630140_1 XFIRE_1200_GB_Manual_R‐emotion
®
X-FIRE 1200
Designer Balanced Flue Fires
INSTALLATION & USERS INSTRUCTIONS
P
RODUCT
C
ODES
XT-TRA X-FIRE 1200 Travertine
LEAVE WITH THE USER
Acquisitions of London
24 Holmes Road
London NW5 3AB
England
Tel: 0044 (0)207 482 2949
Email: [email protected]
630140_1 XFIRE_1200_GB_Manual_R‐emotion
INTELLECTUAL PROPERTY
Acquisitions XFIRES is a Registered Trade Mark
Components of this product are protected under GB Patent no: GB2429186
Similar applications are pending in Europe, USA, Canada, China, Hong Kong,
Australia and New Zealand.
Important:
The appliance shall be installed in accordance with;
• This installation instruction booklet
• Local gas fitting regulations and The Rules in Force
• BS 5440-1
• BS 5871-1:2005 & BS 6891
• Any other relevant statutory regulations.
• Must be installed by a Registered Installer
• Converting this appliance for use with G31 Propane must be done by a Registered
Installer
•
•
This appliance is for use on Natural Gas (G20) at a supply pressure of 20mbar or
Propane(G31) at a supply pressure of 37mbar.
In IE, consult document I.S. 813:1996 Domestic Gas Installation.
DISTRIBUTED BY
Acquisitions of London
24-26 Holmes Road
London NW5 3AB
Tel: 24 hours 0044 (0)207 482 2949
Email: [email protected]
630140_1 XFIRE_1200_GB_Manual_R‐emotion
Note:
THERE ARE A FEW THINGS TO CONSIDER BEFORE INSTALLATION
• Cavity Dimensions and Clearances
• MUST be installed 100mm minimum off the floor or nearest horizontal surface.
• Coupling of flue to fire
• Coupling of gas lines to fire
• Fixing the fire to cavity
• Gas pipe placement to the front left of the cavity.
• Before installation, ensure that the local distribution conditions (identification of the type
of gas and pressure) and the adjustment of the appliance are compatible.
The sequence in which it is desired to undertake these tasks may vary upon the individual installation that is required. Please read these instructions fully before proceeding with the installation. Leave unpacking and installation of the stone frame (facia) until the fireplace has been commissioned, to avoid damage to the facia panels.
Recommended Installation Process:
The following diagram illustrates the steps required to install your gas fire, and the trades required at each stage.
Builder
1. Construct Frame (Section 1.0 to 6.0)
Gasfitter
2. Install Gas Pipe (Section 7.0 to 8.0)
3. Install Fire (Section 9.0 to 11.0)
Ensure that you leave a gap between the studwork and the fire chassis to accept the wall lining if applicable.
Gasfitter
4. Install Flue + Flue Restrictor if required (Section 12.0 to 13.0)
5. Test fire and verify flame pattern is acceptable
6. Cover‐up fire using packaging (Section 17.0)
Builder
7. Clad / line chimney breast
Gasfitter
8. Commission the Gas Fire (Section 18.0)
630140_1 XFIRE_1200_GB_Manual_R‐emotion
Contents:
1.0
Description
2.0
3.0
Creating
Hearth
4.0
Linings
5.0
Clearances
6.0
Installations
7.0
Laying
8.0
Connecting
9.0
Supply
10.0 Fixing
11.0 Removing the Firebox Glass
12.0
Installing system
13.0 Fitting
14.0 Converting
15.0
Placing Bed
16.0 Checking Pressure
17.0 Covering
18.0 Commissioning the Fire (Including fitting the facia)
19.0 Operating
20.0 Sounds Smells
21.0
Annual
22.0
Installation
Terms Conditions
WARNING:
Failure to follow these instructions could cause a malfunction of the fire, which, could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void insurance cover and/or product warranty.
Installation:
Installation must be carried out by a registered installer who, on completion of the installation, must issue a certificate of compliance, in accordance with national and/or local codes. To find a registered installer in the UK go to the Gas Safe website – www.gassaferegister.co.uk In the rebulic of Ireland go to www.rgii.ie
Warranty Repair and Annual Servicing:
Warranty repair work must be carried out by a registered gas installer. It is recommended that registered gas installers are also used to carry out annual servicing requirements
(particularly during the warranty period). For contact details of UK registered gas installers in your area, go to the Gas Safe website at www.gassaferegister.co.uk
and in the Republic of Ireland go to www.rgii.ie
This product must be installed according to these instructions and in compliance with all relevant building, gas fitting and other statutory regulations (eg. BS 5871-1:2005,
BS5440-1 and BS 6891 ). Any shortcomings in the appliance and flue installation will be the responsibility of the installer, and Escea will not be accountable for any such failings or their consequences.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
1.0
Product Description:
The XFIRE 1200 decorative gas fire is designed to be built into a cavity. The appliance is flued via Simpson Duravent Direct Vent Pro 5” x 8” Flue, available only from SpecFlue.
Users may control their fire with the Radio Frequency (RF) remote. The glass on the front of the appliance is considered a working surface, and as such, care should be taken not to touch this while the appliance is running as it will get hot.
1.1 Energy Input Ratings:
The following table states the energy input rates for the ST900 Gas Fireplace on all settings for both possible gas types (XFIRE 1200 is set for G20 Natural Gas upon manufacture).
Gas
Minimum (kW)
Intermediate (kW)
Maximum (kW)
G20 Natural Gas
3.9 kW
4.6 kW
4.8 KW
G31 Propane
5.2 kW
5.4 kW
5.5 kW
630140_1 XFIRE_1200_GB_Manual_R‐emotion
2.0
Creating the Cavity:
The dimensioned drawing below shows the size of opening that must be created to fit the
XFIRE 1200. The wall directly above the fire should be finished / clad / lined after the fire has been installed, unless there is an access hatch or the chase is open to the ceiling cavity, which allows the flue to be installed after the wall has been lined.
The wall and framework in front of the flue must not exceed 100mm in thickness, this includes plaster board or any wall linings. This is to ensure there is at least 25mm gap between all fluing components and any combustible material.
100mm MAX
Flue Diam.
203mm
3.0
Hearth and Floor Clearances:
There should be at least 100mm between the bottom of the XFIRE 1200 and any horizontal surface below, for example hearths and floors.
3.1
Wall and Cabinet Clearances:
There must be a minimum of 100mm from the sides of the facia to any protruding side walls or cabinetry.
4.0
Wall Linings:
The wall board that lines the outside of this opening can be normal dry wall
(Plaster Board) and does not need to be non-combustible providing that it does not come any closer to the fire than the dimensions shown in section 2.0. Note: The temperature of the wall lining directly above the heater does get warm and hence may discolour paint finishes that are susceptible to temperature damage or distort vinyl wall coverings.
5.0
Television Positioning Considerations:
It is becoming common practice for consumers to mount flat screen TV’s above their gas
fireplace.
Most TV manufacturers have specified in their instructions that the TV should not be installed on, near or above a heat source. For this reason TV location decisions rest solely with the householder and Escea will not be held liable for any adverse affects on a TV located near to an Escea fireplace that may be caused by heat.
The drawings overleaf are suggestions that may be used as a GUIDE for those consumers who do decide to locate their TV above an XFIRE 1200 gas fire. These drawings show ways to reduce the amount of warm air rising off the fireplace and onto the TV
630140_1 XFIRE_1200_GB_Manual_R‐emotion
Recessed TV
50 min
50 min
50 min
Flush TV with small mantle
50 min
50 min
Mantle
Mantle above fire
100 min
100 min
Mantle
Protruding fire
50 min
50 min
500 min
500 min
500 min 500 min
The material that the wall and mantle are made from will also affect the operating temperature of the TV so it is the customers responsibility to satisfy themselves that their
TV mounting and mantle design will not exceed the listed maximum operating temperature of their electronic goods.
5.1 Combustible Mantle Clearances:
The diagram to the right shows the minimum and maximum allowable size for mantles or protruding surfaces mounted above the XFIRE 1200.
Note: Acquisitions does not recommend placement of items on the mantles shown in the diagram to the right. This is because of the potential for items placed on or above the mantle to be affected by the heat rising from the appliance.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
5.2 Non-Combustible Mantle Clearances:
If the entire installation (mantle, wall and cavity) is constructed from non-combustible materials, the clearances to mantles may be as shown in the shaded area.
6.0
Corner Installations:
If a cavity is to be created in a corner, the following drawing gives the minimum
sizes.
7.0
Laying Gas Pipe:
Gas pipe should be sized as per the requirements of BS 6896. The pipe sizing must be sufficient to deliver the following volume of gas to the heater with all other gas appliances in the home running at the same time on Natural Gas (G20).
XFIRE 1200 = 4.8kW
XFIRE 1200 = 0.45 m
3
/h
630140_1 XFIRE_1200_GB_Manual_R‐emotion
8.0
Connecting the Gas Pipe to the Fireplace:
Before the gas pipe can be connected to the fireplace, the Inlet Connection fitting and the
Inlet Test Point fitting must first be fitted to the appliance pressure regulator.
8.1 The fittings supplied with the fire need to be fitted to the pressure governor. A suitable joint sealant and/or thread tape needs to be used on these unions.
The diagram below shows how to correctly assemble these two fittings to the pressure regulator inlet side connection.
8.2 Soft copper should be run directly to fire and connected onto the regulator by means of an
8mm diameter compression fitting. An accessible inline isolation or service valve should also be fitted. The regulator that is supplied with the fire MUST NOT BE REMOVED.
Removal of the regulator, or replacing it with one not intended for use with an XFIRE 1200, will void the limited appliance warranty and could result in an unsafe installation.
9.0
Battery-Pack Power Supply:
The XFIRE 1200 runs on a battery pack. This battery pack uses 3x D cell batteries. To ensure that only fresh batteries are used, batteries are not supplied with the fireplace.
These will be supplied by the installer.
To access the battery pack, remove the facia (described in section 17.0) and the battery pack will be on the lower right hand side.
The Battery Pack is secured in place with Velcro pads and may be removed by firmly
630140_1 XFIRE_1200_GB_Manual_R‐emotion
10.0
Fixing the Fire to the base and wall:
It is a requirement that this fire be securely fastened to the wall and base. Once the fire has been pushed back into the correct position, use wood screws (or other suitable fasteners) to fix the fire to the cavity through each of the four holes in the corners, as shown in the diagram to the right. Note: It may be necessary to use washers on the fasteners to securely fasten the fire to the wall.
When fixing the fireplace in position ensure that you leave a gap between the fireplace flange and the framing timber for the wall lining, which will be added at a later stage.
11.0
Removing the Firebox Glass:
Pull the four hooks shown below towards you and then away from the glass to release the glass frame underneath the hook.
Do not operate the appliance if the glass has been broken, damaged, or the glass is not properly positioned/hooked onto the appliance.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
12.0
Installing the Flue System:
Ensure all flue components are Simpson Duravent Direct Vent Pro 5” x 8,” no other flue types may be used. This flue is available on 24 hour delivery only from SpecFlue UK
FreeFone 0800 9020220 International +44 1787 880333
Note: Consult section 12.13 of this installation manual to ensure correct length of flue is calculated.
There are two basic types of Balanced Flue System installations:
• Horizontal Termination
Use the diagrams in sections 12.5, 12.6 & 12.7 to check if your proposed flue system is acceptable. Section 12.9 will also need to be used to determine whether the flue terminal location meets the requirements of BS 5440-1. Then use Appendix A to work out the quantities of the flue components that are required.
12.1
Any offsets in your flue configuration should be 45 ° where possible .
12.2
If your flue configuration has a horizontal run, there must be a minimum 1 ° inclination
(20mm vertical rise per 1m horizontal run) leading upwards towards the termination.
Do not install the flue with horizontal sections sloping down towards the termination.
This could cause the fire to operate incorrectly and possibly create an unsafe condition.
12.3
The flue must maintain the following clearances to combustible materials;
25mm from all sides and bottom of the flue, and 50mm from the top of flue.
115 mm (REF)
25 mm
25 mm
50 mm
25 mm
25 mm
50 mm
Flue
25 mm
25 mm
30 Elbow
12.4 If your flue configuration falls on or near a restriction zone boundary line in diagrams 12.5,
12.6 & 12.7, it may require the restriction value from either side of the boundary line to achieve the correct flame aesthetic, this may vary from installation to installation.
12.5 Vertical Only Flue Diagram:
630140_1 XFIRE_1200_GB_Manual_R‐emotion
Use this diagram to determine what percentage of flue restriction is required to ensure safe and correct operation of the
XFIRE1200 balanced flue decorative gas fireplace.
12.6 Horizontally
Use this diagram to determine what percentage of flue restriction is required to ensure safe and correct operation of the
XFIRE1200 balanced flue decorative gas fireplace.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
12.7 Vertically
630140_1 XFIRE_1200_GB_Manual_R‐emotion
Use this diagram to determine what percentage of flue restriction is required to ensure safe and correct operation of the
XFIRE1200 balanced flue decorative gas fireplace.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
12.8
Standard Flueing Configurations:
The following flue components are available from your SpecFlue, UK FreeFone 0800
9020220, International +44 1787 880333 in kitset form.
DVF‐H
DVF‐V
630140_1 XFIRE_1200_GB_Manual_R‐emotion
12.9 Locating the Flue Terminal:
The flue terminal must be located using the information given in the following excerpts from
BS 5440-1.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
630140_1 XFIRE_1200_GB_Manual_R‐emotion
630140_1 XFIRE_1200_GB_Manual_R‐emotion
Figure C.2 Minimum dimensions of room-sealed chimney outlet positions
(refer to Figure C.8)
Symbol Location
(kW input expressed in net)
A
B
C
D
A)
A)
A)
I
J
K
L
M
N
O
P
Q
E
F
G
H C)
Directly below an opening, air brick, opening windows, (0-7 kW) etc (>7-14 kW)
(>14-32 kW)
(>32-70 kW)
Above an opening, air brick, opening window, etc (0-7 kW)
(>7-14 kW)
(>14-32 kW)
(>32-70 kW)
Horizontally to an opening, air brick, opening windows, (0-7 kW) etc (>7-14 kW)
(>14-32 kW)
(>32-70 kW)
Below temperature-sensitive building components, e.g. plastic gutters,
Soil pipes or drain pipes
Below eaves
Below balconies or car port roof
From vertical drain pipe or soil pipe
From an internal or external corner
Above ground, roof or balcony level
From a surface facing the terminal
From a terminal facing the terminal
From an opening in the car port (e.g. door, window) into the dwelling
Vertically from a terminal on the same wall
Horizontally from a terminal on the same wall
From the wall on which the terminal is mounted
From a vertical structure on the roof
Above intersection with roof
Minimum dimensions
Natural
Draught
300 mm
600 mm
1 500 mm
2 000 mm
300 mm
300 mm
300 mm
600 mm
300 mm
400 mm
600 mm
600 mm
300 mm
300 mm
600 mm
300 mm
600 mm
300 mm
600 mm
600 mm
1 200 mm
1 500 mm
300 mm
0
N/A
N/A
Fanned
Draught
300 mm
300 mm
300 mm
75 mm
200 mm
200 mm
150 mm
300 mm
B)
300 mm
600 mm
1 200 mm
1 200 mm
1 500 mm
300 mm
0
N/A
300 mm
NOTE N/A = Not applicable.
A)
In addition, for temperature and structural reasons, the terminal should not be nearer than 150mm (fanned draught) or 300mm (natural draught) to an opening in the building fabric formed for the purpose of accommodating a built-in element such as a window frame (see Figure C.9). Separation distances are linked to the rated heat inputs as shown.
B) This dimension may be reduced to 75mm for appliances of up to 5 kW heat input.
C) The reference to external corners does not apply to building protrusions not exceeding 450mm, such as disused chimneys on external walls for; fanned draught appliances; natural draught appliances not exceeding a net input of 7 kW; any other appliances if detailed in the appliance manufacturer’s instructions.
If using a horizontal flue terminal, a guard must be fitted to the terminal where it is located less than 2m above the ground, above a balcony or flat roof to which people have access.
This guard is available from SpecFlue, UK FreeFone 0800 9020220,
International +44 1787 880333
12.10 Supporting the flue system:
Wall straps are required to fix the flue system in place for each installation. This will ensure that no undue strain is placed on flue components once installed.
For a flue offset or horizontal run, it is recommended that wall straps be used to the flue system with a spacing of 900mm between straps. Plumbers strapping / tape can be used to connect the wall straps to the building structure where there are large distances between the support point and the anchor point.
For vertical flue runs it is recommended that wall straps be used to anchor the flue system with a spacing of 1200mm between straps.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
12.11 Sealing ‘through roof’ and ‘through wall’ penetrations:
For ‘through roof’ penetrations, use a Master Flash flashing or equivalent to create a weather-tight seal between the flue and the roof cladding.
For ‘through wall’ penetrations, this will require the use of a Wall Thimble. The Wall Thimble will ensure you have suitable clearance from combustibles as well as sealing the penetration. The section of the wall thimble installed on the external surface of the wall should be sealed to the wall using a high temperature sealant such as Envirograf Product
62, Sealocrete Heat Resistant Silicone or equivalent. Additional sealant is required to seal the Terminal Cap to the external wall. A bead should be run along the edge of the Terminal that will be in contact with the wall once installed.
12.12
Twist locking procedure:
Before connecting flue components, to ensure an airtight seal run a single 7-8mm bead of
Sealocrete Heat Resistant Silicone, or equivalent, on the ‘male’ end of the flue as shown in the diagram below.
The four indentations located on the female end of the flue are designed to slide straight onto the male ends of the adjacent flue length, by orienting the four flue indentations so they match and slide into the four entry slots on the male ends.
Push the pipe sections completely together, then twist-lock one section clockwise
Wipe off any excess sealant from the exterior of the flue joint.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
12.13
Points to note when planning the Installation of the Escea DV flue:
- This flue system cannot be cut to length. Correct lengths must be selected for each installation. For a full list of available flue lengths, contact your Escea retailer.
- The listed length of the flue pipe is not the installed length. 1 ½” (38mm) needs to be subtracted for each join to determine the installed length of each piece of flue pipe.
E.g. 48” length has installed length of 45”.
- All vertical measurements should be measured from the top surface of the fireplace casing itself (not the facia).
- When using horizontal flue runs, vertical measurements should be measured to the centre line of the horizontal flue pipes.
- When using 90° elbows in the installation, use the diagram below to help calculate installations horizontal and vertical distances. 1½” (38mm) will still need to be subtracted from each join.
- If using a 45° offset in your installation, consult the chart below to select the required flue length to give the desired offset. 1½” (38mm) will still need to be subtracted from each of the 45° bends to allow for the joins.
Straight Offset: Rise:
Flue Length:
0”
6”
9”
12”
24”
36”
48”
5 5
7 /
/
8
7
8
” 15 3 /
8
”
8
10
” 18
/
8
” 20 5
/
/
8
”
13” 22
21 3 /
8
”
29 7
38 1 /
4
”
31 1
/
8
” 39
47
5 /
7
/
/
/
8
”
8
8
8
”
”
”
- Adjustable lengths are available depending on stock levels. Contact Spec-Flue for more information.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
13.0
Fitting the Flue Restrictor:
If your flueing configuration requires that you fit a flue restrictor
(see graphs in section 12.5, 12.6 & 12.7 of this manual to find out if your configuration requires a flue restrictor
), follow the instructions below.
First, prepare the Flue Restrictor by removing and discarding the inner rings to achieve either 60%, 70% or 80% restriction as required and hand bending the five tabs 90°
Remove the firebox glass (if fitted), and using a Phillips /
Pozi Drive screwdriver remove the two screws located inside the firebox as shown.
Once the two screws are removed the baffle will be free to slide down and out as pictured. Ensure the firebox paint is not scratched and that the baffle is not damaged
Fit the flue restrictor by pushing it up into the flue with the tabs facing downwards as shown. Push it up into the flue until the tabs no longer protrude into the firebox and it is securely placed. If the restrictor is loose or will not stay in position manipulate the five tabs to suit.
Once the restrictor is in place, replace the baffle taking care not to damage or scrape the paint, and replace the two screws.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
14.0 Converting to G31 Propane Gas:
Where a conversion to propane gas is needed, the following steps should be followed
14.1
First you need to remove the burner by removing the screw holding it in place on the left hand side of the firebox (Fig. 1).
Then remove the 1.9mm burner jet (Fig. 2) and replace it with the 1.3mm jet supplied in the kit.
Now remove the gas pipe fitting under the pilot (Fig. 3) and remove the No.48 pilot Jet
(Fig. 4) and replace it with the No.46 pilot jet supplied in the kit.
Replace pilot line.
Adjust the Primary Aeration Collar on the burner to the Propane position as shown in the diagram below, then place the burner into position and screw it in place.
The gas regulator needs to be converted from the Natural Gas setting to the Propane setting.
The regulator is located on the left hand side of the control tray, at the base of the fire. To change the regulator between Natural Gas and Propane, unscrew the top cap off the regulator and pull the plunger from it. Re-insert the plunger on the opposite side (as shown in the diagram to the right) and screw the assembly back in the stack
Finally, put the sticker supplied in the conversion kit in onto the dataplate of the ST900 in the position shown.
The sticker must be signed and dated by the installer who has converted the fire.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
630140_1 XFIRE_1200_GB_Manual_R‐emotion
15.0
Placing the Fuel Bed Media:
Your XFIRE 1200 Gas fire will be supplied with a Fuel Bed kit. Follow the instructions below for the Fuel Bed kit that applies to you.
First scatter one layer of the supplied white stones evenly across the base of the firebox, ensuring there are no stones or driftwood pieces inside the pilot flame surround guard.
Arrange the supplied driftwood pieces exactly as shown in the diagram and photo below.
Underneath each piece of driftwood is a written number which will help in correctly positioning it within the firebox.
Ensure no coals, driftwood, or other material are inside the pilot flame surround guard, and the pilot flame is clearly visible. If any loose material is inside this guard it may interfere with the pilot and ignition system.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
16.0
Checking Operating Pressure:
WARNING: The regulator that is supplied with the fire MUST NOT BE REMOVED.
Removal of the regulator, or replacing it with one not intended for use with an Escea fire, will void the limited appliance warranty.
Check the operating pressure at the regulator located at the front LH corner of the appliance. This is best done before the facia panels have been fitted to avoid facia damage. Pressure test points are available for both inlet and operating test pressure (as below).
1) Remove inlet pressure test point screw and attach manometer tube.
2) Run the fire on full and measure inlet pressure with all the other gas appliances running. If pressure does not fall within the pressure tolerances listed on the table below then the installation pipe size or upstream regulator settings are incorrect.
If the correct supply pressure cannot be obtained, then the fire gas supply must be disconnected until the fault is corrected.
3) Remove the manometer and replace inlet test point screw.
4) Remove the operating pressure test point screw. Connect manometer tube and measure pressure with fire running on full and with all the other gas appliances
running.
5) Replace operating pressure test point screw and leak test inlet and operating pressure test points and inlet gas connection unions.
A = Inlet gas connection
C = Gas Conversion Cap
D = Operating Pressure test point
XFIRE 1200 Technical Data
Inlet Pressure
Operating Pressure
Injector size
Propane (G31)
37 mbar
23 mbar
1.3mm
Gas Type
Natural (G20)
20 mbar
+
/
‐
1.5 mbar
10 mbar
1.9mm
630140_1 XFIRE_1200_GB_Manual_R‐emotion
17.0
Covering up the fire:
Before the wall surrounding the ST900 is lined, the fire must be covered up and sealed to prevent plaster board and plaster dust from getting into the fire. It is recommended that the packaging supplied with the fire is used to achieve this.
18.0
Commissioning the Fire:
After the cladding and finishing processes are completed, the gasfitter must return to the site to run the fire for a minimum of 20 minutes and finally assemble and fit the facia.
18.2
Fitting the stone frame:
Take care when handling the facia and get help if necessary. The Facia Brackets have been fastened to the facia in flat-pack form to help protect the facia during transport.
Remove the 8 screws shown below holding the brackets in place.
To assemble the two brackets removed in the previous step, use the 8x screws removed to re-fasten the brackets to the facia as shown below. Position the brackets with the flange facing outwards, and the hooks facing the bottom of the facia [Identify the bottom of the facia by the large cut-out shown below].
630140_1 XFIRE_1200_GB_Manual_R‐emotion
The stone frame uses these four hooks for attaching to the fire. Do this by lining up the
facia hooks with the receptacles on the sides of the fire. Lift the facia so that the hooks are above the receptacles, and let it drop down into position until it is secure and free from
Care should be taken when handling the facia.
To remove the frame, lift it upwards briefly, and then pull towards you. Ensure the facia is allowed to cool before attempting to remove it.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
18.3 Cleaning:
Before carrying out any of the following operations, ensure the the appliance is OFF and
completely
Glass Panel: Remove as described in section 11. This can be cleaned inside and out with proprietary window-glass cleaner, or proprietary ceramic hob cleaner if badly stained.
Test on a small area first. Do not allow the glass to become badly stained as this will be difficult to remove.
Limestone Surfaces: Remember that limestone is porous and therefore susceptible to marking in use. The limestone frame may be cleaned with a small amount of warm soapy water. Any stubborn stains may be removed with a diluted liquid domestic bleach and water solution. Superficial scratches or stubborn surface stains can be smoothed out using a fine grade wet & dry sandpaper. Joints may be grouted using a matching tile grout. The limestone frame may be sealed with an appropriate stone sealer (consult the retailer). This will give some protection against staining such as red wine, tea or coffee, but may darken the stone slightly.
Travertine Surfaces: Remember that stone is porous and therefore susceptible to marking in use. This frame may be cleaned with a small amount of warm soapy water. Any stubborn stains may be removed with a diluted liquid domestic bleach and water solution.
The frame may be sealed with an appropriate stone sealer (consult the reailer). This will give some protection against staining such as red wine, tea or coffee, but may darken the slightly.
Granite Surfaces: In everyday use, a soft lint-free duster should be used to keep the granite clean and free of dust. Other marks, such as finger-prints may be removed form the granite frame by using a proprietary window glass cleaner, or NET-TEX Hard Surface
Cleaner.
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. NEVER OPERATE THE UNIT
WITH THE GLASS REMOVED.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
19.0
Operating Instructions:
The XFIRE 1200 remote control allows you to turn ON and OFF the fire, control the flame height in the Manual mode, or control the room temperature in the Thermostat mode. The remote has a maximum range of approximately 10 meters, and because the remote works by radio frequency, it does not need to be aimed at the XFIRE 1200 for it to operate. The remote control runs off 3x AAA batteries which are supplied in the same packaging as the remote.
The remote control is supplied with a wall-mount cradle; the installer should mount this at a location determined by the customer.
19.3
Switching on the XFIRE 1200:
Note:
If this is the first time running the XFIRE 1200 the air will need to be purged from the gas lines. To do this, follow the instructions below to switch the fire on and then switch it off. Repeat this up to 10 times until the pilot flame successfully sparks and ignites.
When first powered the remote starts at the OFF screen (it is possible that the remote is locked in the OFF screen: to unlock it just press the button below Unlock, and then OK).
Switching on: Once the remote is unlocked, press On (left button) and OK (middle button).
A beep from the control unit will be heard, and the ignition process starts (the pilot will start sparking and gas will start flowing to the pilot, which should then be lit within a few seconds). Note that while in operation the RF signal strength indicator disappears.
Wait until the current flame status displays pilot.
If the pilot flame fails to ignite, you must turn OFF the fire from the remote and start the process of turning it ON again.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
19.4
Switching off the XFIRE 1200:
To turn off the fire, push the OFF button, to shut down the gas flow to the fire and switch it off. The OFF display will now appear in the display.
19.5
Setting the control mode for the fireplace:
There are three different modes for controlling the appliance:
> Manual
> Automatic
> Program
Automatic mode allows you to set a temperature, while in manual mode the flame level may be set to HIGH, MEDIUM, LOW & PILOT. Program mode offers automatic temperature control for specific times of the day.
In the initial screen when the remote is turned on, three options are available: AUTO,
MANUAL and MENU.
Auto and Manual are two of the three different modes for controlling the appliance with the remote.
> Manual mode:
If Manual is pressed, Pilot appears as the selected setting. In the bottom row, ↓ and ↑ appear, indicating that the flame level can by changed by just pressing the left or middle button. There are four possible flame positions:
Pilot flame, Low flame, Medium flame and High flame.
Pressing Back (right button), returns to the initial screen.
Note that a Safety temperature can be previously set in the configuration menu. This specifies the maximum the maximum permitted room temperature. This temperature can never be set higher than 40ºC (104 ºF).
> Automatic mode:
If Auto is pressed in the initial screen, 25ºC (77 º F) appears as the desired temperature in the selected setting. In the bottom row, ↓ and ↑appear, indicating that we can change the desired temperature value by just pressing the left or middle button. In auto mode the appliance heats until this temperature is reached. Limits are 0-37ºC (32-99ºF).
Pressing Back (right button), returns to the initial screen.
The Auto mode feature is optional and can be enabled or disabled in the configuration menu (see specific chapter).
In this mode the main burner can be switched on and off.
e:
By defa de is not e nabled. To rogram mo configurati ion
FF button f for 40 seco gramming”
). and mode, every day progra m, so it is possible h erent progr am for eac he daily mode, ever ry day has its own
In this mode the menu: (Men
Daily, and the others esday, Thu rsday, Frid screen of:
Program) gramming
Daily prog ram:
A: Selecte ng “Daily”).
. The
B:
Day sc hedule gra ays the tempe rature sett ton). whole day on). g ng essing → ( (left button e desired t
) and then emperatur press re,
[Small bar] No te rs):
Off
-
Nigh e will heat ture. until this te ot mode).
re is reache ht and set p -
[Large bar] The c e will heat until this te re is reache menu →
Comfo rt and set mfort temp erature pre ture. the
Finally , to launch in the mai n menu, se
Type (Dai ily or week activated, above temperatu w which of t the or Comfor rt. The pilot lit in or rder for the to remain r running.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
19.5
Changing the display from Celsius to Fahrenheit:
Go into Menu → Adjust menu → Unit. Press middle button and then left button for changing units.
19.6
To Lock / Unlock the remote control buttons:
Go into Menu → Lock. Press middle button and then left button for locking the remote.
To unlock press left button and then middle button.
19.7
Replacing batteries:
When batteries are replaced in either the Battery box (inside the fireplace) or in the handset, then the unit will require 1 minute afterwards to regain connection.
19.8
Operation from the Touch Pad:
The touch pad is intended to be used for service/diagnostic purposes and to operate the fire in the event that the remote handset becomes lost or inoperative.
If you remove the fascia you will find an electronic touch pad in the lower centre of the fire.
The touch pad features the basic operations of the fire: On, off, and manual adjustment of the flame height.
To turn on the XFIRE 1200, push the ON/OFF button on the touch pad. The system will emit a beep and begin the ignition process, which can take about 20 seconds. Once the start up process is complete, the pilot flame is lit. The XFIRE 1200 is now in the ‘Manual’ mode and ready to be used.
While the pilot is lit, press the ‘Flame Up’ or ‘Flame Down’ button to alter the flame height.
The LED will flash once and the unit will beep to confirm the flame height has been adjusted. The XFIRE 1200 has 4 flame positions: Pilot only, Low, Medium, and High flame height.
If the ‘Flame Up’ button is pressed while the unit is in the ‘high’ flame position, nothing will happen. Similarly, if ‘Flame Down’ is pressed while the unit is in the ‘pilot’ flame position, nothing will happen.
To shut down the gas flow to the XFIRE 1200, press the On/Off button and the LED will begin to blink and the unit will emit a beep.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
19.9
Pairing the Remote to the Control Unit:
Install batteries to the battery pack and after a while the valve motor will start moving (if not wait one minute from the time of installing batteries). Once the valve has finished moving, press the OFF button on the remote control for 40 seconds. During this time the screen may go blank, this is normal. After 40 seconds, the configuration menu appears:
All the operation must be done on channel A (go to the last option in the setup menu by pressing ↓ and select channel A).
After that, go to pairing option again and press the select button (middle button) and when off is highlighted, press the change button (left button) off becomes on.
Once the pairing is on, there are 20 seconds to push
(press and release) the button S1 (yellow) in the control unit.
Once this operation is done, you hear a beep in the control unit and on the remote control will appear:
The indication on the pairing menu option will now become off and the pairing is over. To return to the home screen press the back button until you get to main screen.
PS: If the pairing has been attempted previously and has not been achieved, do the following:
- Prepare the command by pressing the key OFF for 40 seconds.
- Set the channel on channel A.
- Select On in the pairing setting.
- Remove the batteries from the control unit (wait 10 seconds) and put the batteries back.
- Once the valve has finished moving, repeatedly push (press and release) the S1 button
(yellow button on the control unit), until you hear the beep that confirms that learning has taken place.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
19.10
Initial configuration:
To enter the configuration menu, press the OFF button on the remote control for 40 seconds.
During this time the screen may go blank, this is normal. After 40 seconds, the configuration menu appears.
It is possible to configure the appliance with the following options:
• Thermostat: This option enables or disables the auto thermostat mode. To enable it, select
Yes. To disable it select No.
• Gap Temp: This option refers to the tolerance between the desired temperature and the current one. If the difference is greater than this gab temperature setting, the flame level increases.
For example: the desired temperature is set at 20°C and the current temperature is 18°
• If the Gap Temp is 0•5°C: Flame level will go to maximum level because the difference is 2°C.
• If the Gap Temp is 1°C: Flame level will go to medium level as difference of 2°C is two times the gap setting. (The flame level increases two levels: Pilot → Low →
Medium.)
• If the Gap Temp is 2°C: Flame level will go to minimum level as the difference of 2°C is equal to the gap setting. (The flame level increases one level: Pilot → Low.)
• Programming: this option enables or disables the program mode. To enable it, select Yes.
To disable it, select No.
• Fan System: This option enables or disables the fan system. To enable it, select Yes. To disable it, select No.
• Soft start: this option causes the thermostat mode to work incrementally. When the change of flame level required by the thermostat involves more than one level, this option makes the change step by step, with a delay of 10 seconds between each change of flame level.
To enable this option, select Yes. To disable it, select No.
• Ember bed: this option enables or disables the ember bed output. To enable it, select Yes.
To disable it, select No.
• Sounder: This option enables or disables the sounder option. To enable it, select Yes. To disable it, select No.
• Safety temp: This temperature is the maximum permitted room temperature. If the remote detects that the temperature is higher than the Safety temp, the appliance is switched off.
This temperature can never be set higher than 40°C (104°F). The possible range of values is 25-40°C (77-104°F).
• Channel: There are three different channels available: A, B and C. A change of channel should be done if communication is no good, and only after pairing has been done. Never try to do channel change and a pairing at the same time. To change the channel just press
Select
, choose one of the channels and then reset the control unit by disconnection the power supply for a short period. Afterwards the connection between the remote and the control unit will be re-established. This process can take 10 seconds.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
20.0
Sounds and Smells:
Note: Each time the fire is lit from cold, the glass may mist with condensation. This is normal and the condensation will disappear within a few minutes once the glass heats up.
20.1
Sounds:
It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various types of materials used within your appliance.
Listed below are some examples. These are all normal operating sounds and should not be considered as defects in your appliance.
Gas Control Valve:
As the gas control valves turn ON and OFF, a dull clicking sound may be audible, this is normal operation of a valve. When the fire is switched off after being run for a while, there may be popping and fluttering noises as the residual gas in the burner burns away. These are normal and should be no cause for concern.
Unit
Different types and thicknesses of steel will expand and contract at different rates resulting in some “dull drumming” and “ticking” sounds being heard throughout the cycling process.
20.2
Smells:
The first few times the unit is operated, the unit may release an odour and the flames may appear orange caused by the curing of the paint, the burning off of the starch in the gas coals and the oils in the metal and finishes. This is a temporary curing process which will disappear with use.
A deposit on the inside of the glass, caused by the starch in the coals may appear as a build up after several uses. If this film is not removed, it may bake on and may become difficult to remove. When the glass is cold, remove it (see section 11.0) and clean the inside with a non-abrasive cleaner.
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. NEVER OPERATE THE UNIT
WITH THE GLASS REMOVED
630140_1 XFIRE_1200_GB_Manual_R‐emotion
21.0 Annual Service Check:
The Fireplace should be serviced annually to ensure it continues to operate in a safe manner. This annual service check should involve the following
• Replace
• Check glass assembly gasket
• Clean pilot and main burner jets
• Paint firebox [if required]
• Inspect flue system [if possible]
• General clean and inspection
22.0
Installation Check List:
1
Fuel bed correctly installed as per manual
2 and all other gas appliances in the house switched on.
Flue restrictor fitted if required, flame picture verified 15 minutes start-up.
4 Ensure the pilot frame is clearly visible and free from loose material (coals or gravel). doors and windows open to clear smell of paint and oils during initial burn.
7 done on pipe work.
10
11 filled in their own details and fire serial number into warranty card.
installation
630140_1 XFIRE_1200_GB_Manual_R‐emotion
24.0
WARRANTY TERMS & CONDITIONS:
This warranty does not affect your statutory rights.
Provided that the Product is installed as stated in the Installation Manual and the step by step warranty procedure has been followed in accordance with Acquisitions written procedures, and the product has been operated and maintained in accordance with these operating and maintenance instructions, then for the first period of twelve (12) months from the date of purchase the cost of repairing or replacing any part of the Product that is deemed at fault will be the responsibility of the retailer or
Acquisitions Fireplaces Limited.
For the second period of twelve (12) months from the date of purchase replacement parts will be supplied free of charge except for the cost of carriage.
Parts and Labour for the first twelve (12) months: a) Acquisitions, at its sole discretion, may modify, adjust, repair, or replace the faulty products. The warranty period on parts and labour shall be for twelve (12) months from the date of purchase. b) Stone facias are made from natural materials which will include natural features such as vents, pinholes, minor fissures and fossils or other markings. These are not regarded as faults and may not be claimed as such under warranty.
Parts Only for the second twelve (12) months: a) Acquisitions, at its sole discretion, will provide replacement parts to the Distributor, retailer or repair service. Faulty parts MUST be returned. The parts only warranty period shall be for twelve (12) months and will commence twelve (12) months after the acceptance date of the Products by the retailer.
General Terms and Exclusions:
1. All repairs made within the Limited Warranty period shall be covered by this Limited Warranty for a period of three (3) months from the date of completion of the repair, or for the remainder of the overall Limited Warranty period, whichever is the longer.
2.
3.
4.
5.
6.
7.
If the buyer or any other party modifies any part of the Product within the Limited Warranty period without the prior written consent of Acquisitions then the Limited Warranty shall be void. Acquisitions may, at its sole discretion, decide that the Limited Warranty is void in relation to any part of the product, which has been modified.
Acquisitions must be notified of all claims under this Limited Warranty as soon as possible, but in any event not later than two (2) weeks of the claimant becoming aware of the circumstance giving rise to the claims.
No Acquisitions Distributor, retailer, employee or other third party is authorized to make any modification, extension, or addition to this Limited Warranty, whether verbal or written.
Acquisitions reserves the right to discontinue products or make substitutions, in such event, the buyer may receive a substitute product or a cash refund at Acquisition’s sole discretion, if a replacement for the product covered by this
Limited Warranty is no longer available.
Acquisitions is not responsible for damage arising from failure to follow instructions for the product’s installation, maintenance and permitted and proper use. The Limited Warranty does not cover damage caused by use with non‐
Acquisitions products or damage caused by accident, abuse, misuse, weather, fire, flood, earthquake or other external causes. Products where an Acquisitions serial number has been removed or defaced, cosmetic damage including, but not limited to, scratches. Normal fair wear and tear are also not covered.
This warranty does not cover installation of the fire into wet areas such as bathrooms or areas of very high humidity.
motion _R‐e _Service 630140_1 XFIRE_1200_GB
motion _R‐e _Service 630140_1 XFIRE_1200_GB
on
fety temperature sa of on urati nfig ct co rre
ical iance echn e t l th nce cal o than
appl
the
again atteries
from t
b
far airing
no l uni
p
too
has
is ntro ng the ote ote t re l uni ntro s mo
Change co
Try maki ccur o
The rem
The rem
•
•
•
•
If this
Change co service
Check co
r
ig erro
temperature Over
Conf
Eepron error
Temp error
ote
e rem
valve e to
th in urati nfig shorter a et e co th
g al from e hands nnel in
again
sign
th in n of airing the cha
p l wirin ptio ntro ng ng the ece h co ance e l cabl ntro co l ntro h co ouch e t lac rep or
Change batteries
Check r menu
Try maki dist
Try changi e ODS th e
heats it
cabl
tly
valve gas e
that e ODS lac
cabl
verify ble ca
ODS of ity lar
ODS e and ilot flam or rep e correc stallation. Open ctly
cabl rre co
valve
in rt sta ble
cabl pply ark ca sp
su
soft
Connect
Connect
Connect
Connect
Active
•
•
•
•
Change batteries
Change touc
Change touc
Connect
Connect
Change po
Check p
Check gas error
rt
Low battery
Button error
ured nfig co gher than e hi ent temperatur Ambi
beeps 3
beeps 3
g beep es of es of
1 lon
2 cycl
2 cycl
20 beeps
5 beeps e ianc t l uni ntro
appl
co the on
between on n mi 18 mmunicati
for ote
co ol ntr uch co to in
High temperature and rem
Loss of
es off
ortcut Sh
6 e th
ies in ter
af es off remote ter seconds switch switch
Fire
Low bat
Fire
Suppo g
usly
beeps 5
wron is
the ble ntinuo
ca
co is ound es of on, the
If LED connected way r
2 cycl
oken br or et ns
hands l butto ntro onnected isc e d
with on mmunicati uch co l cabl ntro
to
co
oken br or nnected sco e di ected nn y co e badl
ed up
oken br or oken br or
gas no nnected nnected off or sco e di sco e di upply t warm no
g
is start oken br e wron ns. t no nnected th nnected or ft so if l butto oken, br ntro t work sco
co or
di uch co nnected, es no de do ct sco rre e di
valve e to m mo y cabl
cabl tivated gra deac
Pro
Suppl
Spark attached co oken br
or
to to onse ound
No resp
Cable lose way r
Gas s
Valve cabl
ODS cabl
ODS is
ODS cabl
ODS cabl
Touch
Defective
Bad co d n’t
set t not nding hand d bu
lot set in uch pa nding e nite hand
to
does but stay on es nit
pi ion t no ignit
bu not ig m mod
mote
comma t from uch pa
comma mote does progra nite not ig does Fire
Sparks
Ignites
Ignites from re from re
Fire but no from to
Pilot ig
on ctly urati
et
) rre co e is
manual nfig shorter a
hands ote e co th
ol cabl l ntro stallation ntr al from e rem nnel in
again
sign
th in n of airing the cha
p h co h co ee in (s
touc ptio ng ng the ece lve va x to bo battery om e fr ance t
cabl l uni ntro
earth
Change batteries
Check r menu
Ensure the connected
Change touc
Try maki dist
Try changi t l uni ntro co in batteries new
Solution
•
•
•
•
•
•
Place change co
Connect ues iss nal eratio op ‐find fault
error rt r erro ROM
Suppo
Battery error
e and splay LCD di ssage
diagnos to places.
me
beeps 5
beeps 3 es of es of
Error
chart
10 beeps
2 cycl
2 cycl
fire al t l uni ntro et sign
co in
hands ote
rem of on ecepti test error rt r erro ROM
Suppo
Bad r
batteries flat or No batteries
Cause
gas orative dec 1200 llowing troubleshooting fo with XFIRE
Use the
Problem
ooting Troublesh 15.0 motion _R‐e _Service 630140_1 XFIRE_1200_GB
the
up
secure
the
is it
that
lining
so
by
until
this
facia
Do sition po
the
fire.
Lift
the
fire.
to wn into
gas
too
the
set is vice manometer.
a d again t flame
de
using
pilo assemble lly fu that the
failure
point test
ure
screw.
of the
do es
flame
.
the
indicat
on e fire
.
th
point
press laced
and
e at
drop es
attaching
it
sid
rep
for
let
plat
the s on s, and
data ur hooks
test
this as
impinges
thermocouple)
red,
the of
glow m joins/unions.
syste gas
the lace rep
and
life
not ame correctly
the ould
fl meter and ications.
completed e batteries
Connections rvice work
th
against
specif to
and hed
Gas and ment.
fo e receptacle
these
receptacle the
th
uses
move
with
above
facia
from
Facia the ure
pressure
points
pilot the
test all e mano
reduce will
press
inlet plicable se
Power
‐establis re
ap all
and motion _R‐e _Service 630140_1 XFIRE_1200_GB
Re‐establish
Check gas
Adjust gas
Remove th
Leak test
Check that
(thermocouples sh high
Re‐fit
The XFIRE facia hooks hooks are and free can be
With
14.0
13.0
e
th
ing all d media, be
reversing
Fuel mbled by
dust wn or do
‐asse re ver, Burner, Co
be
e Pilot th re should fi the
removed).
(if
replacing ps, rol Tray
ste
complete, is
Cont vious
work
pre
ble ne in
service mbly, and
wiping rtaken by unde be
ould
sh fire
surfaces.
the
and
of
Inspection: and
clean ral Clean mm
25 mm
25 mm
25 mm
25
Flue mm
25 mm
25
rts.
of
as
25mm e adjacent
Do motion
to
po u may
_R‐e
black
yo ouple.
burner
matt
_Service
order in
th
within ntial blockages
firebox
tools
thermoc
the of
blocking mm
50
components, ked into
pote or
flue
material
‐loc risk of
temperature mm 50
inside
a jects or
any
twist is r damage
above
ob
fo it
is suitable high
the on
there as
a
paint
50mm
use
the components or
component m, inspect
combustible no
flue
are
each
syste
this,
burner,
: mage to
:
the
do
on
To
da
flue
Ensure
the at there
fl
below ue
to
th
[if possible]
paint
paint.
pes or
cowl).
e diagram
below or
th e access em Syst
any
the
scra
put
up
any
not
touch
are
hav
the clean
cleaning ate
to pri appro ve access ha now or other rface. rag d you
su
a
: n with m the
[if required] ver remove
fro
dow g it
Co
soot pin
Pilot
wi
the
Thermocouple:
630140_1 XFIRE_1200_GB
Clean remove any
Paint Firebox paint. Do
Inspect Flue
If you
(including the components, and either side shown in this by
With wish to
If there
Gene
A general
Glass asse actions do
Once the
Re‐assem accessible areas
8.0
9.0
10.0
11.0
12.0
at
e
of rce.
is
to
Once uring th d
al fo at th
end
clean
tray bstanti
th t and
using
je d air.
while w from mpresse
the y and ghtl e su uir d unscre
co s ti
necessary
for
or
Remove y req couple. Ensure
an tray rmo
pipe
pulle
Valve ens embly.
and
ass ted ( h the l edge
lif be m pilot
. Pus
connection,
meta
to
gas
the
free nnect fro onnected
when
This ma micro drill
at the
visible n 3.0)
accessible.
a
th
firebox
from t) and
the
free
any has
sectio
now
using
is
as
jet
righ
and
against
the to e glass l frame
th
glass
use.
the ore emoved in (R tape. If e burner d, such
Jets: moved th ate metho pri
re
appro
burner ay, make quired.
Burner Main and placed bef ing
meta on (shown
seals
the iti
re
seal
assembly
be
or
glass
pos
which
inside
ure
tape
sec
correct the
glass
the
must
Assembly:
re ere
Pilot
tr placing the re ing an
the
gas all onnect rec to sure placed re be y can tra
control replace.
the
fi the t the
from
– lacemen
unplug
home e rep
fully
th
replaced
pushed
with
be to lt.
replaced
fe rmo
be
be t the
then uld mocouple needs couple is ay is e main
clear
tr
disc
th
disco
to
the
to
be uld
15mm
firebox s sho
removed
up
removed
the
tube
been
are
metal)
has
inside
sheet
Burner to
cover n from ured above
from
pict
Valve ol unit
clear ntr
and
co
is
screws
can
ther
sho components on
Once the
Pilot tube, thermocouple dow towards you.
If the valve. It replacemen
A click
Other separate from
When sealant wh
Check Glass
Check that damage to damage it
Ensure the is in glass is movement.
Clean all wiring the two it us
With
7.0
6.0
motion _R‐e _Service 630140_1 XFIRE_1200_GB
it
the to ured
cleaned, be to
pict as nce.
needs
screws two e applia ntrol Tray
th
Co ay from
the moving the
tr d, or
re by
control
replace
cover
the
be to
unit
: [if required]
remove
needs ay Tr
control cessary to ve the
ne
thermocouple may be
If the
Remove Control right.
First remo
o x)
care
tw the
firebo
taking of the motion _R‐e _Service
remove nt own below, e fro
this,
th
sh
do
at
as
To
w. ng grill lo
belo
upwards, ver (The
lift
thermocouple.
shown
and
and
Co
as
pilot e Pilot t Cover Pilo
the
firebox
th
the
the age
of
clean
remove
dam
side
and
to box contents pe or
need
either
access to
also
scra ere
on
side
left
jet
! re ca
stones
the
holding
the off ing
screw
lift
white
somewh
and e side th
Use extreme
burner
then
the
and moving the ht,
sliding
rig
re by
and
the to
burner
– fragile very s are
to dia (Driftwood
carefully
me aged.
them el bed fu
dam be
place ve all
upwards
shown ve the
as hand side.
ood log ll not
and ht
burner
place
completely y part.
down
an e cooled
remove or
hav
touch g to tin
fire
Contents:
630140_1 XFIRE_1200_GB
Remove Firebox
Ensure the before attemp
First remo or Coals) they wi
The driftw
Next remo screws on not to of the it in the rig in order
You will
5.0
4.0
u to
yo
to
move it.
re sheet of
glass
a
towards
to
the paper or
from
assembly
attempting ore en away
news e glass th
th n some
Lift
and
bef
you
at upo fl e hook.
it
completely eath th
towards
coverings
place low
cooled
floor rts and undern
own be mbly has me
your
sh
suppo
fra
asse
protect
glass ur hooks
to
locating e fo
glass
Assembly:
moving st be motion _R‐e
it lift
when taken
simply
be
facia,
mu
cylinders,
re
the at
supply d by
off
gas
isolate
gas
be re, the g the
fi rnin
the wer can move it.
always
the uld
re to
sho
remove To u. Care
tu
Po ne on ther
do
ei
is ion valve.
d by
work
yo
hooks.
e isolat
isolate
pack.
be intenance re attempting fo
four
towards
by
be
fire d pull
the
an
to
cooled has e facia.
‐20mm,
facia
15
attaches
e Facia:
Supply:
can
ma
battery
applianc
Gas
and
the
the at
off.
from
or
shut
service
Gas and
or
meter
Power
_Service 630140_1 XFIRE_1200_GB
Before any isolated
Remove th
Ensure the
The facia upwards handling th the batteries at the
Isolate cardboard clear the release the
Pull th
Ensure the
Remove Glass
1.0
3.0
2.0
motion _R‐e
12.0
13.0
14.0
15.0
3.0
2.0
1.0
5.0
4.0
8.0
7.0
6.0
9.0
10.0
11.0
_Service
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
electrical
and
gas
r jet
couple
burne
ermo m [if possible]
inspection and
main
[if required]
th ner
and
assembly ue syste
‐
‐
‐
‐
‐
[if required]
Tray
contents trol
assembly
supply gas wer and
Re‐establish
Re‐assemble
Replace facia connections
General clean
Inspect fl
Paint firebox
Clean bur
Clean pilot
Check glass
Remove Con
Remove firebox
Remove glass
Remove facia
Isolate po
TROUBLESHOOTING
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
‐
MBLY
RE‐ASSEMBLY
DIS‐ASSE
SERVICE
Contents:
630140_1 XFIRE_1200_GB
d trained person
NZ d, PO Box 5277 Dunedin urs 0044 (0)207 482 2949 [email protected]
es Road
DISTRIBUTED BY
London NW5 3AB tured by: Escea Lt
Email:
Tel: 24 ho manufac
24-26 Holm
Acquisitions of London
Heat engine e any service operation is carried out on this appliance.
every 12 months e be serviced is applianc It is recommended that th
Any service operation should be carried out only by a suitably qualified an
Gas supply MUST be isolated befor
SERVICE GUIDE
•
•
•
Important
Designer Balanced Flue Fires
®
X-FIRE 1200
motion _R‐e _Service 630140_1 XFIRE_1200_GB