Cheetah 10K.6 SCSI Installation Guide
ST3146807LW/LC, ST373307LW/LC, ST336607LC/LW
Publication Number: 100195488, Rev. B, June 2002
Handling precautions/Electrostatic discharge protection
• Disc drives are fragile. Do not drop or jar the drive. Handle the drive only by the edges or frame.
• Drive electronics are extremely sensitive to static electricity. Keep the drive in its antistatic container until you are ready to install it. Wear a wrist strap and cable connected to ground. Discharge static from all items near or that will contact the drive. Never use an ohmmeter on any circuit boards.
• Turn off the power to the host system during installation.
• Always use forced-air ventilation when operating the drive.
• Use caution when troubleshooting a unit that has voltages present.
• Do not disassemble the drive; doing so voids the warranty.
• Return the entire drive for depot service if any part is defective.
• Do not apply pressure or attach labels to circuit board or drive top.
Electromagnetic compliance
See Safety and Regulatory Agency Specifications, p/n 75789512.
Drive characteristics
Formatted capacity
Total # of data blocks
ST3146807
LW/LC
ST373307
LW/LC
ST336607
LW/LC
146.80 Gbytes 73.40 Gbytes 36.70 Gbytes
286,749,488 143,374,744 71,687,372
(11177330h) (88BB998h) (445DCCCh)
Cylinders (user accessible) 49,855
Heads (user accessible) 8
Disc rotation ± 5%
Operating voltages
Typical operating current (amps)
10,008 RPM
+5V +12V
1.00
0.95
49,855
4
10,008 RPM
+5V
0.89
+12V
0.80
49,855
2
10,008 RPM
+5V
0.92
+12V
0.68
What you need
• Screwdriver and four 6-32 UNC drive mounting screws
• Forced-air ventilation to provide adequate drive cooling
• An unused drive power connector (not applicable to LC models)
To operate at LVD transfer rates, you may also need an LVD-capable SCSI host adapter, LVD I/O cable and active negation external terminator.
Multimode interface
This drive can operate in single-ended (SE) or low voltage differential (LVD) mode. This multimode capability provides backwards compatibility so you can use it with or without an LVD-capable host adapter. The primary benefits of LVD technology include faster transfer rates, increased allowable cable lengths, and improved device connectivity.
You can configure the drive to detect between SE and LVD modes automatically or force it to operate in SE mode only. To configure this option, see
Note. To operate at Ultra2 rates or faster in LVD mode, all devices on the same bus (cable) must be running in LVD mode. If you add any SE device to the bus, all devices on that bus operate in SE mode.
Note. Some LVD host adapters provide an LVD connector and an SE connector on the same host adapter to allow you to run SE and LVD drives concurrently at their maximum capabilities. Check your SCSI
host adapter documentation. See Figure 3.
Caution. Do not mix LVD drives on the same bus with high voltage differential (HVD) devices—drive damage may occur.
Installation instructions
1.
Set the SCSI ID
Determine which SCSI IDs are already being used in the system and then assign this disc drive a SCSI ID that isn’t already being used. Use the J6 connector located on the front of the drive to set the SCSI ID (see Figure 1).
• Most Cheetah ® 10K.6 drives are factory set with the SCSI ID set at 0. If this is the only SCSI drive in your system and there are no other SCSI devices on the daisychain, you can leave this drive’s SCSI ID set to 0 and proceed to the next step.
• The host system’s SCSI controller usually uses SCSI ID 7.
• If you have an LC model drive, the host normally sets the ID over the I/O interface, so you don’t need to worry about this step.
• If you have an LW model drive, some systems provide a cable designed to connect to the J5 jumper block on the drive to remotely set the ID. You can connect this cable to J5 and use the host-provided remote switch to set the SCSI ID. This J5 connector is not present on LC model drives.
Drive
Front
Jumper Plug
(enlarged to show detail)
Pin 1
68 Pin
SCSI I/O
Connector
Pin 1
+5V
Ground
Drive HDA
Rear
J5
Pin 1
J1
DC Power
J6
SCSI ID = 0
SCSI ID = 1
SCSI ID = 2
SCSI ID = 3
SCSI ID = 4
SCSI ID = 5
SCSI ID = 6
SCSI ID = 7
SCSI ID = 8
SCSI ID = 9
SCSI ID = 10
SCSI ID = 11
SCSI ID = 12
SCSI ID = 13
SCSI ID = 14
SCSI ID = 15
Reserved
L
E
D
R
E
S
A
3
A
2
A
1
A
0
(default)
Figure 1.
J1
SCSI ID = 0
SCSI ID = 1
SCSI ID = 2
SCSI ID = 3
SCSI ID = 4
SCSI ID = 5
SCSI ID = 6
SCSI ID = 7
SCSI ID = 8
SCSI ID = 9
SCSI ID = 10
SCSI ID = 11
SCSI ID = 12
SCSI ID = 13
SCSI ID = 14
SCSI ID = 15 not used
4P 3P 2P 1P
(default)
PCBA
A
3 A2 A1
A0
Setting the SCSI ID (the J5 block is on LW models only)
2.
Configure termination
If you are installing the drive in a system that has other SCSI devices installed, terminate only the end devices on the SCSI bus (cable). This drive does not have internal terminators or any other way of adding internal termination on the drive. You must provide external termination when termination is required. This is normally done by adding an inline terminator on the end of the cable. See Figure 3 for an illustration showing a system configuration that uses an external terminator.
• Use active (ANSI SCSI-2 Alternative 2) single-ended terminators when terminating a bus operating in single-ended mode.
• Use SPI-2-compliant active low voltage differential terminators when terminating a SCSI Ultra2 bus operating in LVD mode.
• The host adapter is normally on the end of the bus and internally terminated. You can configure your bus with another device on the end if you remove termination from the host adapter.
3.
Configure terminator power (LW model only)
Terminators have to get power from some source. The default configuration results in the drive not supplying termination power to the bus. You should normally leave this drive set at this default unless your host system requires the drive to supply termination power to the bus. To configure this drive to supply termination power to the bus, place a jumper on J2 (LW model only) pins 1 and 2 as shown in Figure 2.
4.
Connect the drive activity LED (optional)
Connect the Drive Activity LED cable to J6 pins 11 and 12 (see Figure 2), or
connect a drive ID and Drive Activity LED cable to J5, depending on host system requirements.
5.
Check the other available jumper settings
Select other options on J2 (LW model only) as illustrated in Figure 2. Do not
change these unless instructed to do so by the host system documentation.
Drive with
HDA up, PCB down, viewed from front
J2
HDA
Pin 1
Reserved Positions
Reserved
L
E
D
R
E
S
A3 A2 A1 A0
J6
Reserved
11
Remote
LED
12
Shipped with cover installed.
Do not remove.
Do not install jumpers on these four positions.
CATH
Drive Front
DC Power
Connector
SCSI I/O
Connector
J6
J2
J6 Jumper
Pin 1
End
Delay Motor Start option (valid only if the Enable Motor Start jumper is not connected)
Disable the Delay Motor Start option.
Motor start delay equal to the
SCSI ID multiplied by 12 seconds.
Motor Start option
Disable motor start (default). The drive starts according to the Delay
Motor Start option.
Enable motor start. The drive waits for the Start Unit command from the host before starting the spindle motor.
Write Protect option
Write protect = Off (enables writing).
Write protect = On (disables writing).
Parity Check option
Enable parity check of SCSI bus.
Disable parity check.
Pin 1
J2 Jumper
Single-ended I/O
A jumper here forces single-ended
I/O operation.
No jumper allows host to select either single-ended or LVD operation.
Terminator Power
Term. Power to SCSI Bus
Host adapter or other device provides term. power to external terminator.
Figure 2.
Option select jumpers (LW model only)
Pin 1
(default)
(default)
(default)
(default)
(default)
(default)
6.
Mount the drive in the host system and connect cables
Note.
LC drives are designed to be attached to a carrier or tray and inserted into the host system without I/O or power cables.
a.
Mount LW model drives to the host system’s chassis using four 6-32
UNC screws. Two mounting holes are in each side of the drive and there are four mounting holes in the bottom of the drive. Do not overtighten or force the screws. You can mount the drive in any orientation.
b.
Connect the SCSI I/O cable into the drive’s SCSI connector. Take care not to stretch or crimp this cable, and do not block the system’s cooling air flow with the cable.
Note.
For Ultra2 and faster operation, special twisted pair LVD cables are required .
c.
Connect the DC power cable to the drive. See Figure 3.
Ultra160 or Ultra2 LVD bus segment
Pin 1
(check your adapter for
Pin 1 location)
SCSI LVD/SE
SCSI SE
Host
Adapter
PCB
Twisted Pair
LVD Cable
SPI-2 compliant active LVD external terminator on the end of the cable
Caution. Formatting a drive erases all user data. Be sure that you understand this principle before formatting any hard disc drive. It is not necessary to format a drive that previously has been used to store data, unless your intention is to erase all user data.
Seagate ® is not responsible for lost user data.
Cheetah 10K.6 disc drives are designed to operate with a variety of operating systems. Please refer to your system or SCSI controller manual for information about formatting and setting up the drive. Some quick desktop system notes are provided below.
• Microsoft TM . Set the drive type in CMOS to “ Zero,” “None,” or “ No hard drive installed .” Use FDISK.EXE and FORMAT.EXE. Systems using Windows 98 or later can create one single partition (drive letter) on the drive.
• Macintosh TM . Use a third-party drive utility (most revisions of Apple’s HD
Setup utility only work with drives having special Apple firmware).
Troubleshooting
• Drive does not spin up. Check cables and all jumper settings. Make sure cable pin 1 (edge stripe) matches PCB pin 1.
• Drive spins, but no LED on/off activity. Check SCSI ID setting. Set the
ID so that each device on the SCSI chain has its own unique ID. See also the next item below. Host I/O controller is usually ID7.
• Computer does not seem to recognize the drive. Verify that the drive is enabled by the SCSI host adapter setup utility.
• FDISK does not detect the drive. Run the FDISK program located on your Windows startup diskette. Type fdisk/status to verify that your hard drive is present.
Seagate support services
For online information about Seagate products, visit www.seagate.com or e-mail your disc questions to [email protected].
If you need help installing your drive, consult your dealer first. If you need additional help, call a Seagate technical support specialist. Before calling, note your system configuration and drive model number ( ST3146807LW,
ST3146807LC, ST373307LW, ST373307LC, ST336607LW or
ST336607LC.
Africa
Australia
Austria
Belgium
+31-20-316-7222
1800-14-7201
0 800-20 12 90
0 800-74 876
Denmark
France
80 88 12 66
0 800-90 90 52
Germany 0 800-182 6831
Hong Kong 800-90-0474
New Zealand
Norway
Poland
Spain
Sweden
Switzerland
Singapore
Taiwan
0800-443988
800-113 91
00 800-311 12 38
900-98 31 24
0 207 90 073
0 800-83 84 11
800-1101-150
+886-2-2514-2237
India 1-600-33-1104 Thailand
Indonesia 001-803-1-003-2165 Turkey
Ireland
Italy
1 800-55 21 22
800-790695
001-800-11-0032165
00 800-31 92 91 40
United Kingdom 0 800-783 5177
USA/Canada/ 1-800 SEAGATE or
Malaysia 1-800-80-2335
Middle East +31-20-316-7222
Netherlands 0 800-732-4283
Latin America
Other European countries
+1-405-936-1234
+31-20-316-7222
Warranty. Contact your place of purchase or our web site (above).
Return Merchandise Authorization (RMA). Before returning the drive, verify that it is defective. Seagate Worldwide customer service centers are the only facilities authorized to service Seagate drives. Contact nearest center for return procedures and trade regulations.
Shipping the drive
Caution. Back up the data before shipping. Seagate assumes no responsibility for data lost during shipping or service. Shipping drive in an unapproved container voids the warranty. Pack the drive with original box and packing materials. Use no other materials. This prevents electrical and physical damage in transit.
Ultra SCSI SE bus segment
Figure 3.
Cable connections and external termination
7.
Format the drive
The drive has been low level formatted at the factory. You do not need to perform another low level format on this drive unless you decide to perform certain diagnostics through the host adapter. If you do decide to perform a low level format, do not abort the format as this is likely to make the drive inoperable. A low level format, with verify turned on, will typically take two hours.
Protect against power failure or other power interruptions during the format.
a.
Turn on DC power to the host system.
b.
Boot the system from a system floppy, CD, or from a previously installed hard disc drive if there is one.
c.
Format the drive.
© 2002 Seagate Technology LLC All rights reserved
Publication number: 100195488, Rev. B, June 2002, Printed in U.S.A.
Seagate, Seagate Technology, and the Seagate logo are registered trademarks of
Seagate Technology LLC. Cheetah is a registered trademark of Seagate Technology
LLC. Other product names are registered trademarks or trademarks of their owners.
Seagate reserves the right to change, without notice, product offerings or specifications.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- 146.8 GB 3.5" 10000 RPM Ultra320 SCSI
- Server/workstation HDD
- Storage drive buffer size: 8 MB
- 726 g