Multitech MTCBA-C-IP-N1 Specifications

Add to my manuals
253 Pages

advertisement

Multitech MTCBA-C-IP-N1 Specifications | Manualzz

Wireless EDGE Modems

MultiModem

MultiModem

EDGE with Bluetooth Interface

(MTCBA-E-B)

MultiModem

EDGE with Ethernet Interface

(MTCBA-E-EN)

EDGE with GPS Functionality (

MTCBA-E-GP)

MultiModem

MultiModem

EDGE

(MTCBA-E)

EDGE with USB

Embedded Wireless SocketModem

(MTCBA-E-U)

EDGE

(MTSMC-E)

AT Commands

Fax Commands

IP Commands

SIM Commands

Audio Commands

Reference Guide

Copyright and Technical Support

AT Commands for Multi-Tech EDGE Modems

MultiModem  EDGE with Bluetooth Interface (MTCBA-E-B)

MultiModem  EDGE with Ethernet Interface (MTCBA-E-EN)

MultiModem  EDGE with GPS Functionality (MTCBA-E-GP)

MultiModem  EDGE (MTCBA-E)

MultiModem  EDGE with USB (MTCBA-E-U)

Embedded Wireless SocketModem  EDGE (MTSMC-E)

Reference Guide

PN S000371B, Revision B

Copyright

This publication may not be reproduced, in whole or in part, without prior expressed written permission from

Multi-Tech Systems, Inc. All rights reserved. Copyright © 2005-2006, by Multi-Tech Systems, Inc.

Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose. Furthermore,

Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.

Revisions

Revision

A 07/07/05

B 01/24/06 Added trademarks and registered trademarks to the cover page. Added a product list and a command list. Removed the statement in 18.6 that the setting is stored non-volatile.

Changed light blue non-hyperlinked text to black.

Trademarks

MultiModem, SocketModem, and the Multi-Tech logo are registered trademarks of Multi-Tech Systems, Inc.

World Headquarters

Multi-Tech Systems, Inc.

2205 Woodale Drive

Mounds View, Minnesota 55112

Phone: 763-785-3500 or 800-328-9717

Fax: 763-785-9874

Technical Support

Country

France:

India:

U.K.:

U.S. and Canada:

Rest of the World:

Internet Address:

By Email [email protected]

[email protected]

[email protected]

[email protected]

By Phone

972-2439 [email protected]

(763) http://www.multitech.com

(33) 1-64 61 09 81

91 (124) 6340778

(44) 118 959 7774

(800)

717-5863

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 2

Table of Contents

Table of Contents

Chapter 1. Introduction..............................................................................................................................................9

1.1 Scope of the Document......................................................................................................................................9

1.2 Related Documents............................................................................................................................................9

1.3 Document Conventions......................................................................................................................................9

1.4 AT Command Syntax .......................................................................................................................................10

1.4.1 Using Parameters ......................................................................................................................................10

1.4.2 Combining AT Commands on the Same Command Line...........................................................................10

1.5 Supported Character Sets................................................................................................................................11

1.5.1 GSM Alphabet Tables and UCS2 Character Values ..................................................................................12

1.5.2 UCS2 and GSM Data Coding and Conversion for SMS Text Mode...........................................................14

1.6 Serial Interface Flow Control ............................................................................................................................16

1.6.1 Software Flow Control (XON/OFF Handshake) .........................................................................................16

1.6.2 Hardware Flow Control (RTS/CTS Handshake).........................................................................................16

1.7 Unsolicited Result Code Presentation..............................................................................................................16

1.7.1 Communication between Customer Application and Multi-Tech Wireless Modem ....................................17

1.8 Common PCN Handset Specification (CPHS) .................................................................................................18

1.9 Errors and Messages .......................................................................................................................................18

Chapter 2. Configuration Commands.....................................................................................................................19

2.1 AT&F Set All Current Parameters to Manufacturer Defaults ..........................................................................19

2.2 AT&V Display Current Configuration..............................................................................................................19

2.2.1 AT&V Responses.......................................................................................................................................20

2.3 AT&W Stores Current Configuration ..............................................................................................................20

2.4 ATQ Set Result Code Presentation Mode......................................................................................................20

2.5 ATV Set Result Code Format Mode...............................................................................................................21

2.5.1 Verbose and Numeric Result Codes ..........................................................................................................21

2.6 ATX Set CONNECT Result Code Format and Call Monitoring ......................................................................22

2.7 AT\ V Set CONNECT Result Code Format ....................................................................................................22

2.8 ATZ Set all Current Parameters to User Defined Profile ................................................................................22

2.9 AT+CFUN Set Phone Functionality................................................................................................................23

2.9.1 Wake up the ME from SLEEP Mode ..........................................................................................................24

2.10 AT^SMSO Switch off Mobile Station ............................................................................................................25

2.11 AT+GCAP Request Complete TA Capabilities List ......................................................................................25

2.12 AT+CMEE Mobile Equipment Error Message Format..................................................................................25

2.12.1 CME/CMS Error Code Overview................................................................................................................26

2.13 AT+CSCS Select TE Character Set .............................................................................................................29

2.14 AT^SCFG Extended Configuration Settings.................................................................................................29

Chapter 3. Status Control Commands ...................................................................................................................36

3.1 AT+CMER Mobile Equipment Event Reporting..............................................................................................36

3.2 AT+CIND Indicator control .............................................................................................................................37

3.3 AT^SIND Extended Indicator Control .............................................................................................................39

3.4 AT+CEER Extended Error Report..................................................................................................................43

3.4.1 Cause Location ID for the Extended Error Report......................................................................................44

3.4.2 GSM Release Cause for L3 Radio Resource (RR) ....................................................................................44

3.4.3 GSM Release Cause for Mobility Management (MM)..................................................................................45

3.4.4 GSM Release Cause for L3 Call Control (CC) .............................................................................................46

3.4.5 GSM Release Cause for Supplementary Service Call ...............................................................................47

3.4.6 GSM Cause for L3 Protocol Module or Other Local Cause........................................................................48

3.4.7 Release Cause for GPRS API ...................................................................................................................48

3.4.8 Release Cause for PPP/IP-Stack...............................................................................................................48

3.5 ATS18 Extended Call Release Report ...........................................................................................................49

3.6 AT+CPAS Mobile Equipment Activity Status..................................................................................................49

3.7 AT+WS46 Select Wireless Network ...............................................................................................................50

Chapter 4. Serial Interface Control Commands.....................................................................................................51

4.1 AT\Q Flow Control..........................................................................................................................................51

4.2 AT&C Set Circuit Data Carrier Detect (DCD) Function Mode.........................................................................51

4.3 AT&D Set Circuit Data Terminal Ready (DTR) Function Mode ......................................................................51

4.4 AT&S Set Circuit DSR Function Mode ...........................................................................................................52

4.5 ATE Enable Command Echo .........................................................................................................................52

4.6 AT+ICF Serial Interface Character Framing...................................................................................................52

4.7 AT+IFC Set Flow Control Separately for Data Directions...............................................................................53

4.8 AT+ILRR Set TE-TA Local Rate Reporting ....................................................................................................53

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 3

Table of Contents

4.9 AT+IPR Set Fixed Local Rate ........................................................................................................................54

4.9.1 Autobauding...............................................................................................................................................55

4.10 AT+CMUX Enter Multiplex Mode .................................................................................................................56

4.10.1 Restrictions on Multiplex Mode ................................................................................................................56

4.11 AT+STPB Transmit Parity Bit (for 7E1 & 7O1 Only).....................................................................................58

Chapter 5. Security Commands ..............................................................................................................................59

5.1 AT+CPIN PIN Authentication .........................................................................................................................59

5.1.1 What to Do if PIN or Password Authentication Fails? ................................................................................60

5.2 AT+CPIN2 PIN2 Authentication .....................................................................................................................61

5.3 AT^SPIC Display PIN Counter .......................................................................................................................62

5.4 AT+CLCK Facility Lock ..................................................................................................................................65

5.5 AT^SLCK Facility Lock...................................................................................................................................68

5.6 AT+CPWD Change Password .......................................................................................................................68

5.7 AT^SPWD Change Password........................................................................................................................70

Chapter 6. Identification Commands......................................................................................................................71

6.1 ATI Display Product Identification Information................................................................................................71

6.2 AT+CGMI Request Manufacturer Identification..............................................................................................71

6.3 AT+GMI Request Manufacturer Identification ................................................................................................71

6.4 AT+CGMM Request Model Identification .......................................................................................................71

6.5 AT+GMM Request Model Identification............................................................................................................71

6.6 AT+CGMR Request Revision Identification ...................................................................................................72

6.7 AT+GMR Request Revision Identification ......................................................................................................72

6.8 AT+CGSN Request International Mobile Equipment Identity .........................................................................72

6.9 AT+GSN Request International Mobile Equipment Identity............................................................................72

6.10 AT+CIMI Request International Mobile Subscriber Identity..........................................................................73

Chapter 7. Call-Related Commands .......................................................................................................................74

7.1 Call Status Information.....................................................................................................................................74

7.2 ATA Answer a Call .........................................................................................................................................75

7.3 ATD Mobile Originated Call to a Specified Number .......................................................................................75

7.4 ATD><mem><n> Mobile Originated Call Using Specific Memory and Index Number.....................................77

7.5 ATD><n> Mobile Originated Call from Active Memory Using Index Number ..................................................78

7.6 ATD><str> Mobile Originated Call from Active Memory Using Corresponding Field......................................78

7.7 ATDI Mobile Originated Call to ISDN Number................................................................................................79

7.8 ATDL Redial Last Number Used ....................................................................................................................79

7.9 ATH Disconnect Existing Connection.............................................................................................................79

7.10 AT+CHUP Hang Up Call ..............................................................................................................................80

7.11 AT^SHUP Hang Up Call(s) Indicating a Specific GSM04.08 Release Cause ..............................................80

7.12 ATS0 Set Number of Rings before Automatically Answering a Call.............................................................81

7.13 ATS6 Set Pause before Blind Dialing...........................................................................................................82

7.14 ATS7 Set Number of Seconds to Wait for Connection Completion..............................................................82

7.15 ATS8 Set Number of Seconds to Wait for Comma Dialing Modifier.............................................................82

7.16 ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier .................................................83

7.17

ATO Switch from Command Mode to Data Mode / PPP Online Mode.........................................................83

7.18 +++ Switch from Data Mode to Command Mode ..........................................................................................83

7.19 AT+CBST Select Bearer Service Type ........................................................................................................84

7.20 AT+CRLP Select Radio Link Protocol Parameters for Originated Non-Transparent Data Calls ..................84

7.21 AT+CLCC List Current Calls of ME ..............................................................................................................85

7.22 AT^SLCC List Current Calls of ME...............................................................................................................86

7.23 AT+CR Service Reporting Control ...............................................................................................................89

7.24 AT+CRC Set Cellular Result Codes for Incoming Call Indication.................................................................90

7.25 AT+CSNS Single Numbering Scheme .........................................................................................................90

7.26

AT^SCNI List Call Number Information ........................................................................................................91

7.27 AT^SLCD Display Last Call Duration ...........................................................................................................91

7.28 AT^STCD Display Total Call Duration..........................................................................................................91

7.29 ATP Select Pulse Dialing .............................................................................................................................92

7.30 ATT Select Tone Dialing ..............................................................................................................................92

Chapter 8. Network Service Commands ................................................................................................................93

8.1 AT+COPN Read Operator Names .................................................................................................................93

8.2 AT+COPS Operator Selection .......................................................................................................................93

8.3 AT^SOPS Extended Operator Selection ........................................................................................................95

8.4 AT+CREG Network Registration ....................................................................................................................96

8.5 AT+CSQ Signal Quality..................................................................................................................................97

8.6 AT^SMONC Cell Monitoring...........................................................................................................................98

8.7 AT^SMOND Cell Monitoring...........................................................................................................................99

8.8 AT^MONI Monitor Idle Mode and Dedicated Mode ......................................................................................100

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 4

Table of Contents

8.8.1 AT^MONI Responses ..............................................................................................................................101

8.8.2 Service States..........................................................................................................................................101

8.9 AT^MONP Monitor Neighbour Cells.............................................................................................................102

8.9.1 AT^MONP Responses .............................................................................................................................102

8.10 AT^SMONG GPRS Monitor .......................................................................................................................103

8.10.1 AT^SMONG Cell Info Table ...................................................................................................................103

8.11 AT^SALS Alternate Line Service................................................................................................................104

8.12

AT^SHOM Display Homezone ...................................................................................................................104

8.13 AT^SPLM Read the PLMN List ..................................................................................................................105

8.14 AT^CPOL Preferred Operator List..............................................................................................................105

8.15 AT^SPLR Read Entry from the Preferred Operators List ...........................................................................106

8.16 AT^SPLW Write an Entry to the Preferred Operators List..........................................................................106

Chapter 9. Supplementary Service Commands...................................................................................................107

9.1 AT+CACM Accumulated Call Meter (ACM) Reset or Query ........................................................................107

9.2 AT^SACM Advice of Charge and Query of ACM and ACMmax...................................................................107

9.3 AT+CAMM Accumulated Call Meter Maximum (ACMmax) Set or Query.....................................................108

9.4 AT+CAOC Advice of Charge Information.....................................................................................................108

9.5 AT+CCUG Closed User Group ....................................................................................................................109

9.6 AT+CCFC Call Forwarding Number and Conditions Control .......................................................................110

9.7 AT+CCWA Call Waiting ...............................................................................................................................112

9.8 AT+CHLD Call Hold and Multiparty..............................................................................................................114

9.9 AT+CLIP Calling Line Identification Presentation.........................................................................................116

9.10 AT+CLIR Calling Line Identification Restriction..........................................................................................117

9.11 AT+COLP Connected Line Identification Presentation...............................................................................117

9.12 AT+CPUC Price Per Unit and Currency Table...........................................................................................118

9.13 AT+CSSN Supplementary Service Notifications ........................................................................................119

9.14 AT+CUSD Supplementary Service Notifications ........................................................................................120

Chapter 10. Internet Service Commands .............................................................................................................121

10.1 AT^SICS Internet Connection Setup Profile...............................................................................................122

10.1.1 Example: Default Values of a CSD Connection Profile ............................................................................124

10.1.2 Example: GPRS Connection Profile.........................................................................................................124

10.2 AT^SISS Internet Service Setup Profile .....................................................................................................125

10.2.1 Example: Configuring Socket Listener ...................................................................................................130

10.2.2 Example: Configuring Socket Client for Calling a Socket Listener on Another Host ..............................131

10.2.3 Example: Configuring and Using FTP Download ...................................................................................131

10.2.4 Example: Configuring and Using FTP Upload........................................................................................132

10.2.5 Example: Sending Email over GPRS .......................................................................................................132

10.3 AT^SISO Internet Service Open.................................................................................................................134

10.3.1 Example: Accepting/Rejecting Socket Connection Request from Remote Client ..................................135

10.4 AT^SISC Internet Service Close ................................................................................................................137

10.4.1 Effect of Parameter <closeMode>............................................................................................................137

10.5 AT^SISR Internet Service Read Data ........................................................................................................138

10.5.1 Example: Socket Host Reads Small Amounts of UDP Data Packets.....................................................139

10.6 AT^SISW Internet Service Write Data........................................................................................................140

10.7 Information Elements Related to Internet Service URCs .............................................................................141

10.7.1 URC Information Elements Related to the Service Application................................................................141

10.7.2 URC Information Elements Related to FTP Service...............................................................................142

10.7.3 URC Information Elements Related to HTTP Service..............................................................................142

10.7.4 URC Information Elements Related to POP3 Service..............................................................................142

10.7.5 URC Information Elements Related to SMTP Service .............................................................................142

Chapter 11. GPRS Commands ................................................................................................................................143

11.1 AT+CGACT PDP Context Activate or Deactivate.......................................................................................143

11.2 AT+CGANS Manual Response to a Network Request for PDP Context Activation ...................................144

11.3 AT+CGATT GPRS Attach or Detach..........................................................................................................145

11.4 AT+CGAUTO Automatic Response to a Network Request for PDP Context Activation.............................146

11.5 AT+CGDATA Enter Data State ..................................................................................................................147

11.5.1 Automatic Deactivation of PDP Context During Dial-up PPP...................................................................147

11.6 AT+CGDCONT Define PDP Context .........................................................................................................148

11.7 AT+CGEQMIN 3G Quality of Service Profile (Minimum Acceptable) .........................................................149

11.8 AT+CGEQREQ 3G Quality of Service Profile (Requested)........................................................................152

11.9 AT+CGPADDR Show PDP Adress ............................................................................................................154

11.10 AT+CGQMIN Quality of Service Profile (Minimum Acceptable) ...............................................................155

11.11 AT+CGQREQ Quality of Service Profile (Requested)..............................................................................157

11.12 AT+CGREG GPRS Network Registration Status .....................................................................................159

11.13 AT+CGSMS Select Service for MO SMS Messages................................................................................160

11.14 AT^SGACT Query All PDP Context Activations .......................................................................................161

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 5

Table of Contents

11.15 AT^SGAUTH Set Type of Authentication for PPP Connection.................................................................162

11.16 AT^SGCONF Configuration of GPRS-Related Parameters .....................................................................162

11.17 ATA Manual Response to a Network Request for PDP Context Activation..............................................163

11.18 ATD*99# Request GPRS Service ............................................................................................................163

11.19 ATD*98# Request GPRS IP Service........................................................................................................164

11.20 ATH Manual Rejection of a Network Request for PDP Context Activation...............................................164

11.21 ATS0 Automatic Response to a Network Request for PDP Context Activation........................................165

11.22 Using GPRS AT Commands (Examples) ...................................................................................................166

11.23 Using the GPRS Dial Command ATD (Example).......................................................................................167

Chapter 12. FAX Commands ...................................................................................................................................168

12.1 FAX Parameters...........................................................................................................................................168

12.2 AT+FCLASS Fax: Select, Read or Test Service Class ..............................................................................168

12.3 AT+FRH Receive Data Using HDLC Framing............................................................................................169

12.4 AT+FRM Receive Data ..............................................................................................................................169

12.5 AT+FRS Receive Silence...........................................................................................................................169

12.6 AT+FTH Transmit Data Using HDLC Framing ...........................................................................................169

12.7

AT+FTM Transmit Data..............................................................................................................................170

12.8

AT+FTS Stop Transmission and Wait ........................................................................................................170

Chapter 13. Short Message Service (SMS) Commands........................................................................................171

13.1 SMS Parameters..........................................................................................................................................171

13.2 AT+CMGC Send an SMS Command .........................................................................................................174

13.3 AT+CMGD Delete SMS Message ..............................................................................................................174

13.4 AT+CMGF Select SMS Message Format ..................................................................................................174

13.5 AT+CMGL List SMS Messages from Preferred Store ................................................................................175

13.6 AT+CMGR Read SMS Messages ..............................................................................................................176

13.7 AT+CMGS Send SMS Message ................................................................................................................177

13.8 AT+CMGW Write Short Messages to Memory...........................................................................................178

13.9 AT+CMSS Send Short Messages from Storage ........................................................................................179

13.10 AT+CNMA New SMS Message Acknowledge to ME/TE Phase 2+ .........................................................179

13.11 AT+CNMI New Short Message Indication................................................................................................180

13.12 AT+CPMS Preferred SMS Message Storage ..........................................................................................182

13.13 AT+CSCA SMS Service Center Address .................................................................................................183

13.14 AT+CSCB Select Cell Broadcast Message Indication..............................................................................183

13.15 AT+CSDH Show SMS Text Mode Parameters ........................................................................................184

13.16 AT+CSMP Set SMS Text Mode Parameters............................................................................................184

13.17 AT+CSMS Select Message Service.........................................................................................................185

13.18 AT^SCML List Concatenated Short Messages from Preferred Store.......................................................186

13.19 AT^SCMR Read Concatenated Short Messages.....................................................................................187

13.20 AT^SCMS Send Concatenated Short Messages .....................................................................................188

13.21 AT^SCMW Write Concatenated Short Messages to Memory ..................................................................188

13.22 AT^SLMS List SMS Memory Storage ......................................................................................................189

13.23 AT^SMGL List Short Messages from Preferred Store without Setting Status to REC READ...................189

13.24 AT^SMGO Set or Query SMS Overflow Pesentation Mode or Query SMS Overflow ..............................190

13.25 AT^SMGR Read Short Message without Setting Status to REC READ...................................................190

13.26

AT^SSCONF SMS Command Configuration ...........................................................................................191

13.27 AT^SSDA Set SMS Display Availability ...................................................................................................191

13.28 AT^SSMSS Set Short Message Storage Sequence ................................................................................192

Chapter 14. SIM-Related Commands......................................................................................................................193

14.1 AT+CRSM Restricted SIM Access .............................................................................................................193

14.2 AT^SXSM Extended SIM Access...............................................................................................................195

14.3 AT^SCKS Query SIM and Chip Card Holder Status ..................................................................................196

14.4 AT^SSET Indicate SIM Data Ready...........................................................................................................197

14.5 AT^SCID Display SIM Card Identification Number.....................................................................................197

14.6 AT+CXXCID Display Card ID.....................................................................................................................197

Chapter 15. SIM Application Toolkit (SAT) Commands ........................................................................................198

15.1 AT^SSTA SAT Interface Activation ............................................................................................................198

15.2 ^SSTN SAT Notification .............................................................................................................................199

15.3 AT^SSTGI SAT Get Information.................................................................................................................200

15.4 AT^SSTR SAT Response ..............................................................................................................................200

Chapter 16. Phonebook Commands.......................................................................................................................201

16.1 Sort Order for Phonebooks ..........................................................................................................................201

16.2 AT+CNUM Read Own Numbers ................................................................................................................202

16.3 AT+CPBR Read from Phonebook..............................................................................................................202

16.4 AT+CPBS Select Phonebook Memory Storage .........................................................................................204

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 6

Table of Contents

16.5 AT+CPBW Write into Phonebook...............................................................................................................205

16.6 AT^SDLD Delete the ‘Last Number Redial Memory...................................................................................207

16.7 AT^SPBC Find First Matching Entry in Sorted Phonebook ........................................................................207

16.8 AT^SPBD Purge Phonebook Memory Storage ..........................................................................................208

16.9 AT^SPBG Display Phonebook Entries in Alphabetical Order.....................................................................209

16.10 AT^SPBS Step Through the Selected Phonebook Alphabetically............................................................211

Chapter 17. Audio Commands ................................................................................................................................213

17.1 Audio Programming Model...........................................................................................................................213

17.2 ATL Set Monitor Speaker Loudness ..........................................................................................................213

17.3 ATM Set Monitor Speaker Mode ................................................................................................................213

17.4 AT+CLVL Loudspeaker Volume Level .......................................................................................................214

17.5 AT+CMUT Mute Control.............................................................................................................................214

17.6 AT+VTD Tone Duration..............................................................................................................................215

17.7 AT+VTS DTMF and Tone Generation........................................................................................................215

17.8 AT^SAIC Audio Interface Configuration .....................................................................................................216

17.9 AT^SNFA Set or Query of Microphone Attenuation ...................................................................................217

17.10 AT^SNFD Set Audio Parameters to Manufacturer Default Values ...........................................................218

17.11 AT^SNFI Set Microphone Path Parameters.............................................................................................218

17.12 AT^SNFM Set Microphone Audio Path ....................................................................................................219

17.13 AT^SNFO Set Audio Output (= Loudspeaker Path) Parameter................................................................220

17.14 AT^SNFPT Set Progress Tones...............................................................................................................221

17.15 AT^SNFS Select Audio Hardware Set .........................................................................................................221

17.16 AT^SNFTTY Signal TTY/CTM Audio Mode Capability.............................................................................222

17.17 AT^SNFV Set Loudspeaker Volume ........................................................................................................223

17.18 AT^SNFW Write Audio Setting in Non-Volatile Store ...............................................................................223

17.19 AT^SRTC Ring Tone Configuration .........................................................................................................224

Chapter 18. Hardware-Related Commands............................................................................................................225

18.1 AT+CCLK Real Time Clock........................................................................................................................225

18.2

AT+CALA Set Alarm Time .........................................................................................................................226

18.3 Intentionally Omitted ....................................................................................................................................228

18.4 Intentionally Omitted ....................................................................................................................................228

18.5 AT^SCTM Set Critical Operating Temperature Presentation Mode or Query Temperature .......................228

18.6 AT^SSYNC Configure SYNC Pin ...............................................................................................................230

18.6.1 ME Status Indicated by Status LED Patterns...........................................................................................230

Chapter 19. Miscellaneous Commands..................................................................................................................232

19.1 A/ Repeat Previous Command Line ...........................................................................................................232

19.2 ATS3 Set Command Line Termination Character ......................................................................................232

19.3 ATS4 Set Response Formatting Character ................................................................................................232

19.4 ATS5 Write Command Line Editing Character ...........................................................................................233

Chapter 20. Summary Tables..................................................................................................................................234

20.1 Restricted Access to SIM Data after SIM PIN Authentication.......................................................................234

20.2 Star-Hash (*#) Network Commands.............................................................................................................235

20.3 AT Commands and SIM PIN Dependency...................................................................................................237

20.4 Availability of AT Commands Depending on Operating Mode of ME ...........................................................241

20.5 AT Command Settings Storable with AT&W ................................................................................................245

20.6 Factory Defaults Restorable with AT&F .......................................................................................................246

20.7 Summary of Unsolicited Result Codes (URC)..............................................................................................248

20.8 AT Commands Not Usable for USB .............................................................................................................249

20.9 Alphabetical List of AT Commands ..............................................................................................................250

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 7

Table of Contents

Tables

Table 1.4: Types of AT commands and responses ................................................................................. 10

Table 1.5: Examples for character definitions depending on alphabet .................................................... 11

Table 2.1: Current configuration on ASC0 / MUX channel 1 (example) .................................................. 20

Table 2.3: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes.............................................. 24

Table 2.4: General “CME ERROR” Codes (GSM 07.07) .........................................................................26

Table 2.5: GPRS related “CME ERROR” Codes (GSM 07.07) ............................................................... 27

Table 2.6: SMS related “CMS ERROR” Codes (GSM 07.05) ................................................................. 27

Table 2.7: SMS related “CMS ERROR” Codes (GSM 07.05) ................................................................. 27

Table 2.8: SMS related “CMS ERROR” Codes (GSM 07.05) ................................................................. 27

Table 4.1: Availability of AT Commands on Virtual Channels ..................................................................57

Table 4.2: Summary of AT commands with Different Behavior in Multiplex Mode .................................. 57

Table 10.1 Applicability of AT^SICS <conParmTag> values.................................................................. 122

Table 18.2: Modes of the LED and indicated ME functions..................................................................... 230

Table 18.3: Special characters for ASCII coding.................................................................................... 234

Table 18.4: Structure of Transfer and Response Messages on the I²C bus............................................ 235

Table 20.1: Star-Hash (*#) Command Overview .................................................................................... 240

Table 20.2: Abbreviations of Codes and Parameters used in Table 20.1 .............................................. 241

Table 20.3: Star-Hash Command Response Parameters ...................................................................... 241

Table 20.4: Star-Hash Commands for Supplementary Services ............................................................ 241

Table 20.5: Available AT Commands and Dependency on SIM PIN....................................................... 242

Table 20.6: Availability of AT Commands Depending on Operating Mode of ME.................................. 246

Table 20.7: Settings Stored to User Profile on ASC0 / MUX Channel 1.................................................. 250

Table 20.8: Factory Default Settings Restorable with AT&F ................................................................... 251

Table 20.9: Summary of Unsolicited Result Codes (URC) ..................................................................... 253

Table 20.10: Alphabetical List of AT Commands..................................................................................... 255

Figures

Figure 1.1: Main character table of GSM 03.38 alphabet ....................................................................... 12

Figure 1.2: Extension character table of GSM 03.38 alphabet ................................................................ 13

Figure 17.1: Audio programming model................................................................................................... 213

Figure 18.1: Formula for calculating delay time..................................................................................... 233

Figure 18.2: Delay time on 12C after Write............................................................................................. 233

Figure 18.3: Delay time on 12C after Read.............................................................................................. 233

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 8

Chapter 1 – Introduction

Chapter 1. Introduction

1.1 Scope of the Document

This document presents the AT Command set for the Multi-Tech Systems, Inc. wireless Edge devices.

1.2 Related Documents

1. ITU-T Recommendation V.24: List of definitions for interchange circuits between data terminal equipment

(DTE) and data circuit-terminating equipment (DCE)

2. ITU-T Recommendation V.250: Serial asynchronous automatic dialing and control

3. 3GPP TS 100 918/EN 300 918 (GSM 02.04): General on supplementary services

4. 3GPP TS 100 907 (GSM 02.30): Man-Machine Interface (MMI) of the Mobile Station (MS)

5. 3GPP TS 23.038 (GSM 03.38): Alphabets and language specific information

6. 3GPP TS 27.005 (GSM 07.05): Use of Data Terminal Equipment - Data Circuit terminating Equipment (DTE

- DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS)

7. 3GPP TS 27.007 (GSM 07.07): AT command set for User Equipment (UE)

8. 3GPP TS 27.060 (GSM 07.60): Mobile Station (MS) supporting Packet Switched Services

9. 3GPP TS 51.011 (GSM 11.11): Specification of the Subscriber Identity Module - Mobile Equipment (SIM -

ME) interface

10. 3GPP TS 11.14 (GSM 11.14): Specification of the SIM Application Toolkit for the Subscriber Identity Module

- Mobile Equipment (SIM - ME) interface

11. 3GPP TS 22.101 (GSM 22.101): Service principles

12. Common PCN Handset Specification (CPHS) v4.2

1.3 Document Conventions

Throughout the document, the GSM engines are referred to as:

ME (Mobile Equipment)

MS

TA

(Mobile Station)

(Terminal Adapter)

DCE (Data Communication Equipment)

Facsimile DCE (FAX modem, FAX board)

To control your GSM engine you can simply send AT Commands via its serial interface. The controlling device at the other end of the serial line is referred to as:

TE (Terminal Equipment)

DTE (Data Terminal Equipment) or ‘the application’ (probably running on an embedded system).

All abbreviations and acronyms used throughout this document are based on the GSM specifications. For definitions please refer to TR 100 350 V7.0.0 (1999-08), (GSM 01.04, version 7.0.0 release 1998).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 9

Chapter 1 – Introduction

1.4 AT Command Syntax

The “AT” or “at” prefix must be set at the beginning of each command line. To terminate a command line enter <CR>.

Commands are usually followed by a response that includes “<CR><LF><response><CR><LF>”. Throughout this document, only the responses are presented, <CR><LF> are omitted intentionally.

Table 1.4: Types of AT commands and responses.

AT Cmmand Type Syntax

Test command AT+CXXX=?

Read command

Write command

Exec(ution) command

AT+CXXX? set with the corresponding Write command or by internal processes.

This command returns the currently set value of the parameter(s).

AT+CXXX=<...> This command sets user-definable parameter values.

AT+CXXX

Function

The mobile equipment returns the list of parameters and value ranges

The execution command reads non-variable parameters determined by internal processes in the GSM engine.

1.4.1 Using Parameters

• Optional parameters are enclosed in square brackets. If optional parameters are omitted, the current settings are used until you change them.

• Optional parameters or subparameters can be omitted unless they are followed by other parameters. If you want to omit a parameter in the middle of a string it must be replaced by a comma. See also example 1.

• A parameter value enclosed in square brackets represents the value that will be used if an optional parameter is omitted. See also example 2.

• When the parameter is a character string; e.g., <text> or <number>, the string must be enclosed in quotation marks (e.g., “Charlie Brown” or “+49030xxxx”). Symbols in quotation marks will be recognized as strings.

• All spaces will be ignored when using strings without quotaton marks.

• It is possible to omit the leading zeros of strings which represent numbers.

• If an optional parameter of a V.250 command is omitted, its value is assumed to be 0.

Example 1: Omitting parameters in the middle of a string

AT+CCUG?

+CCUG: 1,10,1

OK

AT+CCUG=,9

OK

AT+CCUG?

+CCUG: 1,9,1

OK

Query current setting

Set only the middle parameter

Query new setting

Example 2: Using default parameter values for optional parameters

AT+CFUN=7,0

OK

AT+CFUN?

+CFUN: 7

OK

AT+CFUN=

OK

+CFUN: 1

OK

Activate CYCLIC SLEEP mode, don’t reset ME

Query ME mode

Set ME back to normal (default parameters: 1,0)

1.4.2 Combining AT Commands on the Same Command Line

You may enter several commands on the same line. This eliminates the typing of “AT” or “at” before each command. Instead, it is needed only once - at the beginning of the command line. Use a semicolon as command delimiter.

The table below lists the AT commands you cannot enter together with other commands on the same line.

Otherwise, the responses may not be in the expected order.

AT Command Type

V.250 commands

GSM 7.07 commands

GSM 7.05 commands

Commands starting with AT&

AT+IPR

Comment with FAX commands (Prefix AT+F) with AT commands, Prefix AT^S)

(SMS) To be used as standalone commands

To be used as standalone commands

To be used as standalone commands

Note: When concatenating AT commands please keep in mind that the sequence of processing may be different from the sequential order of command input. Therefore, if the consecutive order of the issued commands and associated responses is your concern, avoid concatenating commands on the same line.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 10

Chapter 1 – Introduction

1.5 Supported Character Sets

The ME supports two character sets: GSM 03.38 (7 bit, also referred to as GSM alphabet or SMS alphabet) and

UCS2 (16 bit, refer to ISO/IEC 10646). See AT+CSCS for information about selecting the character set. Character tables can be found below.

Explanation of terms

International Reference Alphabet (IRA)

IRA means that one byte is displayed as two characters in hexadecimal format. For example, the byte 0x36

(decimal 54) is displayed as “36” (two characters). IRA is used here for input 8-bit or 16-bit data via terminal devices using text mode. This means only characters ‘A’..F’,’a’..’f’ and ‘0’..’9’ are valid.

Escape sequences

The escape sequence used within a text coded in the GSM default alphabet (0x1B) must be correctly interpreted by the TE, both for character input and output. To the module, an escape sequence appears like any other byte received or sent.

Terminal Adapter (TA)

TA is used equivalent to Mobile Equipment (ME) which stands for the GSM module described here. It uses

GSM default alphabet as its character set.

Terminal Equipment (TE)

TE is the device connected to the TA via serial interface. In most cases TE is an ANSI/ASCII terminal that does not fully support the GSM default alphabet, for example MS Hyperterminal.

TE Character Set

The character set currently used by Terminal Equipment is selected with AT+CSCS.

Data Coding Scheme (dcs)

DCS is part of a short message and is saved on the SIM. When writing a short message to the SIM in text mode, the dcs stored with AT+CSMP is used and determines the coded character set.

The behavior when encountering characters, that are not valid characters of the supported alphabets, is undefined.

Due to the constraints described below it is recommended to prefer the USC2 alphabet in any external application.

If the GSM alphabet is selected all characters sent over the serial line (between TE and TA) are in the range from 0 to

127 (7 Bit range). CAUTION: ASCII alphabet (TE) is not GSM alphabet (TA/ME) !

Several problems resulting from the use of GSM alphabet with ASCII terminal equipment:

• “@” character with GSM alphabet value 0 is not printable by an ASCII terminal program (e.g., Microsoft©

Hyperterminal®).

• “@” character with GSM alphabet value 0 will terminate any C string! This is because the 0 is defined as C string end tag. Therefore, the GSM Null character may cause problems on application level when using a

‘C’- function as “strlen()”. This can be avoided if it is represented by an escape sequence as shown in the table below.

By the way, this may be the reason why even network providers often replace “@”with “@=*” in their SIM application.

• Other characters of the GSM alphabet are misinterpreted by an ASCII terminal program. For example, GSM

“ö” (as in “Börse”) is assumed to be “|” in ASCII, thus resulting in “B|rse”. This is because both alphabets mean different characters with values hex. 7C or 00 and so on.

• In addition, decimal 17 and 19 which are used as XON/XOFF control characters when software flow control is activated, are interpreted as normal characters in the GSM alphabet.

When you write characters differently coded in ASCII and GSM (e.g., Ä, Ö, Ü), you need to enter escape sequences. Such a character is translated into the corresponding GSM character value and, when output later, the GSM character value can be presented. Any ASCII terminal then will show wrong responses.

Table 1.5: Examples for character definitions depending on alphabet

GSM 03.38 character

Ö

ò

@

GSM character hex. value

5C

22

08

00

Corresponding

ASCII character

\

BSP

NULL

ASCII Esc sequence

\5C

\22

\08

\00

Hex Esc sequence

5C 35 43

5C 32 32

5C 30 38

5C 30 30

CAUTION: Often, the editors of terminal programs do not recognize escape sequences. In this case, an escape sequence will be handled as normal characters. The most common workaround to this problem is to write a script which includes a decimal code instead of an escape sequence. This way you can write, for example, short messages which may contain differently coded characters.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 11

Chapter 1 – Introduction

1.5.1 GSM Alphabet Tables and UCS2 Character Values

This section provides tables for the GSM 03.38 alphabet supported by the ME. Below any GSM character find the corresponding two byte character value of the UCS2 alphabet.

Figure 1.1: Main character table of GSM 03.38 alphabet

1. This code is an escape to the following extension of the 7 bit default alphabet table.

2. This code is not a printable character and therefore not defined for the UCS2 alphabet. It shall be treated as the accompanying control character.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 12

Chapter 1 – Introduction

Figure 1.2: Extension character table of GSM 03.38 alphabet

1. This code value is reserved for the extension to another extension table. On receipt of this code, a receiving entity shall display a space until another extension table is defined.

2. This code represents the EURO currency symbol. The code value is the one used for the character ‘e’. Therefore a receiving entity which is incapable of displaying the EURO currency symbol will display the character ‘e’ instead.

3. This code is defined as a Page Break character and may be used for example in compressed CBS messages.

Any mobile which does not understand the 7 bit default alphabet table extension mechanism will treat this character as Line Feed.

In the event that an MS receives a code where a symbol is not represented in Figure 1.2, Extension character table of

GSM 03.38 alphabet the MS shall display the character shown in the main default 7 bit alphabet table (see Figure

1.1, Main character table of GSM 03.38 alphabet).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 13

Chapter 1 – Introduction

1.5.2 UCS2 and GSM Data Coding and Conversion for SMS Text Mode

This section provides basic information on how to handle input and output character conversion for SMS text mode and Remote-SAT if the internal (TA) and external (TE) character representation differ; e.g., if the Data Coding

Scheme and the TE character use different coding.

1.5.2.1 Implementing Output of SIM Data to Terminal (Direction TA to TE)

Used Character

Set

DCS = 7 bit

GSM

DCS = 8 bit

Data

GSM (1:1) 8 bit to IRA (1:2)

4

GSM to IRA (1:4)

Case 5

8 bit to IRA (1:4)

DCS = 16 bit

UCS2

Case 3

UCS2 to IRA (2:4)

Case 6

UCS2 to IRA (2:4)

Note: The ratio of SIM bytes to output bytes is given in parentheses.

Case 1

Every GSM character is sent to TE as it is (8-bit value with highest bit set to zero).

Example: 47’H, 53’H, 4D’H 47’H, 53’H, 4D’H, displayed as “GSM”.

Case 2

Every data byte will is sent to TE as 2 IRA characters each representing a halfbyte.

Example: B8’H (184 decimal) 42’H, 38’H, displayed as “B8”.

Case 3

Every 16-bit UCS2 value is sent to TE as 4 IRA characters.

Example: C4xA7’H (50343 decimal) 43’H, 34’H, 41’H, 37’H, displayed as “C4A7”.

Problem: An odd number of bytes leads to an error because there are always two bytes needed for each USC2 character.

Case 4

Every GSM character is sent to TE as 4 IRA characters to show UCS2 in text mode.

Example: 41’H (“A”) 30’H, 30’H, 34’H, 31’H, displayed as “0041”.

Case 5

Every data byte is sent to TE as IRA representation of UCS2 (similar to case 4).

Example: B2’H 30’H, 30’H, 42’H, 32’H, displayed as “00B2”.

Case 6

Every 16-bit value is sent to TE as IRA representation of it. It is assumed that number of bytes is even.

Example: C3x46’H 43’H, 33’H, 34’H, 36’H, displayed as “C346”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 14

Chapter 1 – Introduction

1.5.2.2 Implementing Input of Terminal Data to SIM (Direction TE to TA)

Used Character DCS = 7 bit DCS = 8 bit

Set GSM Data

GSM Case Case 2

GSM (1:1) IRA to 8 bit (2:1)

4

GSM to IRA (1:4)

Case 5

8 bit to IRA (1:4)

DCS = 16 bit

UCS2

Case 3

IRA to 16 bit (4:2)

Case 6

UCS2 to IRA (2:4)

Note: The ratio between the number of input characters and bytes stored on the SIM is given in parentheses.

Case 1

Every character is sent from TE to TA as GSM character (or ASCII with Hyperterminal).

Character value must be in range from 0 to 127 because of 7-bit GSM alphabet.

To reach maximum SMS text length of 160 characters in 140 bytes space characters will be compressed on SIM.

This must be set using the parameter <dcs> of AT+CSMP (add 64).

Example: “ABCDEFGH” typed is sent and stored uncompressed as 4142434445464748’H (stored compressed as 41E19058341E91’H).

Case 2

Every data byte is sent to TA as 2 IRA characters.

Maximum text length is 280 IRA characters which will be converted into 140 bytes SMS binary user data.

Example: “C8” typed is sent as 43’H, 38’H stored as C8’H.

Case 3

Every 16-bit value is sent to TA as 4 IRA characters.

Maximum text length is 280 IRA characters which will be converted into 70 UCS2 characters (16-bit each).

Number of IRA characters must be a multiple of four because always 4 half bytes are needed for a 16-bit value.

Example: “D2C8” typed is sent as 44’H, 32’H, 43’H, 38’H stored as D2C8’H.

Case 4

Every GSM character is sent to TA as 4 IRA characters representing one UCS2 character.

Example: To store text “ABC” using UCS2 character set you have to type “004100420043”.

This is sent as 30’H,30’H,34’H,31’H, 30’H,30’H,34’H,32’H, 30’H,30’H,34’H,33’H detected as IRA representation of 3 UCS2 characters, converted to GSM character set and stored as 41’H, 42’H, 43’H.

Maximum input is 640 IRA characters repesenting 160 UCS2 characters when compression is active. These are converted to 160 GSM 7-bit characters.

Without compression only 140 GSM characters can be stored which are put in as 560 IRA characters.

Values of UCS2 characters must be smaller than 80’H (128 decimal) to be valid GSM characters.

Number of IRA characters must be a multiple of four. Problems:

• “41” ¨ Error, there are four IRA characters (two bytes) needed

• “0000” Error, not an UCS2 character

• “4142” Error, value of UCS2 character > 7F’H

• “008B” Error, value of UCS2 character > 7F’H

This affects the maximum input length of a string)

Case 5

Every UCS2 character is sent as 4 IRA characters and is converted into two 8-bit values. This means that the first two characters have to be ‘00’.

Example: UCS2 character 009F’H typed as “009F” is sent as 30’H,30’H,39’H,46’H ¨ converted into 8-bit value

9F’H.

Maximum number of UCS2 characters is 140 which are represented by 560 IRA characters. Number of IRA characters must be a multiple of four.

Case 6

Every UCS2 character is sent as 4 IRA characters each and is converted into a 16-bit value again.

Example: UCS2 character 9F3A’H typed as “9F3A” is sent as 39’H,46’H,33’H,41’H converted into 9F3A’H.

Maximum number of UCS2 characters is 70 which are represented by 280 IRA characters. Number of IRA characters must be a multiple of four.

Invalid UCS2 values must be prevented.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 15

Chapter 1 – Introduction

1.6 Serial Interface Flow Control

Flow control is essential to prevent loss of data or avoid errors when, in a data or fax call, the sending device is transferring data faster than the receiving side is ready to accept. When the receiving buffer reaches its capacity, the receiving device should be capable to cause the sending device to pause until it catches up.

There are basically two approaches to regulate data flow: Software flow control and hardware flow control. The High

Watermark of the input/output buffer should be set to approximately 60% of the total buffer size. The Low Watermark is recommended to be about 30%. The data flow should be stopped when the capacity rises close to the High

Watermark and resumed when it drops below the Low Watermark. The time required to cause stop and go results in a hysteresis between the High and Low Watermarks.

During Multiplex mode (AT+CMUX) it is recommended to use hardware flow control.

1.6.1 Software Flow Control (XON/OFF Handshake)

Software flow control sends different characters to stop (XOFF, decimal 19) and resume (XON, decimal 17) data flow.

The only advantage of software flow control is that three wires would be sufficient on the serial interface.

1.6.2 Hardware Flow Control (RTS/CTS Handshake)

Hardware flow control sets or resets the RTS/CTS wires. This approach is faster and more reliable, and therefore, the better choice. When the High Watermark is reached, CTS is set inactive until the transfer from the buffer has completed. When the Low Watermark is passed, CTS goes active again.

To achieve smooth data flow, ensure that the RTS/CTS lines are present on your application platform. The application should include options to enable RTS/CTS handshake with the GSM engine. This needs to be done with the AT command AT\Q3 - it is not sufficient to set RTS/CTS handshake in the used Terminal program only.

The default setting of the GSM engine is AT\Q0 (no flow control) which must be altered to AT\Q3 (RTS/CTS hardware handshake on). The setting is stored volatile and must be restored each time after the GSM engine was switched off.

AT\Q has no read command. To verify its current setting, simply check the settings of the active profile with AT&V.

Often, fax programs run an intialization procedure when started up. The intialization commonly includes enabling

RTS/CTS hardware handshake, eliminating the need to set AT\Q3 once again. However, before setting up a CSD call, you are advised to check that RTS/CTS handshake is set.

RTS/CTS hardware handshake must also be set if you want to take advantage of the CYCLIC SLEEP modes.

For further details refer to AT+CFUN.

1.7 Unsolicited Result Code Presentation

URC stands for Unsolicited Result Code and is a report message issued by the ME without being requested by the

TE; e.g., a URC is issued automatically when a certain event occurs. Hence, a URC is not issued as part of the response related to an executed AT command.

Typical events leading to URCs are incoming calls (“RING”), waiting calls, received short messages, changes in temperature, network registration etc.

A list of all URCs can be found in Section 20.7, Summary of Unsolicited Result Codes (URC).

To announce a pending URC transmission the ME will do the following:

• The ME activates its RING line (logic “1”) for one second; i.e., the line changes to physical “Low” level. This allows the TE to stay in power saving mode until an ME-related event requests service. If several URCs occur conincidentally or in quick succession, each URC triggers the RING line independently, although the line will not be activated between each URC. As a result, the RING line may stay low for more than one second.

If an incoming call is answered within less than one second (with ATA or if autoanswering is set to ATSO=1, then the RING line will be deactivated earlier.

The “^SHUTDOWN” URC will not activate the RING line.

• If the AT command interface is busy a “BREAK” will be sent immediately but the URC will not be issued until the line is free. This may happen if the URC is pending in the following cases:

∗ During the processing of an AT command (i.e., the time after the TE echoes back the first character “A” of an AT command just sent by itself until the ME responds with “OK” or “ERROR”).

∗ During a data call.

Please note that AT command settings may be necessary to enable in-band signaling; e.g., refer to

AT+CMER or AT+CNMI.

It is strongly recommended to use the multiplex mode to map logical communication channels onto the serial line of the Multi-Tech wireless modem, for details refer to [5] and AT command AT+CMUX. Doing so it is possible to use one channel to still process URCs while having a data call active on another.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 16

Chapter 1 – Introduction

For most of these messages, the ME needs to be configured whether or not to send a URC. Depending on the AT command, the URC presentation mode can be saved to the user defined profile (see AT&W), or needs to be activated every time you reboot the ME. Several URCs are not user definable, such as “^SYSSTART”, “^SYSSTART

<text>”, “^SHUTDOWN”.

If autobauding is enabled (as factory default mode or set with AT+IPR=0), URCs generated after restart will be output with 57600 bps until the ME has detected the current bit rate. The URCs “^SYSSTART”, “^SYSSTART

<text>”, however, are not presented at all. For details please refer to Section 4.9.1, Autobauding. To avoid problems we recommend to configure a fixed bit rate rather than using autobauding.

1.7.1 Communication between Customer Application and Multi-Tech Wireless

Modem

Leaving hardware flow control unconsidered the Customer Application (TE) is coupled with the Multi-Tech wireless modem (ME) via a receive and a transmit line.

Since both lines are driven by independent devices, collisions may (and will) happen; i.e., while the TE issues an AT command, the Multi-Tech wireless modem starts sending an URC. This will probably lead to the TE’s misinterpretation of the URC being part of the AT command’s response.

To avoid this conflict the following measures must be taken:

• If an AT command is finished (with “OK” or “ERROR”) the TE shall always wait at least 100 milliseconds before sending the next one.

This gives the Multi-Tech wireless modem the opportunity to transmit pending URCs and get necessary service.

Note that some AT commands may require more delay after “OK” or “ERROR” response, refer to the following command specifications for details.

• The TE shall communicate with the Multi-Tech wireless modem using activated echo (ATE1); i.e., the Multi-Tech wireless modem echoes characters received from the TE.

Hence, when the TE receives the echo of the first character “A” of the AT command just sent by itself it has control both over the receive and the transmit paths.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 17

Chapter 1 – Introduction

1.8 Common PCN Handset Specification (CPHS)

The ME provides features to implement a device following the prerequisites of the Common PCN Handset

Specification (CPHS) Phase 2.

CPHS Feature Description/Remarks AT command

Alternate Line Service

Voice Message Waiting

Indication

Using two phone numbers with one SIM card.

Indicate the receipt of a short message coded as Voice

Message Waiting Indicator as defined by the CPHS Phase 2 standard.

Read specific Elementary Files (6F14h, 6F18h) from SIM.

AT^SALS

AT^SIND,

AT+CMER, indicators

“vmwait1” and “vmwait2”

AT+CRSM Operator (Service provider) name from SIM

Network and Service Provider

Lock

Call Forwarding

Lock/Unlock an ME to specific HPLMN and service provider. AT+CLCK, (AT+CPIN)

AT+CCFC, AT+CRSM

Customer Service Profile

(CSP)

Information numbers

Get and set diverted call status. Access specific Elementary

File (6F13h) from SIM.

Setting services and their menu entries depending on customer profiles.

Hierarchically structured service numbers phonebook on

SIM according to CPHS 4.2 (mandatory).

AT+CRSM

AT+CRSM

1.9 Errors and Messages

The command result codes “+CME ERROR: <err>” and “+CMS ERROR: <err>” indicate errors related to mobile equipment or network functionality.

The format of <err> can be either numeric or verbose and is selectable via AT+CMEE.

A result error code terminates the execution of the command and prevents the execution of all remaining commands that may follow on the same command line. If so, neither “ERROR” nor “OK” result codes are returned for these commands. A 30 seconds timeout will deliver “ERROR” when the input of a command is not complete.

Using the wrong command syntax may result in errors: For example, using the execute command syntax although the command has no execute format, causes “ERROR” to be returned. Likewise, using the write command syntax although the command has no write format causes “+CME ERROR: <err>” to be returned.

See also:

• Section 2.12.1, CME/CMS Error Code Overview

• Section 2.5.1, Verbose and numeric result codes

• Section 3.4, AT+CEER

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 18

Chapter 2 – Configuration Commands

Chapter 2. Configuration

Commands

The AT commands described in this chapter allow the external application to determine the modem’s behavior under various conditions.

2.1 AT&F Set All Current Parameters to

Manufacturer Defaults

Description: AT&F sets all current parameters to the manufacturer defined profile. All defined GPRS contexts which are not activated or not online will be “undefined” (see AT+CGDCONT).

Exec Command Syntax: AT&F[value]

Response: OK

Parameter Description:

<value>

0

Notes:

Sets all TA parameters to manufacturer defaults.

• List of parameters reset to manufacturer default can be found in Section 20.6, Factory Default Settings

Restorable with AT&F.

• In addition to the default profile, you can store an individual one with AT&W. To alternate between the two profiles enter either ATZ (loads user profile) or AT&F (restores factory profile).

• Every ongoing or incoming call will be terminated.

2.2 AT&V Display Current Configuration

Description: AT&V returns the current parameter setting. The configuration varies depending on whether or not PIN authentication has been done and whether or not Multiplex mode is enabled (see AT+CMUX).

Exec Command Syntax: AT&V[value]

Response: Active Profile (See Section 2.2.1 AT&V responses)

OK

Parameter Description:

<Value>:

0

Notes:

Profile number

• The value of \Q (flow control) is also determined by the AT+IFC command. In case the value set by AT+IFC cannot be represented by a \Q equivalent, \Q255 will be displayed.

The parameters of AT^SMGO can only be displayed after the SMS data from the SIM have been read successfully for the first time. Reading starts after successful SIM authentication has been performed, and may take up to 30 seconds depending on the SIM used. While the read process is in progress, an attempt to read the parameter will result in empty values.

• The parameter of AT+CSDH will only be displayed in SMS text mode, see AT+CMGF.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 19

Chapter 2 – Configuration Commands

2.2.1 AT&V Responses

The following table shows different kinds of responses depending on whether or not the PIN is entered.

Table 2.1: Current configuration on ASC0 channel 1 (example)

PIN authentication done

ACTIVE PROFILE:

E1 Q0 V1 X4 &C1 &D2 &S0 \Q0 \V1

S0:000 S3:013 S4:010 S5:008 S6:000 S7:060 S8:000

S10:002 S18:000

+CBST: 7,0,1

+CRLP: 61,61,78,6

+CR: 0

+FCLASS: 0

+CRC: 0

+CMGF: 0

+CSDH: 0

+CNMI: 0,0,0,0,1

+IFC:3

+IFC:0,0

+ILRR: 0

+IPR: 115200

+CMEE: 2

^SMGO: 0,0

+CSMS: 0,1,1,1

^SACM: 0,”000000”,”000000”

^SLCC: 0

^SCKS: 0,1

^SSET:0

+CREG: 0,1

+CLIP: 0,2

+CAOC: 0

+COPS: 0,0,”operator”

+CGSMS: 3

OK

Note: Table 2.2 has been intentionally omitted.

No PIN authentication

ACTIVE PROFILE:

E1 Q0 V1 X4 &C1 &D2 &S0 \Q0 \V1

S0:000 S3:013 S4:010 S5:008 S6:000 S7:060 S8:000

S10:002 S18:000

+CBST: 7,0,1

+CRLP: 61,61,78,6

+CR: 0

+FCLASS: 0

+IFC:3

+IFC:0,0

+ILRR: 0

+IPR: 115200

+CMEE: 2

^SCKS: 0,1

^SSET:0

OK

2.3 AT&W Stores Current Configuration

Description:

Exec Command Syntax: AT&W[value]

Response: OK

Parameter Values:

<value>

AT&W stores the currently parameters to a user-defined profile in the non-volatile memory.

0

Notes:

Number of the profile

• The user defined profile will be restored automatically after power-up. Use ATZ to restore user profile and AT&F to restore factory settings. Until the first use of AT&W, ATZ works as AT&F.

• User defined profiles in multiplex mode:

AT&W stores all global settings and the current settings of the interface on which the command is executed.

• A list of parameters stored to the user profile can be found in Section 20.5, AT Command Settings storable with

AT&W.

2.4 ATQ Set Result Code Presentation Mode

Description:

Parameter Values:

This parameter setting determines whether or not the TA transmits any result code to the

TE. Information text transmitted in response is not affected by this setting.

Store this parameter with the AT&W command.

Display this parameter with the AT&V command.

Exec Command Syntax: ATQ<n>

Response: If <n> = 0, then OK. Default

If <n> = 1, then (none).

<n>

0

1

DCE transmits result code. Default.

Result codes are suppressed and not transmitted

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 20

Chapter 2 – Configuration Commands

2.5 ATV Set Result Code Format Mode

Description: This command determines the contents of the header and trailer transmitted with AT command result codes and information responses. Possible responses are described in

Section 2.5.1, Verbose and numeric result codes.

Store this parameter with the AT&W command.

Display this parameter with the AT&V command.

Exec Command Syntax: ATV<value>

Response: OK

ERROR

Parameter Value:

<value>

0

1

Information response: <text><CR><LF>

Short result code format: <numeric code><CR>

Information response: <CR><LF><text><CR><LF> Long result code format:

<CR><LF><verbose code><CR>

2.5.1 Verbose and Numeric Result Codes

Verbose format Numeric format

OK 0

CONNECT 1

Meaning

Command executed, no errors established

NO CARRIER

ERROR

NO DIALTONE

BUSY

CONNECT 2400/RLP

CONNECT 4800/RLP

47

48

CONNECT 9600/RLP 49

CONNECT 14400/RLP 50

ALERTING

DIALING

3

4

6

7

Link not established or disconnected

Invalid command or command line too long

No dial tone, dialing impossible, wrong mode

Remote station busy

Link with 2400 bps and Radio Link Protocol

Link with 4800 bps and Radio Link Protocol

Link with 9600 bps and Radio Link Protocol

Link with 14400 bps and Radio Link Protocol

Alerting at called phone

Mobile phone is dialing

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 21

Chapter 2 – Configuration Commands

2.6 ATX Set CONNECT Result Code Format and

Call Monitoring

Description: ATX determines whether or not the TA detects the presence of dial tone and busy signal and whether or not TA transmits particular result codes.

Store this parameter with the AT&W command.

Display this parameter with the AT&V command.

Exec Command Syntax: ATX<value>

Response: OK

ERROR

Parameter Description:

<value>

0

1

CONNECT result code only returned, dial tone and busy detection are both disabled.

Default.

CONNECT <text> result code only returned, dial tone and busy detection are both disabled.

2

3

4

CONNECT <text> result code returned, dial tone detection is enabled, busy detection is disabled.

CONNECT <text> result code returned, dial tone detection is disabled, busy detection is enabled.

CONNECT <text> result code returned, dial tone and busy detection are both enabled.

2.7 AT\ V Set CONNECT Result Code Format

Exec Command Syntax: AT\ V<value>

Response: OK

ERROR

Parameter Description:

<value>

0 CONNECT <text> result code returned without RLP trailer. Default.

1

Notes:

CONNECT <text> result code returned with RLP trailer.

• For circuit-switched data calls only

• Output only if ATX parameter is set with value > 0.

2.8 ATZ Set all Current Parameters to User

Defined Profile

Description:

The user defined profile is stored to the non-volatile memory.

Exec Command Syntax: ATZ[value]

Response:

Parameter Description:

ATZ sets all current parameters to the user profile stored with AT&W. If a connection is in progress, it will be terminated. All defined GPRS contexts which are not activated or not online will be undefined (see AT+CGDCONT, AT+CGQREQ and AT+CGQMIN command).

OK

<value>:

0

Notes:

Reset to user profile

• First the profile will be set to factory default (see AT&F). If there is a valid user profile (stored with AT&W), this profile will be loaded afterwards.

• Any additional commands on the same command line may be ignored. A delay of 300 ms is required before next command is sent, otherwise “OK” response may be corrupted.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 22

Chapter 2 – Configuration Commands

2.9 AT+CFUN Set Phone Functionality

Description: This command serves to control the functionality level of the mobile equipment (ME). It can be used to reset the ME, to choose one of the SLEEP modes, or to return to full functionality.

Intended for power saving, SLEEP mode reduces the functionality of the ME to a minimum and thus minimizes the current consumption. SLEEP mode falls in two categories:

• NON-CYCLIC SLEEP mode <fun>=0

• and CYCLIC SLEEP modes, selectable as <fun>= 7 or 9.

NON-CYCLIC SLEEP mode permanently blocks the serial interface. The benefit of the CYCLIC

SLEEP mode is that the serial interface remains accessible and that, in intermittent wake-up periods, characters can be sent or received without terminating the selected mode. This allows the ME to wake up for the duration of an event and, afterwards, to resume power saving. Please refer to Section

2.8.1, Wake up the ME from SLEEP mode for a summary of all SLEEP modes and the different ways of waking up the module.

For CYCLIC SLEEP mode both the ME and the application must be configured to use hardware flow control. This is necessary since the CTS signal is set/reset every 0.9 to 2.7 seconds in order to indicate to the to the application when the UART is active. The default setting of hardware flow control is AT\Q0 which must be altered to AT\Q3.

For use after restart you are advised to add it to the user profile saved with AT&W.

Test Command Syntax: The test command returns the values of the supported parameters.

AT+CFUN=?

Response: +CFUN: (list of supported <fun>s) , (list of supported <rst>s)

OK

Read Command Syntax: The read command returns the current functionality value.

AT+CFUN?

Response: +CFUN: <fun>

OK

Write Command Syntax: The write command can be used to reset the ME, to choose one of the SLEEP modes or to return to full functionality.

AT+CFUN=<fun>, <rst>

Response: OK

ERROR

+CME ERROR

Parameter Descriptions:

<fun>

0 NON-CYCLIC SLEEP mode:

In this mode, the AT interface is not accessible. Consequently, after setting <fun>=0, do not send further characters. Otherwise these characters remain in the input buffer and may delay the output of an unsolicited result code. The first wake-up event stops power saving and takes the ME back to full functionality level <fun>=1.

1 Full functionality. Default

If the ME is in one of the CYCLIC SLEEP modes you can issue AT+CFUN=1 to stop power saving and return to full functionality.

Keep in mind that, unlike the reset command described below, this action does not restart the ME but only changes the level of functionality. See parameter <rst> for details on the reset.

7 CYCLIC SLEEP mode:

In this mode, the serial interface is shortly enabled during paging. If characters are recognized on the serial interface, the ME stays active for 2 seconds after the last character was sent or received. ME exits

SLEEP mode only, if AT+CFUN=1 is entered.

9 CYCLIC SLEEP mode:

In this mode, the serial interface is shortly enabled while CTS is active. If characters are recognized on the serial interface, the ME stays active after the last character was sent or received for at least the time, which can be configured by AT^SCFG=”PowerSaver/Mode9/Timeout”,<psm9to> (temporary wakeup).

In contrast to SLEEP mode 7 assertion of RTS can also be used to temporarily wake up the ME. In this case too, activity time is at least the time set with AT^SCFG=”PowerSaver/Mode9/Timeout”,<psm9to> .

ME exits SLEEP mode only, if AT+CFUN=1 is entered.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 23

Chapter 2 – Configuration Commands

<rst>

The parameter can only be used if the serial interface is enabled.

Due to the command syntax, you need to enter parameter <fun>, followed by <rst>, where <fun> is only a placeholder and has no effect. See examples below.

0 Placeholder for <fun> as stated above. Default.

1 ME resets and restarts to full functionality. After reset and restart, PIN 1 authentication is necessary

(AT+CPIN). If autobauding is enabled, it is recommended to wait 3 to 5 seconds before entering the first

AT command. For details on autobauding refer to Section 4.9.1, Autobauding.

Unsolicited Result Codes:

URC 1

^SYSSTART

Indicates that the ME has been started and is ready to operate. If autobauding is active (AT+IPR=0), the URC is not generated.

If the ME is configured to enter the Airplane mode after restart or reset the following URC is received on bootup:

“^SYSSTART AIRPLANE MODE”. In this mode, only the AT commands listed in Section 20.4, Availability of AT Commands Depending on Operating Mode of ME can be used. For details please refer to the AT^SCFG command, parameter <mapos>.

Notes:

• When a circuit-switched call is in progress, <fun>=7 or 9 can be activated without terminating the call.

However, setting <fun>=0, during a circuit-switched call immediately disconnects this call.

• To check whether power saving is on, you can query the status with the read command AT+CFUN? only if the module is in full functionality mode or in CYCLIC SLEEP mode. If available, you can also take advantage of the status LED controlled by the SYNC pin (see AT^SSYNC and [2]). With AT^SSYNC you can select different modes of LED signalization during SLEEP modes (See Section 18.6.1., ME Status Indicated by Status LED for details. However, the module can wake up temporarily from power saving without leaving its CYCLIC SLEEP mode (without changing +CFUN “<fun>”); e.g., for a network scan after a loss of radio coverage, or after receipt of serial data during CYCLIC SLEEP mode. During this “temporary wakeup state” the LED will operate as if the ME was in full functionality mode.

• Recommendation: In NON-CYCLIC SLEEP mode, you can set an RTC alarm to wake up the ME and return to full functionality. This is a useful approach because, in this mode, the AT interface is not accessible.

2.9.1 Wake up the ME from SLEEP Mode

A wake-up event is any event that causes the mobile equipment (ME) to draw more current. Depending on the selected mode, the wake-up event either switches the SLEEP mode off and takes the ME back to full functionality AT+CFUN=1, or activates the ME temporarily without terminating the selected SLEEP mode.

Definitions of the state transitions described in Table 2.3:

• Quit: ME exits SLEEP mode.

• Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time after the last character was sent or received on the serial interface.

• No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.

Table 2.3: Wake-up Events in NON-CYCLIC and CYCLIC SLEEP Modes

Event

Ignition line

/RTS0 or RTS1 activation

Selected mode: <fun>=0 Selected mode: <fun>=7 or 9

Quit Mode 7: No effect (RTS is only used for flow control)

Mode 9: Temporary

Unsolicited Result Code (URC)

Incoming voice or data call

Any AT command (incl. outgoing SMS, voice or data call)

Quit

Quit

Not possible (UART disabled) Temporary

Incoming SMS (AT+CNMI is set to 0,0

(this is the default setting)

No effect

Incoming SMS (AT+CNMI is set to 1,1) Quit

Temporary

Temporary

No effect

Temporary

GPRS data transfer

RTC alarm line

AT+CFUN=1

Not possible (UART disabled) Temporary

Quit Temporary

Not possible (UART disabled) Quit

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 24

Chapter 2 – Configuration Commands

2.10 AT^SMSO Switch off Mobile Station

Description: AT^SMSO initiates the power-off procedure. High level of the module’s PWR_IND and the URC “^SHUTDOWN” notifies that the procedure has completed and the module has entered the POWER DOWN mode. Therefore, be sure not to disconnect the operating voltage until PWR_IND is High or until the URC “^SHUTDOWN” is displayed. Otherwise, you run the risk of losing data. For further details on how to turn off the module see the [2].

Exec Command Syntax: ^SMSO

Response(s): ^SMSO: MS OFF, OK

Test Command Syntax: AT^SMSO=?

Response: OK

Unsolicited Result Code:

^SHUTDOWN

Indicates that the power-off procedure is finished and the module will be switched off in less than 1 second.

Notes:

• Do not send any other AT command after AT^SMSO.

• If AT^SMSO is entered on one of the Multiplexer channels, the ME closes the Multiplexer channels, terminates the Multiplexer, and deactivates all other functions. Then the URC “^SHUTDOWN” will be issued on the physical serial interface (ASC0). The URC will be transmitted at the bit rate last activated on ASC0 for use with the Multiplexer driver.

2.11 AT+GCAP Request Complete TA Capabilities

List

Description: AT+GCAP returns a list of additional capabilities.

Exec Command Syntax: AT+GCAP

Response(s): +GCAP: <name>, OK

Test Command Syntax: AT+GCAP=?

Response: OK

Parameter Description:

<name> e.g., +CGSM,+FCLASS

Note:

• +CGSM: The response text shows which GSM commands of the ETSI standard are supported.

2.12 AT+CMEE Mobile Equipment Error Message

Format

Description: AT+CMEE controls the format of the error result codes that indicates errors related to the

Multi-Tech wireless modem’s functionality. Format can be selected between plain

“ERROR” output, error numbers or verbose “+CME ERROR: <err>” and “+CMS ERROR:

<err>” messages.

Possible error result codes are listed in Table 2.6, General “CME ERROR” Codes (GSM

07.07), Table 2.5, GPRS related “CME ERROR” Codes (GSM 07.07) and Table 2.8, SMS related “CMS ERROR” Codes (GSM 07.05).

In Multiplexer mode, the setting applies only to the logical channel where selected. The setting on the other channels may differ.

Test Command Syntax: AT+CMEE=?

Response:

Response:

+CMEE : (list of supported<errMode>s)

OK

Read Command Syntax: AT+CMEE?

Response:

+CMEE : <errMode>

OK

Write Command Syntax: AT+CMEE=<errMode>

OK

ERROR

+CME ERROR: <err>

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 25

Chapter 2 – Configuration Commands

Parameter Description:

<errMode>

0 Disable result code; i.e., only “ERROR” will be displayed.

1 Enable error result code with numeric values.

2 Enable error result code with verbose (string) values.

Example:

To obtain enhanced error messages it is recommended to choose <errMode>=2:

AT+CMEE=2

OK

2.12.1 CME/CMS Error Code Overview

Table 2.4: General “CME ERROR” Codes (GSM 07.07)

<err> Code Text (if AT+CMEE=2)

1

2 no connection to phone phone-adapter link reserved

5

6

10

11

12

PH-SIM PIN required

PH-FSIM PIN required

SIM not inserted

SIM PIN required

SIM PUK required wrong password

SIM PIN2 required

SIM PUK2 required

17

18

32

40

41

42

43

44

24

25

26

27 found failure text string too long invalid characters in text string dial string too long invalid characters in dial string

30 no network service timeout

Network not allowed emergency calls only

Network personalization PIN required

Network personalization PUK required

Network subset personalization PIN required

Network subset personalization PUK required service provider personalization PIN required

45

46

47

48 service provider personalization PUK required

Corporate pe sonalization PIN required

Corporate personalization PUK required

Master Phone Code required

100 unknown

132 service option not supported

133

134

126 requested service option not subscribed service option temporarily out of order

Operation temporary not allowed

258 phone is busy abort

260

261 invalid dial string ss not executed

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 26

Chapter 2 – Configuration Commands

Table 2.5: General “CME ERROR” Codes

<err> Code

772

Text (if AT+CMEE=2)

SIM powered down

Table 2.6: GPRS related “CME ERROR” Codes (GSM 07.07)

<err> Code Text (if AT+CMEE=2)

107

111

112

113

148

149

150

GPRS services not allowed

PLMN not allowed

Location area not allowed

Roaming not allowed in this location area unspecified GPRS error

PDP authentication failure invalid mobile class

Table 2.7: GPRS-related “CMES ERROR” Codes

<err> Code

578

588

594

595

596

607

625

630

632

633

643

644

646

Text (if AT+CMEE=2)

GPRS – unspecified activation rejection

GPRS – feature not supported

GPRS – invalid address length

GPRS – invalid character in address string

GPRS – invalid cid value

GPRS – missing or unknown APN

GPRS – PDP type not supported

GPRS – profile (cid) not defined

GPRS – QOS not accepted

GPRS – QOS validation fail

GPRS – unknown PDP address or type

GPRS – unknown PDP context

GPRS – QOS invalid parameter

Table 2.8: SMS related “CMS ERROR” Codes (GSM 07.05)

<err> Code Text (if AT+CMEE=2)

1

8

Unassigned (unallocated) number

Operator determined barring

10 Call

21 Short message transfer rejected

27 Destination out of service

30 Unknown

38 Network out of order

42 Congestion

47 Resources unavailable, unspecified

50

69

81

95

Requested facility not subscribed

Requested facility not implemented

Invalid short message transfer reference value

Invalid message, unspecified

96

97

98

99

111

Invalid mandatory information

Message type non-existent or not implemented

Message not compatible with short message protocol state

Information element non-existent or not implemented

Protocol error, unspecified

128

129

130

143

144

145

Telematic interworking not supported

Short message Type 0 not supported

Cannot replace short message

Unspecified TP-PID error

Data coding scheme (alphabet) not supported

Message class not supported

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 27

<err> Code

159

160

Text (if AT+CMEE=2)

Unspecified TP-DCS error

Command cannot be actioned

175

176

Unspecified TP-Command error

TPDU not supported

192 SC

193 No SC subscription

194

195

196

197

198

199

SC system failure

Invalid SME address

Destination SME barred

SM Rejected-Duplicate SM

TP-VPF not supported

TP-VP not supported

208

209

210

D0 SIM SMS storage full

No SMS storage capability in SIM

Error in MS

212

213

255

301

SIM Application Toolkit Busy

SIM data download error

Unspecified error cause

SMS service of ME reserved

303 Operation

304 Invalid PDU mode parameter

305

310

Invalid text mode parameter

SIM not inserted

311

312

SIM PIN required

PH-SIM PIN required failure busy

519

520

522

532

534

316

317

SIM PUK required

SIM PIN2 required

318 SIM PUK2 required

320 Memory

321 Invalid memory index

330

331

SMSC address unknown no network service

340 NO +CNMA ACK EXPECTED error

513 unable to store

515 invalid character in address string length

517 invalid character in pdu invalid length or character invalid character in text

Operation temporary not allowed

SIM not ready

Cell Broadcast error unknown

Chapter 2 – Configuration Commands

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 28

Chapter 2 – Configuration Commands

2.13 AT+CSCS Select TE Character Set

Description: The AT+CSCS write command informs the TA which character set <chset> is used by the

TE. This enables the TA to convert character strings correctly between TE and ME character sets. See also Section 1.5, Supported character sets.

Note that when the TA-TE interface is set to 8-bit operation and the used TE alphabet is 7bit, the highest bit will be set to zero.

Test Command Syntax: AT+CSCS=?

Read Command Syntax: AT+CSCS?

Read Response: +CSCS: <chset>

OK

Write Command Syntax: AT+CSCS=[<chset>]

Write Response: OK

Parameter Description:

<chset>

“GSM“

“UCS2“

GSM default alphabet (GSM 03.38 subclause 6.2.1). Default.

This setting may cause software flow control problems since the codes used to stop and resume data flow (XOFF = decimal 19, XON = decimal 17) are interpreted as normal characters.

16-bit universal multiple-octet coded character set (ISO/IEC10646 [32]); UCS2 character strings are converted to hexadecimal numbers from 0000 to FFFF; e.g., “004100620063” equals three 16-bit characters with decimal values 65, 98 and 99, $(AT R97)$

2.14 AT^SCFG Extended Configuration Settings

Description: AT^SCFG queries and configures various settings of the Multi-Tech wireless modem.

AT^SCFG read command returns a list of all supported parameters and their current values.

The write command queries a configuration parameter (if no value is entered) or sets its value(s).

Input of parameter names is always coded in GSM character set; parameter values are expected to be given as specified via AT+CSCS.

The following error messages may be returned to the AT^SCFG write commands:

• “+CME ERROR: operation temporary not allowed”

Change of parameter value(s) temporarily not allowed.

• “+CME ERROR: invalid index”

Invalid parameter name or value(s).

• “+CME ERROR: invalid characters in text string”

Character set conversion of parameter value(s) failed.

• “+CME ERROR: memory failure”

Could not allocate necessary memory or storing a parameter failed.

• “+CME ERROR: operation not allowed”

Change of parameter value(s) not allowed

• “+CME ERROR: unknown”

Other error

Test Command Syntax: AT^SCFG=?

Responses:

^SCFG: “GPRS/ATS0withAttach”, (list of supported <gs0aa>S)

^SCFG: “GPRS/AutoAttach”, (list of supported <gaa>S)

^SCFG: “GPRS/RingOnIncomingData”, (list of supported <groid>s)

^SCFG: “MEopMode/Airplane”, (list of supported <map>s)

^SCFG: “MEopMode/Airplane/OnStart”, (list of supported <mapos>s)

^SCFG: “PowerSaver/Mode9/Timeout”, (list of supported <psm9-to>s)

^SCFG: “Radio/Band”, (list of supported <rbp>s), (list of supported <rba>s)

^SCFG: “Radio/OutputPowerReduction”, (list of supported <ropr>s)

^SCFG: “URC/CallStatus/CIEV”, (list of supported <succ>s)

^SCFG: “URC/CallStatus/SLCC”, (list of supported <sucs>s)

^SCFG: “URC/Datamode/Ringline”, (list of supported <udri>s)

^SCFG: “URC/Ringline”, (list of supported <uri>s)

^SCFG: “URC/Ringline/ActiveTime”, (list of supported <urat>s)

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 29

Chapter 2 – Configuration Commands

Read Command Syntax: AT^SCFG?

Read Responses:

^SCFG: “GPRS/ATS0withAttach”, <gs0aa>

^SCFG: “GPRS/AutoAttach”, <gaa>

^SCFG: “GPRS/RingOnIncomingData”, <groid>

^SCFG: “MEopMode/Airplane”, <map>

^SCFG: “MEopMode/Airplane/OnStart” <mapos>

^SCFG: “PowerSaver/Mode9/Timeout”, <psm9-to> (changed)

^SCFG: “Radio/Band”, <rbc>, <rba>

^SCFG: “Radio/OutputPowerReduction”, <ropr>

^SCFG: “URC/CallStatus/CIEV”, <succ>

^SCFG: “URC/CallStatus/SLCC”, <sucs>

^SCFG: “URC/Datamode/Ringline”, <udri>

^SCFG: “URC/Ringline”, <uri>

^SCFG: “URC/Ringline/ActiveTime”, <urat>

OK

Write Command for GPRS ATS0 with Automatic Attach: AT^SCFG=”GPRS/ATS0/withAttach”[, <gs0aa>]

Write Responses:

^SCFG: “GPRS/ATS0/withAttach”, <gs0aa>

OK

ERROR

+CME ERROR

Write Command for GPRS Attach: AT^SCFG=”GPRS/AutoAttach”[, <gaa>]

Write Responses:

^SCFG: “GPRS/AutoAttach”, <gaa>

OK

ERROR

+CME ERROR

Write Command for Ring on Incoming GPRS IP Data Packets:

AT^SCFG=”GPRS/RingOnIncomingData”[,<groid>]

Write Responses:

^SCFG: “GPRS/RingOnIncomingData”, <groid>

OK

ERROR

+CME ERROR

Write Command for Enable/Disable Airplane Mode During Operation

AT^SCFG="MEopMode/Airplane"[, <map>]

Write Responses:

^SCFG: "MEopMode/Airplane", <map>

OK

ERROR

+CME ERROR

Write Command for Airplane Mode upon ME Restart

AT^SCFG="MEopMode/Airplane/OnStart"[, <mapos>]

Write Responses:

^SCFG: "MEopMode/Airplane/OnStart", <mapos>

OK

ERROR

+CME ERROR

Write Command for Query/Set Timeout Value for Power Saving Mode 9:

AT^SCFG=”PowerSaver/Mode9/Timeout”[, <psm9to>]

Write Responses:

^SCFG: “PowerSaver/Mode9/Timeout”, <psm9to>

OK

ERROR

+CME ERROR

Write Command for Radio Ouput Power Reduction: AT^SCFG=”Radio/OutputPowerReduction”[, <ropr>]

Write Response(s):

^SCFG: “Radio/OutputPowerReduction”, <ropr>

OK

ERROR

+CME ERROR

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 30

Chapter 2 – Configuration Commands

Write Command for Radio Band Selection: AT^SCFG=”Radio/Band”[, <rbp>][, <rba>]

Write Response(s):

^SCFG: “Radio/Band”, <rbp>, <rba>

OK

ERROR

+CME ERROR

Write Command for Configuration of URC “+CIEV: call” Call Status Indication:

AT^SCFG=”URC/CallStatus/CIEV”[, <succ>]

Write Responses:

^SCFG: “URC/CallStatus/CIEV”, <succ>

OK

ERROR

+CME ERROR

Write Command for Configuration of URC “^SLCC” Call Status Indication:

AT^SCFG=”URC/CallStatus/SLCC”[, <sucs>]

Write Responses:

^SCFG: “URC/CallStatus/SLCC”, <sucs>

OK

ERROR

+CME ERROR

Write Command for URC Indication in Datamode via Ring Line:

AT^SCFG=”URC/Datamode/Ringline”[, <udri>]

Write Responses:

^SCFG: “URC/Datamode/Ringline”, <udri>

OK

ERROR

+CME ERROR

Write Command for URC Indication via Ring Line:

AT^SCFG=”URC/Ringline”[, <uri>]

Write Responses:

^SCFG: “URC/Ringline”, <uri>

OK

ERROR

+CME ERROR

Write Command for Duration of Active RING Line for URC Indications:

AT^SCFG=”URC/Ringline/ActiveTime”[, <urat>]

Write Responses:

^SCFG: “URC/Ringline/ActiveTime”, <urat>

OK

ERROR

+CME ERROR

Unsolicited Result Codes:

^SYSSTART AIRPLANE MODE

This URC is issued each time the Airplane mode is activated, no matter whether Airplane mode is set with parameter <map>="on" or <mapos>="on". The URC notifies the user that only the AT commands supported in

Airplane mode are accessible. After leaving the Airplane mode the URC "^SYSSTART" indicates that the ME has returned to Normal mode and the full set of AT commands is accessible again.

Parameter Descriptions:

<gs0aa> GPRS ATS0 with Attach

This parameter can be used to control the behaviour of ATS0.

Parameter is global for all interfaces, volatile and will not be reset by AT&F.

“on“ When ATS0=<n> (<n>>0) is received, the MT will attempt to perform a GPRS attach. This is the powerup default value of this parameter.

“off“ When ATS0=<n> (<n>>0) is received, the MT will not attempt to perform a GPRS attach.

<gaa> GPRS with Auto Attach

This parameter can be used to control whether the ME will perform a GPRS attach immediately after registering to the network or not. If the setting is changed to “enabled” and the ME is not attached yet, it will not initiate an attach immediately but after the next registration to the network.

Parameter is global for all interfaces, non volatile and will not be reset by AT&F.

“disabled“ GPRS auto attach is disabled. Default.

“enabled“ GPRS auto attach is enabled.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 31

Chapter 2 – Configuration Commands

<groid> Ring on incoming GPRS IP data packets

This parameter can be used to control the behavior of the RING line for incoming IP packets in GPRS online mode.

Parameter is local for the interface, volatile and will not be reset by AT&F.

“on“ If ME is in power saving mode 7 or 9 (see AT+CFUN) and hardware flow control is in use (AT\Q3) and RTS line is inactive and there are incoming IP packets for a GPRS context which is online, then the RING line will be activated once, for a time which is configured by the parameter

“URC/Ringline/ActiveTime” (<urat>). The RING line which will be used, can be configured by the parameter “URC/Ringline” (<uri>).

“off“ RING line is not activated for incoming IP packets. This is the powerup default value of this parameter; it is not stored at power down.

<map> MEopMode/Airplane: Enable/Disable Airplane Mode During Operation

The two parameters <map> and <mapos> can be used to enable/disable the Airplane mode. Airplane mode shuts down the radio part of the ME (PA and receiver), causes the ME to log off from the GSM/GPRS network and disables all AT commands whose execution requires a radio connection. A list of AT commands supported during Airplane mode can be found in Section 20.4, Availability of AT Commands Depending on Operating Mode of ME. The benefit of Airplane mode is that, at locations where no RF emission is allowed (typically airplanes, hospitals etc.), the subscriber can continue using network-independent features rather than powering off the entire device (e.g. a PDA or smartphone).

If the subscriber tries to use an AT command not available in Airplane mode the response "+CME ERROR:

Unsupported AT command" is returned.

Parameter <map> allows entering or leaving the Airplane mode any time during operation, eliminating the need to enter the SIM PIN again. It can be used no matter whether the parameter <mapos> is "on" or "off".

Parameter <map>is global for all interfaces, volatile and will not be reset by AT&F.

“on“ Activates Airplane mode and shuts down the radio part of the ME. The URC "^SYSSTART

“off“

AIRPLANE MODE" appears.

Deactivates Airplane mode, wakes up the radio part of the ME and restores access to networkdependent AT commands. The URC "^SYSSTART" appears.

<mapos> MEopMode/Airplane: Airplane Mode Upon ME Restart

There are two ways to enter Airplane mode upon restart: One is using AT^SCFG with <mapos> as described below.

Another approach is configuring the ME to restart into Airplane mode at a scheduled time. In this case, use the

AT+CALA command, set an alarm time and then switch the ME off. When the alarm time is reached the ME wakes up to Airplane mode, no matter whether <mapos> was set "on" or "off".

Parameter <mapos> is global for all interfaces, non volatile and will not be reset by AT&F.

“on“ Causes the ME to enter the Airplane mode each time the ME is restarted or reset.

“off“

After restart or reset, the URC "^SYSSTART AIRPLANE MODE" appears and parameter <map> is

"on". The SIM PIN can be entered using the AT+CPIN command. This enables the ME to read data from the SIM and give access to SIM PIN dependent AT commands which are available in Airplane mode, such as phonebook commands or several SMS commands. To notify the user when SIM data are accessible it is recommended to activate the "^SSIM READY" URC and store its presentation mode to the user profile with AT&W.

To return from Airplane mode to Normal mode set the parameter <map> to "off" as described above. If PIN authentication was already done, the ME will try now to register to the GSM network.

Airplane mode will not be activated after ME restart or reset. Default.

<psm9to> Power Saving Mode 9 Timeout

This parameter can be used to query or configure the wake up time for power saving mode 9 (see AT+CFUN with parameter <fun>=9). The granularity of the timeout value is 100ms (i.e. a value of 10 equal 1 second).

The minimum timeout value that can be applied is 5, but accuracy is only guaranteed for timeout values greater than 20.

Parameter is global for the ME, volatile and will not be reset by AT&F.

5.....36000 (default is 20)

<rba> Allowed Radio Band(s)

The parameters <rba>, <rbp> and <rbc> allow the subscriber to set and query preferences for selecting frequency bands.

Before changing <rba> or <rbp> ensure that no network activity occurs. The write command cannot be executed when making a call or sending/receiving short messages.

Execution of the write command causes the ME to deregister from and re-register to the network, no matter whether the selected <rbp> or <rba> setting really changes. Therefore, it is useful to have the URC “+CREG” enabled.

The status of the SIM PIN authentication remains unchanged, eliminating the need to enter the SIM PIN again after the change.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 32

Chapter 2 – Configuration Commands

The parameter <rba> determines the maximum range of the bands allowed. The value may be one of the single bands listed below or all valid combinations from the values 1, 2, 4 and 8. Thus, the value range of

<rba> is “1”..”15”. To select or deselect a band calculate the sum of the values of all desired bands and enter the resulting value. For example, for 1800 MHz (2) and 850 MHz (8) please enter the value (10).

Parameter <rba> is global for the ME, non-volatile and will not be reset by AT&F.

“1“

“2“

“4“

“8“

“3“

GSM 900 MHz

GSM 1800 MHz

GSM 1900 MHz

GSM 850 MHz

GSM 900 MHz + GSM 1800 MHz

GSM 900 MHz + GSM 1900 MHz “5“

“10“ GSM 850 MHz + GSM 1800 MHz

“12“ GSM 850 MHz + GSM 1900 MHz

“15“ all bands

<rbp> Preferred Radio Band(s)

The parameter <rbp> may be one of the single bands or one of the four dual-band combinations listed below.

All preferred bands must be contained in the range of allowed bands (see <rba>), invalid combinationsare not accepted. To give priority to a certain single band or band combination and suppress all others simply select the same value both for <rbp> and <rba>.

<rbp> primarily serves to trigger the network search; i.e., it is only used one time for searching and selecting a network. As the currently used band depends on the availability of the allowed networks, the value indicated by

<rbc> may be different from <rbp>. Also, the next time a network search is necessary (for example, after restart) the ME will first try to reselect the network last used, which may be different from the value of <rbp> last given.

Therefore, the setting of <rbp> will not be saved.

The value range of <rbp> is “1...12”, but only the band(s) selections listed below are allowed. Trying to set an unsupported value will be denied with “ERROR”. To select or deselect a band calculate the sum of the values of all desired bands and enter the resulting value. For example, for GSM 1800 MHz (2) and GSM 850 MHz (8) please enter the value (10).

“1“

“2“

“4“

“8“

“3“

“5“

“10“

“12“

GSM 900 MHz

GSM 1800 MHz

GSM 1900 MHz

GSM 850 MHz

GSM 900 MHz + GSM 1800 MHz

GSM 900 MHz + GSM 1900 MHz

GSM 850 MHz + GSM 1800 MHz

GSM 850 MHz + GSM 1900 MHz

<rbc> Currently Selected Radio Band(s)

The band(s) indicated with <rbc> are all allowed bands found at a location area. This means, if prompted to select a network the ME will search for these networks only. The value can be either a single band or a dualband combination.

<rbc> is only a response parameter returned either after sending the read command AT^SCFG? or writing

AT^SCFG=”Radio/Band”.

In addition to <rbc> and to allow the subscriber to be notified whenever the selected band changes it is recommended to activate the “+CIEV” (see Section 3.3, AT^SIND).

“1“

“2“

“4“

“8“

“3“

“5“

“10“

“12“

GSM 900 MHz

GSM 1800 MHz

GSM 1900 MHz

GSM 850 MHz

GSM 900 MHz + GSM 1800 MHz

GSM 900 MHz + GSM 1900 MHz

GSM 850 MHz + GSM 1800 MHz

GSM 850 MHz + GSM 1900 MHz

<ropr> Radio Output Power Reduction

According to 3GPP Rel99, output power reduction for multiple TX slots is a mandatory feature. The amount of power reduction is configurable up to 3.0dB for 2TX, 4.8dB for 3Tx to 6dB for 4TX. To optimize heat dissipation, power consumption, and SAR values, it is recommended to use full power reduction (value “3”).

The parameter is global for all interfaces, non volatile, and will not be reset by AT&F.

“1“ Medium Reduction at GMSK and 8PSK (0dB for 1TX and 2TX, 1.8dB for 3TX and 3dB reduction 4TX

“2“

“3“

Medium Reduction at GMSK (1TX 0dB, 2TX 3dB, 3TX 4.8dB and 4TX 6dB reduction) and

Full Power at 8PSK (1TX and 2TX 0dB reduction)

Maximal Reduction at GMSK and 8PSK (1TX 0dB, 2TX 3dB, 3TX 4.8dB and 4TX 6dB reduction). Default.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 33

Chapter 2 – Configuration Commands

<succ> CIEV Call Status Indication

This parameter can be used to control the behaviour of URC “+CIEV: call”. See also AT+CIND, AT+CMER and

Section 7.1, Call Status Information.

Parameter is global for all interfaces and will not be reset by AT&F.

“restricted“ URC “+CIEV: call” will be issued only when a Call Status transition ends in state “active” or

“unknown”. This is the powerup default value of this parameter; it is not stored at power down.

(see Section 7.1, Call Status Information) for a call in the list of active calls.

“verbose“ URC “+CIEV: call” will be issued when any state transition (including transitions beginning or ending in state “unknown”) occurs in the list of active calls, or when a traffic channel is established.

<sucs> SLCC Call Status Indication

This parameter can be used to control the behaviour of URC “^SLCC”. See also AT^SLCC and Section 7.1,

Call Status Information.

Parameter is global for all interfaces and will not be reset by AT&F.

“restricted“ URC “^SLCC” will be issued only when a Call Status transition ends in state “active” or

“unknown” (see Section 7.1, Call Status Information) for a call in the list of active calls.

“verbose“ URC “^SLCC” will be issued when any state transition (including transitions beginning or ending in state “unknown”) occurs in the list of active calls, or when a traffic channel is established. This is the powerup default value of this parameter; it is not stored at power down.

<uri> URC RING Line

This parameter can be used to control the behaviour of the RING line to indicate URCs (both for idle interfaces and, if configured by the parameter “URC/Datamode/Ringline”, if link is reserved) and, if configured, the indicator for incoming IP packets (see parameter “GPRS/RingOnIncomingData” (<groid>).

Parameter is local for the interface, volatile and will not be reset by AT&F.

“off“ URC is not indicated by RING.

“local“ URC will be indicated by an activated RING line of the interface on which the URC appears. This is the powerup default value of this parameter; it is not stored at power down.

<udri> URC Datamode RING Line

This parameter specifies whether RING or BREAK is used for the signaling of URCs when the TA-TE link is reserved (e.g., during circuit-switched data calls, fax connections, in GPRS data mode or during the execution of an AT command).

Parameter is global for all interfaces, volatile and will not be reset by AT&F.

“off“ URC will be indicated by BREAK. Off is the powerup default value; it is not stored at power down.

“on“ URC is indicated by an active RING line for a time. It is configured by “URC/Ringline/ActiveTime”

(<urat>). The RING line, which will be used, can be configured by “URC/Ringline” (<uri>).

<urat> URC RING line Active Time

This parameter can be used to control how long the RING line is activated to indicate URCs (both for idle interfaces and, if configured by “URC/Datamode/Ringline” (<udri>), to indicate if link is reserved) and, if configured by “GPRS/RingOnIncomingData”, to indicate incoming GPRS IP data packets (<groid>).

Parameter is global for all interfaces, volatile and will not be reset by AT&F.

“0“

“1“

RING line will be activated for a time between 4.6 and 9.2 ms.

RING line will be activated for about 100ms.

“2“ RING line will be activated for about 1s. This is the powerup default value of this parameter; it is not stored at power down.

Notes

• Parameters “GPRS/ATS0/withAttach” (<gs0aa>) and “GPRS/RingOnIncomingData” (<groid>) are available only for modules supporting GPRS.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 34

Chapter 2 – Configuration Commands

Example

Usage of “URC/Ringline” and “URC/Datamode/Ringline”:

Switch to GSM character set. AT+CSCS=”GSM”

OK

AT^SCFG? Query all parameters.

...

^SCFG:”URC/Datamode/Ringline”,”off”

^SCFG:”URC/Ringline”,”local”

While the TA-TE link is reserved URCs will be indicated by BREAK.

URCs on this interface will be indicated by Ring line associated to the interface (e.g. RING0 for ASC0).

...

OK

AT^SCFG=”URC/Datamode/Ringline”,”on”

^SCFG:”URC/Datamode/Ringline”,”on” While the TA-TE link is reserved URCs will be indicated by an activated “local” Ring line.

OK

AT^SCFG=”URC/Ringline”,”asc0”

^SCFG:”URC/Ringline”,”asc0” URCs on this interface will be indicated by an activated RING0 no matter whether or not the TA-TE link is reserved.

OK

AT^SCFG=”URC/Datamode/Ringline”,”off”

^SCFG:”URC/Datamode/Ringline”,”off” URCs on this interface will be indicated by an activated RING0 if the

TA-TE link is not reserved and by BREAK if the TA-TE link is reserved.

OK

AT^SCFG=”URC/Ringline”

^SCFG:”URC/Ringline”,”off”

OK

Disable any Ring line indication for URCs on this interface.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 35

Chapter 3 – Status Control Commands

Chapter 3. Status Control

Commands

The AT Commands described in this chapter allow the external application to obtain various status information from the Multi-Tech wireless modem.

3.1 AT+CMER Mobile Equipment Event Reporting

Description: This command controls details of the “+CIEV” URC presentation related to AT^SIND and

AT+CIND. If registered via these commands the URCs are sent whenever a value of the related indicator changes.

In addition, AT+CMER controls “^SLCC” URCs related to AT^SLCC. For details refer to Call Status

Information, AT^SLCC and AT^SCFG, parameter <sucs>.

The read command returns the URC presentation mode <mode> and among others, the indicator event reporting status <ind>.

The write command enables and disables the presentation of “+CIEV: <indDescr>, <indValue>1[,

<ind-Value>2]” URCs. <indDescr> refers to the name of a “+CIEV” indicator and <indValue> is the new value of this indicator. After AT+CMER has been switched on, URCs for all registered indicators will be issued. See examples provided in Section 3.2, AT+CIND and Section 3.3,

AT^SIND.

Test Command Syntax: AT+CMER=?

Test Response: +CMER: (list of supported<mode>s), (list of supported <keyp>s), (list of supported

<disp>s), (list of supported <ind>s), (list of supported <bfr>s)

OK

Read Command Syntax: AT+CMER?

Read Response: +CMER: <mode>, <keyp>, <disp>, <ind>, <bfr>

OK

Write Command Syntax: AT+CMER=[<mode>[, <keyp>[, <disp>[, <ind>[, <bfr>]]]]]

Read Response: OK

ERROR

+CME

Unsolicited Result Code:

+CIEV: <indDescr>, <indValue>1[, <indValue>2]

A value of an indicator has changed.

Parameter Description:

<mode>

0 Discard “+CIEV” and “^SLCC” URCs. Default.

1 Discard “+CIEV” and “^SLCC” URCs when TA-TE link is reserved (e.g., in online data mode). Otherwise, they are forwarded directly to the TE.

2 Buffer “+CIEV” and “^SLCC” URCs in the TA while TA-TE link is reserved; e.g., in online data mode and flush them to the TE afterwards. Otherwise, they are forwarded directly to the TE.

3 Forward “+CIEV” and “^SLCC” URCs directly to the TE. If the Multi-Tech wireless modem is in online data mode, URCs are signaled via sending BREAK (100ms) and stored in a buffer. Once it is back in command mode (e.g., after +++ was entered), all URCs stored in the buffer will be output.

<keyp>

0 Keypad event reporting is not supported by the Multi-Tech wireless modem. Default.

<disp>

0 Display event reporting is not supported by the Multi-Tech wireless modem. Default.

<ind>

0 Disable indicator event reporting. Default.

2 Enable indicator event reporting.

<bfr>

0 TA buffer of URCs defined within this command is cleared when <mode> 1..3 is entered. Default.

<indDescr>

Name of indicator; for a list of all supported indicators please refer to AT+CIND and AT^SIND.

<indValue>

Value of indicator; for a list of all values for the supported indicators please refer to AT+CIND and AT^SIND.

Note:

If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0) avoid different settings for routing and indicating SMS. For example, if messages shall be routed directly to one instance of the TE (set with AT+CNMI,

AT^SSDA), it is not possible to activate the presentation of URCs with AT+CMER or AT+CNMI on another instance.

Any attempt to activate settings that conflict with existing settings on another interface, will result in CME ERROR, or accordingly CMS ERROR.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 36

Chapter 3 – Status Control Commands

3.2 AT+CIND Indicator control

Description: The AT+CIND command controls the presentation of Indicator Event Reports related to various functions such as signal quality, service availability, sound generation, indication of unread short messages, full SMS storage, call in progress or roaming activities.

Use of AT+CIND has become outdated. Rather we recommend the more powerful AT^SIND command which is easier to use and provides additional indicators. All indicators provided by

AT+CIND can be handled with AT^SIND as well.

AT+CIND supports two ways to get the values related to indicators:

• One approach is to query the current status of each indicator by using the read command

AT+CIND?. It returns the status no matter whether the indicator has been registered with the write command AT+CIND=[<mode>[,<mode>[,...]]].

• The other way is an event-driven notification based on the “+CIEV” URCs. In this case, the ME will automatically send a message to the application, whenever the value of an indicator changes. The application should be designed to react adequately when receiving a URC.

The presentation of these URCs depends on two settings:

∗ The indicators must be registered with the write command

AT+CIND=[<mode>[,<mode>[,...]]]. When the ME is switched on all of them are in registered mode. Any indicator can be excluded if deregistered with <mode>=0. To register or deregister an indicator the AT+CIND write command requires to type the value <mode>=1 or 0 exactly at the position where the indicator is located in the list.

This is not necessary with AT^SIND which allows to specify indicators by name. See examples below.

∗ The presentation of the registered indicators must be enabled with AT+CMER.

Test Command Syntax: AT+CIND=?

Test Response: +CIND: (<indDescr>, list of supported <indValue>s)[, (<indDescr>, list of supported

<indValue>s)[,...]]

OK

Read Command Syntax: AT+CIND?

Read Response: +CIND: <indValue>[, <indValue>[, ...]]

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CIND=<mode>[, <mode>[, ...]]

Write Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<indValue>

Integer type value, which shall be in range of corresponding <indDescr>

<indDescr>

String values and their <indValue> ranges.

More indications are available via AT^SIND. Therefore use of AT^SIND for control of all indications is recommended.

The following indications are accessible via AT+CIND:

“signal“ Signal quality (0..7). The indicated value is the bit error rate of the signal received. Bit errors are estimated values. See also AT+CSQ.

“service“

“sounder“

Service availability (0-1)

0: Not registered to any network

1: Registered to home network or, if “roam”=1 then registered to another network

Sounder activity (0-1)

Reports every event that causes the ME to generate a tone.

Value 1 means for example:

Incoming call – ME is ringing. Note that the URC “+CIEV: sounder” will be output only if ringing tones are activated with AT^SRTC.

Waiting call – ME generates waiting call tone (if call waiting is enabled).

Outgoing call – ME generates Call Progress tone.

Outgoing call – ME generates BUSY tone.

The value changes to 0 when the tone stops.

“message“ Unread short message at memory location <mem1> (0-1); refer to AT+CPMS

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 37

Chapter 3 – Status Control Commands

“call“

“roam“

“smsfull“

Call in progress (0-1). Indicator value is “1” if at least one call is in state “active” or “held”.

Depending on the parameter <succ> selected with AT^SCFG the indicator “call” will be issued

• when a state transition ends in state “active” or state “unknown”, if <succ>=”restricted”,

• when any state transition (including transitions beginning or ending in state “unknown”) occurs in the list of active calls or when a traffic channel is established, if

<succ>=”verbose”.

Also refer to Section 7.1, Call Status Information.

Roaming indicator (0-1)

0: Registered to home network or not registered

1: Registered to other network

A short message memory storage in the MT has become full (1) or memory locations are available (0); i.e., range is (0-1)

“rssi“ Received signal (field) strength (0..5).

0: signal strength <= -112 dbm

1-4: signal strength in 15 dbm steps

5: signal strength >= -51 dbm

Received signal (field) strength can also be obtained with AT+CSQ. However, the signal strength is scaled to value range 0..31 by this command.

<mode>

0

1

Indicator is deregistered. The indicator will not be presented as “+CIEV” URC, but can be queried with AT+CIND?.

Indicator is registered, indicator event report allowed. Default. This is also the powerup default of this parameter; it is not stored at power down.

Notes:

• Due to its restrictive value range, indicator “call” does not clearly reflect specific call states (such as alerting, active, held etc.), but rather serves to trigger the application to retrieve the new call status from the list of current calls with the AT commands AT^SLCC, AT+CLCC or AT^SCNI.

• If AT^SCFG setting <succ>=”verbose”, indicator “call” will be issued also when a traffic channel is established, or when a call enters states “terminating” or “dropped” (see Call Status Information). In these cases, the relevant information about the cause of the display is available only from AT command AT^SLCC.

Examples

Example 1

^SYSSTART

AT+CPIN=9999

OK

AT+CIND?

+CIND: 5,1,0,0,0,0,0 The battery is either full or no battery is connected to the ME. The bit error rate of the signal quality is not available (since there is no call in progress). The ME is registered to its home network.

OK

AT+CMER=2,0,0,2

OK

+CIEV: battchg,5

+CIEV: service,1

+CIEV: sounder,0

+CIEV: message,0

+CIEV: call,0

+CIEV: roam,0

+CIEV: smsfull,0

+CIEV: rssi,5

ATD0123456;

OK

+CIEV: sounder,1

+CIEV: call,1

+CIEV: sounder,0

+CIEV: call,0

NO CARRIER

AT+CIND=,,,0,,0

OK

ATD0123456;

OK

NO CARRIER

Example 2

Deactivation of indicator “sounder” via AT+CIND

AT+CIND=? Query the current status of indicators.

+CIND: 5,1,0,1,0,0,0,4

OK

AT+CIND=,,,0

OK

Example 3

Deactivation of indicator “sounder” via AT^SIND

AT^SIND=”sounder”,0

^SIND: sounder,0,0

OK

Now activate the Indicator Event Report with AT+CMER.

Full receive signal strength.

Make a call.

A set of “+CIEV” URCs is received.

Called party hangs up.

Deregister the indicators “sounder” and “call”.

Dial the same call.

This time, no URCs are displayed.

Called party hangs up.

To deactivate indicator “sounder” (= fourth item in list of indicators).

To deactivate indicator “sounder”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 38

Chapter 3 – Status Control Commands

3.3 AT^SIND Extended Indicator Control

Description: Designed for extended event indicator control AT^SIND

• offers greater flexibility than the standard command AT+CIND,

• offers several extra indicators,

• can show the current status of all indicators supported by AT+CIND and AT^SIND,

• can be used to register or deregister the indicators of both commands,

• displays all indicator event reports via “+CIEV” URCs.

Presentation mode of the generated URCs is controlled via AT+CMER.

The AT^SIND read command provides a list of all indicators supported by AT+CIND and AT^SIND.

Each indicator is represented with its registration mode and current value.

The AT^SIND write command can be used to select a single indicator in order to modify its registration and to view the current value.

Test Command Syntax: AT^SIND=?

Test Response: ^SIND: (<indDescr>, list of supported <indValue>s)[, (<indDescr>, list of supported

<indValue>s)[,...]], (list of supported <mode>s)

OK

Read Command Syntax: AT^SIND?

Read Response: ^SIND: <indDescr>, <mode>, <indValue>

[^SIND: <indDescr>, <mode>, <indValue>]

...

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT^SIND=<indDescr>, <mode>

Write Response: ^SIND: <indDescr>, <mode>, <indValue>

In case of: <indDescr>=”eons” and <mode>=2

^SIND: <indDescr>, <mode>, <indValue>, <eonsOperator>, <servProvider>

In case of: <indDescr>=”nitz” and <mode>=2

^SIND: <indDescr>, <mode>, <nitzUT>, <nitzTZ>, <nitzDST>

OK

ERROR

+CME ERROR: <err>

Unsolicited Result Codes:

URC 1

Format of the standard indicator:

+CIEV: <indDescr>, <indValue>

Value related to an indicator has changed.

URC 2

Format of the Voice Message indicator, if the number of waiting messages is delivered by the network:

+CIEV: <indDescr>, <indValue>, <vmCounter>

If the number of waiting messages is not delivered the standard indicator applies.

URC 3

Format of the “eons” indicator

+CIEV: <indDescr>, <indValue>, <eonsOperator>, <servProvider>

One URC is issued for each new LAI (Location Area Information) broadcast by the network.

URC 4

Format of the “nitz” indicator:

+CIEV: <indDescr>, <nitzUT>, <nitzTZ>, <nitzDST>

URC 5

Format of the “msclass” indicator:

+CIEV: <indDescr>, <indValue>

Parameter Descriptions:

<indDescr>

String values and their <indValue> ranges.

All indicators supported by AT+CIND are accessible with this command, too. A detailed description of these indicators can be found there.

The following indicators are accessible via AT^SIND only:

“audio“ Activity of the built-in audio unit.

0 Audio unit not active.

1 Value 1 means for example:

Outgoing voice call: Indicator appears when dialing starts.

Incoming voice call: Indicator appears prior to the RING result code.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 39

Chapter 3 – Status Control Commands

“vmwait1“ Voice Message Waiting Indication for line 1

0 Notifies that no new voice message is available, and is provided by the service center to clear the voice message indication after the subscriber has retrieved all voice messages.

1 Notifies the subscriber that the mailbox contains one or several messages.

“vmwait1” and “vmwait2” indicate the receipt of a special short message with a Voice

Message Waiting Indicator. The service must be provisioned by the operator.

The numbers 1 or 2 in “vmwait1” and “vmwait2” are related to the two lines of the Alternate

Line Service (ALS), also defined in CPHS Phase 2 standard. For further details refer to the

AT^SALS command.

The presentation mode of the indicator varies with the operator: If more than one message are waiting, some operators only indicate the first one, others deliver the indicator each time a new voice message is put into the mailbox.

After the subscriber has retrieved all voice messages the service center automatically sends another message indication which provides the value 0.

Some operators may also send the number of waiting voice messages along with the indication. In this case, this number will be displayed by the Multi-Tech wireless modem as part of the URC. For example, “+CIEV: vmwait1,1,5” notifies that five new voice messages are waiting. However, it should be noted that neither the read command AT^SIND? nor the write command AT^SIND=<mode>,2 display the number of waiting messages.

The “vmwait” indicators do not apply if a network provider signals new voice mail(s) via standard SMS. In this case the indicator “message” will be displayed (see AT+CIND).

“vmwait2“ Voice Message Waiting Indication for line 2

0 See description of “vmwait1”.

1 See description of “vmwait1”.

“ciphcall“ Ciphering Status Change Indication

0 Current call or SMS is not ciphered.

1 Current call or SMS is ciphered.

As stated in GSM specifications 02.07 and 02.09 the ciphering indicator feature allows the

Multi-Tech wireless modem to detect that ciphering is not switched on and to indicate this to the user.

The ciphering indicator feature may be disabled by the home network operator setting data in the “administrative data” field (EFAD) in the SIM, as defined in GSM 11.11.

If this feature is not disabled by the SIM, then whenever a connection is in place, which is, or becomes unenciphered, an indication shall be given to the user. This enables the user’s decision how to proceed.

Read command returns valid ciphering status only if a call is in progress or active.

“eons“

If EF

AD

setting disables the ciphering indicator feature read command always indicates a ciphered link and no URC presentaion will take place.

The following restrictions apply if the same serial channel is used for AT^SIND

“ciphcall” indication and for the action triggering this URC. In general, the recommended solution is to use a dedicated channel for all status signalling via URCs.

• If an unciphered mobile originated SMS is performed, AT^SIND “ciphcall”

URCs on the same serial channel will be issued after the related “OK” and indicate the ciphering state at this time.

• If an unciphered mobile originated data call is performed, AT^SIND “ciphcall”

URCs on the same serial channel will be issued after the interface is not longer blocked by the call (call is released or temporarily stopped) and indicate the ciphering state at this time.

Enhanced Operator Name String (EONS) Indication.

The Enhanced Operator Name String indicator feature allows the Multi-Tech wireless modem to output various operator names for different PLMN identities via URC. It also allows the output of a different operator name based on a subset of the registered network by using a range of Location Area Codes (LACs) or a single LAC.

The presentation of the “eons” indicator is determined by network activity. For example, the indicator appears every time a location update occurs or a NITZ information is sent, no matter whether or not the status of the EONS information has changed. This means that the same EONS information may be reported several times.

The EONS tables are stored in the SIM card and will be read at power-up.

This is a list of the SIM Elementary Files that are affected by the introduction of EONS feature in the SIM card:

EF

EF

SST

OPL

EF

PNN

(SIM Service Table) - describes which features are active.

(Operator PLMN List) - contains the PLMN identification and location ID together with the index of the corresponding PNN record.

(PLMN Network Name) - contains the full and short form version of the network name for the registered PLMN.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 40

Chapter 3 – Status Control Commands

“nitz“

EF

ONString

If the Operator Name Source is CPHS Operator Name String long and short form, refer to <indValue>, the following two SIM Elementary Files are used:

(Operator Name String) - contains the name of the PLMN operator who issued the SIM.

EF

OPShort

(Operator Name Short form) - contains a short form of the name of the

PLMN operator who issued the SIM.

Network Identity and Time Zone indication This indicator shows the time relevant information elements of an MM Information (MMI) or GMM Information (GMMI) message received from the network (see GSM 24.008, ch. 9.2.15a and 9.4.19). The network usually sends a NITZ indicator when the mobile attaches to the network, when it enters a location area with different time zone or when a daylight change occurs.

A NITZ indicator may consist of the following parameters: Universal Time (UT), local Time

Zone (TZ), Daylight Saving Time (DST). All information elements of MMI/GMMI are optional and, therefore, the presentation of the parameters <nitzUT>, <nitzTZ>, <nitzDST> varies with the network. For example, the network may send all three parameters UT, TZ, DST, or only UT and TZ or only TZ.

UT is indicated in usual date/time format and represents the current world time (GMT) at the moment when sent.

TZ is given as a positive (east) or negative (west) offset from UT in units of 15 minutes.

DST shows the number of hours added to the local TZ because of daylight saving time

(summertime) adjustment. Usually DST is 1 hour but it can be also 2 hours in certain locations.

Example for time and time zone with DST:

+CIEV: nitz,”04/07/23,13:39:20”,-28,1

In this example TZ is -28, showing a time offset of -7 hours (west) to Universal Time/GMT

(which never changes for DST). DST is 1 which indicates that one hour was added to TZ because of Daylight Saving Time. If a network does not send the DST parameter the TZ value would be -32 (8 hours west) as would be done in winter:

+CIEV: nitz,”04/11/23,13:39:20”,-32

Please be aware that despite the last NITZ value can be looked up again via “AT^SIND=nitz,2” the returned values may be out of date. Especially the UT value is obsolete because there is no internal NITZ clock and therefore no continuation of UT.

NITZ values are lost when the module detaches from network. Also when a manual network selection fails and the module automatically falls back to the previous network the NITZ values cannot be recalled. Nevertheless an indicated time zone is valid until a new MMI/GMMI will trigger another NITZ indication.

“simstatus“ SIM Status Indication

The SIM Status indicator allows the MC75 to output the status of the subscriber identity module (SIM) via URC.

0 SIM card removed.

1

2

3

4

Note: Another way to verify the SIM card connection is the “^SCKS”

URC enabled with AT^SCKS. For use after restart, its presentation mode can be stored to the user profile with AT&W.

SIM card inserted.

SIM PIN1 not required - SIM card unlocked. MC75 automatically registers to the

GSM network without requesting SIM PIN1.

SIM PIN1 required - SIM card locked. SIM PIN1 must be entered to enable MC75 to register to the GSM network.

Personalization info ready - CHV (Card Holder Verification) data has been verified (if required).

“band“ Currently selected frequency band or band combination.

1...14 Identical with <rbc> of AT^SCFG. The value indicates the band(s) currently available for network selection, depending on the network configuration either a single band or a dualband combination. The URC appears whenever the status of the currently available band(s) changes, for example after using the AT^SCFG command to change the “Radio/Band” parameters <rba> or <rbp>. Please see

AT^SCFG for further detail about the feature “Radio/Band” selection.

<indValue>

Integer type value in the range stated above for the corresponding <indDescr>.

Notes specific to the EONS feature:

If the indicator is “eons”, the <indValue> is a type associated to the operator name according to GSM 22.101

[23]. This type depends on the source of the operator name.

Priority of types associated to the operator names is defined as follows (the type listed first has the highest priority). If a type cannot be indicated the next one will be used.

0 Not registered.

1 EF-OPL and EF-PNN (alphanumeric format, can contain up to 24 characters.)

2 Operator Name String in long and short format according to Common PCN Handset Specification

(CPHS) (alphanumeric format, can contain up to 16 characters).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 41

Chapter 3 – Status Control Commands

3 Name information received by the NITZ service long and short form (alphanumeric format, can contain up to 16 characters). The short form will be displayed only if EF

OPShort

from CPHS is available.

4 Any operator name stored internal to the ME (alphanumeric format, can contain up to 16 characters).

5 Broadcast MCC-MNC (numeric format which consists of a 3-digit country code plus a 2- or 3-digit network code).

The name information received by the NITZ service (type 3) will be saved in the non-volatile RAM. It replaces the operator name of the registered PLMN (type 4) or its numeric form (type 5) stored in the ME. However, when after restart the ME registers to another PLMN that is not equal to the saved NITZ name information, the

NITZ name information must be invalidated.

If the type is 2, 4 or 5, AT+COPS with the appropriate <mode> displays the same operator name.

<mode>

0 Indicator is deregistered; i.e., no such indicator event report (URC) will be issued. <mode>=0 is power-up and factory default of indicators defined by AT^SIND only.

1 Indicator is registered.

• Indicator event reports are controlled via AT+CMER.

• All indicators can be registered or deregistered via AT^SIND, but different default settings apply:

Power-up and factory default of the indicators supported by AT+CIND is <mode>=1, while, as stated above, indicators defined by AT^SIND only are set to <mode>=0.

2 Query the registration status and the current value of a single indicator type.

<vmCounter>

If delivered by the network: Number of new voice messages sent as part of the Voice Message Waiting

Indicator. Refer to <indDescr>.

<eonsOperator>

Operator in format which depends on the type associated to the operator name. Refer to <indValue>.

<servProvider>

Service Provider Name according to the status settings (SIM Service No. 17) in the SIM Service Table (SST).

<nitzUT>

Universal Time delivered as part of the “nitz” Indicator. Refer to <indDescr>.

<nitzTZ>

Time Zone delivered as part of the “nitz” Indicator. Refer to <indDescr>.

<nitzDST>

Adjustment for Daylight Saving Time as part of the “nitz” Indicator. Refer to <indDescr>.

Example of Activation and use of indicator “audio”:

AT^SIND=”audio”,1

^SIND: audio,1,0

OK

AT+CMER=2,,,2

OK

You register the indicator “audio”.

You activate the Indicator Event Report with AT+CMER.

A set of all registered URCs is presented. (Please note that the example includes the indicators registered due to the power-up default settings of AT+CIND.)

+CIEV: battchg,5

+CIEV: signal,99

+CIEV: service,1

+CIEV: sounder,0

+CIEV: message,1

+CIEV: call,0

+CIEV: roam,0

+CIEV: smsfull,0

+CIEV: rssi,4

+CIEV: audio,0

ATD030123456

OK

+CIEV: audio,1

+CIEV: sounder,1

+CIEV: call,1

+CIEV: signal,0

+CIEV: sounder,0

ATH

OK

+CIEV: call,0

+CIEV: rssi,3

+CIEV: audio,0

+CIEV: signal,99

+CIEV: rssi,4

You make a call.

You hang up.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 42

Chapter 3 – Status Control Commands

3.4 AT+CEER Extended Error Report

Description: AT+CEER returns an extended error report regarding the reason of the last

• call release

• failure to set up a call (both mobile originated or terminated)

• failure to modify a call by using Supplementary Services

• failed attempt to activate, register, query, deactivate or deregister a Supplementary Service

• unsuccessful GPRS attach or unsuccessful PDP context activation

• GPRS detach or PDP context deactivation

The release cause report is presented in numeric format. Default output in case of a none-errorsituation is +CEER: 0,0,0. A description associated with each number can be found in the tables given in the following subclauses and the relevant GSM specifications.

The first parameter <locationID> serves to locate the other two parameters. Depending on the failure or release cause either <reason> or <ssRelease> are applicable; i.e., if <reason> ≠ 0, then <ssRelease> = 0.

Vice versa, if <reason> = 0, then <ssRelease> may be ≠ 0.

AT+CEER is not available for data calls, please use ATS18=1 instead.

Exe. Command Syntax: AT+CEER

Exe. Response: +CEER: <locationID>, <reason>, <ssRelease>

OK

ERROR

ERROR

Test Command Syntax: AT+CEER=?

Test Response: OK

ERROR

+CME

Parameter Description:

<locationID>

Location ID as number code. Location IDs are listed in Section 3.4.1, Cause Location ID for the extended error report. Each ID is related with another table that contains a list of <reason>s or <ssRelease>s.

<reason>

Reason for last call release as number code. The number codes are listed in several tables, sorted by different categories in the following subclauses. The tables can be found proceeding from the Location ID given in

Section 3.4.1, Cause Location ID for the extended error report.

<ssRelease>

Release cause for last Supplementary Service call (listed in Section 3.4.5, GSM Release cause for

Supplementary Service Call) or last call related use of a Supplementary Service (listed in Section 3.4.10,

Release cause for Call-related Supplementary Services (CRSS)).

Examples:

Example 1

ATD”01751223344”;

NO CARRIER

AT+CEER

+CEER: 8,21,0

OK

Example 2

The user attempts to set up a multiparty call, though there are only two parties involved in the present conversation:

ATD”01751223344”;

OK

AT+CHLD=2

OK

AT+CHLD=3

+CME ERROR:

AT+CEER

+CEER: 22,0,2 The

A mobile originated call is rejected by the remote party.

Call setup is terminated with NO CARRIER.

To check the cause, the caller enters AT+CEER.

The Location ID 8 in Section 3.4.1 points to Section 3.4.4, where 21 =

“Call rejected”. 0 = “No error” refers to parameter <ssRelease> that is not applicable. operation temporary not allowed

Location ID 22 in Section 3.4.1 points to release cause for Call-Related Supplementary

Services (CRSS), where 2 = “Initial conditions not fulfilled (one active, one held call)”. 0 =

“No error” refers to parameter <reason> that is not applicable.

Example 3

The user attempts to activate call barring. Activation is denied by the network since the password is blocked after previous failures to enter the password.

AT+clck=oi,1,”0000”,3;

+CME ERROR:

AT+CEER

+CEER: 35,0,43

OK incorrect password

The Location ID 35 in Section 3.4.1 points to Section 3.4.5, where 43 =

“NumberOfPWAttemptsViolation” may mean that a wrong password has been entered for more than 3 times. 0 = “No error” refers to parameter <reason> that is not applicable.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 43

Chapter 3 – Status Control Commands

3.4.1 Cause Location ID for the Extended Error Report

ID Description

0

2

4

8

No error (default)

GSM cause for L3 Radio Resource Sublayer (GSM 04.08 annex F)

GSM cause for L3 Mobility Management (GSM 04.08 annex G)

GSM cause for L3 Call Control (GSM 04.08 10.5.4.11 and annex H)

12 GSM cause for L3 SMS CP Entity

14 GSM cause for L3 SMS RL Entity

16 GSM cause for L3 SMS TL Entity

21 GSM cause for L3 Call-related Supplementary Services

34 Network cause for Supplementary Services (GSM 04.08 10.5.4.11 and annex H)

35 Supplementary Services network error (GSM 04.803.6.6)

48 GSM cause for GPRS Mobility Management (GSM 04.08 annex G.6)

50 GSM cause for Session Management (GSM 04.08 annex I)

128 Supplementary Services general problem (GSM 04.80 3.6.7)

129 Supplementary Services invoke problem (GSM 04.80 3.6.7)

130 Supplementary Services result problem (GSM 04.80 3.6.7)

131 Supplementary Services error problem (GSM 04.80 3.6.7)

241 Cause for GPRS API

242 Cause for Link Management

243 Cause for PPP/IP-Stack

3.4.2 GSM Release Cause for L3 Radio Resource (RR)

Number/Description

0

1

2

3

4

Normal event

Abnormal release, unspecified

Abnormal release, channel unacceptable

Abnormal release, timer expired

Abnormal release, no activity on the radio path

Pre-emptive release 5

8

9

Handover impossible, timing advance out of range

Channel mode unacceptable

10 Frequency not implemented

65 Call already cleared

95 Semantically incorrect message

96 Invalid mandatory information

97 Message type non-existent or not implemented

98 Message type not compatible with protocol state

100 Conditional information element error

101 No cell allocation available

111 Protocol error unspecified

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 44

Chapter 3 – Status Control Commands

3.4.3 GSM Release Cause for Mobility Management (MM)

Number/Description

Causes related to MS identification

2

3

4

5

IMSI unknown in HLR

Illegal MS

IMSI unknown in VLR

IMEI not accepted

6 Illegal ME

Cause related to subscription options

11 PLMN not allowed

12 Location Area not allowed

13 Roaming not allowed in this location area

Causes related to PLMN specific network failures and congestion

17 Network failure

22 Congestion

Causes related to nature of request

32 Service option not supported

33 Requested service option not subscribed

34 Service option temporarily out of order

38 Call cannot be identified

Causes related to invalid messages

95 Semantically incorrect message

96 Invalid mandatory information

97 Message type non-existent or not implemented

98 Message not compatible with protocol state

99 Information element non-existent or not implemented

100 Conditional information element error

101 Messages not compatible with protocol state

111 Protocol error, unspecified

Causes related GPRS

7

8

9

GPRS services not allowed

GPRS services not allowed in combination with non-GPRS services

MS identity cannot be identified by the network

10 Implicitly detached

14 GPRS services not allowed in current PLMN

16 MSC temporarily unreachable

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 45

3.4.4 GSM Release Cause for L3 Call Control (CC)

Number/Description

0 No error

Normal class

1 Unassigned (unallocated) number

3 No route to destination

6 Channel unacceptable

8 Operator determined barring

16 Normal call clearing

17 User busy

18 No user responding

19 User alerting, no answer rejected

22 Number

25 Pre-emption

26 Non-selected user clearing

27 Destination out of order

28 Invalid number format (incomplete number)

29 Facility rejected

30 Response to STATUS ENQUIRY

31 Normal, unspecified

Resource unavailable class

34 No circuit/channel available

38 Network out of order

41 Temporary failure

42 Switching equipment congestion

43 Access information discarded

44 Requested circuit/channel not available

47 Resource unavailable, unspecified

Service or option not available class

49 Quality of service unavailable

50 Requested facility not subscribed

55 Incoming calls barred within the CUG

57 Bearer capability not authorized

58 Bearer capability not presently available

63 Service or option not available, unspecified

Service or option not implemented

65 Bearer service not implemented

68 ACM equal or greater than ACMmax

69 Requested facility not implemented

70 Only restricted digital information bearer capability is available

79 Service or option not implemented, unspecified

Invalid message (e.g., parameter out of range) class

81 Invalid transaction identifier value

87 User not member of CUG

88 Incompatible destination

91 Invalid transit network selection

95 Semantically incorrect message

Protocol error (e.g., unknown message) class

96 Invalid mandatory information

97 Message type non-existant or not implemented

98 Message type not comaptible with protocol state

99 Information element non-existent or not implemented

100 Conditional information element error

101 Message not compatible with protocol

102 Recovery on timer expiry

111 Protocol error, unspecified

Interworking class

127 Interworking, unspecified

Chapter 3 – Status Control Commands

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 46

Chapter 3 – Status Control Commands

3.4.5 GSM Release Cause for Supplementary Service Call

Number/Description

0

1

9

No error (default)

UnknownSubscriber

IllegalSubscriber

10 BearerServiceNotProvisioned

11 TeleserviceNotProvisioned

12 IllegalEquipment

13 CallBarred

15 CUGReject

16 IllegalSSOperation

17 SSErrorStatus

18 SSNotAvailable

19 SSSubscriptionViolation

20 SSIncompatibility

21 FacilityNotSupported

27 AbsentSubscriber

29 ShortTermDenial

30 LongTermDenial

34 SystemFailure

35 DataMissing

36 UnexpectedDataValue

37 PWRegistrationFailure

38 NegativePWCheck

43 NumberOfPWAttemptsViolation

71 UnknownAlphabet

72 USSDBusy

126 MaxNumsOfMPTYCallsExceeded

127 ResourcesNotAvailable

General Problem Codes

300 Unrecognized Component

301 Mistyped Component

302 Badly Structured Component

Invoke Problem Codes

303 Duplicate Invoke ID

304 Unrecognized Operation

305 Mistyped Parameter

306 Resource Limitation

307 Initiating Release

308 Unrecognized Linked ID

309 Linked Response Unexpected

310 Unexpected Linked Operation

Return Result Problem Codes

311 Unrecognize Invoke ID

312 Return Result Unexpected

313 Mistyped Parameter

Return Error Problem Codes

314 Unrecognized Invoke ID

315 Return Error Unexpected

316 Unrecognized Error

317 Unexpected Error

318 Mistyped Parameter

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 47

Chapter 3 – Status Control Commands

3.4.6 GSM Cause for L3 Protocol Module or Other Local Cause

Number/Description

2 No detailed cause

3.4.7 Release Cause for GPRS API

Number/Description

0 Regular deactivation of the call

1

2

3

4

Action temporarily not allowed

Wrong connection type

Specified data service profile invalid

PDP type or address is unknown

5 FDN Check was not successful; GPRS Attach and PDP Context Activation blocked

255 Undefined

3.4.8 Release Cause for PPP/IP-Stack

Number/Description

0

1

Regular call deactivation

LCP stopped

255 Undefined

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 48

Chapter 3 – Status Control Commands

3.5 ATS18 Extended Call Release Report

Description: ATS18 controls the presentation of extended call release reports for circuit switched fax and data calls. Extended call release reports related to voice calls are controlled via AT+CEER.

The call release report is presented in numeric format and shows as follows:

<locationID>:<reason>

If enabled the message will be reported every time a fax or data call is released or fails to be established.

Read Command Syntax: ATS18?

Read Response: <n>

OK

Write Command Syntax: ATS18=<n>

Write Response: OK

ERROR

Parameter Descriptions:

<n>

An odd number enables the presentation of the extended call release report. Any even number disables this feature. This parameter can be stored with the the AT&W command. It can be displayed with the AT&V command. The default is 0.

0...255

<locationID>

Location ID as number code, see also <locationID> of AT+CEER.

Location IDs are listed in Section 3.4.1, Cause Location ID for the extended error report. Each ID is related to another table that contains a list of <reason>s.

<reason>

Reason for last call release as number code (see also <reason> of AT+CEER).

<reason> numbers and the associated descriptions are listed in several tables, sorted by different categories at

AT+CEER. The tables can be found proceeding from the Location IDs listed in Section 3.4.1, Cause Location ID for the extended error report.

Examples

Example 1

ATS18=1

OK

ATD03012345678

+CAUSE: 8:17

BUSY

Enables the presentation of extended call release reports.

Now, a mobile originated data call fails.

An extended error report is output, followed by the result code BUSY.

The Location ID 8 stated in Section 3.4.1 points to Section 3.4.4, with 17 = “User busy”.

Example 2

ATS18=1

OK

ATD03012345678

CONNECT 9600/RLP

Hello,....

+++

+CAUSE: 8:16

NO CARRIER

Enables the presentation of extended call release reports.

Now, a mobile originated data call is set up.

Call ends after remote party hung up.

Normal call release is reported, followed by the result code NO CARRIER.

The Location ID 8 stated in Section 3.4.1 points to Section 3.4.4, with 16 = “Normal call clearing”.

3.6 AT+CPAS Mobile Equipment Activity Status

Description: The AT+CPAS execute command indicates the activity status of the ME.

Test CommandSyntax : AT+CPAS=?

Test Response: +CPAS: (list of supported<pas>s)

OK

Exec Command:

Response:

OK

Parameter Description

<pas>

AT+CPAS

+CPAS: <pas>

0 Ready

3 Incoming call (ringing)

4 Call in progress or call hold

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 49

Chapter 3 – Status Control Commands

3.7 AT+WS46 Select Wireless Network

Test Command Syntax: AT+WS46=?

Test Response: +WS46: (list of supported<n>s)

OK

Read Command Syntax: AT+WS46?

Read Response: <n>

OK

Write Command Syntax: AT+WS46=[<n>]

Write Response: OK

ERROR

+CME

Parameter Description

<n>

12 GSM digital cellular

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 50

Chapter 4 – Serial Interface Control Commands

Chapter 4. Serial Interface Control

Commands

The AT Commands described in this chapter allow the external application to determine various settings related to the Multi-Tech wireless modem’s serial interface.

4.1 AT\Q Flow Control

Exec Command Syntax: AT\Q[<n>]

Response: OK

If RTS/CTS flow control is not supported by interface and <n> is 2 or 3:

ERROR

Parameter Description:

<n>

0 Disable flow control. Default.

1 XON/XOFF software flow control

2 Only CTS by DCE (TA)

3 RTS/CTS hardware flow control

Recommended for the following procedures: incoming or outgoing data calls, fax calls, MUX mode.

Often, the initialization routine of Fax programs includes enabling RTS/CTS handshake, eliminating the need to issue AT\Q3 once again.

Notes:

• When using XON/XOFF flow control (AT\Q1) in online mode, +++ should not be used while the data transmission is paused with XOFF. Before entering the command mode with +++ the paused transmission should be resumed using the XON character.

• Flow Control can be set by also using AT+IFC.

4.2 AT&C Set Circuit Data Carrier Detect (DCD)

Function Mode

Description: The AT&C command determines how the state of circuit 109 (DCD) relates to the detection of received line signal from the distant end.

Exec Command Syntax: AT&C[value]

Response: OK

Parameter Description:

<value>

0 DCD line is always ON. Default.

1 DCD line is ON in the presence of data carrier only.

4.3 AT&D Set Circuit Data Terminal Ready (DTR)

Function Mode

Description: The AT&D determines how the TA responds when circuit 108/2 (DTR) is changed from

ON to OFF during data mode.

Exec Command Syntax: AT&D[<value>]

Response: OK

Parameter Description:

<value>

0 TA ignores status of DTR. Default.

1 ON->OFF on DTR: Change to command mode while retaining the connected call.

2 ON->OFF on DTR: Disconnect data call, change to command mode. During state DTR = OFF auto-answer is off.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 51

Chapter 4 – Serial Interface Control Commands

4.4 AT&S Set Circuit DSR Function Mode

Description: The

Exec Command:

Response: depending on the communication state of the TA interfacing TE.

AT&S<value>

OK

Parameter Description:

<value>

0

1

DSR line is always ON. Default.

TA in command mode: DSR is OFF.

TA in data mode: DSR is ON.

4.5 ATE Enable Command Echo

Description:

Exec Command:

The ATE command determines whether or not the TA echoes characters received from

TE during command state.

ATE[<value>]

Response:

Parameter Description:

<value>

0

1

OK

Echo mode off. Default.

Echo mode on

Note: In case of using the command without parameter, <value> is set to 0.

4.6 AT+ICF Serial Interface Character Framing

Description: The command AT+ICF controls the serial interface character framing format and parity used for receiving and transmitting. The following settings are supported:

• 7 bits, even parity, 1 stop bit (AT+ICF=5,1)

• 7 bits, odd parity, 1 stop bit (AT+ICF=5,0)

• 8 bits, even parity, 1 stop bit (AT+ICF=2,1)

• 8 bits, no parity, 1 stop bit (AT+ICF=3)

• 8 bits, odd parity, 1 stop bit (AT+ICF=2,0)

• 8 bits, no parity, 2 stop bits (AT+ICF=1)

Test Command Syntax: AT+ICF=?

Response(s): +ICF: (list of supported <format>s), (list of supported <parity>s)

OK

Read Command Syntax: AT+ICF?

Response(s): +ICF: <format>[, <parity>]

OK

Write Command Syntax: AT+ICF=[<format>][, <parity>]

Response(s): OK

ERROR

Parameter Descriptions:

<format>

Specifies the character format used for receiving and transmitting.

1

2

8 data 0 parity 2 stop

8 data 1 parity 1 stop

3

5

8 data 0 parity 1 stop

7 data 1 parity 1 stop

<parity>

Specifies the method of calculating the parity bit, if a parity bit is supported by <format>.

If <format> does not support parity, this parameter has to be omitted.

0 odd even 1

Notes:

• If AT+ICF modes 7E1 or 7O1 are set, the parity bit will by default not be transmitted over the air. If the remote party expects the parity bit to be transmitted, additional settings are required via AT^STPB.

• When using a bit rate of 300 bps there must be a delay of 500ms before entering the next command. At bit rates of 1200 bps the delay must be 300ms. For higher bit rates use of the default delay is sufficient.

• The Multi-Tech wireless modem’s autobaud feature detects the bit rate currently used by the TE. However, this detection suffers some limitations described in Section 4.9.1, Autobauding. If autobauding is enabled, the

AT+ICF read command does not show the current character framing, but the character framing that will be used when autobauding is disabled.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 52

Chapter 4 – Serial Interface Control Commands

• For compatibility reasons, the command can be used in Multiplex mode, though the settings will not take effect. Please note that changes made on multiplex channel 1 will be saved with AT&W and will become active when restarting the ME after AT^SMSO.

• To start the multiplexer it is necessary to set the character framing to 8 bits, no parity and 1 stop bit.

• If a <format> is selected without parity (e.g. <format>=3) and you try to activate a format with parity (e.g.,

<format>=2), you need to explixitly set the parameter <parity> (e.g. AT+ICF=2,1). Otherwise you will get

‘+CME ERROR: invalid index’. This is because for <format>=3, the parameter <parity> is set to the internal value ‘no parity’ which is not supported by <format>=2. (Remember that if an optional parameter is omitted for which no default is stated in this specification, the value of the parameter remains unchanged).

4.7 AT+IFC Set Flow Control Separately for Data

Directions

Description: The command AT+IFC can be used to set or query the data flow control separately for each data direction. In contrast to this, flow control settings made with AT\Q are valid in both data directions.

Test Command Syntax: AT+IFC=?

Response(s): +IFC: (list of supported <TEflowcontrol>s), (list of supported <TAflowcontrol>s)

OK

Read Command Syntax: AT+IFC?

Response(s): +IFC: <TEflowcontrol>, <TAflowcontrol>

OK

Write Command Syntax: AT+IFC=<TEflowcontrol>, <TAflowcontrol>

Response(s): OK

ERROR

Parameter Descriptions:

<TEflowcontrol>

Specifies the method used by the TE when receiving data from the TA.

0

1

2

3 none

XON/XOFF, terminate flow control in the Cellular Engine

RTS line

XON/XOFF, evaluate flow control in the Cellular Engine and pass it through (over the air) to the opposite TE

<TAflowcontrol>

Specifies the method used by the TA when receiving data from the TE.

0

1

2 none

XON/XOFF

CTS line

Notes:

• When using XON/XOFF flow control (AT+IFC=1,x or AT+IFC=3,x) in data mode, +++ should not be used while the data transmission is paused with XOFF. Before entering the command mode with +++ the paused transmission should be resumed using the XON character.

• For compatibility reasons, the AT+IFC command can be used in Multiplex mode, though the settings will not take effect. However, be aware that whenever you use the AT+IFC write command in Multiplex mode and then save the current configuration to the user profile with AT&W, the changed AT+IFC setting will become active after restart.

4.8 AT+ILRR Set TE-TA Local Rate Reporting

Description: The command AT+ILRR controls whether or not the intermediate result code “+ILRR” is transmitted from the TA to the TE while a connection is being set up. The result code indicates the local rate. It is issued before the final result code of the connection; e.g., CONNECT is transmitted to the TE.

Test Command Syntax: AT+ILRR=?

Response: +ILRR: (list of supported <value>s)

OK

Read Command Syntax: AT+ILRR?

Response: +ILRR: <value>

OK

Write Command Syntax: AT+ILRR=<value>

Response: OK

ERROR

Intermediate Result Code: +ILRR: <rate>

Indicates local port rate setting upon connection setup.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 53

Chapter 4 – Serial Interface Control Commands

Parameter Descriptions:

<value>

0 Disables reporting of local port rate

1 Enables reporting of local port rate

<rate>

Port rate setting upon connection setup (bps)

0 Autobauding (see Section 4.9.1, Autobauding).

300

600

1200

2400

4800

9600

14400

19200

28800

38400

57600

115200

230400

460800

4.9 AT+IPR Set Fixed Local Rate

Description: The command AT+IPR can be used to set or query the TE-TA interface bit rate.

The test command returns the values of the supported automatically detectable bit rates and the values of the supported fixed bit rates.

The read command returns the current bit rate of the interface.

The write command specifies the bit rate to be used for the interface. When you set a fixed-rate, make sure that both TE (DTE) and TA (DCE) are configured to the same rate. When you select autobauding, the TA will automatically recognize the bit rate currently used by the TE.

The setting is stored in the non-volatile memory and will be used whenever the engine is powered up again. However, in case of autobaud mode (AT+IPR=0) the detected TA bit rate will not be saved and, therefore, needs to be resynchronized after restarting the GSM engine (see

Section 4.91, Autobauding).

Test Command Syntax: AT+IPR=?

Response: +IPR: (list of supported auto-detectable <rate>s) , (list of supported fixed-only <rate>s)

OK

Read Command Syntax: AT+IPR?

Response: +IPR: <rate>

OK

Write Command Syntax: AT+IPR=<rate>

Response: OK

ERROR

ERROR

Parameter DescriptionsD

<rate> bit rate per second (bps)

0 Default. Activates autobauding. See Section 4.91, Autobauding for further details.

300

600

1200

2400

4800

9600

14400

19200

28800

38400

57600

115200

230400

460800

Notes:

• Factory default is autobauding enabled (AT+IPR=0). It will not be restored with AT&F.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 54

Chapter 4 – Serial Interface Control Commands

• The current setting of AT+IPR will be preserved when you download firmware or in the event of power failure.

Note: A firmware update does not restore the factory setting.

• Generally, AT+IPR should be used as a standalone command. If nethertheless combinations with other commands on the same command line cannot be avoided, there are several constraints to be considered:

∗ Avoid combinations with the AT commands listed in Section 1.4.2, Combining AT commands on the same command line.

∗ Take into account, that a delay of 100ms is required between the response to the last command (e.g., OK) and the next command on the same line.

∗ When you enter AT+IPR=0, autobauding will be activated after the response to the last command is received.

∗ When local echo is active (ATE1) and you enter AT+IPR=x with other commands you may encounter the following problem: if switching to the new bit rate takes effect while a response is being transmitted, the last bytes may be sent with the new bit rate and thus, not properly transmitted. The following commands will be correctly sent at the new bit rate.

• In order to account for greater amounts of data it is recommended to choose a minimum bit rate of 2400 bps. If the ME is operated in Multiplex mode we suggest a minimum bit rate of 4800bps.

• A selected bit rate takes effect after the write commands returns OK (except for Multiplex mode).

• In Multiplex mode, the write command AT+IPR=<rate> will not change the bit rate currently used, but the new bit rate will be stored and becomes active, when the module is restarted.

4.9.1 Autobauding

To take advantage of autobaud mode specific attention must be paid to the following requirements:

• Synchronization between TE and TA.

Ensure that TE and TA are correctly synchronized and the bit rate used by the TE is detected by the TA. To allow the bit rate to be synchronized simply use an “AT” or “at” string. This is necessary

∗ after you have activated autobauding

∗ when you start up the GSM engine while autobauding is enabled. It is recommended to wait 3 to 5 seconds before sending the first AT character. Otherwise undefined characters might be returned.

If you want to use autobauding and autoanswer at the same time, you can easily enable the TE-TA synchronization, when you activate autobauding first and then configure the autoanswer mode (ATS0 ≠’ 0).

• Restrictions on autobauding operation.

∗ The serial interface shall be used with 8 data bits, no parity and 1 stop bit (factory setting); e.g., 2 stop bits are not supported for autobaud mode.

∗ The command A/ cannot be used.

∗ Only the strings “AT” or “at” can be detected (neither “At” nor “aT”).

∗ URCs that may be issued before the ME detects a new bit rate (by receiving the first AT character) will be sent at the previously detected bit rate or, after ME restart, at 57600 bps.

∗ It is not recommended to switch to autobauding from a bit rate that cannot be detected by the the autobaud mechanism (e.g., 300 bps). Responses to AT+IPR=0 and any commands on the same line might be corrupted.

∗ When autobauding is switched on: (DAR)

∗ only data length, parity, and baud rate are automatically detected.

∗ if using 1 stop bit, AT+ICF=1 should not be used because AT+ICF=1 uses 2 stop bits.

∗ if using 2 stop bits, no combination of AT_ICF should be used.

• Autobauding and bit rate after restart.

The most recently detected bit rate is stored when the ME is powered down (with AT^SMSO). Therefore, each time the module is restarted the correct bit rate must be found as described above. Unless the bit rate is determined, the following constraints apply:

∗ An incoming CSD call or a network initiated GPRS request cannot be accepted. This must be taken into account when autobauding and autoanswer mode (ATS0 ≠’ 0) are enabled at the same time, especially if SIM

PIN 1 authentication is done automatically and the setting ATS0 ≠’ 0 is stored to the user profile with AT&W.

Until the bit rate is found, URCs generated after restart will be output at 57600 bps. This applies only to user defined URCs, such as “+CREG”, “CCWA”, “^SCKS” etc. The URCs “^SYSSTART”, and "^SYSSTART

AIRPLANE MODE" will not be indicated when autobauding is enabled.

Note: To avoid any problems caused by undetermined bit rates in the direction from TA to TE we strongly recommend to configure a fixed bit rate rather than autobauding.

• Autobauding and multiplex mode.

If autobauding is active, you cannot switch to multiplex mode.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 55

Chapter 4 – Serial Interface Control Commands

4.10 AT+CMUX Enter Multiplex Mode

Description: All information provided in this section applies to the ASC0 interface only.

Multiplex mode according to the ETSI TS 101 669 and GSM 07.10 enables one physical serial asynchronous interface to be partitioned into three virtual channels. This allows you to take advantage of up to 3 simultaneous sessions running on the serial interface. For example, you can send or receive data or make a call on the first channel, while the other two channels are free to control the module with AT commands.

The Multi-Tech wireless modem module incorporates an internal multiplexer and thus integrates all the functions needed to implement full-featured multiplex solutions. For the application on top, customers have the flexibility to create their own multiplex programs conforming to the multiplexer protocol. To help system integrators save the time and expense of designing multiplexer applications, contact Multi-Tech about a ready-to-use multiplex driver for Windows

2000 and Windows XP. Another approach is to develop customized solutions based on the sources of the WinMux2k driver.

The WinMUX2k driver and its source files can be supplied on request. Please contact your local distributor to obtain the latest installation software and user’s guide.

Test Command Syntax AT+CMUX=?

Response: +CMUX: (list of supported<mode>s)

OK

Read Command Syntax: AT+CMUX?

Response: +CMUX: <mode>

OK

ERROR

+CME ERROR: <err>

Write Command Synatx: AT+CMUX=<mode>

Response: OK

ERROR

Parameter Descriptions:

<mode>

+CME ERROR: <err>

Multiplexer transparency mechanism

0 Basic option

<subset>

Subparameters defined in GSM07.07 are adjusted for control and logical channels as follows 0 UIH frames used only (control channel)

Notes:

• The write command is used to enter the multiplex mode. The setup of the logical channels is initiated by the TE; i.e., the TE acts as initiator. This means that the TE shall ensure that logical channels are established before any further actions on the channels can be started.

• There is a timeout of five seconds, if the multiplexer protocol is enabled and no multiplexer control channel is established. The GSM engine returns to AT command mode.

• The parameter maximum frame size (N1) of AT+CMUX in GSM 07.10 is fixed to 98 bytes and cannot be changed. All other parameters are not available.

• Multiplexer mode requires character framing to be set to 8 bits, no parity, and 1 stop bit. The settings can be using AT+ICF=3.

4.10.1 Restrictions on Multiplex Mode

When the serial interface ASC0 is in multiplex mode, data and fax calls can only be set up on logical channel 1.

Due to this restriction, AT commands have a different behavior on channels 2+3 compared to channel 1. Several commands are not available, others return different responses. This section summarizes the concerned commands.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 56

Chapter 4 – Serial Interface Control Commands

Table 4.1 – Availability of AT Commands on Virtual Channels

Command

+++

AT+CBST

AT+CRLP

Behavior on Channel 1 Behavior on Channel 2=3 not usable, but see note 2) not usable, but see note 2 as described as described not usable not usable

AT+CG... (GPRS commands) as described

AT+F... (Fax commands) as described

AT&S

ATA as described as described see note 3. not usable not usable no Data Calls

ATD

ATDI

ATL

ATM

ATO

ATS6 See Note 1

ATS7 See Note 1

ATS8 See Note 1

ATS10 See Note 1

ATS18 See Note 1 as described as described as described as described as described as described as described as described no Data Calls not usable not usable not usable not usable not usable not usable not usable

Notes:

1. GSM engines support the registers S0 - S29. You can change S0,S3,S4,S5,S6,S7,S8,S10 and S18 using the related ATSn commands (see starting from ATS0). The other registers are read-only and for internal use only!

2. The applicability of the +++ escape sequence depends on the customer’s external application based on the

Mulitplexer Protocol. Recommendations for implementing an appropriate modem status command (MSC) are provided in [5], Section “Escape Sequence”.

3. PDP contexts can be defined on any channel, but are visible and usable only on the channel on which they are defined (thus, it is not possible to define a context on channel 2 and activate it on channel 3). GPRS connections can be established on two channels at a time.

Table 4.2 – Summary of AT Commands with Different Behavior in Multiplex Mode

Command

AT\Q

AT&V

AT+IPR

AT+IPR=0

AT+CALA

AT+CMEE

AT+CNMA

AT+CNMI

AT+CFUN

AT+CPMS

AT^SSDA

Description

It is recommended to use hardware flow control (AT\Q3). XON/XOFF flow control

(AT\Q1) is not supported in Multiplex mode.

See note regarding AT\Qn settings stored with AT&W if Multiplex mode is active.

Different default configurations on channels 1, 2 and 3. user can be stored on each channel.

Before you start Multiplex mode, it is recommended to set the ME to 57600 bps

(minimum should be 4800 bps). For GPRS we suggest to use 115200 bps or 230400 bps.

In Multiplex mode, the write command AT+IPR=<rate> will not change the bit rate currently used, but the new bit rate will be stored and becomes active, when the module is restarted.

Multiplex mode cannot be activated while autobauding is enabled.

On each channel an individual <text> message can be stored. but only one time setting applies to all channels. This means an alarm <time> set on one of the channels overwrites the time setting on all remaining channels. Therefore, the total number of alarm events returned by the read command AT+CALA? will always be <n>=0, no matter whether individual text messages are stored.

When the alarm is timed out and executed the ME sends the URC only on the channel where the most recent alarm setting was made. The alarm time will be reset to “00/01/01,00:00:00” on all channels.

Presentation mode can be separately configured for each channel.

If Multiplex mode is activated the +CNMI parameter will be set to zero on all channels, if one channel fails to acknowledge an incoming message within the required time.

Phase 2+ parameters can only be used on one channel. The parameter for <mt> and <ds> on the other channels have to be set to zero. If either a SM or a Status Report is not acknowledged, all

+CNMI parameter will be set to zero on all channels.

If the ME is in Multiplexer mode, it is not recommended to activate SLEEP mode with

AT+CFUN=<fun>. The best approach to properly control SLEEP mode in this case is to issue the

PSC messages described in [5], Section “Power saving control (PSC)”.

Parameter <mem3> will be the same on all instances, but the settings of <mem1> and <mem2> may vary on each instance.

If one instance is set to <da>=1 and <mt>=1, then all other instances must be configured for

<mt>=0.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 57

Chapter 4 – Serial Interface Control Commands

4.11 AT+STPB Transmit Parity Bit (for 7E1 & 7O1

Only)

Description: This command is intended for use with 7E1 and 7O1 only. In addition to the 7E1 or 7O1 settings made with AT+ICF the command AT^STPB specifies whether or not to transmit the parity bit over the air.

Command Descriptions:

The test command returns the supported values of the parameter <n>.

The read command returns the current value of the parameter <n>.

The write command can be used to control the handling of the parity bit. If command fails,

“+CME ERROR: unknown” will be returned.

Test Command Syntax: AT^STPB=?

Response(s): ^STPB: (list of supported <n>s)

OK

Read Command Syntax: AT^STPB?

Response(s): ^STPB: <n>

OK

Write Command Syntax: AT^STPB=<n>

Response(s): OK

ERROR

+CME ERROR: unknown

Parameter Descriptions:

<n>

0

1

The parity bit will not be transmitted over the air and will be replaced with 0.

This mode is the default setting if 7E1 or 7O1 is activated with AT+ICF.

In a data connection 8 bits will be transmitted, including the parity bit; i.e., the parity bit will be properly transmitted over the air. The setting shall be used if problems are encountered when Multi-Tech wireless modem is running in the default 7E1 or 7O1 mode enabled with

AT+ICF. In this case, AT^STPB=1 shall be set in addition to the 7E1 or 7O1 settings selected with AT+ICF.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 58

Chapter 4 – Serial Interface Control Commands

Chapter 5. Security Commands

The AT Commands described in this chapter allow the external application to determine various security related settings.

5.1 AT+CPIN PIN Authentication

Description: AT+CPIN controls network authentication of the Multi-Tech wireless modem.

The read command returns an alphanumeric string indicating whether or not network authentication is required.

The write command allows the Multi-Tech wireless modem to store the entered password. This may be for example the SIM PIN1 to register to the GSM network, or the SIM PUK1 to replace a disabled SIM PIN1 with a new one, or the PH-SIM PIN if the client has taken precautions for preventing damage in the event of loss or theft etc.

If no PIN1 request is pending (for example if PIN1 authentication has been done and the same

PIN1 is entered again), the Multi-Tech wireless modem responds “+CME ERROR: operation not allowed”; no further action is required.

Test Command Syntax: AT+CPIN=?

Response: OK

Read Command Syntax: AT+CPIN?

Response: +CPIN: <code>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CPIN= < pin>[, <new pin>]

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<pin>

Password (string type), usually SIM PIN1.

If the requested password was a PUK, such as SIM PUK1 or PH-FSIM PUK or another password, then <pin> must be followed by <new pin>.

<new pin>

If the requested code was a PUK: specify a new password or restore the former disabled password. See Section

5.1.1, What to do if PIN or password authentication fails? for more information about when you may need to enter the PUK.

<code>

SIM PIN authentication

READY

SIM PIN

PIN has already been entered. No further entry needed.

ME is waiting for SIM PIN1.

SIM PUK

SIM PIN2

SIM PUK2

ME is waiting for SIM PUK1 if PIN1 was disabled after three failed attempts to enter PIN1.

ME is waiting for PIN2. This is only applicable when an attempt to access a PIN2 related feature was acknowledged with +CME ERROR: 17 (“SIM PIN2 required”), for example when the client attempts to edit the FD phonebook). In this case the read command AT+CPIN? also prompts for SIM PIN2. Normally, the AT+CPIN2 command is intended for SIM PIN2.

ME is waiting for PUK2 to unblock a disabled PIN2. As above, this is only necessary when the preceding command was acknowledged with +CME ERROR:

18 (“SIM PUK2 required”) and only if the read command AT+CPIN? also prompts for SIM

PUK2. Normally, the AT+CPIN2 command is intended for SIM PUK2.

Phone security locks set by client or factory

PH-SIM PIN ME is waiting for phone-to-SIM card password if “PS” lock is active and the client inserts other

SIM card than the one used for the lock. (“PS” lock is also referred to as phone or antitheft lock).

PH-SIM PUK ME is waiting for Master Phone Code, if the above “PS” lock password was incorrectly entered three times.

PH-FSIM PIN ME is waiting for phone-to-very-first-SIM card. Necessary when “PF” lock was set. When powered up the first time, ME locks itself to the first SIM card put into the card holder. As a result, operation of the mobile is restricted to this one SIM card (unless the PH-FSIM PUK is used as described below).

PH-FSIM PUK ME is waiting for phone-to-very-first-SIM card unblocking password to be given. Necessary when “PF” lock is active and other than first SIM card is inserted.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 59

Chapter 4 – Serial Interface Control Commands

PH-NET PUK ME is waiting for network personalization unblocking password.

PH-NS PIN

PH-NS PUK

PH-SP PIN

PH-SP PUK

PH-C PIN

ME is waiting for network subset personalization password.

ME is waiting for network subset unblocking password.

ME is waiting for service provider personalization password.

ME is waiting for service provider personalization unblocking password.

ME is waiting for corporate personalization password.

ME is waiting for corporate personalization un-blocking password. PH-C PUK

Notes:

Caution: After entering a password with AT+CPIN all other commands that need access to data on the SIM card may be blocked for up to 20 seconds!

• Successful PIN authentication only confirms that the entered PIN was recognized and correct. The output of the result code OK does not necessarily imply that the mobile is registered to the desired network.

Typical example: PIN was entered and accepted with OK, but the ME fails to register to the network. This may be due to missing network coverage, denied network access with currently used SIM card, no valid roaming agreement between home network and currently available operators etc.

The Multi-Tech wireless modem offers various options to verify the present status of network registration: For example, the AT+COPS command indicates the currently used network. With AT+CREG you can also check the current status and activate an unsolicited result code which appears whenever the status of the network registration changes (e.g., when the ME is powered up, or when the network cell changes).

• Wait 10 seconds after PIN input before using SMS related commands.

• <pin> and <new pin> can also be entered in quotation marks (e.g., “1234”).

• To check the number of remaining attempts to enter the passwords use the AT^SPIC command.

• See AT+CPWD and AT^SPWD for information on passwords.

• See AT+CLCK and AT^SLCK for information on lock types.

5.1.1 What to Do if PIN or Password Authentication Fails?

PIN1 / PUK1:

After three failures to enter PIN 1, the SIM card is blocked (except for emergency calls). +CME ERROR: 12 will prompt the client to unblock the SIM card by entering the associated PUK (= PIN Unblocking Key / Personal

Unblocking Key). After ten failed attempts to enter the PUK, the SIM card will be invalidated and no longer operable.

In such a case, the card needs to be replaced. PIN1 consists of 4 to 8 digits, PUK1 is an 8-digit code only.

To unblock a disabled PIN1 you have two options:

• You can enter AT+CPIN=PUK1,new PIN1.

• You can use the ATD command followed by the GSM code **05*PUK*newPIN*newPIN#;.

PIN2 / PUK2:

PIN2 prevents unauthorized access to the features listed in AT+CPIN2. The handling of PIN2 varies with the provider.

PIN2 may either be a specific code supplied along with an associated PUK2, or a default code such as 0000. In either case, the client is advised to replace it with an individual code. Incorrect input of PUK2 will permanently block the additional features subject to PIN2 authentification, but usually has no effect on PIN1. PIN2 consists of 4 digits, PUK2 is an 8-digit code only.

To unblock a disabled PIN2 you have two options:

• You can enter AT+CPIN2=PUK2,new PIN2.

• You can use the ATD command followed by the GSM code **052*PUK2*newPIN2*newPIN2#;.

Time to wait before next input is allowed Number of failed attempts

1

2 st nd

3 rd

failed attempt

failed attempt

failed attempt

4

5

6 th th th

failed attempt

failed attempt

failed attempt and so forth

No time to wait

4 seconds

3 * 256 seconds

4 * 256 seconds

5 * 256 seconds

6 * 256 seconds and so forth

SIM Locks:

These are factory set locks, such as “PF”, “PN”, “PU”, “PP”, “PC”. An 8-digit unlocking code is required to operate the mobile with a different SIM card, or to lift the lock. The code can only be obtained from the provider.

Failure to enter the password is subject to the same timing algorithm as the Master Phone Code (see Table above).

Call Barring:

Supported modes are “AO”, “OI”, “OX”, “AI”, “IR”, “AB”, “AG”, “AC”. If the call barring password is entered incorrectly three times, the client will need to contact the service provider to obtain a new one.

Related Sections:

“+CME ERROR: <err>” values are specified at Section 2.12.1, CME/CMS Error Code Overview. For further instructions and examples see AT+CLCK, AT^SLCK, AT+CPWD and AT^SPWD.

For a complete list of Star-Hash codes please refer Section 20.2, Star-Hash (*#) Network Commands.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 60

Chapter 4 – Serial Interface Control Commands

5.2 AT+CPIN2 PIN2 Authentication

Description: AT+CPIN2 controls network authentication of the Multi-Tech wireless modem.

The read command returns an alphanumeric string indicating whether or not network authentication is required.

The write command allows the Multi-Tech wireless modem to store the entered password. This may be, for example, the SIM PIN2 to benefit from the features listed below or the SIM PUK2 to replace a disabled PIN2 with a new one. Note that PIN2 can only be entered if PIN1 authentication was done.

If the Multi-Tech wireless modem is requesting SIM PUK2, use <pin> to enter the PUK2, followed by <new pin> to specify the new PIN2.

Test Command Syntax: AT+CPIN2=?

Response: OK

Read Command Syntax: AT+CPIN2?

Response: +CPIN2: <code>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CPIN2=<pin>[, <new pin>]

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<pin>

Password (string type), usually SIM PIN2 or, if requested, SIM PUK2.

<new pin>

If the requested code was SIM PUK2: new password (PIN2).

See Section 5.1.1, What to do if PIN or password authentication fails? for more information about when you may need to enter the PUK.

<code>

READY ME is not pending for any password.

SIM PIN2 ME is waiting for SIM PIN2.

This <code> is returned only when PIN2 authentication has not yet been done or has failed (“+CME

ERROR:17”).

SIM PUK2 ME is waiting for SIM PUK2.

This <code> is returned only when PIN2 authentication has failed and ME is pending for SIM PUK2

(i.e., “+CME ERROR:18”).

Note:

• Functions accessible only after PIN2 authentication:

AT+CACM: Accumulated call meter (ACM) reset or query

AT+CAMM: Accumulated call meter maximum (ACMmax) set or query

AT+CLCK: Facility lock to “FD” (Fixed dialing phonebook)

AT^SLCK: Facility lock to “FD” (Fixed dialing phonebook)

AT+CPWD: Change “P2”password

AT^SPWD: Change “P2”password

AT+CPUC: Price per unit and currency table

AT+CPIN2: Enter SIM PIN2 or SIM PUK2 if requested.

For example, SIM PIN2 will be needed when you attempt to edit the “FD” phonebook and ME returns “+CME

Error 17” or “+CPIN: SIM PIN2”.

Once the required <pin> has been entered correctly, PIN2 authentication code changes to READY. After 300s, a repetition of the authentication process is required; PIN2 authentication code changes from READY to SIM PIN2.

Examples:

Example 1: Change PIN2

AT+CPWD=”P2”,”0000”,”8888”

OK

Example 2: Unblock a disabled PIN2

AT+CPIN2?

+CPIN2: SIM PUK2

OK

AT+CPIN2=12345678,8888

(where “0000” = old PIN2 and “8888” = new PIN2)

PIN2 has been disabled, PUK2 must be entered to define a new PIN2 where “12345678” is the PUK2, and “8888” the new PIN2.

Example 3: Write into “FD” phonebook

AT+CPBS=”FD”

OK

AT+CPBW=2,”+493012345678”,145,”Charly”

+CME ERROR 17 access denied due to missing PIN2 authentication

AT+CPIN2=8888

OK

AT+CPBW=2,”+493012345678”,145,”Charly”

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 61

Chapter 4 – Serial Interface Control Commands

5.3 AT^SPIC Display PIN Counter

Description: The AT^SPIC command can be used to find out whether the ME is waiting for a password and, if so, how many attempts are left to enter the password.

The execute command returns the number of attempts still available for entering the currently required password, for example the PIN, PUK, PH-SIM PUK etc.

The read command AT^SPIC? indicates which password the number of attempts stated by the execute command actually refers to. Also, the write command may be used to query the counter for a specific password: It indicates the number of attempts still available for entering the password identified by <facility>, for example the PIN, PIN2, PH-SIM PIN etc.

To check whether or not you need to enter a password use the read commands AT+CPIN?,

AT+CPIN2? and AT^SPIC?. If the response to AT+CPIN? is “READY” the counter of the execute command AT^SPIC relates to PIN2. See last example. If the responses to AT+CPIN? and AT+CPIN2? both read “READY”, no password is currently required, and the referrer of the execute command AT^SPIC is explicitly undefined.

Test Command Syntax: AT^SPIC=?

Response: OK

Read Command Syntax: AT^SPIC?

Response: ^SPIC: <code>

OK

Exec Command Syntax: AT^SPIC

Response: ^SPIC: <counter>

OK

Write Command Syntax: AT^SPIC=<facility>

Response: ^SPIC: <counter>

OK

Parameter Descriptions:

<counter>

Number of attempts left to enter the currently required password. This number will be counted down after each failure.

<facility>

Password for which the corresponding PIN counter is to be displayed.

“SC“ SIM PIN or SIM PUK. If the SIM PIN has been deactivated after three failed attempts, the counter for SIM PUK will be returned instead.

“PS“

“P2“

“PN“

<code>

“Phone code” or “device code” (cf. AT+CLCK and AT+CPWD). If incorrectly entered three times, the Master Phone Code is required to lift the lock and the number of remaining attempts for the master phonecode will be returned.

SIM PIN2 or SIM PUK2. If the SIM PIN2 has been deactivated after three failed attempts, the counter for SIM PUK2 will be returned instead.

Network Personalization

Identification of the currently required password.

SIM PIN

SIM PUK

SIM PIN2

SIM PUK2

PH-SIM PIN

ME is waiting for SIM PIN1.

ME is waiting for SIM PUK1 if PIN1 was disabled after three failed attempts to enter PIN1.

ME is waiting for PIN2, when the attempt to access PIN2 requiring features was acknowledged with +CME ERROR:17 (e.g., if the user attempts to edit the FD phonebook).

ME is waiting for PUK2 to unblock a disabled PIN2. Necessary if preceding command was acknowledged with +CME ERROR:18.

ME is waiting for phone-to-SIM card password if “PS” lock is active and user inserts other SIM card than the one used for the lock. (“PS” lock is also referred to as phone or antitheft lock).

PH-SIM PUK ME is waiting for Master Phone Code, if the above “PS” lock password was incorrectly entered three times.

PH-NET PUK ME is waiting for network personalisation unblocking password

Notes:

• Whenever the required password changes, <counter> changes to reflect that change. Please refer to the examples below.

• For passwords associated to the phone lock (“PS” lock set by user or factory) or other factory set locks, such as

“PF”, “PN”, “PU”, “PP”, “PC” the number of attempts is subject to a timing algorithm explained in AT+CPIN. If these passwords are incorrectly entered the counter first returns 3, 2 and 1 remaining attempt(s), but then gives the total number of attempts which amounts to 63 (see example below).

• See also Chapters AT+CLCK, AT+CPIN, AT+CPIN2, AT+CPWD, AT^SLCK for further information on locks and passwords.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 62

Chapter 4 – Serial Interface Control Commands

Examples:

Example 1

The user fails to provide a correct SIM PIN three times. The counter decreases each time. After the counter reaches zero, the SIM PUK is required. After each failure to enter a correct SIM PUK, the counter decreases. at+cpin?

+CPIN: SIM PIN

OK at^spic

^SPIC: 3

OK at+cpin=9999

+CME ERROR: incorrect password at^spic

^SPIC: 2

OK at+cpin=9999

+CME ERROR: incorrect password

OK at^spic

^SPIC: 1

OK at+cpin=9999

+CME ERROR: incorrect password at+cpin?

+CPIN: SIM PUK

OK at^spic

^SPIC: 10

OK at+cpin=01234567,1234

+CME ERROR: incorrect password at^spic

^SPIC: 9

OK

Currently required password is PIN1.

3 attempts left.

2 attempts left.

1 attempt left.

Now required password is PUK 1.

10 attempts left for PUK 1.

9 attempts left for PUK 1.

Example 2

Though a mobile is locked to a specific SIM card (phone lock), the user attempts to operate it with another SIM card. The user correctly enters the SIM PIN of the SIM card currently inserted, but then fails to give the “PS” lock password (PH-SIM PUK): at+cpin=9999

OK at+cpin?

+CPIN: PH-SIM PIN

OK at^spic

^SPIC: 3

OK at+cpin=4711

+CME ERROR: incorrect password at^spic?

^SPIC: 2

OK at+cpin=4712

+CME ERROR: incorrect password at^spic

^SPIC: 1

OK at^spic?

^SPIC: PH-SIM PIN

OK

ME is waiting for the phone lock password.

3 attempts left.

2 attempts left.

1 attempt left.

Displayed counter refers to phone lock password. at+cpin=4713

+CME ERROR: incorrect password at^spic

^SPIC: 63

OK at^spic?

^SPIC: PH-SIM PUK

OK at+cpin=4714

+CME ERROR: incorrect password at^spic

^SPIC: 63

OK

Displayed counter refers to master phone code.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 63

Chapter 4 – Serial Interface Control Commands

Example 3

This example shows that after successful SIM PIN1 authentication the counter of the AT^SPIC execute and read command refers to SIM PIN2; i.e., it does not reflect the status of SIM PIN1. This may be a problem if the user enters a wrong PIN1 and is not aware that the number of attempts left to enter SIM PIN1 is counted down.

+CREG: 0 at+cpin=1234

OK

+CREG: 2

+CREG: 1 at+cpin?

+CPIN: READY

The mobile ist properly registered to the network.

The AT+CPIN? read command confirms that SIM PIN1 authentication was successful. at^spic

^SPIC: 3 As SIM PIN1 authentication was successful, the counter relates to SIM PIN2 and correctly indicates that the user has 3 attempts to enter SIM PIN2.

OK

AT^SPIC?

^SPIC: SIM PIN2

OK at+clck=”SC”,0,456789

CME ERROR: incorrect password at^spic

^SPIC: 3 at+clck=”SC”,0,456789

CME ERROR: incorrect password at^spic

^SPIC: 3 at+clck=”SC”,0,456789

CME ERROR: incorrect password

+CREG: 0 at^spic

^SPIC: 10

Likewise, the read command notifies that the ME is waiting for SIM PIN2.

First attempt to enter a wrong SIM PIN1.

SIM PIN1 authentication is still valid, and the counter relates to SIM PIN2.

Second attempt to enter a wrong SIM PIN1.

SIM PIN1 authentication is still valid, and the counter relates to SIM PIN2.

Third attempt to enter a wrong SIM PIN1.

SIM PIN1 authentication is no longer valid.

This time, after the SIM PIN1 code has been disabled, the counter indicates the status of SIM PIN1 and notifies that 10 attempts are left to enter the SIM

PUK.

To avoid conflicts we recommend to use the AT^SPIC read and write commands rather than the execute command only. The read command clearly states the currently required password, and the write command may be used to get the counter for a specific <facility>, in this case for example “P2”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 64

Chapter 4 – Serial Interface Control Commands

5.4 AT+CLCK Facility Lock

Description:

Response(s):

AT+CLCK can be used to lock, unlock or interrogate a network or ME <facility>. The command can be aborted when network facilities are being set or interrogated.

Test Command Syntax: AT+CLCK=?

+CLCK:list of supported <facility>s, OK

Write Command Syntax: AT+CLCK=<facility>, <mode>[, <password>][, <class>]

Response: If <mode> is not equal 2 and command successful:

OK if <mode>= 2 and command successful:

+CLCK: <class>]

[+CLCK: <status>[, <class>]]

...]

OK

If error is related to ME functionality

ERROR

Parameter Descriptions:

<facility>

Phone security locks set by client or factory

Primarily intended for the client to take safety precautions, “SC”, “PS” and “FD” can be configured individually.

Parameter <class> is not applicable to security locks. See examples below for further details.

“SC“

“PS“

SIM (lock SIM cards). SIM requests password upon ME power-up and when this lock command is issued.

<password>: SIM PIN1.

Phone locked to SIM card. ME requests password when other than current SIM card is inserted.

“PS” lock is frequently referred to as “phone lock”, or “device lock”. Accordingly, the password may be called “phone code” or “device code”. The “PS” password is not associated with the

PUK of the SIM card. If incorrectly entered three times, the Master Phone Code is required to lift the lock. This is an 8-digit device code associated to the IMEI number of the mobile which can only by obtained from the manufacturer of the module. Once the Master Phone Code has

“FD“ been accepted, the mobile is operational, and the “PS” lock is no longer active. If needed it must be set once again.

Important Note: Multi-Tech does not lock SIM Cards.

<password>: User defined password. It is needed before the first use of <facility> “PS” and, therefore, must first be specified with AT+CPWD or AT^SPWD, if it has not been predefined by factory settings. If set by factory (e.g., for a prepaid mobile), the password is supplied by the provider or operator.

SIM fixed dialing memory: If the mobile is locked to “FD”, only the phone numbers stored to the

“FD” memory can be dialled. (Capacity of FD phonebook depending on the SIM card).

<password>: SIM PIN 2.

If a lock on the SIM fixed dialing memory is active, the following applies:

• Outgoing voice, data or fax calls can be made only to numbers stored in “FD” phonebook.

Result code depends on the type of the call:

for voice calls, indication is “+CME Error 257: Call barred”.

for data and fax calls, indication is “NO CARRIER”.

• Access to defined Supplementary Services such as Call barring, Call waiting, Call forwarding, Call hold and Multiparty is possible only if the exact corresponding public MMI

*# code for the desired service is stored in the fixed dialing number phone book and used with ATD.

AT commands for supplementary service control are barred while “FD” lock is active.

Indication is “+CME Error 257: Call barred”.

• Access to Unstructured Supplementary Services (‘USSD) is possible only if the exact desired USSD string is stored in the fixed dialing number phone book and used with ATD.

AT commands for USSD are barred while “FD” lock is active.

Indication is “+CME Error 257: Call barred”.

• SMS can be sent only to phone numbers which are stored in the “fixed dialing numbers” phonebook “FD”. Also, a valid Service Center Address (international format) must be present in “FD” to allow sending SMS at all.

Indication is “+CMS Error 302: operation not allowed”.

• GPRS commands can be used only if the “fixed dialing numbers” phonebook “FD” contains an entry with phone number “*99#”. This single entry enables all GPRS commands, including AT commands and modem compatibility commands like

“ATD*99***1#” or “ATD*98***1#”.

Indication is “+CME Error 257: Call barred”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 65

Chapter 4 – Serial Interface Control Commands

Factory Defined SIM Locks:

Typical examples of factory set SIM locks are prepaid phones or network locks, used to restrict the operation of a mobile to a specific provider or operator. The client should be aware that each of these lock types can only be unlocked if the associated password is available. For example, a mobile can be locked to accept only SIM cards from the respective provider, or even one single SIM card. Once a different SIM card is inserted the ME will prompt the client to enter a specific code. This is not the PUK of the SIM card, but usually an 8-digit code which needs to be requested from the provider.

The locks can only be set by the manufacturer and need to be agreed upon between the parties concerned; e.g., provider, operator, distributor etc. on the one side and the manufacturer on the other side.

Important Note: Multi-Tech does not lock SIM Cards.

“PF“

“PN“

“PU“

“PP“

“PC“ lock Phone to the very First SIM card – Not applicable.

Network Personalization

Network subset Personalization

Service Provider Personalization

Corporate Personalization

Supplementary Service Call Barring:

Supplementary Service “Call Barring” allows to specify conditions under which calls will be disallowed by the network. The availability of the Supplementary Services varies with the network. To benefit from call barring the client will need to subscribe them, though a limited number of call barring types may be included in the basic tariff package.

When you attempt to set a <facility> or <class> which is not provisioned, not yet subscribed to, or not supported by the module, the setting will not take effect regardless of the response returned. The responses in these cases vary with the network (for example “OK”, “+CME ERROR: Operation not allowed”, “+CME ERROR: Operation not supported” etc.). To make sure check the extended error response with AT+CEER and the lock status with

<mode>=2.

<password>: Network password supplied from the provider or operator. Usually there is one password which applies to all call barring options. For details contact your provider.

“AO“

“OX“

“AI“

“IR“

“AB“

“AG“

BAOC (Bar All Outgoing Calls) “OI“ BOIC (Bar Outgoing International Calls)

BOIC-exHC (Bar Outgoing International Calls except to Home Country)

BAIC (Bar All Incoming Calls)

BIC-Roam (Bar Incoming Calls when Roaming outside the home country)

All Barring services (applicable only for <mode>=0)

All outGoing barring services (applicable only for <mode>=0)

“AC“ All inComing barring services (applicable only for <mode>=0)

<mode>

0 unlock

1 lock

2 query status

<status>

0 lock is inactive

1 lock is active

<password>

Password string used to lock and to unlock a <facility>. Length and authority for passwords depend on the

<facility> in question and are therefore listed in the section on parameter <facility>. Passwords can be modified with AT+CPWD or AT^SPWD.

<class>

Integer or sum of integers each representing a class of information; i.e., a bearer service, telecommunication service or bearer service group as defined in “GSM 02.04”.

1 voice

2 class 2 (“data”) comprises all those individual data classes between 16 and 128, that are supported both by the network and the MS. This means, a setting made for class 2 applies to all individual data classes (if supported). In addition, you can assign a different setting to a specific class. For example, you can activate

Call Forwarding for all data classes, but deactivate it for data class 64, “dedicated packet access”.

4 fax

8 SMS

16 data circuit sync

32 data circuit async

64 dedicated packet access

128 dedicated PAD access

1-55 Default 7. Combination of some of the above classes. For example, the default setting 7 represents the sum of the integers 1, 2 and 4 (voice, data and fax). The value 255 covers all classes.

If parameter “class” is omitted, the default value 7 is used.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 66

Chapter 4 – Serial Interface Control Commands

Notes:

• The AT+CLCK command offers the full range of <class> parameters according to the GSM specifications.

However, when you attempt to use a service option which is not provisioned or not yet subscribed to, the setting will not take effect regardless of the response returned.

The responses in these cases vary with the network (for example “OK”, “Operation not allowed”, “Operation not supported” etc.). To make sure check the extended error response with AT+CEER and the lock status with

<mode>=2.

• The command has been implemented with the full set of <class> parameters according to GSM 07.07. For actual applicability of a desired Call barring service to a specific service or service group (a specific <class> value) please consult table A.1 of GSM 02.04.

• If an outgoing Fax or Data Call is rejected due to an active “call barring” supplementary service, the call will be terminated with result code NO CARRIER.

Under the same conditions, an outgoing Voice call will be terminated with result code NO DIALTONE.

• If an invalid <password> is entered several times in succession, a delay incremented after each failed attempt will increase the time to wait before the input of the <password> is accepted. To avoid blocking the serial interface the running AT+CLCK command is aborted after a short timeout and returns CME ERROR 100

(“unknown”). If then the AT+CLCK command is issued once again execution is denied with CME ERROR 256

(“Operation temporary not allowed”). For details regarding the delay see Section 5.1.1, What to do if PIN or password authentication fails?.

• If the user tries to set a lock although it is already active or, the other way round, tries to unlock an inactive lock, the response will be OK, but the <password> will not be checked or verified.

• In the airplane mode the write command version for the network related <facility> (AO, OI, OX, AI, IR, AB, AG and AC) is not supported. For remaining facilities the command is fully functional then.

Examples

Example 1: Lock SIM card (<facility>= “SC”)

AT+CLCK=”SC”,1,”9999” The “SC” parameter enables or disables the SIM PIN authentication (PIN 1) when you power up the GSM engine

OK

AT+CLCK=”SC”,0,”9999”

OK

SIM card locked. As a result, SIM PIN 1 must be entered to enable ME to register to the

GSM network.

Unlocks SIM card.

When powered up, ME registers to the GSM network without requesting SIM PIN1.

Note: Depending on the services offered by the provider, this feature is not supported by all

SIM card types. If so, the command returns ERROR when you attempt to unlock the card.

To query the status of the SIM card lock:

AT+CLCK=”SC”,2

+CLCK: 1

OK

Query the status of SIM card lock.

SIM card is locked. SIM PIN1 must be entered to enable ME to register to the GSM network.

Example 2: Phone Lock (<facility>=”PS”)

AT+CPIN?

OK

Make sure that PIN1 authentication is valid.

To lock the ME to the currently inserted SIM card, first specify a password for <facility> “PS”:

AT+CPWD=”PS”,,”1234”

OK

If “PS” lock has not been set before: enter new password.

Optionally, if “PS” password was defined before, change existing password:

AT+CPWD=”PS”,”1234”,”3333” To replace existing “PS” password: Enter old and new password.

OK

Then, activate the Phone Lock:

AT+CLCK=”PS”,1,”3333”

OK

Locks the mobile to the current SIM card.

To operate the mobile with the SIM card for which “PS” lock was activated:

AT+CPIN?

+CPIN: SIM PIN

OK

AT+CPIN=”9999”

OK No additional password is required for operation (SIM recognized by mobile).

To operate the mobile with other SIM card than the one used for the “PS” lock:

Enter SIM PIN of present card, followed by “PS” lock password.

AT+CPIN?

+CPIN: SIM PIN

OK

AT+CPIN=”1111”

OK

AT+CPIN?

+CPIN: PH-SIM PIN

OK

AT+CPIN=”3333”

OK

PIN authentication accepted.

“PS” lock password is required.

“PS” Lock password has been accepted. ME is fully operational now.

To deactivate the Phone Lock:

AT+CLCK=”PS”,0,”3333”

OK

Phone Lock password has to be provided again.

Now the mobile can be used with any SIM card, without the need of the phone lock password.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 67

Chapter 4 – Serial Interface Control Commands

5.5 AT^SLCK Facility Lock

Description: AT^SLCK provides the “Facility lock” function as defined for the GSM 07.07 command

AT+CLCK. The command can be used to lock, unlock or interrogate a network or ME <facility>.

AT^SLCK is, in every respect, identical with AT+CLCK, except that the command syntax and response prefix is “^SLCK” instead of “+CLCK”. For further details please refer to AT+CLCK.

The command can be aborted when network facilities are being set or interrogated.

Test Command Syntax: AT^SLCK=?

Response(s): ^SLCK:list of supported <facility>s, OK

Write Command Syntax: AT^SLCK=<facility>, <mode>[, <password>][, <class>]

Response(s):

Note: if <mode> is not equal 2 and command successful: OK if <mode>=2 and command successful: ^SLCK: <status>, <class>

[^SLCK: <status>, <class>]

[^SLCK: ...]

OK

If error is related to ME functionality: +CME ERROR

In the airplane mode the write command version for the network related <facility> (AO, OI, OX, AI, IR, AB, AG and

AC) is not supported. For remaining facilities the command is fully functional then.

5.6 AT+CPWD Change Password

Description: AT+CPWD allows to define a new password for a password protected <facility> lock function.

Each password is a string of digits, the length of which varies with the associated <facility>. The test command returns a list of pairs which represent the available facilities and the maximum length of the associated password. See AT commands AT+CLCK and AT^SLCK for more information on the various lock features.

Specifically the command can be used to • change PIN1 or PIN2,

• change the password supplied from your provider for the “call barring” supplementary service,

• set individual phone security passwords,

• enter the unblocking key (Master Phone Code) to restore a disabled “PS” password.

To delete a password use the following syntax: at+cpwd=<facility>,<old password>

Test Command Syntax: AT+CPWD=?

Response(s): +CPWD : (list of supported (<facility>, <password length>), OK

Write Command Synatx: AT+CPWD=<facility>, <old password>[, <new password>]

Response(s): New password has been registered for the facility lock function.

OK

If parameter <old password> was not correct:

+CME ERROR 16 (+CME ERROR: incorrect password)

Parameter Descriptions:

If the password for the selected <facility> has been invalidated due to too many failed attempts: +CME ERROR ...

If error is related to ME functionality: +CME ERROR

<facility>

Phone security locks set by client or factory:

Primarily intended for the client to take safety precautions. Passwords “SC” (SIM PIN) and “P2” (SIM PIN2) are usually predefined, but can be configured individually. The lock facility password “PS” may also be factory set.

“SC“ SIM PIN. SIM requests password upon ME power-up and when this lock command is issued.

If incorrectly entered three times, the SIM PUK is required to perform authentication.

Input of the SIM PUK password is possible only with AT command AT+CPIN or ATD. For further details please refer to Section 5.1.1, What to do if PIN or password authentication fails?.

“PS“

<password length>: 4 to 8 digits.

Phone locked to SIM card. ME requests password when other than current SIM card is inserted.

“PS” lock is frequently referred to as “phone lock”, or “device lock”. Accordingly, the password may be called “phone code” or “device code”. The “PS” password is not associated with the PUK of the SIM card. It must be defined before the first use of <facility> “PS” with AT+CLCK.

<password length>: 4 digits.

If incorrectly entered three times, the Master Phone Code is required to lift the lock. This

Unblocking procedure is performed with AT+CPWD using the following parameters:

<facility>=”PS”, <old password>= Master Phone Code (to be obtained from the module manufacturer) and <new password>= the new phone code (“PS” password for lock facility), if desired.

Mind that successful PIN authentication is a prerequisite for use of AT command AT+CPWD. If

Pin authentication has not been completed, input of the Master Phone code password is possible only with AT command AT+CPIN or ATD. For further detail please refer to Section 5.1.1, What to do if PIN or password authentication fails?.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 68

Chapter 4 – Serial Interface Control Commands

“P2“

Once the Master Phone Code has been acctepted, the mobile is operational and the “PS” lock is no longer active. If needed it must be set once again with AT+CLCK.

SIM PIN 2; e.g., required for authentication with facility lock “FD” (cf. AT+CLCK).

If incorrectly entered three times, the SIM PUK 2 is required to perform authentication.

Input of the SIM PUK 2 password is possible only with AT command AT+CPIN2 or ATD. For further detail please refer to Section 5.1.1, What to do if PIN or password authentication fails?.

<password length>: 4 to 8 digits.

Factory-Defined SIM Locks:

Typical examples of factory set SIM locks are prepaid phones or network locks, used to restrict the operation of a mobile to a specific provider or operator. The client should be aware that each of these lock types can only be unlocked if the associated password is available. For example, a mobile can be locked to accept only SIM cards from the respective provider, or even one single SIM card. Once a different SIM card is inserted the ME will prompt the client to enter a specific code. This is not the PUK of the SIM card, but usually an 8-digit code which needs to be requested from the provider.

The locks can only be set by the manufacturer and need to be agreed upon between the parties concerned; e.g., provider, operator, distributor etc. on the one side and the manufacturer on the other side.

“PF“

“PN“

“PU“

“PP“

“PC“

Lock Phone to the very First SIM card – Not applicable.

Network Personalization

Network subset Personalization

Service Provider Personalization

Corporate Personalization

Supplementary Service Call Barring:

Supplementary Service “Call Barring” allows to specify conditions under which calls will be disallowed by the network. The availability of the Supplementary Services varies with the network. To benefit from call barring the client will need to subscribe them, though a limited number of call barring types may be included in the basic tariff package.

<password length>: The Network Password needs to be supplied from the network provider or network operator.

Usually there is one 4 digit password which applies to all call barring options. For details contact your provider.

“AO“

“OI“

“OX“

“AI“

BAOC (Bar All Outgoing Calls)

BOIC (Bar Outgoing International Calls)

BOIC-exHC (Bar Outgoing International Calls except to Home Country)

BAIC (Bar All Incoming Calls)

“IR“

“AB“

“AG“

“AC“

BIC-Roam (Bar Incoming Calls when Roaming outside the home country)

All Barring services

All outGoing barring services

All inComing barring services

<password length>

4...8 Length of password. The range of permitted length for a password depends on the associated

<facility>. It is available from the test command response or in the description of <facility>.

<old password>

Password specified for the facility.

Parameter <old password> can be ignored if no old password was allocated to the facility.

Take into account that a password may have already been set by factory, or that the service is subject to a password issued by the provider. See notes above or contact provider.

<new password>

New password. Mandatory, if <old password> was an unblocking key (such as the Master Phone Code).

Notes:

• When changing PIN2 (<facility>=”P2”), it is recommended to check the new state of PIN2 by using AT+CPIN2.

• In the airplane mode the write command version for the network related <facility> (AO, OI, OX, AI, IR, AB, AG and

AC) is not supported. For remaining facilities the command is fully functional then.

Examples

Example 1: To change PIN2

AT+CPWD=”P2”,”0000”,”8888”

OK

(where “0000” = old PIN2 and “8888” = new PIN2)

PIN2 Password has been changed to “8888”

Example 2: To set password used to enable or disable barring of all outgoing calls:

AT+CPWD=”AO”,”0000”,”3333”

OK

Requests the network to change the password for supplementary service “call barring”.

Usually this request will affect all barring services, even though the request is issued for Supplementary Service BAOC (“Barring of all outgoing calls”) only.

Refer to the respective network provider for detail.

Example 3: Handling of the “PS” lock password

AT+CMEE=2

AT+CPWD=”PS”,”1111”,”2222”

OK

AT+CPWD=”PS”,”1111”,”2222”

+CME ERROR: incorrect password

Enable text output of CME Error information

(where “1111” = old password and “2222” = new password)

Password for facility “PS” is now “2222”

Repeat command to provoke error “incorrect password”

(“1111” is no longer the correct password)

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 69

Chapter 4 – Serial Interface Control Commands

Example 4: To specify a new “PS” lock password

To specify a new “PS” lock password, after the old password was disabled (e.g., after three failed attempts to change the “PS” password): use the master phone code.

CAUTION: THIS TEST SHOULD BE PERFORMED ONLY IF THE CORRECT MASTER PHONE CODE FOR

THE INDIVIDUAL ME USED IS DEFINITELY AVAILABLE! Otherwise, the module used will be rendered useless until the correct master phone code is entered:

AT+CPWD=”PS”,”12345678”,”1111” where 12345678 is the Master Phone Code and 1111 is the new password. You may also use <new password> to restore the former disabled password.

OK

Alternatively, without giving a new password:

AT+CPWD=”PS”,”12345678” (where 12345678 is the Master Phone Code). Deactivates the present phone lock.

OK

5.7 AT^SPWD Change Password

Description: The AT^SPWD command is, in every respect, identical with AT+CPWD, except that the command syntax and response prefix is “^SPWD” instead of “+CPWD”. For further description please refer to

AT+CPWD. See also AT commands AT+CLCK and AT^SLCK for more information on the various lock features.

The write AT^SPWD command allows to define a new password for a password protected <facility> lock function.

Each password is a string of digits, the length of which varies with the associated <facility>. The test command returns a list of pairs which represent the available facilities and the maximum length of the associated password.

Use this command when you want to change the passwords defined for the “facility lock” functions available from AT+CLCK. Specifically the command can be used to • change PIN1 or PIN2,

• change the password supplied from your provider for the “call barring” supplementary service,

• set individual phone security passwords,

• enter the unblocking key (Master Phone Code) to restore a disabled “PS” password.

See also AT Commands AT+CLCK and AT^SLCK for more information on the vaious lock features.

Test Command Syntax: AT^SPWD=?

Response: ^SPWD : list of supported (<facility>, <password length>)

OK

Write Command Syntax: AT^SPWD= <facility> [,<old password>][, <new password>]

Response: New password has been registered for the facility lock function: OK

If parameter <old password> was not correct: +CME ERROR 16 (+CME ERROR: incorrect password)

If the password for the selected <facility> has been invalidated due to too many failed attempts: +CME ERROR ...

When trying to set a “CM” password even though another type of factory set SIM lock is already active: +CME ERROR: Operation not supported.

If error is related to ME functionality: +CME ERROR

Note: When changing the PIN2 (<facility>=”P2”), it is recommended to check the new state of

PIN2 using the AT+CPIN2 command.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 70

Chapter 6 – Identification Commands

Chapter 6. Identification

Commands

The AT Commands described in this chapter allow the external application to obtain various identification information related to the Multi-Tech wireless modem and linked entities.

6.1 ATI Display Product Identification

Information

Description: The ATI execute command delivers a product information text.

The ‘Revision’ information consists of the following parts: Version xx and variant yy of software release.

Exec Command Syntax: ATI

Response: SIEMENS

MC75 xx.yy

OK

Exec Command Syntax: ATI[<value>]

Response: OK

Parameter Description: <value> Values are not support and only return OK.

6.2 AT+CGMI Request Manufacturer

Identification

Description: AT+CGMI returns a manufacturer identification text. See also: AT+GMI.

Test Command Syntax: AT+CGMI=?

Response: OK

Exec Command Syntax: AT+CGMI

Response: SIEMENS

OK

6.3 AT+GMI Request Manufacturer Identification

Description: AT+GMI returns a manufacturer identification text. See also: AT+CGMI.

Test Command Syntax: AT+GMI=?

Response: OK

Exec Command Syntax: AT+GMI

Response: SIEMENS

OK

6.4 AT+CGMM Request Model Identification

Description: AT+CGMM returns a product model identification text. Command is identical with

AT+GMM.

Test Command Syntax: AT+CGMM=?

Response: OK

Exec Command Syntax: AT+CGMM

Response: MC75

OK

6.5 AT+GMM Request Model Identification

Description: AT+GMM returns a product model identification text. Command is identical with

AT+CGMM.

Test Command Syntax: AT+GMM=?

Response: OK

Exec Command Syntax: AT+GMM

Response: MC75

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 71

Chapter 6 – Identification Commands

6.6 AT+CGMR Request Revision Identification

Description: AT+CGMR delivers a product firmware version identification. Command is identical with

AT+GMR.

Test Command Syntax: AT+CGMR=?

Response: OK

Exec Command Syntax: AT+CGMR

Response: REVISION <xx.yy>

OK

Parameter Description:

<xx.yy>

Version xx and variant yy of software release.

6.7 AT+GMR Request Revision Identification

Description: AT+GMR delivers a product firmware version identification. Command is identical with

AT+CGMR.

Test Command Syntax: AT+GMR=?

Response: OK

Exec Command Syntax: AT+GMR

Response: REVISION <xx.yy>

OK

Parameter Description:

<xx.yy>

Version xx and variant yy of software release.

6.8 AT+CGSN Request International Mobile

Equipment Identity

Description: AT+CGSN delivers the International Mobile Equipment Identity (IMEI). Command is identical with: AT+GSN.

Test Command Syntax: AT+CGSN=?

Response: OK

Exec Command Syntax: AT+CGSN

Response: <sn>

OK

Parameter Description:

<sn>

International Mobile Equipment Identity (IMEI) used to identify a GSM mobile equipment to the GSM network.

6.9 AT+GSN Request International Mobile

Equipment Identity

Description: AT+GSN delivers the International Mobile Equipment Identity (IMEI). Command is identical with AT+CGSN

Test Command Synatx: AT+GSN=?

Response: OK

Exec Command Syntax: AT+GSN

Response: <sn>

OK

Parameter Description:

<sn>

International Mobile Equipment Identity (IMEI) used to identify a GSM mobile equipment to the GSM network.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 72

Chapter 6 – Identification Commands

6.10 AT+CIMI Request International Mobile

Subscriber Identity

Description:

Response:

AT+CIMI delivers the International Mobile Subscriber Identity (IMSI). The IMSI permits the

TE to identify the individual SIM attached to the ME.

Test Command Syntax: AT+CIMI=?

OK

Exec Command Synatx: AT+CIMI

Response: <imsi>

OK

ERROR

Parameter Description:

+CME ERROR: <err>

<imsi>

International Mobile Subscriber Identity (string without quotes).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 73

Chapter 7 – Call-Related Commands

Chapter 7. Call-Related Commands

The AT Commands described in this chapter are related to Mobile Originated Calls (MOC; i.e., outgoing) and Mobile

Terminated Calls (MTC; i.e., incoming).

7.1 Call Status Information

For Circuit switched calls, including voice, fax and data calls, call status information is available with URC “+CIEV: call” (configurable via AT commands AT+CIND and AT+CMER) or - in more detail - from the list of current calls. This list can be displayed on request via at commands AT+CLCC and AT^SLCC. It can also be issued by the ME in the form of an unsolicited result code “^SLCC” if configured with AT^SLCC and AT+CMER.

URC “+CIEV: call” and URC “^SLCC” can be configured using AT command AT^SCFG. An overview of the possible configurations and their consequences for the availability of call status information will be given here.

Generally speaking, the call status values recognized by the ME are as follows:

• active

• held

• dialing (MOC)

• alerting (MOC)

• incoming (MTC)

• waiting (MTC)

• terminating: The call is not active anymore, but inband information is still available.

• dropped: The call has been suspended by the network, but may be resumed later.

The values “terminating” and “dropped” are not standardized for AT command AT+CLCC, and, therefore, only available for command AT^SLCC. A call in any of these two states will not appear in the list of current calls as displayed with AT+CLCC.

A call that is not recognized by the ME is considered to be in “unknown” state.

Some networks may schedule a traffic channel for a call that is not yet in the “active” state. This is reflected in parameter <traffic channel assigned> of AT command AT^SLCC and the corresponding URC.

Depending on the value of AT^SCFG setting <succ>, Indicator “+CIEV” will be issued (if configured with

AT+CIND and AT+CMER)

• when a state transition ends in state “active” or in state “unknown”

(if AT^SCFG setting <succ>=”restricted”).

• when any state transition (including transitions beginning or ending in state “unknown”) occurs in the list of active calls, or when a traffic channel is established (if AT^SCFG setting <succ>=”verbose”).

The value for indicator “+CIEV: call” will be “1” if at least one call is in states “held” or “active”, and “0” otherwise.

Depending on the value of AT^SCFG setting <sucs>, indicator “^SLCC” will be issued (if configured with write command AT^SLCC and AT+CMER).

• when a state transition ends in state “active” or in state “unknown” (if AT^SCFG setting <sucs>=”restricted”)

• when any state transition (including transitions beginning or ending in state “unknown”) occurs in the list of active calls, or when a voice channel is established (if AT^SCFG setting <sucs>=”verbose”).

Due to compatibility considerations, the powerup default for AT^SCFG setting <succ> is “restricted”, offering compatibility to the standard behaviour of indicator “+CIEV: call”, while the default for setting <sucs> is “verbose”.

In order to see the URCs, event reporting for both indicators must be configured with the appropriate AT commands.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 74

Chapter 7 – Call-Related Commands

7.2 ATA Answer a Call

Description: TA causes remote station to go off-hook (e.g., answer call).

Exec Command Syntax: ATA

Response:

CONNECT

Parameter Description:

In case of data call, if successfully connected (TA switches to data mode):

<text>

In case of voice call, if successfully connected: OK

When TA returns to command mode after call release: OK

If no connection: NO CARRIER

<text>

Connection status

<text> output only if ATX parameter setting with value greater 0.

Notes

• Any additional commands on the same command line are ignored.

• The command may be aborted generally by receiving a character during execution. It can’t be aborted in some connection setup states, such as handshaking.

• If AT+FCLASS setting is 1 or 2, all incoming calls will be answered as fax calls, when ATA is issued on multiplexer channel 1 resp. ASC0. For calls explicitly signalled as voice or data calls, this procedure will fail with result code “NO CARRIER”, but the call in question will continue to ring. It is possible to change the setting for

AT+FCLASS to 0 while the call is ringing, and accept the call normally afterwards with ATA.

• The ATA command may be used also to accept a network request for a PDP context activation (see ATA).

• See also ATX for <text>.

• If an incoming call is no longer available (already disconnected/hang up), a “NO CARRIER” result code will be given.

7.3 ATD Mobile Originated Call to a Specified

Number

Description: This command can be used to set up outgoing voice, data or fax calls. It also serves to control

Supplementary Services. The termination character “;” is mandatory to set up voice calls or to send *# codes for Supplementary Services. It must not be used for data and fax calls.

Additional notes on the responses returned after dialing with ATD:

• For voice calls, you have the choice of two different response modes that can be selected with AT^SM20:

AT^SM20=1 (factory default) causes the ME to respond once the call setup is completed either successfully (“OK”) or unsuccessfully (“NO CARRIER”, “NO DIAL TONE”, “BUSY”).

AT^SM20=0 causes the ME to return “OK” immediately after dialing was completed (i.e., before call setup terminates successfully or unsuccessfully).

• For data connections, call setup always terminates when the call has been established

(indicated by the result code “CONNECT <text>), or when it fails (indicated by “NO

CARRIER”). The settings of AT^SM20 do not apply.

Different call release indications:

• Upon termination, an outgoing fax or data call may show a different result code than a voice call would show under identical conditions. In order to track down the actual reason for call termination, AT+CEER or ATS18 should be used for all applicable connections.

Using ATD during an active call:

• When a user originates a second voice call whil there is already an active voice call, the first call will automatically put on hold. The second call attempt is acknowledged with “OK” immediately after dialing with ATD has completed, without relation to a successful call setup.

In case of failure, the additional result codes “NO CARRIER”, “NO DIAL TONE”, “NO

CARRIER” will be presented afterwards (see example below).

Exec Command Syntax: ATD<n>[<mgsm>][;]

Response: If no dialtone (parameter setting ATX2 or ATX4): NO DIALTONE

If busy (parameter setting ATX3 or ATX4): BUSY

If a connection cannot be set up: NO CARRIER

OK

If successfully connected and non-voice call (TA switches to online data mode):

CONNECT <text>

When TA returns to command mode after call release: OK

If successfully connected and voice call: OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 75

Chapter 7 – Call-Related Commands

Parameter Description:

<n>

String of dialing digits and optional V.250 modifiers: 0-9, *, #, +, A, B, C

The following V.250 modifiers are ignored: ,(comma), T, P, !, W ,@

Emergency call : <n> = 112, 911 or 08, standardized GSM emergency number (no SIM needed).

<mgsm>

String of GSM modifiers:

I Activates CLIR (disables presentation of own phone number to called party) i Deactivates CLIR (enables presentation of own phone number to called party)

G Activate Closed User Group explicit invocation for this call only. g Deactivate Closed User Group explicit invocation for this call only.

Notes:

• The command may be aborted generally when receiving a character during execution. It cannot be aborted in some connection setup states, such as handshaking.

• Parameter “I” and “i” only if no *#-code is within the dial string.

• <mgsm> is not supported for data calls.

• <n> is default for last number that can be dialled by ATDL.

• See also ATX for <text>.

• If ATD is used with a USSD command (e.g., ATD*100#;) an AT+CUSD=1 is executed implicitly (see AT+CUSD).

• Parameter ‘G’ or ‘g’ will be ignored if Closed User Group was already activated, respectively deactivated with

AT+CCUG command before. Call by call invocation of CUG uses the settings provisioned by the provider or, if available, the settings of the parameters <index> and <info> made with AT+CCUG.

• The ME is equipped with a “Blacklist” function according to GSM02.07 Annex A:

After a predefined number of failed call attempts, the dialed number is entered into a read-only phonebook called

“blacklist” (phonebook “BL”). Call attempts to numbers contained in the blacklist will be barred by ME and not signalled to the network.

An attempt to start a voice call to a barred phone number will be stopped with a CME ERROR 257 “Call Barred”.

An attempt to start a data or fax call to a barred phone number will be answered immediately with result code

“NO CARRIER”.

The barred numbers are automatically removed from the blacklist according to the timing conditions specified in

GSM02.07 Annex A.

Example:

The following example shows the call setup procedure when a call is already active and a second call attempt fails because the line of the called party is busy: atd03012345678

OK

Dialing out the first party’s number.

The first call is established.

ATD03022222222

OK

BUSY

The number of the second party is dialed.

The response “OK” is issued immediately though no call is established

(same behavior as is you had chosen AT^SM20=0.)

Line of the second called party is busy.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 76

Chapter 7 – Call-Related Commands

7.4 ATD><mem><n> Mobile Originated Call Using

Specific Memory and Index Number

Description: TA attempts to set up an outgoing call to the specified number. The termination character “;” is mandatory since dialing from a phonebook is only supported for voice calls and for sending *# codes of Supplementary Services or other functions.

Exec Command Syntax: ATD><mem><n>[<mgsm>];

Response(s): ERROR

+CME ERROR: <err>

If no dialtone (parameter ATX2 or ATX4):

NO DIALTONE

If busy (parameter setting ATX3 or ATX4):

BUSY

If connection cannot be set up:

NO CARRIER

When TA returns to command mode after call release:

OK

If successfully connected:

OK

Parameter Descriptions:

<mem>

Phonebook storage: For detailed description of storages see AT+CPBS.

“FD“ Fixed dialing phonebook phonebook.

“ON“ MSISDN list

“ME“ Mobile Equipment Phonebook

“LD“ Last number dialed phonebook

“MC“ Missed (unanswered received) calls list

“RC“ Received calls list

<n>

Integer type memory location in the range of locations available in the selected memory; i.e., the index number returned by AT+CPBR.

<mgsm>

String of GSM modifiers:

I i

Notes:

Activates CLIR (disables presentation of own phone number to called party)

Deactivates CLIR (enables presentation of own phone number to called party)

• This command may be aborted generally by receiving a character during execution. Abortion is not possible during some states of connection setup such as handshaking.

• There is no <mem> for emergency call (“EN”).

• The command is not applicable to data calls. Any attempt to dial a data call number from <mem> causes the result code “NO CARRIER” to appear.

• Parameter <mgsm> only if no *# code is within the dialing string.

• See ATX for setting result code and call monitoring parameters.

Examples:

Example 1

To query the location number of the phonebook entry:

TA returns the entries available in the active phonebook.

Example 2

To dial a number from the SIM phonebook, for example the number stored to location 15:

Example 3

To dial a phone number stored in the last dial memory on the SIM card:

AT+CPBR=1,xx

ATD>SM15;

OK

ATD>LD9;

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 77

Chapter 7 – Call-Related Commands

7.5 ATD><n> Mobile Originated Call from Active

Memory Using Index Number

Description: TA attempts to set up an outgoing call to the stored number. The termination character “;” is mandatory since dialing from a phonebook is only supported for voice calls and for sending *# codes of Supplementary Services or other functions.

Exec Command Synatx: ATD><n>[<mgsm>];

Response(s): ERROR

+CME ERROR: <err>

If no dialtone (parameter ATX2 or ATX4): NO DIALTONE

If busy (parameter setting ATX3 or ATX4): BUSY

If connection cannot be set up: NO CARRIER

When TA returns to command mode after call release: OK

If successfully connected: OK

Parameter Descriptions:

<n>

Integer type memory location in the range of locations available in the selected memory; i.e., the index number returned by AT+CPBR.

<mgsm>

String of GSM modifiers:

I Activates CLIR (disables presentation of own phone number to called party) i Deactivates CLIR (enables presentation of own phone number to called party)

Notes:

• This command may be aborted generally by receiving a character during execution. Abortion is not possible during some states of connection setup such as handshaking.

• The command is not applicable to data calls. Attempting to dial a data call number from <n> causes the result code “NO CARRIER” to appear.

• Parameter <mgsm> only if no *# code is within the dialing string.

7.6 ATD><str> Mobile Originated Call from Active

Memory Using Corresponding Field

Description: This command searches the active phonebook for a given string <str> and dials the assigned phone number.

The termination character “;” is mandatory since dialing from a phonebook is only supported for voice calls and for sending *# codes of Supplementary Services or other functions.

Exec Command Syntax: ATD><str>[<mgsm>];

Response: ERROR

+CME ERROR: <err>

If no dialtone (parameter ATX2 or ATX4): NO DIALTONE

If busy (parameter setting ATX3 or ATX4): BUSY

If connection cannot be set up: NO CARRIER

When TA returns to command mode after call release: OK

If successfully connected: OK

Parameter Descriptions:

<str>

String type value (“x”), which should equal an alphanumeric field in at least one phonebook entry in the searched memories; used character set should be the one selected with AT+CSCS. <str> can contain escape sequences as described in chapter “Supported character sets”.

<str> must be wrapped in quotation marks (“”), if escape sequences or parameter <mgsm> are used or if the alphanumeric strings contains a blank. If not, quotation marks are optional.

If AT+CSCS is set to “UCS2”, with respect to the coding of UCS2-characters only phonebook entries that contain an alphanumeric string with as size less than the half of the parameter <tlength> from AT+CPBW can be dialed.

<mgsm>

String of GSM modifiers:

I Activates CLIR (disables presentation of own phone number to called party)

Notes i Deactivates CLIR (enables presentation of own phone number to called party)

• This command may be aborted generally by receiving a character during execution. Abortion is not possible during some states of connection setup such as handshaking.

• The command is not applicable to data calls. Any attempt to dial <str> without semicolon “;” causes the result code “NO CARRIER” to appear.

• Parameter <mgsm> only if no *# code is within the dialing string.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 78

Chapter 7 – Call-Related Commands

7.7 ATDI Mobile Originated Call to ISDN Number

Description: TA attempts to set up an outgoing call to ISDN number. The termination character “;” is mandatory to set up voice calls or to send *# codes for Supplementary Services. It must not be used for data and fax calls.

Exec Command Syntax: ATDI<n>[;]

Response: If no dialtone (parameter ATX2 or ATX4): NO DIALTONE

If busy (parameter setting ATX3 or ATX4): BUSY

If connection cannot be set up: NO CARRIER

All other error reasons: +CME ERROR

If successfully connected and non-voice call (TA switches to data state):

CONNECT <text>

When TA returns to command mode after call release: OK

If successfully connected and voice call: OK

Parameter Description:

<n>

ISDN number String with maximum length of 20 characters. Allowed characters: +, 0-9, A, B, C.

Note:

• This command may be aborted generally by receiving a character during execution. Abortion is not possible during some states of connection setup such as handshaking.

7.8 ATDL Redial Last Number Used

Description:

Exec Command:

Response:

This command redials the last voice and data call number used in the ATD command. If terminated with semicolon, ATDL dials the last voice call number stored in the “LD” phonebook.

Otherwise, the last dialed data or fax number will be used (not contained in the “LD” phonebook).

ATDL[;]

If there is no last number or number is not valid: +CME ERROR

If no dialtone (parameter ATX2 or ATX4): NO DIALTONE

If busy (parameter setting ATX3 or ATX4): BUSY

If connection cannot be set up: NO CARRIER

If successfully connected and non-voice call (TA switches to online data mode):

CONNECT <text>

When TA returns to command mode after call release: OK

If successfully connected and voice call: OK

Notes:

• This command may be aborted generally by receiving a character during execution. Abortion is not possible during some states of connection setup such as handshaking.

• Parameter “I” and “i” only if no *#-code is within the dial string.

7.9 ATH Disconnect Existing Connection

Description: Disconnect existing call from command line by local TE and terminate call.

Exec Command Syntax: ATH[<n>]

Response:

Parameter Description:

<n>

0

OK disconnect from line and terminate call

Notes:

• OK is issued after circuit 109 (DCD) is turned off, if it was previously on.

• ATH terminates every circuit switched call (voice, data or fax), even if it is issued via another interface. This behavior is in accordance with ITU-T V.250; (07/97, “Hook control”: “ATH is terminating any call in progress.”).

• ATH clears any active PDP context or terminates any existing PPP connection, but only if issued on the same interface where GPRS is used and if there is no pending network request for PDP context activation. It does not affect PDP contexts and PPP connections on other interfaces (see also Chapter “ATH Manual rejection of a network request for PDP context activation”).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 79

Chapter 7 – Call-Related Commands

7.10 AT+CHUP Hang Up Call

Description: Cancels all active and held calls.

Test Command Syntax: AT+CHUP=?

Response(s): OK, ERROR, +CME ERROR

Exec Command Syntax: AT+CHUP

Response(s):

Note:

OK, ERROR, +CME ERROR

AT+CHUP implements the same behavior as ATH.

7.11 AT^SHUP Hang Up Call(s) Indicating a Specific

GSM04.08 Release Cause

Description: The write command serves to end one specific call or all calls known to the ME, indicating a specific GSM04.08 release cause specified by the user. The command can be used for voice, fax, and data calls in any call status (i.e., any calls listed by AT+CLCC).

Test Command Syntax: AT^SHUP=?

Response(s): OK

Write Command Syntax: AT^SHUP=<cause>[, <cn>]

Response(s):

Parameter Descriptions:

ERROR, OK

<cause>

Release Cause

Release cause from GSM04.08 to be indicated to the network.

The Multi-Tech wireless modem will release the selected connection(s) with release cause indication “cause” and location “user” (0) in the “disconnect” protocol message to the GSM Network. It depends on the network whether or not the release cause will be forwarded to the remote party.

1

16

17

18 send GSM04.08 release cause “unassigned (unallocated) number” send GSM04.08 release cause “Normal call clearing “ send GSM04.08 release cause “User busy “ send GSM04.08 release cause “No user responding “

27

31

<cn>

Call Number send GSM04.08 release cause “Destination out of order “ send GSM04.08 release cause “Normal, unspecified”

The “call number” is an optional index into the list of current calls available via AT+CLCC. AT command

AT^SHUP will terminate the call identified by the specified call number. The default call number “0” is not assigned to any call, but signifies “all calls”. As “0” is the default value, it may be omitted.

With AT^SHUP, Calls will be terminated regardless of their current call status, which may be any of the states allowed by AT+CLCC.

0 terminate all known calls. Default.

1...7

Notes: terminate the specific call number <cn>

• it depends on the network whether or not a delivered release cause will be forwarded to the remote party.

With AT^SHUP, Calls will be terminated regardless of their current call status, which may be any of the states allowed by AT+CLCC.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 80

Chapter 7 – Call-Related Commands

7.12 ATS0 Set Number of Rings before

Automatically Answering a Call

Description: This command determines the number of rings before automatic answering a call.

Read Command Syntax: ATS0?

Response(s): <n>

OK

ERROR

Write Command Syntax: ATS0=<n>

Response(s): OK

ERROR

Parameter Description:

<n>

000 Automatic answer mode is disabled. Default.

001-255 Enable automatic answering after specified number of rings.

Notes:

• This command works for MT data and fax calls.

• Autoanswering of CSD data and fax calls is supported on ASC0/Mux1 only.

• If <n> is set to higher values, the calling party may hang up before the call is automatically answered.

• The correlation between ATS7 and ATS0 is important. Example: Call setup may fail if ATS7=30 and ATS0=20.

• Setting is local to the interface. It is allowed to have different settings on different interfaces. In such cases the interface ‘wins’, which is idle and uses the smallest <n> value.

• The ATS0 write command is PIN protected.

• The command ATS0 is also used as GPRS compatibility command to answer automatically to a network request for PDP context activation (for details see ATS0 for GPRS). So using ATS0=<n> with n > 0, will perform a GPRS attach, if the ME is not already GPRS attached and if ME is configured to do so (see AT^SCFG, parameter

<gs0aa>). If the GPRS attach fails (e.g., the network rejects the attach request), the write command returns an error, though the new value takes effect.

The GPRS attach will not be performed on recalling a stored user profile with ATZ or on powerup, if a n > 0 setting was stored in the user profile with AT&W.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 81

Chapter 7 – Call-Related Commands

7.13 ATS6 Set Pause before Blind Dialing

Description: No effect for GSM.

Read Command Syntas: ATS6?

Response(s): <n>

OK

Write Command Syntas: ATS6=<n>

Response(s): OK

ERROR

Parameter Description:

<n>

000 – 255 Default is 000

7.14 ATS7 Set Number of Seconds to Wait for

Connection Completion

Description: ATS7 specifies the number of seconds the TA will wait for the completion of the call setup when answering or originating a data call. Also referred to as “no answer timeout”. To put it plainly, this is the time to wait for the carrier signal. If no carrier signal is received within the specified time, the TA hangs up.

Read Command Syntax: ATS7?

Response(s): <n>

OK

Write Command Syntax: ATS7=<n>

Response(s): OK

ERROR

Parameter Description:

<n>

Number of seconds to wait for connection completion 000...060 (Default is 060)

Notes:

• Command ATS7 is applicable only to data calls.

• Values greater than 60 (maximum 255) cause no error, but <n> will be restored to the maximum value of 60.

• The correlation between ATS7 and ATS0 is important. If the called party has specified a high value for

ATS0=<n>, call setup may fail.

Example: Call setup may fail if ATS7=30 and ATS0=20.

7.15 ATS8 Set Number of Seconds to Wait for

Comma Dialing Modifier

Description: No effect for GSM. This command specifies the amount of time, in seconds, that the DCE shall pause, during signaling of call addressing information to the network (dialing), when a “,” (comma) dial modifier is encountered in a dial string.

Read Command Syntax: ATS8?

Response: <n>

OK

Write Command Syntax: ATS8=<n>

Response: OK

ERROR

Parameter Description:

<n>

0

1...255

DCE does not pause when “,” encountered in dial string. Default.

Number of seconds to pause

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 82

Chapter 7 – Call-Related Commands

7.16 ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier

Description: This parameter setting determines the amount of time, that the TA remains connected in absence of a data carrier.

If the data carrier is detected before disconnect, the TA remains connected.

Read Command Syntax: ATS10?

Response: <n>

OK

Write Command Syntax: ATS10=<n>

Response: OK

ERROR

Parameter Description:

<n> number of tenths of seconds of delay

001 - 254 Default is 2.

7.17

ATO Switch from Command Mode to Data

Mode / PPP Online Mode

Description: ATO is the corresponding command to the +++ escape sequence: When you have established a CSD call or a GPRS connection and TA is in command mode, ATO causes the TA to resume the data or GPRS connection and takes you back to data mode or PPP online mode.

Exec Command Syntax: ATO[<n>]

Response: If connection is not successfully resumed:

NO

or

TA returns to data mode from command mode

CONNECT

Note: <text> output only if ATX parameter setting with value > 0.

Parameter Description:

<n>

0 Switch from command mode to data mode. Default.

7.18 +++ Switch from Data Mode to Command

Mode

Description: This command is only available during a CSD call or a GPRS connection. The +++ character sequence causes the TA to cancel the data flow over the AT interface and switch to command mode. This allows you to enter AT commands while maintaining the data connection to the remote device or, accordingly, the GPRS connection.

To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded and followed by a pause of at least 1000 ms. The +++ characters must be entered in quick succession, all within 1000 ms.

Exec Command Syntax: +++

Response: OK

Notes:

• To return from command mode to data or PPP online mode: Enter ATO.

• In Multiplex mode the +++ sequence does not work. Therefore, if required in Multiplex mode, the escape sequence needs to be implemented in the customer’s external Multiplex application. Design solutions, for example using the DTR signal or a modem status command (MSC), can be found in [5], Section “Escape

Sequence”. See also Section 4.10, AT+CMUX.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 83

Chapter 7 – Call-Related Commands

7.19 AT+CBST Select Bearer Service Type

Description: The AT+CBST write command selects the bearer service <name>, the data rate <speed> and the connection element <ce> to be used when data calls are originated. The settings also apply to mobile terminated data calls, especially when single numbering scheme calls or calls from analog devices are received (see AT+CSNS). See GSM 02.02[1] for a list of allowed combinations of subparameters.

Test Command Syntax: AT+CBST=?

Response(s): +CBST: (list of supported<speed>s), (list of supported<name>s), (list of supported<ce>s)

OK

Read Command Syntax: AT+CBST?

Response(s): +CBST: <speed>, <name>, <ce>

OK

Write Command Syntax: AT+CBST=<speed>[, <name>[, <ce>]]

Response(s): OK, ERROR

Parameter Descriptions:

<speed>

0

1

2

4

6

7

Autobauding

300 bps (V.21)

1200 bps (V.22)

2400 bps (V.22bis)

4800 bps (V.32)

9600 bps (V.32) Default

14 14400 bps (V.34)

65 300 bps (V.110)

66 1200 bps (v.110)

68 2400 bps (V.110)

70 4800 bps (V.110)

71 9600 bps (V.110)

75 14400 bps (V.110)

<name>

0

<ce>

Asynchronous modem. Default

Transparent mode is not supported.

Default

7.20 AT+CRLP Select Radio Link Protocol

Parameters for Originated Non-Transparent Data

Calls

Description: The AT+CRLP write command sets radio link protocol (RLP) parameters used when nontransparent data calls are originated. The read command returns the current settings for the supported RLP version 0.

Test Command Syntax: AT+CRLP=?

Response(s): +CRLP: (list of supported<iws>s), (list of supported<mws>s), (list of supported<T1>s), (list of supported<N2>s)

OK

Read Command Syntax: AT+CRLP?

Response(s): +CRLP: <iws>, <mws>, <T1>, <N2>

OK

Write Command Syntax: AT+CRLP=[<iws>[, <mws>[, <T1>[, <N2>]]]]

Response(s): OK, ERROR, +CME ERROR: <err>

Parameter Descriptions:

<iws>

Interworking window size (IWF to MS)

0...61 Default is 61

<mws>

Mobile window size (MS to IWF)

0...61 Default is 61

<T1>

Acknowledgement timer (T1 in 10 ms units)

48 - 255 Default is 78

<N2>

Re-transmission attempts N2

1...255 Default is 6

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 84

Chapter 7 – Call-Related Commands

7.21 AT+CLCC List Current Calls of ME

Description: The execute command returns a list of current calls of ME. If command is successful, but no calls are available, no information response is sent to TE.

Test Command Syntax: AT+CLCC=?

Response: OK

Exec Command Syntax: AT+CLCC

Response: [+CLCC: <idx>, <dir>, <stat>, <mode>, <mpty>[, <number>, <type>[, <alpha>]]]

[+CLCC: <idx>, <dir>, <stat>, <mode>, <mpty>[, <number>, <type>[, <alpha>]]]

[+CLCC:

OK

ERROR

ERROR

Parameter Descriptions:

<idx>

Call identification number as described in GSM02.30 subclause 4.5.5.1; this number can be used in AT+CHLD command operations.

<dir>

0

1

Mobile originated call (MOC)

Mobile terminated call (MTC)

<stat>

State of the call

0

1

2

3

Active

Held

Dialing (MOC)

Alerting (MOC)

4

5

Incoming (MTC)

Waiting (MTC)

<mode>

Bearer/teleservice

0 Voice

1 Data

2 Fax

3 Voice followed by data, voice mode (only in connection with single numbering scheme AT+CSNS)

4 Alternating voice/data, voice mode (only in connection with single numbering scheme AT+CSNS)

5 Alternating voice/fax, voice mode (only in connection with single numbering scheme AT+CSNS)

6 Voice followed by data, data mode (only in connection with single numbering scheme AT+CSNS)

7 Alternating voice/data, data mode (only in connection with single numbering scheme AT+CSNS)

8 Alternating voice/fax, fax mode (only in connection with single numbering scheme AT+CSNS)

9 Unknown

<mpty>

0 Call is not one of multiparty (conference) call parties

1 Call is one of multiparty (conference) call parties

<number>

Phone number in format specified by <type>

<type>

Type of address octect

145 Dialing string <number> includes international access code character ‘+’

129 Otherwise

<alpha>

Alphanumeric representation of <number> corresponding to the entry found in phonebook; used character set should be the one selected with command AT+CSCS (Select TE Character Set).

The maximum displayed length of <alpha> is 16 characters. If <alpha> has more than 16 characters, only the first 15 characters are displayed. To indicate an overflow, a special character will be used as the 16 th character.

This is a space if the character set selected with AT+CSCS is ‘GSM’, or ‘E400’ if the character set is ‘UCS2’.

Due to time constraints on the necessary evaluation of the phonebook, this parameter may show a default value in early call phases (e.g., for <stat>= “dialing”, “incoming” or “alerting”), even if a phonebook entry is present for the number concerned.

Note:

Teleservices other than voice, data, fax are not fully supported by ME. They are used only in connection with the handling for AT+CSNS, and may therefore occur in parameter <mode> for mobile terminated calls.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 85

Chapter 7 – Call-Related Commands

7.22 AT^SLCC List Current Calls of ME

Description: AT^SLCC covers essentially the same information as AT+CLCC, with the following additions:

• The execute command response contains an additional parameter <traffic channel assigned> indicating whether the call has been assigned a traffic channel by the network (transmission of data or inband information is possible).

• The additional write command allows to activate Event reporting for the list of current calls. If event reporting is active for an interface, a call status transition (see Call Status Information) and (if desired) the assignment of a traffic channel will generate an event report indication to this interface. In order to receive this event report as an URC, the URC presentation mode for this interface has to be configured with AT+CMER.

The frequency of event report generation can be configured with AT command AT^SCFG.

Refer to Call Status Information for further detail on the configuration options.

Command Description:

The additional read command allows to determine the event reporting mode <n> which indicates whether the interface receives event report indications for the list of current calls. Mind that the

URC will be displayed only if the URC presentation mode for the interface concerned has been configured with AT+CMER.The read command returns an indication whether event reporting is active for the current interface.

The exec command returns a list of current calls of ME. If command is successful, but no calls are available, no information response is sent to TE.

Use the write command to activate or deactivate event reporting for URC "^SLCC". Event reporting can be enabled separately for each interface. Interface settings are saved with AT&W and can be displayed with AT&V.

Test Command Syntax: AT^SLCC=?

Response: ^SLCC: (list of supported<n>s)

OK

Read Command Syntax: AT^SLCC?

Response: ^SLCC: <n>

OK

Exec Command Syntax: AT^SLCC

Response: [^SLCC:<idx>, <dir>, <stat>, <mode>, <mpty>, <traffic channel assigned>[,

<number>,<type>[, <alpha>]]]

[^SLCC:<idx>, <dir>, <stat>, <mode>, <mpty>, <traffic channel assigned>[,

<number>,<type>[, <alpha>]]]

[^SLCC:...]

OK

ERROR

ERROR

Write Command Syntax: AT^SLCC=[<n>]

Response: OK

ERROR

+CME ERROR: <err>

Unsolicited Result Code: Unsolicited Call Status information if the list of current calls is empty:

^SLCC: if one or more calls are currently in the list:

^SLCC: <idx>, <dir>, <stat>, <mode>, <mpty>, <traffic channel assigned>[,

<number>, <type>[, <alpha>]]

[^SLCC: <idx>, <dir>, <stat>, <mode>, <mpty>, <traffic channel assigned>[,

<number>, <type>[, <alpha>]]]

[... ]

^SLCC:

URC “^SLCC” displays the list of current calls as displayed with the execute command

AT^SLCC. The list is displayed in the state it has at the time of display, not in the state it had when the signal was generated.

The URC’s occurrence indicates call status changes for any of the calls in the list of current calls.

Please refer to Call Status Information and AT^SCFG for further information about the configuration of this URC.

Event reporting can be enabled separately for each interface. Interface settings are saved with AT&W and can be displayed with AT&V. Additionally, The URC presentation mode for the interface must be configured with AT+CMER.

Depending on the value of AT^SCFG setting <sucs>, Indicator “^SLCC” will be issued (if configured with write command AT^SLCC and AT+CMER):

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 86

Chapter 7 – Call-Related Commands

• when a state transition ends in state “active” or in state “unknown” (if AT^SCFG setting <sucs>=”restricted”)

• when any state transition (including transitions beginning or ending in state

“unknown”) occurs in the list of active calls, or when a traffic channel is established (if AT^SCFG setting <sucs>=”verbose”).

If multiple displays of identical list configurations occur, this happens because of short intermediate states of the list, that have already been overridden by new transitions and states. Thus, it is guaranteed that the configuration displayed is always the current configuration at the time of the last display.

The list of active calls displayed with this URC will always be terminated with an empty line preceded by prefix “^SLCC: “, in order to indicate the end of the list.

Parameter Descriptions:

<idx>

This number can be used in AT+CHLD command operations

<n>

0

1 presentation of URC “^SLCC” disabled. Default. presentation of URC “^SLCC” enabled

<dir>

0

1

<stat> mobile originated call (MOC) obile terminated call (MTC) state of the call

0

1 active held

2

3

4

5 dialing (MOC) alerting (MOC) incoming (MTC) waiting (MTC)

6

7 terminating: The call is not active anymore, but inband information is still available. dropped: The call has been suspended by the network, but may be resumed later.

<mode> bearer/teleservice

0 voice

1

2

3 data fax voice followed by data, voice mode (only in connection with single numbering scheme AT+CSNS)

4

5

6

7 alternating voice/data, voice mode (only in connection with single numbering scheme AT+CSNS) alternating voice/fax, voice mode (only in connection with single numbering scheme AT+CSNS) voice followed by data, data mode (only in connection with single numbering scheme AT+CSNS) alternating voice/data, data mode (only in connection with single numbering scheme AT+CSNS)

8

9 alternating voice/fax, fax mode (only in connection with single numbering scheme AT+CSNS) unknown

<mpty>

0 call is not one of multiparty (conference) call parties

1 call is one of multiparty (conference) call parties

<traffic channel assigned>

0 No traffic channel is available to the call

1 mobile has been assigned a traffic channel. It is now possible to send or receive inband information; e.g., to send DTMF tones (cf. AT+VTS) or to receive network announcements.

<number> phone number in format specified by <type>

<type> type of address octect

145 dialing string <number> includes international access code character ‘+’

129 otherwise

<alpha>

Alphanumeric representation of <number> corresponding to the entry found in phonebook; used character set should be the one selected with command AT+CSCS (Select TE Character Set).

The maximum displayed length of <alpha> is 16 characters. If <alpha> has more than 16 characters, only the first 15 characters will be displayed. To indicate an overflow, a special character will be used as the 16 th character. This will be a space if the character set selected with AT+CSCS is ‘GSM’, or ‘E400’ if the character set is ‘UCS2’.

Due to time constraints on the necessary evaluation of the phonebook, this parameter may show a default value during early call phases (e.g., for <stat>= “dialing”, “incoming” or “alerting”), even if a phonebook entry is present for the number concerned.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 87

Chapter 7 – Call-Related Commands

Notes:

• Teleservices other than voice, data, fax are not fully supported by ME. They are used only in connection with the handling for AT+CSNS, and may therefore occur in parameter <mode> for mobile terminated calls.

• If a URC “^SLCC” in verbose mode (see AT^SCFG) has been buffered while the interface was in dedicated mode (depending on the settings of AT+CMER parameter <bfr>), each buffered event indicator will be output as a separate URC after the interface returns to idle mode.

• However, the output will deliver the list of current calls in the “current” state (at the time when the output is generated), possibly leading to multiple displays of identical list configurations.

• Some parameters of AT command AT+CHLD, as well as some situations where the call status in the network changes very quickly (e.g., the transition between <stat>= “unknown”, “dialing” and “alerting” for a call to a reachable subscriber within the registered network) may lead to quasi-simultaneous changes to the states of one or several calls in the list, possibly leading to multiple displays of identical list configurations.

• If multiple displays of identical list configurations occur, this happens because of intermediate states of the list, that have already been overridden by new transitions and states. Thus, it is guaranteed that the configuration displayed in such cases is the current configuration at the time of the last display.

• It is adviseable to receive URC “^SLCC” on an interface that is not used for call initiation, if verbose output is configured. If only voice calls are expected, a setting of AT^SM20= 0 may be used alternatively in order to keep the call from blocking the interface.

Examples

Example 1

^SYSSTART at+cpin=9999

OK

+CREG: 2

+CREG: 1,”0145”,”0016” at^sm20=0

We are now registered command “ATD” for an outgoing voice call will terminate immediately with response “OK”

OK atd”1234567”;

OK

^SLCC:

1,0,2,0,0,0,”1234567”,129,”Called Party”

^SLCC:

^SLCC:

1,0,2,0,0,1,”1234567”,129,”Called Party”

^SLCC:

^SLCC:

1,0,3,0,0,1,”1234567”,129,”Called Party”

^SLCC:

^SLCC:

1,0,0,0,0,1,”1234567”,129,”Called Party”

^SLCC: atd23456;

OK

^SLCC:

1,0,1,0,0,0,”1234567”,129,”Called Party”

^SLCC: 2,0,2,0,0,1,”23456”,129

^SLCC:

^SLCC:

^SLCC: 2,0,2,0,0,1,”23456”,129

^SLCC:

^SLCC:

1,0,1,0,0,0,”1234567”,129,”Called Party”

^SLCC: 2,0,3,0,0,1,”23456”,129

^SLCC:

^SLCC:

1,0,0,0,0,1,”1234567”,129,”Called Party”

^SLCC:

NO CARRIER

^SLCC:

NO CARRIER

We start a voice call.

“OK” response is issued immediately because of setting “^SM20=0”

MO call starts, paging B-party

End of current list

Traffic channel established, network may now transmit network announcements,

ME may now transmit DTMF tones.

End of current list

Call is now ringing at B-Party

End of current list

B-Party has accepted the call, connection established

End of current list

We start a second voice call.

“OK” response issued immediately because another call is already active ( ATD )

The active call is automatically put on hold, triggering the display of the list

The second call has already started before the indication for the held call could be displayed

End of current list

Identical list is displayed again, triggered by the start of the second voice call

Status of the second list entry has already been displayed with the previous URC

End of current list

The held call doesn’t change status right now

The second call is now alerting the B-Party

End of current list

The held call doesn’t change status right now

End of current list: the B-Party of the second call has not accepted the call in time, the second call has ended.

The second call has ended list is now empty: B-Party has ended the first call

The first call has ended

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 88

Chapter 7 – Call-Related Commands

Example 2

^SLCC: 1,1,4,0,0,1,”1234567”,129

^SLCC:

RING

^SLCC: 1,1,4,0,0,1,”1234567”,129

^SLCC:

RING ata

OK

^SLCC: 1,1,0,0,0,1,”1234567”,129

^SLCC: ath

OK

^SLCC:

Incoming call is signaled. Display is triggered by the incoming call, but the current status of the call at the time of display already comprises an active traffic channel.

End of current list

Incoming call is signaled.

The incoming call had a traffic channel assigned from the start.

This second identical display is triggered by the traffic channel assignment.

Since the traffic channel was already indicated in the previous URC, both instances of the URC contain identical information.

End of current list

Incoming call is signaled.

Incoming call is accepted.

Call is established.

The call is now active.

End of current list

Hang up the call.

Hang up complete.

The list of current calls is empty again

7.23 AT+CR Service Reporting Control

Description: AT+CR configures the TA whether or not to transmit an intermediate result code +CR:

<serv> to TE when a call is being set up.

Setting the value of <mode> to 1 may lead to connection failure, if the application (e.g.,

WinFax) waits for default result code/URC.

Test Command Syntax: AT+CR=?

Response: +CR: (list of supported<mode>s)

OK

ERROR

Read Command Syntax: AT+CR?

Response: +CR: <mode>

OK

ERROR

Write Command Syntax: AT+CR=<mode>

Response: OK

ERROR

Parameter Descriptions:

<mode>

0 Disable.

1 Enable

<serv>

“REL ASYNC“ Asynchronous non-transparent

“GPRS“ GPRS

Intermediate Result Code:

If enabled, an intermediate result code is transmitted during connect negotiation when the TA has determined the speed and quality of service to be used, before any error control or data compression reports are transmitted, and before any final result code (e.g., CONNECT) appears.

+CR: <serv>

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 89

Chapter 7 – Call-Related Commands

7.24 AT+CRC Set Cellular Result Codes for

Incoming Call Indication

Description: The AT+CRC command controls whether or not to use the extended format of incoming call indication.

<mode>=1 may lead to a connection failure if the application (e.g., WinFax) waits for the default URC.

Test Command Syntax: AT+CRC=?

Response: +CRC: (list of supported<mode>s)

OK

ERROR

Read Command Syntax: AT+CRC?

Response: +CRC: <mode>

OK

ERROR

Write Command Syntax: AT+CRC=[<mode>]

Response: OK

ERROR

Parameter Descriptions:

<mode>

0 Disable extended format. Default.

1

<type>

Enable extended format

“REL ASYNC“ Asynchronous non-transparent

“FAX“

“VOICE“

“GPRS“

Facsimile

Voice

<PDP_type>, <PDP_addr> [,[<L2P>][,<APN>]] GPRS network request for PDP context activation

Unsolicited Result Codes:

URC 1

RING

Indicates incoming call to the TE if <mode>=0.

URC 2

+CRING: <type>

Indicates incoming call to the TE if <mode>=1.

7.25 AT+CSNS Single Numbering Scheme

Description: The AT+CSNS command enables the ME to accept incoming calls when no bearer capability information is provided with the call; e.g., single numbering scheme calls or calls originitating from analog devices.

Test Command Syntax: AT+CSNS=?

Response: +CSNS: (list of supported<mode>s)

OK

Read Command Syntax: AT+CSNS?

Response: +CSNS: <mode>

OK

Write Command Syntax: AT+CSNS=[<mode>]

Response: OK

ERROR

+CME ERROR

Parameter Description:

<mode>(num)

0

2

Voice: Each call received without bearer element is assumed to be speech. Default.

Fax: Each call received without bearer element is assumed to be an incoming fax.

4 Data: Each call received without bearer element is assumed to be a data call.

Please take into account that the bearer service parameters set with AT+CBST apply to all data calls including those received without bearer capability.

Notes:

• The command must be set before the call comes. By default, when you do not modify the settings, all calls received without bearer element are assumed to be voice.

• The setting will be automatically saved when you power down the GSM engine with AT^SMSO, provided that

PIN authentication has been done. This value will be restored when PIN authentication is done again.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 90

Chapter 7 – Call-Related Commands

7.26

AT^SCNI List Call Number Information

Description: TA returns a list of current calls of ME.

Test Command Syntax: AT^SCNI=?

Response: OK

Exec Command Syntax: AT^SCNI

Response: ^SCNI: <id>1[,<cs>[,<number>,<type>]]

<id>2[,<cs>[,<number>,<type>]]

[...]

OK

ERROR

Parameter Descriptions:

+CME ERROR: <err>

<id>

Call identification number; this number can be used in AT+CHLD command operations.

1...7

<cs>

Call status of respective call number (first parameter)

0 call hold call in progress waiting call

1

2

<number> string type phone number in format specified by <type>

<type> type of address octet in integer format; 145 when dialing string includes international access code character “+”; otherwise 129

Note: See also AT+CLCC

7.27 AT^SLCD Display Last Call Duration

Description: TA returns last call duration or current call duration.

Test Command Syntax: AT^SLCD=?

Response: OK

ERROR

ERROR

Exec Command Syntax: AT^SLCD

Response: ^SLCD: <time>

OK

ERROR

ERROR

Parameter Description:

<time>

Format is “hh:mm:ss”, where characters indicate hours, minutes, seconds; e.g., 22:10:00 “22:10:00”

Max value is 9999:59:59

Note: The proper working of that command is network dependent.

7.28 AT^STCD Display Total Call Duration

Description: TA returns total call duration (accumulated duration of all calls).

Test Command Syntax: AT^STCD=?

Response: OK

ERROR

ERROR

Exec Command Syntax: AT^STCD

Response: ^STCD: <time>

OK

ERROR

ERROR

Parameter Description:

<time>

Format is “hh:mm:ss”, where characters indicate hours, minutes, seconds; e.g., 22:10:00 “22:10:00”

Max value is 9999:59:59

Notes:

• The Total Call Duration will not be reset by power off or other means.

• The proper working of that command is network dependant and only for MO calls.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 91

7.29 ATP Select Pulse Dialing

Exec Command Syntax: ATP

Response: OK

Note: No effect for GSM.

7.30 ATT Select Tone Dialing

Exec Command:

Response:

Note: No effect for GSM.

ATT

OK

Chapter 7 – Call-Related Commands

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 92

Chapter 8 – Network Service Commands

Chapter 8. Network Service

Commands

The AT Commands described in this chapter are related to various network services. More commands related to this area can be found in Chapter 9., Supplementary Service Commands.

8.1 AT+COPN Read Operator Names

Description: The AT+COPN command returns the list of operator names from the ME. Each operator code <numericn> that has an alphanumeric equivalent <alphan> in the ME memory is returned. See also: AT^SPLM.

Test Command Syntax: AT+COPN=?

Response: OK

ERROR

ERROR

Exec Command Syntax: AT+COPN

Response: +COPN: <numericn>, <alphan>

+COPN:

OK

ERROR

ERROR

Parameter Descriptions:

<numericn>

Operator in numeric format; GSM location area identification number.

<alphan>

Operator in long alphanumeric format; can contain up to 16 characters.

8.2 AT+COPS Operator Selection

Description: AT+COPS queries the present status of the Multi-Tech wireless modem’s network registration and allows to determine whether automatic or manual network selection shall be used.

Additional service is available with AT^SOPS.

Three operator selection modes are available:

• Automatic

The Multi-Tech wireless modem searches for the home operator automatically. If successful the Multi-Tech wireless modem registers to the home network.

If the home network is not found, the Multi-Tech wireless modem goes on searching. If a permitted operator is found, the Multi-Tech wireless modem registers to this operator.

If no operator is found the Multi-Tech wireless modem remains unregistered.

• Manual

Desired operator can be determined using the AT+COPS write command. If the operator is found, the Multi-Tech wireless modem registers to it immediately. If the selected operator is forbidden, the Multi-Tech wireless modem remains unregistered.

• Manual/automatic

The ME first tries to find the operator determined via AT+COPS write command. If it is able to register to this operator, it enters the manual operator selection mode. If the ME cannot find this operator or fails to register to this operator, then it enters the automatic operator selection mode and starts to select the home operators network or another (permitted) one.

The most recently entered operator selection mode is still valid after the ME was restarted.

(power-off/on).

The AT+COPS test command lists sets of four parameters, each representing an operator present in the network.

A set consists of

• an integer indicating the availability of the operator,

• long alphanumeric format of the operator’s name and

• numeric format representation of the operator.

Any of the parameters may be unavailable and will then be an empty field (,,).

The list of operators comes in the following order: Home network, networks referenced in SIM and other networks. The operator list is followed by a list of the supported <mode>s and

<format>s. These lists are delimited from the operator list by two commas.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 93

Chapter 8 – Network Service Commands

If the test command is used during an ongoing GPRS transfer, traffic will be interrupted for up to one minute.

The AT+COPS read command returns the current <mode> and the currently selected operator. If no operator is selected, <format> and <oper> are omitted.

The AT+COPS write command forces an attempt to select and register to the GSM network operator (see note below). If the selected operator is not available, no other operator will be selected (except <mode>=4). The selected operator name <format> will apply to further read commands, too.

Test Command Syntax: AT+COPS=?

Response: +COPS: [list of present operators (<opStatus>, long alphanumeric <oper>s,,numeric

<oper>s ], , (list of supported <mode>s), (list of supported <format>s)

OK

ERROR

+CME ERROR: <err>

Read Command Syntax: AT+COPS?

Response:

Response:

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+COPS=<mode>[, <format>[, <oper>]]

OK

ERROR

Parameter Descriptions:

+CME ERROR: <err>

<opStatus>

Status

0

1

2

3

<oper>

Operator

Unknown

Operator available

Current operator

Operator forbidden

If test command: Operator name in long alphanumeric format and numeric format.

If read command: Operator name as per <format>.

If write command: Operator name in numeric format.

<mode>

Parameter values 0 and 1 are stored non-volatile in the Multi-Tech wireless modem.

0

1

Automatic mode; <oper> field is ignored. Default.

Manual operator selection

Write command requires <oper> in numeric format; i.e., <format> shall be 2.

Read command returns the current <mode> and the currently selected <oper>. If no operator is

2

3

4

<format> selected, <format> and <oper> are omitted.

Manually deregister from network and remain unregistered until <mode>=0 or 1 or 4 is selected.

Set only <format> (for AT+COPS read command).

Automatic / manual selection; if manual selection fails, automatic mode (<mode>=0) is entered

(<oper> field will be present).

0

2

Long alphanumeric format of <oper>. Can be up to 16 characters long. Default.

Numeric format of <oper>. This is the GSM Location Area Identification (LAI) number, which consists of the 3-digit Mobile Country Code (MCC) plus the 2- or 3-digit Mobile Network Code

(MNC).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 94

Chapter 8 – Network Service Commands

8.3 AT^SOPS Extended Operator Selection

Description: AT^SOPS queries the present status of the Multi-Tech wireless modem’s network registration.

Since basic operator selection services are available with AT+COPS this command uses the methods of the Enhanced Operator Name String (EONS) specification while handling operator name strings. Additional EONS related information is available with AT^SIND.

AT^SOPS test command lists sets of five parameters, each representing an operator present in the network.

A set consists of:

1. an integer indicating the availability of the operator,

2. specification of the source of the operator name <eonsOperator>,

3. operator name according to EONS Table,

4. Service Provider Name from the SIM Service Table and

5. numeric format representation of the operator.

Any of the parameters may be unavailable and will then be an empty field (,,).

The list of operators comes in the following order: Home network, networks referenced in SIM and other networks.

After the operator list the Multi-Tech wireless modem returns lists of supported <mode>s and

<format>s. These lists are delimited from the operator list by two commas.

If the test command is used while an ongoing GPRS transfer, traffic will be interrupted for up to one minute.

Test CommandSyntax: AT^SOPS=?

Response: ^SOPS:[list of present operator( <opStatus>, <eonsType>, <eonsOperator>,

<servProvider>, <opName>)s ], , (list of supported <mode>)s, (list of supported

<format>)s

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<opStatus>

Status

0

1

2

3

<eonsType> unknown operator available current operator operator forbidden

Specification of the source of the operator name <eonsOperator>. Details of EONS-supplied operator name types are available at AT^SIND.

<eonsOperator>

Operator name; format depends on the source of the operator name, specified by <eonsType>.

<servProvider>

Service Provider Name according to setting of Service No. 17 in the SIM Service Table (EFSST).

<opName>

Operator Operator name in numerical presentation contains the GSM Location Area Identification (LAI) number, which consists of the 3-digit Mobile Country Code (MCC) plus the 2- or 3-digit Mobile Network Code (MNC).

Parameter is stored non-volatile to the SIM.

<mode>

Parameter is not applicable.

<format>

Parameter is not applicable.

Note: The AT^SOPS Test command is only accepted by the module after a valid pin has been entered.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 95

Chapter 8 – Network Service Commands

8.4 AT+CREG Network Registration

Description: The AT+CREG command serves to verify the network registration status of the ME. For this purpose two types of URCs are available.

The AT+CREG read command returns the URC presentation mode <n> and an integer <stat> that shows the registration status of the ME. The location information elements <lac> and <ci> are returned only when <n>=2 and ME is registered to the network.

Test Command Syntax: AT+CREG=?

Response(s): +CREG: (list of supported<n>s)

OK

Read Command Synatx: AT+CREG?

Response(s): +CREG: <n>, <stat>[, <lac>, <ci>]

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CREG=[<n>]

Response(s): OK

ERROR

+CME ERROR: <err>

Unsolicited Result Codes:

URC 1

If <n>=1 and there is a change in the ME network registration status:

+CREG: <stat>

URC 2

If <n>=2 and there is a change in the ME network registration status or a change of the network cell:

+CREG: <stat>[, <lac>, <ci>]

Parameter Descriptions:

<n>

0

1

2

Disable +CREG URC. Default.

Enable URC +CREG:<stat> to report status of network registration

Enable URC +CREG:<stat>[,<lac>,<ci>] to report status of network registration including location information. Optional parameters <lac> and <ci> will not display during calls or if these values have not changed since last AT+CREG read command or since last indication by +CREG URC.

<stat>

0 Not registered. ME is currently not searching for new operator.

Normally, status 0 occurs temporarily between two network search phases (Status 2). However, if it persists, one of the following reasons may apply:

• Automatic network selection is active, but probably there is:

No SIM card available

No PIN entered

No valid Home PLMN entry found on the SIM

• Manual network selection is active, and the selected network is available, but login fails due to one of the following reasons:

#11 ... PLMN not allowed

#12 ... Location area not allowed

#13 ... Roaming not allowed in this location area

In either case, user intervention is required. Yet, emergency calls can be made if any network is available.

1

2

Registered to home network

Not registered, but ME is currently searching for a new operator.

The ME searches for an available network. Failure to log in until after more than a minute may be due to one of the following causes:

• No network available or insufficient Rx level.

• The ME has no access rights to the networks available.

• Networks from the SIM list of allowed networks are around, but login fails due to one of the following reasons:

∗ #11 ... PLMN not allowed

∗ #12 ... Location area not allowed

∗ #13 ... Roaming not allowed in this location area

After this, the search will be resumed (if automatic network search is enabled).

• The Home PLMN or an allowed PLMN is available, but login is rejected by the cell (reasons:

Access Class or LAC).

If at least one network is available, emergency calls can be made.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 96

Chapter 8 – Network Service Commands

3

4

5

Registration denied

• Authentication or registration fails after Location Update Reject due to one of the following:

∗ #2 ... IMSI unknown at HLR

∗ #3 ... Illegal MS

∗ #6 ... Illegal ME

Either the SIM or the MS or the ME are unable to log into any network. No further attempt is made to reach or log into a network. User intervention is required. Emergency calls can be made, if any network is available.

Unknown (not used)

Registered; roaming. The ME is registered at a foreign network (national or international network)

<lac>

Two byte location area code in hexadecimal format (e.g., “00C3” equals 193 in decimal).

<ci>

Two byte cell ID in hexadecimal format.

Example:

AT+CREG=2

OK

AT+COPS=0

OK

+CREG: 2

+CREG: 1,”0145”,”291A”

Activates extended URC mode.

Forces ME to automatically search network operator.

URC reports that ME is currently searching.

URC reports that operator has been found.

8.5 AT+CSQ Signal Quality

Description: The AT+CSQ execute command indicates the received signal strength <rssi> and the channel bit error rate <ber>.

Test Command Syntax: AT+CSQ=?

Response: +CSQ: (list of supported<rssi>s), (list of supported<ber>s)

OK

Exec Command Syntax: AT+CSQ

Response: +CSQ: <rssi>,<ber>

OK

Parameter Descriptions:

<rssi>

0

1

2..30

31

99

-113 dBm or less

-111 dBm

-109... -53 dBm

-51 dBm or greater not known or not detectable

<ber>

0..7

99 as RXQUAL values in the table in GSM 05.08 section 8.2.4. not known or not detectable

Note: After using network related commands such as AT+CCWA, AT+CCFC, AT+CLCK, users are advised to wait

3s before entering AT+CSQ. This is recommended to be sure that any network access required for the preceding command has finished.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 97

Chapter 8 – Network Service Commands

8.6 AT^SMONC Cell Monitoring

Description: The AT^SMONC execute command delivers cell information containing 9 values from a maximum of 7 base stations.

The first base station is the serving cell.

Test Command Syntax: AT^SMONC=?

Response: OK

ERROR

+CME

Response:

ERROR

Exec Command Syntax: AT^SMONC

^SMONC: <MCC>1, <MNC>1, <LAC>1, <cell>1, <BSIC>1, <chann>1, <RSSI>1, <C1>1,

<C2>1, <MCC>2, <MNC>2, <LAC>2, <cell>2, <BSIC>2, <chann>2, <RSSI>2, <C1>2,

<C2>2, ...

OK

ERROR

ERROR

Parameter Descriptions:

<MCC>

Mobile country code

3 digits; e.g., 232

000

<MNC>

Mobile network code

2 digits or 3 digits; e.g., 07 or 003

000

<LAC>

Location area code

4 hexadecimal digits; e.g., 4EED

0000

<cell>

Cell identifier

Not decoded

Not decoded

Not decoded

4 hexadecimal digits; e.g., 4EAF

0000

<BSIC>

Base station identity code

Not decoded

2 digits; e.g., 32

00 Not decoded

<chann>

ARFCN (Absolute Frequency Channel Number)

0 Not decoded. In this case, all remaining parameters related to the same channel are neither decoded. For example, a non-existing cell appears as follows:

000,000,0000,0000,00,0,0,-,-

<RSSI>

Received signal level of the BCCH carrier (0..63). The indicated value is composed of the measured value in dBm plus an offset. This is in accordance with a formula specified in 3GPP TS 05.08

<C1>

Coefficient for base station reselection; e.g., 30. In dedicated mode, under certain conditions the parameter cannot be updated. In such cases a ‘-‘ is presented.

<C2>

Coefficient for base station reselection; e.g., 30. In dedicated mode, under certain conditions the parameter cannot be updated. In such cases a ‘-‘ is presented.

Note: To some extent, the cell monitoring commands AT^MONI, AT^MONP and AT^SMONC cover the same parameters. The receiving level, for example, can be queried with all three commands. Yet the resulting values may be slightly different, even though obtained over a time period of a few seconds. This is quite normal and nothing to worry about, as the cell information is permanently updated.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 98

Chapter 8 – Network Service Commands

8.7 AT^SMOND Cell Monitoring

Description: The AT^SMOND execute command can be used to obtain status information of the service cell and up to six neighbor cells. The advantage over other cell monitoring commands is that

AT^SMOND delivers more detailed information about the received signal strength.

Test Command: AT^SMOND=?

Response(s): OK, ERROR, +CME ERROR

Exec Command: AT^SMOND

Response(s): ^SMOND: [<sci>][, <nci>][, <TA>][, <rssiber>]

OK, ERROR, +CME ERROR

Parameter Description:

<sci>

Serving cell information (comma-separated, no cr/lf included)

<MCC>,<MNC>,<LAC>,<cell>,<BSIC>,<chann>,<RxLev>,<RxLev>Full,<RxLev>Sub,<RxQual>,<RxQual>Full,<

RxQual>Sub,<Timeslot>

If no serving cell is found, unavailable values are omitted:” ,,,,,,<RxLev>,,,0,,,0”

<nci>

Neighbor cell information for neighbor cell 1 through 6 (comma-separated, no cr/lf included)

<MCC>1,<MNC>1,<LAC>1,<cell>1,<BSIC>1,<chann>1,<RxLev>1, (these parameters repeated for neighbor cells 2 through 6 with no CR/LF): ... <MCC>6,<MNC>6,<LAC>6,<cell>6,<BSIC>6,<chann>6,<RxLev>6

An unavailable cell appears as follows: “ ,,,,,,0”

<rssiber>

Values for RSSI and BER (comma-separated, no cr/lf included)

<RSSI>,<BER>

<MCC>

Mobile country code

3 digits, e.g. 232

000 Not decoded

<MNC>

Mobile network code

2 digits or 3 digits, e.g. 07 or 003

000

<LAC>

Location area code

4 hexadecimal digits, e.g. 4EED

0000

<cell>

Cell identifier

4 hexadecimal digits, e.g. 4EAF

0000

<BSIC>

Base station identity code

2 digits, e.g. 32

00

Not decoded

Not decoded

Not decoded

Not decoded

<chann>

ARFCN (Absolute Frequency Channel Number)

<RxLev>

Received signal level in dBm

<RxQual>

Received signal quality as defined in GSM05.08

<Timeslot>

Assigned timeslot. If mobile is in idle mode, timeslot 0 (BCCH timeslot) will be indicated.

0...8

<TA>

Assigned timeslot

Timing advance for the serving cell, in bits.

<RSSI>

Receive Level, with value 99 indicateing “not known or not detectable”

0...31 Signifies the RSSI range from -113dBm or less (“0”) to -51dBm or greater (“31”) in steps of -2dBm (e.g. “1” = -111 dBm, “2” = -109 dBm ...,

“30” = - 53dBm)

<BER>

Bit Error rate, with value 99 indicating “not known or not detectable”

0...7 as RXQUAL values RXQUAL0 to RXQUAL7 in GSM 05.08 section 8.2.4

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 99

Chapter 8 – Network Service Commands

Notes

• To some extent, the cell monitoring commands AT^SMOND, AT^MONI, AT^MONP and AT^SMONC cover the same parameters. The receiving level, for example, can be queried with all three commands. Yet the resulting values may be slightly different, even though obtained over a time period of a few seconds. This is quite normal and nothing to worry about, as the cell information is permanently updated.

• During a connection, not all of the neighbour cell information can be decoded. The following restrictions apply:

∗ Information is updated only for neighbour cells that have already been visible at connection setup, and continue to be included in the list of cells.

∗ New neighbour cells added to the list, for example after handover, cannot be displayed until the connection is released.

Example at^smond

^SMOND:262,01,3008,6060,32,100,66,,,0,,,0,

Execute command

Line breaks inserted for readability in print

262,01,3008,DDD1,35,92,80,

262,01,3008,,31,96,83,

262,01,3008,BFBE,35,27,86,

262,01,3008,,32,98,88,

262,01,3008,BB44,32,90,89,

262,01,3008,8307,31,22,93,

2,23,99

8.8 AT^MONI Monitor Idle Mode and Dedicated

Mode

Description:

Test Command:

Response:

The AT^MONI command supplies information of the serving/dedicated cell. There are two ways to retrieve the information: once on request by using the execute command or automatically every <period> seconds by using the write command. To stop the periodic presentation type “AT” or “at”.

AT^MONI=?

^MONI:(list of supported <period>s)

OK

Exec Command:

Response:

Write Command:

Response:

AT^MONI

See: Section 8.8.1, AT^MONI responses

OK

AT^MONI=<period>

See: Section 8.8.1, AT^MONI responses

OK

ERROR

+CME

Parameter Description:

<period>

Display period in seconds

1...254

Notes:

• The two header lines (see Section 8.8.1, AT^MONI responses) are output after every ten data lines.

• The length of following output lines exceeds 80 characters. Therefore a terminal program may draw a carriage return on a screen. However, this is not part of the response.

• The parameters LAC and cell are presented as hexadecimal digits, the remaining parameters are composed of decimal digits.

• If the radio cell changes during a connection, the parameters PWR, RXLev and C1 of the ‘Serving Cell’ part cannot be updated under certain conditions and therefore, are displayed as “-“ (for conditions see also

AT+CREG). This is because the MS does not update the cell selection and reselection parameters since, in this mode, they are not relevant for operation. When the connection ends, and the mobile is back to IDLE mode, correct values will be given.

If the radio cell changes during a connection, it normally takes 1 or 2 seconds to update the parameters cell,

NCC and BCC. Until the information is received from the new base station, the default values will be shown instead: cell=”0000”, NCC=”-“, BCC=”-“.

• If the BS supports frequency hopping during a connection, the dedicated channel (parameter chann) is not stable. This mode is indicated by chann = ‘h’.

• To some extent, the cell monitoring command AT^SMONC covers the same parameters. The receiving level, for example, can be queried with both commands. Yet the resulting values may be slightly different, even though obtained over a time period of a few seconds. This is quite normal and nothing to worry about, as the cell information is permanently updated.

• For compatibility with earlier products and to support legacy applications, any input character may be used to stop the output in certain cases (depending on the settings of AT+IPR and AT+CMUX).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 100

Chapter 8 – Network Service Commands

8.8.1 AT^MONI Responses

ME is not connected: a) ME is camping on a cell and registered to the network:

Serving Cell

chann rs dBm MCC MNC LAC cell NCC BCC PWR RXLev C1

1013 21 -71 001 01 1001 0103 7 7 33 -105 33

I Dedicated channel

I chann TS timAdv PWR dBm Q ChMod

I No connection b) ME is camping on a cell but not registered to the network (only emergency call allowed):

Serving Cell chann rs dBm MCC MNC LAC cell NCC BCC PWR RXLev C1

1013 21 -71 001 01 1001 0103 7 7 33 -105 33

I Dedicated channel

I chann TS timAdv PWR dBm Q ChMod

I Limited Service c) ME camping on a cell, but searching for a better cell (cell reselection):

Serving Cell chann rs dBm MCC MNC LAC cell NCC BCC PWR RXLev C1

I Dedicated channel

I chann TS timAdv PWR dBm Q ChMod

1013 21 -71 001 01 1001 0103 7 7 33 -105 33 I Cell Reselection d) ME is searching and could not (yet) find a suitable cell:

Serving Cell chann rs dBm MCC MNC LAC cell NCC BCC PWR RXLev C1

Searching

I Dedicated channel

I chann TS timAdv PWR dBm Q ChMod

ME is connected (Call in progress):

Serving Cell chann rs dBm MCC MNC LAC cell NCC BCC PWR RXLev C1

1013 19 -76 001 01 1001 0103 7 7 33 -105 33

I Dedicated channel

I chann TS timAdv PWR dBm Q ChMod

I 1015 1 0 5 -76 0 S_HR

Columns for Serving Cell:

Column chann rs

ARFCN (Absolute Frequency Channel Number) of the BCCH carrier

RSSI value 0 - 63 (RSSI = Received signal strength indication) dBm

MCC

MNC

LAC cell

NCC

BCC

Receiving level of the BCCH carrier in dBm

Mobile Country Code (first part of the PLMN code)

Mobile Network Code (second part of the PLMN code)

Location area code, see note below

Cell ID, see note below

PLMN colour code

Base station colour code

PWR maximal power level used on RACH channel in dBm

RXLev minimal receiving level (in dBm) to allow registration

C1 coefficient for base station selection

Columns for Dedicated Channel:

Column Description chann

TS timAdv

PWR dBm

Q

ChMod

ARFCN (Absolute Frequency Channel Number) of the TCH carrier

Note: <chann> = h indicates frequency hopping.

Timeslot number

Timing advance in bits

Current power level

Receiving level of the traffic channel carrier in dBm

Receiving quality (0-7)

Channel mode (S_HR: Half rate, S_FR: Full rate, S_EFR: Enhanced Full Rate)

8.8.2 Service States

Depending on the service state, an additional textual output is generated (refer also to the response examples):

• ‘Searching’ - The MS is searching, but could not (yet) find a suitable cell. This output appears after restart of the

MS or after loss of coverage.

• ‘No connection’ - The MS is camping on a cell and registered to the network. The service state is idle; i.e., there is no connection established or a dedicated channel in use.

• ‘Cell Reselection’ - The MS has not yet lost coverage but is searching for a better cell, since the cell reselection criterion is fulfilled.

• ‘Limited Service’ - The MS is camping on a cell but not registered to the network. Only emergency calls are allowed. The MS enters this state, for example, when

∗ no SIM card is inserted, or PIN has not been given,

∗ neither Home PLMN nor any other allowed PLMN are found,

∗ registration request was not answered or denied by the network (use command AT+CREG to query the registration status),

∗ authentication failed.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 101

Chapter 8 – Network Service Commands

8.9 AT^MONP Monitor Neighbour Cells

Description: The AT^MONP supplies information for up to six neighbor cells. There are two ways to retrieve the information: 1) by request using the execute command or 2) automatically every <period> seconds by using the write command. To stop the periodic presentation type “AT” or “at”.

Test Command Syntax: AT^MONP=?

Response: ^MONP:(list of supported <period>s)

OK

Exec Command Syntax: AT^MONP

Response: See: Section 8.8.1, AT^MONP responses

OK

Write Command Syntax: AT^MONP=<period>

Response: See: Section 8.8.1, AT^MONP responses

OK

ERROR

ERROR

Parameter Description:

<period>

Display period in seconds

1...254

Notes:

• Due to the fact that not all necessary information of the neighbour cells can be decoded during a connection, there are several constraints to be considered:

∗ Only neighbor cells that have already been visible in IDLE mode will be further updated, as long as they are still included in the list.

∗ Though new neighbor cells can be added to the list (e.g., due to handover), their C1 and C2 parameters cannot be displayed until the connection is released. In this case “-“ is presented for C1 and C2.

∗ To some extent, the cell monitoring command AT^SMONC covers the same parameters. The receiving level, for example, can be queried with both commands. Yet the resulting values may be slightly different, even though obtained over a time period of a few seconds. This is quite normal and nothing to worry about, as the cell information is permanently updated.

• For compatibility with earlier products and to support legacy applications, any input character may be used to stop the output in certain cases (depending on the settings of AT+IPR and AT+CMUX).

8.9.1 AT^MONP Responses

Response of AT^MONP (Example): chann rs dBm MCC MNC BCC C1 C2

653 26 -84 262 07 0 22 22

660 20 -90 262 07 3 16 16

687 19 -91 262 07 1 15 15

678 14 -96 262 07 3 10 10

671 14 -96 262 07 1 10 10

643 10 -100 262 07 7 6 6

Column

Chann rs dBm

MCC

MNC

BCC

Description

ARFCN (Absolute Radio Frequency Channel Number) of the BCCH carrier

RSSI value 0 - 63 (RSSI = Received signal strength indication)

Receiving level in dBm

Mobile Country Code (first part of the PLMN code)

Mobile Network Code (second part of the PLMN code)

Base Station colour code

C1

C2 cell selection criterion cell reselection criterion

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 102

Chapter 8 – Network Service Commands

8.10 AT^SMONG GPRS Monitor

Description: The AT^SMONG command supplies GPRS specific cell information. There are two ways to retrieve the information: once on request by using the execute command or automatically every <period> seconds by using the write command. To stop the periodic presentation type “AT” or “at”.

Test Command Syntax: AT^SMONG=?

Response: ^SMONG:(list of supported <table>s), (list of supported <period>s)

OK

ERROR

+CME

Exec Command Syntax: AT^SMONG

Response: GPRS Monitor

Cell Info Table (see: Section 8.10.1, AT^SMONG Cell Info Table)

OK

ERROR

ERROR

Write Command Syntax: AT^SMONG=<table>[, <period>]

Response: ^SMONG: GPRS Monitor

Cell Info Table (see: Section 8.10.1, AT^SMONG Cell Info Table)

OK

ERROR

ERROR

Parameter Descriptions:

<table>

1 Cell Info Table

<period>

Display period in seconds

If <period> is omitted the cell data will be presented only once on a single line (as if Execute command was issued).

If <period> is given, the cell data will be listed repeatedly on 10 data lines. Every 10 th header, simply to repeat the column titles.

data line is followed by the

1...100

Note: For compatibility with earlier products and to support legacy applications, often any input character will stop the periodic output of the write command. But since this applies only in certain cases (depending on the settings of AT+IPR and AT+CMUX), it is recommended to always use “at” or “AT”.

8.10.1 AT^SMONG Cell Info Table

Example output for AT^SMONG:

GPRS Monitor

BCCH G PBCCH PAT MCC MNC NOM TA RAC # Cell #

0637 1 - 4 234 05 2 00 0B

Columns of the cell info table:

MCC

MNC

NOM

TA

RAC

Column

BCCH

G

PBCCH

PAT

Description

ARFCN of BCCH carrier

G GPRS / EDGE status:

0

1

2

3

GPRS / EGPRS not available in currently used cell

GPRS available in currently used cell

GPRS attached

EGPRS available in currently used cell

4

Note: During a voice call or CSD connection, GPRS services are not available; and, consequently,

G=0 is displayed.

If PBCCH is present, indication of ARFCN, else “-“ or if Frequency Hopping is used “H”

Priority Access Threshold (GSM Rec. 04.08 / 10.5.2.37b)

0

1

2

3

Packet access is not allowed in the cell

Spare, shall be interpreted as “000” (packet access not allowed)

Spare, shall be interpreted as “000” (packet access not allowed)

Packet access is allowed for priority level 1

4 Packet access is allowed for priority level 1 to 2

Mobile Country Code

Mobile Network Code

Network Operation Mode (1...3)

Timing Advance Value

Routing Area Code (as hexadecimal value)

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 103

Chapter 8 – Network Service Commands

8.11 AT^SALS Alternate Line Service

Description: The AT^SALS command is designed to support Alternate Line Service. This allows the subscriber to use two voice numbers on the same SIM card (service requires a dual line

SIM card).

The write command enables or disables the presentation of <view> and specifies the

<line> used for outgoing calls. The read command returns the presentation mode of

<view> and the currently selected <line>.

Test Command Syntax: AT^SALS=?

Response: ^SALS:(list of supported <view>s), (list of supported <line>s)

OK

Read Command Syntax: AT^SALS?

Response: ^SALS: <view>, <line>

OK

ERROR

Write Command Syntax: AT^SALS=<view>[, <line>]

Response: OK

ERROR

Parameter Descriptions:

<view>

Controls the presentation mode of the URC “^SALS” which indicates the line number used by an incoming call:

0

1

<line>

Selects the line to be used for outgoing calls.

1

2

Disables indication of the called line. Default.

Enables indication of the called line

ALS Line 1. Default.

ALS Line 2

Unsolicited Result Code:

If switched on with <view>=1:

^SALS: <line>

Indicates the line used by an incoming call. The setting is global for the ME; it is also non-volatile.

Note:

If a non ALS SIM is inserted, the <line> will be reset to line 1 as well.

Example:

AT^SALS=1,1

RING

^SALS: 2

Line 1 has been selected for outgoing calls. “^SALS” URC is enabled.

You receive a notification that you have an incoming call on line 2.

8.12

AT^SHOM Display Homezone

Description: The AT^SHOM returns the homezone state. The result is valid only, if network registration state <stat> is 1 (registered) (see AT+CREG).

The feature is available only for supported network operators (Viag, One2One, Orange and LCI) and requires a suitable SIM card. If the homezone feature is not supported by the network operator or SIM card, result is always 0.

Test Command Syntax: AT^SHOM=?

Response: OK

Exec Command Syntax: AT^SHOM

Response: ^SHOM: <homezonestate>

OK

ERROR

+CME ERROR: <err>

Parameter Description:

<homezonestate>

0

1

ME is out of Homezone

ME is within the Homezone

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 104

Chapter 8 – Network Service Commands

8.13 AT^SPLM Read the PLMN List

Description: The AT^SPLM execute command returns the list of operators from the ME. Each operator code <numeric> that has an alphanumeric equivalent <alpha> in the ME memory is returned. The list is sorted by operator codes. See also AT+COPN, AT+COPS

Test Command Syntax: AT^SPLM=?

Response: OK

If error is related to ME functionality:

ERROR

+CME ERROR: <err>

Exec Command Synatx: AT^SPLM

Response: ^SPLM:<numeric>, long <alpha>

]

OK

If error is related to ME functionality:

ERROR

+CME

Parameter Descriptions:

<numeric>

Operator in numeric form; GSM location area identification number

<alpha>

Operator in long alphanumeric format; can contain up to 16 characters

8.14 AT^CPOL Preferred Operator List

Description: The AT+CPOL read command returns the list of the preferred operators. The AT+CPOL write command allows to edit the list of the preferred operators. If <index> is given but <operator> is left out, the entry is deleted. An operator can be only once in the list.

Test Command: AT+CPOL=?

Response: +CPOL:(list of supported <index>s), (list of supported <format>s)

OK

ERROR

+CME

Read Command: AT+CPOL?

Response: +CPOL: <index>, <format>, <operator>

...

OK

ERROR

ERROR

Write Command: AT+CPOL=<index>[, <format>, <operator>]

Response: OK

ERROR

+CME

Parameter Descriptions:

<index>

The order number of the operator in the SIM preferred operator list.

<format>

2

<operator>

Numeric format

Operator in numeric format (GSM Location Area Identification number which consists of a 3-digit country code plus a 2- or 3-digit network code).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 105

Chapter 8 – Network Service Commands

8.15 AT^SPLR Read Entry from the Preferred

Operators List

Description: The AT^SPLR write command returns used entries from the SIM list of preferred operators with <indexa> between <index1> and <index2>. If <index2> is not given, only entry at

<index1> is returned. The test command returns the whole index range supported by the

SIM.

See also AT+CPOL

Test Command Syntax: AT^SPLR=?

Response: ^SPLR:(list of supported) <indexa>s

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT^SPLR=<index1>[, <index2>]

Response: ^SPLR: <index1><oper>

<index2><oper>

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<index1>

Location number to start reading from

<index2>

Location number where to stop reading

<indexa>

Index range supported by the SIM card (between <index1> and <index2>)

<oper>

Operator in numeric form; GSM location area identification number

8.16 AT^SPLW Write an Entry to the Preferred

Operators List

Description: The AT^SPLW write command writes an entry to the SIM list of preferred operators at location number <index>.

If <index> is given but <oper> is left out, the entry is deleted. An operator can be only once in the list. Test command returns the whole index range supported by the SIM.

See also AT+CPOL

Test Command Syntax: AT^SPLW=?

Response: ^SPLW:(list of supported) <index>s

OK

ERROR

+CME

Write Command Syntax: AT^SPLW=<index>[, <oper>]

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<index> location number

<oper>

Operator in numeric format (GSM Location Area Identification number which consists of a 3-digit country code plus a 2- or 3-digit network code).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 106

Chapter 9 – Supplementary Service Commands

Chapter 9. Supplementary Service

Commands

The AT Commands described in this chapter are related to the Supplementary Services offered by the GSM network.

9.1 AT+CACM Accumulated Call Meter (ACM) Reset or Query

Description: EF(ACM). ACM contains the total number of home units for both the current and preceding calls.

The write command resets the Advice of Charge related to the accumulated call meter

(ACM) value in SIM file.

Test Command Syntax: AT+CACM=?

Response:

Response:

OK

Read Command Syntax: The read command returns the current ACM value. AT+CACM?

+CACM: <acm>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CACM=[<passwd>]

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<acm>

Three bytes of the current ACM value in hexadecimal format (e.g., “00001E” indicates decimal value 30) 000000

- FFFFFF.

<passwd>

SIM PIN2

9.2 AT^SACM Advice of Charge and Query of ACM and ACMmax

Description: The execute command can be used to query the current mode of the Advice of Charge supplementary service, the SIM values of the accumulated call meter (ACM), and the accumulated call meter maximum (ACMmax).

The write command enables or disables the presentation of unsolicited result codes to report the call charges.

Test Command Syntax: AT^SACM=?

Response: ^SACM:(list of supported <n> s)

OK

Exec Command Syntax: AT^SACM.

Response: ^SACM: <n>, <acm>, <acmMax>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT^SACM=<n> .

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<n>

0 Suppress unsolicited result code. Default.

Display unsolicited result code 1

<acm>

Three bytes of the current ACM value in hexadecimal format (e.g., “00001E” indicates decimal value 30) 000000-

FFFFFF

<acmMax>

Three bytes of the max. ACM value in hexadecimal format (e.g., “00001E” indicates decimal value 30) 000000 disable ACMmax feature 000001-FFFFFF

<ccm>

Three bytes of the current CCM value in hexadecimal format (e.g., “00001E” indicates decimal value 30); bytes are coded in the same way as ACMmax value in the SIM 000000-FFFFFF

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 107

Chapter 9 – Supplementary Service Commands

Unsolicited Result Code:

+CCCM: <ccm> When activated, an unsolicited result code is sent when the CCM value changes, but not more often than every 10 seconds.

Notes:

• When you power down or reset the ME with AT+CFUN=1,1 the URC presentation mode will be reset to its default. To benefit from the URC it is recommended to have the setting included in the user profile saved with

AT&W, or to select <n>=1 every time you reboot the ME.

• See also AT+CACM, AT+CAMM, AT+CAOC.

9.3 AT+CAMM Accumulated Call Meter Maximum

(ACMmax) Set or Query

Description: The read command returns the current ACMmax value. ACMmax contains the maximum number of home units allowed to be consumed by the subscriber.

The write command sets the Advice of Charge related to the accumulated call meter maximum value in SIM file EF (ACMmax).

Test Command Syntax: AT+CAMM=?

Response: OK

Read Command Syntax: AT+CAMM?

Response: +CAMM: <acmmax>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CAMM=[<acmmax>[, <passwd>]]

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<acmmax>

Three bytes of the max. ACM value in hexadecimal format (e.g., “00001E” indicates decimal value 30) 000000 disable ACMmax feature 000001-FFFFFF.

<passwd>

SIM PIN2

9.4 AT+CAOC Advice of Charge Information

Description:

Response:

The Execute command returns the current call meter value. The write command sets the Advice of Charge supplementary service function mode.

Test Command Syntax: AT+CAOC=?

+CAOC: (list of supported<mode>s)

OK

Read Command Syntax: AT+CAOC?

Response: +CAOC: <mode>

OK

Exec Command Syntax: AT+CAOC

Response: ERROR

+CME ERROR: <err>

If <mode>=0, TA returns the current call meter value:

+CAOC: <ccm>

OK

Write Command Syntax: AT+CAOC=[<mode>].

Response: ERROR

+CME ERROR: <err>

If <mode>=0, TA returns the current call meter value.

OK

Parameter Descriptions:

<mode>

0 query CCM value

<ccm>

Three bytes of the current CCM value in hexadecimal format (e.g., “00001E” indicates decimal value 30); bytes are similarly coded as ACMmax value in the SIM 000000-FFFFFF.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 108

Chapter 9 – Supplementary Service Commands

9.5 AT+CCUG Closed User Group

Description: The Test command returns the supported parameters.

The Read command returns if the Explicit CUG invocation is activated (in parameter

<n>), which CUG <index> is chosen, and if Preferential Group or Outgoing Access is suppressed (in parameter <info>).

The Write command serves to activate or deactivate the explicit CUG invocation, to set the desired index, and to specify if Preferential Group or Outgoing Access shall be suppressed.

Test Command Syntax: AT+CCUG=?

Response: +CCUG:list of supported <n>, range of supported <index>, range of supported <info>

OK

ERROR

+CME ERROR

Read Command Syntax: AT+CCUG?

Response: +CCUG:<n>, <index>, <info>

OK

ERROR

ERROR

Write Command Syntax: AT+CCUG=[[<n>][, <index>][, <info>]]

Response: OK

ERROR

+CME

Parameter Descriptions:

<n> explicit CUG invocation options

0

1

<index>

0-9

Deactivate explicit CUG invocation

Activate explicit CUG invocation explicit selection of CUG index

10

<info> state of the call

0

No index (preferred CUG aken from subscriber data). Default.

1

2

3

Notes: no information. Default. suppress outgoing access suppress preferential CUG

Suppress preferential CUG and Outgoing Access.

• The active settings for omitted parameters are retained without changes.

• Explicit CUG invocation means that at each call setup, CUG information is added to the called number.

• Upon delivery, settings are predefined with

<n>=0,

<index>=10,

<info>=0.

These delivery defaults cannot be recalled automatically.

• When starting a call with ATD, Parameter ‘G’ or ‘g’ of command ATD will have no effect if the option selected for this single call is identical to the option already selected with AT+CCUG.

• Current settings are saved in the ME automatically.

• ATZ or AT&F do not influence the current settings.

• Some combinations of parameters may lead to rejection of CUG calls by the network.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 109

Chapter 9 – Supplementary Service Commands

9.6 AT+CCFC Call Forwarding Number and

Conditions Control

Description: AT+CCFC controls the call forwarding supplementary service. Registration, erasure, activation, deactivation and status query are supported.

Test Command Syntax: AT+CCFC=?

Response: +CCFC:(list/range of supported <reason>s)

OK

Write Command Synatx: AT+CCFC=<reason>, <mode>[, <number>[, <type>[, <class>[, <time>]]]]

Response: If <mode> is not equal 2 and command successful: OK

If <mode>= 2, <reason> is not equal 2 and command successful:

+CCFC: <status>, <class>[, <number>, <type>]

OK

If <mode>= 2, <reason>= 2 and command successful:

+CCFC: <status>, <class>[, <number>, <type>, <time>]

OK

If error is related to ME functionality: +CME ERROR

Parameter Descriptions:

<reason>

Reason for call forwarding

0

1

2

3

4 unconditional mobile busy no reply not reachable all call forwarding (includes reasons 0, 1, 2 and 3) all conditional call forwarding (includes reasons 1, 2 and 3) 5

<mode>

Network operation to be performed for Supplementary service “call forwarding”

0

1

2

3

4 disable call forwarding (disable service) enable call forwarding (enable service) query status of call forwarding (query service status) register number and activate call forwarding (register service) erase number and deactivate call forwarding (erase service)

<number>

String type phone number of forwarding address in format specified by type. If you select mode = 3, the phone

<number> will be registered in the network. This allows you to disable / enable CF to the same destination without the need to enter the phone number once again. Depending on the services offered by the provider the registration may be mandatory before CF can be used. The number remains registered in the network until you register another number or erase it using <mode> = 4.

<type>

Type of address octect

145 dialing string number includes international access code character ‘+’ otherwise 129

<class>

Integer or sum of integers each representing a class of information; i.e., a bearer service, telecommunication service or bearer service group as defined in “GSM 02.04”

1

2

4

8

16

32

64

128

1...255

<time>

5...30 voice data

Class 2 (data) comprises all those class values between 16 and 128 supported both by the network and the MS. This means, a setting for Class 2 applies to all remaining data classes (if supported). Also, you can assign a different setting to a specific class. For example, you can activate Call Forwarding for all data classes, but deactivate it for a specific data class. fax

SMS data circuit sync data circuit async dedicated packet access dedicated PAD access

Default = 7. Combination of some of the above classes. For example, the default setting 7 represents the sum of the integers 1, 2 and 4 (CF for voice, data and fax). The value 255 covers all classes. If the <class> parameter is omitted, the default value 7 is used.

Default = 20. Time to wait before call is forwarded, rounded to a multiple of 5 sec. (only for reason=no reply)

<status>

0

1

Call Forwarding not active

Call Forwarding active

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 110

Chapter 9 – Supplementary Service Commands

Notes:

• You can register, disable, enable and erase reason 4 and 5 as described above. However, querying the status of reason 4 and 5 with AT+CCFC will result in an error (“CME error: Operation not supported”). As an alternative, you may use the ATD command followed by *’# codes to check the status of these two reasons.

See Star-Hash (*#) Network Commands for a complete list of *# GSM codes. See also examples below.

• Most networks will not permit registration of new parameters for conditional call forwarding (reasons 1,2,3,5) while unconditional call forwarding is enabled.

• The AT+CCFC command offers a broad range of call forwarding options according to the GSM specifications.

However, when you attempt to set a call forwarding option which is not provisioned or not yet subscribed to, the setting will not take effect regardless of the response returned. The responses in these cases vary with the network (for example “OK”, “Operation not allowed”, “Operation not supported” etc.). To make sure check the call forwarding status with <mode>=2.

• Some networks may choose to have certain call forwarding condtions permanently enabled (e.g., forwarding to a mailbox if the mobile is not reachable). In this case, erasure or deactivation of call forwarding for these conditions will not be successful, even if the CCFC request is answered with response “OK”.

• The command has been implemented with the full set of <class> parameters according to GSM 07.07. For actual applicability of SS “call forwarding” to a specific service or service group (a specific Class value) please consult

Table A.1 of GSM 02.04.

• There is currently no release of GSM standard “GSM 02.04”, in which the “Call Forwarding” Supplementary

Service is defined as applicable to SMS services.

Example:

Please note that when you configure or query call forwarding without specifying any classes, the settings will refer to classes 1, 2 and 4 only (=default). The handling of classes is equivalent to AT+CLCK.

• To register the destination number for unconditional call forwarding (CFU): at+ccfc=0,3,”+493012345678”,145

OK

The destination number will be registered for voice, data and fax services (default <class> 7).

In most networks, the registration will also cause call forwarding to be activated for these <class> values.

• To query the status of CFU without specifying <class>: at+ccfc=0,2

+CCFC: 1,1,”+493012345678”,145

+CCFC: 1,2,”+493012345678”,145

+CCFC: 1,4,”+493012345678”,145

OK

• To deactivate CFU without specifying <class>: at+ccfc=0,0

OK

To check whether CFU was successfully deactivated (note that the destination number remains registered in the network when you disable CFU):

• To erase the registered CFU destination number: at+ccfc=0,4

OK

Now, when you check the status, no destination number will be indicated: at+ccfc=0,2

+CCFC: 0,1

+CCFC: 0,2

+CCFC: 0,4

OK

• To query the status of CFU for all classes: at+ccfc=0,2,,,255

+CCFC: 0,1

+CCFC: 0,2

+CCFC: 0,4

+CCFC: 0,8

+CCFC: 0,16

+CCFC: 0,32

+CCFC: 0,64

+CCFC: 0,128

OK

• Reason 4 or 5 cannot be used to query the status of all call forwarding reasons (see also notes above): at+ccfc=4,2

+CME error: operation not supported at+ccfc=5,2

+CME error: operation not supported

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 111

Chapter 9 – Supplementary Service Commands

9.7 AT+CCWA Call Waiting

Description: The AT+CCWA write command controls the “Call Waiting” supplementary service according to GSM 02.83. Activation, deactivation and status query are supported. The read command returns the current value of <n>.

Test Command Syntax: AT+CCWA=?

Response: +CCWA:(list of supported <n>s)

OK

Read Command Synatx: AT+CCWA?

Response: +CCWA:<n>

OK

Write Command Syntax: AT+CCWA=[[<n>][, <mode>][, <class>]]

Response: If <mode> is not equal 2 and command successful: OK

If <mode>= 2 and command successful:

+CCWA: <status>, <class>

...]

OK

If error is related to ME functionality: +CME ERROR

Parameter Descriptions:

<n>

Switch URCs “+CCWA” and “^SCWA” for call waiting on/off

0 Disable display of URCs “+CCWA” and “^SCWA”

Enable display of URCs “+CCWA” and “^SCWA” 1

<mode>

Network operation to be performed for Supplementary service call waiting

0 Disable call waiting (disable service)

Enable call waiting (enable service)

Query status of call waiting (query service status)

1

2

<class>

Integer or sum of integers each representing a class of information; i.e., a bearer service, telecommunication service or bearer service group as defined in “GSM 02.04”.

In the write command, parameter <class> specifies the class of the active call during which an incoming call of any class is to be regarded as a waiting call.

In URC “+CCWA: <calling number>, <type of number>, <class>, , <CLI validity>”, parameter <class> specifies the class of the waiting call.

1

2

Voice

Data

<class> 2 (data) comprises all those <class> values between 16 and 128, that are supported both by the network and the MS. This means, a setting made for <class> 2 applies to all

4

7

8

16

32

64

128

1...255 remaining data classes (if supported). In addition, you can assign a different setting to a specific class. For example, you can activate call waiting for all data classes, but deactivate it for a specific data class.

Fax

Voice, data and fax (1+2+4). Default.

SMS

Data circuit sync

Data circuit async

Dedicated packet access

Dedicated PAD access

Default = 7. Combination of some of the above classes. For example, the default setting 7 represents the sum of the integers 1, 2 and 4 (CF for voice, data and fax). The value 255 covers all classes. If parameter “class”is omitted, the default value 7 is used.

<status>

0

1

<calling number>

Call waiting service is not active

Call waiting service is active

Phone number of waiting caller in the format specified by parameter <type of number>.

<type of number>

Type of address octet in integer format (refer to GSM 04.08, subclause 10.5.4.7)

145 <calling number> includes international access code character ‘+’

129

<CLI validity>

0

1

2

Otherwise

CLI valid

CLI has been withheld

CLI is not available

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 112

Chapter 9 – Supplementary Service Commands

Unsolicited Result Codes:

URC 1

Indication of a call that is currently waiting and can be accepted.

+CCWA: <calling number>, <type of number>, <class>, , <CLI validity>

If <n>=1 and the call waiting supplementary service is enabled in the network, URC “+CCWA” indicates a waiting call to the TE. It appears while the waiting call is still ringing.

URC 2

Indication of a call that has been waiting.

^SCWA

If <n>=1 and the call waiting supplementary service is enabled in the network, this URC indicates that a waiting call rang when the ME was in online mode during a CSD call, but the calling party hung up before the ME went back to command mode.

Notes

• If the active call is a CSD call, and a waiting call is received, then the ME produces a BREAK while still in online mode, and displays

∗ the +CCWA URC (as above) when the ME goes back to command mode while the waiting call is still active and can be accepted;

∗ or the ^SCWA URC (as above) when the ME goes back to command mode after the waiting call has ended.

• With the AT+CHLD command, it is possible to establish a multiparty call or to set the active voice call on hold and then accept a waiting voice call (not possible with fax and data call). See also AT+CHLD

• Users should be aware that if call waiting is activated (<mode>=1), the presentation of URCs needs to be enabled, too (<n>=1).

Otherwise, on the one hand, a waiting caller would be kept waiting due to lack of BUSY signals, while, on the other hand, the waiting call would not be indicated to the called party.

• The AT+CCWA command offers a broad range of options according to the GSM specifications. However, when you attempt to enable call waiting for a <class> for which the service is not provisioned or not supported, the setting will not take effect regardless of the response returned. The responses in these cases vary with the network (for example “OK”, “Operation not allowed”, “Operation not supported” etc.). To make sure check the current call waiting settings with <mode>=2.

• The AT+CCWA command has been implemented with the full set of <class> parameters according to GSM

07.07. For actual applicability of SS call waiting to a specific service or service group (a specific <class> value) please consult table A.1 of GSM 02.04

• Despite the specifications stated in GSM 02.04 call waiting is not handled uniformly among all networks: GSM

02.04, Annex A, provides the following specification:

“The applicability of call waiting refers to the telecommunication service of the active call and not of the waiting call. The incoming, waiting, call may be of any kind.” Nevertheless, networks do differ on the actual implementation of the service. For example, the activation of call waiting for <class> 4, “fax”, causes some networks to send a call waiting indication if a call “of any kind” comes in during an active fax call, but others may

(with the same settings active) indicate a waiting fax call during any kind of active call. Thus, the only reliable way to receive or prevent a call waiting indication under any circumstances and in any network, is to activate or deactivate call waiting for all tele- and bearer services (<class> 255).

Examples

Example 1

Parameter <n> at+ccwa=1 To enable the presentation of the URC

OK

Example 2

Parameter <mode> at+ccwa=,1 To activate the supplementary service in the network for voice, data, and fax calls (default classes).

Note that parameter <n> is left out. In this case, the current value of <n> will be retained.

OK at+ccwa=,2 at+ccwa=1,1 at+ccwa=1,2 at+ccwa=1,4

OK

Example 3

Parameter <class>

AT+CCWA=,0,1

OK

To query the network status of call waiting for default classes

Call Waiting is activated during voice calls.

Call Waiting is activated during data calls.

Call Waiting is activated during fax calls.

To deactivate call waiting for voice calls.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 113

Chapter 9 – Supplementary Service Commands

9.8 AT+CHLD Call Hold and Multiparty

Description:

1X

TA controls the Supplementary Services Call Hold and Multiparty. Calls can be put on hold, recovered, released, and added to a conversation.

As for all Supplementary Services, the availability and detailed functionality of Call Hold and Multiparty services depends on the configuration of the GSM network. The Multi-Tech wireless modem can only request the service, but the network decides whether and how the request will be answered.

Test Command Syntax: AT+CHLD=?

Response:

Response:

+CHLD: (list of supported <n>s)

OK

Write Command Syntax: AT+CHLD=[<n>]

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<n>

0

1

Release all held calls or set User Determined User Busy (UDUB) for a waiting call:

• If a call is waiting, release the waiting call. The calling party will receive a “BUSY” indication

(Supplementary Service User Determined User Busy “UDUB”)

• Otherwise, terminate all held calls (if any).

Terminate all active calls (if any) and accept “the other call” as the active call:

• If a call is waiting, the waiting call will be accepted.

• Otherwise, if a held call is present, the held call becomes active.

Terminate a specific call X (X= 1-7). The call may be active, held or waiting.

The remote party of the terminated call will receive a “NO CARRIER” indication.

2

2X

Parameter X is the call number <idx> of the targeted call in the list of current calls available with

AT command AT+CLCC.

Place all active calls on hold (if any) and accept “the other call” as the active call:

• If a call is waiting, the waiting call will be accepted.

• Otherwise, if a held call is present, the held call becomes active.

Place all active calls except call X (X= 1-7) on hold. Parameter X is the call number <idx> of the targeted call in the list of current calls available with AT command AT+CLCC.

Add a held call to the active calls in order to set up a conference (multiparty) call. 3

Notes:

• The AT+CHLD command offers a broad range of options according to the GSM specifications. However, if you attempt to invoke an option which is not provisioned by the network, or not subscribed to, invocation of this option will fail. The responses in these cases may vary with the network (for example “Operation not allowed”,

“Operation not supported” etc.).

• The handling of the supplementary service Call hold and Multiparty varies with the types of calls. This is because only voice calls can be put on hold, while data or fax calls cannot. The following procedures apply:

With AT+CHLD=2 the user can simultaneously place a voice call on hold and accept another waiting voice, data or fax call. If the waiting call is a data or fax call, it is also possible to put the voice call on hold. To switch back from the active data or fax call to the held voice call the active call must be terminated with AT+CHLD=1. If all active and held calls are voice calls it is possible to switch back and forth with AT+CHLD=2.

• In conflict situations (e.g., when a waiting call comes while there are already held calls), the above procedures apply to the waiting call only. For example, <n>=0 rejects the waiting call, but does not affect the held calls.

• See also the AT+CCWA command for details on how to display waiting calls.

See the Example on the next page.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 114

Chapter 9 – Supplementary Service Commands

Example

^SYSSTART at+cpin=”9999”

OK

+CREG: 2

+CREG: 1,”0145”,”0016” at+ccwa=1,1,1

OK atd”1234567”;

OK

+CCWA: “+491791292364”,145,32,,0 at+chld=2

CONNECT 9600/RLP hello

+++

OK at+clcc

+CLCC: 1,0,1,0,0,”03038639268”,129

+CLCC: 2,1,0,1,0,”+491791292364”,145

OK at+chld=1

The mobile is now registered.

You activate the indication of waiting calls during voice calls.

You make a voice call.

You receive a URC indicating a waiting data call.

You put the voice call on hold.

The data connection is set up.

With “+++” you go in command mode.

You interrogate the status of all established calls.

The active data call is terminated and the held voice call becomes active.

OK at+clcc

+CLCC: 1,0,0,0,0,”03038639268”,129

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 115

Chapter 9 – Supplementary Service Commands

9.9 AT+CLIP Calling Line Identification

Presentation

Description: This command refers to the GSM supplementary service CLIP (Calling Line Identification

Presentation) that enables a called subscriber to get the calling line identity (CLI) of the calling party when receiving a mobile terminated call.

Test Command Syntax: AT+CLIP=? The test command returns values supported by the TA as a compound value.

Response: +CLIP: (list of supported<n>s)

OK

Read CommandSyntax: AT+CLIP? The read command gives the status of <n>, and also triggers an interrogation of the provision status of the CLIP service according GSM 02.81 (given in <m>).

Response:

If no SIM card is available or SIM-Pin isn’t entered, the command response is “ERROR”.

+CLIP: <n>, <m>

OK

ERROR

Write Command:

+CME ERROR: <err>

AT+CLIP=<n> The write command enables or disables the presentation of the CLI at the TE. It has no effect on the execution of the supplementary service CLIP in the network.

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<n>

0

1

<m>

0

Suppress unsolicited result codes. Default

Display unsolicited result codes

CLIP not provisioned

1

2

CLIP provisioned unknown

<number> string type phone number of calling address in format specified by type.

<type> type of address octet in integer format; 145 when dialing string includes international access code character “+”, otherwise 129.

<alpha> string type alphanumeric representation of number corresponding to the entry found in phonebook; used character set should be the one selected with command Select TE Character Set AT+CSCS

<CLI validity>

0 CLI valid

1

2

CLI has been withheld by the originator.

CLI is not available due to interworking problems or limitations of originating network. Number shall be an empty string (“”) and type value will not be significant.

When CLI is not available ( <CLI validity>=2), number shall be an empty string (“”) and type value will not be significant. Nevertheless, TA shall return the recommended value 128 for type (TON/NPI unknown in accordance with GSM 04.08 subclause 10.5.4.7).

When CLI has been withheld by the originator, (<CLI validity>=1) and the CLIP is provisioned with the “override category” option (refer GSM 02.81 and GSM 03.81), number and type is provided. Otherwise, TA shall return the same setting for number and type as if the CLI was not available.

Unsolicited Result Codes:

URC 1

Voice call response format:

+CLIP: <number>, <type>, , [, <alpha>][, <CLI validity>]

URC 2

Data/FAX call response format:

+CLIP: <number>, <type>

When CLIP is enabled at the TE (and is permitted by the calling subscriber), an unsolicited result code is returned after every RING (or +CRING: <type>) at a mobile terminating call.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 116

Chapter 9 – Supplementary Service Commands

9.10 AT+CLIR Calling Line Identification

Restriction

Description: The AT+CLIR command refers to the GSM supplementary service CLIR. The settings made with AT+CLIR=1 or AT+CLIR=2 are used for all outgoing calls until the ME is switched off or AT+CLIR=0 is used.

Test Command Synatx: AT+CLIR=?

Response: +CLIR: (list of supported <n>s)

OK

Read Command Synatx: AT+CLIR?

Response: +CLIR <n> , <m>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CLIR=[<n>]

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<n> Parameter shows the settings for outgoing calls:

0

1

2

Presentation indicator is used according to the subscription of the CLIR service

CLIR invocation

CLIR suppression

<m> Parameter shows the subscriber CLIR service status in the network:

0

1

2

3

4

CLIR not provisioned

CLIR provisioned in permanent mode

Unknown (e.g., no network, etc.)

CLIR temporary mode presentation restricted

CLIR temporary mode presentation allowed

9.11 AT+COLP Connected Line Identification

Presentation

Description: This command refers to the GSM supplementary service COLP that enables a calling subscriber to get the connected line identity (COL) of the called party after setting up a mobile originated call. The command enables/disables the presentation of the COL at the

TE. It has no effect on the execution of the supplementary service COLR in the network.

Test Command Syntax: AT+COLP=?

Response: +COLP:(list of supported <n>s)

OK

Read Command Syntax: AT+COLP?

Response: +COLP: <n>, <m>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+COLP=[<n>]

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<n>

0 Disable - suppress unsolicited result codes

Enable - display unsolicited result codes 1

<m>

0

1

2

<number>

COLP not provisioned (no presentation)

COLP provisioned

Unknown

String type phone number of connected address in format specified by <type>

<type>

Type of address octet in integer format; 145 when dialing string includes international access code character “+”; otherwise, 129.

Unsolicited Result Code:

Call response format: +COLP: <number>, <type>

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 117

Chapter 9 – Supplementary Service Commands

9.12 AT+CPUC Price Per Unit and Currency Table

Description: The read command returns the current parameters of PUC.

The currency table. SIM PIN2 is usually required to set the parameters.

Test Command Syntax: AT+CPUC=?

Response: OK

Read Command Syntax: AT+CPUC?

Response: +CPUC: <currency>, <ppu>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CPUC=<currency>, <ppu>[, <passwd>]

Response: OK

ERROR

Parameter Descriptions:

+CME ERROR: <err>

<currency>

Three-character currency code (e.g., “GBP”, “EUR”). If the currency name is longer than three characters, all characters will be cut off after the third position. Before they are written to the SIM Card, these characters are converted to the standard GSM alphabet.

<ppu>

Price per unit; dot is used as a decimal separator (e.g., “2.66”). The length is limited to 20 characters. If the string length is exceeded, the command is terminated with an error. This string may only contain digits and a dot.

Leading zeros are removed from the string. The minimum and maximum value are determined by the structure of the SIM-PUCT file. The maximum price per unit value is 999 999 999.00. When successfully entered, this value is rounded to maximum accuracy.

Note: Due to storage in mantisse (range 0-4095) and exponent (-7 to 7) it is possible that rounding errors occur.

<passwd>

SIM PIN2. String parameter which can contain any combination of characters. The maximum string length is limited to 8 characters. If this value is exceeded, the command terminates with an error message. If the PIN2 is incorrect, a CME error (+CME ERROR: incorrect password) is output.

Example:

Two ways to change currency and/or price per unit:

1. You can enter PIN2 along with the AT+CPUC command:

AT+CPUC=”EUR”,”0.10”,”8888” (where “8888” = PIN2)

OK

2. Alternatively, you can first use the AT+CPIN2 command to enter PIN2. When you execute the AT+CPUC command, subsequently, take into account that PIN2 authentication expires after 300ms (see notes in

AT+CPIN2).

AT+CPUC=”EUR”,”0.10”

OK

AT+CPUC=”EUR”,”0.10”

Successful

+CME ERROR: SIM PIN2 required Attempt not successful. PIN2 authentication has expired.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 118

Chapter 9 – Supplementary Service Commands

9.13 AT+CSSN Supplementary Service

Notifications

Description:

Response:

The write command enables or disables the presentation of URCs for supplementary services.

Test Command Syntax: AT+CSSN=?

+CSSN: (list of supported<n>s), (list of supported<m>s)

OK

Read Command Syntax: AT+CSSN?

Response: +CSSN: <n>, <m>

OK

Write Command Syntax: AT+CSSN=<n>[, <m>]

Response: OK

ERROR

+CME

Parameter Descriptions:

<n>

0

1

<m>

0

Suppress “+CSSI” URCs. Default.

Activate “+CSSI” URCs

Suppress “+CSSU” URCs. Default.

1

<code 1>

0

1

2

3

<code 2>

0

5

10

Activate “+CSSU” URCs unconditional call forwarding is active some of the conditional call forwardings are active call has been forwarded

Waiting call is pending

The incoming call is a forwarded call.

Held call was terminated unconditional call forwarding is active

Unsolicited Result Codes:

URC 1

+CSSI: <code 1>

When <n>=1 and a supplementary service notification is received after a mobile originated call setup, intermediate result code “+CSSI: <code 1>” is sent to TE before any other MO call setup result codes.

URC 2

+CSSU: <code 2>

When <m>=1 and a supplementary service notification is received during a mobile terminated call setup or during a call, unsolicited result code “+CSSU: <code 2>” is sent to TE.

Note: URCs will be displayed only if the call concerned is a voice call, but some URCs will be displayed as well as for data calls (like “+CSSU”=0).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 119

Chapter 9 – Supplementary Service Commands

9.14 AT+CUSD Supplementary Service

Notifications

Description: This command allows control of the Unstructured Supplementary Service Data (USSD).

Both network and mobile initiated operations are supported.

Test Command Syntax: AT+CUSD=?

Response: +CUSD: (list of supported<n>s)

OK

Read Command Syntax: AT+CUSD? The read command returns the current <n> value.

Response: +CUSD: <n>

OK

Write Command Syntax: AT+CUSD=<n>[, <str>[, <dcs>]]

The write command parameter <n> is used to disable/enable the presentation of an unsolicited result code (USSD response from the network, or network initiated operation)

“+CUSD: <m>[<str>[<dcs>]]” to the TE.

When <str> is given, a mobile initiated USSD string or a response USSD string to a network initiated operation is sent to the network. The response USSD string from the network is returned in a subsequent unsolicited result code “+CUSD”

Response: OK

ERROR

Parameter Descriptions:

<n>

0

1

2

<str>

Disable the result code presentation in the TA. Default.

Enable the result code presentation in the TA

Cancel session (not applicable to read command response)

String type USSD-string (when <str> parameter is not given, network is not interrogated).

If <dcs> indicates that GSM 03.38 default alphabet is used, TA converts GSM alphabet into current TE character set according to rules of GSM 07.05 Annex A.

<dcs>

GSM 03.38 Cell Broadcast Data Coding Scheme in integer format (default 15).

<m>

0 No further user action required (network initiated USSD-Notify, or no further information needed after mobile initiated operation)

1

2

Further user action required (network initiated USSD-Request, or further information needed after mobile initiated operation).

If <m>=1, then the URC ends with “>” to prompt the user for input. The user action is finished with <CTRL-Z> or aborted with <ESC>.

USSD terminated by network.

Unsolicited Result Code:

+CUSD: <m>[<str>[<dcs>]]

URC “+CUSD” indicates an USSD response from the network, or network initiated operation.

Notes:

• For the write command, only <dcs>= 15 is supported.

• When a USSD string is sent via ATD, a “AT+CUSD=1” is executed implicitly.

• It is recommended to finalize or escape a pending USSD user interaction before further actions are done to prevent blocking situations.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 120

Chapter 10 – Internet Service Commands

Chapter 10. Internet Service

Commands

The Multi-Tech Wireless EDGE modem has an embedded TCP/IP stack that is driven by AT commands and enables the host application to easily access the Internet. The advantage of this solution is that it eliminates the need for the application manufacturer to implement its own TCP/IP and PPP stacks, thus minimizing cost and time to integrate

Internet connectivity into a new or existing host application. This chapter is a reference guide to all the AT commands and responses defined for use with the TCP/IP stack.

Access is provided to the following Internet Services:

1. Socket Client and Server for TCP, Client for UDP

2. FTP Client

3. HTTP Client

4. SMTP Client

5. POP3 Client

Step-by-step instructions on how to configure and use TCP/IP communications with Multi-Tech Wireless

EDGE modem:

First of all, create a connection profile with AT^SICS. The connection profile is a set of basic parameters that determine the type of connection to use for an Internet service. Up to 6 connection profiles can be defined, each identified by the <conProfileId>.

Secondly, use AT^SISS to create a service profile based on one of the connection profiles. Up to 10 service profiles can be defined, each identified by the <srvProfileId>. The service profile specifies the type of

Internet service to use, i.e. Socket, FTP, HTTP, or one of the email services SMTP or POP3. To assign a

connection profile to a service profile, the <conProfileId> of AT^SICS must be entered as “conId” value of the AT^SISS parameter <srvParmTag>.

This offers great flexibility to combine connection profiles and service profiles. For example, you may have one connection profile (CSD or GPRS) specified with AT^SICS which can be associated with an SMTP service profile for sending emails and a POP3 service profile for retrieving emails.

Once the connection profile and the service profile are created, an Internet session can be opened by entering the AT^SISO write command and the desired <srvProfileId>. Wait for the resulting URC.

The next command determines the action to be performed, for example reading data with AT^SISR or writing data with AT^SISW. Wait for the resulting URC.

Finally, to end a session, enter the AT^SISC write command and the <srvProfileId>.

Maximum number of profiles defined / used:

Up to 6 connection profiles can be created (with AT^SICS).

Up to 10 service profiles can be created (with AT^SISS), but the number of parallel profiles of the same service type is limited as listed below. If the maximum number of a service profile type is already defined, any attempt to set up another profile for the same type will be denied with “+CME ERROR: unknown”.

- Maximum 3 HTTP profiles

- Maximum 6 socket profiles: Only two instances can be opened for the listener. This means that if two listeners are established another four instances can be opened for clients. Also, the socket service can accept an incoming connection only when at least one service profile is still free (not yet created with AT^SISS); otherwise, the incoming connection will be closed to the listener. If there is no listener established, all six socket profiles can be configured as Client.

- 1 FTP profile

- 1 POP3 profile

- 1 SMTP profile

The TCP/IP stack of Multi-Tech Wireless EDGE modem supports using several service profiles at the same time, provided all of them are running on the same connection profile. For example, it is possible to download files from an FTP server, while sending and receiving emails at the same time.

GPRS connections established over the Dial-Up Network do not use the embedded TCP/IP stack of Multi-

Tech Wireless EDGE modem and can be active at the same time. This allows the user to have two parallel

GPRS connections: for example for sending or receiving emails over a GPRS connection enabled by the

TCP/IP stack while, at the same time, surfing the Internet over a Dial-Up Network GPRS connection.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 121

Chapter 10 – Internet Service Commands

Using Internet Service AT commands on several interfaces (ASC0, ASC1, USB or Multiplex mode on ASC0):

A connection profile can be created on one interface and then viewed or changed on all other interfaces.

A service profile can be used only on one interface at a time:

Changes to a service profile are allowed only on the same interface where it was created, trying to change it on another interface is denied with “+CME ERROR: Invalid index”. If queried with the read command AT^SISS the entire profile is returned on the interface where the service profile was created, while on all other interfaces only the service type of the profile is stated.

If a service profile is active (after opening it with AT^SISO) on one interface, any attempt to open or close the same service profile on another interface is denied with “+CME ERROR: Operation temporary not allowed”.

To free a service profile for use on another interface, use the AT^SISS command and select service type = “none”. This action deletes the entire profile and restores all parameters of the profile to their initial power-up state (all values are empty). For example, to remove the service profile 3, set AT^SISS=3,svrtype, none. After this, a new profile 3 can be created on any other interface.

Address Notation:

Server addresses must be provided as IP addresses in standard dot-format (e.g., “192.168.1.2”) or as server address names resolvable by a DNS server (e.g., “smtp.myserver.de” or “pop3.myserver.de”).

Inactivity Timeouts:

Inactivity timeouts are not part of the Internet AT command functionality implemented with Multi-Tech wireless modem and, if desired, are the responsibility of the host application. It is recommended that the host application validates URCs and AT command responses and reacts adequately. Example: Sending a close message or a starting timer.

10.1 AT^SICS Internet Connection Setup Profile

Description: AT^SICS serves to create and edit Internet connection profiles. A connection profile can be assigned to one or more service profiles defined with AT^SISS, and thus, determines which type of connection is to be established when opening a service profile with AT^SISO.

The AT^SICS read command requests the current settings of all Internet connection profiles. One line is issued for every possible parameter of a given <conParmTag> “conType” value.

The AT^SICS write command specifies all parameters of a connection profile identified by

<conProfileId>. At first, the type of Internet connection needs to be selected via <conParmTag> value “conType”. This determines the applicability of all other <conParmTag> values related to this

“conType” and automatically sets their defaults. An exception to the <conParmValue-alphabet> which can be set before or after selecting “con-Type”. To change the settings the write command needs to be executed for each single <conParmTag>.

All profile parameters set with AT^SICS are volatile. Therefore, the best practice is to use scripts and let the host application handle the required At commands.

Table 10.1: Applicability of AT^SICS <conParmTag> values

<conParmTag> value

“conType”

CSD mandatory

GPRS0 / GPRS1 mandatory

“user” optional optional optional

ø

“authMode” mandatory mandatory

“dns1”

“dns2” optional optional optional optional

Test Command Syntax:

Response:

Read Command Syntax:

Response:

AT^SICS=?

OK

AT^SICS?

^SICS: <conProfileId>, <conParmTag>, <conParmValue>

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 122

Chapter 10 – Internet Service Commands

Write Command Syntax:

Response:

AT^SICS=<conProfileId>, <conParmTag>, <conParmValue>

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<conProfileId>

Internet connection profile identifier.

The <conProfileId> identifies all parameters of a connection profile, and, when a service profile is created with AT^SISS the <conProfileId> needs to be set as “conId” value of the AT^SISS parameter <srv-ParmTag>.

0...5

<conParmTag>

Internet connection parameter.

“conType“ Type of Internet connection.

“alphabet“

For supported values of <conParmValue> refer to <conParmValue-con-Type>.

Selects the character set for input and output of string parameters within a profile.

The selected value is bound to the specific profile. This means that different profiles may use different alphabets. Unlike other parameters, the alphabet can be changed whether or not <conParmTag> value “conType” has been set.

“user“

For supported values of <conParmValue> refer to <conParmValuealphabet>.

User name string: maximum 32 characters (where “” is default).

“passwd“

“apn“

“inactTO“

“calledNum“

“dataRate“

“dataType“

“authMode“

“dns1“

“dns2“

Password string: maximum 32 characters (where “” is default). If the <conParmValueauthMode> is “MsChapV1”, then the maximum password length is 16 characters.

Access point name string value: maximum 100 characters (where “” is default).

Inactivity timeout value in seconds: 0. Changing the value is not allowed.

Called BCD number.

Data rate.

For supported values of <conParmValue> refer to <conParmValue-dataRate>.

Data call type.

For supported values of <conParmValue> refer to <conParmValuedataType>.

Authentication mode.

For supported values of <conParmValue> refer to <conParmValue-auth-Mode>.

Primary DNS server address (IP address in dotted-four-byte format).

This value determines whether to use the DNS server addresses dynamically assigned by the network or a specific DNS server address given by the user.

“dns1” = “0.0.0.0” (default) means that the CSD or GPRS connection profile uses dynamic DNS assignment. Any other address means that the Primary DNS is manually set.

The default value applies automatically if no other address is set. Note that the

AT^SICS read command only returns a manually configured IP address, while the value “0.0.0.0” is not indicated at all, no matter whether assumed by default or explicitly specified.

Secondary DNS server address (IP address in dotted-four-byte format).

If “dns1” = “0.0.0.0” this setting will be ignored. Otherwise this value can be used to manually configure an alternate server for the DNS1.

If “dns1” is not equal “0.0.0.0” and no “dns2” address is given, then “dns2”=”0.0.0.0” will be assumed automatically. The AT^SICS read command only returns a manually configured IP address, while the value “0.0.0.0” is not indicated at all, no matter whether assumed by default or explicitly specified.

<conParmValue>

Parameter value; type and supported content depend on related <conParmTag>.

<conParmValue-conType>

Supported connection type values in <conParmValue> for <conParmTag> value “conType”.

“CSD“ Circuit-switched data call.

“GPRS0“ GPRS connection.

Settings of GPRS related commands are not used, e.g. AT+CGDCONT. When a service that is based on a GPRS connection profile is started after entering AT^SISO, the wireless modem automatically tries to attach to the GPRS. Yet, the only exception is AT+CGATT which can be used anytime to detach from the GPRS and, thus, disconnect the bearer opened with AT^SISO.

“none” Clears the connection profile.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 123

Chapter 10 – Internet Service Commands

<conParmValue-alphabet>

Character set selectable with <conParmValue> for <conParmTag> value “alphabet”.

“0“

“1“

Character set determined with AT+CSCS applies. Default.

International Reference Alphabet (IRA, seven bit ASCII) applies.

<conParmValue-dataRate>

Supported data rate values in <conParmValue> for <conParmTag> value “dataRate”.

“0“

“1“

14.4 KBaud

9.6 KBaud. Default.

<conParmValue-dataType>

Supported data call type values in <conParmValue> for <conParmTag> value “dataType”.

“0“

“1“

ISDN

Analog. Default,

<conParmValue-authMode>

Supported authentication mode values in <conParmValue> for <conParmTag> value “authMode”.

“none“

“PAP“ (Default)

“CHAP“

“MsChapV1“

10.1.1 Example: Default Values of a CSD Connection Profile

As stated earlier, the “conType” selected with AT^SICS determines all other matching profile parameters related to this “conType”. Once “conType” is set in a new profile, the default values of all other related parameters are assumed. To view the default settings you can use the read command AT^SICS?

Select connection type CSD, identified by <con-ProfileId>1 at^sics=1,conType,CSD

OK at^sics?

^SICS: 0, “conType”, “”

^SICS: 1, “conType”, “CSD”

^SICS: 1, “alphabet”, “0”

^SICS: 1, “user”, “”

^SICS: 1, “passwd”, “”

^SICS: 1, “authMode”, “PAP”

^SICS: 1, “inactTO”, “0”

^SICS: 1, “calledNum”, “”

^SICS: 1, “dataRate”, “1”

^SICS: 1, “dataType”, “1”

^SICS: 2, “conType”, “”

^SICS: 3, “conType”, “”

^SICS: 4, “conType”, “”

^SICS: 5, “conType”, “”

OK

Query current profiles.

Profile with <conProfileId> 0 is still empty.

The new CSD profile just created is indicated with all related parameters set to their default.

Character set determined with AT+CSCS applies when string parameters are input with AT^SICS.

No user name set.

No password set.

Authentication protocol PAP is assumed as default.

No inactivity timeout set.

No destination set.

Data rate set to 9.6 kbaud.

Remote device is analog, e.g. an analog modem.

Profile with <conProfileId> 2 is still empty.

Profile with <conProfileId> 3 is still empty.

Profile with <conProfileId> 4 is still empty.

Profile with <conProfileId> 5 is still empty.

10.1.2 Example: GPRS Connection Profile

at^sics=0,conType,GPRS0

OK

AT^SICS=0,inactTO,”0”

OK

AT^SICS=0,dns1,”193.254.160.1”

OK

AT^SICS=0,authMode,”PAP”

OK

AT^SICS=0,passwd,t-d1

Select connection type GPRS0.

Inactivitiy timeout = 0 (default).

IP address of Primary DNS server.

Authentication protocol PAP (default).

GPRS services password provided by the German operator

T-D1.

OK

AT^SICS=0,apn,”internet.t-d1.de” APN to access the GPRS services provided by the German operator T-D1.

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 124

Chapter 10 – Internet Service Commands

10.2 AT^SISS Internet Service Setup Profile

Description: AT^SISS serves to set up the necessary parameters in the Internet service profiles. Any service profile can then be used to control a data link in conjunction with AT^SISO, AT^SISC, AT^SISR and

AT^SISW.

The read command requests the current settings of all Internet service profiles. One line is issued for every possible parameter of a given <srvParmTag> “srvType” value.

The write command specifies the parameters for a service profile identified by <srvProfileId>. At first the type of Internet service needs to be selected via <srvParmTag> value “srvType”. This determines the applicability of all other <srvParmTag> values related to this “srvType” and sets their defaults. An exception is <srvParmTag-alphabet> which can be set before or after selecting

“srvType”. To change the settings the write command needs to be executed for each single

<srvParmTag>.

All profile parameters set with AT^SISS are volatile. Therefore, the best practice is to use scripts and let the host application handle the required AT commands.

The list below shows which <srvParmTag> parameters apply to each Internet service and which of them are mandatory or optional.

1. “Socket”

• “address” (mandatory)

• “conId” (mandatory) – Internet connection profile.

• “alphabet” (optional)

2. “FTP”

• “address” (mandatory)

• “conId” (mandatory) – Internet connection profile.

• “alphabet” (optional)

3. “HTTP”

• “user” (optional)

• “passwd” (optional)

• “address” (mandatory)

• “conId” (mandatory) – Internet connection profile.

• “alphabet” (optional)

• “hcContent” (optional)

• “hcContLen” (optional)

• “hcUsrAgent” (optional)

• “hcMethod” (mandatory)

• “hcProp” (optional)

• “hcRedir” (optional)

• “hcAuth” (optional)

4. “SMTP”

• “user” (optional) – User name to be used for SMTP authentication.

• “passwd” (optional) – Password to be used for SMTP authentication.

• “address” (mandatory) – SMTP server address.

• “tcpPort” (optional) – TCP port number of SMTP Server.

• “conId” (mandatory) – Internet connection profile.

• “alphabet” (optional)

• “smFrom” (mandatory) – Email sender (“MAIL FROM”) address.

• “smRcpt” (mandatory) – Recipient (“RCPT TO”) address.

• “smCC” (optional) – CC address of the email.

• “smSubj” (optional) – Subject content of the email.

• “smHdr” (optional) – Additional header fields of the email.

• “smAuth” (optional) – SMTP authentication control flag.

5. “POP3”

• “user” (mandatory)

• “passwd” (mandatory)

• “address” (mandatory) – POP3 server address.

• “tcpPort” (optional) – POP3 Server TCP Port Number.

• “conId” (mandatory) – Internet connection profile.

• “alphabet” (optional)

• “pCmd” (optional) – POP3 user command.

• “pNumber” (optional) – Message number argument.

• “pLength” (optional) – Maximum message length.

• “pDelFlag” (optional) – Delete message on server flag.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 125

Chapter 10 – Internet Service Commands

Test Command Syntax: AT^SISS=?

Response: OK

Read Command Syntax: AT^SISS?

Response: ^SISS: <srvProfileId>, <srvParmTag>, <srvParmValue>

OK

Write Command Syntax: AT^SISS=<srvProfileId>, <srvParmTag>, <srvParmValue>

Response: OK

ERROR

Parameter Description:

+CME ERROR: <err>

<srvProfileID>

Internet service profile identifier.

The <srvProfileId> is used to reference all parameters related to the same service profile. Futhermore, when using the AT commands AT^SISO, AT^SISR, AT^SISW, and AT^SISC, the <srvProfileId> is needed to select a specific service profile. 0...9

<srvParmTag>

Internet service profile parameter.

“srvType“

“alphabet“

Type of Internet service to be configured with consecutive usage of

AT^SISS

For supported values of <srvParmValue> refer to <srvParmValue-srv-Type>.

Selects the character set for input/output of string parameters within a profile.

.

The selected value is bound to the specific profile. This means that different profiles may use different alphabets. Unlike other parameters the alphabet can be changed regardless of whether the <srvParmTag> value “srvType” has been set.

For supported values of <srvParmValue> refer to <srvParmValuealphabet>.

“user“

“passwd“

User name string

1. Socket. Not applicable; set within “address” parameter.

2.

FTP. Not applicable; set within “address” parameter.

3.

HTTP. User name for the HTTP authentication mechanism. Currently only HTTP simple authentication is supported.

4.

SMTP. User name to be used for SMTP authentication (string).

Length: 4...64.

If SMTP authentication is disabled; i.e., “smAuth” flag not set, user name parameter will be ignored.

5.

POP3.

Length: 1...64.

Used to perform authentication with a POP3 server, e.g. “john.smith”.

Password string

1. Socket. Not applicable; set within “address” parameter.

2. FTP. Not applicable; set within “address” parameter.

3. HTTP. Password for the HTTP authentication mechanism. Currently HTTP simple authentication is supported only.

4. SMTP. Password to be used for SMTP authentication (string).

4...64

If SMTP authentication is disabled, i.e. “smAuth” flag not set, password parameter will be ignored.

5. POP3. Server/mailbox-specific password (string).

Length: 1...64.

Used to perform authentication with a POP3 server.

“conId“

“tcpPort“

Internet connection profile to be used, for details refer AT^SICS.

TCP Port Number

1. Socket.

2.

FTP.

Not applicable; set within “address” parameter.

Not applicable; set within “address” parameter.

3. HTTP. Not applicable; set within “address” parameter.

If parameter is omitted the service connects to HTTP default port 80.

4. SMTP. SMTP server TCP port number

Length: 0...2

16 - 1

If this parameter is not set, SMTP default port number 25 is used.

POP3 server TCP port number (numeric).

Length: 0...2

16

- 1

If this parameter is not set, POP3 default port number 110 is used.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 126

“address“

Chapter 10 – Internet Service Commands

String value, depending on the service type either a URL in the case of Socket, FTP and HTTP or an address in the case of SMTP and POP3:

1. Socket

• Socket type TCP client URL

“socktcp://’host’:’remote tcpPort’[;disnagle=’0|1’] “

“disnagle” is optional for disabling the TCP Nagle algorithm.

0: Nagle algorithm is enabled. Default.

1: Nagle algorithm is disabled.

• Socket type TCP server URL

“socktcp://listener:’local tcpPort’ “

• Socket type UDP client URL

“sockudp://’host’:’remote udpPort’[;size=’byte’][;port=’word’]”

Parameter “size” (optional):

0: PDU size is variable. Default.

1...1500: Fixed PDU size in bytes.

Parameter “port” (optional):

0: Port number will assigned from service. Default.

1...2

2. FTP

16 – 1: defines the local port number of the UDP client.

• FTP client URL (get)

“ftp://’user’:’password’@’host’:’tcpPort’/’url-path’ [;type=’a|i|d’] “

Refer “IETF-RFC 1738”.

• FTP client URL (put)

“ftpput://’user’:’password’@’host’:’tcpPort’/’url-path’/’element name’

[;type=’a|i’][;size=’length’][;mode=’u|a|d’] “

Used parameters:

“host” is mandatory; all other parameters are optional. If “password” is set, then “user” must be set as well.

If “user” is omitted, the string “anonymous” is selected for “user” and

“password”.

If “password” is omitted, the password request is served by an empty string.

If “tcpPort” is omitted, the service connects to the FTP default port 21.

If “url-path” contains only the IP address, a directory listing is requested.

If “url-path” contains only the IP address and has a slash ‘/’ appended, a detailed directory listing is requested.

“type”: [a)scii | i)mage | d)irectory]

“size”: Specifies the total amount of upload data. For each part, the transmission is triggered by the URC “^SISW: x, 1”, then the

AT^SISW write command can be executed. After the last packet the

URC “^SISW: x, 2” indicates that all data have been transferred and the FTP connection is shut down. Afterwards, the service can be closed with AT^SISC.

If “size” is not given the upload procedure is the same, except that the

AT^SISC=0 command must be executed after sending the last packet, and the URC “^SISW: x, 2” will appear afterwards to indicate the end of data transfer.

“mode”: [u)nique | a)ppend | d)elete]

“u)nique” selects the FTP Store Unique command to create a file name unique to the current directory. If the file name is assigned by the server then the “^SIS” URC will appear, indicating <urcInfoId>

2100 and the file name.

“d)elete” clears given ‘element name’.

If “mode” is omitted “replace mode” is default setting.

3. HTTP

• HTTP client URL

“http://’server’/’path’:’tcpPort’ “

“server”: FQDN or IP-address

“path”: path of file or directory

“tcpPort”: If parameter is omitted, the service connects to HTTP default port

80.

Refer to “IETF-RFC 2616”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 127

Chapter 10 – Internet Service Commands

“hcContent“

“hcContLen“

4. SMTP

• SMTP server address (string).

Length 4...256.

5. POP3

• POP3 server address (string).

Length 4...256.

Optional parameter for HTTP method “Post”.

Can be used to transfer a small amount of data. The content of this string will only be sent if “hcContLen” = 0. The maximum length of “hcContent” is 128 bytes.

To transmit a larger amount of data “hcContLen” must be set to a non-zero value.

In this case the “hcContent” string will be ignored, and data transmission from the client to the server is done with

AT^SISW

.

Mandatory parameter for HTTP method “Post”.

The content length shall be set in the header of the HTTP “Post” request before the data part is transferred.

If “hcContLen” = 0 then the data given in the “hcContent” string will be posted.

If “hcContLen” > 0 then the AT^SISW command will be used to send data from the client to the server. In this case, “hcContLen” specifies the total amount of data to be sent. The data can be sent in one or several parts. For each part, the transmission is triggered by the URC “^SISW: x, 1”, then the AT^SISW write command can be executed. Finally, the URC “^SISW: x, 2” indicates that all data have been transferred and the service can be closed with AT^SISC.

“hcUsrAgent“

“hcMethod“

“hcProp“

The user agent string must be set by the application to identify the mobile. Usually operation system and software version info is set with this browser identifier.

HTTP method specification: 0=GET, 1=POST, 2=HEAD.

Parameter for several HTTP settings.

The general format is ‘key’: <space> ‘value’ “\0d\0a”. Multiple settings can be given separated by “\0d\0a” sequences within the string.

Possible ‘key’ values are defined at HTTP/1.1 Standard RFC 2616.

“hcRedir“

“hcAuth“

This flag controls the redirection mechanism of the Multi-Tech Wireless EDGE modem acting as an HTTP client (numeric).

If the flag is set (1), the client automatically sends a new HTTP request if the server answers with a redirect code (range 30x). Default is 0 (no direction)

If set (1), this flag determines that the HTTP client will automatically answer on authentication requests from the server with the current “passwd” and “user” parameter settings. If these parameters are not specified, the Multi-Tech Wireless

EDGE modem will terminate the HTTP connection and send an indication to the

TA. Default is 0.

“smFrom“ Email sender address; i.e., “MAIL FROM” address (string).

6...256.

A valid address parameter consists of local part and domain name delimited by a

‘@’ character; e.g., “ [email protected]

”.

“smRcpt“ Recipient address of the email; i.e., “RCPT TO” address (string).

Length:

If multiple recipient addresses are to be supplied the comma character is used as delimiter to separate individual address values; e.g.,

[email protected],[email protected]

”.

“smCC“

“smSubj“

CC recipient address of the email (string).

Length:

If multiple CC recipient addresses are to be supplied, the comma character is used as a delimiter to separate address values; e.g.,

[email protected],tom.meier@somedomain. de ”.

Subject content of the email (string).

Length:

If no subject is supplied the email will be sent with an empty subject.

“smHdr“ This parameter, if set, will be appended at the end of the email header section

(string).

Length:

Hence, it serves as a generic header field parameter which allows the user to provide any email header field. It is the user’s responsibility to provide correct header fields!

String of max. 512 characters.

Example for multipart MIME messages: “Content-Type: multipart/mixed”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 128

Chapter 10 – Internet Service Commands

“smAuth“ SMTP authentication control flag (numeric).

If disabled (<srvParmValue> “0” by default), the Multi-Tech Wireless EDGE modem performs action without SMTP authentication.

If enabled (<srvParmValue> “1”), authentication procedure with the SMTP server will be performed by means of supported authentication methods, using values of

“user” and “passwd” parameters. If the Multi-Tech Wireless EDGE modem and

SMTP server are not able to negotiate an authentication mechanism supported by both parties, the Multi-Tech Wireless EDGE modem continues action without authentication.

Multi-Tech Wireless EDGE modem supports SMTP login authentication.

POP3 user command to be executed by the POP3 service (numeric).

For supported values of <srvParmValue> refer to <srvParmValue-pCmd>.

“pCmd“

“pNumber“ Optional message number argument used by the POP3 commands List (“2”),

Retrieve (“3”) and Delete (“4”). For POP3 commands see <srvParmTag> value

“pCmd”.

Length:

“pLength“

0...2

If no specific value is set in the service profile, the value “0” is assumed by default.

Maximum message length (string, optional).

0...2

32

32

– 1.

– 1

“pLength” can be used to specify the length of the message(s) to be retrieved from or deleted on the POP3 server. If no specific value is set in the service profile, the default value “0” is assumed, which means that there is no limit on the message size.

A warning will be issued inthe following cases:

• If “pNumber” >0 and a specific message to be retrieved from / deleted on the server is longer than “pLength”.

• If “pNumber” = 0 and all messages to be retrieved from / deleted on the server are longer than “pLength”.

No warning will be issued in the following cases:

• If there are no messages at all on the server.

• If the server has message(s) below and above the “pLength” specified.

In this case, the message(s) within the range of “pLength” can be successfully retrieved or deleted, but the message(s) above “pLength” remain on the server without any further notification given to the user.

• Therefore, after retrieving / deleting messages, it is recommended to check the message status on the server. This can be done by adding a further POP3 service profile using the POP3 user command List “2”.

“pDelFlag“ Flag to be used with the POP3 user command Retrieve (“3”). Specifies whether or not to delete retrieved emails on the server (optional).

For supported values of <srvParmValue> refer to <srvParmValuepDelFlag>.

<srvParmValue>

Parameter value; type and supported content depend on related <srvParmTag>.

<srvParmValue-servType>

Supported Internet service type values in <srvParmValue> for <srvParmTag> value “srvType”.

Before changing the “srvType” of an existing service profile be sure that the profile is closed. To verify the connection state of the service profile enter the read command AT^SISO. Only when <srvState>=2 is returned for this specific service profile you can change its server type. Otherwise, changing the server type would immediately deregister the service (i.e., its TCP/IP connection would be immediately shut down).

“Socket“

“FTP“

“HTTP“

“SMTP“

“POP3“

“none“

The Multi-Tech wireless modem acting as client or server (listener) for TCP, or as client for UDP. If the wireless modem is listener two service profiles are required.

The first socket profilemust be configured as listener. The second service profile will be dynamicallyassigned when a socket connection request from a remote client is incoming.

For this purpose, one service profile must be left free (= not configured withAT^SISS). An incoming socket connection request will be indicated by the”^SIS” URC, with the next free <srvProfileId> shown inside the URC as parameter <urcInfoId>. The connection request can be accepted or rejected by using AT^SISO or AT^SISC and the ID retrieved from the “^SIS”.

Multi-Tech Wireless EDGE modem acting as FTP client.

Multi-Tech Wireless EDGE modem acting as HTTP client.

Multi-Tech Wireless EDGE modem acting as SMTP client.

Multi-Tech Wireless EDGE modem acting as POP3 client.

Reset Internet service profile settings. Operation is not allowed if profile is in use; i.e., it was activated via AT^SISO.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 129

Chapter 10 – Internet Service Commands

<srvParmValue-alphabet>

Supported string parameter character set selections in <srvParmValue> for <srvParmTag> value “alphabet”.

“0“

“1“

Applicable character set is determined by current setting of AT+CSCS. Default.

International Reference Alphabet (IRA, seven bit ASCII).

<srvParmValue-pCmd>

Supported POP3 user command values in <srvParmValue> for <srvParmTag> value “pCmd”.

“1“ Status command.

This command retrieves the “drop listing” of a POP3 server. A “drop listing” consists of a single line containing the number of messages in the maildrop list followed by the total size of the maildrop list in bytes. Each drop listing will be finished by a so-called “dotline”, i.e. a new line with just a single dot.

“2“

“3“

List command.

If <srvParmTag> value “pNumber” is set to a non-zero value, the “List” command returns the

“scan listing” consisting of a single line which contains the message number and the message size in bytes if the specified message exists in the maildrop list on the POP3 server.

If no such message exists on the server than the POP3 service issues an error response to the user.

If <srvParmTag> value “pNumber” is zero, the “List” command returns a multi-line “scan listing”.

For each message on the maildrop list of the server the POP3 service returns a line containing the message number and its size in bytes. A final “dotline” will be printed at the end of the “scan listing”.

If there are no messages on the maildrop list of the server, the POP3 service returns a positive response, i.e. it doesn’t issue an error response, but the “scan listing” will be empty.

In either case, each scan listing will be finished by a so-called “dotline”; i.e., a new line with just a single dot.

Retrieve command.

If <srvParmTag> value “pNumber” is set to a non-zero value, this command retrieves the related message from the POP3 server’s maildrop list.

If no such message exists on the server the POP3 service issues an error response to the user.

It depends on the parameter “pDelFlag” if the message will be deleted from the POP3 server upon successful retrieval.

If <srvParmTag> value “pNumber” is zero, the “Retrieve” command returns all messages pending in the POP3 server’s maildrop.

If there are no messages on the maildrop list of the server the POP3 service returns with a positive response, i.e. it doesn’t issue an error response, but the returned list will be empty.

Each email will be finished by a so-called “dotline”; i.e., a new line with just a single dot.

“4“ Delete command.

<srvParmTag> value “pNumber” is set to a non-zero value, the command deletes the related message from the POP3 server’s maildrop list. In fact, the message is marked as deleted on the server and will be deleted permanently if the POP3 service command executes successfully. In case an error has occurred; e.g., network loss, the message will not be deleted on the server even though the POP3 service command has been finished.

If <srvParmTag> value “pNumber” is zero, the “Delete” command deletes all message from the

POP3 server’s maildrop list. In fact, the messages are marked as deleted on the server and will be deleted permanently if the POP3 service command executes successfully. In case an error has occurred, the messages will not be deleted on the server even though the POP3 service command has been finished.

<srvParmValue-pDelFlag>

Supported flag values in <srvParmValue> for <srvParmTag> value “pDelFlag”. Only applicable if the profile contains the POP3 user command Retrieve (“3”).

“0“

“1“

Messages will not be deleted on the server. Default.

Delete messages on the server which have been retrieved successfully.

10.2.1 Example: Configuring Socket Listener

The example assumes that a connection profile has been created as explained in Section 10.1.1 or Section 10.1.2.

Keep in mind that if the host is configured as listener another service profile must be left free to be dynamically assigned as Server when the listener receives a connection request from a remote client.

Configure the service profile 4 for use as Socket listener: at^siss=4,srvType,socket

OK at^siss=4,conId,0

OK

Select service type Socket.

Select connection profile 0. the Socket listener service. The local IP address will be dynamically assigned when the service is opened with AT^SISO.

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 130

Chapter 10 – Internet Service Commands

Open the Socket service and query the IP address dynamically assigned to the Socket listener: at^siso=4

OK at^siso?

Open the Socket service.

Query the current status of services. All service profiles are unused, except for service profile 4 which is running in listener mode, where <srvState>=3

(listening) and <socketState>=3 (LISTENER). The response also indicates the

IP address dynamically assigned to the listener.

^SISO: 0, “”

^SISO: 1, “”

^SISO: 2, “”

^SISO: 3, “”

^SISO: 4, “Socket”,”3”,”3”,”0”,”0”,”10.10.0.187:65534”,”0.0.0.0:0”

^SISO: 6, “”

^SISO: 7, “”

^SISO: 8, “”

^SISO: 9, “”

OK

10.2.2 Example: Configuring Socket Client for Calling a Socket Listener on

Another Host

The example assumes that a connection profile has been created as explained in Section 10.1.1 or Section 10.1.2.

Configure the client’s service profile 1 for calling a Socket listener on another host: at^siss=1,srvType,socket

OK at^siss=1,conId,0

Select service type Socket.

Select connection profile 0.

OKat^siss=1,address,”socktcp://10.10.0.187:65534” The service profile of the client contains the IP address and the TCP port of the remote host.

OK

10.2.3 Example: Configuring and Using FTP Download

First set up a connection profile as explained in Section 10.1.1 or Section 10.1.2. Enter at least all parameters that are mandatory for the connection profile.

Configure the service profile 1 for FTP: at^siss=1,srvType,ftp

OK at^siss=1,conId,0

OK at^siss=1,address,ftp://192.168.1.2;type=d

OK

Make an FTP connection: at^siso=1

OK

^SISR: 1, 1 at^sisr=1,1500

^SISR: 1, 50 hardware inttest software support systemtest

OK

^SISR: 1, 2 at^sisc=1

OK

Select service type FTP.

Select connection profile 0.

Specify FTP address with user and password anonymous.

Open the service.

Bearer is established, service is getting started.

Data are available.

Request to read 1500 bytes.

50 bytes are now available.

Data transfer finished. No more data available. The connection to the FTP server is closed.

Close the service.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 131

Chapter 10 – Internet Service Commands

10.2.4 Example: Configuring and Using FTP Upload

First set up a connection profile as explained in Section 10.1.1 or Section 10.1.2. Enter at least all parameters that are mandatory for the connection profile.

Configure the service profile 1 for FTP: at^siss=1,srvType,ftp

OK at^siss=1,conId,0

OK

Select service type FTP.

Select connection profile 0. at^siss=1,address,”ftpput://myname:[email protected]/upload/example.txt”

Specify FTP address with individual user name and password. The file “example.txt” shall be created on the FTP server.

OK

Make an FTP connection: at^siso=1

OK

^SISW: 1, 1 at^sisw=1,100

Open the service.

Bearer is established, service is getting started.

FTP service is ready for upload.

Client requests to send 100 bytes.

^SISW: 1, 100 The write command response confirms: 100 bytes must be transferred now.

0123456789012345678901234567890123456789012 User data are transferred.

3456789012345678901234567890123456789012345

67890123456789

OK

^SISW: 1, 1 at^sisc=1,0

^SISW: 1, 2

URC indicates that the FTP service is ready to transfer more data.

Data of the last at^sisw command are transferred to the remote host.

No more data available. The file “example.txt” shall be closed on the

FTP server. OK

Data transfer finished. The connection to the FTP server is closed.

10.2.5 Example: Sending Email over GPRS

First set up a connection profile as explained in Section 10.1.2. Enter at least all parameters that are mandatory for a GPRS profile. The example uses the connection profile ID 0 and the service profile ID 9.

Select service type SMTP. at^siss=9,srvType,”SMTP”

OK at^siss=9,alphabet,”1”

OK at^siss=9,conId,”1”

OK at^siss=9,address,”192.168.1.2”

OK at^siss=9,user,”subscriber1”

OK at^siss=9,passwd,”subscr1”

OK at^siss=9,smFrom,”[email protected]

OK at^siss=9,smRcpt,”[email protected]

OK at^siss=9,smSubj,”Meeting Request SundayMorning”

OK at^siss=9,smAuth,”1”

OK at^siss?

Choose ASCII alphabet.

Select connection profile 1.

Specify SMTP server address.

Specify sender’s user name required for SMTP authentication.

Specify password used by the sender for SMTP authentication.

Sender’s email address.

Recipient’s email address.

Enter text for subject field.

Sender name and password can be used for SMTP authentication.

To check the profile enter the AT^SISS read command. The response includes the values of all 10 connection profiles. In this example, no values are set for the profiles 0 through 8.

^SISS: 0, “svrType”, “”

^SISS: 1, “svrType”, “”

^SISS: 2, “svrType”, “”

^SISS: 3, “svrType”, “”

^SISS: 4, “svrType”, “”

^SISS: 6, “svrType”, “”

^SISS: 7, “svrType”, “”

^SISS: 8, “svrType”, “”

^SISS: 9, “svrType”, “Smtp”

^SISS: 9, “conId”, “0”

^SISS: 9, “alphabet”, “1”

^SISS: 9, “address”, “192.168.1.2”

^SISS: 9, “user”, “subscriber1”

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 132

Chapter 10 – Internet Service Commands

^SISS: 9, “passwd”, “*******”

^SISS: 9, “smFrom”, “[email protected]

^SISS: 9, “smRcpt”, “[email protected]

^SISS: 9, “smCC”, “”

^SISS: 9, “smSubj”, “Meeting Request Sunday Morning”

^SISS: 9, “smHdr”, “”

^SISS: 9, “tcPort”, “25”

^SISS: 9, “smAuth”, “1”

OK at^siso=9

OK

^SISW: 9, 1 at^sisw=9,87

^SISW: 9, 87

Open the service, i.e. start to send the email.

URC indicates that data are available for transmission.

The email to be sent has 87 bytes.

The write command response confirms that 87 bytes are available for transmission.

Good Morning everyone, we are delighted to announce our next meeting on Sunday morning.

OK at^sisc=9

OK

^SISW: 9, 2 at^siso?

Write the message text.

Close the service.

The URC confirms that all data have been sent successfully.

Use the AT^SISO command to check the connection state of the service profile 9. The response confirms that the SMTP service and the socket have been closed, 87 bytes have been transferred, no bytes received. Furthermore sender and recipient addresses are stated.

^SISO: 0, “svrType”, “”

^SISO: 1, “svrType”, “”

^SISO: 2, “svrType”, “”

^SISO: 3, “svrType”, “”

^SISO: 4, “svrType”, “”

^SISO: 6, “svrType”, “”

^SISO: 7, “svrType”, “”

^SISO: 8, “svrType”, “”

^SISO: 9, “Smtp”,”2”,”1”,”87”,”0”,”10.10.0.101:5760”,”192.168.1.2:25”

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 133

Chapter 10 – Internet Service Commands

10.3 AT^SISO Internet Service Open

Description: The AT^SISO write command starts the Internet session configured by the service profile. If the service open successfully, the URCs ^SISR and ^SISW will trigger the action to follow, either writing data with AT^SISW of reading data with AT^SISR. If the

“^SISW” and “^SISR” URCs notify that no data is available at all, or that a data transfer has been successful, the service can be closed with AT^SISC. If an error occurs after opening or while using a service then the URC type “^SIS” described below will be delivered.

In any case, an opened service must be finished by sending the Close command

AT^SISC. This applies no matter whether the service has been completed successfully

(all data transmitted) or entered an error state (e.g., indicated by the “^SIS” URC). It is also necessary when a service, such as POP3 or FTP, has already closed automatically after successful data transfer and entered <srvState> “2”.

The AT^SISO read command requests the status of all Internet service profiles. One line is issued for every Internet service profile. Information following <srvParmTag> value “srvType” is issued only if “srvType” was given a valid value via AT^SISS. The read command can be used any time during operation or after closing a service. In the latter case the response indicates the state of the last event related to a specific service profile. It will be updated only when the same service profile is used again.

Test Command Syntax: AT^SISO=?

Response:

Read Command Syntax: AT^SISO?

Response:

OK

^SISO: <srvProfileId>, <srvParmTag>value “srvType” [, <srvState>, <socketState>,

<rxCount>, <txCount>, <locAddr>, <remAddr>]

OK

Write Command Syntax: AT^SISO=<srvProfileId>

Response: OK

ERROR

Unsolicited Result Code:

+CME ERROR: <err>

Indicates the current state of the Internet service.

^SIS: <srvProfileId>, <urcCause>[, [<urcInfoId>][, <urcInfoText>]]

The URC may appear if an error occurs, for example after opening an Internet service with AT^SISO or any time during operation. The URC also indicates a request for a mobile terminated Internet service client connection, or a failure if a mobile terminated request is rejected. Furthermore, the URC may deliver an information element resulting from a specific command given in the service profile.

The precise <urcInfoText> related to a <urcInfoId> varies greatly depending on the used service, the scenario and the implementation of the remote server. A list of possible causes can be found in Section 10.7, Info. Elements Related to Internet Service URCs.

Parameter Descriptions:

<srvProfileId>

<srvProfileId> 0 ... 9 specified with AT^SISS.

<srvState>

Internet service state identifier.

“”

2

Service profile is unused.

Service profile resources are allocated; i.e., at least the service type has been set

3

4

5

(parameter <srvParmTag>, value “srvType” of AT^SISS). The service is not opened.

Connecting: State after opening a service with AT^SISO where the connection is being established.

If connection setup is successful the service proceeds to the state “4” (Connected) and one of the URCs “^SISW” and “^SISR” may follow. If connection setup is not successful, the “^SIS” may appear.

In the case of SMTP, the service will not enter <srvState>=3 until the host has written the first data packet with AT^SISW.

If the service profile is configured as Socket listener, then the listener always stays at

<srvState>=3 (listening) and <socketState>=3 (LISTENER), while the <srvState> and

<socketState> of the dynamically assigned service profile may change. See examples in Section 10.3.1.

Connected: Socket connection valid.

Closing: Socket connection releasing. The Closing state is reached after sending the

AT^SISC command or after a service has closed automatically, such as FTP download or POP3. In the latter case, it is necessary to send the AT^SISC command even though the FTP download or POP3 service has already entered <srvState> “2”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 134

Chapter 10 – Internet Service Commands

<socketState>

Socket state identifier.

1

2

3

4

Socket not assigned; i.e., no TCP/UDP connection active.

Socket assigned as CLIENT.

Socket assigned as LISTENER.

Socket assigned as SERVER.

<rxCount>

Number of bytes received via AT^SISR since last successful AT^SISO write command.

<txCount>

Number of bytes sent via AT^SISW since last successful AT^SISO write command.

<locAddr>

Local IP address in dotted-four-byte format and TCP port, separated by colon; e.g., “192.60.10.10:80”.

<remAddr>

Remote IP address in dotted-four-byte format or evaluated DNS name and TCP port, separated by colon; e.g.,

“192.60.10.10:80”.

<urcCause>

URC cause identifier.

0 An error has occurred after opening or while using an Internet service.

Error number is presented via <urcInfoId>, optionally additional information may be supplied via <urcInfoText>.

1

2

Indicates that an open socket listener service is receiving a connection request from a remote client.

The incoming socket connection is dynamically assigned to the next free Internet service profile. In this case, the parameter <urcInfoId> inside the “^SIS”

URC equals the <srvProfileId> of the dynamically assigned service profile.

This ID shall be used to accept the connection request with AT^SISO or to reject it with AT^SISC.

The connection status may be requested by using the AT^SISO read command.

Among other details, the response indicates the IP address of the remote client (parameter <remAddr>). This may be helpful to decide whether to accept or reject the request.

Incoming Socket service client connection has failed.

The client request was rejected automatically because no free Internet service profile was available.

3 HTTP only: Indicates that the message delivered by the "^SIS" URC is provided for information only, it is not an error. For details refer to Info URCs in Section 10.7.3, URC

Information Elements Related to HTTP Service.

Example: ^SIS: 2, 3, 2200, "HTTP Redirect to:192.168.1.3:800//products/info/"

<urcInfoId>

Information identifier related to <urcCause>.

See Section 10.7, Information Elements Related to Internet Service URCs for further detail. As stated above, if a

Socket connection request from a remote client is received the <urcInfoId> equals the <srvProfileId> of the dynamically assigned free service profile.

<urcInfoText>

Information text related to <urcCause>. See Section 10.7, Info. Elements Related to Internet Service URCs.

10.3.1 Example: Accepting/Rejecting Socket Connection Request from Remote

Client

Host 1 configured as Socket listener with IP address 10.10.0.187 at port 65534 is receiving a connection request from the remote client 10.10.0.185 (at port 1024). The example assumes that connection and service profiles have been created as stated earlier.

Start the Socket service in listener mode, then query the IP address dynamically assigned to the Socket listener: at^siso=4 at^siso?

Host 1 opens the Socket service.

Query the current status of all services. All service profiles are unused, except for service profile 4 which is running in listener mode, where

<srvState>=3 (listening) and <socketState>=3 (LISTENER). The response also indicates the IP address dynamically assigned to the listener. The listener’s access data (IP address and TCP port number) shall be passed on to the client.

^SISO: 0, “”

^SISO: 1, “”

^SISO: 2, “”

^SISO: 3, “”

^SISO: 4, “Socket”,”3”,”3”,”0”,”0”,”10.10.0.187:65534”,”0.0.0.0:0”

^SISO: 6, “”

^SISO: 7, “”

^SISO: 8, “” ^SISO: 9, “”

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 135

Chapter 10 – Internet Service Commands

Indication of incoming Socket connection request:

^SIS: 4, 1, 0 The URC indicates that the listener configured on service profile 4 is receiving a Socket connection request (<urcCause>=1) from the remote client. The last URC parameter <urcInfoId> represents the at^siso?

ID of the dynamically assigned service profile, here 0.

Query the current status of services.

^SISO: 0, “Socket”,”2”,”4”,”0”,”0”,”10.10.0.187:0”,”10.10.0.185:1024” Indication on host 1 that the connection request from the remote client has been dynamically assigned to service profile 0 which is set to

Server mode (<socketState>=4).

^SISO: 1, “”

^SISO: 2, “”

^SISO: 3, “”

^SISO: 4, “Socket”,”3”,”3”,”0”,”0”, “10.10.0.187:65534”,”0.0.0.0:0”

^SISO: 6, “”

^SISO: 7, “”

^SISO: 8, “”

^SISO: 9, “”

OK

Host 1 accepts the Socket connection request: at^siso=0 Host 1 accepts the connection request, where 0 is the ID of the dynamically assigned service profile.

OK

^SISW: 0, 1 The URC indicates that data transmission to the remote client is possible. If the remote client has already sent some data the additional URC ^SISR: 0,1 is displayed.

Query the current status of services. at^siso?

^SISO: 0, “Socket”,”4”,”4”,”0”,”0”,”10.10.0.187:65534”,”10.10.0.185:1024” The socket connection between host 1 and remote client is successfully established.

^SISO: 1, “”

^SISO: 2, “”

^SISO: 3, “”

^SISO: 4, “Socket”,”3”,”3”,”0”,”0”,”10.10.0.187:65534”,”0.0.0.0:0”

^SISO: 6, “”

^SISO: 7, “”

^SISO: 8, “”

^SISO: 9, “”

OK

Host 1 rejects the Socket connection request: at^sisc=0 Host 1 rejects the connection request, where 0 is the ID of the dynamically assigned service profile.

OK at^siso?

^SISO: 0, “”

Query the current status of services.

The dynamically assigned service profile is free again. The Socket listener stays at <srvState>=3 (listening) and <socketState>=3

(LISTENER).

^SISO: 1, “”

^SISO: 2, “”

^SISO: 3, “”

^SISO: 4, “Socket”,”3”,”3”,”0”,”0”,”10.10.0.187:65534”,”0.0.0.0:0”

^SISO: 6, “”

^SISO: 7, “”

^SISO: 8, “”

^SISO: 9, “”

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 136

Chapter 10 – Internet Service Commands

10.4 AT^SISC Internet Service Close

Description: The AT^SISC write command performs all necessary action to release all properties activated by AT^SISO.

Test Command Syntax: AT^SISC=?

Response:

Write Command Syntax: AT^SISC=<srvProfileId>[, <closeMode>]

Response:

OK

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<srvProfileId>

<srvProfileId> 0 ... 9 specified with AT^SISS.

<closeMode>

Specifies the mode to close an Internet connection. The selected mode’s effect depends on the type of service.

0

1

Graceful. Default.

Immediate

10.4.1 Effect of Parameter <closeMode>

Service

Type

Graceful

Socket TCP/IP connection will be closed after the transmission of remaining data has completed. upload:

The “OK” response following the command

AT^SISC=<srvProfileId>,<close-Mode> indicates that the FTP service has accepted the close command - it DOES NOT indicate the successful completion of the FTP service close procedure.

HTTP

SMTP

Successful completion will be indicated by the appropriate URC “^SISW: x,2”. The host application can force a service shutdown

(<closeMode>= 1) if the aforementioned URC doesn’t occur after a user defined timeout.

FTP download:

Same as <closeMode> immediate: TCP/IP connection is closed immediately.

TCP/IP connection is closed immediately.

The SMTP service sends some “closing” commands which are necessary to mark the email as successfully sent on the server. The service enters the <srvState> “Closing” and remains in this state until the final protocol exchange with the SMTP server has completed.

The “OK” response following the command

AT^SISC=<srvProfileId>,<close-Mode> indicates

Immediate

TCP/IP connection will be closed immediately. All remaining data are lost.

TCP/IP connection is closed immediately.

All remaining data is lost.

TCP/IP connection is closed immediately.

The SMTP service closes the TCP/IP connection immediately. Email transfer is aborted. This mode can be used to cancel an SMTP operation.

POP3 that the SMTP service has accepted the close command - it DOES NOT indicate the successful completion of the SMTP service close procedure.

Successful completion will be indicated by the appropriate URC “^SISW: x,2”. The host application can force a service shutdown

(<close-Mode>= 1) if the aforementioned URC doesn’t occur after a user defined timeout.

Same as <closeMode> immediate: The TCP/IP connection is closed immediately.

The TCP/IP connection is closed immediately.

Once the last service has been closed the bearer shuts down after a timeout of 20 seconds (i.e., the connection profile GPRS0 or CSD is closed). If a service related to the same connection profile starts up again within this time frame, the bearer will not be closed, but started again. This speeds up the handling of several service requests. Within this time frame it is neither possible to change the bearer type (from GPRS to CSD or vice versa) nor to start a service based on a different connection profile.

To disconnect the bearer before the timeout expires the command AT+CGATT=0 can be used in the case of

GPRS and ATH in the case of CSD.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 137

Chapter 10 – Internet Service Commands

10.5 AT^SISR Internet Service Read Data

Description: AT^SISR write command triggers reading data via the Internet service configured with

AT^SISS.

The Multi-Tech Wireless EDGE modem returns the amount of data which can be transferred:

• <cnfReadLength> value equal 0 indicates that the Multi-Tech Wireless EDGE modem failed to enter online data mode. Details about the cause of failure is available using

AT+CEER.

• <cnfReadLength> value greater than 0 indicates that the Multi-Tech Wireless EDGE modem switches into online data mode to transfer the given number of bytes.

A URC “^SISR: <srvProfileId>, <urcCauseId>[, <remainUdpPacketLength>]" will be issued if

• data is available after opening an Internet service or

• less data was confirmed (in <cnfReadLength>) than requested (with

<reqReadLength>) during the last “Read Data” operation and new data is available.

This mechanism eliminates the need to poll for fresh data and frees the TA for other tasks.

Test Command Syntax: AT^SISR=?

Response:

Response:

OK

Write Command Syntax: AT^SISR=<srvProfileId>, <reqReadLength>

^SISR: <srvProfileId>, <cnfReadLength> Number of data bytes are sent as specified by

<cnfReadLength>

OK

ERROR

+CME ERROR: <err>

Unsolicited Result Code: ^SISR: <srvProfileId>, <urcCauseId><urcCauseId>[, <remainUdpPacketLength>]

Parameter Descriptions:

Data availability status of the Internet service configured with AT^SISS

<srvProfileId>

<srvProfileId> 0 ... 9 specified with AT^SISS.

<reqReadLength>

Requested number of data bytes to be read via the Internet service configured in <srvProfileId>. has changed.

1...1500

<cnfReadLength>

Confirmed number of data bytes to be read via the Internet service configured AT^SISS. This number may be less or equal to the value requested with <reqReadLength>. 0 value indicates that no data can be read.

<urcCauseId>

Indicates whether or not data is available for reading with AT^SISR.

0 No data available for reading

1 New data is available and can be read by sending AT^SISR. While the service is open, this URC appears each time when new data is available again. This eliminates the need to poll for fresh data.

2 Data transfer has been finished (all data read) and the service can be closed with AT^SISC.

<remainUdpPacketLength>.

Optional third parameter of the "^SISR" URC displayed only if the Socket service uses UDP.

The UDP protocol requires that data are received in the same order that they were sent from the remote host.

Consequently, the reception of each datagram must be completed before the next datagram can be received.

This may be a problem if the buffer of the host application is limited and not designed to handle the maximum packet size of 1500 bytes. To compensate this, the host is advised to request, via <reqReadLength>, an amount less or equal its maxmimum buffer capacity and wait for the resulting "^SISR" URC with parameter

<remainUdpPacketLength>. The benefit of this approach is that the host may properly receive all parts of a UDP datagram, as after each received data part the number of remaining bytes is synchronized, until reading the datagram is finished.

If the currently read datagram is smaller than the number of bytes requested by the host the

<remainUdpPacketLength> parameter is omitted.

0 Indicates that all bytes of the current UDP datagram are read.

1...(max. data size)-1 Indicates that the currently read UDP datagram is not yet complete. The displayed value is the remaining number of bytes.

<remainUdpPacketLength> is unequal 0 until reading all parts of the current datagram is finished.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 138

Chapter 10 – Internet Service Commands

10.5.1 Example: Socket Host Reads Small Amounts of UDP Data Packets

This section applies only to the Socket service using the UDP protocol. The example shows how to read UDP packets if the buffer of the host application can handle only a few bytes. There are two datagrams available for reading.

Buffer size: 6 bytes

Datagram A = 18 bytes (content "THIS_IS_DATAGRAM_A")

Datagram B = 3 bytes (content "NEW")

^SISR: 0,1 Service profile 0 is configured for Socket service and UDP. The URC notifies host that data are available for reading.

The host requests to read 6 bytes.

The first 6 bytes of datagram A are confirmed and transmitted. Another 12 bytes are still available. at^sisr=0,6

^SISR: 0,6,12

THIS_I

OK at^sisr=0,6

^SISR: 0,6,6

S_DATA

OK at^sisr=0,6

^SISR: 0,6,0

GRAM_A

OK at^sisr=0,6

The host requests to read the next part of 6 bytes.

The next 6 bytes of datagram A are confirmed and transmitted. Another

6 bytes are still available.

The host requests to read the next part of 6 bytes.

Last part of datagram A was received, no remainder is left.

^SISR: 0,3

NEW

OK

Again, the host requests to read 6 bytes. This time, the URC refers to datagram B which has only 3 bytes. As the read datagram is smaller than the size requested by the host, the

URC does not include the <remainUdpPacketLength>.

3 bytes are confirmed and transmitted. Datagram B was properly received.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 139

Chapter 10 – Internet Service Commands

10.6 AT^SISW Internet Service Write Data

Description: AT^SISW write command triggers writing data via the Internet service configured with AT^SISS.

Multi-Tech Wireless EDGE modem returns the amount of data which can be written:

• <cnfWriteLength> value equal 0 indicates that the Multi-Tech Wireless EDGE modem failed to enter online data mode. Details about the cause of failure is available using AT+CEER.

• <cnfWriteLength> value greater than 0 indicates that the Multi-Tech Wireless EDGE modem switches into online data mode to transfer the given number of bytes.

A URC “^SISW: <srvProfileId>, <urcCauseId>” will be issued if

• the Multi-Tech Wireless EDGE modem is capable to send data after opening the Internet service or

• less transmission buffer space was confirmed (in <cnfWriteLength>) than requested (with

<reqWrite-Length>) or contained data has been sent via the Internet service.

• or all available data has been transferred.

This mechanism is designed to avoid polling for free transmission buffer space and, thus, free the

TA for other tasks.

Test Command Syntax: AT^SISW=?

Response: OK

Write Command Syntax: AT^SISW=<srvProfileId>, <reqWriteLength>

Response: ^SISW: <srvProfileId>, <cnfWriteLength> Number of data bytes are expected as specified by <cnfWriteLength>

OK

ERROR

+CME ERROR: <err>

Unsolicited Result Code:

^SISW: <srvProfileId>, <urcCauseId>

Data availability status of the Internet service configured with AT^SISS has changed.

Parameter Descriptions:

<srvProfileId>

<srvProfileId> 0 ... 9 specified with AT^SISS.

<reqWriteLength>

Requested number of data bytes to be transmitted via the Internet service configured with AT^SISS.

1...1500

<cnfWriteLength>

Confirmed number of data bytes to be transmitted via the Internet service configured in <srvProfileId>. This number may be less or equal to the value requested with <reqWriteLength>. 0 value indicates that no data can be written.

<urcCauseId>

Indicates whether or not data are available for transfer with AT^SISW.

0

1

2

No data available for writing with AT^SISW.

New data can be written via AT^SISW.

In the case of Socket, FTP download, HTTP: Data transfer has been finished and Internet service can be closed via AT^SISC.

In the case of FTP upload and SMTP: To indicate successful transmission, the URC “^SISW: x,2” is sent after the service was gracefully closed. If the FTP upload or SMTP service is closed immediately the URC will not be sent.

Note

The AT^SISW write command must be terminated only with the ASCII character set with ATS3. The factory default for S3 is #13 (Carriage Return). Do not send any further characters after the S3 end-of-line identifier, until the response "^SISW" is received. This is necessary to avoid that any characters related to the AT command can be interpreted as being part of the data stream to be transferred.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 140

Chapter 10 – Internet Service Commands

10.7 Information Elements Related to Internet

Service URCs

This section describes the information elements which may be presented by the “^SIS” URC after opening an

Internet service. See also AT^SISO.

The tables contain the <urcInfoId> and, if applicable, a specific <urcInfoText>. If marked with *) the precise text related to a <urcInfoId> varies greatly depending on the scenario and the implementation of the remote server. In these cases, only a brief explanation of the scenario can be found in the column “Description”.

10.7.1 URC Information Elements Related to the Service Application

The following table lists URC information elements which may be returned by all supported services. It should be noted that TCP/IP socket problems may occur in all Internet service connections (Socket, FTP, HTTP, POP3 or SMTP).

<urcInfoId> <urcInfoText> Description

URC Information Elements Returned by the TCP/IP socket

2 Socket error: Invalid socket descriptor

3

4

5

6

7

8

9

Socket error: Bad access specified

Socket error: Invalid operation

Socket error: No free socket descriptors

Socket error: The operation would block

Socket error: A previous attempt at this operation is still ongoing

Socket error: Socket is not bound

Socket error: The supplied buffer is too small/large

19

20

21

22

23

24

25

10

11

12

13

14

15

16

17

18

Socket error: Flags not supported

Socket error: Operation not supported

Socket error: The address is already in use

Socket error: The network is unavailable

Socket error: An established connection was aborted

Socket error: Remote host has reset the connection

Socket error: No buffer space available

Socket error: The socket is already connected

Socket error: The socket is not connected

Socket error: Socket has been shut down

Socket error: Connection timed out

Socket error: Remote host has rejected the connection

Socket error: Remote host is unreachable

Socket error: An unexpected error occurred

DNS error: Host not found

DNS error: An error occurred that may be transient; a further attempt may succeed.

26 DNS error: An unrecoverable error occurred

General URC Information Elements

46

47

Fatal: The service has detected an unknown error

*)

48

49

Fatal: No memory is available for service action

Fatal: Service hs detected an internal error.

Indicates that the remote service has closed the connection. The host shall close the service.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 141

Chapter 10 – Internet Service Commands

10.7.2 URC Information Elements Related to FTP Service

<urcInfoId> <urcInfoText>

100

101

FTP Server rejects session.

FTP Server rejects USER command.

102

103

FTP Server rejects PASS command.

FTP Server rejects PASV command or client can’t detect remote IP address.

104

105

106

FTP Server rejects requested client action.

The given path segment is wrong.

*)

Description

107

2100

*)

FILE: <filename>

The FTP client requests the file size from the server before starting the download.

During transmission phase the client adds the bytes which are sent via serial line. After transmission is done the client compares the amount of bytes transferred via serial line and socket.

The FTP client detects a difference between the received bytes via socket and the requested bytes via the SIZE command.

File name assigned by FTP server if mode=u is used.

10.7.3 URC Information Elements Related to HTTP Service

The HTTP service uses different <urcCause> values within the "^SIS" URC: <urcCause>=0 marks an Error

URC, <urcCause>=3 marks an Info URC.

<urcInfoId> <urcInfoText>

Error URCs

200

201

202

HTTP-ERR: Not connected - cannot send request

HTTP-ERR: failed on sending request

<HTTP Response Str>

203

<HTTP Response Str>

HTTP-ERR: Service unavailable

HTTP-ERR: Redirect failed - too many redirects

HTTP-ERR: Redirect failed - not allowed

HTTP-ERR: Redirect failed - location missing

204 HTTP-ERR: auth failed - user name or password missing

HTTP-ERR: auth failed - user name or password wrong

HTTP-ERR: Authority required for this URL

HTTP-ERR: No access to this URL allowed

Info URCs

2200

2201

HTTP Redirect to: <Host>:<Port> <Path>

HTTP Response <Response code>

Example: ^SIS: 2,3,2201, “HTTP Response:

HTTP/1.1

200 OK”

Description

Client error

Server error

Max. number of allowed redirects: 6

10.7.4 URC Information Elements Related to POP3 Service

<urcInfoId> <urcInfoText> Description

300 *) Indicates that the POP3 User Command could not be executed successfully.

10.7.5 URC Information Elements Related to SMTP Service

<urcInfoId> <urcInfoText> Description

400 *) Indicates that the SMTP service could not be executed successfully..

*) Text varies depending on scenario.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 142

Chapter 11 – GPRS Commands

Chapter 11. GPRS Commands

This chapter describes AT Commands that a TE (Terminal Equipment) may use to control the Multi-Tech wireless modem acting as GPRS Mobile Termination (MT). Please use “Using GPRS AT commands (Examples)” as a first guidance.

11.1 AT+CGACT PDP Context Activate or Deactivate

Description: The test command is used for requesting information on the supported PDP context activation states.

The read command returns the current activation states for all the defined PDP contexts.

The write command is used to activate or deactivate the specified PDP context(s). After the command has completed, the MT remains in V.250 command state. If any PDP context is already in the requested state, the state for that context remains unchanged. If the MT is not

GPRS attached when the activation form of the command is executed, the MT first performs a

GPRS attach and then attempts to activate the specified contexts. If no <cid>s are specified the activation/deactivation form of the command activates/deactivates all defined contexts.

Test Command Syntax: AT+CGACT=?

Response: +CGACT: (list of supported <state>s)

OK

Read Command Syntax: AT+CGACT?

Response: +CGACT: <cid>, <state>

[+CGACT:

...

OK

Write Command Syntax: AT+CGACT=[<state>[, <cid>[, <cid>]]]

Response: OK

ERROR

+CME

Parameter Descriptions:

<state>

Indicates the state of PDP context activation.

0

1 deactivated activated. Default.

<cid>

PDP Context Identifier is a numeric parameter which specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context related commands.

1...2

Notes:

• ATH will deactivate any PDP context.

• If the MT is in dedicated mode, the write command returns “+CME ERROR: operation temporary not allowed”.

• A maximum of 2 contexts can be activated at the same time, no matter on which interface. Trying to activate more than 2 contexts will cause “+CME ERROR: operation temporary not allowed”. Note that, depending on the provider, the number of activated contexts may be further restricted.

Remember that contexts may be activated implicitly by using the ATD*98# or ATD*99# GPRS compatibility commands without specifying a <cid>.

• If an activated context will be deactivated without using the command AT+CGACT, then the result code “NO

CARRIER” will be issued to indicate the context deactivation. This happens for example if the context deactivation is forced by the network or if deactivation results from a network deregistration with AT+COPS=2.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 143

Chapter 11 – GPRS Commands

11.2 AT+CGANS Manual Response to a Network

Request for PDP Context Activation

Description: The write command requests the MT to respond to a network request for GPRS PDP context activation which has been signaled to the TE by the RING or CRING unsolicited result code. The <response> parameter allows the TE to accept or reject the request.

Test Command Syntax: AT+CGANS=?

Response: +CGANS: (list of supported <response>s), (list of supported <L2P>s)

OK

Write Command Syntax: AT+CGANS=[<response>[, <L2P>[, <cid>]]]

Response: CONNECT

NO CARRIER

ERROR

+CME ERROR

Parameter Descriptions:

<response>

0

1

<L2P>

<cid>

The request is rejected and the MT returns OK to the TE. Default.

Accept and request that the PDP context be activated

A string parameter which indicates the layer 2 protocol to be used (see AT+CGDATA command).

A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

Note:

If <response> is 1, the following procedure is followed by the MT:

If the <L2P> parameter value is unacceptable to the MT, the MT will return an ERROR or +CME ERROR response. Otherwise, the MT issues the intermediate result code CONNECT and enters V.250 online data state.

A <cid> may be specified for use in the context activation request.

During the PDP startup procedure the MT has the PDP type and the PDP address provided by the network in the

Request PDP context activation message. If this is in conflict with the information provided by a specified <cid>, the command will fail. There will be no conflict, if the PDP type matches exactly and the PDP address given by the context definition for <cid> is empty or matches exactly with the address specified with the network PDP context activation message.

The context will be activated using the values for PDP type and address provided by the network, together with all other information found in the PDP context definition. An APN may or may not be required, depending on the application.

If no <cid> is given or if there is no matching context definition, the MT will attempt to activate the context using the values for PDP type and address provided by the network. The other parameters will be set to their default values

(see AT+CGDCONT).

If activation is successful, data transfer may proceed.

After data transfer is complete, and the layer 2 protocol termination procedure has completed successfully, the

V.250 command state is reentered and the MT returns the final result code OK.

In the event of an erroneous termination or a failure to start up, the V.250 command state is re-entered and the MT returns the final result code NO CARRIER, or if enabled, +CME ERROR. Attach, activate and other errors may be reported. It is also an error to issue the AT+CGANS command when there is no pending network request.

The command may be used in both normal and modem compatibility modes.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 144

Chapter 11 – GPRS Commands

11.3 AT+CGATT GPRS Attach or Detach

Description: The test command is used for requesting information on the supported GPRS service states.

The

The write command is used to attach the MT to, or detach the MT from the GPRS service. After the command has completed, the MT remains in V.250 command state. If the MT is already in the requested state, the command is ignored and the OK response is returned. Any active PDP

Test Command:

Response:

Read Command:

Response:

Write Command:

Response: contexts will be automatically deactivated when the attachment state changes to detached.

AT+CGATT=?

+CGATT: (list of supported <state>s)

OK

AT+CGATT?

+CGATT: <state>

OK

AT+CGATT=[<state>]

OK

ERROR

+CME ERROR

Parameter Descriptions:

<state>

Indicates the state of GPRS attachment.

0

1 detached attached. Default.

Notes:

• If the MT is in dedicated mode, write command returns “+CME ERROR: operation temporary not allowed”.

• When the module is GPRS attached and a PLMN reselection occurs to a non-GPRS network or to a network where the SIM is not subscribed to for using GPRS, the resulting GMM (GPRS mobility management) state according to GSM 24.008 is REGISTERED/NO CELL, meaning that the read command will still show <state>=1.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 145

Chapter 11 – GPRS Commands

11.4 AT+CGAUTO Automatic Response to a

Network Request for PDP Context Activation

Description: The test command returns the values of <n> supported by the MT as a compound value.

The the receipt of a Request PDP Context Activation message from the network. It also provides control over the use of the V.250 basic commands ATS0, ATA and ATH for handling network requests for PDP context activation.

Test Command Syntax: AT+CGAUTO=?

Response: +CGAUTO: (list of supported <n>s)

OK

Read Command Syntax: AT+CGAUTO?

Response: +CGAUTO: <n>

OK

Write Command Syntax: AT+CGAUTO=[<n>]

Response: OK

ERROR

+CME ERROR

Parameter Descriptions:

<n>

0

1

3

Disable automatic response for network requests for GPRS PDP context activation. GPRS network requests are manually accepted or rejected by the AT+CGANS command.

Enable automatic response for network requests for GPRS PDP context activation. GPRS requests are automatically accepted according to the description below.

Modem compatibility mode. The automatic acceptance of both GPRS and incoming CSD calls is controlled by the ATS0 command. Manual control uses the ATA and ATH commands, respectively, to accept or reject GPRS network requests or incoming CSD calls.

Notes:

• It is allowed to have different AT+CGAUTO settings on different interfaces.

• When the AT+CGAUTO=0 command is received, the MT will not perform a GPRS detach if it is attached.

Subsequently, when the MT announces a network request for PDP context activation by issuing the URC RING or CRING, the TE may manually accept or reject the request by issuing the AT+CGANS command or may simply ignore the network request.

• When the AT+CGAUTO=1 command is received, the MT will attempt to perform a GPRS attach if it is not yet attached. Failure will result in ERROR or, if enabled +CME ERROR being returned to the TE. Subsequently, the

MT announces a network request for PDP context activation by issuing the URC RING to the TE, followed by the intermediate result code CONNECT. The MT then enters V.250 online data state and follows the same procedure as it would after having received a +CGANS=1 with no <L2P> or <cid> values specified.

• If a GPRS attach will be initiated by this command and the MT is not able to attach for more than 385 seconds

(timer T3310 expired), command returns with “ERROR” or “+CME ERROR: unknown”, but MT is still trying to attach and the requested automatic mode <n> is in use.

• If a network request for PDP context activation is answered automatically and if another AT command is issued at the same time on the same interface, then this AT command is not executed. Any response belongs to the automatic context activation procedure. If the AT command which caused the collision was a circuit switched data call, the CONNECT response does not belong to this data call but to the GPRS. This can be detected if

ATX is not set to 0. CS data call will issue CONNECT <text>, GPRS will issue CONNECT only.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 146

Chapter 11 – GPRS Commands

11.5 AT+CGDATA Enter Data State

Description: The test command is used for requesting information on the supported layer 2 protocols to be used between the TE and MT.

The write command causes the MT to perform all actions which are necessary to establish communication between the TE and the network using one or more GPRS PDP types. This may include performing a GPRS attach and one or more PDP context activations. Commands following the AT+CGDATA command in the AT command line will not be processed by the MT.

If no <cid> is given or if there is no matching context definition, the MT will attempt to activate the context with PDP type IP and all other context parameters set to their default values (see

AT+CGDCONT, AT+CGQREQ, AT+CGQMIN).

If the <L2P> parameter is omitted, the layer 2 protocol is unspecified and PPP will be used.

If the write command is successful, the MT issues the intermediate result code CONNECT and enters V.250 online data state.

After data transfer is complete and the layer 2 protocol termination procedure has completed successfully, the command state is reentered and the MT returns the final result code OK.

If the <L2P> parameter value is unacceptable to the MT, the MT returns ERROR or +CME

ERROR.

In the event of erroneous termination or a failure to start up, the command state is reentered and the MT returns NO CARRIER, or if enabled +CME ERROR.

Test Command Syntax: AT+CGDATA=?

Response: +CGDATA: (list of supported <L2P>s)

OK

Write Command Syntax: AT+CGDATA=[<L2P>[, <cid>[, <cid>[,... ]]]]

Response: CONNECT

NO CARRIER

ERROR

+CME ERROR

Parameter Descriptions:

<L2P>

Layer 2 protocol to be used between the TE and MT.

“PPP“ layer 2 protocol PPP. Default.

<cid>

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands.

1...2

Notes:

• If the MT is in dedicated mode, write command returns “+CME ERROR: operation temporary not allowed”.

• It is possible to leave the GPRS data mode and enter the command mode by using the V.250 command +++.

By using the command AT+CGDATA again, the data mode is reentered. Which context is used to return to data mode, depends on the supplied parameter <cid>.

If no <cid> is specified, this is equivalent to using the V.250 command ATO, which is usable for GPRS connections too. In this case the first context will be used, which is active and already in data mode since it has been activated.

It is possible to use AT+CGDATA to enter the data mode for a context, which is not yet in data mode since it has been activated. With ATO this is not possible.

11.5.1 Automatic Deactivation of PDP Context During Dial-up PPP

When using the AT+CGDATA write command or ATD*99# or ATD*98# the MT issues the intermediate result code CONNECT and enters V.250ter online data state. In V.250 online data state, first some LCP protocol exchange between MT and TE is performed to set up the PPP link. After successfully establishing the PPP link, the MT performs the PDP context activation procedure if the context is not already activated. As a result, the MT is in a “PDP context activated” state within the PLMN, the PPP link is established on the mobile side and the mobile is ready for IP data transfer.

If the TE wants to close the LCP link the MT may perform an LCP termination request procedure on PPP level.

After this LCP termination procedure the MT deactivates the PDP context automatically and the MT returns to V.250 command mode and issues the final result code NO CARRIER.

During the implicit PDP context deactivation procedure after LCP termination the TE may change into V.250 command state (e.g., by using +++ or by toggling DTR if AT&D is set to 1) before the result NO CARRIER occurs.

In this case the application should not try to deactivate the PDP context by using the commands AT+CGACT or ATH. If DTR is configured to disconnect data connections (AT&D2), then the application should not toggle

DTR during the implicit PDP context deactivation and before “NO CARRIER” is received.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 147

Chapter 11 – GPRS Commands

11.6 AT+CGDCONT Define PDP Context

Description: The test command returns supported values as a compound value.

The read command returns the current settings for each defined PDP context.

write command specifies the parameters for a PDP context identified by the context identifier <cid>. The number of contexts that may be in a defined state at the same time is given by the range returned by the test command. A special form of the write command

(AT+CGDCONT=<cid>) causes the values for context <cid> to become undefined.

Test Command Syntax: AT+CGDCONT=?

Response: +CGDCONT: (range of supported<cid>s), <PDP_type>, , , (list of supported <d_comp>s),

(list of supported<h_comp>s)

OK

ERROR

+CME

Read Command:

Response:

AT+CGDCONT?

+CGDCONT : <cid>, <PDP_type>, <APN>, <PDP_addr>, <d_comp>, <h_comp>]

[+CGDCONT : ...]

OK

ERROR

+CME

Write Command:

ERROR

AT+CGDCONT=[<cid>[, <PDP_type>[, <APN>[, <PDP_addr>[, <d_comp>[,

<h_comp>]]]]]]

OK Response:

ERROR

+CME

Parameter Descriptions:

<cid>

PDP Context Identifier

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands.

1...2

<PDP_type>

Packet Data Protocol Type

Specifies the type of the packet data protocol.

“IP“ Internet Protocol (IETF STD 5)

<APN>

Access Point Name

The logical name that is used to select the GGSN or the external packet data network. If the value is null or omitted, then the subscription value will be requested.

<PDP_addr>

Packet Data Protocol Address

Identifies the MT in the address space applicable to PDP (e.g., IP V4 address for PDP type IP). If the value is null or omitted, then a value may be provided by the TE during the PDP startup procedure or, failing that, a dynamic address will be requested.

<d_comp>

Data Compression

Controls the PDP data compression (applicable for Subnetwork Dependent Convergence Protocol (SNDCP) only) 3GPP TS 44.065

0 off

<h_comp>(num)

Header Compression

Controls the PDP header compression 3GPP TS 44.065, 3GPP TS 25.323

0

1 off (Default) on

Notes:

• The MT supports PDP type IP only.

• AT&F and ATZ will undefine every context which is not active or not online.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 148

Chapter 11 – GPRS Commands

11.7 AT+CGEQMIN 3G Quality of Service Profile

(Minimum Acceptable)

Description: The test command returns values supported as a compound value.

The

The write command allows the TE to specify a Quality of Service Profile for the context identified by the (local) context identification parameter <cid> which is checked by the MT against the negotiated profile returned in the Activate/Modify PDP Context Accept message. A special form of the write command, AT+CGEQMIN=<cid> causes the requested profile for context number <cid> to become undefined.

AT&F and ATZ will undefine the QoS profiles of every context which is not active or not online.

Test Command Syntax: AT+CGEQMIN=?

Response(s): +CGEQMIN : <PDP_type>, (list of supported <Traffic class>s), (list of supported

<Maximum bitrate UL>s), (list of supported <Maximum bitrate DL>s), (list of supported

<Guaranteed bitrate UL>s), (list of supported <Guaranteed bitrate DL>s), (list of supported

<Delivery order>s), (list of supported <Maximum SDU size>s), (list of supported <SDU error ratio>s), (list of supported <Residual bit error ratio>s), (list of supported <Delivery of erroneous SDUs>s), (list of supported <Transfer delay>s), (list of supported <Traffic handling priority>s)

OK

Read Command Syntax: AT+CGEQMIN?

Response(s): [+CGEQMIN: <cid>, (list of supported <Traffic class>s), (list of supported <Maximum bitrate UL>s), (list of supported <Maximum bitrate DL>s), (list of supported <Guaranteed bitrate UL>s), (list of supported <Guaranteed bitrate DL>s), (list of supported <Delivery order>s), (list of supported <Maximum SDU size>s), (list of supported <SDU error ratio>s),

(list of supported <Residual bit error ratio>s), (list of supported <Delivery of erroneous

SDUs>s), (list of supported <Transfer delay>s), (list of supported <Traffic handling priority>s)] [+CGEQMIN: ...]

Write Command Syntax: AT+CGEQMIN=[<cid>[, <Traffic class>[, <Maximum bitrate UL>[, <Maximum bitrate DL>[,

<Guaranteed bitrate UL>[, <Guaranteed bitrate DL>[, <Delivery order>[, <Maximum SDU size>[, <SDU error ratio>[, <Residual bit error ratio>[, <Delivery of erroneous SDUs>[,

<Transfer delay>[, <Traffic handling priority>]]]]]]]]]]]]]

OK

ERROR

Parameter Descriptions:

<cid>

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands.

1...2

<Traffic class>

0 conversational

1

2

3

4 streaming interactive background subscribed value. Default

<Maximum bitrate UL>

This parameter indicates the maximum number of kbits/s delivered to UMTS (up-link traffic) at a SAP. As an example a bitrate of 32kbit/s would be specified as 32 (e.g., AT+CGEQMIN=...,32,...).

0 subscribed value. Default.

1...63

64...128

256

512

(value needs to be divisible by 8 without remainder)

<Maximum bitrate DL>

This parameter indicates the maximum number of kbits/s delivered by UMTS (down-link traffic) at a SAP. As an example a bitrate of 32kbit/s would be specified as 32 (e.g., AT+CGEQMIN=...,32,...).

0

1...63

64...256

512 subscribed value. Default.

(value needs to be divisible by 8 without remainder)

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 149

Chapter 11 – GPRS Commands

<Guaranteed bitrate UL>

This parameter indicates the guaranteed number of kbits/s delivered to UMTS (up-link traffic) at a SAP (provided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32

(e.g., AT+CGEQMIN=...,32,...).

0

1...63

64...128 subscribed value. Default.

(value needs to be divisible by 8 without remainder)

<Guaranteed bitrate DL>

This parameter indicates the guaranteed number of kbits/s delivered by UMTS (down-link traffic) at a SAP

(provided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32

(e.g., AT+CGEQMIN=...,32,...).

0

1...63

64...256 subscribed value Default.

(value needs to be divisible by 8 without remainder)

<Delivery order>

This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.

0

1

2 no yes subscribed value. Default.

<Maximum SDU size>

This parameter indicates the maximum allowed SDU size in octets.

0

10...1520

1502 subscribed value. Default.

(value needs to be divisible by 10 without remainder)

<SDU error ratio>

This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous. SDU error ratio is defined only for conforming traffic. The value is specified as “mEe”. As an example a target SDU error ratio of 5*10-3 would be specified as “5E3” (e.g., AT+CGEQMIN=...,”5E3”,...). subscribed value. Default “0E0“

“1E2“

“7E3“

“1E3“

“1E4“

“1E5“

“1E6“

“1E1“

<Residual bit error ratio>

This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested, Residual bit error ratio indicates the bit error ratio in the delivered SDUs. The value is specified as “mEe”. As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”

(e.g., AT+CGEQMIN=...,”5E3”,...).

“0E0“ subscribed value. Default

“5E2“

“1E2“

“5E3“

“4E3“

“1E3“

“1E4“

“1E5“

“1E6“

“6E8“

<Delivery of erroneous SDUs>

This parameter indicates whether SDUs detected as erroneous shall be delivered or not.

0

1

2

3 no yes no detect subscribed value. Default

<Transfer delay>

This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP, in milliseconds.

0

10...150

200...950

1000...4000 subscribed value. Default

(value needs to be divisible by 10 without remainder)

(value needs to be divisible by 50 without remainder)

(value needs to be divisible by 100 without remainder)

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 150

Chapter 11 – GPRS Commands

<Traffic handling priority>

This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS bearer compared to the SDUs of the other bearers.

0 subscribed. Default

1

2

3

<PDP_type>

Packet Data Protocol Type

“IP“

Notes:

• If parameters are not defined, the parameter default values depend on the HLR-stored subscribed default values.

• Definitions of parameters can be found in 3GPP TS 23.107

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 151

Chapter 11 – GPRS Commands

11.8 AT+CGEQREQ 3G Quality of Service Profile

(Requested)

Description: The test command returns values supported as a compound value.

The

The write command allows the TE to specify a Quality of Service Profile for the context identified by the (local) context identification parameter <cid> which is used when the MT sends an Activate

PDP Context Request message to the network.

A special form of the write command, AT+CGEQREQ=<cid> causes the requested profile for context number <cid> to become undefined.

AT&F and ATZ will undefine the QoS profiles of every context which is not active or not online.

Test Command Syntax: AT+CGEQREQ=?

Response(s): +CGEQREQ : <PDP_type>, (list of supported <Traffic class>s), (list of supported

<Maximum bitrate UL>s), (list of supported <Maximum bitrate DL>s), (list of supported

<Guaranteed bitrate UL>s), (list of supported <Guaranteed bitrate DL>s), (list of supported

<Delivery order>s), (list of supported <Maximum SDU size>s), (list of supported <SDU error ratio>s), (list of supported <Residual bit error ratio>s), (list of supported <Delivery of erroneous SDUs>s), (list of supported <Transfer delay>s), (list of supported <Traffic handling priority>s)

OK

Read Command Syntax: AT+CGEQREQ?

Response(s): [+CGEQREQ: <cid>, (list of supported <Traffic class>s), (list of supported <Maximum bitrate UL>s), (list of supported <Maximum bitrate DL>s), (list of supported <Guaranteed bitrate UL>s), (list of supported <Guaranteed bitrate DL>s), (list of supported <Delivery order>s), (list of supported <Maximum SDU size>s), (list of supported <SDU error ratio>s),

(list of supported <Residual bit error ratio>s), (list of supported <Delivery of erroneous

SDUs>s), (list of supported <Transfer delay>s), (list of supported <Traffic handling priority>s)]

Write Command Syntax: AT+CGEQREQ=[<cid>[, <Traffic class>[, <Maximum bitrate UL>[, <Maximum bitrate

DL>[, <Guaranteed bitrate UL>[, <Guaranteed bitrate DL>[, <Delivery order>[, <Maximum

SDU size>[, <SDU error ratio>[, <Residual bit error ratio>[, <Delivery of erroneous

Response(s):

SDUs>[, <Transfer delay>[, <Traffic handling priority>]]]]]]]]]]]]]

OK

ERROR

ERROR

Parameter Descriptions:

<cid>

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands.

1...2

<Traffic class>

0

1

2

3

4 conversational streaming interactive background subscribed value. Default

<Maximum bitrate UL>

This parameter indicates the maximum number of kbits/s delivered to UMTS (up-link traffic) at a SAP. As an example a bitrate of 32kbit/s would be specified as 32 (e.g. AT+CGEQREQ=...,32,...). subscribed value. Default. 0

1...63

64...128

256

512

(value needs to be divisible by 8 without remainder)

<Maximum bitrate DL>

This parameter indicates the maximum number of kbits/s delivered by UMTS (down-link traffic) at a SAP. As an example a bitrate of 32kbit/s would be specified as 32 (e.g. AT+CGEQREQ=...,32,...).

0 subscribed value. Default

1...63

64...256

512

(value needs to be divisible by 8 without remainder)

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 152

Chapter 11 – GPRS Commands

<Guaranteed bitrate UL>

This parameter indicates the guaranteed number of kbits/s delivered to UMTS (up-link traffic) at a SAP (provided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32

(e.g., AT+CGEQREQ=...,32,...).

0

1...63

64...128 subscribed value. Default

(value needs to be divisible by 8 without remainder)

<Guaranteed bitrate DL>

This parameter indicates the guaranteed number of kbits/s delivered by UMTS (down-link traffic) at a SAP

(provided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32

(e.g., AT+CGEQREQ=...,32,...).

0 subscribed value. Default

1...63

64...256 (value needs to be divisible by 8 without remainder)

<Delivery order>

This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.

0

1

2 no yes subscribed value. Default

<Maximum SDU size>

This parameter indicates the maximum allowed SDU size in octets.

0

10...1520

1502 subscribed value. Default

(value needs to be divisible by 10 without remainder)

<SDU error ratio>

This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous. SDU error ratio is defined only for conforming traffic. The value is specified as “mEe”. As an example a target SDU error ratio of 5*10-3 would be specified as “5E3” (e.g., AT+CGEQREQ =...,”5E3”,...). subscribed value. Default “0E0“

“1E2“

“7E3“

“1E3“

“1E4“

“1E5“

“1E6“

“1E1“

<Residual bit error ratio>

This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested, Residual bit error ratio indicates the bit error ratio in the delivered SDUs. The value is specified as “mEe”. As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”

(e.g., AT+CGEQREQ=...,”5E3”,...).

“0E0“ subscribed value. Default

“5E2“

“1E2“

“5E3“

“4E3“

“1E3“

“1E4“

“1E5“

“1E6“

“6E8“

<Delivery of erroneous SDUs>

This parameter indicates whether SDUs detected as erroneous shall be delivered or not.

0

1

2

3 no yes no detect subscribed value. Default

<Transfer delay>

This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP, in milliseconds.

[0]

10...150

200...950

1000...4000 subscribed value. Default

(value needs to be divisible by 10 without remainder)

(value needs to be divisible by 50 without remainder)

(value needs to be divisible by 100 without remainder)

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 153

Chapter 11 – GPRS Commands

<Traffic handling priority>

This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS bearer compared to the SDUs of the other bearers.

0 subscribed. Default

1

2

3

<PDP_type>

Packet Data Protocol Type

“IP“

Notes:

• If parameters are not defined, the parameter default values depend on the HLR-stored subscribed default values.

• Definitions of parameters can be found in 3GPP TS 23.107

11.9 AT+CGPADDR Show PDP Adress

Description: The test command returns a list of defined <cid>s.

The write command returns a list of PDP addresses for the specified context identifiers. If no

<cid> is specified, the addresses for all defined contexts are returned.

Test Command Syntax: AT+CGPADDR=?

Response: [+CGPADDR: (list of defined <cid>s)]

OK

Write Command Syntax: AT+CGPADDR=[<cid>[,<cid>]]

Response: [+CGPADDR: <cid>, <PDP_address>]

[+CGPADDR: <cid>, <PDP_address>]

OK

ERROR

ERROR

Parameter Descriptions:

<cid>

A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

<PDP_address>

A string that identifies the MT in the address space applicable to the PDP. The address may be static or dynamic.

Note:

If no <cid> is specified, the write command will return a list of all defined contexts.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 154

Chapter 11 – GPRS Commands

11.10 AT+CGQMIN Quality of Service Profile

(Minimum Acceptable)

Description: The test command returns values supported as a compound value. If the MT supports several

PDP types, the parameter value ranges for each PDP type are returned on a separate line.

The read command returns the current settings for each defined context.

This command allows the TE to specify a minimum acceptable profile which is checked by the

MT against the negotiated profile returned in the Activate PDP Context Accept message.

The set command specifies a profile for the context identified by the (local) context identification parameter, <cid>.

A special form of the set command, AT+CGQMIN= <cid> causes the minimum acceptable profile for context number <cid> to become undefined. In this case no check is made against the negotiated profile.

AT&F and ATZ will undefine the minimum QoS profiles of every context which is not active or not online.

Test Command Syntax: AT+CGQMIN=?

Response: +CGQMIN: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s),

(list of supported <reliability>s), (list of supported <peak>s), (list of supported <mean>s)

OK

ERROR

ERROR

Read Command Syntax: AT+CGQMIN?

Response: [+CGQMIN : <cid>, <precedence>, <delay>, <reliability>, <peak>, <mean>]

[+CGQMIN

OK

ERROR

+CME

AT+CGQMIN=[<cid>[, <precedence>[, <delay>[, <reliability>[, <peak>[, <mean>]]]]]] Write Command:

Response: OK

ERROR

+CME

Parameter Descriptions:

<cid>

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands.

1...2

<precedence>

Precedence class

0

1

2

3

Network subscribed value. Default.

High Priority. Service commitments shall be maintained ahead of precedence classes 2 and 3

Normal priority. Service commitments shall be maintained ahead of precedence class 3

Low priority. Service commitments shall be maintained

<delay>(num)

Delay class

The delay parameter defines the end-to-end transfer delay incurred in the transmission of SDUs through the

GPRS network(s).

0 Network subscribed value. Default.

1..4 SDU size: 128 octets and

SDU size: 1024 octets:

Delay Class Mean Transfer Delay 95 percentile

1 (Predictive) <0.5

2 (Predictive) <5

3 (Predictive) <50

<1.5

<25

<250

4 (Best Effort) Unspecified

<reliability>

Reliability class

0

1

2

3

4

5

Network subscribed value. Default.

Non real-time traffic, error-sensitive application that cannot cope with data loss

Non real-time traffic, error-sensitive application that can cope with infrequent data loss

Non real-time traffic, error-sensitive application that can cope with data loss, GMM/SM, and SMS

Real-time traffic, error-sensitive application that can cope with data loss

Real-time traffic, error non-sensitive application that can cope with data loss

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 155

Chapter 11 – GPRS Commands

9

10

11

12

13

14

15

16

5

6

7

8

1

2

3

4

<peak>

Peak throughput class (in octets per second).

0

5

6

7

8

1

2

3

4

9

<mean>

0 network subscribed value. Default

Up to 1 000 (8 kbit/s).

Up to 2 000 (16 kbit/s).

Up to 4 000 (32 kbit/s).

Up to 8 000 (64 kbit/s).

Up to 16 000 (128 kbit/s).

Up to 32 000 (256 kbit/s).

Up to 64 000 (512 kbit/s).

Up to 128 000 (1024 kbit/s).

Up to 256 000 (2048 kbit/s).

Mean throughput class(in octets per hour).

Network subscribed value. Default.

100 (~0.22 bit/s)

200 (~0.44 bit/s)

500 (~1.11 bit/s)

17

18

31

<PDP_type>

1 000 (~2.2 bit/s)

2 000 (~4.4 bit/s)

5 000 (~11.1 bit/s)

10 000 (~22 bit/s)

20 000 (~44 bit/s)

50 000 (~111 bit/s)

100 000 (~0.22 kbit/s)

200 000(~0.44 kbit/s)

500 000(~1.11 kbit/s)

1 000 000 (~2.2 kbit/s)

2 000 000 (~4.4 kbit/s)

5 000 000 (~11.1 kbit/s)

10 000 000 (~22 kbit/s)

20 000 000 (~44 kbit/s)

50 000 000 (~111 kbit/s) best effort

Packet Data Protocol Type

“IP“

Notes:

• If parameters are not defined, the parameter default values depend on the HLR-stored subscribed default values.

• Definitions of parameters in GSM 02.60 and GSM 03.60 paragraph 15.2 “Quality of Service Profile”.

Example:

If some of the QoS parameters are omitted, they will keep their current value (or the default value if not specified).

For example:

AT+CGDCONT=1,”IP”

OK

AT+CGQMIN=

OK

AT+CGQMIN?

OK

AT+CGQMIN=1,0

OK

AT+CGQMIN?

+CGQMIN:1,0,0,0,0,0

OK

AT+CGQMIN=1,0,0,0,1

OK

AT+CGQMIN?

+CGQMIN:1,0,0,0,1,0

OK

AT+CGQMIN=1,1

OK

AT+CGQMIN?

+CGQMIN:1,1,0,0,1,0

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 156

Chapter 11 – GPRS Commands

11.11 AT+CGQREQ Quality of Service Profile

(Requested)

Description: The test command returns values supported as a compound value. If the MT supports several

PDP types, the parameter value ranges for each PDP type are returned on a separate line.

The read command returns the current settings for each defined context. If no requested profile was explicitly specified for a context, simply OK will be returned, but default values will be used for that context.

This command allows the TE to specify a Quality of Service Profile that is used when the MT sends an Activate PDP Context Request message to the network.

The set command specifies a profile for the context identified by the (local) context identification parameter, <cid>.

A special form of the set command, +CGQREQ=<cid> causes the requested profile for context number <cid> to become undefined.

AT&F and ATZ will undefine the QoS profiles of every context which is not active or not online.

Test Command Syntax: AT+CGQREQ=?

Response: +CGQREQ: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s),

(list of supported <reliability>s), (list of supported <peak>s), (list of supported <mean>s)

OK

Read Command Syntax: AT+CGQREQ?

Response:

Write Command:

Response:

[+CGQREQ: <cid>, <precedence>, <delay>, <reliability>, <peak>, <mean>]

[+CGQREQ: ...]

AT+CGQREQ=[<cid>[, <precedence>[, <delay>[, <reliability>[, <peak>[, <mean>]]]]]]

OK

ERROR

+CME ERROR

Parameter Descriptions:

<cid>

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands.

1...2

<precedence>

Precedence class

0

1

2

3

<delay>

Delay class

Network subscribed value. Default.

High Priority. Service commitments shall be maintained ahead of precedence classes 2 and 3.

Normal priority. Service commitments shall be maintained ahead of precedence class 3.

Low priority. Service commitments shall be maintained.

This parameter defines the end-to-end transfer delay incurred in the transmission of SDUs through the GPRS network(s).

0

1..4

Network subscribed value. Default. with SDU size = 128 octets and with SDU size = 1024 octets:

Delay Class Mean Transfer Delay 95 percentile

1 (Predictive) <0.5

2 (Predictive) <5

3 (Predictive) <50

<1.5

<25

<250

4 (Best Effort) Unspecified

<reliability>

Reliability class

0

1

2

3

4

5

Network subscribed value. Default.

Non real-time traffic, error-sensitive application that cannot cope with data loss

Non real-time traffic, error-sensitive application that can cope with infrequent data loss

Non real-time traffic, error-sensitive application that can cope with data loss, GMM/SM, and SMS

Real-time traffic, error-sensitive application that can cope with data loss

Real-time traffic, error non-sensitive application that can cope with data loss

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 157

Chapter 11 – GPRS Commands

<peak>

Peak throughput class in octets per second

0

1

2

3

4 network subscribed value. Default.

Up to 1 000 (8 kbit/s)

Up to 2 000 (16 kbit/s)

Up to 4 000 (32 kbit/s)

Up to 8 000 (64 kbit/s)

5

6

7

8

Up to 16 000 (128 kbit/s)

Up to 32 000 (256 kbit/s)

Up to 64 000 (512 kbit/s)

Up to 128 000 (1024 kbit/s)

Up to 256 000 (2048 kbit/s) 9

<mean>

Mean throughput class in octets per hour

0

1

2

3

4

Network subscribed value. Default.

100 (~0.22 bit/s)

200 (~0.44 bit/s)

500 (~1.11 bit/s)

1 000 (~2.2 bit/s)

5

6

7

8

9

10

11

12

13

14

15

16

2 000 (~4.4 bit/s)

5 000 (~11.1 bit/s)

10 000 (~22 bit/s)

20 000 (~44 bit/s)

50 000 (~111 bit/s)

100 000 (~0.22 kbit/s)

200 000(~0.44 kbit/s)

500 000(~1.11 kbit/s)

1 000 000 (~2.2 kbit/s)

2 000 000 (~4.4 kbit/s)

5 000 000 (~11.1 kbit/s)

10 000 000 (~22 kbit/s)

17

18

20 000 000 (~44 kbit/s)

50 000 000 (~111 kbit/s)

31

<PDP_type>(str) best effort

Packet Data Protocol type

“IP“

Notes:

• If parameters are not defined, the parameter default values depend on the HLR-stored subscribed default values.

• Definitions of parameters in GSM 02.60 and GSM 03.60 paragraph 15.2 “Quality of Service Profile”.

Example:

If some of the QoS parameters are omitted, they will keep their current value (or the default value if not specified so far). For example:

AT+CGDCONT=1,”IP”

OK

AT+CGQREQ=

OK

AT+CGQREQ?

+CGQREQ:1,0,0,0,0,0

OK

AT+CGQREQ=1,0,

OK

AT+CGQMIN?

+CGQREQ:1,0,0,0,0,0

OK

AT+CGQREQ=1,0,0,0,1

OK

AT+CGQREQ?

+CGQREQ:1,0,0,0,1,0

OK

+CGQREQ:1,1

OK

+CGQREQ:1,1,0,0,1,0

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 158

Chapter 11 – GPRS Commands

11.12 AT+CGREG GPRS Network Registration

Status

Description: The read command returns the status of result code presentation and an integer <stat> which shows whether the network has currently indicated the registration of the MT. Location information elements <lac> and <ci> are returned only when <n>=2 and MT is registered in the network.

The read command returns the status of result code presentation and an integer <stat> which shows whether the network has currently indicated the registration of the MT.

The write command controls the presentation of an unsolicited result code “+CGREG: <stat>” when <n>=1 and there is a change in the MT’s GPRS network registration status, or unsolicited result code “+CGREG: <stat>, <lac>, <ci>,” when <n>=2 and there is a change of the network cell.

Test Command Syntax: AT+CGREG=?

Response: +CGREG: (list of supported <n>s)

OK

Read Command Syntax: AT+CGREG?

Response: +CGREG: <n>, <stat>

OK

Write Command Syntax: AT+CGREG=[<n>]

Response: OK

ERROR

+CME ERROR

Parameter Descriptions:

<n>

0

1

2

Disable network registration unsolicited result code

Enable network registration unsolicited result code “+CGREG: <stat>”

Enable network registration unsolicited result code “+CGREG: <stat>, <lac>, <ci>”

<stat>

0

1

2

3

4

5

Not registered; ME is not currently searching an operator to register to. The ME is in GMM state

GMM-NULL or GMM-DEREGISTERED-INITIATED.

The GPRS service is disabled; the ME is allowed to attach to GPRS if requested by the user.

Registered; home network. The ME is in GMM state GMM-REGISTERED or GMM-ROUTING-

AREA-UPDATING-INITIATED INITIATED on the home PLMN

Not registered, but ME is currently trying to attach or searching an operator to register to. The

ME is in GMM state GMM-DEREGISTERED or GMM-REGISTERED-INITIATED. The GPRS service is enabled, but an allowable PLMN is currently not available. The ME will start a GPRS attach as soon as an allowable PLMN is available.

Registration denied. The ME is in GMM state GMM-NULL. The GPRS service is disabled, the

ME is not allowed to attach to GPRS if requested by the user.

Unknown

Registered; roaming. The ME is in GMM state GMM-REGISTERED or GMMROUTING-AREA-

UPDATING-INITIATED on a visited PLMN.

<lac>

Two-byte location area code in hexadecimal format.

<ci>

Two-byte cell ID in hexadecimal format.

Unsolicited Result Code:

URC 1

+CGREG: <stat>

Indicates a change in the MT’s GPRS network registration status.

URC 2

+CGREG: <stat>, <lac>, <ci>

Indicates a change in the MT’s GPRS network registration status and a change in of the network cell including location information.

Note:

When the module is GPRS attached and a PLMN reselection occurs to a non-GPRS network or to a network where the SIM is not subscribed to for using GPRS, the resulting GMM (GPRS mobility management) state according to

GSM 24.008 is REGISTERED/NO CELL, meaning that the read command will still show <stat>=1 or <stat>=5.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 159

Chapter 11 – GPRS Commands

11.13 AT+CGSMS Select Service for MO SMS

Messages

Description: The test command is used for requesting information on which services and service preferences can be set by using the AT+CGSMS write command.

The read command returns the currently selected service or service preference.

The write command is used to specify the service or service preference that the MT will use to send MO SMS messages. If parameter <service> is not given, the current value remains unchanged.

Test Command Syntax: AT+CGSMS=?

Response: +CGSMS: (list of supported <service>s)

OK

Read Command Syntax: AT+CGSMS?

Response: +CGSMS: <service>

OK

Write Command Syntax: AT+CGSMS=[<service>]

Response: OK

ERROR

Parameter Descriptions:

<service>

A numeric parameter which indicates the service or service preference to be used. The parameter is global for all interfaces and is volatile.

0

1

2

GPRS

Circuit switched

GPRS prefered (use circuit-switched SMS transfer if GPRS SMS transfer is not possible; for example, when the mobile is not GPRS attached or the network does not support SMS over GPRS).

Circuit switched preferred (use GPRS if circuit switched is not available). Default. 3

Notes:

• Sending SMS via GPRS is only possible when mobile is attached using AT+CGATT.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 160

Chapter 11 – GPRS Commands

11.14 AT^SGACT Query All PDP Context Activations

Description: The test command returns supported interfaces and states.

The

Contexts, which are created internally by the GPRS modem compatibility commands, will displayed only, if they are activated. The Output of this command is unsorted.

The

Test Command Syntax: AT^SGACT=?

Response(s): ^SGACT: (range of supported <ifc>s) , (range of supported <state>s)

OK

Read Command Syntax: AT^SGACT?

Response(s): [^SGACT: <ifc>, <cid>, <state>]

[^SGACT: <ifc>, <cid>, <state>]

...]

OK

Exec Command Syntax: AT^SGACT

Response(s): ^SGACT: <sum>

OK

Parameter Descriptions:

<ifc>

Interface

Indicates the interface on which a particular PDP context was defined. Every PDP context defined with the command AT+CGDCONT or internally by the GPRS modem compatibility commands is identified one-to-one by its (local) context identifier and the interface on which it was defined. The range of supported interfaces is returned by the test command.

0

1

2

ASC0 or Multiplex channel 1

ASC1 or Multiplex channel 2

USB or Multiplex channel 3

<cid>

PDP context identifier

The interface local identifier which was used to define a PDP context using the command AT+CGDCONT or which was created internally by using the GPRS modem compatibility commands ATD*98# or ATD*99#. The range of supported values is returned by the AT+CGDCONT test command. Values 3 and 4 will be used by the

GPRS modem compatibility commands ATD*98# or ATD*99# if no context identifier was specified as the command was invoked.

<state>

PDP context activation state

Indicates the state of the PDP context activation.

0

1

Deactivated

Activated

<sum>

The sum of all activated PDP contexts of the ME.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 161

Chapter 11 – GPRS Commands

11.15 AT^SGAUTH Set Type of Authentication for

PPP Connection

Test Command Syntax: AT^SGAUTH=?

Response: ^SGAUTH: (list of supported <auth>s)

OK

ERROR

+CME ERROR

Read Command Syntax: AT^SGAUTH?

Response: ^SGAUTH: <auth>

OK

ERROR

+CME ERROR

Write Command Syntax: AT^SGAUTH=<auth>

Response: OK

ERROR

+CME ERROR

Parameter Descriptions:

<auth> Indicates types of supported authentication.

0

1

2 none

PAP

CHAP

3 PAP and CHAP. Default

11.16 AT^SGCONF Configuration of GPRS-Related

Parameters

Test Command Syntax: AT^SGCONF=? Several changes in text in this command

Response: ^SGCONF : (list of supported <llc_pdu_length>_U>s), (list of supported

OK

Read Command Syntax: AT^SGCONF?

Response:

<llc_pdu_length>_I>s), (list of supported <GPRS msclass>es), (list of supported <EGPRS msclass>es)

^SGCONF: <llc_pdu_length_U>, <llc_pdu_length>_I>, <GPRS msclass>, <EGPRS msclass>

OK

Write Command Syntax: AT^SGCONF=[<llc_pdu_length_U>][, [<llc_pdu_length>_I>][, [<GPRS

Response: msclass>][<EGPRS msclass>]]]]

OK

ERROR

+CME

Parameter Descriptions:

<llc_pdu_length_U>

The maximum number of octets in an information field of Unnumbered (U) frames.

0 No negotiation with network (500 will be used)

140...1520 Lower values diminish performance. 1520 is the powerup default.

<llc_pdu_length _I >

The maximum number of octets in an information field of Combined (I) frames.

0 No negotiation with network (500 will be used)

140...1520 Lower values diminish performance. 1520 is the powerup default.

<GPRS msclass>

GPRS Multislot Class. The parameter can be changed only when the MT is detached; otherwise, “CME ERROR: operation temporary not allowed” will be returned. The value can be one of the classes indicated with the Test command. The value set is volatile and powerup value is the maximum allowed.

<EGPRS msclass>

EGPRS Multislot Class. The parameter can be changed only when the MT is detached; otherwise, “CME

ERROR: operation temporary not allowed” will be returned. The value can be one of the classes indicated with the Test command. The value set is volatile and powerup value is the maximum allowed.

Notes:

• +CME ERROR: invalid index: Parameter is out of range

• +CME ERROR: operation temporary not allowed: The command is blocked as long as GPRS is already in use

(as long as mobile is GPRS attached).

• Writing to user profile with AT&W and restoring with AT&F are not supported.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 162

Chapter 11 – GPRS Commands

11.17 ATA Manual Response to a Network Request for PDP Context Activation

Description: The V.250 ATA command may be used to accept a network request for a PDP context activation announced by the unsolicited result codes “RING” or “+CRING: GPRS”. The MT responds with CONNECT, enters V.250 online data state and follows the same procedure as it would after having received a AT+CGANS=1 with no <L2P> or <cid> values specified.

If you try to answer a request which is no longer present or which is already answered by another instance, NO CARRIER is returned.

Exec Command Syntax: ATA

Response: CONNECT

CARRIER

11.18 ATD*99# Request GPRS Service

Description: This command causes the MT to perform whatever actions are necessary to establish communication between the TE and the external PDN.

The V.250 ‘D’ (Dial) command causes the MT to enter the V.250 online data state and, with the

TE, to start the specified layer 2 protocol. No further commands may follow on the AT command line. GPRS attachment and PDP context activation procedures may take place prior to or during the PDP startup if they have not already been performed using the AT+CGATT and AT+CGACT commands.

See command examples in Section 11.22, “Using GPRS AT commands (Examples)”.

To confirm acceptance of the command before entering the V.250 online data state command will respond with CONNECT.

When the layer 2 protocol has terminated, either as a result of an orderly shut down of the PDP or an error, the MT enters V.250 command state and returns NO CARRIER (for details refer to

Section 11.5.1, Automatic deactivation of PDP context during dial-up PPP).

Exec Command Syntax: ATD*99[* [<called_address>][* [<L2P>][* [<cid>]]]]#

Response: CONNECT

NO

Parameter Descriptions:

<called_address>

This parameter is currently not used and needs not to be specified.

<L2P>

Layer 2 protocol to be used between the TE and MT.

“PPP“

“1“

Layer 2 protocol PPP

Layer 2 protocol PPP

<cid>

Parameter specifies a particular PDP context definition (see AT+CGDCONT). If no context is specified, an internal context with default properties is used (see AT+CGDCONT, AT+CGQREQ and AT+CGQMIN).

1...2

Notes:

• If the Multi-Tech wireless modem is in dedicated mode, command returns the result code BUSY.

• ATD is used as a standard V.250 AT command, too.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 163

Chapter 11 – GPRS Commands

11.19 ATD*98# Request GPRS IP Service

Description: This command causes the MT to perform whatever actions are necessary to establish communication between the TE and the external PDN.

The V.250 ‘D’ (Dial) command causes the MT to enter the V.250 online data state and, with the

TE, to start the layer 2 protocol.

GPRS attachment and PDP context activation procedures may take place prior to or during the

PDP startup if they have not already been performed using AT+CGATT and AT+CGACT.

To confirm acceptance of the command before entering the V.250 online data state, command will respond with CONNECT.

When the layer 2 protocol has terminated, either as a result of an orderly shut down of the PDP or an error, the MT enters V.250 command state and returns NO CARRIER (for details refer to

Section 11.5.1, Automatic deactivation of PDP context during dial-up PPP).

Exec Command Syntax: ATD*98[* <cid>]#

Response: CONNECT

NO

Parameter Descriptions:

<cid>

Parameter specifies a particular PDP context definition (see AT+CGDCONT command). If no context is specified, an internal context with default properties is used (see AT+CGDCONT, AT+CGQREQ and

AT+CGQMIN).

1...2

Notes:

• If the Multi-Tech wireless modem is in dedicated mode, command returns the result code BUSY.

• ATD is used as a standard V.250 AT command, too.

11.20 ATH Manual Rejection of a Network Request for PDP Context Activation

Description: The V.250 ATH command may be used to deactivate all PDP contexts which are active or online on the same interface. This command should not be used to deactivate PDP contexts during the implicit PDP context deactivation procedure which is started automatically after LCP termination or by dropping the DTR line (if AT&D2 is configured). For details refer to Section 11.5.1,

“Automatic deactivation of PDP context during dial-up PPP”.

The ATH command may also be used to reject a network request for PDP context activation announced by the unsolicited result codes “RING: GPRS” or “+CRING: GPRS”.

Exec Command Syntax: ATH

Response: OK

Notes:

• In contrast to GSM 07.07 it is possible to cancel a connection with ATH after a break. This is done for compatibility reasons due to the “dial-up network” drivers of Microsoft Windows.

• ATH is used as a standard V.250 AT command, too.

• If ATH is used to reject a network request for PDP context activation, then other PDP contexts on the same interface which are active or online will not be deactivated.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 164

Chapter 11 – GPRS Commands

11.21 ATS0 Automatic Response to a Network

Request for PDP Context Activation

Description: The V.250 ATS0=<n> (Automatic answer) command may be used to turn off (n=0) and on (n>0) the automatic response to a network request for a PDP context activation.

When the ATS0=<n> (<n> > 0) command is received, the MT will attempt to perform a GPRS attach if not yet attached and if configured to do so (see AT^SCFG, parameter <gs0aa>). Failure will result in ERROR being returned to the TE. Subsequently, the MT will announce a network request for PDP context activation by issuing the URC RING or CRING to the TE, followed by the intermediate result code CONNECT. The MT then enters V.250 online data state and follows the same procedure as it would after having received a AT+CGANS=1 command with no <L2P> or

<cid> values specified.

ATS0=0 does not perform an automatic GPRS detach.

Read Command Syntax: ATS0?

Response: <n>

OK

Write Command Synatx: ATS0=<n>

Response: OK

Parameter Description:

<n>

000 Disables automatic answer mode. Default.

001-255 Enables automatic answering after specified number of rings.

Notes:

• If different settings are used on each interface, and a request for PDP context activation is received, the interface

‘wins’ which is idle and uses the smallest ATS0 value.

• If a network request for PDP context activation is answered automatically and another AT command is issued at the same time on the same interface then this AT command will not be executed. Any response belongs to the automatic context activation procedure. If the AT command which caused the collision was a CS data call, the

CONNECT response does not belong to this data call but to the GPRS. This can be detected if ATX is not set to

0. CS data call will issue CONNECT <text>, GPRS will issue CONNECT only.

• A network request for PDP context activation has a maximum duration of approximately 40 seconds (for details see GSM 04.08). A RING/CRING URC is issued every 5 seconds, so setting parameter <n> to values greater than 7 will not allow a successful context activation and is not recommended.

• The automatic GPRS attach will not be performed on recalling a stored user profile with ATZ or on powerup, if a n > 0 setting was stored in the user profile with AT&W.

• If the automatic GPRS attach fails (e.g., the network rejects the attach request), the write command returns error, though the new value takes effect. This is necessary because ATS0 is used for circuit switched calls too.

• ATS0 write command is PIN protected.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 165

Chapter 11 – GPRS Commands

11.22 Using GPRS AT Commands (Examples)

Example 1 – Defining and Using a Context Definition ID (CID):

Every time a CID is used as a parameter for a GPRS command the CID has to be defined before by using the

AT+CGDCONT command. To get the parameter of a CID use the AT+CGDCONT read option. If the response of

‘AT+CGDCONT?’ is OK only, there is no CID defined.

AT+CGDCONT?

OK There is no CID defined

All parameters of the CID are initiated by NULL or not present values, and the CID itself is set to be undefined.

To define a CID use the AT+CGDCONT command with at least one CID parameter. At the moment the mobile supports CID 1 and CID 2 by using the AT+CGDCONT command.

Define CID 1 and set the PDP type to IP, access point name and IP address are not set:

AT+CGDCONT=1,”IP”

OK

Define CID 2 and sets PDP type, APN and IP addr:

A following read command will respond:

AT+CGDCONT=2,”IP”, “internet.t-d1.gprs”, 111.222.123.234

OK

AT+CGDCONT?

+CGDCONT:1,”IP”,””,””,0,0

+CGDCONT:2,”IP”,”internet.t-d1.gprs”,111.222.123.234

OK

Set the CID 1 to be undefined:

A following read command will respond:

AT+CGDCONT=1

OK

AT+CGDCONT?

+CGDCONT:2,”IP”,”internet.t-d1.gprs”,111.222.123.234

OK

Example 2 – Quality of Service (QoS) is a special CID parameter that consists of several parameters itself:

• the precedence class

• the delay class

• the reliability class

• the peak throughput class

• the mean throughput class

It is also divided in “requested QoS” and “minimum acceptable QoS”.

All parameters of the QoS are initiated by default to the “network subscribed value (= 0)” but the QoS itself is set to be undefined. To define a QoS use the AT+CGQREQ or AT+CGQMIN command.

Overwrite the precedence class of QoS of CID 1 and set the QoS of CID 1 to be present:

A following read command will respond:

AT+CGQREQ=1,2

OK

AT+CGQREQ?

+CGQREQ: 1,2,0,0,0,0

OK

All QoS values of CID 1 are set to network subscribed now, except precedence class which is set to 2. Now set the QoS of CID 1 to not present:

AT+CGQREQ=1

OK

Once defined, the CID it can be activated. To activate CID 2 use:

AT+CGACT=1,2

OK

If the CID is already active, the mobile responds OK at once.

If no CID and no STATE is given, all defined CIDs will be activated by:

AT+CGACT=

OK

If no CID is defined the mobile responds +CME ERROR: invalid index.

Remark: If the mobile is NOT attached by AT+CGATT=1 before activating, the attach is automatically done by the AT+CGACT command.

After defining and activating a CID it may be used to get online by:

AT+CGDATA=”PPP”,1

CONNECT The mobile is connected using the parameters of CID 1.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 166

Chapter 11 – GPRS Commands

AT+CGDATA=

CONNECT The mobile is connected using default parameters

(<L2P>=”PPP” and <cid> as described for command

AT+CGDATA).

The mobile supports Layer 2 Protocol (L2P) PPP only.

Remark: If the mobile is NOT attached by AT+CGATT=1 and the CID is NOT activated before connecting, attaching and activating is automatically done by the AT+CGDATA command.

Some providers (e.g., Vodafone or E-Plus) require to use an APN to establish a GPRS connection. So if you use the Microsoft Windows Dial-Up Network and ATD*9... to connect to GPRS you must provide the context definition as part of the modem definition (Modem properties/Connection/Advanced.../Extra settings). As an alternative, you can define and activate the context in a terminal program (e.g., Microsoft Hyperterminal) and then use the Dial-Up Network to send only the ATD command.

11.23 Using the GPRS Dial Command ATD (Example)

In addition to the GPRS AT commands you can use the “D” command to dial into to the GPRS network.

There are two GPRS Service Codes for the ATD command: Values 98 and 99.

Examples:

ATD*99#

CONNECT ‘

ATD*99*123.124.125.126*PPP*1#

CONNECT

Establish a connection by service code 99.

Establish a connection by service code 99, IP address 123 and L2P = PPP and using CID 1.

The CID has to be defined by AT+CGDCONT.

ATD*99**PPP#

CONNECT

ATD*99***1#

CONNECT

ATD*99**PPP*1#

CONNECT

Establish a connection by service code 99 and L2P = PPP.

Establish a connection by service code 99 and using CID 1.

Establish a connection by service code 99 and L2P = PPP and using CID 1. The

CID has to be defined by AT+CGDCONT.

ATD*98#

CONNECT

ATD*98*1#

CONNECT

Establish a connection by service code 98.

Establish an IP connection by service code 98 using CID 1. The CID has to be defined by AT+CGDCONT.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 167

Chapter 12 – FAX Commands

Chapter 12. FAX Commands

The following commands can be used for FAX transmission. If the ME is acting as a Fax modem for a PC-based application (e.g., “WinFax”), it is necessary to select the proper Service Class (Fax Class) provided by the ME.

The ME reports its Service Class capabilities, both the current setting and the range of services available. This is provided by the AT+FCLASS command.

Service Classes supported by the ME:

AT+FCLASS Parameter Service Class

0 Data Modem

Reference, Standard

TIA/EIA-602 or ITU V.250

12.1 FAX Parameters

Parameter Description

<mod>

Modulation Mode

24

48

72

96

V.27ter - 2400 bps

V.27ter - 7200 bps

V.29 - 7200 bps

V.29 - 9600 bps

Note: Only the default value needs to be implemented. Use the test commands to check which parameter values are really possible.

12.2 AT+FCLASS Fax: Select, Read or Test Service

Class

Description: AT+FCLASS sets the ME to a particular mode of operation (data, fax). This allows the ME to process information in a manner suitable for that type of information.

Test Command Syntax: AT+FCLASS=?

Response: (list of supported <n>s)

OK

Read Command Syntax: AT+FCLASS?

Response: <n>

OK

Write Command Syntax: AT+FCLASS=<n>

Response: OK

Parameter Descriptions:

<n>

0

1

Data. Default.

Fax class 1 (Service Class 1)

Notes:

• Using Error Correcting Mode (ECM) when sending FAXes over GSM should be avoided.

• If <n> is set to 1, all incoming calls will be answered when ATA is issued on multiplexer channel 1 resp. ASC0.

For calls explicitly signaled as voice or data calls, this procedure will fail with result code “NO CARRIER”, but the incoming call will continue to ring.

It is possible to change the setting of <n> to 0 while the call is ringing, and accept the call normally afterwards with ATA.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 168

Chapter 12 – FAX Commands

12.3 AT+FRH Receive Data Using HDLC Framing

Description: The AT+FRH command enables the TA to receive frames using the HDLC protocol and the modulation defined in Section 12.1, FAX parameters. An ERROR response code results if this command is issued while the modem is on-hook.

Write Command Syntax: AT+FRH=<mod>

Response:

ERROR

Note:

CONNECT

If error related to ME functionality

Used for Fax Class 1 only.

12.4 AT+FRM Receive Data

Description: The AT+FRM command causes the TA to enter the receive mode using the modulation defined in Section 12.1, FAX parameters. An ERROR response code results if this command is issued while the modem is on-hook.

Test Command Syntax: AT+FRM=?

Response: (list of <mod>s)

OK

Write Command Syntax: AT+FRM=<mod>

Response: CONNECT

If error is related to ME functionality:

ERROR

Notes:

• Used for Fax Class 1 only.

• <mod>= 3 is not possible.

12.5 AT+FRS Receive Silence

Description: <time>=n causes the TA to report an OK result code to the TE after <time> 10 millisecond intervals of silence have been detected on the line. The command is aborted if any character is received by the DTE. The modem discards the aborting character and issues an OK result code. An ERROR response code results if this command is issued while the mode is on-hook.

Write Command Syntax: AT+FRS=<time>

Response: OK

If error related to ME functionality

ERROR

Parameter Description:

<time>

Number of 10 millisecond intervals

0...255

Note: Used for Fax Class 1 only.

12.6 AT+FTH Transmit Data Using HDLC Framing

Description: The AT+FTH command causes the TA to transmit data using HDLC protocol and the modulation mode defined in Section 12.1, FAX parameters. An ERROR response code results if this command is issued while the modem is on-hook

Write Command Syntax: AT+FTH=<mod>

Response: CONNECT

Notes:

• Used for Fax Class 1 only.

• Only <mod>= 3 is possible.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 169

Chapter 12 – FAX Commands

12.7

AT+FTM Transmit Data

Description: The AT+FTM command causes the TA to transmit data using the modulation mode defined in Section 12.1, FAX parameters. An ERROR response code results if this command is issued while the modem is on-hook.

Test Command Syntax: AT+FTM=?

Response: (list of <mod>s)

OK

Write Command Syntax: AT+FTM=<mod>

Response: CONNECT

If error is related to ME functionality

ERROR

Notes:

• Used for Fax Class 1 only.

• <mod>= 3 is not possible.

12.8

AT+FTS Stop Transmission and Wait

Description: This command causes the TA to terminate a transmission and wait for <time> 10 millisecond intervals before responding with the OK result code to the DTE.

Write Command Syntax: AT+FTS=<time>

Response: An ERROR response code results if this command is issued while the modem is onhook.

Parameter Description:

<time> no. of 10 millisecond intervals

0...85

Note: Used for Fax Class 1 only.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 170

Chapter 13 – Short Message Service (SMS) Commands

Chapter 13. Short Message Service

(SMS) Commands

The AT Commands described in this chapter allow an external application to use the Short Message Service with the

Multi-Tech wireless modem.

13.1 SMS Parameters

Parameter Descriptions:

<ackpdu>

Format is same for <pdu> in case of SMS, but without GSM 24.11 SC address field and parameter shall be bounded by double quote characters like a normal string type parameter.

<alpha>

String type alphanumeric representation of <da> or <oa> corresponding to the entry found in phonebook; implementation of this feature is manufacturer specific.

<cdata>

Command Data

GSM 03.40 TP-Command-Data in text mode responses; ME/TA converts each 8-bit octet into two IRA character long hexadecimal numbers (e.g., octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65))

<ct>

Command Type GSM 03.40 TP-Command-Type in integer format.

0...255. Default = 0.

<da>

Destination Address

Type of address given by <toda>.

GSM 03.40 TP- Destination-Address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted into characters;

<data>

User Data

In case of SMS: GSM 03.40 TP-User-Data in text mode responses; format:

• If <dcs> indicates that GSM 03.38 default alphabet is used and <fo> indicates that GSM 03.40 TP-User-

Data-Header-Indication is not set: ME/TA converts GSM alphabet into current TE character set according to rules covered in Annex A.

• If <dcs> indicates that 8-bit or UCS2 data coding scheme is used or <fo> indicates that GSM 03.40

TPUser-Data-Header-Indication is set, then the ME/TA converts each 8-bit octet into hexadecimal numbers containing two IRA characters (e.g., octet with integer value 42 is presented to TE as two characters 2A: IRA 50 and 65).

In case of CBS: GSM 03.41 CBM Content of Message in text mode responses; format:

• If <dcs> indicates that GSM 03.38 default alphabet is used: ME/TA converts GSM alphabet into current

TE character set according to rules covered in Annex A.

• If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each 8-bit octet into hexadecimal numbers containing two IRA characters.

<dt>

Discharge Time

GSM 03.40 TP-Discharge-Time in time-string format: “yy/MM/dd,hh:mm:ss+zz”, where characters indicate year

(two last digits), month, day, hour, minutes, seconds and time zone. For example, 6

GMT+2 hours equals “94/05/06,22:10:00+08” th

of May 1994, 22:10:00

<ieia>

IEIa (Information Element Identifier octet) of the concatenated SMS.

8

16

Concatenated short messages, 8-bit reference number.

Concatenated short messages, 16-bit reference number.

<index>

Integer type; value in the range of location numbers supported by the associated memory .

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 171

Chapter 13 – Short Message Service (SMS) Commands

<length>

Message Length

Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body <data> (or

<cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in octets (i.e., the

RP layer SMSC address octets are not counted in the length) In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if the 7 bit GSM coding scheme is used, and 140 characters according to the 8 bit GSM coding scheme.

If the SMS message format is “text mode” (AT+CMGF=1) and the character set is set to “UCS2” with AT+CSCS and the SMS is also coded as “UCS2” (see <dcs> of AT+CSMP), then the length is in octets instead of characters.

For concatenated SMS messages the maximum length will be reduced by the length of the user data header with respect to <ieia> (6 bytes for <ieia>=8 and 7 bytes for <ieia>=16). In the case of 8-bit data, the maximum length of the short message field is: 140 octets - (6 or 7) = 134 or 133. In the case of GSM 7 bit default alphabet data, the maximum length of the short message is (140 - (6 or 7))*8/7 = 153 or 152 characters. In the case of 16 bit

UC2 data, the maximum length of the short message is: (140 - (6 or 7))/2)= 67 or 66 characters.

<max>

Maximum number of all segments to be concatenated into one SMS, beginning with 1.

<max>=0 means: ignore the value. This will result in a non-concatenated SMS.

0...255

<mem1>

Memory to be used when listing, reading and deleting messages:

“SM“

“ME“

“MT“

SIM message storage

Mobile Equipment message storage

Sum of “SM” and “ME” storages. Default.

<mem2>

Memory to be used when writing and sending messages:

“SM“ SIM message storage

“ME“

“MT“

Mobile Equipment message storage

Sum of “SM” and “ME” storages. Default.

<mem3>

Received messages will be placed in this memory storage if routing to TE is not set. See command AT+CNMI with parameter <mt>=2.

“SM“

“MT“

SIM message storage

Sum of “SM” and “ME” storages. Default.

<mid>

Message Identifier

GSM 03.41 CBM Message Identifier in integer format.

<mn>

Message Number

GSM 03.40 TP-Message-Number in integer format.

<mr>

Message Reference

GSM 03.40 TP-Message-Reference in integer format.

<oa>

Originating Address

GSM 03.40 TP-Originating-Address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted into characters; type of address given by <tooa>.

<page>

Page Parameter

GSM 03.41 CBM Page Parameter bits 4-7 in integer format.

<pages>

Page Parameter

GSM 03.41 CBM Page Parameter bits 0-3 in integer format.

<pdu>

In the case of SMS: GSM 04.11 SC address followed by GSM 03.40 TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into hexadecimal numbers containing two IRA characters (e.g., octet with integer value 42 is presented to TE as two characters 2A: IRA 50 and 65). In the case of CBS: <ra> GSM 03.40

TPRecipient-Address Ad-dress-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted into characters; type of address given by <tora>.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 172

Chapter 13 – Short Message Service (SMS) Commands

<ra>

Recipient Address

GSM 03.40 TP-Recipient-Address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (refer to command

AT+CSCS.); type of address given by <tora>.

<ref>

Reference Number

Reference number to identify all segments of the concatenated SMS (i.e., the number needs to be the same for each segment). If <ieia>=8, then max=255; otherwise, 65535.

0...255

0...65535

<sca>

Service Center Address

GSM 04.11 RP SC address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (refer to command AT+CSCS); type of address given by <tosca>.

<scts>

Service Center Time Stamp

GSM 03.40 TP-Service-Center-Time-Stamp in time-string format (refer <dt>)

<seq> (DAR) new:

Sequence Number

Sequence number of the concatenated SMS beginning with 1. The number must be incremented by one for each segment of the concatenated short message.

<seq>=0 means: ignore the value. This will result in a non-concatenated SMS.

0...255

<sn>

Serial Number

GSM 03.41 CBM Serial Number in integer format.

<st>

Status

GSM 03.40 TP-Status in integer format .

0...255

<stat>

Message status

3GPP 27.005 Interface of SMS and CB. Indicates the status of message in memory.

Description text mode (<mode>=1) PDU mode (<mode>=0) Default

Received unread messages “REC UNREAD”

Received read messages “REC READ”

Stored unsent messages

Stored sent messages

All messages

“STO UNSENT”

“STO SENT”

“ALL”

0

1

2

3

4 for SMS reading commands for SMS writing commands

<toda>

Type of Destination Address

GSM 04.11 TP-Destination-Address Type-of-Address octet in integer format (when first character of <da> is +

(IRA 43) default is 145, otherwise default is 129).

0...255

<tooa>

Type of Originating Address

GSM 04.11 TP-Originating-Address Type-of-Address octet in integer format (default refer <toda>).

<tora>

Type of Recipient Address

GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>).

<tosca>

Type of Service Center Address

GSM 04.11 RP SC address Type-of-Address octet in integer format (default refer <toda>).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 173

Chapter 13 – Short Message Service (SMS) Commands

13.2 AT+CMGC Send an SMS Command

Test Command Syntax: AT+CMGC=?

Response: OK

Write Command Syntax: If text mode (see AT+CMGF=1)

AT+CMGC=<fo>, <ct>[, <pid>[, <mn>[, <da>[, <toda>]]]]<CR> Text can be entered

<CTRL-Z>/<ESC>

Response:

If sending fails

ERROR

ERROR

Write Command Syntax: If PDU mode (see AT+CMGF=0)

AT+CMGC=<length><CR> PDU can be entered <CTRL-Z>/<ESC>

Response:

OK

If sending fails

ERROR

Notes:

• After invoking the commands AT+CMGW, AT+CMGS or AT+CMGC it is necessary to wait for the prompt “>” before entering text or PDU. After the prompt a timer will be started to observe the input.

• At baudrates below 19200 it is recommended to use the line termination character only (refer to ATS3, default

<CR>) before entering the text or PDU. Use of the line termination character followed by the response formatting character (refer to ATS4, default <LF> can cause problems.

13.3 AT+CMGD Delete SMS Message

Description:

Response:

Write command deletes a short message from preferred message storage <mem1> location <index>.

Test Command Syntax: AT+CMGD=?

OK

Write Command Syntax: AT+CMGD=<index>

Response: OK

ERROR

+CMS

Notes:

• If there is no short message stored at the selected index, the response is OK too.

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1 Restricted Access to SIM Data after SIM PIN Authentication.

13.4 AT+CMGF Select SMS Message Format

Description: The write command specifies the input and output format of the short messages.

Test Command Syntax: AT+CMGF=?

Response: +CMGF: (list of supported<mode>s)

OK

Read Command Syntax: AT+CMGF?

Response: +CMGF: <mode>

OK

Write Command Syntax: AT+CMGF=<mode>

Response: OK

Parameter Description:

<mode>

0

1

PDU mode. Default.

Text mode

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 174

Chapter 13 – Short Message Service (SMS) Commands

13.5 AT+CMGL List SMS Messages from Preferred

Store

Description:

‘received read’.

The execute command is the same as the write command with the given default for <stat>.

The write command returns messages with status value <stat> from message storage <mem1> to the TE. If the status of the message is ‘received unread’, the status in the storage changes to

Test Command Syntax: AT+CMGL=?

Response: +CMGL: (list of supported <stat>s)

OK

Exec Command Syntax: AT+CMGL

Response: +CMGL: (see write command for default of <stat>)

OK

Write Command Syntax: AT+CMGL=<stat>

Response: Output if text mode (AT+CMGF=1) and command successful:

For SMS- SUBMITs and/or SMS-DELIVERs

+CMGL: <index>, <stat>, <oa>/<da>, [<alpha>], [<scts>][, <tooa>/<toda>, <length>]

data>

]

OK

For SMS-STATUS-REPORTs

+CMGL: <index>, <stat>, <fo>, <mr>, [<ra>], [<tora>], <scts>, <dt>, <st>

]

OK

For SMS-Commands

+CMGL: <index>, <stat>, <fo>, <ct>

[...

OK

Output if PDU mode AT+CMGF=0 and command successful:

For SMS-SUBMITs and/or SMS-DELIVERs

+CMGL: <index>, <stat>, [<alpha>], <length>

<pdu>

]

OK

If error is related to ME functionality

ERROR

Notes:

• The selected <mem1> can contain different types of SMs (e.g., SMS-DELIVERs, SMS-SUBMITs, SMS-

STATUS-REPORTs and SMS-COMMANDs), the response may be a mix of the responses of different SM types.

TE application can recognize the response format by examining the third response parameter.

• The parameters <ra> and <tora> will only display if parameter <ra> of the AT^SSCONF command is set to 1.

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1 Restricted Access to SIM Data after SIM PIN Authentication.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 175

Chapter 13 – Short Message Service (SMS) Commands

13.6 AT+CMGR Read SMS Messages

Description: The write command returns SMS message with location value <index> from message storage <mem1> to the TE. If status of the message is ‘received unread’, status in the storage changes to ‘received read’.

Test Command Syntax: AT+CMGR=?

Response: OK

Write Command Syntax: AT+CMGR=<index>

Response: Output if text mode (AT+CMGF=1) and command successful:

For SMS-DELIVER

+CMGR : < stat >, < oa >, [< alpha >], < scts >[, < tooa >, < fo >, < pid >, < dcs >, < sca >, < tosca >,

< length >]

<data>

[... ]

OK

For SMS-SUBMIT

+CMGR : < stat >, < da >, [< alpha >][, < toda >, < fo >, < pid >, < dcs >, [< vp >], < sca >, < tosca >,

< length >]

<data>

[... ]

OK

For SMS-STATUS-REPORT

+CMGR: <stat>, <fo>, <mr>, [<ra>], [<tora>], <scts>, <dt>, <st>

<data>

[... ]

OK

For SMS-Commands

+CMGR: <stat>, <fo>, <ct>[, <pid>, [<mn>], [<da>], [<toda>], <length>]

<data>

[... ]

OK

Output if PDU mode (AT+CMGF=0) and command successful:

For SMS-SUBMITs and/or SMS-DELIVERs

+CMGR: <stat>, [<alpha>], <length>

<pdu>

[... ]

OK

ERROR

+CMS ERROR

Notes:

• Response if AT+CMGR is used to read an empty record index: +CMGR: 0,,0.

• Response if AT+CMGR is used to read a non-existent record index: +CMS ERROR: invalid memory index • The parameters <ra> and <tora> will only be displayed if parameter <ra> of the AT^SSCONF command is set to 1.

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1 Restricted Access to SIM Data after SIM PIN Authentication.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 176

Chapter 13 – Short Message Service (SMS) Commands

13.7 AT+CMGS Send SMS Message

Description: The write command transmits a short message from TE to network (SMS-SUBMIT).

After invoking the write command, wait for the prompt “>”, and then start to write the message. To send the message simply enter <CTRL-Z>. After the prompt, a timer will be started to observe the input.

To abort sending use <ESC>. Abortion is acknowledged with “OK”, though the message will not be sent.

The message reference <mr> is returned to the TE on successful message delivery. The value can be used to identify the message in a delivery status report provided as an unsolicited result code.

Test Command Syntax: AT+CMGS=?

Response: OK

Write Command Syntax: If text mode (see AT+CMGF=1)

Response:

AT+CMGS=<da>[, <toda>]<CR> Text can be entered. <CTRL-Z>/<ESC>

+CMGS: <mr>[, <scts>]

OK

If sending fails see notes below.

Write Command Syntax: If PDU mode (see AT+CMGF=0)

Response:

AT+CMGS=<length><CR> PDU can be entered. <CTRL-Z>/<ESC>

+CMGS: <mr>[, <ackpdu>]

OK

If sending fails see notes below.

Notes:

• If sending fails, for example, if a message is too long, the result code depends on the current setting of the

AT^SM20 command:

If the AT^SM20 <CmgwMode> equals 1 (factory default) any failure to send a message is responded with “OK”.

Users should be aware, that despite the “OK” response, the message will not be sent to the subscriber.

If the AT^SM20 <CmgwMode> equals 0 any failure to send a message is responded with “ERROR”.

• If sending fails due to timeout, then AT^SM20 <CmgwMode>=1 causes “+CMS ERROR: Unknown error” to be returned; AT^SM20 <CmgwMode>=0 causes “+CMS ERROR: timer expired” to be returned.

• Note that some providers do not recognize an @ symbol used in a short message. A widely used alternative is typing “*” as defined in GSM 03.40 (GPP TS 23.40).

• All characters entered behind the prompt “>” will be recognized as GSM characters. For example, “Backspace”

(ASCII character 8) does not delete a character, but will be inserted into the short message as an additional physical character. As a result, the character you wanted to delete still appears in the text, plus the GSM code equivalent of the Backspace key.

• In text mode, the maximum length of a short message depends on the used coding scheme: It is 160 characters if the 7 bit GSM coding scheme is used, and 140 characters according to the 8 bit GSM coding scheme.

• At baudrates lower than 19200 it is recommended to use the line termination character only (refer to <n> of

ATS3, default <CR>) before entering text or PDU. Use of the line termination character followed by the response formatting character (see <n> of ATS4, default <LF>) can cause problems.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 177

Chapter 13 – Short Message Service (SMS) Commands

13.8 AT+CMGW Write Short Messages to Memory

Description: The execute and write commands transmit a short message (either SMS-DELIVER or

SMS-SUBMIT) from TE to memory storage <mem2>. Memory location <index> of the stored message is returned. Message status will be set to ‘stored unsent’ unless otherwise given in parameter <stat>.

After invoking the execute or write command wait for the prompt “>” and then start to write the message. To save the message simply enter <CTRL-Z>. After the prompt a timer will be started to observe the input.

To abort writing use <ESC>. Abortion is acknowledged with “OK”, though the message will not be saved.

Test Command Syntax: AT+CMGW=?

Response: OK

Exec Command Syntax: If text mode (see AT+CMGF=1):

AT+CMGW

Response: <CR> Text can be entered. <CTRL-Z>/<ESC>

<index>

OK writing

ERROR

Write Command Syntax: If text mode (see AT+CMGF=1):

[<tooa>/<toda>][, <stat>]] <CR> Text can be entered. <CTRL-

Response:

Z>/<ESC>

+CMGW: <index>

OK

If writing fails see notes below.

Write Command Syntax: If PDU mode (see AT+CMGF=0):

Response:

AT+CMGW=<length>[, <stat>]<CR> PDU can be entered. <CTRL-Z>/<ESC>

+CMGW: <index>

OK

If writing fails see notes below.

Notes:

• If writing fails, for example, if a message is too long, the result code depends on the current setting of the

AT^SM20 command:

If the AT^SM20 <CmgwMode>=1 (factory default) any failure to send a message is responded with “OK”. Users should be aware, that despite the “OK” response, the message will not be written to the selected SMS storage.

If the AT^SM20 <CmgwMode> equals 0 any failure to write a message is responded with “ERROR”.

If writing fails due to timeout, then AT^SM20 <CmgwMode>=1 causes “+CMS ERROR: Unknown error” to be returned; AT^SM20 <CmgwMode>=0 causes “+CMS ERROR: timer expired” to be returned.

• Note that some providers do not recognize an @ symbol used in a short message. A widely used alternative is typing “*” as defined in GSM 03.40 (GPP TS 23.40).

• For baudrates lower than 19200 it is recommended to use the line termination character only (refer to ATS3=

<n>, default <CR>) before entering the text or PDU. Use of the line termination character followed by the response formating character (see ATS4= <n>, default <LF>) may cause problems.

• SMS-COMMANDs and SMS-STATUS-REPORTs cannot be stored in text mode.

• All characters entered behind the “>” prompt will be recognized as GSM characters. For example, “Backspace”

(ASCII character 8) does not delete a character, but will be inserted into the short message as an additional physical character. As a result, the character you wanted to delete still appears in the text, plus the GSM code equivalent of the Backspace key.

• In text mode, the maximum length of a short message depends on the used coding scheme: It is 160 characters if the 7 bit GSM coding scheme is used, and 140 characters according to the 8 bit GSM coding scheme.

• The length of 8-bit data coded short messages has to be greater than 0.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 178

Chapter 13 – Short Message Service (SMS) Commands

13.9 AT+CMSS Send Short Messages from Storage

Description: The write command sends message with location value <index> from message storage

<mem2> to the network (SMS-SUBMIT or SMS-COMMAND). If new recipient address

<da> is given for SMS-SUBMIT, it shall be used instead of the one stored with the message. Reference value <mr> is returned to the TE on successful message delivery.

Value can be used to identify message upon unsolicited delivery status report result code.

If the optional parameter <da> is given, the old status of the short message at <index> remains unchanged (see <stat>).

Test Command Syntax: AT+CMSS=?

Response: OK

Write Command Syntax: If text mode (AT+CMGF=1):

Response:

AT+CMSS=<index>[, <da>[, <toda>]]

+CMSS: <mr>[, <scts>]

OK

If sending fails

ERROR

Write Command Syntax: If PDU mode (AT+CMGF=0):

Response:

AT+CMSS=<index>[, <da>[, <toda>]]

+CMSS: <mr>[, <ackpdu>]

OK

If sending fails

ERROR

+CMS

13.10 AT+CNMA New SMS Message Acknowledge to ME/TE Phase 2+

Description: The write / execute command confirms successful receipt of a new message (SMS-

DELIVER or SMS-STATUSREPORT) routed directly to the TE. TA shall not send another

+CMT or +CDS result code to TE until previous one is acknowledged. If ME does not receive acknowledgment within required time (network time-out), ME sends RP-ERROR to the network. TA shall automatically disable routing to TE by setting both <mt> and <ds> values of AT+CNMI to zero.

Test Command Syntax: AT+CNMA=?

Response: +CNMA: (list of supported <n>s)

OK

Exec Command Syntax: AT+CNMA

Response: OK

ERROR

Write Command Syntax: AT+CNMA=<n>

Response: OK

ERROR

Parameter Description:

<n>

0 Parameter is only required for PDU mode. Command operates similarly as in text mode.

Notes:

• The execute / write command shall only be used when AT+CSMS parameter <service> equals 1 (= phase 2+).

• Both the execute and the write command can be used no matter whether text mode or PDU mode is activated.

• If multiplex mode is activated (AT+CMUX=0) the AT+CNMI parameter will be set to zero on all channels, if one channel fails to acknowledge an incoming message within the required time.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 179

Chapter 13 – Short Message Service (SMS) Commands

13.11 AT+CNMI New Short Message Indication

Description: The write command selects the procedure how the receipt of new short messages from the network is indicated to the TE when TE is active; e.g., the DTR signal is ON. If TE is inactive (e.g., DTR signal is OFF), message receiving should be done as specified in GSM

03.38. If the DTR signal is not available or the state of the signal is ignored (V.250 command AT&D), reliable message transfer can be assured by using AT+CNMA acknowledgment procedure.

The rules <mt>=2 and <mt>=3 for storing received messages are possible only if phase

2+ compatibility is activated with AT+CSMS=1. The parameter <ds>=1 is only available in phase 2+.

Test Command Syntax: AT+CNMI=?

Response: +CNMI: (list of supported<mode>s), (list of supported <mt>s), (list of supported <bm>s),

(list of supported <ds>s), (list of supported <bfr>s)

OK

Read Command Syntax: AT+CNMI?

Response: +CNMI: <mode>, <mt>, <bm>, <ds>, <bfr>

OK

Write Command Syntax: AT+CNMI=[<mode>][, <mt>][, <bm>][, <ds>][, <bfr>]

Response: OK

ERROR

Parameter Descriptions:

<mode>

0

1

2

3

<mt>

1

2

3

Buffer unsolicited result codes in the TA. If TA result code buffer is full, indications can be buffered in some other place or the oldest indications may be discarded and replaced with the new received indications. Default.

Discard indication and reject new received message unsolicited result codes when TA-TE link is reserved (e.g., in on-line data mode). Otherwise, forward them directly to the TE.

Buffer unsolicited result codes in the TA when TA-TE link is reserved (e.g., in on-line data mode) and flush them to the TE after reservation. Otherwise, forward them directly to the TE.

Forward unsolicited result codes directly to the TE. TA-TE link specific in-band technique used to embed result codes and data when TA is in on-line data mode.

Rules for storing received short messages depend on the relevant data coding method (refer to

GSM 03.38), preferred memory storage (AT+CPMS) setting and this value.

Note: If AT command interface is acting as the only display device, the ME must support storage of class 0 messages and messages in the message waiting indication group (discard message)

[0](&F) No SMS-DELIVER indications are routed to the TE.

If SMS-DELIVER is stored in ME/TA, indication of the memory location is routed to the TE using unsolicited result code:

SMS-DELIVERs, except class 2 messages and messages in the message waiting indication group (store message) are routed directly to the TE using unsolicited result code:

Class 3 SMS-DELIVERs are routed directly to the TE using unsolicited result codes defined in

<mt>=2. Messages of other data coding schemes result in indication as defined in <mt>=1.

<bm>

0

2

3

Rules for storing received CBMs depend on the relevant data coding method (refer to GSM

03.38), the setting of Select CBM Types (AT+CSCB) and this value:

No CBM indications are routed to the TE. Default.

New CBMs are routed directly to the TE using unsolicited result code:

Class 3 CBMs are routed directly to TE using unsolicited result codes defined in <bm>=2.

<ds>

0

1

2

No SMS-STATUS-REPORTs are routed to the TE. Default.

SMS-STATUS-REPORTs are routed to the TE using unsolicited result code:

If SMS-STATUS-REPORT is routed into ME/TA, indication of the memory location is routed to the TE using unsolicited result code.

<bfr>

1 TA buffer of unsolicited result codes defined within this command is cleared when <mode> changes from 0 to 1...3.

<index>

Integer type; value in the range of location numbers supported by the associated memory.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 180

Chapter 13 – Short Message Service (SMS) Commands

Unsolicited Result Codes:

URC 1

<mt>=1:

+CMTI: <mem3>, <index>

Indicates that new message has been received

URC 2

<mt>=2 (PDU mode enabled):

+CMT: <length><CR><LF><pdu>

Indicates that new message has been received

URC 3

<mt>=2 (text mode enabled):

+CMT: <oa>, <scts>[, <tooa>, <fo>, <pid>, <dcs>, <sca>, <tosca>, <length>]<CR><LF><data>

Indicates that new message has been received

URC 4

<bm>=2 (PDU mode enabled):

+CBM: <length><CR><LF><pdu>

Indicates that new cell broadcast message has been received

URC 5

<bm>=2 (text mode enabled):

+CBM: <sn>, <mid>, <dcs>, <page>, <pages><CR><LF><data>

Indicates that new cell broadcast message has been received

URC 6

<ds>=1 (PDU mode enabled):

+CDS: <length><CR><LF><pdu>

Indicates that new SMS status report has been received

URC 7

<ds>=1 (text mode enabled):

+CDS: <fo>, <mr>[, <ra>][, <tora>], <scts>, <dt>, <st>

Indicates that new SMS status report has been received

URC 8

<ds>=2:

+CDSI: <mem3>, <index>

Indicates that new SMS status report has been received

Notes:

• Each time a short message or Cell Broadcast Message is received, the Ring Line goes Logic “1” for one second.

• Parameters <mt>=2,3 and <ds>=1 are only available with GSM phase 2+ (see AT+CSMS=1). Incoming SMs or

Status Reports have to be acknowledged with AT+CNMA=0 when using these phase 2+ parameters.

• Requirements specific to Multiplex mode:

In multiplex mode (AT+CMUX=0) only one channel can use a phase 2+ parameter. The parameter for <mt> and

<ds> on the other channels have to be set to zero. If either a SM or a Status Report is not acknowledged, all

AT+CNMI parameter in all channels will be set to zero.

• If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0), avoid different settings for routing and indicating short messages. For example, if messages shall be routed directly to one instance of the TE (set with

AT+CNMI, AT^SSDA), it is not possible to activate the presentation of URCs with AT+CMER or AT+CNMI on another instance. Any attempt to activate settings that conflict with existing settings on another interface, will result in CME ERROR, or accordingly CMS ERROR.

• Handling of Class 0 short messages:

If the host application is provided with a display and AT^SSDA=1 has been set Class 0 short messages can be displayed immediately.

If the host application does not include a display, ME handles Class 0 short messages as though there was no message class; i.e., it will ignore bits 0 and 1 in the <dcs> and normal rules for exceeded memory capacity shall apply. This approach is compliant with GSM 03.38 .

• The parameters <ra> and <tora> will only be displayed if <ra> of the AT^SSCONF command is set to 1.

• If either a SM or a Status Report is not acknowledged, all AT+CNMI parameter in all channels will be set to zero.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 181

Chapter 13 – Short Message Service (SMS) Commands

13.12 AT+CPMS Preferred SMS Message Storage

Description: The write command selects memory storages <mem1>,<mem2>, <mem3> to be used for reading, writing, etc.

Test Command Syntax: AT+CPMS=?

Response: +CPMS: (list of supported <mem1>s), (list of supported <mem2>s), (list of supported

<mem3>s)

OK

Read Command Syntax: AT+CPMS?

Response: +CPMS: <mem1>, <used1>, <total1>, <mem2>, <used2>, <total2>, <mem3>, <used3>,

<total3>

OK

ERROR

ERROR

ERROR

Write Command Syntax: AT+CPMS=<mem1>[, <mem2>[, <mem3>]]

Response: +CPMS: <used1>, <total1>, <used2>, <total2>, <used3>, <total3>

OK

ERROR

ERROR

Parameter Descriptions:

<used1>

<used2>

<used3>

<total1>

<total2>

<total3>

Number of messages currently in <mem1>

Number of messages currently in <mem2>

Number of messages currently in <mem3>

Number of messages storable in <mem1>

Number of messages storable in <mem2>

Number of messages storable in <mem3>

Notes:

• The Mobile Equipment storage “ME” offers space for 25 short messages, see <mem1>.

• “MT” is the sum of “ME” (= 25 locations) and “SM” (capacity varies with SIM card). The indices <index> of the

“MT” storage are dependent on the order selected with AT^SSMSS

• The <mem1>, <mem2> and <mem3> parameter will be stored in non-volatile memory.

• The user should be aware that the setting “MT” involves “ME” and “SM”, with “ME” being filled up first. If the “ME” storage is full, the Multi-Tech wireless modem will proceed with the “SM” storage.

Incoming Class 1 short messages (ME specific) will be preferably stored to “ME” and may be transferred to the

“SM” storage if “ME” is used up.

Incoming Class 2 messages (SIM specific) will be stored to the SIM card only, no matter whether or not there is free “ME” space. As a result, the ^SMGO: 2 indication (see AT^SMGO) may be presented without prior indication of ^SMGO: 1. For more information regarding SIM and ME specific message classes refer to <dcs> and the following specifications: GSM 03.38 and 3GPP TS23038.

• Multiplexer: In Multiplex mode or when the two physical serial interfaces are connected, the parameter <mem3> will be the same on all instances, but the setting of <mem1> and <mem2> may vary on each channel / interface.

As a result, changes on parameters <mem1> and/or <mem2> before activating the multiplexer or different values for other instances can result in undesirable behavior; for example, different output for AT+CMGL.

• While <mem3> equals “SM” and <mem1> equals “ME” it is possible that, after deleting short messages from

“ME”, the freed space on “ME” is reclaimed for new incoming short messages, when there is no space left on the

“SM” storage. As it is often the clients concern to have received short messages stored only to the SIM card, inconsistent settings should be generally avoided. This can be achieved simply by using the same parameter for all memory indices.

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

• The indexes <index> of the storage are dependent on the order selected with AT^SSMSS.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 182

Chapter 13 – Short Message Service (SMS) Commands

13.13 AT+CSCA SMS Service Center Address

Description: The write command updates the SMSC address, through which mobile originated SMs are transmitted. In text mode, setting is used by send and write commands. In PDU mode, setting is used by the same commands, but only when the length of the SMSC address coded into the <pdu> parameter equals zero.

Test Command Synatx: AT+CSCA=?

Response: OK

Read Command Syntax: AT+CSCA?

Response: +CSCA: <sca>, <tosca>

OK

Write Command Syntax: AT+CSCA=<sca>[, <tosca>]

Response: OK

Notes:

• In case of using no parameter after AT+CSCA= the content of <sca> will be deleted.

• This command writes the service center address to non-volatile memo.

• The SMS service center address should be entered as specified by the service provider.

13.14 AT+CSCB Select Cell Broadcast Message

Indication

Description: The Test command returns supported modes as a compound value.

Write command selects which types of CBMs are to be received by the ME.

Test Command Syntax: AT+CSCB=?

Response: +CSCB: (list of supported <mode>s)

OK

Read Command Syntax: AT+CSCB?

Response: +CSCB: <mode>, <mids>, <dcss>

OK

Write Command Syntax: AT+CSCB=[<mode>[, <mids>[, <dcss>]]]

Response: OK

Parameter Descriptions:

<mode>

Message mode

0

1

Accept messages that are defined in <mids> and <dcss>. Default.

Forbid messages that are defined in <mids> and <dcss>

<mids>

Cell Broadcast Message ID specification

• For <mode>=0: Six different possible combinations of CBM IDs (e.g., “0,1,5,320-478,922,2000-3000”), default is empty string.

In certain configurations, such as using SIMs that contain data in Elementary File EF-CBMID (Cell

Broadcast Message Identifier for Data download), less than six combinations may be available.

To access a SIM’s Elementary File data refer to command AT+CRSM.

• For <mode>=1: One CBM ID or range of IDs (e.g., “320-478”) default is empty string.

<dcss>

CBM data coding scheme specification

All different possible combinations of CBM data coding schemes (e.g., “0-3,5”). Using default empty string leads to get all CBMs independent of their dcss.

A given <dcss> replaces any former value and is used for consecutive requests.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 183

Chapter 13 – Short Message Service (SMS) Commands

13.15 AT+CSDH Show SMS Text Mode Parameters

Description: The write command sets whether or not detailed header information is shown in text mode result codes.

Test Command Syntax: AT+CSDH=?

Response: +CSDH: ((list of supported <show>s)

OK

Read Command Syntax: AT+CSDH?

Response: +CSDH:<show>

OK

Write Command Syntax: AT+CSDH=<show>

Response: +CSDH: <show>

OK

Parameter Description:

<show>

0

1

Do not show header values defined in commands AT+CSCA and AT+CSMP (<sca>,

<tosca>,<fo>,<vp>, <pid> and <dcs>) nor <length>, <toda> or <tooa> in “+CMTI”, AT+CMGL,

AT+CMGR result codes for SMS-DELIVERs and SMS-SUBMITs in text mode; for SMS-

COMMANDs in +CMGR result code, do not show <pid>,<mn>,<da>, <toda>, <length> or

<cdata>. Default.

Show the values in result codes.

13.16 AT+CSMP Set SMS Text Mode Parameters

Description: The write command selects values for additional parameters needed when the short message is sent to the network or placed in a storage and when text format message mode is selected.

It is possible to set the validity period starting from the time when the short message is received by the SMSC (<vp> is in range 0...255) or to define the absolute time of the validity period termination (<vp> is a string). The format of <vp> is given by <fo>. If the TA supports the enhanced validity period format, it will be given as a hexadecimal coded string (e.g., <pdu>) with quotes.

Test Command Syntax: AT+CSMP=?

Response: OK

Read Command Syntax: AT+CSMP?

Response: +CSMP:<fo>, <vp>/ <scts>, <pid>, <dcs>

OK

Write Command Syntax: AT+CSMP=<fo>[, <vp>/<scts>[, <pid>[, <dcs>]]]

Response: +CSMP: <index>

OK

If sending fails: ERROR or +CMS ERROR

Parameter Descriptions:

<fo>

First Octet

Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17),

SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format.

0....255 Default = 17.

<vp>

Depending on SMS-SUBMIT <fo> setting: GSM 03.40 TP-Validity-Period either in integer format or in time string format (refer <dt>).

0....255 Default = 167.

<dcs>

Data Coding Scheme

GSM 03.38 SMS Data Coding Scheme or Cell Broadcast Data Coding Scheme in integer format .

0...247 Default = 0.

<pid>

Protocol Identifier

GSM 03.40 TP-Protocol-Identifier in integer format.

0...255 Default = 0.

Notes:

• When storing a SMS DELIVER from the TE to the preferred memory storage in text mode (using the AT+CMGW write command), <vp> field can be used for <scts>.

• The command writes the parameters to the non-volatile memory.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 184

Chapter 13 – Short Message Service (SMS) Commands

13.17 AT+CSMS Select Message Service

Test Command Synatx: AT+CSMS=?

Response: +CSMS: (list of supported<service>s)

OK

Read Command Syntax: AT+CSMS?

Response: +CSMS: <service>, <mt>, <mo>, <bm>

OK

Write Command Syntax: AT+CSMS=<service>

Response: +CSMS: <mt>, <mo>, <bm>

OK

ERROR

ERROR

Parameter Descriptions:

<service>

0

1

GSM 03.40 and GSM 03.41 (The syntax of SMS AT commands is compatible with GSM 07.05

Phase 2 version 4.7.0. Phase 2+ features which do not require new command syntax may be supported; e.g., correct routing of messages with new Phase 2+ data coding schemes). Default.

GSM 03.40 and GSM 03.41 (the syntax of SMS AT commands is compatible with GSM 07.05

Phase 2+ version; the requirement of <service> setting 1 is mentioned under corresponding command descriptions).

<mt>

Mobile Terminated Messages:

0

1

Type not supported

Type supported

<mo>

Mobile Originated Messages:

0

1

Type not supported

Type supported

<bm>

Broadcast Type Messages:

0

1

Type not supported

Type supported

Notes:

• If CSMS mode is switched from Phase 2+ to Phase 2 and one or more AT+CNMI Parameter are Phase 2+ specific a ‘+CMS ERROR: unknown error’ will appear. It is recommended to switch the AT+CNMI Parameters to

Phase 2 specific values before entering Phase 2.

• Phase 2+ (<service>=1) must be set before the following features can be used:

∗ Configuring procedures for indicating received short messages with the AT+CNMI parameters <mt>=2 or

<mt>=3 and <ds>=1.

∗ Acknowledging incoming short messages with AT+CNMA.

∗ Receiving Status Reports and acknowledging them with AT+CNMA.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 185

Chapter 13 – Short Message Service (SMS) Commands

13.18 AT^SCML List Concatenated Short Messages from Preferred Store

Description: The execute command is the same as the write command with the given default for

<stat>.

write command returns messages with status value <stat> from message storage

<mem1> to the TE. If status of the message is ‘received unread’, status in the storage changes to ‘received read’.

Test Command Syntax: AT^SCML=?

Response(s): ^SCML: (list of supported <stat>s)

OK

Exec Command Syntax: AT^SCML

Response(s): ^SCML: (see write command for default of <stat>)

OK

Write Command Syntax: AT^SCML=<stat>

Response(s): Output if text mode (AT+CMGF=1) and command successful:

For SMS-SUBMITs and/or SMS-DELIVERs

^SCML: <index>, <stat>, <oa>/<da>, [<alpha>], [<scts>][, <tooa>/<toda>, <length>][,

<seq>, <max>, <ieia>, <ref>]

<data>

OK

For SMS-STATUS-REPORTs

^SCML: <index>, <stat>, <fo>, <mr>, [<ra>], [<tora>], <scts>, <dt>, <st>

[...

OK

For SMS-Commands

^SCML: <index>, <stat>, <fo>, <ct>

]

OK

Output if PDU mode (AT+CMGF=0) and command successful:

For SMS- SUBMITs and/or SMS-DELIVERs

^SCML: <index>, <stat>, [<alpha>], <length>

<pdu>

[... ]

OK

If error is related to ME functionality

ERROR

+CMS

Note

• See the Notes section of the AT+CMGL command.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 186

Chapter 13 – Short Message Service (SMS) Commands

13.19 AT^SCMR Read Concatenated Short

Messages

Description: The write command returns the message with location value <index> from message storage <mem1> to the TE.

If status of the message is ‘received unread’, status in the storage changes to ‘received read’. See notes of AT+CMGR.

Test Command Syntax: AT^SCMR=?

Response(s): OK

Write Command:

Response(s):

AT^SCMR=<index>

Output if text mode (AT+CMGF=1) and command successful:

For SMS-DELIVER

^SCMR: <stat>, <oa>, [<alpha>], <scts>[, <tooa>, <fo>, <pid>, <dcs>, <sca>, <tosca>,

<length>][, <seq>, <max>, <ieia>, <ref>]

<data>

[...

OK

For SMS-SUBMIT

^SCMR: <stat>, <da>, [<alpha>][, <toda>, <fo>, <pid>, <dcs>, [<vp>], <sca>, <tosca>,

<length>][, <seq>, <max>, <ieia>, <ref>]

<data>

]

OK

For SMS-STATUS-REPORT

^SCMR: <stat>, <fo>, <mr>, [<ra>], [<tora>], <scts>, <dt>, <st>

<data>

]

OK

For SMS-Commands

^SCMR: <stat>, <fo>, <ct>[, <pid>, [<mn>], [<da>], [<toda>], <length>]

<data>

]

OK

Output if PDU mode (AT+CMGF=0) and command successful:

For SMS-SUBMITs and/or SMS-DELIVERs

^SCMR: <stat>, [<alpha>], <length>

<pdu>

]

OK

ERROR

ERROR

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 187

Chapter 13 – Short Message Service (SMS) Commands

13.20 AT^SCMS Send Concatenated Short

Messages

Description: Sending a concatenated message is similar to sending a “normal” message, except that each segment of the concatenated message must be identified by the additional parameters <seq>, <ieia> and <ref>. To send all segments of the message one by one, the AT^SCMS write command must be executed for each segment.

The write command transmits one segment of a concatenated short message from TE to network (SMS-SUBMIT). After invoking the write command wait for the prompt “>” and then start to write the message. To send the message simply enter <CTRL-Z>. After the prompt a timer will be started to observe the input.

To abort sending use <ESC>. Abortion is acknowledged with “OK”, though the message will not be sent.

The message reference <mr> is returned to the TE on successful message delivery. The value can be used to identify the message in a delivery status report provided as an unsolicited result code.

Test Command Syntax: AT^SCMS=?

Response(s): OK

Write Command Syntax: Command syntax for text mode (see AT+CMGF=1):

AT^SCMS=<da>[, <toda>], <seq>, <max>, <ieia>, <ref><CR> Text can be entered

<CTRL-Z>/<ESC>

Response(s): +CMGS: <mr>[, <scts>]

OK

If sending fails: ERROR or +CMS ERROR

Notes:

• See notes provided for AT+CMGS.

• Command is only available if AT+CMGF=1.

13.21 AT^SCMW Write Concatenated Short

Messages to Memory

Description: Writing a concatenated message to the memory is similar to writing a “normal” message, except that each segment of the concatenated message must be identified by the additional parameters <seq>, <ieia> and <ref>.

To store all segments of the message one by one, the AT^SCMW write command must be executed for each segment.

The write command transmits one segment of a concatenated SMS (either SMS-

DELIVER or SMS-SUBMIT) from TE to memory storage <mem2>. Memory location

<index> of the stored message is returned. Message status will be set to ‘stored unsent’ unless otherwise given in parameter <stat>.

Test Command Syntax: AT^SCMW=?

Response(s): OK

Write Command Syntax: If text mode (see AT+CMGF=1)

AT^SCMW=<oa>/<da>, can be entered. <CTRL-Z>/<ESC>

Response(s): ^SCMW: <index>

OK

If writing fails: ERROR or +CMS ERROR

Notes:

• Command is only available if AT+CMGF=1.

• To send or delete a concatenated short message please use the known SMS commands, see AT+CMSS for sending and AT+CMGD for deleting.

• See notes provided for AT+CMGW.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 188

Chapter 13 – Short Message Service (SMS) Commands

13.22 AT^SLMS List SMS Memory Storage

Description: AT^SLMS indicates the maximum capacity of each SMS storage type and the number of locations currently used.

Test Command Syntax: AT^SLMS=?

Response: OK

Exec Command Syntax: AT^SLMS

Response: ^SLMS: “MT”,<total3>, <used3>

^SLMS: “SM”,<total1>, <used1>

^SLMS: “ME”,<total2>, <used2>

OK

ERROR

ERROR

Parameter Descriptions:

<total1>

Maximum number of messages storable in the SMS memory of the SIM (physical storage “SM”).

<total2>

Maximum number of messages storable in the SMS memory of the Mobile Equipment (physical storage “ME”).

<total3>

Sum of “SM” and “ME”, indicated as “MT”. Maximum number of all messages storable in the SIM memory and the Mobile Equipment memory.

<used1>

Number of messages currently stored in the SMS memory of the SIM (physical storage “SM”).

<used2>

Number of messages currently stored in the SMS memory of the Mobile Equipment (physical storage “ME”).

<used3>

Concatenated logical SMS storages of SIM (“SM”) and Mobile Equipment (“ME”). Sum of all messages currently stored, indicated as “MT”.

Note:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

13.23 AT^SMGL List Short Messages from

Preferred Store without Setting Status to REC

READ

Description: The execute command is the same as the write command, but uses the given default of

<stat>.

write command allows to select a status type and lists, from the message storage

<mem1>, all messages that currently have the specified <stat>. The major difference over the standard command AT+CMGL is that the status of the listed messages remains unchanged (unread remains unread).

Test Command Syntax: AT^SMGL=?

Response: same as AT+CMGL

Exec Command Syntax: AT^SMGL

Response: ^SMGL: (For default values of <stat>, see Section 13.1 “SMS Parameters”.)

OK

Write Command Syntax: AT^SMGL=<stat>

Response: same as AT+CMGL

Notes:

• The selected <mem1> can contain different types of SMs (e.g., SMS-DELIVERs, SMS-SUBMITs, SMS-

STATUS-REPORTs and SMS-COMMANDs). The response may be a mix of the responses of different SM types. TE application can recognize the response format by examining the third response parameter.

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 189

Chapter 13 – Short Message Service (SMS) Commands

13.24 AT^SMGO Set or Query SMS Overflow

Pesentation Mode or Query SMS Overflow

Description: The read command returns overflow presentation mode and SMS overflow status.

The write command sets overflow presentation mode.

Test Command:

Response:

AT^SMGO=?

^SMGO: (list of supported<n>s)

OK

Read Command: AT^SMGO?

Response: ^SMGO: <n> , <mode>

OK

ERROR

ERROR

Write Command:

Response:

AT^SMGO=<n>

OK

ERROR

ERROR

Parameter Descriptions:

<n>

SMS overflow presentation mode.

0 Disable.

1 Enable

<mode>

SMS overflow status

0

1

2

Space available.

SMS buffer full. The buffer for received short messages is <mem3>. See AT+CPMS.

Buffer full and new message waiting in SC for delivery to phone.

Unsolicited Result Code:

SMS buffer change:

^SMGO: <mode>

Status of SMS buffer has changed.

Notes:

• Incoming short messages with message class 1 (ME specific short messages) or class 2 (SM specific short messages), see <dcs> in GSM 03.38, will be stored either in “ME” or in “SM” storage. Therefore the “^SMGO:

2” indication could occur, without issuing the indication “^SMGO: 1” before. The indication “^SMGO: 1” means that both buffers (“ME” and “SM”) are full.

• For more information regarding SIM and ME specific message classes refer to <dcs> and the following specifications: GSM 03.38 and 3GPP TS 23.038.

13.25 AT^SMGR Read Short Message without

Setting Status to REC READ

Description: The AT^SMGR command is a specific command which has the same syntax as

AT+CMGR. The only functional difference is that the status “REC UNREAD” of a short message is not overwritten to “REC READ”.

Test Command Syntax: AT^SMGR=?

Response: ^SMGR:

OK

Write Command Syntax: AT^SMGR=<index>

Response: see AT+CMGR

Note:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 190

Chapter 13 – Short Message Service (SMS) Commands

13.26

AT^SSCONF SMS Command Configuration

Description: AT^SSCONF controls details of some SMS releated commands. Please note that

AT^SSCONF settings are stored volatile; i.e., after restart or reset the default values will be restored.

Test Command Syntax: AT^SSCONF=?

Response: ^SSCONF:list of supported <ra>s

OK

Read Command Syntax: AT^SSCONF?

Response: ^SSCONF:<ra>

OK

Write Command Syntax: AT^SSCONF=<ra>

Response: OK

Parameter Description:

<ra>

Display recipient address

0

1

The Multi-Tech wireless modem does not display <ra> and <tora>. These parameters are used with the result codes of AT+CMGL, AT^SMGL, AT+CMGR, AT^SMGR and the URC “+CDS”.

Default.

Multi-Tech wireless modem displays <ra> and <tora>.

13.27 AT^SSDA Set SMS Display Availability

Description: This command allows to notify the Multi-Tech wireless modem of its controlling application’s capability to immediately display incoming SMS on a display.

If the application is able to display incoming short messages, a class 0 message shall be displayed immediately.

However, if it does not, class 0 messages shall be treated as if no message class is determined

(GSM 03.38[17]).

The effect of this command if <da>=1 is to determine the behavior of parameter <mt> of

AT+CNMI:

If multiplex mode is enabled (AT+CMUX) and <da>=1 with <mt>=1 is set on any logical channel, all other channels have to use <mt>=0.

Test Command Syntax: AT^SSDA=?

Response: ^SSDA:list of supported <da>s

OK

Read Command Syntax: AT^SSDA?

Response:

The read command returns ME’s current capability setting.

^SSDA:<da>

OK

Write Command Syntax: AT^SSDA=<da>

Response: OK

Parameter Description:

<da>

Display Availability

0

1

Application is not able to display incoming short message. Default.

Application is able to display incoming short message.

Note: If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0) avoid different settings for routing and indicating short messages. For example, if messages shall be routed directly to one instance of the TE (set with AT+CNMI, AT^SSDA), it is not possible to activate the presentation of URCs with AT+CMER or AT+CNMI on another instance. Any attempt to activate settings that conflict with existing settings on another interface, will result in CME ERROR, or accordingly CMS ERROR.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 191

Chapter 13 – Short Message Service (SMS) Commands

13.28 AT^SSMSS Set Short Message Storage

Sequence

Description: The short message storage “MT” (see AT+CPMS) is a logical storage. It consists of two physical storages “ME” and “SM”. This command allows to select the sequence of addressing this storage.

Test Command Syntax: AT^SSMSS=?

Response: ^SSMSS: (list of supported) <seq>s

Read Command Syntax: AT^SSMSS?

Response: ^SSMSS: <seq>

OK

Write Command Syntax: AT^SSMSS=<seq>

Response: OK

Parameter Description:

<seq>

MT sequence

0

1

Note:

“MT” storage is “ME” then “SM”. Default.

“MT” storage is “SM” then “ME”

Access to the SIM storage is faster. For compatibility with previous software re-leases, the

“MT” sequence <seq>=0 is the factory default.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 192

Chapter 14 – SIM-Related Commands

Chapter 14. SIM-Related Commands

The AT commands described in this chapter are related to the Subscriber Identity Module (SIM) connected to the

Multi-Tech wireless modem.

If using data from the SIM please bear in mind that the content of all Elementary Files is subject to change at any moment!

This is true because the network can change the SIM’s data in the background via the SIM Application Toolkit (SAT) procedure “Data download to SIM”. For a detailed description please refer to GSM 11.14.

To get informed that changing Elementary Files has taken place the TA needs to hook to the SAT Proactive

Command “REFRESH”. To achieve this, the AT command interface of SAT, i.e., Remote-SAT, needs to be activated.

An overview is given at Chapter 15, SIM Application Toolkit (SAT) Commands, additional information is available with the document “Remote-SAT User Guide” .

14.1 AT+CRSM Restricted SIM Access

Description: AT+CRSM offers easy access of the Elementary Files on the SIM. Access to the SIM database is restricted to the commands which are listed at <command>. However, additional SIM commands are available via AT^SXSM.

All parameters of AT+CRSM are used as specified by GSM 11.11 [21]. The Multi-Tech wireless modem handles internally all required SIM interface locking and file selection routines.

As response to the command, the Multi-Tech wireless modem sends the actual SIM information parameters and response data. Error result code “+CME ERROR” may be returned if the command cannot be passed to the SIM; e.g., if the SIM is not inserted.

However, failure in the execution of the command in the SIM is reported in <sw1> and

<sw2> parameters.

AT+CRSM requires PIN authentication. However, using <command> “READ BINARY” and <command> “READ RECORD” is possible before PIN authentication and if the SIM is blocked (state after three failed PIN authentication attempts) to access the contents of the following Elementary Files:

EF Symbol

EF ICCID

EF

ELP

EF Name

ICC identification

Extended language preference

EF ID (hex.) EF ID (dec.)

2FE2

2F05

12258

12037

EF

LP

Language 28421

EF

SPN

Service provider name

EF

AD

Administrative

6F46 28486

EF Phase Phase

EF ECC Emergency call codes

6FAE 28590

6FB7 28599

Please beware of possible changes to Elementary Files by the network at any time, refer to Chapter 14, SIM-Related Commands.

Test Command Syntax: AT+CRSM=?

Response: OK

Write Command Syntax: AT+CRSM=<command>[, <fileID>[, <P1>, <P2>, <P3>[, <data>]]]

Response: +CRSM: <sw1>,<sw2>[,<response>]

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<command>

SIM command number.

176

178

192

214

220

242

READ BINARY

READ RECORD

GET RESPONSE

UPDATE BINARY

UPDATE RECORD

STATUS

<fileID>

Identifier for an elementary data file on SIM, if used by <command>.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 193

Chapter 14 – SIM-Related Commands

<P1>, <P2>, <P3>

Parameters to be passed on by the Multi-Tech wireless modem to the SIM.

0...255

<data>

Information which shall be written to the SIM (hexadecimal character format).

<sw1>, <sw2>

Status information from the SIM about the execution of the actual command. It is returned in both cases, on successful or failed execution of the command.

0...255

<response>

Response data in case of a successful completion of the previously issued command.

“STATUS” and “GET RESPONSE” commands return data, which gives information about the currently selected elementary data field. This information includes the type of file and its size.

After “READ BINARY” or “READ RECORD” commands the requested data will be returned.

<response> is empty after “UPDATE BINARY” or “UPDATE RECORD” commands.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 194

Chapter 14 – SIM-Related Commands

14.2 AT^SXSM Extended SIM Access

Description: AT^SXSM extends AT+CRSM with additional SIM commands.

All parameters of AT^SXSM are used as specified by GSM 11.11. The Multi-Tech wireless modem handles internally all required SIM interface locking and file selection routines.

The Multi-Tech wireless modem may return error result code “+CME ERROR” if the command cannot be passed to the SIM; e.g., if no SIM is inserted. However, errors related to SIM action are reported in <sw1> and <sw2> parameters as defined in GSM 11.11.

Test Command Syntax: AT^SXSM=?

Response: OK

Write Command Syntax: AT^SXSM=<command>[, <fileID>[, <P1>, <P2>, <P3>[, <data>]]]

Response: ^SXSM: <sw1>, <sw2>[,<response>]

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<command>

136 RUN GSM ALGORITHM

Start the authentication mechanism and cipher key generation on the SIM. It runs the algorithms A3 and A8 using a 16 byte random number and the subscriber authentication key Ki, which is stored in the SIM.

<fileID>

Identifier for an elementary data file on SIM, if used by <command>.

<P1>, <P2>, <P3>

Parameters to be passed on by the Multi-Tech wireless modem to the SIM.

<data>

If <command>=136 (RUN GSM ALGORITHM):

16 byte random number.

<sw1>, <sw2>

Status information from the SIM about the execution of the actual command. It is returned in both cases, on successful or failed execution of the command.

0...255

<response>

Response in case of a successful completion of the previously issued SIM command.

If <command>=136 (RUN GSM ALGORITHM):

The Multi-Tech wireless modem returns SRES and cipher key Kc as calculated by the SIM.

Byte(s) Description

1 - 4

Length

SRES - Signed RESponse 4

5 - 12 Kc - Cipher Key 8

Example:

Use <command>=136 (RUN GSM ALGORITHM) to obtain SRES and cipher key Kc values as calculated by the SIM. at^sxsm=136,,0,0,16,”0011223 Start SIM command “RUN GSM ALGORITHM” with 16 byte random number.

3445566778899AABBCCDDEEFF”

^SXSM: SRES (bytes 1-4) and Cypher Key Kc (bytes 5-12) values as returned by the SIM.

144,0,00112233445566778899AA

BB

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 195

Chapter 14 – SIM-Related Commands

14.3 AT^SCKS Query SIM and Chip Card Holder

Status

Description: This command controls the SIM connection presentation mode and queries the connection status of the SIM and the card holder tray of the Multi-Tech wireless modem.

The read command returns the URC presentation mode and the status of the SIM card connection.

write command enables or disables the presentation of URCs to report whether or not the SIM card is connected.

If the ME is powered down or reset (AT+CFUN or AT^SMSO) the current presentation mode setting <mode> will not be retained. Therefore the setting <mode>=1 needs to be restored after power on the Multi-Tech wireless modem or may be saved in the user profile (AT&W).

Test Command Syntax: AT^SCKS=?

Response: ^SCKS:(list of supported <mode>s)

OK

Read Command Syntax: AT^SCKS?

Response: ^SCKS: <mode>, <SimStatus>

OK

ERROR

+CME ERROR: <err>

Write Command Style: AT^SCKS=<mode>

Response: OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<mode>

0

1

<SimStatus>

0

1

Suppress unsolicited result codes. Default.

Output unsolicited result codes

Card holder tray removed or SIM connection error

SIM inserted(refer to note)

Unsolicited Result Code:

^SCKS: <SimStatus> During startup, and if the Multi-Tech wireless modem’s SIM connection status has changed an unsolicited result code (URC) is issued.

Notes:

• <SimStatus> reflects the status of the SIM and the cardholder tray. Therefore, if an empty SIM card tray is inserted, two URCs will be presented, indicating status 1 followed by 0; i.e., a SIM is inserted into the cardholder tray but no SIM connection could be established.

• The SIM interface HW has been deactivated to prevent possible damage (e.g., if a SIM with invalid or unsupported electrical specifications has been detected). The SIM interface can be reactivated only with a restart of the module; e.g., with “AT+CFUN= n,1”

Example: AT^SCKS=1

OK

Activates the presentation of unsolicited result codes

Now, after inserting an empty card tray, the following URCs appear:

^SCKS: 1

^SCKS: 0

Tray connected

No SIM card found

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 196

Chapter 14 – SIM-Related Commands

14.4 AT^SSET Indicate SIM Data Ready

Description: After power-up and personalization (PIN entry if required) the ME starts reading data from

SIM. The AT^SSET command controls the presentation of the “^SSIM READY” URC that indicates on the corresponding serial channel when the ME has finished reading SIM data.

See Section 20.1, Restricted Access to SIM Data after SIM Authentication.

Test Command Syntax: AT^SSET=?

Response(s): ^SSET:(list of supported <n>s)

OK

Read Command Syntax: AT^SSET?

Response(s): ^SSET: <n>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT^SSET=[<n>]

Response(s): OK

ERROR

+CME ERROR: <err>

Unsolicited Result Code:

^SSIM READY The URC acknowledges to the user that SIM data is accessible. Before that, any attempt to access one of the phonebooks, view SMS or access SIM data will result in “+CME

ERROR: 14” (SIM busy).

Parameter Description:

<n>

URC presentation mode

0 Disable URC “^SSIM READY” indication. Default.

Enable URC “^SSIM READY” indication. 1

14.5 AT^SCID Display SIM Card Identification

Number

Description: TA returns the card identification number in SIM (SIM file EFICCID, see GSM 11.11

Chap.10.1.1) as string type.

Test Command Syntax: AT^SCID=?

Response: OK

Exec Command Syntax: AT^SCID

Response: ^SCID: <cid>

OK

ERROR

+CME ERROR: <err>

Parameter Description:

<cid> Card identification number of SIM card.

14.6 AT+CXXCID Display Card ID

Description: TA returns the card identification number in SIM (SIM file EF ICCID, see GSM 11.11

Chap.10.1.1) as string type.

Test Command Syntax: AT+CXXCID=?

Response: OK

Exec Command Syntax: AT+CXXCID

Response: +CXXCID: <cid>

OK

ERROR

+CME ERROR: <err>

Note: See also: AT^SCID.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 197

Chapter 15 – SIM Application Toolkit (SAT) Commands

Chapter 15. SIM Application Toolkit

(SAT) Commands

This chapter offers a brief reference of commands and responses related to the Multi-Tech wireless modem’s SIM

Application Toolkit (SAT) implementation.

ETSI specification GSM 11.14 defines SAT in detail. SAT allows for the execution of applications provided by a

Subsciber Identity Module (SIM). Usually, SIM cards are used for storing GSM network provider and user specific data; e.g., phonebook entries and Short Messages (SMS). However, a SIM card may also hold a SIM Application.

Since the Multi-Tech wireless modem has SAT functionality, it is able to execute the commands issued by applications implemented on a network provider specific SIM card.

Two groups of commands are used between the ME and the SIM Application:

• Proactive Commands are issued to the Multi-Tech wireless modem’s SAT from the SIM Application, such as

“DISPLAY TEXT”.

• Envelope Commands are responded to the SIM Application from the Multi-Tech wireless modem, such as

“MENU SELECTION”.

15.1 AT^SSTA SAT Interface Activation

Description: SAT commands that are not using the AT interface (non MMI related SAT commands; e.g., PROVIDE LOCAL INFORMATION) can be executed without activating Remote-SAT.

The read command requests the current operating status and the used alphabet of the

Remote-SAT interface.

write command activates the AT command interface of the SIM Application Toolkit in the Multi-Tech wireless modem and needs to be issued after every power on. However, removing and inserting the SIM does not affect the activation status.

Test Command Syntax: AT^SSTA=?

Response: ^SSTA:(list of supported <state>s), (list of supported <Alphabet>s)

OK

Read Command Syntax: AT^SSTA?

Response: ^SSTA: <state>, <Alphabet>, <allowedInstance>, <SatProfile>

OK

Write Command Syntax: AT^SSTA=<mode>[, <Alphabet>]

Response: OK

Parameter Descriptions:

<state>

The Multi-Tech wireless modem Remote-SAT interface states.

0

1

2

3

4

<Alphabet>

0

RESET

OFF

IDLE

PAC

WAIT

GSM character set. Input of a character requests one byte; e.g., “Y”.

1 UCS2. To display the 16 bit value of characters represented in UCS2 alphabet a 4 byte string is required; e.g., “0059” is coding the character “Y”. For details please refer to

ISO/IEC 10646.

<allowedInstance>

0

1

<SatProfile>

SAT is already used on another instance (logical channel in case of the multiplex protocol). Only test and read commands can be used.

SAT profile according to GSM 11.14. The profile tells the SIM Application which features (e.g., proactive commands) are supported by the SIM Application Toolkit implementation of the Multi-Tech wireless modem.

<mode>

1

SAT may be started on this instance via the write version of this command.

Activate Remote-SAT

Note: To limit the time Remote-SAT is kept in states PAC or WAIT any ongoing (but unanswered) Proactive

Command is automatically aborted after 10 minutes with Terminal Response “ME currently unable to process command” or “No response from user” if applicable. An URC “Terminate Proactive Command” will be send to the external application in this case, too.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 198

Chapter 15 – SIM Application Toolkit (SAT) Commands

15.2 ^SSTN SAT Notification

Unsolicited Result Codes:

URC 1

Proactive Command notification

^SSTN: <cmdType>

Every time the SIM Application issues a Proactive Command, via the ME, the TA will receive a notification.

This indicates the type of Proactive Command issued.

AT^SSTGI must then be used by the TA to request the parameters of the Proactive Command from the ME.

Upon receiving the ^SSTGI response from the ME, the TA must send AT^SSTR to confirm the execution of the

Proactive Command and provide any required user response; e.g., a selected menu item.

URC 2

Terminate Proactive Command notification

^SSTN: <cmdTerminateValue>

When the SIM application has issued a Proactive Command to the ME, it is possible that this command will be terminated later. URC “^SSTN” is sent with a different Proactive Command type number (added terminate offset

100) to indicate the termination of the specified command.

The state changes to idle. Therefore, the TA should avoid sending any further commands related to the terminated Proactive Command; e.g., AT^SSTGI or AT^SSTR.

URC 3

Notification that SIM Application has returned to main menu

^SSTN: 254

Notification to the TA when the SIM Application has finished a command cycle and again enters its main menu, which was transferred with an URC “^SSTN: 37” (SET UP MENU) at start up.

This URC should be used to open this menu on the screen.

The TA does not need to respond directly; i.e., AT^SSTR is not required.

URC 4

SIM reset notification

^SSTN: 255

Notification to the TA if a Proactive Command “REFRESH - SIM Reset” has been issued by the SIM Application, please refer to AT^SSTGI.

This URC should be used to set the TAs application to its initial state since the SIM Application will start from the beginning, too.

The TA does not need to respond directly; i.e., related AT^SSTGI and AT^SSTR are neither required nor allowed.

Since the ME is still busy on SIM access the ME may respond with “+CME ERROR: SIM blocked” or “+CME

ERROR: SIM busy” on following PIN required AT Commands for a while. Then TA shall retry until the ME responds with “OK”. The time needed for this process depends on the SIM and may take more than 10 seconds.

Parameter Description:

<cmdType>

Proactive Command number

<cmdTerminateValue>

Defined as <cmdType> + terminate offset. The terminate offset equals 100.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 199

Chapter 15 – SIM Application Toolkit (SAT) Commands

15.3 AT^SSTGI SAT Get Information

Description: This command is used upon receipt of an URC “^SSTN” to request the parameters of the

Proactive Command. Then the TA is expected to acknowledge the AT^SSTGI response with AT^SSTR to confirm that the Proactive Command has been executed. AT^SSTR will also provide any user information; e.g., a selected menu item.

The Proactive Command type value specifies to which “^SSTN” the command is related.

Test Command Syntax: AT^SSTGI=?

Response: ^SSTGI:(list of supported <state>s), (list of supported <cmdType>s)

OK

Read Command Syntax: AT^SSTGI?

Response: ^SSTGI: <state> , <cmdType>

OK

Write Command Syntax: AT^SSTGI=<cmdType>

Response: OK

Parameter Descriptions:

<state>

The Multi-Tech wireless modem Remote-SAT interface states

0

1

2

3

4

<cmdType>

RESET

OFF

IDLE

PAC

WAIT

Related Proactive Command

15.4 AT^SSTR SAT Response

Description: The TA is expected to acknowledge the AT^SSTGI response with AT^SSTR to confirm that the Proactive Command has been executed. AT^SSTR will also provide any user information; e.g., a selected menu item.

Test Command Syntax: AT^SSTR=?

Response: ^SSTR:(list of supported <state>s), (list of supported <cmdType>s)

OK

Read Command Syntax: AT^SSTR?

Response: ^SSTR: <state>, <cmdType>

OK

Write Command Syntax: AT^SSTR=<cmdType>, <status>[, <inputNumber>][, <inputString>]

Response: OK

Parameter Description:

<state>

1

2

3

4

The Multi-Tech wireless modem Remote-SAT interface states

0 RESET

OFF

IDLE

PAC

WAIT

<cmdType>

Number related to Proactive Command or event type according to GSM 11.14.

<status>

Command status return regarding the type of action that has taken place; e.g., action performed by the user.

Values are in accordance with GSM 11.14.

<inputNumber>

Response number entered by user.

<inputString>

Response string entered by user.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 200

Chapter 17 – Audio Commands

Chapter 16. Phonebook Commands

The AT commands described in this chapter allow the external application to access the phonebooks located in the

Multi-Tech wireless modem’s memory or on the attached Subscriber Identity Module (SIM).

16.1 Sort Order for Phonebooks

Due to the support of UCS2 for the <text> part of phonebook entries, the sort order for phonebook records follows the algorithm published as Unicode Technical Standard #10, “Unicode Collation Algorithm”.

A memory-optimized version of the proposed collation tables “[AllKeys]” from Unicode Technical Standard #10 is used in order to determine collation weights for Code points between 0000 and 06FF, and composed keys are used for Code points from ranges 0700 to 33FF, A000 to D7FF and E000 to FFFD. Code Points not referenced in these tables will be assigned a default collation weight with their unicode value as level 1 weight. Decomposition is not supported.

Phonebook entries whose names contain only characters from the GSM07.07 default alphabet are converted internally into their UCS2 equivalents in order to achieve consistent sorting results.

For the user, this means that:

• Punctuation marks and other non-alphabetical characters from the common latin-based character sets, and from the standard GSM character set, will be sorted before any alphabetical characters. The ordering in which these marks appear as compared to other non-alphabetical characters from the same group is determined by their collation weights and does not reflect their code values in the UCS2 or GSM alphabet tables above.

Please refer to www.unicode.org

for detail.

• Alphabetical characters from the common latin-based character sets, and from the standard GSM character set, will be sorted according to their underlying base characters, plus the collation weights of their accent signs.

• Only collation levels 1 and 2 are regarded, so sorting is not case-sensitive.

Example: the European letters “Å” (GSM 0EH, UCS2 00C5h), “æ” (GSM 1DH, UCS2 00E6h), “ç” (GSM09h,

UCS2 00E7h), “a” (GSM 61H, UCS2 0061h ) and “b” (GSM 62H, UCS2 0062h) will be sorted in order “a”, “Å”,

“æ” “b”,”ç” although their numerical values in GSM and UCS2 suggest a different ordering.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 201

Chapter 17 – Audio Commands

16.2 AT+CNUM Read Own Numbers

Description: AT+CNUM returns the subscribers own number(s) from the SIM.

Test Command Syntax: AT+CNUM=?

Response(s): OK

Exec Command Syntax: AT+CNUM

Response(s): [+CNUM: [<alpha>], <number>, <type>]

[+CNUM: ... ]

OK

ERROR

+CME ERROR: <err>

Parameter Descriptions:

<alpha>

Optional alphanumeric string associated with <number>.

<number>

Phone number in format specified by <type>.

<type>

Type of address octet, see also: AT+CPBR <type>.

Note:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

16.3 AT+CPBR Read from Phonebook

Description: AT+CPBR serves to read one or more entries from the phonebook selected with

AT+CPBS.

test command returns the location range supported by the current phonebook storage, the maximum length of <number> field and the maximum length of <text> field.

Length information may not be available while SIM storage is selected. If storage does not offer format information, the format list contains empty parenthesizes. a location range from <location1> to <location2>. Hence, if no <location2> is given only the entry at <location1> will be displayed. If no entries are found at the selected location

“OK” will be returned.

Test Command Syntax: AT+CPBR=?

Response: +CPBR: (1-<maxloc>), <nlength>, <tlength>

OK

ERROR

Write Command Syntax: AT+CPBR=<location1>[, <location2>]

Response: [+CPBR: <location1>, <number>, <type>, <text>]

[+CPBR: <location2>, <number>, <type>, <text>]

OK

ERROR

Parameter Description:

<location1>

The first (lowest) location number within phonebook memory where to start reading. The maximum range supported by the current phonebook is given in the test command response.

If <location1> exceeds the upper bound <maxloc> (as indicated by the test command), command will respond with “+CME ERROR: invalid index”.

<location2>

The last (highest) location number within phonebook memory where to stop reading. The maximum range supported by the current phonebook is given in the test command response.

If both <location1> and <location2> are in the range indicated by the test command parameter <maxloc> the list of entries will be output and terminated with “OK”.

If <location2> exceeds the range indicated by the test command parameter <maxloc>, the list of entries will be output but terminated with “+CME ERROR: invalid index”.

<number>

Phone number in format specified by <type>, it may be an empty string.

<type>

Type of address octet, which defines the used type of number (ton) and the numbering plan identification (npi).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 202

Chapter 17 – Audio Commands

Please consider that for types other than 129 or 145 dialing from phonebook with ATD><mem><n> is, depending on the network, not always possible (refer to GSM 04.08 subclause 10.5.4.7 for details). See also <type> of

AT+CPBW.

Supported values are:

145

161

209

Dialing string <number> includes international access code character ‘+’

National number. Network support of this type is optional.

Dialing string <number> has been saved as ASCII string and includes non-digit characters other than “*”, “#” or “+”. Note that phonebook entries saved with this type cannot be dialed.

255 Dialing string <number> is a command to control a Supplementary Service; i.e., “*”, “#” codes are contained. Network support of this type is optional.

129 Otherwise

<text>

Text assigned to a phone number. The maximum length for this parameter is given with test command response parameter <tlength>. If using an ASCII terminal characters which are coded differently in ASCII and GSM have to be entered via escape sequences as described in Section 1.5, Supported character sets.

<maxloc>

Maximum location number for the currently selected storage. For phonebooks located on the SIM this value depends on the SIM card type.

<nlength>

Maximum length of phone number for “normal” locations. Depending on the storage a limited number of locations with extended memory is available per phonebook. These locations allow storing numbers with twice the standard length, which is 2*<nlength> digits for normal numbers, but only <nlength> digits for numbers saved with <type>=209.

<tlength>

Maximum length of <text> assigned to the telephone number. The value indicated by the test command is given in octets. If <text> is given as GSM characters each character corresponds to one octet. If the <text> string is given in UCS2, the maximum number of characters depends on the coding scheme used for the alpha field of the SIM according to GSM 11.11, Annex B. In the worst case the number of UCS2 characters is at least one less than half the number of GSM characters.

Note: Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned. See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Example:

AT+CPBR=?

+CPBR:(1-100),20,17

AT+CPBR =1,3

First run the AT+CPBR test command to find out the maximum range of entries stored in the active phonebook.

The Multi-Tech wireless modem returns the supported values, where 100 is the supported range of location numbers, 20 is the length of the phone number and 17 is the maximum length of the associated text.

Then use the AT+CPBR write command to display the phonebook entries sorted by location numbers. +CPBR:1,”+999999”,145,”Charlie”

+CPBR:2,”+777777”,145,”Bill”

+CPBR:3,”+888888”,145,”Arthur”

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 203

Chapter 17 – Audio Commands

16.4 AT+CPBS Select Phonebook Memory Storage

Description: AT+CPBS selects the active phonebook storage; i.e., the phonebook storage that all subsequent phonebook commands will be operating on.

read command returns the currently selected <storage>, the number of <used> entries and the <total> number of entries available for this storage.

Test Command Syntax: AT+CPBS=?

Response: +CPBS: (list of supported <storage>s)

OK

Read Command Syntax: AT+CPBS?

Response: +CPBS: <storage>, <used>, <total>

OK

Write Command Syntax: AT+CPBS=<storage>

Response: OK

+CME

Parameter Descriptions:

<storage>(str)

“FD“

“SM“

“ON“

Fixed Dialing Phonebook

Capacity: depends on SIM card; Location: SIM

SIM Phonebook. Default.

Capacity: depends on SIM card; Location: SIM

MSISDN List

Capacity: depends on SIM card; Location: SIM

“ME“

“LD“

“MC“

“RC“

Mobile Equipment Phonebook

Capacity: max. 250 entries; Location: ME

Last Number Dialed Phonebook

Stores all voice call numbers dialed with ATD, but no data call numbers.

AT+CPBW command is not applicable to this storage.

The LD list can be deleted with AT^SDLD or with AT^SPBD.

Capacity: max. 10 entries; Location: depends on SIM; this phonebook may reside partly or completely in ME

Missed (unanswered received) Calls List

AT+CPBW command is not applicable to this storage.

The MC list can be deleted with AT^SPBD.

Capacity: max. 10 entries; Location: ME

Received Calls List

AT+CPBW command is not applicable to this storage.

The RC list can be deleted with AT^SPBD.

Capacity: max. 10 entries; Location: ME

<used>

Value indicating the number of used locations in selected memory storage.

<total>

Value indicating the maximum number of locations allowed in the selected memory storage.

Notes:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

• If the SIM card is changed, all records of the “MC”, “RC” and “LD” phonebooks stored on the ME will be deleted automatically. If the same SIM is removed and reinserted, no automatic deletion is performed. Calls made after last switch-on will be lost from “MC”, “RC” and “LD” phonebook, if the SIM is removed and reinserted during normal operation.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 204

Chapter 17 – Audio Commands

16.5 AT+CPBW Write into Phonebook

Description: The AT+CPBW write command can be used to create, edit and delete a phonebook entry at a <location> of the active storage selected with AT+CPBS.

If <storage>=”FD” (SIM fixed dialing numbers) is selected, PIN2 authentication has to be performed prior to any write access.

test command returns the location range supported by the current storage, the maximum length of the <number> field, the range of supported <type> values and the maximum length of the <text> field.

The length may not be available while SIM storage is selected. If storage does not offer format information, the format list contains empty parenthesizes.

Test Command Syntax: AT+CPBW=?

Response: +CPBW: (1-<maxloc>), <nlength>, (list of supported <type>s), <tlength>

OK

ERROR

ERROR

Write Command Syntax: AT+CPBW=[<location>][, <number>[[, <type>][, <text>]]]

Response: OK

ERROR

ERROR

Parameter Description:

<location>

Location number within phonebook memory. The maximum range supported by each storage type is indicated in the test command response. If <location> is not given, the first free entry will be used.

If <location> is given as the only parameter, the phonebook entry specified by <location> is deleted.

<number>

Phone number in format specified by <type>. Parameter must be present, although it may be an empty string.

Alphabetic characters are not permitted. <number> may contain dialstring modifiers “*”, “#” or “+”.

If other printable non-alphabetic characters are used the entry needs to be saved with <type>=209. Otherwise, if

<type>=209 is not used any non-digit characters other than “*”, “#” or “+” will be removed from the string and only accepted modifiers from the GSM alphabet will be saved.

A <number> saved with <type>=209 requires double memory. In order to fit into a standard location, the number needs to be reduced to a maximum length of <nlength>/2, including all digits and dial string modifiers.

Extended locations may be used as stated below for <nlength>.

<type>

Type of address octet, which defines the used type of number (ton) and the numbering plan identification (npi).

Please consider that for types other than 129 or 145 dialing from phonebook with ATD><mem><n> is, depending on the network, not always possible (refer GSM 04.08 subclause 10.5.4.7 for details). Supported values are:

145

161

209

Dialing string <number> includes international access code character ‘+’

National number. The network support for this type is optional.

Dialing string <number> will be saved as ASCII string.

This is the default value, if <type> is not specified explicitly and characters other than “*”, “#” or

255

129

“+” are included in <number>.

Note that phonebook entries saved with this type cannot be dialed.

Dialing string <number> is a command to control a Supplementary Service; i.e., “*”, “#” codes are contained. Network support of this type is optional.

Otherwise

This is the default value, if <type> is not specified explicitly and characters other than “*”, “#” or

“+” are not included in <number>.

<text>

Text assigned to the phone number. The maximum length of this parameter is given in the test command response <tlength>. When using an ASCII terminal, characters which are coded differently in ASCII and GSM have to be entered via escape sequences as described in Section 1.5, Supported character sets.

<maxloc>

Maximum number of locations supported by the currently selected storage. For phonebooks located on SIM, this value varies depending on the SIM card. See AT+CPBS for typical values.

<nlength>

Maximum length of phone number for “normal” locations. Depending on the storage, a limited number of locations with extended memory is available per phonebook. These locations allow storing numbers with twice the standard length, which is 2*<nlength> digits for normal numbers, but only <nlength> digits for numbers saved with parameter <type>= 209. If all extended locations of the selected phonebook are used up, then any attempt to write a number which requires extended memory will be denied with CME ERROR 260: INVALID DIAL

STRING.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 205

Chapter 17 – Audio Commands

<tlength>

Maximum length of <text> assigned to the telephone number. The value indicated by the test command is given in octets. If the <text> string is given in GSM characters, each character corresponds to one octet. If the <text> string is given in UCS2, the maximum number of characters depends on the coding scheme used for the alpha field of the SIM. In the worst case the number of UCS2 characters is at least one less than half the number of

GSM characters.

For a detailed description please refer to GSM 11.11, Annex B.

Note:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Examples

Example 1 – Make a new phonebook entry at the first free location

AT+CPBW=,”+431234567”,145,”international”

Example 2 – Delete entry at location 1

AT+CPBW=1

Example 3 – The following examples are provided to illustrate the effect of writing phonebook entries with different types of dial string modifiers in <number>

AT+CPBW=5,”12345678”,,”Arthur”

AT+CPBW=6,”432!+-765()&54*654#”,,”John”

AT+CPBW=7,”432!+-765()&54*654#”,129,”Eve”

AT+CPBW=8,”432!+-765()&54*654#”,145,”Tom”

AT+CPBW=9,”432!+-765()&54*654#”,209,”Richard”

Example 4 – Read phonebook entries from locations 5 - 9 via AT+CPBR

+CPBR:5,”12345678”,129,”Arthur”

+CPBR:6,”432!+-765()&54*654#”,209,”John”

+CPBR:7,”432+76554*654#”,129,”Eve”

+CPBR:8,”+432+76554*654#”,145,”Tom”

+CPBR:9,”432!+-765()&54*654#”,209,”Richard”

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 206

Chapter 17 – Audio Commands

16.6 AT^SDLD Delete the ‘Last Number Redial

Memory

Description: AT^SDLD deletes all numbers stored in the “LD” memory.

Test Command Syntax: AT^SDLD=?

Response: OK

Exec Command Syntax: AT^SDLD

Response: OK

ERROR

+CME ERROR: <err>

Note:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

16.7 AT^SPBC Find First Matching Entry in Sorted

Phonebook

Description: The

(lowest) entry that matches the character specified with <schar>. The AT^SPBC test command returns the list of phonebooks which can be searched through with AT^SPBC.

Please note that AT^SPBC is assigned the same index as AT^SPBG or

AT^SPBS which is not identical with the physical location numbers used in the various phonebooks. Therefore, do not use the index numbers retrieved with AT^SPBC to dial out or modify phonebook entries.

Test Command Syntax: AT^SPBC=?

Response: ^SPBC: “FD”,”SM”,”ME”

OK

ERROR

ERROR

Write Command Syntax: AT^SPBC=<schar>

Response: ^spbc: <index>

OK

ERROR

ERROR

Parameter Description:

<schar>

First character of the entry to be searched in the sorted list of phonebook entries.

<index>

In the active phonebook, the first (lowest) index number of an entry beginning with <schar>. As stated above, the retrieved index number shall not be used to dial out or edit phonebook entries. If no matching phonebook entry is found, <index>=0 will be returned.

Note:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 207

Chapter 17 – Audio Commands

16.8 AT^SPBD Purge Phonebook Memory Storage

Description: AT^SPBD can be used to purge the selected phonebook <storage> manually; i.e., all entries stored in the selected phonebook storage will be deleted.

CAUTION! The operation cannot be stopped nor reversed!

AT^SPBD

AT^SPBD. card. This affects the ME based part of the “LD” storage, and storages “MC” and “RC”.

Storage “ME” is not affected.

Test Command Syntax: AT^SPBD=?

Response: ^SPBD: list of supported <storage>s

OK

Write Command Syntax: AT^SPBD=<storage>

Response: OK

+CME

Parameter Description:

<storage>

If test command: List of phonebooks which can be deleted by AT^SPBD.

If write command: Phonebook to be deleted.

For a detailed description of storages see AT+CPBS.

“LD“

“MC“

“RC“

Last number dialed phonebook

Missed (unanswered received) calls list

Received calls list

Note:

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 208

Chapter 17 – Audio Commands

16.9 AT^SPBG Display Phonebook Entries in

Alphabetical Order

Description: AT^SPBG sorts the entries of the current phonebook in alphabetical order by name (the first six characters matter). The sort order is described in Section 16.1, Sort Order for Phonebooks.

There are two ways to use AT^SPBG:

• If the optional parameter <RealLocReq> equals 0 or is omitted, the sorted entries will be sequentially numbered. As these numbers are not identical with the location numbers stored in the various phonebooks, AT^SPBG can be used for reading only. For example, it helps you find entries starting with matching characters. Do not use the serial numbers to dial out or modify entries.

• If parameter <RealLocReq>=1 is given by the write command, the response parameter

<location> additionally appended to each entry indicates the actual location number. This number can be used for editing with AT+CPBW or dialing with ATD><mem><n>. The first index number of each entry is only the serial number of the sorted list.

Before using the write command, it is recommended to query the number of records currently stored in the active phonebook (refer to test command <used>). The test command also includes the <nlength> and <tlength>. Note that if SIM storage is selected, the length may not be available. If storage does not offer format information, the format list shows empty parentheses.

Test Command Syntax: AT^SPBG=?

Response: ^SPBG: (1-<used>), <nlength>, <tlength>

OK

ERROR

ERROR

Write Command Syntax: AT^SPBG=<index1>[, <index2>][, <RealLocReq>]

Response: [^SPBG: <index1>, <number>, <type>, <text>[, <location>]]

[^SPBG: <index2>, <number>, <type>, <text>[, <location>]]

OK

ERROR

ERROR

Parameter Description:

<index1>

First index number in the sorted list where reading starts. See the test command response for supported range.

If <index 1> exceeds the upper bound <used>, “+CME ERROR: “invalid index” will be returned.

<index2>

Last index number in the sorted list where to stop reading. See the test command response for supported range.

If <index2> is not given via write command, only the entry located at <index1> will be displayed.

If both <index1> and <index2> are in the range indicated by the test command parameter <used>, the list of entries will be output and terminated with OK.

If <index2> exceeds the range indicated by the test command parameter <used>, the list of entries will be output but terminated with a “+CME ERROR: “invalid index”.

<RealLocReq>

Is a display of the “real” <location> of the entry required?

0 Do not show an entry’s “real” location number. Parameter <location> will not be displayed. Default.

1 Show the “real” location number as parameter <location> at the end of each entry.

<number>

String type phone number in format specified by <type>.

The number parameter may be an empty string.

<type>

Type of address octet that defines the type of number (ton) and the numbering plan identification (npi) used.

Please consider that for types other than 129 or 145 dialing from phonebook with ATD><mem><n> is, depending on the network, not always possible (refer to GSM 04.08 subclause 10.5.4.7 for details). See AT+CPBW <type>.

Possible values are:

145

161

209

255

129

Dialing string <number> includes international access code character ‘+’

National number. Network support of this type is optional.

Dialing string <number> has been saved as ASCII string and includes non-digit characters other than “*”, “#” or “+”. Note that phonebook entries saved with this type cannot be dialed.

Dialing string <number> is a command to control a Supplementary Service; i.e., “*”, “#” codes are contained. Network support of this type is optional.

Otherwise

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 209

Chapter 17 – Audio Commands

<text>

Text assigned to the phone number. The maximum length for this parameter is given in test command response

<tlength>.

<used>

Value indicating the number of used locations in selected memory storage.

<location>

The location within phonebook memory at which the corresponding entry is located.

This location may be used for other commands (e.g., AT+CPBR or ATD><mem><n>)

<nlength>

Maximum length of phone number for “normal” locations. Depending on the storage, a limited number of locations with extended memory is available per phonebook. Please refer to AT command AT+CPBW for detail.

<tlength>

Maximum length of <text> assigned to the telephone number. The value indicated by the test command is given in octets. If the <text> string is given in GSM characters, each character corresponds to one octet. If the <text> string is given in UCS2, the maximum number of characters depends on the coding scheme used for the alpha field of the SIM according to GSM 11.11, Annex B. In the worst case the number of UCS2 characters is at least one less than half the number of GSM characters.

Notes:

• The command can be used for the phonebooks “SM”, “FD”, “ME” (cf. AT+CPBS).

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Examples:

Example 1 – Using AT^SPBG without <RealLocReq>:

The numbers at the beginning of each line are not the memory locations in the phonebook, but only serial numbers assigned to the entries’ positions in the alphabetical list.

AT^SPBG=?

^SPBG: (1-33),20,17

AT^SPBG=1,33

First run the AT^SPBG test command to find out the range of entries stored in the current phonebook.

TA returns the range, where 33 is the number of entries stored in the current phonebook.

Now, enter the write command. To obtain best results it is recommended to query the full range of entries. TA returns phonebook entries in alphabetical order.

^SPBG:1,”+999999”,145,”Arthur”

^SPBG:2,”+777777”,145,”Bill”

^SPBG:3,”+888888”,145,”Charlie”

......................

Example 2 – Using AT^SPBG with <RealLocReq>:

AT^SPBG=?

^SPBG: (1-33),20,17

AT^SPBG=1,33,1

First run the AT^SPBG test command to find out the range of entries stored in the current phonebook.

TA returns the range, where 33 is the number of entries stored in the current phonebook.

Now, enter the write command including parameter

<RealLocReq>=1 to get the actual location numbers.

^SPBG:1,”+999999”,145,”Arthur”,27

^SPBG:2,”+777777”,145,”Bill”,6

^SPBG:3,”+888888”,145,”Charlie”,15

......................

The numbers at the end of each line are the memory locations in the phonebook and can be used for dialing or editing phonebook entries:

AT+CPBR=27

+CPBR: 27,”+999999”,145,”Arthur”

Read out phonebook location 27.

This entry can be edited with AT+CPBW or used for dialing with

ATD><mem><n>.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 210

Chapter 17 – Audio Commands

16.10 AT^SPBS Step Through the Selected

Phonebook Alphabetically

Description: AT^SPBS can be used to scroll sequentially through the active phonebook records in alphabetical order by name. Three entries will be displayed at a time.

Every time the write command is executed, 3 rows of phonebook records are returned. Each triplet overlaps with the next one. The actual index depends on parameter <value>. This parameter determines whether the index will be increased or decreased. If the index in one output line reaches the last index in the alphabetical list, the next output line will display the first list entry. After the last record of the phonebook has been reached (see parameter AT^SPBG

<used>), the <internal-counter> switches over to the first.

There are two ways to use AT^SPBS:

• If the optional parameter <RealLocReq> is omitted or (0) the sorted entries will be sequentially numbered. As these numbers are not identical with the location numbers stored in the various phonebooks AT^SPBS can be used for reading only. For example, it helps you find entries starting with matching characters. Do not use the serial numbers to dial out or modify entries.

• If parameter <RealLocReq>=1 is given by the write command, the response parameter

<location> additionally appended to each entry indicates the actual location number. This number can be used for editing with AT+CPBW or dialing with ATD><mem><n>. The first index number of each entry is only the serial number of the sorted list.

Test Command Syntax: AT^SPBS=?

Response: ^SPBS: (list of supported <value>)

OK

Write Command Syntax: AT^SPBS=<value>[, <RealLocReq>]

Response: ^SPBS: <index-a>, <number>, <type>, <text>[, <location>]

^SPBS: <index-b>, <number>, <type>, <text>[, <location>]

^SPBS: <index-c>, <number>, <type>, <text>[, <location>]

OK

Parameter Description:

<value>

1

2

To make a step forward in the alphabetically sorted phonebook.

To make a step backward in the alphabetically sorted phonebook.

<index-a>

1...maxindex The index in the sorted list of phonebook entries that identifies the first entry displayed.

The value of <index-a> is determined by the value of the <internalcounter> and by <value>.

After a write command has terminated successfully with “OK”, the value from <index-a> is saved and retained as the new <internalcounter> value.

After the last record of phonebook, the first entry follows.

<index-b>

1...maxindex The index in the sorted list of phonebook entries that identifies the second entry displayed.

<index-b>= (<index-a>+1).

After the last record of phonebook, the first entry follows.

<index-c>

1...maxindex The index in the sorted list of phonebook entries that identifies the third entry displayed.

<index-c>= (<index-b>+1).

After the last record of phonebook, the first entry follows.

<number>

String type phone number in format specified by <type>.

The number parameter may be an empty string.

<type>

Type of address octet that defines the type of number (ton) and the numbering plan identification (npi) used.

Please consider that for types other than 129 or 145 dialing from phonebook with ATD><mem><n> is, depending on the network, not always possible (refer to GSM 04.08 subclause 10.5.4.7 for details). See <type> of

AT+CPBW. Possible values are:

145

161

209

255

Dialing string <number> includes international access code character ‘+’

National number. Network support of this type is optional.

Dialing string <number> has been saved as ASCII string and includes non-digit characters other than “*”, “#” or “+”. Note that phonebook entries saved with this type cannot be dialed.

Dialing string <number> is a command to control a Supplementary Service; i.e., “*”, “#” codes are

129 contained. Network support of this type is optional.

Otherwise

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 211

Chapter 17 – Audio Commands

<text>

Text assigned to the phone number.

<RealLocReq>

Is a display of the “real” <location> of the entry required?

0

1

Do not show an entry’s “real” location number. Parameter <location> will not be displayed.

Default.

Show the “real” location number as parameter <location> at the end of the entry

<location>

The location within the phonebook memory at which the corresponding entry is located.

This location may be used for other phonebook commands (e.g., AT+CPBR, AT+CPBW, ATD><mem><n>).

<internal-counter>

0...maxindex This parameter is only an internal parameter and cannot modified directly. Default = 0.

Notes:

The internal counter will be reset to index 0 after a call to ATZ or AT&F.

• The complete list of sorted entries can be retrieved using AT command AT^SPBG.

• The command can be used for the phonebooks “SM”, “FD”, “ME” (cf. AT+CPBS).

• Users should be aware that when using this AT command quickly after SIM PIN authentication, the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section 20.1, Restricted Access to SIM Data after SIM PIN Authentication.

Examples

Example 1 – This example illustrates how to search down and up again using AT^SPBS=1 and 2: at&f First, AT&F is issued to make sure that AT^SPBS=1 starts from the first character in alphabetical order.

OK at^spbs=1

^SPBS:1,”+999999”,145,”Arthur”

^SPBS:2,”+777777”,145,”Bill”

^SPBS:3,”+888888”,145,”Charlie”

OK at^spbs=1

^SPBS:2,”+777777”,145,”Bill”

^SPBS:3,”+888888”,145,”Charlie”

^SPBS:4,”0304444444”,129,”Esther”

OK at^spbs=1

^SPBS:3,”+888888”,145,”Charlie”

^SPBS:4,”0304444444”,129,”Esther”

^SPBS:5,”03033333333”,129,”Harry”

OK at^spbs=2

^SPBS:2,”+777777”,145,”Bill”

^SPBS:3,”+888888”,145,”Charlie”

^SPBS:4,”0304444444”,129,”Esther”

OK

Example 2 – This example shows that when the last index in the sorted list has been reached, the internal counter overflows to the first index.

Reset internal counter to 0. at&f

OK at^spbs=2

^SPBS:33,”+49301234567”,145,”TomTailor”

^SPBS:1,”+999999”,145,”Arthur”

^SPBS:2,”+777777”,145,”Bill”

Step down one entry starting from (internal counter)=0 - overflow occurs.

OK

Example 3 – Using AT^SPBS with <RealLocReq>=1 in order to obtain the entries’ location numbers: at^spbs=1,1

^SPBS:1,”+999999”,145,”Arthur”,27

^SPBS:2,”+777777”,145,”Bill”,6

^SPBS:3,”+888888”,145,”Charlie”,15

The numbers at the end of each line are the memory locations in the phonebook and can be used for dialing or editing phonebook entries: at+cpbr=27

+CPBR: 27,”+999999”,145,”Arthur”

ATD><mem><n>.

Read out phonebook location 27. his entry can be edited with AT+CPBW or used for dialing with

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 212

Chapter 17 – Audio Commands

Chapter 17. Audio Commands

The AT Commands described in this chapter are related to the Multi-Tech wireless modem’s audio interface.

17.1 Audio Programming Model

The following figure illustrates how the signal path can be adjusted with the parameters <inCalibrate>, <inBbcGain>,

<outBbcGain>, <outCalibrate> and <sideTone>.

Figure 17.1: Audio programming model

17.2 ATL Set Monitor Speaker Loudness

Description: ATL is implemented for V.250ter compatibility reasons only and has no effect. In multiplex mode refer to the AT+CMUX; the command is supported on logical channel 1 only.

Exec Command Syntax: ATL[<val>]

Response:

Parameter Description:

<val>

OK

17.3 ATM Set Monitor Speaker Mode

Description: ATL is implemented for V.250ter compatibility reasons only and has no effect. In multiplex mode refer to the AT+CMUX; the command is supported on logical channel 1 only.

Exec Command Syntax: ATM[<val>]

Response: OK

Parameter Description:

<val>

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 213

Chapter 17 – Audio Commands

17.4 AT+CLVL Loudspeaker Volume Level

Test Command Syntax: AT+CLVL=?

Response: +CLVL: (list of supported<level>s)

OK

Read Command Syntax: AT+CLVL?

Response: +CLVL: <level>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CLVL=<level>

Response:

ERROR

OK

+CME ERROR: <err>

Parameter Description:

<level>

Loudspeaker Volume Level

0...4 Default = 4

Notes:

• The write command can only be used in audio mode 2 - 6.

• The values of the volume steps are specified with the parameters <outCalibrate>[0],...<outCalibrate>[4] of the

AT^SNFO command.

• As an alternative to AT+CLVL, you can use AT^SNFO and AT^SNFV. The parameter <level> is identical with

<outStep> used by both commands.

• Any change to <level> (or <outStep>) takes effect in audio modes 2 to 6. That is, when you change <level> (or

<outStep>) and then select another mode with AT^SNFS, the same step will be applied.

The only exception is audio mode 1 which is fixed to <level>=4 (or accordingly <outStep>=4).

• <level> (or <outStep>) is stored non-volatile when the ME is powered down with AT^SMSO or reset with

AT+CFUN=1,1.

17.5 AT+CMUT Mute Control

Description: The AT+CMUT command mutes the microphone input. The command can be used in all audio modes (1 to 6) and during a voice call only. See AT^SNFS for more details on the various audio modes. As alternative, you can use the AT^SNFM command.

During an active call, users should be aware that when they switch back and forth between different audio modes (for example handsfree on/off) the value of <mute> does not change; i.e., the microphone mode is retained until explicitly changed.

Test Command Syntax: AT+CMUT=?

Response: +CMUT: (list of supported<mute>s)

OK

Read Command Syntax: AT+CMUT?

Response: +CMUT: <mute>

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CMUT=<mute>

Response: OK

ERROR

+CME ERROR: <err>

Parameter Description:

<mute>

0

1

Mute off. Default.

Mute on

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 214

Chapter 17 – Audio Commands

17.6 AT+VTD Tone Duration

Description: This command refers to an integer <duration> that defines the length of tones transmitted with the AT+VTS command.

Test Command Syntax: AT+VTD=?

Response: +VTD: (list of supported<duration>s)

OK

Read Command Syntax: AT+VTD?

Response: <duration>

OK

Write Command Syntax: AT+VTD=<duration>

Response: OK

Parameter Description:

<duration>

Duration of the tone in 1/10 second

1...255 Default = 1

17.7 AT+VTS DTMF and Tone Generation

Description: AT+VTS is intended to send ASCII characters or strings which cause the Mobile Switching

Center (MSC) to transmit DTMF tones to a remote subscriber. The command can only be used during active voice calls and offers the following variants:

• AT+VTS=<dtmfString> allows to send a sequence of DTMF tones with a duration defined with AT+VTD.

• AT+VTS=<dtmf>[,<duration>] allows to send a single DTMF tone. In this case, the duration can be indvidually determined during the call.

Test Command Syntax: AT+VTS=?

Response: +VTS: (list of supported<dtmf>s), (list of supported<duration>s)

OK

Write Command Syntax: AT+VTS=<dtmfString>

Response: OK

Write Command Syntax: AT+VTS=<dtmf>[, <duration>]

Response: OK

Parameter Description:

<dtmfString> String of ASCII characters in the set 0-9,#,*,A, B, C, D. Maximal length of the string is 29.

The string must be enclosed in quotation marks (“...”).

<dtmf> ASCII character in the set 0...9,#,*, A, B, C, D.

<duration> Tone duration in 1/10 second. If not specified current setting of AT+VTD is used.

1...255

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 215

Chapter 17 – Audio Commands

17.8 AT^SAIC Audio Interface Configuration

Description: AT^SAIC configures the interface connections of the active audio mode. The write

command is usable in audio modes 2 to 6 only.

If AT^SNFS=1, any attempt to use the AT^SAIC write command is rejected with and returns an error reponse. This is because all default parameters in audio mode 1 are determined for type approval and are not adjustable.

To allocate a specific audio mode to one of the audio interfaces, first select the audio mode with AT^SNFS and then choose the interface using AT^SAIC.

Note: Only audio interface 1 is supported.

Test Command Syntax: AT^SAIC=?

Response: ^SAIC:(list of supported <io>s), (list of supported<mic>s), (list of supported<ep>s)

OK

Read Command Syntax: AT^SAIC?

Response: ^SAIC: <io>, <mic>, <ep>

OK

Write Command Syntax: AT^SAIC=<io>[, <mic>[, <ep>]]

Response: OK

ERROR

+CME ERROR: operation not allowed

Parameter Description:

<io>

1

2

Input and output selection

Not available

Analog input and output

<mic> Microphone

1 Microphone 1

<ep>

1

Notes:

Select differential earpiece amplifier

Selects the earpiece amplifier 1

• The factory defaults of AT^SAIC vary with the selected audio mode.

If AT^SNFS=1 or 4 or 5, then AT^SAIC=2,1,1.

If AT^SNFS=2 or 3 or 6, then AT^SAIC=2,2,2.

AT^SNFD can be used to reset the factory defaults.

• For use after restart of the ME, you are advised to store the settings of AT^SAIC and AT^SNFS to the audio profile saved with AT^SNFW. Otherwise, audio mode 1 (AT^SNFS=1) and audio interface 2 (AT^SAIC=2,1,1) will be active each time the ME is powered up.

• Only audio interface 1 is supported. Always use AT^SAIC=1)

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 216

Chapter 17 – Audio Commands

17.9 AT^SNFA Set or Query of Microphone

Attenuation

Description: AT^SNFA specifies the large-scale attenuation on the microphone path of the audio device currently selected with AT^SNFS. The write command is only available in audio modes 2 to 6.

Test Command:

Response:

AT^SNFA=?

^SNFA: (list of supported <atten>s)

OK

Read Command:

Response:

AT^SNFA?

^SNFA: <atten>

OK

Write Command:

Response:

AT^SNFA=<atten>

OK

ERROR

CME ERROR: <err>

Parameter Description:

<atten>

Multiplication factor for input samples. Parameter <atten> is identical with <inCalibrate> of AT^SNFI.

Formula used to calculate microphone attenuation (negative gain):

Gain in dB = 20 * log(<atten>/32768)

0.....65535 Default = 32767

0

32767

Microphone is muted.

Please note that AT^SNFA cannot be used to mute the microphone. Therefore, any attempt to enter 0 will be rejected and an error response will be given. Value 0 is returned only by the read command AT^SNFA? after the microphone was muted with AT^SNFM=0 during an active call.

No attenuation on the microphone path.

Values greater than 32767 will be suppressed to 32767.

Notes:

• This command is provided for compatibility with former products and is a subset of AT^SNFI. The parameter

<inCalibrate> of AT^SNFI is identical with <atten> of AT^SNFA.

• To make the changes persistent use AT^SNFW.

Example:

^SYSSTART at^snfa=?

^SNFA: (0-65535)

OK at^snfa?

^SNFA: 32767

OK at^snfs=4

OK at^snfa=1

OK at^snfa?

^SNFA: 1

OK at^snfi?

^SNFI: 5,1

OK at^snfi=5,45

OK at^snfa?

^SNFA: 45

OK

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 217

Chapter 17 – Audio Commands

17.10 AT^SNFD Set Audio Parameters to

Manufacturer Default Values

Description: AT^SNFD sets the active audio parameters to manufacturer defined default values.

The restored values are:

<atten>

<inBbcGain>, <inCalibrate>

AT^SNFO: <outBbcGain>, <outCalibrate>[0 to 4], <sideTone>

AT^SAIC: <io>, <mic>, <ep>

Test Command Syntax: AT^SNFD=?

Response: OK

Exec Command Syntax: AT^SNFD

Response: OK

Note:

Remember that the factory set audio mode 1 is fixed to <outStep>=4. Consequently, AT^SNFD restores

<audMode> together with <outStep>=4, but does not affect the values of <outStep> currently selected in audio modes 2 - 6. This means, if <audMode>=1, the read commands AT^SNFO, AT^SNFV and AT+CLVL will always deliver <outStep>=4. In all other modes the <outStep> value is retained until explicitly changed.

17.11 AT^SNFI Set Microphone Path Parameters

Description: AT^SNFI controls the microphone path amplification. Read and write options of this command refer to the active audio mode. The write command works only in audio modes

2 to 6.

Test Command Syntax: AT^SNFI=?

Response: ^SNFI: (list of supported <inBbcGain>s) , (list of supported <inCalibrate>s)

OK

Read Command Syntax: AT^SNFI?

Response: ^SNFI: <inBbcGain>, <inCalibrate>

OK

Write Command Syntax: AT^SNFI=<inBbcGain>, <inCalibrate>

Response: OK

Parameter Descriptions:

<inBbcGain>

ADC gain adjustable in eight 6 dB steps from 0 dB to 42 dB (0=0dB, 7=42dB, 8 steps of 6 dB).

0...7

<inCalibrate>

Multiplication factor for input samples. Formula to calculate the negative gain (attenuation) of the input signal:

Gain in dB = 20 * log (inCalibrate / 32768)

0...32767

Notes:

• The range of <inCalibrate> is up to 65535 but will be suppressed to 32767. Values above <inCalibrate>=

65535 will cause a failure.

• The parameter <inCalibrate> of AT^SNFI is identical with <atten> of AT^SNFA.

• For use after restart, changed values can be stored with AT^SNFW.

• Attention! When you adjust audio parameters avoid exceeding the maximum allowed level. Bear in mind that exposure to excessive levels of noise can cause physical damage to users!

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 218

Chapter 17 – Audio Commands

17.12 AT^SNFM Set Microphone Audio Path

Description: The

write command can be used to switch the microphone’s audio path (muted/ not muted) .

The microphone can be muted or activated by changing <MicSwitch> in all audio modes

(1 to 6) and during a voice call only. As an alternative, you can use the AT+CMUT command to mute the microphone.

Test Command Syntax: AT^SNFM=?

Response: ^SNFM: (list of supported <MicSwitch>s)

OK

Read Command Syntax: AT^SNFM?

Response: ^SNFM: <MicSwitch>

OK

Write Command Syntax: AT^SNFM=[<MicSwitch>]

Response: OK

Parameter Description:

<MicSwitch>

Microphone mute control parameter.

Evaluated during voice calls and if <MicVccCtl> is omitted only (e.g., AT^SNFM=1).

Command does not depend on audio mode.

0

1

Mutes the microphone.

Activates the microphone. Default.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 219

Chapter 17 – Audio Commands

17.13 AT^SNFO Set Audio Output (= Loudspeaker

Path) Parameter

Description: AT^SNFO controls the earpiece path amplification. The read and write commands refer to the active audio mode.

Test Command Syntax: AT^SNFO=?

Response: ^SNFO: (list of supported <outBbcGain>s), (list of supported <outCalibrate>s), (list of supported <outStep>s), (list of supported <sideTone>s)

OK

Read Command Syntax: AT^SNFO?

Response: ^SNFO: <outBbcGain>, <outCalibrate>[0] , <outCalibrate>[1] , <outCalibrate>[2] ,

<outCalibrate>[3]

Write Command Syntax: AT^SNFO=<outBbcGain>, <outCalibrate>[0] , <outCalibrate>[1] , <outCalibrate>[2] ,

<outCalibrate>[3]

Response: OK

<outCalibrate>[4] , <outStep>, <sideTone>

OK

Parameter Descriptions:

<outBbcGain>

Negative DAC gain (attenuation) adjustable in four 6 dB steps from 0 dB to -18 dB (0=0 dB, 3=-18 dB)

0...3

<outCalibrate>

Formula to calculate the value of the 5 volume steps selectable with parameter <outStep>:

Attenuation = 20 * log (2 * outCalibrate[n] / 32768)

0...32767

<outStep>

Volume steps 0 - 4, each defined with outCalibrate[n]

0...[4]

<sideTone>

Multiplication factor for the sidetone gain.

Formula to calculate how much of the original microphone signal is added to the earpiece signal:

Sidetone gain in dB = 20 * log (sideTone / 32768).

0...32767

Notes:

• <outCalibrate> specifies the amount of volume of each <outStep>. The range of each <outCalibrate> is up to

65535, but will be suppressed to 32767. A value above <outCalibrate>= 65535 will cause an error.

• The range of <sideTone> is up to 65535, but will be suppressed to 32767. A value above <sideTone>=65535 will cause an error.

• Any change to <outStep> takes effect in audio modes 2 to 6. That is, when you change <outStep> and then select another mode with AT^SNFS, the same step will be applied. Nevertheless, the sound quality and the amount of volume are not necessarily the same, since all remaining audio parameters can use different values in either mode.

• Audio mode 1 is fixed to <outStep>=4. In this mode, any attempt to change <outStep> or other parameters returns an error.

• The value of <outStep> is stored non-volatile when the ME is powered down with AT^SMSO or reset with

AT+CFUN=x,1. Any other parameters changed with AT^SNFO need to be saved with AT^SNFW for use after restart. See also AT^SNFD for details on restoring factory defaults.

• The values of <outStep> can also be changed with AT^SNFV and AT+CLVL.

• CAUTION! When you adjust audio parameters avoid exceeding the maximum allowed level. Bear in mind that exposure to excessive levels of noise can cause physical damage to users!

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 220

Chapter 17 – Audio Commands

17.14 AT^SNFPT Set Progress Tones

Description: AT^SNFPT controls the Call Progress Tones generated at the beginning of a mobile originated call setup.

Please note that the setting is stored volatile; i.e., after restart or reset, the default value 1 will be restored.

Test Command Syntax: AT^SNFPT=?

Response: ^SNFPT: (list of supported <pt>s)

OK

Read Command Syntax: AT^SNFPT?

Response: ^SNFPT: <pt>

OK

Write Command Syntax: AT^SNFPT=<pt>

Response: OK

Parameter Description:

<pt>

0

1

Disables Call Progress Tones

Enables Call Progress Tones (audible tones shortly heard on the phone when ME starts to set up a call.) Default.

17.15 AT^SNFS Select Audio Hardware Set

Description: The

AT^SNFS is used with AT^SAIC. Each audio mode needs to be assigned to interface 1 via the AT^SAIC command. To do so, first select the audio mode with AT^SNFS, and then activate the audio interface with AT^SAIC and, finally, enter AT^SNFW to store the settings to your audio profile. To switch back and forth it is sufficient to use AT^SNFS.

Test Command Syntax: AT^SNFS=?

Response: ^SNFS: (list of supported <audMode>s)

OK

Read Command Syntax: AT^SNFS?

Response: ^SNFS: <audMode>

OK

Write Command Syntax: AT^SNFS=<audMode>

Response: OK

ERROR

CME ERROR: <err>

Parameter Description:

<audMode>

1 Audio mode 1: Standard mode optimized for the reference handset, that can be connected to the

2

3

4

5

6

Notes: analog interface 1. To adjust the volume use the knob of the reference handset. In audio mode 4, this handset can be used with user defined parameters. Default if no value is entered.

Note: The default parameters are determined for type approval and are not adjustable with AT commands.

AT^SNFD restores <audMode> 1.

Audio mode 2: Customer specific mode for a basic handsfree (speakerphone) device.

Audio mode 3: Customer specific mode for a mono-headset.

Audio mode 4: Customer specific mode for a user handset.

Audio mode 5: Customer specific mode.

Audio mode 6: Customer specific mode.

• The write command can be used during a voice call to switch back and forth between different modes. This allows the user, for example, to switch handsfree operation (speakerphone) on and off.

• <outStep> is a global setting. This means that when another audio mode is selected during a call, the value of

<outStep> does not change. This is also true for mute operation, which can be set with AT^SNFM or

AT+CMUT: If the microphone is muted and the user selects another audio mode during the call, then the microphone remains muted until explicitly changed. Exception: In audio mode 1 <outStep>=4 is fix.

• For use after restart of the module, you are advised to store the selected mode to the audio profile saved with

AT^SNFW. Otherwise, audio mode 1 will be active each time the module is powered up.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 221

Chapter 17 – Audio Commands

17.16 AT^SNFTTY Signal TTY/CTM Audio Mode

Capability

Description: The Multi-Tech wireless modem offers basic support for equipment using the CTM standard

(Cellular Text Telephone Modems). The benefit of CTM is that text characters typed on a TTY device (Text Telephone Type-writer) can be transformed into special audio burst signals for reliable transmission via the existing speech channels of a cellular phone system.

If CTM mode is activated, the ME will set the necessary bearer capability bit on outgoing (mobile originated) calls and incoming calls with this bearer capability bit set are accepted. The TE needs to decode the special audio burst signals.

If CTM mode is disabled, the ME will clear the bearer capability bit on mobile originated calls and incoming calls with the bearer capability bit set are rejected because the Multi-Tech wireless modem expects that CTM coded speech data cannot be decoded by the TE.

Designed to set the module’s speech system into CTM mode, the AT^SNFTTY command allows a CTM device to be connected to one of the three audio interfaces of the Multi-Tech wireless modem. Traditional TTY devices that do not incorporate CTM functionality can be connected through an external TTY-to-CTM adapter.

Related documents: Refer to the relevant standards, such as 3GPP TS 26.226 (ETSI TS 126

226) and 3GPP TS 23.228 (ETSI TS 123 226). 3GPP documentation can be retrieved, for example, from http://www.3gpp.org/specs/specs.htm. Application Note 22 “Using TTY/CTM equipment” supplies information needed to connect TTY/CTM equipment to the Multi-Tech wireless modem.

Requirements for using TTY/CTM features:

• TTY/CTM functionality requires audio mode 5 or 6 with all audio parameters set to their factory default.

To do so, first enter the AT^SNFS command to select audio mode 5, then use AT^SNFI and AT^SNFO to restore the default values. Alternatively, factory defaults of all audio parameters in audio modes 2 - 6 can easily be set with AT^SNFD.

• Depending on which audio interface the CTM device is connected to select the according settings via AT^SAIC.

Test Command Syntax: AT^SNFTTY=?

Response: ^SNFTTY: (list of supported <audioState>s)

OK

Read Command Syntax: AT^SNFTTY?

Response: ^SNFTTY: <audioState>

OK

Write Command Syntax: AT^SNFTTY=<audioState>

Response: OK

ERROR

+CME ERROR: <err>

Parameter Description:

<audioState>

0

1

Audio path is in normal speech mode.

Audio path is in TTY/CTM mode.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 222

Chapter 17 – Audio Commands

17.17 AT^SNFV Set Loudspeaker Volume

Description: AT^SNFV can be used to set the volume of the loudspeaker to the value <outCalibrate> addressed by <out-Step>. The read and write commands refer to the active audio mode.

The write command works only in audio modes 2 to 6.

Test Command Syntax: AT^SNFV=?

Response: ^SNFV: (list of supported <outStep>s)

OK

Read Command Syntax: AT^SNFV?

Response: ^SNFV: <outStep>

OK

Write Command Syntax: AT^SNFV=<outStep>

Response: OK

ERROR

Parameter Description:

<outStep>

The actual volume of each step is defined by the parameter <outCalibrate>, which can be set with AT^SNFO.

0...4 Default = 4.

Notes:

• Any change to <outStep> takes effect in audio modes 2 to 6. That is, when you change <outStep> and then select another mode with AT^SNFS, the same step will be applied. Nevertheless, the actual volume can be quite different, depending on the values of <outCalibrate> set in each mode. The only exception is audio mode

1 which is fixed to <outStep>=4.

• <outStep> is stored non-volatile when the ME is powered down with AT^SMSO or reset with AT+CFUN=1,1.

<outStep> is not stored by AT^SNFW.

• <outStep> can also be changed by AT^SNFO (Section 17.13) and AT+CLVL (Section 17.4).

17.18 AT^SNFW Write Audio Setting in Non-

Volatile Store

Description: AT^SNFW causes the TA to write the currently selected audio parameters to non-volatile store. The saved audio profile includes the following parameters:

AT^SNFA: <atten>

AT^SNFI: <inBbcGain>, <inCalibrate>

AT^SNFO: <outBbcGain>, <outCalibrate>[0 to 4], <sideTone>

AT^SNFS: <audMode>

AT^SAIC: <io>, <mic>, <ep>.

Test Command Syntax: AT^SNFW=?

Response: OK

Exec Command Syntax: AT^SNFW

Response: OK

ERROR

CME ERROR: <err>

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 223

Chapter 17 – Audio Commands

17.19 AT^SRTC Ring Tone Configuration

Description: The read command returns the current <type> and current <volume>. It can be used while test playback is off or on. In the latter case, see execute command for details.

AT^SRTC audio output currently selected with AT^SNFS. To deactivate test playback use AT^SRTC again.

During test playback, you can enter the write command to select another melody and adjust the volume. Also, you can enter the read command to check the type and volume of the current ring tone and to view the status of playback (on / off). The test ringing signal cannot be activated when an MTC is ringing (ERROR).

Selecting <volume>=0 during the test, immediately stops playback. After this, ring tones will be muted until you change <volume> using the write command. changed no matter whether or not the ME is ringing. The selected type and volume are saved in the non-volatile Flash memory and, thus, are retained after Power Down. An exception is

<type>=0, that can be entered to quickly mute the tone or melody currently played to indicate an event. <type>=0 only stops immediately the audible ring tone, but does not terminate the URC that indicates the event (for example RING). No permanent settings are changed or saved.

Test Command: AT^SRTC=?

Response: ^SRTC:(list of supported) <type>s, (list of supported) <volume>s

OK

Read Command: AT^SRTC?

Response: ^SRTC: <type>, <volume>, <status>

OK

Exec Command: AT^SRTC

Response: OK

Write Command: AT^SRTC=[<type>][, <volume>]

Response: ^SRTC: <type>, <volume>

OK

ERROR

Parameter Description:

<type>

Type of ring tone. You have a choice of 7 different ring tones and melodies. All will be played from the audio output selected with the AT^SNFS command. <type>=0 is only intended for muting.

0

1

2

3

4

5

6

7

Mutes the currently played tone immediately.

Sequence 1

Sequence 2

Sequence 3

Sequence 4

Sequence 5

Sequence 6

Sequence 7

<volume>

Volume of ring tone, varies from low to high

0 Mute

1

2

3

4

5

Very low

Identical with 1

6

7

Low

Identical with 3

Middle

Identical with 5

High

<status>

Status of test ringing. Indicates whether or not a melody is currently being played back for testing

0

1

Switched off

Switched on

Notes:

• Before first using ring tones note that the following settings apply:

We have chosen to let you decide your own preferences when you start using ring tones. Therefore, factory setting is AT^SRTC=3,0,0 (ring tones are muted). To activate ring tones for the very first time, first enter the write command and simply change the volume. After applying a firmware update the volume and type selected before the firmware update will be preserved.

• The test ringing signal cannot be activated while an MTC is ringing (ERROR).

• If an MTC arrives during test playback, test ringing will be deactivated and “normal” ringing reactivated (RING).

Likewise, an MOC will also stop test ringing.

• If no optional parameter is entered, the old value will be kept.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 224

Chapter 18 – Hardware-Related Commands

Chapter 18. Hardware-Related

Commands

The AT Commands described in this chapter are related to the Multi-Tech wireless modem’s hardware interface.

18.1 AT+CCLK Real Time Clock

Test Command Syntax: AT+CCLK=?

Response: OK

Read Command Syntax: AT+CCLK?

Response: +CCLK: <time>

OK

Write Command Synatx: AT+CCLK=<time>

Response: +CME ERROR: <err>

ERROR

OK

Parameter Description:

<time>

Format is “yy/mm/dd,hh:mm:ss”, where the characters indicate the two last digits of the year, followed by month, day, hour, minutes, seconds; for example 6

Factory default is “02/01/01,00:00:00” th

of July 2005, 22:10:00 hours equals to “05/07/06,22:10:00”

Notes:

• <time> is retained if the device enters the Power Down mode via AT^SMSO.

• <time> will be reset to its factory default if power is totally disconnected. In this case, the clock starts with

<time>= “02/01/01,00:00:00” upon next power-up.

• Each time the Multi-Tech wireless modem is restarted it takes 2s to re-initialize the RTC and to update the current time. Therefore, it is recommended to wait 2s before using the commands AT+CCLK and AT+CALA

(for example 2s after ^SYSSTART has been output).

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 225

Chapter 18 – Hardware-Related Commands

18.2

AT+CALA Set Alarm Time

Description: The write command sets an alarm time in the ME or clears a programmed alarm. When the alarm time is reached and the alarm is executed, the ME returns an Unsolicited Result Code

(URC) and the alarm time is reset to “00/01/01,00:00:00”.

The alarm can adopt two functions, depending on whether or not you switch the GSM engine off after setting the alarm:

• Reminder message: You can use the alarm function to generate reminder messages. For this purpose, set the alarm as described below and do not switch off or power down the

ME. When executed, the message comes as an Unsolicited Result Code, which reads

“+CALA”.

• Airplane mode: The alarm function can be used to wake up the ME at a scheduled time.

For this purpose, set the alarm as described below. Then power down the ME by entering the AT^SMSO command. When the alarm time is reached the ME enters the Airplane mode, notified to the user by the URC "^SYSSTART AIRPLANE MODE" and, if available, by a user defined text message (specified with <text>). In Airplane mode, the RF interface of the ME is shut down to prevent it from unintentionally logging into the GSM network. All

AT commands whose execution requires a radio connection are disabled. A list of AT commands supported during Airplane mode can be found in Section 20.4, Availability of

AT Commands Depending on Operating Mode of ME. To return from Airplane mode to

Normal mode use the AT^SCFG command and set the parameter <map> to "off". This immediately activates the RF interface and restores access to all AT commands. The

URC "^SYSSTART" notifies the user that the ME has returned to Normal mode. Please note that setting an alarm with AT+CALA is one method to wake up into Airplane mode.

The second approach is using the AT^SCFG command, parameter <mapos>. For further detail on Airplane mode refer to Section 2.14, AT^SCFG.

The test command returns supported array index values <n>, alarm types <type>, and the maximum length of the text <tlength> to be output.

The read command returns the list of current alarm settings in the ME.

Test Command Syntax: AT+CALA=?

Response: +CALA: (list of supported<n>s), (list of supported<type>s), (list of supported<tlength>s)

OK

ERROR

+CME ERROR: <err>

Read Command Syntax: AT+CALA?

Response: +CALA: <time>[, <n>[, <type>[, <text>]]]

OK

ERROR

+CME ERROR: <err>

Write Command Syntax: AT+CALA=<time>[, <n>[, <type>[, <text>]]]

Response: OK

ERROR

Unsolicited Result Codes:

+CALA: <text> Indicates reminder message.

After power-down and wake-up at the scheduled time, the following URC indicates that the ME has entered the

Airplane mode:

"^SYSSTART AIRPLANE MODE"

+CALA: [<text>]

Parameter Descriptions:

<time>

Format is “yy/MM/dd,hh:mm:ss”. For example, 6 th

of July 2005, 22:10:00 hours equals to “05/07/06,22:10:00”

(see also AT+CCLK). Note: if <time> equals current date and time or is set to an earlier date, TA returns +CME

ERROR: 21. To clear a given alarm before its scheduled time, simply enter an empty string for parameter

<time>.

<n>

Integer type value indicating the array index of the alarm.

The ME allows to set only one alarm at a time. Therefore, the list of supported alarm events indicated by the test command AT+CALA=? is <n>=0. If a second alarm time is set, the previous alarm will be deleted. Therefore, the read command AT+CALA? will always return <n>=0. This is also true if individual settings are made on ASC0 or the various Multiplexer channels. For details, see notes below.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 226

Chapter 18 – Hardware-Related Commands

<type>

Integer type value indicating the type of the alarm.

0 Alarm indication: text message via serial interface.

<text>

String type value indicating the text to be displayed when alarm time is reached; maximum length is <tlength>.

By factory default, <text> is undefined.

Note: <text> will be stored to the non-volatile flash memory when the device enters the Power Down mode via

AT^SMSO. Once saved, it will be available upon next power-up, until you overwrite it by typing another text. This eliminates the need to enter the full string when setting a fresh alarm.

<text> should not contain characters which are coded differently in ASCII and GSM (e.g., umlauts). See also

“Supported character sets” and “GSM alphabet tables”.

<tlength>

Integer type value indicating the maximum length of <text>. The maximum length is 16.

Notes:

• After the alarm was executed the parameter <time> of AT+CALA will be reset to “00/01/01,00:00:00”, but

<text> will be preserved as described above.

• If the Multi-Tech wireless modem is totally disconnected from power supply, the most recently saved configuration of +CALA:

<time>[,<n>[,<type>[,<text>]]] will be presented when the Multi-Tech wireless modem is powered up.

• Each time the Multi-Tech wireless modem is restarted it takes 2s to re-initialize the RTC and to update the current time. Therefore, it is recommended to wait 2s before using the commands AT+CCLK and AT+CALA

(for example 2s after ^SYSSTART has been output).

• Alarm settings on ASC0 and Multiplexer channels (see AT+CMUX):

∗ On each interface an individual <text> message can be stored, but only one time setting applies. This means an alarm <time> set on one of the interfaces overwrites the time setting on all remaining interfaces.

Therefore, the total number of alarm events returned by the read command AT+CALA? will always be

<n>=0, no matter whether different text messages are stored.

∗ When the alarm is timed out and executed, the ME sends the URC only on the interface where the most recent alarm setting was made. The alarm time will be reset to “00/01/01,00:00:00” on all interfaces.

Examples:

Example 1

You may want to configure a reminder call for July 31, 2005, at 9.30h, including the message “Good Morning”.

AT+CALA=”05/07/31,09:30:00”,0,0,”Good Morning”

OK

Do not switch off the GSM engine. When the alarm is executed the ME returns the following URC:

+CALA: Good Morning

Example 2

To set a fresh alarm using the same message as in Example 1, simply enter date and time. <n>, <type>, <text>,

<tlength> can be omitted:

AT+CALA=”05/07/31,08:50:00”

OK

When the alarm is executed the URC comes with the same message:

+CALA: Good Morning

Example 3

To enable the ME to wake up into Airplane mode; e.g., on July 20, 2005, at 8.30h, enter:

AT+CALA="05/07/20,08:30:00"

OK

Next, power down the ME:

AT^SMSO

^SMSO: MS OFF

OK

^SHUTDOWN

When the alarm is executed the ME wakes up to Airplane mode and displays a URC. If available, this line is followed by the individual <text> most recently saved. If no individual message was saved only the first line appears.

"^SYSSTART AIRPLANE MODE"

+CALA: Good Morning

Example 4

To delete an alarm before its scheduled time is reached, enter an empty string for the <time> parameter. This will restore the default time and clear any individual message defined with <text>.

AT+CALA=” “

OK

AT+CALA?

+CALA: “00/01/01, 00:00:00” , 0,0, “ “

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 227

Chapter 18 – Hardware-Related Commands

18.3 Intentionally Omitted

18.4 Intentionally Omitted

18.5 AT^SCTM Set Critical Operating Temperature

Presentation Mode or Query Temperature

Description: Use this command to monitor the temperature range of the module.

CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report mode: URCs can be always displayed regardless of the selected mode <n> .

write command enables or disables the presentation of URCs to report critical temperature limits.

read command returns:

• the URC presentation mode.

• information about the current temperature range of the module.

Select <n> to enable or disable the presentation of the URCs. Please note that the setting will not be stored upon Power Down; i.e., after restart or reset, the default <n>=0 will be restored. To benefit from the URCs <n>=1 needs to be selected every time you reboot the

GSM engine.

Test Command Syntax: AT^SCTM=?

Response: ^SCTM:(list of supported <n>s)

OK

Read Command Syntax: AT^SCTM?

Response: ^SCTM: <n>, <m>

OK

ERROR

ERROR

Write Command Syntax: AT^SCTM=<n>

Response: OK

ERROR

Parameter Descriptions:

<n>

0

1

Presentation of URCs is disabled (except for <m> equal to -2 or +2). Default.

Presentation of URCs is enabled.

<M>

-2

-1

0

1

2

Below lowest temperature limit (causes immediate switch-off)

Below low temperature alert limit

Normal operating temperature

Above upper temperature alert limit

Above uppermost temperature limit (causes immediate switch-off)

Notes:

• Please refer to the “Hardware Interface Description” for specifications on critical temperature ranges.

• To avoid damage the module will shut down once the critical temperature is exceeded.

The procedure is equivalent to the power-down initiated with AT^SMSO.

• URCs indicating the alert level “1” or “-1” are intended to enable the user to take appropriate precautions, such as protect the module from exposure to extreme conditions, or save or back up data etc.

The presentation of “1” or “-1” URCs depends on the settings selected with the write command:

If <n>=0: Presentation is enabled for 15 s time after the module was switched on. After 15 s operation, the presentation will be disabled; i.e., no URCs will be generated.

If <n>= 1: Presentation of “1” or “-1” URCs is always enabled.

• Level “2” or “-2” URCs are followed by immediate shutdown. The presentation of these URCs is always enabled; i.e., they will be output even though the factory setting AT^SCTM=0 was never changed.

• If the temperature limit is exceeded while an emergency call is in progress the engine continues to measure the temperature and to deliver alert messages, but deactivates the shutdown functionality. Once the call is terminated full temperature control will be resumed. If the temperature is still out of range ME switches off immediately.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 228

Chapter 18 – Hardware-Related Commands

Unsolicited Result Codes:

URC 1

URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level or when it is back to normal.

URC 2

^SCTM_B: <m> for module (board) temperature

Examples:

Example 1

URCs issued when the operating temperature is out of range:

^SCTM_B: 1

^SCTM_B: 2

^SCTM_B: -1

Caution: Engine close to overtemperature limit.

Alert: Engine is above overtemperature limit and switches off.

Caution: Engine close to undertemperature limit.

^SCTM_B: -2 Alert: Engine is below undertemperature limit and switches off.

Example 2

URCs issued when the temperature is back to normal (URC is output once):

^SCTM_B: 0 Engine back to normal temperature.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 229

Chapter 18 – Hardware-Related Commands

18.6 AT^SSYNC Configure SYNC Pin

Description: The AT^SSYNC command serves to configure the SYNC pin of the application interface.

Please note that the SYNC pin may be assigned different functions: Depending on the design of the host application, the pin can either be used to indicate the current consumption in a transmit burst or to drive a status LED connected to the specified pin.

Before changing the mode of the SYNC pin, carefully read the technical specifications.

Test Command Syntax: AT^SSYNC=?

Response: ^SSYNC:list of supported <mode>s

OK

Read Command Syntax: AT^SSYNC?

Response: ^SSYNC:<mode>

OK

Write Command Syntax: AT^SSYNC=<mode>

Response: OK

Parameter Description:

<mode>

0

1

Operation mode of the SYNC pin.

SYNC mode:

Enables the SYNC pin to indicate growing power consumption during a transmit burst.

You can make use of the signal generated by the SYNC pin, if power consumption is your concern. To do so, ensure that your application is capable of processing the signal. Your platform design must be such that the incoming signal causes other components to draw less current. In short, this allows your application to accommodate current drain and thus, supply sufficient current to the GSM engine if required.

LED mode:

Enables the SYNC pin to drive a status LED installed in your application.

The coding of the LED is described in Section 18.6.1, ME status indicated by status LED patterns.

LED mode:

Like <mode>=1, but additionally, enables different LED signals in SLEEP mode depending on the status of PIN authentication and network registration. See AT+CFUN for SLEEP mode details.

18.6.1 ME Status Indicated by Status LED Patterns

The following table lists the possible patterns of status LED behavior and describes the ME operating status indicated by each pattern if AT^SSYNC parameter <mode>=1 and <mode>=2.

Table 18.2: Modes of the LED and indicated ME functions.

LED Behavior

Permanently off

600 ms on / 600ms off

75 ms on / 3 s off

75 ms on / 75 ms off /

75 ms on / 3 s off

ME operating status if AT^SSYNC=1 ME operating status if AT^SSYNC=2

ME is in one of the following modes:

POWER DOWN mode, AIRPLANE mode, SLEEP mode with no wake-up event in progress.

ME is in the following mode:

POWER DOWN mode and

AIRPLANE mode.

Same as for AT^SSYNC=1 Limited Network Service: No SIM card inserted or no PIN entered, or network search in progress, or ongoing user authentication, or network login in progress.

This applies whether the ME works at full functionality level AT+CFUN=1 or has entered a “temporary wake-up state” during one of the CYCLIC SLEEP modes.

IDLE mode: The mobile is registered to the GSM network (monitoring control channels and user interactions). No call

Same as for AT^SSYNC=1 is in progress.

The same LED pattern applies when the ME enters a “temporary wake-up state during one of the CYCLIC SLEEP modes (e.g., after characters have been received on the serial interface).

One or more GPRS contexts activated. Same as for AT^SSYNC=1

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 230

Chapter 18 – Hardware-Related Commands

LED Behavior

500 ms on / 25 ms off

Permanently on n *600 ms on /n *600 ms off n * 75 ms on / n * 3 ms off n * 500 ms on / n * 25 ms off

ME operating status if AT^SSYNC=1 ME operating status if AT^SSYNC=2

Packet switched data transfer in progress.

Same as for AT^SSYNC=1

Same as for AT^SSYNC=1 Depending on type of call:

Voice call: Connected to remote party.

Data call: Connected to remote party or exchange of parameters while setting up or disconnecting a call.

This applies no matter whether the ME works at full functionality level

AT+CFUN=1 or in one of the CYCLIC

SLEEP modes where it wakes up only temporarily to make the call.

Not possible: With AT^SSYNC=1, LED signal is disabled in SLEEP mode.

SLEEP mode is activated (AT+CFUN parameter <fun> ≠ 1), but the ME is not registered to the GSM network

(e.g., SIM not inserted or PIN not entered, and therefore, either no network service or only Limited

Network Service is available.

Not possible: With AT^SSYNC=1, LED signalization is disabled in SLEEP mode.

Not possible: With AT^SSYNC=1, LED signalization is disabled in SLEEP mode.

SLEEP mode is activated (AT+CFUN parameter <fun> ≠ 1) while the ME is registered to the GSM network.

SLEEP mode is activated (AT+CFUN parameter <fun> ≠ 1) while the ME is registered to the GSM network.

Additionally, PDP context is activated.

Note: When the ME is in Limited Service or IDLE mode with/without PDP context activated, the on/off time ratio of the LED is always the same, no matter whether or not power saving is enabled. The only difference is that in

SLEEP mode the duration of the on/off periods is a multiple n of the equivalent periods without SLEEP mode.

The multiple n is synchronous to the active state of CTS during SLEEP mode (where CTS is set/reset every 0.9 -

2.7 seconds). See also AT+CFUN for the timing of CTS.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 231

Chapter 19 – Miscellaneous Commands

Chapter 19. Miscellaneous

Commands

The AT Commands described in this chapter are related to various areas.

19.1 A/ Repeat Previous Command Line

Description: Repeat previous command line.

Exec Command Syntax: A/

Response: NA

Notes:

• Line does not need to end with terminating character.

• After beginning with the character “a” or “A” a second character “t”, “T” or “/” has to follow. In case of using a wrong second character, it is necessary to start again with character “a” or “A”.

• If autobauding is active, the command A/ cannot be used (see AT+IPR).

19.2 ATS3 Set Command Line Termination

Character

Description: The ATS3 command determines the character recognized by the TA to terminate an incoming command line.

Read Command Syntax: ATS3?

Response: <n>

OK

Write Command Syntax: ATS3=<n>

Response: OK

ERROR

Parameter Description:

<n>

Command line termination character

000.....127 Default = 13.

Notes:

• Using a value other than the default 13 may cause problems when entering commands.

• Whenever you change the setting, take into account that the new value has no effect on the URC

“^SHUTDOWN”.

19.3 ATS4 Set Response Formatting Character

Description: The information text.

Read Command Syntax: ATS4?

Response: <n>

OK

Write Command Syntax: ATS4=<n>

Response: OK

ERROR

Parameter Description:

<n>

Response formatting character

000....127 Default = 10

Note:

Whenever you change the setting take into account that the new value has no effect on the URC

“^SHUTDOWN”.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 232

Chapter 19 – Miscellaneous Commands

19.4 ATS5 Write Command Line Editing Character

Description: This parameter setting determines the character recognized by TA as a request to delete the immediately preceding character from the command line.

Read Command Syntax: ATS5?

Response: <n>

OK

Write Command Syntax: ATS5=<n>

Response: OK

ERROR

Parameter Description:

<n>

Command line editing character

000....127 Default = 8

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 233

Chapter 20 – Summary Tables

Chapter 20. Summary Tables

20.1 Restricted Access to SIM Data after SIM PIN

Authentication

Users should be aware that when using a phonebook, SMS or Remote SAT command quickly after SIM PIN authentication the SIM data may not yet be accessible, resulting in a short delay before the requested AT command response is returned. This delay is due to the initial process of loading SIM data once after SIM PIN authentication.

The duration of loading SIM data is dependent on the SIM card used and may take a couple of seconds.

The "^SSIM READY" URC enabled with AT^SSET can be used to notify the user when the ME has finished reading the SIM card and SIM data are accessible after SIM PIN authentication. Of course, all phonebook and SMS commands may be issued before the URC is delivered. In this case the AT command response (for example the complete phonebook) will appear after the delay mentioned above, but before the AT^SSET is displayed. See example below.

Example:

AT^SSET=1

OK

AT&W

Activate the "^SSIM READY" URC.

Store the presentation mode of the "^SSIM READY" URC to the user profile.

OK

AT+CFUN=1,1

OK

^SYSSTART

AT+CPIN

OK

AT+CPBW=50,"+4030123456789",145,"Paul"

OK

^SSIM READY

Restart the ME.

The ME was restarted.

Enter the SIM PIN.

Write a new phonebook record.

AT+CPBR=50,50

+CPBR: 50,"+4030123456789",145,"Paul"

The URC now confirms that the ME has finished reading data from the SIM.

Read the phonebook entered before.

The phonebook entry was properly saved.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 234

Chapter 20 – Summary Tables

20.2 Star-Hash (*#) Network Commands

The following command strings can be sent to the network via ATD and have to be terminated with a semicolon.

The command strings are defined with GSM 2.30.

Table 20.1 Star-Hash (*#) Overview (Abbreviations used in this table on defined on the following page)

Star-Hash Code

Phone Security

*#06#

**04[2]*oldPin[2]*newPin[2]*new-

Pin[2]#

**05[2]*unblKey[2]*newPin[2]*new-

Pin[2]#

*#0003*MasterPhoneCode#

Functionality

Query IMEI

Change SIM pwd

Change/Unblocking SIM pwd

Response, also refer to Table 20.3

<IMEI> OK

+CME ERROR: <err> / OK

+CME ERROR: <err> / OK

[]03*[ZZ]*oldPw*newPw*newPw#

Phone Number Presentation

*#30#

*#31#

*31#<Phonenumber>[;]

#31#<Phonenumber>[;]

*#76#

C[C] in call

USSD Messages

[C]...[C]#

C[C] (excluded 1[C])

Unlock “PS” lock with Master Phone

Code

Registration of net password

Check status of CLIP (Calling Line

Identification Presentation)

Check status of CLIR (Calling Line

Identification Restriction)

Suppress CLIR

Activate CLIR

Check status of COLP (Connected

Line Identification Presentation)

+CME ERROR: <err> / OK

+CME ERROR: <err> / OK

(see AT+CLIR)

(see AT+CLIR)

+COLP : <n>,<m> OK (see

AT+COLP)

*#77# Check status of COLR (Connected

Line Identification Restriction)

Call Forwarding

(choice of *,#,*#,**,##)21*DN*BS# Act/deact/int/reg/eras CFU

(choice of

*,#,*#,**,##)004*DN*BS*T#

Call Waiting

(choice of *,#,*#)43*BS# Activation/deactivation/int WAIT

+COLR : 0,<m> OK (where <m> = active or not active)

(choice of *,#,*#,**,##)67*DN*BS# Act/deact/int/reg/eras CF busy

^SCCFC : <reason>, <status>,

<class> [,...] like +CCFC *) (see

AT+CCFC) see above

(choice of *,#,*#,**,##)61*DN*BS*T# Act/deact/int/reg/eras CF no reply see above

(choice of *,#,*#,**,##)62*DN*BS# Act/deact/int/reg/eras CF no reach see above

(choice of

*,#,*#,**,##)002*DN*BS*T#

Act/deact/int/reg/eras CF all see above

Act/deact/int/reg/eras CF all cond. see above

+CCWA : <status>, <class> [,...] like

+CCWA *) (see: AT+CCWA)

Call Barring

(choice of *,#,*#)33*Pw*BS# Act/deact/int BAOC

(choice of *,#,*#)331*Pw*BS#

(choice of *,#,*#)332*Pw*BS#

Act/deact/int BAOIC

Act/deact/int BAOIC exc.home

^SCLCK : <fac>, <status>, <class>

[, ...] like +CLCK *) (See AT+CLCK) see above see above

(choice of *,#,*#)35*Pw*BS#

(choice of *,#,*#)351*Pw*BS#

#330*Pw*BS#

#333*Pw*BS#

#353*Pw*BS#

Call Hold / Multiparty

Act/deact/int. BAIC

Act/deact/int BAIC roaming

Deact. All Barring Services

Deact. All Outg.Barring Services

Deact. All Inc.Barring Services see above see above see above see above see above

Call hold and multiparty

Send USSD message

Send USSD message

+CLIP : <n>,<m> OK (see AT+CLIP)

+CLIR : <n>,<m> OK (see AT+CLIR)

+CME ERROR: <err> / OK

+CME ERROR: <err> / OK

+CME ERROR: <err> / OK

*) Notes on ^SCCFC, +CCWA, ^SCLCK: The output depends on the affected basic service of the Star-Hash code. One line will be output for every tele- or bearer service coded in basic service code BS.

^SCCFC and ^SCLCK are modified by giving an additional <reason> or <fac> in front of the regular output string generated by the standard commands +CCFC and +CLCK.

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 235

Chapter 20 – Summary Tables

Table 20.2 Abbreviations of Codes and Parameters used in Star-Hash Network Commands Table Above

Abbreviation Meaning

ZZ Type of supplementary services:

DN

BS

T

Barring services

All services

Dialing number

Basic service equivalent to parameter class:

Voice

FAX

SMS

SMS+FAX

Data circuit asynchron

Data circuit synchron dedicated PAD access dedicated Packet access

Data circuit asynchron+PAD

Data circuit synchron+Packet

Data circuit asynchron+synchron+Packet+PAD

All Services

Time in seconds

Value

330

Not specified

String of digits 0-9

11

13

16

12

25

24

27

26

21

22

20

--

In contrast to AT+CCFC, parameter T has no default value. If T is not specified, an operator defined default or the last known value may be used, depending on the network operator.

--

--

PW Password

C Character of TE character set (e.g., astericks, hash or digit in case of USSD, or digits in case of held calls or multiparty calls)

Table 20.3 Star-Hash Command Response Parameters

Parameter

<m>

<n>

<status>

<class>

<fac>

<reason>

Meaning

Mode: 0 = not active, 1 = active

Unsolicited result code: 0 = presentation disabled, 1 = presentation enabled

Status: 0 = not active, 1 = active

Represents BS = basic service, refer to AT+CCFC, AT+CLCK

Facility lock, refer to AT+CLCK

Call forwarding reason

For exact specification of format and parameters for Star-Hash commands refer to GSM 02.04, Table 3.2 and

GSM 02.30, Annex C.

Table 20.4 Star-Hash Commands for Supplementary Services

Star-Hash Code

*

**

*#

#

##

Abbreviations in Table 20.1 act reg int deact eras

Functionality

Activate (except for CLIR, see list above)

Register and activate

Check status (interrogate)

Deactivate (except for CLIR, see list above)

Unregister and deactivate

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 236

Chapter 20 – Summary Tables

20.3 AT Commands and SIM PIN Dependency

Table 20.5: Available AT Commands and Dependency on SIM PIN.

AT Command not available

AT Command does not require PIN 1

AT Command requires PIN 1

AT Command sometimes requires PIN 1

AT Command Exec

Configuration Commands

AT&F

AT&V

AT&W

ATQ

ATV

ATX

AT \ V

ATZ

AT+CFUN

AT^SMSO

AT+GCAP

AT+CMEE

AT+CSCS

AT^SCFG

Status Control Commands

AT+CMER

AT+CIND

AT^SIND

AT+CEER

ATS18

AT+CPAS

AT+WS46

Serial Interface Control Commands

AT\Q

AT&C

Test

AT&D

AT&S

ATE

AT+ICF

AT+IFC

AT+ILRR

AT+IPR

AT+CMUX

AT+STPB

Security Commands

AT+CPIN

AT+CPIN2

AT^SPIC

AT+CLCK

AT^SLCK

AT+CPWD

AT^SPWD

AT^SCSL

Identification Commands

ATI

AT+CGMI

AT+GMI

AT+CGMM

AT+GMM

AT+CGMR

AT+GMR

AT+CGSN

AT+GSN

AT+CIMI

Read Write

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 237

AT Command Exec

Call-Related Commands

ATA

ATD

ATD><mem><n>

ATD><n>

ATD><str>

ATDI

ATDL

ATH

AT+CHUP

AT+SHUP

ATS0

ATS6

ATS7

ATS8

ATS10

ATO

+++

AT+CBST

AT+CRLP

AT+CLCC

AT^SLCC

AT+CR

AT+CRC

AT+CSNS

AT^SCNI

AT^SLCD

AT^STCD

ATP

ATT

Network Service Commands

AT+COPN

AT+COPS

AT^SOPS

AT+CREG

AT+CSQ

AT^SMONC

AT^SMOND

AT^MONI

AT^MONP

AT^SMONG

AT^SALS

AT^SHOM

AT^SPLM

AT^CPOL

AT^SPLR

AT^SPLW

Supplementary Service Commands

AT+CACM

AT^SACM

AT+CAMM

AT+CAOC

AT+CCUG

AT+CCFC

AT+CCWA

AT+CHLD

AT+CLIP

AT+CLIR

AT+COLP

AT+CPUC

AT+CSSN

AT+CUSD

Test

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B)

Read

Chapter 20 – Summary Tables

Write

238

Internet Service Commands

AT^SICS

AT^SISS

AT^SISO

AT^SISC

AT^SISR

AT^SISW

GPRS Commands

AT+CGACT

AT+CGANS

AT+CGATT

AT+CGAUTO

AT+CGDATA

AT+CGDCONT

AT+CGEQMIN

AT+CGEQREQ

AT+CGPADDR

AT+CGQMIN

AT+CGQREQ

AT+CGREG

AT+CGSMS

AT^SGACT

AT^SGAUTH

AT^SGCONF

ATA

ATD*99#

ATD*98#

ATH

ATS0

FAX Commands

AT+FCLASS

AT+FRH

AT+FRM

AT+FRS

AT+FTH

AT+FTM

AT+FTS

Short Message Service (SMS) Commands

AT+CMGC

AT+CMGD

AT+CMGF

AT+CMGL

AT+CMGR

AT+CMGS

AT+CMGW

AT+CMSS

AT+CNMA

AT+CNMI

AT+CPMS

AT+CSCA

AT+CSCB

AT+CSDH

AT+CSMP

AT+CSMS

AT^SCML

AT^SCMR

AT^SCMS

AT^SCMW

AT^SLMS

AT^SMGL

AT^SMGO

AT^SMGR

AT^SSCONF

AT^SSDA

AT^SSMSS

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B)

Chapter 20 – Summary Tables

239

SIM-Related Commands

AT+CRSM

AT^SXSM

AT^SCKS

AT^SSET

AT^SCID

AT+CXXCID

SIM Application Toolkit (SAT) Commands

AT^SSTA

^SSTN

AT^SSTGI

AT^SSTR

Phonebook Commands

AT+CNUM

AT+CPBR

AT+CPBS

AT+CPBW

AT^SDLD

AT^SPBC

AT^SPBD

AT^SPBG

AT^SPBS

Audio Commands

ATL

ATM

AT+CLVL

AT+CMUT

AT+VTD

AT+VTS

AT^SAIC

AT^SNFA

AT^SNFD

AT^SNFI

AT^SNFM

AT^SNFO

AT^SNFPT

AT^SNFS

AT^SNFTTY

AT^SNFV

AT^SNFW

AT^SRTC

Hardware-Related Commands

AT+CALA

AT+CCLK

AT^SCTM

AT^SSYNC

Miscellaneous Commands

A/

ATS3

ATS4

ATS5

Chapter 20 – Summary Tables

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 240

Chapter 20 – Summary Tables

20.4 Availability of AT Commands Depending on

Operating Mode of ME

Table 20.6: Availability of AT Commands Depending on Operating Mode of ME.

Command not supported

Command supported

Use in Airplane Mode depends on command type (test, read, execute, write). See description of AT command for details.

AT Command Normal Mode Airplane Mode

Configuration Commands

AT&F

AT&V

AT&W

ATQ

ATV

ATX

AT \ V

ATZ

AT+CFUN

AT^SMSO

AT+GCAP

AT+CMEE

AT+CSCS

AT^SCFG

Status Control Commands

AT+CMER

AT+CIND

AT^SIND

AT+CEER

ATS18

AT\Q

AT&C

AT&D

AT&S

AT+CPAS

AT+WS46

Serial Interface Control Commands

ATE

AT+ICF

AT+IFC

AT+ILRR

AT+IPR

AT+CMUX

AT+STPB

Security Commands

AT+CPIN

AT+CPIN2

AT^SPIC

AT+CLCK

AT^SLCK

AT+CPWD

AT^SPWD

AT^SCSL

Identification Commands

ATI

AT+CGMI

AT+GMI

AT+CGMM

AT+GMM

AT+CGMR

AT+GMR

AT+CGSN

AT+GSN

AT+CIMI

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 241

AT Command Normal Mode Airplane Mode

Call-Related Commands

ATA

ATD

ATD><mem><n>

ATD><n>

ATD><str>

ATDI

ATDL

ATH

AT+CHUP

AT+SHUP

ATS0

ATS6

ATS7

ATS8

ATS10

ATO

+++

AT+CBST

AT+CRLP

AT+CLCC

AT^SLCC

AT+CR

AT+CRC

AT+CSNS

AT^SCNI

AT^SLCD

AT^STCD

ATP

ATT

Network Service Commands

AT+COPN

AT+COPS

AT^SOPS

AT+CREG

AT+CSQ

AT^SMONC

AT^SMOND

AT^MONI

AT^MONP

AT^SMONG

AT^SALS

AT^SHOM

AT^SPLM

AT^CPOL

AT^SPLR

AT^SPLW

Supplementary Service Commands

AT+CACM

AT^SACM

AT+CAMM

AT+CAOC

AT+CCUG

AT+CCFC

AT+CCWA

AT+CHLD

AT+CLIP

AT+CLIR

AT+COLP

AT+CPUC

AT+CSSN

AT+CUSD

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B)

Chapter 20 – Summary Tables

242

Internet Service Commands

AT^SICS

AT^SISS

AT^SISO

AT^SISC

AT^SISR

AT^SISW

GPRS Commands

AT+CGACT

AT+CGANS

AT+CGATT

AT+CGAUTO

AT+CGDATA

AT+CGDCONT

AT+CGEQMIN

AT+CGEQREQ

AT+CGPADDR

AT+CGQMIN

AT+CGQREQ

AT+CGREG

AT+CGSMS

AT^SGACT

AT^SGAUTH

AT^SGCONF

ATA

ATD*99#

ATD*98#

ATH

ATS0

FAX Commands

AT+FCLASS

AT+FRH

AT+FRM

AT+FRS

AT+FTH

AT+FTM

AT+FTS

Short Message Service (SMS) Commands

AT+CMGC

AT+CMGD

AT+CMGF

AT+CMGL

AT+CMGR

AT+CMGS

AT+CMGW

AT+CMSS

AT+CNMA

AT+CNMI

AT+CPMS

AT+CSCA

AT+CSCB

AT+CSDH

AT+CSMP

AT+CSMS

AT^SCML

AT^SCMR

AT^SCMS

AT^SCMW

AT^SLMS

AT^SMGL

AT^SMGO

AT^SMGR

AT^SSCONF

AT^SSDA

AT^SSMSS

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B)

Chapter 20 – Summary Tables

243

SIM-Related Commands

AT+CRSM

AT^SXSM

AT^SCKS

AT^SSET

AT^SCID

AT+CXXCID

SIM Application Toolkit (SAT) Commands

AT^SSTA

^SSTN

AT^SSTGI

AT^SSTR

Phonebook Commands

AT+CNUM

AT+CPBR

AT+CPBS

AT+CPBW

AT^SDLD

AT^SPBC

AT^SPBD

AT^SPBG

AT^SPBS

Audio Commands

ATL

ATM

AT+CLVL

AT+CMUT

AT+VTD

AT+VTS

AT^SAIC

AT^SNFA

AT^SNFD

AT^SNFI

AT^SNFM

AT^SNFO

AT^SNFPT

AT^SNFS

AT^SNFTTY

AT^SNFV

AT^SNFW

AT^SRTC

Hardware-Related Commands

AT+CALA

AT+CCLK

AT^SCTM

AT^SSYNC

Miscellaneous Commands

A/

ATS3

ATS4

ATS5

Chapter 20 – Summary Tables

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 244

Chapter 20 – Summary Tables

20.5 AT Command Settings Storable with AT&W

Table 20.7: Settings Stored to User Profile on ASC0 / MUX Channel 1.

AT Command Stored Parameters

Configuration Commands

ATQ <n>

ATV

ATX

<value>

<value>

AT \ V

AT+CMEE

<value>

<errMode>

Status Control Commands

ATS18 <n>

Serial Interface Control Commands

AT\Q <n>

AT&C <value>

AT&D <value>

AT&S <value>

ATE <value>

AT+IFC <TEflowcontrol>, <TAflowcontrol>

AT+ILRR <value>

AT+STPB <n>

Call-Related Commands

ATS0 <n>

ATS6 <n>

ATS7 <n>

ATS8 <n>

ATS10 <n>

AT+CBST

AT+CRLP

<speed>, <name>, <ce>

<iws>, <mws>, <T1>, <N2>

AT^SLCC <n>

AT+CR <mode>

AT+CRC <mode>

Network Service Commands

AT+COPS <format>

AT+CREG <n>

Supplementary Service Commands

AT^SACM <n>

AT+CLIP <n>

GPRS Commands

ATS0 <n>

FAX Commands

AT+FCLASS <n>

Short Message Service (SMS) Commands

AT+CMGF <mode>

AT+CNMI

AT+CSCB

<mode>, <mt>, <bm>, <ds>, <bfr>

<mode>

AT+CSDH <show>

AT+CSMS <service>

AT^SMGO <n>

SIM-Related Commands

AT^SCKS <mode>

AT^SSET <n>

Miscellaneous Commands

ATS3 <n>

ATS4 <n>

ATS5 <n>

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 245

Chapter 20 – Summary Tables

20.6 Factory Defaults Restorable with AT&F

Table 20.8 Factory Default Settings Restorable with AT&F

AT Command Factory Defaults

Configuration Commands

ATQ <n>=0

ATV <value>=1

ATX

AT \ V

<value>=4

<value>=1

AT+CFUN <fun>=1

AT+CMEE <errMode>=0

AT+CSCS <chset>=”GSM”

<CmgwMode>=1

Status Control Commands

AT+CMER <mode>=0, <keyp>=0, <disp>=0, <ind>=0, <bfr>=0

AT+CIND <mode>=1

ATS18 <n>=0

Serial Interface Control Commands

AT\Q <n>=0

AT&C <value>=1

AT&D <value>=2

AT&S <value>=0

ATE <value>=1

AT+ILRR <value>=0

AT+STPB <n>=0

Call-Related Commands

ATS0 <n> =000

ATS6 <n>=000

ATS7 <n>=060

ATS8 <n>=0

ATS10 <n>=002

AT+CBST

AT+CRLP

<speed>=7, <name>=0, <ce>=1

<iws>=61, <mws>=61, <T1>=78, <N2>=6

AT^SLCC <n>=0

AT+CR <mode>=0

AT+CRC <mode>=0

Network Service Commands

AT+COPS <format>=0

AT+CREG <n>=0

Supplementary Service Commands

AT^SACM <n>=0

AT+CLIP <n>=0

AT+CUSD <n>=0

GPRS Commands

AT+CGAUTO <n>=3

AT+CGSMS <service>=3

AT+SGAUTH <auth>=3

ATS0 <n>=000

FAX Commands

AT+FCLASS <n>=0

Short Message Service (SMS) Commands

AT+CMGF <mode>=0

AT+CNMI <mode>=0, <mt>=0, <bm>=0, <ds>=0, <bfr>=1

AT+CSDH <show>=0

AT+CSMP <fo>=17, <vp>=167, <dcs>=0, <pid>=0

AT+CSMS <service>=0

AT^SMGO <n>=0

AT^SSCONF <ra>=0

AT^SSDA <da>=0

AT^SSMSS <seq>=0

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 246

Chapter 20 – Summary Tables

SIM-Related Commands

AT^SCKS <mode>=0

AT^SSET

Phonebook Commands

<n>=0

AT+CPBS <storage>=”SM”

AT^SPBS <internal-counter>=0

Audio Commands

AT+VTD <duration>=1

Hardware-Related Commands

AT^SCTM <n>=0

Miscellaneous Commands

ATS3 <n>=013

ATS4 <n>=010

ATS5 <n>=008

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 247

Chapter 20 – Summary Tables

20.7 Summary of Unsolicited Result Codes (URC)

Table 20.9 Summary of Unsolicited Result Codes (URC)

AT Command URC

Configuration Commands

AT+CFUN ^SYSSTART

AT^SMSO ^SHUTDOWN

AT^SCFG ^SYSSTART AIRPLANE MODE

Status Control Commands

AT^SIND +CIEV: <indDescr>, <indValue>, <vmCounter>

AT^SIND +CIEV: <indDescr>, <nitzUT>, <nitzTZ>, <nitzDST>

AT^SIND +CIEV: <indDescr>, <indValue>, <indValue>

Call-Related Commands

AT^SLCC if the list of current calls is empty:

^SLCC: if one or more calls are currently in the list:

^SLCC: <idx>, <dir>, <stat>, <mode>, <mpty>, <traffic channel assigned>[, <number>, <type>[, <alpha>]]

[^SLCC: <idx>, <dir>, <stat>, <mode>, <mpty>, <traffic channel assigned>[, <number>, <type>[, <alpha>]]]

[... ]

^SLCC:

AT+CRC RING

AT+CRC +CRING:

Network Service Commands

AT+CREG +CREG: <stat>[, <lac>, <ci>]

Supplementary Service Commands

AT^SACM +CCCM:

AT+CCWA +CCWA: <calling number>, <type of number>, <class>, , <CLI validity>

AT+CCWA ^SCWA

AT+CLIP +CLIP: <number>, <type>, , [, <alpha>][, <CLI validity>]

AT+CLIP

AT+COLP

AT+CSSN

AT+CSSN

+CLIP: <number>, <type>

+COLP: <number>, <type>

+CSSI: <code 1>

+CSSU: <code 2>

Internet Service Commands

AT^SISO ^SIS: <srvProfileId>, <urcCause>[, [<urcInfoId>][, <urcInfoText>]]

AT+SISR

AT+SISW

GPRS Commands

^SISR: <srvProfileId>, <urcCauseId>[, <remainUdpPacketLength>]

^SISW: <srvProfileId>, <urcCauseId>

Short Message Service (SMS) Commands

AT+CNMI +CMTI: <mem3>, <index>

<length><CR><LF><pdu>

AT+CNMI +CMT: <oa>, <scts>[, <tooa>, <fo>, <pid>, <dcs>, <sca>, <tosca>,

<length>]<CR><LF><data>

AT+CNMI +CBM: <sn>, <mid>, <dcs>, <page>, <pages><CR><LF><data>

AT+CNMI +CDS: <fo>, <mr>[, <ra>][, <tora>], <scts>, <dt>, <st>

AT+CNMI +CDSI: <mem3>, <index>

<mode>

SIM-Related Commands

SIM Application Toolkit (SAT) Commands

<cmdType>

<cmdTerminateValue>

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 248

Chapter 20 – Summary Tables

Hardware-Related Commands

254

255

AT^SBC ^SBC: Overvoltage shutdown

<m>

<m>

20.8 AT Commands Not Usable for USB

Serial Interface Control Commands

AT\Q

AT+ICF

AT+IFC

AT+ILRR

AT+IPR

AT^STPB

Audio Commands

ATL

ATM

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 249

Chapter 20 – Summary Tables

20.9 Alphabetical List of AT Commands

Table 20.10 Alphabetical List of AT Commands

Command Description

+++

A/

AT&C

AT&D

AT&F

AT&S

AT&V

AT\ V

AT^MONI

AT^MONP

AT^SACM

AT^SALS

AT^SCFG

AT^SCID

AT^SCKS

AT^SCML

AT^SCMR

AT^SCMS

AT^SCMW

AT^SCNI

AT^SCTM

AT^SDLD

AT^SGACT

AT^SGAUTH

AT^SGCONF

Switch from Data Mode to Command Mode

Repeat Previous Command Line

Set Circuit Data Carrier Detect (DCD) Function Mode

Set Circuit Data Terminal Ready (DTR) Function Mode

Set All Current Parameters to Manufacturer Defaults

Set Circuit DSR Function Mode

Display Current Configuration

Set CONNECT Result Code Format

Control

Operator List

Monitor Idle Mode and Dedicated Mode

Monitor Neighbour Cells

Advice of Charge and Query of ACM and ACMmax

Alternate Line Service

Extended Configuration Settings

Display SIM Card Identification Number

Query SIM and Chip Card Holder Status

List Concatenated Short Messages from Preferred Store

Read Concatenated Short Messages

Send Concatenated Short Messages

Write Concatenated Short Messages to Memory

List Call Number Information

Set Critical Operating Temperature Presentation Mode or Query

Temperature

Delete the ‘Last Number Redial Memory

Query All PDP Context Activations

Set Type of Authentication for PPP Connection

Configuration of GPRS-Related Parameters

Section Page

7.18

19.1

4.2

4.3

2.1

4.4

2.2

2.7

8.14

8.8

8.9

9.2

17.8

8.11

2.14

83

232

51

51

19

52

19

14.5

14.3

13.18

13.19

13.20

13.21

197

196

186

187

188

188

7.26 91

18.5 228

16.6

11.14

11.15

11.16

22

105

100

102

107

216

104

29

207

161

162

162

AT^SHUP

AT^SICS

AT^SIND

AT^SISC

AT^SISO

AT^SISR

Hang Up Call(s) Indicating a Specific GSM04.08 Release Cause

Internet Connection Setup Profile

Extended Indicator Control

Internet Service Close

Internet Service Open

Internet Service Read Data

AT^SISW

AT^SLCC

Internet Service Write Data

List Current Calls of ME

AT^SLCD Display Last Call Duration

Lock

AT^SLMS

AT^SMGL

AT^SMGO

AT^SMGR

List SMS Memory Storage

List Short Messages from Preferred Store without Setting Status to

REC READ

Set or Query SMS Overflow Pesentation Mode or Query SMS

Overflow

Read Short Message without Setting Status to REC READ

7.11

10.1

3.3

10.4

10.3

80

122

39

137

134

10.5

10.2

10.6

7.22

138

125

140

86

7.27 91

68

13.22 189

13.23 189

13.24 190

13.25 190

AT^SMSO

AT^SNFA

AT^SNFD

AT^SNFI

AT^SNFM

AT^SNFO

AT^SNFPT

AT^SNFS

AT^SNFTTY

Monitoring

Monitor

Switch off Mobile Station

Set or Query of Microphone Attenuation

Set Audio Parameters to Manufacturer Default Values

Set Microphone Path Parameters

Set Microphone Audio Path

Set Audio Output (= Loudspeaker Path) Parameter

Set Progress Tones

Select Audio Hardware Set

Signal TTY/CTM Audio Mode Capability

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B)

2.10

17.9

17.10

17.11

17.12

17.13

17.14

17.15

17.16

25

217

218

218

219

220

221

221

222

250

Chapter 20 – Summary Tables

Command

AT^SNFV

AT^SNFW

AT^SOPS

AT^SPBC

AT^SPBD

AT^SPBG

AT^SPBS

Description

Set Loudspeaker Volume

Write Audio Setting in Non-Volatile Store

Extended Operator Selection

Find First Matching Entry in Sorted Phonebook

Purge Phonebook Memory Storage

Display Phonebook Entries in Alphabetical Order

Step Through the Selected Phonebook Alphabetically

AT^SPLM

AT^SPLR

Read the PLMN List

Read Entry from the Preferred Operators List

AT^SPLW Write an Entry to the Preferred Operators List

AT^SPWD Change

AT^SRTC Ring Tone Configuration

AT^SSCONF

AT^SSDA

AT^SSET

AT^SSMSS

SMS Command Configuration

Set SMS Display Availability

Indicate SIM Data Ready

Set Short Message Storage Sequence

AT^SSTA SAT Interface Activation

AT^SSTGI SAT

AT^SSYNC

AT^STCD

AT^SXSM

AT+CACM

AT+CALA

AT+CAMM

AT+CAOC

AT+CBST

AT+CCFC

AT+CCLK

AT+CCUG

AT+CCWA

AT+CEER

AT+CFUN

AT+CGACT

AT+CGANS

AT+CGATT

AT+CGAUTO

AT+CGDATA

AT+CGDCONT

AT+CGEQMIN

AT+CGEQREQ

AT+CGPADDR

AT+CGQMIN

AT+CGQREQ

AT+CGREG

AT+CGSMS

AT+CGSN

AT+CHLD

AT+CHUP

AT+CIMI

AT+CLCC

AT+CLIP

AT+CLIR

AT+CLVL

AT+CMEE

AT+CMER

AT+CMGC

AT+CMGD

Configure SYNC Pin

Display Total Call Duration

Extended SIM Access

Accumulated Call Meter (ACM) Reset or Query

Set Alarm Time

Accumulated Call Meter Maximum (ACMmax) Set or Query

Advice of Charge Information

Select Bearer Service Type

Call Forwarding Number and Conditions Control

Real Time Clock

Closed User Group

Call Waiting

Extended Error Report

Set Phone Functionality

7.19

9.6

18.1

9.5

9.7

3.2

2.9

18.6

7.28

14.2

9.1

18.2

9.3

9.4

Section Page

17.17 223

17.18

8.3

223

95

16.7

16.8

16.9

16.10

207

208

209

211

8.13

8.15

8.16

105

106

106

17.19

13.26

13.27

14.4

224

191

191

197

13.28 192

15.1 198

200

PDP Context Activate or Deactivate

Manual Response to a Network Request for PDP Context Activation

GPRS Attach or Detach

11.1

11.2

11.3

Automatic Response to a Network Request for PDP Context Activation 11.4

Enter Data State 11.5

Define PDP Context

3G Quality of Service Profile (Minimum Acceptable)

3G Quality of Service Profile (Requested)

Show PDP Adress

Quality of Service Profile (Minimum Acceptable)

Quality of Service Profile (Requested)

GPRS Network Registration Status

Select Service for MO SMS Messages

Request International Mobile Equipment Identity

Call Hold and Multiparty

Hang Up Call

Request International Mobile Subscriber Identity

List Current Calls of ME

Calling Line Identification Presentation

Calling Line Identification Restriction

Loudspeaker Volume Level

Mobile Equipment Error Message Format

Mobile Equipment Event Reporting

Send an SMS Command

Delete SMS Message

11.6

11.7

11.8

6.2

6.6

11.9

11.10

11.11

11.12

11.13

6.8

9.8

7.10

6.10

7.21

9.9

9.10

17.4

2.12

3.1

13.2

13.3

85

116

117

214

25

36

174

174

84

110

225

109

112

43

23

230

91

195

107

226

108

108

143

144

145

146

147

148

149

152

71

72

154

155

157

159

160

72

114

80

73

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 251

Chapter 20 – Summary Tables

Command

AT+CMGF

AT+CMGL

AT+CMGR

Description

Select SMS Message Format

List SMS Messages from Preferred Store

Read SMS Messages

AT+CMGS

AT+CMGW

Send SMS Message

Write Short Messages to Memory

AT+CMSS Send Short Messages from Storage

Control

AT+CMUX

AT+CNMA

AT+CNMI

Enter Multiplex Mode

New SMS Message Acknowledge to ME/TE Phase 2+

New Short Message Indication

AT+COLP

AT+COPN

AT+CPAS

AT+CPBR

Read Operator Names

Mobile Equipment Activity Status

Read from Phonebook

AT+CPBS Select Phonebook Memory Storage

AT+CPBW Write into Phonebook

Authentication

Section Page

13.4

13.5

13.6

13.7

13.8

174

175

176

177

178

13.9 179

214

4.10

13.10

13.11

56

179

180

8.1 93

3.6

16.3

49

202

16.4 204

16.5 205

59

AT+CPMS

AT+CPUC

AT+CR

AT+CRC

Preferred SMS Message Storage

Price Per Unit and Currency Table

Service Reporting Control

Set Cellular Result Codes for Incoming Call Indication

13.12

9.12

7.23

7.24

182

118

89

90

AT+CRLP

AT+CRSM

AT+CSCA

AT+CSCB

AT+CSCS

Select Radio Link Protocol Parameters for Originated Non-Transparent

Data Calls

Restricted SIM Access

SMS Service Center Address

Select Cell Broadcast Message Indication

Select TE Character Set

AT+CSDH

AT+CSMP

AT+CSMS

AT+CSNS

Show SMS Text Mode Parameters

Set SMS Text Mode Parameters

Select Message Service

Single Numbering Scheme

AT+CSQ AT+CSQ

AT+CSSN Supplementary Service Notifications

AT+CUSD

AT+CXXCID

AT+FCLASS

AT+FRH

AT+FTH

Supplementary Service Notifications

Display Card ID

Fax: Select, Read or Test Service Class

Receive Data Using HDLC Framing

Data

Silence

Transmit Data Using HDLC Framing

7.20 84

14.1

13.13

13.14

2.13

13.15

13.16

13.17

7.25

9.13

9.14

14.6

12.2

12.3

12.6

193

183

183

29

184

184

185

90

119

120

197

168

169

169

AT+FTS

AT+GCAP

Stop Transmission and Wait

Request Complete TA Capabilities List

AT+GMI Request

AT+GMM Request Model Identification

AT+GMR

AT+GSN

AT+ICF

AT+IFC

AT+ILRR

AT+IPR

AT+STPB

Request Revision Identification

Request International Mobile Equipment Identity

Serial Interface Character Framing

Set Flow Control Separately for Data Directions

Set TE-TA Local Rate Reporting

Set Fixed Local Rate

Transmit Parity Bit (for 7E1 & 7O1 Only)

AT+VTS

AT+WS46

ATA

ATA

ATD

ATD*98#

DTMF and Tone Generation

Select Wireless Network

Answer a Call

Manual Response to a Network Request for PDP Context Activation

Mobile Originated Call to a Specified Number

Request GPRS IP Service

12.8

2.11

6.3

6.5

6.7

6.9

4.6

4.7

4.8

4.9

4.11

17.7

3.7

7.2

11.17

7.3

11.19

215

50

75

163

75

164

170

25

71

71

72

72

52

53

53

54

58

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 252

ATS3

ATS4

ATS5

ATS6

ATS7

ATS8

ATT

ATV

ATX

ATZ

Command

ATD*99#

ATD><mem><n>

ATD><n>

ATD><str>

ATDI

ATDL

ATE

ATH

ATH

ATI

ATL

ATM

ATO

ATP

ATQ

ATS0

ATS0

ATS10

ATS18

Chapter 20 – Summary Tables

Description

Request GPRS Service

Mobile Originated Call Using Specific Memory and Index Number

Mobile Originated Call from Active Memory Using Index Number

Section Page

11.18 163

7.4

7.5

77

78

Mobile Originated Call from Active Memory Using Corresponding Field 7.6

Mobile Originated Call to ISDN Number 7.7

Redial Last Number Used

Enable Command Echo

7.8

4.5

78

79

79

52

Disconnect Existing Connection

Manual Rejection of a Network Request for PDP Context Activation

Display Product Identification Information

Set Monitor Speaker Loudness

Set Monitor Speaker Mode

Switch from Command Mode to Data Mode / PPP Online Mode

7.9

11.20

6.1

17.2

17.3

7.17

Select Pulse Dialing

Set Result Code Presentation Mode

7.29

2.4

Automatic Response to a Network Request for PDP Context Activation 11.21

Set Number of Rings before Automatically Answering a Call 7.12

Set Disconnect Delay after Indicating the Absence of Data Carrier

Extended Call Release Report

7.16

3.5

92

20

165

81

83

49

79

164

71

213

213

83

Set Command Line Termination Character

Set Response Formatting Character

Write Command Line Editing Character

Set Pause before Blind Dialing

Set Number of Seconds to Wait for Connection Completion

Set Number of Seconds to Wait for Comma Dialing Modifier

Select Tone Dialing

Set Result Code Format Mode

Set CONNECT Result Code Format and Call Monitoring

Set all Current Parameters to User Defined Profile

19.2

19.3

19.4

7.13

7.14

7.15

7.30

2.5

2.6

2.8

232

232

233

82

82

82

92

21

22

22

Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 253

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents