OWNERS MANUAL

CONVECTION PROPANE CONSTRUCTION HEATERS

Model

100R-NG

STOP

QUESTIONS?

MISSING / DAMAGED PARTS

Please do not return this product to the store.

If a part is damaged or missing, simply e-mail us at [email protected], or visit our website at http://allpro-heaters.com, or call our Customer

Service Department at (888) 619-7060.

We will be happy to assist you!

You can register your heater on line at http://allpro-heaters.com/warranty.

TABLE OF CONTENTS

HEATER SPECIFICATIONS................................................................................................................ 2

WARNINGS .................................................................................................................................. 2

OPERATING PRECAUTIONS ............................................................................................................. 3

SAFETY PRECAUTIONS .................................................................................................................... 3

ODOR FADE WARNING ...................................................................................................................... 4

OPERATING INSTRUCTIONS ............................................................................................................ 5

SERVICING ......................................................................................................................................... 5

PARTS LIST ........................................................................................................................................ 6

WARRANTY ......................................................................................................................................... 7

SERVICE CENTERS .......................................................................................................................... 7

INSTRUCTIONS FOR ORDERING PARTS ........................................................................................ 7

WARRANTY REGISTRATION ............................................................................................................. 9

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

© 2002 Scheu Products Company

Model

100R-NG

Type of Gas:

Gas Supply Pressure to regulator regulator out

Rating: 100,000 BTU/hr

HEATER SPECIFICATIONS

For use with NATURAL GAS ONLY

Maximum: 1/2 psi

4" W.C.

Ignition: Manual, piezo igntion

Model: 100R-NG

Minimum: 5" W.C.

Fuel Consumption: 100 cu. ft./hr

Fuel Orifice Port No.: 18

Fuel Orifice Port Size: #55 Drill

WARNINGS

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE

READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN

DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN,

ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT

THE MANUFACTURER.

WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS

BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED

BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE

COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN

CHEMICALS.

Scheu Products Company, Incorporated

Mail: P.O. Box 250, Upland, CA 91785

Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730

Telephone: 800-325-7057 www.scheuco.com

[email protected]

ANSI Z83.7/CGA 2.14-2000

7290M

September 2002

Page -2-

Model

100R-NG

OPERATING PRECAUTIONS

This is a natural gas, direct-fired, radiant heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.

When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.

SAFETY PRECAUTIONS

1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.

2. DO NOT modify the heater or operate a heater which has been modified from its original condition.

3. Use only natural gas.

4. Provide at least 5" W.C. but not over 1/2 psig to the heater inlet (regulator inlet).

5. Use an appropriate hose or flexible connector not over 10 ft.

(3.05m) in length.

6. Operate the heater only with the 4" W.C.regulator provided by the factory.

7. For indoor use only. Area must be well ventilated.

(Figure 1).

8. If at any time gas odor is detected, IMMEDIATELY

DISCONTINUE operation until the source of gas has been located and corrected. (See Odor Fade Warnings on page

4.)

9. Install the heater such that is is not directly exposed to water spray, rain and/or dripping water.

10. Maintain minimum clearance from normal combustible material (like paper). (Figure 2). Locate 10 ft. from canvas tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.

11. Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition.

12. Operate only on a stable, level surface.

13. Do not move, handle or service while hot or burning.

14. Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and

Handling of Liquefied Petroleum Gases ANSI/NFPA 58.

Figure 1

VENTILATION: Minimum openings required

Heater

Opening Opening near floor

Infrared ............................................................... 1 ft 2

.....................

near ceiling

1 ft 2

Convection (25-VC) ........................................... 1 ft 2

.....................

1 ft 2

Convection (All others) ...................................... 2 ft 2

.....................

2 ft 2

Radiant ................................................................ 2 ft 2

.....................

2 ft 2

Forced air (30K-125K BTU/HR) .......................... 1 ft 2

.....................

1 ft 2

Forced air (150-FAST, SPC-150T) .................... 2 ft 2

.....................

2 ft 2

Forced air (3500-FACV, SPC-350) .................... 3 ft 2

.....................

3 ft 2

Forced air (7000-FACV) .................................... 4 ft 2

.....................

4 ft 2

Figure 2

MINIMUM CLEARANCE: From normal combustible material

Clearance Infrared

Radiant

Convection Forced Air

Forced Air

7000-FACV

From floor ........................................................... 0 ft .............. 0 ft

From outlet .......................................................... 6 ft .............. 10 ft

From sides ................ 3 ft ............ 4 ft ............... 2 ft .............. 3 ft

From top ....................................... 6 ft ............... 3 ft .............. 5 ft

From front ................. 6 ft

From rear .................. 2 ft

Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.

Page -3-

Model

100R-NG

ODOR FADE WARNING

WARNING

Asphyxiation Hazard

• Do not use this heater for heating human living quarters.

• Do not use in unventilated areas.

• The flow of combustion and ventilation air must not be obstructed.

• Proper ventilation air must be provided to support the combustion air requirements of the heater being used.

• Refer to the specification section of the heater’s manual, heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the heater.

• Lack of proper ventilation air will lead to improper combustion.

• Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.

FUEL GAS ODOR

LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.

If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!

• Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.

• Get everyone out of the building and away from the area immediately.

• Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.

• Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.

• Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area.

• Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.

• FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.

ODOR FADING - NO ODOR DETECTED

• Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.

• Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.

• Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.

ATTENTION - CRITICAL POINTS TO REMEMBER!

• Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above.

• Even If you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas.

• If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.

The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade under some circumstances.

• If there is an underground leak, the movement of gas through the soil can filter the odorant.

• Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels.

• Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.

• A periodic sniff test around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY.

DO NOT WAIT!

Page -4-

MODEL

100-RANG

OPERATING INSTRUCTIONS SERVICING

PREPARING FOR OPERATION

1. Check the heater for possible shipping damage. If any is found, immediately notify your dealer.

2. Follow all of the "Safety Precautions".

3. Install plumbing to a low pressure (1/2 psig Maximum) source of natural gas, using a minimum 3/4" ID hose or flexible connector not over 10 feet in length.

4. Connect the hose to the heater at the 1/2" SAE flare fitting at the inlet.

5. Securely tighten all gas connections.

6. Open the gas cock and leak check all gas connections with a solution of soap and water. DO NOT USE A FLAME.

A hazardous condition may result if a heater is used that has been modified or is not functiong properly. When the heater is working properly:

*The flame is contained within the heater.

*The flame is essentially blue with perhaps some

yellow tipping.

*There is no strong disagreeable odor, eye burning or

other physical discomfort.

*There is no smoke or soot internal or external to the

heater.

*There are no unplanned or unexplained shut downs of

the heater.

START

1. Fully open the gas cock at the natural gas source.

2. Place control knob of the safety pilot valve in pilot position and depress the knob admitting gas to pilot. Push and release piezo button until the pilot lights, multiple tries may be necessary. Alternately place a lighted match near the

(pilot is above the valve sheild). If hose is filled with air, allow a few minutes for gas to reach the pilot.

3. When pilot lights, continue to hold the button on the safety pilot valve depressed for 30 seconds, then release.

4. If the pilot goes out, wait 5 minutes and repeat the start procedures.

5. When the pilot remains lit, turn the knob left 1/4 turn to the

"ON" position and the main burner will light.

CAUTION; INADEQUATE FUEL SUPPLY or lowering burn rate can cause sooting.

STOP

The parts list show the heater as it was constructed. Do not use a heater which is different from that shown. For this heater, the regulator must be set to supply 4" water column (W.C.) outlet pressure. If there is any uncertainty about the regulator setting, havie checked.

A heater which is not working right must be repaired, but only by a trained, experienced service person. To find the service center closest to you, visit our webside at www.scheuco.com or call

(888) 619-7060.

You may also obtain in-warranty or out-of-warranty service by taking the product to your local service center.

In-warranty products will be repaired with no charge for either parts or labor. Please include a breif statement indicating date, place of purchase, the nature of the problem and proof of purchase.

Out-of-warranty products will be repaired with a charge for parts and labor.

1. Securely close the gas cock at the gas source.

2. Depress the control knob of the pilot valve and turn clockwise to "OFF" position.

RESTART AFTER SAFETY SHUTDOWN

1. Securely close gas cock at the gas source.

2. Wait 5 minutes.

3. Restart following "Start" procedures.

Page -5-

100RNG PARTS

Item No.

Description Qty.

Item No. Description

1

2

8

9

10

11

*

3

4

5

6

7

13

14

15

0814

3095

1074

6113

1510

1072

7616

6067

1837

6137

6234

7290

1594

3683

1098

Base Assembly 1

Ballast

Valve Shield Assembly

Orifice, #55 Drill

Pilot Assembly

Manifold Assembly

Thermoelectric Valve

Spacer, 5/16" id x 1/2"

Pilot Tube Assembly

Fitting, Female Elbow

Thermocouple, 16"

Manual, Operating Instructions

Bracket, Pilot Mounting Assembly 1

Floor Shield Assembly 1

Emitter Grill 1

1

1

5

1

1

1

1

1

1

1

1

Qty.

21

22

*

24

*

16

17

18

19

20

26

27

*

*

*

3101 Louvered Emitter

3102 Pan Hood

6500 Fitting, 1/2" x Close Nipple

6259 Regulator, 4" W.C.

6125 Fitting, Male Connector

7253 Orifice Pilot

6384 Label, Natural Gas Only

4222 Bracket, Piezo

7291 Label, Model/Operating Instructions

6473 Ignitor, Piezo

3106 Leg Base, Side

3105 Leg Base, Front

6505 Fitting, Male Connector

7161 Nut, Piezo

8129 Electrode

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

Page -6-

Model

100RNG

WARRANTY

We are pleased that you have selected our product and take this opportunity to assure you that qualified service facilities are available if required. With the cooperation of independent dealers, a nationwide network of authorized servicing dealers is available for your servicing requirements.

Should your product require servicing, read the section of the manual entitled “Servicing”.

Who gets the warranty? The warranty is limited to the consumer who originally purchases the product.

What is covered? This limited warranty covers all imperfections in workmanship and material.

What is not covered? This limited warranty does not cover damage resulting from accident, misuse or abuse, lack of proper maintenance, affixing of any attachments not provided with the products, or loss of parts. IN NO EVENT SHALL

SCHEU PRODUCTS COMPANY BE LIABLE FOR ANY SPECIAL,

INCIDENTAL OR CONSEQUENTIAL DAMAGES NOR FOR ANY

DAMAGES RESULTING FROM MISUSE OR MODIFICATION OF

THIS PRODUCT.

Registering this heater within 10 days of date of purchase ensures the buyer the protection as stated on our limited warranty form.

LIMITED WARRANTY

The company warrants this product to be free from imperfections in material or workmanship, under normal and proper use in accordance with instructions of The Company, for a period of one year from the date of delivery to the buyer. The

Company, at its option, will repair or replace (f.o.b. factory,

California) products returned by the buyer to the factory,

California, transportation prepaid within said one year period and found by the Company to have imperfections in material or workmanship.

If a part is damaged or missing, simply e-mail us at [email protected], visit our website at scheuco.com, or call our Technical Support Department at (888) 619-7060.

Address any Warranty Claims to the Customer Service

Department, Scheu Products Company, Incorporated, P.O. Box

250, Upland, California 91785, or e-mail us at [email protected]. Include your name, address and telephone number and include details concerning the claim. Also, supply us with the purchase date and the name and address of the dealer from whom you purchased our product.

The foregoing is the full extent of the responsibility of the

Company. There are no other warranties, express or implied.

Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability. In no event shall the Company be liable for delay caused by imperfections, for consequential damages, or for any charges of the expense of any nature incurred without its written consent. The cost of repair or replacement shall be the exclusive remedy for any breach of warranty. There is no warranty against infringement of the like and no implied warranty arising from course of dealing or usage of trade. This warranty will not apply to any product which has been repaired or altered outside of the California factory in any respect which in our judgment affects its condition or operation.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from state to state.

SERVICE CENTERS

Scheu Products Company has over 1,000 service centers throughout North America. Call (888) 619-7060 or email [email protected] to request the service center nearest you.

Include the Make and model of your heater in any emails.

INSTRUCTIONS FOR ORDERING

PARTS

We recommend that only parts supplied by the manufacturer be used on this unit. A locally purchased part may appear to be identical, although in reality it might endanger the heater or the persons operating the heater.

The heater should be serviced only by a trained, experienced service person.

Read the section on "Servicing" before ordering parts.

For parts orders, call 888-619-7060 or e-mail us at [email protected]. Please have the model number of your heater and the replacement part number when placing your order.

Page -7-

Hand print only. Use black or blue ink pen to fill in this form. Cross or check inside the circle.

Warranty Registration

Your Information

First Name Last name

Mailing Address

-

State City Postal code

E-mail Address

Annual house hold income before tax

Age of Purchaser

<20 years

<$9,999

20-29 years

Your Preferences

Who selected the heater?

Heater will be used by?

How did you learn about our heater?

What prompted you to buy your heater?

Where will you use the heater?

Male

Individual

Female

Advertising

Store display

Other

Sudden cold weather

Replaces old model

Heater on sale

Construction project

Construction site

Shop

Other

Both

Business

Relative/friend

Previously owned heater

Warehouse

Patio

$10,000 to $19,999 $20,000 to $34,999

40-49 years

$20,000 to $34,999

50-59 years >60 years

>$50,000

30-39 years

Fold Here

Emergency backup heat

Hard to heat location

Other

In choosing your heater the following categories were:

Somewhat

Important

Important

Very

Important

Features

Portability

Price

Quality

Heat Output

Warranty

Serviceability

Fuel economy

Ease of use

Size

Fold Here

Product Information

/ /

Date of Purchase (MM/DD/YY) Cost of Heater ($)

Brand Name All Pro

-

S/N (Located on a silver label on heater)

Universal

Model Number (Located on a black and white label on heater)

National Riverside

Store Information where heater was purchased

Store Name

Type of Store

Hardware Home Center

City

Warehouse Retailer Discount Store Farm Supply

Contractor’s Supply

State

Other

SCHEU PRODUCTS COMPANY, INC

ATTN: MARKETING DEPARTMENT

8855 BAKER AVENUE

RANCHO CUCAMONGA, CA 91730

Visit our website for product information, technical support, customer service, and warranty registration at:

WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products.

Page -10-

advertisement

Related manuals