Veilux VP-58CND12X is a 12X Mini Speed Dome Camera with various surveillance functions such as auto scan, tour, preset, pattern, sector, privacy masking, and alarm input. It features 12X optical zoom with 16X digital zoom, 360° endless rotation, and intelligent pan/tilt controlling. The camera is suitable for indoor and outdoor applications with its IP 66 ingress protection rating.
Advertisement
Advertisement
Veilux Model # VP-5 8 CND12X User Manual
MINI SPEED DOME CAMERA
12X Mini Speed Dome Camera
Instruction Manual
Website: www.Veilux.net Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
CONTENTS
Warnings & Caution ---------------------------------------------------------------------------------------- 3
What ’s in the Box? ----------------------------------------------------------------------------------------- 3
General Features --------------------------------------------------------------------------------------------- 4
Names of Each Part ---------------------------------------------------------------------------------------- 5
Installation ---------------------------------------------------------------------------------------------------- 6
A. Connections ---------------------------------------------------------------------------------- 6
B. Ceiling Mount Type ------------------------------------------------------------------------ 7
C. Embedded Mount Type ---------------------------------------------------------------------- 8
D. Pipe Mount Type ------------------------------------------------------------------------------ 10
E. Gooseneck Mount Type --------------------------------------------------------------------- 12
F. Wall Mount Type ------------------------------------------------------------------------------ 13
G. Corner Mount Type --------------------------------------------------------------------------- 15
H. Pole Mount Type ------------------------------------------------------------------------------ 17
Quick Operating Keys ------------------------------------------------------------------------------------- 18
Diagnostic ------------------------------------------------------------------------------------------------------ 20
OSD Menu Setting-------------------------------------------------------------------------------------------- 21
A. OSD Menu Table ------------------------------------------------------------------------------ 21
B. DOME SET ------------------------------------------------------------------------------------- 22
C. CAMERA SET --------------------------------------------------------------------------------- 27
D. PRESET ---------------------------------------------------------------------------------------- 29
E. AUTO SCAN SET----------------------------------------------------------------------------- 30
F. TOUR SET ------------------------------------------------------------------------------------- 31
G. PRIVACY SET --------------------------------------------------------------------------------- 32
H. PATTERN SET -------------------------------------------------------------------------------- 33
I. ALARM SET------------------------------------------------------------------------------------ 34
J. SECTOR SET --------------------------------------------------------------------------------- 35
DIP Switch Setting ------------------------------------------------------------------------------------------ 36
A. Factory Default setting --------------------------------------------------------------------- 36
B. ID Setting (1-ON, 0-OFF)(1->10)---------------------------------------------------------- 36
C. Protocol Setting ------------------------------------------------------------------------------- 37
D. Baud Rate Setting ---------------------------------------------------------------------------- 37
E. 485 Terminations ------------------------------------------------------------------------------ 37
Trouble Shooting --------------------------------------------------------------------------------------------- 38
Specification ------------------------------------------------------------------------------------------------- - 39
Dimension -------------------------------------------------------------------------------------------------- 40
Website: www.Veilux.net
Phone # 1-800-510-6528
2
Veilux Model # VP-5 8 CND12X User Manual
WARNINGS & CAUTION
If you fail to read this information and handle the product incorrectly, death or
serious injury may occur.
The unit should be installed by the trained personnel
Switch off immediately if the product emits smoke or abnormal heat.
Never install the product in area exposed to water, oil or gas.
Never install the product on a ceiling that cannot hold its weight.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Never install the product in extreme high or low temperature.
Ensure that the product is not subjected to strong impacts and vibration
Never expose the camera to direct sunlight
Never touch the front glass of the product.
This symbol is intended to alert the user to the presence of un-insulated
“dangerous voltage ” within the product ’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Warning
Never manually move the pan/tilt assembly. Serious and permanent
damage will occur
What ’s in the Box ?
1. Camera
2. Screws ( Ø4x16 screw 5EA )
3. Terminal block 5pin 2EA (DC Type)
4. Terminal block 5pin 1EA , 6pin 1EA
(AC 12V Type)
5. Manual
6. Screw Cap (1 EA)
Website: www.Veilux.net
Phone # 1-800-510-6528
3
Veilux Model # VP-5 8 CND12X User Manual
GENERAL FEATURES
12X Zoom Mini Speed Dome
12X Optical Zoom with 16X digital zoom
±0.05° dome system accuracy with full
micro step
With 0.05° positional accuracy, the camera provides excellent sensitive and delicate control. This is achieved by full micro step motors and twin gear system
360° Endless Rotation
12X mini speed dome is capable of endless rotation of 360 degrees
Compensation function: preset position
The function provides absolute preset position even in difficult applications where vibration and strong winds may otherwise affect dome performance.
Over 200°/Sec Preset Speed
The 360° full pan function moves through a maximum of
200°/sec., enabling you to quickly pinpoint the spot you want to watch. Tilt speed is also driven at 200°/sec on preset seek.
Polarity Protection of Power (DC12V)
This protection function prevents damage to the domes power board if the dc supply is connected with incorrect polarity.
Filter changeable True Day/Night
Top quality images are assured under day and night conditions due to the true day / night camera with IR cut filter. Low light sensitivity is further increased by the cameras digital slow shutter.
Indoor / Outdoor applications
The domes small size and construction to IP 66 ingress protection rating make it ideal for internal or external applications.
Quick Operation Keys
This camera provides quick function keys to allow control by most keyboards and DVRs that have Pelco protocol support.
Various Surveillance Functions
Auto Scan repeats pan and tilt between two preset positions with different speed and dwell time.
8 Group Tour up to 8 Programmable Group tours are available with each group is consisting of up to 60 preset steps with different speed and dwell times along with 16 character titling.
165 Preset positions up to 165 programmable preset positions are available with 16 character title.
8 Patterns up to 8 programmable user-defined patters are available with 16 character title. Each can be up to
50 seconds long, giving a total of 400 seconds.
8 Sectors up to 8 programmable user-defined sectors are available with 16 character titling.
4 Privacy Masking Zones up to 4 programmable user-defined privacy masking zones are available.
4 Alarm input up to 4 alarms can be wired to the dome head and can activate presets, tours, or patterns.
150°/S – Manual speed
The dome provides up to 150°/sec of manual speed and is also adjustable from 100°/sec to 150°/sec in 10°/sec increments.
1/4 ” Sony Super HAD CCD
Equipped with Sony Super HAD CCD technology, the camera provides excellent sensitivity and low smear levels.
Intelligent Pan/Tilt Controlling
Intelligent Pan/Tilt function is continually increases or decreases pan and tilt speeds in proportion to zoom.
Dome Housing
The elegantly designed aluminum body and Poly
Carbonate dome cover provide a very solid product for a wide range of applications.
Password Protection
It is possible to password protect all dome settings to prevent unauthorized changes.
Website: www.Veilux.net
4
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
NAMES OF EACH PART
FIG. 1
1. Surface Mount Adaptor
2. Cap Screw (PT3/4, 1EA)
3. Dip Switch
4. Terminal Block
5. Main body
Website: www.Veilux.net
5
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
A. CONNECTIONS
A-1
1. Loose the screws on the domes cover and remove it from the base.
(Screws won ’t be removed)
2. Loosen the screws which connect mount cover and Main base and separate dome cover from the main base. (These are captive screws that do not remove)
3. Connect power to Power and GND.
4. Connect video to video and GND.
5. Connect communication cable to RS-485 connectors.
6. Connect alarm common cables to GND. Connect the alarm input cables to their relevant terminal (1-4) Alarm polarity can be programmed as N/O or N/C
● Do not over tighten screws. This can cause damage.
■ 12VDC type
■ 24VAC type
FIG. 2
Website: www.Veilux.net
Phone # 1-800-510-6528
6
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
B. CEILING MOUNT TYPE
FIG. 4
FIG. 3
1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to install. (FIG. 3)
Caution ) Be sure to use seal tape for 3/4" cap screw to prevent a water leakage.
2. When you use pipe, please note the standard size of pipe. (FIG.4)
Caution ) Be sure to use seal tape for pipe screw to prevent a water leakage.
3. Re-assemble the dome.
FIG. 5
Website: www.Veilux.net
Phone # 1-800-510-6528
7
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
C. EMBEDDED MOUNT TYPE
Contents
■ Embedded mount bracket 1ea
■ Decoration cover 1ea
■ Screw – M3.0 x 6 5ea
■ Holder 3ea
■ Safety wire 2ea
■ Screw - Ø4.0 x 16 1ea
SAFETY WIRE HOLE
LOCK LEVER
LOCK LEVER
LOCK LEVER
FIG. 6
M3.0 SCREW
CAMERA
Website: www.Veilux.net
SAFETY WIRE (25cm)
M3 SCREW
HOLDER
DECORATION COVER
FIG. 8
8
SUSPENSION
SAFETY WIRE (150cm)
LOCK LEVER
FIG. 7
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
1. Make a hole, 190mm, on the ceiling. (FIG. 6)
2. Hook the safety wire over suspension and safety wire hold of embedded mount bracket.
Fold the lock levers and insert the bracket into the hole.
You can fix the lock lever by driving screws. (FIG. 7)
3. Fix the decoration cover on the rear of camera by holder screws (M3.0) (FIG. 8)
4. Drive the screw (M4.0) to fix safety wire of camera and hook the safety wire over safety wire hold of embedded mount bracket. (FIG. 9)
5. Install the camera by inserting cover lock and twisting it clockwise. (FIG. 10)
6. Fix the decoration cover by screw (Ø4.0x16) (FIG. 10)
FIG. 9
Website: www.Veilux.net
FIG. 10
9
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
D. PIPE MOUNT TYPE
Contents
■ Pipe mount bracket 1ea
■ Screw – M4.0 x 8 4ea
■ Rubber 1ea
■ Set anchor bolt (W5/16) 4ea
SCREW M4x8 (4ea)
BRACKET
(RUBBER BOTTOM VIEW)
RUBBER
BOTTOM COVER
FIG. 11
1. As above FIG.11, assemble rubber and bracket on the bottom of camera.
2. After finishing assembly, it will be shown as below. (FIG.12)
FIG. 12
Website: www.Veilux.net
Phone # 1-800-510-6528
10
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
3. If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter
4 holes by drill like FIG. 13 (Depth 37mm)
4. Install SET ANCHOR BOLT on the holes.
5. As shown on FIG.15, after assembling mini PTZ and bottom cover assembly, drive the pipe mount bracket and fix. (FIG.15)
Caution ) Be sure to use seal tape for pipe screw to prevent a water leakage.
FIG. 13
Website: www.Veilux.net
PIPE MOUNT BRACKET
THREAD SEAL TAPE
BOTTOM COVER ASSEMBLY
<the cable into the ceiling>
<the cable out of the ceiling>
FIG. 14
MINI SPEED DOME CAMERA
FIG. 15
Phone # 1-800-510-6528
11
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
E.
GOOSENECK MOUNT TYPE
Contents
■ Gooseneck mount bracket 1ea
■ Set anchor bolt (W5/16) 4ea
■
■
Rubber 1ea
Screw M4x8 4ea
<the cable into the ceiling> <the cable out of the ceiling>
FIG. 16
1. If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter
4 holes by drill like FIG.16 (Depth 37mm)
2. Install SET ANCHOR BOLT on the holes.
3. As shown on FIG.17, after assembling mini PTZ and bottom cover assembly, drive the gooseneck mount bracket and fix. (FIG.17)
Caution ) Be sure to use seal tape for pipe screw to prevent a water leakage.
GOOSENECK MOUNT BRACKET
THREAD SEAL TAPE.
BOTTOM COVER ASSEMBLY
Website: www.Veilux.net
MINI SPEED DOME CAMERA
FIG. 17
Phone # 1-800-510-6528
12
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
F. WALL MOUNT TYPE
Contents
■ Wall mount bracket 1ea
■ Hexagon Socket head cap screw M4.0 x16 4ea
■ Hexagon wrench 3mm L Type 1ea
■ Set Anchor Bolt (W5/16) 4ea
1. If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter
4 holes by drill like FIG. 1 (Depth 37mm) (FIG.18)
2. Install SET ANCHOR BOLT on the holes.
3. To install Wall Mount Bracket
Tip> Select a ceiling board strong enough to hold 4 times the total weight of the camera
(Weight combined camera: approx.5kg)
FIG. 18
FIG. 19
<the cable into the ceiling> <the cable out of the ceiling>
Website: www.Veilux.net
Phone # 1-800-510-6528
13
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
4. Assemble a wall mount bracket and camera by Hexagon socket head cap screws
(M4.0X16) (FIG. 20)
HEXAGON SOCKET HEAD CAP
SCREW M4.0x16 4EA
Website: www.Veilux.net
FIG. 20
14
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
G. CORNER MOUNT TYPE
Contents
■ Corner mount adaptor 1ea ■ Set Anchor Bolt (W5/16) 4ea ■ M10 Bolt & Nut 4ea
1. First mark the positions of holes placing the corner mount bracket. (FIG. 21)
2. Make 12.5mm diameter 4 holes by drill. (Depth 37mm)
3. Install SET ANCHOR BOLT on the holes.
4. Fix the wanted bracket on the corner mount bracket with 4 ea of M10 BOLT before you install the corner mount bracket. (FIG. 22)
5. Screw the set anchor bolt of the bracket by nut on the wall. (FIG. 23) mark the positions of holes
FIG. 21
M10.0 BOLT
GOOSENECK MOUNT
BRACKET
GOOSENECK MOUNT
BRACKET
CORNER MOUNT
BRACKET
CORNER MOUNT
BRACKET
FIG. 22
FIG. 23
Website: www.Veilux.net
15
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
6. After driving a bottom cover assembly to gooseneck mount bracket, as shown on FIG 23, assemble mini PTZ with bottom cover assembly. (FIG. 24)
Caution ) Be sure to use seal tape for pipe screw to prevent a water leakage.
GOOSENECK MOUNT
BRACKET
CORNER BRACKET
THREAD SEAL TAPE
BOTTOM COVER ASSEMBLY
MINI SPEED DOME CAMERA
FIG. 24
Website: www.Veilux.net
16
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
INSTALLATION
H. POLE MOUNT TYPE
Contents
■ Pole mount adaptor 1ea ■ Band Clamp 2ea ■ M10 Bolt & Nut 4ea
1. Fix the wanted bracket on the pole mount bracket with 4 ea of M10 BOLT before you install the pole mount bracket. (FIG. 25)
2. Tie the bracket with SUS BAND tightly. (FIG. 26)
3. As shown FIG. 26 after installing a wall mount bracket, fix a camera on the wall mount bracket.
(FIG. 27)
FIG. 25
M10 BOLT
WALL MOUNT BRACKET POLE MOUNT BRACKET
SUS BAND
FIG. 26
HEXAGON SOCKET HEAD CAP SCREW
M4.0x16 4ea
Website: www.Veilux.net
FIG. 27
17
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
QUICK OPERATING KEYS
The dome supports Pelco-D/P, SAMSUNG and VICON protocols.
The dome may be used with any controller or DVR etc that supports the Pelco D and Pelco
P protocols.
The default setting of the dome is Pelco D / P with 2400 bps (baud rate).
[PELCO D/P, SAMSUNG PROTOCOLS]
The comprehensive feature set of the dome is available from Pelco compatible controllers via quick operation keys as defined below.
1-64 + preset and 100~200 + preset are used for normal user presets.
Presets 65-99 + are reserved for special functions.
For example, to enter OSD MENU, press the button 95 + Call
<Quick Operation Key Table 1, Pelco D/P, SAMSUNG>
Number Note
1 ~ 64, 100~200 +Call PRESET
65 + Call PRESET STATUS
Execute Preset 1 ~ 64
Display Preset Status
66 +Call
67 +Call
71~78 +Call
81~88 +Call
AUTO SCAN
AUTO FLIP
Execute Auto Scan
Function
Selectable On/Off/Auto in Auto Flip function
GROUP TOUR Execute Group Tour #1 ~ #8
PATTERN Execute Pattern #1 ~ #8
91 + Call
92 + Call
93 + Call
94 + Call
95 + Call
96 + Call
97 +Call
ZERO POSITION Search For Pan / Tilt Zero Position
FREEZE
BLC MODE
D/N MODE
Select Freezing of current image
Selectable On/Off in BLC function
OSD MAIN MENU To enter OSD Main Menu
FOCUS ADJUST Focus adjustment
ALARM
Selectable Day/Night Mode (Auto/Day/Night Mode)
Selectable Enable/Disable all Alarms
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Menu
Tilt Up / Down
Pan Left / Right
Focus Near
Focus Far
Zoom Tele
Zoom Wide
Sub menu cursor moves up / down
Enter to the sub menu or status change or decrement
Using for Enter key when user select YES or NO
Using for function changing keys when set coordinate
Status cursor to the right
Status cursor to the left
Function
●
●
65 + Call : “Preset Status” is displayed, to remove this screen, press Focus Near button.
92 + Call : This feature freezes the current live image during tour, auto scan or pattern operation. W hen you press 92 + Call button, the image freezes but the camera is still
● working as per operation such as tour, pattern or auto scan. To return to normal images, press
92 + Call button again.
This feature is operated by preset number but not included in OSD main menu.
If a controller asks for an unsupported feature “Not available” is displayed on the monitor.
Website: www.Veilux.net
18
Phone # 1-800-510-6528
Veilux Model # VP-56CND12X User Manual
QUICK OPERATING KEYS
[VICON PROTOCOL]
If user wants to choose Vicon Protocol, the user may change the dip switch first.
(Refer to Page #36 DIP SWITCH SETTING - PROTOCOL)
Baud Rate: 4800 (Vicon default)
The operation system is almost same as Pelco D/P protocols but some special features are different way as noted below ’
<Quick Operation Key Table 2: VICON>
Number
1 ~ 79 +Call
80~87 +Call
88~89 +Call
90 + Call
90 + Call
91 + Call
92 + Call
93 + Call
Note
PRESET Execute Preset 1 ~ 79
Function
GROUP TOUR Execute Group Tour #1 ~ #8
PATTERN Execute Pattern #1 ~ #2
Focus Mode Set Focus Mode Toggle to Auto or Manual
Pan/Tilt Lockout PAN/TILT Lock or Unlock setting
ZERO POSITION Search For Pan / Tilt Zero Position
ALARM Selectable Enable/Disable all Alarms
BLC MODE Selectable On/Off in BLC function
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Menu
Tilt Up / Down
Pan Left / Right
A/P
A/I
Zoom Tele
Zoom Wide
Sub menu cursor moves up / down
Using for Enter key when user select YES or NO
Using for function changing keys when set coordinate
Status cursor to the right
Status cursor to the left
Function
Enter to the sub menu or status change or decrement
Website: www.Veilux.net
19
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
DIAGNOSTIC
Whenever the dome is powered on, a standard diagnostic is operated.
The following messages are displayed on the monitor.
CAMERA ID : 001
BAUD RATE : 2400 BPS
WAITING………
PAN ORIGIN TEST OK
TILT ORIGIN
TX CONNECTION
TEST OK
TEST OK
CAMERA COMM
A. Pan Origin Test
TEST OK
Zero point of Pan is located during the Panning test.
B. Tilt Origin Test
Zero point of Tilt is located during the Tilt test.
C. TX connection Test
The TX connection test looks for commands from a controller to the dome. If no commands are detected the test will exit after 60 seconds.
During the 60 seconds, the camera must receive a signal from the controller or DVR, so please operate the controller during this phase. As soon as the dome detects a command “OK” will be displayed and the test will move on to the next step.
If the Tx connection test fails check the RS 485 wiring.
D. Camera Comm. Test
Camera communication is also checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK, “NOW EEPROM CHECKING” and “ALL DATA INITIALIZING” is displayed and the camera is ready to operate.
Website: www.Veilux.net
20
Phone # 1-800-510-6528
MAIN MENU
DOME SETUP
CAMERA SET
AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
SECTOR
EXIT
DOME SET
CAMERA ID □□□□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 100°/S
AUTO FLIP : OFF
ZOOM SPEED
ALARM
: FAST
: DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
CAMERA SET
MIRROR : OFF/ON
D ZOOM : OFF/ON
WB MODE : AWB MODE
PIC FLIP : OFF/ON
BLC : OFF/ON
D/N MODE : AUTO
DSS MODE : OFF/ON
EXIT
PRESET SET
PRESET NO: 001
PRESET ID: PRESET01 □□□□□□□□□
PAN:XXX.X.XX.X TILT:XXX.X.XX.X
SAVE
EXIT
AUTO SCAN SET
START ANGLE : XXX.X.XX.X
END ANGLE : XXX.X.XX.X
DIRECTION : CW
ENDLESS
SPEED
DWELL TIME : 03
SAVE AND EXIT
EXIT
: OFF/ON
: QUICK
TOUR SET
TOUR NO. : 01
TOUR TITLE : TOUR01 □□□□□□
TOUR STEP : 01
PRESET NO : 01
DWELL TIME : 3
SPEED : 200°/S
SAVE AND EXIT
EXIT
PRIVACY SET
PRIVACY NO. : 01
DISPLAY : ON/OFF
ACTION : MOVE/ADJUST
SAVE
EXIT
PATTERN SET
PATT NO. : 01
PATT TITLE PATTERN01 □□□
DATA FILL : 100%
SAVE
EXIT
ALARM SET
ALARM NO. : 01
ALARM INPUT : OFF
ALARM ACT : 01
SAVE
EXIT
SECTOR SET
SECTOR NO : 01
SECTOR ID : SECTOR01 □□□
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
DOME SET
SYSTEM LOCK : OFF
[PASS WORD]
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
OSD DISPLAY
CAMERA ID: OFF/ON
PRESET ID: OFF/ON
SECTOR ID: OFF ON
COORDINATE:ON/OFF
[PREVIOUS PAGE]
[SYSTEM STATUS]
PROTOCOL : PELCO D,P
BAUD RATE: 2400BPS
FIRMWARE VER.:2.00
UPGRADED DATE: 06.28,06
CAMERA MODULE: SDM100
[PREVIOUS PAGE]
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT
[REVIOUS PAGE]
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
To enter OSD Menu, press the button 95 + Call.
MAIN MENU
DOME SETUP
CAMERA SET
PRESET
AUTO SCAN
TOUR
PRIVICY
PATTERN
ALARM
SECTOR
EXIT
* Use “ up down” to move the position and “ left right” to make selection
B. Dome Setup
In order to enter Dome setup, select right direction when the cursor is on dome setup.
DOME SET
CAMERA ID : CAM1
RECOVER : OFF
MANUAL SPEED : 100°/S
AUTO FLIP
ZOOM SPEED
ALARM
LANGUAGE
[NEXT PAGE]
SAVE AND EXIT
EXIT
: OFF
: FAST
: DISABLE
: ENGLISH
DEFAULT SETTING
B-1. DOME SET - CAMERA ID
To set camera name, and select a title of up to 16 characters using left or right direction keys or joystick.
Press ZOOM TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction
(Space displays when appears)
Website: www.Veilux.net
Phone # 1-800-510-6528
22
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
B-2. DOME SET - RECOVER
This feature allows the dome to revert to a specific programmed action when the dome has not received a command for the recovery timer period.
Actions can be Auto scan, group tour and pattern. The recovery time can be programmed from
15 second to 90 seconds. The default setting is OFF.
B-3. DOME SET - MANUAL SPEED
The manual speed of Pan/Tilt is selectable from 100°/sec up to 150°/sec.
The default setting is 100°/sec
B-4. DOME SET - AUTO FLIP
Auto Flip enables the dome to automatically do a 180° turn when the tilt bottom point is reached.
The default setting is OFF. This function can be recalled by pushing 67+ Call button.
B-5. DOME SET - ZOOM SPEED
Zoom speeds are selectable as FAST or SLOW mode. The default setting is FAST.
B-6. DOME SET - ALARM
You must enable the alarms for them to operate. The default setting is DISABLED.
This function can be recalled by pushing 97 + Call button.
B-7. DOME SET - LANGUAGE
Multiple languages are selectable (English, German, Dutch, Danish, French)
The default setting is ENGLISH.
B-8. DOME SET - [NEXT PAGE]
DOME SET
SYSTEM LOCK: : OFF
[PASS WORD]
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
DEFAULT SETTING
B-8-1. DOME SET - [NEXT PAGE] - SYSTEM LOCK
All stored dome settings can be password protected to prevent unauthorized changes.
In order to enter [PASS WORD] page, the system lock status must firstly be set as ON.
The default setting is OFF.
Website: www.Veilux.net
23
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
B-8-2. DOME SET - [NEXT PAGE] - [PASSWORD]
To enter this page to set a password, move joystick or pan key in the right direction.
The password must be set by preset number from 001 to 255 (Default 99)
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***
Enter any number from 001~255 on the password blank area and again for confirmation on blank area. Then “CONFIRMED” is displayed on the monitor and the menu will go back to the previous page automatically.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CONFIRMED
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***NOT CORRECT
<CONFIRMED> <CANCELLED>
If you press an incorrect number between PASSWORD and CONFIRM, “NOT CORRECT” is displayed on the monitor.
* When a password has been set, the operator must enter the correct password in order to enter OSD MAIN MENU, or to change any of the domes configuration data
* If you set a password you must ensure that it does not get lost. If this happens the dome
must be returned for workshop repair
B-8-3. DOME SET - [NEXT PAGE] - [OSD DISPLAY]
The camera ID setting defines whether the camera OSD display is displayed or switched off.
OSD DISPLAY
CAMERA ID
PRESET ID
SECTOR ID
COORDINATE
: OFF
: OFF
: OFF
: ON
[PREVIOUS PAGE]
DEFAULT SETTING
Website: www.Veilux.net
24
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
B-8-4. DOME SET - [NEXT PAGE] - [SYSTEM STATUS]
This page shows the information of this camera.
SYSTEM STATUS
PROTOCOL
BAUD RATE
: PELCO D, P
: 2400 BPS
FIRMWARE VER. : X.XX
UPGRADED DATE : YY.MM.DD
CAMERA MODULE : XXXXXXXX
[PREVIOUS PAGE]
DEFAULT SETTING
- Protocol and baud rate are shown according to the dip switch setting
(Refer to page 36, 37)
- Firmware version and upgraded date will be changed if the dome has been upgraded.
- The camera module type is stated as follows.
SAMSUNG 1 2X ZOOM CAMERA MODULE.
B-8-5. DOME SET - [NEXT PAGE] - [INITIALIZATION]
To clear the current settings select the item that you wish to reset back to factory defaults.
INITIALIZATION
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT]
[PREVIOUS PAGE]
- To clear the memorized data, move the joystick or pan right key until the cursor is on the required item.
TOUR CLEAR
TOUR CLEAR
ARE YOU SURE? YES NO
Website: www.Veilux.net
25
Phone # 1-800-510-6528
Veilux Model # VP58 CND12X User Manual
OSD MENU SETTING
Press FOCUS NEAR button when the cursor is at YES in order to clear memorized data.
Then each item such as tour, preset, and sector will flicker for about 2~3 seconds. After this process, the menu is returned to the previous page.
* Use the above method for [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR],
[PATTERN CLEAR], [TOUR CLEAR].
LOAD OPTIMIZED DEFAULT
ALL DATA INITIALIZING
ARE YOU SURE? YES NO
- To clear all data and return to factory defaults, move the joystick right or press the pan right key to when the cursor is at [LOAD OPTIMIZED DEFAULT] to enter the next page.
- Move joystick or the pan right keys so that the cursor is over YES, then press the
FOCUS NEAR button.
“ALL DATA INITIALIZING” is then displayed for about 5~7 seconds and then the menu is returned to the previous page automatically.
B-9. DOME SET - [NEXT PAGE] - SAVE AND EXIT
To save the memorized data and escape this page, move the joystick right or press the pan right key when cursor is at SAVE AND EXIT.
B-10. DOME SET - [NEXT PAGE] - EXIT
In order to escape this page, move the joystick right or press the pan right key when the cursor is at EXIT
Website: www.Veilux.net
26
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
C. CAMERA SET
CAMERA SET
FLICKER
MIRROR
APERTURE
D ZOOM
WB MODE
PIC FLIP
BLC
D/N MODE
DSS MODE
EXIT
: OFF
: OFF
: 10
: OFF
: AWB MODE
: OFF
: OFF
: AUTO
: OFF
DEFAULT SETTING
C-1. CAMERA SET - FLICKERLESS
The flicker less feature has options of 50Hz and 60Hz.
The default setting is OFF (NTSC: 60Hz / PAL: 50Hz). The flicker less mode only needs to be set when there is a mismatch between the power frequency and camera sync rate.
The default setting is OFF.
C-2. CAMERA SET - MIRROR
This feature literally swaps the image left and right as if looking into a mirror.
The default setting is OFF.
C-3. CAMERA SET - APERTURE
Aperture correction enhances the picture details and sharpness by increasing the gain of the caemra. Increade the value to sharpen the image, decrease to soften it The default seeting is 10.
(the aperture level is from 01 ~ 15)
C-4. CAMERA SET - D ZOOM
If neabled digital zoom is applied when the zoom lens has reached its maximum optical zoom in capability The default setting is OFF.
C-5. CAMERA SET - WB MODE
White balance functions has 4 modes and may need to be changed depending on the situation.
● AW B Mode – 3,200°K to 6, 000°K (Default)
●
●
●
Indoor – up to 3,200°K
Outdoor – up to 5,800°K
ATW Mode - 2,000°K to 10, 000°K
Website: www.Veilux.net
27
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
C-6. CAMERA SET - PIC FLIP
The picture flip feature swps the top and bottom of the image, literally inverting it.
The default setting is OFF.
C-7. CAMERA SET - BLC (Back Light Compensation)
The default setting is OFF and BLC modes can be OFF/ON.
● OFF – Backlight compensation is not activated.
● ON – Back light compensation is activated.
This function can be recalled by pushing 93 + Call button.
C-8. CAMERA SET - D/N MODE
The dome camera can operate in day /night mode and will switch depending on lighting conditions. Alternatively it can be forced into color only mode.
The default setting is AUTO MODE.
This function can be recalled by pushing 94 + Call button.
C-9. CAMERA SET - DSS MODE (DIGITAL SLOW SHUTTER)
If digital slow shutter is enabled the exposure time of the camera is increased, this allowing more light to be collected and improving low light response. This setting should not be enabled if the dome is touring at night or fast moving objects are likely to be in the scene as smearing is also increased.
The default setting is OFF.
C-10. CAMERA SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net
28
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
D. PRESET SET
To enter PRESET SET, move joystick to the right direction.
PRESET SET
PRESET NO :001
PRESET ID :PRESET001-------
PAN :XXX.XX TILT : XXX.XX
SAVE
EXIT
DEFAULT SETTING
D-1. PRESET - PRESET NO.
Up to 165 preset positions are available. Use the joystick or pan left/right keys to select the number.
D-2. PRESET - PRESET ID
To create preset titles use the joystick or pan left/right keys to navigate the menu.
The ZOOM TELE button moves to the next character from left to right and ZOOM WIDE button moves to the next character from right to left (Space displays when appears)
D-3. PRESET - PAN: XXX.X TILT: XX.X
Press FOCUS FAR button in order to set preset position then, use the joystick or pan left/right keys to the position where memorized preset number .is needed. Then press FOCUS FAR button again after setting a preset location.
D-4. PRESET - SAVE
Move the joystick right or press the pan right key when the cursor is at SAVE and then the cursor will be located on Preset ID for the continuous preset No. setting.
D-5. PRESET - EXIT
To escape this page, move the joystick right or press the pan right button.
Website: www.Veilux.net
29
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
E. AUTO SCAN SET
* 66 + Call button is working as AUTO SCAN after setting.
AUTO SCAN SET
START ANGLE : XXX.X.XX.X
END ANGLE : XXX.X.XX.X
DIRECTION
ENDLESS
SPEED
: CW
: OFF
: 10°/S
DWELL TIME
SAVE AND EXIT
EXIT
: 03
DEFAULT SETTING
E-1. AUTO SCAN - START ANGLE
To set the start position, press FOCUS FAR button then move the dome to the required start position. Press FOCUS FAR button again is to escape.
E-2. AUTO SCAN - END ANGLE
To set the end position, press FOCUS FAR button then move the dome to the required end position. Press FOCUS FAR button again is to escape.
E-3. AUTO SCAN - DIRECTION
Auto Scan directions are available as CW or CCW.
● CW: Clock wise direction (Default)
● CCW: Count Clock Wise Direction.
E-4. AUTO SCAN - ENDLESS
Auto Scan can be set to endless rotation by enabling the endless option.
The default setting is OFF.
E-5. AUTO SCAN - SPEED
Auto scan speed can be programmed from 05°/S up to 35°/S. The default setting is 10°/S.
E-6. AUTO SCAN - DWELL TIME
The dwell time at the start and end points can be programmed from 1 second to 30 seconds.
The default setting is 03 seconds.
E-7. AUTO SCAN - SAVE AND EXIT
To save the memorized data and escape this page, move the joystick right or press the pan right key when the cursor is at SAVE AND EXIT.
E-8. AUTO SCAN - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net
Phone # 1-800-510-6528
30
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
F. TOUR SET
8 Programmable tours can be set and each tour can have up to 64 preset steps.
After setting up the tours the 71~78 + Call buttons launch group tours # 1~8
TOUR SET
TOUR NO
TOUR TITLE
TOUR STEP
PRESET NO.
DWELL TIME
SPEED
SAVE
EXIT
: 01
: TOUR01
: 01
: 01
: 03
: 200º/S
DEFAULT SETTING
F-1. TOUR SET - TOUR NO.
Up to 8 group tours can be programmed.
F-2. TOUR SET - TOUR TITLE
To set a tour title, use the joystick left/right or pan left/right keys.
Each title can have up to 16 characters.
Press ZOOM TELE button to move the next character from left to the right and ZOOM WIDE button to move the next character from right to left (Space displays when
appears) The tour title is not displayed on the monitor and is only for the reference of user.
F-3. TOUR SET - TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed.
It is possible to match any preset # for any tour step.
F-4. TOUR SET - PRESET NO.
For each tour step it is possible to select any preset number up to 64.
The default setting is BLK
F-5. TOUR SET - DWELL TIME
Dwell time can be programmed from 1-99 seconds. The default setting is 03 seconds.
F-6. TOUR SET - SPEED
Each tour step can be set with a different speed up to 200°/S and it is selectable from 10°/S.
The default setting is 200°/S.
F-7. TOUR SET - SAVE
To save the memorized data and escape this page, move the joystick right or press the pan right key when cursor is at SAVE
F-8. TOUR SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net
Phone # 1-800-510-6528
31
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
G. PRIVACY SET
4 Privacy masking zones can be set.
PRIVACY SET
PRIVACY NO
DISPLAY
ACTION
SAVE
EXIT
: 01
: OFF
: MOVE
DEFAULT SETTING
G-1. PRIVACY SET - PRIVACY NO.
Up to 4 privacy masking zones can be set.
G-2. PRIVACY SET - DISPLAY.
Move the joystick right or left or press pan right/left to set ON in order to show the selectable block in the center of the monitor. This block appears as a translucent square with blue color when set ON. The default setting is OFF.
G-3. PRIVACY SET - ACTION (MOVE / ADJUST)
To set the blocking area, press FOCUS FAR button when MOVE MODE is displayed.
Then use the joystick or pan keys to the user defined area in order to set the blocking area.
Then press FOCUS FAR button again to escape from MOVE MODE.
To adjust the size of the blocking area, move the joystick or use the pan keys when the cursor is on ACTION. After it has changed to ADJUST MODE, press FOCUS FAR button in order to adjust the size of the blocking area. The size of the blocking area can be adjusted by using joystick up/down or left right – or the pan and tilt keys. After adjusting the size of the blocking area, press FOCUS FAR button to escape the ADJUST mode.
● ADJUST : You can change the masking size by using the joystick or pan keys
● MOVE : You can move the masking area by using the joystick or pan keys (Default)
G-4. PRIVACY SET - SAVE
After setting the privacy masking zone, to save the data, move the joystick right or pan right key when the cursor is on SAVE. After saving the data, the cursor moves to PRIVACY NO.2 automatically to prepare for the next privacy masking zone.
G-5. PRIVACY SET - EXIT
To escape this page, move the joystick right.
Website: www.Veilux.net
32
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
H. PATTERN SET
8 programmable patterns are available, each with a programmable title.
After setting up each pattern # 1~8, 81~88+ preset buttons will recall Patterns # 1~8.
PATTERN SET
PATT NO : 01
PATT TITLE: PATTERN01 □□□□□□□
DATA FILL : 0%
SAVE
EXIT
DEFAULT SETTING
H-1. PATTERN SET - PATT NO.
Up to 8 programmable user-defined patterns are available.
H-2. PATTERN SET - PATT TITLE
To set PATTERN TITLE move Joystick left/right or use the pan keys.
Press ZOOM TELE button moves to the next character from the left / right and ZOOM WIDE button moves to the next character from the right / left (Space displays when appears)
The pattern title is not displayed on the monitor, but only for the reference of the user.
H-3. PATTERN SET - DATA FILL
To memorize a pattern, press FOCUS FAR button in order to start the process.
The progress is shown as % filled. Press FOCUS FAR button again in order to escape.
H-4. PATTERN SET - SAVE
To save the memorized pattern data, move the joystick right or press the pan right key when the cursor is on SAVE. Then the cursor moves to the PATT NO.02 in order to prepare for the next pattern.
H-5. PATTERN SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website: www.Veilux.net
33
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
I. ALARM SET
4 Alarm inputs are available and each input can activate presets, group tours or patterns.
ALARM SET
ALARM NO : 01
ALARM INPUT : OFF
ALARM ACT
SAVE
: 001
EXIT
DEFAULT SETTING
I-1. ALARM SET - ALARM NO.
Up to 4 alarms are selectable by using joystick right or pressing the pan right key when the cursor is on ALARM NO.
I-2. ALARM SET - ALARM INPUT
Alarm inputs can be programmed as NC (Normally Close) or NO (Normally Open)
The default setting is OFF.
I-3. ALARM SET - ALARM ACT
Active alarms can trigger modes such as presets, Group tours 1-8, and Patterns 1-8.
Use the joystick or pan keys to select any preset number, group tour no. or pattern no.
I-4. ALARM SET - SAVE
After setting up the alarm features, to save the data move the joystick right or press the pan right key when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2 automatically to prepare for the next alarm.
I-5. ALARM SET - EXIT
To escape this page, move the joystick right or press the pan right key.
* Before activating Alarms, you must set ALARM ENABLE at DOME SET – ALARM – ENABLE
(Refer to page 23)
Website: www.Veilux.net
34
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
OSD MENU SETTING
J. SECTOR SET
Up to 8 programmable sectors are available, each with a 16 character title.
This feature allows the various areas of the domes 360° rotation to be given logical titles.
When the dome is moved the relevant title for each area is displayed as the dome passes through the area.
SECTOR SET
SECTOR NO : 01
SECTOR ID: SECTOR01 □□□□□□□□
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
Start Position
End Position
DEFAULT SETTING
J-1. SECTOR SET - SECTOR NO.
Up to 8 programmable sectors are available.
J-2. SECTOR SET - SECTOR ID
To set a SECTOR ID, use the joystick or pan left/right keys.
Press ZOOM TELE button to move to the next character from left to right and ZOOM WIDE button to move to the next character from right to left (Space displays when appears)
J-3. SECTOR SET - SECTOR START
To set a SECTOR START position, press FOCUS FAR button then move the joystick or pan keys to set the position. Press FOCUS FAR button again to escape.
J-4. SECTOR SET - SECTOR END
To set a SECTOR END position, press FOCUS FAR button then move the joystick or pan keys to set the position. To press FOCUS FAR button again to escape.
J-5. SECTOR SET - SAVE
After setting the SECTOR positions, to save the data move the joystick right or press the pan right key when the cursor is on SAVE. After saving the data, the cursor moves to SECTOR NO.2 automatically to prepare for the next SECTOR.
J-6. SECTOR SET - EXIT
To escape this page, move the joystick right or press the pan right key.
K. EXIT
To escape OSD Main Menu, move joystick to the right or left direction then this camera is
Ready to operate.
Website: www.Veilux.net
Phone # 1-800-510-6528
35
Veilux Model # VP-5 8 CND12X User Manual
DIP SWITCH SETTING
A. FACTORY DEFAULT SETTING
The dome cameras RS 485 address is set using switches 1-6 of DIP SW 1, refer to the table below...
Open the camera case to set ID using DIP SW 1.
* Factory default: Camera ID = 1, PELCO-D Baud Rate: 2400bps
Termination
Baud rate
Protocol
ID Set
B. ID SETTING (1-ON, 0-OFF) (110)
DIP SW
100000XXXX
010000XXXX
110000XXXX
001000XXXX
101000XXXX
011000XXXX
111000XXXX
000100XXXX
100100XXXX
010100XXXX
110100XXXX
001100XXXX
101100XXXX
011100XXXX
111100XXXX
000010XXXX
100010XXXX
010010XXXX
110010XXXX
001010XXXX
101010XXXX
011010XXXX
ID VALUE
9
10
11
12
13
14
15
16
17
18
19
20
21
5
6
7
8
1
2
3
4
22
DIP SW
111010XXXX
000110XXXX
100110XXXX
010110XXXX
110110XXXX
001110XXXX
101110XXXX
011110XXXX
111110XXXX
000001XXXX
100001XXXX
010001XXXX
110001XXXX
001001XXXX
101001XXXX
011001XXXX
111001XXXX
000101XXXX
100101XXXX
010101XXXX
110101XXXX
001101XXXX
ID VALUE
31
32
33
34
35
36
37
38
27
28
29
30
23
24
25
26
39
40
41
42
43
44
DIP SW
101101XXXX
011101XXXX
111101XXXX
100011XXXX
100011XXXX
010011XXXX
110011XXXX
001011XXXX
101011XXXX
011011XXXX
111011XXXX
000111XXXX
100111XXXX
010111XXXX
110111XXXX
001111XXXX
101111XXXX
011111XXXX
111111XXXX
ID VALUE
53
54
55
56
57
58
59
60
49
50
51
52
45
46
47
48
61
62
63
Website: www.Veilux.net
36
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
DIP SWITCH SETTING
C. PROTOCOL SETTING
7 th
~8 th dip switches are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P (Auto detection)
DIP SW1- 7
OFF
ON
OFF
ON
DIP SW1- 8
OFF
OFF
ON
ON
D. BAUD RATE SETTING
The 9 th
Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Pelco-D or Pelco-P
VICON
SAMSUNG
Factory Default: 2400bps. (If user selects Vicon protocol, then Baud rate is automatically set as 4800bps.
DIP SW1 9 th
OFF
ON
BAUD RATE
2400bps(Default)
4800bps(VICON)
9600bps
E. 485 TERMINATIONS
10 th
Dip Switch is used for 100 Ω termination.
Set on 10 th
Dip Switch only for the last looped camera from the controller.
Even in case of only one camera, set on 10 th
Dip Switch of the camera.
TERMINATION
SW-ON
CAM 1 CAM 2 CAM n-1 CAM n
Website: www.Veilux.net
37
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
TROUBLE SHOTING
If you have trouble setting up or operating the camera, refer to the following.
PROBLEM SOLUTION
No operation
Check if the power supply is DC12V.
Check if RS-485 communication cable is connected correctly.
Check camera ID setting.
Check the RS 485 termination.
No picture
Check if all the cables are connected correctly.
Check if the monitor is adjusted correctly.
Check for video locally at the dome.
Dark screen
Abnormal camera operation
Check video termination and monitor settings
Check if PSU voltage level at the dome
Check the RS 485 termination.
Website: www.Veilux.net
38
Phone # 1-800-510-6528
Veilux Model # VP-5 8 CND12X User Manual
SPECIFICATIONS
MODEL 12X Mini Speed Dome Camera
PAN /TILT
FUNCTIONS
POWER
OTHERS
CAMERA
MODULE
Pan Rotation Angle
Pan Speed
Tilt Rotation Angle
Manual
Preset
Tilt Speed
Manual
Preset
Presets
Privacy Masking Zones
Pattern
Sector
Group Scanning
Auto scan
Password Protection
Alarm Input
Alarm Actions
Auto Flip
OSD Menu
Communication
Protocol
Power Consumption
12V DC
Power Supply
Construction
Motor Type
Operating Temperature
Certifications
Image Sensor
Total Image Pixels
Number Of Effective
Pixels
Horizontal resolution
NTSC
PAL
NTSC
PAL
Lens
Optical
Digital
Day & Night (ICR)
Digital Slow Shutter
Min. illumination
Normal mode
Night mode
Luminance S/N Ratio
Video Output
BLC
Flicker less
NTSC
PAL
WHITE BALANCE
DIMENSIONS
360º Endless
Max 150º /sec
Max 200º /sec
0º ~ 90º
Max 150º /sec
Max 150º /sec
165 positions with a 16-character label available for each position
4 Programmable privacy masking zones
8 Programmable pattern tour
8 Programmable sectors
Max.8 Programmable group tours (each one consisting of up to
60 preset steps with different steps)
Programmable Auto scan
Yes
4 alarms OFF/NC/NO (with various programmable states)
Activate preset, tour and patterns
ON / OFF
Multiple Languages on screen
RS-485
Pelco D/P, VICON, SAMSUNG
750mA, 10W MAX (1.3A, 16W MAX with Heater)
12V DC 750mA (1.3A with Heater)
Anti-vandal bubble (Poly carbonate), Body (Aluminum)
Stepper Motor
-10ºC ~ 50ºC (-40ºC ~60ºC with heater)
IP66,CE,FCC
1/4" Sony Super HAD CCD
811(H) * 508(V) 410K
795(H) * 596(V) 470K
768(H) * 494(V) 380K
752(H) * 582(V) 440K
580 TV Lines/ B/W 660 TV Lines
12x Optical Zoom f=3.94 ~ 46.05mm (F1.67~1.88)
12x (192x with optical)
Auto/ Day/ Night
ON / OFF
0.2Lux / F1.6 (Color: 50IRE)
0.04Lux / F1.6 (B/W : IRC ON)
More than 502B
Composite video output 75 Ω Terminated
ON / OFF
ON / OFF (1/100)
ON / OFF (1/120)
ATW/AWC/INDOOR/OUTDOOR
Website: www.Veilux.net
Phone # 1-800-510-6528
39
Veilux Model # VP-5 8 CND12X User Manual
UNITS : mm
Website: www.Veilux.net
40
Phone # 1-800-510-6528

Download