Hardware Description & Installation Manual
M869-9902-114
17 December 2014
Notices
Copyright & Trademark Notice
Copyright © 2009–2014, Grass Valley USA, LLC. All rights reserved.
Belden, Belden Sending All The Right Signals, and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions. Grass Valley, Miranda, Kaleido-X16, Kaleido-X, iControl, and Densité are trademarks or registered trademarks of Grass Valley USA, LLC. Belden Inc., Grass Valley USA,
LLC, and other parties may also have trademark rights in other terms used herein.
Terms and Conditions
Please read the following terms and conditions carefully. By using Kaleido multiviewer documentation, you agree to the following terms and conditions.
Grass Valley hereby grants permission and license to owners of Kaleido multiviewers to use their product manuals for their own internal business use. Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose unless specifically authorized in writing by Grass Valley.
A Grass Valley manual may have been revised to reflect changes made to the product during its manufacturing life. Thus, different versions of a manual may exist for any given product. Care should be taken to ensure that one obtains the proper manual version for a specific product serial number.
Information in this document is subject to change without notice and does not represent a commitment on the part of Grass Valley.
Warranty information is available in the Support section of the Grass Valley Web site
(www.grassvalley.com).
ii
Title Kaleido-X16 Hardware Description & Installation Manual
Part Number M869-9902-114
Revision 17 December 2014, 5:06 pm
Kaleido-X16
Hardware Description & Installation Manual
Important Safeguards and Notices
This section provides important safety guidelines for operators and service personnel.
Specific warnings and cautions appear throughout the manual where they apply. Please read and follow this important information, especially those instructions related to the risk of electric shock or injury to persons.
Symbols and Their Meanings
Indicates that dangerous high voltage is present within the equipment enclosure that may be of sufficient magnitude to constitute a risk of electric shock.
Indicates that the user, operator or service technician should refer to the product manuals for important operating, maintenance, or service instructions.
This is a prompt to note the fuse rating when replacing fuses. The fuse referenced in the text must be replaced with one having the ratings indicated.
Identifies a protective grounding terminal which must be connected to earth ground prior to making any other equipment connections.
Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal.
Indicates that static sensitive components are present, which may be damaged by electrostatic discharge. Use anti-static procedures, equipment and surfaces during servicing.
Indicates that the equipment has more than one power supply cord, and that all power supply cords must be disconnected before servicing to avoid electric shock.
The presence of this symbol in or on Grass Valley equipment means that it has been tested and certified as complying with applicable Canadian Standard
Association (CSA) regulations and recommendations for USA/Canada.
The presence of this symbol in or on Grass Valley equipment means that it has been tested and certified as complying with applicable Underwriters Laboratory
(UL) regulations and recommendations for USA/Canada.
The presence of this symbol in or on Grass Valley equipment means that it has been tested and certified as complying with applicable Intertek Testing Services regulations and recommendations for USA/Canada.
iii
Notices
The presence of this symbol in or on Grass Valley product means that it complies with all applicable European Union (CE) directives.
The presence of this symbol in or on Grass Valley product means that it complies with safety of laser product applicable standards.
Warnings
A warning indicates a possible hazard to personnel, which may cause injury or death. Observe the following general warnings when using or working on this equipment:
• Appropriately listed/certified mains supply power cords must be used for the connection of the equipment to the mains voltage at either 120 V AC or 240 V AC.
• This product relies on the building's installation for short-circuit (over-current) protection. Ensure that a fuse or circuit breaker for 120 V AC or 240 V AC is used on the phase conductors.
• Any instructions in this manual that require opening the equipment cover or enclosure are for use by qualified service personnel only.
• Do not operate the equipment in wet or damp conditions.
• This equipment is grounded through the grounding conductor of the power cords. To avoid electrical shock, plug the power cords into a properly wired receptacle before connecting the equipment inputs or outputs.
• Route power cords and other cables so they are not likely to be damaged. Properly support heavy cable bundles to avoid connector damage.
• Disconnect power before cleaning the equipment. Do not use liquid or aerosol cleaners; use only a damp cloth.
• Dangerous voltages may exist at several points in this equipment. To avoid injury, do not touch exposed connections and components while power is on.
• High leakage current may be present. Earth connection of product is essential before connecting power.
• Prior to servicing, remove jewelry such as rings, watches, and other metallic objects.
• To avoid fire hazard, use only the fuse type and rating specified in the service instructions for this product, or on the equipment.
• To avoid explosion, do not operate this equipment in an explosive atmosphere.
• Use proper lift points. Do not use door latches to lift or move equipment.
• Avoid mechanical hazards. Allow all rotating devices to come to a stop before servicing.
• Have qualified service personnel perform safety checks after any service.
Cautions
A caution indicates a possible hazard to equipment that could result in equipment damage. Observe the following cautions when operating or working on this equipment:
• This equipment is meant to be installed in a restricted access location.
iv
Kaleido-X16
Hardware Description & Installation Manual
• When installing this equipment, do not attach the power cord to building surfaces.
• Products that have no on/off switch, and use an external power supply must be installed in proximity to a main power outlet that is easily accessible.
• Use the correct voltage setting. If this product lacks auto-ranging power supplies, before applying power ensure that each power supply is set to match the power source.
• Provide proper ventilation. To prevent product overheating, provide equipment ventilation in accordance with the installation instructions.
• Do not operate with suspected equipment failure. If you suspect product damage or equipment failure, have the equipment inspected by qualified service personnel.
• To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Servicing should be done in a static-free environment.
• This unit may have more than one power supply cord. Disconnect all power supply cords before servicing to avoid electric shock.
• Follow static precautions at all times when handling this equipment.
Electrostatic Discharge (ESD) Protection
Electrostatic discharge occurs when electronic components are improperly handled and can result in intermittent failure or complete damage adversely affecting an electrical circuit. When you remove and replace any card from a frame always follow ESD-prevention procedures:
• Ensure that the frame is electrically connected to earth ground through the power cord or any other means if available.
• Wear an ESD wrist strap ensuring that it makes good skin contact. Connect the grounding clip to an unpainted surface of the chassis frame to safely ground unwanted
ESD voltages. If no wrist strap is available, ground yourself by touching the unpainted metal part of the chassis.
• For safety, periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms.
• When temporarily storing a card make sure it is placed in an ESD bag.
• Cards in an earth grounded metal frame or casing do not require any special ESD protection.
Battery Handling
This product includes a backup battery. There is a danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Before disposing of your Grass Valley equipment, please review the Disposal and Recycling Information appendix.
v
Notices
Mesures de sécurité et avis importants
La présente section fournit des consignes de sécurité importantes pour les opérateurs et le personnel de service. Des avertissements ou mises en garde spécifiques figurent dans le manuel, dans les sections où ils s’appliquent. Prenez le temps de bien lire les consignes et assurez-vous de les respecter, en particulier celles qui sont destinées à prévenir les décharges électriques ou les blessures.
Signification des symboles utilisés
Signale la présence d’une tension élevée et dangereuse dans le boîtier de l’équipement ; cette tension peut être suffisante pour constituer un risque de décharge électrique.
Avertit l'utilisateur, l’opérateur ou le technicien de maintenance que des instructions importantes relatives à l'utilisation et à l'entretien se trouvent dans la documentation accompagnant l’équipement.
Invite l'utilisateur, l’opérateur ou le technicien de maintenance à prendre note du calibre du fusible lors du remplacement de ce dernier. Le fusible auquel il est fait référence dans le texte doit être remplacé par un fusible du même calibre.
Identifie une borne de mise à la terre de protection. Il faut relier cette borne à la terre avant d’effectuer toute autre connexion à l’équipement.
Identifie une borne de mise à la terre externe qui peut être connectée en tant que borne de mise à la terre supplémentaire.
Signale la présence de composants sensibles à l’électricité statique et qui sont susceptibles d’être endommagés par une décharge électrostatique. Utilisez des procédures, des équipements et des surfaces antistatiques durant les interventions d’entretien.
Le symbole ci-contre signifie que l’appareil comporte plus d’un cordon d'alimentation et qu’il faut débrancher tous les cordons d'alimentation avant toute opération d’entretien, afin de prévenir les chocs électriques.
La marque C-CSA-US certifie que l’appareil visé a été testé par l'Association canadienne de normalisation (CSA) et reconnu conforme aux exigences applicables en matière de sécurité électrique en vigueur au Canada et aux États-
Unis.
La marque C-UL-US certifie que l’appareil visé a été testé par Underwriters
Laboratory (UL) et reconnu conforme aux exigences applicables en matière de sécurité électrique en vigueur au Canada et aux États-Unis.
vi
Kaleido-X16
Hardware Description & Installation Manual
La marque ETL Listed d’Intertek pour le marché Nord-Américain certifie que l’appareil visé a été testé par Intertek et reconnu conforme aux exigences applicables en matière de sécurité électrique en vigueur au Canada et aux États-
Unis.
Le marquage CE indique que l’appareil visé est conforme aux exigences essentielles des directives applicables de l’Union européenne en matière de sécurité électrique, de compatibilité électromagnétique et de conformité environnementale.
Le symbole ci-contre sur un appareil Grass Valley ou à l’intérieur de l’appareil indique qu’il est conforme aux normes applicables en matière de sécurité laser.
Avertissements
Les avertissements signalent des conditions ou des pratiques susceptibles d’occasionner des blessures graves, voire fatales. Veuillez vous familiariser avec les avertissements d’ordre général ci-dessous :
• Un cordon d’alimentation dûment homologué doit être utilisé pour connecter l’appareil à une tension de secteur de 120 V CA ou 240 V CA.
• La protection de ce produit contre les courts-circuits (surintensités) dépend de l’installation électrique du bâtiment. Assurez-vous qu'un fusible ou un disjoncteur pour
120 V CA ou 240 V CA est utilisé sur les conducteurs de phase.
• Dans le présent manuel, toutes les instructions qui nécessitent d’ouvrir le couvercle de l’équipement sont destinées exclusivement au personnel technique qualifié.
• N’utilisez pas cet appareil dans un environnement humide.
• Cet équipement est mis à la terre par le conducteur de mise à la terre des cordons d’alimentation. Pour éviter les chocs électriques, branchez les cordons d’alimentation sur une prise correctement câblée avant de brancher les entrées et sorties de l’équipement.
• Acheminez les cordons d’alimentation et autres câbles de façon à ce qu’ils ne risquent pas d’être endommagés. Supportez correctement les enroulements de câbles afin de ne pas endommager les connecteurs.
• Coupez l’alimentation avant de nettoyer l’équipement. Ne pas utiliser de nettoyants liquides ou en aérosol. Utilisez uniquement un chiffon humide.
• Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement.
Pour éviter toute blessure, ne touchez pas aux connexions ou aux composants exposés lorsque l’appareil est sous tension.
• Avant de procéder à toute opération d’entretien ou de dépannage, enlevez tous vos bijoux (notamment vos bagues, votre montre et autres objets métalliques).
• Pour éviter tout risque d’incendie, utilisez uniquement les fusibles du type et du calibre indiqués sur l’équipement ou dans la documentation qui l’accompagne.
• Ne pas utiliser cet appareil dans une atmosphère explosive.
• Présence possible de courants de fuite. Un raccordement à la masse est indispensable avant la mise sous tension.
vii
Notices
• Après tout travail d’entretien ou de réparation, faites effectuer des contrôles de sécurité par le personnel technique qualifié.
Mises en garde
Les mises en garde signalent des conditions ou des pratiques susceptibles d’endommager l’équipement. Veuillez vous familiariser avec les mises en garde cidessous :
• L’appareil est conçu pour être installé dans un endroit à accès restreint.
• Au moment d’installer l’équipement, ne fixez pas les cordons d’alimentation aux surfaces intérieures de l’édifice.
• Les produits qui n'ont pas d’interrupteur marche-arrêt et qui disposent d’une source d’alimentation externe doivent être installés à proximité d'une prise de courant facile d’accès.
• Si l’équipement n’est pas pourvu d’un modules d’alimentation auto-adaptables, vérifiez la configuration de chacun des modules d'alimentation avant de les mettre sous tension.
• Assurez une ventilation adéquate. Pour éviter toute surchauffe du produit, assurez une ventilation de l’équipement conformément aux instructions d’installation.
• N’utilisez pas l’équipement si vous suspectez un dysfonctionnement du produit. Faitesle inspecter par un technicien qualifié.
• Pour réduire le risque de choc électrique, n'effectuez pas de réparations autres que celles qui sont décrites dans le présent manuel, sauf si vous êtes qualifié pour le faire.
Confiez les réparations à un technicien qualifié. La maintenance doit se réaliser dans un milieu libre d’électricité statique.
• L’appareil peut comporter plus d’un cordon d'alimentation. Afin de prévenir les chocs
électriques, débrancher tous les cordons d'alimentation avant toute opération d’entretien.
• Veillez à toujours prendre les mesures de protection antistatique appropriées quand vous manipulez l’équipement.
Protection contre les décharges électrostatiques (DES)
Une décharge électrostatique peut se produire lorsque des composants
électroniques ne sont pas manipulés de manière adéquate, ce qui peut entraîner des défaillances intermittentes ou endommager irrémédiablement un circuit
électrique. Au moment de remplacer une carte dans un châssis, prenez toujours les mesures de protection antistatique appropriées :
• Assurez-vous que le châssis est relié électriquement à la terre par le cordon d'alimentation ou tout autre moyen disponible.
• Portez un bracelet antistatique et assurez-vous qu'il est bien en contact avec la peau.
Connectez la pince de masse à une surface non peinte du châssis pour détourner à la terre toute tension électrostatique indésirable. En l’absence de bracelet antistatique, déchargez l’électricité statique de votre corps en touchant une surface métallique non
peinte du châssis.
viii
Kaleido-X16
Hardware Description & Installation Manual
• Pour plus de sécurité, vérifiez périodiquement la valeur de résistance du bracelet antistatique. Elle doit se situer entre 1 et 10 mégohms.
• Si vous devez mettre une carte de côté, assurez-vous de la ranger dans un sac protecteur antistatique.
• Les cartes qui sont reliées à un châssis ou boîtier métallique mis à la terre ne nécessitent pas de protection antistatique spéciale.
Remplacement et élimination des piles
L’appareil renferme une pile. Pour réduire le risque d’explosion, vérifiez la polarité et ne remplacez la pile que par une pile du même type, recommandée par le fabricant.
Mettez les piles usagées au rebut conformément aux directives du fabricant. Avant de vous défaire de l’équipement, assurez-vous d’avoir lu l’appendice Disposal and Recycling
Information.
Recycling
Visit www.grassvalley.com for recycling information.
Certification and Compliance
Safety Compliance
Th is equipment complies with the requirements of the following standards for safety of information technology equipment:
– CSA-C22.2 No. 60950-1-07 (2 nd
Edition)
– UL 60950-1 (2 nd
Edition)
– EN 60950-1:2006 ITE
– IEC 60950-1:2005 (2 nd
Edition)
The power cords supplied with this equipment meet the appropriate national standards for the country of destination.
Electromagnetic Compatibility
This equipment has been tested for verification of compliance with FCC Part 15,
Subpart B requirements for class A digital devices.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ix
Notices
This equipment has been tested and found to comply with the requirements of the
EMC directive 2004/108/EC:
• EN 55022 Class A Radiated and conducted emissions
• EN 61000-3-2 Limits for harmonic current emissions
• EN 61000-3-3 Limitation of voltage fluctuations and flicker
• EN 61000-4-2 Electrostatic discharge immunity
• EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity
• EN 61000-4-4 Electrical fast transient immunity
• EN 61000-4-5 Surge transient immunity
• EN 61000-4-6 Conducted disturbances immunity
• EN 61000-4-8 Power frequency magnetic field immunity
• EN 61000-4-11 Voltage dips, short interruptions and voltage variations immunity x
Table of Contents
1 Kaleido-X16 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Appendix: Disposal and Recycling Information . . . . . . . . . . . . . 31
xi
Kaleido-X16 Installation
The Kaleido-X16 is a 1RU, multi-image display processor with high image quality and a rich feature set. This chapter contains physical descriptions, installation instructions and connection information for the Kaleido-X16 frame.
Summary
Introduction
The Kaleido-X16 system is a cost-effective multi-image processor. It can accommodate smaller systems or scale up to production systems, where smaller building blocks with fewer input counts per display are desirable. Each chassis can display up to 16 auto-sensing
HD, SD, or Analog inputs that can be displayed across two high resolution outputs at multiple sizes.
Features
Small form factor 1RU
Expandable
Unmatched flexibility
Expandable multi-room architecture, based on a chassis with 16 inputs, and 2 independent multi-image display outputs
Any source can be repeated to any position, to any display, at any size, at any resolution, without blocking or grouping restrictions
1
Kaleido-X16 Installation
Port Availability
Kaleido-X16 as a router
The Kaleido-X16 can behave as a router, with 16 input channels as sources and the two RT OUT outputs as destinations
Superior display Highest quality multi-image output without compression, with superior on-screen graphics, for the most critical live monitoring applications
128 audio channels
Unprecedented audio performance with the ability to monitor up to
128 channels of audio, including embedded, discrete analog, discrete AES from ABT
DVI inputs DVI inputs (one per output head) mappable in the background of each output without the need for scaling
Two-room layouts Intuitive layout editor software allows rapid creation of two-room layouts, which can be recalled quickly from networked remote control panels
Highly robust Highly robust design, with multiple points of redundancy, and no single point of failure for reliable 24/7 operation
Port Availability
The Kaleido-X16 offers a wide variety of ports for incoming and outgoing signals. However, with a view towards future expansion, there are ports whose connections exist but that are currently not fully supported. The following ports on the Kaleido-X16 are not yet supported:
• OPTION streaming output connector
• PC In analog audio input ports at the Audio I/O connector
Overview of the Kaleido-X16 System
The following diagram shows a basic Kaleido-X16 system configuration, with a single
Kaleido-X16 feeding 2 monitor wall displays. The Kaleido-RCP2 would be located on the production desk, while the Client PC could be anywhere with Internet access to the network.
The diagram below shows a Kaleido-X16 system with its inputs and outputs. Examples of the various external devices that connect to the Kaleido-X16 are also shown.
2
3
Kaleido-X16
Hardware Description & Installation Manual
The Kaleido-X16 system is available in two model types: a single-head model ( Kaleido-X16 -S) and a dual-head model ( Kaleido-X16 -D). Throughout this manual, Kaleido-X16 refers to both models unless it is necessary to distinguish the single-head model from the dual-head model.
Kaleido-X16-D
There are two heads (Head 1 and Head 2) on the dual-head Kaleido-X16 ( Kaleido-X16 -D). The
Input and Output connections are as follows.
Connector Number of connectors on Head 1 Number of connectors on Head 2
MV OUT 1 1
SDI OUT
DVI IN
1
1
1
1
The rear connector panel for this model is displayed, below:
In addition to the difference in the number of output heads, the Audio I/O TBA pinout is different between the two models (see
Audio I/O TBA , on page 14 for details).
Kaleido-X16-S
There is one head (Head 1) on the single-head Kaleido-X16 ( Kaleido-X16 -S). The Input and
Output connections are as follows.
Connector Number of connectors on Head 1
MV OUT
SDI OUT
DVI IN
1
1
1
The rear connector panel for this model is displayed, below:
No Head 2 connectors
(DVI IN2, SDI OUT2, MV OUT2)
In addition to the difference in the number of heads, the Audio I/O TBA pinout is different
between the two models (see Audio I/O TBA , on page 14 for details).
4
Kaleido-X16 Installation
Mechanical Installation
Mechanical Installation
Unpacking
Make sure the following items have been shipped with your Kaleido-X16 . If any of these are missing, contact your distributor or Grass Valley.
• Kaleido-X16 unit with one or two power supplies pre-installed (second power supply optional)
• Two support brackets
• One AC power cord per power supply
• DVD including manuals, software and release notes
• One mouse
• Four serial port adapters (one with straight wiring and one with crossover wiring for each of the two RS-422 ports on your multiviewer):
Part number Adapter cabling RS-422 pinout at the DE-9P connector
1737-3000-102 Straight
1792-3700-100 Crossover
Controller (SMPTE master) mode
Tributary (SMPTE slave) mode
Notes
• The Kaleido-RCP2 unit is optional and is not included in the standard
Kaleido-X16 package. Refer to the Kaleido-RCP2 Guide to Installation and
Operation (available on the DVD that shipped with your system) for more information.
• The standard Kaleido-X16 comes with one PSU. A redundant, second PSU is optional.
Mounting the Kaleido-X16 in a Rack
To mount the Kaleido-X16 in a standard 19-inch rack
1 Install both support brackets at the back of the rack by using suitable screws and washers (not included), so that the bottom of the Kaleido-X16 frame will be supported by the brackets.
5
Kaleido-X16
Hardware Description & Installation Manual
2 Insert the Kaleido-X16 frame at the designated location within the rack, and secure the front of the frame to the rack by using suitable screws and washers (not included).
IMPORTANT
Mobile Installation
If you are deploying your Kaleido-X16 in a mobile unit, it is your responsibility to make sure the back of the multiviewer is securely attached to the rack. For instance you may install a blank panel at the back of the rack, so that it meets the top of the frame, to prevent the frame from bouncing away from the support brackets.
Ventilation
For proper ventilation, make sure the front and side panel air vents are not blocked and the air filter is clean.
Note: The optional Kaleido-RCP2 may also be installed in a rack, by using the KRCP-RK2 mounting kit.
Frame and Electrical Installation
The Kaleido-X16 multiviewer is a self-contained unit consisting of a frame, redundant power supplies, and various input and output cards. The monitor wall displays and external control devices complete the system.
Frame
The Kaleido-X16 frame is 1 RU high. Input and output connectors are mounted on a connector panel on the rear of the frame. The redundant power supply is installed in the front of the frame. The front cover can be removed to give access to the PSUs,
CompactFlash card, USB connector, and basic LEDs.
The Kaleido-X16 frame incorporates the following key elements:
• A rack-mountable mechanical framework (for mounting into a 19-inch EIA rack)
• A removable door to cover and protect the front of the frame
• An optional redundant power supply
• Ventilation
Front view of the Kaleido-X16 frame (PSUs installed; front cover removed)
Kaleido-X16 Installation
Frame
CPU Reference Input General Status
6
LTC
CF Activity Video Inputs DVI Inputs
LTC
SDTI Severity
LEDs on the front of the frame (behind the cover)
The LEDs on the front of the frame (behind the cover) indicate the following conditions depending on their color and whether they are blinking or not:
LED Status
LED Green
CPU Normal operation
CPF Activity N/A
Video Inputs Inputs are locked
DVI Inputs Inputs are locked
LTC valid
Blinking green
Application booting
Activity
N/A
Red
Error
N/A
N/A
Blinking red Yellow
Live Update OS Booting N/A
N/A N/A
Inputs are unlocked, or no input
ERROR ON
SIGNAL
Inputs are unlocked, or no input
ERROR ON
SIGNAL
No signal N/A
N/A
N/A
N/A
N/A
Blinking yellow
N/A
N/A
N/A
N/A
Off
Front cover is closed
No Activity
Front cover is closed
Front cover is closed
Front cover is closed
Front cover is closed
Ref. Input
SDTI
Input is locked
Inputs are locked
N/A
N/A
Gen. Status System OK Intrusive selfdiagnostic finished
Severity Boot OK Booting
Input is unlocked, or no input
ERROR ON
SIGNAL
Inputs are unlocked, or no input, or no SDTI signal
ERROR ON
SIGNAL
Configuratio n Failed,
Safe Mode
Boot error,
Need liveupdate
Firmware
Upgrading
Fatal error,
CALL TECH
SUPPORT
N/A
N/A
Boot up
Diagnostic
(Verbose switch on)
N/A
N/A
N/A
Firmware error
N/A
Front cover is closed
Front cover is closed
No power
Kaleido-X16
Hardware Description & Installation Manual
Monitoring the Temperature of the Kaleido-X16
For optimal performance, it is strongly recommended that you operate the Kaleido-X16 multiviewer in an environment with an ambient temperature between 0 °C and 40 °C.
IMPORTANT
When measuring the ambient room temperature, take your readings from directly in front of the Kaleido-X16 frame.
There are two factors that could influence airflow inside the frame: altitude and airflow obstruction on the sides of the unit.
Power Supplies
Power supply for the Kaleido-X16 frame
The Kaleido-X16 frame is powered by dual redundant, current-sharing power supply units
(PSUs). The PSUs are installed and removed from the front of the frame and are hotswappable, so that a defective supply may be replaced without removing the Kaleido-X16 frame from service. When facing the front of the frame, the PSU on the left side is referred to as PSU A and the PSU on the right side is PSU B.
IMPORTANT
If your frame has only one PSU, it must be installed in Slot A (left side of frame)
There are two power supplies: an operational PSU and a redundant PSU. The system operates with a single PSU. If you choose to have only one PSU installed in your Kaleido-X16 frame, you should do the following:
• Clear the PSU B Installed check box for this Kaleido-X16 frame in XAdmin
(see the “Configuring Power Supply Redundancy on the Kaleido-X16” section in the Getting Started chapter of the Kaleido-X User’s Manual).
• Install the single PSU (PSU A) in Slot A (the left side of the frame when
facing the front of the frame) (see Installing a Power Supply , on page 8).
Access the power supplies by removing the front cover of the frame. Viewed from the front of the frame, the PSUs are located on the left-hand and right-hand sides of the frame:
7
Kaleido-X16 Installation
Power Supplies
PSU A removed from Slot A
PSU slot locations
Slot A Slot B
8
Two PSUs installed in a frame; front cover removed
Removing a Power Supply
To remove a power supply
1 Open the front cover of the frame and locate the power supply (PSU) you would like to remove (either the left or the right side).
2 Pull on the handle on the right side of the PSU and pull the PSU out of the frame.
Installing a Power Supply
To install a power supply
1 Position the power supply (PSU) in front of an empty power supply slot in front of the frame, with the connector end towards the frame and the PSU handle on the right side.
2 Slide the PSU into the empty slot, moving it gently until it contacts the sockets at the rear of the slot.
3 Push firmly but gently on the PSU faceplate until the PSU’s connectors have mated with the frame's sockets, and the PSU will go in no further.
Powering up the Kaleido-X16
Separate AC power sockets serve the two power supplies. On the rear of the frame, connect both power sockets of the Kaleido-X16 to an appropriate power source using the supplied power cords.
As seen from the rear of the frame:
• The left power socket is for PSU B.
• The right power socket is for PSU A.
Kaleido-X16
Hardware Description & Installation Manual
Power socket for PSU B Power socket for PSU A
IMPORTANT
• A Kaleido-X16 multiviewer can draw 4.0 amps of current. Ensure that the circuit to which the frame is connected can handle that load, and that of any other connected devices.
• If you only have one PSU, make sure you plug your power cable into the power connector on the right side of the rear connector panel (as you face the rear of the frame). This should be on the same side of the frame as the one PSU you have installed. If you do not do this, your system cannot draw power.
• If you have two PSUs, make sure you plug in both power cables into both power connectors of the rear connector panel. If you do not do this your system cannot have PSU redundancy.
To power up the Kaleido-X16
1 Plug the power cord(s) from the Kaleido-X16 into a grounded power outlet.
2 Push the power button at the front of the frame (behind the front cover).
Power button
The startup sequence takes a couple of minutes, during which time some video may appear on the displays. The startup is completed when the CPU LED is solid green.
Ventilation
The Kaleido-X16 multiviewer is cooled by ventilation intakes located on the front of the frame. Fans are located in key positions within the frame:
9
Kaleido-X16 Installation
Ventilation
10
Air flow through the Kaleido-X16 frame
Frame Cooling Fans
Air intake for the multiviewer is handled by six fans located near the front of the frame and two heat sinks near the rear of the frame. The fans draw air into the frame through a grille and filter in the front cover. The heat sinks help to exhaust air out through grates on either side (see diagram, above).
IMPORTANT
The Kaleido-X16 multiviewer requires a constant flow of cooling air during operation. DO NOT OPERATE THE UNIT IF THESE FANS ARE NOT WORKING. If a fan is not working contact your next level of support.
Power Supply Cooling Fan
Each PSU has one fan located on its front. Each PSU draws air through the frame’s front grille, through the PSU, then out to the closest rear fan to be exhausted out the side of the frame (see diagrams, above and below):
PSU fan on front of PSU A
Air Filter
Cooling air drawn into the Kaleido-X16 frame by the ventilating fans passes through a filter located behind a grille in the front cover of the frame.
For more information about cleaning the air filter, see Cleaning the Air Filter , on page 21.
Kaleido-X16
Hardware Description & Installation Manual
CompactFlash
In order to boot the CPU, you must ensure the appropriate CompactFlash (CF) card is properly inserted in the CF slot (accessible from the front of the Kaleido-X16 frame). The CF card contains the operating system required for a system boot.
Signalling
CF slot on front of Kaleido-X16 frame
For more information about starting the Kaleido-X16, see the Setting up the Kaleido-X16 chapter in the Kaleido-X16 Quick Start Guide.
IMPORTANT
The Kaleido-X16-D model supports two Heads while the Kaleido-X16-S supports one Head. For details about the difference in connector support on the two models, see
Kaleido-X16-D , on page 3 and Kaleido-X16-S , on page 3.
Connector label Connector type Function
DVI IN1-2
INPUTS 1-16
DVI
BNC
DVI input signal that can be used as a background in the monitor wall display in place of the internally-generated background.
HD/SD-SDI or composite video inputs 1 to 16.
MV OUT 1-2
SDI OUT 1-2
REF
HDMI
BNC
BNC
HDMI output including embedded audio for each head.
Serial digital HD output signal for monitoring purposes.
Reference signal to genlock the multiviewer to the local plant. Supported Reference formats:
• SMPTE ST 170
• SMPTE ST 318
• ITU 624-4
• BUT 470-6
• PAL and NTSC composite sync
• SMPTE ST 274
• SMPTE ST 296
• SMPTE ST 240
LTC 1-2
GPI 1-44
RT OUT 1-2
BNC Time code inputs.
DB-44 (female) GPI input/output (unidirectional) connections.
BNC Supports 3Gbps-SDI, HD-SDI, and SD-SDI router output signals.
11
Kaleido-X16 Installation
Inputs
Connector label Connector type Function
AUDIO I/O
SDTI
HD-26 (female)
BNC
Supports two AES3 audio outputs or two analog audio outputs for monitoring.
Multiplexed audio from an external audio box (Audio
Bridge Terminal).
ETHERNET
USB
RJ-45
USB
100 Base-T Ethernet connection.
Connect a mouse, keyboard, or USB flash memory for software upgrade or data backup.
Note: There are three USB ports, one on the front of the frame (behind the front cover) and two on the rear connector panel.
RS-422 RJ-45 (see
Connect to an RS-422 (SMPTE ST 207, EBU-3245) or RS-
485 device or network.
Inputs
Video Signals
The 16 BNC Input connectors located on the Kaleido-X16 frame’s rear connector panel
BNC connectors (16) for SD-SDI, HD-SDI,
3Gbps-SDI, and Analog Composite Inputs
Graphic Signals
The Kaleido-X16-D supports two digital DVI inputs, one for each of two heads (the
Kaleido-X16-S supports a single DVI input). The DVI IN connectors on the rear panel are female, dual-link DVI-I universal connectors. The supported signal and cabling for this connection is single-link DVI-D (see
DVI Graphic Inputs , on page 24 for specification
details).
Note: The two DVI inputs cannot be crossed nor combined. That is, DVI IN 1 must output on Head 1, and DVI IN 2 must output on Head 2.
DVI-D In1 DVI-D In2
12
Kaleido-X16
Hardware Description & Installation Manual
Mosaic Outputs
HDMI Outputs
for the multiviewer output, which carries audio and video, and can support resolutions up to 1920 × 1200.
MV OUT 1/DVI OUT 1 MV OUT 2/DVI OUT 2
Note: To use an HDMI output connection as a DVI output, use an HDMI cable with an HDMI-to-DVI adapter at one end. Alternatively, use an HDMIto-DVI cable.
HD-SDI Monitoring Outputs
IMPORTANT
Audio monitoring at the HD-SDI outputs is supported on recent hardware only.
Support for audio monitoring at the HD-SDI outputs requires version 5.30
(or later) of the Kaleido-X Software, and recent hardware. In the XAdmin
Status and Options page, under SYSTEM, the value indicated for the Card
revision attribute must be 0x4 or more.
There are two HD-SDI monitoring outputs: one for each head (see HD-SDI Monitoring
Outputs , on page 26 for specification details).
BNC connector for
Mosaic SDI OUT 1
BNC connector for
Mosaic SDI OUT 2
External Reference
The external reference (REF) input signal allows the Kaleido-X16 to genlock to the local plant.
BNC connector for
External Reference
13
Kaleido-X16 Installation
Router Outputs
Router Outputs
The Kaleido-X16 can be configured as a router. In this configuration, up to two Kaleido-X16 channels are considered as sources, and the destinations are the two RT OUT ports on the rear connector panel:
BNC connectors for router outputs
For more information about Router Output specifications, see
For more information about Routers and the Kaleido-X16, see the Routers chapter of the
Kaleido-X User’s Manual.
Audio I/O
The Kaleido-X16 supports audio monitoring through its HD-26 connector. The supported formats are AES3 digital audio, and analog audio. In addition, the Kaleido-X16 supports audio monitoring through the SDTI input port from an audio bridge terminal (ABT).
BNC connector for SDTI input
BNC connector for
External Reference
HD-26 audio I/O connector for AES, analog
Audio I/O TBA
To facilitate cabling through the HD-26 connector, a terminal block adapter (TBA) is available separately (order code NSH26M).
14
Audio I/O Terminal
Block Adapter
Audio I/O Terminal Block Adapter installed in rear connector panel
The pinout of the Audio I/O terminal block adapter (TBA) depends on whether you have a single-head or dual-head Kaleido-X16 model.
15
Kaleido-X16
Hardware Description & Installation Manual
Audio I/O TBA Pinout on the Kaleido-X16-D
The Audio I/O TBA pinout on the Kaleido-X16-D is as follows:
Bottom row
19 GND
20 GND
21 GND
22 GND
23 GND
24 GND
25 GND
26 GND
Center row
10 AES Out 1 (+)
11 AES Out 2 (+)
12 GND
13 Analog Left Out 1 (+)
14 Analog Right Out 1 (+)
15 Analog Left Out 2 (+)
16 Analog Right Out 2 (+)
17 PC In 1 Left (not supported)
18 PC In 2 Left (not supported)
Top row
1 AES Out 1 (-)
2 AES Out 2 (-)
3 GND
4 Analog Left Out 1 (-)
5 Analog Right Out 1 (-)
6 Analog Left Out 2 (-)
7 Analog Right Out 2 (-)
8 PC In 1 Right (not supported)
9 PC In 2 Right (not supported)
Audio I/O TBA Pinout on the Kaleido-X16-S
The Audio I/O TBA pinout on the Kaleido-X16-S is as follows:
Bottom row
19 GND
20 GND
21 GND
22 GND
23 GND
24 GND
25 GND
26 GND
Center row
10 AES 1 (+)
11 NC
12 GND
13 Analog Left Out 1 (+)
14 Analog Right Out 1 (+)
15 NC
16 NC
17 PC In 1 Left (not supported)
18 NC
Top row
1 AES 1 (-)
2 NC
3 GND
4 Analog Left Out 1 (-)
5 Analog Right Out 1 (-)
6 NC
7 NC
8 PC In 1 Right (not supported)
9 NC
For more information about:
• SDTI audio specifications, see
SDTI Audio Input , on page 28.
• analog audio specifications, see Analog Audio Output , on page 28.
• AES output specifications, see AES Outputs , on page 28.
• triggering audio monitoring, see “Triggering Audio Monitoring” in the Operation of the
Monitor Wall chapter of the Kaleido-X User’s Manual.
• calibrating audio monitoring delay, see “Calibrating the Audio Monitoring Delay” in the
Calibrating the Kaleido-X chapter of the Kaleido-X User’s Manual.
• calibrating audio monitoring color, see “Calibrating the Audio Monitoring Color” in the
Calibrating the Kaleido-X chapter of the Kaleido-X User’s Manual.
Kaleido-X16 Installation
Control
Control
The connectors located in the middle of the rear connector panel (the yellow and orange color-coded area) are Control connectors.
BNC connectors for LTC inputs
DB-44 connector for GPI I/O
RJ-45 Ethernet connector
USB connectors (2)
RJ-45 connectors
(2) for RS-422 serial connections
Linear Time Code (LTC)
The Kaleido-X16 supports two linear time code (LTC) inputs over BNC connectors. The format is SMPTE ST 12 unbalanced (see
Time Code Inputs (LTC) , on page 28 for specification
details).
GPI I/O
The Kaleido-X16 supports status monitoring, genlock and GPI interfacing. The rear connector panel houses all input and output connectors associated with GPI I/O. The
Kaleido-X16 supports 32 GPI inputs and 4 GPI outputs. The GPI connector type is a DB-44
(female on the connector panel; male on the cable):
Pin 15 Pin 1
Pin 44 Pin 31
Pin 30 Pin 16
There are 44 GPI connector pins (40 not including GND) whose functions are as follows:
• 4 Ground (GND) pins
• 32 GPI Input pins
• 4 GPI Output Emitter pins (designated in the table, below, as “N”)
• 4 GPI Output Collector pins (designated in the table, below, as “P”)
The exact pinout for the GPI connector is as follows:
Bottom row
Pin # Description
31
32
GND
GPI Output N 2
33
34
GPI Output P 3
GPI Input 21
Middle row
Pin # Description
16
17
GPI Output N 1
GPI Output P 2
18
19
GPI Output N 4
GPI Input 22
3
4
1
2
Top row
Pin # Description
GPI Output P 1
GPI Output N 3
GPI Output P 4
GPI Input 23
16
17
Kaleido-X16
Hardware Description & Installation Manual
40
41
42
43
44
36
37
38
39
Bottom row
Pin # Description
35 GND
GPI Input 26
GPI Input 29
GPI Input 20
GPI Input 16
GPI Input 14
GND
GPI Input 9
GPI Input 6
GPI Input 3
25
26
27
28
21
22
23
24
29
30
Middle row
Pin # Description
20 GPI Input 24
GPI Input 27
GPI Input 30
GPI Input 32
GPI Input 19
GPI Input 17
GPI Input 13
GPI Input 11
GPI Input 8
GPI Input 5
GPI Input 2
10
11
12
13
8
9
6
7
14
15
Top row
Pin # Description
5 GPI Input 25
GPI Input 28
GPI Input 31
GPI Input 18
GPI Input 15
GPI Input 12
GPI Input 10
GPI Input 7
GPI Input 4
GPI Input 1
GND
GPI Circuits
The individual GPI contacts are reconfigurable as either inputs or outputs. For interfacing purposes, the input and output circuit configurations are as shown in the following diagrams:
GPI configured as INPUT GPI configured as OUTPUT
You should ensure your GPI physical connections are well established. In the following example, the goal is to trigger a relay and light up a light.
CAUTION
In the example, below, make sure your P and N connections are in the proper polarity otherwise your GPI output will always be in the ON state.
Kaleido-X16 Installation
Control
To facilitate cabling of the GPI inputs and outputs, a terminal block adapter is available separately (order code KXA-TBA-44). The GPI Terminal Block Adapter accommodates up to
44 terminal block connections using positive and negative terminal connections. Each column on the terminal block has 6 positive and 6 negative terminal connections that correspond to each pin position. Negative pins (labelled with an N) on the Terminal Block
Adapter are not used as connections. Positive pins (labelled with a P) and Ground pins
(labelled with a GND) correspond to GPI input connections:
GPI Terminal Block Adapter
GPI Terminal Block Adapter installed in rear connector panel
18
Kaleido-X16
Hardware Description & Installation Manual
19
Kaleido-X16 GPI Terminal Block Adapter pinout
For more information about:
• GPI specifications, see
GPI INPUT (up to 32) and GPI OUTPUT (up to 4) , on page 29.
• triggering GPI output events, see “Triggering GPI Output Events” in the Operation of the
Monitor Wall chapter of the Kaleido-X User’s Manual.
• calibrating GPI lines, see “Calibrating GPI Lines” in the Calibrating the Kaleido-X chapter of the Kaleido-X User’s Manual.
Ethernet
The Kaleido-X16 supports one Ethernet connection through an RJ-45 connector (see
Ethernet , on page 29 for specification details).
USB
The Kaleido-X16 has three USB 1.0 connectors (see
USB , on page 29 for specification
details). Connect a mouse, keyboard, or USB flash memory for a software upgrade or data backup. Two connectors are on the rear connector panel, and one is on the front of the frame behind the front cover.
Two USB connectors
Two USB connectors on the rear panel
Kaleido-X16 Installation
Control
USB (1) connector on front of Kaleido-X16
20
One USB connector on the front of the frame
RS-422
The Kaleido-X16 supports two RS-422 serial inputs over RJ-45 connectors. These inputs allow the Kaleido-X16 to connect to external serial devices such as a router, production switcher, or router controller.
Note: The Kaleido-X16’s two RS-422 ports each have an RJ-45 connector in order to preserve space on a busy panel. The RS-422 interface specifies a
DE-9 connector, so if you are using this interface, you will require a
DE-9-to-RJ-45 adapter. Grass Valley supplies two adapter models, correctly wired for this application: a straight adapter (part no. 1737-3000-102), and a crossover adapter (part no. 1792-3700-100).
The pinout for the RS-422 signals on the Kaleido-X16’s RJ-45 connectors, and the wiring diagrams for the appropriate adapters, are shown here:
Pinout of each RS-422 port’s RJ-45 connector on the multiviewer
RJ-45
Pinout of straight adapter (Grass
DE-9 male DE-9 female
Pinout of RS-422
Valley part no. 1737-3000-102) connector on SMPTE
slave device
Standard wiring between multiviewer and devices wired to SMPTE “slave” specification (e.g. most routers, Ross Synergy switchers, Nevion ETH-CON)
Kaleido-X16
Hardware Description & Installation Manual
Pinout of each RS-422 port’s RJ-45 connector on the multiviewer
RJ-45
Pinout of crossover adapter (Grass
DE-9 male DE-9 female
Pinout of RS-422
Valley part no. 1792-3700-100) connector on SMPTE
master device
Standard wiring between multiviewer and devices wired to SMPTE “master” specification (e.g. Philips
Jupiter router control system, Miranda Presmaster PCS)
Note: The two RS-422 ports on the Kaleido-X16 side have no ground pin.
Using the appropriate DE-9S-to-RJ-45 adapter, an external device should be able to communicate with a Kaleido-X16 despite the lack of a ground.
For more information about RS-422 specifications, see RS-422 , on page 29. For more
information about RS-422 serial connections, see “Serial Connections” in the “Routers” chapter of the Kaleido-X User’s Manual.
Maintenance
Cleaning the Air Filter
Occasionally, the air filter has to be cleaned in order to maintain proper ventilation. The air filter is located in the front cover of the Kaleido-X16 frame. The filter may be cleaned without removing it from the cover.
To clean the air filter
1 Carefully remove the cover from the frame.
IMPORTANT
Risk of damage to CompactFlash card
Be careful not to damage the CompactFlash card as you remove the front cover of the frame. Lift the cover directly away from the frame (i.e.: not up or down).
2 Place the cover flat on a work surface with the inside facing up.
3 Using a vacuum cleaner with a brush nozzle to prevent scratching, vacuum the dust from the inner side of the cover.
4 Turn the cover over and vacuum the outer side of it.
5 Reinstall the cover onto the frame.
21
Kaleido-X16 Installation
Replacing a Defective Power Supply
Replacing a Defective Power Supply
In the event of a power supply failure, the unit will switch to the redundant power supply for its power source. If a PSU’s LED is not green, you must replace the unit.
For more information about removing and reinstalling a power supply, see
22
Specifications
This chapter lists equipment specifications for the Kaleido-X16 multiviewer.
Inputs
Video Signal Inputs
The Kaleido-X16 frame supports 16 signal inputs. The supported input types include
Composite, SD/SDI, HD-SDI, and 3Gbps (auto-detected). The processing delay is two fields if the video inputs are genlocked, and two or three fields if the video inputs are not genlocked. Signal inputs require BNC connectors.
Composite Inputs
Signal
Return loss
Quantization
NTSC (SMPTE ST 170), NTSC-J, PAL-BGDHI, PAL-N, PAL-M, SECAM
> 30 dB up to 5.75 MHz
8 bits
SD-SDI Inputs
Signal
Formats
Audio
Cable length
Return loss
Jitter
HD-SDI Inputs
Signal
4:2:2 SMPTE ST 259-C (270 Mbps)
525 and 625
SMPTE ST 274:1994
225 m (738 ft) (Belden 1694A)
>15 dB up to 270 MHz
< 0.2 UI
4:2:2 SMPTE ST 292-C (1.5 Gbps)
23
Specifications
DVI Graphic Inputs
HD-SDI Inputs (continued)
Formats 720p24, 720p25, 720p29.97, 720p50, 720p59.94
1080i50, 1080i59.94
1080PsF23.98, 1080PsF24, 1080PsF25, 1080PsF29.97
1080p23.98, 1080p24, 1080p25, 1080p29.97
Note: The Kaleido-X software does not distinguish between
1080PsF25 and 1080i50, and neither between 1080PsF29.97 and
1080i59.94. Both 1080PsF25 and 1080i50 are reported as 1080i50, and both 1080PsF29.97 and 1080i59.94 are reported as
1080i59.94, on the monitor wall and in XAdmin’s Status and
Options page.
Audio
Return loss
Jitter
Cable length
SMPTE ST 299-1
>15 dB up to 1.485 GHz
< 0.2 UI
100 m (328 ft) (Belden 1694A)
3Gbps Inputs
Signal
Formats
Audio
Return loss
Jitter
Cable length
4:2:2 SMPTE ST 424:2006 (2.97/1.001 Gbps)
1080p50
1080p59.94
SMPTE ST 299-1
> 15 dB up to 1.485 GHz
> 10dB up to 2.97GHzß
< 0.2 UI
100 m (328 ft) (Belden 1694A)
Graphics converted to HD-SDI from KXI-DVI-Bridge
Signal
Formats
Cable length
SMPTE ST 292-C (1.485, 1.485/1.001 Gbps)
1024 × 768 @ 60 (XGA)
1280 × 1024 @ 60 (SXGA)
1366 × 768 or 1368 × 768 @ 60 (WXGA)
1680 × 1050 @ 60 (WSXGA+)
1600 × 1200 @ 60 (UXGA)
100 m (328 ft) (Belden 1694A)
DVI Graphic Inputs
The Kaleido-X16 supports two DVI inputs, one for each of two output heads.
Signal
Resolution
DVI-D (single link)
From 1024 × 768 to 1920 × 1200 NI
24
Kaleido-X16
Hardware Description & Installation Manual
H frequency
Refresh rate
Cable length
Connector
37 kHz to 96 kHz
50/59.94 Hz
3.6 m (12 ft) with Altinex CB4012DV
DVI-I (dual link)
Outputs
Mosaic Outputs
The Kaleido-X16 frame supports two HDMI outputs.
HDMI Outputs
Signal
Resolution
H frequency
Refresh rate
Cable length
Connector
Supported cable types
DVI-D
From 1024 × 768 to 1920 × 1200 NI
37 kHz to 96 kHz
50/59.94 Hz
5 m (15 ft)
1
HDMI
HDMI to HDMI, or HDMI to DVI-D
1.Depending on the selected output resolution, on your display monitor’s tolerance, and on the quality of the HDMI cable itself, a longer cable could be used, as long as the signal integrity is maintained between the multiviewer, and the display monitor. For example, with a 1080p output resolution, longer high-speed HDMI cables may require an HDMI booster.
The following table lists some (but not all) output formats supported on the HDMI connection.
Resolution
1024 × 768
1280 × 720
1280 × 768
1280 × 1024
1280 × 1024
1360 × 768
1480 × 1200
1600 × 1200
1920 × 1080
1920 × 1200
Format name Refresh rates (Hz)
XGA 50.00, 59.94
Margay
WXGA
50.00, 59.94
50.00, 59.94
SXGA
Barco
NEC
Christie
50.00, 59.94
59.94
50.00, 59.94
50.00, 59.94
UXGA
Baycat
WUXGA
50.00, 59.94
50.00, 59.94
50.00, 59.94
25
Specifications
Mosaic Outputs
Note: Users can customize their own timing rates through the XEdit software for resolutions ranging from 1024 × 768 up to 1920 × 1200 pixels.
The Kaleido-X16 frame supports two 3G/HD-SDI monitoring outputs (with embedded audio).
HD-SDI Monitoring Outputs
Signal
Formats
Audio
Cable length
Jitter
Connectors
4:2:2 SMPTE ST 292-C (1.5 Gbps)
720p59.94
1080i50
1080i59.94
1080PsF23.98
1080PsF24
1080PsF25
1080p23.98ß
1080p24
1080p29.97
SMPTE ST 299-1 (limited to one pair, embedded on group 1, pair 1)
100 m (328 ft) (Belden 1694A)
< 0.2 UI p-p
BNC
3G-SDI Monitoring Outputs
Signal
Formats (Level A only)
Audio
Cable length
Return loss
Quantization
Jitter
Connectors
4:2:2 SMPTE ST 424:2006 (2.97 Gbps / 2.97/1.001 Gbps)
1080p50
1080p59.94
SMPTE ST 299-1 (limited to one pair, embedded on group 1, pair 1)
100 m (328 ft) (Belden 1694A)
> 15 dB up to 1.5 GHz
> 10 dB up to 2.97 GHz
8 bits
< 0.3 UI p-p
BNC
26
Kaleido-X16
Hardware Description & Installation Manual
Router Outputs
The Kaleido-X16 frame supports two 3G/HD/SD-SDI router outputs.
SD-SDI Router Outputs
Signal
Formats
Cable length
Return loss
Additive jitter
Connector type
4:2:2 SMPTE ST 259-C (270 Mbps), SMPTE ST 272:1994
525 and 625
225 m (738 ft) (Belden 1694A)
>15 dB up to 270 MHz
< 0.2 UI p-p (wideband)
BNC
HD-SDI Router Outputs
Signal
Formats
Cable length
Return loss
Additive jitter
Connector
4:2:2 SMPTE ST 292-C (1.5 Gbps)
720p59.94
1080i50
1080i59.94
1080PsF23.98
1080PsF24
1080PsF25
1080PsF29.97
1080p23.98
1080p24
1080p29.97
100 m (328 ft) (Belden 1694A)
>15 dB up to 1.5 GHz
< 0.2 UI p-p (wideband)
BNC
3G-SDI Router Outputs
Signal
Formats
Cable length
Return loss
Jitter
Connectors
4:2:2 SMPTE ST 424:2006 (2.97 Gbps / 2.97/1.001 Gbps)
1080p50
1080p59.94
100 m (328 ft) (Belden 1694A)
>15 dB up to 1.5 GHz + 10 dB up to 2.97 GHz
< 0.3 UI p-p (wideband)
BNC
27
Specifications
Audio I/O
Audio I/O
The Kaleido-X16 frame supports one SDTI audio input.
SDTI Audio Input
Signal
Cable length
Connector
SMPTE ST 305 (up to 128 channels/64 AES)
250 m (820 ft) (Belden 1694A)
BNC
The Kaleido-X16 supports audio monitoring through its HD-26 connector. The supported formats are the AES3 digital audio, and analog audio.
Analog Audio Output
Signal
Level
Quantization
Impedance
THD+N
SNR
Connector
Balanced analog audio
MAX + 24 dBu
20-24 bits
< 600 Ω
80 dB
92 dB
HD-26
AES Outputs
Signal
Format
Level
Impedance
Connector
Balanced digital audio
AES3
4 V p-p
110 Ω
HD-26
Control
The Kaleido-X16 frame supports two LTC unbalanced inputs for clock synchronization.
Time Code Inputs (LTC)
Signal
Electrical level
Impedance
Connector
SMPTE ST 309:1999, SMPTE ST 12:1995(EBU-3259-E)
0.3 to 5 V p-p
High Impedance (>10k Ω )
BNC
28
Kaleido-X16
Hardware Description & Installation Manual
Ethernet
Signal
Connector
RS-422
Signal
Connector
USB
Signal
Connector
The Kaleido-X16 supports 32 GPI inputs and 4 GPI outputs, on a DB-44 female connector.
GPI INPUT (up to 32)
Description
Pull-up voltage
Source current
Low-level activation
Over voltage
Connector
Contact closure to GND
3.3 Volts
30 μA when input shorted
0.8 Volts max
24 Volts max
DB-44
GPI OUTPUT (up to 4)
Description Contact closure to GND
Signal Open collector 5 to 12 VDC
Contact closure current 50 mA max
Reverse voltage
Reverse current
V out low
Connector
-15 Volts max
-50 mA max
0.6 Volts at 1.5mA
DB-44
10/100 BASE-T (IEEE 802.3)
RJ-45
RS-422 (SMPTE ST 207, EBU-3245)
RJ-45
USB Version 1.0
USB
Frame
Power supply
Input voltage
Frequency
Power
Hot-swappable redundant power supply
100-240 V
47.63 Hz
300 W @ 75% of PSU
29
Specifications
Frame
Max current
Max power
Dimensions
Full spec. temp. range
Storage humidity
Functional humidity
Weight (2 PSUs)
Weight (1 PSU)
4 A
300 W
H: 45 mm (1.75 in) (1 RU)
W: 451 mm (18 in) + mounting flange for standard 19-inch rack
D (with cover and connectors): 641 mm (25.25 in)
D (without cover and connectors): 591 mm (23.25 in)
0-40 °C (ambient)
90% RH non-condensing
65% RH non-condensing
10.5 kg (23 lbs)
9.5 kg (21 lbs)
30
Disposal and Recycling Information
Your Grass Valley equipment comes with at least one lithium button battery (Li-MnO
2
) located on the main printed circuit board. The batteries are used for backup and should not need to be replaced during the lifetime of the equipment.
Before disposing of your Grass Valley equipment, please remove the battery as follows:
1 Make sure the AC adapter is unplugged from the power outlet.
2 Remove the protective cover from your equipment.
3 Gently remove the battery from its casing using a blunt instrument for leverage such as a screwdriver if necessary.
4 Dispose of the battery and equipment according to your local environmental laws and guidelines.
WARNING
Be careful not to short-circuit the batteries by adhering to the appropriate safe handling practices. Do not dispose of batteries in a fire as they may explode. Batteries may explode if damaged or overheated. Do not dispose of batteries as household waste. Do not dismantle, open or shred batteries.
Keep batteries out of the reach of children.
The electrolyte of the batteries contains 1,2-dimethoxyethane (DME) (CAS
110-71-4, EINECS 203-794-9) above 0.1% by weight. DME is listed as a
Substance of Very High Concern (SVHC) by the regulation (EC) No 1907/2006 of the European Parliament and of the Council. It is classified as a reprotoxic of category 2 in the European Union. Accordingly, exposure to DME may impair fertility and may cause harm to the unborn child. DME is also classified as harmful by inhalation.
31
Disposal and Recycling Information
WARNING (continued)
Risk of exposure occurs only if the battery is mechanically or electrically abused. The most likely risk is acute exposure when a cell vents. In the event of a battery leak, do not allow battery liquid to come in contact with skin or eyes. Seek medical help immediately in case of ingestion, inhalation, skin or eye contact, or suspected exposure to the contents of an opened battery.
For more information about recycling, please contact Grass Valley.
32
Contact Us
Grass Valley Technical Support
For technical assistance, contact our international support center, at
1-800-547-8949 (US and Canada) or +1 514 333 1772.
To obtain a local phone number for the support center nearest you, please consult the
Product Support section of Grass Valley’s Web site, at http://www.grassvalley.com/ support/contact .
An online form for e-mail contact is also available from the Web site.
Corporate Head Office
Grass Valley
3499 Douglas-B.-Floreani
St-Laurent, Quebec H4S 2C6
Canada
Telephone: +1 514 333 1772
Fax: +1 514 333 9828 www.grassvalley.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 13 Kaleido-X16 Installation
- 13 Introduction
- 13 Features
- 14 Port Availability
- 14 Overview of the Kaleido-X16 System
- 15 Kaleido-X16-D
- 15 Kaleido-X16-S
- 16 Mechanical Installation
- 16 Unpacking
- 16 Mounting the Kaleido-X16 in a Rack
- 17 Frame and Electrical Installation
- 17 Frame
- 19 Monitoring the Temperature of the Kaleido-X16
- 19 Power Supplies
- 20 Removing a Power Supply
- 20 Installing a Power Supply
- 20 Powering up the Kaleido-X16
- 21 Ventilation
- 22 Frame Cooling Fans
- 22 Power Supply Cooling Fan
- 22 Air Filter
- 23 CompactFlash
- 23 Signalling
- 24 Inputs
- 24 Video Signals
- 24 Graphic Signals
- 25 Mosaic Outputs
- 25 HDMI Outputs
- 25 HD-SDI Monitoring Outputs
- 25 External Reference
- 26 Router Outputs
- 26 Audio I/O
- 26 Audio I/O TBA
- 27 Audio I/O TBA Pinout on the Kaleido-X16-D
- 27 Audio I/O TBA Pinout on the Kaleido-X16-S
- 28 Control
- 28 Linear Time Code (LTC)
- 28 GPI I/O
- 29 GPI Circuits
- 31 Ethernet
- 31 USB
- 32 RS-422
- 33 Maintenance
- 33 Cleaning the Air Filter
- 34 Replacing a Defective Power Supply
- 35 Specifications
- 35 Inputs
- 35 Video Signal Inputs
- 36 DVI Graphic Inputs
- 37 Outputs
- 37 Mosaic Outputs
- 39 Router Outputs
- 40 Audio I/O
- 40 Control
- 41 Frame
- 43 Disposal and Recycling Information
- 45 Contact Us