint measurements. Resolution for current output Resolution for voltage output Typical temperature dependence 4 ... 20 mA 0 ... 1 V 0 ... 5 V 0.002 mA 0.3 mV 0.005 % of span/ °C General Operating voltage with voltage output 12 ... 35 VDC 11 ... 28 VAC Operating voltage with current output 20 ... 35 VDC / 19 ... 28 VAC with RL500 ohm 17 ... 35 VDC / 16 ... 28 VAC with RL50 ohm Supply current 10 mA + load current Load for voltage output min. 10 kohm Load for current output max. 500 ohm Connections screw terminals 0.5 ... 1.5 mm2 Housing ABS plastics Housing colour NCS-2502-R Housing classification IP33 Weight 110 g For more information, visit www.vaisala.com or contact us at [email protected] HUMICAP® is a registered trademark of Vaisala. Ref. B210394EN-B ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 31 www.vaisala.com HMD60/70 Humidity and Temperature Transmitters for ducts in HVAC applications Features/Benefits ▪ ▪ ▪ ▪ ▪ ® Vaisala HUMICAP Humidity and Temperature Transmitters HMD60 and HMD70 are designed for use in air conditioning applications where accurate and stable control of relative humidity and temperature are required. The duct mounted Vaisala HUMICAP® Humidity and Temperature Transmitters HMD60 and HMD70 are designed for monitoring relative humidity and temperature in building energy management systems. The combination of high accuracy, stability and reliable operation, make these products the ideal choice for demanding applications. Measures both humidity and temperature Resistant to chemicals and dust The accuracy of the transmitters is simple to check using either the Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 or the Vaisala HUMICAP® Humidity Indicator HMI41. The calibration can be done in seconds with a single potentiometer without disturbing the operation, resulting in great savings both in maintenance time and costs. The duct mount HMD60 and HMD70 transmitters can also be used in many industrial humidity monitoring applications, where their stability and resistance to chemicals and dust are of great value. A useful feature of these duct mount transmitters is the ability to remove the electronics without removing the unit from the duct. 32 The HMD60 and HMD70 transmitters are available in three models: U for humidity measurement-only, Y for humidity and temperature measurement, and T for temperature only. ▪ ▪ ▪ ▪ Full 0 ... 100 %RH measurement Technical data 60 series: 2-wire, 4 to 20 mA output Duct mount Selectable signal output of 0 ... 1 V, 0 ... 5 V or 0 ... 10 V (HMD70) with optional current module also 0 ... 20 mA (HMD70) Vaisala HUMICAP® Sensor for excellent accuracy and long-term stability, negligible hysteresis and resistance to dust and most chemicals. Output signal Supply voltage range depends on the selected output signal DC AC 0 ... 1V 10 ... 35 V 9 ... 24 V 0 ... 5 V 14 ... 35 V 12 ... 24 V 0 ... 10 V 19 ... 35 V 16 ... 24 V RH only RH & T T only HMD70U HMD70Y HMD70T Relative humidity Measurement range duct mount Accuracy at +20 °C 0 ... 100 %RH* %RH 3 2 1 0 -1 0 10 20 30 40 50 60 70 80 90 WITH OPTIONAL CURRENT MODULE 0 ... 20 mA (RL = 0 ohm) 10 ... 35 V **0 ... 20 mA (RL = 500 ohm) 20 ... 35 V Power consumption @ 24 VAC HMD70U HMD70Y 11 ... 24 V 17 ... 24 V 10 mA typical 12 mA typical 100 %RH General -2 -3 Temperature dependence %RH 2.0 -20 °C, + 1,5 % 1.5 1.0 0.5 0 -20 -10 0 10 -0.5 +80 °C, + 1,3 % 20 30 40 50 60 70 80 °C -1.0 -1.5 -2.0 Response time at +20 °C (+68 °F), 90% response Stability Sensor 15 s (with membrane filter) + 2 %RH / 2 years HUMICAP® 180 Temperature (Y and T models) Linearity Sensor Measurement range Accuracy better than 0.1 °C Pt 1000 IEC 751 class B -20 ... +80 °C (-4 ... 176 °F) ** Operating temperature range electronics -5 ... +55 °C (+23 ... +131 °F) probe -20 ... +80 °C (-4 ... +176 °F) Storage temperature range -40 ... +80 °C (-40 ... +176 °F) Maximum flow speed 50 m/s Current module part no. 18945 HM Housing probe stainless steel electronics cast aluminum Connections screw terminals 0.5 ... 1.5 mm2 Sensor protection standard membrane filter (part no. DRW010525) optional stainless steel sintered filter (part no. HM46670SP) Cable thread-through bushing for 7 ... 10 mm (PG9) cable housing IP65 (NEMA 4) part no. 18941HM armoured cable glands part no. 10528HM (must be ordered separately) 0.8 Complies with EMC standard EN61326 and EN55022 0.6 Fast, on-site calibration 10 ... 35 VDC (RL = 0 ohm) 20 ... 35 VDC (RL = 500 ohm) 4 ... 20 mA General - 70 series IP65 (NEMA 4) housing NIST traceable (certificate included) Supply voltage Duct mount Temperature compensated Also available as temperatureonly transmitters HMD 60T/70T HMD60U HMD60Y HMD60T 70 series: 3-wire, variable voltage output Accuracy up to ±2 %RH True two-wire transmitters with 4 ... 20 mA loop powered output (HMD60) General - 60 series RH only RH & T T only 0.4 0.2 0 -20 -10 0 10 20 30 40 50 60 70 80 -0.2 -0.4 -0.6 -0.8 ** Optional temperature scales are available on request. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210839EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 33 www.vaisala.com HMW60/70 Humidity and Temperature Transmitters for wall mounting in HVAC applications Technical data 60 series: 2-wire, 4 to 20 mA output Wall mount General - 60 series RH only RH & T T only HMW60U HMW60Y HMW60T Supply voltage 10 ... 35 VDC (RL = 0 ohm) 20 ... 35 VDC (RL = 500 ohm) 4 ... 20 mA Output signal 70 series: 3-wire, variable voltage output General - 70 series Wall mount Supply voltage range depends on the selected output signal DC AC 0 ... 1V 10 ... 35 V 9 ... 24 V 0 ... 5 V 14 ... 35 V 12 ... 24 V 0 ... 10 V 19 ... 35 V 16 ... 24 V Power consumption @ 24 VAC HMW70U 10 mA typical HMW70Y 12 mA typical RH only RH & T T only HMW70U HMW70Y HMW70T Relative humidity Measurement range Accuracy at +20 °C 0 ... 95 %RH* %RH 3 2 General 1 0 0 -1 10 20 30 40 50 60 70 80 90 100 %RH -2 -3 Temperature dependence %RH +55, + 0,5 % -5 °C, + 1 % 1.0 0.5 0 ® Vaisala HUMICAP Humidity and Temperature Transmitters HMW60 and HMW70 are designed for use in air conditioning applications where accurate and stable control of relative humidity and temperature are required. Features/Benefits ▪ ▪ Accuracy up to ±2 %RH ▪ Selectable signal output of 0 ... 1 V, 0 ... 5 V or 0 ... 10 V (HMW70) ▪ ▪ ▪ ▪ 34 True two-wire transmitters with 4 ... 20 mA loop powered output (HMW60) Vaisala HUMICAP® Sensor for excellent accuracy and long-term stability, negligible hysteresis and resistance to dust and most chemicals. Temperature compensated Also available as temperatureonly transmitters HMW 60T/70T NIST traceable (certificate included) The wall mounted Vaisala HUMICAP® Humidity and Temperature Transmitters HMW60 and HMW70 are designed for monitoring relative humidity and temperature in building energy management systems. The combination of high accuracy, stability and reliable operation, make these products the ideal choice for demanding applications. Measures both humidity and temperature The HMW60 and HMW70 transmitters are available in three models: U for humidity measurement-only, -10 0 10 20 30 40 50 60 °C -0.5 -1.0 Y for humidity and temperature measurement, and T for temperature only. Fast, on-site calibration The accuracy of the transmitters is simple to check using either the Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 or the Vaisala HUMICAP® Humidity Indicator HMI41. The calibration can be done in seconds with a single potentiometer without disturbing the operation, resulting in great savings both in maintenance time and costs. Response time at +20 °C (+68 °F), 90 % response 15 s Stability +2 %RH / 2 years Sensor HUMICAP® 180 * Output signal corresponds to 0 ... 100 %RH Operating temperature range electronics Storage temperature range Long-term humidity range for electronics Housing material IP Class 30 Fire resistance Colour Connections -5 ... +55 °C (+23 ... +131 °F) -40 ... +80 °C (-40 ... +176 °F) 0 ... 85 %RH ABS plastic UL94-HB NCS-2502-R screw terminals 0.5 ... 1.5 mm2 Complies with EMC standard EN61326 and EN55022 Temperature (Y and T models) Linearity Sensor Measurement range Accuracy' better than 0.1 °C Pt 1000 IEC 751 class B -5 ... +55 °C (+23 ... 131 °F) ** 0.5 0.4 0.3 0.2 0.1 0 -10 0 10 20 30 40 50 60 -0.1 -0.2 -0.3 -0.4 -0.5 ** Optional temperature scales are available on request. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210840EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 35 www.vaisala.com HMW40/50 and HMD40/50 Wall and Duct Mount Transmitters for HVAC Applications Technical data Relative humidity Measurement range (for which accuracy is specified) Operating range HMD40/50 HMW40/50 Accuracy at +20 °C (+68 °F) Stability Temperature dependence Sensor 10 ... 90 %RH 0 ... 100 %RH 0 ... 90 %RH better than ±3 %RH ±2 %RH over 2 years <±1.5 %RH from -10 ... +60 °C (+14 ... 140 °F) INTERCAP® Sensor, part no. 15778HM Temperature (40Y and 50Y) In energy management systems, the accurate measurement of relative humidity and temperature is essential for optimum control of the environment. Vaisala INTERCAP ® Humidity and Temperatur e Transmtters HMD/W40/50 are competitively priced and require no routine maintenance – a smart choice for your HVAC/EMC applications. Features/Benefits ▪ Specially designed for building energy management systems ▪ ▪ 10 ... 90 %RH measurement ▪ -5 ... +55 °C (+23 ... +131 °F) operating range for wall units ▪ 4 ... 20 mA 2-wire output (HMD/W40) ▪ Selectable voltage 3-wire output (HMD/W50) ▪ Combines excellent stability with easy installation and reliable operation ▪ ▪ No recalibration ▪ Low cost 36 -10 ... +60 °C (+14 ... +140 °F) operating range for duct units Fully interchangeable Vaisala INTERCAP® Sensor is easy to replace The two and three-wire Vaisala INTERCAP® Humidity and Temperature Transmitters HMD/W40 and HMD/W50 are designed for use in energy management systems in buildings. They combine excellent stability with easy installation and reliable operation. The HMD40/50 are for duct installations and the HMW40/50 for wall installations. Low maintenance costs The HMD40/50 humidity transmitters use Vaisala INTERCAP® Sensor the world’s first interchangeable capacitive humidity sensor. The transmitters require no recalibration if the sensor is changed. This means great savings in overall maintenance costs. The sensor is also insensitive to dust as well as most chemicals. Measures both humidity and temperature The 40/50 series is available as humidity and temperature (Y), or humidity only (U) transmitters. The transmitters measure humidity with a ±3 %RH accuracy and a ±1 %RH stability per year. Measurement range HMD40/50 HMW40/50 Total accuracy at +25 °C Temperature dependence Sensor -10 ... +60 °C (+14 ... +140 °F) -5 ... +55 °C (+23 ... +131 °F) ±0.3 °C (±0.54 °F) 0.01 °C/°C (0.01 °F/°F) Pt 1000 IEC 751 class B Power supply HMD/W40 HMD/W50 10 ... 28 VDC for 0 ... 1 V output: 12 ... 35 VDC/12 ... 24 VAC for 0 ... 10 V output: 15 ... 35 VDC/15 ... 24 VAC Electromagnetic compatibility: Complies with EN61326-1, Generic Environment Current consumption HMD/W50 6 mA typical Operating temperature range HMD40/50 -10 ... +60 °C (+14 ... +140 °F) HMW40/50 -5 ... +55 °C (+23 ... +131 °F) Storage temperature range -40 ... +60 °C (-40 ... +140 °F) Operating humidity range HMD40/50 0 ... 100 %RH HMW40/50 0 ... 90 %RH Housing Material ABS plastic Classification (HMD40/50) IP65(NEMA 4) Colour(HMW40/50) NCS0502-G50Y General Dimensions Output signal for relative humidity (equals 0...100 %RH) HMD/W40 4 ... 20 mA HMD/W50 0 ... 1 V & 0 ... 10 V Output signal for temperature HMD/W40 4 ... 20 mA HMW50 0 ... 1 V & 0 ... 10 V HMD50 0 ... 10 V HMD40Y, HMD50Y equals -40 ... +60 °C (-40 ... 140 °F) HMW40Y, HMW50Y equals -5 ... +55 °C (+23 ... 131 °F) Dimensions in mm. HMW40/50 HMD40/50 Selectable functions (HMD/W50) The HMD/W50 transmitters feature selectable output signals of 0 to 1 V and 0 to 10 V. They can be powered by either AC or DC voltage. INTERCAP® is a registered trademark of Vaisala For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210945EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 37 www.vaisala.com HMM210 Series Humidity Modules for Environmental Chambers relative humidity and temperature or dewpoint measurement with various configurations. All modules have microprocessor based electronics and are equipped with analog or digital outputs. Unique warmed probe The warmed probe and composite sensor, available on the dewpoint probe configuration, is warmed to always remain a few degrees higher than ambient. Advantages of this patented technique include: r /PDPOEFOTBUJPOQSPCMFNTPOUIF probe, as the temperature of the probe always remains higher than the ambient. Vaisala HUMICAP® Humidity and Temperature Module Series HMM210 provide fast real-time measurement in a wide temperature range.The modules are especially suitable for demanding OEM applications, e.g. environmental chambers and incubators. Features/Benefits ▪ ▪ Three probe configurations: ▪ Dewpoint probe with probe heating. By heating the whole probe a few degrees above ambient condensation is avoided. Relative humidity (RH) plus temperature (T) probe. ▪ Dewpoint probe described above, together with a temperature probe for obtaining relative humidity and temperature outputs. ▪ ▪ Three module configurations ▪ Chemical purge option maintains high measurement performance in demanding chemicalconditions. ▪ Calibration certificate included 38 Different probe and cable lengths The Vaisala HUMICAP® Humidity and Temperature Module Series HMM210 are designed for OEM type applications needing humidity or dewpoint measurement in demanding environments, e.g. in environmental chambers growth chambers and incubators. Demanding applications The HMM210 modules are optimized for harsh environments with both high humidities and a wide temperature range. The humidity measurement is fully temperature compensated. In addition, the modules remain accurate and reliable under extreme conditions where a combination of high humidity and rapidly changing temperature can result in condensation on the sensor head. The modules are highly versatile and flexible. They provide either r 'BTUSFTQPOTFUJNFFTQFDJBMMZJO rapidly changing temperatures. r *NQSPWFETUBCJMJUZBOEBDDVSBDZJO high humidities. Vaisala HUMICAP® Sensor and chemical purge option The HMM210 modules use Vaisala HUMICAP®180R sensors for best possible stability. The sensor is insensitive to dust and to most chemicals. In conditions of extraordinary high levels of chemicals and cleaning agents, chemical purge is available as an option. With chemical purge, contaminants are evaporated from the sensor and performance is returned to normal. Technical data Relative Humidity General Measurement range Accuracy (including non-linearity, hysteresis and repeatability) 0 ... 100 %RH +2 %RH (0 ... 90 %RH) +3 %RH (90 ... 100 %RH) Response time (90 % at +20 °C/+68 °F) in still air (with sintered filter) 60 s Typical temperature dependence of electronics 0.02 %RH/°C (0.02 %RH/°F) Humidity sensor HUMICAP®180R Temperature Measurement range -70 ... +180 °C (-94 ... +356 °F) +0.1 °C (+0.18 °F) Typical accuracy of electronics at +20 °C Typical temperature dependence of electronics 0.0025°C/°C (0.0025 °F/°F) Temperature sensor in RH+T probe: HMM211 and HMM213 Pt 100 RTD IEC 751 1/3 Class B HMM212 Pt 1000 RTD IEC 751 1/3 Class B Additional temperature probe Pt 100 RTD IEC 751 1/4 Class B Outputs Two analog outputs selectable HMM211 HMM212 Digital output HMM213 0 ... 1 V, 0 ... 5 V, 0 ... 10 V 0 ... 20 mA 4 ... 20mA (loop powered) RS232 Operating temperature range Probe -70 ... +180 °C (-94 ... +356 °F) Electronics -5 ... +55 °C (+23 ... +131 °F) Storage temperature range (Electronics) -40 ... +70 °C (-40 ... +158 °F) Sensor protection (standard) stainless steel sintered filter Connections screw terminals for 0.5 ... 1.5 mm2 wires Power Supply Operating voltage 10 ... 35 VDC In modules with analog outputs the supply range depends to a certain extent on the selected output range. Current consumption without sensor head warming or re-gaining option HMM211 & HMM213 12 mA at 35 VDC Configuration Options Compatible with modules: PROBES HMM211 HMM212 HMM213 RH+T Dewpoint (heated composite sensor) Temperature yes yes yes yes yes yes yes CABLE LENGTHS RH+T and Dewpoint probes Temperature probe CHEMICAL PURGE 65, 150 and 300 cm 150 and 300 cm Automatically takes place at power-up HUMICAP® is a registered trademark of Vaisala. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210901EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 39 www.vaisala.com HMM100 Humidity Module for Environmental Chambers Technical data Performance Mechanics RELATIVE HUMIDITY Service cable connector Probe diameter Probe cable lengths Probe material plastics stainless steel Probe mounting clamp Mounting bracket material lid bottom plate Module housing material Measurement range 0 ... 100 %RH Accuracy (incl. non-linearity, hysteresis and repeatability) temperature range -20 ... +40 °C 0 ... 90 %RH ±2 %RH 90 ... 100 %RH ±3 %RH temperature range -40 ... -20 °C, +40 ... +180 °C 0 ... 90 %RH ±2.5 %RH 90 ... 100 %RH ±3.5 %RH Factory calibration uncertainty (+20 °C) ±1.5 %RH Humidity sensor Vaisala HUMICAP® 180R M8 series 4-pin (male) 12 mm 0.6/1.55/2.9 m PPS AISI316/PPS AISI316 ABS/PC Al ABS/PC (cover) DEW POINT TEMPERATURE Measurement range -20 ... +100 °C (-4 ... +212 °F)Td Accuracy (incl. non-linearity, hysteresis and repeatability when dew point depression <20 °C ±2 °C Td (Ambient temperature - dew point) Operating environment The Vaisala HUMICAP® Humidity Module HMM100. Features/Benefits The HMM100 ▪ The Vaisala HUMICAP® Humidity Module HMM100 is an open frame module for integration into environmental chambers. The modules provide a single analog output channel for relative humidity (RH) or dewpoint (Td). ▪ ▪ Full temperature compensation over the operating temperature range of -70˚C ... +180˚C High temperature tolerance, also suitable for heatsterilization Easy to install Robust and reliable Applications: test chambers, incubators The HMM100 probe works in freezing conditions (-70 °C) and also in temperatures up to +180 °C. The Accessories The accessories available are a component board mounting bracket with a lid, probe clamp, USB-cable for service use, a module housing and a probe mounting flange. 1.93 49 Input and outputs 1.21 30.7 Operating voltage 2-wire model 3-wire model 24 VDC 10 ... 35 VDC or 24 VAC 15 ... 35 VDC or 24 VAC when 0 ... 10 V output is used Power consumption 6 mA Analog output types (1 output selectable) 2-wire model 4 ... 20 mA (loop-powered) 3-wire model 0 ... 20 mA, 0 ... 1 V/5 V/10 V Max. wire size 0.5 ... 1. 5 mm2 (AWG) Service port M8 connector for USB cable For more information, visit www.vaisala.com or contact us at [email protected] 40 2.12 54 1.83 46.5 Maintenance-free 2.17 55 0.14 3.5 ▪ ▪ ▪ Easy field calibration by trimmers See Table AW 7 [0.28] Durable Compared to psychrometers, the HMM100 is practically maintenancefree. There is no wick that needs changing and there is no need for a water tank or water pump. Thus, environmental stress screening can be done reliably. HUMICAP180R 10159HM 6221 219452SP HM47280SP 225979 226060 226061 226067 226068 Dimensions 0.47 12 ▪ ▪ Two probes are available, one made of plastics, the other of stainless steel. Several cable lengths up to 3 meters are available. Both the probes have the Vaisala HUMICAP® 180R sensor which ensures excellent measurement accuracy. Maintenance-free Humidity sensor Membrane filter Plastic grid filter Porous PTFE filter Stainless steel sintered filter Mounting bracket with lid Module housing (IP65) Probe mounting flange Probe mounting clamp set (10 pcs) USB cable 1.44 36.5 Excellent measurement accuracy with Vaisala HUMICAP® 180R sensor HMM100 is easy to install and the probe can be freely placed in a test chamber as the speed of airflow does not affect the measurement. Operating temperature range component board -5 ... +55 °C (+23 ... +131 °F) stainless steel and plastic probe -70 ... +180 °C (-94 ... +356 °F) porous PTFE filter stainless steel, sintered filter -70 ... +180 °C (-94 ... +356 °F) plastic grid, membrane filter -20 ... +80 °C (-4 ... +176 °F) Electromagnetic compatibility Complies with EMC standard EN61326-1, for use in light industrial environments Options and accessories Ref. B210813EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 41 Performance RELATIVE HUMIDITY Measurement range Typical accuracy temperature range 0 ... 90 %RH 90 ... 100 %RH temperature range 0 ... 90 %RH 90 ... 100 %RH Humidity sensor 0 ... 100 %RH 0 ... +40 °C ±3 %RH ±5 %RH -40 ... 0 °C, +40 ... +60 °C ±5 %RH ±7 %RH Vaisala INTERCAP® TEMPERATURE Measurement range Accuracy over temperature range -40 ... +60 °C -40 ... +60 °C ±0.6 °C DEW POINT Measurement range -40 ... +60 °C Typical accuracy temperature range 0 ... +40 °C when dew point depression < 15 °C ±2 °C temperature range -40 ... 0 °C, +40 ... +60 °C when dew point depression < 10 °C ±3 °C dew point depression = ambient temperature - dew point The HMP60 for extreme conditions. Features/Benefits HMP60 Several outputs ▪ ▪ ▪ The HMP60 is a simple, durable and cost-effective humidity probe. It is suitable for volume applications, integration into other manufacturers’ equipment, incubators, glove boxes, greenhouses, fermentation chambers, and data loggers. There are two configurable voltage outputs with relative humidity, temperature or dew point scaling. Four voltage output ranges are available. Miniature-size humidity probe Low power consumption Measurement range: 0 ... 100 %RH; -40 ... +60°C ▪ Cable detachable with standard M8 connector ▪ ▪ Rugged metal housing Easy installation Interchangeable Vaisala INTERCAP® Sensor ▪ Optional RS485 digital output The probe cable has a screw-on quick connector for easy installation. Different cable lengths are available. Also other compatible M8 series cables can be used. Accessories are available for different installation needs. Optional dew point output ▪ 42 Applications: volume applications, integration into other manufacturers’ equipment, glove boxes, greenhouses, fermentation chambers, data loggers Low current consumption The HMP60 is suitable for batterypowered applications because of its very low current consumption. Rugged design The HMP60 is designed for extreme conditions. The aluminum body of the HMP60 is classified as IP65. The probe has a sealed structure and the sensor is protected by a membrane filter and a plastic grid, or optionally by a stainless steel filter. Recalibration not needed The Vaisala INTERCAP® Sensor is interchangeable. No recalibration is required; the sensor can simply be replaced, also in the field. Operating environment Operating temperature Electromagnetic compatibility -40 ... +60 °C Complies with EMC standard EN61326-1, Basic immunity test requirements Inputs and outputs Operating voltage (Use lowest available operating voltage to minimize heating.) 5 ... 28 VDC / 8 ... 28 VDC with 5 V output 8 ... 28VDC with loop power converter 1 mA average, max. peak 5 mA <14 V: 1 s; >14 V: 4 s Current consumption Start-up time at operating voltage Outputs 2 channels 0 ... 1 VDC/0 ... 2.5 VDC / 0 ... 5 VDC/1 ... 5 VDC 1-channel loop-power converter (separate module, compatible with humidity accuracy only) 4 ... 20 mA digital output (optional) RS485 2-wire half duplex For more information, visit www.vaisala.com or contact us at [email protected] External loads 0 ... 1 V 0 ... 2.5 V /0 ... 5 V RL min 10 kΩ RL min 50 kΩ Mechanics Materials body grid filter cable Housing classification Body thread Cable connector Weight with 0.3 m cable chrome coated aluminum chrome coated ABS plastic polyurethane or FEP IP65 MI2x1 / 10 mm 4-pin M8 (IEC 60947-5-2) 23 g Options and accessories Vaisala INTERCAP® Sensor, 1 piece Vaisala INTERCAP® Sensor, 10 pcs Sensor protection plastic grid membrane filter stainless steel sintered filter 4 ... 20mA loop power converter Mounting bracket with lid Plastic M12 installation nuts, pair USB cable for PC connection Probe mounting clamp set, 10 pcs Probe mounting flange Connection cables 0.3 m PU 3 m PU 180°C 3 m FEP 15778HM INTERCAPSET-10PCS DRW010522 DRW010525 HM46670SP UI-CONVERTER-1 225979 18350SP 219690 226067 226061 HMP50Z032 HMP50Z30A 226902 Dimensions in mm (inches) (2.8) 71 (0.47) 12 Vaisala INTERCAP® Humidity and Temperature Probe HMP60 Technical data M12 x1 www.vaisala.com Ref. B210851EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 43 www.vaisala.com Technical data Vaisala HUMICAP® Humidity and Temperature Probe HMP110 Performance Start-up time at operating voltage RELATIVE HUMIDITY Measurement range 0 ... 100 %RH Accuracy (incl. non-linearity, hysteresis and repeatability) temperature range 0 ... +40 °C 0 ... 90 %RH ±1.7 %RH 90 ... 100 %RH ±2.5 %RH temperature range -40 ... 0 °C, +40 ... +80 °C 0 ... 90 %RH ±3.0%RH 90 ... 100 %RH ±4.0%RH Factory calibration uncertainty (+20 °C) ± 1.5%RH Humidity sensor Vaisala HUMICAP® 180R Stability ±2 %RH over 2 years Outputs 2 channels <14 V: 1 s >14 V: 4 s 0 ... 1 VDC/0 ... 2.5 VDC / 0 ... 5 VDC/1 ... 5 VDC 1-channel loop-power converter (separate module, compatible with humidity accuracy only) digital output (optional) External loads 0 ... 1 V 0 ... 2.5 V /0 ... 5 V 4 ... 20 mA RS485 2-wire half duplex RL min 10 kΩ RL min 50 kΩ TEMPERATURE Measurement range -40 ... +80 °C Accuracy over temperature range 0 ... +40 °C, ±0.2 °C -40 ... 0 °C, +40 ... +80 °C ±0.4 °C Temperature sensor Pt1000 RTD 1/3, Class B IEC 751 DEW POINT The HMP110 with excellent stability and high chemical tolerance. Features/Benefits HMP110 Several outputs ▪ Miniature-size humidity transmitter ▪ Low power consumption and fast startup for battery powered applications The temperature measurement is a standard feature, dew point measurement is optional. Three standard voltage outputs are available. ▪ Measurement range: 0 ... 100 %RH; -40 ... +80°C ▪ Cable detachable with standard M8 quick connector ▪ The HMP110 is a trouble-free and cost-effective humidity transmitter with high accuracy and good stability. It is suitable for volume applications or integration into other manufacturers’ equipment. The HMP110 is also suitable for glove boxes, greenhouses, fermentation and stability chambers, data loggers, and incubators. Reliable: Latest generation HUMICAP® 180R sensor for best stability and high chemical tolerance. IP65 metal housing. ▪ ▪ Optional RS485 digital output Traceable: Comes with calibration certificate. ±1.7%RH measurement accuracy (0 ... 90%RH) ▪ HMP110R replacement probe service available for easy maintenance ▪ Optional dew point calculation 44 Easy installation The probe cable has a screw-on quick connector for easy installation. Different cable lengths and accessories are available. Low current consumption HMP110 is suitable for batterypowered applications because of its very low current consumption. It also has a fast start-up time. Robust design The aluminum body of the HMP110 is classified as IP65. Thus, it survives rough conditions. The HMP110 has high chemical tolerance because of the HUMICAP® 180R sensor. Easy maintenance Maintaining measurement traceability is easy using the HMP110R replacement probe. We send you a replacement probe, you detach the old probe and send it back to us. In this way the measurement is available at all times without interruptions. Measurement range -40 ... +80 °C Accuracy (incl. non-linearity, hysteresis and repeatability) temperature range 0 ... +40 °C when dew point depression < 15 °C ±1 °C when dew point depression 15 ... 25°C ±2 °C temperature range -40 ... 0 °C, +40 ... +80 °C when dew point depression < 15 °C - dew point ±2 °C depression = ambient temperature - dew point Operating environment Measurement range Electromagnetic compatibility -40 ... +80 °C Complies with EMC standard EN61326-1, Basic immunity test requirements Inputs and outputs Operating voltage (Use lowest available operating voltage to minimize heating) Current consumption 5 ... 28 VDC / 8 ... 28 VDC with 5 V output 8 ... 28VDC with loop power converter 1 mA average, max. peak 5 mA For more information, visit www.vaisala.com or contact us at [email protected] Mechanics Materials body grid filter cable Housing classification Body thread Cable connector Weight with 0.3 m cable chrome coated aluminum chrome coated ABS plastic polyurethane or FEP IP65 MI2x1 / 10 mm 4-pin M8 (IEC 60947-5-2) 23 g Options and accessories Sensor protection plastic grid membrane filter stainless steel sintered filter 4 ... 20mA loop power converter Mounting bracket with lid Plastic M12 installation nuts, pair USB cable for PC connection Probe mounting clamp set, 10 pcs Probe mounting flange Connection cables standard 0.3 m standard 3 m 80 °C 1.5 m 80 °C 3 m 180 °C 3 m FEP DRW010522 DRW010525 HM46670SP UI-CONVERTER-1 225979 18350SP 219690 226067 226061 HMP50Z032 HMP50Z30A 225777SP 225229SP 226902 Ref. B210852EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 45 www.vaisala.com HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications Technical data HMP75, HMP76 and HMP77 probes Measured variables MI70 measurement indicator Indicator general RELATIVE HUMIDITY Menu languages Measurement range 0 ... 100 %RH Accuracy (including nonlinearity, hysteresis and repeatability) at +15 ... +25 °C (+59 ... +77 °F) ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) at -20 ... +40 °C (-4 ... +104 °F) ±(1.0 + 0.008 x reading) %RH at -40 ... +180 °C (-40 ... +356 °F) ±(1.5 + 0.015 x reading) %RH Factory calibration ±0.6 %RH (0 ... 40 %RH) uncertainty (+20 °C / +68 °F) ±1.0 %RH (40 ... 97 %RH) (Defined as ±2 standard deviation limits.) Response time (90%) at +20 °C (+68 °F) in still air HMP75 (with standard plastic grid) 17 s HMP76 (with standard sintered bronze filter) 60 s HMP77 (with standard plastic grid and stainless 50 s steel netting) Sensor HUMICAP® 180R ® HUMICAP 180RC (chemical purge, sensor preheat) Typical long-term stability better than 1 %RH / year TEMPERATURE The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 is a highperformance, portable humidity reference that is exciting to use. Features/Benefits ▪ ▪ ▪ ▪ Multilingual user interface Shows measurement trends graphically Proven Vaisala HUMICAP® Sensor technology 3 probe alternatives, temperature measurement ranges between -70 and +180 °C ▪ Multiprobe operation; dewpoint and CO2 probes can also be connected ▪ 2 probes can be connected simultaneously ▪ Displays various humidity parameters ▪ Sensor preheat and chemical purge options for demanding conditions ▪ 46 NIST traceable (certificate included) ® The Vaisala HUMICAP Hand-Held Humidity and Temperature Meter HM70 is designed for demanding humidity measurements in spotchecking applications. It is also ideal for field checking and calibration of Vaisala's fixed humidity instruments. The HM70 incorporates the latest generation of the Vaisala HUMICAP® Sensor. It is reliable and has better than ever long-term stability. Additionally, it has a sensor that copes well with chemical interference and provides accuracy that lasts in demanding conditions. The chemical purge option maintains measurement accuracy in environments with high concentrations of chemicals. The sensor preheat option reduces measurement delays as it keeps the sensor dry when the probe is inserted into hot and humid processes. Three probes to choose from The HMP75 is a general purpose probe whereas the HMP76 is a long, stainless steel probe especially suitable for spot-checking in ducts. The HMP77 is a small probe at the end of a 5-meter cable. The probe is ideal for difficult-to-reach areas and for on-site calibration of Vaisala's process transmitters. In addition, the HM70 supports the use of Vaisala's dewpoint, carbon dioxide and moisture in oil probes, allowing measurements in several multiparameter applications. MI70 Link The optional MI70 Link Windows® software and the USB connection cable form a practical tool for transferring logged data and real time measurement data from the HM70 to a PC. Measurement range HMP75 HMP76 short time HMP77 Accuracy at +20 °C (+68 °F) Accuracy over temperature range -20 ... +60 °C (-4 ... +140 °F) -50 ... +120 °C (-58 ... +248 F) -50 ... +180 °C (-58 ... +356 °F) -70 ... +180 °C (-94 ... +356 °F) ±0.2 °C (±0.36 °F) (see graph) °C 0.7 0.6 0.5 0.4 0.3 0.2 0.1 °C 0 -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -80 -60 -40 -20 0 20 Temperature sensor 40 60 80 100 120 140 160 180 Pt100 IEC751 1/3 class B Probe general Operating temperature range for electronics -40 ... +60 °C (-40 ... +140 °F) Housing classification IP65 (NEMA 4) Housing material ABS/PC blend Probe material Stainless steel (AISI316L) Cable length between probe and indicator 1.9 m For more information, visit www.vaisala.com or contact us at [email protected] English, Chinese, French, Spanish, German, Russian, Japanese, Swedish, Finnish Display LCD with backlight, graphic trend display of any parameter, character height up to 16 mm Max. no. of probes 2 Power supply Rechargeable NiMH battery pack with ACadapter or 4xAA-size alkalines, type IEC LR6 0 Analog output 0... 1 VDC Output resolution 0.6 mV PC interface MI70 Link software with USB or serial port cable Data logging capacity 2700 points Alarm audible alarm function Operating temperature range -10 ... +40 °C (+14 ... +104 °F) Operating humidity range non-condensing Housing classification IP54 Battery operation time Continuous use 48 h typical at +20 °C (+68 F) Data logging use up to a month, depending on logging interval Electromagnetic Complies with EMC standard compatibility EN61326-1, Portable Equipment MI70 indicator + probe = HM70 ACCESSORIES Carrying cases for MI70 and HMP75/77 probe for MI70 and HMP75/76 probe Transmitter connection cables for HMT330 & HMT100 Series HM60/70/140 Series MI70 Link software with USB cable MI70 Link software with serial port cable Analog output cable Sensor protection HMP75 Plastic PC grid (HMP75 standard) Membrane filter Sintered bronze filter HMP76/77 Plastic PPS grid Sintered stainless steel filter Sintered bronze filter (HMP76 standard) PPS grid with SS netting (HMP77 standard) MI70CASE MI70CASE2 211339 HMA6070 219687 MI70LINK 27168ZZ 6221 10159HM DRW212987SP DRW010276SP HM47280SP DRW212987SP DRW010281SP Ref. B210435EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 47 www.vaisala.com HMI41 Indicator and HMP46 High Temperature Probe The Vaisala HUMICAP® Humidity Indicator HMI41 fitted with the Vaisala HUMICAP® Humidity and Temperature Probe HMP46 can be used for spot checking humidity and temperature in ducts or chambers. Typical applications are plant maintenance, installation and inspection of air conditioning systems, production and storage areas and production processes. In addition, it is suitable for field checking Vaisala's humidity transmitters. Withstands high temperatures The Vaisala HUMICAP® Humidity Indicator HMI41 equipped with the Vaisala HUMICAP® Humidity and Temperature Probe HMP46 is an ideal combination for spot checking and field calibration. The HMP46 operates in full humidity range of 0 ... 100 %RH. The temperature range is from -40 to +100 °C (-40 ... +212 °F). For short periods of time, the probe can withstand temperatures up to +180 °C (+356 °F). The HMP46 probe is solid and rugged. Its stainless steel probe is made to withstand rough handling in mechanically demanding applications. The probe’s long shaft can also reach otherwise unreachable places. Versatile and easy to use In addition to displaying the humidity and temperature readings, the HMI41 indicator calculates dewpoint and wet bulb temperature, absolute humidity and mixing ratio. The indicator has an easy-to-read two line liquid crystal display. The display units (metric or non-metric) are easily selected. Technical data HMI41 indicator TEMPERATURE Calculated variables Features/Benefits ▪ RH measurement range 0 ... 100 %RH ▪ Temperature measurement range -40 ... +100 °C (-40 ... +212 °F), for short periods up to +180 °C (+356 °F) ▪ ▪ ▪ Calculates dewpoint, wet bulb temperature, absolute humidity and mixing ratio Versatile and easy-to-use Incorporates Vaisala HUMICAP® Sensor ▪ ▪ ▪ Excellent stability ▪ Optional carrying case and calibration cable ▪ Available as a complete calibration kit HMK41 Data collection with serial line NIST traceable (certificate included) These features, plus fast response time, high measurement accuracy and excellent stability, as well as the wide temperature range of the probe, make the HMI41/HMP46 combination an ideal choice for the most demanding applications. High performance sensor The HMP46 probe incorporates Vaisala HUMICAP® Sensor. This sensor has high accuracy, excellent long-term stability and negligible hysteresis. In addition, the sensor is insensitive to dust, particulate dirt and most chemicals. dewpoint temperature, absolute humidity, wet bulb temperature, mixing ratio 0.1 %RH; 0.1 °C/°F 4 batteries, type AA (LR 6) Resolution Power supply Battery operation time (alkaline batteries) 72 h continuous use Auto-off function Operating temperature -20 ... +60 °C (-4 ... +140 °F) Storage temperature -40 ... +70 °C (-40 ... +158 °F) Display two line LCD Housing material ABS plastic Housing classification IP53 (with connectors blocked) Weight (incl. batteries) 300 g Maximum measurement error of indicator at +20 °C humidity ±0.1 %RH temperature ±0.1 °C (±0.18 °F) # Temperature sensor 4 # Pt 100 IEC 751 1/3 class B HMP46 probe General HUMIDITY Typical ranges of calculated variables dewpoint temperature -20 ... +100 °C (-4 ... +100 °F) absolute humidity 0 ... 600 g/m3 wet bulb temperature 0 ... 100 °C (32 ... 212 °F) mixing ratio 0 ... 600 g/kg d.a. The accuracies of these calculated variables are limited by the accuracies of the measured variables on which they are based, namely RH and T. The RH and T accuracies are stated under HMP46 probe. Measurement range 0 ... 100 %RH, non-condensing Accuracy (incl. nonlinearity, hysteresis and repeatibility) at +20 °C Maximum achievable accuracy when calibrated against high quality, certified humidity standards: 0 ... 90 %RH ±1 %RH 90 ... 100 %RH ±2 %RH When calibrated against salt solutions (ASTM E104-85) 0 ... 90 %RH ±2 %RH 90 ... 100 %RH ±3 %RH Temperature Dependence ERROR2( FORTEMPORARY USEONLY 4 # Typical long-term stability Response time (90%) at +20 °C in still air w/sintered filter Humidity sensor better than 1 %RH per year 15 s HUMICAP® 180 For more information, visit www.vaisala.com or contact us at [email protected] 48 Continuous measurement -40 ... +100 °C (-40 ... +212 °F) Short-term measurement -40 ... +180 °C (-40 ... +356 °F) Accuracy at +20 °C (+68 °F) ±0.2 °C (±0.36 °F) Accuracy over the measurement range Cable length 1500 mm; extended spiral cable Operating temperature range for electronics -20 ... +60 °C (-4 ... +140 °F) Housing material Electronics housing ABS plastic Probe stainless steel Housing classification electronics IP65 (NEMA 4) Sensor protection sintered filter, part no. 0195 optionmembrane filter, part no. 10159HM (max +80 °C / +176 °F) plastic grid, part no. 6221 (max +80 °C / +176 °F) Weight 450 g Electromagnetic compatibility Complies with EMC standard EN61326-1, Portable Equipment Ref. B210940EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 49 www.vaisala.com HMP41, HMP42 and HMP45 Probes for HMI41 Indicator Vaisala HUMICAP® Humidity Indicator HMI41 can be used with any one of the four probes to quickly and easily measure humidity and temperature, and to make other measurement calculations such as dewpoint, wet bulb temperature, absolute humidity and mixing ratio. The HMI41 indicator with the HMP41 probe. The HMI41 has an easy-to-read LCD display. Temperature readout is available in either degrees Centigrade or Fahrenheit. Calculated variables are available in metric and nonmetric format. Ideal for spot checking applications The HMI41 indicator with probes is ideal for use in a variety of spot checking applications such as plant maintenance, air-conditioning system installation and inspection, freezers and storage and production areas. Vaisala HUMICAP® Humidity and Temperature Probe HMP41: HMI41 with the HMP42 probe. HMI41 with the HMP45 probe. 50 HMP41, HMP42, and HMP45 probes HUMIDITY Features/Benefits ▪ Humidity measurement range 0 ... 100 %RH ▪ Temperature measurement range HMP41, HMP45: -20 ... +60 °C (-4 ... +140 °F) HMP42: -40 ... +100 °C (-40 ... +212 °F) ▪ For spot checking measurements ▪ ▪ Versatile and easy-to-use ▪ Extremely thin 4 mm probe head (HMP42) ▪ Incorporates Vaisala HUMICAP® Sensor, which provides high accuracy, excellent long-term stability, neglible hysteresis, and insensitivity to dust and most chemicals ▪ The HMI41 Indicator can be used with any of the four available probes NIST traceable (certificate included) r JOUJHIUQMBDFT r JOEVDUTPSDIBNCFST This probe is fix-mounted directly on the HMI41 indicator. It can be upgraded to an HMP45 by purchasing the HMH45 handle and cable option. r VOEFSBMJOPMFVNGMPPS Vaisala HUMICAP® Humidity and Temperature Probe HMP42: Vaisala HUMICAP® Humidity and Temperature Probe HMP45: The HMP42 probe can be used for spot checking humidity and temperature in applications which require an extremely thin probe, such as: This probe for general purposes features an extended spiral cable. r GPSNPOJUPSJOHUIFESZJOHPG structures during construction or after water damage Technical data The probe diameter is only 4 mm, allowing access into very small, tight, and hard-to-reach spaces. Vaisala HUMICAP® Humidity and Temperature Probe HMP46: See preceding data sheet. Measurement range 0 ... 100 %RH Accuracy at +20 °C (+68 °F) when calibrated against salt ±2 %RH (0 ... 90 %RH) solutions (ASTM E014-85) ±3 %RH (90 ... 100 %RH) Temperature dependence of electronics ±0.05 %RH/°C Typical long-term stability better than 1 %RH per year Response time (90%) at +20 °C in still air (HMP41, HMP45) 15 s (HMP42) 30 s Sensor HMP41 & 45 HUMICAP® 180 Sensor HMP42 HUMICAP® MINI TEMPERATURE Measurement range probe HMP41, HMP45 -20 ... +60 °C (-4 ... +140 °F) HMP42 -40 ... +100 °C (-40 ... +212 °F) Temperature accuracy over measurement range Sensor (HMP41 & 45) PT 1000 IEC 751 1/3 class B (HMP 42) PT 100 IEC 751 class B Battery operation time (alkaline batteries) 72 h continuous use Housing material ABS plastic Housing classification, electronics IP65 (NEMA 4) Sensor protection HMP41 & 45 plastic grid HM46717 option membrane filter 2787HM HMP42 steel grid 19867HM membrane tube set (5pcs) 19858HM Weight HMP41 30 g HMP42 200 g HMP45 160 g Electromagnetic compatibility Complies with EMC standard EN61326-1, Portable Equipment. Accessories Serial interface cable Carrying case for HMI41 and HMP41/45 Aluminum case for HMP41/42/45/46 Rigid plastic case for HMP41/42/45/46 HMP42 Calibration adapter Rubber sleeve set 19446ZZ HM36736 MI70CASE2 210614 HM37067 19809HM Dimensions Dimensions in mm. HMI41 HMP41 HMP42 HMP45 30 30 General 38 88 Typical ranges of calculated variables dewpoint temperature -20 ... +60 °C (-4 ... +140 °F) absolute humidity 0 ... 160 g/m3 wet bulb temperature 0 ... +60 °C (32 ... +140 °F) mixing ratio 0 ... 160 g/Kg d.a. The accuracies of these calculated variables are limited by the accuracies of the measured variables on which they are based, namely RH and T. The RH and T accuracies are stated above in the probe section. Cable length (HMP42 & 45) 1500 mm; extended spiral cable Operating temperature range HMP41 -20 ... +60 °C (-4 ... +140°F) HMP42 -40 ... +100 °C (-40 ... +212 °F) HMP45 -40 ... +60 °C (-40 ... +140 °F) For more information, visit www.vaisala.com or contact us at [email protected] 118 Ø 18.5 Ø 18.5 Ø 21 237 13 318 106 200 125 75 80 3 7 HUMICAP® is a registered trademark of Vaisala. Ref. B210941EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 51 www.vaisala.com Technical data HM34 Pocket Size Relative Humidity Meter The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM34 provides a fast and convenient way to accurately spot-check relative humidity and temperature. Fast and easy-to-use In measurement mode, the extendable probe just slides out. Normally, measurement takes only a few seconds. The HM34 meter includes a HOLD button which allows the user to retain an RH or T measurement until it has been noted or recorded. ▪ Ideal for spot checking humidity levels ▪ ▪ ▪ Measurement range 0 ... 100 %RH Incorporates Vaisala HUMICAP® Sensor that provides high accuracy, excellent long-term stability, neglible hysteresis, and insensitivity to dust and most chemicals ▪ Temperature measurement range -20 ... +60 °C (-4 ... +140 °F) ▪ ▪ Available in either °F or °C Lightweight, pocket-sized ▪ Each unit comes with a 9V battery, attached probe, 0.2 μm protective membrane filter and a carrying case ▪ ▪ ▪ Fast response with ±2% accuracy Extendable probe Automatic POWER-OFF Display Hold function Power supply Battery operation time Automatic POWER OFF Response time (90%) After the measurement is completed, the probe is slid back into the meter casing. Between spot checks, the meter is normally stored in its carrying case. Features/Benefits General Measurement range Accuracy 0 ... 100 %RH ±2% (0 ... 90 %RH) ±3% (90 ... 100 %RH) Resolution 0.1 %RH Temperature dependence ±0.04 %RH/°C Sensor type HUMICAP®H thin film capacitive sensor If no buttons are pressed for three minutes, the unit automatically switches itself off. This automatic POWER-OFF function prevents the possibility of accidental discharge of the HM34’s battery. Features/Benefits Relative humidity 15 s with membrane filter 5 s with plastic grid Temperature Range Accuracy Resolution Temperature dependence Sensor -20 ... +60 °C (-4 ... +140 °F) ±0.3 °C (±0.54 °F) 0.1 °C (0.1 °F) ±0.02 °C/°C (±0.02 °F/°F) Pt 100 IEC 751 1/3 Class B The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM34 provides accurate spot checks of humidity and temperature. NIST traceable (certificate included) For more information, visit www.vaisala.com or contact us at [email protected] 52 3 1/2 digit LCD Push-button hold of displayed value 9 V battery 50 h after 3 minutes, unless HOLD is activated Operating temperature range -20 ... +60 °C (-4 ... +140 °F) Housing ABC plastic Sensor protection standard plastic grid, part no. 6221 optional sintered filter 133 mm, part no. 0195 Weight 180 g with battery Ordering Information HM34C with °C temperature reading HM34F with °F temperature reading Electromagnetic compatibility Complies with EMC standard EN61326-1, Portable Equipment Ref. B210909EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 53 www.vaisala.com Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 and HMT130 Features/Benefits The HMT120/130 with and without a display. The Vaisala HUMICAP® Humidity and Temperature Transmittersw HMT120 and HMT130 are designed for humidity and temperature monitoring in cleanrooms and are also suitable for demanding HVAC applications. Performance The HMT120/130 incorporates Vaisala HUMICAP® technology that measures relative humidity accurately and reliably. The Vaisala HUMICAP® is resistant to dust and most chemicals. The transmitter enclosure is optimized for use in cleanrooms. The smooth surface of the enclosure makes it easy to clean and the enclosure material is chosen to tolerate purifying agents. Furthermore, the cabling can be done through the back wall of the transmitter. Interchangeable Probe The HMT120/130 transmitters use a fully interchangeable relative humity probe. The probe can be easily removed and replaced with a new one without having to adjust the transmitter, which allows for easy and quick recalibration of the transmitter. The probe can be adjusted using one of Vaisala’s portable meters as a reference. Also available is a constant output probe with fixed RH and T output for convenient inspection of the monitoring system and signal transfer line. ▪ Vaisala HUMICAP® technology with humidity sensor HUMICAP® 180R ▪ 2-wire loop-powered or 3-wire voltage output configurations ▪ Interchangeable probe (easy field calibration) ▪ ▪ Accurate and reliable ▪ ▪ Optional LCD display ▪ Wall-mounted or with a remote probe ▪ Constant output probe available ▪ Can be mounted outdoors using a Vaisala installation kit and the Vaisala Radiation Shield DTR502B ▪ ▪ Enclosure IP65 Resistant to dust and most chemicals USB cable available for a PC connection for maintenance Suitable for cleanrooms and demanding HVAC applications Available Options The HMT120 and HMT130 transmitters are available as wall mounted or with remote probe. For high temperature applications or where space is limited, the remote probe is ideal. The transmitters come with an optional, LCD display, which shows the measurement results of selected parameters in selected units. The parameters are displayed simultaeously at two separate rows on the display. Technical Data Performance Mechanics RELATIVE HUMIDITY Material transmitter housing display window probe body probe grid filter Housing classification Connections inputs and outputs probe interface Probe cable lengths Display (optional) Measurement range -40 °C ... +80 °C Accuracy over temperature range at +15 °C ... +25 °C ±0.2 °C at 0 ... +15 °C and at +25 °C ... +40 °C ±0.25 °C at -40 °C ... +0 °C and at +40 °C ... +80 °C ±0.4 °C Temperature sensor Pt1000 RTD 1/3 Class B IEC 751 Operating temperature range transmitter body, no display -40 °C ... +60 °C transmitter body, with display -20 °C ... +60 °C HMP110 probe -40 °C ... +80 °C Storage temperature range -50 °C ... +70 °C Electromagnetic compatibility EN 61326-1 and EN 55022 Inputs and outputs HMT120 TWO-WIRE TRANSMITTER (LOOP POWERED) Current output signals External loop voltage 4 ... 20 mA 10 ... 30 VDC (RL= 0 ohms) 20 ... 30 VDC (RL< 500 ohms) HMT130 THREE-WIRE TRANSMITTER 0 ... 1 V, 0 ... 5 V, 0 ... 10 V or user defined between 0 ... 10 V Min output resistance 1 kohm Serial output RS485, non-isolated Relay output 1 relay (max. 50 VDC, 200 mA) Supply voltage 10 ... 35 VDC 15 ... 35 VDC (when output 0 ... 10 V) 24 VAC (±20 %) Current consumption at 24 VDC 8 mA, if relay closed 15 mA Max. additional error caused by the analog outputs after calibration at +20 °C ambient temperature ±0.1 % of FS output signal Temperature dependence of the analog outputs ±0.005 % of FS output signal Screw terminals 0.5 ... 1.5 mm2 4-pin M8 female panel connector 3 m, 5 m, 10 m - up to 50 m 128 x 64 resolution full graphics B&W display without backlight 270 g Weigth (including probe) Accessories Humidity and temperature probe Humidity and temperature replacement probe Constant output probe Humidity sensor Probe mounting flange Probe mounting clamps, 10 pcs HMP110 sensor protection plastic grid filter plastic grid with membrane filter stainless steel sintered filter Probe cable 3 m Probe cable 5 m Probe cable 10 m Radiation shield Probe installation kit for DTR502 Rain shield with installation kit Duct installation kit HMI41 connection cable HM70 connection cable USB serial interface cable * See separate order form HMP110* HMP110R* HMP110REF* HUMICAP® 180R 226061 226067 DRW010522SP DRW010525 HM46670SP HMT120Z300 HMT120Z500 HMT120Z1000 DTR502B 210623 215109 215619 25917ZZ 211339 219685 116 120 Wall Assembly dimensions 78 M4 ;4 pc s 39 46 92 72 Voltage output signals PBT plastic PC plastic Chrome coated aluminum Chrome coated ABS plastic IP65 91 TEMPERATURE 145 Measurement range 0 ... 100 %RH Accuracy including non-linearity, hysteresis, and repeatability at 0 °C ... +40 °C ±1.7 %RH (0 ... 90 %RH) ±2.5 %RH (90 ... 100 %RH) at -40 °C ... +0 °C and ±3.0 %RH (0 ... 90 %RH) at +40 °C ... +80 °C ±4.0 %RH (90 ... 100 %RH) Factory calibration uncertainty at +20 °C (+68 °F) ±1.5 %RH Humidity sensor Vaisala HUMICAP® 180R For more information, visit www.vaisala.com or contact us at [email protected] Ref. B211086EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com Technical data HMK15 Humidity Calibrator accepted and reliable method to calibrate humidity instruments. Usually two or three different salt solutions are used. Salts are chosen according to the application. three step plugs to fit all chamber holes (12 mm, 13.5 mm and 18.5 mm) transit covers for secure transportation and long-term storage Certified salts The HMK15 can be ordered with certified and pre-measured salts. A sample calibration is made from each batch in Vaisala’s Measurement Standards Laboratory (MSL). General Options The standard HMK15 consists of the following parts: Certified and ready dosed salts: Order code: Total uncertainty*: LiCl salt 11 %RH MgCl2 salt 33 %RH NaCl salt 75 %RH 97 %RH K2SO4 salt *Uncertainties given at +20 °C 19729HM 19730HM 19731HM 19732HM (±1.3%RH) (±1.2%RH) (±1.5%RH) (±2.0%RH) Two salt chambers, chamber covers and transit covers Base plate Choice of thermometers mercury thermometer,Vaisala calibrated, order code 19728HM thermometer with red capillary liquid, calibrated by manufacturer, order code 25130HM Measurement cup and mixing spoon on exchanged water Extra salt chambers Carrying bag 19767HM 19766HM HM27032 Calibrated thermometer thermometer with calibration certificate In addition to laboratory use,Vaisala Humidity Calibrator HMK15 is suitable for onsite checks of humidity probes and transmitters. Features/Benefits No measuring instrument stays accurate by itself. It is essential that the functioning of an instrument is periodically checked against a reference. Vaisala has developed the Vaisala Humidity Calibrator HMK15 to make calibration and spot checking of humidity probes and transmitters easy and reliable. ▪ Easy and reliable calibration of humidity probes and transmitters ▪ Based on saturated salt solutions ▪ ▪ ▪ Fast temperature equilibration Suitable for laboratory use and on-site checks Method used by leading laboratories ▪ Chambers and transit covers make HMK15 easy to transport ▪ Pre-measured certified salts available ▪ Vaisala Service Centers offer accredited calibrations for humidity, temperature and barometric pressure. The operating principle of the HMK15 is based on the fact that a saturated salt solution generates a certain relative humidity in the air above it. The reading of the humidity probe or transmitter can then be adjusted accordingly. Many leading laboratories use this generally 54 No external power required The HMK15 can be ordered with a thermometer, which is used for measuring the temperature during the calibration. It can also be used for checking the temperature measurement accuracy of the transmitter. The thermometer can contain either mercury (accuracy ±0.3 °C (±0.54 °F)) or red capillary fluid (accuracy ±1.0 °C (±1.8 °F)). FINAS approved Measurement Standards Laboratory Vaisala’s Measurement Standards Laboratory is a FINAS accredited calibration laboratory. FINAS is a member of the EA (the European Cooperation for Accreditation). For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210908EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 55 www.vaisala.com HMP155 Humidity and Temperature Probe Technical data Performance General RELATIVE HUMIDITY Features/Benefits HMP155 with a new, stable HUMICAP®180R sensor and an additional temperature probe. New probe for reliability The new Vaisala HUMICAP® Humidity and Temperature Probe HMP155 provides reliable humidity and temperature measurement. Long-term stability The HMP155 has a new generation Vaisala HUMICAP®180R sensor that has excellent stability and withstands well harsh environments. The probe structure is solid and the sensor is protected with a sintered teflon filter, which gives maximum protection against liquid water, dust, and dirt. Warmed probe and high humidity environment This is an environment to which Vaisala has designed a patented, warmed probe for reliable measuring. As the sensor head is warmed continuously, the humidity level inside it stays below the ambient level. Thus, it also reduces the risk of condensation forming on the probe. Fast temperature measurement What’s more, with its fast response time, the additional temperature probe for the HMP155 is ideal for measurement in environments with changing temperatures. ▪ Vaisala HUMICAP®180R sensor - superior long-term stability ▪ Optional warmed humidity probe ▪ ▪ ▪ ▪ Plug-and-play ▪ ▪ ▪ Weather-proof housing IP66 ▪ Applications: meteorological applications, aviation and road weather, instrumentation Chemical purge USB connection for service use Installation kits for DTR13 and DTR502 radiation shields and also for a Stevenson screen New, fast temperature probe Different output possibilities: voltage, RS-485, resistive Pt100 Long lifetime Protecting the sensor from scattered and direct solar radiation, and precipitation will increase its lifetime. Thus, Vaisala recommends installing the HMP155 in one of the following radiation shields: DTR503, DTR13, or a Stevenson screen. Easy maintenance The probe can be calibrated using a pc with a USB cable, with the push buttons, or with the MI70 indicator. Measurement range Accuracy (incl. non-linearity, hysteresis and repeatability) at +15 ... +25 °C (+59 ... +77 °F) 0 ... 100 %RH ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) -20 ... +40 °C (-4 ... 104 °F) ±(1.0 + 0.008 x reading) %RH -40 ... -20 °C (-40 ... -4 °F) ±(1.2 + 0.012 x reading) %RH +40 ... +60 °C (+104 ... +140 °F) ±(1.2 + 0.012 x reading) %RH -60 ... -40 °C (-76 ... -40 °F) ±(1.4 + 0.032 x reading) %RH Factory calibration ±0.6 %RH (0 ... 40 %RH)* uncertainty (+20 °C /+68 °F) ±1.0 %RH (40 ... 97 %RH)* * Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate. Recommended humidity sensor HUMICAP®180R(C) Response time at +20 °C in still air with a sintered PTFE filter 63 % 20 s 90 % 60 s TEMPERATURE Measurement range -80 ... +60 °C (-112 ... +140 °F) Accuracy with voltage output at -80 ... +20 °C ±(0.226 - 0.0028 x temperature) °C +20 ... +60 °C ±(0.055 + 0.0057 x temperature) °C passive (resistive) output according to IEC 751 ±(0.1 + 0.00167 x |temperature|)°C 1/3 Class B RS485 output -80 ... +20 °C ±(0.176 - 0.0028 x temperature) °C +20 ... +60 °C ±(0.07 + 0.0025 x temperature) °C Accuracy over temperature range (opposite) Temperature sensor Pt100 RTD 1/3 Class B IEC 751 Response time with additional temperature probe in 3 m/s air flow 63 % <20 s 90 % <35 s OTHER VARIABLES Operating temperature range Storage temperature range Connection Connection cables Cable material Wire size Service cables -80 ... +60 °C (-112 ... +140 °F) -80 ... +60 °C (-112 ... +140 °F) 8-pin male M12 connector 3.5, 10, and 30 m PUR AWG26 USB connection cable MI70 connection cable Additional T probe cable length 2m Housing material PC Housing classification IP66 Sensor protection sintered PTFE Weigth (probe) 86 g Electromagnetic compatibility: Complies with the EMC standard EN61326-1, Electrical equipment for measurement control and laboratory use - EMC requirement for use in industrial locations Inputs and outputs Operating voltage 7 ... 28 VDC* *Note: minimum operating voltage 12 V with 0 ... 5 V output and 16 V with 0 ... 10 V output, probe heating, chemical purge or XHEAT. Outputs voltage output 0 ... 1 V, 0 ... 5 V, 0 ... 10 V resistive Pt100 (4-wire connection) RS485 Average current consumption (+15 VDC, load 100 kOhm) 0 ... 1 V output <3 mA 0 ... 10 V output +0.5 mA RS485 <4 mA during chemical purge max. 110 mA with warmed probe max. 150 mA Settling time at power-up voltage output 2s RS485 3s ǻ ºC 0.5 dewpoint/frost point temperature, wet bulb temperature, mixing ratio 0.4 0.3 0.2 0.1 ºC 0 -0.1 -0.2 -0.3 -0.4 -0.5 -80 -60 -40 -20 RS485 output Measuring humidity reliably is challenging in environments where humidity is near saturation. Measurements may be corrupted by fog, mist, rain, and heavy dew. A wet probe may not give an accurate measurement in the ambient air. 56 For more information, visit www.vaisala.com or contact us at [email protected] 0 20 40 60 voltage output Ref. B210752EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 57 www.vaisala.com DTR500 Solar Radiation and Precipitation Shields The special plastic used in the plates has excellent thermal characteristics; the white outer surface reflects radiation; the black inside absorbs accumulated heat. The shields can be easily installed on either a vertical pole, horizontal beam, or a flat surface. Dimensions in mm. DTR502B for HMT337, HMT100 and PTU300 DTR503A for HMP155 (ø105) (ø105) r 7BJTBMB)6.*$"1® Humidity and Temperature Probe HMP155 r7BJTBMB)6.*$"1® Humidity and Temperature Transmitter HMT337 Choice of models and installation accessories (266) r7BJTBMB)6.*$"1® Humidity and Temperature Transmitter HMT100 (437) The maintenance-free DTR500 series shields protect the humidity and temperature sensors from solar radiation and precipitation. They provide excellent ventilation while blocking both direct and reflected solar radiation. Dimensions Dimensions in mm. (200) Shield protects sensor The DTR Shields can be used with the following Vaisala probes: Dimensions (361) The Vaisala Radiation Shield Series DTR500 are solar radiation and precipitation shields support humidity probe installations in outdoor applications. Technical data Two models are available: r/JOFQMBUFTIJFME Vaisala Radiation Shield DTR502B for HMT337, HMT100, PTU300 and HMP155's additional T probe (213) r5XFMWFQMBUFTIJFME Vaisala Radiation Shield DTR503A for HMP155 DTR502B pole mast installation. (233) DTR503A pole mast installation. The Vaisala Solar Radiation Shield Series DTR500 are available in either a 9 or 12-plate, model. Features/Benefits ▪ Protects temperature and humidity probes from scattered, as well as, direct solar radiation and rain. ▪ Installs easily on a vertical pole, horizontal beam or flat surface ▪ Maintenance-free ▪ Suitable for a wide range of applications ▪ Naturally ventilated ▪ Choice of shields and mounting accessories 58 DTR502B horizontal beam installation. DTR503A horizontal beam installation. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210906EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 59 HMD60UO/YO Outdoor Humidity and Temperature Transmitter & Solar Radiation Shield Features/Benefits ▪ Vaisala Solar Radiation Shield DTR503B provides excellent ventilation while blocking direct and reflected solar radiation, and precipitation True two-wire transmitter with 4 to 20 mA loop powered output: compatible with most energy management systems ▪ Electromagnetically compatible ▪ ▪ ▪ Temperature compensated ® Vaisala HUMICAP Humidity and Temperature Transmitter HMD60YO, combined with Vaisala Solar Radiation Shield DTR503B is easy to install and ideal for outdoor applications. Full 0 … 100 %RH measurement Excellent long-term stability General Temperature (Y and T models only) Supply voltage 10 ... 35 VDC (RL = 0 ohms) 20 ... 35 VDC (RL = 500 ohms) 4 ... 20 mA Output signal Operating temperature range electronics sensor head Storage temperature range Connections Housing sensor head electronics housing Sensor protection optional Operating range -40 … +60 °C (-40 … +140 °F) s# 0.8 0.6 0.4 -40 … +60 °C (-40 … +140 °F) -40 … +60 °C (-40 … +140 °F) -40 ... +80 °C (-40 ... +176 °F) screw terminals 0.5 ... 1.5 mm2 0.2 0 -20 -10 0 10 Stable performance in demanding outside environments The duct-mount Vaisala HUMICAP® Humidity and Temperature Transmitters HMD60UO and HMD60YO utilize Vaisala HUMICAP® Sensor. The Vaisala HUMICAP® Sensor is known for its excellent reliability, long-term stability, and reliable operation in humidity measurement. In addition, the sensors are insensitive to dust and most chemicals, and are not damaged by condensation. The transmitters feature two wire connections that make retrofitting, upgrading and installations easy. Fast, on-site calibration The accuracy of the transmitters is easy to check by using Vaisala HUMICAP® Hand-Held Humidity Meter 60 Shield protects sensor The maintenance-free, 12 plate Vaisala Solar radiation Shield DTR503B is naturally ventilated, and protects the sensors from scattered, as well as, direct solar radiation and rain. The plates are composed of a special plastic material that offers excellent thermal characteristics and UV stabilized construction. The white outer surface reflects radiation, while the black inside absorbs accumulated heat, resulting in more accurate measurement. 30 40 50 60 70 80 s# -0.4 -0.6 -0.8 stainless steel cast aluminum membrane filter stainless steel sintered filter Relative humidity Output signal Accuracy Linearity Sensor -40 … +60 °C (-40 … +140 °F) better than 0.1 °C (0.18 °F) PT 1000 IEC 751 class B Dimensions HMD60U AND HMD60Y Dimensions in mm Measurement range Accuracy at +20 °C (+68 °F) 0 ... 100 %RH (ø105) DTR503B dimensions %RH 3 2 1 Negligible temperature coefficient ▪ ±2 % accuracy (0...90 %RH), ±3 % (90 % ... 100 %RH) ▪ NEMA 4 (IP65) housing 0 -1 0 10 20 30 40 50 60 70 80 90 100 %RH -2 -3 Pole Mast, diameter 30...60 mm / 1,2...2,3" Temperature dependence Response time at +20 °C (+68 °F) Sensor 15 s with membrane filter HUMICAP® 180 (285.5) %RH HM70. The calibration can be done in seconds with a single potentiometer – without disturbing the operation, thus ensuring accuracy and saving hours of maintenance time. 20 -0.2 (442) ▪ ▪ Technical data (266) www.vaisala.com Easy-to-install The easy-to-install DTR503B is suitable for a wide range of applications. It can be mounted on a vertical pole, horizontal beam or flat surface. HMD70UO/YO Versatile alternatives to the HMD60UO/YO transmitters for outdoor applications are the HMD70UO/YO transmitters. These instruments feature selectable output signals of 0 … 1V, 0 … 5V, or 0 … 10V or 0 … 20mA. Powered by either AC or DC voltage, they are available with relative humidity only, or relative humidity and temperature sensors. They are also equipped with the radiation/precipitation shield. 2pcs 2.0 1.5 DTR503B pole installation 1.0 0.5 0 -0.5 -20 0 20 40 60 80 •C -1.0 -1.5 -2.0 HUMICAP® is a registered trademark of Vaisala. DTR503B horizontal beam installation For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210768EN-B ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 61 www.vaisala.com Technical data HMT330MIK Meteorological Installation Kit Dimensions Dimensions in mm (inches) 13 SFHVMBSQSPCF XBSNFEQSPCF After a period of 100 % relative humidity, the warmed probe measures the true humidity, whereas the non-warmed probe takes time to recover from the condensation. The HMT337 and PTU307 feature warmed probe technology. Installed with the HMT330MIK kit either one forms the right choice for reliable humidity measurement in humid weather conditions. Features/Benefits ▪ For outdoor humidity and temperature measurements ▪ Can be ordered in a variety of configurations ▪ Used together with HMT337 transmitter or PTU307 ▪ Vaisala SPH 10/20 Static Pressure Head eliminates effectively pressure variations in the barometer caused by wind HMT337/PTU307 Features ▪ Warmed probe provides truehumidity readings in condensing conditions ▪ Humidity measurement expressed as relative humidity and/or dewpoint temperature ▪ Easy field calibration with the HM70 hand-held meter 62 The Vaisala Meteorological Installation Kit HMT330MIK enables the Vaisala HUMICAP® Humidity and Temperature Transmitter HMT337 to be installed outdoors to obtain reliable measurements for meteorological purposes. True humidity readings in condensing conditions In weather observations dew formation makes reliable humidity measurement difficult. When dew has formed on the humidity sensor, it is impossible to obtain a true reading until this dew evaporates. Both the PTU307 and HMT337 avoid this problem by warming the probe. When warmed, the relative humidity inside the probe stays below the ambient level. With an accurate temperature measurement, the ambient dewpoint can be calculated precisely. To obtain the ambient relative humidity, an additional probe measures the ambient temperature, and the transmitter calculates the relative humidity from the dewpoint and temperature values. Open shield prevents microclimates The warmed probe of the HMT337/ PTU307 is mounted in a shield which is open at the bottom to ensure steady air circulation to the sensor even in calm weather. In traditional radiation shields sleet or snow can accumulate on the shield and prevent the proper air circulation through the shield, and create a humid microclimate until the snow melts. Essential for critical weather measurements Obtaining a true humidity reading is particularly important e.g. in traffic safety: at airports and at sea as well as on the roads. It is essential, for example, in fog and frost prediction. d d Order form /++*,.,-%&"'!#*,1,("!!+,*" /++*,.,)!,!&.&*)-%&"'!#*, !!&.&*)'+,*"*,#*, )*)1,("!*,!+,*" /++*,.,(*/).&)$+'." !!&.&*)'.,)-(&..",(*/).&)$+'." ..& ,"--/,""! ! " %!! "$"$"#$$" %$!$# "&"!" ! %!! "$"&$ # "!" %!! "$"&$# "!" %!! "$"&$ # " &" "!" %!! "$"&$# " &" "!" ! %$!$ "#%!! "$""# ! "#$$" %$!$ "#%!! "$"##' "#$$" %$!$ "! ##' ! $$"##%" HUMICAP® is a registered trademark of Vaisala. For more information, visit www.vaisala.com or contact us at [email protected] For calibration, a portable HMP77 reference probe is easy to attach beside the HMT337 or PTU307 probe. Ref. B210944EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 63 HMT300TMK Turbine Mounting Kit for Power Turbine Intake Air Measurement cause errors in measurement. The patented warmed probe prevents condensation from forming on the sensor. Technical data Dewpoint temperature General Measurement range -40 ... +100 °C (-40 … +212 °F) Accuracy: find the intersection of the dewpoint temperature curve and the dewpoint difference reading (process temperature - dewpoint temperature) on the x-axis and read the accuracy in dewpoint measurement at the y-axis screw terminals for 0.5 mm2 wires (AWG 20), stranded wires recommended Operating voltage 24 VDC/VAC (20...28 V) or 115/230 VAC (Must be specified at time of order) Recommended external load for current outputs < 500 ohm 0...1 V output > 2 kohm (to ground) 0...5 & 0...10 V outputs > 10 kohm (to ground) Operating temperature range for electronics -40...+60 °C (-40 ... +140 °F) Storage temperature -55...+80 °C (-67 ... +176 °F) Housing material G-AlSi10 (DIN 1725) Housing classification IP65 (NEMA 4) Bushing 8...11 mm diameter cables (0.31 ... 0.43 inch) Humidity sensor protection (Ø 12 mm) PPS grid with steel netting Electromagnetic compatibility Complies with EMC standard EN61326-1, Industrial Environment www.vaisala.com Features/Benefits ▪ Designed for high humidity applications ▪ Measurement range: -40 ... +100°C ▪ ▪ Patented, warmed probe Incorporates Vaisala HUMICAP® Sensor for excellent accuracy and long-term stability and resistance to dust and most chemicals ▪ ▪ Low maintenance need ▪ NIST traceable (certificate included) 64 Outer cover provides protection from rain and direct sunlight Low maintenance Power turbines also require exact water vapor injection in the chamber to reduce pollutant emissions. Vaisala’s warmed probe technology is ideal because of its reliability in the field. In fact, the only suggested scheduled maintenance is annual calibration. Patented, warmed probe prevents condensation The HMT300TMK with the HMT337 installed, provides fast and reliable dewpoint measurement especially under high humidity conditions where dew would normally form on the humidity sensor and thereby Dimensions Dimensions in mm (inches) Typical accuracy of analog output at +20 °C (+68 °F) Typical temperature dependence of analog output Serial output available 0...20 mA, 4...20 mA, 0 ... 1 V, 0...5 V, 0 ... 10 V ±0.05 % full scale ±0.005 %/°C full scale RS232C (optional RS485) 254 (10) The HMT300TMK can be ordered separately for installation with the customer’s existing HMT337. 91.5 (3.6) 203 (8) .51) 165.3 (6.51) Ø 13 (0 HUMICAP® performance The HMT330 Series Transmitters are fitted with the latest generation of the HUMICAP®, the polymer sensor known for its accuracy, reliability and long-term stability. The sensor has a high tolerance for particulate abrasion and chemical contamination. Two standard outputs, third optional 20 s HUMICAP® 180C 101.6 (4) 193 (7.6) 488 (19.21) It is ideal for measuring in water vapor injection applications because the sensor has been optimized for high humidity environments by utilizing a patented, warmed probe. Water vapor is added to the intake of the turbine to increase the mass flow which in turn increases compression and electrical power output. Outputs 100 (3.94) The Vaisala HUMICAP Turbine Mounting Kit HMT300TMK is developed to monitor the air intake of gas and liquid fueled power turbines. Response time (90 %) at +20 °C (68 °F) in still air (PPS grid with steel netting) Sensor 144.5 (5.69) ® 441.5 (17.38) The Vaisala HUMICAP® Turbine Mounting Kit HMT300TMK is shown with the cover open. The outer cover protects the transmitter from direct sun light and rain. The installation kit protects the probe from outer water splashes, keeps the sensor dry, and prevents any parts that could vibrate loose from entering the turbine. The HMT300TMK includes a white, painted aluminum enclosure with an installation kit for the probe. The HMT337 Humidity and Temperature Transmitter is installed in the aluminum enclosure at the factory. The instrument can be equipped to be powered with either 24 VDC/VAC or with an internal 110/230 volt power supply unit. Protective enclosure Connections 100 (3.94) 354.9 (13.97) Vaisala HUMICAP® Humidity and Temperature Transmitter HMT337 The HMT337 is intended for demanding industrial humidity measurement applications with a risk of condensation. The stainless steel probe is mechanically durable and preferred for most industrial applications. HUMICAP® is a registered trademark of Vaisala. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210680EN-B ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 65 www.vaisala.com Vaisala INTERCAP® Humidity and Temperature Transmitter Series HMW80 The HMW80 combines excellent stability with easy installation and reliable operation. Features/Benefits ▪ Cost-efficient, dependable solution for humidity and temperature measurement for heating and ventilation ▪ Measurement range 0 ... 100 %RH and -5 ... +55 ˚C ▪ ▪ Stable and dependable ▪ ▪ ▪ ▪ Fits EU/US/JPN junction boxes Combines excellent stability with easy installation and reliable operation 2-year warranty No recalibration required UL-V0 approved materials used The two- and three-wire Vaisala INTERCAP® Humidity and Temperature Transmitter Series HMW80 is designed for use in energy management systems in buildings. They combine excellent stability with reliable operation. The HMW80 is easy to install: wire it to the terminal block at the transmitter bottom and close the housing with a snap-on lid to cover the electronics. Low Maintenance Costs The HMW80 humidity transmitters use the Vaisala INTERCAP® Sensor – an interchangeable capacitive humidity sensor. The transmitters require no recalibration if the sensor is changed. This means great savings in overall maintenance costs. The sensor is also insensitive to dust as well as to most chemicals. Measures Both Humidity and Temperature The HMW80 transmitters are available in four models: HMW82 and HMW83 transmitters measure both humidity and temperature. They measure humidity with a ±3 %RH accuracy and with a stability of ±3 %RH over 5 years. The accuracy of the temperature measurement is ±0.5 °C. Two other models, TMW82 and TMW83, measure temperature only. Both 2- and 3-wire transmitters are also available: HMW82 and TMW82 are 2-wire (4 … 20 mA loop powered) transmitters, and HMW83 and TMW83 are 3-wire (0 … 10 V) transmitters. Technical Data Performance Inputs and outputs Relative humidity Measurement range Accuracy Temperature range 30 ... 70 %RH Temperature range 0 ... 100 %RH Stability Humidity sensor HMW82, TMW82 0 ... 100 %RH 10 ... 30 °C ±3 %RH 0 ... 30 %RH, 70 ... 100 %RH ±5 %RH -5 ... +10 °C, +30 ... + 55 °C ±7 %RH ±3 %RH / 5 years Vaisala Intercap® Temperature Measurement range Accuracy +10 ... +30 °C -5 ... +10 °C, +30 ... +55 °C Temperature sensor -5 ... +55 °C ±0.5 °C ±1.0 °C Digital temperature sensor Outputs Loop resistance Supply voltage 4 ... 20mA, loop powered 0 ... 500 Ohm 10 ... 28 VDC HMW83, TMW83 Outputs Load resistance Supply voltage 0 ... 10V 10 kohm min 15 ... 35 VDC / 24 VAC ±20 % Mechanics IP class Housing colour Housing material IP30 RAL9003 ABS/PC UL-V0 approved Dimensions Operating environment Operating temperature range Storage temperature range Electromagnetic compliance -5 ... +55 °C -40 ... +60 °C complies with EMC standard EN61326-1, Light industrial Environment For more information, visit www.vaisala.com or contact us at [email protected] Ref. B211060EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com HMD42/53 Humidity and Temperature Transmitters for Ducts in Commercial HVAC Applications Features/Benefits The duct mounted Vaisala INTERCAP® Humidity and Temperature Transmitters HMD42 and HMD53 are designed for building automation applications. They combine reliable operation with excellent stability, providing low cost of ownership to the user. Flexibility in Humidity and Temperature Measurement The HMD42/53 transmitters measure humidity with a ±3 %RH accuracy and temperature with a ±0.4 °C (±0.72 °F) accuracy. They feature various selectable analog output signals and they can be powered by either AC or DC voltage. ▪ Designed for building automation applications ▪ ▪ ±3 %RH accuracy ▪ -20 ... +60 °C (-4 ... +140 °F) operating range ▪ ▪ IP65 (NEMA 4) metal housing ▪ Fully interchangeable Vaisala INTERCAP® Sensor ▪ Variety of analog signal outputs available Full 0 ... 100 %RH measurement range Excellent stability and high reliability Easy Maintenance Typical Applications The HMD42/53 humidity transmitters use Vaisala INTERCAP® Sensor - the interchangeable capacitive humidity sensor. The transmitters require no recalibration if the sensor is changed. This means great savings in overall maintenance costs. ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Reliable Performance in Harsh Environments The duct mount HMD42/53 transmitters can be installed in various measurement environments due to the robust IP65 (NEMA4) rated metal enclosure, which protects the sensor from dust and splashes of water. The wide measurement temperature range from -20 °C to +60 °C (-4 ... +140 °F) covers most HVAC applications. Office buildings Retail spaces Governmental buildings Educational facilities Sport and event complexes Hotels and conference centers Airports Metro stations Technical Data Relative Humidity General Measurement range Typical accuracy Temperature range 0 ... 90 %RH 90 ... 100 %RH Temperature range 0 ... 100 %RH 0 ... +40 °C (+32 ... +104 °F) ±3 %RH ±5 %RH -20 ... 0 °C, +40 ... +60 °C (-4 ... +32 °F, +104 ... +140 °F) 0 ... 90 %RH ±5 %RH 90 ... 100 %RH ±7 %RH Humidity sensor Vaisala INTERCAP® Stability ±2 %RH / 2 years Response time at 20 °C (+68 °F), 90 % response 15 s Temperature Measurement range Output scale Accuracy 0 ... +40 °C (+32 ... +104 °F) -20 ... 0 °C, +40 ... +60 °C (-4 ... +32 °F, +104 ... +140 °F) Sensor -20 ... +60 °C (-4 ... +140 °F) -40 ... +60 °C (-40 ... +140 °F) ±0.4 °C (±0.72 °F) ±0.6 °C (±1.1 °F) Pt1000 IEC 751 Class B General - HMD42 Supply voltage 10 ... 35 VDC (RL = 0 ohm) 20 ... 35 VDC (RL = 500 ohm) 4 ... 20mA Output signal General - HMD53 Operating temperature range electronics -5 ... +55 °C (+23 ... +131 °F) probe -20 ... +60 °C (-4 ... +140 °F) Storage temperature range -40 ... +60 °C (-40 ... +140 °F) Maximum flow speed 50 m/s Housing material probe stainless steel electronics cast aluminium Housing classification IP65 (NEMA 4) Connections screw terminal 0.5 ... 1.5 mm2 Cable thread-through bushing for 7 ... 10 mm (PG9) included (18941HM) Complies with EMC standard EN61326 and EN55022 Accessories Armoured cable gland Current module (for HMD53) 10528HM 18945HM Spare Parts Vaisala INTERCAP sensor, 1 piece Vaisala INTERCAP sensor, 10 pcs Membrane filter Sintered filter 15778HM INTERCAPSET-10PCS DRW010525 HM46670SP Dimensions Dimensions in mm 60 250 Supply voltage range depends on the selected output signal DC AC 0 … 1V 10 … 35V 9 … 24V 0 … 5V 14 … 35V 12 … 24V 0 … 10V 19 … 35V 16 … 24V Ø 12 WITH OPTIONAL CURRENT MODULE 82 100 100 0 ... 20 mA (RL= 0 ohm) 10 … 35V 11 … 24V **0 … 20 mA (RL=500 ohm) 20 … 35V 17 … 24V Power consumption @ 24VAC 12mA typical **Optional temperature scales are available on request. 82 For more information, visit www.vaisala.com or contact us at [email protected] Ref. B211140EN-A ©Vaisala 2011 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. Dew Point www.vaisala.com the user to monitor measurement trends and one-year history. The optional data logger with realtime clock makes it possible to generate more than four years of measured history and zoom in on any desired time or time frame. The display alarm allows tracking of any measured parameter, with a freely configurable low and high limit. Versatile outputs and (wireless) data collection The display shows measurement trends, real time data and history. The DMT340 can be connected to a network with an optional (W)LAN interface, which enables a (wireless) Ethernet connection. For serial interface also the USB connection, RS232 and RS485 can be used. Additionally an alarm relay option is available. The transmitter can have up to three analog outputs. Galvanic isolation of supply power and analog outputs are also offered. The recorded measurement data can be viewed on the display or transferred to a PC with Microsoft Windows® software. Easy installation The DMT340 has a variety of features to choose from. Units are delivered installation-ready. The Vaisala DRYCAP® HandHeld Dewpoint Meter DM70 is ideal for field checking DMT340 transmitters.tt Probe specifications Dimensions DMT342 with Small Size Flanged Probe Dimensions in mm (inches) 92.5 (3.64) Flange intersection ø12 (0.47) DMT340 Series Dewpoint and Temperature Transmitters for very dry conditions 41(1.61) ▪ ▪ ▪ 66 Withstands condensation Unique auto-calibration feature Optional alarm relays, local display and mains power supply module Compatible with Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 NIST traceable (certificate included) 3 analog outputs and a serial interface, WLAN/LAN Stability in low dew points The Vaisala DRYCAP® Sensor is immune to particulate contamination, water condensation, oil vapor and most chemicals. Since the sensor withstands condensation, its performance is unmatched for low dew point applications that experience water spikes in the process. The sensor recovers rapidly from contact with free water. Patented auto-calibration The stability of the DMT340 is due to the unique auto-calibration function, patented by Vaisala. Graphical measurement trend and history display The DMT340 can be ordered with a large numerical and graphical display with a multilingual menu. It allows Probe diameter The DMT342 probe is installed using a flange or sampling cell.The small probe is ideal for integrating into larger equipment. 16 9(0.35) ø36 (1.42) 71.5 (2.81) 12 mm/0.5 inch 58.7 (2.31) Installation Flange 36 mm/1.4 inch Sampling cell 45° 45° 1/8"-27 NPT ø24 .5 HMP302SC M 6 71 (2.80) Probe specifications Dimensions DMT344 with Probe for High Pressures Dimensions in mm (inches) Pressure range 0 ... 50 bar/0 ... 725 psia Mechanical durability Probe diameter 7 (0.28) 81 (3.19) Sampling cell HMP302SC ø32 (1.26) The DMT344 features a threaded connection for extended pressures with different fitting body options. It is ideal for permanent installations into pressurized or vacuum processes. M6 (0 .6 3) up to 250 bar/ 3625 psia up to 100 bar/ 1450 psia 12 mm/0.5 inch Ø 12 (0.47) ▪ Vaisala DRYCAP® Sensor provides accurate, reliable measurement with excellent long-term stability and fast response Mechanical durability M22x1.5 or NPT 1/2" ▪ ▪ ▪ Measures dew points from -60 °C to +80 °C (-76 ... +176 °F) with the accuracy of ±2 °C (±3.6 °F) The auto-calibration makes the transmitter perform a calibration and adjustment by itself while the measured process is running. If the measurement accuracy is not confirmed, corrections are made automatically. The procedure is so quick and corrections are so minor that it will go unnoticed. This ensures low maintenance and high performance. To continue performance at the highest level, the transmitter can be sent to Vaisala for a NIST traceable calibration. Calibration intervals depend on the application; in normal conditions, a NIST traceable calibration in every two years is recommended. ø12.5 (0.49) ▪ The Vaisala DRYCAP® Dewpoint and Temperature Transmitter Series DMT340 is designed for industrial low humidity applications. Typical applications include compressed air drying and metal treatment. The device is very reliable, easy to use and economical to maintain. 0 ... 50 bar/0 ... 725 psia 1/8"-27 NPT Features/Benefits 45° Pressure range 41 (1.61) 120 (4.72) 170 (6.69) Installation Fitting Body M22 x 1.5 Fitting Body NPT 1/2" 67 Technical data Probe specifications Dimensions Measured parameters DMT347 with Small Sized Probe Dimensions in mm (inches) DEW POINT up to 100 bar/ 145 psia 12 mm/0.5 inch Installation The DMT347 probe is ideal for tight spaces with thread connection.The small probe is installed using the Swagelok® connectors. Fitting Body R 3/8" ISO Fitting Body G 1/2" ISO Fitting Body NPT 1/2" (EXMM Probe specifications Dimensions DMT348 with Probe for Pipeline Installations Dimensions in mm (inches) Pressure range Adjustable length 20 ... 50 bar/290 ... 725 psia Vaisala DRYCAP®180M -60 ... +80 °C (-76 ... +176 °F) Td -60 ... +45 °C (-76 ... +113 °F) Td ±2 °C/±3.6 °F see the accuracy graph below additional inaccuracy +1 °C Td 215.5 (8.48) / 448 (17.6) 0 ... 40 bar/0 ... 580 psia 41 ... 149/371 mm/ 1.61 ... 5.87/14.6 inch Fitting Body NPT 1/2" Ball Valve Set BALLVALVE-1 Sampling Cell DMT242SC or DMT242SC2 41 (1.61) R1/2” ISO7/1 R1/2" ISO Ø 13.5 (0.53) Fitting Body 191 (7.52) / 410 (16.1) 41 (1.61) - 149 (5.87) / 41 (1.61) - 379 (14.9) Ø 12 (0.47) Installation The DMT348 is ideal for installations in pressurized processes where the probe needs to be removed while the process is running.The probe depth is adjustable. ) 3 / v . 0 4 v OR' v)3/ Mechanical durability Probe diameter 0 ... 10 bar/0 ... 145 psia Pressure range Sensor Measurement range For continuous use Accuracy up to 20 bar/290 psia Inputs and outputs 35 (1.37) Dew point accuracy vs. measurement conditions Response time 63% [90%] at +20°C gas temperature Flow rate 1 l/min and 1 bar pressure -60 ... -20 °C Td (-76 ... -4 °F Td) 5s [10s] -20 ... -60 °C Td (-4 ... -76 °F Td) 45s [10min] TEMPERATURE Measurement range Accuracy Temperature sensor 0 ... +80 °C (+32 ... +176 °F) ±0.2 °C at room temperature Pt 100 IEC 751 1/3 class B RELATIVE HUMIDITY Optional filter for low pressures (for all models) Measurement range Accuracy (RH <10 %RH, at + 20 °C) 0 ... 70 %RH ±0.004 %RH + 20 % of reading PPM Measurement range (typical) 10 ... 2500 ppm Accuracy (at + 20 °C, 1 bar) 1 ppm + 20 % of reading Other measurement parameters available (depends on model) mixing ratio, absolute humidity, pressure dew point calculated to 1 bar, temperature difference (T-Td), water vapor pressure Operating environment Operating temperature for probes -40 ... +80 °C (-40 ... +176 °F) Mechanical durability Up to +180 °C (+356 °F) for transmitter body -40 ... +60 °C (-40 ... +140 °F) with display 0 ... +60 °C (+32 ... +140 °F) Storage temperature range -55 ... +80 °C (-67 ... +176 °F) Pressure range for probes See probe specifications Sample flow rate No effect Measured gases non corrosive Complies with EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements; Industrial environment. 68 Operating voltage 10 ... 35 VDC, 24 VAC with optional power supply module 100 ... 240 VAC 50/60 Hz Power consumption @ 20 °C (Uin 24VDC) RS-232 max 25 mA max 25 mA Uout 2 x 0...1V / 0...5V / 0...10V Iout 2 x 0...20 mA max 60 mA display and backlight + 20 mA during sensor purge + 110 mA max Analog outputs (2 standard, 3rd optional) current output 0 ... 20 mA, 4 ... 20 mA voltage output 0 ... 1 V, 0 ... 5 V, 0 ... 10 V Accuracy of analog outputs at 20 °C 0.05 % full scale Temperature dependence of the analog outputs ± 0.005 %/°C full scale External loads current ouputs RL < 500 ohm 0 ... 1V output RL > 2 kohm 0 ... 5V and 0 ... 10V outputs RL > 10 kohm Max wire size 0.5 mm2 (AWG 20) stranded wires recommended Digital outputs RS-232, RS-485 (optional) Service connection RS-232, USB Relay outputs 0.5 A, 250 VAC, SPDT (optional) Ethernet interface (optional) Supported standards 10/100Base-T Connector RJ45 Protocols Telnet WLAN interface (optional) Supported standards 802.11b Antenna connector type RP-SMA Protocols Telnet Security WEP 64/128,WPA Authentication / Encryption Open / no encryption Open / WEP WPA Pre shared key / TKIP WPA Pre shared key / CCMP (a.k.a. WPA2) Optional data logger with real-time clock Logged parameters max. three with trend/min/max values Logging interval 10 sec (fixed) Max. logging period 4 years 5 months Logged points 13,7 million points per parameter Battery lifetime min. 5 years Display LCD with backlight, graphic trend display of any parameter Display menu languages English, Chinese, Spanish, German, French, Japanese, Russian, Swedish, Finnish 69 Dimensions Cable bushing M20x1.5 for cable diameter 8 ... 11mm/0.31 ... 0.43” Conduit fitting 1/2”NPT User cable connector (optional) M12 series 8 pin (male) option 1 with plug (female) with 5 m / 16.4 ft black cable option 2 with plug (female) with screw terminals USB-RJ45 Serial Connection Cable order no. 219685 Probe cable diameter 5.5 mm Probe cable lengths 2 m, 5 m or 10 m Housing material G-AlSi 10 Mg (DIN 1725) Housing classification IP 65 (NEMA 4X) Dimensions in mm (inches) 77 (3.03) 71 (2.80) Mechanics 183 (7.20) 7 (0.28) Ø 96 (3.78) 116 (4.57) 169 (6.65) Ensure dry compressed air with dewpoint measurement DRYCAP® is a registered trademark of Vaisala. Vaisala innovated DRYCAP® dewpoint instruments have been developed for the most demanding conditions. ▪ ▪ ▪ ▪ Fastest wet-to-dry response time on the market - just minutes High resistance to contamination - immune to compressor oil Complete recovery from saturated conditions Long 2-year calibration interval Want to know more? Our experts welcome your most difficult questions. TYPE APPROVED PRODUCT CERTIFICATE NO.: A-11440 For more information, visit www.vaisala.com or contact us at [email protected] 70 Ref. B210952EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com/compressedair [email protected] 71 www.vaisala.com DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications DMT346, Reliable in very hot processes trends and up to one-year measurement history. When process temperatures range between 140 °C to 350 °C, the DMT346 provides the best measurement performance. The optional data logger with real-time clock makes it possible to generate more than four years of the measured history and zoom in on any desired time or time frame. The DMT346 comes with a cooling set as a standard feature. The cooling effect may be regulated by adding the cooling fins, or removing them from the set for the best measurement performance. Versatile outputs and (wireless) data collection The cooling system operates without moving parts, additional power or cooling utilities, thereby eliminating the risk of sensor damage due to a mechanical cooling failure. The large and clear display allows the user to check data at a glance. Additionally, sensor warming minimizes the risk of condensing on the sensor. In low humidity the combination of auto-calibration and DRYCAP® ensures accurate measurement. Graphical display The Vaisala DRYCAP® Dewpoint Transmitters DMT345 and DMT346 are designed to measure and control humidity especially in dry environments with high temperatures. Features/Benefits ▪ The DMT345 measures humidity in temperatures up to 180 °C (356 °F) ▪ The DMT346 measures humidity in temperatures up to 350 °C (+662 °F) ▪ Dewpoint accuracy ±2 °C (±3.6 °F) ▪ Vaisala DRYCAP® Sensor provides accurate, reliable measurement with excellent long-term stability and fast response ▪ ▪ ▪ Both transmitters incorporate the Vaisala DRYCAP® sensor, which is accurate, reliable, and stable. The sensor withstands condensation and is immune to particulate contamination, oil vapor and most chemicals. The DRYCAP® sensor stands out for its swift response time and rapid recovery after getting wet. Withstands condensation Unique auto-calibration feature Optional local display with keypad, mains power supply module and alarm relays ▪ NIST traceable calibration (certificate included) ▪ Analog outputs, WLAN/LAN 72 The Vaisala DRYCAP® Dewpoint Transmitters DMT345 and DMT346 are designed for humidity measurement in industrial drying applications with particularly high temperatures. Measure humidity directly in hot processes The DMT345 and DMT346 are constructed for direct measurement in hot processes. Therefore, there is no need for sampling systems and trace heating. As a result, high accuracy and constancy are maintained. The accuracy and stability of the DMT345 and the DMT346 are due to the unique auto-calibration function, patented by Vaisala. This autocalibration makes the transmitter perform a calibration and adjustment by itself while the measured process is running. If the measurement accuracy is not confirmed, corrections are made automatically. The procedure is so quick and corrections are so minor that it will go unnoticed. This ensures low maintenance and high performance. In normal conditions, it is recommended to have a traceable calibration performed once a year. The DMT345 and DMT346 transmitters can be ordered with a large numerical and graphical display, which allows the user to clearly monitor operational data, measurement For serial interface also the USB connection, RS232 and RS485 can be used. Additionally an alarm relay option is available. The transmitter can have up to three analog outputs. Galvanic isolation of supply power and analog outputs are also offered. The recorded measurement data can be viewed on the display or transferred to a PC with Microsoft Windows® software. Units are delivered installation-ready and meet ROHS requirements. Technical data Measured variables DMT345 TEMPERATURE DMT345 DEWPOINT DMT345 Sensor Measurement range Accuracy Vaisala DRYCAP®180S -40 ... +100 °C (-40 ... +212 °F) Td ±2°C (±3.6 °F) Td See the accuracy graph below Measurement range with sensor warming Accuracy Temperature sensor DMT345, Accurate in hot and dry environments 0 ... +180 °C (+32 ... +356°F) upper range limited by humidity (at 80% RH warming is switched on and T reading not actual process Temperature) ±0.4 °C at 100 °C Pt 100 IEC 751 1/3 class B RELATIVE HUMIDITY DMT345 The DMT345 is designed for accurate humidity measurement in hot and dry conditions. This model provides unmatched dry end measurement accuracy in temperatures up to 140 °C, however the DMT345 can operate safely in temperatures up to 180 °C. The stainless steel probe is especially designed for high temperatures and has an optional installation flange that allows an adjustable installation depth and therefore a precise positioning. The transmitter can be connected to a network with an optional (W)LAN interface, which enables a (wireless) Ethernet connection. Measurement range with sensor warming Accuracy below 10 % RH above 10 % RH 0 ... 100 % RH 0 ... 80 % RH ±10 % of reading ±1,5% RH + 1,5 % of reading MIXING RATIO DMT345 Dewpoint accuracy vs. measurement conditions Measurement range (typical) Accuracy (typical) 0 ... 1000 g/kg (0 ... 7000 gr/lbs) ±12% of reading Response time 63 % [90 %] flow rate 1 l/min and 1 bar pressure from dry to wet 5s [10 s] from wet to dry including auto-calibration 45s [5 min] 73 Technical data Dimensions Dimensions in mm (inches) DMT345 probe and mounting flange DMT345 and DMT346 Transmitter housing 77 (3.03) 71 (2.80) DRILLING 183 (7.20) 169 (6.65) DMT346 Cooling set 304 (11.97) 164 (6.46) 112.5 (4.43) 120 (4.72) 40.6 (1.6) ø105 (4.13) ø118 (4.65) ø28 (1.1) 8 15 (0.59) (0.31) ø89 (3.5) ø20 (0.79) ø7 (0.28) 96 (3.78) 116 (4.57) 27.5 (1.08) sintered filter (fixed on top of the cooling set) 125 (4.92) cooling element mounting flange cooling fins DMT346 Probe Stainless steel grid cable 2,5 or 10 m 357 (14.1) 334.5 (13.17) ø 11 (0.43) 22.5 (0.89) ø13.5 (0.53) DRYCAP® is a registered trademark of Vaisala. For more information, visit www.vaisala.com or contact us at [email protected] 74 Ref. B210723EN-C ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 75 www.vaisala.com DMT242 Dewpoint Transmitter for OEM Applications Technical data Dewpoint temperature Operating environment Measurement range (typical) -60 ... +60 °C (-76 ... +140 °F) Analog output scalings Option A -80 ...+20 °C (-112 ... +68 °F) Td Option B -60 ... +60 °C (-76 ... +140 °F) Td Option X free scaling (when the dewpoint is below 0 °C (32 °F), the transmitter outputs frostpoint) Accuracy with DRYCAP® 180M ±2 °C (±3.6 °F) (see graph below) Temperature higher temperature peaks Relative humidity Pressure Sample flow rate 0 ... +60 °C (32 ... +140 °F) Short-term OK 0 ... 100 %RH 0 ... 20 bara (0 ... 290 psia) no effect Output Analog output Resolution for analog output Typical temperature dependence Serial line for service use 4 ...20 mA ±0.002 mA 0.0008 mA/ °C RS232 General Due to its wide measurement range and high long-term stability, the DMT242 is an ideal choice for low dewpoint industrial applications such as compressed air dryers, plastic dryers and other OEM applications. The Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 is ideal for confirming the performance of the DMT242 in the field. DEWPOINT ACCURACY VS. MEASUREMENT CONDITIONS ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ 76 Ideal choice for industrial dryer applications Incorporates advanced Vaisala DRYCAP® Sensor and enhanced auto-calibration software Long-term stability in low dewpoints Fast response time Two sensor options cover dewpoint measurement range from -60 … +60 °C (-76 … +140 °F) with an accuracy of ±2 °C (±3.6 °F) Withstands condensation NIST traceable (certificate included) Compatible with Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 Vaisala DRYCAP ® The Vaisala DRYCAP® Dewpoint Transmitter DMT242 provides reliable and stable measurements for industrial dryer applications. It is designed for extreme conditions. DMT242 incorporates the Vaisala DRYCAP® thin film polymer sensor and auto-calibration software. The standard sensor choice for dry gases and desiccant dryers is DRYCAP® 180M and for more humid applications such as refigeration dryers, a DRYCAP® 180S sensor. Both the sensors are immune to particulate contamination, water condensation, oil vapor and most chemicals. Because the sensor withstands condensation, its performance is unmatched for low dewpoint applications that experience process water spikes, such as pipeline condensation during a system failure or start-up. The auto-calibration software works on-line while the process is running. If the measurement accuracy is not confirmed, corrections are made automatically. The DMT242 adjusts the measurement, corrects dry-end drifts and continues to function. Calibration occurs quickly, and with corrections so minor, it will go unnoticed. Compact, rugged and intelligent Due to its compact size, DMT242 is quickly and easily installed in tight spaces. Users can perform a field-check by using the Vaisala DRYCAP® HandHeld Dewpoint Meter DM70. The transmitter can be sent to Vaisala Service for NIST traceable calibration. The recommended calibration interval is every two years. Response time 63 % [90 %] at +20 °C gas temperature Flow rate >1 l/min and 1 bar pressure -60 -> -20 °C Td (-76 -> -4 °F Td) 5 s [10 s] -20 -> -60 °C Td (-4 -> -76 °F Td) 45 s [10 min] ±2 °C (±3.6 °F) Accuracy with DRYCAP® 180S (see graph below) DRYCAP® 180M DRYCAP® 180S 18 - 35 VDC, 20 - 28 VAC max. 220 mA max. 500 Ω 2 m or 10 m 0.75 mm2 6.5 mm /PG7 product code DMT242RS Probe material (wetted parts) Dewpoint temperature (°C) Features/Benefits Sensor Optimal sensor for refrigeration dryers Operating voltage Power consumption at 24 VDC External load for analog output Optional connection cable with DMT242 connector Connector for supply voltage and signal output max. wire size max. cable diameter Service cable for serial interface RS232 70 60 50 40 30 20 10 0 -10 -20 -30 -40 -50 -60 -70 -80 Water vapor satura e tion lin y < ± 2°C Accurac Td it lower lim urement range Dewpoint meas 0 10 20 30 40 50 60 stainless steel (AISI 316L) Sensor protection stainless steel sintered filter (HM47280) Mechanical connection G½” ISO228-1 thread with bonded seal ring (U-seal) Eletronics housing material plastic (ABS/PC) Housing classification IP65 (NEMA4) Storage temperature range -40 ... +70 °C, (-40 ... +158 °F) Complies with the EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements; Industrial environment. Process temperature (°C) For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210765EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 77 Measured variables General DEW POINT TEMPERATURE Sensor Dew point temperature (°C) Measurement range -80 ... -10 °C (-112 ... +14 °F)Td Accuracy ±2 °C (3.6 °F) Td Non-calibrated range -100 ... +20 °C (-148 ... +68 °F)Td Analog output scalings option 1 -80 ... +20 °C (-112 ... +68 °F) Td option 2 -100 ... 0 °C (-148 ... +32 °F) Td option 3 user-specified output scaling when dew point is below 0 °C (32 °F) the transmitter outputs frost point Accuracy over temperature range 30 20 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -10 Typical accuracy +5 °C Td Not recommended for continuous measurement Accuracy +2 °C Td or better Accuracy not specified -30 -20 -10 0 10 20 30 40 50 60 70 Temperature of measured gas (°C) The small and powerful DMT152 measures dew point down to -80 °C. Features/Benefits DMT152 Applications ▪ ▪ ▪ Compact ▪ Measures dew point down to -80 °C (-112 °F ) The DMT152 is an ideal choice for industrial applications where it is necessary to control very low humidity. Most typical areas of use are air and plastics dryers, dry chambers, pure gases, and highvoltage circuit breakers. ▪ Reduced maintenance costs due to long calibration interval The Vaisala DRYCAP® Dewpoint Transmitter DMT152 is designed for measuring low dewpoint in OEM applications, even down to -80°C . The excellent long-term stability and reliability of its performance is based on the latest DRYCAP® polymer sensor technology. ▪ ▪ ▪ ▪ Fast response time Accurate Vaisala DRYCAP® technology with a polymer sensor Withstands condensation NIST traceable Applications: compressed air, plastics drying, dry chambers, pure gases, and high-voltage circuit breakers Low maintenance The DMT152 mechanics have been designed for harsh environments requiring protection against dust, dirt, and splashed water. The DRYCAP® technology has a low maintenance need due to its excellent long-term stability and durability against condensation. The DMT152 measures accurately and reliably also in the challenging combination of low humidity and hot air, which is typical in plastics drying. Response time 63 % [90 %] at a gas temperature of +20 °C (+68 °F) and pressure of 1 bar -10 ... -80 °CTd 0.5 min [7.5 min] -80 ... -10 °CTd 2 s [5 s] PPM VOLUME CONCENTRATION Measurement range (typical) Accuracy at +20 °C (+68 °F), 1013 mbar 0 ... 500 ppm Accessories ±(0.2 ppm + 20 % of reading) Operating environment Temperature Relative humidity Pressure Measured gases Sample flow rate -40 ... +70 °C (-40 ... +158 °F) 0 ... 100 %RH (up to + 20 °C/68 °F) 0 ... 50 bar (725 psia) non-corrosive gases no effect on measurement accuracy Connection cable for MI70 hand-held indicator USB cable for pc connection Sampling cells (available for ISO G½”) basic sampling cell with Swagelok 1/4” male connectors with a quick connector and leak screw two-pressure sampling cell NW40 flange Outputs Two analog outputs (scalable) 4 ... 20 mA, 0 ... 20 mA (3 wire) 0 ... 5 V, 0 ... 10 V Accuracy of analog outputs ± 0.01 V / ±0.01 mA Digital output RS485 (2-wire) Alarm-level indication by analog signal user selectable Purge information 5 V, 10 V, 20 mA or LED For more information, visit www.vaisala.com or contact us at [email protected] 78 Vaisala DRYCAP® 180U Thin-film capacitive polymer sensor Recommended calibration interval 2 years Operating voltage with RS485 output 11* ... 28 VDC voltage output 15* ... 28 VDC current output 21 ... 28 VDC *For extended temp. down to -40 °C (-40 °F) or pressure up to 50 bar (725 psia), the supply voltage is 21 ... 28 VDC. Supply current normal measurement 20 mA + load current during self-diagnostics max. 220 mA pulsed Supply voltage fluctuation max. 0.3 V External load for voltage output min. 10 kOhm current output max. 500 Ohm Housing material (wetted parts) AISI316L Stainless steel mesh filter AISI303, filter grade 18 μm ISO G½”, NPT ½", UNF 3/4”- 16” Mechanical connections Housing classification IP65 (NEMA 4) Storage temperature range -40 ... +80 °C (-40 ... +176 °F) Weight (ISO G½”) 190 g (6.70 oz) Complies with EMC standard EN61326-1, Electrical equipment for measurement control and laboratory use - EMC requirements; Industrial environment 2.99 76 4.74 120.5 219980 219690 DMT242SC DMT242SC2 DSC74 DSC74B 225220SP 1.3 3 Ø3 1.28 32.5 0.47 Ø 12 DMT152 Dewpoint Transmitter for Low Dew point Measurement in OEM Applications Technical data 1.16 Ø 29.5 www.vaisala.com 1.18 AW 30 G 1/2" ISO 228-1 Ref. B210750EN-C ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 79 www.vaisala.com DMT142 Miniature Dewpoint Transmitter for OEM Applications Technical data Measured variables DEW POINT TEMPERATURE Measurement range(typical) Standard version -40 ... +60 °C (-40 ... +140 °F) Td Extended version -60 ... +60 °C (-76 ... +140 °F) Td SF6 version -50 ... +60 °C (-58 ... +140 °F) Td Analog output scalings option 1 -80 ...+20 °C (-112 ... +68 °F) Td option 2 -60 ... +40 °C (-76 ... +104 °F) Td option 3 free scaling Accuracy ±3 °C (±5.4 F) Td (see graph below) (when the dew point is below 0 °C (32 °F), the transmitter outputs frostpoint) The Vaisala DRYCAP® Dewpoint Transmitter DMT142 is an ideal choice for small compressed air dryers, plastic dryers and other OEM applications. The Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 is ideal for confirming the performance of the DMT142 in the field. Features/Benefits Vaisala DRYCAP® Long calibration interval ▪ The Vaisala DRYCAP® Dewpoint Transmitter DMT142 is a miniature dew point measurement instrument. The transmitter can be installed directly into pressurized systems at 50 bar (725 psia) maximum pressure. The long-term high performance is achieved with Vaisala DRYCAP® technology. The calibration interval of the DMT142 is two years. Additionally, the Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 can be used to confirm the performance of the DMT142 without disconnecting the transmitter. For any adjustment needs, the transmitter can be sent to Vaisala Service. The sensor fully withstands getting wet, and therefore, the transmitter performs exceptionally well in applications that occasionally experience process water spikes, such as pipeline condensation during a system failure or start-up. The sensor is also immune to particulate contamination, oil vapor and most chemicals, and is insensitive to the flow rate. The auto-calibration software works on-line while the process is running. If the measurement accuracy is not confirmed, corrections are made automatically. ▪ ▪ ▪ ▪ ▪ ▪ ▪ 80 Miniature size dew point transmitter for e.g. small industrial dryer applications Vaisala DRYCAP® technology with auto-calibration Calibration interval of two years Dew point measurement range -60 ... +60 °C (-76 ... +140 °F) with an accuracy ±3 °C (±5.4°F) Withstands condensation Fast response time Compatible with Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 NIST traceable (certificate included) Easy installation The DMT142 has a variety of features to choose from, including different output and installation options. Due to its small size and light weight, the DMT142 is quickly and easily installed in tight spaces or in smallsize pipelines. DEW POINT ACCURACY VS. MEASUREMENT CONDITIONS Dew point accuracy range for the extended version. Standard version with dotted line. Response time 63% [90%] at +20 °C gas temperature and 1 bar pressure -60 -> -20 °C Td (-76 -> -4 °F Td) 5 s [10 s] 45 s [10 min] -20 -> -60 °C Td (-4 -> -76 °F Td) PPM VOLUME CONCENTRATION Measurement range 70 ... 200 000 ppm Accuracy at +20 °C (+68 °F), 1013 mbar 7.3 ppm + 9.2% of reading Operating environment Temperature *) -40 ... +60 °C (-40 ... +140 °F) Relative humidity 0 ... 100 %RH Pressure *) 0 ... 50 bara (725 psia) Sample flow rate no effect for measurement accuracy *) For extended temperature down to -40 °C (-40 °F) or pressure up to 50 bara (725 psia) the supply voltage must be 24 ... 28 VDC. Outputs Analog output (scalable) 4 ... 20 mA (3-wire), 0 ... 1 V/5 V Resolution for current output 0.002 mA Resolution for voltage output 0.3 mV Typical temperature dependence 0.005% of span / °C Connector 4-pin M8 (IEC 60947-5-2) connection cable with snap-on or thread locking available RS232 serial line for service use with DMT142RS cable General Sensor Measured gases Vaisala DRYCAP® 180D non-corrosive gases (SF6 gas with special model) Recommended calibration interval to confirm the specified accuracy 2 years Operating voltage with voltage output 12 ... 28 VDC Operating voltage with current output 18 ... 28 VDC Supply current normal measurement 10 mA + load current during self-diagnostics max. 220 mA pulsed Load for current output max. 500 ohm Load for voltage output min. 10 kohm Housing material stainless steel body (AISI316L) plastic cap(ABS/PC) Sensor protection stainless steel sintered filter Mechanical connection G1/2” ISO 228-1 thread with bonded seal ring (U-seal) Housing classification IP64 (NEMA 3S) Storage temperature range -40 ... +80 °C (-40 ... +176 °F) Weight 118 g (4.16 oz) Complies with EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements; Industrial environment. Accessories Output cable M8, snap-on connector, 2 meters 211598 Output cable M8, thread connector, 3 meters HMP50Z300, several lengths available Connection cable for DM70 211917ZZ Service cable for serial line DMT142RS Sampling cells basic sampling cell DMT242SC with Swagelok 1/4" male connectors DMT242SC2 with quick connector and leak screw DSC74 two-pressure sampling cell DSC74B cooling/venting coil DMCOIL See DM70 / Portable Sampling Systems and Sampling Cells for further information about sampling cells available Ref. B210375EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 81 www.vaisala.com DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications Technical data TEMPERATURE The Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dew point applications, such as compressed air, metal treatment and plastics drying. response from ambient to dry conditions exceptionally fast. The DM70 is fitted with the Vaisala DRYCAP® Sensor. The sensor provides reliable, stable and high-performance dew point measurement. Autocalibration detects on-line possible measurement inaccuracies and automatically corrects dry-end drift in the calibration curve. Measurement range Accuracy at +20 °C (+68 °F) Typical temperature dependence of electronics Temperature sensor ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Designed for industrial spot-checking and field calibration Three models: accurate measurement ranges from -60 to +60 °C (-76 ... +140 °F) Vaisala DRYCAP® Sensor with patented autocalibration function Low maintenance need due to superior long-term stability Sensor withstands condensation Fast response, enhanced by Sensor Purge option Easy-to-use user interface Data can be logged and transferred to a PC via MI70 Link software Compact, small and light NIST traceable (certificate included) The Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 measures dew point temperature accurately over a wide measurement range. The probe may be inserted directly into pressurized processes, and it responds rapidly from ambient to process conditions. The sensor withstands condensation and fully recovers from getting wet. Three probe models, all with auto-calibration, are available. The A and B models are both general purpose probes. The C model is specifically developed for SF6 gas. The B and C probe models have an additional Sensor Purge feature that heats and dries the sensor, making the 82 The DM70 displays one to three parameters at a time, either numerically or graphically. Several humidity units can be selected. In addition, the DM70 includes conversion from gas pressure dew point to ambient pressure dew point. An analog output is also available. The DM70 meter is suitable for direct process dew point measurement in a wide temperature and pressure range. For more demanding applications, the DM70 can be used with the Vaisala sampling cell adapters, or with the Vaisala DRYCAP® Sampling System DSS70A. Dew point converted to atmospheric pressure, ppm volume and ppm weight concentration, absolute humidity, mixing ratio, relative humidity DEW POINT Measurement range (typical) Accuracy (B and C probe) -60...+20 °C Dotted line: For DMP74C the ±2 °C accuracy range is limited to -50 °C Td when used in SF6 gas. Response time flow rate 0.2 m/s, 1 bar pressure, +20 °C (+68 °F) 63% [90%] 0 -> -60 °C Td (32 -> -76 °F Td) 50 s [340 s] -60 -> 0 °C Td (-76 -> 32 °F Td) 10 s [20 s] Dew point sensor Vaisala DRYCAP® 180M TEMPERATURE DEW POINT OTHER VARIABLES AVAILABLE -50 ... +60 °C (-58 ... +140 °F) ±2 °C (±3.6 °F) (see graph) -70 ... +30 °C (-94 ... +86 °F) ±2 °C (±3.6 °F) (see graph) Dew point accuracy vs. measurement conditions Measured variables, DMP74A probe Measurement range (typical) Accuracy (A probe) -40...+60 °C -10 ... +60 °C (+14 ... +140 °F) ±0.2 °C (±0.36 °F) ±0.005 °C/°C (±0.005 °F/°F) Pt100 IEC751 1/3 class B Dew point converted to atmospheric pressure, ppm volume and ppm weight concentration All probe models Dew point accuracy vs. measurement conditions Response time flow rate 0.2 m/s, 1 bar pressure, +20 °C (+68 °F) 63% [90%] 0 -> -40 °C Td (32 -> -40 °F Td) 20 s [120 s] -40 -> 0 °C Td (-40 -> 32 °F Td) 10 s [20 s] Dew point sensor Vaisala DRYCAP® 180S Sample flow rate no effect for measurement accuracy Measured gases non-corrosive gases Probe material (wetted parts) Stainless steel (AISI 316L) Sensor protection Sintered filter (AISI 316L) partno: HM47280 Mechanical connection G1/2” ISO228-1 thread with bonded seal ring (U-seal) Housing classification IP65 (NEMA 4) Weight 350 g MI70 indicator, general Measured variables, DMP74B and DMP74C (for SF6 gas) probes Measurement range Accuracy at +20 °C (+68 °F) Typical temperature dependence of electronics Temperature sensor Technical data ±0.005 °C/°C (±0.005 °F/°F) Pt100 IEC751 1/3 class B OTHER VARIABLES AVAILABLE The DM70 has a versatile and easy-to-use, menu-based user interface, a clear graphical LCD display, and datalogging capability. It can also be used as a tool for reading the output of fixed Vaisala dew point transmitters, like the DMT242, DMT142, DMT152 and DMT340. Features/Benefits -10 ... +60 °C (+14 ... +140 °F) ±0.2 °C (±0.36 °F) Operating temperature Operating pressure DMP74A, DMP74B DMP74C -10 ... +60 °C (+14 ... +140 °F) 0 ... 20 bara (0 ... 290 psia) 0 ... 10 bara (0 ... 150 psia) Menu languages English, Chinese, Spanish, Russian, French, Japanese, German, Swedish, Finnish, Display LCD with backlight Graphic trend display of any parameter Character height up to 16 mm Max. no of probes 2 Power supply Rechargeable NiMH battery pack with AC-adapter or 4xAA size alkalines, type IEC LR6 Analog output 0...1 VDC Output resolution 0.6 mV PC interface MI70 Link software with USB or serial port cable Datalogging capacity 2700 points Alarm Audible alarm function Operating temperature range -10...+40 °C (+14…+104 °F) Storage temperature range -40 ... +70 °C (-40 ... +158 °F) Operating humidity range 0 ... 100 % RH, non-condensing Housing classification IP54 Housing materials ABS/PC blend Weight 400 g Battery operation time with DMP74 probe continuous use 48 h typical at +20 °C (+68 °F) data logging use up to a month, depending on logging interval Electromagnetic compatibility EN 61326-1, Generic Environment Accessories Connection cables for fixed Vaisala dew point transmitters for DMT242 transmitter 27160ZZ for DMT340 series 211339 for DMT152 transmitter 219980 for DMT142 transmitter 211917ZZ MI70 Link software with USB cable 219687 MI70 Link software with serial port cable MI70LINK Analog output cable 27168ZZ 10 m (32.81 ft) extension cable for probe 213107SP Ref. B010162EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 83 www.vaisala.com DSS70A Portable Sampling System and Sampling Cells for DM70 Technical data DMCOIL DMT242SC pressure limit DMT242SC2 DSS70A Sampling System and DSC74B/C Sampling Cells Filter Sample Gas Inlet Sampling Cell for Td Probe Needle Valve Flow meter Sample Pump Sample Gas Outlet pressure limit Material for all sampling cells DSS70A The DSS70A sampling system includes a filter to clean the dirty sample gas and a needle valve to control the sample flow rate with the flow meter. A sample pump is used to generate a sample flow from processes at ambient pressure. Measurement in gas pressure Sampling Cell for Td Probe Valve Removable flow limiter Sample gas outlet Sample gas inlet DSC74B DSS70A portable sampling system The DSS70A is designed to provide dewpoint sampling flexibility: for the DM70 hand-held dew point meter. For processes at atmospheric pressure, a battery powered pump is used to extract a gas sample. For pressurized processes up to 20 bar, the sample is measured at process pressure and then reduced to atmospheric pressure for venting or re-direction, bypassing the pump. In all cases, the sample gas passes through a filter to remove particulate contamination before measurement. Flow through the system is controlled and monitored with a needle valve and flow meter. The DSS70A is easily connected to an appropriate sample point with tubing (typically 1/4” or 6 mm). The measured dewpoint must be below ambient temperature to avoid condensation in the system. Gas 84 temperatures higher than +40 °C (+104 °F) should be cooled with a short PTFE (included in the DSS70A system) or stainless steel tube prior to entering the DSS70A. Sampling cells for pressurized processes The DM70 can easily be connected to pressurized processes. In addition to direct pipeline installation, a variety of sampling cell options are available for gas sampling. The DSC74 sampling cell is the recommended choice. It has a variety of connection adapters that allow several different ways of installation. The quick connector with a leak screw allows a very fast connection for compressed air lines. Additionally, two thread adapters are available for the inlet port. The DSC74B is a two-pressure sampling cell, which enables measurements in both process and DSS70A sampling system Operating conditions Operating gases Dewpoint range Inlet/outlet connection Operating temperature ambient temperature process gas temperature with PTFE tube at +20 °C (+68 °F) with stainless steel tube Sample gas outlet The DSS70A provides a compact solution for field checking dew point where direct measurement is difficult.Typical applications for the sampling system are metal treatment and plastics drying processes. Measurement in atmospheric pressure ambient pressure. This sampling cell is especially suitable for dewpoint measurements in SF6 gas with the DMP74C probe. The DMT242SC is a basic sampling cell. The DMT242SC2 is a sampling cell supplied with welded Swagelok connectors for sampling in a 1/4” pipeline. Sample gas inlet Removable flow limiter Valve Sampling Cell for Td Probe DSC74B Diffusion coil (included in the DSS70A) maximum gas temperature at inlet Operating pressure with pump pump disconnected air, N2 and other non-toxic, inert gases -70 °C ... Tamb (-76 °F ... Tamb) 1/4" Swagelok 0 ... +40 °C (32 ... +104 °F) max. +200 °C (+392 °F) specification according to stainless steel tube specification +40 °C (+104 °F) 0.6 ... 1.2 bara (8.7 ... 17.4 psia) 0 ... 20 bara (0 ... 290 psia) DSC74C The DSC74B sampling cell enables the measurement of the sampled gas either in gas pressure up to 10 bar or in atmospheric pressure depending on the gas inlet and outlet. The DSC74C is like the DSC74B but with an additional coil to avoid back diffusion, the effect of surrounding moisture, in dewpoint measurements in atmospheric pressure. Sampling cells technical data DSC74 pressure limit DSC74B pressure limit DSC74C The sampling cells (from the left) DMT242SC2, DMT242SC and DSC74 can be used to connect the DM70 to sample gas flow.The DSC74B (right) is a twopressure sampling cell that can be used for measurements in either pressurized or ambient pressure.The cooling/venting coil is included in the DSC74C sample cell, but is an option for all sampling cells. cooling/venting coil sampling cell 10 MPa (100 barg, 1450 psig) sampling cell with Swagelok connectors 4 MPa (40 barg, 580 psig) stainless steel AISI316 sampling cell for pressurized gases 1 MPa (10 barg, 145 psig) two pressure sampling cell 1 MPa (10 barg, 145 psig) DSC74B with DMCOIL cooling/ venting coil General Battery operation time for pump 8 h continuous use battery can be recharged using DM70 charger Filter 7 mm inline filter cartridge 1/4" Swagelok SS-4F-7 (spare part order no. 210801) Materials wetted parts Stainless steel carrying case ABS plastic Case size (W x D x H) 430 x 330 x 100 mm Weight 5.5 kg (12 lbs) Electromagnetic compatibility EN61326-1, Generic Environment. Ref. B210833EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 85 Moisture in Oil www.vaisala.com MMT330 Moisture and Temperature Transmitter Series for Oil Water content as ppm conversion zoom in on any desired time or time frame. In addition to water activity, the MMT330 can output ppm, the average mass concentration of water in oil. Vaisala has this conversion readily availabe for mineral transformer oil. The display alarm allows tracking of any measured parameter, with a freely configurable low and high limit. For other oils, the oil specific conversion coefficients can be programmed to the transmitter if the water solubility of the oil is known. The display shows measurement trends, real time data and history. Graphical measurement trend and historical display The MMT330 can be ordered with a large numerical and graphical display with a multilingual menu. It allows the user to monitor operational data, measurement trends and up to 1-year measurement history. The optional data logger with real-time clock makes it possible to generate over four years of measured history, and Data collection and (wireless) transfer to PC The recorded measurement data can be viewed on the display or transferred to a PC with Microsoft Windows® software. The transmitter can also be connected to a network with an optional (W)LAN interface, which enables a (wireless) Ethernet connection. Versatile outputs and easy installation The MMT330 provides up to three analog outputs. Galvanic isolation of supply power and analog outputs is also available. For serial interface the USB connection, RS232 and RS485 The Vaisala HUMICAP® Hand-Held Moisture for Oil Meter MM70 is designed for field checking MMT330 transmitters. can be used. In addition, alarm relay option is available. The MMT330 has several options for transmitter mounting. Transmitters are delivered pre-configured with all settings installation ready. The MMT330 transmitter family offers a range of solutions for demanding moisture in oil measurements. Features/Benefits ▪ Continuous on-line measurement of moisture in oil ▪ Ball valve installation – no need to shut down the process ▪ Incorporates Vaisala HUMICAP® Sensor – more than 30 years of field performance ▪ Ten years of experience in measuring moisture in oil ▪ ▪ Excellent long-term stability Easy to calibrate and maintain in the field - Compatible with Vaisala HUMICAP® Hand-Held Moisture for Oil Meter MM70 ▪ NIST traceable calibration (certificate included) ▪ Analog outputs, WLAN/LAN 86 The Vaisala HUMICAP® Moisture and Temperature Transmitter Series for Oil MMT330 enables fast and reliable detection of moisture in oil. The MMT330 can be used in on-line moisture monitoring and as a control device, allowing separators and oil driers to be started only when needed. Proper monitoring saves both oil and the environment. With the MMT330 it is easy and economical to monitor the changes of moisture in oil. Reliable Vaisala HUMICAP® technology The MMT330 incorporates the latest generation of the Vaisala HUMICAP® Sensor, which is the result of ten years of field experience. It was developed for demanding moisture measurement in liquid hydrocarbons. The sensor's excellent chemical tolerance provides accurate and reliable measurement over a wide measurement range. For diverse applications and demanding conditions Because of the variety of probes, the transmitter can be used in lubrication systems, hydraulic systems, and transformers. Indicates the margin to water saturation The MMT330 measures moisture in oil in terms of the water activity (aw) and temperature (T). Water activity indicates directly whether there is a risk of free water formation. The measurement is also independent of oil type and age. 87 Technical data Installation options Dimensions Measured values MMT332 For High Pressure Installations Dimensions in mm (inches) WATER ACTIVITY Flange 36 mm / 1.4 inch Inputs and outputs Mechanics TEMPERATURE MMT337 with Small Sized Probe Dimensions in mm (inches) )3/OR .04 Dimensions 0 ... 10 bar / 0 ... 145 psia Probe diameter 12 mm / 0.5 inch Installation Fitting Body R 3/8" ISO Fitting Body 1/2" ISO Fitting Body NPT 1/2" Measurement range MMT332 MMT337 MMT338 Accuracy at +20 °C (+68 °F) Hex 22m (0.87) -40 ... +180 °C (-40 ... +356 °F) -40 ... +180 °C (-40 ... +356 °F) -40 ... +180 °C (-40 ... +356 °F) ± 0.2 °C (0.36 °F) Operating environment Operating temperature for probes for transmitter body with display Pressure range for probes same as measurement ranges -40 ... +60 °C (-40 ... +140 °F) 0 ... +60 °C (+32 ... +140 °F) See probe specifications Temperature Measurement range -40 ... +180 °C (-40 ... 356 °F) Dimensions MMT338 with Probe for Pipeline Installations Dimensions in mm (inches) up to 120 °C (248 °F) and 40 bar 0 ... 40 bar / 0 ... 580 psia Installation options Pressure range with ball valve R1/2" ISO7/1 Adjustable length 35 ... 157/379 mm / 1.37 ... 6.2 /14.9 inch Installation Fitting Body Fitting Body Ball Valve Set Sampling Cell R1/2" ISO NPT 1/2" BALLVALVE-1 DMT242SC2 Temperature Measurement range 88 Complies with EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements; Industrial environment. Performance -40 ... +180 °C (-40 ... 356 °F) Installation options Pressure range The MMT338 is ideal for installations in pressurized processes where the probe needs to be removed while the process is running.The probe depth is adjustable. Measurement range aw 0 ... 1 Accuracy (including nonlinearity, hysteresis and repeatability) 0 ... 0.9 ±0.02 0.9 ... 1.0 ±0.03 Response time (90 %) at +20 °C in still oil (with stainless steel filter) 10 min. Sensor HUMICAP® Temperature Measurement range The MMT337 probe, with optional Swagelok connector, is ideal for tight spaces with a thread connection.The small probe is designed for integrating into confined spaces with small diameter lines. Installation The MMT332 probe is installed using a flange. It is for high pressure applications. 12 mm / 0.5 inch - Probe diameter ² 0 ... 250 bar / 0 ... 3625 psia Pressure range Max wire size 0.5 mm2 (AWG 20) stranded wires recommended Digital outputs RS-232, RS-485 (optional) Service connection RS-232, USB Relay outputs 0.5 A, 250 VAC, SPDT, Potential Free (optional) Ethernet interface (optional) Supported standards 10/100Base-T Connector RJ45 Protocols Telnet WLAN interface (optional) Supported standards 802.11b Antenna connector type RP-SMA Protocols Telnet Security WEP 64/128,WPA Authentication / Encryption Open / no encryption Open / WEP WPA Pre shared key / TKIP WPA Pre shared key / CCMP (a.k.a. WPA2) Optional data logger with real-time clock Logged parameters max. three with trend/min/max values Logging interval 10 sec (fixed) Max. logging period 4 years 5 months Logged points 13,7 million points per parameter Battery lifetime min. 5 years Display LCD with backlight, graphic trend display of any parameter Display menu languages English, Chinese, Spanish, German, French, Japanese, Russian, Swedish, Finnish -40 ... +180 °C (-40 ... 356 °F) Operating voltage with optional power supply module Power consumption @ 20 °C (Uin 24VDC) RS-232 Uout 2 x 0...1V / 0...5V / 0...10V Iout 2 x 0...20 mA display and backlight Analog outputs (2 standard, 3rd optional) current output voltage output Accuracy of analog outputs at 20 °C Temperature dependence of the analog outputs External loads current ouputs 0 ... 1V output 0 ... 5V and 0 ... 10V outputs 10 ... 35 VDC, 24 VAC 100 ... 240 VAC 50/60 Hz max 25 mA max 25 mA max 60 mA + 20 mA 0 ... 20 mA, 4 ... 20 mA 0 ... 1 V, 0 ... 5 V, 0 ... 10 V ± 0.05 % full scale Cable bushing M20x1.5 for cable diameter 8 ... 11mm/0.31 ... 0.43” Conduit fitting 1/2”NPT Interface cable connector (optional) M12 series 8 pin (male) option 1 with plug (female) with 5 m / 16.4 ft black cable option 2 with plug (female) with screw terminals USB-RJ45 Serial Connection Cable 219685 (incl. Mi70 Link software) Probe cable diameter 5.5 mm Probe cable lengths 2 m, 5 m or 10 m Housing material G-AlSi 10 Mg (DIN 1725) Housing classification IP 65 (NEMA 4X) ± 0.005 %/°C full scale RL < 500 ohm RL > 2 kohm RL > 10 kohm 89 Mounting options Dimensions Dimensions in mm (inches) Mounting with DIN Rail Installation Kit Pole Installation with Installation Kit for Pole or Pipeline Mounting with Wall Mounting Kit Mounting Rain Shield with Installation Kit Don’t measure the damage. Prevent it. HUMICAP® is a registered trademark of Vaisala. New intelligence for measuring moisture in oil. On-line, real time measurement ▪ without sampling ▪ ▪ Installation through ball valve – no need to shut down the process High stability in extreme conditions Know your oil better – Vaisala HUMICAP® instruments! Download the 'Top 8 FAQs - Measuring moisture in oil' at www.vaisala.com/mioFAQ Instruments display water activity trends. TYPE APPROVED PRODUCT CERTIFICATE NO.: A-11440 For more information, visit www.vaisala.com or contact us at [email protected] 90 Ref. B210953EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com/mioFAQ [email protected] 91 www.vaisala.com MMT310 Series Moisture and Temperature Transmitter for Oil Technical data Measured values General WATER ACTIVITY Water content as ppm calculation for transformer oils PPM units are traditionally used in transformer applications. They indicate the average mass concentration of water in oil. The ppm calculation for mineral oil based transformer oil is optional in the MMT310 series. Diverse applications and demanding conditions The MMT310 series can be used in lubrication and hydraulic systems as well as in transformers. It can be used for on-line moisture monitoring and as a control function, allowing separators and oil purifiers to be started only when necessary. Two probe options: MMT317 and MMT318 ▪ Continuous measurement of moisture in oil ▪ The Vaisala HUMICAP® Moisture and Temperature Transmitter Series for Oil MMT310 is a fast and reliable online detector for moisture in oil. Proven Vaisala HUMICAP® sensor, 10 years in oil applications Reliable Vaisala HUMICAP® technology ▪ Measurements in lubrication, hydraulic and transformer oils ▪ Excellent pressure and temperature tolerance ▪ Measuring water activity - ppm calculation for transformer oil ▪ ▪ ▪ Small size, easy to integrate Features/Benefits The MMT310 series incorporates the latest generation of the Vaisala HUMICAP® Sensor, developed for demanding moisture measurement in liquid hydrocarbons. The sensor’s excellent chemical tolerance provides accurate and reliable measurement over the wide measurement range. NIST traceable calibration Applications: e.g. monitoring of transformer oil and of lubrication systems in marine and paper industry Measuring water activity The MMT310 series measures moisture in oil in terms of the water activity (aw) and temperature (T). Water activity directly indicates if there is a risk of free water formation. The measurement is independent of oil type, age, and temperature. 92 Installation options The MMT318 has two adjustable probe lengths. The transmitter can be ordered with a ball valve set that enables the insertion and removal of the moisture probe for calibration, without the need to empty the oil system. Measurement range aw Accuracy (including non-linearity, hysteresis and repeatability) 0 ... 0.9 0.9 ... 1.0 Response time (90 %) at +20 ˚C in still oil (with stainless steel filter) Sensor 0 ... 1 ±0.02 ±0.03 10 min Vaisala HUMICAP® TEMPERATURE Measurement range Typical accuracy at +20 ˚C Typical temperature dependence of electronics Sensor -40 ... +180 ˚C (-40 ... +356 ˚F) ±0.1 ˚C (±0.18 ˚F) ±0.05˚C/ ˚C (±0.005 ˚F/˚F) Pt100 IEC751/3 class B Electrical connections Two analog outputs, selectable and scalable 0 ... 20 mA or 4 ... 20 mA Typical accuracy of analog output at +20 ˚C ±0.05 % full scale Typical temperature dependence 0.005 %/˚C (0.003 %/˚F) of analog output full scale Serial output RS-232C Connections 8-pole connector with RS-232C, current outputs (two channels) and Uin Operating voltage Uin 24 VDC (10 ... 35 VDC) Minimum operating voltage Uin with RS-232C 10 VDC 11 VDC + (Rload/60) VDC Iout 0 ... 20 mA, 4 ... 20 mA Power consumption at +20 ˚C, Uin = 24 VDC with RS-232C 20 mA 60 mA Iout 2 x 0 ... 20 mA Operating temperature range for electronics -40 ... +60 ˚C (-40 ... +140 ˚F) Storage temperature -55 ... +80 ˚C (-67 ... +176 ˚F) Pressure range for MMT318 with ball valve up to 120 ˚C 0 ... 40 bar Pressure range for MMT317 0 ... 10 bar External load R1<500 Ohm Material transmitter housing G-AlSi 10 Mg transmitter base ABS/PC Housing classification IP65 to be protected from direct rain Cable feed through alternatives 8-pole connector with 5 m cable, female 8-pin connector screw joint for cable diameter 4 ... 8 mm Sensor protection stainless steel grid Probe cable length MMT317 0.5, 2, 5 or 10 meters MMT318 2, 5 or 10 meters Probe installation MMT317 Swagelok® NPT 1/2”, ISO 3/8” or ISO 1/2” Probe installation MMT318 Fitting bodies ISO 1/2”, NPT 1/2” Ball Valve Set BALLVALVE-1 Complies with EMC standard EN61326-1, Industrial environment Note: When using the current output, the RF field susceptibility level according to standard EN61000-4-3 with a frequency band of 110 ... 165 MHz, is only 3 V/m (generic environment) with the specified accuracy. HUMICAP® is a registered trademark of Vaisala. The MMT317 has a small pressuretight probe with optional Swagelok fittings. Several outputs, one connector The MMT310 series has two analog outputs and an RS-232 serial output. The output signals and the supply power travel in the same cable, the only cable connected to the unit. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210831EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 93 www.vaisala.com MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM Applications Water activity measurement The MMT162 measures moisture in oil in terms of the water activity (aw) and temperature (T). Water activity directly indicates whether there is a risk of free water formation. The measurement is independent of oil type, age and temperature. The ppm calculation for mineral oil based transformer oil is optional in the MMT162. Several outputs - one connector The MMT162 enables on-line moisture monitoring in oils even in the most demanding applications. Features/Benefits ® The Vaisala HUMICAP Moisture and Temperature Transmitter for Oil MMT162 is an excellent economical solution for reliable on-line detection of moisture in oil. ▪ Continuous measurement of moisture in oil ▪ Measures in lubrication, hydraulic and transformer oils ▪ Excellent pressure and temperature tolerance Reliable Vaisala HUMICAP ® technology ▪ Vaisala HUMICAP® Sensor - proven in the field since 1973 ▪ Measures water activity - ppm-calculation available for transformer oil The MMT162 incorporates the latest generation of the Vaisala HUMICAP® Sensor. The sensor is developed for demanding moisture measurement in liquid hydrocarbons and has been successfully used in oil applications for over a decade. The sensor’s excellent chemical tolerance provides accurate and reliable measurement over the measurement range. ▪ ▪ Small size, easy to integrate NIST traceable calibration (certificate included) The MMT162 has two analog outputs that can be scaled and the measurement ranges changed. Additionally, the transmitter has an RS-485 serial output. The signals and the unit power travel in the same cable. Technical data Measured Values General WATER ACTIVITY Sensor HUMICAP® Cable connections (2 ports) M8, 4 pin Minimum operating voltage with RS-485 output 14 ... 28 VDC voltage output 16 ... 28 VDC current output 22 ... 28 VDC Supply current normal measurement 20 mA + load current External load for voltage output min. 10 kOhm current output max. 500 Ohm Housing material metal AISI 316L plastic PPS + 40% GF Mechanical connections with bonded seal ring (washer) metal version G 1/2’’ ISO or NPT 1/2’’ plastic version G 1/2’’ ISO Housing classification IP65 (NEMA 4) Storage temperature range -40 ... +80 °C (-40 ... +176 °F) Weight with plastic housing 65 g (2.3 oz) with metal housing 200 g (7 oz) Complies with EMC standard EN61326-1, Electrical equipment for measurement control and laboratory use - EMC requirements; Industrial environment Measurement range 0 ... 1 aw Accuracy (including non-linearity, hysteresis and repeatability) 0 ... 0.9 ± 0.02 0.9 ... 1.0 ± 0.03 Response time in oil flow (typical) <1 min (dry-wet) MOISTURE Calculated moisture content in ppm for mineral transformer oil TEMPERATURE Accuracy at +20 °C (+68 °F) ± 0.2 °C (0.36 °F) Operating Environment Operating temperature Oil temperature Pressure range metal version plastic version Oil flow -40 ... +60 °C (-40 ... +140 °F) -40 ... +80 °C (-40 ... +176 °F) up to 200 bar up to 40 bar some flow recommended Outputs Analog outputs (two channels) current output voltage output Alarm level indication by analog signal Digital outputs 0 ... 20 mA, 4 ... 20 mA 0 ... 5 V, 0 ... 10 V user selectable RS-485 Stainless steel filter (standard) Stainless steel filter for high flow (>1 m/s) Connection cable for MM70 hand-held meter USB serial interface cable Sealing ring set (U-seal) ISO G1/2, 3 pcs Sealing ring set (copper) ISO G1/2, 3 pcs ISO 1/2’’ plug NPT 1/2’’ plug Sampling cell Sampling cell w. Swagelok connectors Connection cable 2 m (6.5 ft), M8 snap-on 0.32 m (1 ft) Shielded, M8 threaded 3.0 m (9.8 ft), Shielded, M8 threaded 5.0 m (16.4 ft), Shielded, M8 threaded 10 m (32.8 ft), Shielded, M8 threaded 3 m, Shielded, connector 90° angle 5 m, Shielded, connector 90° angle M8 threaded, Ch1 signal + Ch2 LED An optional LED-cable enables a visual alarm. Compact, rugged and intelligent Due to its compact size, the MMT162 is quickly and easily installed in tight spaces. Units are delivered fully assembled, however, you can reconfigure them to suit your needs. MM70 In combination with an MM70 indicator, the MMT162 provides an ideal tool for on site calibration. The MI70 indicator can be used as a display, communication, and datalogging device for the MMT162. For more information, visit www.vaisala.com or contact us at [email protected] 94 Options and accessories 221494SP 221493SP 219980 219690 221525SP 221524SP 218773 222507 DMT242SC DMT242SC2 211598 HMP50Z032 HMP50Z300 HMP50Z500 HMP50Z1000 221739 221740 MP300LEDCBL Ref. B210755EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 95 MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in Oil Numerical and graphical display The MM70 features a multilingual, menu-based user interface and a backlit LCD display. The measurement parameters can be numerically and graphically displayed and logged into the meter's memory at the same time. An analog output option is also available. The MM70 is an ideal tool for the preventive maintenance of oil-filled systems.The water activity measurement indicates the margin to free water formation, which causes severe problems in lubrication systems. Features/Benefits ▪ Measurement independent of oil type, age and temperature ▪ In-line process checking through ball valve, no need to drain the oil ▪ Rugged and reliable construction ▪ Excellent pressure and temperature tolerance ▪ Data can be logged and transferred to a PC ▪ Vaisala HUMICAP® Sensor proven field performance since 1973 ▪ Compatible with Vaisala’s fixed oil moisture instruments ▪ No reference oil needed for recalibration ▪ NIST traceable (certificate included) 96 The Vaisala HUMICAP® Hand-held Moisture Meter for Oil MM70 enables reliable detection of moisture in oil. In-line process checking through ball valve The probe can be inserted directly into the process pipe through a ball valve without draining the oil in the system. Water activity measurement The MM70 measures moisture in oil in terms of the water activity (aw) and temperature (T). Water activity directly indicates whether there is a risk of free water formation. The measurement is independent of oil type, age and temperature. ppm calculation included The MM70 has an embedded model for expressing moisture as ppm in mineral transformer oil. The customer can enter up to three other oil models into the meter’s memory. Connection to PC The optional MI70 Link Windows® software in combination with a USB connection cable is used to transfer logged data and real time measurement data from the MM70 to a PC. Proven Vaisala HUMICAP® technology The MM70 incorporates the latest generation of the Vaisala HUMICAP® Sensor, developed for demanding moisture measurements in liquid hydrocarbons. The sensor’s excellent chemical tolerance provides accurate and reliable measurement over the measurement range. Speedy service once a year The meter can be recalibrated by sending the probe to Vaisala Service, or customers can calibrate the instrument themselves using a standard relative humidity calibration. Multi-probe operation One or two probes can be connected simultaneously. Maintenance teams can use additional Vaisala dewpoint or relative humidity probes for other tasks. For example, a dewpoint probe is ideal for checking the moisture inside washed and dried oil tanks. Technical data Performance Display WATER ACTIVITY Measurement range aw 0 ... 1 Accuracy (including nonlinearity, hysteresis and repeatability) When calibrated against salt solutions (ASTM E104-85): 0 ... 0.9 ±0.02 0.9 ... 1.0 ±0.03 Maximum achievable accuracy when calibrated against high-quality, certified humidity standards: 0 ... 0.9 ±0.01 0.9 ... 1.0 ±0.02 Response time (90%) at +20 °C (+68 °F) in still oil (with stainless steel filter) 10 min. Sensor Vaisala HUMICAP® Recommended recalibration interval 1 year TEMPERATURE Measurement range Typical accuracy at +20 °C Typical temperature dependence of electronics Sensor Typical long-term stability -40 ... +100 °C (-40 ... +212 °F) ±0.2 °C (±0.36 °F) ±0.005 °C/°C (±0.005 °F/°F) Pt 100 IEC 751 1/3 class B better than 0.01 aw / year Operating environment PROBE Operating temperature range for electronics Operating pressure range during installation through ball valve Oil flow range -40 ... +60 °C (-40 ... +140 °F) max. 20 bar max. 10 bar max. 1 m/s INDICATOR Operating temperature range Operating humidity range -10 ... +40 °C (+14 ... +104 °F) non-condensing ELECTROMAGNETIC COMPATIBILITY Complies with EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements; Portable equipment. LCD with backlight, graphic trend display of any parameter, character height up to 16 mm Analog output 0 ... 1 VDC Output resolution 0.6 mV PC interface MI70 Link software with USB or serial port cable Data logging capacity 2700 points Alarm Audible alarm function Mechanics PROBE Housing classification IP65 (NEMA 4) Housing material ABS/PC blend Probe material Stainless steel (AISI316L) Cable length between probe and indicator 1.9 m, 10 m extension available Weight 506 g INDICATOR Housing classification Weight Probe inputs IP54 400 g 1 or 2 Options and accessories Carrying case MI70CASE2 Ball valve set (incl. fitting body & blanking plug) HMP228BVS Probe cable extension, 10 m 213107SP Transmitter connection cables for HMP228 27159ZZ MMT318 DRW216050 MMT/HMT330/DMT340 211339 MI70 Link software with USB cable 219687 MI70 Link software with serial port cable MI70LINK Analog output cable 27168ZZ Sensor protection HM47453SP Dewpoint measurement probes DMP74A/B Relative humidity measurement probes HMP75, HMP76, HMP77 Dimensions Dimensions in mm (inches) Inputs and outputs Power supply Rechargeable NiMH battery pack with AC-adapter or 4xAA-size alkalines, type IEC LR6 Battery operation time continuous use 48 h typical at +20 °C (+68 °F) data logging use up to a month, depending on logging interval Menu languages English, Chinese, Spanish, French, German, Japanese, Russian, Swedish, Finnish R1/2" ISO 7/1 www.vaisala.com Adjustment range 250 mm HUMICAP® is a registered trademark of Vaisala. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210960EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 97 Carbon Dioxide www.vaisala.com GMP343 Carbon Dioxide Probe for Demanding Measurements Features/Benefits ▪ ▪ Excellent accuracy and stability ▪ A single-beam, dualwavelength CO2 measurement with no moving parts ▪ Vaisala CARBOCAP® Sensor, a silicon-based non-dispersive infrared (NDIR) sensor Compensation options for temperature, pressure, humidity and oxygen Technical data PRESSURE Inputs and outputs Effect on accuracy with pressure compensation: 0 ... 1000 ppm 0 ... 2000 - 2 % CO2 range options Pressure (hPa) Accuracy (% of reading) 900 ... 1050 ±0.5 ±1 700 ... 1300 ±1 ±2 Integrated pressure sensor is not included in GMP343 Operating voltage Power consumption without optics heating with optics heating Long term stability easy moderate harsh see graph below <±2 % of reading / year <±2 % of reading / 6 months <±2 % of reading / 3 months GMP343 OPERATING CONDITIONS 11 ... 36 VDC <1 W <3.5 W ANALOG OUTPUTS Current output range resolution max. load Voltage output range resolution min. load 4 ... 20 mA 14 bits 800 Ohm @ 24 VDC, 150 Ohm @ 10 VDC 0 ... 2.5 V, 0 ... 5 V 14 bits (13 bits with 0 ... 2.5 V) 5 kOhm RS485, RS232 DIGITAL OUTPUTS ▪ Low power consumption and heat emission ▪ ▪ Designed for outdoor use Materials Response time (90 %) Compact and lightweight DIFFUSION MODEL Filter attached Yes Yes No No The GMP343 is available as an open-path diffusion-aspirated model (left) and as a flow-through model (right). Averaging (s) 0 30 0 30 Response (s) 75 82 <2 30 Averaging (s) 0 30 0 30 Response (s) 26 44 8 23 Housing Filter cover IP classification Housing (cable attached) Diffusion filter (weather protection) Diffusion filter (sintered PTFE) Cable connector type Weight (probe only) anodized aluminium PC <1 W IP67 IP65 IP66 8-pin M12 360 g FLOW-THROUGH MODEL ® The Vaisala CARBOCAP Carbon Dioxide Probe GMP343 is an accurate and rugged probe-type instrument for ecological measurements. Typical applications include CO2 soil respiration, ambient CO2 monitoring, plant growth chambers, and OEM applications. The GMP343 can output both numerically filtered and raw measurement data and it can also compensate the measurement with an internal temperature measurement and user-set relative humidity, pressure and oxygen values. Technical data Performance Measurement range options 0 ... 1000 ppm, 0 ... 2000 ppm, 0 ... 3000 ppm, 0 ... 4000 ppm, 0 ... 5000 ppm, 0 ... 2 % Accuracy (excluding noise) at 25 °C (77 °F) and 1013 hPa after factory calibration with 0.5 % accurate gases with different range options 0 ... 1000 ppm ±(3 ppm + 1 % of reading) 0 ... 2000 ppm - 0 ... 2 %* ±(5 ppm + 2 % of reading) *Accuracy below 200 ppm CO2 not specified for 2 % range option In combination with an MI70 indicator, the GMP343 provides a tool for accurate in-situ measurement. The MI70 can be used as a display, communication and data logging device. Noise (repeatability) at 370 ppm CO2 with no output averaging with 30 s output averaging Each GMP343 is calibrated using ±0.5 % accurate gases at 0 ppm, 200 ppm, 370 ppm, 600 ppm, 1000 ppm, 4000 ppm and 2 %. Calibration is also done at temperature points of -30 °C, 0 °C, 25 °C and 50 °C. If needed, the customer can recalibrate the instrument using the multipoint calibration (MPC) feature allowing up to 8 user-defined calibration points. TEMPERATURE 98 Effect on accuracy with temperature compensation: CO2 range options 0 ... 1000 ppm 0 ... 2 000 - 5000 ppm Temperature °C (°F) Accuracy (% of reading) +10 ... +40 (+50 ... +104) ±1 ±1 +40 ... +60 (+104 ... +140) ±2 ±3 -40 ... +10 (-40 ... +50) ±3 ±3 ±3 ppm CO2 ±1 ppm CO2 0 ... 2 % ±2 ±4 ±5 ±5 ppm CO2 For readings below 200 ppm CO2 Temperature compensation is performed by an integrated Pt1000 element Gas flow (l/min) 0.3 0.3 1.2 1.2 Warm-up time full accuracy ±0.5 % full accuracy 10 min 30 min Operating Environment Temperature operating -40 ... +60 °C (-40 ... +140 °F) storage -40 ... +70 °C (-40 ... 158 °F) Humidity see graph ‘GMP343 Operating Conditions’ Pressure compensated range 700 ... 1300 hPa operating <5 bar Gas flow for flow-through model 0 ... 10 liters/min Electromagnetic compatibility EN61326, Generic Environment For more information, visit www.vaisala.com or contact us at [email protected] Options and accessories Wall mount bracket GMP343BRACKET Mounting flange GMP343FLANGE Standard diffusion filter (weather protection, IP65) +filter cover GMP343FILTER Diffusion filter (sintered PTFE filter, IP66) + filter cover 215521 Calibration adapter (for the diffusion model) GMP343ADAPTER Junction box JUNCTIONBOX-8 Probe cables 2m GMP343Z200SP 6m GMP343Z600SP 10m GMP343Z1000SP PC connection cable, 2m 213379 MI70 connection cable, 2m DRW216050SP USB adapter (USB-D9 Serial connection cable) 219686 Soil adapter kit for horizontal positioning 215519 Soil adapter kit for vertical positioning 215520 Ref. B210688EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 99 www.vaisala.com GMT220 Series Carbon Dioxide Transmitters for Industrial Applications Technical data Performance Operating environment Measurement Ranges GMT221 for high concentrations 0 ... 2 % 0 ... 3 % 0 ... 5 % 0 ... 10 % 0 ... 20 % GMT222 for low concentrations Accuracy (including repeatability, non-linearity and calibration uncertainty) at 25 °C and 1013 hPa GMT221 ±(1.5 % of range + 2 % of reading) (applies for concentrations above 2 % of full scale) GMT222 ±(1.5 % of range + 2 % of reading) Temperature dependence, typical -0.3 % of reading / °C Pressure dependence, typical +0.15 % of reading/hPa Long-term stability <±5 %FS/2 years Response time (63 %) GMT221 20 seconds GMT222 30 seconds Warm-up time 30 seconds, 15 minutes full specifications The GMT220 transmitters withstand harsh and humid environments. Features/Benefits ▪ ▪ ▪ ▪ ▪ Incorporates Vaisala CARBOCAP® - the siliconbased NDIR sensor IP65 protected against dust and spray water Several measurement ranges Easy installation Standard analog outputs and two configurable relays available Applications include: ▪ ▪ Horticulture and fruit storage ▪ Safety alarming and leakage monitoring ▪ Demand controlled ventilation in harsh environments Greenhouses and mushroom farming 100 The Vaisala CARBOCAP® Carbon Dioxide Transmitter Series GMT220 is designed to measure carbon dioxide in harsh and humid environments. The housing is dust- and waterproof to IP65 standards. The GMT220 series transmitters incorporate the advanced Vaisala CARBOCAP® Sensor. The patented sensor has unique reference measurement capabilities. Its critical parts are made of silicon; this gives the sensor outstanding stability over both time and temperature. By lengthening the calibration intervals, the user saves both time and money. Interchangeable probes The user has a choice of measurement ranges up to 20% of CO2. The GMT221 is for higher concentrations of CO2 and the 0 ... 2000 ppm 0 ... 3000 ppm 0 ... 5000 ppm 0 ... 7000 ppm 0 ... 10 000 ppm GMT222 for lower concentrations of CO2. The GMT220 probes are interchangeable. They can be removed and reattached or replaced at any time – without the need for calibration and adjustment. The probes can be attached directly to the transmitter body or, when used with a cable, installed remotely into hard-to-reach places or areas with dangerously high levels of CO2. The interchangeability of the GMT220 transmitter’s probes truly facilitates field maintenance. Inputs and outputs Outputs Resolution of analog outputs Recommended external load: current output voltage output Two pre-or user-defined relay outputs Relay contacts Connections Operating voltage Power consumption 0 ... 20 or 4 ... 20 mA and 0 ... 10 V 12 bits max. 400 Ohm min. 1 kOhm Operating temperature with display Storage temperature Humidity Electromagnetic compatibility -20 ... +60 °C (-4 ... +140 °F) 0 ... +50 °C (+32 ... +122 °F) -30 ... +70 °C (-22 ... +158 °F) 0 ... 100 %RH, non-condensing EN61326-1, Generic Environment Mechanics Housing material transmitter body probe Housing classification Weight: GMT221 GMT222 Probe cable length ABS plastic PC plastic IP65 max. 280 g max. 300 g 2 m and 10 m (optional) Accessories Spare probe GMP221, GMP222 (use the order form to define measurement range etc.) Clips (2 pcs) for attaching the probe 25245GM Mounting flange for the probe GM45156 Probe cables 2m 25665GMSP 10 m 210848GMSP Calibrator for interchangeable probes GMK220 Wall Assembly Plate GM45160 In-soil adapter for probe 211921GM Serial COM adapter 19040GM Calibration adapter for probe 26150GM max. 30VAC/60VDC, 0.5A screw terminals, 0.5 ... 1.5 mm2 nominal 24 VAC/DC <4 W The end user can carry out field maintenance without any additional equipment or heavy and expensive calibration gas bottles by simply replacing a probe. Probes that have been replaced can be sent to Vaisala for recalibration. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210827EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 101 www.vaisala.com GMM220 Carbon Dioxide Modules for Demanding OEM Applications Technical data Carbon dioxide Mechanics Measurement ranges GMM221 for high concentrations Probe housing material PC plastic Housing classification (probe only) IP65 Weight: GMM221 (w/2m cable) max. 180 g Weight: GMM222 (w/2m cable) max. 200 g Probe cable length 0.6 m, 1 m (high temperature cable), 2 m, 6 m or 10 m (optional) 0 ... 2 %, 0 ... 3 %, 0 ... 5 %, 0 ... 10 %, 0 ... 20 % GMM222 for low concentrations 0 ... 2000 ppm, 0 ... 3000 ppm, 0 ... 5000 ppm, 0 ... 7000 ppm, 0 ... 10 000 ppm Accuracy (including repeatability, non-linearity and calibration uncertainty) at 25 °C and 1013 hPa GMM221 ±(1.5% of range + 2% of reading) (applies for concentrations above 2% of full scale) GMM222 ±(1.5% of reading + 2% of reading) Temperature dependence, typical -0.3 % of reading / °C Pressure dependence, typical +0.15% of reading hPa Long-term stability <±5 %FS/2 years Response time (63 %) GMM221 20 seconds GMM222 30 seconds Warm-up time 30 seconds, 15 minutes full specifications Accessories Spare probe GMP221, GMP222 (use the order form to define measurement range etc.) Clips (2 pcs) for attaching the probe 25245GM Mounting flange for the probe GM45156 GMK220 CO2 Calibration Unit Probe cables 1 m high temperature probe cable (180 °C / 365 °F) GMM220Z100SP 2 m probe cable GMM220Z200SP 6 m probe cable GMP343Z600SP 10.0 m probe cable GMP343Z1000SP Serial COM adapter 19040GM Dimensions Dimensions in mm (inches) The Vaisala CARBOCAP® Carbon Dioxide Module Series GMM220 withstand harsh conditions.They provide high carbon dioxide measurement accuracy over wide temperature and relative humidity ranges. Features/Benefits ▪ Incorporates Vaisala CARBOCAP® - the silicon based CO2 sensor ▪ Choice of several measurement ranges ▪ IP65 protected probe against dust and spray water ▪ Interchangeable probes provide easy maintenance ▪ Modules optimized for integration into equipment for greenhouse control, incubators, fermentors, safety alarming and integrated systems. For harsh environments ® The Vaisala CARBOCAP Carbon Dioxide Module Series GMM220 are designed for Original Equipment Manufacturers (OEM’s) requiring carbon dioxide measurements in harsh and demanding applications. Vaisala CARBOCAP® The GMM220 series modules incorporate the industrial Vaisala CARBOCAP® Sensor. The patented sensor has unique reference measurement capabilities. Its critical parts are made of silicon; this gives the sensor outstanding stability over both time and temperature. Since water vapor, dust, and most chemicals do not affect the measurement, the GMM220 series modules can be used in harsh and humid environments. 102 Inputs and outputs Outputs Interchangeable probes The GMP220 probes are interchangeable. They can be removed, reattached or replaced at any time – without the need for calibration and adjustment. The interchangeable probes make calibration and field service easy. In addition, the measurement range can be changed simply by replacing one probe with another. Different configurations The user has a choice of measurement ranges up to 20 % CO2: the Vaisala CARBOCAP® Carbon Dioxide Module GMM221 for higher and the Vaisala CARBOCAP® Carbon Dioxide Module GMM222 for lower concentrations of CO2. Different power supply voltages, output options, as well as cable lengths, connectors, and mounting gear are also available. 0 ... 20 or 4 ... 20 mA, 0 ... 1 V, 0 ... 2V, 0 ... 2.5 V, or 0 ... 5 V 12 bits Resolution of analog outputs Recommended external load: current output max. 200 Ohm voltage output min. 1 kOhm Operating voltage 11 ... 20 VDC or 18 ... 30 VDC Connections screw terminals, wire size 0.5 ... 1.5 mm2 Power consumption <2.5 W GMP221 GMP222 Operating environment Operating temperature Storage temperature Operating pressure probe mother board Electromagnetic compatibility -20 ... +60 °C (-4 ... +140 °F) -30 ... +70 °C (-22 ... +158 °F) 700 ... 1300 hPa 0 ... 100 %RH, non-condensing 0 ... 85 %RH, non-condensing EN61326-1, Generic Environment For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210856EN-C ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 103 www.vaisala.com Technical data GMM111 Carbon Dioxide Module Dimensions CO2 measurement range 0 ... 5 %, 0 ... 10 % or 0 ... 20 % Accuracy (including repeatability, non-linearity and calibration uncertainty) ±(1.5% of range + 3 % of reading) Long-term stability ±1 % CO2/2 years Response time T90 1 min at 0.5 l/min flow Dimensions in mm Product lifetime 96 Ø3.2 65 no effect 4 % of reading/ l/min -0.3 % of reading/°C +0.15 % of reading/hPa 1 min, 10 min for full specifications > 10 years mA V 0 B A 0 24V TUBE I.D. Ø4 (TUBE O.D. Ø6) 6 Flow rate dependence < 1 l/min flow 1 ... 10 l/min flow Temperature dependence, typical Pressure dependence, typical Warm-up time mA V 0 B A 0 24V 25 Performance 30 60 Operating environment Temperature +5 ... +55 °C (+41 ... +131 °F) Humidity 0 ... 99 %RH non-condensing Pressure 700 ... 1200 hPa Gas flow operating range < 10 l/min recommended range 0.2 ... 0.8 l/min Electromagnetic compatibility Complies with EMS Standard EN61326-1, Generic Environment The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is a CO2 measurement module with flow-through aspiration. Features/Benefits ▪ Compact CO2 module with flow-through aspiration ▪ Ideal for control of CO2 concentrations in incubators ▪ Incorporates Vaisala CARBOCAP®, the silicon based NDIR sensor with unique internal referencing ▪ Advanced single-beam, dual wavelength measurement with no moving parts ▪ Measurement range options 0 ... 5 %, 0 ... 10 % and 0 ... 20 % CO2 ▪ Excellent long-term stability 104 GMM111 The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is designed especially for control of biological processes where high CO2 concentrations are used. It has 3 optional measurement ranges 0 ... 5/10/20 % CO2. The GMM11 is a flow-trough model and has barbed conncectors for attaching the in and out flow tubes. As the module is not mounted in the chamber, the chamber can be heatsterilized without removing the module. The Vaisala CARBOCAP® CO2 sensors have been proven to be accurate anddurable. They have an excellent long-term stability, which decreases maintenance. The superior performance of Vaisala CARBOCAP® sensors results largely from the stable reference provided by the electrically tunable Fabry-Perot Interferometer(FPI). The tunable FPI filter measures CO2 absorption, and simultaneously a reference wavelength. This internal reference measurement compensates effectively for any changes in the optical path, such as light source intensity changes and contamination. In the HVAC market, this type of reference measurement is a unique feature to Vaisala CARBOCAP® products. The true internal reference measurement of Vaisala CARBOCAP® CO2 transmitters provides years of stable CO2 measurements. Inputs and outputs Outputs Operating voltage Power consumption 4 ... 20 mA, 0 ... 10 V RS485, 2-wire, non-isolated 24 V (±20 %) AC/DC <2 W For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210566EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 105 www.vaisala.com GM70 Hand-Held Carbon Dioxide Meter for Spot-Checking Applications accuracy is not affected by dust, water vapor or most chemicals. The GM70 has a two-year recommended calibration interval. The Vaisala CARBOCAP® Hand-Held Carbon Dioxide Meter GM70 is the demanding professional’s choice for hand-held carbon dioxide measurement.The meter consists of the indicator (center) and probe, used either with the handle (left) or pump (right). Features/Benefits ▪ ▪ Proven Vaisala CARBOCAP® reliability Two optional sampling methods: diffusion or pump aspiration ▪ User-friendly meter with multilingual user interface ▪ Numerical and graphical display of measurements ▪ Data can be logged and transferred to PC via MI70 Link software ▪ Wide selection of measurement ranges ▪ Easy recalibration using the interchangeable probes ▪ Suitable for field checking of fixed CO2 instruments ▪ ▪ Short warm-up time Compact and versatile 106 The Vaisala CARBOCAP® Hand-Held Carbon Dioxide Meter GM70 is a user-friendly meter for demanding spot measurements in laboratories, greenhouses and mushroom farms. The meter can also be used in HVAC and industrial applications, and as a tool for checking fixed CO2 instruments. The GM70 has a short warm-up time and is ready for use almost immediately. It has a menu-based interface, a graphical LCD display and data logging capability. The optional MI70 Link Windows® software in combination with a USB connection cable provides an easy way to handle data in a PC environment. Vaisala CARBOCAP ® technology The GM70 incorporates the advanced Vaisala CARBOCAP® sensor that has unique reference measurement capabilities. The measurement Two sampling methods The handle is for hand-held diffusion sampling. The GM70 pump enables pump-aspirated sampling from locations difficult to access otherwise. It is also ideal for comparisons with fixed CO2 transmitters. Interchangeable probes The GM70 uses the same probes as Vaisala CARBOCAP® Carbon Dioxide Transmitter Series GMT220 and Modules Series GMM220. By plugging different probes into the handle or pump, the user can easily change the measurement range of the GM70. The meter can also be used as a calibration check instrument for Vaisala’s GM20 and series, GMT/ M220 fixed CO2 instruments. GMP220 probes can even be adjusted by using the GM70 meter. The GM70 has two probe inputs. Vaisala’s relative humidity and dewpoint probes can also be used simultaneously with CO2 measurement. Technical data CO2 volume concentration measurement MI70 Indicator general Measurement ranges High concentrations short probe (GMP221) Menu languages 0 ... 2 % 0 ... 3 % 0 ... 5 %, 0 ... 10 %, 0 ... 20 % Low concentrations 0 ... 2000 ppm long probe (GMP222) 0 ... 3000 ppm, 0 ... 5000 ppm, 0 ... 7000 ppm, 0 ... 10,000 ppm Accuracy (including repeatability, non-linearity and calibration uncertainty) at 25 °C and 1013 hPa GMP221 ±(1.5% of range + 2% of reading) (applies for concentrations above 2% of full scale) GMP222 ±(1.5% of range + 2% of reading) Temperature dependence, typical -0.3 % of reading / °C Pressure dependence, typical +0.15% of reading/hPa Long-term stability <±5 %FS/2 years Response time (63 %) GMP221 20 seconds GMP222 30 seconds Warm-up time 30 seconds, 15 minute full specifications Max. no. of probes Power supply Analog output Output resolution PC interface Data logging capacity Alarm Operating temperature range Operating humidity range Housing material Housing classification Weight Battery operation time Measurement environment Temperature Relative humidity Operation pressure Flow range (diffusion sampling) Display English, Chinese, French, Spanish, German, Japanese, Russian, Swedish, Finnish LCD with backlight, graphic trend display of any parameter, character height up to 16 mm 2 Rechargeable NiMH battery pack with AC-adapter 0 ... 1 VDC 0.6 mV MI70 Link software with USB or serial port cable 2700 points Audible alarm function -10 ... +40 °C (+14 ... +104 °F) non-condensing ABS/PC blend IP54 400 g -20 ... +60 °C (-4 ... +140 °F) 0 ... 100 %RH non-condensing 700 ... 1300 hPa 0 ... 10 m/s Continuous use with handle with pump Data logging use better than 8h at +20 °C (+68 °F) better than 5h at +20 °C (+68 °F) without load up to a month, depending on logging interval Electromagnetic compatibility EN 61326-1, Portable Equipment. Probe, handle & pump general Sensor Housing material GMP221/222 probe GMH70 handle GM70 Pump Storage temperature Storage humidity Weight GMH70 with GMP221/222 probe GM70 Pump with GMP221/222 probe Vaisala CARBOCAP® PC plastic ABS/PC blend aluminium casing -30 ... +70 °C (-22 ... +158 °F) 0 ... 100 %RH non-condensing For more information, visit www.vaisala.com or contact us at [email protected] 230 g 700 g Accessories Connection cable for fixed CO2 instruments GMT220, GMM220, GMD20 and GMW20 GMA70 MI70 Link software with USB cable 219687 MI70 Link software with serial port MI70LINK cable Analog output cable for 0 ... 1 VDC 27168ZZ Calibration adapter 26150GM Carrying case MI70CASE Battery, NiMH 4.8V 26755 Spare probe GMP221, GMP222 (use the order form to define measurement range etc.) Nafion Membrane Tubing 212807GM Ref. B210824EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 107 Dimensions from the stable reference provided by the electrically tunable Fabry-Perot Interferometer (FPI). Features/Benefits ▪ Compact, wall-mounted transmitter for demandcontrolled ventilation ▪ Incorporates Vaisala CARBOCAP®, the silicon based NDIR sensor with unique internal referencing ▪ Advanced, single-beam, dual wavelength measurement with no moving parts ▪ ▪ Excellent long-term stability Ideal for ventilation control in all types of occupied spaces Most of us spend 90 % of our time indoors. Consequently, good indoor air quality is important to our wellbeing. All human beings produce carbon dioxide gas by respiration, thus the carbon dioxide level can be used as an indicator for indoor human presence. A high CO2 level is a sign of poor ventilation and often an indication of other unpleasant odors in the air. In many buildings the ventilation need varies throughout the day. Demand controlled ventilation is an economical way to ensure good air quality. The Vaisala CARBOCAP® CO2 sensors have been proven to be accurate and durable. They have an excellent long-term stability, which decreases maintenance. The superior performance of Vaisala CARBOCAP® sensors results largely 108 The GMW115 Transmitter is designed especially for DCV (Demand Controlled Ventilation) applications with two optional CO2 measurement ranges of 0…2000 ppm and 0…5000 ppm. 60 .2 60 R2.1 Operating environment Temperature -5 ... +45 °C (23 ... 113 °F) Humidity 0 ... 85 %RH Pressure 700 ... 1200 hPa Electromagnectic compatibility Complies with EMS standard EN61326-1, Generic Environment 84 Inputs and outputs Operating voltage Power consumption Outputs 120.9 Ø4 R3.5 The Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW115 is a wall-mounted CO2 transmitter for demand-controlled ventilation. The tunable FPI filter measures CO2 absorption, and simultaneously a reference wavelength. This internal reference measurement compensates effectively for any changes in the optical path, such as light source intensity changes and contamination. In the HVAC market, this type of reference measurement is a unique feature to Vaisala CARBOCAP® products, distinguishing them from competitors’ comparative products that do not have a reference measurement at all, or have an indirect reference measurement, which is based on an assumed background CO2 levels. In buildings with around-the-clock occupancy (e.g. hospitals, work-places, residential buildings, retirement homes), the assumed background CO2 level reference is simply not applicable. The true internal reference measurement of Vaisala CARBOCAP® CO2 transmitters provides years of stable CO2 measurements. 66.3 124 Product lifetime Dimensions in mm 66.7 Accuracy (including repeatability, nonlinearity and calibration uncertainty) Long-term stability Response time T90 Temperature dependence, typical Pressure dependence, typical Warm-up time 0 ... 2000 ppm 0.....5000 ppm ±(2 % of range + 2 % of reading) ± 5 % of range/5 years 1 min -0,35 % of reading / °C +0,15 % of reading/hPa 1 min, 10 min for full. specification > 10 years 85 .3 CO2-measurement range 83.4 Performance 25.8 GMW115 Carbon Dioxide Transmitter for Demand-controlled Ventilation Technical data 85.2 www.vaisala.com 24 V (±20 %) AC/DC <2 W 4 … 20 mA, 0 … 10 V, RS-485, 2-wire, non-isolated Housing Material: Colour: Fire resistance: Ingress protection: ABS plastics Cycolac 233599/NCS 0502-G50Y UL94 HB IP30 For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210568EN-D ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 109 affected by dust, water vapor and most chemicals. Versatile transmitters The GMD/W20 series transmitters can be used independently, or incorporated into building energy management systems. The series consists of duct mount units GMD20/D and wall mount units GMW21/D and GMW22/D. Version D has a display. The two sizes in the wall-mount series make them easy to install for most standard junction boxes. The GMD/W20 series transmitters are designed for use in ventilation-related applications. Features/Benefits ▪ ▪ ▪ Versatile transmitters ▪ ▪ Excellent long-term stability ▪ Ease of installation Duct and wall mount models Incorporates Vaisala CARBOCAP® Sensor - the silicon-based NDIR sensor Negligible temperature dependence The duct mounted Vaisala CARBOCAP® Carbon Dioxide Transmitter Series GMD20 and wall mounted GMW20 are specially designed for Demand Controlled Ventilation (DCV). They are easy to install and require no maintenance. The recommended calibration interval is five years. Vaisala CARBOCAP® technology The GMD/W20 Series Transmitters use the silicon-based Vaisala CARBOCAP® Sensor. The simple structure and reference measurement capabilities make this Single-Beam, Dual-Wavelength NDIR sensor extremely stable and reliable. The temperature and flow dependences of the sensor are negligible. In addition, the measurement accuracy is not 110 The duct units' compact sensor head design requires only a small hole in a ventilation duct, thereby minimizing the risk of leaking gaskets and measurement errors. In addition to the standard 0 ... 20 mA, 4 ... 20 mA and 0 ... 10 V outputs, there are three other options: two LonWorks® interfaces and a relay output. The relay output is standard with the display units. Improve indoor air at minimal energy costs The use of the GMD/W20 series transmitters ensures the best possible control of air quality and results in considerable savings in energy consumption, maintenance and recalibration costs. Temperature option The GMA20T temperature module, an option with the GMW21 wall mount unit, combines both CO2 and temperature measurement into one transmitter. The GMA20T has an output of 0 ... 10 V corresponding to a temperature range of 0 ... +50 °C (+32 ... +122 °F). Performance Accessories and options CARBON DIOXIDE MEASUREMENT Display and relay option for GMD/W21/22 Relay output option LonWorks® module with CO2 signal (Not available when display option is added) LonWorks® module with both CO2 signal and temperature signals (Not available when display option is added) Serial COM adapter Analog temperature module for GMW21 (not available when display option is added) Hand-held meter for field verification Measurement range 0 ... 2000 ppm (nominal; can be calibrated for other ranges: 0 ... 5000 ppm, 0 ... 10,000 ppm, 0 ... 20,000 ppm) Accuracy (including repeatability, non-linearity and calibration uncertainty) ± (2 % of range + 2% of reading) Long-term stability <±5 % of range / 5 years Response time (63%) 1 minute Warm-up time 1 minute, 15 minutes full specifications TEMPERATURE MEASUREMENT (OPTIONAL WITH GMW21) Output signal Corresponding measurement range Accuracy at +25 °C Warm up time Temperature sensor 0 ... 10V 0 ... +50 °C (+32 ... +122 °F) ±0.5 °C (0.9 °F) 30 min Semiconductor IC GMI21 GMR20 GML20 GML20T 19040GM GMA20T GM70 Dimensions Dimensions in mm GMD20 and GMD20D Inputs and outputs Outputs Optional outputs 0 ... 20 or 4 ... 20 mA and 0 ... 10 V relay LonWorks® interface 8 bits Resolution of analog outputs Recommended external load: current output max. 500 ohm voltage output min. 1 kohm Operating voltage nominal 24 VAC/DC (18 ... 30 VDC) Connections screw terminals, wire size 0.5 ... 1.5 mm2 Power consumption <2.5 W 80 GMW21 and GMW21D Operating environment Temperature Humidity Flow velocity (GMD20) Electromagnetic compatibility 4 2 2 2 42 GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications Technical data -5 ... +45 °C (+23 ... +113 °F) 0 ... 85 %RH, non-condensing 0 ... 10 m/s EN61326-1, Generic Environment 60 108.5 www.vaisala.com 83 66.7 Mechanics Housing material ABS plastic Housing classification (GMD20 electronics housing) IP65 Housing colour GMW21/22 NCS 0502-G50Y Weight: GMD20 (D) 140 g (170 g) GMW21 (D) 100 g (130 g) GMW22 (D) 90 g (120 g) GMW22 and GMW22D 60 CARBOCAP® is a registered trademark of Vaisala. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210910EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 111 Dimensions Features/Benefits ▪ Compact, OEM module for demand-controlled ventilation and other CO2 measurement applications ▪ Incorporates Vaisala CARBOCAP®, the silicon based NDIR sensor with unique internal referencing ▪ Advanced, single-beam, dual wavelength measurement with no moving parts ▪ ▪ Excellent long-term stability Ideal for ventilation control in all types of occupied spaces Accuracy (including repeatability, nonlinearity and calibration uncertainty) Long-term stability Response time T90 Temperature dependence, typical Pressure dependence, typical Warm-up time Product lifetime 0 ... 2000 ppm 0 ... 5000 ppm 0 ... 10000 ppm ± (2 % of range + 2 % of reading ± 5 % of range/5 years 1 min -0,35 % of reading / °C +0,15 % of reading/hPa 1 min, 10 min for full. specification > 10 years Operating environment Temperature -5 ... +45 °C (23 ... 113 °F) Humidity 0 ... 85 %RH Pressure 700 ... 1200 hPa Electromagnectic compatibility Complies with EMS standard EN61326-1:1997 + Am1:1998, Generic Environment Inputs and outputs Operating voltage Power consumption Outputs The Vaisala CARBOCAP® Carbon Dioxide Module GMM112 is a basic CO2 measurement module. Most of us spend 90% of our time indoors. Consequently, good indoor air quality is important to our wellbeing. All human beings produce carbon dioxide gas by respiration, thus the carbon dioxide level can be used as an indicator for indoor human presence. A high CO2 level is a sign of poor ventilation and often an indication of other unpleasant odors in the air. In many buildings the ventilation need varies throughout the day. Demand controlled ventilation is an economical way to ensure good air quality. The Vaisala CARBOCAP® CO2 sensors have been proven to be accurate and durable. They have an excellent long-term stability, which decreases maintenance. The 112 superior performance of Vaisala CARBOCAP® sensors results largely from the stable reference provided by the electrically tunable Fabry-Perot Interferometer (FPI). The tunable FPI filter measures CO2 absorption, and simultaneously a reference wavelength. This internal reference measurement compensates effectively for any changes in the optical path, such as light source intensity changes and contamination. In the HVAC market, this type of reference measurement is a unique feature to Vaisala CARBOCAP® products, distinguishing them from competitors’ comparative products that do not have a reference measurement at all, or have an indirect reference measurement, 24 V (±20 %) AC/DC <2 W 4 … 20 mA, 0 … 10 V, RS-485, 2-wire, non-isolated Dimensions in mm mA V 0 B A 0 24V mA V 0 B A 0 24V Ø3.2 96 CO2-measurement range 25 Performance 65 GMM112 Carbon Dioxide Module for HVAC Applications Technical data 6 www.vaisala.com 30 60 which is based on an assumed background CO2 levels. In buildings with around-the-clock occupancy (e.g. hospitals, work-places, residential buildings, retirement homes), the assumed background CO2 level reference is simply not applicable. The true internal reference measurement of Vaisala CARBOCAP® CO2 transmitters provides years of stable CO2 measurements. The GMM112 Carbon Dioxide Module is designed especially for DCV (Demand Controlled Ventilation) applications with three optional CO2 measurement ranges of 0…2000 ppm, 0…5000 ppm and 0…10000 ppm. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210567EN-D ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 113 www.vaisala.com GMM20W Carbon Dioxide Module for OEM Applications Features/Benefits ▪ Incorporates the silicon based Vaisala CARBOCAP® Sensor ▪ Stable in terms of time and temperature ▪ Dust, water vapor or most chemicals do not affect the measurement accuracy of the sensor ▪ Small size enables easy integration into various systems Technical data Performance Dimensions CARBON DIOXIDE MEASUREMENT Dimensions in mm Measurement range 0 ... 2000 ppm (nominal; can be calibrated for other ranges: 0 ... 5000 ppm, 0 ... 10,000 ppm, 0 ... 20,000 ppm) Accuracy (including repeatability, ± (2 % of range + 2% non-linearity and calibration uncertainty) of reading) Long-term stability <±5 % of range / 5 years Response time (63%) 1 minute Warm-up time minute, 15 minutes full specifications Weight 45 g Inputs and outputs Outputs Resolution of analog outputs current output voltage output Operating voltage Power consumption 0 ... 20 or 4 ... 20 mA and 0 ... 10 V 8 bits max. 500 ohm min. 1 kohm nominal 24 VAC/DC (18 ... 30 VDC) <2.5 W Operating environment The Vaisala CARBOCAP® Carbon Dioxide Module GMM20W is designed for OEM applications in benign environments. Temperature Humidity Electromagnetic compatibility -5 ... +45 °C (+23 ... +113 °F) 0 ... 85 %RH, non-condensing EN61326-1, Generic Environment CARBOCAP® is a registered trademark of Vaisala. Accessories and options Display and relay option Relay output option Calibration software kit (disk and serial COM adapter) Analog temperature module* (not available when display option is added) For more information, visit www.vaisala.com or contact us at [email protected] 114 GMI21 GMR20 19222GM GMA20T Ref. B210939EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 115 www.vaisala.com GML20 and GML20T LonWorks® Options for GMD/W20 Series Technical data Features t -PO8PSLT® interoperable t 5XJTUFEQBJSGSFFUPQPMPHZOFUXPSLUZQF51'5BULCQT t "EEJUJPOBMUXPXJSFTOFFEFEGPSQPXFSJOHUIFUSBOTNJUUFSDBO thus be connected to both powered and non-powered networks t 4FSWJDFCVUUPOBOETFSWJDF-&%GPSTJNQMFJOTUBMMBUJPOBOE configuration t &YUFSOBMJOUFSGBDFYJG GJMFBWBJMBCMFPOSFRVFTU(.- part no. 19412GM, GML20T part no. 19748GM) t 5FNQFSBUVSF(.-5POMZ .FBTVSFNFOUBDDVSBDZ 0.5 °C (0.9 °F) Measurement range 0 ... +45 °C (+32 ... 113 °F) Warm-up time 30 min. Network Variables for CO2 (BOTH MODELS GML20 AND GML20T) GML20 (left) and GML20T modules enable digital communication between the Vaisala CARBOCAP® Carbon Dioxide Transmitter Series GM20 and a LonWorks® network. GML20T module connects a Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW21 to a LonWorks® network. Significant savings Vaisala's GML20 and GML20T are interface modules for distributing signals from Vaisala CARBOCAP® Carbon Dioxide Transmitter Series GM20 digitally to a LonWorks® network over a twisted pair. Features/Benefits ▪ Enables digital communication between Vaisala CARBOCAP® ▪ Carbon Dioxide Transmitter Series GM20 and LonWorks® ▪ ▪ ▪ GML20 for CO2 signal 116 GML20T for CO2 + T signal Savings in cabling, installation and maintenance costs The GML20 Module distributes CO2 signals; the GML20T Module distributes both CO2 and temperature signals. The GML20T Module can be used only with the Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW21. The use of these modules and Vaisala CARBOCAP® Carbon Dioxide Transmitter Series GM20 with a LonWorks® networked control system contributes to considerable savings in cabling, installation and maintenance costs. Intelligent LonTalk® protocol In a LonWorks® network, devices called nodes communicate with each other using the LonTalk ® protocol. Every node consists of a Neuron® chip and a transceiver. The Neuron® chip is a microprocessor which contains an application program and LonTalk ® protocol. The transceiver adapts the Neuron® chip into the hardware environment used. The nodes communicate with each other, sending messages containing the value of the desired variables. With Vaisala modules, these variables are CO2 (GML20) or CO2 and temperature (GML20T). Some network variables are so-called configuration variables, which are used to define the behavior of the node. With the GML20 and GML20T, they are used to designate how much the temperature and/or carbon dioxide level must change before a measured value is sent again. nviRequest: to request modes for objects within this node nvoStatus: to report status of objects on this node nvoCO2ppm: this output variable reports the CO2 level detected by the sensor nciMaxSendtime: indicates the maximum period of time that expires before the sensor object automatically updates all its output variables (default value: 300 seconds) nciMinSendtime: indicates the minimum period between output network variable transitions (default value: 5 seconds) nciCO2MinDelta: indicates the minimum CO2 level change required to update the output network variables (default value: 10 ppm) Networks Variables for Temperature (GML20T MODEL ONLY) nvoHVACtemp: this output variable reports the temperature detected by the sensor nciMaxStime_temp: indicates the maximum period of time that expires before the sensor object automatically updates all its output variables (default value: 300 seconds) nciMinStime_temp: indicates the minimum period between output network variable transitions (default value: 5 seconds) nciMinDelta_temp: indicates the minimum temperature change required to update the output network variables (default value: 0.3 °C) nciTmpOffset: indicates the temperature offset level (default value: -0.8 °C) LonWorks® is a registered trademark of Echelon Corporation. For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210943EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 117 Oxygen www.vaisala.com OMT355 Oxygen Transmitter for Industrial Process Measurements Low maintenance A stainless steel mesh filter and an optional porous PTFE filter protect the OMT355 probe optics from dust and dirt. An intelligent measurement algorithm further minimizes contamination effects and provides a maintenance alert well before the measurement performance is affected. gases injected through an optional calibration gas connector. The calibration interval of the OMT355 is 12 months. User friendly interfaces For calibration and configuration, the OMT355 features both software and keypad user interfaces and an LCD display. Long calibration interval TDL Technology Calibration or field checking of the instrument can be done either with ambient air or with zero/span The Tunable Diode Laser (TDL) technology used in the SPECTRACAP® sensor is one of the most powerful technologies in gas measurement on the market today. The technology is based on measuring the attenuation of a beam of laser light in the sample gas. For oxygen sensing the laser is tuned to a wavelength which is characteristic and unique for the oxygen molecule. Therefore, the measured attenuation is an extremely selective measure for the amount of oxygen on the path of the laser beam. OMT355 with the sampling cell. Technical data The Vaisala SPECTRACAP® Oxygen Transmitter. Features/Benefits ▪ Minimizes need for sample conditioning equipment ▪ In-situ probe or sampling cell options ▪ ▪ Tolerates aggressive chemicals ▪ ▪ Low maintenance ▪ Heated optical surfaces to prevent condensation ▪ Typical applications: Tolerates excessive amounts of moisture even in liquid form Diagnostic output for preventive maintenance đŏ #/ŏ#!*!.0%+* đŏ #/ŏ(*'!0%*# đŏ "!.)!*00%+* đŏ +),+/0%*#ŏ,.+!//ŏ monitoring 118 The Vaisala SPECTRACAP® Oxygen Transmitter OMT355 is ideal for oxygen monitoring in moist and aggressive process gases. Typical applications include gas generation, inert gas blanketing, fermentation and composting process monitoring. Laser based measurement The Vaisala SPECTRACAP® Oxygen Transmitter OMT355 is ideal for oxygen monitoring in moist and aggressive process gases.The OMT355 incorporates a compact tunable diode laser (TDL) gas spectrometer built in the measurement probe. This optical measurement technology is well known for unmatched stability and robustness. The SPECTRACAP® sensor offers TDL technology in a compact probe suitable for field use. Direct installation In many applications, the OMT355 can be flange-mounted directly into a process. No sampling or sample conditioning equipment is needed. This feature provides real time measurement data without sampling or sample switching delays. Sampling cell installation An optional sampling cell is available for processes with high temperatures, elevated pressures or extremely difficult mechanical conditions. Due to the robustness of the SPECTRACAP® sensor and its low sensitivity to gas flow and pressure variations, the sampling system can be very simple and it can be installed near the sampling point. Performance Operating Environment Measurement range 0 ... 100 % O2 Accuracy ±0.2 % O2 (including noise, linearity, and repeatability) Temperature dependence over T range ±2 % of reading Stability ±1 % of reading/yr Zero drift ±0.1 % O2/yr Response time of measurement 3s Diffusion limited response in still air T63/T90 without filters 10 s / 20 s with stainless steel mesh filter 10 s / 25 s with stainless steel mesh and PTFE filters 30 s / 70 s Pressure dependence without pressure compensation 0.8 ... 1.2 bar -2 % of reading 1.2 ... 1.4 bar -5 % of reading Accuracy of pressure compensation ±0.25 % of reading Background gas effects for CO2 and H2O, uncompensated <1 % of reading for <6 vol-% CO2 <1 % of reading for gas dewpoint < 30 °C Accuracy of background gas compensation ±0.5 % of reading 0 ... 50 vol-% CO2 0 ... 300 g/m3 H2O (Td = 80 °C) ±1 % of reading Operating temperature range for probe (in-line installation) -20 ... +80 °C for electronics (housing) -40 ... +60 °C for transmitter (ambient gas measurement) -20 ... +60 °C Storage temperature range -55 ... +80 °C Operating pressure range 0.8 ... 1.4 bar Maximum pressure range for probe up to 10 bar Compliance IEC(EN)-61326 Electrical equipment for measurement, control and laboratory use. EMC requirements EN50104 Electrical apparatus for the detection and measurement of oxygen. Performance requirements and test methods. EN50271 Electrical Apparatus for the Detection and Measurement of Combustible Gases, Toxic Gases or Oxygen Laser safety Class 1 laser product Inputs and Outputs Power supply input range Power consumption maximum typical Analog output maximum load Serial output (2-wire, non-isolated) Alarm/control relay 11 ... 36 VDC 6W 3W 0/4 ... 20 mA, sourcing 500 Ω RS-485 30 VAC/60 VDC 119 Technical data Mechanics Dimensions Housing material G-AlSi10 Mg (DIN 1725) Probe material AISI 316 Housing classification IP66 Dimensions 306 mm x 184 mm x 74 mm Weight 2.2 kg Mounting flange diameter 97 mm Can be fitted to standard flanges. Minimum sizes: DIN (2527B) DN50 and ANSI (150) 2.5" Cable bushing Cable gland M20 x 1.5 Stainless steel mesh filter openings ø 310 μm Wetted materials AISI 316, EPDM or Kalrez® (optional), PTFE (optional), SiN, MgF2 Dimensions in mm 306 mm x 184 mm x 74 mm Options and accessories Hydrophobic PTFE filter, pore size 8 μm with EPDM O-rings with Kalrez® O-rings 1/2" NPT conduit fitting M12 male 8-pin connector for user cable Serial interface cable for PC USB-RJ45 Serial interface cable Sample cell with wall mounting bracket with EPDM O-rings with Kalrez® O-rings 217055 217056 217197 214806SP 19446ZZ 219685 217052 216619 For complete specifications, refer to the User’s Guide. SPECTRACAP® is a registered trademark of Vaisala. Humidity and CO2 Measurement for Critical Environments For over 70 years Vaisala has provided RELIABLE measurements, helping you meet SPECIFICATIONS and allowing you to focus on your business. Our products are supported by our local experts, so you can have CONFIDENCE when it MATTERS. Take a look at useful knowledge items at www.vaisala.com/lifescience For more information, visit www.vaisala.com or contact us at [email protected] 120 Ref. B210623EN-C ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com 121 www.vaisala.com OMT364 Oxygen Transmitter for Hazardous Areas The Vaisala SPECTRACAP® Oxygen Transmitter OMT364 for hazardous areas. Features/Benefits ▪ Minimizes need for sample conditioning equipment ▪ ▪ ▪ In-situ probe or sampling cell ▪ ▪ ▪ Low maintenance ▪ Example applications: fermentation, composting process monitoring, inerting processes and flare gas recovery Tolerates aggressive chemicals Tolerates excessive amounts of moisture even in liquid form Calibration interval 12 months +"03.!ŏ* ŏ'!5, ŏ1/!.ŏ interfaces and an LCD display The Vaisala SPECTRACAP® Oxygen Transmitter OMT364 is designed for oxygen monitoring in moist and aggressive process gases. Laser based measurement The OMT364 incorporates a compact tunable diode laser (TDL) gas spectrometer built in the measurement probe. This optical measurement technology is well known for unmatched stability and robustness. The patented SPECTRACAP® sensor offers uniquely TDL technology in a compact probe suitable for field use. FM Approved OMT364 for Hazardous Areas The non-incendive OMT364 transmitter is permitted for use in Class I, Division 2 of the NEC® 500 area classification according to FM Approvals SM . The probe of the 122 instrument can be installed in areas that are classified as Class I, Division 1 or 2. Direct installation In many applications, the OMT364 can be flange-mounted directly into a process. No sampling or sample conditioning equipment is needed. This feature provides real time measurement data without sampling or sample switching delays. Sampling cell installation An optional sampling cell is available for processes with high temperatures, elevated pressures or extremely difficult mechanical conditions. Due to the robustness of the SPECTRACAP® sensor and its low sensitivity to gas flow and pressure variations, the sampling system is simple and it can be installed near the sampling point. Technical data Performance Classification Measurement range 0 ... 100 % O2 Accuracy (including noise, linearity and repeatability) ±0.2 % O2 Temperature range over T range ±2 % of reading Stability ±1 % of reading/yr Zero drift ±0.1 % O2/yr Response time of measurement 3s Diffusion limited response in still air T63/T90 without filters 10 s / 20 s with stainless steel mesh filter 10 s / 25 s with stainless steel mesh filter and PTFE filters 30 s / 70 s Pressure dependence without pressure compensation 0.8 ... 1.2 bar -2 % of reading 1.2 ... 1.4 bar -5 % of reading Accuracy of pressure compensation ±0.25 % of reading Background gas effects for CO2 and H2O uncompensated < 1% of reading for <6 vol -% CO2 < 1% of reading for gas dew point < 30 ˚C Accuracy of background gas compensation ±-0.5 % of reading 0 ... 50 vol-% CO2 0 ... 300 g/m3 H2O (Td=80 ˚C) ±1 % of reading OMT364 CLASSIFICATIONS FOR THE TRANSMITTER Operating environment Operating temperature range for probe (in-line installation) -20 ... +80 ˚C -20 ... +60 ˚C electronics (housing) (Kalrez® seals) transmitter (ambient gas measurement) -20 ... +60 ˚C Storage temperature range -55 ... +80 ˚C Operating pressure range 0.8 ... 1.4 bar Maximum pressure range for probe up to 10 bar Compliance IEC(EN)-61326 Electrical equipment for measurement, control and laboratory use. EMC requirements. Laser safety Class 1 laser product For more information, visit www.vaisala.com or contact us at [email protected] USA and Canada FM, Non-incendive for Class I, Division 2, Groups A, B, C, and D. Ta = -20 ˚C to +60 ˚C OMT364 CLASSIFICATIONS FOR THE PROBE USA and Canada FM, Suitable for Class I, Division 1, Groups A, B, C, and D. Ta = -20 ˚C to +80 ˚C Inputs and outputs Power supply input range Power consumption maximum typical Analog output maximum load Serial output (2-wire, non-isolated) Alarm/control relay 11 ... 36 VDC 6W 3W 0/4 ... 20 mA sourcing 500 Ω RS-485 30 VAC/60 VDC Mechanics Housing material Probe material Housing classification Weight, transmitter and probe Weight, sample cell Mounting flance diameter Cable bushing Stainless steel mesh filter Wetted materials AISI 316, Kalrez®, PTFE (optional), SiN, MgF2 G-AlSI10 Mg (DIN 1725) AISI 316 IP66 2.2 kg 2.6 kg 97 mm Cable gland M20 x 1.5 openings ø 310 μm Options and accessories Hydrophobic PTFE filter, pore size 8 μm with Kalrez® O-rings 1/2” NPT conduit fitting Sample cell with wall-mounting bracket gas fittings for O.D. 6 mm tube volume 260 m3 T63 response time with 1 l/min sample flow and mesh filter, 18 s with Kalrez® O-rings 217056 217917 216619 Ref. B210823EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 123 Barometric Pressure www.vaisala.com PTU300 Models PTU300 Combined Pressure, Humidity and Temperature Transmitter for demanding applications Dimensions in mm (inches) 120 (4.72) 12 (0.47) allowing users to easily monitor operational data, measurement trends and 1-year measurement history. The optional data logger with real-time clock makes it possible to generate over four years of measured history, and zoom in on any desired time or time frame. The battery backup of the real-time clock guarantees a reliable logging of measured data. Dimensions PTU301 for wall mounting The display alarm allows tracking of any measured parameter, with a freely configurable low and high limit. Dimensions Dimensions in mm (inches) 183 (7.20) Barometric pressure, humidity and temperature measurement in one transmitter ▪ Available with two barometric pressure sensors – added reliability ▪ RS-232C serial interface with NMEA protocol for GPS use ▪ Optional display, RS-485, analog output, and relay ▪ ▪ ▪ Optional power supply module ▪ Applications include environmental monitoring in calibration laboratories, GPS meteorology: estimating precipitable water vapor in the atmosphere; weather stations NIST traceable calibration HMT330MIK Installation kit for outdoor use The Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300 measures barometric pressure in two accuracy classes, humidity, and temperature. You can choose which probe best suits your needs: PTU301 for laboratories, PTU303 for outdoor use, the warmed PTU307 probe for demanding meteorology, and PTU30T for pressure and temperature only. Vaisala proven sensor technology The PTU300 transmitter uses sensors known for their high accuracy and excellent long-term stability: the Vaisala BAROCAP® is used for pressure measurement and the Vaisala HUMICAP® for humidity measurement. The temperature sensor is a platinum RTD sensor. Graphical trend display 124 The PTU300 series features a large numerical and graphical display, PTU301 short cable probe A USB-RJ45 cable makes it easy to connect the service port of the PTU300 to a PC. 42 (1.65) Flexible calibration A quick, one-point field calibration for humidity can easily be done using the Vaisala Hand-Held Humidity Meter HM70. Dimensions Dimensions in mm (inches) Serial communication The PTU300 comes with a standard RS-232 serial interface. The output format is compatible with major GPS receivers and NMEA coded messages. RS-485 is available as an option. M9x1 ▪ One transmitter, three measurements 106 (4.17) Features/Benefits The recorded measurement data can be viewed on the display or transferred to a PC with Microsoft Windows® software. The transmitter can also be connected to a network with an optional (W)LAN interface, which enables a (wireless) Ethernet connection. Ø 12 (0.47) The Vaisala PTU300 Combined Pressure, Humidity and Temperature Transmitter is a versatile, multi-purpose instrument. 116 (4.57) Data collection and (wireless) transfer to PC 37.5 (1.48) PTU303 for outdoor use 78.5 (3.09) 98.5 (3.88) Outdoor installation kit The optional HMT330MIK Installation Kit is available for outdoor installation. It provides reliable measurements for meteorological purposes. 125 PTU300 Models Technical data Dimensions Performance Dimensions in mm (inches) BAROMETRIC PRESSURE 79.5 (3.13) PTU307 warmed probe for demanding meteorological installations Ø 6 (0.24) Ø 3.2 (0.13) 99.5 (3.92) 130 (5.12) Dimensions Ø 6 (0.24) Ø 3.2 (0.13) Dimensions in mm (inches) 130 (5.12) CLASS A CLASS B Linearity ±0.05 hPa ±0.10 hPa ±0.20 hPa Hysteresis* ±0.03 hPa ±0.03 hPa ±0.08 hPa Repeatability* ±0.03 hPa ±0.03 hPa ±0.08 hPa Calibration ±0.07 hPa ±0.15 hPa ±0.20 hPa uncertainty** Accuracy at +20 °C*** ±0.10 hPa ±0.20 hPa ±0.30 hPa Temperature ±0.1 hPa ±0.1 hPa ±0.3 hPa dependence**** ±0.15 hPa ±0.25 hPa ±0.45 hPa Total accuracy (-40 ... +60 °C/ -40 ... +140 °F) Long-term stability/year ±0.1 hPa ±0.1 hPa ±0.2 hPa Response time (100 % response) one sensor 2 st 1 st 1 st Pressure units hPa, mbar, kPa, Pa, inHg, mmH20, mmHg, torr, psia 37.5 (1.48) PTU30T for pressure and temperature only measurement 500 ... 1100 hPa, 50 ... 1100 hPa 500 ... 1100 hPa 500 ... 1100 hPa 50 ... 1100 hPa M9x1 Ø 12 (0.47) Pressure range Accuracy * Defined as ±2 standard deviation limits of endpoint non-linearity, hysteresis error or repeatability error and calibration. ** Defined as ±2 standard deviation limits of accuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of endpoint non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. ACCURACY OVER TEMPERATURE RANGE Δ °C 0.5 0.4 0.3 0.2 0.1 °C 0 -0.1 -0.2 -0.3 -0.4 -0.5 -40 -20 0 20 Temperature sensor 40 60 PT100 RTD 1/3 Class B IEC 751 RELATIVE HUMIDITY Measurement range Accuracy (including non-linearity, hysteresis, and repeatability at +15 ... +25 °C 0 ... 100 %RH ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) at -20 ... +40 °C ±(1.0 + 0.008 x reading) %RH at -40 ... +60 °C ±(1.5 + 0.015 x reading) %RH Factory calibration uncertainty (+20 °C ) ± 0.6 %RH (0 ... 40 %RH) (Defined as ±2 standard deviation ± 1.0 %RH (40 ... 97 %RH) limits. Small variations possible, see also calibration certificate.) Sensor for typical applications Vaisala HUMICAP® 180 or 180R* for applications with chemical purge/warmed probe Vaisala HUMICAP® 180C or 180RC* Response time (90 %) at +20 °C (+68 °F) in still air with grid filter 8 s / 17 s* with grid + steel netting filter 20 s / 50 s* with sintered filter 40 s / 60 s* * with HUMICAP® 180R or 180RC sensor TEMPERATURE Measurement range, all probes Accuracy at +20 °C (+68 °F) Temperature units 126 The display also shows the WMO pressure trend ΔP 3h and tendency of 0 ... 9. -40 ... +60 °C (-40 ... +140 °F) ± 0.2 °C (± 0.4 °F) °C, °F Operating Environment Operating temperature with display Humidity range Electromagnetic compatibility -40 ... +60 °C (-40 ... +140 °F) 0 ... +60 °C (+32 ... +140 °F) non-condensing EN61326-1:1997 + Am1:1998 +Am2:2001; Industrial Environment Inputs and outputs Operating voltage 10 ... 35 VDC, 24 VAC with optional power supply module 100 ... 240 VAC, 50/60 Hz Power consumption at +20 °C (Uin 24 VDC) RS-232 max. 28 mA Uout 3 x 0 ... 1 V/0 ... 5 V/0 ... 10 V max. 33 mA max. 63 mA Iout 3 x 0 ... 20 mA display and backlight +20 mA during chemical purge max. +110 mA during probe heating +120 mA Settling time at power-up (one sensor) class A 4s class B 3s External loads current outputs RL < 500 ohm 0 ... 1 V output RL > 2 kohm 0 ... 5 V and 0 ... 10 V outputs RL > 10 kohm 127 Mechanics Cable bushing M20 x 1.5 for cable diameter 8 ... 11 mm/0.31 ... 0.43" Conduit fitting 1/2" NPT User cable connector (optional) M12 series 8-pin (male) option 1 female plug with 5 m (16.4 ft) black cable option 2 female plug with screw terminals Probe cable diameter PTU303 6.0 mm other probes 5.5 mm Housing material G-AlSi 10 Mg (DIN 1725) Housing classification IP 65 (NEMA 4) Weight depending on selected probe 1.5 ... 2.0 Kg Accessories PC software and cable USB-RJ45 Serial Connection Cable Connection cable for HM70 Wall mounting plate (plastic) Pole installation kit Rain shield DIN rail installation set Duct installation kit, PTU303/307 Cable gland and AGRO, PTU303/307 Solar radiation shield, PTU303/307/30T Meteorological installation kit Duct installation kit (T probe) 215005 219685 211339 214829 215108 215109 211477 210697 HMP247CG DTR502B HMT330MIK 215003 Dimensions Dimensions in mm (inches) 96 (3.78) Ø 7 (0.28) 116 (4.57) 183 (7.20) 169 (6.65) Reliable and accurate HVAC solutions 77 (3.03) 71 (2.80) Recommended wire size 0.5 mm2 (AWG 20) stranded wires Digital outputs RS-232, RS-485 (optional) Service connection RS-232, USB Relay outputs (optional) 0.5 A, 250 VAC Ethernet interface (optional) Supported standards 10/100Base-T Connector RJ45 Protocols Telnet Software support Vaisala MI70 link WLAN interface (optional) Supported standards 802.11b Antenna connector type RP-SMA Protocols Telnet Security WEP 64/128,WPA Software support Vaisala MI70 link Authentication / Encryption (WLAN) Open / no encryption Open / WEP WPA Pre shared key / TKIP WPA Pre shared key / CCMP (a.k.a. WPA2) Optional data logger with real-time clock Logged parameters max. three with trend/min/max values Logging interval 10 sec (fixed) Max. logging period 4 years 5 months Logged points 13.7 million points per parameter Battery lifetime min. 5 years Display LCD with backlight, graphic trend display of any parameter Menu languages English, Finnish, French, German, Japanese, Chinese, Spanish, Swedish, Russian Analog outputs (optional) current output 0 ... 20 mA, 4 ... 20 mA voltage output 0 ... 1 V, 0 ... 5 V, 0 ... 10 V Humidity and temperature accuracy at +20 °C ±0.05% full scale temperature dependence ±0.005%/°C full scale Pressure 500 ... 1100 hPa 50 ... 1100 hPa accuracy at +20 °C ±0.30 hPa ±0.40 hPa accuracy at -40 ... +60 °C ±0.60 hPa ±0.75 hPa BAROCAP® and HUMICAP® are registered trademarks of Vaisala. / HUMIDITY & CO2 TYPE APPROVED PRODUCT CERTIFICATE NO.: A-11440 For more information, visit www.vaisala.com or contact us at [email protected] 128 Ref. B210954EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. www.vaisala.com/hvac 129 www.vaisala.com PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users against one another and provides information on whether these are within the set internal difference criteria. This unique feature provides redundancy in pressure measurement. Vaisala BAROCAP® Digital Barometer PTB330 with a new trend display. Vaisala BAROCAP® Digital Barometer PTB330 is a new generation barometer, designed for a wide range of high-end atmospheric pressure measurement. The pressure measurement of the PTB330 is based on the Vaisala in-house, silicon Features/Benefits capacitive, absolute pressure sensor - the Vaisala BAROCAP® Sensor. It provides high measurement accuracy and excellent long-term stability. Highly accurate The PTB330 series is highly accurate. The Class A barometers for the most demanding applications are fine-tuned and calibrated against a high-precision pressure calibrator. Class B barometers are adjusted and calibrated using electronic working standard. All the PTB330 barometers come with a NIST traceable, factory calibration certificate. ▪ ▪ ▪ ▪ Vaisala BAROCAP® sensor ▪ Graphical trend display with 1-year history data Reliability through redundancy ▪ Height and altitude corrected pressure (QFE, QNH) ▪ For professional meteorology and aviation, laboratories, demanding industrial applications According to customers’ choice, the PTB330 can incorporate one, two or three BAROCAP® sensors. When two or three sensors are used, the barometer continuously compares the readings of the pressure sensors Accurate measurement Excellent long-term stability Added reliability through redundancy 130 Technical data Performance Inputs and outputs BAROMETRIC PRESSURE RANGE 500 ... 1100 hPa Linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C (+68 °F) *** Class B ±0.20 hPa ±0.08 hPa ±0.08 hPa ±0.15 hPa ±0.20 hPa Linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C *** QNH and QFE TEMPERATURE DEPENDENCE**** Graphical display The PTB330 features a multi-lingual, graphical display allowing users to monitor measurement trends. The graph is updated automatically while measuring and it provides a one-year measurement history. In addition to instant pressure, the PTB330 also provides the WMO pressure trend and tendency codes. Class B ±0.10 hPa ±0.03 hPa ±0.03 hPa ±0.15 hPa ±0.20 hPa BAROMETRIC PRESSURE RANGE 50 ... 1100 hPa Thus, users also get a stable and reliable pressure reading at all times as well as a pre-indication of when to service or recalibrate the barometer. The PTB330 can be set to compensate for QNH and QFE pressure used especially in aviation. The QNH represents the pressure reduced to sea level, based on the altitude and temperature of the observation site. The QFE represents the height corrected pressure of small differences in altitude, for example, the air pressure at the airfield elevation. Class A ±0.05 hPa ±0.03 hPa ±0.03 hPa ±0.07 hPa ±0.10 hPa 500 ... 1100 hPa 50 ... 1100 hPa ±0.1 hPa ±0.3 hPa TOTAL ACCURACY -40 ... +60 °C (-40 ... +140 °F) Class A ±0.15 hPa 500 ... 1100 hPa 50 ... 1100 hPa Class B ±0.25 hPa ±0.45 hPa LONG-TERM STABILITY 500 ... 1100 hPa ±0.1 hPa/year 50 ... 1100 hPa ±0.1 hPa/year * Defined as ±2 standard deviation limits of endpoint non-linearity, hysteresis or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of endpoint non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. Supply voltage 10 ... 35 VDC Supply voltage sensitivity negligible Typical power consumption at +20 °C (Uin 24 VDC, one pressure sensor) RS-232 25 mA RS-485 40 mA 25 mA Uout 40 mA Iout display and backlight +20 mA Serial I/O RS232C, RS485/422 Pressure units hPa, mbar, kPa, Pa inHg, mmH20, mmHg, torr, psia Class A Class B Resolution 0.01 hPa 0.1 hPa Settling time at power-up (one sensor) 4s 3s Response time (one sensor) 2s 1s Acceleration sensitivity negligible Pressure connector M5 (10-32) internal thread Pressure fitting barbed fitting for 1/8” I.D. tubing or quick connector with shutoff valve for 1/8” hose Maximum pressure limit 5000 hPa abs. Compliance EMC standard EN61326-1:1997 + Am1:1998 + Am2:2001: Industrial Environment Mechanics Housing material Housing classification Weight G AlSi10 Mg (DIN 1725) IP66 1 - 1.5 kg Analog output (optional) Current output Voltage output Accuracy at pressure range at +20 °C at -40 ... +60 °C 0 ... 20 mA, 4 ... 20 mA 0 ... 1 V, 0 ... 5 V, 0 ... 10 V 500 ... 1100 hPa 50 ... 1100 hPa ±0.30 hPa ±0.40 hPa ±0.60 hPa ±0.75 hPa Operating environment Pressure range Temperature range operating with local display 500 ... 1100 hPa, 50 ... 1100 hPa -40 ... +60 °C (-40 ... +140 °F) 0 ... +60 °C (+32 ... +140 °F) Applications Data transfer software The PTB330 can be used successfully for aviation, professional meteorology, and for demanding industrial pressure measurement applications such as accurate laser interferometric measurement and exhaust gas analysis in engine test benches. MI70 Link Interface Software Requirement: Microsoft® Windows OS Microsoft® Excel For more information, visit www.vaisala.com or contact us at [email protected] Accessories Serial interface cable USB-RJ45 serial connection cable Software interface kit Wall mounting kit Outdoor installation kit (weather shield) Installation kit for pole or pipeline Power supply module Temperature compensated analog output module Isolated RS-485 module 19446ZZ 219685 215005 214829 215109 215108 POWER-1 AOUT-1T RS485-1 Ref. B210708EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 131 www.vaisala.com Take the lab to the field Vaisala Barometric Pressure Transfer Standard PTB330TS The PTB330 Digital Barometer The HMP155 probe The MI70 hand-held indicator displaying the prevailing pressure in hPa includes a PTB330 digital PTB330 Digital barometer barometer, hand-held MI70 Vaisala BAROCAP® Digital Barometer PTB330 is a new generation barometer designed for a wide range of high-end atmospheric pressure measurement. The pressure measurement of the PTB330 is based on the Vaisala in-house, silicon capacitive, absolute pressure sensor – the Vaisala BAROCAP® Sensor. It provides high measurement accuracy and excellent long-term stability. against one another and provides information on whether these are within the set internal difference criteria. This unique feature provides redundancy in pressure measurement. Thus, users get a stable and reliable pressure reading at all times as well as a pre-indication of when to service or re-calibrate the barometer. probe for the HMP155 is ideal for measurement in environments with rapidly changing temperatures. Operational PTB330TS unit indicator, optional HMP155 humidity and temperature probe, optional MI70 Link PC software, a user’s guide and a weatherproof transfer case equipped with a shoulder strap. PTB330TS transport case High accuracy Barometric Pressure Transfer Standard PTB330TS makes field inspection accurate and easy. It combines a PTB330 digital barometer with a hand-held MI70 indicator within a portable unit functioning as a transfer standard. The optional HMP155 probe is available for accurate humidity and temperature measurement. The PTB330TS is suitable for various reference measurements in industrial and meteorological areas. The PTB330TS comes in a durable and weatherproof transport case that can be easily carried and shipped. The components are placed in a proofing foam interior, with accessories and user’s guide placed in the lid organizer. The case includes a separate inner tabletop case in which the barometer is mounted. Shoulder strap is included for convenience. Battery duration is up to 11 hours of continuous use and up to 30 days in data logging use. Features / Benefits ▪ Portable, battery operated transfer standard with data logging capability ▪ Optional humidity and temperature measurents with HMP155 ▪ Data can be logged, and transferred to a PC via MI70Link software Barometric pressure with Vaisala BAROCAP® Digital Barometer PTB330 – Vaisala HUMICAP®180R sensor superior long-term stability ▪ SO/IEC 17025 Accredited calibration services available – New, fast temperature probe – Excellent long term stability ▪ – Chemical purge For professional meteorology, aviation, laboratories and demanding industrial applications – Accurate measurents – Added reliability through redundancy 132 ▪ ▪ Multilingual user interface, nine languages The PTB330 series features extremely high accuracy. Class A barometers for the most demanding applications are fine-adjusted and calibrated against a high-precision pressure calibrator. All the PTB330 barometers come with a NIST traceable, factory calibration certificate, also optional ISO/IEC 17025 accreditation calibration services are available. Reliability through redundancy According to customers’ choice, the PTB330 can incorporate one, two or three BAROCAP® sensors. When two or three sensors are used, the barometer continuously compares the readings of the pressure sensors Optional HMP155 Humidity and temperature probe The new Vaisala HUMICAP® Humidity and Temperature Probe HMP155 provides reliable humidity and temperature measurement. Long-term stability The HMP155 has a new generation Vaisala HUMICAP®180R sensor that has excellent stability and withstands harsh environments well. The probe structure is solid and the sensor is protected with a sintered teflon filter, which gives maximum protection against liquid water, dust, and dirt. Fast temperature measurement MI70 Hand-held indicator for spot-checking applications The Vaisala Measurement Indicator MI70 is a user-friendly indicator for demanding spot-checking measurements. It is ideal for field checking and calibration of Vaisala’s fixed instruments. Easy-to-use user interface and three-variable display The MI70 features a multilingual, menu-based user interface, and a clear graphical LCD display. Overall three measurement parameters can be displayed and logged into the meter’s memory at the same time. One or two probes or transmitters can be connected simultaneously. MI70 Link The optional MI70 Link Windows® software and the USB connection cable form a practical tool for transferring logged data and real time measurement data from the MI70 to a PC. What’s more, with its fast response time, the additional temperature For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210785EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 133 www.vaisala.com Vaisala Barometric Pressure Transfer Standard PTB330TS Technical data Available Parameters Technical data Pressure parameters Humidity and temperature parameters These specifications apply when MI70, PTB330 and HMP155 are used together in the PTB330TS product. For individual specifications, please refer to the product documentation and brochures of the PTB330 and HMP155. Inputs and outputs MI70 probe ports MI70 data interface General Operating temperature range Operating humidity range Maximum pressure limit Power supply PTB330TS is in conformity with the following EU directives: - EMC Directive (2004/108/EC) Complies with the EMC product family standard EN61326-1, Electrical equipment for measurement control and laboratory use - Basic immunity test requirements. - Low Voltage Directive (2006/95/EC) - ROHS Directive (2002/95/EC) Performance Barometric pressure (PTB330) Measurement range Linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C (+68 °F) *** Temperature dependence**** Total accuracy -40... +60 °C (-40...+140 °F) Long-term stability Settling time at power-up (one sensor) Response time (one sensor) Acceleration sensitivity 500 ... 1100 hPa ±0.05 hPa ±0.03 hPa ±0.03 hPa ±0.07 hPa ±0.10 hPa ±0.1 hPa ±0.15 hPa ±0.1 hPa/year 4s 2s negligible Defined as ±2 standard deviation limits of endpoint nonlinearity, hysteresis or repeatability error. 㻖㻖㻌 㻰㼑㼒㼕㼚㼑㼐㻌㼍㼟㻌㼼㻞㻌㼟㼠㼍㼚㼐㼍㼞㼐㻌㼐㼑㼢㼕㼍㼠㼕㼛㼚㻌㼘㼕㼙㼕㼠㼟㻌㼛㼒㻌㼕㼚㼍㼏㼏㼡㼞㼍㼏㼥㻌㼛㼒㻌㼠㼔㼑㻌㼣㼛㼞㼗㼕㼚㼓㻌㼟㼠㼍㼚㼐㼍㼞㼐㻌㼕㼚㼏㼘㼡㼐㼕㼚㼓㻌 㼠㼞㼍㼏㼑㼍㼎㼕㼘㼕㼠㼥㻌㼠㼛㻌㻺㻵㻿㼀㻚 㻖㻖㻖㻌 㻰㼑㼒㼕㼚㼑㼐㻌㼍㼟㻌㼠㼔㼑㻌㼞㼛㼛㼠㻌㼟㼡㼙㻌㼛㼒㻌㼠㼔㼑㻌㼟㼝㼡㼍㼞㼑㼟㻌㻔㻾㻿㻿㻕㻌㼛㼒㻌㼑㼚㼐㼜㼛㼕㼚㼠㻌㼚㼛㼚㻙㼘㼕㼚㼑㼍㼞㼕㼠㼥㻘㻌㻌㼔㼥㼟㼠㼑㼞㼑㼟㼕㼟㻌㼑㼞㼞㼛㼞㻘㻌 㼞㼑㼜㼑㼍㼠㼍㼎㼕㼘㼕㼠㼥㻌㼑㼞㼞㼛㼞㻌㼍㼚㼐㻌㼏㼍㼘㼕㼎㼞㼍㼠㼕㼛㼚㻌㼡㼚㼏㼑㼞㼠㼍㼕㼚㼠㼥㻌㼍㼠㻌㼞㼛㼛㼙㻌㼠㼑㼙㼜㼑㼞㼍㼠㼡㼞㼑㻚 㻖㻖㻖㻖㻌㻰㼑㼒㼕㼚㼑㼐㻌㼍㼟㻌㼼㻞㻌㼟㼠㼍㼚㼐㼍㼞㼐㻌㼐㼑㼢㼕㼍㼠㼕㼛㼚㻌㼘㼕㼙㼕㼠㼟㻌㼛㼒㻌㼠㼑㼙㼜㼑㼞㼍㼠㼡㼞㼑㻌㼐㼑㼜㼑㼚㼐㼑㼚㼏㼑㻌㼛㼢㼑㼞㻌㼠㼔㼑㻌㼛㼜㼑㼞㼍㼠㼕㼚㼓㻌 㼠㼑㼙㼜㼑㼞㼍㼠㼡㼞㼑㻌㼞㼍㼚㼓㼑㻚 134 2 RS-232 (accessible only with MI70 Link software) 10 ... 35 VDC (if not powered by MI70) RS-232C RJ45 (service port) Male 8-pin M12 (user port) RS-485 Male 8-pin M12 PTB330 supply voltage -10 ... +40 °C (+14 ... +104 )°F non-condensing 5000 hPa abs. Rechargeable NiMH battery pack with AC-adapter or 4xAA-size alkalines, type IEC LR6 Operation time (using rechargeable battery pack) Continuous use with PTB330 11 h typical at +20 °C (+68 °F) Datalogging use up to 30 days Menu languages English, Chinese, French, Spanish, German, Russian, Japanese, Swedish, Finnish Display LCD with backlight, graphic trend display of any parameter, character height up to 16 mm Data logging capacity 2700 points Alarm audible alarm function * Accessories P, P3h, HCP, QFE, QNH RH, T, Tdf, Td, x, Tw PTB330 data interface PTB330 serial I/O connectors HMP155 data interface HMP155 serial I/O connector Mechanics Housing material Housing classification Pressure connector Pressure fitting Measurement range Accuracy (incl. non-linearity, hysteresis and repeatability) at +15 ... +25 °C (+59 ... +77 °F) * Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate. Temperature (HMP155) Measurement range Accuracy -10 ... +20 °C G-AlSi 10 Mg (DIN 1725) IP65 M5 (10-32) internal thread barbed fitting for 1/8” I.D. tubing or quick connector with shutoff valve for 1/8” hose 0 ... 100 %RH ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) -10 ... +40 °C (-4 ... 104 °F) ±(1.0 + 0.008 x reading) %RH Factory calibration uncertainty (+20 °C /+68 °F) ±0.6 %RH (0 ... 40 %RH)* ±1.0 %RH (40 ... 97 %RH)* Humidity sensor HUMICAP180R HUMICAP180RC Response time at +20 °C in still air with a sintered PTFE filter 63 % 20 s 90 % 60 s -10 ... +40 °C (+14 ... +104 °F) ±(0.176 - 0.0028 x temperature) °C +20 ... +40 °C ±(0.07 + 0.0025 x temperature) °C Accuracy over temperature range (see graph overleaf) Temperature sensor Pt100 RTD 1/3 Class B IEC 751 Response time with additional temperature probe in 3 m/s air flow 63 % <20 s 90 % <35 s MI70 – PTB330 Spiral Cable USB-RJ45 serial connection cable Serial connection cable Barbed fitting 1/8” Quick Connector 1/8” Transport case with interior foams and tabletop casing for PTB330 Tabletop casing for PTB330 223235SP 219685 19446ZZ 19498SP 220186 224068SP 224064SP MI70 USB cable for MI70, includes MI70 Link software MI70 Link software MI70 connection cable to HMT330, MMT330, DMT340, HMT100, PTB330 MI70 battery pack variety of AC adapters available 219687 MI70LINK 211339 26755 HMP155 PTB330 Relative humidity (HMP155) PTB330 HMP155 Housing material Housing classification Additional T-probe cable length Cable material Sensor protection PC IP66 2m PUR Sintered PTFE MI70 MEASUREMENT INDICATOR Housing classification Housing material IP54 ABS/PC blend HMP155 – MI70 connection cable Protection set for HMP155 calibration buttons: protective cover, 2 O-rings and protective plug USB cable for HMP155 Sintered teflon filter + O-ring Humidity sensor Humidity Calibrator 221801 221318 221040 219452SP HUMICAP180R HMK15 TRANSPORT CASE Housing classification (when closed) Plastic parts Metal parts Interior foam material Weight with all instruments and typical accessories Exterior dimensions (LxWxH) IP67 TTX01®, PP+SEBS, POM stainless steel AISI303 PE and polyether 5.9 kg 405×330×165 mm (15.94×12.99×6.50) inch For more information, visit www.vaisala.com or contact us at [email protected] Accuracy of HMP155 temperature measurement over temperature range Ref. B210786EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 135 www.vaisala.com PTB210 Digital Barometer Technical data Operating range (1hPa=1mbar) General Pressure range (order specified) serial output t'BDUPSZTFUUJOH analog output Operating temperature range Humidity range 500 ... 1100 hPa 50 ... 1100 hPa 500 ... 1100 hPa 600 ... 1060 hPa 800 ... 1060 hPa 900 ... 1100 hPa -40 ... +60 °C (-40 ... +140 °F) non-condensing SERIAL OUTPUT Current consumption normal mode power down mode shutdown mode Shutdown Settling time at power up 4FSJBM*0GBDUPSZTFUUJOHt Accuracy SERIAL OUTPUT (units in hPa) Pressure range The PTB210 paired with the SPH10 Static Pressure Head. The Vaisala BAROCAP® Digital Barometer PTB210 is a reliable outdoor barometer that withstands harsh conditions. Non linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C (+68 °F)*** Temperature dependence**** Total accuracy*** -40 ... +60 °C (-40 ... +140 °F) Long term stability (hPa/year) 500 ... 1100 Class A Class B ± 0.10 ± 0.15 ± 0.05 ± 0.05 ± 0.05 ± 0.05 ± 0.07 ± 0.15 ± 0.15 ± 0.20 ± 0.20 ± 0.20 ± 0.25 ± 0.30 ± 0.10 ± 0.10 50 ... 1100 ± 0.20 ± 0.10 ± 0.10 ± 0.20 ± 0.35 ± 0.40 ± 0.50 ± 0.20 ANALOG OUTPUT For harsh environments ® The Vaisala BAROCAP Digital Barometer PTB210 is ideal for outdoor installations and harsh environments. The barometers are designed to operate in a wide temperature range, and the electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water. Features/Benefits ▪ 500 ... 1100 hPa or 50 ... 1100 hPa pressure ranges with serial output ▪ Different scalings between 500 ... 1100 hPa with analog output ▪ Electronics housing IP65 protected against sprayed water ▪ Accurate and stable measurement ▪ NIST traceable (certificate included) 136 The PTB210 barometers are ideal for use in applications such as weather stations, data buoys and ships, airports, and agrology. They are also an excellent solution for monitoring barometric pressure in industrial equipment such as laser interferometers and engine test benches. Several pressure ranges The PTB210 barometers are designed for various pressure ranges. They are available in two basic configurations: serial output for 500 ... 1100 hPa and 50 ... 1100 hPa and analog output with different scalings between 500 ... 1100 hPa. Accurate and stable measurement All the PTB210 barometers are digitally adjusted and calibrated by using electronic working standards. A higher accuracy barometer, that is fine-tuned and calibrated against a High Precision Pressure Calibrator, is available for the 500 ... 1100 hPa pressure range. In addition, the PTB210 integrates directly with Vaisala Static Pressure Head Series SPH10/20. This pairing offers accurate measurement in all wind conditions. Vaisala BAROCAP® technology The PTB210 barometers use the Vaisala BAROCAP® Sensor, a silicon capacitive absolute pressure sensor developed by Vaisala for barometric pressure applications. The Vaisala BAROCAP® Sensor provides excellent hysteresis and repeatability characteristics and outstanding temperature and long-term stability. All PTB210 barometers are delivered with a factory calibration certificate which is NIST traceable. Non linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C (+68 °F)*** Temperature dependence**** Total accuracy*** -40 ... +60 °C (-40 ... +140 °F) Long term stability ± 0.20 hPa ± 0.05 hPa ± 0.05 hPa ± 0.15 hPa ± 0.30 hPa ± 0.50 hPa ± 0.60 hPa ± 0.10 hPa/year * Defined as the ±2 standard deviation limits of end point non-linearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of end point non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. For more information, visit www.vaisala.com or contact us at [email protected] parity data bits stop bits Baud rate Response time Resolution N"t < 0.8 mA 0.2 mA ON/OFF 2s RS232C RS232C /TTL (optional) RS485, non isolated (optional) OPOFFWFOtPEE t t t Tt 0.01 hPa (1 measurement/s) 0.03 hPa (10 measurements/s) ANALOG OUTPUT Outputs Current consumption normal mode shutdown mode Shutdown Response time Resolution Measurement rate 0 ... 5 VDC, 0 ... 2.5 VDC (order specified) < 8 mA 0.2 mA ON/OFF 500 ms 300 μV 3 measurements/s ALL MODELS Supply voltage (reverse polarity protected) with RS232/TTL output 5 ... 28 VDC with RS485 or analog output 8 ... 18 VDC Max. pressure 5 000 hPa abs. Pressure connector M5 (10-32) internal thread Pressure fitting barbed fitting for 1/8" I.D. tubing Housing electronics IP65 (NEMA 4) sensor IP53 Housing material PC plastic Supply/output cable length 1, 2, 3, 5 or 10 m Instrument 110 g Cable 28 g/m Electromagnetic compatibility Complies with EMC standard EN61326-1, Generic Environment Ref. B210942EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 137 www.vaisala.com Technical data PTB110 Barometer for Industrial Use Operating range (1 hPa=1mbar) Accuracy Pressure ranges Linearity* ±0.25 hPa Hysteresis* ±0.03 hPa Repeatability* ±0.03 hPa Calibration uncertainty** ±0.15 hPa Accuracy at +20 °C*** ±0.3 hPa * Defined as ±2 standard deviation limits of end-point non-linearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of end-point non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. Features/Benefits PTB110 Accuracy and stability ▪ ▪ ▪ ▪ ▪ Vaisala BAROCAP® sensor The Vaisala BAROCAP® Barometer PTB110 is designed both for accurate barometric pressure measurements at a room temperature and for general environmental pressure monitoring over a wide temperature range. The excellent long-term stability of the barometer minimizes or even removes the need for field adjustment in many applications. ▪ Output voltage 0 ... 2.5 or 0 ... 5 VDC ▪ Current consumption less than 4 mA ▪ Mountable on a (35 mm wide) DIN rail ▪ NIST traceable (certificate included) 138 Several pressure ranges Accuracy ±0.3 hPa at +20 °C Long-term stability On/off control with external trigger Vaisala BAROCAP® technology The PTB110 barometer uses the Vaisala BAROCAP® Sensor, a silicon capacitive absolute pressure sensor developed by Vaisala for barometric pressure measurement applications. The sensor combines the outstanding elasticity characteristics and mechanical stability of single-crystal silicon with the proven capacitive detection principle. Applications The PTB110 is suitable for a variety of applications, such as environmental pressure monitoring, data buoys, laser interferometers, and in agriculture and hydrology. The compact PTB110 is especially ideal for data logger applications as it has low power consumption. Also an external On/Off control is available. This is practical when the supply of electricity is limited. For more information, visit www.vaisala.com or contact us at [email protected] TOTAL ACCURACY AT +15 ... +25 °C (+59 ... +77 °F) 0 ... +40 °C (+32 ... +104 °F) -20 ... +45 °C (-4 ... +113 °F) -40 ... +60 °C (-40 ... +140 °F) Long-term stability ±0.3 hPa ±0.6 hPa ±1.0 hPa ±1.5 hPa ±0.1 hPa/year Dimensions Dimensions in mm (inches) 2.69 68.40 0.14 3.50 1.11 28.1 0.62 15.82 3.54 90 The Vaisala BAROCAP® Barometer PTB110 offers outstanding long-term stability. 10 ... 30 VDC with TTL level trigger negligible less than 4 mA less than 1 μA 0 ... 2.5 VDC 0 ... 5 VDC Output frequency 500 ... 1100 Hz Resolution 0.1 hPa Load resistance minimum 10 kohm Load capacitance maximum 47 nF Settling time 1 s to reach full accuracy after power-up Response time 500 ms to reach full accuracy after a pressure step Acceleration sensitivity negligible Pressure connector M5 (10-32) internal thread Pressure fitting barbed fitting for 1/8" Minimum pressure limit 0 hPa abs Maximum pressure limit 2000 hPa abs Electrical connector removable connector for 5 wires (AWG 28 ... 16) Terminals Pin 1: external triggering Pin 2: signal ground Pin 3: supply ground Pin 4: supply voltage Pin 5: signal output Housing material, plastic cover ABS/PC blend Housing classification IP32 Metal mounting plate Al Weight 90 g Electromagnetic compatibility Complies with EMC standard EN 61326-1, Electrical equipment for measurement, control and laboratory use - EMC requirements - for use in industrial locations 0.16 4 Supply voltage Suppply voltage control Supply voltage sensitivity Current consumption in shutdown mode Output voltage 3.00 76.20 General 3.83 97.3 Temperature range Humidity range 500 ... 1100 hPa 600 ... 1100 hPa 800 ... 1100 hPa 800 ... 1060 hPa 600 ... 1060 hPa -40 ... +60 °C (-40 ... +140 °F) non-condensing 0.53 13.40 0.28 Ø 7.20 BAROCAP® is a registered trademark of Vaisala. Ref. B210681EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 139 www.vaisala.com SPH10/20 Static Pressure Heads for Minimizing Wind Induced Error Wind induced effects are one of the main sources of error when measuring barometric pressure. Variations due to strong and gusty wind can be overcome by using a static pressure head to ‘filter out’ the effect of dynamic pressure. The Vaisala Static Pressure Head Series SPH10/20 are designed to minimize the errors caused by wind. The wind tunnel tested structure is both horizontally and vertically symmetrical. This design ensures reliable barometric pressure measurements in all weather. Ideal for outdoor installations Vaisala’s static pressure heads are available in two models: the Vaisala Static Pressure Head SPH10 is a basic version, and the Vaisala Static Pressure Head SPH20 is a heated version for reliable operation in snowy and icy conditions. The warmed SPH20 contains a thermostat that switches on the warming power at temperatures, where the risk of icing may occur. Technical data General Operating temperature Weight SPH10 SPH20 Material Mounting Hose connection SPH10/20 static pressure heads are durable and weather resistant. The SPH10/20 protects against rain and condensed water, thus preventing capillary condensation of a water column in the pressure channel which results in pressure error. The drain holes in the lower plate allow rain and water to flow out. The static pressure heads have internal netting which prevents insects and debris from blocking the pressure channel. SPH20 -60 ... +80 °C (-76 ... +176 °F) 800 g 1360 g PC plastic, offshore aluminium with 2 bolts (M6 X 20 mm min) barbed fitting for 4 mm I.D. hose or Rp1/4 thread (parallel) Electrical connections Power supply M12 connector factory setting 12 V changed connection 24 V Thermostat switching temperature On Off Power consumption during heating +4 °C (±3 °C) +39.2 °F (±4.4 °F) +13 °C (±3 °C) +55.4 °F (±4.4 °F) 70 W Dimensions Dimensions in mm SPH10 Carefree maintenance The SPH10/20 static pressure heads are easy to install and disassemble, service and clean – even at the installation site. Vaisala BAROCAP® Digital Barometer PTB210 can be installed directly on top of the SPH10/20 static pressure heads. Other barometers can be connected to the heads with pressure tubing. SPH10 and SPH20 are a perfect pair for all Vaisala barometers. They ensure an accurate and reliable measurement in all weather conditions. The SPH10/20 is easy to install and connect. In the picture, a SPH10 is connected to a PTB210 barometer. SPH20 Composed of ultraviolet stabilized PC plastics and offshore aluminium, the Features/Benefits ▪ ▪ Minimizes wind induced error ▪ Wind tunnel tested structure Reliable barometric pressure measurement in all weather ▪ ▪ Easy-to-clean Easy-to-install For more information, visit www.vaisala.com or contact us at [email protected] 140 Ref. B210907EN-A ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 141 Wind www.vaisala.com Vaisala Weather Transmitter WXT520 Access to Real Time Weather Data Technical data Wind Air temperature SPEED range response time accuracy 0 ... 35 m/s 35 m/s ... 60 m/s output resolutions and units 0 ... 60 m/s 250 ms ±0.3 m/s or ±3%, whichever is greater ±5% 0.1 m/s, 0.1km/h, 0.1 mph, 0.1 knots 0 ... 360° 250 ms ±3° 1° Liquid precipitation RAINFALL DURATION The WXT520 has an automatic control circuit that switches the heating on at low temperatures. output resolution and unit Features/Benefits WXT520 ▪ Measures 6 most essentialweather parameters ▪ ▪ Accurate and stable The Vaisala Weather Transmitter WXT520 measures barometric pressure, humidity, precipitation, temperature, and wind speed and direction. ▪ Compact, light-weight ▪ Easy to install with one-bolt mounting method ▪ ▪ ▪ No moving parts ▪ ▪ ▪ USB connection 142 Low power consumption – works also with solar panels Heating available Vaisala Configuration Tool for pc IP66 housing with mounting kit Applications: weather stations, dense networks, harbors, marinas To measure wind speed and direction, the WXT520 has the Vaisala WINDCAP®sensor that uses ultrasound to determine horizontal wind speed and direction. The array of three equally spaced transducers on a horizontal plane is a Vaisala specific design. Barometric pressure, temperature, and humidity measurements are combined in the PTU module using capacitive measurement for each parameter. It is easy to change the module without any contact with the sensors. The WXT520 is immune to flooding clogging, wetting, and evaporation losses in the rain measurement. Measuring acoustic precipitation The WXT520 precipitation measurement is based on the unique Vaisala RAINCAP® Sensor, which detects the impact of individual rain drops. The signals exerting from the impacts are proportional to the volume of the drops. Hence, the signal from each drop can be converted directly to the accumulated rainfall. The WXT520 measures accumulated rainfall, rain intensity and duration of the rain — all in real time. The Vaisala RAINCAP® Sensor is the only maintenance-free precipitation sensor on the market. RAIN INTENSITY range output resolutions and units HAIL & azimuth response time accuracy output resolution and unit output resolutions and units accuracy Δ & DIRECTION RAINFALL Range -52 ... +60 °C (-60 ... +140 °F) Accuracy for sensor at +20 °C ±0.3 °C (±0.5 °F) Accuracy over temperature range (see graph below) cumulative accumulation after the latest automatic or manual reset 0.01 mm, 0.001 inches 5%* counting each ten-second increment whenever water droplet is detected Output resolutions and units 0.1 °C, 0.1 °F Barometric pressure Range Accuracy 600 ... 1100 hPa ±0.5 hPa at 0 ... +30 °C (+32 ... +86 °F) ±1 hPa at -52 ... +60 °C (-60 ... +140 °F) 0.1 hPa, 10 Pa, 0.0001 bar, 0.1 mmHg, 0.01 inHg Output resolutions and units Relative humidity 10 s one-minute running average in ten-second steps 0 ... 200 mm/h (broader range with reduced accuracy) 0.1 mm/h, 0.01 inches/h cumulative amount of hits against the collecting surface output resolutions and units 0.1 hits/cm2, 0.01 hits/in2, 1 hits counting each ten-second increment whenever hailstone is detected output resolution and unit 10 s HAIL INTENSITY one-minute running average in ten-second steps output resolutions and 0.1 hits/cm2h, 1 hits/in2h, units 1 hits/h * Due to the nature of the phenomenon, deviations caused by spatial variations may exist in precipitation readings, especially in a short time scale. The accuracy specification does not include possible wind induced errors. HAIL DURATION For more information, visit www.vaisala.com or contact us at [email protected] Range Accuracy Output resolution and unit 0 ... 100 %RH ±3 %RH within 0 ... 90 %RH ±5 %RH within 90 ... 100 %RH 0.1 %RH General Operating temperature Storage temperature Operating voltage Typical power consumption Heating voltage Serial data interface Weigth Housing Housing with mounting kit -52 ... +60 °C (-60 ... +140 °F) -60 ... +70 °C (-76 ... +158 °F) 5 ... 32 VDC 3 mA at 12 VDC (with defaults) 5 ... 32 VDC / 5 ... 30 VACRMS) SDI-12, RS-232, RS-485, RS-422, USB connection, 650 g (1.43 lb) IP65 IP66 Electromagnetic compatibility Complies with EMC standard EN61326-1; Industrial Environment IEC standards IEC 60945/61000-4-2 ... 61000-4-6 Ref. B210417EN-F ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 143 Wind Power supply WIND SPEED The WMT52 is ideal for use in marine applications as the housing with the mounting kit is water resistant. The WMT52 is also suitable for wind energy and environmental monitoring, for example, for measuring the distribution of air pollution and road tunnel ventilation. Easy to install The WMT52 is delivered fully assembled and configured from the factory. With the Vaisala Configuration Software Tool you can change the settings, such as averaging times, output mode, update intervals, measured variables and message contents. The Vaisala WINDCAP® Ultrasonic Wind Sensor WMT52 - stable and inexpensive wind measurement for demanding applications. Features/Benefits ▪ Measures horizontal wind speed and wind direction ▪ Triangular design ensures excellent data availability ▪ ▪ ▪ ▪ ▪ ▪ ▪ No moving parts 144 Maintenance-free Optional heating available Compact, durable and robust Low power consumption IP66 housing with mounting kit Applications: marine, wind energy, environmental monitoring Proven Vaisala performance The Vaisala WINDCAP® Ultrasonic Wind Sensor WMT52 incorporates decades of Vaisala experience in wind measurement using ultrasound to determine horizontal wind speed and direction. With no moving parts, the WMT52 has high sensitivity as the measurement time constant and starting threshold are virtually zero. This makes it superior to the conventional mechanical wind sensors. The WMT52 is designed to operate without periodic field calibration and maintenance. The WMT52 can be mounted either on top of a pole mast or on a cross arm. When using the optional mounting kit, the north alignment needs to be performed only once. Heating The optional heating available in the WMT52 assists measurements in the freezing weather conditions and during snowfall. As the heating circuit is independent of the operational power, separate supplies can be used. Heating is switched on automatically at low temperatures, well before the freezing point. Range Response time Available variables Accuracy 0 ... 35 m/s 35 m/s ... 60 m/s Output resolution 0 ... 60 m/s 250 ms average, maximum, and minimum ±0.3 m/s or ±3 % whichever is greater ±5 % 0.1 m/s (km/h, mph, knots) WIND DIRECTION 0 ... 360° 250 ms average, maximum, and minimum ±3° 1° MEASUREMENT FRAME Update interval 1 ... 3600 s (=60 min), at one second steps on the basis of samples taken at 4 Hz rate (configurable) 1 ... 3600 s (=60 min), at one-second steps 0.1 mA at 12 VDC 14 mA at 5 VDC 3 mA at 12 VDC (default measuring intervals) 5 ... 32 VDC / 5 ... 30 VACRMS) Mounting kit Bird spike kit Surge protector for sensor Self-diagnostics Start-up Serial data interface Communication protocols Baud rate Operating temperature Storage temperature Dimensions height diameter weight Housing Housing with mounting kit Vibration 212792 212793 WSP150 Electromagnetic compatibility Complies with EMC standard: EN61326-1, Industrial Environment IEC standards IEC 60945/61000-4-2 ... 61000-4-6 Dimensions Dimensions in mm (inches) Ø 115 (4.53) General separate supervision message, unit/status fields to validate measurement quality automatic, <10 s from power on to the first valid output SDI-12, RS-232, RS-485, RS-422, USB connection SDI-12 v1.3, ASCII automatic & polled, NMEA 0183 v. 3.0 with query option 1200 ... 115 200 -52 ... +60 °C (-60 ... +140 °F) -60 ... +70 °C (-76 ... +158 °F) 139 mm (5.7") 114 mm (4.49") 510 g (1.12 lb) IP65 IP66 IEC 60945 paragraph 8 Ø 114 (4.49) mounting kit WINDCAP® is a registered trademark of Vaisala. Low power consumption The WMT52 has very low power consumption; during the idle mode the device typically consumes about 2 ... 3 mW. Heating voltage 5 ... 32 VDC Accessories Azimuth Response time Available variables Accuracy Output resolution Averaging time Operating voltage Power consumption on average minimum maximum typical 99 (3.9) Applications 139 (5.48) WMT52 Ultrasonic Wind Sensor for Accurate and Stable Measurement Technical data 32 (1.3) www.vaisala.com For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210553EN-D ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 145 www.vaisala.com WA15 Wind Set for High Performance Wind Measurement per revolution. This generates a pulse output from the phototransistor. The output pulse rate is directly proportional to wind speed (e.g. 246 Hz = 24.6 m/s). However, for the highest accuracy, the characteristic transfer function should be used to compensate for starting inertia. (See technical data.) Sensitive wind vane The WAV151 is a counter-balanced, low-threshold, optoelectronic wind vane. Infrared LEDs and phototransistors are mounted on six orbits on each side of a 6-bit GRAY-coded disc. Turned by the vane, the disc creates changes in the code received by the phototransistors. The output code resolution is ±2.8°. The WA15 is based on accurate sensors installed on a large crossarm. It is designed for demanding wind measurement applications. With a proven track record of successful installations, the Vaisala Wind Set WA15 has earned its reputation as the industry standard in the wind sensor market. The WA15 consists of a Vaisala Anemometer WAA151, a Vaisala Wind Vane WAV151, an optional crossarm, a power supply and cabling. Anemometer with excellent linearity The WAA151 is a fast response, low-threshold anemometer. Three lightweight, conical cups mounted on the cup wheel, provide excellent linearity over the entire operating range, up to 75 m/s. A wind-rotated chopper disc attached to the shaft of the cup wheel cuts an infrared light beam 14 times Heated bearings withstand cold weather Heating elements in the shaft tunnels of both the anemometer and vane keep the bearings above freezing in cold climates. Complete package available The anemometer and vane are designed to be mounted on Vaisala crossarms. The WHP151 power supply provides the operating and heating power needed for the WA15. The power supply, as well as the signal and power cables are available as options. Technical data Technical data Vaisala Anemometer WAA151 Vaisala Wind Vane WAV151 Wind speed Wind direction Measurement range 0.4 ... 75 m/s Starting threshold < 0.5 m/s * Distance constant 2.0 m Characteristic transfer function U = 0.328 + 0.101 × R (where U = wind speed [m/s], R = output pulse rate [Hz]) Accuracy (within range 0.4 ... 60 m/s) with characteristic transfer function ± 0.17 m/s ** with transfer function U = 0.1 × R ± 0.5 m/s*** Measurement range at wind speed 0.4 ... 75 m/s Starting threshold Resolution Damping ratio Overshoot ratio Delay distance Accuracy General General Operating power supply Uin = 9.5 ... 15.5 VDC, 20 mA typical Heating power supply AC or DC 20 V, 500 mA nominal Output 0 ... 750 Hz square wave Transducer output level high state > Uin-1.5 V with Iout < +5 mA low state < 2.0 V with Iout > –5 mA Settling time after power turn-on < 30 μs Plug 6-PIN MIL-C-26482 type Cabling 6-wire cable through crossarm Recommended connector at cable end SOURIAU MS3116F10-6P Operating temperature with heating -50 ... +55 °C (-58 ... +131 °F) Storage temperature -60 ... +70 °C (-76 ... +158 °F) Material housing AlMgSi, grey anodized cups PA, reinforced with carbon fibre Dimensions 240 (h) × 90 (Ø) mm Swept radius of cup wheel 91 mm Weight 570 g Operating power supply Uin = 9.5 ... 15.5 VDC, 20 mA typical Heating power supply AC or DC 20 V, 500 mA nominal Output code 6-bit parallel GRAY Output levels high state > Uin –1.5 V With Iout < +5 mA low state < 1.5 V With Iout > –5 mA Settling time after power turn-on < 100 μs Plug 10-PIN MIL-C-26482 type Cabling 10-wire cable through crossarm Recommended connector at cable end SOURIAU MS3116F12-10P Operating temperature with heating -50 ... +55 °C (-58 ... +131 °F) Storage temperature -60 ... +70 °C (-76 ... +158 °F) Material housing AlMgSi, grey anodized wave Alsi 12 anodized Dimensions 300 (h) × 90 (Ø) mm Swept radius of vane 172 mm Weight 660 g Test compliance Test compliance Wind tunnel tests Exploratory vibration test Humidity test Salt fog test ASTM standard method D5096-90 MIL-STD-167-1 MIL-STD-810E, Method 507.3 MIL-STD-810E, Method 509.3 Complies with EMC standard EN61326-1:1997 + Am1:1998 + Am2:2001; Generic Environment Vaisala Wind Set WA15 Features/Benefits Options and accessories ▪ ▪ High-performance wind measurement set ▪ ▪ ▪ Accurate wind speed and direction measurement ▪ Heated shaft prevents bearings from freezing Crossarm and termination box 16-lead signal cable 6-lead power cable Crossarm and analog transmitter 6-lead cable for signal and power Crossarm and serial RS485 transmitter Serial RS485 transmitter card Power supply Set of bearings and gasket Cup assembly Tail assembly Long and successful track record in meteorological applications Low measurement starting threshold Conical anemometer cups provide excellent linearity 146 0 ... 360° <0.4 m/s ±2.8° 0.19 0.55 0.4 m better than ±3° Wind tunnel tests ASTM standard method D5366-93 (for starting threshold, distance constant, transfer function) Exploratory vibration test MIL-STD-167-1 Humidity test MIL-STD-810E, Method 507.3 Salt fog test MIL-STD-810E, Method 509.3 Complies with EMC standard EN61326-1:1997 + Am1:1998; Am2:2001; Generic Environment * WAC151 ZZ45048 ZZ45049 WAT12 ZZ45049 WAC155 WAC155CB WHP151 16644WA 7150WA 6389WA Measured with cup wheel in position least favoured by flow direction. Optimum position gives approx. 0.35 m/s threshold. ** Standard Deviation *** Typical error vs. speed with the "simple transfer function" used. RANGE (m/s) ERROR (m/s) 0-3 -0.4 3-10 -0.3 10-17 -0.2 17-24 -0.1 24-31 0.0 31-37 +0.1 37-44 +0.2 44-51 +0.3 51-58 +0.4 For more information, visit www.vaisala.com or contact us at [email protected] 58-65 +0.5 Ref. B210382EN-B ©Vaisala 2009 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. 147 Vaisala Service Offering 10 D Gill Street, Woburn, MA 01801 USA and Canada Tel: 1-888-VAISALA (824-7252) Brazil: 0800-891-7392 International Calls: + 781-933-4500 Fax: + 1-781-933-8029 Email: [email protected] www.vaisala.com/SERVICE Vaisala Service Offering Vaisala offers you calibration and maintenance services. You can choose from different options to customize your service agreement to cover all your Vaisala instruments. Easy and efficient calibration Calibration is an essential part of measurement instrument maintenance. We offer Service agreements designed to fulfill your calibration and maintenance needs. Your instruments can be enrolled in the Calibration Reminder Program, which provides advance notification when regular calibration is due. For most Vaisala instruments, it also includes a calibration certificate with the 'before' and 'after' adjustment data. You can choose a standard (factory) calibration or accredited calibration for a certain period of time. The standard (factory) calibration is traceable and ISO 9001 compliant. The standard accreditation e.g. for Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT330 includes seven humidity and one temperature point at room temperature. Vaisala also offers accredited calibrations for many of its products. Vaisala Service Centers are accredited and their working procedures are approved by third party organizations. This is confirmed by the name and logo of the local accrediting body appearing on the report documentation. The documentation includes uncertainty calculations. Accredited calibrations are recommended especially for the measurement instruments that are used as transfer standards or in demanding measurement applications. All accredited calibrations comply with ISO 17025 and are traceable to international standards. Service and Calibration Standards Laboratory – Lifetime Accuracy from the Vaisala Service Center Add benefits with options Features/Benefits The Vaisala Service Agreements are available with multiple optional services. You can select the options based on your needs. r r r r ▪ SCHEDULED PART DELIVERY: With this option Vaisala will keep an exchange unit (or units) in stock which will be shipped to you before the recommended calibration or maintenance time. ▪ PRIORITY TECHNICAL SUPPORT: Priority technical support increases uptime of your operations. Our response time to your technical inquiries can be agreed according to your need. You can also customize your calibration agreement, when needed. Lifetime accuracy with Vaisala service agreement Regular maintenance is a key factor in ensuring measurement accuracy. ▪ A Vaisala Service Agreement is a convenient way to gain access to professional support over the life cycle of your instruments. Agreements can be customized to support highest uptime and accuracy of your instruments. A Vaisala Service Agreement is designed to fulfill customer needs – we will proceed step by step to find out the most suitable solution for your application. Let us do the job and you can concentrate on the results! ▪ ▪ NIST traceable, ISO 9001:2000 5 day turnaround for calibrations Express service option ANSI-Z540 and ISO 17025:2005 compliant r "-"BDDSFEJUBUJPO r Calibration Reminder Program provides advance notification when regular calibration is due. r FREE one year extended warranty with calibration r Spare parts r Reliable and professional standard calibrations Using high quality instruments, the Vaisala Service Center performs calibration and adjustments in controlled environments. EXTENDED WARRANTY: Secure your investment against accidental breakdowns for years to come – let Vaisala carry the risk of unpredictable repairs. You get all the benefits of Vaisala’s standard warranty conditions, but for much longer. Vaisala lifetime accuracy Vaisala’s state-of-the-art Service Center and Calibration Standards Laboratory (CSL) provides service, calibration and adjustment for Vaisala’s relative humidity, dewpoint, material moisture, barometric pressure and carbon dioxide instruments. CALIBRATION REMINDER PROGRAM: By joining the Calibration Reminder Program, you'll receive a reminder for your upcoming calibration, along with detailed information on how to get the units calibrated at our service centers. ISO and A2LA Accreditation The CSL received from the American Association for Laboratory Accreditation (A2LA) certification to ISO/IEC 17025:2005. The CSL is also certified to ISO 9001:2000 and meets the requirements of ANSI/NCSL Z540-1-1994. As a result the CSL is able to offer accredited calibrations for humidity, dewpoint and temperature instruments. REPAIR AND CALIBRATION: Vaisala Returns On the Web (ROW) is a system for easy shipping of Vaisala instruments for calibration or repair. The system processes your service order step-by-step and produces all required shipping documents and instructions needed. Standard calibration Calibration is an integral part of instrument maintenance. Vaisala Service performs multi-point and accredited calibrations and adjustments to ensure measurement accuracy. One-point, on-site field calibrations are useful in identifying the need for additional calibration and adjustment. 148 Multi-point calibrations offer the advantage of high accuracy over the entire measurement range. Certificate verifies performance – both before and after To verify results, a certificate is issued for each calibrated instrument. The certificate shows the readings both before and after adjustment. This system enables the user to easily monitor the performance of the calibrated instrument. Accredited calibration Accredited calibrations ensure the highest measurement accuracy and are directly traceable to international standards. The measurement uncertainty in accredited calibrations is presented for all measurement points. Accredited calibration is recommended for instruments that are used as a transfer standard, other demanding measurement applications, and/or to meet standards. Calibration Reminder Program with FREE Extended Warranty ISO 9001 accreditations are recognized by major international accreditation organizations. 2083.01 Vaisala CSL is in compliance with ISO/IEC 17025:2005 and ANSI/NCSL Z540-1-1994 A2LA accreditation. Quality systems require calibration tracking. Participants in the Vaisala Calibration Reminder Program automatically receive a ‘time to re-calibrate’ notice. If the instrument is sent to Vaisala for recalibration within the initial warranty period, the warranty will be extended for one year – FREE. Customer Support The Vaisala Help Desk, staffed by technical support engineers, is ready to provide assistance. Call: 888.VAISALA (824.7252) or Email: [email protected] 149 SERVICE Calibration is Our Core Operation All Vaisala calibrations comply with ANSI-Z540-1-1994 ISO/IEC 17025:2005 calibrations are also available. Humidity Calibration NIST traceable calibrations. Standard calibrations consist of four points with adjustments at 0% and 75.5% and linearity checked at 11.3% and 33 %RH, (97.6 %RH optional). Two-pressure generator enables special NIST traceable calibrations: r "OZQPJOUTCFUXFFOUP3) r 5FNQFSBUVSFSBOHFw'UP$ Temperature Calibration r 5FNQFSBUVSFDBMJCSBUJPOTGSPNUP$ UP' r /*45 USBDFBCMF UFNQFSBUVSF DBMJCSBUJPO XJUIJO UIF specified range. Dewpoint Calibration r %FXQPJOUDBMJCSBUJPOTGSPNUP'UP$ r /*45USBDFBCMFEFXQPJOUDBMJCSBUJPOXJUIJOUIF specified range. CO2 Calibration r $FSUJóFE$02 calibration r $BMJCSBUJPOBU 0%: 2,000 ppm (0.2%); 3,000 ppm (0.3%); 5,000 ppm; 10,000 ppm; 20,000 ppm 5%: 10% and 20% Warranty Repair of Vaisala Instruments For warranty repairs, no authorization from the customer is needed. Vaisala guarantees a one week turnaround from the date the instrument(s) are received. Non-Warranty Repair of Vaisala Instruments For non-warranty repairs, you will be notified of the repair charge within one week of the lab receiving the instrument(s). Vaisala guarantees a one week turnaround from the authorization date. Express Service Two-day guaranteed turnaround service is available for a nominal fee. When obtaining an RMA number please inform the Customer Service Representative if this service is desired. Maintenance Contracts Maintenance contracts are available on an individual basis. Call your sales engineer to discuss the posibilities. 1-888-VAISALA (824-7252) 150 Returning for Service For service, call Vaisala’s customer service department at 1-800-408-9454. A Customer Service Representatives will assign an RMA (Return Material Authorization) number for returning the Vaisala instrument for recalibration or repair. Please reference this RMA number on all paperwork, and write it on the outside of the return package. Contact Information: Vaisala North American Service Center Vaisala Inc. 10-D Gill Street Woburn, MA 01801 Tel: 781-933-4500 1-888-VAISALA (824-7252) Fax: 781-933-8029 Customer Service: Tel: 1-800-408-9454 Email: [email protected] Technical Support: Tel: 1-800-408-9456 Email: [email protected] Web: www.vaisala.com/reminder Extend Your Warranty for Free! Standard (factory) Calibrations Service Center European Service Center Asian Service Center North American Service Center Location Helsinki, Finland Tokyo, Japan Boston, MA, USA Humidity √ √ √ Temperature √ √ √ Dewpoint Temperature √ √ √ Barometric Pressure √ √ √ Table 1. Standard (factory) calibration is available globally in all Vaisala Service Centers. Traceability of Measurement Parameters ISO9001 compliant ISO17025 compliant Standard Calibration Traceability Accredited Calibration Traceability Relative Humidity Yes NIST Yes JCSS/NIST, Salt Solutions Temperature Yes NIST Yes NIST Dewpoint Temperature Yes NIST, JCSS Yes JCSS Barometric Pressure Yes NIST Yes NIST Carbon Dioxide Yes NIST, NMI Not available – Table 2. Traceability of different measurement parameters. Accredited Body Service Center European Service Center Asian Service Center North American Service Center Location, Laboratory, Code Helsinki, Finland, K008 Tokyo, Japan, 0123 Boston, MA, USA, 112765 Calibration Reminder Program Accredited Parameters Register for Vaisala’s Recalibration Reminder Program and extend your warranty FREE! Call 1-800-408-9454. Relative Humidity √ Temperature √ Dewpoint Temperature Barometric Pressure √ √ √ √ √ √ Table 3. Accredited parameters in Vaisala Service Centers. 151 PRICE LIST PRICE LIST FIXED PRICES for CALIBRATION and REPAIR (Effective 1/1/10) Shipping charges are not included in pricing. PSERVDA Digital Repair and Calibration (Class A) ................................................................................................... $395 Order Code: HUMIDITY: 5 Day Turn-around PTUSERV PTU300/PTU200 Repair and Calibration ................................................................................................... $495 RHCALA 2% Standard Calibration* (0, 11, 33, 75% RH)........................................................................................... $150 HMW60/70 wall mount, (0, 33, 75 %RH) .................................................................................................... $100 URGENTFEE Analog: 2-day turn-around from date unit received....................................................................................... $50 Digital: 2 week turn-around .......................................................................................................................... $95 RHCALD 1% Calibration** (0, 11, 33, 75%RH) .......................................................................................................... $200 Option of 97% available in place of any point or, 5 point including 97% for an additional fee of .................. $75 Oxygen calibration: 4-Week Turn-around With high end calibration one of the adjustments is done at 97%RH. OMT355 Calibration 0 - 21% .................................................................................................................................... $330 Resulting accuracy is: ±3 or 2% < 90 %RH and ± 2 or 1% > 90 %RH. OMT355 Calibration 0- - 100% ................................................................................................................................. $622 COMBOCAL Combination Calibration (5-point RH Cal 0, 11, 33, 75, 97 + 3-point Temp Cal 0°, 50°, 100 °C)................$425 DTS1 Calibration: RHSERVA RHSERVD Repair and 2% Calibration* ....................................................................................................................... $250 Repair and 1% Calibration (Non Sensing Head Units) ............................................................................... $500 DTSCAL DTS1SERV1 Calibration ....................................................................................................................................... $ 200 Calibration & sensor replacement (Minor Repair) ...................................................................................... $500 RHSERVD-SHC Repair and 1% Calibration** (Sensing head included) ............................................................................... $600 DTS1SERV2 Calibration & Major Repair ......................................................................................................................... $700 ANALOGCAL1 Forced output, 3-points at min, mid, max of scaling.....................................................................................$100 ANALOGCAL2 Actual values measured on outputs during calibration............................................................. ...................$100 RHCALPOINT Special Humidity including certificate (11%…95% @ 0…70 °C): ambient (Room Temperature) ......................................................................... $95 elevated temperatures .................................................................................. $150 2 Day Express Service (on RHCALA & RHCALD only) per unit (Not available on dewpoint products, Accreditation/ or special points.) ................................................................................................................ $50 .......................................................................................................................................................................$100 URGENTFEE EVALUATION * The Standard Calibration consists of a 4 point calibration with adjustments made at 0% and 75.5% and linearity checked at 11.3% and 33%. Temperature is verified at ambient.HMP42 Repair is RHSERVD ** 1% Calibration is standard for the HMP230 Series, HMP240 Series, HMP260 Series, HMI38 with HMP35E/36E/37E, HMT360 Series, HMI41/HMP46, HMT330 Series and HMP70 Series. ISO 17025 Accredited Calibrations for Humidity, Temperature, Dewpoint and Pressure - See pages 202-209 TEMPERATURE: 5-7 Day Turn-around: includes certificate Calibration per point; minimum 2 points (range -80 °C …180 °C based on model) .................................... $75 Temperature Respanning for HMD/W 20/30, 60/70,& 61/71 units ................................................................ $50 sTemperature spans must be 40 °C (72 °F) apart for HMD/W 20/30, HMD/W60/70, and 61/71 units CARBON DIOXIDE: 5 Day Turn-around Calibration (Zero and Span) (2000, 3000, 5000, 10,000, 20,000 PPM …1, 2, 3, 5, 10, 20%) ................... $125 Repair and Calibration ............................................................................................................................... $250 Calibration of GMP220 probes (3 points) ................................................................................................... $200 TCAL RESPAN CO2CAL CO2SERV CO2CALIND CO2SERVIND 216873 217084 216880 DEWAL-STD DEWCAL DEWCAL5 DEWSERV DEWSERV5 Repair and Calibration of GMP220 probes ................................................................................................. $400 GM70 Pump Service ................................................................................................................................. $600 GMP343 Calibration (4-week turn-around) ................................................................................................ $350 GMP343 Repair (4 week trun-around) ...................................................................................................... $650 DEWPOINT: 5 to 10 Day Turn-around; includes certificate 3 point calibration (-50, -30, +10 °C) Production Calibration Points ........................................................... $300 3 point calibration (-40, -30, -20 °C) (Range -70…+20 C°)......................................................................... $300 NOTE: $100 per point for -70…+20°C, $125 per point for +20…60 °C 5 point calibration (-50, -40, -30, -20, -10 °C) ............................................................................................ $450 3 point repair and calibration (-40, -30, -20 °C) ......................................................................................... $600 5 point repair and calibration (-50, -40, -30, -20, -10 °C) ........................................................................... $700 s$%7#!,#ALIBRATIONISSTANDARDFORTHE$-0AND$-4 PCALDB PSERVA 200 152 PRESSURE: Digital 3 Week Turn-around; Analog 1 Week Turn-around includes certificate Analog Calibration (Class B, 1 week turn-around) ..................................................................................... $125 Analog Repair and Calibration (Class B) ................................................................................................... $400 PTB100A, PTB101C & PTA427, 6 point calibration @ 800, 850,900,950,1000,1050 hPa PTB100B & PTB101B, 8 point calibration @ 600, 700, 800, 850, 900,1000, 1050 hPa Prices in U. S. dollars. Prices are subject to change without notice. A 25% restocking fee for returned products. WIND: 3 Week Turn-around WSSERV Upgrades and Software WXT510 & WS425 ............................................................................................... $250 Mechanical Sensors .................................................................................................................................. $600 Ultrasonic Sensors - Evaluation ................................................................................................................ $100 Ultrasonic Sensors - Repair ....................................................................................................................... $750 WXT and WMT50 - Functional testing and/or PTU replacement................................................................ $250 WXT520 Service/WXT510 upgrade to WXT520 ........................................................................................ $450 NOTE: WS425 units with orange transducers cannot be repaired. UNIT UPGRADES: Upgrade to All Parameters Version (Software): ......................................................................................... $600 Upgrade HUMICAP from an H180 sensor to H180R sensor ..................................................................... $400 Upgrade HUMICAp from an H180C sensor to H180RC sensor ................................................................ $600 Adding Display/Keypad: HMT330 Series any single upgrade (i.e. software/display and analog channel) ........................................ $600 HMP230 Series ......................................................................................................................................... $600 HMT100 Display ........................................................................................................................................ $500 HMT360 Series .......................................................................................................................................... $600 GMT220 Series ......................................................................................................................................... $400 PTB220, PTB330, PTU300 Series ............................................................................................................ $600 Adding Second Channel: HMT360 Series........................................................................................................................................... $600 NOTE: All prices listed above include RH Calibration and Certificate Adding Data Logging or w/LANMofule Unit w/5.0SW ............................................................................................................................................. $600 Unit w/4.0SW .............................................................................................................................................. $800 Adding Analog Output Option: PTB220, (Sent to Helsinki) PTB330, PTU300 .......................................................................................... $600 NOTES: Pricing: Prices are subject to change without notice. All prices are FOB Woburn, MA. Shipments: Express Service, for next day shipments (if available) $50. Returns/Restocking: Unless otherwise noted on the Order Guides, standard unused products if resaleable as new, can be returned within 90 days of purchase with a Return Materials Authorization (RMA). A 25% restocking fee will be charged for all returned products. Service Repairs: A Return Material Authorization (RMA) is necessary prior to sending products to Vaisala for repair. Vaisala, Inc. 10-D Gill Street Woburn, MA 01801 Toll Free: 888-VAISALA (824-7252) Tel: 781-933-4500 Fax: 781 933-8029 Customer Service Toll Free: 1-800-408-9454 Email: [email protected] Technical Support Toll Free: 1-800-408-9456 Email: [email protected] Prices in U. S. dollars. Prices are subject to change without notice. A 25% restocking fee for returned products. 201 153 www.vaisala.com DMT132 Dewpoint Transmitter for Refrigerant Dryers Features / Benefits ▪ Affordable dew point transmitter for refrigerator dryers ▪ High accuracy ±1°C (±1.8°F) in the measurement range of refrigerator dryers ▪ Excellent long-term stability resistant to compressor oil and most other chemicals thanks to HUMICAP® technology ▪ Low power requirements, 10 .... 28 VDC ▪ Easy to verify functionality with compatible hand-held meters DM70 or HM70 ▪ Optional LED warning light The optional LED warning light tells the user when the defined dew point limit has been exceeded. The Vaisala HUMICAP® Dewpoint Transmitter DMT132 is an affordable dew point measurement instrument designed to verify the functionality of refrigerant dryers. It is especially well suited for OEM dryer manufacturers. Direct measurement cuts costs Direct outlet air dew point measurement provides accurate information about dryer functionality and is more reliable than the traditional method of measuring refrigerator temperature only. Knowledge of the real dew point ensures high quality compressed air at all times and enables customers to optimize dryer capacity. This helps to prevent investment in redundant dryer capacity and avoid unnecessary maintenance and costly malfunctions. High accuracy and long-term stability The DMT132 provides optimal performance in the operating range of refrigerant dryers. In the measurement range of -3… 20°C (+26.6…+68°F), where the refrigerator dryers typically operate, the Td accuracy is ±1°C (±1.8°F). The instrument incorporates the proven Vaisala HUMICAP® sensor, which is resistant to compressor oil and most other chemicals, thereby providing excellent long-term stability. DMT132 operating voltages can be as low as 10 VDC. Verifying the performance of the DMT132 is easy with the compatible Vaisala hand-held DM70 or HM70 meters. The user can perform possible adjustments with the Vaisala HMK15 Humidity Calibrator. Quick installation and easy field checking It takes just a few minutes to install the DMT132 directly into a dryer or compressed air line through a G1/2” ISO thread. Vaisala sampling cells can also be used. The loop-powered electronics mean that wiring is easy and power requirements are low. Demand for dew point sensors to verify refrigerant dryers is increasing. Direct dew point measurement enables energy savings and improved efficiency. Technical data Performance General Dewpoint Sensor Vaisala HUMICAP®180R Recommended calibration interval 2 years (in refrigerant dryer application) Mechanical connection G 1/2" ISO Operating voltage 10 .... 28 VDC External load max 100 ohm for supply voltages <20 VDC max 500 ohm for supply voltages 20...28 VDC Weight 65 g (2.3 oz) Housing material PPS + 40% GF Housing classification IP65 (NEMA 4) Storage temperature range -40 ... + 80 °C (-40 ... +176 °F) Start-up time 3s Complies with EMC standard EN61326-1, Electrical equipment for measurement control and laboratory use - EMC requirements; Industrial environment Measurement range -20 ... +50 °C (-4 ... +122 °F) Td Accuracy (at +20 °C (+68 °F)) ±1 °C for -3...20 °C (+26.6 ... +68 °F) Td ±2 °C for -15...-3 °C (+5 ... +26.6 °F) Td see accuracy graph below * when dewpoint is below 0 °C (+32 °F), the transmitter outputs frostpoint Response time at 20 °C (+68 °F) gas temperature and 1 bar pressure -20 -> +50 °C (-4 -> +122 °F) Td 17 s (63%) 40 s (90%) +50 -> -20 °C (+122 -> -4 °F) Td 33 s (63%) 85 s (90%) Calculated variables Dewpoint converted to atmospheric pressure Tdf atm Dewpoint temperature (°C) 60 50 Options and accessories 40 30 20 Accuracy ±1 °C 10 0 Accuracy ±2 °C -10 -20 -30 -10 0 10 20 30 40 50 60 Temperature of measured gas (°C) Operating environment Operating temperature Operating pressure Relative humidity Sample flow rate Measured gases -10 ... + 60 °C (+14 ... +140 °F) 0 ... 20 bar 0 ... 100 %RH no effect on measurement accuracy non-corrosive gases Tube filter 230602 Special cover set for HMK15 (calibrator fitting DMT132 and HMP60) 230914 NPT Adapter 210662SP Sample cells DMT242SC, DMT242SC2, DSC74, DSC74B, DSC74C, DMCOIL Duct installation flange DM240FA Cables (several lengths HMP50Z032, HMP50Z300SP, available) HMP50Z500SP, HMP50Z1000SP Loop powered external display 226476 USB Service cable 219690 Connection cable to DM70/HM70 219980 LED plug 230388 ISO" 1/2 plug 218773 NPT1/2" plug 222507 Sealing ring set (3 pcs U-seal) 221525SP Outputs For more information, visit www.vaisala.com or contact us at [email protected] 80.5 6 125.5 45 2.5 12 AW 30 R1 9.5 33 Analog output (scalable) 4...20 mA, 2-wire Resolution for current output 0.002 mA Accuracy of analog outputs at +20 °C ±0.05% full scale Typical temperature dependence ±0.005% of full scale/ °C Connector 4-pin M8( (IEC 60947-5-2) LED indication available for defined dewpoint limit/ error state indication RS485 serial line for service use G1/2" ISO 228-1 Ref. B211105EN-A ©Vaisala 2011 36 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. Accredited Humidity & Temperature Calibration ACCREDITED HUMIDITY CALIBRATION The relative humidity calibration is performed at room temperature using a Thunder Scientific 2500 TwoPressure Generator. The calibration uncertainty typically ranges from ± 0.60 to ±1.1 %RH. A onepoint temperature calibration is performed at ambient. The calibration procedure used for calibrations is 11603108-CSL Humidity Calibration. Ordering a calibration that complies with the requirements of ISO/IEC 17025:2005 Calibration for Vaisala humidity and temperature transmitters and probes can easily be ordered using this form. Please read the form and notes carefully and complete the form accurately to ensure correct calibration service. The form must be completed in full before calibration services can start. Include the form with your instrument. For additional information please contact Vaisala at 1-800-408-9454. Instrument Details Customer Name: Thunder Scientific 2500 Two-Pressure Generator saturates a continuous stream of gas with water vapor at a known pressure and temperature, and passes it through an expansion valve where it expands to a lower pressure. ACCREDITED TEMPERATURE CALIBRATION The temperature calibration is made using Hart Scientific liquid bath with a Black Stack reference. The calibration uncertainty is typically ±0.02 °C. The calibration procedure used for calibration is 11603135CSL Temperature Calibration. Hart Scientific liquid baths are used as the calibration method. A Hart Scientific Black Stack/PRT combination is used as the reference standard. The Black Stack uses a high accuracy display module, model 1560 as the readout indicator. The PRT is immersed in the liquid of the bath. CALIBRATION DETAILS The instrument will be adjusted to comply with its specifications (if needed) unless no adjustment is requested. Out of tolerance conditions are determined by the product specification only. The calibration Model No(s): Serial No(s): Calibration Laboratory Certificate #: 2083.01 ISO/IEC 17025:2005 CALIBRATION DETAILS CONTINUED uncertainty is not tied in with the instrument's accuracy. All results are reported in a calibration certificate, which is written according to the ISO/IEC 17025:2005 standard. ACCREDITATION Accreditation is a third party formal recognition that a laboratory is competent to carry out specific calibrations. The American Association for Laboratory Accreditation (A2LA) has assessed Vaisala’s Calibration Standards Laboratory (CSL) for humidity and temperature calibrations. The accreditation standard used is ISO/IEC 17025:2005. A2LA accreditation is recognized by all the major international accreditation organizations. Calibration Details Price Humidity Calibration Performed at ambient temperature. Includes 1-point ambient temperature calibration. Extra points are $95 each (example: 7 points = $545). Please specify custom points below. 0 Points A B C D E No Humidity Calibration 4 Points 0, 11, 50, and 80 %RH 6 Points 0, 11, 30, 50, 70, and 90 %RH 8 Points 0, 11, 30, 50, 60, 70, 80, and 90 %RH 10 Points 0, 11, 30, 40, 50, 60, 70, 80, 90, and 95 %RH SI – International System of Units SI – International System of Units National Level (USA) National Institute of Standards and Technology (NIST) National Institute of Standards and Technology (NIST) CSL Primary Standard: MBW Chilled Mirror Hygrometer Hart Scientific $0.00 $325.00 $450.00 $600.00 $750.00 Temperature Calibration - Specify Points Below Test points must be between -80 °C and 180 °C and within the model’s measurement range. 0 Points No Temperature Calibration 3 Points 1_____ 2_____ 3_____ °C / °F 5 Points 1_____ 2_____ 3_____ 4_____ 5_____ 7 Points 1_____ 2_____ 3_____ 4_____ 5_____ 6_____ 7_____ 9 Points 1_____ 2_____ 3_____ 4_____ 5_____ 6_____ 7_____ 8_____ 9_____ °C / °F °C / °F °C / °F A B C D E $0.00 $225.00 $350.00 $450.00 $550.00 Units of Results Reported A B Humidity %RH, Temperature °C International Level Secondary Level Accredited Humidity & Temperature Calibration Humidity %RH, Temperature °F $0.00 $0.00 Adjustment Calibration prices include adjustment (if needed). Check here if you DO NOT want your instrument adjusted. Customer Information To Appear On Certificate Company Name (if different than above): Address: CSL Primary Std.: Hart Scientific Super-Thermometer/SPRT CSL Standard: Thunder Scientific 2500 Generator CSL Standard: Hart Scientific Black Stack/PRT Requested Due Date For Next Calibration: Customer Asset #: Received And Accepted At Vaisala Customer Level Calibration for Customer Working Standards Calibration for Customer Working Standards Traceability chain for humidity calibration Traceability chain for temperature calibration 11604121 – Rev. B 154 Name & Date: Contract #: NOTE: The calibration prices include a Calibration Certificate, but do not reflect repair charges. Repair charges will utilize fixed pricing: Analog repairs: $125.00, Digital repairs: $350.00 11604121 – Rev. B 155 Accredited Dewpoint Calibration Accredited Dewpoint Calibration Ordering a calibration that complies with the requirements of ISO/IEC 17025:2005 Calibration for Vaisala humidity and temperature transmitters and probes can easily be ordered using this form. Please read the form and notes carefully and complete the form accurately to ensure correct calibration service. The form must be completed in full before calibration services can start. Include the form with your instrument. For additional information please contact Vaisala at 1-800-408-9454. ACCREDITED DEWPOINT CALIBRATION The dewpoint calibration is made using a Thunder Scientific 3900 Two-Pressure Generator at room temperature. The calibration uncertainty is typically from 0.2 oC. A one-point temperature calibration is performed at ambient. The calibration procedure used for calibration is 11603134-CSL Dewpoint Calibration. The Thunder Scientific 3900 Two-Pressure TwoTemperature Generator saturates a continuous stream of air or nitrogen with water vapor at a known pressure and temperature. The saturated high-pressure gas then passes through an expansion valve where it expands to a lower pressure. To generate a particular humidity the 3900 first selects a suitable saturation temperature. It then determines the saturation pressure required to establish the correct saturation vapor pressure. CALIBRATION DETAILS The instrument will be adjusted to comply with its specifications (if needed) unless no adjustment is requested. Out of tolerance conditions are determined by the product specification only. The calibration uncertainty is not tied in with the instrument's accuracy. All results are reported in a calibration certificate, which is written according to the ISO/IEC 17025:2005 standard. International Level Instrument Details Customer Name: Model No(s): Calibration Laboratory Certificate #: 2083.01 ISO/IEC 17025:2005 ACCREDITATION Accreditation is a third party formal recognition that a laboratory is competent to carry out specific calibrations. The American Association for Laboratory Accreditation (A2LA) has assessed Vaisala’s Calibration Standards Laboratory (CSL) for humidity and temperature calibrations. The accreditation standard used is ISO/IEC 17025:2005. A2LA accreditation is recognized by all the major international accreditation organizations. Serial No(s): Calibration Details Price Dewpoint Calibration - Specify Points Below Dewpoint points must be between -60 °C and -10 °C and within the model’s measurement range. 3 Points 1:______ 2:______ 3:______ 4 Points 1:______ 2:______ 3:______ 4:______ 5 Points 1:______ 2:______ 3:______ 4:______ 5:______ A B C $500.00 $625.00 $750.00 Units of Results Reported A B Humidity %RH, Temperature °C Humidity %RH, Temperature °F $0.00 $0.00 Adjustment Calibration prices include adjustment (if needed). Check here if you DO NOT want your instrument adjusted. Customer Information To Appear On Certificate Company Name (if different than above): Address: SI – International System of Units Requested Due Date For Next Calibration: National Level (USA) Secondary Level National Institute of Standards and Technology (NIST) CSL Primary Standard: MBW Chilled Mirror Hygrometer CSL Standard: Thunder Scientific 3900 Generator Customer Level Customer Asset #: Received And Accepted At Vaisala Name & Date: Contract #: NOTE: The calibration prices include a Calibration Certificate, but do not reflect repair charges. Repair charges will utilize fixed pricing: Analog repairs: $125.00, Digital repairs: $350.00 Calibration for Customer Working Standards Traceability chain for dewpoint calibration 11604122 – Rev. B 156 11604122 – Rev. B 157 Vaisala Filters Vaisala Filters continued Group A: 12 mm Diameter, Standard Length, Female Threads Group C: 12 mm Diameter, 0195 Brass, sintered filter, 133 microns, ø 12.0 mm Use with: HMM20/30, HMP130,HMP36, HMP46 Group: A 0195 Male Threads 17039HM Membrane filter 0.2 μm, ø 12 mm Use with: HMD60/70/40/50 HMP44, HMP141/143 Group: C 10159HM Membrane filter, 0.2 microns, ø 12.0 mm Use with: HMD20/30, HMM20/30, HMP133, HMP75, HMM100 Group: A 17039HM 10159HM DRW010522 HM46670SP Sintered stainless steel filter , 38 μm, ø 12.0 mm Use with: HMP50, HMM210, HMT100, HMD60/70 Group: C 6221 Plastic grid, 2 mm protection, ø 12.0 mm Use with: HM34, HMD20/30,HMM20/30,HMP133, HMP75, HMM100 Group: A 6221 HMM46670SP Group B: 12 mm Diameter, Long Length, Female Threads (Could be used in place of “A” type filters) Group D: 13.5 mm Diameter, Male Threads DRW010276SP PPS plastic grid filter, 6.5 mm, ø 12 mm Use with: DTS1, HMT330, HMP76/77, MMT310 Group: B DRW010276SP HM47280SP Stainless steel sintered filter , 38 μm, ø 12mm Use with: HMT330, HMP76/77, DM70, DMT242, DMP74, DMT142,HMM20/30, MMT310, DMT340, HMM100 Group: B DRW212987SP Sintered filter, 40 μm, ø 12 mm Use with: HMP76/77, HMP75 Group: B DRW010525 17230HMSP PTFE membrane, 3.5 μm, ø 13.5 mm. Use with: HMP230, HMP228, HMT360 Group: D 17230HMSP 16562SP PPS Grid, 2 mm, ø 13.5 mm Use with: HMP230, HMP37, HMP228, HMT360, PTU200 Group: D HM47453SP Stainless steel filter guard for vacuum, 3.15 mm, ø 12 mm Use with: DM70, DMT242, HMP228, DMT340, HMT310, MM70, MMT310, DMT142, MMT330 Group: B HM46999SP Sintered stainless steel filter, 2mm, ø 13.5 Use with: DMP248, HMT360, HMP237 Group: D HM46999SP 16562SP HM47453SP DRW010525 Membrane filter, 0.2 μm, ø 12 mm Use with: HMW61/71 Internal HMD60/70, HMP50, HMT100 Group: C 16452SP Sintered filter, stainless steel, 37 microns, ø 13.5 mm Use with: DMP248, HMP230, HMP228, HMT360 Group: D 16452SP HM47280SP DRW010281SP PPS plastic grid with stainless steel nettng, 15 μm, ø 12 mm Use with: DTS1, HMT330, HMP76/77, MMT310 Group: B DRW010281SP DRW010522 Plastic Grid, 2 mm, ø 12 mm Use with: HMP50, HMT100 Group: C 16720HMSP PPS Grid and stainless steel net, 14 μm, ø 13.5 mm Use with: HMP230, HMT360, HMP37E Group: D 219452SP Sintered PTFE filter, ø 12 mm Use with: HMP155, HMM100 Group: B 16720HMSP DRW212987SP 158 219452SP 159 Order Guides Vaisala Filters continued Order Guides HMT331 Humidity and Temperature Transmitter For wall mounting Group E: 18.5 mm Diameter, Female Threads 1 2 2787HM Membrane filter, 0.2 microns, ø 18.5 mm Use with: HMM30, HMP35,HMP45,PTU200, HMW21/31 Group: E 6597 Plastic grid, 2.5 mm, ø 18.5 mm Use with: HMM30N,HMP131, HMP35, HMP45A/D Group: E 3 4 5 6 7 6597 2787HM HM46717 Plastic grid, 2.5 mm, ø 18.5 mm Use with: HMP41, HMP45 Group: E 16126HM Metallized membrane filter, 0.5 μm, ø 18.5 mm Use with: HMP35 Group: E 16126HM HM46717 8 9 10 11 HM47329 Probe cap, ø 18.5 mm (protective cap) Use with: HMT100 HM47329 12 Output units 13 Option for module slot 1 14 Stand Alone - Not Interchangeable: HM46780 Stainless steel filter, 38 μm, ø 20 mm Use with: DMP246CS - External 19858HM Membrane filter tube set (5 pcs) HMP42 aprobe, 0.2 μm, ø 4mm Steel grid for the HMP42 probe, 1 mm, ø 4 mm Option for module slot 2 15 Cable bushings 16 Transmitter installation 17 19867HM 1 2 3 4 5 6 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 1 A 0 Transmitter type HMT331 1 Wall probe fixed Cable length A with short cable Probe holder plate recommended in selection 16 8 No additional temperature probe 0 Parameters RH+T A RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B Display No display 0 Graphic display with keypad 1 Power supply 10...35 VDC , 24 VAC (HMT300PWS) 0 Galvanic isolation for outputs 10...35 VDC, 24 VAC (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V + Serial interface RS232 or optional communication module Analog output signals No 3rd analog output for Ch1 , Ch2 and Ch3 RH (0...100%RH) RH=relative humidity T (range: see below) T=temperature Td (-20...100°C) (-4...+212 °F) Td=dewpoint Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature a=absolute humidity a (0...600g/m3) (0...262 gr/ft3) Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature x=mixing ratio x (0...500g/kg d.a) (0...3500gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) h=enthalpy ppm (0…5000) (0…5000) ppm=parts per million pw=water vapor pressure pw (0…1000 hPa) (0…14.5psi) pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A if not needed Analog output range No temperature output (-40...+140°F) for temperature -40...+60°C (-4...+140°F) Note: -20...+60°C - Choose option A, if no (+32...+140°F) 0...+60°C T output is desired Special :_______________________ Humidity sensor type 18 Sensor protection 19 20 No probe installation kit Operating manual language PC Accessories HM46780 21 22 23 Calibration For future use 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1 $360 $320 $80 $200 $210 $60 1 2 3 4 5 B C D E F G H J K L M N X B C D E F G H J K L M N X Metric Non-metric No module Relay output (Relay-1) RS-485 serial interface (galvanically isolated) (RS485-1) LAN (Ethernet) interface + 2 m cable (RJ45) Not with universal AC power WLAN (Wireless Ethernet) interface + antenna with short cable probe only Data logger module No module Relay output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data logger module Not possible if the data logger module has already been chosen in item 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) 8-pole connector with 5 m cable (not possible with universal AC power option) (212142) (212416) 8-pole counter connector equipped with screw terminals (not possible with universal AC power option) Standard wall mounting Adapter plate (for replacing the HMP230's) (214829) Pole installation kit (215108) DIN rail kit (215094) Probe holder plate Recommended with short cable probe (226252) General purpose HUMICAP180 Chemical purge HUMICAP180C General purpose and high chemical concentrations HUMICAP180R Chemical purge HUMICAP180RC PPS plastic grid & stainless steel netting (DRW010281SP) PPS plastic grid (DRW010276SP) Sintered stainless steel filter (HM47280SP) A B C D E F G H J K L M N X A B F K X 1 2 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 A B C D $60 $60 0 1 2 4 5 $90 $100 $90 $90 1 4 A C $60 $60 A B C A No manual English No Service cable for PC, RS232 MI70LINK software for Windows® with RS232 service cable Service cable for PC, USB with software driver MI70LINK software for Windows® with USB service cable ISO9001 compliant calibration with NIST traceable certificate Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. (M210566EN) (19446ZZ) (215005) (219685) (219916) A B A B C D E $40 $60 $90 $90 A 1 TOTAL QTY TOTAL VALUE Example of order code with typical settings: HMT330 1 A 0 A 1 0 1 B C A B 2 0 0 A 0 A A A B A A 160 PRICE $1,120 1 161 HMT333 Humidity and Temperature Transmitter HMT334 Humidity and Temperature Transmitter For general use 1 2 3 4 5 6 7 8 9 10 11 For pressurized processes 1 2 3 3 E F G 4 5 6 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1 PRICE $1,170 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 Transmitter type HMT333 Cable length 2 m cable +80 °C 5 m cable +80 °C 10 m cable +80 °C 2 m cable +120 °C 5 m cable +120 °C 10 m cable +120 °C No additional temperature probe 0 Parameters RH+T A RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B Display No display 0 Graphic display with keypad 1 Power supply 10...35 VDC , 24 VAC (HMT300PWS) Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) Universal AC -power (100....240 VAC) (Power-1) Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V + Serial interface RS232 or optional communication module Analog output signals No 3rd analog output for Ch1 , Ch2 and Ch3 RH (0... 100%RH) RH=relative humidity T (range: see below) T=temperature Td (-20...100°C) (-4...+212 °F) Td=dewpoint Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature a=absolute humidity a (0...600g/m3) (0...262 gr/ft3) Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature x=mixing ratio x (0...500g/kg d.a) (0...3500gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) h=enthalpy ppm (0…5000) (0…5000) ppm=parts per million pw=water vapor pressure pw (0…1000 hPa) (0…14.5psi) pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A if not needed Analog output range No temperature output (-40...+176°F) for temperature -40...+80°C -40…+120 °C (-40…+248 °F) Note: Choose Option A, Other: Specify range:____________________ $150 $300 $220 $360 $540 Output units 13 Option for module slot 1 14 15 16 17 18 19 20 21 22 23 Option for module slot 2 Cable bushings Transmitter installation Humidity sensor type Sensor protection Installation kit for probe Operating manual language PC Accessories Calibration For future use Metric Non-metric No module Relay output RS-485 serial interface (galvanically isolated) Not with universal AC power LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logger module No module Relay output 3rd Analog output Choose also analog output signal for Ch3 Data logger module Not possible if the data logger module has already been chosen in item 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) Conduit fitting for wire conduit (NPT1/2") 8-pole connector with 5m cable (not possible with Universal AC power option) 8-pole counter connector equipped with screw terminals (not possible with Universal AC power option) Standard wall mounting Adapter plate (for replacing the HMP230's) Pole installation kit Pole installation kit with rain shield DIN rail kit General purpose Chemical purge General purpose and high chemical concentrations Chemical purge PPS plastic grid & stainless steel netting PPS plastic grid Sintered stainless steel filter No kit Duct installation kit Cable gland AGRO No manual English No Service cable for PC, RS232 MI70LINK software for Windows® with RS232 service cable Service cable for PC, USB with software driver MI70LINK software for Windows® with USB service cable ISO9001 compliant calibration with NIST traceable certificate 5 6 $320 0 1 2 3 9 $80 $200 $210 $60 7 1 2 3 4 5 B C D E F G H J K L M N X B C D E F G H J K L M N X A B C D E F G H J K L M N X 8 9 10 11 A C D X 1 2 3 4 5 6 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 4 0 HMT334 Transmitter type 4 Cable length 2 m cable H 5 m cable J 10 m cable K No additional temperature probe 0 Parameters RH+T A RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B Display No display 0 Graphic display with keypad 1 Power supply 10...35 VDC , 24 VAC (HMT300PWS) 0 Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V + Serial interface RS232 or optional communication module Analog output signals No 3rd analog output for Ch1 , Ch2 and Ch3 RH (0... 100%RH) RH=relative humidity T (range: see below) T=temperature Td (-20...100°C) (-4...+212 °F) Td=dewpoint Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature a=absolute humidity a (0...600g/m3) (0...262 gr/ft3) Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature x=mixing ratio x (0...500g/kg d.a) (0...3500gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) h=enthalpy ppm (0…5000) (0…5000) ppm=parts per million pw=water vapor pressure pw (0…1000 hPa) (0…14.5psi) pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A, if not needed Analog output range No temperature output (-40...+356°F) for temperature -40...+180°C Note: Choose Option A, Other: Specify range:____________________ 12 Output units 13 Option for module slot 1 1 2 0 1 2 4 5 6 (Relay-1) (RS485-1) $180 $160 $260 $320 $350 0 1 3 6 (Relay-1) (AOUT-1) (214728SP) (214780SP) (212142) (212416) $180 $160 $350 A B C D (214829) (215108) (215109) (215094) HUMICAP180 HUMICAP180C HUMICAP180R HUMICAP180RC (DRW010281SP) (DRW010276SP) (HM47280SP) (M210566EN) Cable bushings Note: The Universal AC power not connected Transmitter installation $60 $60 0 1 2 3 4 $90 $100 $110 $90 1 4 A C 17 Humidity sensor type 18 Sensor protection 19 Installation kit for probe Operating manual language PC Accessories $60 $60 A B C 20 $80 $50 21 $40 $60 $90 $90 22 23 A B A 1 TOTAL QTY TOTAL VALUE Example of order code with typical settings: HMT330 3 E 0 A 0 0 1 B C A C 2 0 0 A 0 A A A B A A Order Code DTR502B 15 Option for module slot 2 through 8 pole connector. A B C D E (19446ZZ) (215005) (219685) (219916) 14 16 A C D (210697) (HMP247CG) Additional Accessories: Description Outdoor Solar Radiatioin Shield 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1 PRICE $2,240 $160 $370 $360 $320 $80 $200 $210 $60 1 2 3 4 5 B C D E F G H J K L M N X B C D E F G H J K L M N X A B C D E F G H J K L M N X A E X if no T output is desired Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 162 3 4 $360 if no T output is desired 12 1 2 Calibration For future use Metric Non-metric No module Relay output (Relay-1) RS-485 serial interface (galvanically isolated) (RS485-1) Not with universal AC power LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logger module No module Relay output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data logger module Not possible if the data logger module has already been chosen in item 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) (212142) 8 pole connector with 5 m cable (212416) 8 pole connector supplied with screw terminals Standard wall mounting (214829) Adapter plate (for replacing the HMP230's) (215108) Pole installation kit DIN rail kit (215094) General purpose HUMICAP180 Chemical purge HUMICAP180C General purpose and high chemical concentrations HUMICAP180R Chemical purge HUMICAP180RC PPS plastic grid & stainless steel netting (DRW010281SP) PPS plastic grid (DRW010276SP) Sintered stainless steel filter (HM47280SP) Stainless steel grid (HM47453SP) Fitting body M22 x 1,5 (17223) Fitting body NPT 1/2" (17225) No manual (M210566EN) English No Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB with software driver MI70LINK software for Windows® with USB service cable (219916) ISO9001 compliant calibration with NIST traceable certificate 1 2 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 A B C D $60 $60 0 1 2 4 $90 $100 $90 1 4 A C $60 $60 A B C D E F A B A B C D E A 1 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings: HMT330 4 H 0 A 0 0 1 B C A E 2 $40 $60 $90 $90 0 0 A 0 A C F B A A 1 1 PRICE $310 163 1 2 3 4 5 6 7 8 9 10 11 HMT335 Humidity and Temperature Transmitter HMT337 Humidity and Temperature Transmitter For high temperatures For small spaces, high temperatures 1 2 3 4 5 6 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 5 0 HMT335 Transmitter type 5 Cable length 2 m cable L 5 m cable M 10 m cable N No additional temperature probe 0 Parameters RH+T A RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B Display No display 0 Graphic display with keypad 1 Power supply 10...35 VDC , 24 VAC (HMT300PWS) 0 Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V + Serial interface RS232 or optional communication module Analog output signals No 3rd analog output for Ch1 , Ch2 and Ch3 RH (0... 100%RH) RH=relative humidity T (range: see below) T=temperature Td (-20...100°C) (-4...+212 °F) Td=dewpoint Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature a=absolute humidity a (0...600g/m3) (0...262 gr/ft3) Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature x=mixing ratio x (0...500g/kg d.a) (0...3500gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) h=enthalpy ppm (0…5000) (0…5000) ppm=parts per million pw=water vapor pressure pw (0…1000 hPa) (0…14.5psi) pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A, if not needed Analog output range No temperature output (-40...+356°F) for temperature -40...+180°C Note: Choose Option A, Other: Specify range:____________________ 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1 PRICE $1,640 1 2 $160 $370 3 4 $360 5 $320 6 $80 $200 $210 $60 7 1 2 3 4 5 B C D E F G H J K L M N X B C D E F G H J K L M N X A B C D E F G H J K L M N X 8 9 10 11 A E X 13 14 15 16 17 18 19 20 21 22 23 Output units Metric Non-metric Option for module slot 1 No module Relay output (Relay-1) RS-485 serial interface (galvanically isolated) (RS485-1) Not with universal AC power LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logger module Option for module slot 2 No module Relay output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data logger module Not possible if the data logger module has already been chosen in item 11 Cable bushings Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Note: The Universal AC Conduit fitting for wire conduit (NPT1/2") (214780SP) power not connected 8 pole connector with 5 m cable (212142) through 8 pole connector. 8 pole connector supplied with screw terminals (212416) Transmitter installation Standard wall mounting (214829) Adapter plate (for replacing the HMP230's) (215108) Pole installation kit DIN rail kit (215094) Humidity sensor type General purpose HUMICAP180 Chemical purge HUMICAP180C General purpose and high chemical concentrations HUMICAP180R Chemical purge HUMICAP180RC Sensor protection in probe PPS plastic grid & stainless steel netting (recommended choice) (DRW010281SP) PPS plastic grid (DRW010276SP) Sintered stainless steel filter (HM47280SP) Stainless steel grid (HM47453SP) Installation kit No kit for probe Mounting flange (210696) Operating manual No manual (M210566EN) language English No PC Accessories Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB with software driver MI70LINK software for Windows® with USB service cable (219916) Calibration ISO9001 compliant calibration with NIST traceable certificate For future use Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1 1 2 0 1 2 4 5 6 12 Output units 13 Option for module slot 1 $180 $160 $260 $320 $350 14 0 1 3 6 Option for module slot 2 $180 $160 $350 15 A B C D Cable bushings Note: The Universal AC power not connected $60 $60 through 8 pole connector. 16 0 1 2 4 Transmitter installation $90 $100 $90 1 4 A C $60 17 Humidity sensor type $60 A B C D A G $60 18 Sensor protection 19 Installation kit for probe A B A B C D E $40 $60 $90 $90 20 21 A Operating manual language PC Accessories 1 TOTAL QTY TOTAL VALUE Example of order code with typical settings: HMT330 5 L 0 A 0 0 1 B C A E 2 0 0 A 0 A A A B A A $160 $370 $360 $320 $80 $200 $210 $60 1 2 3 4 5 B C D E F G H J K L M N X B C D E F G H J K L M N X 22 23 Calibration For future use Metric Non-metric No module Relay output (Relay-1) RS-485 serial interface (galvanically isolated) (RS485-1) LAN (Ethernet) interface + 2 m cable (RJ45) Not with universal AC power WLAN (Wireless Ethernet) interface + antenna Data logger No module Relay output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data logger module Not possible if the data logger module has already been chosen in item 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) (212142) 8 pole connector with 5 m cable (212416) 8 pole connector supplied with screw terminals Standard wall mounting (214829) Adapter plate (for replacing the HMP230's) (215108) Pole installation kit (215109) Pole installation kit with rain shield DIN rail kit (215094) General purpose HUMICAP180 Chemical purge default HUMICAP180C General purpose and high chemical concentrations HUMICAP180R Chemical purge HUMICAP180RC PPS plastic grid & stainless steel netting (DRW010281SP) PPS plastic grid (DRW010276SP) Sintered stainless steel filter (HM47280SP) Stainless steel grid (HM47453SP) No kit Cable gland AGRO (HMP247CG) Duct installation kit (210697) Swagelok NPT 1/2" (SWG12NPT12) Swagelok ISO 3/8" (SWG12ISO38) Swagelok ISO 1/2" (SWG12ISO12) No manual (M210566EN) English No Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB with software driver MI70LINK software for Windows® with USB service cable (219916) ISO9001 compliant calibration with NIST traceable certificate 1 Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. A B C D E F G H J K L M N X A E X 1 2 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 A B C D $60 $60 0 1 2 3 4 $90 $100 $110 $90 1 4 A C $60 $60 A B C D A D C K L Y $60 $80 $60 $60 $60 A B A B C D E $40 $60 $90 $90 A 1 TOTAL QTY TOTAL VALUE Example of order code with typical settings: HMT330 7 S 0 A 0 0 1 B C A E 2 0 0 A 0 A A A B A A 164 PRICE $1,640 if no T output is desired if no T output is desired 12 1 2 3 4 5 6 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 7 0 HMT337 Transmitter type 7 S Cable length 2 m cable T 5 m cable U 10 m cable Additional temperature No probe 0 probe Parameters RH+T A RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B Display No display 0 Graphic display with keypad 1 Power supply 10...35 VDC, 24 VAC (HMT300PWS) 0 Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V + Serial interface RS232 or optional communication module Analog output signals No 3rd analog output for Ch1 , Ch2 and Ch3 RH (0... 100%RH) RH=relative humidity T (range : see below) T=temperature Td (-20...100°C) (-4...+212 °F) Td=dewpoint Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature a=absolute humidity a (0...600g/m3) (0...262 gr/ft3) Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature x=mixing ratio x (0...500g/kg d.a) (0...3500gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) h=enthalpy ppm (0…5000) (0…5000) ppm=parts per million pw=water vapor pressure pw (0…1000 hPa) (0…14.5psi) pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A, if not needed Analog output range No temperature output (-40...+356°F) for temperature -40...+180°C Note: Choose Option A, Other: Specify range:____________________ 1 165 1 2 3 4 5 6 7 8 9 10 11 HMT337 Humidity and Temperature Transmitter with warmed probe HMT338 Humidity and Temperature Transmitter For high humidities For pressurized pipelines 1 2 3 4 5 6 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 7 HMT337 Transmitter type 7 S Cable length 2 m cable T dew point probe 5 m cable U 10 m cable Additional temperature No probe 0 probe 2 m cable 1 5 m cable 2 10 m cable 3 Parameters Td+Tdf+x (dew point probe only) C RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT D Display No display 0 Graphic display with keypad 1 Power supply 10...35 VDC , 24 VAC (HMT300PWS) 0 Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V + Serial interface RS232 or optional communication module Analog output signals No 3rd analog output for Ch1 , Ch2 and Ch3 RH (0... 100%RH) RH=relative humidity T (range: see below) T=temperature Td (-20...100°C) (-4...+212 °F) Td=dewpoint Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature a=absolute humidity a (0...600g/m3) (0...262 gr/ft3) Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature x=mixing ratio x (0...500g/kg d.a) (0...3500gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) h=enthalpy ppm (0…5000) (0…5000) ppm=parts per million pw=water vapor pressure pw (0…1000 hPa) (0…14.5psi) pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A, if not needed Analog output range No temperature output (-40...+356°F) for temperature -40...+180°C Note: Choose Option A, Other: Specify range:____________________ 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1 PRICE $2,480 1 2 $160 $370 $160 $180 $220 3 4 5 $320 6 $80 $200 $210 $60 7 1 2 3 4 5 B C D E F G H J K L M N X B C D E F G H J K L M N X A B C D E F G H J K L M N X 8 9 10 11 A E X Output units 13 Option for module slot 1 14 15 16 17 Option for module slot 2 Cable bushings Transmitter installation Humidity sensor type 18 Sensor protection 19 Installation kit for probe 20 21 22 23 Operating manual language PC Accessories Calibration For future use Metric 1 Non-metric 2 No module 0 Relay output (Relay-1) 1 RS-485 serial interface (galvanically isolated) (RS485-1) 2 LAN (Ethernet) interface + 2 m cable (RJ45) 4 Not with universal AC power WLAN (Wireless Ethernet) interface + antenna 5 Data logger module 6 No module 0 Relay output (Relay-1) 1 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) 3 Data logger module Not possible if the data logger module has already been chosen in item 11 6 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) 8-pole connector with 5m cable (not possible with Universal AC power option) (212142) (212416) 8-pole counter connector equipped with screw terminals (not possible with Universal AC power option) Standard wall mounting (214829) Adapter plate (for replacing the HMP230's) (215108) Pole installation kit (215109) Pole installation kit with rain shield DIN rail kit (215094) Composite sensor HUMICAP180C Composite sensor with chemical purge HUMICAP180C Compsite sensor HUMICAP180RC HUMICAP180RC Compsite sensor with chemical purge HUMICAP180RC Composite sensor for fuel cell applications PPS plastic grid & stainless steel netting (DRW010281SP) Sintered stainless steel filter (HM47280SP) Stainless steel grid (HM47453SP) (214848) Membrane SST filter for fuel cell applications No kit Duct installation kit (RH) (210697) Swagelok NPT 1/2" (RH) (SWG12NPT12) Swagelok ISO 3/8" (RH) (SWG12ISO38) Duct installation kit (RH + T probes) (210697 & 215003) Swagelok NPT 1/2" + Swagelok NPT 1/8" (RH + T) (SWG6NPT18 & SWG12NPT12) Swagelok ISO 3/8" + Swagelok ISO 3/8" (RH + T) (SWG6ISO18 & SWG12ISO18) (SWG12ISO12) Swagelok ISO 1/2" No manual (M210566EN) English No Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB with software driver (219916) MI70LINK software for Windows® with USB service cable ISO9001 compliant calibration with NIST traceable certificate Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 12 Output units 13 Option for module slot 1 $180 $160 $260 $320 $350 14 Option for module slot 2 $180 $160 $350 A B C D 15 Cable bushings 16 Transmitter installation $60 $60 0 1 2 3 4 $90 $100 $110 $90 5 6 D E F A C D F A C K L P Q R Y $80 $60 $60 $160 $120 $120 $60 17 A B C D E $40 $60 $90 $90 A 1 TOTAL QTY TOTAL VALUE Humidity sensor type 18 Sensor protection 19 Installation kit for probe 20 Operating manual language PC Accessories 21 22 23 A B Example of order code with typical settings: HMT330 7 S 1 D 0 0 1 B C A E 2 0 0 A 0 D A A B A A 166 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1 PRICE $1,980 $160 $370 $120 $260 $460 $360 $320 $80 $200 $210 $60 B C D E F G H J K L M N X B C D E F G H J K L M N X A B C D E F G H J K L M N X A E X if no T output is desired if no T output is desired 12 1 2 3 4 5 6 7 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330 8 0 Transmitter type HMT338 8 Cable length 2 m cable for 232 mm probe V 5 m cable for 232 mm probe W 10 m cable for 232 mm probe X 2 m cable for 454 mm probe 1 5 m cable for 454 mm probe 2 10 m cable for 454 mm probe 3 No additional temperature probe 0 Parameters RH+T A RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B Display No display 0 Graphic display with keypad 1 Power supply 10...35 VDC , 24 VAC 0 (HMT300PWS) Galvanic isolation for outputs 10...35 VDC , 24 VAC (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog Output Signal 4... 20 mA 1 for Ch1&Ch2(&Ch3) 0... 20 mA 2 0... 1 V 3 0... 5 V 4 0... 10 V 5 + Serial interface RS232 or optional communication module Analog output signals No 3rd analog output for Ch1 , Ch2 and Ch3 RH (0... 100%RH) RH=relative humidity T (range: see below) T=temperature Td (-20...100°C) (-4...+212 °F) Td=dewpoint Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature a (0...600g/m3) (0...262 gr/ft3) a=absolute humidity Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature x (0...500g/kg d.a) (0...3500gr/lb) x=mixing ratio h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) h=enthalpy ppm (0…5000) (0…5000) ppm=parts per million pw (0…1000 hPa) (0…14.5psi) pw=water vapor pressure pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A, if not needed Analog output range No temperature output for temperature -40...+180°C (-40...+356°F) Note: Choose Option A, Other: Specify range:____________________ Calibration For future use Metric 1 Non-metric 2 No module 0 Relay output (Relay-1) 1 RS-485 serial interface (galvanically isolated) (RS485-1) 2 LAN (Ethernet) interface + 2 m cable (RJ45) 4 Not with universal AC power WLAN (Wireless Ethernet) interface + antenna 5 Data logger module 6 No module 0 Relay output (Relay-1) 1 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) 3 Data logger module Not possible if the data logger module has already been chosen in item 11 6 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) 8-pole connector with 5m cable (not possible with Universal AC power option) (212142) (212416) 8-pole counter connector equipped with screw terminals (not possible with Universal AC power option) Standard wall mounting (214829) Adapter plate (for replacing the HMP230's) (215108) Pole installation kit DIN rail kit (215094) General purpose HUMICAP180 Chemical purge HUMICAP180C General purpose and high chemical concentrations HUMICAP180R Chemical purge HUMICAP180RC PPS plastic grid & stainless steel netting (DRW010281SP) PPS plastic grid (DRW010276SP) Sintered stainless steel filter (HM47280SP) Stainless steel grid (HM47453SP) Ball valve set (ISO 1/2") (DRW212076 + BALLVALVE-1) Pressure fitting NPT 1/2" (212810SP) Pressure fitting ISO 1/2" (DRW212076SP) No manual English (M210566EN) No PC Accessories Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB with software driver MI70LINK software for Windows® with USB service cable (219916) ISO9001 compliant calibration with NIST traceable certificate Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. $180 $160 $260 $320 $350 $180 $160 $350 A B C D $60 $60 0 1 2 4 $90 $100 $90 1 4 A C $60 $60 A B C D M N V $80 A B A B C D E A 1 TOTAL QTY TOTAL VALUE Example of order code with typical settings: HMT330 8 V 0 A 0 0 1 B C A E 2 0 0 A 0 A C N B A A Accessories: Description Order Code Sample cell (no fittings) DMT242SC Sample cell (with Swagelok connectors) DMT242SC2 $40 $60 $90 $90 1 PRICE $80 $100 1 167 Vaisala Meteorological Installation Kit for HMT330 Transmitters 1 2 3 4 5 Vaisala Meteorological Installation Kit Support bar & shield for warmed Td probe 1 2 3 4 5 HMT330MIK No support bar & shield for warmed Td probe Support bar, transmitter mounting plate & shield for warmed Td probe No support bar or radiation shield Support bar and radiation shield for Support bar with DTR502 shield for T probe additional T probe or for Support bar with DTR13 shield for T probe non-warmed RH or Td probe Support bar with DTR502 shield for non-warmed RH or Td probe Support bar with DTR13 shield for non-warmed RH or Td probe No mounting plate Support bar mounting plate Pole mounting plate for support bar/bars Additional transmitter mounting plate No additional transmitter mounting plate Transmitter mounting plate for support bar assembly Transmitter mounting plate for pole assembly Static Pressure Head No Static Pressure Head Static Pressure Head SPH10 Selections in bold are included in the prices of the basic versions. Selections in italic have an additional cost Shaded sections indicate typical selections. HMP155 Humidity and Temperature Probe PRICE 0 1 $580 A B C D E $580 $920 $580 $920 0 1 1 2 3 4 $120 A B C 0 1 TOTAL QTY TOTAL VALUE $110 $110 5 6 $270 7 8 Example of order code with typical settings: HMT330MIK 1 B 1 A 1 9 10 11 12 13 14 15 with voltage or RS485 output for temperature Vaisala HUMICAP® Humidity and Temperature Probe 2 x voltage output (RS485 for service use) Probe type RS485 serial output Signal output selection RS485 serial output (only for probe type E) 0…1 V output 0…5 V output 0…10 V output Analog output signal for CH1 None (RS485 output used) T (-40…+60°C) T (-40…+140°F) Choose option A, if No T output is desired, or output is RS485 T (-80…+60°C) T (-112…+140°F) None (RS485 output used) Analog output signal for CH2 (0…100%RH) RH Choose option A if output is RS485 Td (-60…+60°C) T (-76…+140°F) Tdf (-60…+60°C) T (-76…+140°F) Tw (0…+60°C) T (+32…+140°F) x (0…200g/kg d.a) (0…1400 gr/lb) Units Metric Non Metric Humidity Sensor Type General purpose HUMICAP180R Composite sensor HUMICAP180RC Gereral purpose HUMICAP180 Composite sensor HUMICAP180C Heating options None See(*) Note below Warmed probe (only with composite sensor) Warmed probe with Xheat (only with composite sensor) Chemical purge None Periodical (only with composite sensor) Start-up (only with composite sensor) Both periodical & start-up (only with composite sensor) Sensor protection Sintered Teflon filter Probe cable length No cable (no counter connector) 3.5 meter (with 8 pin M12 female connector) 10 meter (with 8 pin M12 female connector) 30 meter (with 8 pin M12 female connector) Additional Temperature probe None Additional T-probe with 2 m cable Calibration At room temperature PC-Accessories None PC connection cable (USB) MI70 connection cable PC connection cable (USB) & MI70 connection cable Installation accessories None Installation kit to Stevenson screen Additional T-probe installation part to DTR502 Additional T-probe installation part to DTR13 (For production use only) (*) NOTE: If warmed probe is chosen and additional temperature sensor is not used output signal for Ch1 must be 'None' and for Ch2 only Td, Tdf or x output can be selected. 168 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A 1 A A E PRICE $640 1 2 3 4 A G J A B C D E F 1 2 1 2 3 4 RH&T outputs only with Additional Temperature probe RH&T outputs only with Additional Temperature probe $60 $60 A B C $280 $280 0 1 2 3 A 0 1 2 3 $30 $50 $80 A B $160 1 A B C D Item: 221040 Item: 221801 Item: 222303 $90 $60 $150 0 1 2 3 Item: 221321 Item: 221072 Item: 221069 $95 $60 $80 A Example of order code with typical settings: Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Acessories and Spare Parts: HMP155 HMP155 A 2 G B 2 1 A 0 A 1 A 1 A 0 A Description: Connection cable 3.5 m - 8-pin M12 Connection cable 10 m - 8-pin M12 Connection cable 30 m - 8-pin M12 Sintered Teflon filter + O-ring Protection Set for Calibration Buttons Solar shield for humidity probe Solar shield for additional temperature probe Order Code: 220496 220497 220498 219452SP 221318 DTR503A DTR502B PRICE $30 $50 $80 $50 $15 $310 $310 169 HMT361 Humidity and Temperature Transmitter 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 with resistive 4-wire output for temperature Vaisala HUMICAP® Humidity and Temperature Probe Voltage output for RH (RS485 for service use), 4-wire Pt100 output for Temperature Probe type Signal output selection 0…1 V output 0…5 V output 0…10 V output Analog output signal for CH1 None (4-wire PT100 output used) (0…100%RH) Analog output signal for CH2 RH Units Metric Non Metric HUMICAP180R Humidity Sensor Type General purpose HUMICAP180 Gereral purpose Heating options None Chemical purge None Sensor protection Sintered Teflon filter Probe cable length No cable (no counter connector) 3.5 meter (with 8 pin M12 female connector) 10 meter (with 8 pin M12 female connector) 30 meter (with 8 pin M12 female connector) Additional Temperature probe None Calibration At room temperature PC-Accessories None PC connection cable (USB) Item: 221040 MI70 connection cable Item: 221801 PC connection cable (USB) & MI70 connection cable Item: 222303 Installation accessories None Installation kit to Stevenson screen Item: 221321 (For production use only) Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Acessories and Spare Parts: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B A 0 A A 1 A HMP155 D D 2 3 4 A B 1 2 1 3 A 0 A 0 1 2 3 A 1 A B C D 0 1 A For wall mounting 1 PRICE $600 1 2 3 4 $30 $50 $80 $100 $60 $160 $95 5 6 7 Example of order code with typical settings: HMP155 D 2 A B 2 1 A 0 A 1 A 1 A 0 A 8 Description: Connection cable 3.5 m - 8-pin M12 Connection cable 10 m - 8-pin M12 Connection cable 30 m - 8-pin M12 Sintered Teflon filter + O-ring Protection Set for Calibration Buttons Solar shield for humidity probe Order Code: 220496 220497 220498 219452SP 221318 DTR503A PRICE $30 $50 $80 $50 $15 $310 9 10 11 12 13 14 15 16 2 3 4 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 1 Transmitter type HMT361 1 RH+T A Parameters RH+T+Td+a+Tw+x D Display No display 1 Display on transmitter cover 2 Signal output 2 analog output channels (Ch1 + Ch24... 20 mA 2 Parameter and scaling for No analog output analog output (Ch1 & Ch2) RH (0... 100%RH) T (choose range in next section) Td (-40…60°C) (-40... 140°F) a (0... 160g/m3) (0...70gr/ft3) Tw (0…60°C) (+32...+140°F) x (0...160g/kg d.a) (0…1120gr/lb) Special: Define quantity for: CH1:____________CH2:________________ Define scale for: CH1:____________CH2:________________ NOTE: Transmitter unit HMP155 Humidity and Temperature Probe 5 6 7 8 9 10 11 12 13 14 15 16 A PRICE $2,120 $2,660 $120 B C D E F G X A B C D E F G X - Td, a, Tw and x are only avalable with parameter selection D Ch1 - If only one analog output has been chosen, choose A for Ch2 Ch2 Analog output range -40...+60°C (-40...+140°F) A for temperature -20...+60°C (-4...+140°F) B - If no temperature output is desired, choo0...+60°C (+32...+140°F) C Special X Output units Metric 1 Non-metric 2 Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A Conduit fitting NPT1/2" (for wire conduits) B Cable gland M20x1.5 for cable diameters 10 ... 15 mm C Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2 Factory Mutual (USA) 4 CSA (Canada) 5 TIIS (Japan) 7 User's guide No manual A English B Probe and cable length HMP361 max +60°C A Sensor type HUMICAP 180 1 HUMICAP 180L2 2 HUMICAP 180R 5 Reserved for future option A Sensor protection PPS plastic grid & stainless steel netting (recommended choi DRW0101281SP 1 PPS plastic grid DRW0101276SP 2 Sintered stainless steel filter HM47280SP 3 Stainless steel grid filter HM47453SP 4 Reserved for future option 0 TOTAL Selections in bold are included in the prices of the basic versions. QTY Selections in italic are available at an extra price. TOTAL VALUE Shaded sections indicate typical selections. Example of order code with typical settings: HMT360 1 A 2 2 B C A 2 A 4 B A 5 A 1 0 RH = Relative Humidity a = Absolute Humidity g/m3 T = Temperature x = Mixing Ratio g/Kg Td = Dewpoint TemperaTw = Wet Bulb Temperature NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360 manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance. Accessories and Spare Parts : Description Stahl Zener Barrier (Stahl # 9001/51-280-091-141) (active barrier that requires active input) Vyniker enclosure (enclosure holds 2 barriers) 170 Order Code: 210664 210665 PRICE $190/channel $90 each 171 HMT363 Humidity and Temperature Transmitter HMT364 Humidity and Temperature Transmitter For general use For high pressurized processes 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Transmitter unit 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 A PRICE $2,160 $2,710 3 $120 4 B C H J K L X A B C H J K L X - Td, a, Tw and x are only avalable with parameter selection D Ch1 - If only one analog output has been chosen, choose A for Ch2 Ch2 Analog output range -20...+80°C (-4...+176°F) D for temperature -20...+120°C (-4...+248°F) E -40...+80°C (-40...+176°F) F - If no temperature output is desired, choo-40...+120°C (-40...+248°F) G 0...+100°C (+32...+ 212°F) H Special X Output units Metric 1 Non-metric 2 Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A Conduit fitting NPT1/2" (for wire conduits) B Cable gland M20x1.5 for cable diameters 10 ... 15 mm C Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2 Factory Mutual (USA) 4 CSA (Canada) 5 TIIS (Japan) 7 User's guide No manual A English B Probe and cable length 2 m cable max 80°C 1 5 m cable max 80°C 2 10 m cable max 80°C 3 2 m cable max 120°C B 5 m cable max 120°C C 10 m cable max 120°C D Sensor type HUMICAP 180 1 HUMICAP 180L2 2 HUMICAP 180R 5 Reserved for future option A Sensor protection PPS plastic grid & stainless steel netting (recommended choi DRW0101281SP 1 PPS plastic grid DRW0101276SP 2 Sintered stainless steel filter HM47280SP 3 Stainless steel grid filter HM47453SP 4 Probe installation accessories None 0 Duct installation kit B TOTAL Selections in bold are included in the prices of the basic versions. QTY Selections in italic are available at an extra price. TOTAL VALUE Shaded sections indicate typical selections. Example of order code with typical settings: HMT360 3 A 2 2 B C D 2 A 4 B B 5 A 1 B RH = Relative Humidity a = Absolute Humidity g/m3 T = Temperature x = Mixing Ratio g/Kg Td = Dewpoint TemperaTw = Wet Bulb Temperature 5 6 7 8 9 10 $150 $300 $220 $360 $540 $80 Accessories and Spare Parts : Description Stahl Zener Barrier (Stahl # 9001/51-280-091-141) (active barrier that requires active input) Vyniker enclosure (enclosure holds 2 barriers) Order Code: 210664 210665 11 12 13 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PRICE A $3,270 $3,810 $120 B C H J K L X A B C H J K L X - Td, a, Tw and x are only avalable with parameter selection D Ch1 - If only one analog output has been chosen, choose A for Ch2 Ch2 (-4...+176°F) Analog output range -20...+80°C for temperature (-4...+248°F) -20...+120°C (-40...+176°F) -40...+80°C - If no temperature output is desired, choo-40...+120°C (-40...+248°F) (+32...+ 212°F) 0...+100°C (-4...+356°F) -20...+180°C (-40...+356°F) -40...+180 °C (+32...+356°F) 0...+180°C Special Output units Metric Non-metric Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm (for wire conduits) Conduit fitting NPT1/2" Cable gland M20x1.5 for cable diameters 10 ... 15 mm Ex certification and issuer ATEX 100a 94/9/EC (PTB) Factory Mutual (USA) CSA (Canada) TIIS (Japan) User's guide No manual English Probe and cable length 2 m cable 5 m cable 10 m cable Sensor type HUMICAP 180 HUMICAP 180L2 HUMICAP 180R D E F G H J K L X 1 2 A B C 2 4 5 7 A B E F G $160 $370 1 2 5 A 14 15 Sensor protection 16 Probe installation accessories PPS plastic grid & stainless steel netting (recommended choic DRW0101281SP DRW0101276SP PPS plastic grid HM47280SP Sintered stainless steel filter HM47453SP Stainless steel grid filter None Fitting body M22x1.5 male Fitting body NPT 1/2" male 1 2 3 4 0 K G TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings: RH = Relative Humidity a = Absolute Humidity g/m3 HMT360 4 A 2 2 B C D 2 A 4 B E 5 A 3 G T = Temperature x = Mixing Ratio g/Kg Td = Dewpoint TemperaTw = Wet Bulb Temperature NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360 manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance. 172 1 2 2 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 4 Transmitter type HMT364 4 RH+T A Parameters RH+T+Td+a+Tw+x D Display No display 1 Display on transmitter cover 2 Signal Output 2 analog output channels (Ch1 + Ch24... 20 mA 2 Parameter and scaling for No analog output analog output (Ch1 & Ch2) RH (0... 100%RH) T (choose range in next section) (-40...212°F) Td (-40...100°C) (0...218.5gr/ft3) a (0...500g/m3) (+32...+212°F) Tw (0...100°C) x (0...500g/kg d.a) (0...3500gr/lb) Special: Define quantity for: CH1:____________CH2:________________ Define scale for: CH1:____________CH2:________________ NOTE: Transmitter unit 1 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 3 Transmitter type HMT363 3 RH+T A Parameters RH+T+Td+a+Tw+x D Display No display 1 Display on transmitter cover 2 Signal Output 2 analog output channels (Ch1 + Ch2) 4... 20 mA 2 Parameter and scaling for No analog output analog output (Ch1 & Ch2) RH (0... 100%RH) T (choose range in next section) Td (-40...100°C) (-40...212°F) a (0...500g/m3) (0...218.5gr/ft3) Tw (0...100°C) (+32...+212°F) x (0...500g/kg d.a) (0...3500gr/lb) Special: Define quantity for: CH1:____________CH2:________________ Define scale for: CH1:____________CH2:________________ NOTE: PRICE $190/channel $90 each NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360 manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance. Accessories and Spare Parts : Description Stahl Zener Barrier (Stahl # 9001/51-280-091-141) (active barrier that requires active input) Vyniker enclosure (enclosure holds 2 barriers) Order Code: 210664 210665 PRICE $190/channel $90 each 173 HMT365 Humidity and Temperature Transmitter HMT367 Humidity and Temperature Transmitter For high temperatures For high humidities 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Transmitter unit 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 PRICE A $2,840 $3,370 $120 B C H J K L X Transmitter type Parameters 3 Display 4 Signal Output Parameter and scaling for analog output (Ch1 & Ch2) A B C H J K L X - Td, a, Tw and x are only avalable with parameter selection D Ch1 - If only one analog output has been chosen, choose A for Ch2 Ch2 Analog output range -20...+80°C (-4...+176°F) for temperature -20...+120°C (-4...+248°F) -40...+80°C (-40...+176°F) - If no temperature output is desired, choo-40...+120°C (-40...+248°F) 0...+100°C (+32...+ 212°F) -20...+180°C (-4...+356°F) -40...+180 °C (-40...+356°F) 0...+180°C (+32...+356°F) Special Output units Metric Non-metric Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm Conduit fitting NPT1/2" (for wire conduits) Cable gland M20x1.5 for cable diameters 10 ... 15 mm Ex certification and issuer ATEX 100a 94/9/EC (PTB) Factory Mutual (USA) CSA (Canada) TIIS (Japan) User's guide No manual English Probe and cable length 2 m cable 5 m cable 10 m cable Sensor type HUMICAP 180 HUMICAP 180L2 HUMICAP 180R 5 6 7 D E F G H J K L X 8 9 1 2 A B C 10 2 4 5 7 11 12 A B H J K 13 $160 $370 1 2 5 14 15 A Sensor protection Probe installation accessories PPS plastic grid & stainless steel netting (recommended choi DRW0101281SP PPS plastic grid DRW0101276SP Sintered stainless steel filter HM47280SP Stainless steel grid filter HM47453SP None Mounting flange 1 2 3 4 0 D TOTAL QTY TOTAL VALUE 16 $60 Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings: HMT360 5 A 2 2 B C D 2 A 4 B H 5 A 1 D RH = Relative Humidity a = Absolute Humidity g/m3 T = Temperature x = Mixing Ratio g/Kg Td = Dewpoint TemperaTw = Wet Bulb Temperature NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360 manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance. Accessories and Spare Parts : Description Stahl Zener Barrier (Stahl # 9001/51-280-091-141) (active barrier that requires active input) Vyniker enclosure (enclosure holds 2 barriers) 174 Vaisala HUMICAP® Humidity and Temperature Transmitter 1 2 Order Code: 210664 210665 PRICE $190/channel $90 each Transmitter unit 1 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 5 Transmitter type HMT365 5 RH+T A Parameters RH+T+Td+a+Tw+x D Display No display 1 Display on transmitter cover 2 Signal Output 2 analog output channels (Ch1 + Ch24... 20 mA 2 Parameter and scaling for No analog output analog output (Ch1 & Ch2) RH (0... 100%RH) T (choose range in next section) Td (-40...100°C) (-40...212°F) a (0...500g/m3) (0...218.5gr/ft3) Tw (0...100°C) (+32...+212°F) x (0...500g/kg d.a) (0...3500gr/lb) Special: Define quantity for: CH1:____________CH2:________________ Define scale for: CH1:____________CH2:________________ NOTE: Special: Define quantity for: Define scale for: 2 3 4 5 6 7 8 9 HMT360 7 HMT367 7 RH+T A RH+T+Td+a+Tw+x D No display 1 Display on transmitter cover 2 2 analog output channels (Ch1 + Ch24... 20 mA 2 No analog output RH (0... 100%RH) T (choose range in next section) Td (-40...100°C) (-40...212°F) a (0...500g/m3) (0...218.5gr/ft3) Tw (0...100°C) (+32...+212°F) x (0...500g/kg d.a) (0...3500gr/lb) CH1:____________CH2:________________ CH1:____________CH2:________________ 10 11 12 13 14 15 16 A PRICE $2,840 $3,370 $120 B C H J K L X A B C H J K L X NOTE: - Td, a, Tw and x are only avalable with parameter selection D Ch1 - If only one analog output has been chosen, choose A for Ch2 Ch2 Analog output range -20...+80°C (-4...+176°F) D for temperature -20...+120°C (-4...+248°F) E -40...+80°C (-40...+176°F) F - If no temperature output is desired, choo-40...+120°C (-40...+248°F) G 0...+100°C (+32...+ 212°F) H -20...+180°C (-4...+356°F) J -40...+180 °C (-40...+356°F) K 0...+180°C (+32...+356°F) L Special X Output units Metric 1 Non-metric 2 Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A Conduit fitting NPT1/2" (for wire conduits) B Cable gland M20x1.5 for cable diameters 10 ... 15 mm C Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2 Factory Mutual (USA) 4 CSA (Canada) 5 TIIS (Japan) 7 User's guide No manual A English B Probe and cable length 2 m cable V 5 m cable W 10 m cable X Sensor type HUMICAP 180 1 HUMICAP 180L2 2 HUMICAP 180R 5 Reserved for future option A 1 Sensor protection PPS plastic grid & stainless steel netting (recommended choic DRW0101281SP PPS plastic grid DRW0101276SP 2 Sintered stainless steel filter HM47280SP 3 Stainless steel grid filter HM47453SP 4 Probe installation accessories None 0 Duct installation kit B Cable Gland AGRO J Swagelok NPT 1/2" L Swagelok ISO 3/8" M TOTAL Selections in bold are included in the prices of the basic versions. QTY Selections in italic are available at an extra price. TOTAL VALUE Shaded sections indicate typical selections. Example of order code with typical settings: RH = Relative Humidity a = Absolute Humidity g/m3 HMT360 7 A 2 2 B C D 2 A 4 B V 5 A 1 L T = Temperature x = Mixing Ratio g/Kg Td = Dewpoint TemperaTw = Wet Bulb Temperature $160 $370 $80 $60 $60 $60 NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360 manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance. Accessories and Spare Parts : Description Stahl Zener Barrier (Stahl # 9001/51-280-091-141) (active barrier that requires active input) Vyniker enclosure (enclosure holds 2 barriers) Order Code: 210664 210665 PRICE $190/channel $90 each 175 HMT368F Moisture and Temperature Transmitter for Oil HMT368 Humidity and Temperature Transmitter For pressurized pipelines 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 A PRICE $3,020 $3,570 $120 B C H J K L X A B C H J K L X Analog output range for temperature - If no temperature output is desired, choose A Order Code: 210664 210665 8 Output units 9 Interface cable connection 10 Ex certification and issuer $160 $370 $120 $260 $460 11 User's guide 12 Probe and cable length 13 14 15 16 3 Sensor type -40...+60°C -20...+60°C 0...+60°C -20...+80°C -20...+120°C -40...+80°C -40...+120°C 0...+100°C -20...+180°C -40...+180 °C 0...+180°C Special 4 5 6 7 8 9 10 11 12 13 14 15 2 A 4 16 PRICE $3,440 $120 2 C M X Ch1 Ch2 (-40...+140°F) (-4...+140°F) (+32...+140°F) (-4...+176°F) (-4...+248°F) (-40...+176°F) (-40...+248°F) (+32...+ 212°F) (-4...+356°F) (-40...+356°F) (+32...+356°F) Scale (in °C or F) Metric Non-metric Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm (for wire conduits) Conduit fitting NPT1/2" Cable gland M20x1.5 for cable diameters 10 ... 15 mm ATEX 100a 94/9/EC (PTB) Factory Mutual (USA) CSA (Canada) TIIS (Japan) None English German French Finnish Swedish Japanese 2m (6.6 ft) 226 mm probe (9") 5 m (16.4 ft) 226 mm probe (9") 10 m (32.8 ft) 226 mm probe (9") 2m (6.6 ft) 448 mm probe (18") 5 m (16.4 ft) 448 mm probe (18") 10 m (32.8 ft) 448 mm probe (18") Special sensor for fluids A C M X A B C D E F G H J K L X 1 2 A B C 2 4 5 7 A B C D E G J L M N P Q R $160 $360 $80 $240 $440 2 A Sensor protection Probe installation accessories Stainless steel grid filter Ball valve set for installation into pipeline Fitting Body NPT1/2 Fitting Body ISO1/2 HM47453SP 4 E H N TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. $80 $80 Example of order code with typical settings: HMT360 8 F 2 2 M C D 2 Spare parts & Accessories Stahl Zener Barrier Vyniker enclosure (holds 2 barriers) NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360 manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance. 176 4 5 6 7 - Td, a, Tw and x are only avalable with parameter selection D Ch1 - If only one analog output has been chosen, choose A for Ch2 Ch2 Analog output range -20...+80°C (-4...+176°F) D for temperature -20...+120°C (-4...+248°F) E -40...+80°C (-40...+176°F) F (-40...+248°F) G - If no temperature output is desired, choo-40...+120°C 0...+100°C (+32...+ 212°F) H -20...+180°C (-4...+356°F) J -40...+180 °C (-40...+356°F) K 0...+180°C (+32...+356°F) L Special X Output units Metric 1 Non-metric 2 Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A Conduit fitting NPT1/2" (for wire conduits) B Cable gland M20x1.5 for cable diameters 10 ... 15 mm C Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2 Factory Mutual (USA) 4 CSA (Canada) 5 TIIS (Japan) 7 User's guide No manual A English B Probe and cable length 2 m cable 226 mm probe, max 180°C L 5 m cable 226 mm probe, max 180°C M 10 m cable 226 mm probe, max 180°C N 2 m cable 448 mm probe, max 180°C P 5 m cable 448 mm probe, max 180°C Q 10 m cable 448 mm probe, max 180°C R Sensor type HUMICAP 180 1 HUMICAP 180L2 2 HUMICAP 180R 5 Reserved for future option A Sensor protection PPS plastic grid & stainless steel netting (recommended choic DRW0101281SP 1 PPS plastic grid DRW0101276SP 2 Sintered stainless steel filter HM47280SP 3 Stainless steel grid filter HM47453SP 4 Probe installation accessories Ball valve set E Fitting Body NPT1/2 H Fitting Body ISO1/2 N TOTAL Selections in bold are included in the prices of the basic versions. QTY Selections in italic are available at an extra price. TOTAL VALUE Shaded sections indicate typical selections. Example of order code with typical settings: RH = Relative Humidity a = Absolute Humidity g/m3 HMT360 8 A 2 2 B C D 2 A 4 B L 5 A 3 E T = Temperature x = Mixing Ratio g/Kg Td = Dewpoint TemperaTw = Wet Bulb Temperature Accessories and Spare Parts : Description Stahl Zener Barrier (Stahl # 9001/51-280-091-141) (active barrier that requires active input) Vyniker enclosure (enclosure holds 2 barriers) 1 2 3 2 Vaisala HUMICAP® Moisture and Temperature Transmitter for Oil HMT360 8 F HMT368 for pressurized pipelines 8 Transmitter type aw+T F Parameters Display No display 1 Display on transmitter cover 2 Number of analog outputs 2 analog output channels (Ch1 + Ch2) 4... 20 mA Parameter and scaling for No analog output (Ch2) analog output (Ch1 & Ch2) Temperature aw (0...1) Define quantity for: CH1:________________CH2:________________ Special: Define scale for: CH1:________________CH2:________________ Transmitter unit 2 Transmitter unit 1 2 Probe 1 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 8 Transmitter type HMT368 8 Parameters RH+T A RH+T+Td+a+Tw+x D Display no display 1 display on transmitter cover 2 Signal Output 2 analog output channels (Ch1 + Ch24... 20 mA 2 Parameter and scaling for No analog output analog output (Ch1 & Ch2) RH (0... 100%RH) Temperature (choose range in next section) Td (-40...100°C) (-40...212°F) a (0...500g/m3) (0...218.5gr/ft3) Tw (0...100°C) (+32...+212°F) x (0...500g/kg d.a) (0...3500gr/lb) Special: Define quantity for: CH1:____________CH2:________________ Define scale for: CH1:____________CH2:________________ NOTE: PRICE $190/channel Order Code: 210664 210665 A 4 B M 2 A 4 E PRICE $190/channel $90 NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360 manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance. $90 each 177 1 2 3 4 5 6 HMT100 Series Humidity and Temperature Transmitter Vaisala INTERCAP® Humidity and Temperature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Vaisala HUMICAP® Humidity and Temperature Transmitter HMT100 A 0 0 A Transmitter type Wall mount/fixed probe Remote probe with 3 m cable B Remote probe with 5 m cable C Remote probe with 10 m cable D Remote probe with 10 m cable + 10 m extension E No display 0 Display Display *) 1 Output channels ***) RH or Td only 1 Two output parameters 2 2-wire loop-powered A Signal output ***) 4... 20 mA 3-wire 0... 1 V B 3-wire 0... 5 V C 3-wire 0... 10 V D Define scale: 3-wire 0… ______________ V **) X SPECIAL Probe HMP60 Parameter for Ch1 ***) Parameter for Ch2 ***) 8 9 10 11 12 13 No T Define scale SPECIAL 7 RH Td Define quantity Output units ***) Humidity sensor type Sensor protection Transmitter installation Installation kit for probe Cable bushings Operating manual language 0…100 %RH -20...+80°C __________ Scale (-4...+176°F) _____________ Vaisala HUMICAP® Humidity and Temperature Probe 1 Output signals $100 $100 2 Measured parameter for channel 1 1 6 X 3 Measured parameter for channel 2 0 2 3 4 5 7 X -40...+60°C (-40...+140°F) -20...+80°C (-4...+176°F) 0...+60°C (+32...+140°F) -40...+80°C (-40...+176°F) 0...+50°C ('32...+122°F) _______________________ Metric Non-metric General purpose Plastic grid Plastic grid with filter Sintered stainless steel filter Wall mounting plate (plastic) Wall mounting plate (Aluminum) Outdoor installation kit (Weather shield) No accessories Duct installation kit DTR502B with probe installation kit Cable gland for 2…6 mm cable Stainless steel liquid tight PG9 Conduit fitting NPT 1/2" No manual English PRICE $430 $580 $600 $620 $710 4 Sensor protection 5 Accessories 1 2 3 A B C $30 $110 1 2 3 D Scaling for 4..20 mA converter (channel 1 only) I RS485 R None - RS485 0 RH 1 T (-40 ... +60°C) 2 Td (-40 ... +60°C) 3 None - RS485 or current interface 0 RH 1 T (-40 ... +60°C) 2 Td (-40 ... +60°C) 3 Plastic grid with filter (DRW010525) A Plastic grid (DRW010522) B Stainless steel sintered filter (HM46670SP) C No accessories No cable 9 Loop power converter (18350SP) 1 A 1 (HMP50Z032) 2 $10 60 °C cable 3 m (HMP50Z30A) 3 $20 180 °C FEP cable 3m (226902) F A Multilingual quick guide B No converter 0 (ui-converter -1) 1 $20 $310 $45 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Example of order code with typical settings: HMP60 A 1 2 A 0 A 1 B 0 Example of order code with typical settings: HMT100 A 0 2 A 1 2 2 A 2 A 1 A B 0 0 HMP100 Probe for HMT100 Series HMP100 A A (DRW010522) (DRW010525) (HM46670SP) $60 No user guide 0 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. $45 0 60 °C cable 0.3 m 4...20 mA loop power converter A B (M210701EN-A) *) backlight not available with 4…20 mA output **) value must be between 0…10 V ***) These options can not be modified in the field. 1 2 3 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings: HMP100 A 2 178 1 ...5V 7 Probe cable length 0 HUMICAP®180 Plastic grid Plastic grid with filter Stainless steel sintered filter C A B C 14 15 Vaisala HUMICAP® Probe Humidity sensor Sensor protection B 0...5 V Intercap 8 User guide $240 A 0...2.5 V 6 Humidity sensor A (215619) (HMT100DTR502B) 0...1 V Pair of plastic nuts 1 2 HUMICAP180 (DRW010522) (DRW010525) (HM46670SP) (GM45160) (DRW010712) (215109) PRICE HMP60 PRICE $280 Acessories and Spare Parts: Description: Order Code: Probe mounting flange 226061 PRICE $51 Mounting bracket with lid 225979 $85 Probe mounting clamp set (10 pcs) 226067 $102 USB cable 219690 $100 Plastic nuts 18350SP (enclosure for 4-20mA loop power converter) $10 179 HMI41Set Humidity & Temperature Indicator and Probe Vaisala HUMICAP® Humidity and Temperature 1 Probe HMP110 Vaisala HUMICAP® Humidity and Temperature Probe 1 Output signals 2 Measured parameter for channel 1 PRICE HMP110 0...1 V $480 A 0...2.5 V B 0...5 V C 1 ...5V D Scaling for 4..20 mA converter (channel 1 only) I RS485 R None - RS485 0 RH 3 Measured parameter for channel 2 4 Sensor protection 5 Accessories (-40 ... +80°C) 5 Td (-40 ... +80°C) 6 None - RS485 or current interface 0 Selections in bold are included in the prices of the basic versions. RH 1 Selections in italic are available at an extra price. Shaded sections indicate typical selections. T (-40 ... +80°C) 5 Td (-40 ... +80°C) 6 Plastic grid with filter (DRW010525) (DRW010522) B Stainless steel sintered filter (HM46670SP) C No accessories Pair of plastic nuts Humicap180R 7 Probe cable length No cable 9 Loop power converter $45 0 (18350SP) 1 C 1 60 °C cable 0.3 m (HMP50Z032) 2 $10 60 °C cable 3 m (HMP50Z30A) 3 $20 80 °C cable 1.5 m (225777) 4 $35 80 °C cable 3 m (225229) 5 $45 180 °C FEP cable 3m (226902) F $60 No user guide A Multilingual quick guide B No converter 4...20 mA loop power converter 2 3 HMI41SET PRICE $860 $1,120 $980 $1,120 $760 $780 A B C D E F (MI70CASE2) (210614) 1 3 5 $160 $60 A B TOTAL QTY TOTAL VALUE Example of order code with typical settings: HMI41SET D 5 B A Plastic grid 6 Humidity sensor 8 User guide 1 T Vaisala HUMICAP® Humidity and Temperature Indicator 1 Probe HMP41 HMP42 HMP45 HMP46 HMP44 HMP44L 2 Carrying Case for HMI41 no case and probe(s) Aluminum case for HMP41/42/45/46 Rigid plastic case for HMP41/42/45/46 3 Manual no manual English 0 (ui - converter -1) 1 $45 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Accessories and Spare Parts: Descripton: Membrane filter tube set (5 pcs) for the HMP42 probe Steel grid for the HMP42 probe Serial interface cable for HMI41 Indicator only Calibration adapter for HMP42 probe Rubber sleeve set (10 pcs) for HMP42 probe Connection Cables for: HMD/W60/70 HMP230 Series HMD/W20/30 HMT330, HMT360 and HMT100 with over voltage-barrier HMT360 Series Order Code: 19858HM 19867HM 19446ZZ HMI41 HM37067 19809HM PRICE $25 $45 $40 $460 $20 $20 19116ZZ 19164ZZ 19165ZZ 25917ZZ 25905ZZ $30 $30 $30 $30 $30 HMI41 Spare Probes Only: HMP41 HMP42 HMP45 HMP46 HMP44 HMP44L $400 $660 $520 $660 $300 $320 Example of order code with typical settings: HMP110 A Acessories and Spare Parts: 1 5 A 0 C 1 B 0 Description: Order Code: Probe mounting flange 226061 PRICE $51 Mounting bracket with lid 225979 $85 Probe mounting clamp set (10 pcs) 226067 $102 USB cable 219690 $100 Plastic nuts 18350SP (enclosure for 4-20mA loop power converter) 180 $10 181 HMK15 Humidity Calibrator HM70 Hand-held Humidity and Temperature Meter ® Vaisala HUMICAP Hand-Held Humidity and Temperature Meter 1 Indicator type no indicator * rechargable with Euro AC-adapter rechargable with US AC-adapter alkaline batteries only 2 Indicator accessories no indicator accessories MI70LINK(software with RS232 cable) analog output-signal cable MI70LINKand analog output-signal cable MI70LINK software with USB cable 3 Probe type HMP75 HMP75B (chemical purge and sensor preheating) HMP76 HMP76B (chemical purge and sensor preheating) HMP77 HMP77B (chemical purge and sensor preheating) 4 Calibration at room temperature 5 Probe accessories no accessories probe holder for HMP76/76B** 6 Connection cable no connection cable connection cable to 60/70/140 series transmitters to a transmitter connection cable to HMP230 series connection cable to 20/30/130 series transmitters connection cable to HMT330 series / HMT100 7 Carrying case no carrying case carrying case for indicator and probe (HMP75/77/77B) carrying case for indicator and probe (HMP75/76/76B/77/77B)*** 8 Manual language no manual English * select item A, if only probe is ordered ** used in field calibration of duct 60/70 and 20/30 transmitters *** case for two probes (MI70USADAPTER + 26755) (18950 (4 pieces)) (MI70LINK) (27168ZZ) (MI70LINK + 27168ZZ) (219687) (HM36915) (HMA6070) (27159ZZ) (HMA2030) (211339) MI70CASE MI70CASE2 1 2 3 4 5 6 7 8 HM70 1 A B D K 0 1 2 3 4 A F B C D E 1 A B 0 1 2 3 4 A B C A B TOTAL QTY TOTAL VALUE $840 $840 $780 $60 $35 $95 $90 $690 $800 $840 $950 $1,020 $1,120 $25 $60 $60 $60 $60 $140 $200 Example of order code with typical settings: 2 3 4 5 6 7 8 2 3 4 5 6 7 8 9 HMK15 (19766HM) (19729HM) $550 A B $140 0 1 2 (19730HM) (19731HM) (19732HM) $40 $80 0 1 2 $40 $80 0 1 2 $40 $80 0 1 2 $40 $80 A B (19767HM) $20 0 1 (HM27032) (19728HM) (25130HM) $140 1 2 A B C TOTAL QTY TOTAL VALUE Shaded sectionss indicate typical selections. HM70 D 4 A 1 A 0 B B 182 1 Vaisala Humidity Calibrator Salt chamber no additional salt chamber an additional salt chamber LiCl salt no LiCl LiCl (11 %RH) for one chamber LiCl (11 %RH) for two chambers MgCl2 salt no MgCl2 MgCl2 (33%RH) for one chamber MgCl2 (33%RH) for two chambers NaCl salt no NaCl NaCl (75 %RH) for one chamber NaCl (75%RH) for two chambers K2SO4 salt no K2SO4 K2SO4 (97 %RH) for one chamber K2SO4 (97 %RH) for two chambers Ion exchanged water no water water for three chambers Carrying bag no bag carrying bag Thermometer with mercury with red capillary liquid Manual no manual English French Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Order Code: MI70USADAPTER 26755 1 9 Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Accessories and Spare Parts: Description: US Adapter Battery NiMH 4.8 for MI70 Probe Accessories: HMP75 Plastic PC grid filter Membrane filter Sintered bronze filter HMP76/77 Plastic PPS grid filter Sintered stainless steel filter Sintered bronze filter (HMP76 standard) PPS grid with SS netting (HMP77 standard) With Two Standard Chambers PRICE Example of order code with typical settings: HMK15 A 1 0 1 0 A PRICE $60 $30 6221 10159HM DRW212987SP $30 $30 $50 DRW010276SP HM47280SP $30 $50 DRW212987SP $50 DRW010281SP $30 Bulk Salt Accessories: Description Lithium Chloride (LiCI) Sodium Chloride (NaCI) Potassium Sulfate (K2 SO4) Order Code 5236 4102 2827 0 1 Size 250 g 1 kg 1 kg B PRICE $80 $40 $60 183 DMW19 Dewpoint Wall Transmitter DMT342 Dewpoint and Temperature Transmitter 1 Vaisala HUMICAP® Dewpoint Transmitter 1 0…1 V Analog output 0…5 V 4…20 mA 2 -20…+60 °C Td Dewpoint range -10 …+40 °C Td for analog output 0…+160 °F Td +30…+130 °F Td free scaling (specify): 3 User Guide No user guide Multilingual user guide 2 PRICE $630 DMW19 A B C 1 2 3 4 1 2 4 5 X __________________________ With Small Size Flanged Probe for use with sampling cell 3 5 6 7 A X Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings: DMW19 A 1 Vaisala DRYCAP® Dewpoint and Temperature Transmitter Transmitter type DMT342 Probe Cable lengths 2 m cable (6.6 ft) 5 m cable (16.4 ft) 10 m cable (32.8 ft) Measurement Dewpoint + PPM + Mixing ratio Parameters Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature Display No display Graphic Display with Keypad 10...35 VDC, 24 VAC Power Supply 10...35 VDC, 24 VAC with Galvanic Isolation for Outputs Universal AC -power (100....240 VAC) Universal AC -power (100....240 VAC) + US -power cord External US AC-adapter (for LAN/WLAN interface in USA) Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V Analog Output Scaling No 3rd analog output for Ch1&Ch2(&Ch3) Dewpoint (-80...+20 °C) ( -112...+68 °F) Dewpoint (-60...+20 °C) ( -76...+68 °F) Dewpoint (-50...+50 °C) ( -58...+122 °F) Temperautre (0...+80 °C) (+32...+176 °F) PPMv (0...1000 ppm) PPMw (0...1000 ppm) Mixing ratio (0...30g/kg d.a) (0...210gr/lbs) Relative humidity (0...100%) SPECIAL Define scale for 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 A 0 PRICE $2,570 $160 $370 $320 A B C D K $80 $200 $210 $60 1 2 3 4 5 only for channel 1 only for channel 1 Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) X B C D E G H J K B C D E A B C D E J J K K X X X Ch1:_____________ Ch2:_____________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A, if not needed 8 9 10 11 Operating Pressure 12 Output Units 13 Additional Option 14 1 2 3 4 5 DMT340 2 0 2 B C D 0 (for temperatures below 0° C) A (for temperatures above 0° C) B 0 1 (HMT300PWS) (DCDC-1) (Power-1) (Power-1 & 215991) Not IP65 2nd Additional Option 15 User Cable Connection 16 Transmitter Housing Installation 1 bar (abs) (14.5 psi abs) 3 bar (43.5) 5 bar (72.5) 7 bar (101.5) 9 bar (130.5) special ( max 50 bar / 725 psi )** (bar / psi)(abs) Metric units Non-metric units No Additional Option Alarm Relay Output (Relay-1) RS-485 Serial Interface with Galvanic Isolation (RS485-1) LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (wireless Ethernet) interface + antenna Data Logging Module No Additional Option Alarm Relay Output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data Logging Module Not possible if data logger has already been chosen in 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) Connector (M12, 8 pin) and Plug with 5m Black Cable (212142) Connector (M12, 8 pin) and Plug for User's Cable (212416) Wall Mounting Wall Mounting (for adapting to DMP248) (214829) Pipe/Pole Installation (215108) Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) DIN-Rail Installation (215094) DRYCAP® 180M Sintered stainless steel filter (HM47280SP) Stainless steel filter for vacuum (HM47453SP) No Accessories Sample Cell ( HMT302SC ) No manual English No PC Accessories MI70LINK software for Windows® with RS232 service cable (215005) MI70LINK software for Windows® with USB service cable (219916) Standard Calibration, with NIST traceable certificate 17 18 Dewpoint Sensor Sensor Protection 19 20 Probe Installation Accessories User's guide language 21 PC Accessories 22 23 Calibration For future use Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. ** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales 1 2 3 4 5 X A B 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 1 2 3 4 $60 $60 A B C D E $90 $100 $110 $90 1 A B 0 1 $80 A B 0 2 4 $60 $90 A 0 TOTAL QTY TOTAL VALUE Example of order code with typical settings: 2 B 0 B 1 A 1 B E A 1 B 0 0 1 A 1 A 1 B 0 A 0 DMT340 184 185 DMT344 Dewpoint and Temperature Transmitter DMT347 Dewpoint and Temperature Transmitter For Pressurized Processes 1 2 3 4 5 6 7 With Small Pressure-tight Probe Vaisala DRYCAP® Dewpoint and Temperature Transmitter Transmitter type DMT344 Probe Cable lengths 2 m cable (6.6 ft) 5 m cable (16.4 ft) 10 m cable (32.8 ft) Measurement Dewpoint + PPM + Mixing ratio Parameters Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature Display No display Graphic Display with Keypad Power Supply 10...35 VDC, 24 VAC 10...35 VDC, 24 VAC with Galvanic Isolation for Outputs Universal AC -power (100....240 VAC) Universal AC -power (100....240 VAC) + US -power cord External US AC-adapter (for LAN/WLAN interface in USA) Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V Analog Output Scaling No 3rd analog output for Ch1&Ch2(&Ch3) Dewpoint (-80...+20 °C) ( -112...+68 °F) Dewpoint (-60...+20 °C) ( -76...+68 °F) Dewpoint (-50...+50 °C) ( -58...+122 °F) Temperautre (0...+80 °C) (+32...+176 °F) PPMv (0...1000 ppm) PPMw (0...1000 ppm) Mixing ratio (0...30g/kg d.a) (0...210gr/lbs) Relative humidity (0...100%) SPECIAL 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 A 0 Define scale for 12 Output Units 13 Additional Option 14 2nd Additional Option 15 User Cable Connection 16 Transmitter Housing Installation 17 Dewpoint Sensor 18 Sensor Protection 19 Probe Installation Accessories 20 User's guide language 21 PC Accessories 22 Calibration 23 For future use PRICE $2,960 $160 $370 A B C D K $80 $200 $210 $60 1 2 3 4 5 only for channel 1 only for channel 1 B C D E G H J K B C D E A B C D E J J K K ** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales 6 7 SPECIAL 8 9 10 11 Operating Pressure 1 2 3 4 5 X 12 Output Units 13 Additional Option A B 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 1 2 3 4 14 2nd Additional Option 15 User Cable Connection 16 Transmitter Housing $60 $60 A B C D E $90 $100 $110 $90 1 Installation 17 Dewpoint Sensor 18 Sensor Protection 19 Probe Installation Accessories A B 20 User's guide language 2 3 21 PC Accessories A B 0 2 4 A 0 TOTAL QTY TOTAL VALUE Example of order code with typical settings: DMT340 4 H 0 B 1 A 1 B E A 1 B 0 0 1 A 1 A 3 B 0 A 0 $60 $90 1 2 3 4 5 7 0 7 S T U 0 (for temperatures below 0° C) A (for temperatures above 0° C) B 0 1 (HMT300PWS) (DCDC-1) (Power-1) (Power-1 & 215991) Not IP65 DMT340 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 A 0 22 Calibration 23 For future use PRICE $2,460 $160 $370 $320 A B C D K $80 $200 $210 $60 1 2 3 4 5 only for channel 1 only for channel 1 Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) Define scale for Channel 1 Channel 2 Channel 3, choose A, if not needed Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 3 4 X X X Ch1:_____________ Ch2:_____________ Optional Ch3:______________ 1 bar (abs) (14.5 psi abs) 3 bar (43.5) 5 bar (72.5) 7 bar (101.5) 9 bar (130.5) special ( max 50 bar / 725 psi )** (bar / psi)(abs) Metric units Non-metric units No Additional Option Alarm Relay Output (Relay-1) (RS485-1) RS-485 Serial Interface with Galvanic Isolation LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (wireless Ethernet) interface + antenna Data Logging Module No Additional Option Alarm Relay Output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data Logging Module Not possible in the data logger has already been chosen in item 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) (212142) Connector (M12, 8 pin) and Plug with 5m Black Cable (212416) Connector (M12, 8 pin) and Plug for User's Cable Wall Mounting Wall Mounting (for adapting to DMP248) (214829) Pipe/Pole Installation (215108) Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) DIN-Rail Installation (215094) DRYCAP® 180M Sintered stainless steel filter (HM47280SP) Stainless steel filter for vacuum (HM47453SP) FITTING BODY M22 x 1.5 (17223) FITTING BODY NPT1/2" (17225) No manual English No PC Accessories MI70LINK software for Windows® with RS232 service cable (215005) MI70LINK software for Windows® with USB service cable (219916) Standard Calibration, with NIST traceable certificate Vaisala DRYCAP® Dewpoint and Temperature Transmitter DMT340 2 m cable (6.6 ft) 5 m cable (16.4 ft) 10 m cable (32.8 ft) Measurement Dewpoint + PPM + Mixing ratio Parameters Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature Display No display Graphic Display with Keypad 10...35 VDC, 24 VAC Power Supply 10...35 VDC, 24 VAC with Galvanic Isolation for Outputs Universal AC -power (100....240 VAC) Universal AC -power (100....240 VAC) + US -power cord External US AC-adapter (for LAN/WLAN interface in USA) Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V Analog Output Scaling No 3rd analog output for Ch1&Ch2(&Ch3) Dewpoint (-80...+20 °C) ( -112...+68 °F) Dewpoint (-60...+20 °C) ( -76...+68 °F) Dewpoint (-50...+50 °C) ( -58...+122 °F) Temperautre (0...+80 °C) (+32...+176 °F) PPMv (0...1000 ppm) PPMw (0...1000 ppm) Mixing ratio (0...30g/kg d.a) (0...210gr/lbs) Relative humidity (0...100%) 1 Transmitter type 2 Probe Cable lengths 5 $320 Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) 8 9 10 11 Operating Pressure 186 1 2 3 4 5 DMT340 4 0 4 H J K 0 (for temperatures below 0° C) A (for temperatures above 0° C) B 0 1 (HMT300PWS) (DCDC-1) (Power-1) (Power-1 & 215991) Not IP65 B C D E G H J K B C D E A B C D E J J K K X X X Ch1:_____________ Ch2:_____________ Optional Ch3:______________ Channel 1 Channel 2 Channel 3, choose A, if not needed 1 bar (abs) (14.5 psi abs) 3 bar (43.5) 5 bar (72.5) 7 bar (101.5) 9 bar (130.5) special ( max 50 bar / 725 psi )** (bar / psi)(abs) Metric units Non-metric units No Additional Option Alarm Relay Output (Relay-1) RS-485 Serial Interface with Galvanic Isolation (RS485-1) LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (wireless Ethernet) interface + antenna Data Logger Module No Additional Option Alarm Relay Output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data Logger Module Not possible if the data logger module has already been chosen in item 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) Connector (M12, 8 pin) and Plug with 5m Black Cable (212142) Connector (M12, 8 pin) and Plug for User's Cable (212416) Wall Mounting Wall Mounting (for adapting to DMP248) (214829) Pipe/Pole Installation (215108) Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) DIN-Rail Installation (215094) DRYCAP® 180M Sintered stainless steel filter (HM47280SP) Stainless steel filter for vacuum (HM47453SP) Swagelok connector ISO 3/8" (SWG12ISO38) Swagelok connector NPT 1/2" (SWG12NPT12) SWG12ISO12 Swagelok connector ISO 1/2" No manual English No PC Accessories MI70LINK software for Windows® with RS232 service cable (215005) MI70LINK software for Windows® with USB service cable (219916) Standard Calibration, with NIST traceable certificate Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 1 2 3 4 5 X A B 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 1 2 3 4 $60 $60 A B C D E $90 $100 $110 $90 1 A B 4 5 K A B 0 2 4 $60 $90 A 0 TOTAL QTY TOTAL VALUE ** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales Example of order code with typical settings: DMT340 7 S 0 B 1 A 1 B E A 1 B 0 0 1 A 1 A 5 B 0 A 0 187 DMT345 Dewpoint Transmitter DMT348 Dewpoint and Temperature Transmitter For measurement in hot and dry processes For Pressurized Pipelines Vaisala DRYCAP® Dewpoint and Temperature Transmitter 1 Transmitter type DMT348 2 Probe Cable lengths 2 m cable (6.6 ft) for standard probe 5 m cable (16.4 ft) for standardp probe 10 m cable (32.8 ft) for standard probe 2 m cable (6.6 ft) for long probe 5 m cable (16.4 ft) for long probe 10 m cable (32.8 ft) for long probe 34 Measurement Dewpoint + PPM + Mixing ratio Parameters Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature 5 Display No display Graphic Display with Keypad 6 Power Supply 10...35 VDC, 24 VAC 10...35 VDC, 24 VAC with Galvanic Isolation for Outputs Universal AC -power (100....240 VAC) Universal AC -power (100....240 VAC) + US -power cord External US AC-adapter (for LAN/WLAN interface in USA) 7 Analog Output Signal 4... 20 mA for Ch1&Ch2(&Ch3) 0... 20 mA 0... 1 V 0... 5 V 0... 10 V Analog Output Scaling No 3rd analog output for Ch1&Ch2(&Ch3) Dewpoint (-80...+20 °C) ( -112...+68 °F) Dewpoint (-60...+20 °C) ( -76...+68 °F) Dewpoint (-50...+50 °C) ( -58...+122 °F) Temperautre (0...+80 °C) (+32...+176 °F) PPMv (0...1000 ppm) PPMw (0...1000 ppm) Mixing ratio (0...30g/kg d.a) (0...210gr/lbs) Relative humidity (0...100%) SPECIAL DMT340 1 8 8 2 3 0 4 5 8 9 10 11 Operating Pressure 12 Output Units 13 Additional Option 14 2nd Additional Option 15 User Cable Connection 16 Transmitter Housing Installation 17 Dewpoint Sensor 18 Sensor Protection 19 Probe Installation Accessories 20 User's guide language 21 PC Accessory 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 A 0 V W X 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PRICE $2,790 $160 $370 $120 $260 $460 0 (for temperatures below 0° C) (for temperatures above 0° C) A B 2 Probe cable length 3 - $320 A B C D K $80 $200 $210 $60 1 2 3 4 5 only for channel 1 only for channel 1 5 m cable (16.4 ft) M 10 m cable (32.8 ft) N 7 Analog output B C D E G H J K B C D E A B C D E J K J K X X X 0 1 10...35 VDC, 24 VAC with galvanic isolation for outputs (DCDC-1) Universal AC -power (100....240 VAC) (Power-1) C $200 Universal AC -power (100....240 VAC) + US -power cord (Power-1 & 215991) D $210 Ethernet US AC-adapter (for LAN/WLAN intrface in USA) 4... 20 mA A B Not IP65 $80 $60 K 1 0... 20 mA 2 0... 1 V 3 0... 5 V 4 0... 10 V 5 No 3rd analog output parameter and scaling for Ch1&Ch2 Dewpoint (0...+100 °C) (+32...+212 °F) 1 1 1 Mixing ratio (0...1000g/kg) (0...7000gr/lbs) 2 2 2 T (0...140 °C) (+32...284 °F) A 3 3 3 K K K Define parameter (unit) for Ch1:________________(_____) Ch2:_______________(_____) X X X Ch1:______________________ Ch2:______________________ 8 Channel 1 9 Channel 2 Channel 3, choose A, if not needed 11 Operating pressure 12 Output units 1 2 3 4 5 X $320 (HMT300PWS) 10 1 bar (abs) (14.5 psi abs) 3 bar (43.5) 5 bar (72.5) 7 bar (101.5) 9 bar (130.5) special ( max 50 bar / 725 psi )** (bar / psi)(abs) Metric units Non-metric units No Additional Option Alarm Relay Output (Relay-1) (RS485-1) RS-485 Serial Interface with Galvanic Isolation LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (wireless Ethernet) interface + antenna Data Logger Module No Additional Option Alarm Relay Output (Relay-1) 3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) Data Logger Module Not possible if data logger module has already been chosen in item 11 Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) Conduit fitting for wire conduit (NPT1/2") (214780SP) (212142) Connector (M12, 8 pin) and Plug with 5m Black Cable (212416) Connector (M12, 8 pin) and Plug for User's Cable Wall Mounting Wall Mounting (for adapting to DMP248) (214829) Pipe/Pole Installation (215108) Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) DIN-Rail Installation (215094) DRYCAP® 180M Sintered stainless steel filter (HM47280SP) Stainless steel filter for vacuum (HM47453SP) (ISOFITBODASP) Fitting body R 1/2" ISO with leak screw (DRW212076SP) Fitting body R 1/2" ISO ( no leak screw ) (NPTFITBODASP) Fitting body NPT1/2" ( no leak screw ) (THREADSETASP) Two Fitting Bodies: R 1/2" ISO with leak screw + NPT1/2" (DMT242SC) Sampling Cell (DMT242SC2) Sampling Cell with Swagelok connectors (DRW212076 + BALVALVE-1) Ball Valve Set for Pressurized Pipelines Flange for Duct Installation (DM240FA) No manual English No PC Accessories MI70LINK software for Windows® with RS232 service cable (215005) MI70LINK software for Windows® with USB service cable (219916) Standard Calibration, with NIST traceable certificate $370 10...35 VDC, 24 VAC Define scale for Channel 1 Channel 2 Channel 3, choose A, if not needed 1 ambient Metric units A Non-metric units 13 Additional feature A B 14 Additional feature 2 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 1 2 3 4 None (Relay-1) 1 $180 (RS485-1) 2 $160 6 $350 Data Logging Module None 15 Interface cable connection $90 $100 $110 $90 A B C D E F G H $25 $80 $100 $80 $80 A B 0 2 4 22 Calibration 23 For future use Selections in bold are included in the prices of the basic versions Selections in italic are available at an extra price. Shaded sections indicate typical selections. $60 90 A 0 TOTAL QTY TOTAL VALUE 0 Alarm Relay Output (Relay-1) 1 $180 3rd analog output (AOUT-1) 3 $160 4 $260 5 $320 WLAN (wireless ethernet) interface + antenna installation A B 0 Alarm Relay Output LAN (ethernet) interface + 2 m cable (RJ45) 16 Transmitter housing 1 B RS-485 Serial Interface with Galvanic Isolation Data Logging Module Cable gland (for 8...11 mm cable) (for 0.315...0.433 inch cable) Not possible if the data logger module has already been chosen in item 13 (214728SP) $350 1 Conduit fitting for wire conduit (NPT1/2") (214780SP) (212142) 3 $60 (212416) 4 $60 Wall Mounting 2 A Wall Mounting with Quick Installation or on Junction Boxes (214829) B $90 Pipe/Pole Installation (215108) C $100 Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) D $110 DIN-Rail Installation (215094) E 17 Sensor DRYCAP®180S 18 Sensor Protection Stainless steel sintered filter 19 Probe installation None 20 User's guide Flange None $90 2 (HM47280SP) (21069) A 0 7 $60 A English 21 PC accessories 6 Connector (M12, 8 pin) and Plug with 5m Black Cable Connector (M12, 8 pin) and Plug for User's Cable A B C D E PRICE B RH (0...100 %RH) Ch1:_____________ Ch2:_____________ Optional Ch3:______________ C $160 Analog output SPECIAL 2 A 0 Dewpoint + mixing ratio + RH+ T No display 6 Power supply 1 $3,140 L Graphical display with keypad 0 1 0 B 5 2 m cable (6.6 ft) - 5 Display (HMT300PWS) (DCDC-1) (Power-1) (Power-1 & 215991) Not IP65 DMT340 5 Vaisala DRYCAP® Dewpoint Transmitter DMT345 1 Transmitter type 4 Measurement parameters Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) Define scale for 6 K 0 None MI70LINK software for Windows® with RS232 service cable (215005) 2 MI70LINK software for Windows® with USB service cable (219916) 4 22 Calibration Standard Calibration with NIST traceable certificate 23 Service contract None Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. $60 $90 C 0 TOTAL QTY TOTAL VALUE Example of order code with typical settings: DMT340 5 L 0 B 1 A 1 1 3 A 1 B 0 0 1 A 2 A 0 K 0 C 0 ** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales Example of order code with typical settings DMT340 8 V 0 B 1 A 1 B 188 E A 1 B 0 0 1 A 1 A C B 0 A 0 189 DMT152 Dewpoint Transmitter DMT346 Dewpoint Transmitter 1 With passive cooling for very hot processes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 DMT340 Vaisala DRYCAP® Dewpoint Transmitter 1 Transmitter type DMT346 2 Probe cable length 3 - 6 0 K C PRICE 2 m cable (6.6 ft) P Q $160 10 m cable (32.8 ft) R $370 0 Dewpoint + mixing ratio (+ SSR + Ts)* 5 Display No display 2 3 K 0 Graphical display with keypad 1 $320 10...35 VDC, 24 VAC (HMT300PWS) 10...35 VDC, 24 VAC with galvanic isolation for outputs (DCDC-1) B $80 Universal AC -power (100....240 VAC) (Power-1) C $200 Universal AC -power (100....240 VAC) + US -power cord (Power-1 & 215991) D $210 External US AC-adapter (for LAN/WLAN interface in USA) 4... 20 mA Not IP65 K A 4 $60 1 0... 20 mA 2 0... 1 V 3 0... 5 V 4 0... 10 V 5 Analog output No 3rd analog output parameter and scaling for Ch1&Ch2& Ch3 Dewpoint (0...+100 °C) ( +32...+212 °F) 1 1 1 Mixing ratio (0...1000g/kg) (0...7000gr/lbs) 2 2 2 SPECIAL Define parameter (unit) for Ch1:________________(_____) Ch2:_______________(_____) Define scale for 1 $4,600 5 m cable (16.4 ft) 4 Measurement parameters 7 Analog output 2 D 6 6 - 6 Power supply 1 A 5 X X X Ch1:______________________ Ch2:______________________ 8 Channel 1 9 Channel 2 Channel 3, choose A, if not needed 10 11 Operating pressure 12 Output units 1 ambient Metric units A Non-metric units 13 Additional feature 14 Additional feature 2 0 Alarm Relay Output (Relay-1) 1 $180 RS-485 Serial Interface with Galvanic Isolation (RS485-1) 2 $160 LAN (ethernet) interface + 2 m cable (RJ45) 4 $260 WLAN (wireless ethernet) interface + antenna 5 $320 Data Logging Module None 6 16 Transmitter housing installation (Relay-1) 1 $180 3rd analog output: Choose also analog output parameter and scale for Ch3 (AOUT-1) 3 $160 Data Logging Module Cable gland (for 8...11 mm cable) 6 Not possible if the data logger module has already been chosen in item 13 (for 0.315...0.433 inch cable)(214728SP) (214780SP) 2 Connector (M12, 8 pin) and Plug with 5m Black Cable (212142) 3 Connector (M12, 8 pin) and Plug for User's Cable (212416) 4 Wall Mounting (214829) B $90 Pipe/Pole Installation (215108) C $100 Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) D $110 DIN-Rail Installation (215094) E Stainless steel sintered filter for cooling set (HM46780) 19 Probe installation accessories With cooling set None (DMP246CS) 6 A 0 2 MI70LINK software for Windows® with USB service cable (219916) 4 23 Service contract None $90 Stainless steel mesh filter None 2 m (6.6 ft) cable with snap-on connector 3 m (9.8 ft) shielded cable with threaded connector 10 m (32.8 ft) shielded cable with threaded connector None 2 m (6.6 ft) cable with snap-on connector 3 m (9.8 ft) shielded cable with threaded connector 10 m (32.8 ft) shielded cable with threaded connector None Sampling cell Sampling cell with swagelok 1/4" male connectors Sampling cell with quick connector and leak screw Two-pressure sampling cell Two-pressure sampling cell with venting coil DSC74C None Standard cardboard Plastic case None Multilingual quick guide Accessories: PRICE 217490 4 5 6 7 8 9 10 11 12 13 14 PRICE $1,510 $1,510 $1,510 A B C 1 2 A B C D E B C D E X Y F 1 2 High High High Level B C D E X Y F 1 2 High High High Level 1 2 0 1 X bar A (211598) (HMP50Z300SP) (HMP50Z1000SP) (211598) (HMP50Z300SP) (HMP50Z1000SP) 0 1 3 5 $10 $20 $60 0 1 3 5 $10 $20 $60 0 D E F G H (DMT242SC) (DMT242SC2) (DSC74) (DSC74B) (DSC74C) $80 $100 $100 $220 $340 A 1 2 $20 A X Total Total value Example of order code with typical settings: DMT152 B 1 D B E 2 0 A 1 0 0 A 1 X Example of order code with typical settings: DMT340 6 P 0 K 1 A 1 1 2 A 1 B 0 0 1 A 2 D 6 K 0 C 0 Mounting flange for cooling set 3 * Indicates when autocalibration or sensor purge are activated - measurement is not active TOTAL VALUE Spare Parts: 2 DMT152 Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. 0 TOTAL QTY Shaded sections indicate typical selections. * Sensor saturation rate (SSR) is a parameter describing the relative humidity at the sensor ( the margin to condense). Ts is the temperature at the sensor. These parameters do not give information on the humidity or $60 C Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. 11 Installation accessories ONLY for ISO1/2" thread 14 User' s guide K (215005) Standard Calibration with NIST traceable certificate 10 Cable for RS485 line and power supply (Port II) 12 Special features 13 Package D None MI70LINK software for Windows® with RS232 service cable 22 Calibration 8 Sensor Protection 9 Cable for analog outputs and power supply (Port I) $90 2 English 190 $60 Wall Mounting with Quick Installation or on Junction Boxes 18 Sensor Protection 7 $60 A DRYCAP®180S 21 PC accessories $350 1 Conduit fitting for wire conduit (NPT1/2") 17 Sensor 20 User's guide $350 0 Alarm Relay Output 15 Interface cable connection 6 B None Vaisala DRYCAP® Dewpoint Transmitter Mechanical connection ISO G1/2" thread NPT 1/2" thread UNF 3/4"-16 thread Measurement parameters Td/f, ppm Td/f, ppm and ppmw for SF6 gas Analog output Ch1 & Ch2 0...1 V + RS-485 as standard 0...5 V 0...10 V 4...20 mA 0...20 mA Td/f Analog output parameter -80...+20 °C -112...+68 °F or function Td/f -100...0 °C -148...+ 32 °F for Ch1 ppm 0...100 ppm ppm 0...500 ppm Td/f , free scale Define: Low ppm, free scale Define: Low ppmw for SF6, free scale Define: Low Parameter Alarm level on/off output Define: Autocalibration & purge on/off output* Td/f Analog output parameter -80...+20 °C -112...+68 °F or function Td/f -100...0 °C -148...+ 32 °F ppm for Ch2 0...100 ppm ppm 0...500 ppm Td/f , free scale Define: Low ppm, free scale Define: Low ppmw for SF6, free scale Define: Low Alarm level on/off output Define: Parameter Autocalibration & purge on/off output* Metric units (Celsius) Output units Non-metric units (Fahrenheit) Pressure setting for None - no ppm output ppm calculation Ambient 1 bara / 14,76 psia Special (max 50 bar abs) Define pressure: $300 Description Connection cable for MI70 indicator USB serial interface cable Sealing ring set ISO (copper, 3 pcs) Sealing ring set UNF (copper, 3 pcs) Stainless steel mesh filter 8 μm Loop-powered display 4…20mA/-80…20 °C Tdf, Nokeval 301 100...240 VAC external power supply Order Code: 219980 219690 221524 221563 220957 226476 POWER-1 PRICE $100 $100 $15 $15 $50 $250 $200 191 DMT242 Dewpoint Transmitter DM70 Hand-held Dewpoint Meter 1 2 3 4 5 6 7 Vaisala DRYCAP® Dewpoint Transmitter ® 1 Dewpoint range -80…+20 °C Td, DRYCAP 180M ® for analog output -60…+60 °C Td, DRYCAP 180M ® Free scaling Td, DRYCAP 180M DMT242 1 2 3 4 5 6 7 8 PRICE $1,310 A B X Define Td scale: ________ - ________ (°C) 1 2 ® -50...+50 °C Td, DRYCAP 180S (for refrigerator dryers) S Free scaling Td °C, DRYCAP®180S (for refrigerator dryers) Y Define Td scale: ________ - ________ (°C) 2 Analog Output Cable No cable - connector only 2m (6.6 ft) Connection cable with DMT242 valve connector 3 Pressure setting for optimized accuracy 4 Sensor protection 5 PC accessories 6 Installation accessories 7 User's guide 1 (221475SP) 2 10 m (33 ft) Connection cable with DMT242 valve connector (221476SP) 1 bar abs (14.5 psi abs) 3 bar abs (43.5 psi abs) 5 bar abs (72.5 psi abs) 7 bar abs (101.5 psi abs) Define value: _______ bar abs special (max 20 bar abs) Stainless steel sintered filter (37 um) Stainless steel filter for vacuum (below 0.5 bar abs) None Serial interface cable for service use, DMT242RS None Basic sampling cell (DMT242SC) Sampling cell, swagelok 1/4" male connectors (DMT242SC2) Sampling cell with quick connector and leak screw (DSC74) Two pressure sampling cell (DSC74B) Two pressure sampling cell with coil (DSC74C) NPT 1/2" adapter (210662) Duct installation flange (DM240FA) None English French 3 Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. 3 $40 $70 A B C D X 1 2 5 A B $50 0 1 2 3 4 5 6 9 $80 $100 $100 $220 $340 $25 $80 A B D TOTAL QTY TOTAL VALUE 192 Order Code 226476 7 8 PRICE A B D K $840 $840 $780 0 1 2 3 5 $60 $35 $95 $90 $1,630 $1,630 $2,410 A B C 0 1 2 3 4 5 6 $100 $1,560 $80 $100 $220 $340 A B C D E M $60 $60 $60 $60 $140 0 1 2 $140 $200 A B 1 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Example of order code with typical settings: DM70 D 5 B 0 A 1 B 1 Accessories and Spare Parts: DMT242 A 1 D 1 A 0 B Description Loop-powered display 4…20mA/-80…20 °C Tdf, Nokeval 301 6 * select item A, if only probe is ordered ** select item 0, if portable sampling system is selected Example of order code with typical settings: Accessories: 4 DM70 Vaisala DRYCAP® Hand-held Dewpoint Meter no indicator* Indicator type rechargable with Euro AC-adapter (MI70USADAPTER+26755) rechargable with US AC-adapter (18950 (4 pieces)) alkaline batteries only Indicator accessories no indicator accessories (MI70LINK) MI70Link (software with RS232 cable) (27168ZZ) analog output-signal cable MI70Link and analog output-signal cable (MI70LINK + 27168ZZ) MI70LINK software with USB cable (219687) Probe type DMP74A -40…+60 °C Td DMP74B -60…+20 °C Td DMP74C -50…+20 °C Td (for SF6 gas) Probe accessories no accessories sample cell (quick connect & leak screw) (DSC74) portable sampling system with case (DSS70A) sample cell (no fittings) (DMT242SC) sample cell (with swagelock connectors) (DMT242SC2) two-pressure sample cell (DSC74B) two-pressure sample cell with coil (DSC74C) Connection cable no connection cable (27160ZZ) to a transmitter connection cable to DMT242 transmitter connection cable to DMP248 transmitter (27159ZZ) (211917ZZ) connection cable to DMT142 transmitter (211339) connection cable to DMT340 transmitter connection cables to DMP248 & DMT242 & DMT142 & DMT340 Carrying case no carrying case** (MI70CASE) carrying case (Black ABS), for one probe (MI70CASE2) carrying case (Aluminium), for two probes Manual language No manual English Standard Special Features Price $250 Description 10m extension cable for probe SS sample cooling coil SS sintered filter 12mm diameter SS filter guard for vacuum applications US Adapter Battery NiMH 4.8 for MI70 Order Code 213107SP DMCOIL HM47280SP HM47453SP MI70USADAPTER 26755 PRICE $60 $120 $50 $50 $60 $30 193 1 2 3 4 5 6 7 8 9 10 MMT332 Moisture and Temperature Transmitter for Oil MMT337 Moisture and Temperature Transmitter for Oil for high pressure applications With Small Pressure-tight Probe 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Vaisala HUMICAP® Moisture and Temperature Transmitter MMT330 2 0 E 2 A 1 Transmitter type MMT332 2 Probe cable length 2 m cable B 5 m cable C 10 m cable D ----None 0 Measurement parameters aw+T E Display No display 0 Graphic LCD with backlight 1 Power supply 10...35 VDC, 24 VAC (HMT300PWS) 0 10...35 VDC, 24 VAC with Galvanic Isolation for Outputs (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US -power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog output 4... 20 mA 1 0... 20 mA 2 0... 1 V 3 0... 5 V 4 0... 10 V 5 Analog output None A parameter and scaling T (range: see below) C C C aw (0...1) for Ch1&Ch2(&Ch3) (0...1) P P P Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) SPECIAL X X X Define scale for Ch1:_____________ Ch2:____________ Optional Ch3:______________ PRICE $1,980 1 2 $160 $370 3 4 5 $320 6 $80 $200 $210 $60 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Vaisala HUMICAP® Moisture and Temperature Transmitter MMT330 7 0 E 2 A 1 MMT337 Transmitter type 7 S Probe cable length 2 m cable 5 m cable T 10 m cable U ----None 0 Measurement parameters aw+T E Display None 0 Graphic LCD with backlight 1 Power supply 10...35 VDC, 24 VAC (HMT300PWS) 0 10...35 VDC, 24 VAC with Galvanic Isolation for Outputs (DcDc-1) 1 Universal AC -power (100....240 VAC) (Power-1) 2 Universal AC -power (100....240 VAC) + US -power cord (Power-1 and 215991) 3 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 9 Analog output 4... 20 mA 1 0... 20 mA 2 0... 1 V 3 0... 5 V 4 0... 10 V 5 Analog output No 3rd analog output A parameter and scaling T (range: see below) C C C aw (0...1) for Ch1&Ch2(&Ch3) (0...1) P P P Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) SPECIAL X X X Define scale for Ch1:_____________ Ch2:____________ Optional Ch3:______________ Analog output range for temperature NOTE: - Choose option A, if no T output is desired 12 13 14 15 16 17 18 SPECIAL Output units Additional feature Additional feature 2 Interface cable connection Transmitter housing installation Sensor Sensor protection 19 20 Probe installation access. User's guide 21 PC Accessories 22 23 Calibration ----- None (-40...+140°F) -40...+60°C (-40...+176°F) -40...+80°C (-40...+248°F) -40...+120°C (-40...+356°F) -40...+180°C (-4...+140°F) -20...+60°C (-4...+176°F) -20...+80°C (-4...+248°F) -20...+120°C (-4...+356°F) -20...+180°C (+32...+140°F) 0...+60°C (+32...+ 212°F) 0...+100°C (+32...248°F) 0...+120°C (+32...356°F) 0...+180°C (-76...+140°F) -60...60 °C __________________°C / ___________________ F Metric Non-metric None Relay output RS-485 serial interface (galvanically isolated) LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logging module*) None Relay output 3rd Analog output Choose also analog output signal for Ch3 Data logging module*) Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) Conduit fitting for wire conduit (NPT1/2") Connector (M12, 8 pin) and plug with 5m cable Connector (M12, 8 pin) and plug (screw terminal) Wall Mounting Wall mounting plate (for adapting to HMP228) Pipe / pole installation Pipe / pole installation with rain shield DIN-rail installation Special sensor for fluids Stainless steel grid Stainless steel grid (for applications with linear flow > 1 m/s) None None English None Service cable for PC MI70LINK software for Windows® + service cable for PC Service cable for PC, USB MI70LINK software for Windows® + USB service cable for PC ISO9001 compliant calibration (factory calibration) None *) Choose data logging module only once (option 11 or 12) 11 A B C D E F G H J K L M N P X (Relay-1) (AOUT-1) (214728SP) (214780SP) (212142) (212416) (214829) (215108) (215109) (215094) T output is desired 0 1 2 4 5 6 (19446ZZ) (215005) (219685) (219916) 13 Additional feature Additional feature 2 $180 $160 $350 15 A B C D Interface cable connection $60 $60 16 0 1 2 3 4 $90 $100 $110 $90 D E A B $40 $60 $90 $90 A 1 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Example of order code with typical settings: MMT330 2 B 0 E 1 0 1 P C A L 2 0 0 A 0 2 D A B A A Transmitter housing installation 17 18 Sensor Sensor protection 19 Probe installation accessories 20 A B C D E $320 $80 $200 $210 $60 21 22 23 User's guide PC Accessories Calibration ----- None (-40...+140°F) -40...+60°C (-40...+176°F) -40...+80°C (-40...+248°F) -40...+120°C (-40...+356°F) -40...+180°C (-4...+140°F) -20...+60°C (-4...+176°F) -20...+80°C (-4...+248°F) -20...+120°C (-4...+356°F) -20...+180°C (+32...+140°F) 0...+60°C (+32...+ 212°F) 0...+100°C (+32...248°F) 0...+120°C (+32...356°F) 0...+180°C (-76...+140°F) -60...60 °C __________________°C / ___________________ F Metric Non-metric None Relay output RS-485 galvanic isolation LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logging module*) None Relay output 3rd Analog output Choose also analog output signal for Ch3 Data logging module*) Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) Conduit fitting for wire conduit (NPT1/2") Connector (M12, 8 pin) and plug with 5m cable Connector (M12, 8 pin) and plug (screw terminal) Wall Mounting Wall mounting plate (for adapting to HMP228) Pipe / pole installation Pipe / pole installation with rain shield DIN-rail installation Special sensor for fluids Stainless steel grid Stainless steel grid (for applications with linear flow > 1 m/s) None Swagelok connector NPT 1/2" Swagelok connector ISO 3/8" None English None Service cable for PC MI70LINK software for Windows + service cable for PC Service cable for PC, USB MI70LINK software for Windows® + USB service cable for PC ISO9001 compliant calibration (factory calibration) None *) Choose data logging module only once (option 11 or 12) A B C D E F G H J K L M N P X 1 2 (Relay-1) (RS485-1) (Relay-1) (AOUT-1) (214728SP) (214780SP) (212142) (212416) (214829) (215108) (215109) (215094) 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 A B C D $60 $60 0 1 2 3 4 $90 $100 $110 $90 2 (HM47453SP) (220752) (SWG12NPT12) (SWG12ISO38) (M210566EN) (19446ZZ) (215005) (219685) (219916) D E A K L A B A B C D E $40 $60 $90 $90 A 1 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 194 SPECIAL Output units 14 0 1 3 6 A (M210566EN) 12 $180 $160 $260 $320 $350 2 (HM47453SP) (220752) Analog output range for temperature NOTE: - Choose option A, if no 1 2 (Relay-1) (RS485-1) $160 $370 Channel 1 Channel 2 Channel 3, choose A, if not needed Channel 1 Channel 2 Channel 3, choose A, if not needed 11 PRICE $1,810 1 Shaded sections indicate typical selections. Example of order code with typical settings: MMT330 7 S 0 E 1 0 1 P C A L 2 0 0 A 0 2 D K B A A 1 195 MMT338 Moisture and Temperature Transmitter for Oil MM70 Hand-Held Moisture Meter for Oil For pressurized pipelines 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 MMT330 8 0 8 V W X 1 2 3 0 E 0 1 (HMT300PWS) (DcDc-1) (Power-1) (Power-1 and 215991) Not IP65 Vaisala HUMICAP® Humidity and Temperature Transmitter Transmitter type MMT338 Probe cable length 2 m cable (6.6 ft) for standard probe 5 m cable (16.4 ft) for standard probe 10 m cable (32.8 ft) for standard probe 2 m cable (6.6 ft) for long probe 5 m cable (16.4 ft) for long probe 10 m cable (32.8 ft) for long probe ----None Measurement parameters aw+T Display No display Graphic LCD with backlight Power supply 10...35 VDC 24 VAC Galvanic isolation for outputs 10...35 VDC 24 VAC Universal AC -power (100....240 VAC) Universal AC -power (100....240 VAC) + US -power cord External US AC-adapter (for LAN/WLAN interface in USA and Canada) Analog output 4... 20 mA 0... 20 mA 0... 1 V 0... 5 V 0... 10 V Analog output No 3rd analog output parameter and scaling T (range: see below) for Ch1&Ch2(&Ch3) aw (0...1) (0...1) SPECIAL Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) Define scale for Ch1:_____________ Ch2:____________ Optional Ch3:______________ 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2 A 1 PRICE $2,180 $160 $370 $120 $260 $460 $320 0 1 2 3 9 $80 $200 $210 $60 1 2 3 4 5 Analog output range for temperature NOTE: - Choose option A, if no T output is desired 12 SPECIAL Output units 13 Additional feature 14 Additional feature 2 15 Interface cable connection 16 Transmitter housing installation 17 18 Sensor Sensor protection 19 Probe installation accessories 20 User's guide 21 22 23 PC Accessories Calibration ----- None (-40...+140°F) -40...+60°C (-40...+176°F) -40...+80°C -40...+120°C (-40...+248°F) (-40...+356°F) -40...+180°C (-4...+140°F) -20...+60°C (-4...+176°F) -20...+80°C (-4...+248°F) -20...+120°C (-4...+356°F) -20...+180°C (+32...+140°F) 0...+60°C (+32...+ 212°F) 0...+100°C (+32...248°F) 0...+120°C (+32...356°F) 0...+180°C (-76...+140°F) -60...60 °C __________________°C / ___________________ F Metric Non-metric None Relay output RS-485 galvanic isolation LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logging module*) None Relay output 3rd Analog output Choose also analog output signal for Ch3 Data logging module*) Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) Conduit fitting for wire conduit (NPT1/2") Connector (M12, 8 pin) and plug with 5m cable Connector (M12, 8 pin) and plug (screw terminal) Wall Mounting Wall mounting plate (for adapting to HMP228) Pipe / pole installation Pipe / pole installation with rain shield DIN-rail installation Special sensor for fluids Stainless steel grid Stainless steel grid (for applications with linear flow > 1 m/s) Ball valve set Pressure fitting NPT1/2 Pressure fitting ISO 1/2 None English None Service cable for PC MI70LINK software for Windows + service cable for PC Service cable for PC, USB MI70LINK software for Windows® + USB service cable for PC ISO9001 compliant calibration (factory calibration) None *) Choose data logging module only once (option 11 or 12) 12 13 14 (214728SP) (214780SP) (212142) (212416) (214829) (215108) (215109) (215094) 6 7 A 8 9 10 11 12 13 14 0 PRICE $840 $840 $780 $2,080 0 1 2 3 5 $60 $35 $95 $90 A 0 1 2 $80 $30 A 0 1 2 3 $60 $60 $60 A B $60 0 1 $200 A B 0 TOTAL QTY TOTAL VALUE * select item A, if only probe is ordered ** check the availability and special delivery time from your local Vaisala representative. Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Example of order code with typical settings: MM70 D 1 2 (Relay-1) (AOUT-1) 7 8 11 A B C D E F G H J K L M N P X (Relay-1) (RS485-1) 2 3 4 5 6 9 10 A C C C P P P X X X Channel 1 Channel 2 Channel 3, choose A, if not needed 11 1 1 2 3 4 5 MM70 1 A 1 A Vaisala HUMICAP® Hand-held Moisture Meter for Oil no indicator * A Indicator type B rechargeable with Euro AC-adapter (MI70USADAPTER+26755) D rechargeable with US AC-adapter (18950) (4 pieces) K alkaline batteries only Reserved for future use 1 Probe type MMP78 A Sensor Special sensor for fluids (HUMICAP180L2) 1 Filter Stainless steel filter (HM47453SP) A Indicator accessories no indicator accessories (MI70LINK) MI70LINK (software with RS 232 cable) (27168ZZ) Analog output-signal cable MI70LINK and analog output-signal cable (MI70LINK + 27168ZZ) MI70LINK software with USB cable (219687) Calibration at room temperature Installation accessories no accessories (DRW212076 + BALLVALVE-1) Ball valve set (incl. fitting body + blanking plug) Connecting adapter to NPT ½" (210662) Measured variables aw+T Connection cable no connection cable Connection cable to HMP228 (27159ZZ) to a transmitter (DRW216050) Connection cable to MMT318 (211339) Connectioin cable to MMT300 Series Probe cable length 1.9 meter 1.9 meter + extension cable 10m (213107) Carrying case no carrying case (211402) Aluminum carrying case for indicator and 2 probes Manual language No manual English Reserved for future use Accessories and Spare Parts: 0 1 2 4 5 6 $180 $160 $260 $320 $350 0 1 3 6 $180 $160 $350 A B C D 1 A Description: Manual press tool Plastic wrench Calibration adapter for HMK15 Protecting cap MM78 Cable extension 10m Ball valve assembly Battery NiMH 4.8 for the MI70 MI70 US Adapter 1 A 5 A 0 A 0 Order Code: HM36854SP DRW216040SP 211302 DRW215988SP 213107SP BALLVALVE-1 26755 MI70USADAPTER A 1 B 0 PRICE $30 $30 $30 $30 $60 $80 $30 $60 $60 $60 0 1 2 3 4 $90 $100 $110 $90 2 (HM47453SP) (220752) (DRW212076 + BALLVALVE-1) (NPTFITBODASAP) (DRW212076) (M210566EN) (19446ZZ) (215005) (219685) (219916) D E M N V $80 A B A B C D E $40 $60 $90 $90 A 1 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings: MMT330 8 V 0 E 1 0 1 P C A L 2 0 0 A 0 2 D N B A A 196 1 197 Vaisala CARBOCAP® Carbon Dioxide Probe GMP343 GMT221 and GMT222 CO2 Transmitters 3 4 5 6 7 8 GMP343 A B 9 10 11 PRICE 0 $2,800 $3,090 1 2 3 4 5 6 2 A B C 1 2 3 N A B C $40 $50 $60 0 1 2 $860 $60 N A B C $120 $80 $200 0 1 4 5 6 7 8 $80 N A $40 9 0 A B TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 10 2 3 4 5 6 0 7 8 9 10 11 12 0 PRICE $840 H J K L M B C D E F G 0 N A B $10 $50 0 1 $70 A B $120 0 N (25665GMSP) A (210848GMSP) C $80 $100 1 X Example: custom setpoint for relay 1 1000 ppm CO2 -> Relay will be activated above 1000 ppm CO2 Alarm relay 2 A X setpoint not activated custom setpoint for relay 2______ ppm / % CO2 Example: custom setpoint for relay 2 4% CO2 -> Relay will be activated above 4% CO2 Notes: * The range 0...5000 ppm CO2 and 0…2 % CO2 have reduced accuracy specifications above 4000 ppm CO2. 11 ** The analog output type may be selected and re-scaled using PC connection cable. *** If the selection is RS-485, the device may be powered up in the RS-232 service mode for user settings. See user manual for details. ****This selection includes: MI70 indicator with a rechargeable battery AC adapter with AUS, EUR, UK and US plugs MI70Link software with RS232 cable (PC<->MI70) 2 m interface cable (GMP343 <-> MI70) ***** PC connecton kit includes PC connection cable (213379) and USB adapter (USB-D9 Serial connection Cable, 219686) GMP343 A 1 A 1 12 Accessories Manual no accessories Serial COM adapter no manual English (19040GM) O A O N 0 B Order Code GMP343BRACKET GMP343FLANGE GMP343FILTER 215521 GMP343ADAPTER JUNCTIONBOX-8 GMP343Z200SP GMP343Z600SP GMP343Z1000SP 213379 DRW216050SP 219686 215519 215520 PRICE $60 $110 $80 $120 $120 $50 $50 $70 $80 $80 $60 $90 $150 $150 $100 TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. A 0 1 A B (* special accuracy specification Accessories and Spare Parts: Description Included in the default configuration ----------------------- Wall mount bracket Mounting flange Included in the default configuration ----------------------- Standard diffusion filter (IP65) + filter cover of the diffusion model Diffusion filter (sintered filter, IP66) + filter cover Calibration adapter Junction box Probe cable (with M12 type female conn.), 2 meter Probe cable (with M12 type female conn.), 6 meter Probe cable (with M12 type female conn.), 10 meter PC connection cable Interface cable for MI70, 2 meter USB adapter (USV-D9 Serial connection cable) Soil adapter kit for horizontal positioning (includes PTFE filter) Soil adapter kit for vertical positioning (includes PTFE filter) 198 1 1 Vaisala CARBOCAP® CO2 Transmitter GM T 22 Vaisala CARBOCAP® CO2 Transmitter Measurement range 0…2 %CO2 1 (GMT221) 0...3 %CO2 1 0...5 %CO2 1 0...10 %CO2 1 0...20 %CO2 1 (GMT222) 0…2000 ppmCO2 adjusted at 1000 ppm (* 2 0…2000 ppmCO2 2 0...3000 ppmCO2 2 0...5000 ppmCO2 2 0…7000 ppmCO2 2 0…10000 ppmCO2 2 Place holder for future option, not available at this time Probe installation none accessories mounting clips, 2 pcs (25245GMSP) mounting flange (GM45156SP) Field check none adapter (26150GM) adapter LED lights only Display on cover LED lights + backlit digital LCD display Place holder for future option, not available at this time probe in transmitter (wall model) Wall/remote use probe with 2 m cable (remote installation of probe) probe with 10 m cable (remote installation of probe) Alarm relay 1 setpoint not activated custom setpoint for relay 1______ ppm / % CO2 PROBE Vaisala CARBOCAP Carbon Dioxide Probe 1 Sampling method diffusion flow through 2 Measurement range of 0…1000 ppm CO2 the probe: 0…2000 ppm CO2 0...3000 ppm CO2 0...4000 ppm CO2 0...5000 ppm CO2 * 0…2 % CO2 * 3 Analog output 0...5V selection ** 0...2.5 V 4...20 mA 4 Digital output RS-232 selection RS-485 *** 5 Probe cable none probe cable (with M12 type female connector), 2 m probe cable (with M12 type female connector), 6 m probe cable (with M12 type female connector), 10 m 6 Measurement indicator none MI70 and accessories MI70 indicator and interface cable, 2 m**** MI70 interface cable, 2 m 7 Calibration accessories none calibration adapter for diffusion model. PC connection kit***** calibration adapter for diffusion model and PC connection kit***** 8 Mounting accessories none mounting flange 9 Wiring accessories none junction box 10 Reserved for future use 11 Manual no manual English 2 TRANSMITTER UNIT 1 ® Examples of order codes with typical settings: Transmitter with probe GM T 22 1 L 0 N 0 B 0 N 1 A 0 B Accessories and Spare Parts: Description: In-soil adapter kit Goretex membrane spare filter plus cap for GMP221 Goretex membrane spare filter plus cap for GMP222 Calibration Kit for interchangeable probes Order Code: 211921GM PRICE $60 25378GMSP $50 25879GMSP GMK220 $50 $1,600 199 OMT355 Oxygen Transmitter GM70 Hand-held Carbon Dioxide Meter 1 1 2 3 4 5 6 7 8 9 GM70 Vaisala CARBOCAP® Hand-held CO2 Meter Indicator type no indicator * A rechargeable with Euro AC-adapter B rechargeable with US AC-adapter D Indicator accessories no indicator accessories MI70LINK (software with RS232 cable) analog output signal cable (27168ZZ) MI70LINK and analog output-signal cable (MI70LINK+ 27168ZZ) MI70LINK software with USB cable (219687) Accessories for no indicator cables adapter cable for transmitters) transmitter checking (GMA70) diffusion (handle GMH70) Sampling method pump (GM70PUMP) + Nafion® membrane tubing (212807GM) 2 3 4 5 7 A 8 9 1 PRICE $840 $840 0 1 2 3 4 $60 $35 $95 $90 with a flange adapter for in-line mounting Ambient environment (range 2...25 %O2) with a wall mounting bracket 0…2000 ppm CO2 C 0…3000 ppm CO2 D 0...5000 ppm CO2 E 0…7000 ppm CO2 F 0…10000 ppm CO2 G 0…2 % CO2 H 0...3 % CO2 J 0...5 % CO2 0...10 % CO2 0...20 % CO2 no accessories field check adapter K 3 Analog output range for oxygen Define O2 special range from 8 Cable bushings $70 9 In-line calibration option QTY $5,690 1 (216615) PTFE filter with stainless steel net 2 $160 3 $290 O2 (0...5%) A O2 (0...10%) B O2 (0...15%) C O2 (0...20%) D O2 (0...25%) E O2 (0...100%) K __________%O 2 __________%O 2 to X 4...20 mA 1 0...20 mA 2 3 mA or below A 21 mA or higher B Fault state 3 mA can be chosen only if signal output is 4...20 mA (can be reconfigured in the field)** * select item A, only if the handle or pump with probe is ordered $4,850 $5,200 7 Material of sample wetted O-rings TOTAL $4,850 (216653) B $6,060 Setpoint: _____________ %O 2 (hysteresis 1%O2) A B PRICE E PTFE filter non-compatible for 100% O2 NOTE: $140 1 A A with a sample cell and a wall mounting bracket No filter (sample cell installation) 6 Relay settings (MI70CASE) 9 10 11 12 13 Sample cell (range 0... 100 %O2)* (can be reconfigured in the field)** 0 1 8 C 5 Fault state current for analog output A 7 D (can be reconfigured in the field)** 0 1 (26150GM) 6 with a flange adapter for in-line mounting 4 Signal output L M 5 with a sample cell and a wall mounting bracket Stainless steel net SPECIAL: 4 Sample cell (range 0... 25 %O2) $160 $900 $1,580 1 2 3 In-line (range 0... 100 %O2)* 2 Filter type NOTE: 2 OMT355 In-line (range 0... 25 %O2) (can be reconfigured in the field) A B interchangeable probe: Space holder for future option Carrying case no carrying case carrying case Manual no manual English manual Vaisala SPECTRACAP® Oxygen Transmitter OMT355 1 Installation type Measurement range of Probe accessories 6 Relay opens ONLY when fault state occurs 1 Relay opens when O2 value decreases below setpoint X Relay opens when O2 value increases above setpoint Y EPDM A Kalrez Cable gland M20x1.5 (cable diameter 8... 11 mm) Conduit fitting NPT1/2 (inner threads) Connector (8 pin M12 male) with 2m cable Connector (8 pin M12 male) with 6m cable Connector (8 pin M12 male) with 10m cable no Calibration gas inlet with check valve B (214728SP) (217197) (GMP343Z200SP) (GMP343Z600SP) (GMP343Z1000SP) $980 1 2 3 4 5 $40 $50 $60 A B $640 1 10 Accessories None 11 User's guide language Serial interface cable for PC no user's guide 12 Calibration 13 Maintenance and repair English ISO 9001 compliant factory calibration Standard maintenance and repair 2 (19446ZZ) $40 A B 1 A QTY TOTAL VALUE *Oxygen compatibility certification delivered with the 0…100%O2 range Selections in bold are included in the purchase price. TOTAL VALUE **Requires a Serial Interface Cable and Terminal programme on PC Items in italics are available at an additional cost. Shaded options indicate most typical selections. Example of an order code with typical settings: GM70 D 4 A 1 M 1 A Accessories and Spare Parts: Description: US Adapter Battery NiMH 4.8 battery for MI70 Pump for GM70 Hand-held CO2 meter Handle for GM70 Nafion® membrane tubing 200 Order Code: MI70USADAPTER 26755 GM70PUMP GMH70 212807GM Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 1 Example of order code with typical settings: OMT355 A 2 B 1 A 1 A 1 A 1 B 1 A B PRICE $60 $30 $1,050 $440 $200 Spare parts & accessories Item Stainless steel net PTFE filter with EPDM O-ring PTFE filter with Kalrez O-ring Flange adapter with EPDM O-ring Flange adapter with Kalrez O-ring Wall mounting bracket Sample/calibration cell with EPDM Sample/calibration cell with Kalrez Cable gland Order code 216615 217055 217056 217053 217054 216653 217052 216619 214728SP PRICE $170 $125 $215 $165 $385 $120 $915 $1,220 $15 Item Conduit fitting NPT1/2 (inner threads) Connector for transmitter body EPDM O-rings for sample cell Kalrez O-rings for sample cell Connection cable, 2 m Connection cable, 6 m Connection cable, 10 m Junction box for 8-pole cable Serial interface cable for PC EPDM flange adapter gasket Kalrez flange adapter gasket Order code 217197 214806SP 217198 217199 GMP343Z200SP GMP343Z600SP GMP343Z1000SP junctionbox-8 19446ZZ 216347 216833 PRICE $35 $25 $60 $315 $40 $50 $60 $50 $40 $25 $40 201 OMT364 Nonincendive Oxygen Transmitter Vaisala Pressure, Humidity and Temperature Transmitter PTU301 - Wall Mount Vaisala SPECTRACAP® Oxygen Transmitter OMT364 1 Transmitter type 2 Installation type OMT 360 OMT364 In-line (range 0... 25 %O2) with a flange adapter for in-line mounting Ambient environment (range 2...25 %O2) with a wall mounting bracket Sample cell (range 0... 25 %O2) with a sample cell and a wall mounting bracket No filter (sample cell installation) 3 Filter type 4 4 (216653) Stainless steel net 1 A 1 A PRICE A $7,400 B $7,400 C (216615) PTFE filter with stainless steel net 4 Analog output range for oxygen (can be reconfigured in the field) $8,240 1 2 $160 3 $290 O2 (0...5%) A O2 (0...10%) B O2 (0...15%) C O2 (0...20%) D O2 (0...25%) SPECIAL: Define O2 special range from __________%O2 E to __________%O2 X Specifications are valid only for measurement range 0...25%O2 NOTE: 4...20 mA 5 Signal output (can be reconfigured in the field)* 0...20 mA 6 Fault state current for analog output (can be reconfigured in the field)* 1 2 3 mA or below A 21 mA or higher B Fault state 3 mA can be chosen only if signal output is 4...20 mA NOTE: Relay opens ONLY when fault state occurs 7 Relay settings Relay opens when O 2 value decreases below setpoint Setpoint: _____________ %O2 Relay opens when O 2 value increases above setpoint Setpoint: _____________ %O2 Define selected custom setpoint when required. Factory setpoint is 10%O2, hysteresis is 1%O2 8 Cable bushings Cable gland M20x1.5** (cable diameter 8... 11 mm) Conduit fitting NPT1/2 (inner threads) 9 In-line calibration option no Calibration gas inlet with check valve no user's guide 10 User's guide language English 11 Approval 1 2 3 (214728SP) (217197) A B Special 1 2 $640 A B 1 FM (USA, Canada) A 12 1 13 14 A QTY *Requires a Serial Interface Cable and Terminal programme on PC. Reconfiguration should be done only in a safe area Item 1 1 Vaisala Pressure, Humidity and Temperature Transmitter PTU300 1 Transmitter type PTU301 for wall mounting 1 2 Pressure range 500...1100 hPa Class A / one sensor 500...1100 hPa Class B / one sensor 500...1100 hPa Class A / two sensors 500...1100 hPa Class B / two sensors 50...1100 hPa One sensor, class B only 50...1100 hPa Two sensors, class B only 3 Wall mount probe fixed with short cable Probe holder plate recommended in selection 17 4 Additional temperature probe No probe 5 Display No display Graphic LCD with backlight (HMT300PWS) 6 Power supply 10...35 VDC, 24 VAC Galvanic isolation for outputs 10...35 VDC 24 VAC (DCDC-1) Universal AC power (100....240 VAC) (POWER-1) Universal AC power (100....240 VAC) + US power cord (POWER-1 AND 215991) External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 Mandatory with two pressure sensors 7 Output signal RS232C only, No Analog output RS232C + Optional Analog output (Ch1, Ch2, Ch3) 4... 20 mA RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 20 mA RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 1 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 5 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 10 V Parameter and scaling for No Analog output analog output (Ch1, Ch2, Ch3) RH (0...100 %RH) T (range: see below) Td (-20...100 °C) (-4...+212 °F) Tdf (-20...100 °C) (-4...+212 °F) a (0...600 g/m3) (0...262 gr/ft3) Tw (0...100 °C) (+32...+212 °F) x (0...500 g/kg d.a) (0...3500 gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) pw (0…1000 hPa) (0…14.5 psi) pws (0…1000 hPa) (0…14.5 psi) dT (-10...+50 °C) (14...+122 °F) P (pressure range: selection in item 2) 8 9 10 11 Analog output range for temperature Note: Select option A, if T output is not required 14 TOTAL VALUE Example of order code with typical settings: OMT360 4 A 2 B 1 15 A 1 A 1 B 1 A 1 A 16 Spare parts & accessories Item Stainless steel net PTFE filter with Kalrez O-ring Flange adapter with Kalrez O-ring Wall mounting bracket Sample/calibration cell with Kalrez Conduit fitting Kalrez O-rings for sample cell/flange adaptor Serial interface cable for PC USB-RJ45 Serial Interface Cable Cable gland Kalrez Flange adaptor gasket 17 Order code 216615 217056 217054 216653 216619 217197 217199 19446ZZ 219685 214728SP 216833 PRICE $170 $215 $385 $120 $1,220 $35 $315 $40 ……………….. $90 ……………….. $15 $40 3 A 4 0 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 0 A 1 2 3 4 5 6 18 19 Note! For safe area use only. Note! For safe area use only. 20 21 22 23 $420 A 8 0 0 1 $320 A B C D K $80 $200 $210 $60 0 1 2 3 4 5 $190 $190 $190 $190 $190 A A B B C C D D E E F F G G H H J J K K L L M M A X X P X (-40...+140 °F) (-4...+140 °F) (+32...+140 °F) special range :_______________________________ Standard Metric Non-metric Mandatory with two pressure sensors or analog output Optional module No module Relay output (RELAY-1) -Not possible with power supply module RS485 serial interface (galvanically isolated) (RS485-1) LAN (Ethernet) interface + 2 m cable (RJ45) Not possible with Universal AC power WLAN (Wireless Ethernet) interface + antenna With short cable probe only Data logger module (214728SP) Cable bushings Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable) Note: The universal AC power (214780SP) Conduit fitting NPT1/2" must not be connected 8-pole connector with 5m cable (212142) through the 8-pole connector 8-pole counter connector with screw terminals (212416) or D9 adapter D9-adapter Only for RS232C, RS485 and DC supply (19498) Pressure fitting Barbed fitting for 1/8" hose Quick connector with shutoff valve for 1/8" hose (19886, 25328 + 25329) Transmitter installation Normal mounting Wall mounting plate (214829) Pole installation kit (215108) Pole installation kit with Rain Shield (215109) DIN rail kit (215094) Probe holder plate Recommended with short cable probe (226252) General purpose HUMICAP180 Humidity sensor Chemical purge HUMICAP180C General purpose and high chemical concentrations HUMICAP180R Chemical purge HUMICAP180RC (DRW010281SP) Sensor protection PPS plastic grid & stainless steel netting (DRW010276SP) PPS plastic grid (HM47280SP) Sintered stainless steel filter HM47453SP Stainless steel grid Probe installation accessories No probe installation accessories User's Guide language No manual English No PC Accessories Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB software driver MI70LINK software for Windows® with USB service cable (219916) Calibration Certificate ISO9001 compliant factory calibration / No Calibration Contract Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings: PTU300 1 1 A 0 0 A 1 B C P 202 PRICE $2,070 $200 $620 $420 Define quantity for Ch1:_______________ Ch2:______________ Define scale for Ch1:_______________ Ch2:______________ Ch3:______________ Channel 1 Channel 2 Channel 3 only for pressure No analog output -40...+60 °C -20...+60 °C 0...+60 °C 5 A B F K X 12 Output format 13 Output units **Cable gland usable only in the USA according to FM approval Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. 2 1 A B 0 1 2 4 5 6 $180 $160 $260 $320 $350 A B C D E $60 $60 $70 1 2 $40 A B C D E F $90 $100 $110 $90 $90 1 4 A C $60 $60 B C D E 0 A B 0 1 2 3 4 $40 $60 $90 $90 A TOTAL QTY TOTAL VALUE B 1 B 0 A 1 A A B 0 B 0 A 203 Vaisala Pressure, Humidity and Temperature Transmitter PTU303 - Outdoor Use Item 1 Vaisala Pressure, Humidity and Temperature Transmitter PTU300 for general use Transmitter type PTU303 2 Pressure range 500...1100 hPa Class A / one sensor 500...1100 hPa Class B / one sensor 500...1100 hPa Class A / two sensors 500...1100 hPa Class B / two sensors 50...1100 hPa One sensor, class B only 50...1100 hPa Two sensors, class B only 3 Probe cable length 2 m cable 5 m cable 10 m cable 4 Additional temperature probe No probe 5 Display No display Graphic LCD with backlight 6 Power supply 10...35 VDC, 24 VAC (HMT300PWS) Galvanic isolation for outputs 10...35 VDC 24 VAC (DCDC-1) Universal AC power (100....240 VAC) (POWER-1) Universal AC power (100....240 VAC) + US power cord (POWER-1 AND 215991) Not IP65 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Mandatory with two pressure sensors 7 Output signal RS232C only, No Analog output 4... 20 mA RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 20 mA RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 1 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 5 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 10 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) Parameter and scaling for No Analog output analog output (Ch1, Ch2, Ch3) RH (0...100 %RH) T (range: see below) Td (-20...100 °C) (-4...+212 °F) Tdf (-20...100 °C) (-4...+212 °F) a (0...600 g/m3) (0...262 gr/ft3) Tw (0...100 °C) (+32...+212 °F) x (0...500 g/kg d.a) (0...3500 gr/lb) (-9.5...+652.6 Btu/lb) h (-40...1500 kJ/kg) pw (0…1000 hPa) (0…14.5 psi) pws (0…1000 hPa) (0…14.5 psi) dT (-10...+50 °C) (14...+122 °F) P (pressure range: selection in item 2) Vaisala Pressure, Humidity and Temperature Transmitter PTU307 - Warmed Probe 1 3 3 2 3 4 0 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 A 1 2 3 4 5 6 PRICE $2,110 $200 $620 $420 $420 B C D $150 $300 0 0 1 $320 A B C D K $80 $200 $210 $60 0 1 2 3 4 5 $190 $190 $190 $190 $190 A A B B C C D D E E F F G G H H J J K K L L M M A Item 1 Vaisala Pressure, Humidity and Temperature Transmitter PTU300 Transmitter type PTU307 for high humidity 500...1100 hPa Class A / one sensor 2 Pressure range 500...1100 hPa Class B / one sensor 500...1100 hPa Class A / two sensors 500...1100 hPa Class B / two sensors 50...1100 hPa One sensor, class B only 50...1100 hPa Two sensors, class B only 3 Probe cable length 2m cable 5 m cable 10 m cable No probe 4 Additional temperature probe 2 m cable 5 m cable 10 m cable No display 5 Display Graphic LCD with backlight 10...35 VDC, 24 VAC (HMT300PWS) 6 Power supply Galvanic isolation for outputs 10...35 VDC 24 VAC (DCDC-1) Universal AC power (100....240 VAC) (POWER-1) Universal AC power (100....240 VAC) + US power cord (POWER-1 AND 215991) External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 Mandatory with two pressure sensors RS232C only, No Analog output 7 Output signal RS232C + Optional Analog output (Ch1, Ch2, Ch3) 4... 20 mA 0... 20 mA RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 1 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 5 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 10 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) Parameter and scaling for No Analog output analog output (Ch1, Ch2, Ch3) RH (0...100 %RH) T (range: see below) Td (-20...100 °C) (-4...+212 °F) Tdf (-20...100 °C) (-4...+212 °F) a (0...600 g/m3) (0...262 gr/ft3) Tw (0...100 °C) (+32...+212 °F) x (0...500 g/kg d.a) (0...3500 gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) pw (0…1000 hPa) (0…14.5 psi) pws (0…1000 hPa) (0…14.5 psi) dT (-10...+50 °C) (14...+122 °F) P (pressure range: selection in item 2) Define quantity for Ch1:_______________ Ch2:______________ Define scale for Ch1:_______________ Ch2:______________ Ch3:______________ Channel 1 Channel 2 Channel 3 only for pressure No analog output (-40...+140 °F) -40...+60 °C (-4...+140 °F) -20...+60 °C (+32...+140 °F) 0...+60 °C special range :_______________________________ Output format Standard Output units Metric Non-metric Optional module No module Mandatory with two pressure sensors or analog output (RELAY-1) -Not possible with power supply module Relay output (RS485-1) RS485 serial interface (galvanically isolated) LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logger module Cable bushings Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable) (214728SP) Note: The universal AC power Conduit fitting NPT1/2" (214780SP) 8-pole connector with 5m cable (212142) must not be connected through the 8-pole connector 8-pole counter connector with screw terminals (212416) Only for RS232C, RS485 and DC supply or D9 adapter D9-adapter (19498) Pressure fitting Barbed fitting for 1/8" hose (19886, 25328 + 25329) Quick connector with shutoff valve for 1/8" hose Transmitter installation Normal mounting (214829) Wall mounting plate (215108) Pole installation kit (215109) Pole installation kit with Rain Shield DIN rail kit (215094) Humidity sensor General purpose HUMICAP180 Chemical purge HUMICAP180C General purpose and high chemical concentrations HUMICAP180R Chemical purge HUMICAP180RC Sensor protection PPS plastic grid & stainless steel netting (DRW010281SP) PPS plastic grid (DRW010276SP) Sintered stainless steel filter (HM47280SP) Stainless steel grid (HM47453SP) Probe installation No kit accessories Duct Installation kit (210697) Cable Gland AGRO (HMP247CG) User's Guide language No manual English No PC Accessories Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB software driver MI70LINK software for Windows® with USB service cable (219916) Calibration Certificate ISO9001 compliant factory calibration / No Calibration Contract Selections in bold are included in the prices of the basic versions Selections in italic are available at an extra price. Shaded sections indicate typical selections. X X 14 15 16 17 18 19 20 21 22 23 8 9 10 11 Analog output range for temperature Note: Select option A, if T output is not required A B F K X No analog output -40...+60 °C -20...+60 °C 0...+60 °C 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 A 1 2 3 4 5 6 PRICE $3,100 $200 $620 $420 $420 E F G $160 $370 0 1 2 3 $160 $180 $220 0 1 $320 A B C D K $80 $200 $210 $60 0 1 2 3 4 5 $190 $190 $190 $190 $190 A A B B C C D D E E F F G G H H J J K K L L M M A X X P (-4...+140 °F) (+32...+140 °F) special range :_______________________________ Standard Metric Non-metric Optional module No module Mandatory with two pressure sensors or analog output Relay output (RELAY-1) -Not possible with power supply module RS485 serial interface (galvanically isolated) (RS485-1) LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logger module Cable bushings Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable) (214728SP) Note: The universal AC power Conduit fitting NPT1/2" (214780SP) 8-pole connector with 5m cable must not be connected (212142) 8-pole counter connector with screw terminals through the 8-pole connector (212416) D9-adapter Only for RS232C, RS485 and DC supply or D9 adapter (19498) Pressure fitting Barbed fitting for 1/8" hose Quick connector with shutoff valve for 1/8" hose (19886, 25328 + 25329) Transmitter installation Normal mounting Wall mounting plate (214829) Pole installation kit (215108) Pole installation kit with Rain Shield (215109) DIN rail kit (215094) Composite sensor Humidity sensor HUMICAP180C Chemical purge HUMICAP180C General purpose and high chemical concentrations HUMICAP180RC Chemical purge HUMICAP180RC Sensor protection PPS plastic grid & stainless steel netting (DRW010281SP) PPS plastic grid (DRW010276SP) Sintered stainless steel filter (HM47280SP) Stainless steel grid (HM47453SP) Probe installation No kit Duct Installation kit accessories (210697) Cable Gland AGRO (HMP247CG) 2 x Duct installation kits (RH+T probes) (210697 + 215003) User's Guide language No manual English No PC Accessories Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB software driver MI70LINK software for Windows® with USB service cable (219916) Calibration Certificate ISO9001 compliant factory calibration / No Calibration Contract Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Shaded sections indicate typical selections. A B F K X 12 Output format for serial interface 13 Output units 1 14 A B 0 1 2 4 5 6 $180 $160 $260 $320 $350 A B C D E $60 $60 $70 1 2 15 16 17 $40 A B C D E $90 $100 $110 $90 18 19 1 4 A C $60 $60 B C D E 20 21 0 1 2 $80 $60 22 A B 0 1 2 3 4 $40 $60 $90 $90 A TOTAL QTY TOTAL VALUE 23 Example of order code with typical settings: PTU300 7 1 E 1 0 A 1 B C P Vaisala Meteorological Installation Kit for PTU300 Transmitters 1 Support bar & shield for warmed Td probeNo support bar & shield for warmed Td probe B X (-40...+140 °F) Vaisala Meteorological Installation Kit Example of order code with typical settings PTU300 3 1 B 0 0 A 1 B C P 1 B 0 A 1 A A B 0 B 0 A 2 Additional Accessories: Description Outdoor Solar Radiation Shield 3 Define quantity for Ch1:_______________ Ch2:______________ Define scale for Ch1:_______________ Ch2:______________ Ch3:______________ Channel 1 Channel 2 Channel 3 only for pressure X 8 9 10 11 Analog output range for temperature Note: Select option A, if T output is not required 12 13 2 P Special Special 1 7 7 Order Code DTR502B PRICE $310 3 4 5 Support bar, transmitter mounting plate & shield for warmed Td probe No support bar or radiation shield Support bar and radiation shield for Support bar with DTR502 shield for T probe additional T probe or for Support bar with DTR13 shield for T probe non-warmed RH or Td probe Support bar with DTR502 shield for non-warmed RH or Td probe Support bar with DTR13 shield for non-warmed RH or Td probe No mounting plate Support bar mounting plate Pole mounting plate for support bar/bars Additional transmitter mounting plate No additional transmitter mounting plate Transmitter mounting plate for support bar assembly Transmitter mounting plate for pole assembly Static Pressure Head No Static Pressure Head Static Pressure Head SPH10 Selections in bold are included in the prices of the basic versions Selections in italic have an additional cost Shaded sections indicate typical selections. 1 A B 0 1 2 4 5 6 $180 $160 $260 $320 $350 A B C D E $60 $60 $70 1 2 $40 A B C D E $90 $100 $110 $90 3 4 B C B C D E 0 1 2 6 $80 $60 $160 A B 0 1 2 3 4 $40 $60 $90 $90 A TOTAL QTY TOTAL VALUE B 1 B 0 A 1 B A B 0 B 0 A 1 2 3 4 5 HMT330MIK PRICE 0 1 $580 A B C D E $580 $920 $580 $920 0 1 $120 A B C 0 1 TOTAL QTY TOTAL VALUE $110 $110 $270 Example of order code with typical settings HMT330MIK 1 B 1 A 0 204 205 Vaisala BAROCAP® Digital Barometer PTB330 - One Sensor Vaisala Pressure and Temperature Transmitter PTU30T - Temperature only Item PTU300 1 VAISALA Pressure and Temperature Transmitte Transmitter type PTU30T for pressure and temperature only 500...1100 hPa Class A / one sensor 2 Pressure range 500...1100 hPa Class B / one sensor 500...1100 hPa Class A / two sensors 500...1100 hPa Class B / two sensors 50...1100 hPa One sensor, class B only 50...1100 hPa Two sensors, class B only 2m cable 3 Temperature probe cable length 5 m cable 10 m cable 4 Additional temperature probe No probe No display 5 Display Graphic LCD with backlight 10...35 VDC, 24 VAC (HMT300PWS) 6 Power supply Galvanic isolation for outputs 10...35 VDC 24 VAC (DCDC-1) Universal AC power (100....240 VAC) (POWER-1) Universal AC power (100....240 VAC) + US power cord (POWER-1 AND 215991) Not IP65 External US AC-adapter (for LAN/WLAN interface in USA and Canada) Mandatory with two pressure sensors RS232C only, No Analog output 7 Output signal 4... 20 mA RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 20 mA RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 1 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 5 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) 0... 10 V RS232C + Optional Analog output (Ch1, Ch2, Ch3) Parameter and scaling for No Analog output analog output (Ch1, Ch2, Ch3) T (range: see below) P (pressure range: selection in item 2) Special 8 9 10 11 Analog output range for temperature Note: Select option A, if T output is not required Define scale for No analog output -40...+60 °C -20...+60 °C 0...+60 °C 1 T T 2 3 4 0 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 0 A 0 1 2 3 4 5 6 $620 $420 15 16 17 18 19 20 21 22 23 2 3 $20 $60 0 Ch1:_______________ Ch2:______________ Ch3:______________ Channel 1 Channel 2 Channel 3 only for pressure 4 0 1 $320 A B C D K $80 $200 $210 $60 0 1 2 3 4 5 $190 $190 $190 $190 $190 A C A C A X X X 5 6 7 8 P (-40...+140 °F) (-4...+140 °F) (+32...+140 °F) special range :_______________________________ Standard Metric Non-metric Optional module No module Mandatory with two pressure sensors or analog output (RELAY-1) - Not possible with power supply module Relay output (RS485-1) RS485 serial interface (galvanically isolated) LAN (Ethernet) interface + 2 m cable (RJ45) WLAN (Wireless Ethernet) interface + antenna Data logger module Cable bushings Cable gland (for 8…11 mm cable) (for 0.315…0.433 inch cable) (214728SP) Note: The universal AC power Conduit fitting NPT1/2" (214780SP) 8-pole connector with 5m cable (212142) must not be connected through the 8-pole connector 8-pole counter connector with screw terminals (212416) Only for RS232C, RS485 and DC supply or D9 adapter D9-adapter (19498) Pressure fitting Barbed fitting for 1/8" hose (19886, 25328 + 25329) Quick connector with shutoff valve for 1/8" hose Transmitter installation Normal mounting (214829) Wall mounting plate (215108) Pole installation kit (215109) Pole installation kit with Rain Shield DIN rail kit (215094) Humidity sensor No humidity sensor Sensor protection No sensor protection Probe installation accessories No probe installation accessories User's Guide language No manual English No PC Accessories Service cable for PC (19446ZZ) MI70LINK software for Windows® with RS232 service cable (215005) (219685) Service cable for PC, USB software driver MI70LINK software for Windows® with USB service cable (219916) Calibration Certificate ISO9001 compliant factory calibration / No Calibration Contract Selections in bold are included in the prices of the basic versions Selections in italic are available at an extra price. Shaded sections indicate typical selections. Example of order code with typical settings PTU300 T 1 H 0 0 A 1 A C P 206 1 $420 H J K 9 A B F K X 12 Output format for serial interface 13 Output units 14 PRICE $2,020 $200 10 1 11 A B 0 1 2 4 5 6 $180 $160 $260 $320 $350 A B C D E $60 $60 $70 1 2 12 13 14 1 2 Digital Barometer with One Pressure Sensor PTB330 Accuracy Class Class A A Class B B Display No display 0 Graphical LCD with backlight 1 Power Supply 10...35 VDC 10...35 VDC with external power on/off triggering 10...35 VDC, 24 VAC, galvanical isolation for outputs (DCDC-1) Internal AC-power (110....240 VAC) (POWER-1) Internal AC-power (110....240 VAC) + US power cord (216017) External US AC-adapter (Not IP65) (MI70USADAPTER) Signal Output RS-232 only, no analog output Analog output 4...20 mA 0...20 mA 0...1 V 0...5 V 0...10 V RS-485 (RS485-1) Pressure range 500...1100 hPa 50...1100 hPa Class B only Optional Module (slot 3) No module (RELAY-1) Relay module (Select A with internal AC power) Optional Module (slot 4) No module Customer Connection Cable bushing for 10...14 mm cable Conduit fitting NPT 1/2" 8-pole M12 connector with 5 m cable (212142) 8-pole M12 connector with screw terminals (212416) D9 connector Not IP65 Pressure Fitting Barbed fitting 1/8" Quick connector 1/8" (19886, 25328 + 25329) Optional Connection None Select A only with external AC adapter Plugged Select C or D with internal AC power Cable bushing for 10...14 mm cable Select C or D with internal AC power Conduit fitting NPT 1/2" Installation Normal mounting Adapter plate (for replacing PTB220) (214829) Pole installation kit (215108) Pole installation kit with Rain Shield (215109) DIN rail kit (215094) Calibration ISO 9001 compliant factory calibration / No calibration contract (Separate order form required) ISO/IEC 17025 Accredited calibration Service contract No Service Contract User's Guide language No User's Guide English 3 4 5 6 7 A 8 9 10 11 12 13 14 PRICE $1,790 $1,580 $320 A B C D F K $80 $200 $210 $60 A C D E F G K $160 $160 $160 $160 $160 $160 H J A B $180 A C D E F P $60 $60 $70 E L $40 A B C D 0 1 2 3 4 $90 $100 $110 $90 A B Order Guide 0 A B TOTAL VALUE QTY Items in bold are included in the basic price. $40 A B C D E $90 $100 $110 $90 TOTAL VALUE Selections in italic are available at an additional cost. Shaded sections indicate typical selections. Example of order code with typical settings: PTB330 - One Sensor A 0 A A H A A C E B 0 A 0 B 0 A 0 A B 0 1 2 3 4 $40 $60 $90 $90 Accessories to be ordered separately. Description: Interface cables Serial Interface Cable Software Interface Kit (MI70LINK + serial interface cable) USB-RJ45 Serial Connection Cable MI70LINK software for Windows® + USB-RJ45 Serial Connection Cable Order Code: 19446ZZ 215005 219685 219916 PRICE $40 $60 $90 $90 A TOTAL QTY TOTAL VALUE B 1 B 0 A 1 A 0 A 0 B 0 A 207 Vaisala BAROCAP® Digital Barometer PTB330 - Three sensors Vaisala BAROCAP® Digital Barometer PTB330 - Two Sensors 1 2 3 4 5 6 7 A Digital Barometer with Two Pressure Sensors, Single Redundancy PTB330 Class A A 1 Accuracy Class Class B B No display 0 2 Display Graphical LCD with backlight 1 10...35 VDC 3 Power Supply A 10...35 VDC with external power on/off triggering B 10...35 VDC, 24 VAC, galvanical isolation for outputs C (DCDC-1) External US AC-adapter (Not IP65) K (MI70USADAPTER) A 4 Signal Output RS-232 only, no analog output Analog output 4...20 mA C 0...20 mA D 0...1 V E 0...5 V F 0...10 V G RS-485 K (RS485-1) 500...1100 hPa H H 5-6 Pressure Range (Same range for both sensors) 50...1100 hPa Class B only J J A 7 Optional Module (slot 4) No module 8 Customer Connection Cable bushing for 10...14 mm cable Conduit fitting NPT 1/2" 8-pole M12 connector with 5 m cable (212142) 8-pole M12 connector with screw terminals (212416) D9 connector Not IP65 Barbed fitting 1/8", differential measurement Select E for optional connection (10) 9 Pressure Fitting Barbed fitting 1/8" Quick connector 1/8", differential measurement Select L for optional connection (10) (19886, 25328 + 25329) Quick connector 1/8" (19886, 25328 + 25329) Select A only with external AC adapter None 10 Optional Connection Plugged Cable bushing for 10...14 mm cable Conduit fitting NPT 1/2" Barbed fitting 1/8", for differential measurement Not available with AC-adapter Quick connector 1/8", for differential measurement Not available with AC-adapter (19886, 25328 + 25329) Normal mounting 11 Installation Adapter plate (for replacing PTB220) (214829) Pole installation kit (215108) Pole installation kit with Rain Shield (215109) DIN rail kit (215094) ISO 9001 compliant factory calibration / No calibration contract 12 Calibration ISO/IEC 17025 Accredited calibration (Separate order form required) 13 Service contract No Service Contract No User's Guide 14 User's Guide language English 8 9 10 11 12 13 14 PRICE $2,250 $2,040 $320 $80 $60 $160 $160 $160 $160 $160 $160 C D E F P $60 $60 $70 E F L M $40 $40 A B C D E L $40 0 1 2 3 4 $90 $100 $110 $90 A B A H H A C F B 0 Accessories to be ordered separately Definition: Interface cables Order Code: Serial Interface Cable 19446ZZ 215005 Software Interface Kit (MI70LINK + serial interface cable) 219685 USB-RJ45 Serial Connection Cable 219916 MI70LINK software for Windows® + USB-RJ45 Serial Connection Cable 208 A 4 5 6 7 8 9 10 11 12 13 14 PRICE $2,710 $2,500 $320 A B C K $80 $60 A C D E F G K $160 $160 $160 $160 $160 $160 H J H J H J C D E F P $60 $60 $70 G N $40 A B C D 0 1 2 3 4 0 $90 $100 $110 $90 A B Order Guide 0 A B TOTAL QTY TOTAL VALUE Items in bold are included in the basic price. Selections in italic are available at an additional cost. A B TOTAL QTY TOTAL VALUE Shaded sections indicate typical selections. Example of order code with typical settings: A 0 A PTB330 - Three Sensors Shaded sections indicate typical selections. Example of order code with typical settings: PTB330 - Two Sensors A 0 A 3 Order Guide 0 Items in bold are included in the basic price. Selections in italic are available at an additional cost. 1 2 Digital Barometer with Three Pressure Sensors, Double Redundancy PTB330 - 3 Sensors Class A A 1 Accuracy Class Class B B No display 0 2 Display Graphical LCD with backlight 1 10...35 VDC 3 Power Supply 10...35 VDC with external power on/off triggering 10...35 VDC, 24 VAC, galvanical isolation for outputs (DCDC-1) External US AC-adapter (Not IP65) (MI70USADAPTER) RS-232 only, no analog output 4 Signal Output Analog output 4...20 mA 0...20 mA 0...1 V 0...5 V 0...10 V RS-485 (RS485-1) 500...1100 hPa 5-7 Pressure Range (Same range for all sensors) 50...1100 hPa Class B only Cable bushing for 10...14 mm cable 8 Customer Connection Conduit fitting NPT 1/2" 8-pole M12 connector with 5 m cable (212142) 8-pole M12 connector with screw terminals (212416) D9 connector Not IP65 Barbed fitting 1/8" 9 Pressure Fitting Quick connector 1/8" (19886, 25328 + 25329) Select A only with external AC adapter None 10 Optional Connection Plugged Cable bushing for 10...14 mm cable Conduit fitting NPT 1/2" Normal mounting 11 Installation Adapter plate (for replacing PTB220) (214829) Pole installation kit (215108) Pole installation kit with Rain Shield (215109) DIN rail kit (215094) ISO 9001 compliant factory calibration / No calibration contract 12 Calibration (Separate order form required) ISO/IEC 17025 Accredited calibration 13 Service contract No Service Contract No User's Guide 14 User's Guide language English B PRICE $40 $60 $90 $90 A H H H C G Accessories to be ordered separately. Definitions: Interface cables Serial Interface Cable Software Interface Kit (MI70LINK + serial interface cable) USB-RJ45 Serial Connection Cable MI70LINK software for Windows® + USB-RJ45 Serial Connection Cable B 0 A Order Code: 19446ZZ 215005 219685 219916 0 B PRICE $40 $60 $90 $90 209 www.vaisala.com GMW116 Carbon Dioxide and Temperature Transmitter for Ventilation Control The Vaisala CARBOCAP® Carbon Dioxide and Temperature Transmitter GMW116. Features/Benefits ▪ ▪ ▪ Compact dual-parameter transmitter: measures both CO2 and T Incorporates Vaisala CARBOCAP®, the silicon based NDIR sensor with unique internal referencing Advanced, single-beam, dual wavelength measurement with no moving parts ▪ ▪ Excellent long-term stability ▪ No need for temperature compensation Ideal for ventilation control in all types of occupied spaces including those with aroundthe-clock occupancy The Vaisala CARBOCAP® Carbon Dioxide and Temperature Transmitter GMW116 is the compact-size transmitter that measures both carbon dioxide and temperature. The sensor is accurate and durable and it has an excellent long-term stability, which decreases maintenance. The excellent performance of the Vaisala CARBOCAP® sensors results largely from the stable reference provided by the electrically tunable Fabry-Perot Interferometer (FPI). In buildings with around-theclock occupancy (e.g. hospitals, work-places, residential buildings, retirement homes), the assumed background CO2 level reference is simply not applicable. The true internal reference measurement of Vaisala CARBOCAP® CO2 transmitters provides years of stable CO2 measurements. The GMW116 Transmitter is designed especially for demand controlled ventilation applications with CO2 measurement range of 0 … 2000 ppm and temperature range of 0 ... +50 °C. With GMW116 there is no need for temperature compensation. The ideal gas temperature behaviour is taken into account automatically. Technical data Performance Dimensions CO2-measurement range Temperature measurement range Accuracy (including repeatability, nonlinearity and calibration uncertainty) Long-term stability Response time T90 Temperature dependence Pressure dependence, typical Temperature measurement accuracy Warm-up time Product lifetime 0 ... 2000 ppm 0 ... +50 °C ± (2 % of range + 2 % of reading ± 5 % of range/5 years 1 min compensated +0.15 % of reading/hPa ± 0.7 °C at 25 ° 1 min, 10 min for full. specification > 10 years Operating environment Temperature 0 ... +50 °C Humidity 0 ... 85 % RH Pressure 700 ... 1200 hPa Electromagnectic compatibility Complies with EMS standard EN61326-1, Generic Environment Inputs and outputs Operating voltage Power consumption Outputs 24 V (±20 %) AC/DC <2 W 0 … 10 V Housing Material Weight Cover and base colour Fire resistance Ingress protection ABS/PC blend plastics 120 g white RAL 9003 UL94 V0 IP30 For more information, visit www.vaisala.com or contact us at [email protected] Ref. B210872EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice. PTB210 Series Digital Barometers PTB210 Series Digital Barometers Analog Output Serial Output 1 1 Vaisala BAROCAP® Barometric Pressure Transmitter - Analog Output Pressure range 500…1100 hPa 2 Output options 3 Cable length 4 Manual language 2 3 4 PTB210 C 1 PRICE 3 $1,020 800…1060 hPa 4 $1,020 600…1060 hPa 5 $1,020 900…1100 hPa 6 $1,020 0…5 VDC C 0…2.5 VDC D 1.0 m 1 2.0 m 2 $15 ® 1 Vaisala BAROCAP Barometric Pressure Transmitter Accuracy class Class A (only for 500…1100 hPa range) Class B 2 Pressure range 3 Output options 4 Cable length 2 3 4 5 PTB210 PRICE A $1,470 B $1,230 500…1100 hPa (Class A or B) 1 50…1100 hPa (Class B only) 2 Only RS 232C serial communication A RS 485 (and RS 232C) serial communication (* B TTL level (and RS 232C) serial communication (* T $160 $160 1.0 m 1 3.0 m 3 $20 2.0 m 2 5.0 m 4 $40 3.0 m 3 $20 10.0 m 5 $80 5.0 m 4 $40 10.0 m 5 no manual A English M 5 TOTAL Manual language no manual Selections in italic are available at an additional cost. $80 A English B QTY Items in bold are included in the basic price. $15 TOTAL QTY (* The two output protocols cannot be used simultaneously. TOTAL VALUE TOTAL VALUE Shaded sections indicate typical selections. Items in bold are included in the basic price. Selections in italic are available at an additional cost. Example of an order code with typical settings: PTB210 C 3 C 1 M Shaded sections indicate typical selections. Example of an order code with typical settings: Accessories and Spare Parts: Description: Order Code: Static Pressure head Static Pressure head, heated SPH10 SPH20 PRICE PTB210 B Accessories and Spare Parts: 210 1 A 1 B $270 $820 Description: Order Code: Static Pressure head Static Pressure head, heated SPH10 SPH20 PRICE $270 $820 211 PTB110 Barometer PTB330TS Barometric Pressure Transfer Standard 1 2 3 4 5 1 2 3 4 5 Barometer Pressure range PTB110 500…1100 hPa 1 600...1100 hPa 2 3 800...1100 hPa 600...1060 hPa 4 5 800…1060 hPa 0...5 Vdc A Output options B 0...2.5 Vdc Frequency output F Installation Standard installation 0 DIN rail installation kit 1 Pressure fitting Standard A Quick connector with shut-off valve for 1/8" hose B No user's guide A User's guide English B TOTAL QTY Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. TOTAL VALUE Price Vaisala BAROCAP® Barometric Pressure Transfer Standard $950 PTB330TS $3,200 Please, select below a configuration code for the PTB330 Barometer on the first row, for the MI70 Indicator on the second row and optionally for the HMP155 Probe on the third row. PTB330 Digital Barometer for PTB330TS $10 $40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Example of order code with typical settings: PTB110 1 A 0 A B 1 PTB330 A Vaisala BAROCAP® Digital Barometer Class A A Accuracy Class Display No display Power Supply 10...35 VDC Signal Output RS-232 only, no analog output Pressure Range Barometer module 500...1100 hPa 2nd Barometer module No module Barometer module 500...1100 hPa 3rd Barometer module No module Barometer module 500...1100 hPa Customer Connection 8-pole M12 connector Barbed fitting 1/8", one barometer module Pressure Fitting Choose according Barbed fitting 1/8", two barometer modules to selection Barbed fitting 1/8", three barometer modules made above Optional Connection Plugged Installation PTB330TS in weatherproof hard case Calibration ISO 9001 compliant factory calibration / No calibration contract See separate order form Special calibration for PTB330TS No Service Contract Service contract User's Guide language PTB330TS Guide in English Selections in bold are included in the price of the basic version Selections in italic are available at an extra cost 2 0 3 A 4 A 5 H 6 7 8 F 9 10 11 12 13 14 B 5 0 1 Price 0 A A H A H $460 A H $460 F E F G B 5 A X 0 1 Example of order code with typical settings: A 0 A A H PTB330 H H F G B 5 A 0 1 2 3 MI70 Hand-Held Indicator for PTB330TS 1 Vaisala Hand-held Indicator 1 Charger type 2 Installation 3 Accessories MI70 Price 4 Euro AC-adapter US AC-adapter PTB330TS none MI70LINK software with RS232 cable MI70LINK software with USB cable B D 4 0 1 4 $60 $90 Total value Selections in bold are included in the price of the basic version Selections in italic are available at an extra cost Spare parts: MI70 connection cable to HMT330, MMT330, DMT340, HMT100, PTB330 MI70 battery MI70 Example of order code with typical settings: D 4 4 9 10 11 12 13 14 15 Price A 0 $640 $60 $30 Item: 211339 Item: 26755 OPTIONAL (with additional price): HMP155 Humidity and Temperature Probe for PTB330TS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Vaisala HUMICAP® Humidity and Temperature Probe RS485 serial output Probe type RS485 serial output Signal output selection Analog output signal for CH1 None Analog output signal for CH2 None Units Metric Non-metric General purpose Humidity sensor type Composite sensor Heating options None Chemical purge None Manual purge with MI70 (only with composite sensor) Sensor protection Sintered Teflon filter Probe cable length No cable (no counter connector) None (if probe type D selected, please select option A) Additional Temperature probe Additional T-probe with 2m cable Calibration At room temperature MI70 connection cable PC-Accessories Installation PTB330TS (For production use only) 1 2 3 4 HMP155 E E 1 A A 5 6 7 8 A 1 C 4 A 1 A A 1 2 HUMICAP180R HUMICAP180RC 1 2 $60 A 0 4 A 0 A B $160 1 Item:221801 C $60 4 A Total value Selections in bold are included in the price of the basic version Selections in italic are available at an extra cost 212 Example of order code with typical settings: HMP155 E 1 A A 2 1 A 0 A 0 A 1 C 4 A 213 WMT52 Ultrasonic Wind Speed and Direction Sensor WXT520 Weather Transmitter 1 WMT52 Vaisala WINDCAP® Ultrasonic Wind Sensor Wind speed and direction A 1 Measurement parameters SDI-12 v 1.3, 1200 baud, 7,E,1 2 Communication interface 3 RS-232, Standard ASCII auto, 19200 baud,8,N,1 RS-485, Standard ASCII polled, 19200 baud, 8,N,1 RS-422, Standard ASCII auto, 19200 baud, 8,N,1 RS-422 NMEA 0183 v3.0, 4800 baud, 8,N,1 USB/RS-232, 1.4 m USB cable, ASCII auto, 19200 baud,8,N,1 (220782) USB/RS-485, 1.4 m USB cable, ASCII polled, 19200 baud, 8,N,1 (220782) None 4 Enhancements Heating No connector, bushing & grounding accessories 5 Connector 6 Cable 7 Installation accessories 8 Supporting software 9 Manual 10 Packing 2 3 4 5 6 7 8 9 1 10 PRICE $1,080 A A A A A A A A B C D E F G $110 $110 0 1 8-pin M12 male connector and bushing & grounding accessories No Cable Shielded 2 meters long 8-pin M12 cable (222287) Shielded 10 meters long 8-pin M12 cable (222288) Shielded 40 meters long 14-pin cable, open end wires (217020) Shielded 10 meters long 8-pin M12 cable, connectors on both ends (215952) None Mounting kit improves classification from IP65 to IP66 (212792) (212793) Bird spike Mounting kit and Bird spike improves classification from IP65 to IP66 (212792 + 212793) None Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable A B A B C D E Wsd+RH+T+P+R SDI-12 v 1.3, 1200 baud, 7,E,1 0 1 2 3 RS-232, Standard ASCII auto, 19200 baud,8,N,1 RS-485, Standard ASCII polled, 19200 baud, 8,N,1 RS-422, Standard ASCII auto, 19200 baud, 8,N,1 RS-422 NMEA 0183 v3.0, 4800 baud, 8,N,1 USB/RS-232, 1.4 m USB cable, ASCII auto, 19200 baud,8,N,1 (220782) USB/RS-485, 1.4 m USB cable, ASCII polled, 19200 baud, 8,N,1 (220782) None No connector, bushing & grounding accessories 8-pin M12 male connector and bushing & grounding accessories $55 6 Cable No Cable Shielded 2 mete rs long 8-pin M12 cable (222287) $90 $120 $200 0 1 9 Manual language $150 10 Packing A B Standard 8 Supporting software 4 5 6 7 9 A B C D E A A F G Price $110 $110 0 $90 A B $55 A Shielded 10 meters long 8-pin M12 cable (222288) Shielded 40 meters long 14-pin cable, open end wires (217020) Shielded 10 meters long 8-pin M12 cable, connectors on both ends (215952) None Mounting kit improves classification from IP65 to IP66 (212792) (212793) Bird spike improves classification from IP65 to IP66 (212792+ 212793) Mounting kit and Bird spike None B C D E $100 $160 $300 $210 0 1 2 3 $90 $120 $200 0 Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable No manual English Standard QTY TOTAL VALUE 10 0 $2,150 A A A A A 1 $150 A B 0 TOTAL Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. 0 TOTAL 8 1 5 Connector 7 Installation accessories 3 A $90 $100 $160 $300 $210 No manual English Example of order code with typical settings: WMT52 A A A 0 A A 1 QTY TOTAL VALUE Example of order code with typical settings: WXT520 A A A 0 A A 1 1 B 0 WXT520 Spare parts & Accessories 1 B 0 220614 218817SP WXTBOTTOMSP WXT52 Spare parts & Accessories Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable WMT52 Bottom assembly (with BIF card, M12 connector, short screws. O-rings) $180 $200 WMT50/52 Spare parts & Accessories 220782 222287 222288 217020 215952 222109 212792 WSP150 WSP152 212793 4 Enhancements 2 WXT520 Heating for wind and rain measurements Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. 220614 WMTBOTTOMSP Weather Transmitter 1 Measurement parameters 2 Communication interface 3 USB RS-232/485, 1.4 meters USB / M12 cable Shielded 2 meters long 8-pin M12 cable Shielded 10meters long 8-pin M12 cable Shielded 40 meters long 14-pin cable, open end wires 10 meters long 8-pin M12 cable, connectors on both ends Bushing & grounding accessory kit Mounting kit (improves classification from IP65 to IP66) Surge protector, no connectors Surge protector for host PC (e.g. USB connection) inc. M12 connectors. Suitable with 220782 and 215952. Bird kit $140 $140 $210 $400 $270 $30 $120 $300 $350 $140 Service Pack 2: Vaisala Configuration Tool for Windows, USB Service cable WXT520 Radiation shield set WXT520 Bottom assembly (with BIF card, M12 connector, screws w. O-rings) $180 $175 $200 WXT510/520 Spare parts & Accessories 220782 222287 222288 217020 215952 WXTPTUSP 222109 212792 WSP150 WSP152 212793 USB RS-232/485, 1.4 meters USB / M12 cable Shielded 2 meters long 8-pin M12 cable Shielded 10meters long 8-pin M12 cable Shielded 40 meters long 14-pin cable, open end wires 10 meters long 8-pin M12 cable, connectors on both ends WXT PTU module Bushing & grounding accessory kit Mounting kit (improves classification from IP65 to IP66) Surge protector, no connectors Surge protector for host PC (e.g. USB connection) inc. M12 connectors. Suitable with 220782 and 215952. Bird kit $140 $140 $210 $400 $270 $210 $30 $120 $300 $350 $140 WXT510 Spare parts & Accessories 215194 221523 Service Pack 1: Vaisala Configuration Tool, Weather Measurements (software and RS-232 WXT510 service cable) M8 adapter to WXT510 Service connector (use with Service pack 2) $90 $60 WMT50 Spare parts & Accessories 215194 221523 214 Service Pack 1: Vaisala Configuration Tool, Weather Measurements (software and RS-232 WXT510 service cable) M8 adapter to WXT510 Service connector (use with Service pack 2) $90 $60 215 Non-configurable Instrument price list HUMIDITY AND TEMPERATURE INSTRUMENTS WA15 Wind Set 1 3 PRICE A B C D Accessories Sensors Vaisala Wind Measurement Set WA15 no sensors wind speed sensor WAA151 only wind direction sensor WAV151 only wind speed and direction sensors WAA151 and WAV151 2 Crossarm or transmitter no crossarm or wind transmitter (signal pass-through) and cable crossarm with termination box WAC151 crossarm with termination box WAC151, 16-lead signal cable crossarm with termination box WAC151, 6-lead power cable crossarm with termination box WAC151, 16-lead signal and 6-lead power cable (current loop output) crossarm and analog transmitter WAT12 crossarm and analog transmitter WAT12, 6-lead cable for signal and power (WAC155) Crossarm and serial RS-485 transmitter WAC155 (WAC155B) Serial RS-485 transmitter WAC155CB card only 3 Power supply no power supply power supply WHP151 1 2 $550 $590 $1,130 1 2 3 4 5 6 7 8 9 $440 $560 $560 $650 $730 $810 $790 $260 A B TOTAL QTY TOTAL VALUE Selections in bold text are included in the price of basic version. $580 Portables: HM34 Pocket-size relative humidity and temperature meter…………………………………….. $535 Duct and Wall Mount: HMD60Y Humidity and temperature 2-wire transmitter for duct mounting, 4 to 20 mA outputs…. $525 HMD60U Humidity transmitter for duct mounting; same as HMD60Y but humidity only…………. $420 HMW60Y Humidity and temperature 2-wire transmitter for wall mounting, 4 to 20 mA outputs…. $480 HMW60U Humidity transmitter for wall mounting; same as HMW 60Y but humidity only………… $360 HMD70Y Humidity and temperature 3-wire transmitter for duct mounting with voltage outputs… $525 HMD70U Humidity transmitter for duct mounting; same as HMD70Y, but humidity only………… $420 HMW70Y Humidity and temperature transmitter for wall mounting with voltage outputs…………. $480 HMW70U Humidity transmitter for wall mounting; same as HMW70Y but humidity only…………. $360 Selections in italic are available at extra cost. Shaded sections indicate typical selections. Temperature-Only: Example of order code with typical settings: WA15 D Accessories and Spare Parts: Description Set of bearings and gasket Cup assembly Thermostat Switch Option (not included in AWAT12 if ordered separately) Connector WAA151, WAA252 Connector WAV151, WAV252 Outdoor Signal Cable for WA-sensor, 10m (16-lead) Outdoor Heating Power Cable, 10m (6-lead) Vaisala Surge Protector Order Code 16644WA 7150WA 16923WA 1394 1395 ZZ45048 ZZ45049 WSP150 5 B PRICE $45 $60 $70 $35 $35 $125 $85 $300 HMD60T Temperature two-wire transmitter for duct mounting, 4 to 20mA outputs………………. $410 HMW60T Temperature two-wire transmitter for wall mounting, 4 to 20 mA outputs………………. $360 HMD70T Temperature three-wire transmitter for duct mounting with voltage outputs…………… $440 HMW70T Temperature three-wire transmitter for wall mounting with voltage outputs……………. $360 HMD60YO Humidity and temperature 2-wire transmitter for use outdoors 4 to 20 mA outputs. ….. $760 HMD60UO Humidity 2-wire transmitter for use outdoors; same as HMD60YO but humidity only… $640 HMD70YO Humidity and temperature 3-wire transmitter for use outdoors with voltage outputs…. $840 HMD70UO Humidity 3-wire transmitter for use outdoors. Same as HMD70YO, but humidity only.. $670 HMD40Y Humidity and temperature 2-wire transmitter for duct mounting, 4 to 20 mA outputs…. $260 HMD40U Humidity transmitter for duct mounting: same as HMD40Y, but humidity only………… $190 HMW40Y Humidity and temperature 2-wire transmitter for wall mounting, 4 to 20 mA outputs…. $240 HMW40U Humidity transmitter for wall mounting; same as HMW40Y, but humidity only………… $180 HMD50Y Humidity and temperature 3-wire transmitter for duct mounting with voltage outputs. .. $260 HMD50U Humidity transmitter for duct mounting; same as HMD50Y, but humidity only………… $190 HMW50Y Humidity and temperature 3-wire transmitter for wall mounting with voltage outputs…. $240 HMW50U Humidity transmitter for wall mounting; same as HMW 50Y, but humidity only………... $180 Outdoor Use: Calibration-Free: SOLAR RADIATION AND PRECIPITATION SHIELDS 216 DTR503A Solar radiation and precipitation shield, 12 plate………………………………………….. $310 DTR502B Solar radiation and precipitation shield, 9 plate……………………………………………. $310 217 Vaisala Contact Information HMT300TMK for Power Turbine Complete Solutions Consists of: Transmitter: HMT3307S0C021XXAA200F0EAABAA1 X = -49 to 167°F dewpoint Installation Kit: HMT300TMK1B1 EUROPE Total Price: $3985 CARBON DIOXIDE (CO2) INSTRUMENTS GMD20 Carbon dioxide transmitter for duct mounting……………………………………………… $360 GMD20D Same as GMD20 plus local display and relay……………………………………………... $410 GMW21 Carbon dioxide transmitter for wall mounting……………………………………………… $330 GMW21D Same as GMW21 plus local display and relay…………………………………………….. $380 GMA20T Analog temperature option for GMW21 with 0 to 10V output……………………………. $60 GMI21 Local display and relay option for GM20 series transmitters…………………………….. $80 GMR20 Relay option for GM20 series transmitters…………………………………………………. $60 19040GM Serial COM adapter for calibrating GM20 series transmitters……..…………………….. $100 GML20 Lonworks module for GM20 series transmitters…………………………………………… $170 GML20T Lonworks module including temperature for GMW21…………………………………….. $240 GMW115 Carbon dioxide transmitter for wall mounting……………………………………………… $300 STATIC PRESSURE HEADS SPH10 Static pressure head………………………………………………………………………….. $270 SPH20 Static pressure head, heated………………………………………………………………… $820 OEM Products, Call 1-888-VAISALA (824-7252) for pricing HMM210 Humidity modules for environmental chambers. HMM100 Humidity modules for environmental chambers. HMT310 Humidity and temperature transmitters with small size and 6 probe choices. DMT142 Miniature dewpoint transmitter. MMT310 Moisture and temperature transmitters for oil. MMT162 Compact moisture in oil and temperature transmitter. GMM111 Carbon dioxide module with 0-5, 0-10 and 0-20% measuring ranges. GMM112 Carbon dioxide module for HVAC applications. GMM20W Carbon dioxide module. GMM220 Carbon dioxide module for demanding applications. FINLAND Vaisala Oyj P.O.Box 26 FI-00421 Helsinki FINLAND Tel. +358 9 894 91 Fax +358 9 8949 2485 [email protected] www.vaisala.com BENELUX Contact: Bonn Office Adenauerallee 15 D-53111 Bonn GERMANY Tel. +49 228 24971 23 Fax +49 228 24971 11 Toll free Netherlands : 00800 -282 472 52 Toll free Belgium: 0800 17 200 [email protected] www.vaisala.nl www.vaisala.be FRANCE Vaisala SAS Marseille Office 2, rue de Beausset F-13001 Marseille FRANCE Tel. +33 4 88 66 17 51 + 0800 67 67 26 [email protected] www.vaisala.fr Vaisala SAS Paris Office 2, rue Stéphenson F-78181 Saint-Quentin-en-Yvelines Cedex FRANCE Tel. +33 1 3057 7342 Fax. +33 1 3096 0858 + 0800 67 67 26 [email protected] www.vaisala.fr 218 GERMANY Vaisala GmbH Bonn Office Adenauerallee 15 D-53111 Bonn GERMANY Tel. +49 228 24971 0 Fax. +49 228 24971 11 National: 0800VAISALA [email protected] www.vaisala.de Vaisala Oyj Stockholm Office Johanneslundsvägen 2 S-194 61 Upplands Väsby SWEDEN Tel. +46 8 750 94 20 Fax. +46 200 8490 849 National (tel.): 0200 848 848 National (fax.): 0200 849 849 [email protected] www.vaisala.se Vaisala GmbH Hamburg Office Schnackenburgallee 41D D-22525 Hamburg GERMANY Tel. +49 40 8390 3160 Fax. +49 40 8390 3110 National: 0800VAISALA [email protected] www.vaisala.de SWITZERLAND Contact: Bonn Office Adenauerallee 15 D-53111 Bonn GERMANY Tel. +49 228 24971 0 Fax. +49 228 24971 11 [email protected] www.vaisala.de Vaisala GmbH Uhingen Office Bahnhofstraße 3 D-73066 Uhingen GERMANY Tel. +49 7161 65494 40 Fax. +49 7161 65494 50 National: 0800VAISALA [email protected] www.vaisala.de UNITED KINGDOM Vaisala Ltd Birmingham Office Vaisala House 349 Bristol Road Birmingham B5 7SW UNITED KINGDOM Tel. +44 121 683 1257 Fax +44 1638 576 240 [email protected] www.vaisala.com SWEDEN Vaisala Oyj Malmö Office Drottninggatan 1 D S-212 11 Malmö SWEDEN Tel. +46 40 298 991 Fax +46 40 298 992 National (tel.): 0200 848 848 National (fax.): 0200 849 849 [email protected] www.vaisala.se Vaisala Ltd Newmarket Office Unit 9, Swan Lane Exning Newmarket Suffolk CB8 7FN UNITED KINGDOM Tel. +44 1638 576 200 Fax +44 1638 576 240 [email protected] www.vaisala.com NORTH AMERICA Vaisala Inc. Boston Office 10-D Gill Street Woburn, MA 01801 USA Tel. +1 781 933 4500 Toll free 1-888-VAISALA (824-7252) Fax. +1 781 933 8029 [email protected] www.vaisala.com ASIA AND PACIFIC AUSTRALIA Vaisala Pty Ltd Melbourne Office 3 Guest Street Hawthorn, VIC 3122 AUSTRALIA Tel: +61 3 9815 6700 Fax: +61 3 9815 6799 Freecall: 1800 335 840 [email protected] vaisala.com www.vaisala.com CHINA Vaisala China Ltd Beijing Office Floor 2, EAS Building No.21, Xiao Yun Road, Dongsanhuan Beilu CHINA Tel. +86 10 85261199 Fax. +86 10 85261155 [email protected] cn.vaisala.com JAPAN Vaisala KK Tokyo Office 42 Kagurazaka 6-Chome Shinjuku-Ku Tokyo 162-0825 JAPAN Tel. + 81 3 3266 9611 Fax. + 81 3 3266 9610 [email protected] www.vaisala.co.jp 219 HVAC LUBRICATION POWER GENERATION COMPRESSED AIR BUILDING AUTOMATION LIFE SCIENCE ACCURATE INSTRUMENTS HIGH-TECH CLEANROOMS CHAMBERS RELIABLE MEASUREMENTS SERVICES www.vaisala.com www.vaisala.com For more information, visit www.vaisala.com or contact us at [email protected] Ref. B211016EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement