CSX400 AND CSX400-DC
USER’S GUIDE
Notice
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR
CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR
RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN
ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
Copyright 1997 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved
Printed in the United States of America
Part Number: 9032289 September 1997
Cabletron Systems LANVIEW , QuickSET , and SPECTRUM are registered trademarks, and QuickSTART , and CSX400 and
CSX400-DC are trademarks of Cabletron Systems, Inc.
All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
DOC Notice
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
CSX400 and CSX400-DC User’s Guide i
Notice
VCCI Notice
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology
Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
Cabletron Systems, Inc. Program License Agreement
IMPORTANT: Before utilizing this product, carefully read this License Agreement.
This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY
THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND
DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE
UNUSED PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.
Cabletron Software Program License
1.
LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.
You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron.
2.
OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program.
3.
APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.
ii CSX400 and CSX400-DC User’s Guide
Notice
Exclusion of Warranty and Disclaimer of Liability
1.
EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN
WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE
ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
2.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE
LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF
BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL,
CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE
THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR ON THE DURATION OR LIMITATION OF IMPLIED
WARRANTIES, IN SOME INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.
United States Government Restricted Rights
The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the DoD Supplement to the Federal
Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at
252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.
CSX400 and CSX400-DC User’s Guide iii
Notice
DECLARATION OF CONFORMITY
Application of Council Directive(s): 89/336/EEC
73/23/EEC
91/263/EEC
Manufacturer’s Name: Cabletron Systems, Inc.
Manufacturer’s Address: 35 Industrial Way
PO Box 5005
Rochester, NH 03867
European Representative Name: Mr. J. Solari
European Representative Address: Cabletron Systems Limited
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG13 2PZ, England
Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC
EC Directive 73/23/EEC
EC Directive 91/263/EEC
EN 55022
EN 50082-1
EN 60950
Equipment Type/Environment: Networking Equipment, for use in a Commercial or Light Industrial
Environment.
We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this notice conforms to the above directives.
Manufacturer Legal Representative in Europe
Full Name
Title
Location
Full Name
Title
Location iv CSX400 and CSX400-DC User’s Guide
Contents
Ethernet LAN Connection......................................................................... 7
Remote Management Capabilities .................................................................. 7
Firmware Data Compression.................................................................. 10
Inverse Multiplexing (IMUX) ................................................................... 10
Point-to-Point Protocol (PPP) ................................................................. 12
PAP and CHAP Security ........................................................................ 12
Bridging and Routing Protocol Filtering .................................................. 18
Simple Network Management Protocol (SNMP) .................................... 19
Software and Firmware Upgrades.......................................................... 22
CSX400 and CSX400-DC User’s Guide v
Contents
CHAPTER 3 ISDN LINE ORDERING AND CONFIGURATION
ISDN BRI Configurations ........................................................................ 25
SPIDs, Directory Numbers and Telephone Numbers ............................. 25
CHAPTER 4 PLANNING FOR CSX400 ISDN CONFIGURATION
Configuration Process and Terminology ....................................................... 29
Collect Network Information ................................................................... 30
Names and Passwords........................................................................... 30
Network Information Diagrams ............................................................... 32
Network Information Tables.................................................................... 38
Names and Passwords Example .................................................................. 47
CHAPTER 5 ETHERNET CABLING REQUIREMENTS
10BASE-T Twisted Pair Network............................................................ 50
Multimode Fiber Optic Network .............................................................. 51
Single Mode Fiber Optic Network ........................................................... 52
10BASE2 Coaxial Cable Network .......................................................... 53
Transceiver Requirements ..................................................................... 53
Installing Ethernet Port Interface Modules (EPIMs)................................ 56
Removing the CSX400 Cover ................................................................ 58
Removing the CSX400-DC Cover .......................................................... 59
Installing WAN Port Interface Modules (WPIMs) .................................... 60
vi CSX400 and CSX400-DC User’s Guide
Contents
CSX-COMP/ENCR Installation ..................................................................... 62
Tabletop and Shelf Installations ............................................................. 63
CSX400 and CSX400-DC Rackmount Installation ................................. 64
Connecting the CSX400 to the Power Source .............................................. 68
Connecting the CSX400-DC to the Power Source........................................ 69
CHAPTER 7 CSX400 CONFIGURATION WITH QuickSET
Ethernet 1 and 2 Configuration Window ................................................. 74
Wide Area T1 Configuration Window ..................................................... 80
Wide Area E1 Configuration Window ..................................................... 83
Wide Area DI Configuration Window ...................................................... 85
Wide Area Synchronous Configuration Window..................................... 88
Wide Area DDS Configuration Window .................................................. 91
Wide Area HDSL Configuration Window ................................................ 93
Wide Area Frame Relay Time Slot Configuration Window ..................... 95
Wide Area PPP Time Slot Configuration Window .................................. 96
Wide Area HDSL Time Slot Configuration Window ................................ 98
Bridging and Routing Configuration .............................................................. 99
Bridging and Routing Configuration Window .......................................... 99
Bridging and Routing (WAN Frame Type) Configuration Window........ 105
Routing Configuration Window ............................................................. 107
IP Routing Configuration ...................................................................... 108
IPX Routing Configuration .................................................................... 108
Advanced Routing Configuration Window ............................................ 111
QuickSET Pull-Down Menus....................................................................... 117
Firmware Upgrade Menu ...................................................................... 119
Advanced Configuration Menu ............................................................. 122
Compression and Congestion Window ................................................ 123
CSX400 and CSX400-DC User’s Guide vii
Contents
CHAPTER 8 GENERAL CONFIGURATION USING LOCAL MANAGEMENT
Local Management Overview...................................................................... 126
Management Agent .............................................................................. 126
Local vs. Remote Management ............................................................ 126
Local Management Screen Elements................................................... 127
Local Management Keyboard Conventions.......................................... 129
Navigating Within Local Management Screens .................................... 130
Establishing a TELNET Connection ..................................................... 131
Local Management Screen Hierarchy .................................................. 131
Accessing Local Management .................................................................... 132
Using the Menu Screens ...................................................................... 132
Main Menu Screen ............................................................................... 133
Setup Menu Screen .............................................................................. 134
Setting the System Date ....................................................................... 138
Setting the System Time ...................................................................... 138
Setting the Host IP Address ................................................................. 139
Setting the Subnet Mask ...................................................................... 139
Setting the Default Gateway ................................................................. 139
Setting the Default Interface ................................................................. 140
SNMP Community Names Screen.............................................................. 141
Community Name Access Policy.......................................................... 141
Setting SNMP Community Names ....................................................... 142
Trap Table Screen Fields ..................................................................... 143
Setting the SNMP Trap Destination...................................................... 144
Selecting a Flash Download Method .................................................... 146
viii CSX400 and CSX400-DC User’s Guide
Contents
Bridge Setup Screen Fields .................................................................. 149
Selecting a Spanning Tree Protocol ..................................................... 150
Selecting the Bridge Port Administrative Status ................................... 150
Selecting the Bridge Port Pair Administrative Status............................ 151
IP Configuration Screen Fields ............................................................. 153
IP General Config Screen..................................................................... 154
IP General Configuration Status Fields ................................................ 154
IP General Configuration Fields ........................................................... 155
Enabling the RIP Routing Protocol on a Port ....................................... 160
IPX Configuration Fields ....................................................................... 162
IPX General Configuration Screen ....................................................... 163
IPX General Configuration Status Fields .............................................. 163
IPX General Configuration Fields ......................................................... 164
IPX Routing over Frame Relay ............................................................. 167
Enabling the IPX SAP Routing Protocol on a Port ............................... 168
Enabling RIP on a Port ......................................................................... 170
WAN Physical Configuration Screen Fields ......................................... 173
WAN Interface Configuration Screen .......................................................... 174
WAN Interface Configuration Screen Fields ......................................... 174
Managing Device MIBs......................................................................... 178
MIB Navigator Command Set Overview ..................................................... 179
Conventions for MIB Navigator Commands ......................................... 180
CSX400 and CSX400-DC User’s Guide ix
Contents
Troubleshooting CSX400 Hardware ........................................................... 208
Power (PWR) LED is OFF .................................................................... 208
Processor (CPU) LED is OFF............................................................... 208
Processor (CPU) LED is RED .............................................................. 208
Collision (CLN) LED is RED ................................................................. 208
Link (LNK) LED is OFF ......................................................................... 208
Link (LNK) LED is OFF ......................................................................... 209
Link (LNK) LED is RED ........................................................................ 209
Link (LNK) LED is AMBER ................................................................... 209
Status 1 (STS1) LED is OFF ................................................................ 209
Status 1 (STS1) LED is RED ................................................................ 210
Status 1 (STS1) LED is AMBER........................................................... 211
Status 1 (STS1) LED is GREEN........................................................... 211
Status 2 (STS2) LED is OFF ................................................................ 212
Status 2 (STS 2) LED is RED WPIM-HDSL Installed in CSX400......... 213
Status 2 (STS2) LED is AMBER........................................................... 213
Status 2 (STS2) LED is GREEN........................................................... 213
Test (TST) LED is AMBER (blinking) ................................................... 214
Investigating Software Configuration Problems .......................................... 214
Connection to Device Fails During Software Configuration.................. 214
User Cannot Communicate with Remote Network Station ................... 215
APPENDIX A EPIM SPECIFICATIONS
EPIM-A and EPIM-X (AUI Port) .................................................................. 222
x CSX400 and CSX400-DC User’s Guide
Contents
EIA-530, EIA-530 ALT A, EIA-530 A, and EIA-530 A ALT A ................ 231
SPECIFICATIONS AND STANDARDS COMPLIANCE
CSX400, CSX400-DC, and WPIM Environmental Requirements............... 239
CSX400 Specifications and Compliance Standards ................................... 239
CSX400-DC Specifications and Compliance Standards............................. 240
CSX400 and CSX400-DC Regulatory Compliance..................................... 240
CSX400-DC Regulatory Compliance (Only) ............................................... 240
Individual WPIM Regulatory Compliance.................................................... 241
NETWORK INFORMATION WORKSHEETS
FCC PART 68 - USER’S INFORMATION FOR CSX400 AND CSX400-DC
CSX400 and CSX400-DC User’s Guide xi
Contents xii CSX400 and CSX400-DC User’s Guide
1
Introduction
Welcome to the Cabletron Systems CSX400 and CSX400-DC User’s Guide . This guide provides basic configuration information, hardware specifications and troubleshooting tips for the CSX400 and CSX400-DC. This guide also provides background information about 10BASE-T Ethernet
Local Area Networks (LANs) and guidelines for routing and bridging over Wide Area Networks
(WANs).
NOTE
The CSX400 and CSX400-DC have identical features and functions with the exception of their power source connection. The CSX400 connects to an ac power source and the CSX400-DC connects to a dc power source. Both the CSX400 and the
CSX400-DC are referred to as the CSX400, unless otherwise specified in this guide.
Related Documentation
Use the READ ME FIRST!
document included with the CSX400 to set up your computer before starting configuration.
Use the Cabletron Systems QuickSTART Guide (the CD insert of the QuickSET CD case) to install the CSX400.
Use the appropriate Cabletron Systems WPIM Local Management Guide to connect your CSX400 to a WAN using a TELNET connection.
How to Use This Guide
This guide along with the READ ME FIRST!
document and the QuickSTART Guide provide the necessary information to install and configure the CSX400. Read all of these documents before installing the CSX400.
This guide is organized as follows:
Chapter 1 ,
Introduction , details document conventions and provides information on getting help.
Chapter 2 ,
About the CSX400 , describes the hardware components and software protocols and
features.
CSX400 and CSX400-DC User’s Guide 1
Introduction
Chapter 3 , ISDN Line Ordering and Configuration , provides the information you need to order
ISDN service from the telephone company.
,
Planning for CSX400 ISDN Configuration , describes the router configuration
process.
,
Ethernet Cabling Requirements ,
describes the basic cabling requirements for an
Ethernet Local Area Network (LAN).
,
provides detailed installation instructions for attaching the CSX400 and
CSX400-DC to a network.
,
CSX400 Configuration with QuickSET ,
provides instructions on connecting the
CSX400 to a Wide Area Network (WAN) using Cabletron Systems QuickSET management utility.
,
General Configuration Using Local Management ,
provides instructions for configuring the CSX400 through a TELNET connection.
,
MIB Navigator , explains how to use the MIB Navigator utility.
Chapter 10 , Troubleshooting ,
provides detailed troubleshooting tips using the LANVIEW LEDs on the CSX400.
Appendix A , EPIM Specifications , provides hardware specifications and pinout information for
available Cabletron Systems Ethernet Port Interface Modules (EPIMs).
Appendix B , WPIM Cable Specifications , provides part number and connector information for
WPIMs.
Appendix C , Specifications and Standards Compliance , contains hardware specifications and
safety and compliance standards for the CSX400.
Appendix D , Network Information Worksheets , provides blank network information
worksheets.
Appendix E , FCC Part 68 - User’s Information For CSX400 and CSX400-DC , provides
instructions required to comply with FCC Rules, Part 68.
Appendix F , Glossary , defines commonly used terms.
2 CSX400 and CSX400-DC User’s Guide
Introduction
Document Conventions
The following conventions are used throughout this guide:
NOTE
Note symbol. Calls the reader’s attention to any item of information that may be of special importance.
Tip symbol. Conveys helpful hints concerning procedures or actions.
TIP
!
CAUTION
Caution symbol. Contains information essential to avoid damage to the equipment.
Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard.
WARNING
Warning symbol. Warns against an action that could result in personal injury or death.
CSX400 and CSX400-DC User’s Guide 3
Introduction
Getting Help
If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center:
Phone
Internet mail
FTP
Login
Password
(603) 332-9400 [email protected]
ctron.com (134.141.197.25) anonymous your email address
BBS
Modem setting
(603) 335-3358
8N1: 8 data bits, No parity, 1 stop bit
For additional information about Cabletron Systems or our products, visit our World Wide Web site: http://www.cabletron.com/
For technical support, select Service and Support.
Before calling the Cabletron Systems Global Call Center, have the following information ready:
• Your Cabletron Systems service contract number
• A description of the failure
• A description of any action(s) already taken to resolve the problem (e.g., changing mode switches, rebooting the unit, etc.)
• The serial and revision numbers of all involved Cabletron Systems products in the network
• A description of your network environment (layout, cable type, etc.)
• Network load and frame size at the time of trouble (if known)
• The device history (i.e., have you returned the device before, is this a recurring problem, etc.)
• Any previous Return Material Authorization (RMA) numbers
4 CSX400 and CSX400-DC User’s Guide
2
About the CSX400
The CSX400 ( Figure 1 ) is an access device that provides Ethernet Local Area Network (LAN)
connectivity via two Ethernet Port Interface Modules (EPIMs), and offers high-speed Wide Area
Network (WAN) access to remote sites via two WAN Port Interface Modules (WPIMs). The
CSX400 supports IEEE 802.1d transparent bridging, IP and IPX routing, ISDN, Dynamic Host
Configuration Protocol (DHCP), Network Address Translation (NAT) routing, and Inverse
Multiplexing (IMUX) between Ethernet LANs across a WAN.
The CSX400 operates from a standard ac power source and the CSX400-DC operates from a dc voltage source to meet all the requirements for installation into Telephone Central Office facilities.
Figure 1 The CSX400
CSX400 Hardware
This section details the CSX400 hardware capabilities.
WAN Connection
The CSX400 supports Point-to-Point Protocol (PPP) including: Link Control Protocol (LCP),
BNCP, IPCP, IPXCP, LQM, Multilink Protocol (MP) and CHAP and PAP, ISDN-BRI and Frame
Relay protocols through one of the following WAN port interface modules (WPIMs):
• The WPIM-T1 provides a T1 interface through a front panel RJ45 port and includes a built-in
Channel Service Unit/Digital Service Unit (CSU/DSU) for direct connection to a T1 line. The
WPIM-T1 provides both Full T1 or Fractional T1 using 56 or 64 Kbps Time Slots, with a total throughput of up to 1.544 Mbps.
CSX400 and CSX400-DC User’s Guide 5
About the CSX400
• The WPIM-Sync provides a synchronous serial connection of up to 2.048 Mbps to external communications equipment (e.g., a multiplexer or CSU/DSU). The WPIM-Sync uses a subminiature 26-pin connector that supports the electrical signal interfaces listed below.
Appendix B , provides complete part number and cable pinout information for the following
electrical signal interfaces:
• EIA-RS449
• V.35
• EIA-RS232D
• X.21
• EIA-RS530
• EIA-530A
• RS530 ALT A
• RS530A ALT A
• The WPIM-DDS provides a 56 Kbps or 64 Kbps Digital Data Service (DDS) connection. The
WPIM-DDS supports remote CSU diagnostic or 64 Kbps clear channel loopback and non-latching remote DSU diagnostic loopback.
• The WPIM-E1 provides an E1 interface through a front panel RJ45 port and includes a built-in
CSU/DSU for direct connection to an E1 line. The WPIM-E1 provides both Full E1 or
Fractional E1 using 56 or 64 Kbps Time Slots with a total throughput of up to 2 Mbps.
• The WPIM-DI provides a T1 interface through a front panel RJ45 port and includes a built-in
CSU/DSU for direct connection to a T1 line. The WPIM-DI provides both Full T1 or Fractional
T1 using 56 or 64 Kbps Time Slots and also provides a second Drop-and-Insert interface, which allows more than one device, such as a PBX, to share a single T1 connection.
• The WPIM-S/T provides an Integrated Services Digital Network (ISDN) 128 Kbps Basic Rate
Interface (BRI) for the CSX400. The WPIM-S/T provides an ISDN back-up link for a remote site or branch office when the main WPIM for a frame relay or leased line loses a connection or becomes disabled. An NT-1 adapter is necessary for this interface in the United States.
• The WPIM-HDSL provides a connection for users in a campus environment, or have access to local subscriber loops, who want to send their data over their existing telephone lines, that may run between floors, buildings, or other physical structures, at rates of up to 1.544Mbps. HDSL supports line lengths of up to 3, 657 meters (12,000 feet) over 24 American Wire Gauge (AWG)
Unshielded Twisted Pair (UTP) cabling.
6 CSX400 and CSX400-DC User’s Guide
About the CSX400
• The WPIM-T1/DDS provides both a T1 and DDS interface that allows you to easily switch between the two interfaces by changing the physical cabling and reconfiguring QuickSET for the desired interface. The WPIM-T1/DDS has the capabilities of both the WPIM-T1 and
WPIM-DDS.
Ethernet LAN Connection
The CSX400 provides 10 Mbps Ethernet/IEEE 802.3 support through two Cabletron Systems
Ethernet Port Interface Modules (EPIMs), which are available in a variety of media types.
Appendix A , EPIM Specifications , details the available EPIMs that can be used to configure the
CSX400 for an Ethernet connection.
FLASH EEPROMs — The CSX400 uses a FLASH Electrically Erasable Programmable
Read-Only Memory (EEPROM) that allows new and updated firmware to be downloaded in conjunction with Cabletron Systems QuickSET or any device using BootP or TFTP protocols.
LANVIEW LEDs — Cabletron Systems LANVIEW Status Monitoring and Diagnostics System is a troubleshooting tool that helps in the diagnosing of power failures, collisions, cable faults, and link problems. The LANVIEW LEDs are located on the CSX400 front panel.
RESET Button — The front panel RESET button reboots the CSX400 and initializes the processor. The RESET button also is used with the mode switches to clear NVRAM.
Remote Management Capabilities
The CSX400 can be remotely managed with any SNMP network management system including the following:
• Cabletron Systems SPECTRUM for Open Systems
• Cabletron Systems Remote SPECTRUM Portable Management Applications (SPMAs)
• Cabletron Systems QuickSET
• Cabletron Systems SPECTRUM Element Manager (SPEL)
• Third Party SNMP compliant Network Management Packages
CSX400 and CSX400-DC User’s Guide 7
About the CSX400
Optional Features
Rack Mounting Capabilities — The CSX400 can be installed in a 19-inch rack with the included mounting brackets and screws. Refer to
Chapter 6 Installation , for complete rack
mounting instructions.
Hardware Data Compression Module (CSX-COMP/ENCR) — The same industry standard
STAC Electronics Stacker LZS Compression algorithm supported by CSX400 software is made available by an optional hardware data compression module that accelerates data compression for the CSX400 over PPP and Frame Relay. Depending on the packet type and size, hardware data compression provides a minimum of 2:1 data compression, giving 3 Mbps throughput on each T-1
WPIM interface. To use the hardware data compression module, compatible equipment (such as the CSX400, CSX200, and HSIM-W6 or other vendors’ equipment which conforms to the applicable standards), must be in use at both ends of the WAN link. When the hardware data compression module is installed on the board, it automatically assumes the compression task from software. There is no configuration necessary to prioritize hardware over software compression.
CSX400 Firmware Support
The CSX400 firmware supports IEEE 802.1d bridging, and IP and IPX routing, and OSI Layer 2
Inverse Multiplexing (IMUX), which allows both WAN channels to be used as a single, high bandwidth, WAN channel. Wide Area Networking includes
Point-to-Point Protocol (PPP) ,
Frame Relay , and ISDN. Remote access is via Full or Fractional T1, E1, Synchronous, Digital
Data Service, ISDN BRI, or HDSL connections.
This device supports industry-standard protocols, security features, compression algorithms and network management tools to ensure interoperability with equipment from other vendors.
IEEE 802.3 Ethernet
The CSX400 provides a standard 802.3 Media Access Control (MAC) layer for Ethernet communications. All bridging and routing protocols are supported across the Ethernet link.
8 CSX400 and CSX400-DC User’s Guide
About the CSX400
WAN Protocols
This device supports the following WAN protocols over the WAN port:
• Point-to-Point Compression Control Protocol (CCP) as defined by RFC 1962
• Inverse Multiplexing (IMUX)
• Dynamic Host Configuration Protocol (DHCP) as defined by RFC 1541
• Network Address Translation (NAT) routing as defined by RFC 1631
• Point-to-Point Protocol (LCP) as defined by RFC 1661
• Point-to-Point Protocol (BNCP) as defined by RFC 1638
• Point-to-Point Protocol (IPCP) as defined by RFC 1332
• Point-to-Point Protocol (IPXCP) as defined by RFC 1552
• Password Authentication Protocol (PAP) and Challenge Handshake Authentication Protocol
(CHAP) under PPP as defined by RFC 1994
• Point-to-Point Protocol Line Quality Monitoring (LQM) as defined by RFC 1333
• Point-to-Point Protocol Multilink Protocol (MP) as defined by RFC 1717
• Integrated Services Digital Network (ISDN) Basic Rate Interface (BRI) as defined by Q.921/
Q.931
• Frame Relay Link Management Interface (LMI) as defined by ANSI T1.617 Annex D and ITU
Q.933 Annex A
• Frame Relay Data Encapsulation as defined by RFC 1490
• Frame Relay Data Compression Protocol (DCP) as defined by FRF.9
PPP is a data link layer industry standard WAN protocol for transferring multi-protocol data traffic over point-to-point connections. With this protocol, options such as security data compression, and network protocols can be negotiated over the connection.
Frame Relay is a packet-switching data communications protocol that statistically multiplexes many data conversations over a single transmission link. Data compression allows Frame Relay to negotiate compression over Frame Relay permanent virtual channels (PVCs).
ISDN BRI is a switched Data Link layer control protocol which uses digital signaling to place a call into an ISDN network. Once the call is made, PPP is then used to transfer data.
CSX400 and CSX400-DC User’s Guide 9
About the CSX400
Firmware Data Compression
The STAC Electronics Stacker LZS Compression algorithm provides a minimum of 2:1 firmware data compression for the CSX400 over PPP and Frame Relay. Firmware data compression is supported in software on each WAN interface for line speeds of up to 256 Kbps. per WPIM, which is equivalent to four DS0 channels. To use data compression, compatible equipment, (such as the
CSX400, CSX200, and HSIM-W6 or other vendors’ equipment which conforms to the applicable standards), must be in use at both ends of the WAN link. This firmware method of data compression is used as the default, if the hardware compression module is not installed.
Inverse Multiplexing (IMUX)
NOTE
Cabletron Systems products that support IMUX, such as the CSX400, HSIM-W6 and
HSIM-4T1, must exist on both ends of the WAN link for the IMUX function to work.
Both bridging and routing functions are disabled when using the IMUX function.
Cabletron Systems Inverse Multiplexing (IMUX) feature provides enhanced throughput for users by doing each of the following:
• The IMUX function evenly distributes a data packet stream from the LAN interface through the two WAN interfaces on the CSX400. Since the data traffic is equally shared between the two
Full T1 interfaces, each with 1.5 Mbps throughput, the total throughput over the logical link is
3 Mbps, or 6 Mbps full-duplex operation with the optional hardware compression module
(CSX-COMP/ENCR) installed in the CSX400.
• The IMUX function passes packet sequence information over the WAN using the Point-to Point
Protocol (PPP) and a WAN Encapsulated Ethernet Frame Type to support data coherency on both ends of the link.
• Data packet streams received by the WAN Interfaces on the CSX400 at the other end of the
WAN link are then recombined, ordered, and transmitted to the Ethernet 1 interface.
• The IMUX function is fully configurable using QuickSET, which is discussed in the
Bridging and Routing Configuration
section of Chapter 7 and the MIB Navigator command set in
.
10 CSX400 and CSX400-DC User’s Guide
About the CSX400
HDLC
Cabletron Systems has provided the High-level Data Link Control (HDLC) protocol which is used in conjunction with the Inverse Multiplexing (IMUX) feature and the WPIM-HDSL to conserve a user’s WAN bandwidth between two Cabletron Systems products, over a point-to-point connection. Cabletron Systems products such as the CSX400, CSX200, and HSIM-W6 must be in use on both ends of the WAN link for these functions to work. The HDLC (RAW) protocol reduces the amount of overhead information that needs to be contained within each data packet to direct it to its destination. This decreased packet overhead provides the IMUX and HDSL functions with more bandwidth to transfer user data.
DHCP and NAT
The Dynamic Host Configuration Protocol (DHCP) and Network Address Translation (NAT) method eliminates the expense of purchasing limited public IP addresses for each client on a local network, and the need to re-configure a client if it is moved to a different network.
The CSX400 acts as a DHCP server that allows individual clients (PCs, network equipment) to take turns using a range of private IP addresses (often referred to as local IP addresses), and provides optional secondary setup features for these clients on a per-port basis. The CSX400 distributes these addresses dynamically assigning a local IP address to an individual client from a range of 253 available addresses in its table on a first-come-first-served basis. This local IP address is then “leased” for a predetermined amount of time, which is configured for the particular port.
Each Ethernet port provides DHCP services for one Class C subnet and secondary setup features for individual clients that support the use of a default gateway, domain name and WINs server.
On the Wide Area Network (WAN) side, the Network Address Translation (NAT) routing method is used to enable clients assigned with local IP addresses to use the public IP address(es) of the
CSX400 WAN interface(s) to access the WAN.
NOTE
A private or “local” network is referred to as a sub network that is using private or
“local” IP addresses. An “outside” network refers to a Wide Area Network (WAN) commonly known as an Internet, an intranet is an “Internet” in use on a facility or campus where registered public IP addresses are required.
CSX400 and CSX400-DC User’s Guide 11
About the CSX400
The NAT method allows several DHCP clients on a sub network to connect to WAN clients by allowing the DHCP clients to share a single public IP address. When the CSX400 uses NAT, the
NAT method modifies the IP headers and addresses, and the selected fields in upper layer protocol headers. This is done to replace the hidden local IP addresses from the sub network with one or more public InterNic assigned IP addresses that can be sent over the outside network on the
CSX400 WAN interfaces. Once the CSX400 is assigned at least one public IP address, over 250 IP clients can share this address simultaneously using NAT. This public IP address is assigned statically by the Internet Service Provider (ISP).
Point-to-Point Protocol (PPP)
PPP is a data link layer industry standard WAN protocol for transferring multi-protocol data traffic over point-to-point connections. It is suitable for both high-speed synchronous ports as well as lower speed asynchronous dial-up ports. With this protocol, options such as security and network protocols can be negotiated over the connection.
This device supports synchronous PPP over the ISDN port. In Single Link Mode, PPP uses one
ISDN B channel for data transmission. PPP runs over each ISDN B channel for two separate conversations (split B-channel). In Multi-Link Protocol Mode, PPP simultaneously sends and receives data over two ISDN B-channels on the same connection to optimize bandwidth usage.
The STAC Electronics Stacker LZS Compression Protocol is supported over PPP providing up to
4:1 data compression.
PAP and CHAP Security
The CSX400 supports the Password Authentication Protocol (PAP) and Challenge Handshake
Authentication Protocol (CHAP) under PPP.
PAP provides verification of passwords between devices using a 2-way handshake. One device
(peer) sends the system name and password to the other device (authenticator). Then the authenticator checks the peer’s password against the configured remote peer’s password and returns acknowledgment.
CHAP is more secure than PAP as unencrypted passwords are not sent across the network. CHAP uses a 3-way handshake and supports full or half-duplex operation.
12 CSX400 and CSX400-DC User’s Guide
About the CSX400
In half-duplex operation, the authenticator device challenges the peer device by generating a
CHAP challenge, and the challenge contains an MD5 algorithm with a random number that has your encrypted password and system name. The peer device then applies a one-way hash algorithm to the random number and returns this encrypted information along with the system name in the CHAP response. The authenticator then runs the same algorithm and compares the result with the expected value. This authentication method depends upon a password or secret, known only to both ends locally.
Full-duplex operation places an additional step to the half-duplex operation that mirrors the operation discussed above for a peer to validate the authenticator. The peer device challenges the authenticator by generating a CHAP challenge, and the authenticator returns a CHAP response.
The peer device challenges the authenticator device by generating a CHAP challenge, and the challenge contains an MD5 algorithm with a random number that has your encrypted password and system name. The authenticator device then applies a one-way hash algorithm to the random number and returns this encrypted information along with the system name in the CHAP response.
The peer device then runs the same algorithm and compares the result with the expected value.
This authentication method depends upon a password or secret, known only to both ends locally.
LQM
Link Quality Monitoring (LQM) is a link control mechanism used with PPP to determine when and how often a link is dropping data in units of packets and octets. Link Quality Monitoring accomplishes this by providing Link-Quality-Reports to determine if the quality of the link is adequate for operation. Link Quality Monitoring provides separate measurements for both incoming and outgoing packets that are communicated to both ends of the link. The PPP LQM mechanism carefully defines the Link-Quality-Report packet formats, and specifies reference points for all data transmission and reception measurements. The LQM implementation maintains successfully received packet and octet counts, and periodically transmits this information to its peer using Link-Quality-Report packets.
Multilink Protocol
Multilink Protocol (MP) is an extension of PPP that controls the way frames are transferred across several links whenever a single link is not sufficient to meet the requirements of your present traffic load. Multilink Protocol establishes several simultaneous links between two end points over switched circuits (dial-up lines) in an ISDN network, and dynamically adjusts the bandwidth demands between available links to maintain an effective data transfer.
CSX400 and CSX400-DC User’s Guide 13
About the CSX400
ISDN
ISDN provides an inexpensive switched digital access to remote sites. The ISDN BRI standard provides for two high speed 64 Kbps bearer (B) channels used for voice or data connections and one 16 Kbps signaling data (D) channel used for call setup, signaling and other information. ISDN allows all types of information to be transmitted including voice, data, fax and video. Multiple devices can be linked to a single ISDN connection, each having their own telephone number. Two or more channels can be combined into a single larger transmission pipe offering variable transmission speeds.
The CSX400 supports one ISDN BRI line and either or both of the B channels for transferring data. If the two B channels are used for separate connections, each provides up to 64 Kbps transfer rates. Both channels can be used together to provide uncompressed data transfer at up to 128 Kbps.
The CSX400 can also transfer compressed data at up to 512 Kbps.
A Network Terminator device (NT1) provides the interface between ISDN terminal (router) equipment and the ISDN service provider. In the U.S., the NT1 is provided by the customer; outside the U.S., the NT1 is provided by the ISDN service provider. The CSX400 supports the
WPIM-S/T by providing an S/T interface that requires an external NT1.
Telephone Switch Support
The following telephone switch types are supported within the U.S.:
•
•
AT&T 5ESS with Custom Software
•
Outside of the U.S. the following switch types are supported:
• NET3 (European ISDN)
• NET3SW (European Swiss-variant)
• NTT (Nippon Telegraph and Telephone)
• KDD (Kokusai Denshin Denwa Co., Ltd.)
• French Delta (VN4) switches
14 CSX400 and CSX400-DC User’s Guide
About the CSX400
ISDN Back-up
The ISDN back-up feature provides a back-up link for a remote site or branch office when one or more primary WAN interfaces for a frame relay circuit or a nailed-up PPP connection fails. The
WPIM-S/T serves as the backup medium for this primary connection. The WPIM-S/T uses the
ISDN interfaces to back-up any primary interfaces which have been configured for ISDN back-up.
Time to Connect, Time to Disconnect, Connect Retries, Back-up Override, Input Idle Time-out and Output Idle Time-out, are the six back-up parameters used to manage the ISDN Back-up feature on the CSX400, and are described as follows:
Time to Connect — Time to Connect allows you to configure the amount of seconds the primary interface can be in a failed state, before attempting to switch over to the back-up interface.
Time to Disconnect — Time to Disconnect allows you to configure the amount of seconds the restored primary interface must remain connected, before attempting to switch over from the back-up interface.
Connect Retries — Connect Retries allows you to configure the number of tries to restore the back-up interface, before giving up.
Backup Override — Backup Override forces the back-up interface to remain connected, and does not allow the back-up interface to switch back to the primary interface, even if the primary interface is restored.
Input Idle Time-out — Input Idle Time-out allows you to determine the amount of time necessary for data packets to be received, before the interface is automatically disconnected.
Output Idle Time-out — Output Idle Time-out allows you to determine the amount of time necessary for data packets to be transmitted, before the interface is automatically disconnected.
CSX400 and CSX400-DC User’s Guide 15
About the CSX400
HDSL
High-bit rate Digital Subscriber Line (HDSL) technology uses existing copper twisted pair cables designed for conventional analog voice transmission from a telephone carrier servicing area as a low-cost alternative to the quality and speed of fiber optic cables, and provides high-speed full-duplex digital transmission links of up to 1.544 Mbps. The WPIM-HDSL is easy to install in your network over existing telephone lines, and it is a portable investment if a business, or individual user plans to relocate.
HDSL is a direct connection technology that allows connections to be made for distances of up to
12,000 feet over 24 American Wire Gauge (AWG) unconditioned Twisted Pair wire. To obtain the
Full T1 line Rate of 1.544 Mbps, two wire pairs are necessary (four wires). If one pair of wires is used (two wires), then data rates of 772 Kbps are supported, which is equivalent to one-half of a
T1 line.
Bridging and Routing
Bridging — Bridging connects two or more separate networks together. The bridge examines a portion of each network frame called the header. This header contains control information for the frame. The bridge compares the destination address of the frame to a table of source addresses
(bridges dynamically learn the physical location of devices by logging the source addresses of each frame and the bridge port the frame was received on in the source address table). In transparent bridging, the decision to forward the frame is based on this comparison. If the address indicates that the sending station and the destination station are on the same side of the bridge, the frame is not forwarded across the bridge. If the addresses do not indicate that, the bridge forwards the broadcast frame across the bridge to the other network(s).
Bridging allows frames to be sent to all destinations regardless of the network protocols used. It also allows protocols that cannot be routed (such as NETBIOS) to be forwarded, and optimizes internetwork capacity by localizing traffic on LAN segments. A bridge extends the physical reach of networks beyond the limits of each LAN segment. Filters can be used to increase network security in bridged networks, and restrict message forwarding by using user-built address tables (non-transparent bridging).
16 CSX400 and CSX400-DC User’s Guide
About the CSX400
Routing — Routing provides a way to transfer user data from source to destination over different
LAN and WAN links using one or more network protocol formats. Routing relies on routing address tables to determine the best path for each packet. Routing tables can be seeded (i.e., addresses for remote destinations are placed in the table along with network address masks and a metric for path latency). Routing tables are also built dynamically (i.e., the location of remote stations, hosts and networks are updated through inter-router protocols). Routing helps to increase network capacity by localizing traffic on LAN segments and broadcasts that would result from bridged traffic. It also provides security by isolating traffic on segmented LANs. Routing extends the world-wide reach of networks.
CSX400 Bridging and Routing — The CSX400 can operate as a bridge, a router, or both. The
CSX400 operates as a router for network protocols that are supported when routing is enabled and operates as a bridge when bridging is enabled. When both bridging and routing are enabled, routing takes precedence over bridging; i.e., the CSX400 uses the protocol address information of the packet to route the packet to the correct destination. However, if the protocol is not supported, the CSX400 operates as a bridge and uses the MAC address information to send the packet.
Operation of the CSX400 is influenced by routing and bridging controls and filters set during
CSX400 configuration. General IP routing, and routing or bridging from specific remote routers are controls set during the configuration process.
IEEE 802.1d Bridging — The CSX400 supports the IEEE 802.1d standard for LAN to LAN bridging. Bridging is provided over PPP and Frame Relay as well as adjacent LAN ports. The bridging software uses transparent bridging. When the CSX400 is configured as a bridge, the unit bridges data packets to the destination, regardless of the network protocols used.
The CSX400 uses the Spanning Tree Algorithm to provide bridging redundancy while preventing data loops and duplicate data. This is a self-learning bridge, i.e., the bridge builds and updates an address table with each MAC source address and associated information when the packets are received.
IP Routing — IP routing support provides the ability to process
frames at the network layer for routing. IP routing support includes the Routing Information Protocol (RIP) that allows the exchange of routing information on a TCP/IP network. The CSX400 receives and broadcasts
RIP messages to adjacent routers and workstations.
IPX Routing — Internet Packet Exchange (IPX) routing support provides the ability to process
Novell proprietary frames at the network layer for routing. IPX routing support includes both
Routing Information Protocol (RIP) and Service Advertising Protocol (SAP) that allows the exchange of routing information on a Novell NetWare network. The SAP provides routers and servers containing SAP agents with a means of exchanging internetwork service information.
CSX400 and CSX400-DC User’s Guide 17
About the CSX400
Bridging and Routing Protocol Filtering
Filtering is used to allow efficient usage of network resources and provide security for your network and hosts.
IP Internet Firewall — The CSX400 supports IP Internet Firewall filtering to prevent unauthorized access to your system and network resources from the Internet or a corporate
Intranet. Security can be configured to permit or deny IP traffic. The security is established by configuring IP access filters, which are based on source IP address, source mask, destination IP address, destination mask, protocol type, and application port identifiers for both Transmission
Control Protocol (TCP) and User Datagram Protocol (UDP) protocols. These IP access filters allow individual IP source and destination pair filtering as well as IP address ranges and wild carding to match any IP address. These Firewall filters can be defined to allow inbound only, outbound only, or bi-directional IP communication up to the UDP and TCP application port level.
Firewall access filters provide a lot of flexibility to establish a powerful IP security barrier. The
CSX400 supports the IP Access Control (from the ctip-mib) Internet Firewall Filter.
Bridge Filtering — Bridge filtering allows a network administrator to control the flow of packets across the CSX400. Bridge filtering can be used to “deny” or “allow” packets based on a “matched pattern” using a specified position and hexadecimal content within the packet. This enables restricting or forwarding of messages based on address, protocol, or data content. Common uses include preventing access to remote networks, controlling unauthorized access to the local network, and limiting unnecessary traffic.
The CSX400 supports the following Bridge Filters:
• dot1dStatic Filters (IETF RFC1493)
• Ethernet Special Filtering Database (from the ctbridge-mib)
System Passwords
System passwords allow you to control access to the CSX400 by establishing three passwords.
Each password provides varying levels of access to the CSX400. The default password for each access level is pre-set to public. If you do not wish to establish a password, press ENTER, the default password is automatically selected.
The following definitions explain each of the three levels of access: read-only — passwords.
This access level allows reading of device parameters not including system
18 CSX400 and CSX400-DC User’s Guide
About the CSX400 read-write — This access level allows editing of some device configuration parameters not including changing system passwords.
super-user — This access level allows full management privileges. At this level you must access the CSX400 to run QuickSET.
Simple Network Management Protocol (SNMP)
The CSX400 provides SNMP agent support for the following: standard and Enterprise Specific
Management Information Bases (MIBs), and support for standard and Enterprise Specific SNMP
Traps. SNMP is also used internally for configuration of the CSX400. The active SNMP agent within the CSX400 accepts SNMP requests for status, statistics and configuration updates.
Communication with the SNMP agent occurs over the LAN or WAN connection. Any management application using SNMP over
has access to the local SNMP agent.
SNMP MIB Support
SNMP MIBs are databases of objects used for managing and determining the status and configuration of an SNMP compliant device.
The following SNMP MIBs are supported by the CSX400:
• MIB IIRFC1213
• RMON MIBRFC1271
• DS1 and E1 MIBRFC1406(Digital Signal Level 1 [T1/E1 interface types])
• IETF Bridge MIBRFC1493
• IP Forwarding MIB RFC1354
• PPP LCP MIBRFC1471(Point-to-Point Protocol, Link Control Protocol)
• PPP IPCP MIBRFC1473(IP Control Protocol)
• PPP BNCP MIBRFC1474(Bridge Network Control Protocol)
• IPXCP MIBRFC1552
• Frame Relay DTE MIBRFC1490
• Security MIBRFC1472(CCP, PAP, and CHAP)
• RS-232 MIBRFC1317
• LQM MIBRFC1989
• PPP MP MIBRFC1990
CSX400 and CSX400-DC User’s Guide 19
About the CSX400
Cabletron Enterprise MIBs
Cabletron Enterprise MIBs include the following: CTWAN-MIB, CTMIB2-EXT-MIB,
CTDOWNLOAD-MIB, CTBRIDGE-MIB, RREV-4-MIB, CTROUTER-MIB, CTFAULT-MIB,
CTIP-MIB, CHASSIS-MIB, CTNETDIAG-MIB, IP-MIB, IPX-MIB, CTDEFAULT-MIB,
CTNAT-MIB.TXT, CTDHCP-MIB.TXT, CTWAN-IMUX-MIB,
CTISDN-DIALCONTROL-MIB, CTISDN-DCHANNEL-MIB, and
CTISDN-REMOTEPROFILE-MIB.
SNMP Trap Support
SNMP Traps are notifications of network events sent by an SNMP compliant device to an SNMP management station.
The following SNMP Traps are supported by the CSX400:
IETF Standard Traps:
• Warm Start Trap Type Code #1RFC1214
• Bridge New Root TrapType Code #1RFC1493
• Bridge Topology Change TrapType Code #2RFC1493
Cabletron Enterprise Traps:
• Port Segmented TrapType Code #257(0x101)rrev4-mib
• Port Operational TrapType Code #258(0x102)rrev4-mib
• Port Link Up TrapType Code #259(0x103)rrev4-mib
• Port Link Down TrapType Code #260(0x106)rrev4-mib
• Environmental Temperature Hot TrapType Code #282(0x11A)rrev4-mib
• Environmental Temperature Normal TrapType Code #284(0x11C)rrev4-mib
• IP Event Log Change TrapType Code #1280(0x500)ctip-mib
The following is a list of IP Events that are logged and create the IP Event Log Change Trap.
• IP Routing has been disabled on interface #
• IP Routing has been enabled on interface #
• IP Forwarding has been enabled on interface #
• IP MTU size has been changed on interface #
20 CSX400 and CSX400-DC User’s Guide
About the CSX400
• IP Framing Type has been changed on interface #
• IP has detected Link UP on interface #
• IP has detected Link DOWN on interface #
• IP Primary address has been changed on interface #
• IP Secondary address has been changed on interface #
• IP Access Control Lists have been enabled on interface #
• IP Access Control Lists have been disabled on interface #
• IP has detected Port UP (WAN devices only)
• IP has detected Port DOWN (WAN devices only)
• IP Proxy ARP has been disabled on interface #
• IP Proxy ARP has been enabled on interface #
• IP RIP has been enabled on interface #
• IP RIP has been disabled on interface #
• IPX Event Log Change Trap Type Code #1281(0x501) ctipx-mib
The following is a list of IPX Events that are logged and create the IPX Event Log Change Trap.
• IPX Routing has been disabled on interface #
• IPX Routing has been enabled on interface #
• IPX Forwarding has been enabled on interface #
• IPX MTU size has been changed on interface #
• IPX Framing Type has been changed on interface #
• IPX has detected Link UP on interface #
• IPX has detected Link DOWN on interface #
• IPX Primary address has been changed on interface #
• IPX Access Control Lists have been enabled on interface #
• IPX Access Control Lists have been disabled on interface #
• IPX has detected Port UP (WAN devices only)
CSX400 and CSX400-DC User’s Guide 21
About the CSX400
• IPX has detected Port DOWN (WAN devices only)
• IPX RIP has been enabled on interface #
• IPX RIP has been disabled on interface #
• IPX SAP has been enabled on interface #
• IPX SAP has been disabled on interface #
Software and Firmware Upgrades
Software and Firmware upgrades can be performed remotely through the Windows-based
QuickSET utility application. Refer to
for QuickSET instructions. QuickSET allows you to retrieve or upgrade the firmware, software, and configuration files from its Firmware
Upgrade menu by selecting the
TFTP/BootP Services window to access a TFTP (Trivial File
Transfer Protocol) server.
22 CSX400 and CSX400-DC User’s Guide
3
ISDN Line Ordering and Configuration
This chapter provides ISDN BRI (Basic Rate Interface) line ordering and configuration information. It contains the following sections:
•
•
•
•
SPIDs, Directory Numbers and Telephone Numbers
•
Read the first section in this chapter for an overview of the steps required to order ISDN service from your service provider (telephone company). The rest of the chapter details the information that the service provider needs to give you, and which you need to give to the service provider.
Arranging ISDN Service
The service provider requires certain information about the capabilities of the CSX400. You must give the service provider the required switch settings (parameters) for the provider’s central office switch. Consult with your service provider at least two months before you require the installation and use of the ISDN service.
Complete the following steps to arrange your ISDN service:
1.
Contact the service provider and determine what type of ISDN central office switches are available (see
Telephone Switch Support in this chapter).
2.
Supply the service provider with the provisioning information for their switch type to enable proper configuration of the ISDN line (see
in this chapter).
3.
Once the ISDN line is installed, ensure that the service provider supplies you with the following information:
• ISDN telephone numbers
• ISDN Service Profile Identifier numbers (SPIDs) and/or Directory Numbers (DNs) (see
SPIDs, Directory Numbers and Telephone Numbers in this chapter).
CSX400 and CSX400-DC User’s Guide 23
ISDN Line Ordering and Configuration
Telephone Switch Support
Your telephone company may offer a variety of ISDN switch types. You must contact your service provider and find out which type of ISDN service is available.
The following switch types are currently supported by the CSX400 within the U.S.:
•
•
AT&T 5ESS with Custom Software
•
Outside of the U.S. the following switch types are currently supported:
• NET3 (European ISDN)
• NET3SW (European Swiss-variant)
• NTT (Nippon Telegraph and Telephone)
• KDD (Kokusai Denshin Denwa Co., Ltd.)
• French Delta (VN4) switches
ISDN BRI Line Configuration
You need to order one Basic Rate Interface (BRI) ISDN line from your service provider. The Basic
Rate Interface ISDN line provides two full duplex 64 (Kbps) B channels used for voice, data, fax, etc. and one full duplex 16 Kbps channel used for signaling. Each B channel can be used for a call; i.e., two calls can occur at the same time. Services vary from individual service providers.
NOTE
Full 64 Kbps for each channel (called clear channel) may not be available across the entire communications link. Today, many providers still use in-band signaling
(the 8 Kbps signaling is taken from the B channel bandwidth) so that you may only achieve a 56 Kbps channel speed.
The service provider requires some information from you about your configuration. You must provide your service provider with the required switch settings for the provider’s telephone switch
(see Telephone Switch Parameters in this chapter). Consult with your service provider at least
two months before requiring the installation and use of the ISDN service.
24 CSX400 and CSX400-DC User’s Guide
ISDN Line Ordering and Configuration
In the U.S. and Canada, Network Terminator equipment (NT1) is required to provide an interface between the CSX400 and the ISDN line. The NT1 offers conversion between the two-wire twisted pair (U-loop interface) used by telephone companies and the four-wire terminal equipment (S/T
Interface) as well as line-testing capabilities. External Network Terminator equipment comes with a power supply (built-in or external).
In Europe and Japan, the telephone company provides the NT1 and offers end-users the S/T interface. The S refers to a connection between customer equipment in some ISDN configurations when a PBX is present. The T refers to the connection between the NT1 device and the CSX400.
The ISDN pairs are the same wires that exist for analog telephone service. In most cases, the same wires can be used for the ISDN line. The EIA/TIA standard for wiring is Unshielded Twisted Pair
(UTP) cable, Category 3 or above, 24 AWG (American Wire Gauge). The standard also recommends using 8-position RJ45 jacks for new ISDN service installation. No special conditioning is required; in some cases, conditioning must be removed.
ISDN BRI Configurations
ISDN BRI lines can be configured in point-to-point and multi-point configurations. With a point-to-point configuration, only one device is connected to the ISDN line. With a multi-point configuration, it is possible to have up to 8 devices (telephones, faxes, routers, etc.) connected to the line.
Since the ISDN BRI line is used for a high speed LAN-to-LAN link, you must ensure that additional devices connected to the S/T interface allow sufficient access for the bandwidth requirements of the CSX400.
SPIDs, Directory Numbers and Telephone Numbers
The service provider gives you up to three sets of numbers for identifying the ISDN line and devices. You may be assigned none, one or two Service Profile Identifier numbers (SPIDs) or
Directory Numbers (DNs) depending on the service provider and country.
Phone Numbers
Numbers used for others to dial into the ISDN B channels on your ISDN line (similar to analog line phone numbers).
Directory Numbers
Address assigned by the ISDN service provider for each device operating on the line. This number can be similar to the phone number. The Directory Number is not generally implemented outside the U.S.
CSX400 and CSX400-DC User’s Guide 25
ISDN Line Ordering and Configuration
Service Profile Identifiers
SPIDs, also assigned by the ISDN service provider, identify the services and features that the telephone company switch provides to the ISDN device. Commonly implemented in the U.S. and
Canada, the SPID is often derived from the directory number, combined in a series with other digits. SPIDs are not generally implemented outside the U.S. and Canada.
Telephone Switch Parameters
Once you have contacted your service provider and learned the type of ISDN switch being used, refer to
Table 3 . You must supply the appropriate provisioning information
to the service provider to ensure proper configuration of the ISDN line.
NOTE
National ISDN 1 (NI-1) is a specification released by Bellcore outlining a basic set of
ISDN services used for standardization by equipment vendors.
Table 1 National ISDN 1 (NI-1)
ISDN Switch Parameters
B1
B2
D
Multipoint
Terminal Type
Display
TEI
MTERM
MAXB CHL
ACT USR
CSD
CSD CHL
Value
Y
2
1
2
Any
Circuit Switched Data & Voice
Circuit Switched Data & Voice
Signaling Only
Yes
A
Off
Dynamic
26 CSX400 and CSX400-DC User’s Guide
ISDN Line Ordering and Configuration
Table 1 National ISDN 1 (NI-1) (Continued)
ISDN Switch Parameters Value
CSD Limit
CA Pref
EKTS
Nail Up
2
1
No
None
Table 2 AT&T 5ESS with Custom Software
ISDN Switch Parameters Value
B1
B2
D
Multipoint
Terminal Type
Display
TEI
MTERM
MAXB CHL
ACT USR
CSD
CSD CHL
CSD Limit
CA Pref
Nail Up
2
Y
2
Any
2
1
None
Circuit Switched Data & Voice
Circuit Switched Data & Voice
Signaling Only
No
A
Off
Dynamic
1
CSX400 and CSX400-DC User’s Guide 27
ISDN Line Ordering and Configuration
ISDN Switch Parameters
Table 3 DMS-100
Value
B1
B2
D
EKTS
Ringing Indicator
Release Key
PVER
TEI
MAXKEYS
Nail Up
Circuit Switched Data & Voice
Circuit Switched Data & Voice
Signaling Only
No
No
No
01
Dynamic
64
None
28 CSX400 and CSX400-DC User’s Guide
4
Planning for CSX400 ISDN Configuration
This chapter explains the CSX400 ISDN-BRI configuration process and terminology. It also describes the information that is required for configuration.
Configuration Process and Terminology
During configuration, you specify information identifying the CSX400 and define the LAN and
WAN connections of the CSX400. All of the remote routers to which this device may connect are added to a database called the remote router database that resides in the CSX400. Each remote router entry in the database defines the connection parameters, security features, route addressing
and bridging function for the remote router (see the example in Figure 2 ). Routing and bridging
are controlled by specific remote router entry information as well as general controls that are set after all other information is configured.
ROUTER A
REMOTE ROUTERS
ROUTER B
CSX400
SYSTEM SETTINGS
ISDN SETTINGS
ETHERNET LAN SETTINGS
REMOTE ROUTER DATABASE
REMOTE ROUTER B
REMOTE ROUTER C
ISDN
ROUTER C
ROUTER D
Figure 2 Router A Configuration
CSX400 and CSX400-DC User’s Guide 29
Planning for CSX400 ISDN Configuration
Collect Network Information
Before you begin, you need to obtain information about the network to which you are adding the
CSX400. Some of the information is obtained from your central site or remote site network administrator. Other information is obtained from your ISDN service provider.
You must define the name and security password of the CSX400, ISDN line information and the
Ethernet LAN IP and/or IPX address. You need to identify all of the remote routers and their routing and bridging capability, ISDN phone numbers, addressing and security information. You also need to decide whether you will use Internet Firewall Filtering if you are using IP routing. The following sections contain diagrams and tables to help you gather and organize the information.
Names and Passwords
You must choose a name for the CSX400 and the authentication password, both of which are used by a remote site to authenticate the target router. For each remote router, you must have the router name and its authentication password which is used by the CSX400 to authenticate the remote
router. The name and password are used in both PAP and CHAP authentication. Figure 3 shows
how this information is used.
PAP AUTHENTICATION
NEW YORK
NEW YORK AND XYZ
CHICAGO
SYSTEM NAME = NEW YORK
SYSTEM PASSWORD = XYZ
REMOTE ROUTER DATABASE
REMOTE = CHICAGO
PASSWORD = ABC
ACCEPTED/REJECTED
Figure 3 PAP Authentication
SYSTEM NAME = CHICAGO
SYSTEM PASSWORD = ABC
REMOTE ROUTER DATABASE
REMOTE = NEW YORK
PASSWORD = XYZ
30 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
ISDN Line Information
You need to know the telephone switch type and phone numbers associated with the ISDN line.
The telephone switch types supported are listed in
Telephone Switch Support . The service
provider gives you up to three sets of numbers for identifying the ISDN line and attached devices.
You may be assigned none, one or two SPIDs or DNs and this varies by service provider and country.
Phone Numbers — Numbers used for others to dial into the ISDN B channels on your ISDN line
(similar to analog line phone numbers).
Directory Numbers — Address assigned by the ISDN service provider for each device operating on the line. This number can be similar to the phone number. The Directory Number is not generally implemented outside the U.S.
Service Profile Identifications — SPIDs, also assigned by the ISDN service provider, identify the services and features that the switch provides to the ISDN device. Commonly implemented in the U.S. and Canada, the SPID is often derived from the directory number, combined in a series with other digits as shown in the example in
Figure 4 . SPIDs are not generally implemented
outside of the U.S. and Canada.
PHONE NUMBER 555-1001 ISDN B CHANNEL
CENTRAL OFFICE SWITCH
CSX400
PHONE NUMBER 555-1002 ISDN B CHANNEL
EXAMPLES:
NORTHERN TELECOM DMS-100 SWITCH
DNs = 5551001, 5551002
SPIDs = 41555510011, 41555510022 OR
415555100101, 415555100202
AT&T 5ESS
POINT-POINT MODE: NO SPIDs
MULTI-POINT MODE: SPID = 0155510010 OR
SPIDs = 01555100100, 01555100200
Figure 4 Service Profile Identifications (SPIDs)
Refer to Chapter 3, ISDN Line Ordering and Configuration, for further information about
ISDN configurations and line ordering.
CSX400 and CSX400-DC User’s Guide 31
Planning for CSX400 ISDN Configuration
Network Information Diagrams
It is helpful to draw a diagram including all locations, addresses, router names, etc. This section includes diagrams needed to configure the CSX400. You may need different addressing information depending on whether you are configuring IP routing and/or NetWare IPX routing.
NOTE
The diagrams show the information required to configure only the CSX400. If you need to configure both ends of the WAN link, you should label all information for the network.
TCP/IP Routing — An IP address and subnet mask are required for the Ethernet LAN for the router connection. Each remote router ISDN WAN link may have local and remote IP addresses and subnet masks depending on the type of IP addressing as shown in
. The IP routing table in the CSX400 can be “seeded” with addressing information for networks/stations beyond the remote router.
NETWORK INFORMATION LAYOUT
PC
ETHERNET LAN
IP ADDRESS
SUBNET MASK
GATEWAY
CSX400
SYSTEM NAME
MESSAGE PAP/CHAP
PASSWORD
CSX400 WAN IP
ADDRESS
SUBNET MASK
(IF REQUIRED)
ISDN LINE
SWITCH TYPE
SPIDs, DNs
ISDN
REMOTE ROUTER
WAN IP ADDRESS
SUBNET MASK
(IF REQUIRED)
REMOTE ISDN
PHONE NUMBERS
REMOTE ROUTER
ROUTER NAME
PAP/CHAP PASSWORD
REMOTE LAN NETWORK
IP ADDRESSES
SUBNET MASKS
METRICS
NETWORK AND STATIONS BEYOND
THE REMOTE ROUTER
Figure 5 Network Information Layout
32 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
TCP/IP Route Addresses — If the CSX400 is to direct traffic to networks or stations beyond the remote router, the routing table in the CSX400 can be “seeded” with static IP routes. An IP route includes an IP address, subnet mask and metric. The metric is a number representing the perceived cost in reaching the remote network or station.
The CSX400 routing table must be seeded statically so that it dials out to the appropriate remote router when IP traffic is targeted to networks and stations beyond that remote router. After the link is established, RIP update packets are dynamically added to the routing table. Seeding the routing table is not necessary when the CSX400 never dials out; it discovers remote networks and stations beyond the calling router as soon as RIP updates arrive (provided the remote router supports RIP and RIP packets are allowed to flow on the WAN link).
TCP/IP Default Route — One default route should be designated in the routing table for all traffic that cannot be directed to other specific routes. You need to define the default route for a remote router if the CSX400 will be placing calls to that remote router.
Source (Target) and Remote WAN IP Addresses — You may need to specify a Source WAN IP address and/or a Remote WAN IP address for the WAN connection to the remote router depending on IP address negotiation under PPP. Check with your system administrator for details on whether the router must communicate in numbered or unnumbered mode and what addresses are required.
In unnumbered mode, neither IP address is defined on the link. In numbered mode, one IP address is defined on each end of the WAN link. These addresses may or may not belong to the same subnetwork. They may also be determined automatically, negotiated, or forced by the network administrator.
The CSX400 automatically determines whether to run in unnumbered mode or numbered mode. If unnumbered mode negotiation fails, numbered mode is attempted using the Ethernet LAN IP address as a default. If you have specified a Source WAN IP address, unnumbered mode negotiation is not performed; i.e., the operating mode is numbered. If a Source WAN IP address is explicitly defined, the router will not, as a rule, accept another local address from the remote end.
In numbered mode without an explicit Source WAN IP address, this address can be negotiated to a different value by the remote end.
CSX400 and CSX400-DC User’s Guide 33
Planning for CSX400 ISDN Configuration
If the remote router supports unnumbered mode, neither address needs to be specified. Figure 6
provides a simple example of an unnumbered mode configuration.
WAN LINK
CSX400
REMOTE ROUTER
NO SOURCE
IP ADDRESS
NO REMOTE
IP ADDRESS
Figure 6 CSX400 in Unnumbered Mode
For numbered mode, consider the capabilities of the remote router as well as your requirements.
Specify a Source WAN IP address if the CSX400 must be on the same subnetwork as the remote router.
is an example of a Class B IP network (128.1).
WAN LINK
128.1.129.1
255.255.255.0
CSX400
128.1.1.2
255.255.255.0
REMOTE ROUTER
*SOURCE IP
ADDRESS
Figure 7 CSX400 in Numbered Mode on the Same Subnetwork as the Remote Router
34 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
Specify a Remote WAN IP Address if the remote router does not support IP address negotiation under PPP (i.e., does not have a pre-assigned IP address as shown in
).
WAN LINK
128.1.129.1
255.255.255.0
128.1.1.2
255.255.255.0
CSX400
REMOTE ROUTER
*SOURCE IP
ADDRESS
**REMOTE IP
ADDRESS
*SPECIFY SOURCE IP ADDRESS IF IT MUST BE ON SAME SUBNETWORK AS THE REMOTE ROUTER.
**SPECIFY REMOTE IP ADDRESS IF REMOTE ROUTER DOES NOT HAVE A PRE-ASSIGNED IP ADDRESS.
Figure 8 CSX400 to Remote Router Without a Pre-Assigned IP Address
CSX400 and CSX400-DC User’s Guide 35
Planning for CSX400 ISDN Configuration
NetWare IPX Routing — An Ethernet LAN IPX network number is required for the CSX400 local Ethernet LAN connection. The ISDN WAN link to each remote router must have an assigned
IPX network number. IPX Routes and IPX SAPs for each remote router are also required for the configuration process.
Figure 9 provides an example of the network layout for IPX routing.
NETWORK INFORMATION LAYOUT
ETHERNET LAN
IPX NETWORK NUMBER
PC
CSX400
SYSTEM NAME
PAP/CHAP PASSWORD
WAN LINK
IPX NETWORK NUMBER
ISDN LINE
SPIDs, DNs
PHONE NUMBERS
ISDN
WAN LINK
IPX NETWORK NUMBER
REMOTE ISDN
PHONE NUMBERS
REMOTE ROUTER
ROUTER NAME
PAP/CHAP PASSWORD
IPX ROUTES:
NETWORK NUMBER
HOPS/TICKS
IPX SAPs:
SERVER NAME TYPE
NETWORK NUMBER
NETWORK NODE ADDRESS
SOCKETS
SERVERS AND NETWORK SEGMENTS BEYOND
THE REMOTE ROUTER
Figure 9 Network Information Layout
36 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
IPX Routes — If the CSX400 is to direct traffic to network segments and servers beyond the remote router, the routing table in the CSX400 can be “seeded” with static IPX routes. An IPX route includes a network number, hop count and ticks. The hop count is the number of routers through which traffic must pass to reach the remote network segment or server. Ticks represent how much time the packet takes to reach the destination in roughly 1/18th of a second increments.
The CSX400 routing information table must be seeded statically so that it dials out to the appropriate remote router when IPX traffic is targeted to network segments or servers beyond that remote router. After the link is established, RIP update packets dynamically add to the routing information table in the CSX400. Seeding the routing table is not necessary when a CSX400 never dials out; it will discover routes beyond the calling router as soon as RIP updates arrive (provided the remote router supports RIP).
IPX SAPs — If the CSX400 is to obtain services beyond the remote router, the CSX400 SAP services table must be seeded statically. A SAP service is identified by a server name and corresponding server type, network number, node number and socket. The socket number represents the service (application) within the server node.
The CSX400 SAP services table must be seeded statically so that the device can direct traffic to the appropriate remote router when a service is requested from a server beyond that remote router.
After the link is established, SAP broadcast packets dynamically add to the target router services table. Seeding the table is not necessary when a CSX400 never dials out; it will discover remote services beyond the calling router as soon as SAP broadcasts arrive (provided the remote router supports IPX).
IPX Network Numbers — IPX network numbers are assigned to LAN network segments as well as servers. These numbers should be unique for all IPX networks on the Internetwork.
IPX external network numbers refer to the physical LAN network segments to which servers and routers are connected. The WAN link network number is an external IPX network number. This is a unique number that you choose (or are given by the network administrator) to represent the WAN link between the CSX400 and remote router. The local Ethernet IPX network number is also an external network number.
Servers are identified with internal network numbers. This is a logical network number that identifies the individual server. For a local router to access a server beyond the remote router, you specify a route using the internal network number of a server. To seed the routing table to access a network segment, you specify the external network number of the LAN segment. The network number in the SAP table is the internal network number of the server.
CSX400 and CSX400-DC User’s Guide 37
Planning for CSX400 ISDN Configuration
Node Numbers — Servers can have internal and external node numbers. The internal node number is a logical number assigned by the system administrator to the server. The external node number is the MAC address of the server. When adding SAP services to the SAP table, internal node numbers are used.
Network Information Tables
The following tables list the items you need to define or obtain to configure the router. This information is illustrated in the network information diagrams and described in the previous sections. Worksheets are provided in
Chapter D, so that you can enter details about your CSX400
and remote routers.
provides information for configuring your system settings, Table 5
explains the Remote Router Database configuration settings and
routing configuration.
NOTE
To configure the CSX400, you need to fill out one chart for the CSX400 and one
Remote Router chart for each remote router to be entered into the remote router database. If you are setting up both ends of the network, you need a mirror image of the information listed below for configuring the router on the other end of the ISDN link.
Table 4 Configuring System Settings
Configuration Section Item Description
System Settings
System Settings
Dial Authentication
Password
Router Name
Message
Dial Authentication
Password/Secret
Name used to identify this router; sent to other routers during PAP/CHAP security authentication and displayed in the
Configuration Manager window.
Message saved in the router to be read by a system administrator; displayed on the Configuration Manager main menu window.
This router’s password used for authentication when the router dials out to other routers or is challenged by them.
38 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
Table 4 Configuring System Settings (Continued)
Configuration Section Item Description
System Settings
ISDN Settings
System Settings
Ethernet IP Address
System Settings
Ethernet IPX Network #
ISDN Line Numbers
(supplied by the service provider)
SPIDs and Directory Numbers for one or two ISDN B-Channels
Type of Telco switch
Ethernet IP Address and
Subnet Mask
Ethernet IPX Network
Number
NTT Nippon Telegraph/Telephone
KDD Kokusai Denshin Denwa Co.
NI-1 National ISDN 1
AT&T 5ESS w/Custom Software
Northern Telecom DMS-100
NET3 European ISDN
NET3SW Swiss-Variant ISDN
Address and Subnet Mask for Ethernet port Connection
Network Number for Ethernet port connection
Table 5 Configuring the Remote Router Database
Remote Router
Configuration Database
Item Description
Dial Settings
Dial-In Security
Bridging On/Off
ISDN Line
Disconnect Timer
Maximum Links
ISDN Phone Numbers for one or two
ISDN B-Channels
Disconnect link on inactivity timeout
Maximum number of links for bandwidth on demand (1 or 2)
Minimum links (0, 1, or 2)
Percent Bandwidth utilization threshold
Minimum Links
Threshold
Bandwidth Direction
PAP|CHAP Security
Procedure
Password/Secret
Management on IN|OUT|BOTH
PAP|CHAP|NONE; minimum level of authentication required for the remote router.
The remote router’s password used for authentication when it dials the target router or is challenged by the target router.
Bridging On/Off
Bridging from/to the remote router is On or Off.
Spanning Tree Protocol On or Off
CSX400 and CSX400-DC User’s Guide 39
Planning for CSX400 ISDN Configuration
Table 5 Configuring the Remote Router Database (Continued)
Remote Router
Configuration Database
Item Description
TCP/IP Route Addresses
IPX Routes
IPX SAPs
IP Address, Subnet
Mask, and Metric
Remote WAN IP Address and Subnet Mask a
Source WAN IP Address and Subnet Mask b
IPX Routes: Network
Number, Hop Count and
Ticks
IP Address, Subnet Mask of the remote network beyond the remote router; specifies metric for calculating route efficiency.
IP Address and Subnet Mask of the
Remote Router’s end of the WAN link.
IP Address and Subnet Mask of the local end of the WAN link.
IPX Network Number, Hop Count and
Ticks for stations/nodes beyond the remote router. Hop count is number of routers to pass through and ticks is time delay (each 1/18th of a second).
SAPs: Server Name,
Server Type, Network
Number, Node Number and Socket
Information defining application services available on stations/nodes beyond the remote router.
WAN Network Number
Network Number for the WAN link between target router and remote router a. Used only in PPP numbered mode of addressing b. Used only in PPP numbered mode of addressing
NOTE
Make one chart for each remote router in the remote router database.
40 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
Table 6 Bridging and Routing Controls
Bridging/Routing
Configuration Database
Item Description
Bridging/Routing
Remote Bridging
Destination
TCP/IP Routing
NetWare IPX Routing
Internet Firewall
Destination dialed when bridging any outbound data traffic (required for outbound bridging)
TCP/IP routing to all destinations On or
Off
IPX routing to all destination On or Off
Internet Firewall active or not
CSX400 and CSX400-DC User’s Guide 41
Planning for CSX400 ISDN Configuration
Sample Configuration
A sample configuration of a hypothetical network is provided in this section.
depicts a small office (FP2) accessing a central site (FP3) via an ISDN link. The small office also has access to Internet through an Internet Service Provider (ISP).
The small office and central site have IP routing with a Class B addressing scheme and IPX routing. Bandwidth-on-demand is configured for accessing central site FP3. A maximum of one line is configured for calling the ISP (though two different phone numbers are defined for use).
provides sample system settings, Table 8
provides sample settings for the remote router at
provides sample settings for the remote router at the ISP site and Table 10
provides sample bridging and routing settings.
OFFICE/HOME OFFICE
128.1.129.3
128.1.129.2
128.1.129.1
255.255.255.0
SPID1 40855511111
SPID2 40855511122
DN1
DN2
5551111
5551112
FP2
CSX400
PAC BELL ISDN NETWORK
2 B CHANNELS
64000 BPS
PC/CLIENT WORKSTATION/SERVER
0.0.0.0
255.255.255.255
ISP
SPID1 40855511151
SPID2 40855511162
DN1 5551115
DN2 5551116
INTERNET
SPID1 40855511131
SPID2 40855511142
DN1
DN2
5551113
5551114
128.1.1.3
255.255.255.0
CSX400
FP3
128.1.1.1
255.255.255.0
128.1.1.2
255.255.255.0
WORKSTATION/SERVER
PC/CLIENT
BRIDGING APPLICATION
Figure 10 Sample Network Diagram
WORKSTATION/SERVER
42 CSX400 and CSX400-DC User’s Guide
:
Planning for CSX400 ISDN Configuration
Table 7 CSX400 Sample Configuration Settings
Configuration Section Item Setting
System Settings
System Settings Dial
Authentication Password
Router Name
Message
Dial Authentication
Password/Secret
ISDN SPID#1
FP2
Configured_Mar_1996
FP2passwd
40855511111
System Settings ISDN
Settings
ISDN SPID#2 ISDN
Directory Number #1
40855511122
DN1 5551111
ISDN Directory
Number #2 ISDN
Switch Type
DN2 5551112
System Settings Ethernet
IP Address
Ethernet IP Address and Subnet Mask
DMS-100
128.1.129.1
255.255.255.0
System Settings Ethernet
IPX Network #
Ethernet IPX Address:
Network Number
123
CSX400 and CSX400-DC User’s Guide 43
Planning for CSX400 ISDN Configuration
Configuration Section Item
Table 8 Remote Router: FP3
Setting
ISDN Phone #1 5551113
ISDN Phone #2
Disconnect Timer Value
5551114
60
Remote Router
Database
Dial Settings
Maximum Links
Minimum Links
2
0
Threshold
Bandwidth Direction
75
BOTH
Remote Router
Database
Dial-In Security
Remote Router
Database
Bridging
Minimum Authentication
Remote Router’s
Password/Secret
Bridging On/Off
Spanning Tree Protocol
NONE
ON
OFF
Remote Router
Database
TCP/IP Route
Addresses
Remote Network’s IP
Addresses, Subnet
Masks, and Metrics
Source WAN IP Address and Subnet Mask a
128.1.0.0 255.255.0.0 1
Not required
Remote WAN IP Address and Subnet Mask b
Not required
44 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
Table 8 Remote Router: FP3 (Continued)
Configuration Section Item Setting
Remote Router
Database
IPX Address: Network
Number, Hop Count and
Ticks
1001 1 4
NetWare IPX Routes
Remote Router
Database
SAPs: Server Name,
Server Type, Network
Number, Node Number and Sockets
NetWare IPX SAPs
WAN Network Number a. Used only in PPP numbered mode of addressing b. Used only in PPP numbered mode of addressing
Serv312_fp 4 1001
00-00-00-00-00-01 451 789
NOTE
Use one chart for each remote router in the remote router database.
Configuration Section
Table 9 Remote Router: ISP (Internet Service Provider)
Item Setting
Remote Router Database
Dial Settings
ISDN Phone #1 5551115
ISDN Phone #2 5551116
Disconnect Timer Value
Maximum Links
Default (60 seconds)
Default (1)
Remote Router Database
Dial-In Security
Minimum Links
Threshold
Bandwidth Direction
Minimum Authentication
Remote Router’s Password/Secret
Default (0)
Default (0)
Default (Both)
PAP
ISPpasswd
CSX400 and CSX400-DC User’s Guide 45
Planning for CSX400 ISDN Configuration
Table 9 Remote Router: ISP (Internet Service Provider) (Continued)
Configuration Section Item Setting
Remote RouterDatabase
Bridging
Bridging On/Off Bridging OFF
Remote Router Database
TCP/IP Routes
Spanning Tree Protocol
Remote Network’s IP Addresses,
Subnet Masks, and Metrics
OFF
0.0.0.0 255.255.255.255 1
Source WAN IP Address and Subnet
Mask a
Not required
Remote Router Database
NetWare IPX Routes
Remote WAN IP Address and
Subnet Mask b
IPX Address: Network Number, Hop
Count and Ticks
SAPs: Server Name, Server Type,
Network Number, Node Number and Sockets
Remote Router Database
NetWare IPX SAPs
WAN Network Number a. Used only in PPP numbered mode of addressing b. Used only in PPP numbered mode of addressing
Not required
Not required
Not required
Not required
NOTE
Use one chart for each remote router in the remote router database.
46 CSX400 and CSX400-DC User’s Guide
Planning for CSX400 ISDN Configuration
Table 10 Bridging and Routing Controls
Configuration Section Item Setting
Bridging and Routing Default Remote
Bridging Destination
FP3
TCP/IP Routing On/Off ON
ON NetWare IPX Routing
On/Off
Internet Firewall On/Off ON
Names and Passwords Example
In the sample configuration provided in Table 11 , a small office FP2 communicates with a central
site FP3 and an Internet Service Provider ISP. As indicated in this example, router FP2 has a system password “FP2passwd”. This password is used when FP2 dials out to site FP3 for authentication by that site, and at any time when FP3 challenges FP2. FP3 has a system password
“FP3passwd” which is, likewise, used when FP3 dials out to site FP2 for authentication by FP2, and at any time FP2 challenges FP3. The ISP site has a system password “ISPpasswd” used for the same purpose.
Each router includes the remote router password in the definition of any remote site to which it communicates. The router will use the remote password to authenticate the remote site when the remote router dials in or is challenged by the local site. For example, FP2 has remote router entries for FP3 and ISP, and defined in each entry are the respective remote router password.
The following table shows the names and passwords for each router that must be defined for authentication to be performed correctly. (This assumes that all three systems use some form of authentication protocol.)
CSX400 and CSX400-DC User’s Guide 47
Planning for CSX400 ISDN Configuration
Table 11 Router Names and Passwords
System Name: FP2 Router
System Password FP2passwd
Remote Router Database
Remote Router FP3
Remote’s Password
Remote Router ISP
Remote’s Password
FP3passwd
ISPpasswd
System Name: FP3 Router
System Password FP3passwd
Remote Router Database
Remote Router FP2
Remote’s Password
FP2passwd
System Name: ISP Router
System Password ISPpasswd
Remote Router Database
Remote Router FP2
Remote’s Password
FP2passwd
48 CSX400 and CSX400-DC User’s Guide
5
Ethernet Cabling Requirements
This chapter contains general networking guidelines. Before attempting to install the CSX400 or any additional EPIMs or WPIMs, review the requirements and specifications outlined in this chapter.
NOTE
Your network installation must meet the conditions, guidelines, specifications, and requirements included in this chapter to ensure satisfactory performance of this equipment. Failure to follow these guidelines may result in poor network performance.
Network Requirements
Take care in planning and preparing the cabling and connections for your network. The quality of the connections, the length of cables, and other conditions of the installation play critical roles in determining the reliability of your network.
This chapter contains general guidelines for the following:
• 10BASE-T Twisted Pair Network
• Multimode Fiber Optic Network
• Single Mode Fiber Optic Network
• 10BASE2 Coaxial Cable Network
• Transceiver Requirements
Refer to the following sections that apply to your specific network configuration.
CSX400 and CSX400-DC User’s Guide 49
Ethernet Cabling Requirements
10BASE-T Twisted Pair Network
When connecting a 10BASE-T segment to either of the CSX400 Ethernet interfaces (Twisted Pair
Ethernet Port Interface Module [EPIM-T]), ensure that the network meets the following requirements:
Length — The IEEE 802.3 10BASE-T standard requires that 10BASE-T devices transmit over a
100 meter (328 foot) link using 22–24 AWG unshielded twisted pair wire. However, cable quality largely determines maximum link length. If you use high quality, low attenuation cable, you can achieve link lengths of up to 200 meters. Cable delay limits the maximum link length to 200 meters.
NOTE
Losses introduced by connections at punch-down blocks and other equipment reduce total segment length. For each connector or patch panel in the link, subtract 12 meters from the total length of the cable.
Insertion Loss — Between frequencies of 5.0 and 10.0 MHz, the maximum insertion loss must not exceed 11.5 dB. This includes the attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the link segment.
Impedance — Cabletron Systems 10BASE-T products work on twisted pair cable with
75-to-165 ohms impedance. Unshielded twisted pair cables typically have an impedance of between 85 and 110 ohms. You can also use Shielded Twisted Pair cables, such as IBM Type 1 cable, but this cable has an impedance of 150 ohms.
Jitter — Intersymbol interference and reflections can cause jitter in the bit cell timing, resulting in data errors. 10BASE-T links must not generate more than 5.0 ns of jitter. Make sure the cable meets 10BASE-T link impedance requirements to rule out jitter as a concern.
Delay — The maximum propagation delay of a 10BASE-T link segment must not exceed
1000 ns. This 1000 ns maximum delay limits the maximum link segment length to no greater than
200 meters.
Crosstalk — Signal coupling between different cable pairs within a multi-pair cable bundle causes crosstalk. 10BASE-T transceiver design alleviates concerns about crosstalk, provided the cable meets all other requirements.
50 CSX400 and CSX400-DC User’s Guide
Ethernet Cabling Requirements
Noise — Crosstalk, or externally induced impulses, can cause noise. Impulse noise may cause data errors if the impulses occur at very specific times during data transmission. Generally, noise is not a concern. If you suspect noise-related data errors, you may need to reroute the cable or eliminate the source of the impulse noise.
Temperature — Multi-pair PVC 24 AWG telephone cables typically have an attenuation of approximately 8–10 dB/100 m at 20
°
C (68
°
F). The attenuation of PVC insulated cable varies significantly with temperature. At temperatures greater than 40
°
C (104
°
F), Cabletron Systems strongly recommends using plenum-rated cable to ensure attenuation remains within specification.
Multimode Fiber Optic Network
When connecting a multimode fiber optic link segment to the CSX400 (using an EPIM-F1/F2), ensure that the network meets the following requirements:
Cable Type — Use the following multimode fiber optic media:
• 50/125
µ m fiber optic cabling
• 62.5/125
µ m fiber optic cabling
• 100/140
µ m fiber optic cabling
Attenuation — Test the fiber optic cable with a fiber optic attenuation test set adjusted for an
850 nm wavelength. This test verifies that the signal loss in a cable falls within the following acceptable levels:
• 13.0 dB or less for a 50/125
µ m fiber cable segment
• 16.0 dB or less for a 62.5/125
µ m fiber cable segment
• 19.0 dB or less for a 100/140
µ m fiber cable segment
CSX400 and CSX400-DC User’s Guide 51
Ethernet Cabling Requirements
Budget and Propagation Delay — When you determine the maximum fiber optic cable length to incorporate fiber runs into the network, calculate and consider the fiber optic budget (a total loss of 11.0 dB or less is permissible between stations) and total network propagation delay.
To determine the fiber optic budget, combine the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors. Typical loss for a splice and connector (together) equals
1 dB or less.
Network propagation delay is the amount of time it takes a packet to travel from the sending device to the receiving device. Total propagation delay allowed for the entire network must not exceed 25.6
µ s in one direction (51.2
µ s round trip). If the total propagation delay between any two nodes on the network exceeds 25.6
µ s, you must use bridges or switches.
Length — The maximum possible multimode fiber optic cable length is 2 km (1.24 miles).
However, IEEE 802.3 FOIRL specifies a maximum of 1 km (0.62 miles).
Single Mode Fiber Optic Network
When connecting a single mode fiber optic link segment to the CSX400 (using an EPIM-F3), ensure that the network meets the following requirements:
Cable Type — Fiber optic link segments should consist of 8/125 or 12/125
µ m single mode fiber optic cabling. You can also use 62.5/125
µ m multimode cable with the EPIM-F3; however, multimode cable allows for greater optical loss, and limits the possible distance to 2 km.
Attenuation — Test the fiber optic cable with a fiber optic attenuation test set adjusted for a
1300 nm wavelength. This test verifies that the signal loss in a cable falls within the acceptable level of 10.0 dB or less for any given single mode fiber optic link.
Budget and Propagation Delay — When you determine a maximum fiber optic cable length, you must calculate and consider the fiber optic budget (a total loss of 10.0 dB or less between stations) and total network propagation delay.
To determine the fiber optic budget, combine the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors. Typical loss for a splice and connector (together) equals 1 dB or less.
Network propagation delay is the amount of time it takes a packet to travel from the sending device to the receiving device. Total propagation delay for the entire network must not exceed 25.6
µ s in one direction (51.2
µ s round trip). If the total propagation delay exceeds 25.6
µ s, you must use bridges or switches to re-time the signal.
52 CSX400 and CSX400-DC User’s Guide
Ethernet Cabling Requirements
Length — If your network meets all system budgets, the maximum single mode fiber optic cable length can reach 5 km (3.1 miles) with bridges or switches at each segment end. The FOIRL specifies a maximum of 1 km (0.62 miles).
10BASE2 Coaxial Cable Network
When connecting a thin coaxial cable segment to the CSX400 (using an EPIM-C), ensure that your network meets the following requirements:
Cable Type — Use only 50-ohm RG 58A/U type coaxial cable for thin coaxial cable segments.
Length — The thin coaxial cable segment must not exceed 185 meters.
Terminators — Terminate each end of a thin coaxial cable segment.
Connectors — You can use up to 29 T-connectors throughout the length of the cable segment for host connections. Ensure that all connections are spaced 0.5 meters or more from one another or from terminators.
If you use an excessive number of barrel connectors within the cable segment (e.g., finished wall plates with BNC feed-throughs), you may need to reduce the number of host connections. For special network design information, contact Cabletron Systems Technical Support.
Grounding — For safety, ground only one end of a thin coaxial cable segment. Do NOT connect
EPIM BNC ports to earth ground.
!
CAUTION
Connecting a thin coaxial cable segment to earth ground at more than one point could produce dangerous ground currents.
Transceiver Requirements
When you connect an external network segment to an EPIM-A in your CSX400 through a transceiver, that transceiver must meet IEEE 802.3 standards or Ethernet version 1.0 or 2.0 requirements. The transceiver must also have SQE disabled.
CSX400 and CSX400-DC User’s Guide 53
Ethernet Cabling Requirements
54 CSX400 and CSX400-DC User’s Guide
6
Installation
This chapter outlines the procedure for attaching the CSX400 to the network. Ensure that the
network meets the guidelines and requirements outlined in Chapter 5 , Ethernet Cabling
Requirements , before installing the CSX400. To install the HSIM and WPIMs, you need the
following items:
• Antistatic wrist strap (provided with the CSX400)
• Phillips screwdriver
Unpacking the CSX400
Unpack the CSX400 as follows:
1.
Remove the shipping material from the box and carefully remove the CSX400.
2.
Visually inspect the CSX400. If there are any signs of damage, contact Cabletron Systems
(refer to the
Getting Help section) immediately.
3.
Read the CSX400 Release Notes included in the shipping box.
Guidelines for Installations
Only qualified personnel should perform installation procedures.
!
CAUTION
Do not connect EPIM ports to the Public Switched Telephone Network (PSTN).
Hazardous voltages exist that may damage the CSX400.
Installation sites must be within reach of the network cabling and meet the requirements listed below:
• A properly grounded power receptacle must be within seven feet of the location.
CSX400 and CSX400-DC User’s Guide 55
Installation
• In a shelf installation, the shelf must be able to support 13.6 kg (30 lb) of static weight for each device on the shelf.
• Maintain a temperature of between 5
°
C (41
°
F) and 40
°
C (104
°
F) at the installation site with fluctuations of less than 10
°
C (50
°
F) per hour.
• Maintain a two-inch clearance for each side and the back of the device for adequate ventilation.
Installing Interface Modules
Depending on your specific application, install Cableton Systems WAN Port Interface Modules
(WPIMs) and the CSX-COMP/ENCR modules into the CSX400 before proceeding with the
installation of your CSX400. Refer to the Installing Ethernet Port Interface Modules (EPIMs) ,
Installing WAN Port Interface Modules (WPIMs) , and
sections within this chapter for installation instructions.
!
CAUTION
The EPIMs and WPIMs, and CSXCOMP/ENCR for the CSX400 are sensitive to static discharges. Use a grounding strap and observe all static precautions during installation. Failure to do so could result in damage to the EPIMs, WPIMs, CSXCOMP/
ENCR, and the CSX400.
NOTE
The CSX400 must have at least one EPIM and one WPIM installed before you can begin configuring the device.
Installing Ethernet Port Interface Modules (EPIMs)
This section contains procedures for adding or replacing an Ethernet Port Interface Module
(EPIM) to upgrade or change the capabilities of your CSX400. After installing your new EPIM, refer to
,
Ethernet Cabling Requirements , for network configuration guidelines.
Appendix A , EPIM Specifications , provides specification information on Cabletron Systems
EPIMs.
!
CAUTION
Before performing installation procedures, ensure that the requirements outlined in the section,
Guidelines for Installations , are met.
56 CSX400 and CSX400-DC User’s Guide
Installation
To install an EPIM, perform the following steps:
!
CAUTION
When removing an existing EPIM, make sure to pull the module straight out to avoid damaging the connector.
1.
Attach the disposable grounding strap to your wrist (refer to the instructions outlined on the disposable grounding strap package).
2.
Remove the coverplate or the existing EPIM (whichever applies).
3.
Slide your new EPIM into place, making sure the connectors on the rear of the module and inside the CSX400 attach properly as shown in
.
4.
Install the mounting screw.
ETHERNET 1
ETHERNET 2
EPIM
Mounting
Screw
Figure 11 Installing an EPIM
CSX400 and CSX400-DC User’s Guide 57
Installation
Removing the CSX400 Cover
This section describes how to remove the CSX400 chassis cover. The cover must be removed to install a WAN Port Interface Module.
!
CAUTION
DO NOT REMOVE THE COVER FROM THE CSX400 WHILE POWER IS APPLIED
TO THE UNIT.
DO NOT POWER UP THE DEVICE AGAIN UNTIL THE COVER AND SCREWS ARE
IN PLACE.
DECKEL VON DAS CSX400 NICHT ABZIEHEN UNTER SPANNUNG.
CSX400 NICHEINSCHALTEN SO LANG DER DECKEL UND SCHRAUBEN NICHT
EINGEBAUT SIND.
NO DEBE DE REMOVER LA TAPA DURENTE QUE ESTE CONELTADO A LA
CORRIENTE.
NO ENCHUFE A LA CORRIENTE HASTA QUE LA TAPA Y LOS TORNILLOS ESTEN
EN SU LUGAR.
To remove the chassis cover, proceed as follows:
1.
Disconnect the CSX400 from the network as follows:
TIP a.
Unplug the power cord from the rear of the CSX400 chassis.
Before performing step b , mark any cables connected to the CSX400 according to their
associated port numbers. This is recommended for ease of reinstallation.
b.
Disconnect all network cables attached to the CSX400.
2.
Use a Phillips screwdriver to remove the seven screws that attach the chassis cover to the unit.
Place the screws aside. (See
3.
While facing the back of the unit, remove the chassis cover by pulling the cover toward you and then up.
58 CSX400 and CSX400-DC User’s Guide
Installation
Removing the CSX400-DC Cover
This section describes how to remove the CSX400-DC chassis cover. The cover must be removed to install a WAN Port Interface Module (WPIM).
!
CAUTION
Do not remove the cover from the CSX400-DC while power is applied to the unit. Do not power up the device again until the cover and screws are in place.
To remove the chassis cover, proceed as follows:
1.
Disconnect the CSX400-DC from the network as follows: a.
Flip the DC switch located in the back of the CSX400-DC to the “off” position.
TIP
Before performing step b, mark any cables connected to the CSX400-DC according to their associated port numbers. This is recommended for ease of reinstallation.
b.
Disconnect all network cables attached to the CSX400-DC.
2.
Use a Phillips screwdriver to remove the seven screws that attach the chassis cover to the unit.
Place the screws aside. (See
3.
While facing the back of the unit, remove the chassis cover by pulling the cover toward you and then up.
48/60Vdc ---
2.2A/1.5A
48/60Vdc ---
2.2A/1.5A
Removing the Cover Screws
Lifting the Cover Off
Figure 12 Removing the Chassis Cover
CSX400 and CSX400-DC User’s Guide 59
Installation
Installing WAN Port Interface Modules (WPIMs)
!
CAUTION
Before performing installation procedures, ensure that the requirements outlined in the section,
Guidelines for Installations , are met.
To install a WPIM into the CSX400, refer to
Figure 13 and complete the following steps:
!
CAUTION
When removing an existing WPIM, make sure to pull the module straight out to avoid damaging the connector.
1.
Attach the disposable grounding strap to your wrist (refer to the instructions outlined on the disposable grounding strap package).
2.
Remove the CSX400 cover (refer to
Removing the CSX400-DC Cover for instructions).
3.
Remove the blank faceplate from the appropriate WAN slot.
4.
Orient the WPIM as shown in Figure 13 .
5.
Carefully insert the WPIM connector into the WPIM connector pins on the CSX400.
6.
Press down firmly on the WPIM until the pins slide all the way into the connector. Ensure that the WPIM seats flush on the standoffs.
7.
Secure the WPIM to the three standoffs using the provided screws.
8.
Replace the CSX400 cover.
60 CSX400 and CSX400-DC User’s Guide
WPIM
WPIM Screws
Installation
WPIM
Connector
Figure 13 Installing WPIMs
WPIM
Connector Pins
Standoffs
CSX400 and CSX400-DC User’s Guide 61
Installation
CSX-COMP/ENCR Installation
This section contains instructions on how to install the CSX-COMP/ENCR into the CSX400 motherboard. To help eliminate any potential problems during or after installation, read and understand all of the following steps:
1.
Attach one end of the antistatic wrist strap to your wrist and the other end to an approved electrical ground.
2.
Unpack the CSX-COMP/ENCR by carefully removing it from the shipping box and then from the protective plastic bag. Do not cut the bag as the device could be damaged. If there are any signs of damage, contact the Cabletron Systems Global Call Center (refer to the
section).
3.
Power down the CSX400 before you install the CSX-COMP/ENCR.
4.
Remove the chassis cover of the CSX400 or CSX400-DC to install the CSX-COMP/ENCR
(refer to
Removing the CSX400 Cover , on page 58 or
Removing the CSX400-DC Cover , on page 59 ).
NOTE
The motherboard of the CSX400 has two D-Type connectors. Use the left-most connector (as you are facing the front of the chassis). Ensure the CSX-COMP/ENCR is aligned such that its connector pins correctly align with the D-Type connector on the chassis or module.
5.
Locate the D-Type connector and the standoffs on the CSX400 (refer to
6.
The D-Type connector pins of the CSX-COMP/ENCR only fit one way onto the CSX400
D-Type connector. Lower the CSX-COMP/ENCR onto the standoffs and align the connector with the connector pins. Carefully insert the connector pins of the CSX-COMP/ENCR into the
CSX400 connector.
7.
Press down firmly on the CSX-COMP/ENCR until the pins fit all the way into the connector.
8.
Secure the CSX-COMP/ENCR with the standoff screws supplied with the CSX-COMP/ENCR.
The CSX-COMP/ENCR installation is complete.
62 CSX400 and CSX400-DC User’s Guide
Installation
Standoff Screws
D-Type
Connector Pins
D-Type
Connector
CSX-COMP/ENCR
Standoff
2204N01
Detail
Figure 14 CSX-COMP/ENCR
Installing the CSX400
The CSX400 may be installed on a tabletop, shelf or in a 19-inch rack.
Refer to Tabletop and Shelf Installations for information concerning a tabletop or shelf
installation. CSX400 and CSX400-DC Rackmount Installation
describes the rackmount installation.
Tabletop and Shelf Installations
The following two subsections provide guidelines for installation on a tabletop or shelf.
!
CAUTION
Before performing installation procedures, ensure that the requirements outlined in the section,
, are met.
To install the CSX400 on a tabletop or shelf, locate the CSX400 within seven feet of its power source with an unrestricted free surface area as shown in
Figure 15 , and complete the following
steps:
1.
Locate the six round rubber feet included with your CSX400.
CSX400 and CSX400-DC User’s Guide 63
Installation
2.
Peel the paper backing off the round rubber feet, and adhere them to the bottom of the CSX400.
Place one rubber foot near each of the four corners of the CSX400, and evenly space the remaining two near the center.
21 IN.
16 IN.
18 IN.
Figure 15 Tabletop or Shelf Installation
Continue the installation by connecting power as described in Connecting the CSX400-DC to the
CSX400 and CSX400-DC Rackmount Installation
There are two methods of attaching the rackmount brackets, included with the CSX400 and
CSX400-DC, that are discussed in this section.
Attaching the Rackmount Brackets to the
CSX400 discusses a typical installation of the CSX400, and
Bonding the Rackmount Brackets to the CSX400-DC
discusses the GR-1089-CORE Section 9 bonding requirements for the
CSX400-DC when installing rackmount brackets. Refer to the procedure that applies to your installation.
WARNING
Before installing the CSX400 or CSX400-DC into a rack, ensure that the rack supports the device(s) without compromising the stability of the rack. Otherwise, personal injury and/or equipment damage may result.
Rackmounting the CSX400 requires the following steps:
• Attaching the rackmount brackets
• Installing the CSX400 in a 19-inch rack
• Connecting the CSX400 to a power source
Tools Required
• Phillips screwdriver
64 CSX400 and CSX400-DC User’s Guide
Installation
Materials Required
The following parts are included with the CSX400:
•
Left (P/N 8501242-01) and right (P/N 8501241-01) rackmount brackets ( Figure 16 ).
• 6-32 x 1/4 inch flat-head screws (4)
!
CAUTION
Do not use screws other than those supplied with the CSX400 to perform the following procedures.
Rackmount Brackets (2)
Figure 16 CSX400 and CSX400-DC Rackmount Hardware
Attaching the Rackmount Brackets to the CSX400
Refer to Figure 17 and proceed as follows to attach the rackmount brackets:
1.
Remove and save the four 6-32 x 1/4 inch flat-head screws that are located along the front edges of each side of the CSX400.
2.
Locate the two rackmount brackets from the package included with your CSX400.
CSX400 and CSX400-DC User’s Guide 65
Installation
3.
Using the four 6-32 x 1/4 inch flat-head screws, attach the rackmount brackets to the sides of the CSX400 as shown in
.
Rackmount
Brackets (2)
Screws (4)
Figure 17 Installing the Rackmount Brackets
2012_09
4.
Position the CSX400 between the vertical frame members of the 19-inch rack.
5.
Fasten the CSX400 with mounting screws as shown in
Bonding the Rackmount Brackets to the CSX400-DC
If the CSX400-DC is going to be mounted in a rack and needs to meet the GR-1089-CORE
Section 9 bonding requirements, use the following instructions to install it into a 19-inch rack.
1.
Remove and discard the four cover screws (two from each side) located along the front edges of each side of the CSX400-DC.
2.
Remove the paint from around the area near the mounting holes on the left and right side of the
cover of the CSX400-DC. See Figure 18 .
3.
Apply a thin layer of anti-oxidant to the surface where the paint was removed.
66 CSX400 and CSX400-DC User’s Guide
Installation
4.
Locate the four 6-32 x 3/8-inch flathead cover replacement screws in the rackmount kit. Use these screws to attach the rackmount brackets to the CSX400-DC as shown in
.
Rackmount Brackets (2)
Remove Paint
Figure 18 Installing the Rackmount Brackets
5.
Position the CSX400 between the vertical frame members of the 19-inch rack.
6.
Fasten the CSX400-DC with thread-forming screws as shown in Figure 19 .
19-Inch Rack
Screws (4)
2012_10
Figure 19 Installing the CSX400 and CSX400-DC in a Rack
CSX400 and CSX400-DC User’s Guide 67
Installation
Connecting the CSX400 to the Power Source
NOTE
The CSX400 has a universal power supply. This allows you to connect the CSX400 to power sources of 100–125 and 200–240 Vac, 50/60 Hz.
To connect the CSX400 to the power source, perform the following steps:
1.
Plug the power cord into the back panel of the CSX400.
2.
Plug the other end of the power cord into a grounded wall outlet.
3.
Verify that the PWR LED is on, indicating that the CSX400 is receiving power. After the
CSX400 runs a self test, the CPU LED blinks green indicating normal operation. If the LED remains red, the processor is faulty; contact Cabletron Systems Technical Support (refer to
.)
4.
Proceed to Chapter 7 to configure the CSX400.
68 CSX400 and CSX400-DC User’s Guide
Installation
Connecting the CSX400-DC to the Power Source
Th CSX400-DC requires either a 48 Vdc or 60 Vdc (48/60 Vdc), 3.5 A (maximum), external power source supplied by three 18 AWG (American Wire Gauge) copper wires. These wires must be terminated to the dc input power strip shown in
with either ring or spade terminals. The dc power supply in the CSX400-DC has its own on/off switch and is rated at 100 watts. To connect the CSX400-DC to a 48/60 Vdc power source, face the back panel, then refer to
and proceed as follows:
ONLY QUALIFIED PERSONEL SHOULD PERFORM THESE INSTALLATION
PROCEDURES.
TO REDUCE THE RISK OF ELECTRIC SHOCK OR ENERGY HAZARDS:
• CONNECT TO A RELIABLY GROUNDED 48/60 VDC SELV SOURCE.
• ENSURE THE BRANCH CIRCUIT OVERCURRENT PROTECTION IS
RATED AT A MIMINUM OF 10 A.
• USE 18 AWG SOLID COPPER CONDUCTORS ONLY.
• ENSURE THAT A READILY ACCESSIBLE DISCONNECT DEVICE THAT IS
SUITABLY APPROVED AND RATED, IS INCORPORATED IN THE FIELD
WIRING.
TO BE INSTALLED IN A RESTRICTED ACCESS AREA IN ACCORDANCE WITH
THE NEC OR THE AUTHORITY HAVING JURISDICTION.
CSX400 and CSX400-DC User’s Guide 69
Installation
DC Input Power Strip
ON/OFF
+
48 or 60 Vdc
Power Source
–
Earth
Ground
Figure 20 48/60 Vdc Power Supply Connections
To prevent injury or damage to the equipment, remove power from the 48/60 Vdc power source before proceeding with the following steps:
1.
Connect the ground terminal of the dc input power strip to an appropriate earth ground
(green wire from power supply).
2.
Refer to Figure 20 for the proper connections to a 48/60 Vdc power source. Then connect the
output leads of the 48/60 Vdc power source being used to the labeled negative (-) and positive
(+) terminals on the dc input power strip.
3.
Restore power to the 48/60 Vdc power sources.
4.
Press the on/off power switch on.
NOTE
The CSX400 sounds an audible alarm if there is a polarity reversal. If the alarm sounds, turn off the 48/60 Vdc power source to that power supply. Then reverse the positive and negative leads to the dc input power strip of that power supply. Restore power from the 48/60 Vdc power source. Press the on/off switch to on. If the alarm sounds again, press the power switch to off and call Cabletron Systems. Refer to
70 CSX400 and CSX400-DC User’s Guide
7
CSX400 Configuration with QuickSET
\
This chapter provides step-by-step instructions for configuring the CSX400 using QuickSET.
NOTE
Before configuring the device, you must set up your computer based on the READ ME
FIRST! documentation included with the product and installed the CSX400 using the
QuickSTART Guide located in the QuickSET CD case.
Normally, QuickSET automatically establishes a communication link with the CSX400 being configured. However, under certain circumstances, QuickSET may not be able to locate the
CSX400 automatically. In this case, the IP Address window shown in
displays:
Figure 21 IP Address Window
CSX400 and CSX400-DC User’s Guide 71
CSX400 Configuration with QuickSET
Enter the IP address of the CSX400 in the appropriate field and the password if applicable (the default password is public). Click on the OK button and QuickSET locates the CSX400 on the
network and displays the First Introductory window shown in Figure 22
.
NOTE
The QuickSET version number shown on each window in this chapter may not reflect the QuickSET version number running on your system.
Figure 22 First Introductory Window
Click on the Next>> button to continue the CSX400 configuration, and the Second Introductory
window shown in Figure 23 displays.
72 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Figure 23 The Second Introductory Window
Click on the Next>> button and go to the Ethernet 1 and 2 configuration window to continue the
CSX400 configuration.
CSX400 and CSX400-DC User’s Guide 73
CSX400 Configuration with QuickSET
Ethernet Configuration
This section explains how to configure the CSX400 Ethernet 1 and 2 fields using QuickSET.
Ethernet 1 and 2 Configuration Window
The Ethernet 1 and 2 configuration window, shown in
Figure 24 , displays after clicking on the
Next>> button in the Second Introductory window. The Local Ethernet IP address and Subnet
Mask fields shown on the Ethernet 1 and 2 configuration window are used for setting an IP address and Subnet Mask.
Figure 24 Ethernet 1 and 2 Configuration Window
74 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
This section describes each of the fields on the Ethernet 1 and 2 configuration window.
Local Ethernet 1 IP Address — Displays the IP address for Ethernet interface 1. Place the cursor in this field and type the preferred IP address in Dotted Decimal Notation (DDN) format.
The IP address must be entered in this field to continue.
Local Ethernet 1 Subnet Mask — The Subnet Mask takes the same form as an IP address; four groups of three decimal digits, separated by periods. Each group must be in the numerical range of
0 to 255. The first time you use QuickSET, the Subnet Mask field displays a default Subnet Mask, based on the IP address entered, when it is clicked on. If you wish to use a different Subnet Mask, enter it at this time in DDN format. A Subnet Mask must be entered in this field to continue.
Local Ethernet 2 IP Address — Displays the IP address for Ethernet interface 2. Place the cursor in this field and type in the preferred IP address in DDN format.
Local Ethernet 2 Subnet Mask — Displays the Subnet Mask for Ethernet interface 2. Place the cursor in this field and type in the Subnet Mask in DDN format. The first time you use QuickSET, the Subnet Mask field displays a default Subnet Mask, based on the IP address entered, when it is clicked on. If you wish to use a different Subnet Mask, enter it at this time, and type the Subnet
Mask in DDN format. A Subnet Mask must be entered in this field to continue if an IP address is entered for the Local Ethernet 2 interface.
CSX400 and CSX400-DC User’s Guide 75
CSX400 Configuration with QuickSET
Secondary IPs — The Secondary IPs window shown in
Figure 25 displays after clicking on the
Secondary IPs... button, and shows the list of current Secondary IP addresses. The CSX400 can support multiple IP Subnets, therefore, there can be multiple Secondary IP Addresses assigned to an Ethernet interface. To add a Secondary IP address, click on the Add IP button and enter the IP
Address, and Subnet Mask in their corresponding fields.
When you have finished making changes, click on the Apply Changes button. Click on the Done button when you are finished.
Figure 25 Secondary IPs Window
76 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
System Passwords — The System Passwords window shown in
clicking on the Passwords button in the Ethernet 1 and 2 configuration window. The system passwords used by QuickSET are the same as the Community Names of the device that are used in
Local Management through a TELNET application. System passwords allow you to control management access by establishing three passwords. Each password controls varying levels of access to the CSX400 management.
Once passwords are assigned, you must use the SuperUser System password at the User Password prompt when initiating a QuickSET session. If you are configuring the CSX400 for the first time or if no passwords are assigned, the default System password for each access level is preset to public.
Figure 26 System Passwords Window
CSX400 and CSX400-DC User’s Guide 77
CSX400 Configuration with QuickSET
The following definitions explain the fields in the System Passwords window shown in Figure 26 .
Read Only Access — This access level allows reading of device parameters not including system passwords. Place the cursor in this field and type the new system password. Retype the system password in the Confirm Password field below the Read Only Access field.
Read/Write Access — This access level allows editing of some device configuration parameters not including changing system passwords. Place the cursor in this field and type the new system password. Retype the system password in the Confirm Password field below the Read/Write
Access field.
QuickSET (SuperUser) — This access level allows full management privileges. Place the cursor in this field and type the new system password. Retype the system password in the Confirm
Password field below the QuickSET (SuperUser) field.
!
CAUTION
If you edit the SuperUser system password, be certain not to forget it. If you do, you cannot perform management functions without returning the device to its factory default configuration. This effectively erases any configuration work you may have done.
When finished configuring the CSX400 system passwords, click on the OK button in the System
Passwords window to return to the Ethernet 1 and 2 configuration window.
Once your Ethernet configuration is complete, click on the Next>> button and go to the Wide
Area 1 and 2 Configuration section.
78 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Wide Area 1 and 2 Configuration
NOTE
When configuring WAN interfaces 1 and 2 with QuickSET, the Wide Area configuration window that displays corresponds to the specific WPIM that is installed into the
CSX400.
NOTE
Configuration for the Wide Area 2 interface is the same as the configuration for the
Wide Area 1 interface.
Both Wide Area 1 and Wide Area 2 slots must be populated to initiate Wide Area interface 2 configuration.
Refer to the appropriate section listed below to configure your Wide Area 1 or 2 interface on the
CSX400:
Wide Area T1 Configuration Window
Wide Area E1 Configuration Window
Wide Area DI Configuration Window
Wide Area Synchronous Configuration Window
Wide Area DDS Configuration Window
Wide Area HDSL Configuration Window
CSX400 and CSX400-DC User’s Guide 79
CSX400 Configuration with QuickSET
Wide Area T1 Configuration Window
The Wide Area T1 configuration window shown in
displays after clicking on the
Next>> button in either the Ethernet 1 and 2 configuration window or the Wide Area Frame Relay
Time Slot and PPP configuration windows, depending on whether you have installed one or two
WPIMs in the CSX400, and in what order you are configuring them.
Figure 27 Wide Area T1 Configuration Window
80 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
This section explains how to configure the CSX400 Wide Area T1 interface using QuickSET.
NOTE
The service provider (i.e., AT&T, Sprint, MCI, etc.) determines the settings for many of the following fields. Consult the service provider for the correct settings.
The line configuration information shown in
Table 12 must be supplied by your service provider.
The CSX400 factory default settings are in bold.
Table 12 Telco Configuration Information
Configuration Information
Required by User
Configuration Information
Supplied by Service Provider
T1 Frame Type
T1 Line BuildOut
T1 Line Coding
T1 Loop-Back
T1 Transmit Clock Source
Time Slots (for Fractional T1)
ESF or D4
0 dB, -7.5 dB, -15 dB
B8ZS or AMI
No Loop or Line Loop
Loop-Timing or Local-Timing
Time Slot (1-24) Assignments
The following definitions explain the fields in the T1 WAN configuration window.
T1 Frame Type — Displays the T1 frame type. The selections are ESF (Extended Superframe) and D4 (AT&T D4). The default setting for this field is ESF.
T1 Line BuildOut — Displays the signal level for the physical T1 line. Set this to 0 dB unless the service provider recommends another setting. The default setting for this field is 0 dB. The following options are available for this setting:
• 0 dB
• -7.5 dB
• -15 dB
T1 Line Coding — Displays the line coding for the physical T1 line. The selections for this field are B8ZS and AMI. The default setting for this field is B8ZS.
CSX400 and CSX400-DC User’s Guide 81
CSX400 Configuration with QuickSET
T1 Loop-Back — Network Loopback is a testing procedure that segments the line and allows you to isolate faults. The selections for this field are No Loop and Line Loop. In Line Loop all 24 channels are looped back to the T1 line. The CyberSWITCH must be in Loop-Timing mode to use this option. The default setting is No Loop.
T1 Transmit Clock Source — Displays the T1 Transmit Clock Source. The choices for this field are Loop-Timing (Extracted Line Data) and Local-Timing (Internal Clock). The default setting for this field is Loop-Timing.
Protocol — Displays the active protocol for the Wide Area T1 interface. The selections for this field are either Frame Relay or Point-to-Point (PPP). The default setting for this field is PPP.
Link Management Protocol — If Frame Relay is the selected protocol, this field displays Q.933
Annex A and T1.617 Annex D. The default for Frame Relay is T1.617 Annex D. This field is grayed out and not used for PPP.
Once the Wide Area T1 configuration is complete, click on Next>>, and go to the Wide Area
Frame Relay Time Slot Configuration Window or
Wide Area PPP Time Slot Configuration
Window section, depending on which protocol you are using.
82 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Wide Area E1 Configuration Window
The Wide Area (E1) configuration window shown in
displays after clicking on the
Next>> button in either the Ethernet 1 and 2 configuration window or the Wide Area Frame Relay
Time Slot and PPP configuration windows, depending on whether you have installed one or two
WPIMs in the CSX400, and what order you are configuring them.
This section explains how to configure the CSX400 E1 WAN interface using QuickSET.
NOTE
Figure 28 Wide Area E1 Configuration Window
The service provider determines the settings for the following fields. Consult the service provider for the correct settings.
CSX400 and CSX400-DC User’s Guide 83
CSX400 Configuration with QuickSET
The line configuration information shown in
Table 13 must be supplied by your service provider.
The CyberSWITCH factory default settings are in bold type.
Table 13 Telco Configuration Information
Configuration Information
Required by User
Configuration Information
Supplied by Service Provider
E1 Frame Type
E1 Line Coding
E1 Loop-Back
E1 Transmit Clock Source
Time Slots (for Fractional E1)
E1 or E1-CRC
HDB3 or AMI
No Loop or Line Loop
Loop-Timing or Local-Timing
Time Slot (1-32) Assignments
The following definitions explain the fields in the Wide Area E1 configuration window.
E1 Frame Type — Displays the E1 frame type. The selection toggles between E1 and E1-CRC.
The default setting for this field is E1.
E1 Line Coding — Displays the line coding for the physical E1 line. The selections toggle between HDB3 and AMI. The default setting for this field is HDB3.
E1 Loop-Back — Network Loopback is a testing procedure that segments the line and allows you to isolate faults. Click on the radio button to select either the No Loop or Line Loop option. In
Line Loop, all 32 channels are looped back to the E1 line. The CyberSWITCH must be in
Loop-Timing mode to use this option. The default setting is No Loop.
E1 Transmit Clock Source — Displays the E1 Transmit Clock Source. Click on the radio button to select either the Loop-Timing (Extracted Line Data) or Local-Timing (Internal Clock) option.
The default setting for this field is Loop-Timing.
Protocol — Displays the active protocol for the E1 WAN port. The selections for this field are either Frame Relay or PPP. The default setting for this field is PPP.
Link Management Protocol — If Frame Relay is the selected protocol, this field displays Q.933
Annex A and T1.617 Annex D. The default for Frame Relay is T1.617 Annex D. This field is grayed out and not used for PPP.
84 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Once the E1 WAN configuration is complete, click on the Next>> button and go to the
Frame Relay Time Slot Configuration Window or
Wide Area PPP Time Slot Configuration
Window section, depending on which protocol you are using.
Wide Area DI Configuration Window
The Wide Area (DI) configuration window shown in
displays after clicking on the
Next>> button in the Ethernet 1 and 2 configuration window or the Wide Area Frame Relay Time
Slot and PPP configuration windows, depending on whether you have installed one or two WPIMs in the CSX400, and in what order you are configuring them.
This section explains how to configure the CSX400 Wide Area DI interface using QuickSET.
NOTE
Figure 29 Wide Area DI Configuration Window
The service provider (i.e., AT&T, Sprint, MCI, etc.) determines the settings for the following fields. Consult the service provider for the correct settings.
CSX400 and CSX400-DC User’s Guide 85
CSX400 Configuration with QuickSET
The line configuration information shown in
Table 14 must be supplied by your service provider.
The CyberSWITCH factory default settings are in bold.
Table 14 Telco Configuration Information
Configuration Information
Required by User
Configuration Information
Supplied by Service Provider
T1 Frame Type
T1 Line BuildOut
T1 Line Coding
T1 Loop-Back
T1 Transmit Clock Source
Time Slots (for Fractional T1)
ESF or D4
0dB, -7.5 dB, -15 dB
B8ZS or AMI
No Loop or Line Loop
Loop-Timing or Local-Timing
Time Slot (1-24) Assignments
The WPIM-DI has two connectors allowing two devices to share the available Time Slots in a T1
WAN link. The Network Interface (NI) is the main connection to the WAN link while the
Drop-and-Insert (DI) interface is used by other T1 equipment to share the main T1 link.
The following definitions explain the fields in the DI WAN configuration window.
DI Functionality — Displays the status of the Drop-and-Insert function. Click on the Enable radio button to enable the Drop-and-Insert function, that allows any Time Slots set to 0 in the Wide
Area Frame Relay Time Slot and PPP configuration windows to be used by the Drop-and-Insert port interface.
T1 Frame Type — Displays the DI frame type. Click on the radio button to select either the ESF or D4 option. The default setting for this field is ESF.
86 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
T1 Line BuildOut — Displays the signal level for the physical DI line. Set this to 0 dB unless the service provider recommends another setting. The default setting for this field is 0 dB. Click on the appropriate radio button for the following levels:
• 0 (Zero) dB
• -7.5 dB
• -15 dB
T1 Line Coding — Displays the line coding for the physical DI line. The selections toggle between B8ZS and AMI. The default setting for this field is B8ZS.
T1 Loop-Back — Network Loopback is a testing procedure that segments the line and allows you to isolate faults. The selections for this field toggle between No Loop and Line Loop. In Line Loop all 24 channels are looped back to the DI line. The CyberSWITCH must be in Loop-Timing mode to use this option. The default setting is No Loop.
T1 Transmit Clock Source — Displays the DI Transmit Clock Source. Click on the radio button to select either the Loop-Timing (Extracted Line Data) or Local-Timing (Internal Clock) option.
The default setting for this field is Loop-Timing.
Protocol — Displays the active protocol for the Wide Area DI interface. The selections for this field are Frame Relay and PPP. The default setting for this field is PPP.
Link Management Protocol — If Frame Relay is the selected protocol, this field displays Q.933
Annex A and T1.617 Annex D. The default for Frame Relay is T1.617 Annex D. This field is grayed out and not used for PPP.
Once the Wide Area DI configuration is complete, click on the Next>> button, and go to the Wide
Area Frame Relay Time Slot Configuration Window or the
Configuration Window section, depending on which protocol you are using.
CSX400 and CSX400-DC User’s Guide 87
CSX400 Configuration with QuickSET
Wide Area Synchronous Configuration Window
The Wide Area Synchronous configuration window shown in
Figure 30 displays after clicking on
the Next>> button in either the Ethernet 1 and 2 configuration window or the Wide Area Frame
Relay Time Slot and PPP configuration windows, depending on whether you have installed one or two WPIMs in the CSX400, and in what order you are configuring them.
This section explains how to configure the CSX400 Synchronous WAN port using QuickSET.
NOTE
Figure 30 Wide Area Synchronous Configuration Window
The service provider (i.e., AT&T, Sprint, MCI, etc.) determines the settings for the following fields. Consult the service provider for the correct settings.
88 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
The line configuration information shown in
is determined by your service provider. The
CSX400 factory default settings are in bold.
Table 15 Telco Configuration Information
Configuration
Information Required by
User
Configuration Information
Supplied by Service Provider
Sync Port Type
Sync Flow Control
Sync Clock Speed
V.35, RS422, RS232 or X.21
Force CTS on or off
Force DSR on or off
64000
The following definitions explain the fields in the Synchronous WAN configuration window.
Sync Port Type — Displays the Synchronous port electrical interface type. The selections for this field are V.35, RS422, RS232, and X.21. The default setting for this field is V.35.
explains the options for the Sync Port Type.
Sync Port Type
RS422
RS232
V.35
X.21
RS422
RS422
RS422
RS422
Table 16 Sync Port Types
Interface
Type
Cable Type
Cabletron
Part Number
RS449
RS232
V.35
RS449
RS232
V.35
9380120
9380122
9380121
X.21
RS530
RS530A
RS530 Alt A
X.21
RS530
RS530A
RS530 Alt A
9380123
9380124
9380126
9380125
RS530A Alt A RS530A Alt A 9380127
CSX400 and CSX400-DC User’s Guide 89
CSX400 Configuration with QuickSET
Sync Clock Speed — Displays your configured receive clock speed. The default setting for this field is 64000 bits per second. The information necessary for you to set this field is normally determined by the service provider. Select the down arrow button to make your selection from the list of clock speeds using the information provided by your service provider (if it is not listed, type the value in).
Sync Flow Control —
Ready (DSR) signals.
Displays the source of the Clear To Send (CTS) and the Force Data Set
The CTS signal is an input to the CSX400. The CSX400 can either use or ignore the CTS signal.
Clicking on the box indicates that the CSX400 ignores the CTS signal from an external DCE (Data
Communications Equipment) and forces the signal high. The off setting indicates that the CTS signal is received from an external DCE. The default setting is off.
The DSR signal is an input to the CSX400. Clicking on the box indicates that DSR signal is internally forced high. The off setting indicates that the DSR signal is received from an external
DCE. The default setting is off.
Protocol — Displays the active protocol for the Wide Area Sync port. The selections for this field are either Frame Relay and PPP. The default setting for this field is PPP.
Link Management Protocol — If Frame Relay is the selected protocol, this field displays Q.933
Annex A and T1.617 Annex D. The default for Frame Relay is T1.617 Annex D. This field is grayed out and not used for PPP.
Once the Wide Area Synchronous configuration is complete, click on the Next>> button, and go to the
Bridging and Routing Configuration
section of this guide.
90 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Wide Area DDS Configuration Window
The Wide Area DDS configuration window shown in
displays after clicking on the
Next>> button in the Ethernet 1 and 2 configuration window or the Wide Area Frame Relay Time
Slot and PPP configuration windows, depending on whether you have installed one or two WPIMs in the CSX400, and the order in which you are configuring them.
This section explains how to configure the CSX400 Wide Area DDS interface using QuickSET.
NOTE
Figure 31 Wide Area DDS Configuration Window
The service provider (i.e., AT&T, Sprint, MCI, etc.) determines the settings for
Table 17 . Consult the service provider for the correct settings.
CSX400 and CSX400-DC User’s Guide 91
CSX400 Configuration with QuickSET
Table 17 shows the line configuration information normally determined by your service provider.
The CSX400 factory default settings are in bold.
Table 17 Telco Configuration Information
Configuration Information
Required by User
Configuration Information
Supplied by Service Provider
DDS Line Mode
DDS Clock Source
DDS Loop Back
DDS-PRI or DDS-CC
Loop-Timing or Local-Timing
No Loop or Line Loop
This section describes the fields in the Wide Area DDS configuration window.
DDS Line Mode — Displays the DDS Line Mode. The selections for this field are DDS-PRI 56K
(primary) and DDS-CC 64K (clear channel). This information is determined by the service provider. The default setting is DDS-PRI.
DDS Clock Source — Displays the DDS clock source. The selections for this field are either
Loop-Timing or Local-Timing. The Loop-Timing setting allows the CSX400 to receive its timing information from the service provider. The Local-Timing setting allows the CSX400 to generate its timing information internally. If DDS-CC 64K was chosen for the DDS Line Mode then this field must be set to Loop-Timing. The default setting for this field is Loop-Timing.
DDS Loop Back — Displays the internal loopback as either Line Loop or No Loop. Line Loop is reserved for network diagnostics only. The default setting is No Loop.
Protocol — Displays the active protocol for the DDS WAN port. The selections for this field are
Frame Relay or PPP. The default setting for this field is PPP.
Link Management Protocol — If Frame Relay is the selected protocol, this field displays Q.933
Annex A and T1.617 Annex D. The default for Frame Relay is T1.617 Annex D. This field is grayed out and not used for PPP.
Once the Wide Area DDS configuration is complete, click on the Next>> button, and go to the
Bridging and Routing Configuration
section of this guide
92 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Wide Area HDSL Configuration Window
The Wide Area HDSL configuration window shown in Figure 32 displays after clicking on the
Next>> button in the Ethernet 1 and 2 configuration window or the PPP-HDSL configuration window.
This section explains how to configure the CSX400 Wide Area HDSL interface using QuickSET.
NOTE
Figure 32 Wide Area HDSL Configuration Window
The wiring provider (i.e., Internet Service Provider (ISP) contractor, etc.) determines the settings for
Table 18 . Consult the service provider for the correct settings.
CSX400 and CSX400-DC User’s Guide 93
CSX400 Configuration with QuickSET
Table 18 shows the line configuration information normally determined by your wiring provider.
The CSX400 factory default setting is in bold.
Table 18 Telco Configuration Information
Configuration Information
Required by User
HDSL Transmit Clock Source
Configuration Information
Supplied by Service Provider
Slave or Master
This section describes the fields in the Wide Area HDSL configuration window.
HDSL Transmit Clock Source — Displays the HDSL Transmit Clock Source. Click on the radio button to select either the Slave or Master option. The default setting is Slave.
Protocol — Displays the active protocol for the HDSL WAN port. The selections for this field are either HDLC or Point-to-Point (PPP). The default setting for this field is PPP.
Once the Wide Area HDSL configuration is complete, click on the Next>> button, and go to the
Wide Area HDSL Time Slot Configuration Window section.
94 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Wide Area Frame Relay Time Slot Configuration Window
The Wide Area Frame Relay Time Slot configuration window shown in Figure 33 displays when
you click on the Next>> button in the Wide Area T1, E1, or DI configuration windows when
Frame Relay is chosen as the WAN Protocol.
Figure 33 Wide Area Frame Relay Time Slot Configuration Window
The following section defines the fields in the Wide Area Frame Relay Time Slot configuration window.
Time Slots — A full line consists of 24 Time Slots (T1 and DI) or 31 Time Slots (E1), each capable of up to 64 Kbps throughput. If you are leasing an entire line from your service provider, you may select all the Time Slots by clicking the Select All button. A “check mark” displays in the selected box. If you have leased a portion of a fractional T1 or E1 line, the service provider tells you which Time Slots are allocated for your use. In this case, select only those Time Slots.
CSX400 and CSX400-DC User’s Guide 95
CSX400 Configuration with QuickSET
NOTE
If you are configuring a WPIM-DI Time Slot table, any available Time Slots that are not checked are mapped to the DI Interface. In other words, If you lease an entire T1 line, any Time Slots that are not selected in the Frame Relay configuration window are used by the device connected to the DI interface.
Once the Wide Area Frame Relay Time Slot configuration is complete, click on the Next>> button, and go to the
Bridging and Routing Configuration section.
Wide Area PPP Time Slot Configuration Window
The Wide Area PPP Time Slot configuration window shown in
Figure 34 displays when you click
on the Next>> button in the Wide Area T1, E1, and DI configuration windows when PPP is chosen as the WAN Protocol.
Figure 34 Wide Area PPP Time Slot Configuration Window
96 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
The following section defines the Time Slots field in the Wide Area PPP Time Slot configuration window.
Time Slots — A full line consists of 24 Time Slots (T1 and DI) or 31 Time Slots (E1) that are each capable of up to 64 Kbps throughput. Using the PPP Protocol, up to 24 interfaces (T1 and DI) or 31 interfaces (E1) can be assigned to the WAN link. Using the pull-down menu to the right of each Time Slot field, select the interface number that you wish to assign to the Time Slot.
NOTE
If you are configuring a WPIM-DI Time Slot table, any available Time Slots that are set to “00” are mapped to the DI Interface. In other words, If you lease an entire T1 line, any Time Slots that are not used in the Wide Area PPP Time Slot configuration window are used by the device connected to the DI interface.
NOTE
The interface numbers available in the pull-down menu are assigned in the Wide Area
T1, E1, and DI configuration windows. Selecting the Add Interface button or the
Delete Interface button allows available interface numbers to be added or deleted from each pull-down menu.
Once the Wide Area PPP Time Slot configuration is complete, click on the Next>> button, and go
to the Bridging and Routing Configuration window.
CSX400 and CSX400-DC User’s Guide 97
CSX400 Configuration with QuickSET
Wide Area HDSL Time Slot Configuration Window
The Wide Area HDSL Time Slot configuration window shown in Figure 35 displays when you
click on the Next>> button in the Wide Area HDSL configuration window.
Figure 35 Wide Area HDSL Time Slot Configuration Window
The following section defines the Time Slots field in the Wide Area HDSL Time Slot configuration window.
Time Slots — A full line consists of 24 Time Slots, each capable of up to 64 Kbps throughput. If you are leasing a two pair from your service provider, you may select all the Time Slots by clicking the Full button. A “check mark” displays in the selected box. If you have leased one pair of a fractional line, click on the Fractional button to select the first 12 Time Slots.
98 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Once the Wide Area HDSL Time Slot configuration is complete, click on the Next>> button, and go to the
Bridging and Routing Configuration window.
Bridging and Routing Configuration
Once all the necessary network information is collected for the WAN, the CSX400 can be configured for inverse multiplexing or bridging and/or routing.
Bridging and Routing Configuration Window
The first Bridging and Routing configuration window shown in Figure 36 displays after clicking
on the Next>> button at the bottom of the Wide Area (Frame Relay, PPP, or HDSL) Time Slot configuration window or the Wide Area (Sync or DDS) configuration window.
Figure 36 Bridging and Routing Configuration Window
CSX400 and CSX400-DC User’s Guide 99
CSX400 Configuration with QuickSET
This section describes the fields in the first Bridging and Routing configuration window.
Inverse Mux (Multiplex) Configuration — This function lets you balance your LAN traffic between two T1 WAN ports, and is used with Point to Point Protocol (PPP) or HDLC protocol.
QuickSET automatically sets the WAN Frame Type to Encapsulated Ethernet when you use the
Inverse Mux configuration. When you select the Inverse Mux check box, bridging, IP routing, and
IPX routing functions are all disabled. The WAN device at the other end of the WAN link(s) must be a Cabletron Systems device, capable of receiving the balanced WAN traffic.
NOTE
The Inverse Mux function is enabled or disabled through QuickSET, not Local
Management. Statistics regarding the Inverse Mux configuration are accessed via the
imux MIB Navigator command. See
Chapter 9 , MIB Navigator , for more information.
MAC Bridging — This field allows you to specify whether the CSX400 bridges traffic. Click on the check box to turn MAC Bridging on.
Spanning Tree Protocol — This field is grayed out until MAC Bridging is turned on. It allows you to configure the CSX400 to use the Spanning Tree Protocol, which lets the remote device check for bridging loops, and other sites that use the Spanning Tree Protocol. Click on the check box to turn on Spanning Tree Protocol.
IP Routing — The IP Routing check box allows you to turn on/off IP Routing. Click on the check box to turn on IP Routing.
IPX Routing — The IPX Routing check box allows you to turn on/off IPX Routing. Click on the check box to turn IPX Routing on.
External Ethernet 1 Network # — This field displays the IPX network number assigned to the external Ethernet network on Ethernet port 1. It is grayed out until IPX Routing is turned on.
External Ethernet 2 Network # — This field displays the IPX network number assigned to the external Ethernet network on Ethernet port 2. It is grayed out until IPX Routing is turned on.
Frame Type — This field is grayed out until IPX Routing is turned on. It allows you to select the type of IPX frame in which packets are encapsulated for transmission. Select one of the four available frame types.
100 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Firewall Configuration Window
The Firewall configuration window shown in
displays after clicking on the Firewall... button in the first Bridging and Routing configuration window. The Firewall configuration window is used to configure an Access Control List (ACL), and to allow or deny specified IP addresses to communicate through the CSX400.
The Access Control List option allows you to create access control lists that restrict traffic to, from, or between specific IP hosts, subnets, or networks. You can configure access control restrictions based on the following:
• The source, destination, or a combination of the source and destination address of a packet.
• The upper layer protocol type of a packet such as TCP, UDP, ICMP, or all TCP/IP protocols.
• The TCP or UDP port number of a packet.
When an IP Access Control List (ACL) is enabled on a router port, each packet forwarded out this port is first checked against the ACL. If the address(es) of a packet match the address(es) in the first filter in the list, the packet is permitted or denied as specified by that filter. If there is no match, the packet is checked against the second filter, and so on, until a match is found, or until the packet has been checked against all of the filters in the list. If the packet does not match any of the filters, then the packet is permitted to pass through the port.
CSX400 and CSX400-DC User’s Guide 101
CSX400 Configuration with QuickSET
Figure 37 Firewall Configuration Window
The following definitions explain the fields in the Firewall configuration window.
NOTE
The Add Firewall button clears the fields in the Firewall configuration window, allowing you to type in the fields as necessary. The Apply Changes button adds the newly entered filter to the Access Control List.
ACL (Access Control List) — The Access Control List number is a number assigned to a specific list of sequence numbers.
Sequence — A number assigned to individual access filters in an access list. As only one IP
Access Control List can be applied to each port, a single list often includes several access control filters. Each filter permits or denies access to or from a certain host, subnet, or network. When an access control list contains multiple filters, the filters are referenced in order of their sequence numbers.
102 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Source IP — The Source IP field displays the IP address of the source device accorded the permissions set in the permissions field. To set permissions for a source device, place the cursor in the Source IP field and type the IP address of the source that you wish to set permissions.
Source Mask — Displays the mask for the Source IP address specified in the Source IP field. To set the mask for the specified source IP address, place the cursor in the Source Mask field and type the mask.
The default Mask for both the source and destination addresses is 0.0.0.0, which masks the entire address, causing all addresses to match the filter. In other words, the default access control list allows all traffic to pass. Entering a mask of 255.255.255.255 causes only packets matching the exact address you have entered to match the filter.
For a Class C address, entering a mask of 255.255.255.0 causes packets with the same class C subnet as the IP address to match, thereby causing the access control filter to apply to all hosts on this particular subnet.
Dest IP — The Dest IP field displays the IP address of the destination device accorded the permissions set in the permissions field. To set permissions for a certain destination device, place the cursor in the Dest IP field and type the IP address of the destination for which you wish to set permissions.
Dest Mask — Displays the mask for the Destination IP address specified in the Dest IP field. To set the mask for the specified destination IP address, place the cursor in the Dest Mask field and type the mask.
Protocol — Use this pull-down list to select the upper layer protocol that you want to apply to the access control filter. Each access control filter can apply to traffic for all protocols included in the
TCP/IP suite, or just to traffic for a single protocol.
Permission — Use this pull-down list to set the permissions for the specified control filter.
Options for this field include permit, deny, permit bi-directional, or deny bi-directional. Choosing permit allows the specified packets to be forwarded, while choosing deny blocks the specified packets. Choosing permit bi-directional or deny bi-directional either permits or denies traffic to and from a specified source or destination.
CSX400 and CSX400-DC User’s Guide 103
CSX400 Configuration with QuickSET
Port — Enter the port number in this field to create an access control filter that applies only to
traffic for a specific TCP or UDP service. Table 19 and Table 20 supply a list of the standardized
TCP and UDP port numbers.
Table 19 TCP Services Port Numbers
TCP Services
FTP (File Transfer Protocol) -data
FTP
TELNET (Terminal Connection)
SMTP (Simple Mail Transport Protocol) 25
Time 37
Host Name Server
Domain Name Server
42
53
20
21
23
Finger
HTTP
DCP (Device Control Protocol)
79
80
93
Port # TCP Services Port #
Host Name (NIC Host Name Server)
X.400 Mail Service
X.400 Mail Sending
AUTH Authentication Service
UUCP-PATH Service
NNTP (USENET News Transfer Protocol)
PWDGEN (Password Generator Protocol)
101
103
104
NETBIOS-SSN (NETBIOS Session Service) 139
HTTPS (Secure) 443
113
117
119
129
Table 20 UDP Services Port Numbers
UDP Service
Time
Host Name Server
Domain Name Server
TACACS-Database Service
Bootstrap Protocol Server
Port #
37
42
53
65
67
UDP Service
Bootstrap Protocol Client
Trivial File Transfer
Sunrpc (NIS)
NETBIOS Name Server
NETBIOS Datagram Server
Port #
68
69
111
137
138
When you have finished making changes, click on the Apply Changes button. Once the Firewall configuration is complete, click on the OK button to return to the Bridging and Routing configuration window.
Once the first part of the Bridging and Routing configuration is complete, click on the Next>> button, and go to the second Bridging and Routing (WAN Frame Type) configuration window.
104 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Bridging and Routing (WAN Frame Type) Configuration Window
The second Bridging and Routing (WAN Frame Type) window shown in Figure 38 displays after
clicking on the Next>> button at the bottom of the first Bridging and Routing configuration window. This window is used to select a WAN Frame Type for each interface.
Figure 38 Bridging and Routing (WAN Frame Type) Configuration Window
The Bridging and Routing window displays fields for each interface number and its associated
WAN Frame Type. Select the WAN Native frame type for router to router communication. Select the Encapsulated Ethernet or Encapsulated Ethernet SNAP frame types for router-to-bridge, or bridge-to-bridge communication.
CSX400 and CSX400-DC User’s Guide 105
CSX400 Configuration with QuickSET
To change the WAN Frame Type information, scroll through the list of interface entries, and select the interface number you wish to modify by pressing the arrow button on the left side of the
Interface # field and press the Modify... button. The WAN Frame Type window displays.
The WAN Frame Type window shown in
allows you to select one of three frame types to be used over the WAN for each interface: Native WAN, Encapsulated Ethernet, and
Encapsulated Ethernet SNAP. Select the WAN Frame Type that you wish to enable by clicking the appropriate radio button. When you are done, click the OK button. The OK button returns you to the Bridging and Routing (WAN Frame Type) configuration window.
Figure 39 WAN Frame Type Configuration Window
Once the Bridging and Routing (WAN Frame Type) configuration is complete, click on the
Next>> button, and go to the
section.
106 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Routing Configuration Window
The (IP/IPX) Routing configuration window shown in
Figure 40 displays after clicking on the
Next>> button in the second Bridging and Routing (WAN Frame Type) configuration window.
Figure 40 Routing Configuration Window
This section describes the fields in the (IP/IPX) Routing configuration window. Refer to the
Routing Configuration section to configure the CSX400 for IP routing. Otherwise, refer to IPX
Routing Configuration section to configure the CSX400 for IPX routing.
CSX400 and CSX400-DC User’s Guide 107
CSX400 Configuration with QuickSET
IP Routing Configuration
This section describes the fields in the IP Routing Configuration section of the Routing configuration window.
Interface # — Displays an interface number assigned an IP subnet.
Remote LAN Subnet — Displays the IP subnet assigned to the interface number.
Subnet Mask — Displays the Subnet Mask assigned to the interface number.
Next Hop — The Next Hop is the IP address of the IP port of the next router (in the direction of the subnet that you are defining).
Default Route... — Displays the Default Route window. You can select one interface to be a default route. A default route forwards all packets that are not defined in the routing table to the interface defined in the Default Route window (Unnumbered Routing Only). To set up a default route in “Numbered Mode” communication, click the Add Route button and enter IP Subnet
000.000.000.000, and Subnet Mask 255.255.255.255. Then use the NEXT HOP window to enter the IP Address of the router you wish to designate as the default route.
Add Route... — This button allows you to add a route and to configure the CSX400 to forward only those packets from the specified route.
Delete — This button allows you to delete a route
Advanced — This button allows you to access the Advanced Routing configuration window.
IPX Routing Configuration
This section describes the fields in the IPX Routing Configuration section of the (IP/IPX) Routing configuration window that is used to assign an IPX network number.
Interface # — Displays all interface numbers which can be assigned an IPX network number.
Network # — Displays the active IPX network number assigned to an interface.
Host Map... — The IPX Host Map button takes you to the IPX Host Map window. IPX Host Map entries are used for IPX routing in Frame Relay mode only.
Modify... — Use this button to change an entry in the IPX Routing Configuration window. Select the interface number to modify by clicking on the tab to the left of the interface number.
108 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Host Map Window
The Host Map window shown in
displays after clicking on the Host Map... button in the (IP/IPX) Routing configuration window. Host Map entries are used for IPX routing using
Frame Relay Protocol only. The IPX Host Map is a database of remote IPX hosts, defined
(generally) by the WAN Network number and MAC Address, and (more specifically) by the
Interface Number and Data Link Connection Identifier (DLCI). The DLCI and Interface Number define the switched connection to the Telco control office. Enter the remote WAN MAC address and the remote Router’s WAN Network number.
Figure 41 Host Map Window
This section describes the fields in the IP Advanced configuration window.
Interface # — Displays the active interface number. The interface number is a two-digit decimal number related to the Frame Relay Time Slot.
DLCI — Displays the Data Link Connection Identifier. Use this field to enter the DLCI, which is a four-digit decimal number corresponding to the WAN virtual circuit connection to the Telco control office.
WAN Network # — Displays the active IPX network number of the WAN connection. Use this field to enter the WAN Network number.
CSX400 and CSX400-DC User’s Guide 109
CSX400 Configuration with QuickSET
Remote MAC Address — Displays the remote Ethernet MAC address. Use this field to enter the remote MAC address of the device on the other end of the WAN link.
Apply Changes — list.
Use this button to add the configured Host Map entry to the IPX Host Map
Add Host/Delete Host — These buttons allow you to add or delete a host and to configure the
CSX400 to forward only those packets from the specified host. Use these buttons to add or delete an entry in the Host Map.
When you have finished making changes, click on the Apply Changes button. Click the OK button to exit the Host Map window and return to the (IP/IPX) Routing Configuration window.
Once your CSX400 configuration is complete, click on the Save button to save any configuration changes you have made. The Congratulations window displays. Click on the OK button to exit
QuickSET.
110 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Advanced Routing Configuration Window
The Advanced Routing configuration window shown in Figure 42 displays after you click on the
Advanced button in the (IP/IPX) Routing configuration window. Use this window to enable RIP routing, configure a Dynamic Host Configuration Protocol (DHCP) server on the CSX400, set an
IP address for a remote DHCP server, or set up Network Address Translation. If you wish to run your WAN connection in Numbered Mode, enter the Local WAN IP Address Subnet Mask for
Numbered Mode or leave these fields blank for Unnumbered Mode.
Figure 42 Advanced Routing Configuration Window
CSX400 and CSX400-DC User’s Guide 111
CSX400 Configuration with QuickSET
Advanced IP Routing Settings
This section describes the fields for the Advanced IP Routing Settings of the Advanced Routing configuration window.
Interface # — Displays the active interface number.
Local WAN IP Address — Set this value only if you are going to use numbered mode. In numbered mode, the Local WAN IP address is the IP address of the WAN link leading into the
Telco control office. A Subnet Mask is required for this IP address before you can use this link.
Subnet Mask — Displays the subnet mask for the Local WAN IP address.
Modify — Use this button to change an entry in the Advanced IP Routing Settings box.
Advanced IP Routing Options
This section describes the fields for the Advanced IP Routing Options of the Advanced Routing configuration window.
Enable RIP — Selecting this function enables the sending and receiving of Routing Information
Protocol packets. Routing Information Protocol is used in IP for broadcasting open path information between routers to keep routing tables current.
Redirector Window
The Redirector window shown in Figure 43
displays after clicking on the Redirector... button in the Advanced Routing configuration window. The Redirector window is used to set up an IP address for a remote Dynamic Host Configuration Protocol (DHCP) server.
Figure 43 Redirector Window
112 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
DHCP Settings Configuration Window
The DHCP Settings configuration window shown in
Figure 44 displays after clicking on the
DHCP Server... button in the Advanced Routing configuration window. The DHCP Settings configuration window is used to configure the DHCP settings for the CSX400.
Figure 44 DHCP Settings Configuration Window
CSX400 and CSX400-DC User’s Guide 113
CSX400 Configuration with QuickSET
The following definitions explain the fields in the DHCP Settings configuration window:
DHCP Server is Enabled — Check this box to allow the CSX400 to act as a DHCP server.
DHCP IP Address Pool — A set of contiguous IP addresses that can be assigned by the CSX400 to devices requesting an IP address.
Default Gateway — A location to send any packets that are not assigned to your subnet.
Subnet Mask — The subnet mask for the default gateway (automatically set).
Lease Timeout — Used to designate the amount of time the IP addresses in the pool can be used before they become invalid. Click on the pull-down menu to view a list of available leased timeout intervals.
NOTE
Selecting Never allows you to keep your DHCP assigned IP address until the next time you boot up your PC.
DNS Settings — server.
Allows you to set up an IP address and a domain name for a Domain Name
WINS Servers — to IP addresses.
Windows Internet Name Service (WINS) resolves NETBIOS computer names
Server IP Address — Used to enter the IP address of your WINS server.
114 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
NAT Settings Configuration Window
The Network Address Translation (NAT) Settings configuration window shown in
displays after clicking on the NAT Settings... button in the Advanced Routing configuration window. The NAT Settings configuration window is used to set up Network Address Translation on Ethernet ports 1 and 2.
Figure 45 NAT Settings Configuration Window
CSX400 and CSX400-DC User’s Guide 115
CSX400 Configuration with QuickSET
The following definitions explain the fields in the NAT Settings configuration window.
Ethernet address translation to Interface # — This pull-down menu is used to disable (OFF) or enable NAT for an interface number. To enable NAT click the pull-down menu button and select an interface number to run NAT through.
Add Proxy... — Allows you to add NAT proxy servers. Click the Add Proxy... button and an
Add NAT Proxy Server window (
Figure 46 ) will appear. Enter an IP Address, and select a Port
number/type and a Protocol for each server entry.
Delete Proxy... — Allows you to delete NAT proxy servers.
Figure 46 Add NAT Proxy Server Window
Once your CSX400 Advanced Routing configuration is complete, be sure to save any changes you make. Click on the Next>> button in the Advanced Routing configuration window to return to the
(IP/IPX) Routing configuration window.
116 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
QuickSET Pull-Down Menus
The File, Firmware Upgrade and Advanced Configuration QuickSET pull-down menus allow you to store and restore configurations, initiate TFTP/BootP Services, and configure Compression and
Congestion Settings for your CSX400.
File Menu
This section describes the pull-down menu options from the File menu as shown in
Figure 47 File Menu
CSX400 and CSX400-DC User’s Guide 117
CSX400 Configuration with QuickSET
Store Configuration — The Store Configuration window shown in
clicking on the File pull-down menu and selecting Store Configuration at the top of any
QuickSET configuration window. The Store Configuration window stores the entire
CyberSWITCH configuration to a file name and drive that you specify.
Figure 48 Store Configuration Window
Restore Configuration — The Restore Configuration window shown in
clicking on the File pull-down menu and selecting Restore Configuration at the top of any
QuickSET configuration window. The Restore Configuration window allows you to load your stored configuration from a drive into QuickSET where it can be loaded into your CyberSWITCH and saved.
Figure 49 Restore Configuration Window
118 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Firmware Upgrade Menu
This section describes the pull-down menu option available from the Firmware Upgrade menu as shown in
Figure 50 Firmware Upgrade Menu
CSX400 and CSX400-DC User’s Guide 119
CSX400 Configuration with QuickSET
TFTP/BootP Services —
The TFTP/BootP Services window shown in Figure 51 displays after
clicking on the Firmware Upgrade pull-down menu and selecting TFTP/BootP Services at the top of any QuickSET configuration window. The TFTP/BootP Services window allows you to access a TFTP (Trivial File Transfer Protocol) server or BootP server to download the latest version of CSX400 firmware.
Figure 51 TFTP/BootP Services Window
120 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
This section describes the modifiable fields of the TFTP /BootP Services window:
IP Address — The IP Address field shows the IP Address of the CSX400 to which you are upgrading the firmware.
Community — The Community field allows you to enter the password of your CSX400.
Gateway IP Address — Use the Gateway IP Address field to enter the IP Address of the server acting as a gateway between the CSX400 and the TFTP server.
TFTP Server IP Address — running this utility.
The TFTP Server Address indicates the IP address of the PC
File Name — The File Name field indicates the location and name of the firmware image you are putting on your CSX400.
DownLoad — The DownLoad button starts the firmware download to your CSX400.
CSX400 and CSX400-DC User’s Guide 121
CSX400 Configuration with QuickSET
Advanced Configuration Menu
This section describes the pull-down menu options available from the Advanced Configuration menu as shown in
.
Figure 52 Advanced Configuration Menu
122 CSX400 and CSX400-DC User’s Guide
CSX400 Configuration with QuickSET
Compression and Congestion Window
The Compression and Congestion window shown in
Figure 53 displays after you click on the
Advanced Configuration pull-down menu and select Compression & Congestion at the top of any QuickSET configuration window.
Figure 53 Compression and Congestion Window
The Compression and Congestion window allows you to enable data compression on each interface. Data compression allows the size of the data being sent on a WAN link to be minimized, making the WAN link more efficient. To use data compression, the CSX400 must first be fully configured and connected to a live WAN link, and compression must be configured on any remote
WAN device(s). Using software compression, the CSX400 supports up to four DS0s (256 Kbps) per WPIM. With the optional hardware compression module installed, the CSX400 supports data compression on all DS0s, which is equivalent to two full T1 lines. For more information on the
hardware data compression module (CSX-COMP/ENCR) refer to Chapter 2 ,
CSX400 and CSX400-DC User’s Guide 123
CSX400 Configuration with QuickSET
The following defines the fields in the Compression and Congestion window.
Interface — Displays the available, pre-configured interface numbers.
Compression — Displays the status of data compression for a specific interface. Options for this field are either on (box shows a check mark) or off.
The following defines the fields for Frame Relay only:
Committed # Burst — Displays the Committed Burst size, which is the maximum amount of data a user may offer to the network during a calculated time interval. Data is guaranteed not to be discarded by the network.
Excess # Burst — Displays the Excess Burst size, which is the maximum amount of data by which a user can exceed the Committed Burst size. This data is not guaranteed to be passed by the network.
Throughput — Displays the maximum bandwidth of your WAN connection.
To turn data compression on or off for a specific interface, click on the interface number that you wish to configure in the compression scroll list, then click the compression check box. Clicking the
Apply Changes button applies the changes to the interface.
Once compression configuration is complete, click on the Save button to save any changes you make, then click on the Exit button to exit the Compression and Congestion window.
124 CSX400 and CSX400-DC User’s Guide
8
General Configuration Using Local
Management
This chapter explains how to access and manage the CSX400 and its attached segments through a
TELNET connection. A general working knowledge of basic network operations and an understanding of management applications is helpful prior to using Cabletron Systems Local
Management.
This chapter describes how to perform the following:
• Access the CSX400 through a TELNET application
• Identify and operate the types of fields used by Management
• Navigate through Management fields and menus
• Use Management screens to perform management operations
Chapter Organization
The following list summarizes the organization of this chapter:
Local Management Overview outlines the contents of this chapter, provides an overview of
Local Management, and explains how to use the management screens.
describes how to access the Main Menu screen and navigate through the Local Management screens.
describes how to use the System Level screen, its functions, and operations.
explains how to control access to the CSX400 by assigning community names.
SNMP Traps Screen explains how to configure the CSX400 to send SNMP traps to multiple
network management stations.
Flash Download Screen describes how to download new firmware to the CSX400.
describes how to configure the CSX400 for bridge functions.
IP Configuration Screen describes how to configure the CSX400 for IP routing functions.
CSX400 and CSX400-DC User’s Guide 125
General Configuration Using Local Management
IPX Configuration Screen describes how to configure the CSX400 for IPX routing functions.
WAN Setup describes how to configure the CSX400 for a Wide Area Network (WAN) interface.
NOTE
If you have a WPIM-HDSL installed in your CSX400, refer to the WAN Setup section of this chapter for configuration information. For all other WPIMs, refer to your specific
WPIM(s) Local Management Guide for information on this screen .
Local Management Overview
Cabletron Systems Local Management is a management tool that allows a network manager to perform the following tasks:
• Configure interconnected devices to form a network.
• Monitor the performance of the network.
• Control user access to the network and its components for the purpose of security.
Management Agent
The management agent is a process within the CSX400 that collects information about the operational performance of the managed network. Local Management communicates with the management agent for the purpose of issuing management commands to network devices.
Local vs. Remote Management
Network management applications are usually described as either local or remote management applications. A Local Management application resides within the circuits of the CSX400 management agent and is accessible by making a TELNET connection through one of the two
EPIM ports located on the front panel of the device. Remote management applications such as
Cabletron Systems SPECTRUM, SPECTRUM Element Manager, or QuickSET run in another device that provides management services. This allows you to perform network management from a remote location.
126 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Local Management Screen Elements
There are five basic field elements shown in the Local Management screen in Figure 54
.
SAVED OK
Local Management
EVENT MESSAGE FIELD
DISPLAY FIELDS
INPUT FIELDS
SELECTION FIELDS
Flash Image Version XX.XX.XX
System Date:
01/23/96
Host IP Address
Subnet Mask
Phys Address
COM 1 Application:
COM 2 Application:
000.000.000.000
255.255.0.0
00-00-1D-16-26-F8
[LM]
[UNASSIGNED]
SYSTEM LEVEL
System Time: 14:23:00
Out of Band IP Addr
Default Gateway
Default Interface
0.0.0.0
NONE DEFINED
NONE DEFINED
SAVE RETURN
COMMAND FIELDS
Figure 54 Sample Local Management Screen
090836
CSX400 and CSX400-DC User’s Guide 127
General Configuration Using Local Management
The following list explains each of the basic Local Management screen fields:
Event Message Field — This field briefly displays messages that indicate if a Local
Management procedure was executed correctly or incorrectly, that changes were saved or not saved to Non-Volatile Random Access Memory (NVRAM), or that a user did not have access privileges to an application.
Table 21 describes the most common event messages. Event messages related to specific Local
Management applications are described with those applications throughout this manual.
Message
SAVED OK
NOT SAVED?--PRESS SAVE TO
KEEP CHANGES
NOTHING TO SAVE
Table 21 Event Messages
Meaning
One or more fields were modified, and saved to NVRAM.
One or more fields were modified, but not yet saved to NVRAM.
The SAVE command was executed, but nothing was saved to NVRAM.
Display Fields — Display fields cannot be edited. These fields may display information which never changes, or changes as the result of Local Management operations, user selections, or network monitoring information.
Input Fields — Input fields require keyboard characters to be entered. IP addresses, System Date, and System Time are examples of Input fields.
Selection Fields — Selection fields provide a series of possible values. Only applicable values appear in Selection fields.
Command Fields — Command fields are located at the bottom of Local Management screens.
Command fields are used to exit Local Management screens and to save Local Management entries. Command fields perform a management action simply by being selected and activated.
Only command fields can make a change to a device’s configuration.
128 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Local Management Keyboard Conventions
All key names in this manual display as capital letters. For example, the ENTER key displays as
ENTER, the Escape key displays as ESC, and the Backspace key displays as BACKSPACE.
Table 22 explains the keyboard conventions used in this manual as well as the key functions.
Key
ENTER and RETURN
ESC
SPACE bar and
BACKSPACE
Arrows
SHIFT-[+/=]
[–]
DEL
Table 22 Keyboard Conventions
Function
These selection keys perform the same Local Management function. For example, “Press ENTER” means that you can press either ENTER or
RETURN, unless this manual specifically instructs you otherwise.
This key lets you escape from a Local Management screen without saving your changes. For example, “Press ESC twice” means that you must quickly press the ESCAPE key two times to exit the Local Management screen.
These keys cycle through selections in some Local Management fields. Press the SPACE bar to cycle forward through selections and press BACKSPACE to cycle backward through selections.
These are navigation keys. Use the UP-ARROW, DOWN-ARROW,
LEFT-ARROW, and RIGHT-ARROW keys to move the screen cursor. For example, “Use the arrow keys” means to press whichever arrow key moves the cursor to the desired field on the Local Management screen.
This key combination increments values in some Local Management selection fields. For example, “Press SHIFT-[+/=]” means to hold down the SHIFT key while pressing the PLUS/EQUAL key.
This key decreases values from some Local Management selection fields. For example, “Press [–]” means to press the MINUS key.
The DEL (Delete) key removes characters from a Local Management
Selection field. For example, “Press DEL” means to press the DELETE key.
CSX400 and CSX400-DC User’s Guide 129
General Configuration Using Local Management
Navigating Within Local Management Screens
To navigate within a Local Management screen, use the arrow keys of the terminal or the workstation providing terminal emulation services. The Local Management screen cursor responds to the LEFT-ARROW, RIGHT-ARROW, UP-ARROW, and DOWN-ARROW keys. Each time you press an arrow key, the Local Management screen cursor moves to the next available field in the direction of the arrow key.
The Local Management screen cursor only moves to fields which can be selected or used for input.
This means that the cursor jumps over display fields and empty lines on the Local Management screen.
The Local Management screen cursor provides wrap-around operation. This means that a cursor located at the edge of a screen, when moved in the direction of that edge, “wraps around” to the outermost selectable item on the opposite side of the screen which is on the same line or column.
Selecting Local Management Menu Screen Items
To select items in a Local Management menu screen, perform the following steps:
1.
Use the arrow keys to highlight a menu item.
2.
Press ENTER. The selected Local Management menu screen displays.
Exiting Local Management Screens
To exit any of the Local Management screens, perform the following steps:
1.
Use the arrow keys to highlight the RETURN command at the bottom of the Local
Management screen.
2.
Press ENTER. The previous screen in the Local Management hierarchy displays.
NOTE
You can also exit Local Management screens by pressing ESC twice. This exit method does not warn you about unsaved changes and all unsaved changes are lost.
Exiting the Local Management Session
To exit from CSX400 Local Management, perform the following steps:
1.
Use the arrow keys to highlight the RETURN command at the bottom of the Local
Management screen.
2.
Press ENTER. The previous screen in the Local Management hierarchy displays.
130 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
3.
Repeat steps 1 and 2 until the Main Menu screen displays.
4.
Use the arrow keys to highlight the EXIT command at the bottom of the Main Menu screen.
5.
Press ENTER. The CSX400 Local Management Password screen displays and the Local
Management session ends.
Establishing a TELNET Connection
The CSX400 is shipped with a temporary IP Address of 192.168.254.254 so that your computer can communicate with it over your Local Area Network (LAN) through a TELNET connection.
However, to establish a TELNET connection, your computer must be on the same subnet as the
CSX400. Cabletron Systems recommends that you assign a temporary IP Address of
192.168.254.253 to your computer to ensure that both devices are on the same subnet. TELNET connections to the host device require the community name passwords assigned at the SNMP
Community Names screen or if you are doing an initial configuration, use the default password
public. Refer to the SNMP Community Names section of this manual for additional information about community names.
NOTE
See the instructions included with the TELNET application for information about establishing a TELNET session.
Local Management Screen Hierarchy
Local Management consists of a series of menu screens that provide a path to each of the Local
Management function screens. Navigate through Local Management by selecting items from the menu screen.
shows the hierarchy of the Local Management screens.
Password Main Menu
Setup Menu
System Level
SNMP Community Names
SNMP Traps
Flash Download
Bridge Setup
Router Setup
WAN Setup
IP
IPX
MIB Navigator
Figure 55 Hierarchy of Local Management Screens
IP Configuration
IP RIP
IPX Configuration
IPX RIP
IPX SAP
CSX400 and CSX400-DC User’s Guide 131
General Configuration Using Local Management
Accessing Local Management
This section explains how to access and use the Local Management menu screens. Menu screens provide a path to the setup screens and status screens.
Using the Menu Screens
Once you have accessed the CSX400 through a TELNET connection, the CSX400 Password
screen, shown in Figure 56 , displays.
CSX400 Local Management
CABLETRON Systems, Incorporated
P.O. Box 5005
Rochester, NH 03867-5005 USA
(603) 332-9400
(c) Copyright CABLETRON Systems, Inc. 19XX
Device Model Number:
Serial Number:
Functionality Level:
Flash Image Version:
BOOTPROM Version:
Board Revision:
Enter Password:
XX.XX.XX
XX.XX.XX
2012 01
Figure 56 CSX400 Password Screen
Type in your password and press ENTER. If you are doing an initial configuration, the default super-user access password is “public” or press ENTER.
NOTE
Your password is one of the community names specified in the SNMP Community
Names screen. Access to certain Local Management capabilities depends on the degree of access accorded that community name. See the SNMP Community Names section.
• If you enter a valid password, the associated access level displays at the bottom of the screen and the Main Menu screen, shown in
, displays.
132 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
• If you enter an invalid password, the cursor returns to the beginning of the password entry field.
• If no activity occurs for several minutes, the Password screen displays again, ending your current session. You must reenter the password to perform Local Management tasks.
Main Menu Screen
The Main Menu screen is the starting point from which all the Local Management screens are accessed.
Figure 57 shows the Main Menu screen.
CSX400 Local Management Flash Image Version: XX.XX.XX
MAIN MENU
SETUP MENU
MIB NAVIGATOR
EXIT
2012 02
Figure 57 Main Menu Screen
The Main Menu screen displays the following menu items:
Setup Menu — The Setup Menu provides access to Local Management screens that are used to configure the CSX400.
— The MIB Navigator is a Local Management utility that allows the user to access, monitor, and set specific Management Information Base (MIB) items within the CSX400.
Refer to Chapter 9 , MIB Navigator , for information on the MIB Navigator.
CSX400 and CSX400-DC User’s Guide 133
General Configuration Using Local Management
Setup Menu Screen
The Setup Menu screen provides access to the Local Management screens that are used to configure the CSX400. Examples of functions accessible through the Setup Menu include configuring the host IP address and Subnet Mask, assigning the SNMP community names, and configuring the SNMP trap notification.
Figure 58 shows the Setup Menu.
HSIM-W6 Local Management Flash Image Version XX.XX.XX
SETUP MENU
SYSTEM LEVEL
SNMP COMMUNITY NAMES
SNMP TRAPS
FLASH DOWNLOAD
BRIDGE SETUP
ROUTER SETUP
WAN SETUP
RETURN
2012_03
Figure 58 Setup Menu Screen
The Setup Menu screen displays the following menu items:
System Level — for the CSX400.
The System Level screen allows you to configure basic operating parameters
SNMP Community Names — The SNMP Community Names screen allows you to change or review the community names used as access passwords for local management operation.
SNMP Traps — The SNMP Traps screen provides display and configuration access to the table of IP addresses used for trap destinations and associated community names.
134 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Flash Download — The Flash Download screen allows you to download a firmware image from a TFTP server to the CSX400.
Bridge Setup — The Bridge Setup screen allows you to select a Spanning Tree protocol and enable/disable switch ports.
Router Setup — The Router Setup screen accesses two other screens that provide general IP or
IPX routing configuration and allow you to enable or disable the Routing Information Protocol
(RIP) and the Service Advertisement Protocol (SAP) features.
WAN Setup – The WAN Setup menu item accesses two other screens that provide WAN physical configuration and WAN Interface configuration access to enable a WAN link to be set up.
NOTE
If you have a WPIM-HDSL installed in your CSX400, refer to the WAN Setup section of this chapter for configuration information. For all other WPIMs, refer to your specific
WPIM(s) Local Management Guide for information on configuring the CSX400 for a
Wide Area Network Interface .
System Level Screen
The System Level screen displays the physical address (MAC address) of the CSX400 and allows you to set the following parameters:
• System Date
• System Time
• Host IP Address
• Subnet Mask
• Default Gateway
• Default Interface
CSX400 and CSX400-DC User’s Guide 135
General Configuration Using Local Management
Access the System Level screen (
Figure 59 ) from the Setup Menu screen by using the arrow keys
to highlight the System Level option and pressing ENTER. The System Level screen displays.
CSX400 Local Management
System Date: 12/30/97
Host IP Address
Subnet Mask
Phys Address
0.0.0.0
255.255.0.0
00-00-1D-16-26-F8
COM 1 Application: [LM]
Flash Image Version XX.XX.XX
SYSTEM LEVEL
System Time: 14:23:00
Default Gateway
Default Interface
NONE DEFINED
NONE DEFINED
SAVE RETURN
2012_04
Figure 59 System Level Screen
The following definitions explain each System Level screen field. The sections which follow these definitions explain the use of these fields.
System Date — Use this field to enter the system date, as described in
System Time —
.
Use this field to enter the system time, as described in Setting the System
Host IP Address —
.
Use this field to enter the IP address of the CSX400, as described in Setting
136 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Subnet Mask — This field displays the default Subnet Mask, and allows you to enter a new value for the Subnet Mask if necessary. Subnets are logical divisions of the network that isolate groups of devices. The Subnet Mask determines how the CSX400 directs SNMP traps to a management workstation. If the CSX400 resides on the same network as the management workstation, then the
CSX400 sends SNMP traps directly to the management workstation. If the CSX400 resides on a different subnet as the management workstation, then the CSX400 sends SNMP traps to a gateway or router.
• When the management workstations designated to receive SNMP traps reside on the same network as the CSX400, use the Subnet Mask default setting for the IP address entered on the
System Level screen.
• Set a new value for the Subnet Mask when the management workstations designated to receive
SNMP traps reside on a different subnet (for example, across a gateway or router)
To set a Subnet Mask, refer to the
section.
Phys Address — physical address.
This field displays the physical address of the CSX400. You cannot modify the
Default Gateway — Use this field to enter the Default Gateway for the CSX400. When routing packets, the CSX400 uses the IP Forwarding Table to find the route to each destination address.
The IP Forwarding Table contains the routes to all networks and hosts within a certain area.
However, the IP Forwarding Table on its own cannot provide all of the routes that may be needed.
The CSX400 relies on a Default Gateway to provide the routes to destinations that are not listed in its own IP Forwarding Table. The Default Gateway is the IP address of the network device
(gateway or router) used to forward SNMP traps to a management station. The default setting for this field is NONE DEFINED. To set the Default Gateway, refer to
.
Default Interface — Use this field to select the default interface for the CSX400 Default
Gateway. The default interface is the channel which is set up to handle SNMP traps sent to an IP station that is not on the same subnet as the CSX400 in an IP routed environment. The default setting for this field is NONE DEFINED. To set the default interface for the Default Gateway of
the CSX400, refer to Setting the Default Interface .
CSX400 and CSX400-DC User’s Guide 137
General Configuration Using Local Management
Setting the System Date
The CSX400 is year 2000 compliant so that the System Date field can be set beyond the year 1999.
To set the system date, perform the following steps:
1.
Use the arrow keys to highlight the System Date field.
2.
ENTER the date in an MM/DD/YY YY format.
NOTE
When entering the date in the system date field, you do not need to add separators between month, day, and year numbers, as long as each entry uses two decimal numbers. For example, to set the date to 03/17/1997, type “03171997” in the System
Date field.
3.
Press ENTER to set the system date.
4.
Use the arrow keys to highlight the SAVE command at the bottom of the screen and press
ENTER.
If the date entered was a valid format, the Event Message field at the top of the screen displays
“SAVED OK”. If the entry was not valid, Local Management does not alter the current value and refreshes the System Date field with the previous value.
Setting the System Time
To set the system time, perform the following steps:
1.
Use the arrow keys to highlight the System Time field.
2.
ENTER the time in a 24-hour format, HH:MM:SS.
NOTE
When entering the time in the system time field, you do not need to add separators between hours, minutes, and seconds, as long as each entry uses two decimal numbers. For example, to set the time to 6:45 a.m., type “064500” in the System Time field.
3.
Press ENTER to set the system time.
4.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and press
ENTER. If the time entered was a valid format, the Event Message field at the top of the screen displays “SAVED OK”. If the entry was not valid, Local Management does not alter the current value and refreshes the System Time field with the previous value.
138 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Setting the Host IP Address
To set the host IP address, perform the following steps:
1.
Use the arrow keys to highlight the Host IP Address field.
2.
Enter the IP address using Decimal Dotted Notation (DDN) format.
For example: 134.141.25.17
3.
Press ENTER. If the IP address entered was a valid format, the cursor returns to the beginning of the Host IP Address field. If the entry was not valid, the Event Message field displays
“INVALID IP ADDRESS OR FORMAT ENTERED”. Local Management does not alter the current value and refreshes the Host IP Address field with the previous value.
4.
Use the arrow keys to highlight the SAVE command field.
5.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
Setting the Subnet Mask
Subnets are logical divisions of the network. To change the Subnet Mask from its default value, perform the following steps:
1.
Use the arrow keys to highlight the Subnet Mask field.
2.
Enter the Subnet Mask using Dotted Decimal Notation (DDN) format. Values for each decimal can be from 0 to 255.
For example: 255.255.0.0
3.
Press ENTER. If the Subnet Mask entered was a valid format, the cursor returns to the beginning of the Subnet Mask field. If the entry was not valid, the Event Message field displays
“INVALID SUBNET MASK OR FORMAT ENTERED”. Local Management does not alter the current value and refreshes the Subnet Mask field with the previous value.
4.
Use the arrow keys to highlight the SAVE command field.
5.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
Setting the Default Gateway
To set the Default Gateway, perform the following steps:
1.
Use the arrow keys to highlight the Default Gateway field.
CSX400 and CSX400-DC User’s Guide 139
General Configuration Using Local Management
2.
ENTER the IP address of the Default Gateway using DDN format.
For example: 134.141.79.121
3.
Press ENTER. If the Default Gateway address entered was a valid format, the cursor returns to the beginning of the Default Gateway field. If the entry was not valid, the Event Message field displays “INVALID DEFAULT GATEWAY OR FORMAT ENTERED”. Local Management does not alter the current value and refreshes the Default Gateway field with the previous value.
4.
Use the arrow keys to highlight the SAVE command field.
5.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
Setting the Default Interface
To set the default interface, perform the following steps:
1.
Use the arrow keys to highlight the Default Interface field.
2.
ENTER the interface number for the Default Gateway in this field.
3.
Press ENTER. If the interface entered was a valid format, the cursor returns to the beginning of the Subnet Mask field. If the entry was not valid, the Event Message field displays
“PERMISSIBLE RANGE: 1...1”. Local Management does not alter the current value and refreshes the Default Interface field with the previous value.
4.
Use the arrow keys to highlight the SAVE command field.
5.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
140 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
SNMP Community Names Screen
This section explains how to assign community names. Community names allow you to control
Local Management access by establishing three passwords. Each password controls varying levels of access to CSX400 Local Management.
Access the SNMP Community Names screen, shown in
, from the Setup Menu screen by using the arrow keys to highlight the SNMP Community Names option and pressing ENTER.
The SNMP Community Names screen displays.
CSX400 Local Management
SNMP COMMUNITY NAMES
Community Name public public public
Flash Image Version: XX.XX.XX
Access Policy read-only read-write super-user
SAVE RETURN
2012_05
Figure 60 SNMP Community Names Screen
Community Name Access Policy
To perform any operations on the SNMP Community Names screen, you must have used the super-user community name at the User Password prompt when initiating the Local Management session. The default community name for each access level is public or press ENTER.
The following explains each of the SNMP Community Names screen fields:
CSX400 and CSX400-DC User’s Guide 141
General Configuration Using Local Management
Community Name — Displays the user-defined names through which a user accesses the
CSX400 Local Management. Any community name entered here acts as a password to Local
Management.
Access Policy — conditions are:
Indicates the access status accorded each community name. Possible status read-only — names.
This access level allows reading of device parameters not including community read-write — This access level allows editing of some device configuration parameters not including changing or viewing community names.
super-user — This access level allows full management privileges.
Setting SNMP Community Names
To set a community name, perform the following steps:
!
CAUTION
If you edit the super-user community name, be certain you do not forget it. If you do, you cannot perform Local Management functions without returning the device to its factory default configurations. This effectively erases any configuration work you have done.
1.
Use the arrow keys to highlight the community name you want to change.
2.
Type the new community name and press ENTER. The old community name is replaced by the new community name.
3.
Use the arrow keys to highlight the SAVE command field.
4.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
142 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
SNMP Traps Screen
The SNMP Traps screen, shown in
Figure 61 , allows the user to configure the CSX400 to send
traps to as many as eight remote management workstations. SNMP traps are messages about network events and device operational statistics.
Access the SNMP Traps screen from the Setup Menu screen by using the arrow keys to highlight the SNMP Traps option and pressing ENTER. The SNMP Traps screen displays.
CSX400 Local Management Flash Image Version: XX.XX.XX
Trap Destination
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
SNMP TRAPS
Trap Community Name public public public public public public public public
Enable Traps
(NO)
(NO)
(NO)
(NO)
(NO)
(NO)
(NO)
(NO)
SAVE RETURN
2012_06
Figure 61 SNMP Traps Screen
Trap Table Screen Fields
The following definitions explain each of the SNMP Traps screen fields:
Trap Destination — Use this field to enter the IP address of the management workstation designated to receive SNMP traps from the CSX400.
Trap Community Name — Use this field to enter the community name of the management workstation with the associated IP address. The community name indicates the “access level” of traps that will be forwarded to the Trap destination.
CSX400 and CSX400-DC User’s Guide 143
General Configuration Using Local Management
Enable Traps — workstation.
Use this field to enable the transmission of SNMP traps to the management
Setting the SNMP Trap Destination
Each management workstation designated to receive SNMP traps from the CSX400 must have a valid IP address and community name. To set and enable SNMP trap destination, perform the following steps:
1.
Use the arrow keys to highlight the Trap Destination field that you want to modify.
2.
Type the IP address of the management workstation designated to receive SNMP traps from the
CSX400. This address must be entered in DDN format.
For example: 134.141.25.17
3.
Press ENTER. If the IP address entered was a valid format, the cursor returns to the beginning of the Trap Destination IP address field. If the entry was not valid, the Event Message field displays “INVALID IP ADDRESS OR FORMAT ENTERED”. Local Management does not alter the current value and refreshes the Trap Destination IP address field with the previous value.
4.
Use the arrow keys to highlight the Trap Community Name field (on the same row as the Trap
Destination field).
5.
Type the community name of the management workstation. The community name indicates the
“access level” of traps that will be forwarded to the Trap destination.
6.
Press ENTER.
7.
Use the arrow keys to highlight the Enable Traps field (on the same row as the Trap
Destination and Trap Community Name you have just configured). The default setting for this field is NO.
8.
Press the SPACE bar or BACKSPACE to set the field to YES.
9.
Use the arrow keys to highlight the SAVE command field.
10.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
11.
Repeat this procedure as necessary to set each Trap Destination.
144 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Flash Download Screen
The Flash Download screen allows you to download a firmware image from a TFTP server to the
CSX400.
Access the Flash Download screen from the Setup Menu screen by using the arrow keys to highlight the Flash Download option and pressing ENTER. The Flash Download screen, shown in
NOTE
Flash download operations require a properly named download file and a properly configured download server.
CSX400 Local Management
FLASH DOWNLOAD
Download Method:
Reboot After Download:
Last Image Server IP:
Last Image File Name:
[RUNTIME]
[YES]
134.141.17.12
c:/tftpboot/csx400.hex
Flash Image Version: XX.XX.XX
Download Server IP:
Download File Name:
134.141.17.12
c:/tftpboot/csx400.hex
EXECUTE RETURN
2012_07
Figure 62 Flash Download Screen
The following definitions explain each of the Flash Download screen fields.
Download Method — Use this field to select the method you wish to use to download the firmware image to the CSX400.
CSX400 and CSX400-DC User’s Guide 145
General Configuration Using Local Management
• Reboot After Download — This field displays when the RUNTIME Download Method is chosen. Selecting YES forces the CSX400 to reboot and use the new firmware image immediately. Selecting NO allows the CSX400 to continue using the existing firmware image without interrupting network operation.
• Commit to Flash — This field displays when the BOOTPROM Download Method is chosen.
Selecting YES allows the CSX400 to continue using the existing firmware image without interrupting network operation and selecting NO allows the CSX400 to reboot and use the new firmware image immediately.
• TFTP Gateway Server IP — This field displays when the BOOTPROM Download Method is chosen. Use this field to enter the IP address of the TFTP Gateway Server.
Last Image Server IP — image to the CSX400.
Displays the IP address of the last server used to download a firmware
Last Image File Name —
CSX400.
Displays the file name of the last firmware image downloaded to the
Download Server IP — Use this field to type in the IP address of the server from which you wish to download the firmware image.
Download File Name — download to the CSX400.
Use this field to type in the file name of the firmware image you wish to
Selecting a Flash Download Method
1.
Use the arrow keys to highlight the Download Method field.
2.
Press the SPACE bar or BACKSPACE to select a flash download method.
• If you select RUNTIME, the Reboot After Download field displays.
• If you select BOOTPROM, the Commit to Flash field and the TFTP Gateway Server IP field display.
146 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
RUNTIME Download
If you select RUNTIME Download, perform the following steps:
1.
Use the arrow keys to highlight the Reboot After Download field.
2.
Press the SPACE bar or BACKSPACE to select one of the following:
• YES, if you want the CSX400 to reboot and use the new firmware image immediately.
• NO, if you want the CSX400 to continue using the existing firmware image without interrupting network operation. The CSX400 stores the new firmware image in flash memory. When you reset the CSX400, it boots from flash memory using the new image.
3.
Use the arrow keys to highlight the Download Server IP field.
4.
Type the IP address of the download server and press ENTER.
5.
Use the arrow keys to highlight the Download File Name field.
6.
Type the complete path and filename of the new image file to be downloaded. You must include all directories and subdirectories involved in accessing the file. Type the new entry over the previous entry. For example: c:\images\cyberswitch\11011.hex
7.
Press ENTER.
8.
Use the arrow keys to highlight the EXECUTE command located at the bottom of the Flash
Download screen.
9.
Press ENTER to begin the download. The CSX400 attempts to download the file using the IP address, filename, and path provided. This file is assigned to the Flash memory of the CSX400.
BOOTPROM Download
If you select a BOOTPROM Download, perform the following steps:
1.
Use the arrow keys to highlight the Commit to Flash field.
2.
Press the SPACE bar or BACKSPACE to select one of the following:
• YES, if you want the CSX400 to continue using the existing firmware image without interrupting network operation. The CSX400 stores the new firmware image in flash memory. When you reset the CSX400, it boots from flash memory using the new image.
• NO, if you want the CSX400 to reboot and use the new firmware image immediately.
3.
Use the arrow keys to highlight the Download Server IP field.
4.
Type the IP address of the download server and press ENTER.
CSX400 and CSX400-DC User’s Guide 147
General Configuration Using Local Management
5.
Use the arrow keys to highlight the Download File Name field.
6.
Type the complete path and filename of the new image file to be downloaded. You must include all directories and subdirectories involved in accessing the file. Type the new entry over the previous entry. For example: c:\images\cyberswitch\11011.hex.
7.
Press ENTER.
8.
Use the arrow keys to highlight the TFTP Gateway Server IP field.
9.
Enter the IP address of the TFTP gateway server.
10.
Use the arrow keys to highlight the EXECUTE command located at the bottom of the Flash
Download screen. The CSX400 attempts to download the file using the IP address, filename, and path provided. This file is assigned to the Flash memory of the CSX400.
148 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Bridge Setup Screen
The Bridge Setup screen enables you to select a Spanning Tree protocol and enable/disable bridge ports.
Access the Bridge Setup screen, shown in
, by using the arrow keys to highlight the
Bridge Setup option and pressing ENTER. The Bridge Setup screen displays.
CSX400 Local Management
SPANNING TREE PROTOCOL:
BRIDGE SETUP
[IEEE 802.1]
BRIDGE PORT ADMIN STATUS:
BRIDGE PORT PAIR ADMIN STATUS:
PORT 01 --> ALL PORTS
PORT XX --> PORT [02]
Flash Image Version: XX.XX.XX
[ENABLED]
[ENABLED]
SAVE BRIDGE_PORT [01] RETURN
2012_08
Figure 63 Bridge Setup Screen
Bridge Setup Screen Fields
The following list describes each of the Bridge Setup screen fields:
Spanning Tree Protocol — Use this field to select a Spanning Tree protocol. Possible selections for this field are IEEE 802.1, DEC, or NONE.
Bridge Port Admin Status — Use this field to enable or disable individual CSX400 bridge ports.
Possible selections for this field are ENABLED or DISABLED.
Bridge Port Pair Admin Status — Use this field to enable or disable bridging between bridge port pairs. For example, you can enable Port 1 to bridge traffic to all ports except Port 2.
CSX400 and CSX400-DC User’s Guide 149
General Configuration Using Local Management
Bridge_Port X — configure.
Use this command field to select the CSX400 bridge port you want to
Selecting a Spanning Tree Protocol
To select the Spanning Tree protocol to be used by the CSX400, perform the following steps:
1.
Use the arrow keys to highlight the SPANNING TREE PROTOCOL field.
2.
Press the SPACE bar or BACKSPACE to select [IEEE 802.1], [DEC], or [NONE].
3.
Use the arrow keys to highlight the SAVE command field.
4.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
Selecting the Bridge Port Administrative Status
To select the bridge port administrative status, perform the following steps:
1.
Use the arrow keys to highlight the [BRIDGE_PORT XX] field at the bottom of the Bridge
Setup screen.
2.
Press the SPACE bar or BACKSPACE to select the bridge port you want to configure. The selected bridge port displays in the Bridge Port Admin Status field.
3.
Use the arrow keys to highlight the BRIDGE PORT ADMIN STATUS: PORT X - - > ALL
PORTS [ENABLED] field.
4.
Press the SPACE bar or BACKSPACE to select ENABLE or DISABLE.
For example, the following bridge setup indicates that bridge port 01 is configured to bridge traffic to all ports:
BRIDGE PORT ADMIN STATUS: PORT 01 - - > ALL PORTS [ENABLED]
5.
Use the arrow keys to highlight the SAVE command field.
6.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
150 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Selecting the Bridge Port Pair Administrative Status
To select the bridge port pair administrative status, perform the following steps:
1.
Use the arrow keys to highlight the [BRIDGE_PORT XX] field at the bottom of the Bridge
Setup screen.
2.
Press the SPACE bar or BACKSPACE to select the bridge port you want to configure. The selected bridge port displays in the Bridge Port Pair Admin Status field.
3.
Use the arrow keys to highlight the BRIDGE PORT PAIR ADMIN STATUS: PORT X - ->
PORT [Y] field.
4.
Press the SPACE bar or BACKSPACE to select the port you want to enable or disable bridge traffic.
5.
Use the arrow keys to highlight the BRIDGE PORT PAIR ADMIN STATUS: PORT X - ->
PORT [Y] [ENABLED] field.
6.
Press the SPACE bar or BACKSPACE to select ENABLE or DISABLE.
For example, the following bridge setup indicates that bridge port 01 is configured NOT to bridge traffic to bridge port 02:
BRIDGE PORT PAIR ADMIN STATUS: PORT 01 - - > PORT [02] [DISABLED]
7.
Use the arrow keys to highlight the SAVE command field.
8.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.
CSX400 and CSX400-DC User’s Guide 151
General Configuration Using Local Management
Router Setup Screen
The Router Setup screen allows you to choose either IP or IPX routing for your CSX400.
Access the Router Setup screen, shown in
, by using the arrow keys to highlight the
ROUTER SETUP menu item in the Setup Menu and pressing ENTER. The Router Setup screen displays.
HSIM-W6 Local Management Flash Image Version XX.XX.XX
ROUTER SETUP
IP
IPX
INITIALIZE
RETURN
IP/IPX
Figure 64 Router Setup Screen
Router Setup Fields
The following list describes the Router Setup fields.
IP — Use this field to access the IP Configuration screen to configure the CSX400 for IP routing.
IPX — routing.
Use this field to access the IPX Configuration screen to configure the CSX400 for IPX
152 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
IP Configuration Screen
The IP Configuration screen enables you to access the IP General Config and IP RIP screens to configure the CSX400 for IP Routing and enable RIP on the CSX400.
Access the IP Configuration screen, shown in
Figure 65 , by using the arrow keys to highlight the
IP menu item on the Router Setup screen and pressing ENTER. The IP Configuration screen displays.
CSX 400 Local Management Flash Image Version XX.XX.XX
IP CONFIGURATION
IP General Config
IP RIP
RETURN
2012_09
Figure 65 IP Configuration Screen
IP Configuration Screen Fields
The following list describes each of the IP Configuration screen fields.
IP General Config —
CSX400 for IP routing.
Use this field to access the IP General Config screen and configure the
IP RIP — Use this field to access the IP RIP screen and enable Routing Information Protocol
(RIP) routing on the CSX400.
CSX400 and CSX400-DC User’s Guide 153
General Configuration Using Local Management
IP General Config Screen
The IP General Config screen allows you to configure the CSX400 for IP routing.
Access the IP General Config screen by using the arrow keys to highlight the IP General Config
menu item and pressing ENTER. The IP General Config screen shown in Figure 66 displays.
CSX 400 Local Management Flash Image Version XX.XX.XX
IP General Config
Router Name: IP
Version: XX.XX.XX
Status: Enabled
AdminStatusTime: 0 days 0 hours 39 min
UpTime: 0 days 0 hours 39 min
Server: 0.0.0.0
UDP Port: 37
System Level Setup
IP Routing:
Redirector:
ENABLED
FORWARD
37 of 999
UDP Type: time
Port Level Setup
Port: 1 Description: Ctron CSX400 EnetPort
MAC Address: 00-00-1D-22-46-B0
Oper Status: Enabled Framing: Ethernet
Interf. Type: ethernet-csmacd
MTU: 1500
Address: 134.141.17.177 Mask: 255.255.0.0
Network Bcast: Ones
IP Routing: ENABLED IP Forwarding: ENABLED
Address Type: Primary
Proxy ARP: DISABLED
+PORT+REDIRECTORSAVE RETURN
2012_11
Figure 66 IP General Config Screen
IP General Configuration Status Fields
The following list describes each of the IP General Config status fields. The status fields are for informational purposes only and cannot be modified.
Router Name — Displays the type of routing used.
Status — Displays the status of IP Routing.
UpTime — Displays the amount of time elapsed since the last time the CSX400 was rebooted.
Version — Displays the IP Routing version number used on the CSX400.
154 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
AdminStatusTime — the CSX400.
Displays the amount of time elapsed since an IP address was assigned to
UDP Type — Displays the User Datagram Protocol (UDP) Service to which the selected UDP
Port number corresponds.
Description — Describes the selected Port.
MAC Address — Displays the physical (MAC) address of the CSX400.
Interf. Type — Displays the type of interface used by the specified port.
Oper Status — Displays the operational status of the selected port.
IP General Configuration Fields
This section provides a general overview of the procedures required to configure the CSX400. The following list describes each of the modifiable IP General Config Screen fields.
+PORT- — Use this field to select the routing port you wish to configure.
+REDIRECTOR- — Use this field to toggle through a list of commonly used UDP port numbers.
UDP port numbers are associated with the relay agent functionality of the router.
Framing — Use this field to select the format of the frame in which IP packets are encapsulated for transmission.
MTU — Use this field to set the Maximum Transmission Unit (MTU).
IP Routing — Use this field to enable IP Routing Services.
IP Forwarding — Use this field to enable IP Forwarding.
Proxy ARP — Use this field to enable Proxy Address Resolution Protocol (ARP).
Address — Use this field to assign an IP address to the port that you wish to configure.
Mask — Use this field to set the Subnet Mask for the port that you wish to configure.
CSX400 and CSX400-DC User’s Guide 155
General Configuration Using Local Management
Selecting a Port for Configuration
Routing Services allows you to choose the ports that you want to configure for IP routing. To select a router port to configure for IP routing, complete the following steps:
1.
Use the arrow keys to highlight the PORT option.
2.
Type in the number of the port that you want to configure for IP routing and then press ENTER.
NOTE
You can type in the port number, or you can use the + PORT option at the bottom of the screen to scroll through the list of the ports on your device. To use the + PORT option, use the arrow keys to highlight the + (to go forward), or the (to go backward), and then press ENTER to scroll through the available ports in the direction you have selected. You can also use the + and - keys to scroll through the available ports.
If you type in an invalid port number, the error message “PORT NUMBER IS OUT OF RANGE” displays. Perform steps 1 and 2 again.
Entering the IP Address and Subnet Mask
All IP hosts must have an IP Address for each network interface. These addresses identify each network connection.
To enter the IP address for a router port, complete the following steps:
1.
Use the arrow keys to highlight the ADDRESS option.
2.
Type in the IP address and then press ENTER.
Once an IP address is entered, the default Subnet Mask automatically enters into the Mask field. To to change the default Subnet Mask for a router port, complete the following steps:
1.
Use the arrow keys to highlight the MASK option.
2.
Type in the Subnet Mask for the IP address that you have assigned.
Selecting the Frame Type for a Port
On each port, Frame Type specifies the format of the frame in which IP packets are encapsulated for transmission. The Frame Type options available for each router port are dependent on the type of media supported by that router port.
To select the Frame Type for a port, complete the following steps:
1.
Use the arrow keys to highlight the Framing option.
2.
Use the ENTER key to toggle the entry to the correct Frame Type for the port.
156 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
Setting the Maximum Transmission Unit (MTU)
The Maximum Transmission Unit specifies the maximum packet size for all IP packets that are transmitted.
To select the MTU for a port, complete the following steps:
1.
Use the arrow keys to highlight the MTU option under Port Level Setup.
2.
ENTER an MTU value for the media used.
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen, then press
ENTER. The message “SAVED OK” displays.
Enabling IP Routing Services on a Port
The ability to switch IP Routing Services on and off on a port-by-port basis, provides great flexibility. On the same device, some ports can be routing IP traffic while other ports are bridging it. As you are in transition from a bridged network to a routed network, this flexibility allows you to implement IP routing and test your routing configuration on a port-by-port basis. If necessary, you can temporarily disable the IP routing on any port without losing your configuration, or you can temporarily switch from IP routing back to bridging.
To enable IP Routing Services on a router port, complete the following steps:
1.
Use the arrow keys to highlight the IP Routing option under Port Level Setup.
2.
Use the ENTER key to toggle the entry to ENABLED.
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen, and then press ENTER. The message “SAVED OK” displays.
Enabling IP Forwarding on a Port
By default, IP Forwarding is disabled on each router port. Your device cannot begin forwarding IP data packets on any router port until you enable IP Forwarding on that port.
To enable IP Forwarding on a router port, complete the following steps:
1.
Use the arrow keys to highlight the IP Forwarding option.
2.
Use the ENTER key to toggle the entry to ENABLED.
CSX400 and CSX400-DC User’s Guide 157
General Configuration Using Local Management
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
Configuring the UDP Broadcast Redirector
To locate a server that can provide a particular network service, many IP hosts rely on the use of
LAN broadcasts to send UDP service requests. The UDP port number contained in the broadcast request packet identifies the service being requested.
shows the port numbers and their corresponding requested services.
UDP Port #
65
67
68
69
37
42
53
137
138
111
Table 23 UDP Port Numbers
UDP Services
Time
Host Name Server
Domain Name Server
TACACS-Database Service
Bootstrap Protocol/Dynamic Host Control Protocol Server
Bootstrap Protocol/Dynamic Host Control Protocol Client
Trivial File Transfer
NETBIOS Name Server
NETBIOS Datagram Server
Sunrpc (NIS)
The UDP Broadcast Redirector enables you to configure any Routing Services enabled device to forward the UDP packets that it receives as LAN broadcasts, directly to the appropriate server.
UDP service requests that are sent as LAN broadcasts by clients of applications such as Host
Name, Domain Name, and Bootstrap servers, can be redirected to any server on any network segment.
To configure the UDP Broadcast Redirector, complete the following steps:
1.
Use the arrow keys to highlight the UDP Port option under System Level Setup.
2.
ENTER the UDP port number of the UDP service request packets that you want to redirect
(refer to Table 23 ) and then press ENTER.
158 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
NOTE
You can type in the UDP port number, or you can use the + REDIRECTOR option at the bottom of the screen to scroll through a list of commonly used UDP port numbers.
To use the + REDIRECTOR option, use the arrow keys to highlight the + (to go forward), or the (to go backward), and then press the ENTER key to scroll in the direction that you selected.
The entry for the UDP Port option reflects the UDP port number that is currently selected. The entry for UDP Type names the UDP service to which that port number corresponds.
Enabling Proxy ARP on a Port
By default, Proxy Address Resolution Protocol (ARP) is disabled on all ports, and IP Routing
Services respond only to ARP requests addressed to its own IP address.
For one IP host to communicate with another IP host, knowledge of the target host’s MAC address must be known. To learn this MAC address, the IP host sends an ARP request packet as a LAN broadcast with the destination IP address of the target IP host. All hosts receive this broadcast and the one host that matches the target IP address responds with its MAC-layer address. However, because each subnet constitutes a separate broadcast domain and LAN broadcasts are not forwarded across routers, ARP does not work beyond a host’s local network or subnetwork. One of the primary purposes of a router is to confine LAN broadcast traffic to each local network or subnetwork.
A proxy ARP response is generated when the following occurs:
• Proxy ARP is enabled on a router port.
• An ARP request is received as a LAN broadcast (looking for the MAC-layer address of an IP host on another network segment).
• An entry exists in the IP Forwarding Table for the destination host’s network.
Enabling Proxy ARP on a router port allows IP hosts to dynamically obtain the MAC-layer address of other IP hosts attached to different networks or subnetworks by using broadcast ARP request packets. With Proxy ARP enabled, IP hosts are not required to maintain knowledge of specific subnetworks.
To enable Proxy ARP on a router port, complete the following steps:
1.
Use the arrow keys to highlight the Proxy ARP option.
2.
Use the ENTER key to toggle the entry to ENABLED.
CSX400 and CSX400-DC User’s Guide 159
General Configuration Using Local Management
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen, and then press ENTER. The message “SAVED OK” displays.
Configuring the Network Broadcast Type on a Port
IP Routing Services recognizes and accepts network broadcasts, IP packets with the host portion of the IP address as either all 1’s or all 0’s. Other networking devices only recognize all 0’s as a network broadcast.
To configure IP Routing Services to send network broadcasts addressed to all 0’s, complete the following steps:
1.
Use the arrow keys to highlight the Network Bcast option.
2.
Use the ENTER key to toggle the entry to ZEROS.
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
Enabling the RIP Routing Protocol on a Port
Routing Information Protocol (RIP) is a widely implemented routing protocol that is used extensively on IP internetworks. IP Routing Services uses the RIP routing protocol to send and gather information about the internetwork topology. This information is used to construct and maintain a database called RIP Route Table, which contains the addresses of the available routes to all the networks and hosts that RIP has learned.
Enabling the RIP routing protocol allows IP Routing Services to build and maintain a dynamic database of route information. The best routes learned by the RIP routing protocol are added to the
IP Forwarding Table to forward IP packets. The ability to switch the RIP routing protocol on and off on a port-by-port basis provides great flexibility. On the same device, some router ports can be running the RIP routing protocol while other router ports are not. If necessary, you can temporarily disable the RIP routing protocol on any port without affecting the rest of your configuration.
To enable RIP Routing, complete the following steps:
1.
From the IP Configuration screen, highlight IP RIP and then press ENTER.
The IP RIP Configuration screen, shown in
2.
Use the arrow keys to highlight the System Level RIP-1 option.
3.
Use the ENTER key to toggle the entry to ENABLED.
4.
Use the arrow keys to highlight the Port Level RIP-1 option.
160 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
5.
Use the ENTER key to toggle the entry to ENABLED.
6.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen, and then press ENTER. The message “SAVED OK” displays.
CSX400 Local Management
IP Address: xxx.xxx.xxx.xxx
Port: 1
IP RIP CONFIGURATION
Flash Image Version XX.XX.XX
System Level RIP-1:
Port Level RIP-1:
DISABLED
DISABLED
+PORTSAVE
Figure 67 IP RIP Configuration Screen
RETURN
CSX400 and CSX400-DC User’s Guide 161
General Configuration Using Local Management
IPX Configuration Screen
The IPX Configuration screen enables you to access the IPX General Config, IPX RIP, and IPX
SAP screens to configure the CSX400 for IPX Routing and enable RIP routing or Source
Advertisement Protocol (SAP) routing on the CSX400.
Access the IPX Configuration screen, shown in
Figure 68 , by using the arrow keys to highlight the
IPX menu item on the Router Setup and pressing ENTER. The IPX Configuration screen displays.
CSX400 Local Management Flash Image Version XX.XX.XX
IPX CONFIGURATION
IPX General Config
IPX SAP
IPX RIP
RETURN
Figure 68 IPX Configuration Screen
IPX Configuration Fields
The following list describes each of the IPX Configuration screen fields.
IPX General Config —
CSX400 for IP routing.
Use this field to access the IPX General Config screen and configure the
IPX SAP — Use this field to access the IPX SAP screen and enable Source Advertisement
Protocol (SAP) routing on the CSX400.
IPX RIP — Use this field to access the IPX RIP screen and enable Routing Information Protocol
(RIP) on the CSX400.
162 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
IPX General Configuration Screen
The IPX General Configuration screen allows you to configure the CSX400 for IPX routing.
Access the IPX General Configuration screen by using the arrow keys to highlight the IPX
General Config menu item and pressing ENTER. The IPX General Configuration screen shown in
displays.
CSX400 Local Management Flash Image Version XX.XX.XX
IPX General Configuration
Router Name: IPX
Version: XX.XX.XX
Status: Enabled UpTime: 0 days 0 hours 39 min
AdminStatusTime: 0 days 0 hours 39 min
System Level Setup
IPX Routing: ENABLED
Port Level Setup
Port: 1 Description: Ctron CSX400 EnetPort
MAC Address: 00-00-1D-22-46-B0
Oper Status: Enabled MTU: 1500
IPX Address: 0.0.0.0
Interf. Type: ethernet-csmacd
Framing: Novell
IPX Routing: DISABLED
IPX Forwarding: DISABLED
+PORTSAVE RETURN
Figure 69 IPX General Configuration Screen
IPX General Configuration Status Fields
The following list describes each of the IPX General Config status fields. The status fields are for informational purposes only and cannot be modified.
Router Name — Displays the type of routing used.
Status — Displays the status of IP Routing.
UpTime — Displays the amount of time elapsed since the last time the CSX400 was rebooted.
Version — The version number of the IP Routing used on the CSX400.
CSX400 and CSX400-DC User’s Guide 163
General Configuration Using Local Management
AdminStatusTime — the CSX400.
Displays the amount of time elapsed since an IP address was assigned to
Description — Describes the selected Port.
MAC Address — Displays the physical (MAC) address of the CSX400.
Interf. Type — Displays the type of interface used by the specified port.
Oper Status — Displays the operational status of the selected port.
IPX General Configuration Fields
This section provides a general overview of the procedures required to configure the CSX400. The following list describes each of the IPX General Config fields.
+PORT- — Use this field to select the routing port that you wish to configure.
Framing — Use this field to select the format of the Frame in which IPX packets are encapsulated for transmission.
MTU — Use this field to set the Maximum Transmission Unit (MTU).
IPX Routing — Use this field to enable IP Routing Services.
IPX Forwarding — Use this field to enable IP Forwarding.
IPX Address — Use this field to assign an IP Address to the port that you wish to configure.
Selecting a Port for Configuration
Routing Services allows you to choose the ports that you want to configure for IPX routing. To select a router port to configure for IPX routing, complete the following steps:
1.
Use the arrow keys to highlight the PORT option.
2.
Type in the number of the port that you want to configure for IPX routing, then press ENTER.
NOTE
You can type in the port number, or you can use the + PORT option at the bottom of the screen to scroll through the list of the ports on your device. To use the + PORT option, use the arrow keys to highlight the + (to go forward), or the (to go backward), and then press ENTER to scroll through the available ports in the direction you have selected. You can also use the + and - keys to scroll through the available ports.
164 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
If you type in an invalid port number the error message: “PORT NUMBER IS OUT OF RANGE” displays. Perform steps 1 and 2 again.
Entering the IPX Address
All IPX hosts must have an IPX Address for each network interface. These addresses identify each network connection.
To enter the IPX Address for a router port, complete the following steps:
1.
Use the arrow keys to highlight the IPX ADDRESS option.
2.
Type in the IPX Address in Dotted Decimal Notation (DDN) format and then press ENTER.
Selecting the Frame Type for a Port
On each port, Frame Type specifies the format of the frame in which IPX packets are encapsulated for transmission. The Frame Type options available for each router port are dependent on the type of media supported by that router port.
To select the Frame Type for a port, complete the following steps:
1.
Use the arrow keys to highlight the Framing option.
2.
Use the ENTER key to toggle the entry to the correct Frame Type for the port.
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
Setting the Maximum Transmission Unit (MTU)
The Maximum Transmission Unit specifies the maximum packet size for all IPX packets that are transmitted.
To select the MTU for a port, complete the following steps:
1.
Use the arrow keys to highlight the MTU option under Port Level Setup.
2.
ENTER an MTU value for the media used.
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
CSX400 and CSX400-DC User’s Guide 165
General Configuration Using Local Management
Enabling IPX Routing Services on a Port
The ability to switch IPX Routing Services on and off on a port-by-port basis provides great flexibility. On the same device, some ports can be routing IPX traffic while other ports are bridging it. As you are in transition from a bridged network to a routed network, this flexibility allows you to implement IPX routing and test your routing configuration on a port-by-port basis. If necessary, you can temporarily disable IPX routing on any port without losing your configuration, or you can temporarily switch from IPX routing back to bridging.
To enable IPX Routing Services on a router port, complete the following steps:
1.
Use the arrow keys to highlight the IPX Routing option under Port Level Setup.
2.
Use the ENTER key to toggle the entry to ENABLED.
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
Enabling IPX Forwarding on a Port
By default, IPX Forwarding is disabled on each router port. Your device cannot begin forwarding
IPX data packets on any router port until you enable IPX Forwarding on that port.
To enable IPX Forwarding on a router port, complete the following steps:
1.
Use the arrow keys to highlight the IPX Forwarding option.
2.
Use the ENTER key to toggle the entry to ENABLED.
3.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen and then press ENTER. The message “SAVED OK” displays.
166 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
IPX Routing over Frame Relay
An additional step is required when routing IPX over Frame Relay. This step requires that entries are created in the IPX Host Map. The IPX Host Map is a database of remote IPX hosts that are defined generally by the WAN Network number and MAC Address, and more specifically by the
Interface Number and Data Link Connection Identifier (DLCI). The IPX Host Map helps a routing decision by determining which circuit a packet should be forwarded to in a point to multi-point
Frame Relay connection.
Figure 70 shows how IPX Host Map entries are entered using the circuitmap command. The
circuitmap command is accessed from the
MIB Navigator Screen . Refer to
information on the circuitmap command.
MIBNav-> circuitmap -s IPX 2 00000172 00:00:1d:02:d1:7a 102
# Interface
# 2
Network
00000172
Node
00:00:1d:23:a1:5b
Circuit ID
102
Figure 70 Circuitmap Command circuitmap
The circuitmap command contains the following fields:
#Interface — interface.
An entry must be created for each remote Router connected via the Frame Relay
Network — The Network is the IPX Network number associated with the Frame Relay network.
Node — The Node is the MAC address of the remote router on the other end of the WAN link.
Circuit ID — The Circuit ID is the DLCI identifying the virtual circuit connection to the Telco.
CSX400 and CSX400-DC User’s Guide 167
General Configuration Using Local Management
Enabling the IPX SAP Routing Protocol on a Port
IPX Source Advertisement Protocol (SAP) is used by IPX to exchange information about Novell service providing nodes, such as file servers and print servers that are available. IPX SAP builds and maintains a database, the Service Advertisement Table, containing the addresses and routes to specific service providing nodes, and advertises this information over the network.
Each router running IPX SAP gathers this LAN based information from the locally connected network segments and adds it to its Service Advertisement Table. Each table contains the Novell
Network Number and type of services available on all Novell servers known to the IPX SAP. IPX routing services uses this information to provide internetworked NetWare clients with access to these services.
168 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
To enable SAP Routing, complete the following steps:
1.
From the IPX Configuration screen, highlight IPX SAP and then press ENTER.
The IPX SAP Configuration screen, shown in Figure 71 , displays.
2.
Use the arrow keys to highlight the Port option.
3.
Type in the number of the port that you wish to enable SAP routing, then press ENTER.
4.
Use the arrow keys to highlight the Port Level SAP option.
5.
Use the ENTER key to toggle the entry to ENABLED.
6.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen, and then press ENTER. The message “SAVED OK” displays.
CSX400 Local Management
IPX Address: xxx.xxx.xxx.xxx
Port: 1
IPX SAP CONFIGURATION
System Level SAP:
Port Level SAP:
Flash Image Version XX.XX.XX
DISABLED
DISABLED
+PORTSAVE
Figure 71 IPX SAP Configuration Screen
RETURN
CSX400 and CSX400-DC User’s Guide 169
General Configuration Using Local Management
Enabling RIP on a Port
IPX RIP (Routing Information Protocol) is a widely implemented routing protocol that is used extensively on IPX intermediations. IPX Routing Services uses the RIP to send and gather information about the internetwork topology. This information is used to construct and maintain a database, called the RIP Route Table, containing the addresses and available routes to all the networks and hosts that RIP has learned.
Enabling RIP allows IPX Routing Services to build and maintain a dynamic database of route information. The best routes learned by RIP are added to the IPX Forwarding Table to be used to forward IPX packets. The ability to switch RIP on and off on a port-by-port basis provides great flexibility. On the same device, some router ports can be running RIP while other router ports are not. If necessary, you can temporarily disable RIP on any port without affecting the rest of your configuration.
170 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
To enable RIP Routing, complete the following steps:
1.
From the IPX Configuration screen, highlight IPX RIP and then press ENTER.
The IPX RIP Configuration screen, shown in
2.
Use the arrow keys to highlight the Port option.
3.
Type in the number of the port that you wish to enable RIP routing and then press ENTER.
4.
Use the arrow keys to highlight the Port Level RIP option.
5.
Use the ENTER key to toggle the entry to ENABLED.
6.
Use the arrow keys to highlight the SAVE command field at the bottom of the screen, and then press ENTER. The message “SAVED OK” displays.
CSX400 Local Management
IPX Address: xxx.xxx.xxx.xxx
Port: 1
IPX RIP CONFIGURATION
Flash Image Version XX.XX.XX
System Level RIP:
Port Level RIP:
DISABLED
DISABLED
+PORTSAVE
Figure 72 IPX RIP Configuration Screen
RETURN
CSX400 and CSX400-DC User’s Guide 171
General Configuration Using Local Management
WAN Setup
NOTE
This section describes the HDSL WPIM. For all other WPIMs, refer to your specific
WPIM(s) Local Management Guide for information on this screen .
The WAN Setup menu item accesses two screens which allow you to configure the CSX400 for a
WAN Physical Interface Module (WPIM).
Access the WAN Physical Configuration screen, shown in Figure 73
, by using the arrow keys to highlight the WAN SETUP menu item and pressing ENTER. The WAN Physical Configuration screen displays.
Local Management
WAN PHYSICAL CONFIGURATION
Flash Image Version XX.XX.XX
WPIM 1
Type: HDSL
BRIM #: 1
Mode: [Primary]
Active: Yes
Ifaces: 003-026
WPIM 2
Type: T1
BRIM #: 2
Mode: [Primary]
Active: Yes
Ifaces: 027
WPIM 1 Line Configuration
HDSL Tx Clock Source: [Loop-Timing]
HDSL Timeslot Configuration: [Fractional]
SAVE [WPIM 1] WAN INT CONFIG
Figure 73 WAN Physical Configuration Screen
RETURN
172 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
WAN Physical Configuration Screen Fields
The following list describes the WAN Physical Configuration screen fields.
NOTE
The CSX400 supports a variety of WPIMs.
Figure 73 shows the WAN Physical
Configuration screen for the WPIM-HDSL and the WPIM-T1. To select the WPIM you wish to configure, use the arrow keys to highlight the [WPIM #] field at the bottom of the screen. Use the SPACEBAR to select the appropriate WPIM, then press ENTER.
WPIM # — Displays configuration information for the WPIMs that are installed.
Type — Displays the WPIM type.
BRIM # — Displays the BRIM slot in which the WPIM resides.
Mode — Displays the WPIM mode.
Active — Displays the status of the WPIM.
Ifaces — Displays the interfaces available to each WPIM.
WPIM-HDSL Configuration Fields
HDSL Tx Clock Source — Displays the HDSL Transmit Clock Source. The selections for this field toggle between Loop-Timing (Extracted Line Data) and Local-Timing (Internal Clock). The default setting for this field is Loop-Timing.
NOTE
The Loop-Timing selection in this Local Management screen corresponds to the Slave selection in the QuickSET HDSL WAN Configuration window; the Local-Timing selection corresponds to the Master selection.
HDSL Timeslot Configuration — Displays the timeslot configuration for the WPIM. The selections for this field toggle between Full and Fractional. The default setting for this field is Full.
Full uses all 24 timeslots and Fractional uses the first 12 timeslots.
CSX400 and CSX400-DC User’s Guide 173
General Configuration Using Local Management
WAN Interface Configuration Screen
To access the WAN Interface Configuration screen shown in Figure 74
, use the arrow keys to highlight the WAN INT CONFIG selection at the bottom of the WAN Physical Configuration screen, then press ENTER.
Local Management
WAN INTERFACE CONFIGURATION
Flash Image Version: xx.xx.xx
Interface Number: [002]
Max Xmit Unit: 0
Line Coding: [NONE]
Active Protocol: [NONE]
PT# IF# LID STATE
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
001 Enet UP
PT# IF# LID STATE
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
032
SAVE
PORTS:
[xx-xxx] RETURN
1484_04
Figure 74 WAN Interface Configuration Screen
WAN Interface Configuration Screen Fields
This section describes the WAN Interface Configuration screen fields.
Interface Number — Displays the active Interface Number. Use this field to configure the
Interface Numbers assigned on the WAN Physical Configuration screen.
Max Xmit Unit — User-configured field that displays the maximum packet size that can be transmitted on the selected Interface. The default values are 8191 for PPP and 4095 for Frame
Relay.
Line Coding — Displays the Line Coding for Timeslots associated with this interface. This field displays JBZS, INV-HDLC, or None. The default setting is None.
174 CSX400 and CSX400-DC User’s Guide
General Configuration Using Local Management
Active Protocol — Displays the active OSI Layer protocol. This field displays None, FR (Frame
Relay), or PPP (Point-to-Point). The default setting is None.
If you select PPP, the following field appears:
PPP Type : This field displays BNCP or LEX.
Circuit State: Toggles between Active, Inactive and Invalid.
PT# — Displays the application ports (bridge ports) available from the host platform to the WAN.
If the active protocol is PPP, Local Management assigns only one application port per interface number (IF#). If the active protocol is Frame Relay, Local Management assigns the available WAN bridge ports from the host platform, one per DLCI.
You can assign WAN application ports to the 31 interfaces for the PPP configuration that suits your needs. In a Frame Relay configuration, you can assign all WAN application ports to one interface.
In this example, the remaining 30 interfaces would not have WAN application ports available.
The quantity of application ports for a Frame Relay network is determined by the quantity of
DLCIs (Data Link Connection Identifiers) assigned to that Interface. This is determined either manually or by the LMP (Link Management Protocol).
IF# — Displays the Interface that is associated with the application port.
LID — Displays the Link Identifier. If the active protocol is Frame Relay, the Data Link
Connection Identifier is displayed. If the active protocol for this interface is PPP, then PPP displays in this field.
STATE — Displays the status of the application port. If the active protocol is Frame Relay, this field displays the status as Active, Inactive, or Disabled (for No LMI). If the active protocol is PPP, this field displays UP (for active) or DOWN (for inactive).
PORTS: [xx-xxx] — Toggles through the ports.
CSX400 and CSX400-DC User’s Guide 175
General Configuration Using Local Management
176 CSX400 and CSX400-DC User’s Guide
9
MIB Navigator
This chapter explains how to use the MIB Navigator utility. The MIB Navigator allows access to a command set from which you can configure and manage the CSX400.
Chapter Organization
The following list summarizes the organization of this chapter:
– describes the MIB Navigator screen and explains how to access it.
MIB Navigator Command Set Overview – describes the types of commands available to the
MIB Navigator.
– explains the commands used to navigate through the MIB Navigator.
Other Commands – explains other commands that allow you to access and manage network
devices connected to the device running the MIB Navigator.
– explains the special commands that allow you to exit from the MIB
Navigator.
CSX400 and CSX400-DC User’s Guide 177
MIB Navigator
MIB Navigator Screen
Access the MIB Navigator screen from the Main Menu screen using Local Management (refer to
the Accessing Local Management
section in Chapter 8 ). Using the arrow keys, highlight the
MIB NAVIGATOR option, then press ENTER. The MIB Navigator screen shown in
displays.
Welcome to MIB Navigator
MIBNav-> help
Navigation Commands: branch cd dir
Is pwd tree get mib2 set whoami
Other Commands: arp dhcp ping secondIP snmpnext bridge imux ppp show snmpset ctron grep next su help circuitmap nat reset snmpbranch snmptree defroute netstat route snmpget traceroute
SPECIAL: done, quit, or exit - Exit from the MIB Navigator.
mib2 - Change directory to MIB II (/1/3/6/1/2/1).
ctron - Change directory to Cabletron MIB (/1/3/6/1/4/1/52).
For help with a specific command, type 'help <command>'.
MIBNav->
Figure 75 The MIB Navigator Screen
090829
Managing Device MIBs
The MIB Navigator lets you manage objects in the CSX400 Management Information Bases
(MIBs). MIBs are databases of objects used for managing the device and determining the CSX400 configuration. The commands within the MIB Navigator allow you to view and modify a device’s objects.
178 CSX400 and CSX400-DC User’s Guide
MIB Navigator
The MIB Navigator views the MIB tree hierarchy as a directory.
hierarchy. Each layer is numerically encoded, so that every branch group and leaf object in the
MIB is identified by a corresponding number, known as an Object Identifier (OID). This allows the
MIB Navigator to navigate through the MIB and access the manageable leaf objects.
Root 1
Group 1.1
Group 1.2
Group 1.3
Object 1.1.1
Object 1.1.2
Object 1.2.1
Object 1.2.2
Object 1.3.1
Object 1.3.2
1574-27
Figure 76 Hierarchical MIB Tree Structure
Often an ASCII name is assigned to the OID of a leaf object, making it more readable. To identify the value for the object “ipForwarding” you use the OID (/1/3/6/1/2/1/4/1), or its ASCII name (/ iso/org/dod/internet/mgmt/mib-2/ip/ipForwarding).
MIB Navigator Command Set Overview
Use the help command for an on-line description of each MIB Navigator command. For example MIB Nav-> help branch provides help information for the branch command.
TIP
The MIB Navigator command set provides the following commands:
Navigation Commands — Navigation commands allow you to access and manage the MIB for the device running the MIB Navigator. Some of these commands also provide user community-string information. The commands are as follows: branch dir
Is pwd tree cd get mib2 set whoami ctron grep next su help
CSX400 and CSX400-DC User’s Guide 179
MIB Navigator
Other Commands — Other commands allow you to access and manage network devices connected to the device running the MIB Navigator. The commands are as follows: arp dhcp ping secondIP snmpnext bridge imux ppp show snmpset circuitmap nat reset snmpbranch snmptree defroute netstat route snmpget traceroute
Special Commands — commands are as follows:
Special Commands allow you to exit from the MIB Navigator. The done quit exit
Conventions for MIB Navigator Commands
This manual uses the following conventions for denoting commands:
• Information keyed by the user is shown in this helvetica font.
• Command arguments are indicated by two types of brackets:
required arguments are enclosed by [ ].
optional arguments are enclosed by < >.
MIB Navigator command conventions are as follows:
• To abort the output or interrupt a process the escape character is ^C (where ^ indicates the
Control key).
• A slash (/) preceding an OID issues that command from the root directory regardless of where you are in the MIB. If no slash precedes the OID the command issues from your current MIB location.
• Dot notation (1.1.1.1) is equivalent to slash notation (1/1/1/1). Use slash notation with the navigational commands, and the dot notation with the built-in commands that are using SNMP to access and manage network devices.
180 CSX400 and CSX400-DC User’s Guide
MIB Navigator
MIB Navigation Commands are listed in the format shown below: command:
Syntax:
Description:
Options:
Example:
This entry provides the format that the MIB Navigator command requires. It indicates where arguments, if any, must be specified.
This entry briefly describes the command and its uses.
This entry lists any additional fields which may be added to the command and their format.
This entry shows an example of the command.
Navigation Commands
The following MIB Navigation commands allow you to move from MIB object to MIB object within the MIB tree. branch:
Syntax:
Description:
Options:
Example: branch [path]
The branch command displays all of the leaves in the MIB tree below a specified path. The information displayed includes the pathname, the object ASCII name, the type of object (i.e., integer, counter, time tick, etc.), and the current value of each leaf object.
Not Applicable
MIBNav-> branch
# /1/3/6/1/2/1/7/1
# /1/3/6/1/2/1/7/2
# /1/3/6/1/2/1/7/3 udpInDatagrams udpNoPorts udpInErrors
COUNTER
COUNTER
COUNTER
38216
0
0
051456
CSX400 and CSX400-DC User’s Guide 181
MIB Navigator cd:
Syntax:
Description:
Options:
Example: cd [path] or cd <option>
The cd command allows you to change directories within a MIB subtree
(branch). The path specified must be valid, or the MIB Navigator will not perform the cd operation.
.. Moves you one subtree above the current one.
/ Moves you to the root.
ctron:
Syntax:
Description:
Options:
Example:
MIBNav-> cd iso/org/dod/internet/mgmt
051457 ctron
The ctron command allows you to change directories to the Cabletron
MIB (1.3.6.1.4.1.52) without keying in the entire path.
Not Applicable
MIBNav-> ctron
051458
182 CSX400 and CSX400-DC User’s Guide
help:
Syntax:
Description:
Options:
Example: mib2:
Syntax:
Description:
Options:
Example:
MIB Navigator help <command>
The help command provides general help on how to use the MIB
Navigator or how to use a particular MIB Navigator command.
A particular MIB Navigator command.
MIBNav-> help su
Command: su
Format: su <Community Name>
Allows user to change his/her community name, in order to allow different access to the MIB.
051459 mib2
The mib2 command allows you to move directly to the MIB II subtree
(1.3.6.1.2.1) without entering the entire path.
Not Applicable
MIBNav-> mib2
051460
CSX400 and CSX400-DC User’s Guide 183
MIB Navigator next:
Syntax:
Description:
Options:
Example: next [path]
The next command enables you to determine the next leaf in the specified path within the managed device’s MIB.
Not Applicable pwd:
Syntax:
Description:
Options:
Example:
MIBNav-> next /1/3/6/1/2/1
#/1/3/6/1/2/1/1/1 sysDescr String CtronRev.X.XX.XX
051461 pwd
The pwd command displays the full pathname for the directory in which you are currently working. The directory is displayed in ASCII format.
Not Applicable
MIBNav-> pwd
# /iso/org/dod/internet/mgmt/mib-2
051462
184 CSX400 and CSX400-DC User’s Guide
set:
Syntax:
Description:
Options:
Example:
MIB Navigator set <OID> <value>
The set command enables you to set the value of a managed object. This command is valid only for leaf entries in the current MIB tree, or for managed objects in the MIB.
If the leaf specified does not exist for the given path, MIB Navigator asks for a value. The following lists possible value types:
( i )nteger - number
( c )ounter - number
( g )auge - number
( t )ime ticks - number o( p )aque - “value” (with quotation marks)
( s )tring - “value” (with quotation marks)
( o )id - OID number with dotted punctuation
( a )ddress - IP address in DDN format
( m )ac - MAC address in hexadecimal format
( n )ull - no type
Not Applicable
MIBNav-> set /1/3/6/1/4/1/52/1/6/4/7 122.1.1.1
Type: (i)nteger (a)ddress (c)ounter (g)auge (o)id:
051463
CSX400 and CSX400-DC User’s Guide 185
MIB Navigator su:
Syntax:
Description:
Options:
Example: su [community name]
The su command enables you to change your community name to allow for different access to the MIB. The community name that you enter allows you either read-only, read-write, or super-user access to that device’s MIBs, depending on the level of security access assigned the password through the SNMP Community Names screen. Refer to the
for more information about community names.
Not Applicable tree:
Syntax:
Description:
Options:
Example:
MIBNav-> su public
051464 tree
The tree command provides a display of the entire MIB for the device.
Leaves and associated values are displayed in columns.
Not Applicable
MIBNav-> tree
# /1/3/6/1/2/1/1/1
# /1/3/6/1/2/1/1/2
# /1/3/6/1/2/1/1/3
# /1/3/6/1/2/1/1/4 sysDescr sysObjectId sysUpTime sysContact
STRING
OBJECT ID
TIME TICKS
STRING
EMRev X.X.X.X
1.3.6.1.4.1.52
8098654
AlZwie/MIS
051465
186 CSX400 and CSX400-DC User’s Guide
MIB Navigator whoami:
Syntax:
Description:
Options:
Example: whoami
The whoami command displays your community string and access privileges to the MIB. When using the whoami command, one of these three access levels displays: read-only, read-write, and super-user.
Not Applicable
MIBNav-> whoami
# Community Name
# Access Level
: super
: SuperUser grep <option> string
Allows a user to search the MIB tree for a specific character string. All leafs in the MIB tree are searched.
-m : Displays on the terminal one screen at a time.
-i : Ignores case when searching for string.
051466 grep:
Syntax:
Description:
Options:
Example:
MIBNav-> grep -i cabletron # /1/3/6/1/2/1/1/1 sysDescr String Cabletron MMAC-Plus Revision 01_01_01
051457
CSX400 and CSX400-DC User’s Guide 187
MIB Navigator dir:
Syntax:
Description:
Options:
Example: get:
Syntax:
Description:
Options:
Example: dir [- 1pdm] [PATH]
Lists the contents of the directory sub-tree specified. If no
[directory-path] is specified, the contents of the current directory are displayed. The display options are:
-1 : Displays the OID value along with the ASCII name of the leaf object.
-p : Lists all the entries along with the path name of the leaf object.
-d : Lists only the directory entries in the tree.
-m : Displays one screen at a time.
Not Applicable
MIBNav-> cd/iso/org/dod/internet dir mgmt private dir - lp
/1/3/6/1/4/iso/org/dod/internet/private dir get <PATH>
Returns the value of a managed object. This is only valid for “leaf” entries in the MIB tree (or managed objects in the MIB).
Not Applicable
MIBNav-> get /1/3/6/1/2/1/1/1
#System name description get
188 CSX400 and CSX400-DC User’s Guide
ls:
Syntax:
Description:
Options:
Example:
MIB Navigator ls [-1pdm] [PATH]
Lists the contents of the directory sub-tree specified. If no
[directory-path is specified, the contents of the current directory are displayed. The display options are:
-1: Displays the OID value along with the ASCII name of the leaf object.
-p: Lists all the entries along with the path name of the leaf object.
-d: Lists only the directory entries in the tree.
-m: Displays one screen at a time.
Not Applicable
MIBNav-> cd/iso/org/dod/internet ls - lp mgmt private ls - lp
/1/3/6/1/2 /iso/org/dod/internet/mgmt
/1/3/6/1/4 /iso/org/dod/internet/private ls
CSX400 and CSX400-DC User’s Guide 189
MIB Navigator
Other Commands
The Other commands listed in this section activate functions on the LM managed device or devices being accessed through MIB Navigation.
arp:
Syntax:
Description:
Options: arp <options>
The arp command provides access to the ARP (Address Resolution
Protocol) cache, enabling you to view cache data, delete entries, or add a static route. Super-user access is required to delete an entry or add a static route.
Each ARP cache entry lists: the network interface that the device is connected to, the device’s network address or IP address, the device’s
physical address or MAC address, and the media type of connection to the device. Media types are displayed as numbers, which stand for the following states:
1 - Other
2 - Invalid entry (cannot ping device, timed out, etc.)
3 - Dynamic route entry
4 - Static route entry (not subject to change)
-a Views cache data
-d Deletes an IP address entry.
Requires additional arguments: <Interface Number> <IP address>
-s Adds a static entry.
Requires additional arguments: <Interface Number> <IP address>
<MAC address>
190 CSX400 and CSX400-DC User’s Guide
Example: defroute:
Syntax:
Description:
Options:
Example: dhcp:
Syntax:
Description:
Options:
MIB Navigator
MIBNav-> arp -a
# Interface
# (SonicInt)
# (SonicInt)
# (SonicInt)
# (SonicInt)
Network Address
122.144.40.111
122.144.48.109
122.144.52.68
122.144.21.43
Physical Address
00.00.0e.12.3c.04
00.00.0e.f3.3d.14
00.00.0e.12.3c.04
00.00.0e.03.1d.3c
Media Type
3(dynamic)
3(dynamic)
3(dynamic)
3(dynamic)
MIBNav-> arp -d 1 122.144.52.68
MIBNav-> arp -s 1 22.44.2.3 00:00:0e:03:1d:3c
051467 defroute [interface number] [IP address]
The defroute command allows you to set the default IP route to a managed device through the specified interface.
Not Applicable
MIBNav-> defroute 2 147.152.42.32
051469 dhcp <options>
The dhcp command provides a status of the Dynamic Host Configuration
Protocol feature. Allows the user to enable/disable DHCP globally and by interface, and to configure interfaces with server parameters.
dhcp (with no options) Displays DHCP status information.
dhcp enable/disable. Enables or disables the DHCP feature globally.
dhcp <IFNUM> enable disable Enables or disables the DHCP feature by interface.
CSX400 and CSX400-DC User’s Guide 191
MIB Navigator dhcp reclaim <IPADDRESS> Reclaims an IP address so another client can use it.
dhcp <IFNUM> <GATEWAY> <DNSADDRESS>
<WINSADDRESS> <DOMAINNAME> The IFNUM is the Ethernet port number. The four configuration parameters can be passed to the hosts (clients). These are the IP address of their default gateway, the IP address of their domain name server, the IP address of their WINS server, and their domain name.
dhcp <IFNUM> <NETADDRESS> <NETMASK>
<LOWADDRESS> <HIGHADDRESS> <LEASE> Allows the user to specify the lease period for the hosts (clients), from one hour to many years. Selectable on a per port basis only.
<IFNUM> The Ethernet port number .
<NETADDRESS> The IP network on which the hosts will reside .
<NETMASK> The subnet mask for the hosts .
<LOWADDRESS> The lowest numerical value of the IP range to be allocated .
<HIGHADDRESS> The highest numerical value of the IP range .
Example:
MIBNav->dhcp
DHCP Server Summary:
Admin: Enabled Oper: Enabled Server Time: 458400
Discovers: 0, Offers: 0, Requests: 2, Errors: 0
Declines: 0, Releases: 0, Acks: 2, Naks: 0, Other Servers: 0
DHCP Interface Configuration:
IF Admin Oper ServerIP Active Free
1 Enabled Enabled 192.168.254.254 2 250
IF Net Address Net Mask Low Address High Address Lease
1 192.168.254.0 255.255.255.0 192.168.254.2 192.168.254.253 2880
IF Default Gateway DNS Address WINS Address Domain Name
1 192.168.254.254 134.141.72.219 134.141.70.34 ctron.com
DHCP Client Status:
# IF MAC Address Net Address Time Left Name
1 1 00:a0:c9:39:5e:40 192.168.254.2 22980 crotty
2 1 00:00:1d:16:71:99 192.168.254.3 22980 slowhand dhcp
192 CSX400 and CSX400-DC User’s Guide
nat:
Syntax:
Description:
Options:
Example:
MIB Navigator nat <options>
The nat command provides status relating to Network Address
Translation. Allows the user to assign a private network to an interface, to define an interface to access the internet through, and to create a public
IP address to be used on the internet. Allows the user to assign a host on the private network as a “proxy server” accessible from the internet.
nat (with no options) displays status information nat enable/disable Enables or disables the NAT feature.
nat config <PRIVATEIFNUM> <PUBLICIFNUM> Selects the local and public interfaces .
nat proxy add <ENTRY_NUMBER> <PRIVATEIP>
<PUBLICPORT> <LOCALPORT> <PROTOCOL> Adds a proxy server nat proxy delete <ENTRY_NUMBER> Deletes a proxy server
MIBNav->nat
NAT Status:
Admin: Enabled Oper: Enabled Local Interface: 1 Internet Interface: 2
Local IP Local mask Internet IP Internet mask
192.168.254.254 255.255.255.0 134.141.17.165 255.255.0.0
Connections- TCP: 0, UDP: 0, ICMP: 0
Local to inet- pkts: 116, bytes: 10814
Inet to local- pkts: 91, bytes: 39812
Errors: cksum: 0, retries: 1, bad packets: 0
Total IP pkts: 3917, Reserved addresses: 2919
Server List:
Connections: #
# Number of valid entries: 0 nat
CSX400 and CSX400-DC User’s Guide 193
MIB Navigator netstat:
Syntax:
Description:
Options:
Example: netstat <option>
The netstat command provides a display of general network statistics for the managed device. The netstat command must be used with one of the two display options.
-i Display status and capability information for each interface
-r Display routing information for each interface ping:
Syntax:
Description:
Options:
Example:
MIBNav-> netstat -i
Interface + Description
# 1 (ethernet -csmacd)
# 2 (ethernet - csmacd)
# 3 (ethernet - csmacd)
# 4 (ethernet - csmacd)
MTU
1514
1514
1514
1514
MIBNav-> netstat -r
Destination
# Default Route
# 134.141.0.0
# 134.141.0.0
Next-hop
DirectConnection
DirectConnection
DirectConnection
Speed Admin
10000000
10000000
10000000
10000000 up up up up
Oper MAC Addr up up up up
0x00 0x00 0x1d 0x07 0x50 0x0e
0x00 0x00 0x1d 0x07 0x50 0x0f
0x00 0x00 0x1d 0x07 0x50 0x10
0x00 0x00 0x1d 0x07 0x50 0x11
Interface
1
2
3
051470 ping [IP address]
The ping command generates an outbound ping request to check the status (alive/not alive) of a device at a specified IP address.
Not Applicable
MIBNav-> ping 122.144.40.10
122.144.40.10 is alive
051471
194 CSX400 and CSX400-DC User’s Guide
MIB Navigator snmpbranch:
Syntax:
Description:
Options:
Example: snmpget:
Syntax:
Description:
Options:
Example: snmpbranch [IP address] [community name] [OID]
The snmpbranch command enables you to query another SNMP device.
The command provides a display of objects that match the specified
OID. If no match is made, no object is displayed.
Not Applicable
MIBNav-> snmpbranch 2.4.8.1 public 1.3.6.2.1.1
# /1/3/6/1/2/1/1/1
# /1/3/6/1/2/1/1/2
# /1/3/6/1/2/1/1/3
# /1/3/6/1/2/1/1/4 sysDescr sysObjectId sysUpTime sysContact
STRING
OBJECT ID
TIME TICKS
STRING
EMRev X.X.X.X
1.3.6.1.4.1.52
8098654
AlZwie/MIS
051473 snmpget [IP address] [community name] [OID]
The snmpget command enables you to query another SNMP device to obtain a value for a specified object. This command requires the appropriate community string and object id.
Not Applicable
MIBNav-> snmpget 22.44.61.22 public 1.3.6.1.2.1.1.1.0
# Cabletron EMME Revision X.XX.XX
051474
CSX400 and CSX400-DC User’s Guide 195
MIB Navigator snmpset:
Syntax:
Description:
Options:
Example: snmpset [IP address] [community name]
The snmpset command enables you to set the value of an object in other
SNMP devices. This command requires the appropriate community string and OID.
When defining a new leaf set, MIB Navigator asks for a value. The following lists possible value types:
( i )nteger - number
( c )ounter - number
( g )auge - number
( t )ime ticks - number o( p )aque - “value” (with quotation marks)
( s )tring - “value” (with quotation marks)
( o )id - OID number with dotted punctuation
( a )ddress - IP address in DDN format
( m )ac - MAC address in hexadecimal format
( n )ull - no type
Not Applicable
MIBNav-> snmpset 122.44.1.2 public
1.3.6.1.2.1.1.4.0 "Cyrus/MIS"
051475
196 CSX400 and CSX400-DC User’s Guide
snmptree:
Syntax:
Description:
Options:
Example: traceroute:
Syntax:
Description:
Options:
Example:
MIB Navigator snmptree [IP address] [community name]
The snmptree command provides a display of all objects in the device and their corresponding values.
Not Applicable
MIBNav-> snmptree 122.144.89.10 public
# /1/3/6/1/2/1/1/1
# /1/3/6/1/2/1/1/2
# /1/3/6/1/2/1/1/3
# /1/3/6/1/2/1/1/4 sysDescr sysObjectId sysUpTime sysContact
STRING
OBJECT ID
TIME TICKS
STRING
EMRev X.X.X.X
1.3.6.1.4.1.52
8098654
AlZwie/MIS
051476 traceroute [IP address]
The traceroute command generates a TRACEROUTE request to a specified IP address and provides a display of all next-hop routers in the path to the device. If the device is not reached, the command displays all next-hop routers to the point of failure.
Not Applicable
MIBNav-> traceroute 122.144.11.52
# next-hop[1] 122.144.61.45
# next-hop[2] 122.144.8.113
051477
CSX400 and CSX400-DC User’s Guide 197
MIB Navigator bridge:
Syntax:
Description:
Options:
Example: bridge <ENABLE/DISABLE> <IFNUM/ALL>
Allows management of bridging upon one or more interfaces of the device. Bridging may be enabled or disabled at your request, either one at a time or all at once. Specifying a single interface number affects the bridging status of that interface, while specifying ALL affects every interface of the device.
<ENABLE/DISABLE> Enables or disables bridging.
<IFNUM/ALL> Allows you to specify an interface number.
MIBNav-> bridge disable all bridge enable 1 bridge disable 1 bridge
198 CSX400 and CSX400-DC User’s Guide
circuitmap:
Syntax:
Description:
Options:
Example: ppp:
Syntax:
Description:
Options:
MIB Navigator circuitmap -a <PROTOCOL> circuitmap -f <PROTOCOL> circuitmap -d <PROTOCOL> <INTERFACENUM>
<NETADDRESS> <MACADDRESS> circuitmap -s <PROTOCOL> <INTERFACENUM>
<NETADDRESS> <MACADDRESS> <CIRCUIT>
Allows the user to view and/or modify a Protocol’s Circuit Map (i.e., address-to-circuit) table for the device. The -a option shows the user the current Host Map information for the device. The -d option allows the user to delete an entry from the table. The -s option allows the user to insert a static entry into the table. The -f option allows the user to flush the table. The device must be initialized after changing the Circuit Map.
Not Applicable
MIBNav-> circuitmap -s IPX 2 00000172 00:00:1d:02:d1:7a 102
MIBNav-> circuitmap -a
# Interface
# 2
# 2
Network
5A4C212B
00000172
Node
00:00:1d:23:a1:5b
00:00:1d:23:a1:5b
Circuit ID
203
102 circuitmap ppp
Provides additional status relating to PPP and its Network Control
Protocols.
Not Applicable
CSX400 and CSX400-DC User’s Guide 199
MIB Navigator reset:
Syntax:
Description:
Options: route:
Syntax:
Description: secondIP:
Syntax:
Description:
Options: reset
The reset command allows you to perform a soft reset of the device. The user is queried to confirm the reset command to insure against unwanted resets.
Note: The MIB Navigator’s connection to the device is terminated upon execution of this command.
Not Applicable route add <IPADDRESS> <IPADDRESS> <INTERFACENUM> route add <IPADDRESS> <IPADDRESS> <INTERFACENUM>
<METRIC> route delete <IPADDRESS> <IPADDRESS> <INTERFACENUM>
Allows you to add or delete static entries in the IP Forwarding Table for the device. The first address is the destination. The second address is the next hop for the given interface. The metric value is optional. If included, it is used to set the value of ipForwardingMetric1. When RIP is used, the metric specifies the distance in hops to the destination.
secondIP add <IPADDRESS> <INTERFACENUM> secondIP delete <IPADDRESS> <INTERFACENUM>
Allows you to add or delete secondary IP addresses on the interface.
Not Applicable
200 CSX400 and CSX400-DC User’s Guide
show:
Syntax:
Description:
Example: snmpnext:
Syntax:
Description:
Options:
Example:
MIB Navigator show <PROTOCOL> [TABLE]
The show command displays information concerning various components of the device. Protocols currently supported are IP and IPX.
Components of those protocols that are currently supported are ARP caches, route tables, FIB tables, server tables, and interface tables. The number of valid entries in the table is outputted at the end of the table display.
MIBNav-> show IP ARP
----------------------------------------------------------------------------------------------------------------
# Interface MediaType Physical Address NetworkAddress
# 4
# 4
(dynamic)
(dynamic)
00:00:1d:04:40:5d
08:00:20:0e:d8:31
203
102 show snmpnext [IPADDRESS] [COMMUNITY-STRING] [OBJECT-ID]
The snmpnext command allows the user to query another device using
SNMP. The next leaf of an object identifier can be retrieved from that device by supplying an appropriate community string and the values of the object identifier.
Not Applicable
MIBNav-> snmpnext 132.111.22.33 public 1.3.6.1.2.1.1.2
#1.3.6.1.2.1.1.1.3 sysUpTime Time Ticks 5490075 snmpnext
CSX400 and CSX400-DC User’s Guide 201
MIB Navigator imux:
Syntax:
Description:
Options: imux <options>
This function lets you balance your LAN traffic between two T1 WAN ports and is used with Point to Point Protocol (PPP). When you select
Inverse Multiplexing via QuickSET, bridging, IP routing, and IPX routing functions are all disabled. The WAN device at the other end of the WAN link(s) must be a Cabletron Systems device, capable of receiving the balanced WAN traffic. The imux command with no options displays the status information.
-ea enables the Inverse Multiplexer Application.
-da disables the Inverse Multiplexer Application.
-eg <GROUPID> enables the Inverse Multiplexer group designated by
<GROUPID>.
-dg <GROUPID> disables the Inverse Multiplexer group designated by
<GROUPID>.
-ac <GROUPID> <INTERFACENUM> Adds the WAN channel designated by <INTERFACENUM> to the Inverse Multiplexer group designated by <GROUPID>.
-dc <GROUPID> <INTERFACENUM> Deletes the WAN channel designated by <INTERFACENUM> from the Inverse Multiplexer group designated by <GROUPID>.
<GROUPID> A unique value identifying an element in a sequence of groups which belong to the WAN Inverse Multiplexer Application.
<INTERFACENUM> The MIB II ifIndex value used to represent a
WAN channel that has an appropriate datalink protocol associated with it.
Example:
MIBNav-> imux
WAN Inverse Multiplexer Status:
WAN Available BW Xmit Byte Count
Group ID Channel ID Physical Number (Kbits/sec) (bytes)
------------------------------------------------------------------------------------------------------------------------------------
1 1 1 1536000 291483387
1 2 2 1536000 292249652
Number of WAN Inverse Multiplexer Groups currenly programmed: 1
Number of WAN Inverse Multiplexer Channels currenly programmed: 2 imux
202 CSX400 and CSX400-DC User’s Guide
MIB Navigator
Special Commands
done, quit, exit:
Syntax:
Description:
Options:
Example: done
These commands enable you to exit from the MIB Navigator and return to the Main Menu screen.
Not Applicable
MIBNav-> done
Connection closed
051472
CSX400 and CSX400-DC User’s Guide 203
MIB Navigator
204 CSX400 and CSX400-DC User’s Guide
10
Troubleshooting
Use this chapter in conjunction with the LANVIEW status monitoring and diagnostic LEDs on the
CSX400 to diagnose power failures, collisions, cable faults and link problems.
Figure 77 shows the front panel LEDs. Table 24 ,
,
Table 27 , and Table 28 describe LED states.
If you are having difficulty installing and configuring the CSX400, perform the following steps:
• Review the CSX400 QuickSTART Guide to insure proper installation.
• Check that all cables and connectors have been attached properly.
• Verify that power has been applied to the CSX400.
Power
CPU
Receive
Transmit
Collision
Transmit
Receive
Link
Figure 77 CSX400 Front Panel LED
LED
Power (PWR)
Processor (CPU)
Table 24 CSX400 Hardware LED States
Color State
OFF
GREEN
OFF
RED
Power off
Power on
Power off
Fault condition detected
GREEN (blinking) NORMAL
Status 1
Status 2
Test
CSX400 and CSX400-DC User’s Guide 205
Troubleshooting
LED
Receive (RCV)
Collision (CLN)
Link (LNK)
Table 25 CSX400 LAN LED States
Color State
OFF Port Enabled, No Activity
AMBER (flashing) Receiving traffic
OFF
RED
NORMAL
Collision
OFF
GREEN
Power Off or Failure
NORMAL, link exists
LED
Transmit (XMT)
Receive (RCV)
Link (LNK)
Test
Table 26 CSX400 WAN LED States
Color State
OFF Not transmitting traffic
GREEN (flashing) Transmitting traffic
OFF Not receiving traffic
AMBER (flashing) Receiving traffic
OFF
GREEN
AMBER
RED
OFF
AMBER (flashing)
WPIM not configured
NORMAL, link exists
Link exists in STANDBY
WPIM configured, link does not exist
NORMAL
Power-up diagnostics
Loopback testing
206 CSX400 and CSX400-DC User’s Guide
Troubleshooting
WPIM
T1, DI, and E1
DDS
SYNC
HDSL
S/T
Table 27 CSX400 WAN LED States for STS 1
Color State
OFF
RED
OFF
AMBER
OFF
GREEN
OFF
RED
GREEN
OFF
GREEN
Normal or port disabled
Red alarm
Normal or port disabled
Out of service (OOS)
Inactive or disabled
Request to send (RTS)
Port disabled or in loopback mode
Loop 1 not synchronized, in T1 and
Fractional T1 mode
Loop 1 synchronized
B1 not active or port disabled
B1 active
WPIM
T1, D1, and E1
DDS
SYNC
HDSL
S/T
Table 28 CSX400 WAN LED States for STS 2
Color State
OFF
AMBER
OFF
OFF
GREEN
OFF
RED
GREEN
OFF
GREEN
Normal or port disabled
Yellow alarm
Normal or port disabled
Inactive or disabled
Clear to send (CTS)
Port disabled, in Loopback mode, or
Fractional T1 mode
Loop 2 not synchronized (T1 mode only)
Loop 2 synchronized (T1 mode only)
B2 not active or port disabled
B2 active
CSX400 and CSX400-DC User’s Guide 207
Troubleshooting
Troubleshooting CSX400 Hardware
Power (PWR) LED is OFF
• Check that the power connection is firmly attached to the back panel of the CSX400, and the other end to an active power source.
Processor (CPU) LED is OFF
If the CPU stays OFF for an extended amount of time, and the power (PWR) light remains on, the
CPU is in an unknown state.
•
Contact Cabletron Systems Global Call Center for technical support (refer to Getting Help
in
).
Processor (CPU) LED is RED
The processor has detected a fault condition.
• Contact Cabletron Systems Technical Support (refer to
Troubleshooting the LAN
Collision (CLN) LED is RED
Collisions are normal in an Ethernet network, however, increased collisions may indicate that the network is out of specification (the propagation delay between two nodes on the network exceeds
25.6
µ s).
Link (LNK) LED is OFF
• Check that the CSX400 and the device at the other end of the segment are powered up.
• Verify that the RJ45 connectors on the twisted pair segment have the correct pinouts.
• Check the cable for continuity.
• Check that the cable meets the specifications for dB loss.
208 CSX400 and CSX400-DC User’s Guide
Troubleshooting
Troubleshooting the WAN
Link (LNK) LED is OFF
The WAN interface is not configured for operation.
• Use QuickSET or Local Management to make sure that the WAN interface is configured correctly.
Link (LNK) LED is RED
The WAN interface is configured, but there is no signal indicating that a valid connection is present on the WAN interface.
• Check that the CSX400 and the device at the other end of the segment are powered up.
• Use QuickSET or Local Management to make sure that both WAN interfaces, local and remote, are configured correctly.
• Check to ensure that the correct cable is being used.
• Check to ensure that the cable has continuity and is fully installed.
• Check with the WAN Service Provider to ensure that the circuit has been configured by them and is active.
Link (LNK) LED is AMBER
The port is in Standby mode.
• Check with the Network Administrator to see if management placed the port in Standby mode.
• Ensure that the protocol that you want to run has been properly selected at both ends and the time slots have been allocated if applicable.
Status 1 (STS1) LED is OFF
WPIM-T1, WPIM-E1, WPIM-DI, or WPIM-DDS Installed in CSX400
The port is operating normally. If it is not, and this LED is OFF the port may be disabled.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
CSX400 and CSX400-DC User’s Guide 209
Troubleshooting
WPIM-SYNC Installed in CSX400
The port is operating normally. If it is not, and this LED is OFF the port may be disabled or RTS may be inactive.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
WPIM-HDSL Installed in CSX400
The port is disabled or has been placed into Loopback Test mode.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
• Use QuickSET or Local Management to make sure that the WAN interface on the Remote device is configured correctly.
WPIM-S/T Installed in CSX400
The port is operating normally and ISDN BRI channels B1 and B2 are not active. If it is not, and this LED is always OFF, the port may be disabled.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
Status 1 (STS1) LED is RED
WPIM-T1, WPIM-E1, or WPIM-DI Installed in CSX400 is in RED Alarm Mode
A RED alarm indicates that the WAN connection is not receiving proper framing or has lost framing.
• Verify the use of proper cabling on the WAN connection.
• Check Frame Type selection on the WAN Physical Configuration and line coding.
• Possible bad cabling between Telco and CSX400.
210 CSX400 and CSX400-DC User’s Guide
Troubleshooting
WPIM-HDSL Installed in CSX400
WPIM-HDSL is configured for either Full or Fractional T1 and the WPIM is not able to establish synchronization on Loop 1 with the remote HDSL circuit.
• Use QuickSET or Local Management to verify that one of the WPIM-HDSLs is involved in the connection is set to Master (Local) Timing and that the other one is set to Slave (Loop) Timing.
• Verify the use of proper cabling for the HDSL connections. Category 3 or Category 5
Unshielded Twisted Pair copper wiring is required. One pair (2 wires) for Fractional T1, two pair (4 wires) for Full T1. The presence of bridged taps and multiple wire segments connected together to form the loop may reduce the maximum distance usable between the Remote and
Local devices. Wire gauge has an impact on the distance which can be supported as well. The maximum distance is 12,000 feet using 24 AWG wiring.
• Verify the gauge and condition of the wire. A trained line technician may be necessary to determine this.
• Verify that the distance between the Remote and Local units is less than 12,000 Feet.
Status 1 (STS1) LED is AMBER
WPIM-DDS Installed in CSX400
The DDS circuit is Out of Service (OOS).
• Contact your WAN DDS Service Provider and have them test the operation of your DDS circuit.
Status 1 (STS1) LED is GREEN
WPIM-SYNC Installed in CSX400
The Port is operating normally; Request to Send (RTS) has been activated by your WAN device. If it is not, use the following steps:
• Use QuickSET or Local Management to make sure that the WAN interface on the local device is configured properly.
• Verify the cabling being used between the CSX400 and the CSU/DSU.
CSX400 and CSX400-DC User’s Guide 211
Troubleshooting
WPIM-HDSL is installed in CSX400
The Port is operating normally, Loop 1 has synchronized with the HDSL circuit at the remote end.
WPIM-S/T is installed in CSX400
The Port is operating normally, ISDN BRI channel B1 or B2 or both are active.
Status 2 (STS2) LED is OFF
WPIM-T1, WPIM-E1, WPIM-DI, or WPIM-DDS Installed in CSX400
The port is operating normally. If it is not, and this LED is OFF the port may be disabled.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
WPIM-SYNC Installed in CSX400
The port is operating normally. If it is not, and this LED is OFF the port may be disabled or CTS may be inactive from the CSU/DSU connected to the CSX400.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
WPIM-HDSL Installed in CSX400
The port is in Fractional T1 mode and is operating normally. If it is not, the port is disabled or has been placed into Loopback Test mode.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
• Use QuickSET or Local Management to make sure that the WAN interface on the Remote device is configured correctly.
WPIM-S/T Installed in CSX400
The port is operating normally and ISDN BRI channel B2 is not active. If it is not, and this LED is always OFF, the port may be disabled.
• Use QuickSET or Local Management to make sure that the WAN interface on the Local device is configured correctly.
212 CSX400 and CSX400-DC User’s Guide
Troubleshooting
Status 2 (STS 2) LED is RED WPIM-HDSL Installed in CSX400
WPIM-HDSL is configured for either Full T1 and the WPIM is not able to establish synchronization on Loop 2 with the remote HDSL circuit.
• Verify using QuickSET of Local Management that one of the WPIM-HDSL is involved in the connection is set to Master (Local) Timing and that the other one is set to Slave (Loop) Timing.
• Verify the use of proper cabling for the HDSL connections. Category 3 or Category 5
Unshielded Twisted Pair copper wiring is required. One pair (2 wires) for Fractional T1, two pair (4 wires) for Full T1. The presence of bridged taps and multiple wire segments connected together to form the loop may reduce the maximum distance usable between the Remote and
Local devices. Wire gauge has an impact on the distance which can be supported as well. The maximum distance is 12,000 feet using 24 AWG wiring.
• Verify the gauge and condition of the wire. A trained line technician may be necessary to determine this.
• Verify that the distance between the Remote and Local units is less than 12,000 Feet.
Status 2 (STS2) LED is AMBER
WPIM-T1, WPIM-E1, or WPIM-DI Installed in CSX400
The device is in Yellow alarm mode. A Yellow alarm indicates that the CSX400 is receiving proper framing from the Telco, but the Telco is not receiving proper framing.
• Check for faulty or incorrect cabling between Telco and CSX400.
• Request that the Telco verify the configuration and operation of the circuit.
Status 2 (STS2) LED is GREEN
WPIM-SYNC Installed in CSX400
The Port is operating normally, Clear to Send (CTS) has been received by your WAN device.
• If it is not, check STS 1 to determine if the Port is Sending a Request to Send (RTS) to the CSU/
DSU it is connected to.
• Verify the cabling being used between the CSX400 and the CSU/DSU.
• Check the CSU/DSU for proper operation.
CSX400 and CSX400-DC User’s Guide 213
Troubleshooting
WPIM-HDSL Installed in CSX400
The port is operating normally, Loop 2 has synchronized with the HDSL circuit at the remote end
(Full T1 mode only).
WPIM-S/T Installed in CSX400
The port is operating normally, ISDN BRI channel B2 is active.
Test (TST) LED is AMBER (blinking)
The device is in test mode.
• The CSX400 is running its Power-up Diagnostic Tests.
• Loopback Testing is underway on a WAN circuit.
Investigating Software Configuration Problems
Software problems usually occur when your software configuration contains incomplete or incorrect information.
Connection to Device Fails During Software Configuration
• For a LAN connection, verify that the IP address matches the IP address previously stored into the configuration of the router. You must have previously (through QuickSET) set the Ethernet
LAN IP address and Subnet Mask, enabled IP routing, saved the Ethernet configuration changes and rebooted the router for the new IP address to take effect.
• Check that your LAN cable is wired correctly and each end securely plugged in.
• Make sure that an IP route exists between your local PC and the CSX400. The PC and CSX400 must be on the same IP subnetwork or the CSX400 must be reachable through a router on your
LAN.
• Check Network TCP/IP properties under Windows 95 or Windows NT, as described in the
Read Me First! document.
214 CSX400 and CSX400-DC User’s Guide
Troubleshooting
User Cannot Communicate with Remote Network Station
If Bridging,
• Check that the Bridging Default Destination is set.
• Check that bridging to/from the remote router is set on.
• Be sure to reboot if you have made any bridging destination or control changes.
If TCP/IP Routing,
• Check that TCP/IP Routing is set on and is enabled at the remote end.
• Check that the IP address of the LAN beyond the remote router is correct, as well as the associated Subnet Mask.
• If the remote router WAN IP address and Subnet Mask are required, check that they have been specified correctly.
• Check that, if required, the source and remote WAN IP addresses are on the subnetwork.
• Check that you have seeded the routing table, if RIP is not allowed to flow on the WAN link.
• Be sure to reboot if you have made any IP address, control or protocol option changes.
CSX400 and CSX400-DC User’s Guide 215
Troubleshooting
216 CSX400 and CSX400-DC User’s Guide
A
EPIM Specifications
Introduction
The CSX400 provides two ports for Cabletron Systems EPIMs. EPIMs allow connection to the main network using different media types. The following sections explain the specifications of the variety of EPIMs Cabletron Systems offers.
EPIM-T
The EPIM-T is an RJ45 connector supporting UTP cabling. It has an internal Cabletron Systems
TPT-T 10BASE-T Twisted Pair Transceiver.
The slide switch on the EPIM-T determines the crossover status of the cable pairs. If the switch is on the X side, the pairs are internally crossed over. If the switch is on the = side, the pairs are not internally crossed over.
Figure 78 shows the pinouts for the EPIM-T in both crossover positions.
Position X
(crossed over)
1. RX+
2. RX-
3. TX+
4. NC
5. NC
6. TX-
7. NC
8. NC
Position =
(not crossed over)
1. TX+
2. TX-
3. RX+
4. NC
5. NC
6. RX-
7. NC
8. NC
Figure 78 EPIM-T Pinouts
CSX400 and CSX400-DC User’s Guide 217
EPIM Specifications
EPIM-F1 and EPIM-F2
The EPIM-F1 and EPIM-F2 support Multimode Fiber Optic cabling. Each EPIM has an internal
Cabletron Systems FOT-F Fiber Optic Transceiver. The EPIM-F1 is equipped with SMA
Connectors and the EPIM-F2 is equipped with ST Connectors.
shows both EPIMs.
Specifications for the EPIMs are listed in
Figure 79 EPIM-F1 and EPIM-F2
Table 29 EPIM-F1 & EPIM-F2 Specifications
Parameter Typical Value
Worst
Case
Receive
Sensitivity
Peak Input
Power
-30.5 dBm
-7.6 dBm
-28.0 dBm
-8.2 dBm
Table 30 provides transmitter power parameters.
218 CSX400 and CSX400-DC User’s Guide
EPIM Specifications
NOTE
Parameter
50/125
µ m fiber
62.5/125
µ m fiber
100/140
µ m fiber
Error Rate
Table 30 Transmitter Power
Typical Value
-13.0 dBm
-10.0 dBm
-7.0 dBm
Better than 10 -10
Worst
Case
-15.0 dBm
-12.0 dBm
-9.0 dBm
Worst
Case
Budget
13.0 dB
16.0 dB
19.0 dB
Typical
Budget
17.5 dB
20.5 dB
23.5 dB
The transmitter power levels and receive sensitivity levels listed are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given above to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed
(i.e., -30.5 dBm peak = -33.5 dBm average).
CSX400 and CSX400-DC User’s Guide 219
EPIM Specifications
EPIM-F3
The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal Cabletron Systems
FOT-F Fiber Optic Transceiver and is equipped with ST Connectors. Figure 80 shows the
EPIM-F3. Specifications for the EPIM-F3 are listed in
Figure 80 EPIM-F3
NOTE
Transmitter Power decreases as temperatures rise and increases as temperatures fall.
Use the Output Power Coefficient to calculate increased or decreased power output for your operating environment. For example, the typical power output at 25
°
C is
-16.4 dBm. For a 4
°
C temperature increase, multiply the typical coefficient (-0.15 dBm) by four and add the result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).
Table 31 EPIM-F3 Specifications
Typical Minimum Parameter
Transmitter Peak Wave Length
Spectral Width
Rise Time
Fall Time
Duty Cycle
Bit Error Rate
1300 nm
60 nm
3.0 nsec
2.5 nsec
50.1%
Better than 10 -10
1270 nm
–
2.7 nsec
2.2 nsec
49.6%
Maximum
1330 nm
100 nm
5.0 nsec
5.0 nsec
50.7%
NOTE
The transmitter power levels given above are Peak Power Levels after optical overshoot. You must use a Peak Power Meter to correctly compare the values given above to those measured on any particular port. If you are measuring power levels with an Average Power Meter, add 3 dBm to the average power measurement to correctly compare the average power values measured to the values listed above (i.e., -33.5 dBm average + 3 dB = -30.5 dBm peak).
220 CSX400 and CSX400-DC User’s Guide
EPIM Specifications
EPIM-C
The EPIM-C supports thin coaxial cabling and is equipped with an internal Cabletron Systems
TMS-3 Transceiver. You can use the TERM switch on the front of the EPIM-C to set the internal
50-ohm terminator. This eliminates the need to connect the port to a T-connector and terminator.
Figure 81 shows the setting for the terminator switch.
Internal Termination Switch
= On (internally terminated)
= Off (need external termination)
Figure 81 EPIM-C
Connector Type
This connector type is a BNC receptacle with gold center contact for use with BNC type
T-connectors and RG58 coaxial cable.
Grounding
!
CAUTION
For safety reasons, only one end of a coaxial segment should be connected to earth ground. Connection to earth ground at more than one point on the segment may cause dangerous ground currents.
The BNC port of the Coaxial Interface Modules is not connected to earth ground.
CSX400 and CSX400-DC User’s Guide 221
EPIM Specifications
EPIM-A and EPIM-X (AUI Port)
The EPIM-A is a DB15 female connector used to attach segments to an external transceiver. The
EPIM-X is equipped with dual internal transceivers. It has a DB15 male connector used to attach segments to an AUI cable.
Figure 82 shows both modules and Table 32 provides the DB15
pinouts.
!
CAUTION
The EPIM-A is equipped with a fuse (F1) to protect against risk of fire. For continued protection against the risk of fire, replace fuse F1only with the same type and rating of fuse (1A, F250V).
Pin Number
7
9
5
6
3
4
1
2
Figure 82 The EPIM-A and EPIM-X
Table 32 DB15 Pinouts
Represents Pin Number
Logic Ref.
Collision +
Transmit +
Logic Ref.
Receive +
Power Return
No Connection
Collision -
10
11
12
13
14
15
Connector Shell
Represents
Transmit -
Logic Ref.
Receive -
Power (+12Vdc)
Logic Ref.
No Connection
Positive Ground
222 CSX400 and CSX400-DC User’s Guide
B
WPIM Cable Specifications
NOTE
For all WPIM cables, there is part number information for ordering a standard 20-foot cable or a specified length of cable. The number 20 followed by the part number denotes the standard 20-foot cable. The letter “L” denotes the specified length required in feet or meters. For example: 9372095-3 denotes a 3 foot cable; 9372095-3M denotes a 3-meter cable.
WPIM-T1
This section provides the Cabletron Systems part number and connector specifications for
WPIM-T1 interface cables.
Table 33 provides connector type and part number information.
Table 33 T-1 Interface Cable Part Numbers
Connector Type Part Number
RJ48C 9372094
Table 34 provides RJ48 connector pin assignments.
Table 34 T-1 Connector Pin Assignments
Pin Signal
7
8
5
6
3
4
1
2
Receive Ring
Receive Tip
Not Used
Transmit Ring
Transmit Tip
Not Used
Shield Ground
Shield Ground
CSX400 and CSX400-DC User’s Guide 223
WPIM Cable Specifications
Table 35 provides RJ48 DTE pin assignments.
Table 35 DTE Pin Assignments
Pin Signal
6
7
4
5
8
1
2
3
Receive Ring
Receive Tip
Not Used
Transmit Ring
Transmit Tip
Not Used
Shield Ground
Shield Ground
Table 36 provides RJ48 network pin assignments.
Table 36 Network Pin Assignments
5
6
3
4
7
8
Pin Signal
1
2
Receive Ring
Receive Tip
Not Used
Transmit Ring
Transmit Tip
Not Used
Not Used
Not Used
224 CSX400 and CSX400-DC User’s Guide
WPIM Cable Specifications
WPIM-SY
This section provides the Cabletron Systems part number and connector specifications for the
WPIM-SY interface cables.
Table 37 provides the cable and interface types, electrical types, and part numbers for the
WPIM-SY.
Table 37 WPIM-SY Interface Cables
Cable and Interface Type
RS449
V.35
RS232
X.21
RS530
RS530 ALT A
RS530A
RS530A ALT A
Electrical Type
RS422
V.35
RS232
X.21
RS422
RS422
RS422
RS422
Part Number
9380120
9380121
9380122
9380123
9380124
9380125
9380126
9380127
CSX400 and CSX400-DC User’s Guide 225
WPIM Cable Specifications
EIA-449
Table 38 shows the connector number, cable assembly description, and connector type.
Table 38 EIA-449 Interface
Connector Number Cable Assembly Description Connector Type
1
2
EIA-530A ALT A to EIA-449
Sub DB 26-pin male connector
DB-37 pin male connector
Table 39 provides pin assignments for the EIA-449 interface cable.
Table 39 EIA-449 Interface Cable Pin Assignment
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
DB
DD
DA
DCE
DTE
DCE
DTE
DCE
PIN
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B
Clear to Send A
Clear to Send B
Request to Send A
Request to Send B
Transmit Signal Timing A 15
Transmit Signal Timing B 12
Receive Signal Timing A 17
Receive Signal Timing B 9
Transmit Signal Timing A 24
Transmit Signal Timing B 11
5
13
4
19
2
14
3
16
PAIR
A
B
C
D
E
F
G
PIN
Connector 2 EIA-449
NAME
4
22
Send Data A
Send Data B
6 Receive Data A
24 Receive Data B
9 Clear to Send A
27 Clear to Send B
7 Request to Send A
25 Request to Send B
5 Send Timing A
23 Send Timing B
8 Receive Timing A
26 Receive Timing B
17 Terminal Timing A
35 Terminal Timing B
DIRECT
TO
MNEMONIC
DCE
DTE
DCE
DTE
DCE
SD
RD
CS
RS
ST
RT
TT
226 CSX400 and CSX400-DC User’s Guide
WPIM Cable Specifications
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
CE
TM
CC
CD
AC
DTE
DCE
Ring Indicator
Test Mode
DCE Ready
DTE Ready
SHIELD
Signal Common
AB
Table 39 EIA-449 Interface Cable Pin Assignment (Continued)
Signal Common
PIN
22
25
6
20
1
23
7
PAIR
PIN
Connector 2 EIA-449
NAME
DIRECT
TO
MNEMONIC
15
18
Incoming Call
Test Mode
11 Data Mode
12 Terminal Ready
20 Receive Common
19
30
37
Send Common
Terminal Ready B
Signal Ground
DTE
DCE
IC
TM
DM
TR
RC
SG
TR_B
SC
V.35
Table 40 shows the connector number, cable assembly description, and connector type.
Table 40 V.35 Interface
Connector Number Cable Assembly Description
1
2
EIA-530A ALT A to V.35
Connector Type
Sub DB 26-pin male
M Series 34-pin male
Table 41 provides pin assignments for the V.35 interface cable.
Table 41 V.35 Interface Cable Pin Assignment
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
PIN
DCE
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B DTE
Clear to Send A 5
DCE Request to Send A 4
2
14
3
16
PAIR
A
B
PIN
Connector 2 V.35
NAME
P Transmit Data A
S Transmit Data B
R Receive Data A
T Receive Data B
DIRECT
TO
MNEMONIC
DCE
DTE
C D Ready to Send A
D C Request to Send A DCE
103
104
106
105
CSX400 and CSX400-DC User’s Guide 227
WPIM Cable Specifications
Table 41 V.35 Interface Cable Pin Assignment (Continued)
RL
LL
AC
AB
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
DB
DD
DA
CE
TM
CC
CD
DTE
DCE
DTE
DCE
NAME
Transmit Signal
Timing A
Transmit Signal
Timing B
Receive Signal
Timing A
Receive Signal
Timing B
Transmit Signal
Timing A
Transmit Signal
Timing B
Ring Indicator
Test Mode
DCE Ready
DTE Ready
Remote Loopback
Local Loopback
SHIELD
Signal Common
Signal Common
PIN
PAIR
15
12
17
9
24
11
22
25
6
20
21
18
1
23
7
E
F
G
PIN
Connector 2 V.35
NAME
DIRECT
TO
MNEMONIC
Y
AA
V
X
Transmitter Signal
Timing A
Transmitter Signal
Timing B
Receiver Signal
Timing A
Receiver Signal
Timing B
U
W
Transmitter Signal
Timing A
Transmitter Signal
Timing B
J Calling Indicator
NN Test Indicator
E Data Set Ready
H
N
Data Terminal
Ready
Loopback
Maintenance
L Local Loopback
DRAIN
B Signal Common
B Signal Common
DTE
DCE
DTE
DCE
114
115
113
125
142
107
108
140
141
102
102
228 CSX400 and CSX400-DC User’s Guide
WPIM Cable Specifications
EIA-232
Table 42 shows the connector number, cable assembly description, and connector type.
Table 42 EIA-232 Interface
Connector Number Cable Assembly Description
1
2
EIA-530A ALT A to EIA-232
Connector Type
Sub DB 26-pin male
DB-25 pin male
Table 43 provides pin assignments for the EIA-232 interface cable.
Table 43 EIA-232 Interface Cable Pin Assignment
BA
BB
CB
CA
DB
DD
DA
CE
RL
LL
TM
CC
CD
AC
AB
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME PIN PIN
Connector 2 EIA-232
NAME
DIRECT
TO
MNEMONIC
DCE DCE
DTE
DCE
DTE
DCE
DTE
DCE
Transmit Data
Receive Data
Clear to Send
Request to Send
Transmit Signal Timing
Receive Signal Timing
2 2
3 3
Transmit Data
Receive Data
5 5 Clear to Send
4 4 Request to Send
15
17
15
17
Transmitter Signal
Timing
Receiver Signal
Timing
Transmit Signal Timing
Ring Indicator
Remote Loopback
24
22
21
24
22
21
Transmitter Signal
Timing
Ring Indicator
Loopback
Maintenance
DTE
DCE
Local Loopback
Test Mode
DCE Ready
DTE Ready
SHIELD
Signal Common
Signal Common
18 18 Local Loopback
25 25 Test Indicator
6 6
20 20
DCE Ready
DTE Ready
1
23 7 Signal Common
7 7 Signal Common
DTE
DCE
DTE
DCE
DTE
DCE
DTE
DCE
BA
BB
CB
CA
DB
DD
DA
CE
RL
LL
TM
CC
CD
AB
AB
CSX400 and CSX400-DC User’s Guide 229
WPIM Cable Specifications
X.21
Table 44 shows the connector number, cable assembly description, and connector type.
Table 44 X.21 Interface
Connector Number Cable Assembly Description Connector Type
1
2
EIA-530A ALT A to X.21
Sub DB 26-pin male
DB-15 pin male
Table 45 provides pin assignments for the X.21 interface cable.
Table 45 X.21 Interface Cable Pin Assignment
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
DB
AC
AB
DCE
DTE
DTE
DCE
DTE
PIN
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B
Clear to Send A
Clear to Send B
Request to Send A
Request to Send B
Transmit Signal Timing A
Receive Signal Timing A
Transmit Signal Timing B
Receive Signal Timing B
SHIELD
DTE Common
DCE Common
1
7
23
5
13
4
19
17
15
9
12
2
14
3
16
PAIR
A
B
C
D
E
PIN
6
13
8
5
12
3
10
2
9
4
11
Signal Ground
Connector 2 X.21
NAME
DIRECT
TO
MNEMONIC
Transmit A
Transmit B
Receive A
Receive B
Indication A
Indication B
Control A
Control B
DCE
DTE
DTE
DCE
Signal Element
Timing A
DTE
Signal Element
Timing B
DRAIN
T
R
I
C
S
G
230 CSX400 and CSX400-DC User’s Guide
WPIM Cable Specifications
EIA-530, EIA-530 ALT A, EIA-530 A, and EIA-530 A ALT A
Table 46 shows the connector number, cable assembly description, and connector type for the
EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A, interface cables.
Table 46 EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A Interfaces
Connector Number Cable Assembly Description Connector Type
1
2
1
2
1
2
1
2
EIA-530A ALT A to EIA-530
EIA-530A ALT A to EIA-530 ALT A
EIA-530A ALT A to EIA-530A
EIA-530A ALT A to EIA -530A ALT A
Sub DB 26-pin male
DB 25-pin male
Sub DB 26-pin male
Sub DB26-pin male
Sub DB 26-pin male
DB 25-pin male
Sub DB 26-pin male
Sub DB 26-pin male
Table 47 provides the cable pin assignments for the EIA-530, EIA-530 ALT A, EIA-530A, and
EIA-530A ALT A, interface cables.
Table 47 EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A Interface Cable Pin Assignments
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
NAME
BA
BB
CB
CA
DCE
DTE
DCE
Transmit Data A
Transmit Data B
Receive Data A
Receive Data B
Clear to Send A
Clear to Send B
Request to Send A
Request to Send B
PIN
2
14
3
16
5
13
4
19
PAIR
A
B
C
D
PIN
Connector 2 EIA-530
NAME
DIRECT
TO
MNEMONIC
2 Transmit Data A
14 Transmit Data B
3 Receive Data A
16 Receive Data B
5 Clear to Send A
13 Clear to Send B
4 Request to Send A
19 Request to Send B
DCE
DTE
DCE
BA
BB
CB
CA
CSX400 and CSX400-DC User’s Guide 231
WPIM Cable Specifications
Table 47 EIA-530, EIA-530 ALT A, EIA-530A, and EIA-530A ALT A Interface Cable Pin Assignments a b
DB
DD
DA
RL
LL
TM
CC
CD
AC
AC
AB
CE
Connector 1 EIA-530A ALT A
MNEMONIC
DIRECT
TO
DTE
DCE
DTE
DCE
DTE
NAME
Transmit Signal Timing A 15
Transmit Signal Timing B 12
Receive Signal Timing A 17
Receive Signal Timing B
Remote Loopback
SHIELD
Local Loopback
Test Mode
DCE Ready
DTE Ready
Signal Common
Signal Common
Signal Common
Ring Indicator
PIN
PAIR
9
Transmit Signal Timing A 24
Transmit Signal Timing B 11
21
18
25
6
20
1
23
23
7
22
E
F
G
PIN
Connector 2 EIA-530
NAME
DIRECT
TO
MNEMONIC
15
12
17
9
Transmit Signal
Timing A
Transmit Signal
Timing B
Receive Signal
Timing A
Receive Signal
Timing B
7 Signal Common
23 Signal Common
7 Signal Common
22 Ring Indicator
DTE
24
11
Transmit Signal
Timing A
Transmit Signal
Timing B
DCE
21 Remote Loopback
18 Local Loopback
25
6
20
Test Mode
DCE Ready
DTE Ready
DRAIN
DTE
DCE
DTE
DB
DD
DA
RL
LL
TM
CC
CD
AC
AC
AB
CE a. This pin assignment only applies to the EIA-530A ALT A interface cable.
b. This pin assignment only applies to the EIA-530A and EIA-530A ALT A interface cables.
232 CSX400 and CSX400-DC User’s Guide
WPIM Cable Specifications
.
WPIM-DDS
This section provides Cabletron Systems part number and connector specifications for the
WPIM-DDS interface cable. The WPIM-DDS has one RJ45 port for a direct connection to a single
Digital Data Service (DDS) circuit.
Table 48 provides cable and interface type, and part number information for the WPIM-DDS
interface cable, and
Table 49 provides network Pin Assignment information for the DDS interface
cable.
Table 48 DDS Interface Cable Part Number
Cable and Interface Type Part Number
DDS 9360119
Table 49 Network Pinout Assignments
PIN SIGNAL
7
8
5
6
3
4
1
2
Transmit Ring
Transmit Tip
Not Used
Not Used
Not Used
Not Used
Receive Tip
Receive Ring
CSX400 and CSX400-DC User’s Guide 233
WPIM Cable Specifications
WPIM-E1
This section provides the Cabletron Systems part number and connector specifications for the
WPIM-E1 interface cable.
Table 50 shows the WPIM-E1 connector number, cable and interface type, connector type and part
number information.
Table 50 WPIM-E1 Connector Information
Connector Number Cable and Interface Type Connector Type Part Number
1
2
E1 RJ45 9372095
Table 51 provides WPIM-E1 network interface cable pin assignments.
Table 51 Network Interface
7
8
5
6
2
3
4
Pin Signal
1 Receive Ring
Receive Tip
Shield Ground
Transmit Ring
Transmit Tip
Shield Ground
Not Used
Not Used
234 CSX400 and CSX400-DC User’s Guide
WPIM Cable Specifications
Table 52 provides WPIM-E1 DTE interface cable pin assignments.
Table 52 DTE Interface
Pin Signal
6
7
4
5
8
1
2
3
Receive Ring
Receive Tip
Shield Ground
Transmit Ring
Transmit Tip
Shield Ground
Not Used
Not Used
Table 53 provides WPIM-E1 RJ45 network interface cable pin assignments.
Table 53 Network Interface
5
6
3
4
7
8
Pin Signal
1
2
Receive Ring
Receive Tip
Not Used
Transmit Ring
Transmit Tip
Not Used
Not Used
Not Used
CSX400 and CSX400-DC User’s Guide 235
WPIM Cable Specifications
WPIM-DI
This section provides Cabletron Systems part number and connector specifications for the
WPIM-DI interface cables.
Table 54 shows the connector number, cable assembly description, cable and interface type,
connector type and part number information for the WPIM-DI interface.
Connector
Number
Table 54 WPIM-DI Connector Information
Cable Assembly Description
Cable and
Interface Type
Connector
Type
Part Number
1
2
Network
Drop and Insert
DI RJ48 9372094
Table 55 provides the WPIM-DI network interface cable pin assignments.
7
8
5
6
3
4
1
2
Table 55 WPIM-DI Network
Pin Signal
Receive Ring
Receive Tip
AC Coupled Ground
Transmit Ring
Transmit Tip
AC Coupled Ground
AC Coupled Ground
AC Coupled Ground
236 CSX400 and CSX400-DC User’s Guide
WPIM Cable Specifications
Table 56 provides the WPIM-DI drop and insert interface cable pin assignments.
Table 56 WPIM-DI Drop and Insert
Pin Signal
6
7
4
5
8
1
2
3
Transmit Ring
Transmit Tip
AC Coupled Ground
Receive Ring
Receive Tip
AC Coupled Ground
AC Coupled Ground
AC Coupled Ground
WPIM-HDSL
This section provides connector specifications for the WPIM-HDSL interface cables. Table 57
provides pin assignments for the RJ-45 network interface connector.
Table 57 WPIM-HDSL Network Interface Cable Pin Assignments
Pin Signal
7
8
5
6
3
4
1
2
HDSL Loop 1 (Ring1)
HDSL Loop 1 (Tip1)
Not Used
HDSL Loop 2 (Ring2)
HDSL Loop 2 (Tip2)
Not Used
Not Used
Chassis Ground
CSX400 and CSX400-DC User’s Guide 237
WPIM Cable Specifications
WPIM-S/T
This section provides connector specifications for the WPIM-S/T interface cable.
provides pin assignments for the RJ-45 network interface connector.
Table 58 WPIM-S/T Network Interface Cable Pin Assignments
Pin Signal
6
7
4
5
8
1
2
3
Not Used
Not Used
Transmit +
Receive +
Receive -
Transmit -
Not Used
Not Used
238 CSX400 and CSX400-DC User’s Guide
C
Specifications and Standards Compliance
This chapter contains hardware specifications, and safety and compliance standards for the
CSX400, CSX400-DC, and for the individual WPIMs that can be configured with these devices.
CSX400, CSX400-DC, and WPIM Environmental Requirements
Operating Temperature
Storage Temperature
Operating Humidity
Table 59 Environmental Specifications
5
°
to 40
°
C (41
°
to 104
°
F)
-30
°
to 73
°
C (-22
°
to 164
°
F)
5% to 90% RH, non-condensing
CSX400 Specifications and Compliance Standards
WAN Interface
LAN Interface
Other Interfaces
Processor
Width
Height
Depth
Weight
Power Supply
Voltage
Frequency
Power Consumption
Table 60 Hardware Specifications
2 WPIM ports
2 EPIM ports
AC Power Connector
Intel i960 66 Mhz
17 inches (43.2 cm)
1.75 inches (4.5 cm)
13.5 inches (34.3 cm)
5.67 lbs (2.58 kg)
Built-in power supply
100–125 Vac ~ 1.0 A, 200–240 Vac ~ 0.5 A
50/60 Hz
100 Watts maximum
CSX400 and CSX400-DC User’s Guide 239
Specifications and Standards Compliance
CSX400-DC Specifications and Compliance Standards
WAN Interface
LAN Interface
Other Interfaces
Processor
Width
Height
Depth
Weight
Power Supply
Voltage
Power Consumption
Heat Dissipation
Table 61 Hardware Specifications
2 WPIM ports
2 EPIM ports dc power terminal strip
Intel i960 66 Mhz
17 in (43.2 cm)
1.75 in (4.5 cm)
13.5 in (34.3 cm)
5.67 lb (2.58 kg)
Built-in power supply
48/60 Vdc ~ 3.5 A
100 Watts maximum
341.2 Btu/hr
CSX400 and CSX400-DC Regulatory Compliance
Safety — This unit meets the safety requirements of UL 1950, CSA C22.2 No. 950 and
EN 60950, IEC 950, and 73/23/EEC.
EMC — This unit meets the EMC requirements of FCC Part 15, EN 55022, EN 50082-1,
89/336/EEC, AS/NZS 3548, CSA C108.8, and VCCI V-3.
CSX400-DC Regulatory Compliance (Only)
NEBS —
SR-3580.
This unit meets a minimum of Level 1 NEBS requirements in accordance with Bellcore
240 CSX400 and CSX400-DC User’s Guide
Specifications and Standards Compliance
Individual WPIM Regulatory Compliance
The following sections provide regulatory compliance standards for the WPIM-TI, WPIM-SY,
WPIM-DDS, WPIM-E1, WPIM-DI, WPIM-S/T, and the WPIM-HDSL. Cabletron Systems reserves the right to change these specifications at any time without notice.
WPIM-TI
This section describes the environmental specifications and safety and approval requirements for the WPIM-T1.
Safety — This unit meets the safety requirements of UL 1950, and CSA C22.2 No. 950.
Electromagnetic Compatibility (EMC) —
15, VCCI V-3, and CSA108.8.
This unit meets the EMC requirements of FCC Part
NEBS —
SR 3580.
This unit meets a minimum of Level 1 NEBS requirements in accordance with Bellcore
TELECOM — FCC Part 68, CS-03.
CSX400 and CSX400-DC User’s Guide 241
Specifications and Standards Compliance
WPIM-SY
This section describes the environmental specifications and safety and approval requirements for the WPIM-SY.
Safety — This unit meets the safety requirements of UL1950, CSA C22.2 No. 950, EN 60950,
IEC 950, and 73/23/EEC.
EMI — This unit meets the EMI requirements of FCC Part 15, EN 55022, EN 50082-1, AS/NZS
3548, 89/336/EEC, CSA108.8, and VCCI V-3.
TELECOM — 91/263/EEC, and NET 2.
WPIM-DDS
This section describes the environmental specifications and safety and approval requirements for the WPIM-DDS.
Safety — This unit meets the safety requirements of UL1950, and CSA C22.2 No. 950.
(EMC) — This unit meets the EMC requirements of FCC Part 15, CSA108.8, and VCCI V-3.
NEBS —
SR 3580.
This unit meets a minimum of Level 1 NEBS requirements in accordance with Bellcore
TELECOM — FCC Part 68, CS-03.
242 CSX400 and CSX400-DC User’s Guide
Specifications and Standards Compliance
WPIM-E1
This section describes the environmental specifications and safety and approval requirements for the WPIM-E1.
Safety —
NZS 3260.
This unit meets the safety requirements of EN 60950, IEC 950, 73/23/EEC and AS/
Electromagnetic Compatibility (EMC) — This unit meets the EMI requirements of EN 55022,
EN 50082-1, AS/NZS 3548, and 89/336/EEC.
TELECOM — 91/263/EEC, CTR 12, TS 001, and TS 016.
WPIM-DI
This section describes the environmental specifications and safety and approval requirements for the WPIM-DI.
Safety — This unit meets the safety requirements of UL1950, and CSA C22.2 No. 950.
Electromagnetic Compatibility (EMC) —
15, VCCI V-3, and CSA108.8.
This unit meets the EMI requirements of FCC Part
TELECOM — The WPIM-DI meets FCC Part 68 and CS-03.
WPIM-S/T
This section describes the environmental specifications and safety and approval requirements for the WPIM-S/T.
Safety — This unit meets the safety requirements of UC1950, CSA 22.2 No. 950, EN 60950,
IEC 950 73/23/EEC.
Electromagnetic Compatibility (EMC) — This unit meets the EMC requirements of FCC
Part 15, EN 55022, VCCI V-3, CSA/08.8 EN 50082-1, AS/NZS 3548, 89/336/EEC.
Telcom (Future) — FCC part 68, CS-03.
CSX400 and CSX400-DC User’s Guide 243
Specifications and Standards Compliance
WPIM-HDSL
This section describes the environmental specifications and safety and approval requirements for the WPIM-HDSL.
Safety — This unit meets the safety requirements of UC1950, CSA 22.2 No. 950, EN 60950,
IEC 950 73/23/EEC.
Electromagnetic Compatibility (EMC) — This unit meets the EMC requirements of FCC
Part 15, EN 55022, VCCI V-3, CSA/08.8 EN 50082-1, AS/NZS 3548, 89/336/EEC.
NEBS —
GR 1089.
This unit meets a minimum of Level 1 NEBS requirements in accordance with Bellcore
244 CSX400 and CSX400-DC User’s Guide
D
Network Information Worksheets
Configuration Section
System Settings
System Settings
Dial Authentication
Password
System Settings
ISDN Settings
System Settings
Ethernet IP Address
System Settings
Ethernet IPX Network #
Item
Table 62 CSX400
Router Name
Message
Dial Authentication
Password/Secret
ISDN SPID #1
ISDN SPID #2
ISDN Directory Number #1
ISDN Directory Number #2
ISDN Switch Type
Ethernet IP Address and
Subnet Mask
Ethernet IPX Network
Number
Setting
Configuration Section
Remote Router Database
Dial Settings
Remote Router Database
Security
Remote Router Database
Bridging
Table 63 Remote Router
Item
ISDN Phone #1 ISDN
Phone #2 Disconnect Timer
Value Maximum Links
Minimum Links Threshold
Bandwidth Direction
Minimum Authentication
Remote Router’s Password/
Secret
Bridging On/Off Spanning
Tree On/Off
Setting
CSX400 and CSX400-DC User’s Guide 245
Network Information Worksheets
Configuration Section
Table 63 Remote Router (Continued)
Item Setting
Remote Router Database
TCP/IP Route Addresses
Remote Network’s IP
Addresses, Subnet Masks, and Metrics Source WAN IP
Address and Subnet Mask a
Remote Router Database
IPX Routes
Remote WAN IP Address and Subnet Mask b
IPX Routes: Network
Number, Hop Count and
Ticks
Remote Router Database
IPX SAPs
SAPs: Server Name, Server
Type, Network Number,
Node Number and Sockets
WAN Network Number a. Used only in PPP numbered mode of addressing b. Used only in PPP numbered mode of addressing
Make one chart for each remote router in the remote router database.
NOTE
Configuration Section
Bridging/ Routing
Table 64 Bridging and Routing Controls
Setting Item
Default Remote Bridging
Destination
TCP/IP Routing On/Off
Internet Firewall On/Off
IPX Routing On/Off
246 CSX400 and CSX400-DC User’s Guide
E
FCC Part 68 - User’s Information For CSX400 and CSX400-DC
The following instructions are to ensure compliance with the Federal Communications
Commission (FCC) Rules, Part 68:
1.
All connections to the WPIM-T1, WPIM-DI and WPIM-DDS must be made using standard plugs and jacks.
a.
The WPIM-S/T must only be connected to the network connected behind an FCC Part 68 registered channel service unit. Direct connection is not allowed.
2.
Before connecting your unit, you must inform the local telephone company of the following information:
Table 65 WPIM-DI and WPIM-T1
Port ID
WPIM-DI
WPIM-T1
REN/SOC
6.0N
FIC
04DU9-BN
04DU9-DN
04DU9-1KN
04DU9-1SN
04DU9-1ZN
Table 66 WPIM-DDS (Only)
USOC
RJ48C
RJ48X
USOC
RJ48S
Port ID
WPIM-DDS
REN/SOC
6.0N
FIC
04DU5-56
04DU5-64
Table 67 WPIM-S/T (Only)
Port ID REN/SOC
(BR) WPIM-ST 6.0P
FIC
N/A (XD)
USOC
N/A (XD)
CSX400 and CSX400-DC User’s Guide 247
FCC Part 68 - User’s Information For CSX400 and CSX400-DC
3.
If the unit appears to be malfunctioning, it should be disconnected from the telephone lines until you learn if your equipment or the telephone line is the source of the trouble. If your equipment needs repair, it should not be reconnected until it is repaired.
4.
The CSU/DSU has been designed to prevent harm to the T1 and DDS network. If the telephone company finds that the equipment is exceeding tolerable parameters, the telephone company can temporarily disconnect service, although they will attempt to give advance notice if possible.
5.
Under the FCC Rules, no customer is authorized to repair this equipment. This restriction applies regardless of whether the equipment is in or out of warranty.
6.
If the telephone company alters their equipment in a manner that will affect use of this device, they must give you advance warning so as to give you the opportunity for uninterrupted service.
You will be advised of your right to file a complaint with the FCC.
7.
The attached Affidavit on the following page must be completed by the installer.
8.
In the event of equipment malfunction, all repairs should be performed by our Company or an authorized agent. It is the responsibility of the users requiring service to report the need for service to our Company or to one of our authorized agents. Refer to the
section of
Chapter 1 , for more information on how to get service and support.
248 CSX400 and CSX400-DC User’s Guide
FCC Part 68 - User’s Information For CSX400 and CSX400-DC
AFFIDAVIT FOR THE CONNECTION OFCUSTOMER EQUIPMENT
TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICES
For the work to be performed in the certified territory of
Telco’s name:
State of:
Country of:
I, , of
(Name of Authorized Representative) (Customer Name)
,
(Customer’s Address) (Telephone Number) being duly sworn, state:
I have responsibility for the operation and maintenance of the terminal equipment to be connected to 1.544 Mbps and/or Subrate digital services. The terminal equipment to be connected complies with Part 68 of the Commission’s rules except for the encoded analog content and billing protection specifications. With respect to encoded analog content and billing protection:
• I attest that all operations associated with the establishment, maintenance and adjustment of the digital CPE with respect to encoded analog content and encoded billing information continuously complies with Part 68 of the FCC’s Rules and Regulations.
• The digital CPE does not transmit digital signals containing encoded analog or billing information which is intended to be decoded within the telecommunications network.
• The encoded analog and billing protection is factory set and is not under the control of the customer.
CSX400 and CSX400-DC User’s Guide 249
FCC Part 68 - User’s Information For CSX400 and CSX400-DC
I attest that the operator(s) maintainer(s) of the digital CPE responsible for the establishment, maintenance and adjustment of the encoded analog content and billing information has (have) been trained to perform these functions by successfully completing one of the following: Check appropriate one(s).
a.
A training course provided by the manufacturer/grantee of the equipment used to encode analog signals; or b. A training course provided by the customer or authorized representative, using training materials and instructions provided by the manufacturer/grantee of the equipment used to encode analog signals; or c.
An independent training course (e.g. trade school or technical institution) recognized by the manufacturer/grantee of the equipment used to encode analog signals; or d. In lieu of the proceeding training requirements, the operator(s) maintainer(s) is (are) under the control of a supervisor trained in accordance with above.
I agree to provide with proper documentation
(Telco’s Name) to demonstrate compliance with the information as provided in the proceeding paragraph, if so requested.
(Signature)
(Title)
(Date)
Subscribed and sworn to me this day of , 19 .
(Notary Public)
My commission expires:
250 CSX400 and CSX400-DC User’s Guide
F
Glossary
10BASE-T — IEEE 802.3 standard for the use of Ethernet LAN technology over Unshielded
Twisted Pair wiring, running at 10 Mbps.
ARP — Address Resolution Protocol. An Internet protocol used to bind an IP address to Ethernet/
802.3 addresses.
ASCII — American Standard Code for Information Interchange. It is an 8-bit code for character representation.
AUI — Attachment Unit Interface. An IEEE 802.3 transceiver cable connecting the network device (such as a router) to the MAU (media access unit).
Bandwidth on Demand — Feature providing the capability of adjusting the bandwidth (opening or closing multiple B channels) when the load in traffic increases or decreases.
Bridge — A device that segments network traffic. A bridge maintains a list of each node on the segment and only traffic destined for a node on the adjacent segment is passed across the bridge. A bridge operates at Layer 2 of the OSI reference model.
Bearer (B) Channel — data.
A full duplex ISDN BRI or PRI 64 Kbps channel used for sending user
BRI — Basic Rate Interface. The ISDN interface providing two 64 Kbps B channels for voice, data and video transmission and one 16 Kbps D channel for signaling and data transmission.
CHAP — Challenge Handshake Authentication Protocol. A security protocol supported under point-to-point protocol (PPP) used to prevent unauthorized access to devices and remote networks.
Uses encryption of password, device names and random number generation.
DCE — Data Communications Equipment. Equipment used within a network to transfer data from source to destination such as modems.
D Channel — In ISDN, a full-duplex 16 Kbps channel used for link setup.
CSX400 and CSX400-DC User’s Guide 251
Glossary
Data Compression — Techniques used to reduce the number of bits transferred across the communication links that represent the actual data bits. Compression is used to optimize use of
WAN links and speed data transmission.
DHCP — Dynamic Host Configuration Protocol is a protocol for automatic TCP/IP configuration that provides static and dynamic address allocation and management.
Dial on Demand — Dial up WAN resources are accessed only when remote access is required and released as soon as the resource is no longer needed.
DTE — Data Terminating Equipment. DTE refers to equipment used in a network as the data source and/or destination, such as computers.
DTMF — Dual Tone Multi-Frequency. TOUCHTONE as opposed to Dial Pulse (DP).
DTR — Data Terminal Ready. RS232 signal used for indicating to the DCE the readiness to transmit and receive data.
EtherTalk — AppleTalk protocols running on Ethernet.
Filter — Feature to control the flow of data based on protocol or bridge information. Filters can be specific to allow data through or prevent transmission.
Firewall — A combination of techniques used to protect one network from unknown networks and users on the outside. Firewalls can filter or block traffic and act as a management and network security point where all traffic can be scrutinized.
Frame — A group of data generated by Data Link Layer operation.
HDSL — High bit rate Digital Subscriber Line. A technology to put two-way T1 on a normal unshielded, bridged (but not loaded) twisted pair without using repeaters.
IMUX (Inverse Multiplexing) — The process of splitting a single high-speed channel into multiple signals, transmitting the multiple signals over multiple facilities operating at a lower rate than the original signal, and then recombining the separately-transmitted portions into the original signal at the original rate.
In-Band Signaling — Transmission within the frequency range used for data transmission; i.e., results in use of bandwidth normally reserved for data.
252 CSX400 and CSX400-DC User’s Guide
Glossary
IP — Internet protocol. A network layer protocol which allows a packet to traverse multiple networks on the way to its final destination.
IP Address — Internet address. A 32-bit address assigned to devices that participate in a network using TCP/IP. An IP address consists of four octets separated with periods defining network, optional subnet and host sections.
IPX (Internet Packet Exchange) — and used in NetWare networks.
A proprietary Network layer protocol developed by Novell
ISDN — Integrated Services Digital Network. Digital transmission standard defining communication protocols permitting telephone networks to carry data, voice, fax and other streams.
Leased Line — A telecommunications line between two service points leased from a communications carrier for private use, usually incurring a monthly service rate.
LEDs (Light Emitting Diodes) — Type of indicator lights on the panel of a device.
Local Area Network (LAN) — A network connecting computers over a relatively small geographic area (usually within a single campus or building).
MAC Layer/Address — Media Access Control layer/address defined by the IEEE 802.3 specification which defines media access including framing and error detection. Part of the OSI reference model Data Link layer.
Metric — An algorithm used by routers to determine the best path for transmitting packets to a remote destination based on considerations such as time, delay, cost, etc.
Modem — Modulator/Demodulator. A device that converts digital signals to/from analog signals for transmission over analog communications lines.
Multi-Link Protocol — A protocol, defined in RFC 1717, that defines a way to perform inverse multiplexing on the TCP/IP point-to-point protocol (PPP); i.e., the ability to use multiple serial
WAN channels for transferring one datastream. With MLP, a user can send and receive data over both B channels in an ISDN basic-rate interface connection
NAT — Network Address Translation uses a unique IP address for a WAN interface. This IP
Address is negotiated through PPP or assigned statically by the Internet Service Provider (ISP).
NAT reduces the number of unique IP addresses for all clients using a particular WAN interface to one.
CSX400 and CSX400-DC User’s Guide 253
Glossary
NetWare — A Network Operating System developed by Novell, Inc. providing shared access to files and other network services.
Network Layer — function.
Layer 3 of the OSI reference model that provides the protocol routing
Node — Refers to a termination point for communication links; entity that can access a network.
OSI — Open System Interconnection. An international standard developed by ITU (formally
CCITT) and ISO (International Organization for Standardization) to facilitate data networking multi-vendor interoperability. The OSI Reference Model defines seven layers, each providing specific network functions.
Packet — network.
A group of data that includes a header and usually user data for transmission through a
Ping (Packet Internet Groper) — An echo message, available within the TCP/IP protocol suite, sent to a remote node and returned; used to test the accessibility of the remote node.
PPP (Point-to-Point Protocol) — A Data Link layer protocol that provides asynchronous and synchronous connectivity between computer/network nodes. Includes standardization for security and compression negotiation.
Q.921 — ISDN Data Link layer specification for the user-to-network interface.
Q.931 — ISDN specification for call set-up and signaling on ISDN connections.
RFC — Request for Comment. Documentation describing Internet communications specifications (e.g., Telnet, TFTP). Often these RFCs are used to achieve multi-vendor interoperability during implementation.
RJ11 — Standard 4-wire connectors for telephone lines.
RJ45 — Standard 8-wire connectors used for ISDN lines and 10 BASE-T connections.
RIP (Routing Information Protocol) — Protocols used in IP and IPX for broadcasting open path information between routers to keep routing tables current.
Routing — A Network layer function that determines the path for transmitting packets through a network from source to destination.
254 CSX400 and CSX400-DC User’s Guide
Glossary
RS-232 — EIA standard specifying the physical layer interface used to connect a device to communications media.
Serialization Frames — Frames sent out by servers under IPX to check whether illegal copies of
NetWare are in use on the network.
Service Advertising Protocol — Protocol used in IPX for broadcasting information about services available on the network, such as file servers, CD-ROM drives and modem pools.
SNMP — Simple Network Management Protocol. A widely implemented Internet network management protocol that allows status monitoring, getting/setting of parameters for configuration and control of network devices, such as routers and bridges.
Split B Channels — connection.
Each 64 Kbps ISDN B-channel can be used individually for a separate data
Spoofing — Spoofing is a technique used to remove poll and update service frames from WAN links while ensuring that the network continues to operate normally. Spoofing is employed to minimize dial-up line connection time.
Subnet Address — An extension of the Internet 32-bit addressing scheme that allows the separation of physical or logical networks within the single network number assigned to an organization. TCP/IP entities outside this organization have no knowledge of the internal
“subnetting.”
Subnet Mask — subnetwork.
A 32-bit internet protocol address mask used to identify a particular
TCP/IP — Transmission Control Protocol/Internet Protocol. Refers to a set of internetworking protocols developed by the U.S. Department of Defense that define a two level layered approach for interoperability. TCP provides a connection-oriented Transport layer ensuring end-to-end reliability in data transmission. IP provides for Network layer connectivity using connectionless datagrams.
Telco Cloud — The “cloud” of switched virtual connections over a Wide Area Network (WAN).
TELNET — Internet standard protocol for remote terminal emulation that allows a user to remotely log in to another device and appear as if directly connected.
TFTP — Trivial File Transfer Protocol. A simplified version of the File Transfer Protocol (FTP) allowing for file transfer between computers over a network.
CSX400 and CSX400-DC User’s Guide 255
Glossary
Transparent Bridging — Bridging technique used in Ethernet networks that allows transfer of frames across intermediate nodes using tables associating end nodes with bridging addresses.
Bridges are unknown to the end nodes.
UDP — User Datagram Protocol. A connectionless protocol used to pass packets across an internet network, requiring no handshaking between source and destination.
Watchdog Frames — still logged on.
Frames sent out by servers to clients, under IPX, to verify that clients are
Wide Area Network — A communications network that is geographically dispersed thus requiring links provided by communications carriers.
Workstation — Computer or terminal used by the systems administration or user.
256 CSX400 and CSX400-DC User’s Guide
Numerics
10BASE2
grounding 53 link length 53 specifications 53
10BASE-F attenuation
link length
10BASE-T
impedance 50 insertion loss 50 link length 50 specifications 50
A
AT & T 5ESS switch parameters 27
Attenuation
10BASE-F
B
Bridge Setup
bridge port pair administrative status 151
port administrative status 150
Index
C
Configuring the Network Broadcast Type on a
Configuring the UDP Broadcast Redirector 158
D
DC Power Supply Connections 70
Dynamic Host Configuration Protocol
E
Enabling Forwarding on a port
Enabling Proxy ARP on a port 159
Enabling Routing Services on a port
Enabling the RIP Routing Protocol on a
CSX400 and CSX400-DC User’s Guide 257
Index
F
Flash Download
G
Grounding
H
I
Impedance
Insertion loss
Inverse Multiplexing (IMUX) 10
IP
Configuring the Network Broadcast Type on a
Configuring the UDP Broadcast
Enabling Forwarding on a port 157
Enabling Proxy ARP on a port 159
Enabling Routing Services on a port 157
Enabling the RIP Routing Protocol on a
Selecting a port for configuration 156
IP/IPX QuickSET routing
IPX
enabling forwarding on a port 166
enabling routing services on a port 166
QuickSET IPX configuration 100
BRI line configuration 24 types of switches 24
K
L
Link length
10BASE-F
Local Management
selecting menu screen items 132
Local Management Screen Fields
command fields 128 display fields 128 event message field 128 input fields 128 selection fields 128
258 CSX400 and CSX400-DC User’s Guide
M
MIB
MIB Navigator
other commands 180 special commands 180
N
NETBIOS
Network Address Translator (NAT) 11
Network information worksheets 223
Network Management
P
Point-to-Point Protocol (PPP) 12
R
Rack Mounting
network information tables 38 node numbers 38
source and remote IP addresses 33
Index
CSX400 and CSX400-DC User’s Guide 259
Index
S
Selecting a port for configuration
SNMP Community Names
SNMP Traps
trap community name 143 trap destination 143
Software and firmware upgrades 22
Switches
AT&T 5ESS w/custom software 24
French Delta (VN4) switches 24
KDD (Kokusai Denshin Denwa Co., Ltd.) 24
NET3SW (European Swiss-variant) 24
NTT (Nippon Telegraph and Telephone) 24
T
Telephone switch parameters 26
U
UDP
Configuring the Broadcast Redirector 158
NETBIOS Name Server 158 port numbers and requested services 158
W
WPIMs
260 CSX400 and CSX400-DC User’s Guide
POWER SUPPLY CORD
The mains cord used with this equipment must be a 2 conductor plus ground type with minimum 0.75 mm square conductors and must incorporate a standard IEC appliance coupler on one end and a mains plug on the other end which is suitable for the use and application of the product and that is approved for use in the country of application.
GERMAN:
Die Netzleitung, die mit diesem Geraet benuetzt wird, soll einen zwei Leiter mit
Erdleiter haben, wobei die Leiter mindestens 0.75 mm sind, mit einer normalen
IEC Geraetesteckdose an einem Ende und einem Geraetestecker am anderen Ende versehen sind, der fuer den Gebrauch und die Anwendung des Geraetes geeignet und der zum Benuetzen im Lande der Anwendung anerkannt ist.
SPANISH:
El cable principal de la red eléctrica utilizado con este equipo debe tener 2 conductores y 1 toma de tierra con un mínimo de 0.75 mm2 cada uno y necesita tener un aparato de acoplamiento standard IEC en un extremo y un enchufe para el cable principal de la red eléctrica en el otro extremo, lo cual sea adecuado para el uso y applicación del producto y lo cual sea aprobado para uso en el pais de applicación.
FRENCH:
Le cordon d' alimentation reliant cet appareil au secteur doit obligatoirement avoir deux fils conducteurs de 0.75 mm2 minimum et un fil de terre. It doit également
être équipé du côté appareil d'une fiche agrée IEC et du côte secteur, d'une prise adaptée à l'usage du produit et aux normes du pays où l'appareil est utilisé.

Public link updated
The public link to your chat has been updated.
Advertisement