STANDBY GENERATORS
8 kW - 10 kW - 14 kW
Air-Cooled Gas Engine Generator Sets
Includes:
Continuous Standby Power Rating
Model ASPDS1XXA008 (Steel - Gray) - 8 kW 60Hz
Model ASPDS1XXA010 (Steel - Gray) - 10 kW 60Hz
Model ASPDS1XXA014 (Steel - Gray) - 14 kW 60Hz
•T
wo Line LCD Digital Controller
(10 & 14 kW)
•A
utomatic Transfer Switch
with Built-In Priority Load Center
• Electronic Governor (10 & 14 kW)
• Pre-wired External Connection Box
•E
xternal Main Circuit Breaker
& System Status LED (10 & 14 kW)
• Flexible Fuel Line Connector
• Composite Mounting Pad
• Pre-wired conduits
• Natural Gas or LP Gas Operation
• UL 2200 Listed
FEATURES
¡INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of Carrier®'s success in “IMPROVING POWER BY DESIGN.” But it
doesn’t stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you
to choose Carrier® with the confidence that these systems will provide
superior performance.
¡
¡
IMPROVED ELECTRICAL TECHNOLOGY: Superior harmonics and sine
wave form produce less than 5% Total Harmonic Distortion for utility quality
power. This allows confident operation of sensitive electronic equipment and
micro-chip based appliances, such as variable speed HVAC.
TEST CRITERIA:
 PROTOTYPE TESTED
 SYSTEM TORSIONAL TESTED
 NEMA MG1-22 EVALUATION
 MOTOR STARTING ABILITY
¡SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Carrier® models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine.
¡SINGLE SOURCE SERVICE RESPONSE from Carrier®'s dealer network
provides parts and service know-how for the entire unit, from the engine
to the smallest electronic component.
¡
ARRIER® TRANSFER SWITCHES: Long life and reliability are
C
synonymous with Carrier®. One reason for this confidence is that the
Carrier® product line includes its own transfer systems and controls for
total system compatibility.
INSTALLATION
SYSTEM
UNIT
CONTROLS
TRANSFER
SWITCH
GENERATOR
ENGINE
FEATURES
Carrier® Standby Generator - 8 kW - 10 kW - 14 kW
•Generac (OHVI) Design
Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma
moly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of
engine wear, the OHVI has a significantly longer life than competitive engines.
•”Spiny-lok” cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
•Full pressure lubrication system
Superior lubrication to all vital bearings means better performance, less maintenance and
significantly longer engine life. Now featuring a 2 year/200 hour oil change interval.
•Low oil pressure shutdown system
Superior shutdown protection prevents catastrophic engine damage due to low oil.
•High temperature shutdown
Prevents damage due to overheating.
•Revolving field
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•Skewed rotor (8 & 10 kW)
Skewed stator (14 kW)
Produces a smooth output waveform for compatibility with electronic equipment.
•Displaced phase excitation
Maximizes motor starting capability.
•Automatic voltage regulation
Regulates the output voltage to ±2% prevents damaging voltage spikes.
•UL 2200 Listed
For your safety
•Fully Automatic
Transfers your vital electrical loads to the energized source of power.
•Remote Mounting
Mounts near your existing distribution panel for simple, low cost installation.
•UL Listed
For your safety
•Manual/Auto/Off switch
Selects the operating mode.
•Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 75% pick-up, of standard voltage.
•Utility interrupt delay
Prevents nuisance start-ups of the engine, setpoint approximately 10 seconds.
•Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 10 seconds.
•Engine cool-down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•Seven day exerciser
Operates engine to prevent oil seal drying and damage between power outages.
•Timed Trickle Battery charger
Maintains battery charge level to insure starting.
•Main Line Circuit Breaker
Protects generator from overload.
•Electronic governor (10 & 14 kW)
Maintains constant 60 Hz frequency.
•Weather protective enclosure
Ensures protection against mother nature. Hinged key locking roof panel for security.
Lift-out front for easy access to all routine maintenance items. Electrostatically applied
textured epoxy paint for added durability.
•Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
•Small, compact, attractive
Makes for an easy, eye appealing installation.
•Pre-wired External Connection Box
Easy Installation - Virtually all hardware included, plus step-by-step photographed Installation Guide.
•1’ Flexible Fuel Line Connector
•Composite Mounting Pad
•Pre-wired conduits
•UL Listed wire nuts
SPECIFICATIONS
GENERATOR
Rated Maximum Continuous Power Capacity (LP)
Rated Maximum Continuous Power Capacity (NG)
Rated Voltage
Rated Maximum Continuous Load Current
240 Volts
Total Harmonic Distortion
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement (not included)
Unit Weight
Dimensions (L” x W” x H”)
ENGINE
Type of Engine
Number of Cylinders
Rated Horsepower
Displacement
Cylinder Block
Valve Arrangement
Ignition System
Governor System
Compression Ratio
Starter
Oil Capacity Including Filter
Operating RPM
Fuel Consumption
Natural Gas
Model ASPDS1XXA008 (8 kW)
Model ASPDS1XXA010 (10 kW) Model ASPDS1XXA014 (14 kW)
8,000 Watts*
7,000 Watts*
120/240
10,000 Watts*
9,000 Watts*
120/240
14,000 Watts*
13,000 Watts*
120/240
33.3 LP/29.2 NG
Less than 5%
35 Amp
1
2
60Hz
1
Group 26R
12 Volts and
350 Cold-cranking
Amperes Minimum
340 Pounds
48 x 25 x 29
41.6 LP/37.5 NG
Less than 5%
45 Amp
1
2
60Hz
1
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
387 Pounds
48 x 25 x 29
58.3 LP/54.2 NG
Less than 5%
60 Amp
1
2
60Hz
1
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
439 Pounds
48 x 25 x 29
Model ASPDS1XXA008 (8 kW)
GENERAC OHVI
1
14.8 @ 3,600 rpm
410cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Mechanical
8.6:1
12 Vdc
Approx. 1.5 Qts.
3,600
Model ASPDS1XXA010 (10 kW) Model ASPDS1XXA014 (14 kW)
GENERAC OHVI V-TWIN
2
18 @ 3,600 rpm
530cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
9.5:1
12 Vdc
Approx. 1.7 Qts.
3,600
GENERAC OHVI V-TWIN
2
32 @ 3,600 rpm
992cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
9.5:1
12 Vdc
Approx. 1.7 Qts.
3,600
cu.ft./hr.
1/2 Load
77
102
156
Full Load
139
156
220
Liquid Propane
ft3/hr (gal/hr)
1/2 Load
34 (0.94)
46 (1.25)
58 (1.56)
Full Load
62 (1.68)
70 (1.93)
84 (2.30)
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 11 to 14 inches of water column for LP gas
CONTROLS
2-Line Plain Text LCD Display (10 & 14 kW)
Mode Switch
-Auto
-Off
-Manual/Test (start)
Engine Start Sequence
Engine Warm-up
Engine Cool-Down
Starter Lock-out
2.5 Amp Timed Trickle Battery Charger
Automatic Voltage Regulator w/Overvoltage Protection
Automatic Low Oil Pressure Shutdown
Overspeed Shutdown
High Temperature Shutdown
Overcrank Protection
Safety Fuse
Simple user interface for ease of operation
Automatic Start on Utility failure. 7 day exerciser
Stops unit. Power is removed. Control and charger still operate.
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration)
10 seconds
1 minute
Starter cannot re-engage until 5 sec. after engine has stopped.
Standard
Standard
Standard
Standard, 72Hz
Standard
Standard
Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power
decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Carrier® Standby Generator - 8 kW - 10 kW - 14 kW
TRANSFER SWITCH &
PRIORITY LOAD CENTER
Model ASPDS1XXA008
(8 kW)
Model ASPDS1XXA010
(10 kW)
Model ASPDS1XXA014
(14 kW)
2
100
250
2
100
250
2
100
250
75%
65%
approx. 15 sec.
Standard
Standard
26.5 x 12.5 x 7
8
5
1
1
-
75%
65%
approx. 15 sec.
Standard
Standard
26.5 x 12.5 x 7
10
3
3
1
1
-
75%
65%
approx. 15 sec.
Standard
Standard
26.5 x 12.5 x 7
14
4
4
1
1
1
10,000
10,000
No. of Poles
Current Rating (amps)
Voltage Rating (VAC)
Utility Voltage Monitor (fixed)
-Pick-up
-Dropout
Return to Utility
Exerciser weekly for 12 minutes
UL Listed
Dimensions (H” x W” x D”)
Total of Pre-wired Circuits
No. 15A 120V
No. 20A 120V
W2
No. 20A 240V
No. 30A 240V
No. 40A 240V
No. 50A 240V
Circuit Breaker Protected
Available RMS Symmetrical
H1Fault Current @ 250 Volts
H2
10,000
Mechanical Dimensions (in inches)
H1
Height
Current
No. of
Rating
Poles
H1
H2
100 UL Listed
2
26.5
29.25
W2
H2
Width
W1
W2
8.14
12.5
Depth
Transfer Switch Features
• Electrically operated,
mechanically-held contacts for
fast, positive connections.
• Rated for all classes of load,
100% equipment rated, both
inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated
or silver alloy to resist welding
and sticking.
• NEMA 1 (indoor rated)
enclosure is standard on the 100
amp switch.
7
H2
H1
Terminal Wire Ranges
ATS Rated Amps
Switch Terminal
100A 2-Pole UL W1 1 x 1/0-12
W1
H1
H2
TRANSFER
SWITCH
8KW - 17KW
(IF SUPPLIED)
Neutral Lug/Stud
1 x 3/8-16 Stud
Ground Lug
1 x 2/0-14
W2
TRANSFER
SWITCH
20KW
(IF SUPPLIED)
W1
W1
Design and specifications subject to change without notice. Dimensions shown are approximate. W2
Contact your Carrier dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
TRANSFER
SWITCH 637.6
[25.1]
8KW - 17KW
(IF SUPPLIED)
731.9
[28.8]
731.9
[28.8]
TRANSFER
SWITCH
20KW
(IF SUPPLIED)
1218
[47.9]
637.6
[25.1]
642
[25.3]
LEFT SIDE VIEW
1218
[47.9]
76.2 [3.0]
PEA GRAVEL
MINIMUM
1226
[48.3]
FRONT VIEW
Carrier Corporation • 7310 W. Morris St. Indianapolis, IN 46206 • carrier.com
©2008
Carrier Corporation All rights reserved. All specifications are subject to change without notice. Catalog No. ASPDS008-0141SS/Printed in U.S.A. 05.08, rev. 12.08
642
[25.3]
LEFT SIDE VIEW
76.2 [3.0]
PEA GRAVEL
MINIMUM
1226
[48.3]
FRONT VIEW