RLM W14
Quick start guide
Mounting the lens
LOCK
OPEN
INSTALL SAFETY CABLE
Removal of lens protection sponge
INSTALL
LOCK
OPEN
LOCK
OPEN
LOCK
OPEN
Click
Call for support: USA +1 866 374 7878
EMEA +32 56 368609
APAC +86 400 88 22726
Follow the drawing to install the lens Carefully align the connectors while installing the lens and fix the safety cable on the machine
Follow the drawing to Tie up the lever for lock the lens
Press button then press down the lever
REMOVE
Pull out the lens
POWER
Displays the projector’s power status
ERROR
Displays the cause of problem
(i.e. temperature, fan, lamp or system) that has led to projector malfunction.
STAND BY
The indicator that shows the projector’s standby status.
STBY
Use this button to start up or shut down the projector.
Buttons and LEDs
ON
MENU
ERROR
STBY
STBY INPUTS
MENU
Displays or hides the OSD adjustment screen
ENTER
Press this button to confirm selection of OSD item; you can choose from “Select Item” or access “Sub Menu” configurations.
buttons
Use these buttons to scroll, configure or adjust items on the OSD or toggle between different images.
INPUT
Used to toggle between different input signal source.
Refer to Chapter VI → Signal
Source Selection for more details.
LED indication chart
Standby
Lamp is approaching end of life
Cooling / Warm up
Power on / Normal
Lamp failure
Lamp door open
Fan failure
Overheating
System error
Blue
(STANDBY)
Green
(ON)
Red
(ERROR)
-
-
-
Quick setup and operation
The following summarizes RLM W14 setup and operation. For errorfree installation always refer to the listed section in the User Guide.
1 Connect power. Ensure that the power (90-250 V @ 50/60hz) is properly connected to the RLM W14.
2
3
Connect available sources to the appropriate input terminal.
Power on. Turn the mains switch to on.
4
5
Standby LED (blue) must be constantly lit.
Start up the unit by pressing the STBY button.
6 Warm up of the unit takes approx. 45 sec till image appears.
7
Image of the source should appear after 15 seconds if the unit is in full auto mode.
8 Adjust the lens settings by pressing the ENTER button for
ZOOM and FOCUS adjust. Toggle to SHIFT by pressing ENTER again. Lens function can also be found in the CONFIGURATION menu.
9 Factory Reset can be executed in order to put the unit in the full auto mode. Factory reset can be found in the SERVICE menu.
Press execute and wait 30 sec.
10
After factory reset the projectors needs some time to scan the inputs before displaying the source.
11
Auto source can be switched off in the CONTROL menu. The manual selection can be done via menu or other control systems.
12 Alignment the unit is set as standard in table front projection mode. Change the projector set up in the Alignment menu.
13
If geometrical distortion occurs (H/V keystone), this can be corrected with Keystone in the Alignment menu.
14
Tuning the image can be done in the IMAGE menu. Default values are 100.
15
Picture-in-Picture control can be done in the LAYOUT menu.
16 Lamp management in the LAMP menu.
17
Switching off the unit can be done by pressing the STBY button for 2 sec. or the button for 2 sec. on the remote control.
Printed on FSC certified paper (www.fsc.org)
IMPORTANT:
• Remove the lens before transporting the projector.
• To save lamp lifetime, first switch the projector to standby mode and wait two minutes, then switch off the main power.
• Ensure that the projector is operating with clean filters.
• Do not block the ventilation in and outlets
• Using the projector in a non recommended tilt angle will reduce the lifetime of the lamps or create unexpected behavior of the unit.
• Laser light can cause severe damage to the DMD.
This damage is not covered by warranty.
DNV-COC-000020
RLM W14 Quickstart guide dec09outl.indd 1 04/08/14 15:30
RLM W14
Quick start guide
6
7
1
3
Using the remote control
1 Switch on the projector
2
2 Switch off the projector. Press for 2 sec
4
1
INPUT
2 3
5
3
Source selection hot key. Define Hot Keys in the control menu
4 Navigation key. Enter key for confirmation
4
MENU
PAUSE
1
PHASE
PIP
TEXT
COLOR
ASPECT
RATIO
AUTO IMAGE
SHARPN
TINT
SWAP ADDRESS
5
5 Aspect ratio switch
6 Activate menu or return key
7
Settings
Pause: picture mute (shutter close)
Text: deactivate or activate the On Screen Text
Auto image: activate the auto image adjustment
Contrast: high lights adjust
Brightness: low lights adjust
Sharpness: increase edge detail
Phase: adjust phase (analog signals only)
Color: color saturation
Tint: tint adjust (NTSC only)
PIP: activate selected Picture-in-Picture
SWAP: swap PiP and main image
Address: change the remote control address to 1 or 2.
Press address and enter for 5 sec.
Menu structure
INPUT
Input Selection
Input Configuration
Input Locking
Auto Power Off
Auto Power On
No Signal
Auto Image Adjust
IMAGE
Contrast
Brightness
Sharpness
Noise Reduction
Color Temperature
Input Balance
Aspect Ratio
Timings
Auto Image
LAYOUT
Zoom
Main Select
PIP Select
PIP Position
PIP
Connector panel
Support Full HD uncompressed video
Use SDI/HDSDI/3G for professional equipment
External RS232 comm.
Trigger voltage can control e.g. a screen or curtains
200mA
Use HDMI for
e.g. PC or
Blu-ray player
Use D15 input for PC
Use RCA inputs for component signals
External control over IP for e.g.
Projector Toolset or web browser
Input/Output connectionfor
3D Sync singal
Use BNC inputs for RGBHV and component signals
Dual DVI input for 3D source
PiP/main source availability
HDBaseT
HDMI
VGA
YUV1
RGBHV/YUV2
SDI/HDSDI/3G
Source availabe
HDBaseT HDMI
-
-
-
LAMPS
Mode
Lamps
High Altitude Mode
Power
Lamp1 Status
Lamp2 Status
Lamp1 Run Time
Lamp2 Run Time
ALIGNMENT
Rear Projection
Ceiling Mode
Lens Control
Lens To Midposition
Lens Memory
Lens Calibration
Dynamic Contrast
Gamma
Internal Patterns
Color Space
Custom Color Space
Warp
Blanking
ScenergiX
-
-
VGA
Main select
YUV1
-
RGBHV/
YUV2
SDI/
HDSDI/
3G
-
-
-
-
-
3D-DVI
-
-
-
-
-
-
- source not availabe
CONTROL
IR Address
Eco Network Power
Network
Menu Position
Start Up Logo
Start Up Chime
Button 1
Button 2
Button 3
Button 4
Button 5
Trigger 1
Trigger 2
Auto Source
Language
SERVICE
Model
Serial Number
Software Version
Active/ PIP Source
Pixel Clock
Signal Format
H/V Refresh Rate
Lamp1 Run Time
Lamp2 Run Time
Lamp Hour Reset
Projector Run Time
Blue Only
Factory Reset
RLM W14 Quickstart guide dec09outl.indd 2 04/08/14 15:30