Grass Valley SDA-1401 Operating instructions


Add to my manuals
18 Pages

advertisement

Grass Valley SDA-1401 Operating instructions | Manualzz

.

DENSITÉ series

SDA-1401

ASI DA with EQ and Reclocking

Guide to Installation and Operation

M826-9900-100

4 Jun 2009

Miranda

Technologies Inc.

3499 Douglas-B.-Floreani

St-Laurent, Québec, Canada H4S 1Y6

Tel. 514-333-1772

Fax. 514-333-9828 www.miranda.com

© 2009 Miranda Technologies Inc.

GUIDE TO INSTALLATION AND OPERATION

Safety Compliance Information

Safety Compliance

This equipment complies with:

- CSA C22.2 No. 60950-1-03 / Safety of Information Technology Equipment, Including Electrical Business Equipment.

- UL 60950-1 (1 st

- IEC 60950-1 (1

Edition) / Safety of Information Technology Equipment, Including Electrical Business Equipment. st

Edition) / Safety of Information Technology Equipment, Including Electrical Business Equipment.

CAUTION

These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Servicing should be done in a static-free environment.

Electromagnetic Compatibility

- This equipment has been tested for verification of compliance with FCC Part 15, Subpart B, class A requirements for

Digital Devices.

- This equipment complies with the requirements of:

EN 55022 Class A, Electromagnetic Emissions,

EN 61000-3-2 & -3-3, Disturbance in Supply Systems

EN 61000-4-2, -3, -4, -5, -6, -8 & -11 Electromagnetic Immunity

How to contact us:

For technical assistance, please contact the Miranda Technical support centre nearest you:

Americas

Telephone:

+1-800-224-7882 e-mail:

[email protected]

Asia

Telephone:

+852-2539-6987 e-mail:

[email protected]

Europe, Middle East, Africa, UK

Telephone:

+44 (0) 1491 820222 e-mail:

[email protected]

Telephone:

+86-10-5873-1814 e-mail:

[email protected]

Telephone:

+33 (0) 1 55 86 87 88 e-mail:

[email protected]

Visit our web site at www.miranda.com

SDA-1401

GUIDE TO INSTALLATION AND OPERATION

Table of Contents

1 SDA-1401 ASI DA with EQ and Reclocking..............................................................................1

1.1

Introduction ......................................................................................................................................... 1

1.2

Features .............................................................................................................................................. 1

1.3

Block Diagram..................................................................................................................................... 1

1.4

Front Card-edge Interface................................................................................................................... 2

2 Installation ..................................................................................................................................3

2.1

Unpacking ........................................................................................................................................... 3

2.2

Installation in the Densité frame.......................................................................................................... 3

2.3

Rear Panels and Connections ............................................................................................................ 3

2.4

Bypass Protection Relay ..................................................................................................................... 4

3 Operation ....................................................................................................................................5

3.1

Control options .................................................................................................................................... 5

3.2

Card-Edge Status LED........................................................................................................................ 5

3.3

Local control using the Densité frame control panel........................................................................... 5

3.3.1

Overview ................................................................................................................................ 5

3.3.2

Menu for local control............................................................................................................. 6

3.4

Remote control using iControl............................................................................................................. 7

3.4.1

The iControl graphic interface window................................................................................... 7

3.4.2

The Factory button ................................................................................................................. 8

3.4.3

The Status tab........................................................................................................................ 8

3.4.4

The Reclocker tab .................................................................................................................. 9

3.4.5

The Alarms tab....................................................................................................................... 9

3.4.6

The Info tab .......................................................................................................................... 11

4 Specifications ...........................................................................................................................13

ANNEX 1 – SDA-1401 Card Menu .................................................................................................14

SDA-1401

GUIDE TO INSTALLATION AND OPERATION

SDA-1401

GUIDE TO INSTALLATION AND OPERATION

1 SDA-1401 ASI DA with EQ and Reclocking

1.1 Introduction

The SDA-1401 is an ASI DA that provides up to 9 reclocked outputs with automatic equalization for up to 350 meters of cable (Belden 1694A). The amplifier also offers signal presence detection and remote reporting.

The SDA-1401 includes reclocking, offering an extra level of signal integrity in long cable length applications.

Rear panels with 4, 7 or 9 outputs are available to optimize frame real estate utilization.

Additional protection for critical applications is provided by an optional protection bypass relay available on the 1x4, 1x7 and 1x9 rear panels.

The SDA-1401 supports DVB-ASI formats and can drive up to 9 DVB-ASI outputs. The SDA-1401 also supports other compressed formats such as SMPTE-310M/DVB-SSI.

.

1.2 Features

• One DVI-ASI input

• Up to 9 DVB-ASI outputs

• Maximum flexibility offered by 3 operation modes: single 1x4, single 1x7 and single 1x9

• Automatic format detection and cable equalization

• Optional bypass relay protection

• SDI, DVB-ASI and SMPTE-310M/DVB-SSI formats supported

• Bit rate up to 270 Mbps; reclocker operates only on 270 Mbps signals

• Status LED and alarm reporting

SDA-1401 | 1

GUIDE TO INSTALLATION AND OPERATION

1.4 Front Card-edge Interface

The front card-edge of the SDA-1401 incorporates two elements:

• Status LED (see section 3.2)

• Select Button (see section 3.3)

2 | SDA-1401

SDA-1401

Select Button

Status LED

GUIDE TO INSTALLATION AND OPERATION

2 Installation

2.1 Unpacking

Make sure the following items have been shipped with your SDA-1401. If any of the following items are missing, contact your distributor or Miranda Technologies Inc.

• SDA-1401 Reclocked DA Module

• SDA-1401-XXX Rear Panel as ordered (see section 2.3)

2.2 Installation in the Densité frame

The SDA-1401 and its associated rear connector rear panel must be mounted in a DENSITÉ frame. It is not necessary to switch off the frame’s power when installing or removing the card.

• Install the rear panel with the card out of the frame, then insert the card

See the DENSITÉ Frame manual for detailed instructions for installing cards and their associated rear panels.

2.3 Rear Panels and Connections

Six rear panels are available for the SDA-1401 – see Figure 2.1 (2RU panels) and Figure 2.2 (3RU panels).

SDA-1401-SRP SDA-1401-SRP-R SDA-1401-DRP

Figure 2.1 SDA-1401 2RU rear panels

SDA-1401-DRP-R

SDA-1401 | 3

GUIDE TO INSTALLATION AND OPERATION

Panels are available for the Densité 2RU frame, and also for the Densité 3RU frame. The 3RU versions are identified by the number 3 in the size designator portion of the part number, e.g.

• SDA-1401-SRP is a 2RU version

• SDA-1401-3SRP is a 3RU version

Panels denoted by the suffix –R incorporate a bypass protection relay, as described in the next section.

2RU panels are available for the 1x4 configuration (single-width rear) and the 1x9 configuration (double-width rear)

3RU panels are available for the 1x7 configuration (single-width rear)

• 2RU panels can be mounted in the 3RU frame if required, using mounting adapter hardware.

The SDA-1401 detects the type of rear that is installed, and configures itself accordingly.

In all cases, the rear panel includes:

• ASI IN – one input on a BNC connector

• ASI OUT – the appropriate number of outputs (4, 7 or 9) on BNC connectors

Figure 2.2 SDA-1401 3RU rear panels:

Left: SDA-1401-3SRP

Right: SDA-1401-3SRP-R

2.4 Bypass Protection Relay

A bypass protection relay is mounted on the SDA-1401-SRP-R, SDA-1401-DRP-R and SDA-1401-3SRP-R rear panels.

The 1 st

output BNC is tied to the input via the non-latching relay which receives its power from the SDA-1401 card. The relay will trip upon detection of loss of card power, either through supply failure or removal of the card from the Densité frame.

The relay enables the following functions

• Bypass the electronic circuit

• Protect the output when power is lost

• Protect the output when card is removed from the frame

4 | SDA-1401

GUIDE TO INSTALLATION AND OPERATION

3 Operation

The SDA-1401 can be controlled in two different ways:

• The local control panel and its push-buttons can be used to move through a menu of parameters and to adjust parameter values (see section 3.3)

• Miranda’s iControl system can be used to access the card’s operating parameters from a remote computer, using a convenient graphical user interface (GUI). (see section 3.4)

3.2 Card-Edge Status LED

The status monitor LED is located on the front card-edge of the SDA-1401, and is visible through the front access door of the DENSITÉ frame. This multi-color LED indicates the status of the SDA-1401 by color, and by flashing/steady illumination.

The chart shows how the various error conditions that can be flagged on the SDA-1401 affect the LED status.

• If a cell is gray, the error condition cannot cause the LED to assume that status

• If more than one LED status is possible for a particular error condition, the status is configurable.

See Section 3.4.5 for details.

• The factory default status is shown by a ›

The LED will always show the most severe detected error status that it is configured to display, and in the chart error severity increases from left to right, with green representing no error/disabled, and flashing red the most severe error.

LED Status

Error Condition

No errors

No signal

Green Yellow Red

Flashing

Red

›

›

No lock (see note*)

No rear

›

›

* Note: in this case, ASI/SDI is not detected, but a DVB-SSI signal may be present

If the LED is Flashing Yellow, it means that the card is selected for local control using the Densité frame’s control panel. See Section 3.3 for details.

3.3 Local control using the Densité frame control panel

3.3.1 Overview

Push the SELECT button on the SDA-1401 card edge (see Section 1.4) to assign the local control panel to operate the SDA-1401. Use the control panel buttons to navigate through the menu, as described below.

All of the cards installed in a Densité frame are connected to the frame’s controller card, which handles all interaction between the cards and the outside world. There are no operating controls located on the cards themselves. The controller supports remote operation via its Ethernet ports, and local operation using its integrated control panel.

SDA-1401 | 5

GUIDE TO INSTALLATION AND OPERATION

The local control panel is fastened to the controller card by a hinged connector, and when installed is located in the front center of the frame, positioned in front of the power supplies. The panel consists of a display unit capable of displaying two lines of text, each 16 characters in length, and five pushbuttons.

The panel is assigned to operate any card in the frame by pushing the SELECT button on the front edge of that card.

-

+

CONTROLLER

ESC SELECT

Figure 3.1 Densité Frame local control panel

• Pushing the CONTROLLER button on the control panel selects the Controller card itself.

• The STATUS LED on the selected card flashes yellow.

The local control panel displays a menu that can be navigated using the four pushbuttons located beneath the display. The functionality of the pushbuttons is as follows:

[+] [–] Used for menu navigation and value modification

[SELECT] Gives access to the next menu level. When a parameter value is shown, pushing this button once enables modification of the value using the [+] and [–] buttons; a second push confirms the new value

[ESC] Cancels the effect of parameter value changes that have not been confirmed. Pushing [ESC] causes the parameter to revert to its former value.

Pushing [ESC] moves the user back up to the previous menu level. At the main menu, [ESC] does not exit the menu system. To exit, re-push the [SELECT] button for the card being controlled.

If no controls are operated for 30 seconds, the controller reverts to its normal standby status, and the selected card’s STATUS LED reverts to its normal operating mode.

3.3.2 Menu for local control

The SDA-1401 has operating parameters which may be adjusted locally at the controller card interface.

• Press the SELECT button on the SDA-1401 front card edge to assign the Densité frame’s local control panel to the SDA-1401

• Use the keys on the local control panel to step through the displayed menu to configure and adjust the SDA-1401

The complete menu structure is shown in the Annex to this document, beginning on page 14.

6 | SDA-1401

GUIDE TO INSTALLATION AND OPERATION

3.4 Remote control using iControl

The operation of the SDA-1401 may be controlled using Miranda’s iControl system.

• This manual describes the control panels associated with the SDA-1401 and their use.

• Please consult the iControl User’s Guide for information about setting up and operating iControl.

In iControl Navigator or iControl Websites, double-click on the SDA-1401 icon to open the control panel.

3.4.1 The iControl graphic interface window

The basic window structure for the SDA-1401 is shown in figure 3.2. The window identification line gives the card type (SDA-1401) and the slot number where the card installed in its Densité frame. On the left is a card status icon showing the overall alarm status. Its color in response to detected alarms is programmable; see section 3.4.5 on page 9.

:

Figure 3.2 SDA-1401 iControl graphic interface window

The two Status Icons show the status of specific functions:

Icon 1 – Control status

• A: Green - Remote Control via iControl

• B: Yellow - Local control using the menu

I con 2 – Input status

• A: Green – Signal OK [data rate reported in message area]

• B: Red – No signal

When an icon shows an error state, a message describing the error in more detail will appear beneath the icons in the message area .

A

B

1 2

Figure 3.3 Status icons

SDA-1401 | 7

GUIDE TO INSTALLATION AND OPERATION

• If there are multiple errors, the error messages cycle so all can be seen

• The icon whose status or error message is shown is highlighted with a mauve background

In all cases, mousing over an icon will cause a more detailed description of its current status to appear in the message area. Error message cycling will resume when the cursor is no longer over an icon.

The main section of the panel contains four tabs which give access to the various operating and status monitoring features of the SDA-1401.

• Click on a tab to access its contents.

Each of the four tabs is described individually – see sections 3.4.3 to 3.4.6.

3.4.2 The Factory button

Click the Load Factory button at the bottom of the window to reset all parameters on this SDA-1401 card to factory-defined default values.

3.4.3 The Status tab

The SDA-1401 can process the following signal formats:

• SMPTE 259M-C (270Mbps)

• DVB-ASI

• SMPTE-310M/DVB-SSI

This panel shows the status of the input signal and interface.

Signal Status: Signal OK, or an error message

ƒ When reclocker is ON, Signal OK indicates a 270 Mbps signal is present

ƒ When reclocker is Bypassed, Signal OK indicates a signal in the range 20 to 270

Mbps is present

Data Rate: The data rate detected at the input.

ƒ Only 270 Mbps with reclocker ON is specifically detected. In all other cases this window will show N/A.

Rear type: Shows the type of rear panel installed in the

Densité frame for this SDA-1401.

Figure 3.4 Status panel

8 | SDA-1401

GUIDE TO INSTALLATION AND OPERATION

3.4.4 The Reclocker tab

Use the pulldown in this panel to set the SDA-1401’s reclocker operating mode for DVB-ASI signals at 270 Mbps:

• Bypass – the input clock timing is passed through to the output

• On – the data stream is reclocked as it passes through the

SDA-1401

Reclocking is automatically bypassed for SMPTE 310M/DVI-SSI signals.

The card automatically provides equalization for up to 350 m of

Belden 1694A cable at 270 Mbps.

3.4.5 The Alarms tab

This panel allows the alarm reporting of the SDA-1401 to be configured. The panel opens in a new window when the button is clicked, and can be resized if needed.

The panel is organized in columns.

Status/Name

This contains an expandable tree listing all the alarms reported by this SDA-1401 card.

• Each alarm name includes an icon that shows its current status

The Overall alarm and GSM contribution columns contain pulldown lists that allow the level of contribution of each individual alarm to the alarm named in the column heading to be set.

• Click on the icon to see the pulldown showing the available levels

Overall Alarm

This column allows configuration of the contribution of each individual alarm to the Overall Alarm associated with this card.

The Overall Alarm is shown in the upper left corner of the iControl panel, and also appears at the bottom of the

Status/Name column.

Figure 3.5 Reclocker tab

Figure 3.6 Alarms tab

SDA-1401 | 9

GUIDE TO INSTALLATION AND OPERATION

GSM Contribution

This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated with this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external applications. The possible values for this contribution are related to the

Overall alarm contribution:

• If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any available value

Figure 3.7 Alarm Config panel

• If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to follow the Overall Alarm.

Levels associated with these alarms:

The pulldown lists may contain some or all of the following options:

The alarm makes no contribution (black icon)

The alarm is of minor importance (yellow icon)

The alarm is of major importance (orange icon)

The alarm is of critical importance (red icon)

The alarm exists but has no effect (used for text and composite alarms)

Shortcut: if you click on “Set All” beside a major heading in the Status/Name column, you will open a pulldown that lets you assign a level to all alarms in that section of the column simultaneously.

Log Events iControl maintains a log of alarm events associated with the card. The log is useful for troubleshooting and identifying event sequences. Click in the checkbox to enable logging of alarm events for each individual alarm.

At the bottom of the window are several other controls

Copy to other cards

Click this button to open a panel that allows the alarm configuration set for this card to be copied into another

SDA-1401 card.

Get alarm keys

Click this button to open a save dialog where you can save a file containing a list of all alarms on this card and their current values, along with an Alarm Key for each. The alarm keys are useful for system integration and troubleshooting.

• The file is saved in Excel.csv format

OK, Apply, Cancel

OK accepts the settings and closes the window once the card confirms that there are no errors.

Apply accepts the settings, but leaves the window open

Cancel closes the window without applying any changes, and leaves the previous settings intact.

10 | SDA-1401

GUIDE TO INSTALLATION AND OPERATION

When the SDA-1401 is included in an iControl environment, certain information about the card should be available to the iControl system. The user can enter labels and comments that will make this card easy to identify in a complex setup. This information is entered via the Info control panel. This panel also shows other information about the card.

Label: type the label that appear for this SDA-1401 when it appears in iControl applications

Short Label type the short-form label that iControl uses in some cases (8 characters)

Source ID type a descriptive name for this SDA-1401

Comments: type any desired text

Figure 3.8 Info tab

The remaining data boxes show manufacturing information about this card.

• Details…: Reports the Firmware version, service version, and panel version for this card

Figure 3.9 Details window

• Advanced…: Shows the Miranda LongID for this card. The Miranda LongID is the address of this SDA-1401 in the iControl network.

Figure 3.10 Advanced window

SDA-1401 | 11

GUIDE TO INSTALLATION AND OPERATION

• Remote System Administration – opens the Joining Locators data box, which lists remote lookup services to which this

SDA-1401 is registered.

Add: Force the iControl service for this SDA-1401 to register itself on a user-specified Jini lookup service, using the following syntax in the Input data box: jini://<ip_address> where <ip_address> is the ip address of the server running the lookup service, e.g.:

Figure 3.11 Joining Locators window

Remove: select one of the services listed in the window by clicking on it, and click Remove to delete it from the window.

12 | SDA-1401

GUIDE TO INSTALLATION AND OPERATION

Connection:

4 Specifications

INPUT

EN 50083-9 DVB-ASI (270Mbps)

DVB-SSI/SMPTE-310M

Connector

Cable Length

BNC per IEC 60169-8 Amendment 2

350 m (1150’) @ 270Mbps with Belden 1694A or equivalent

Return loss:

OUTPUTS

Number of Outputs

> 15 dB up to 270Mbps

Up to 9

EN 50083-9 DVB-ASI (270Mbps)

DVB-SSI/SMPTE-310M

Connector

Signal Level

BNC per IEC 60169-8 Amendment 2

800mV nominal

DC offset

Return Loss

Jitter

PROCESSING PERFORMANCE

0V +/-0.5V

> 15 dB up to 360Mbps

< 0.2 UI p-p (Wideband)

Signal path:

Processing delay:

10 bits

<10.5 ns (reclocking), <2.5 ns (bypass)

Power: TBD

PHYSICAL SPECIFICATIONS

Height: 3” (76mm)

5 (2RU single) or 7 (3RU single) or 10 (2RU double) BNC connectors

SDA-1401 | 13

GUIDE TO INSTALLATION AND OPERATION

ANNEX 1 – SDA-1401 Card Menu

STATUS NO SIGNAL, NO LOCK, SIGNAL 270 Mbps, SIGNAL OK

NO REAR, SRP REAR, SRP-R REAR, DRP REAR, DRP-R REAR, 3SRP REAR, 3SRP-R REAR

RECLOCKER

CONFIG ALARMS

ON, BYPASS

NO SIGNAL ALARM LEVEL

ALARM REPORT

NO LOCK

VERSION xxx

FACTORY DEFAULT [RESTORE]

Note:

* SIGNAL OK is visible only when the DA is in a Reclocker bypass mode

** NO LOCK is visible only when the reclocker is ON.

ALARM LEVEL

ALARM REPORT

[GREEN, YELLOW, RED, FLASH RED]

[NONE, GPI]

[GREEN, YELLOW, RED, FLASH RED]

[NONE, GPI]

*

**

14 | SDA-1401