Airwell BS 12 DCI User manual

Airwell BS 12 DCI User manual
airwell.com
AIRWELL
France
ACE Marketing SAS
1 bis, avenue du 8 mai 1945
Saint Quentin en Yvelines
78284 Guyancourt cedex
France
[email protected]
Spain
IBER ELCO SA
Ciencas 71-78, Modulo 5
Poligono Pedrosa
08 902 L’Hospitalet de Llobregat
Spain
[email protected]
Greece
ACE KLIMA HELLAS M.E.P.E.
98A, Vass. Sofias Ave.
11528 Athens
Greece
Italy
ITELCO CLIMA Srl
Via XXV Aprile, 29
20030 Barlassina (MI)
Italy
[email protected]
Your approved
ACE MARKETING SAS - 1 bis, av. du 8 mai 1945 - Saint-Quentin-en-Yvelines
F - 78284 Guyancourt Cedex
Fax: +33 (0) 1 39 44 65 17 - Tel.: +33 (0) 1 39 44 78 00 - e-mail: [email protected]
www.airwell.com
Russia
AIRWELL CIS
000 “Airwell CIS”
Bolshaya Sadovaya Str.
8 build.1 - 103379, Moscow
Russia
distributor
Catalogue Europe 2007 - Airwell Air Conditioning & Heating
Germany
ACE Klimatechnik GmbH
Berner Straße 43
D-60437 Franckfurt/Main
Germany
[email protected]
CRTI AN 01/2007 ACE MARKETING RCS VERSAILLES B 421 305 996 - Specifications subject to change without notice - Pictures non contractual -
United Kingdom
AIRWELL UK
St Thomas Business Centre
St Thomas Street
Newcastle upon Tyne
NE1 4LE
United Kingdom
[email protected]
- Printed in E.U.
Subsidiaries in Europe
RESIDENTIAL
/
TERTIARY
/
INDUSTRIAL
CATALOGUE EUROPE 2007
AIR CONDITIONING & HEATING
THE POWER OF A GROUP,
THE STRENGTH OF A NETWORK
LIN G ON
OO
LY
C
P
AT PUM
HE
R407C Fluid
All AIRWELL
products bear
the CE mark
Founded in 1947, Airwell is becoming a leader in air conditioning in France and in the rest of Europe.
Since its creation, the Airwell network has continually expanded to be ranked as one of the major
players in air conditioning across Europe, and worldwide.
Airwell has always been involved in designing, manufacturing and marketing air conditioning
systems adapted the market's most demanding requirements. This entails total commitment,
dedicated entirely to innovation, quality and service.
As part of its continuous product development programme, Airwell currently offers a broad range
of products to meet the specific requirement of all market sectors.
R410A Fluid
GENERAL NOTES: All values are specified for a 230 V supply voltage.
Nominal cooling capacity: International conditions: 27°C/19°C (wet bulb) - outside air temperature 35°C/24°C
(wet bulb) (Standards NF EN 255.2 - NF EN 814.2).
Nominal heating capacity: International conditions: 20°C/12°C (wet bulb) - outside air temperature 7°C/6°C (wet bulb)
(Standards NF EN 255.2 - NF EN 814.2).
Acoustic levels: Global acoustic pressure in dB(A) (1m comfort range, 4 m industrial and chilled water) under nominal
conditions: outdoor unit in an open area against a reflective background - indoor unit: installation in an average sized
room (PV - 0.5 s reverberation) or acoustic capacity depending on models.
CHILLED WATER
1) Water chillers
Nominal cooling capacity: watez inlet / outlet: 12°C / 7°C - outside air temperature: 35°C.
2) Terminal units
Nominal conditions: air 27°C / 19°C wet bulb (nominal air flow) - Chilled water: 7°C / 12°C
The fuse values and the between-unit (Split-System) link cable specifications are stated for basic units
without accessories.
5 PRODUCTION SITES WORLDWIDE,
IN PERFECT SYNERGY
With highly efficient manufacturing resources benefiting from state-of-the-art
manufacturing techniques, the group has 5 manufacturing plants worldwide with a total
production capacity of 2,000,000 units. Our research & development and manufacturing
systems are designed around each site's production specialisation.
Tillières (France)
Manufacture of industrial appliances for
world markets. Aeraulics, thermodynamics
and fluid mechanics R & D Centre.
Surface area: 110,000 m2.
Annual production:
180,000 units.
Dong-Guan (China)
Production and R & D Centre
for electronic components
at Group level.
Surface area: 15,000 m2.
Annual production:
5 million items (PCB, RC, IAQ…).
Barlassina (Italy)
Manufacture of large capacity air conditioning and
chilled water production appliances up to 1,000 kW
as well as convector fans.
Surface area: 50,000 m2.
Annual production: 30,000 units.
Shenzhen (China)
Production of low capacity
residential and semi-industrial
appliances.
Surface area: 100,000 m2.
Annual production:
1,000,000 units.
Pons (France)
Manufacture of medium capacity
chilled water production
appliances, chilled water
terminals, convector fan
and air treatment units
Surface area: 55,000 m2.
Annual production:
72,000 units.
1
SUMMARY
General
information
p. 6
DC INVERTER
RANGE
Wall mounted
PHOENIX/ FLORIDA DCI
3.4 to 8.5 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
16
DAKOTA WDI _ _ _ _ _ _ _ _ _
2.5 to 5.3 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
18
3.2 to 8.4 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
20
3.4 to 9.0 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
22
4.3 to 8.8 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
24
DUO/TRIO/QUATTRO DCI
6.2 to 9.5 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
28
DUO/TRIO DAKOTA DCI
4.5 to 6.6 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
32
Floor/ceiling splits
SX DCI _ _ _ _ _ _ _ _ _ _ _ _ _ _
Cassettes
K & KXL DCI
_________
Ducted
BS & DLS DCI
________
Multisplits
2
R410A/R407C
COMFORT RANGE
Monoblocs
AELY/AELIA N
MAY
_____
2.9 to 3.5 kW
_____________
2.1 to 6.4 kW
4.5 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
36
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
37
Wall mounted
PHOENIX & FLORIDA N
2.2 to 10.1 kW
2.1 to 11.1 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
38
ALASKA WN/WAF
__
2.3 to 5.1 kW
2.3 to 5.3 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
40
____
2.5 to 3.3 kW
2.8 to 3.6 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
42
2.6 to 8.5 kW
2.7 to 8.6 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
44
10.1 to 13.0 kW
11.0 to 13.9 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
46
LOUISIANA XLF
Floor/ceiling splits
SX N
S
_____________
________________
VAR _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.5 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
48
CAO _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.3 to 4.7 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
49
SX SP
1.9 to 5.5 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
50
5.2 kW to 8.4 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
52
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
54
____________
SX TELECOM
______
CCE _ _ _ _ _ _ _ _ _ _ _ _ _ _
15 kW
3
R410A/R407C
COMFORT RANGE (continuation)
Cassettes
KN LV & KXL N
MD
_______
2.8 to 12.3 kW
________________
9.1 to 12.6 kW
3.0 to 13.2 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
56
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
58
Ducted
BS/DLS
CD
_____________
_________________
3.4 to 12.4 kW
3.4 to 13.1 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
60
14.5 to 16.9 kW
14.3 to 17.2 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
62
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
64
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
66
Water cooled units
GCAO N _ _ _ _ _ _ _ _ _ _ _ _ _
2.4 to 9.1 kW
Multisplits
DUO R410A _ _ _ _ _ _ _ _ _ _
5.7 to 5.9 kW
5.3 to 14.2 kW
INDUSTRIAL
RANGE
Vertical cabinet units
XAR _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.7 to 55 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
70
XAO
8 to 45.7 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
72
________________
Packaged split system
DK/DN
_____________
HA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4
12 to 83 kW
12.4 to 83.8 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
74
10.1 to 27.8 kW
10.1 to 26.5 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
76
CHILLED WATER
& HEAT PUMP
RANGE
Fan-convectors
2 Pipes [email protected]
__
1.1 to 13.9 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
80
4 Pipes [email protected]
__
1.1 to 14 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
82
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
84
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
86
REGULATION [email protected]
Cassettes
2 & 4 pipes KOG
___
2.2 to 10.6 kW
Ducted/Wall mounted
VHF OG _ _ _ _ _ _ _ _ _ _ _
3.3 to 11.9 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
88
XLM OG _ _ _ _ _ _ _ _ _ _ _
1.8 to 4.6 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
89
Air/water chillers
MQL/MQH _ _ _ _ _ _ _ _ _ _
4.5 to 16.5 kW
5 to 18.8 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
90
21.5 to 75 kW
24 to 87.4 kW
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
92
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _p.
94
[email protected]
AQL/AQH
_________
Air/water heat pump
CWP
_____________
7.6 to 33.7 kW
9 to 40.1 kW
5
NEW 2007
PHOENIX
Wall mounted
PNX DCI & PNX
PNX DCI 9/12
PNX 7/9/12/14
> Phoenix, you don’t have
to choose between
design and technology
ALASKA
Wall mounted
WN
WN 7/9/12
> Sobriety and discretion
LOUISIANA
XLF
Wall mounted
XLF 9/12
> Perfect blowing with
4 air diffusion directions
6
AELY
Mobiles
AELY 9/12
> Just plug it
and benefit
immediatly
from a fresh
new air.
GCAO N
Floor/ceiling splits
GCAO N 7 to 30
> Ideal solution for
premises where
it’s impossible
to install an
outdoor unit!
S
Floor/ceiling splits
S 110 & S130
> Multi-position architecture
for low wall and ceiling
mounting
CHILLED WATER & HEAT PUMP UNITS
2 & 4 pipes
[email protected]
AQL/AQH
CWP
7
DC INVERTER TECHNOLGY
Flexibility and comfort of use, quickly reaching the desired set temperature, silent running
and optimal ambient temperature control in addition to energy savings are all features that make
the DC INVERTER range truly exceptional.
As a genuine concentrate of state-of-the-art technologies, the DCI range has been designed
to provide a very high comfort level for users and ease of fitting for installers.
ENERGY SAVINGS
Compared with a traditional fixed speed system, DCI technology represents energy savings of 30%
(classe A).
By avoiding compressor start up and stoppage phases, DC INVERTER technology enables the system to
run continuously while modulated the compressor output in relation to the room's set temperature point.
By accurately detecting the heating or cooling loads required, the system avoids frequent output changes
and thereby guarantees efficient and economic operation.
SILENT RUNNING
Compared with traditional fixed speed compressors, DC INVERTER compressors allow for progressive
start-ups and continuous operation with a significant reduction in noise levels and vibrations that
guarantees silent running.
QUICKLY REACHING THE SET TEMPERATURE POINT
The compressor's variable rotational speed allows for optimal, quick and efficient output modulation,
providing for more accurate control of the ambient temperature: to the nearest 1/2 degree.
Ambient
temperature
Ambient
temperature
COOLING
HEATING
Set
temperature
DC Inverter model
Fixed speed model
DC Inverter model
Set
temperature
Fixed speed model
Time
Time
Time to reach set
temperature
Time to reach set
temperature
HEATING MODE OPERATION DOWN TO
The latest DC INVERTER technology, combined with the use of R410A "green" fluid, allow for optimal
efficiency (Class A energy label) and exceptional performance with the capability of operating in Heating
mode at outdoor temperatures down to -15 °C.
8
MULTI-FUNCTIONS REMOTE CONTROLS
at the forefront of ergonomic design
> RCW2 model
BASIC FUNCTIONS
Compatible with products from the Comfort and Industrial ranges.
Heating / Cooling electronic regulation.
Automatic ventilation or 3 fixed speeds ventilation.
Night time slow running.
Dehumidification.
PROGRAMMING
Managing up to 15 zones (32 units) with individual unit time
programming and temperature setting.
7 day programmable timer with 2 daily setting ranges.
2 TIMERS CENTRALISED CONTROL
Easy functions duplication for quick programming.
“Master/Slave” function.
Time delayed start up of air treatment units (quick installation).
Permanent “I feel” function (single installation).
> RC4 model
> RC5 model
> RC7 model
With their compact and ergonomically design, Airwell infrared controls offer excellent user comfort. Combining modern design
with high technology, the remote controls, with a range of up to 8 m, offer a host of functions and great simplicity of use to make
our users' day-to-day life so much easier.
With these remote controls, users can select the operating mode (Heating-Cooling-Dehumidification), choose the set
temperature point, ventilation speeds or air sweeping and also programme a host of advanced functions such as:
PROGRAMMING
NIGHT RUNNING
The microprocessor automatically manages air conditioning for
maximum user comfort. The Timer enables the unit to be
programmed to switch itself on and off as and when required,
thereby contributing to optimal energy consumption.
This function adapts the temperature for ideal night time rest
conditions for the user and contributes to energy savings.
Both in Heating and in Cooling mode it is possible to programme
3 set temperatures automatically. Energy consumption reductions
amount to 7 % per degree, representing considerable savings.
Leaving home:
Programming and putting
the unit on standby.
Programmed
unit start-up.
“I FEEL” FUNCTION
Returning home:
Ambient temperature
at desired level.
This innovation from the Airwell R&D department enables the
temperature measurement point to be transferred for improved
temperature control.
9
AIRWELL,
TECHNOLOGY
IN HARMONY WITH
THE ENVIRONMENT
ECOLOGICALLY FRIENDLY REFRIGERANT FLUIDS
Airwell's primary objective is to design and offer air conditioning systems that
meet both the highest standards of environmental protection and users'
legitimate expectations in terms of comfort and wellbeing.
For Airwell, innovation has to be linked tightly to a respect for the environment
and must include stringent requirements in terms of quality levels. This ongoing
concern governs all our actions and involves all our human and technology
resources.
In accordance with this principle and with European Directives, in its appliances,
Airwell uses ecological refrigerant fluids of the HFC type (R410A & R407C) that
do not harm the planet's ozone layer.
Moreover, with a constant care for participating in preserving the environment,
Airwell designs and markets high efficiency products that reduce CO2 emissions
into the atmosphere and minimise our contribution to global warming.
10
ENERGY LABEL
Indication of annual energy consumption
Based on a standard model, this annual consumption is calculated by
multiplying the total capacity by an average running time of 500 hours per
annum in Cooling mode and under full load.
Air-conditioner
Energy
Manufacturer
Outside unit
Unside unit
GC 9 DCI R410
ST PNX 9 DCI
More efficient
COOLING CAPACITY
The refrigerating capacity is defined as the cooling capacity in kW of an
appliance, running in Cooling mode under full load.
A
A
B
C
D
EER OR ENERGY EFFICIENCY RATIO
This is the ratio between the refrigerating capacity and the amount of electricity
consumed to attain it. In other words, the higher the EER, the better the energy
efficiency.
E
F
G
ENERGY EFFICIENCY CATEGORIES*
IN COOLING MODE
A
EER > 3.2
B 3.2 > EER > 3.0
C 3.0 > EER > 2.8
D 2.8 > EER > 2.6
E 2.6 > EER > 2.4
F 2.4 > EER > 2.2
G 2.2 > EER
Less efficient
* Only for splits and multisplits.
Cooling output
295
Annual energy consumption
kWh in cooling mode
(Actual consumption will depend
on how the appliance is used
and climate)
kW
Energy efficiency ratio
2.5
4.2
Ful load (the higher the better)
HEATING CAPACITY
Heating capacity is defined as the Heating capacity in kW of an appliance
running in Heating mode and under full load.
COP OR COEFFICIENT OF PERFORMANCE
This is the ratio between the Heating capacity and the quantity of electricity
consumed to attain it. In other words, the higher the COP, the better the energy
efficiency.
ENERGY EFFICIENCY CATEGORIES*
IN HEATING MODE
A
COP > 3.6
B 3.6 > COP > 3.4
C 3.4 > COP > 3.2
D 3.2 > COP > 2.8
E 2.8 > COP > 2.6
F 2.6 > COP > 2.4
G 2.4 > COP
Type
Cooling only
Cooling + Heating
Air cooled
Water cooled
Heat output
kW
Heating performance
A: higher
3.4
A
G: lower
Noise
26
(dB(A) re 1 pW)
Further information is contained
in product brochures
Norm EN 814
Air-conditioner
Energy Label Directive 2002/31/EC
The labelling classifies air conditioning systems in 7 categories (from A to G) in relation to their energy consumption. Those
appliances with the best energy efficiency are awarded an A label (Green colour arrow on the label)? those with the lowest energy
efficiency a G label (Red colour arrow ).
This label also includes a certain number of details (Brand, Model, Cooling and heating capacity, Noise level ) and allows the
user to compare the efficiency of different products.
WEEE (WASTE ELECTRICAL AND
ELECTRONIC EQUIPMENT)
On 13th August 2005, the new European Directive on Waste Electrical and Electronic Equipment (WEEE)
came into force.
The Directive's aim is to regulate the disposal of electronic waste by separating its treatment from that
of household waste.
Selective collection systems are being put in place to recover all WEEE with the view to recycling.
This Directive requires air conditioning appliance manufacturers and distributors to:
• Mark certain models marketed after 13th August 2005.
• Meet financial obligations associated with end-of-life appliance recycling.
As users of our products, and on those products covered by the Directive, you will observe a pictogram (see
illustration below) on the Maker's plate representing a "crossed-out refuse bin". This pictogram is intended to inform
the user that the appliance in question must be disposed of separately from household waste.
As part of its sustainable development policy, along with the entire profession, Airwell is committed to abiding by
this new European initiative. Our environment is precious, let's preserve it.
11
AIRCONET
Remote management of your air conditioning network
Airconet is a complete, powerful and user-friendly system providing remote management
of air conditioning installations in an overall and customised manner:
• Centralised control of a group of indoor units (building, floor…).
• Individual control in each pre-defined room and zone.
Irrespective of the type of building, by way of a simple PC connected to the Internet or to
the building's local network, Airconet provides total control of a complete air conditioning
system.
In fact, from the Airconet communication gateway connected to each of the indoor units and
depending on access rights granted, the user can regulate blown air temperatures and fan
speeds and even receive e-mail or SMS alerts regarding any system malfunctions, etc.
PRINCIPLE
The heart of the system is the Airconet communication gateway. This is a module installed on site and connected, on the
one hand to all the air conditioning units to be managed by way of an MIU (Modbus Interface Unit) and, on the other hand,
to a LAN/WEB network. In this manner, the user can connect to the communication gateway via a PC with an internet
connection.
Thanks to the Plug & play system there is no requirement for the user to install any special software as this is already loaded
in the Airconet communication gateway. Via the PC's internet navigator, it is possible to set and alter parameters such as
room temperatures and timer programming as well as to be alerted in the event of any possible malfunctions.
INSTALLATION ARCHITECTURE
e-mail
LAN / WEB
SMS
Managed site
Basic configuration: 1 Airconet communication gateway module 1 per site capable of managing up to 247 indoor units, 1 MIU 3 per indoor unit depending on the unit
type, 1 Repeater 2 for 50 MIU's or per floor.
12
BENEFITS
ADVANTAGES
Improved occupant comfort (e.g. timing a unit to start
operating before the arrival of the client/occupant).
Lower energy bills by way of energy savings derived
from overall installation control, and therefore close
control of energy consumption.
Simplified management and improved maintenance
thanks to optimal installation control and real time
interventions.
Extended equipment service life.
Completely upgradeable system.
Real time alerts by e-mail or SMS of any installation
malfunction.
User-friendly, straightforward, efficient and
autonomous interface.
Plug and Play installation, no software installation,
modem integrated in the communication Gateway.
Integrated system supervision, easy to use.
Choice of languages.
Perfect compatibility with Windows operating
systems: XP, 2000, NT, 98,…
Up to 247 units managed by a single communication
Gateway.
Very low investment.
Several user levels
LEVEL
USER
POSSIBILITIES
1
2
3
4
5
Company employee
Local normal control of an individual unit
Reception manager (hotels…)
Centralised normal control of all units
Maintenance manager
Communication gateway information verification
Technician
System definition
Supervisor/Developer
Database and parameters
CLIENT
SERVICE
Communication gateway
RANGE
Managed with all indoor units
SIZE
Managed with all sizes
PART NUMBER
AIRCONET006
MIU - Communication cards
RANGE
MODEL
SIZE
PART NUMBER
PNX DCI & FLO DCI
9-12-18-24-30
AIRCONET090
SX DCI
9-12-18
AIRCONET030
Inverter Split
BS DCI
12
AIRCONET070
K DCI
9-12-18
AIRCONET030
PNX & FLO N
30
AIRCONET080
XLF 410
9-12
Please contact us
SXN 410
9-12-15-18-24-30
AIRCONET030
KN 410
9-11-15-18
AIRCONET030
Fixed Split
KXL 410
24-30-36-45
AIRCONET110
DLS 410
18-24-30-37-44
AIRCONET070
DK/DN
all sizes
SP000000063+SP000000161
EH
all sizes
AIRCONET060
CCE 45
all sizes
AIRCONET060
Monoblocs Packaged
HA
all sizes
SP000000063+SP000000161
AQL/AQH
all sizes
SP000000063+SP000000161
NOTE 1 : Each "Airconet XXX" reference includes the communication board (MIU) as well as the connections required for connecting to the unit.
NOTE 2 : In addition to 40 MIU boards connected to the communication gateway, a REPEATER (free of charge supply) must be installed.
13
COMFORT
DC INVERTER
RANGE
NEW 2007
PHOENIX DCI (wall mounted)
TRIO DAKOTA (multisplits)
> DC Inverter :
Unrivalled wellbeing technology
The latest DC Inverter technology pushes back the limits of perfection, and guarantees the very best air conditioning
performance: Ambient temperature maintained to the nearest 1/2 degree, optimal energy efficiency, unequalled silent
running, significant energy savings, high efficiency filtration, compact outdoor units... Our overriding priority is to meet
the most stringent demands for user comfort. So be demanding and choose our exceptional Airwell DC Inverter range.
14
Comfort DC Inverter
Wall mounted p.16
Floor/ceiling p.20
Cassettes p.22
Ducted p.24
Multisplits p.28
15
Floor/Ceiling
Wall mounted
PNX/FLO DCI
Cassettes
Ducted
Multisplits
NEW
DAKOTA DCI
PNX & FLO DCI
DC Inverter Wall mounted
6 Heat Pump models : 3 400 to 8 500 W
Outdoor units GCNG 9/12/18 DCI
Indoor units PNX 9/12 DCI
Supplied with RC4 remote control
FLO 18/21/24 DCI
GC 24/30 DCI
FLO 30 DCI
> Product advantages
Perfect comfort, unequalled unobtrusiveness, great accuracy in
maintaining the desired temperature and controlling air quality.
Compatible with AIRCONET regulation.
R410A ”green” fluid.
Optimal efficiency: Class A energy label (depending on models).
Heating mode operation down to outdoor temperatures of -15° C.
Optimal temperature regulation.
Electronic regulation and programming.
AQS filtration: electrostatic filter + Ioniser.
Automatic treated air sweeping.
LCD screen (except PNX 9/12).
Fluid pre-charged at the factory for up to
20 m pipe lengths (depending on models).
EXCEPTIONAL AIR QUALITY
The Airwell ioniser produces 50,000
negative ions, as much as standing
next to a waterfall!
HIGH EFFICIENCY FILTRATION
3 filtration levels to capture
and neutralise dust, pollen, mites,
tobacco odour...
Standard filter
Active charcoal filter
Electrostatic filter
Remote control RCW2
Part number 7ACEL1212
Accessories
Mounting bracket
PNX 9 DC INV PNX 12 DC INV FLO 18 DC INV FLO 21 DC INV FLO 24 DC INV FLO 30 DC INV
Part number
7ACTL0016
7ACTL0016
7ACTL0016
-
-
-
Condensate lift pump
Part number
SAE3100
SAE3100
SAE3100
SAE3100
SAE3100
SAE3100
RCW2 connection kit
Part number
7ACEL1249
7ACEL1249
7ACEL1249
7ACEL1249
7ACEL1249
7ACEL1249
16
Comfort DC Inverter
PHOENIX DCI &
FLORIDA DCI
PNX & FLO DCI Series
PNX 9 DC INV PNX 12 DC INV FLO 18 DC INV FLO 21 DC INV FLO 24 DC INV FLO 30 DC INV
Cooling Capacity
Power Input
EER / Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -15°C
Power Input
COP / Energy label
Outdoor temperature operating limits
kW
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
3.5 (1.4-4.3)
0.99
3.5 / A
5 (1.5-6)
6 (1.5-6.7)
1.46
1.99
3.4 / A
3.01 / B
-10°/ 46° Dry Bulb
6.8 (1.5-7.5)
2.25
3.0 / B
7.8 (1.5-8.8)
2.59
3.0 / B
3.4 (1.5-5)
2.0
0.81
4.2 / A
4.3 (1.5-5.8)
2.6
1.12
3.8 / A
6 (1.5-7.6)
6.5 (1.8-7.9)
2.3
1.66
1.90
3.6 / A
3.42 / B
-15°/ 24° Dry Bulb
7.05 (1.5-8.8)
2.19
3.2 / C
8.5 (1.5-9.5)
2.65
3.2 / C
ST PNX 9 DCI
350/460/570
26/39
1
10.5
810x190x285
ST PNX 12 DCI
370/480/580
26/39
1.5
11.5
810x190x285
ST FLO 18 DCI
620/760/850
34/43
2
15
1060x210x295
ST FLO 21 DCI
620/760/900
34/45
2
15
1060x210x295
ST FLO 24 DCI
700/850/1000
38/47
2.5
15
1060x210x295
ST FLO 30 DCI
950/1100/1350
44/51
3
18.5
1200x236x340
7SP022708
7SP022709
7SP022364
7SP022329
7SP022735
7SP022333
GC 9 DCI
1780
51
Rotary DC Inverter
38
795x290x610
GC 12 DCI
1780
52
Rotary DC Inverter
38
795x290x610
GC 18 DCI
2160
53
Scroll DC Inverter
39
795x290x610
GC 21 DCI
2860
55
Scroll DC Inverter
46
846x302x690
GC 24 DCI
3600
56
Twin Rotary DC Inv.
64.5
950x412x835
GC 30 DCI
3600
56
Twin Rotary DC Inv.
66
950x412x835
7SP061420
7SP061421
7SP061422
7SP001614
7SP061677
7SP061616
Indoor
3x1.5
16
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Outdoor
3x2.5
20
4x2.5
Outdoor
3x2.5
20
4x2.5
20
10
3/8”
1/4”
20
10
3/8”
1/4”
30
10
1/2”
1/4”
30
10
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
°C
°C
m3/h
dB(A)
l/h
kg
mm
Part number
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
2.5 (1.4-3.6)
0.59
4.2 / A
m3/h
dB(A)
kg
mm
Part number
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
m
m
Inches
Inches
17
Wall mounted
PNX/FLO DCI
Floor/Ceiling
Cassettes
Ducted
Multisplits
DAKOTA DCI
WDI
DC Inverter Wall mounted
4 Heat Pump models from 2 500 to 5 300 W
Outdoor units GC 7/9/12 DCI
Indoor units WDI 7/9 DCI
Supplied with RC7
remote control
GC 18 DCI
> Product advantages
Flexibility and comfort of use.
Extended operating range.
Optimal efficiency: Class A energy label
(depending on models).
Reduced noise levels.
High efficiency filtration.
Accessories
Electronic regulation and programming.
Automatic treated air sweeping.
R410A ”green” fluid.
Optimal temperature regulation.
Heating mode operation down to outdoor
temperatures of -15° C.
WDI 7
WDI 9
WDI 12
WDI 18
Mounting bracket
Part number
7ACTL0016
7ACTL0016
7ACTL0016
7ACTL0016
Condensate lift pump
Part number
SAE3100
SAE3100
SAE3100
SAE3100
18
Comfort DC Inverter
DAKOTA WDI
DAKOTA WDI Series
WDI 7
Cooling Capacity
Power Input
EER / Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP / Energy label
Outdoor temperature operating limits
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (PV/MV/GV)
Dehumidification
Weight
Dimensions (WxDxH)
m3/h
dB(A)
kg
mm
Part number
WDI 18
2.50
0.75
3.33 / A
3.50
1.03
3.39 / A
-10°/ 46° Dry Bulb
5.00
1.56
3.20 / B
2.5
0.73
3.42 / B
2.80
0.82
3.41 / B
3.60
1.05
3.42 / B
-15°/ 24° Dry Bulb
5.30
1.55
3.41 / B
ST WDI 7
300/350/400
30/33/36
1
7
680x185x250
ST WDI 9
270/350/420
32/35/39
1
7
680x185x250
ST WDI 12
350/450/550
29/33/39
1.5
8
840x185x250
ST WDI 18
480/620/720
34/41/44
2
11
900x205x295
7SP022309
7SP022310
7SP022311
7SP022312
GC 7 RC DCI
1400
54
Rotary DC Inverter
35
760x245x545
GC 9 RC DCI
1390
54
Rotary DC Inverter
36
760x245x545
GC 12 RC DCI
1390
55
Rotary DC Inverter
37
760x245x545
GC 18 RC DCI
2160
53
Scroll DC Inverter
38
795x290x610
7SP061617
7SP061618
7SP061619
7SP061620
Indoor
12
3x1.5
4x1.5
Indoor
12
3x1.5
4x1.5
Indoor
16
3x1.5
4x1.5
Indoor
20
3x1.5
5x1.5
15
10
3/8”
1/4”
15
10
3/8”
1/4”
15
10
3/8”
1/4”
15
10
1/2”
1/4”
°C
m3/h
dB(A)
l/hr
kg
mm
WDI 12
2.20
0.66
3.33 / A
°C
Part number
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
WDI 9
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Fuse rating am
Power cable section
Electrical connections
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
A
mm2
mm2
m
m
Inches
Inches
19
Wall mounted
Floor/Ceiling
Cassettes
Ducted
Multisplits
SX DCI
SX DCI
Floor/Ceiling split units
5 Heat Pump models from 3 200 to 8 400 W
Control panel
Outdoor units GCNG 9/12/18 DCI
Indoor units SX 9/12
GC 24/30 DCI
Supplied with RC4 remote control
> Product advantages
Perfect comfort, unequalled unobtrusiveness, great
accuracy in maintaining the desired temperature and
controlling air quality.
Compatible with AIRCONET regulation (SX 24/30 DCI).
R410A ”green” fluid.
Optimal efficiency: Class A energy label
(depending on models).
Heating mode operation down to outdoor
temperatures of -15° C.
Optimal temperature regulation.
Electronic regulation and programming.
Dual automatic treat air sweeping.
Fluid pre-charged at the factory for up to 20 m pipe
lengths (depending on models).
Low wall or ceiling mounting.
Possibility of air conditioning two separate rooms
with a single unit.
Horizontal
or vertical
unit
mounting
Possibility of air
conditioning
2 separate rooms
with a single unit
Remote control RCW2
Part number 7ACEL1212
Accessories
SX 9 DC INV
SX 12 DC INV
SX 18 DC INV
SX 24 DC INV
SX 30 DC INV
7ACFH0221
Condensate lift pump
Part number
7ACFH0221
7ACFH0221
7ACFH0221
7ACFH0221
Air distribution unit
Part number
7ACVF0122
7ACVF0122
7ACVF0123
7ACVF0123
7ACVF0123
Rear panel tube cover
Part number
7ACTL0073
7ACTL0073
7ACTL0074
7ACTL0074
7ACTL0074
Mounting bracket
Part number
7ACTL0016
7ACTL0016
7ACTL0016
-
-
20
Comfort DC Inverter
CALIFORNIA
SX DCI
SX DC INVERTER Series
SX 9 DC INV
Cooling Capacity
Power Input
EER / Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -15°C
Power Input
COP / Energy label
Outdoor temperature operating limits
kW
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (PV/MV/GV)
Dehumidification
Weight
Dimensions (WxDxH)
m3/h
dB(A)
kg
mm
Part number
SX 24 DC INV
SX 30 DC INV
3.5 (1.5-4.4)
0.98
3.6 / A
5 (1.5-6.0)
1.65
3.0 / B
-10°/ 46° Dry Bulb
6.8 (1.5-7.6)
2.25
3.0 / B
7.5 (1.6-8.6)
2.49
3.0 / B
3.2 (1.5-4.5)
1.9
0.93
3.4 / B
4.2 (1.5-5.0)
2.5
1.31
3.2 / C
5.8 (1.5-7.2)
2.3
1.69
3.4 / B
-15°/ 24° Dry Bulb
7.6 (1.6-8.6)
2.1
3.6 / A
8.4 (1.9-9.8)
2.46
3.41 / B
ST SX 9 DCI
300/350/400
35/37/39
1
21
820x190x630
ST SX 12 DCI
300/400/450
38/41/45
1.5
22
820x190x630
ST SX 18 DCI
600/750/870
45/48/51
2
30
1200x190x630
ST SX 24 DCI
700/895/1020
49/53/56
2.5
32
1200X190X630
ST SX 30 DCI
700/930/1020
49/53/56
2.9
32
1200X190X630
7SP012113
7SP012114
7SP012115
7SP012151
7SP012152
GC 9 DCI
1780
51
Rotary DC Inverter
38
795x290x610
GC 12 DCI
1780
52
Rotary DC Inverter
38
795x290x610
GC 18 DCI
2160
53
Scroll DC Inverter
39
795x290x610
GC 24 DCI
3600
56
Twin Rotary DC Inverter
64.5
950x412x835
GC 30 DCI
3600
56
Twin Rotary DC Inverter
66
950x412x835
7SP061420
7SP061421
7SP061422
7SP061677
7SP061616
Indoor
3x1.5
16
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
20
10
3/8”
1/4”
20
10
3/8”
1/4”
30
10
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
°C
m3/h
dB(A)
l/h
kg
mm
SX 18 DC INV
2.5 (1.4-3.6)
0.62
4.0 / A
°C
Part number
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
SX 12 DC INV
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
m
m
Inches
Inches
21
Wall mounted
Floor/Ceiling
Cassettes
Ducted
K DCI
Multisplits
KXL DCI
K/KXL DCI
DC Inverter Cassettes
5 Heat Pump models from 3 400 to 6 300W
Outdoor units GCNG 9/12/18 DCI
Indoor units
KXL DCI 24/30
Indoor units K 9/12/18 DCI
GC 24/30 DCI
Supplied with RC4 remote control
> Les Avantages Produits
Heating mode operation down to outdoor
temperatures of -15° C.
Optimal temperature regulation.
Electronic regulation and programming.
Fluid pre-charged at the factory for up to 20 m pipe
lengths (depending on models).
Possibility of air conditioning two separate rooms
with a single unit (K DCI).
New air intake (K DCI).
High efficiency filtration.
Integrated condensate drainage lift pump.
Solid ceiling mounting frame (accessory).
Perfect comfort, unequalled unobtrusiveness, great
accuracy in maintaining the desired temperature
and controlling air quality.
Four powered air distribution flaps.
Designed for integration in suspended ceilings.
600 x 600 mm format (K DCI) / 900 x 900 mm format
(KXL DCI).
Built-in depth: 287 mm (K DCI) / 230 mm (KXL DCI).
R410A ”green” fluid.
Optimal efficiency: Class A energy label (depending
on models).
Air renewal
outside
inside
Air conditioning of an adjacent room
adjacent room
main room
Remote control RCW2
Part number 7ACEL1212
Accessories
K 9 DC INV
K 12 DC INV
K 18 DC INV
KXL 24 DC INV KXL 30 DC INV
Ceiling adapter frame
Part number
7ACVF0091
7ACVF0091
7ACVF0091
-
-
Mounting bracket
Part number
7ACTL0016
7ACTL0016
7ACTL0016
-
-
22
Comfort DC Inverter
COLORADO
K/KXL DCI
K/KXL DC INVERTER Series
K 9 DC INV
Cooling Capacity
Power Input
EER / Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -15°C
Power Input
COP / Energy label
Outdoor temperature operating limits
kW
kW
kW
K 12 DC INV
K 18 DC INV
KXL 24 DC INV KXL 30 DC INV
2.5 (1.5-3.8)
0.59
4.2 / A
3.5 (1.5-4.4)
0.95
3.7 / A
5 (1.35-6.4)
1.55
3.2 / A
-10°/ 46° Dry Bulb
7.2 (1.5-8)
2.39
3.01 / B
8 (2-8.8)
2.65
3.01 / B
3.4 (1.5-5)
2
0.91
3.7 / A
4.3 (1.5-5.5)
2.6
1.33
3.2 / C
6.3 (1.35-7.5)
2.3
1.74
3.6 / A
-15°/ 24° Dry Bulb
8 (1.5-8.8)
2.22
3.63 / A
9 (1.5-10.0)
2.46
3.46 / B
K 9 DCI
450/530/600
32/37
1
23
571x571x287
625x625x40
K 12 DCI
450/560/620
32/37
1.5
24
571x571x287
625x625x40
K 18 DCI
510/630/730
36/48
2
28
571x571x287
625x625x40
ST KXL 24 DCI
1050/1200/1300
47/52
2.5
36
840x840x230
950x950x46
ST KXL 30 DCI
1070/1170/1270
42/46
3
42
840x840x300
950x950x46
Part number frame
Included
Included
Included
7ACVF0321
7ACVF0321
Part number
7SP042088
7SP042089
7SP042090
7SP012142
7SP012147
GC 9 DCI
1780
51
Rotary DC Inverter
38
795x290x610
GC 12 DCI
1780
52
Rotary DC Inverter
38
795x290x610
GC 18 DCI
2160
53
Scroll DC Inverter
39
795x290x610
GC 24 DCI
3600
56
Twin rotary
64.5
950x412x835
GC 30 DCI
3600
56
Twin rotary
66
950x412x835
7SP061420
7SP061421
7SP061422
7SP061677
7SP061616
Indoor
3x1.5
16
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
20
10
3/8”
1/4”
20
10
3/8”
1/4”
30
10
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Dehumidification
Weight
Built in casing (LxlxH)
Frame (LxlxH)
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
°C
°C
m3/h
dB(A)
l/h
kg
mm
mm
m3/h
dB(A)
kg
mm
Part number
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
m
m
Inches
Inches
23
Wall mounted
Floor/Ceiling
Cassettes
Ducted
Multisplits
BS DCI
DLS DCI
BS/DLS DCI
DC Inverter ducted units
4 Heat Pump models from 4 300 to 8 800 W
Indoor units
DLS 18/24/30 DCI
Indoor unit
BS 12 DCI
Outdoor units GC 24/30 DCI
Supplied with RC4 remote control
Receiver
> Product advantages
Perfect comfort, unequalled unobtrusiveness, great accuracy in
maintaining the desired temperature and controlling air quality.
Compatible with AIRCONET regulation.
Designed for integration in suspended ceilings.
Low noise levels.
Low built—in height: BS = 245 mm; DLS = 260 mm.
R410A ”green” fluid.
Optimal efficiency: Class A energy label.
Heating mode operation down to outdoor temperatures of -15° C.
Optimal temperature regulation.
Electronic regulation and programming.
Fluid pre-charged at the factory for up to 20 m pipe
lengths. (depending on models).
Possibility of air conditioning two separate rooms with a single unit.
New air intake (BS DCI).
High efficiency filtration.
Air distribution / air intake plenums (BS DCI accessory).
Accessories
BS 12 DC INV
Ducted air distribution
BS 12 + multi-zone air distribution ducts connection
+ air intake ducts
connection plenum
+ air intake cassette
plenum under the unit
(Grilles and ducts – on-site supply)
DLS 18 DC INV
DLS 24 DC INV
DLS 30 DC INV
N°1 cassette air intake plenum kit
Part number
7ACVF0075
-
-
-
N°2 duct connection plenum kit
Part number
7ACVF0073
-
-
-
Air supply plenum
Part number
-
7ACVF0317
7ACVF0317
7ACVF0317
Mounting bracket
Part number
7ACTL0016
7ACTL0016
-
-
24
Non-contractual photos
INDOOR UNITS INSTALLATION
Comfort DC Inverter
BS/DLS DCI
BS/DLS DC INVERTER Series
BS 12 DC INV
Cooling Capacity
Power Input
EER / Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -15°C
Power Input
COP / Energy label
Outdoor temperature operating limits
kW
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (PV/MV/GV)
Static pressure
Dehumidification
Weight
Built in casing (LxlxH)
m3/h
dB(A)
kg
mm
Part number
DLS 30 DC INV
5 (1.6-6.4)
1.55
3.2 / A
6.8 (1.6-8)
2.26
3.0 / B
-10°/ 46° Dry Bulb
7.5 (1.6-9.0)
2.48
3.0 / B
4.3 (1.6-5.5)
2.6
1.34
3.2 / C
6 (1.4-7.7)
1.6
3.75 / A
7.6 (1.8-8.8)
2.08
3.7 / A
-15°/ 24° Dry Bulb
8.8 (1.5-10.5)
2.44
3.6 / A
ST BS 12 DC INV
530/700/830
35/38/42
25
1.3
30
860x245x680
ST DLS 18 DC INV
730/920/1170
34/37/42
25/60
1
29
790x256x749
ST DLS 24 DC INV
935/1150/1320
33/43/47
25/60
1.5
29
790x256x749
ST DLS 30 DC INV
935/1150/1320
40/44/48
25/80
2.5
31
790x256x749
7SP022345
7SP022403
7SP022405
7SP022406
GC 12 DCI
1780
52
Rotary DC Inverter
38
795x290x610
GC 18 DCI
2160
53
Scroll DC Inverter
39
795x290x610
GC 24 DCI
3600
56
Twin Rotary DC Inverter
64.5
950x412x835
GC 30 DCI
3600
56
Twin Rotary DC Inverter
66
950x412x835
7SP061421
7SP061422
7SP061677
7SP061616
Indoor
3x1.5
16
4x1.5
Indoor
3x2.5
20
4x2.5
Outdoor
3x2.5
20
4x2.5
Outdoor
3x2.5
20
4x2.5
20
10
3/8”
1/4”
30
15
1/2”
1/4”
50
25
5/8”
3/8”
50
25
5/8”
3/8”
°C
m3/h
dB(A)
Pa
l/h
kg
mm
DLS 24 DC INV
3.5 (1.5-4.6)
0.96
3.7 / A
°C
Part number
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
DLS 18 DC INV
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
m
m
Inches
Inches
25
Wall mounted
Floor/Ceiling
Cassettes
Ducted
BS DCI
Multisplits
DLS DCI
MAIN ADVANTAGES OF DLS DC INVERTER MODEL
> “V” battery
The Airwell units are the
most compact existing
on the market; this is
due to the innovating
design of its battery.
> Minimum
height
Its reduced height
(300 mm max) enables
it to be perfectly
integrated in any type
of false ceiling.
> ABS fan
High Technology
The only ducted unit
using a high-technology
plastic fan thus
guaranteeing:
- good air flow rate
- excellent static pressure available
- extremely low operating sound level.
> Float valve
Safety element.
Avoids condensate
stagnation.
Models 18-24-30
Reduced height: 260 mm
> Electrical
connection
panel
(remoted up to 1.8 mm)
Safety elements
designed to avoid
possible condensate
drainage problems.
> Condensate
drain pan
The condensate drain
pan collects fluids from
the heat exchanger
(these fluids are due
to the condensation
occurring in the
exchanger).
26
> Refrigerant
tubing
connections
Installed in the top part
of the device to facilitate
installation.
> Filter
Removable filter with
simple and easy
maintenance.
Comfort DC Inverter
DLS DCI
> Long lengths of refrigerant
tubing connections between
internal and external units
Models 24 and 30: 50 metres of connection
possible with an elevation difference of
25 metres.
Installation facilitated and reduced costs.
Possibility of installing outdoor units on
a terrace to avoid altering the nature
of building front walls.
> Air intake
Designed for perfect
ventilation.
25 m
> Accessories
Option: air flow plenum
for models 18, 21, 24
and 30.
This plenum connects the
unit to a duct network
(ideal for installing
circular duct networks on
the rectangular blowing
part of the unit), and can be configured
in several manners.
> Remote controls
Well-being at your fingertips
Elevation difference of 25 m.
RC4
Electronic control for the entire range (included).
Multi-function electronic control system consisting of an IR receiver and a remote control.
The entire range benefits from the following functions: on/off; cold/hot/ventilation; time programming;
room temperature indication; I feel function; automatic programming; night slowdown function.
27
Wall mounted
Floor/Ceiling
Cassettes
Ducted
Multisplits
DUO/TRIO
QUATTRO DCI
Multisplits
combinations chart
DUO/TRIO
DAKOTA DCI
DUO/TRIO/QUATTRO DCI
DCI Multisplits
3 Heat Pump models from 6 200 to 9 500 W
> Product advantages
Outdoor units compatible avec with
DC Inverter indoor units.
R410A ”green” fluid.
DC Inverter Twin Rotary compressor
(depending on models).
Compact outdoor units.
Class A energy label.
Heating mode operation down to
outdoor temperatures of -15° C.
Set temperature point reached rapidly.
Silent running.
Up to 70 m pipe lengths.
TRIO 72/QUATTRO 80 DCI
DUO 50 DCI
Compatibility guide
DCI Wall mounted
Cooling Capacity
Heating capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Weight
Dimensions
Part number
PNX 9 DCI
kW
kW
m3/h
dB(A)
kg
mm
DCI Floor/Ceiling splits
Cooling Capacity
Heating capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/NS/HS)
Weight
Dimensions
Part number
SX 9 DCI
kW
kW
m3/h
dB(A)
kg
mm
2,5
3,2
300/350/400
35/37/39
21
820x190x630
7SP012113
kW
kW
m3/h
dB(A)
kg
mm
2,5
3,4
450/530/600
32/37
23
571x571x287
7SP042088
kW
kW
m3/h
dB(A)
Pa
kg
mm
3,50
4,30
530/700/830
35/38/42
25
30
860x245x680
7SP022345
DCI Cassettes
Cooling Capacity
Heating capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Weight
Dimensions
Part number
K 9 DCI
DCI Ducted
Cooling Capacity
Heating capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/NS/HS)
Static pressure
Weight
Dimensions
Part number
28
2,5
3,4
350/460/570
26/39
11
810x190x285
7SP022708
BS 12 DCI
PNX 12 DCI
3,50
4,30
370/480/580
26/39
11
810x190x285
7SP022709
SX 12 DCI
3,50
4,20
300/400/450
38/41/45
22
820x190x630
7SP012114
K 12 DCI
3,50
4,30
450/560/620
32/37
24
571x571x287
7SP042089
DLS 18 DCI
5
6,3
730/920/1170
34/37/42
25/60
30,5
770x260x690
7SP022403
FLO 18 DCI
5,00
6,00
620/760/850
34/43
15
1060x210x295
7SP022364
SX 18 DCI
5,00
5,80
600/750/870
45/48/51
30
1200x190x630
7SP012115
K 18 DCI
5,00
6,30
510/630/730
36/48
28
571x571x287
7SP042090
Comfort DC Inverter
DCI
MULTISPLITS
DC Inverter Multisplits Series
DUO 50 DC INV
Cooling Capacity
Power Input
EER / Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity à -15 °C ext
Power Input
COP / Energy label
Outdoor temperature operating limits
kW
kW
kW
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
7.2 (1.3-9)
2.24
3.2 / A
-10°/ 46° Dry Bulb
8 (1.4-9.2)
2.49
3.2 / A
6.2 (0.95-7.75)
3.7
1.67
3.71 / A
9 (0.95-11)
5.4
2.37
3.8 / A
-15°/ 24° Dry Bulb
9.5 (0.95-11)
5.7
2.38
4/A
2160
53
Scroll DC Inverter
43
795x290x610
3200
54
Twin Rotary DC Inverter
69
950x340x835
3200
54
Twin Rotary DC Inverter
70
950x340x835
Outdoor
3x2.5
16
2x(4x1.5)
Outdoor
3x2.5
20
3x(4x1.5)
Outdoor
3x2.5
20
4x(4x1.5)
30
25
10
5
2x1/4”
2x3/8”
50
25
15
15
3x1/4”
2x3/8” + 1x1/2”
70
25
15
15
4x1/4”
3x3/8” + 1x1/2”
7SP091110
7SP091129
7SP091130
°C
kg
mm
QUATTRO 80 DC INV
5 (1.2-6.48)
1.47
3.4 / A
°C
m3/h
dB(A)
TRIO 72 DC INV
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. lenght between per circuit
Max. height between ind. and outd. units
Max. height between indoor units
Liquid pipe diameter
Suction pipe diameter
Part number
mm2
A
mm2
m
m
m
m
Inches
Inches
1~230 V model
Accessory
Mounting bracket
DUO 50 DC INV
Part number
7ACTL0016
29
Wall mounted
Floor/Ceiling
Cassettes
Ducted
DUO/TRIO
QUATTRO DCI
Multisplits
Multisplits
combinations chart
DUO/TRIO
DAKOTA DCI
Multisplits combinations chart
DUO 50 DCI
Indoor units
combinations
9
12
9+9
9+12
12+12
Indoor units capacity (kW)
Mode
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Power Input (W)
Nom.
Min.
Max.
Nom.
Min.
Max.
Room A Room B Room C Room D capacity
capacity capacity capacity capacity capacity
3.4
3.4
0.95
4.00
1135
375
1250
2.5
2.5
1.22
3.70
680
420
980
4.2
4.2
1.0
5.2
1575
375
1760
3.5
3.5
1.2
4.4
1030
420
1275
3.1
3.1
6.2
1.3
7.1
1670
320
1960
2.5
2.5
5.0
1.4
6.0
1470
410
2100
3.1
3.5
6.6
1.3
7.4
1760
320
2020
2.5
3
5.5
1.4
6.2
1850
410
2130
3.5
3.5
6.9
1.3
7.8
1970
320
2050
3
3
6.0
1.4
6.5
2040
410
2160
COP/
EER
Energy
Label
3.00
3.68
2.67
3.40
3.71
3.40
3.75
2.97
3.50
2.94
D
A
E
A
A
A
A
B
B
C
COP/
EER
Energy
Label
4.96
3.65
4.29
3.62
3.71
3.59
3.82
3.39
3.78
3.36
3.67
3.32
3.75
3.33
3.67
3.32
3.80
3.21
3.80
3.21
3.80
3.21
3.80
3.21
3.80
3.21
3.80
3.21
3.80
3.21
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
TRIO 72 DCI
Indoor units
combinations
9
12
18
9+9
9+12
9+18
12+12
12+18
9+9+9
9+9+12
9+9+18
9+12+12
9+12+18
12+12+12
12+12+18
30
Indoor units capacity (kW)
Mode
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Power Input (W)
Nom.
Min.
Max.
Nom.
Min.
Max.
Room A Room B Room C Room D capacity
capacity capacity capacity capacity capacity
3.40
3.40
0.95
4.00
685
500
897
2.50
2.50
1.30
3.70
685
500
1025
4.30
4.30
0.95
5.20
1003
485
132
3.50
3.50
1.30
4.40
968
500
1223
6.20
6.20
1.11
7.50
1673
549
2131
5.00
5.00
1.49
5.93
1393
566
1656
3.60
3.60
7.20
1.43
9.10
1883
649
2636
2.54
2.54
5.08
1.86
6.56
1498
683
1856
3.26
4.34
7.60
1.43
9.50
2009
649
2711
2.57
3.42
5.99
1.86
7.73
1783
683
2541
3.00
6.00
9.00
1.43
10.10
2451
622
2737
2.44
4.88
7.32
1.86
9.00
2203
659
3046
4.00
4.00
8.00
1.43
9.80
2135
649
2711
3.46
3.46
6.92
1.86
9.00
2075
683
2246
3.60
5.40
9.00
1.43
10.50
2451
622
2871
2.93
4.39
7.32
1.86
9.00
2203
659
3055
3.00
3.00
3.00
9.00
2.06
10.99
237
804
3013
2.40
2.40
2.40
7.20
2.69
8.98
224
949
3049
2.70
2.70
3.60
9.00
2.06
11.00
237
804
2966
2.20
2.20
2.93
7.33
2.69
9.00
2281
949
3157
2.25
2.25
4.50
9.00
2.06
11.00
237
773
2826
1.83
1.83
3.66
7.32
2.69
9.00
2278
962
3097
2.45
3.27
3.27
8.99
2.06
11.00
2367
804
2938
1.99
2.66
2.66
7.31
2.69
9.00
2275
949
3097
2.07
2.76
4.14
8.98
2.14
11.00
2365
773
2752
1.69
2.25
3.37
7.31
2.69
9.00
2275
962
3061
3.00
3.00
3.00
9.00
2.06
11.00
237
804
2845
2.44
2.44
2.44
7.32
2.69
9.00
2278
990
3085
2.57
2.57
3.85
8.99
2.14
11.00
2367
773
2696
2.09
2.09
3.13
7.30
2.69
9.00
2272
962
3086
QUATTRO 80 DCI
Indoor units
combinations
9
12
18
9+9
9+12
9+18
12+12
12+18
9+9+9
9+9+12
9+9+18
9+12+12
9+12+18
12+12+12
12+12+18
9+9+9+9
9+9+9+12
9+9+9+18
9+9+12+12
9+9+12+18
9+12+12+12
9+12+12+18
12+12+12+12
Indoor units capacity (kW)
Mode
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Power Input (W)
Nom.
Min.
Max.
Nom.
Min.
Max.
Room A Room B Room C Room D capacity
capacity capacity capacity capacity capacity
3.40
3.40
0.95
4.00
685
400
859
2.50
2.50
1.40
3.70
685
500
1025
4.30
4.30
0.95
5.20
946
388
1207
3.50
3.50
1.40
4.40
968
500
1223
6.20
6.20
1.11
7.50
1497
455
1875
5.00
5.00
1.60
5.60
1393
570
1563
3.64
3.64
7.28
1.43
8.63
1707
539
2172
2.54
2.54
5.08
2.00
6.20
1453
689
1742
3.29
4.39
7.68
1.43
9.01
1838
539
2235
2.56
3.42
5.98
2.00
7.30
1722
689
2385
3.03
6.06
9.10
1.43
9.58
2261
516
2255
2.54
5.08
7.61
2.00
8.50
221
665
2858
4.04
4.04
8.09
1.43
9.29
192
539
2235
3.45
3.45
6.90
2.10
8.80
1998
689
2921
3.80
5.70
9.50
1.43
9.96
2317
516
2366
3.15
4.72
7.87
2.10
8.80
2285
665
2876
3.03
3.03
3.03
9.10
2.06
11.00
2151
671
2621
2.40
2.40
2.40
7.19
2.90
9.00
2112
915
2938
2.85
2.85
3.80
9.50
2.06
11.00
2231
671
2891
2.36
2.36
3.15
7.87
2.90
9.00
2445
915
2899
2.38
2.38
4.75
9.50
2.06
11.00
2072
646
2883
2.00
2.00
4.01
8.01
2.90
9.00
2466
928
2851
2.59
3.45
3.45
9.48
2.06
11.00
2171
671
2874
2.17
2.90
2.90
7.97
2.90
9.00
2445
915
2851
2.19
2.92
4.38
9.48
2.14
11.00
2012
646
2731
1.87
2.50
3.74
8.11
2.90
9.00
2476
928
2821
3.16
3.16
3.16
9.49
2.06
11.00
2151
671
2857
2.69
2.69
2.69
8.07
2.90
9.00
2372
955
2841
2.71
2.71
4.06
9.48
2.14
11.00
1993
646
2671
2.31
2.31
3.47
8.10
2.90
9.00
2372
928
2802
2.38
2.38
2.38
2.38
9.50
2.69
10.97
238
657
2935
2.00
2.00
2.00
2.00
8.00
3.70
9.17
249
1091
2937
2.19
2.19
2.19
2.91
9.47
2.69
11.00
2355
657
29
1.87
1.87
1.87
2.49
8.10
3.70
9.20
2524
1091
2915
1.90
1.90
1.90
3.80
9.50
2.77
11.00
2294
646
2779
1.62
1.62
1.62
3.25
8.12
3.70
9.20
2445
1064
2882
2.03
2.03
2.71
2.71
9.49
2.69
11.00
2306
657
2857
1.74
1.74
2.32
2.32
8.11
3.70
9.20
2513
1091
2882
1.78
1.78
2.37
3.56
9.49
2.77
11.00
2195
646
2762
1.52
1.52
2.03
3.05
8.12
3.70
9.20
241
1064
2849
1.90
2.53
2.53
2.53
9.48
2.69
11.00
2269
657
2822
1.62
2.16
2.16
2.16
8.11
3.70
9.20
2501
1091
2871
1.67
2.23
2.23
3.35
9.48
2.77
11.00
2195
646
2903
1.43
1.91
1.91
2.87
8.12
3.70
9.20
241
1064
289
2.38
2.38
2.38
2.38
9.50
2.69
11.00
238
646
2796
2.03
2.03
2.03
2.03
8.12
3.70
9.20
249
1091
2838
COP/
EER
Energy
Label
4.96
3.65
4.54
3.62
4.14
3.59
4.26
3.49
4.18
3.47
4.02
3.45
4.21
3.46
4.10
3.44
4.23
3.40
4.26
3.22
4.59
3.25
4.37
3.26
4.71
3.28
4.41
3.40
4.76
3.42
3.99
3.21
4.02
3.21
4.14
3.32
4.12
3.23
4.32
3.37
4.18
3.24
4.32
3.37
3.99
3.26
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
31
Comfort DC Inverter
DCI MULTISPLITS
Wall mounted
Floor/Ceiling
Cassettes
Ducted
Multisplits
DUO/TRIO
QUATTRO DCI
Multisplits
combinations chart
DUO/TRIO
DAKOTA DCI
DUO/TRIO DAKOTA DCI
DCI Multisplits
2 Heat Pump models from 4 500 to 6 600 W
TRIO DAKOTA DCI
DUO DAKOTA DCI
> Product advantages
DUO DAKOTA DCI - Combinations 7-7 / 7-9 / 7-12 / 9-9 & 9-12.
TRIO DAKOTA DCI - Combinations 7-7-7 / 7-7-9 / 7-7-12 / 7-9-9 / 7-9-12 /
9-9-9 / 9-9-12 / 7-7 / 9-9 / 12-12.
Outdoor units compatible avec with DAKOTA DC Inverter indoor units.
R410A ”green” fluid.
DC Inverter Scroll compressor (TRIO DAKOTA DCI).
Compact outdoor units.
Class A energy label.
Heating mode operation down to outdoor temperatures of -15° C.
Set temperature point reached rapidly.
Silent running.
Compatibility guide
DCI Wall mounted
Cooling Capacity
Heating capacity
Air flow (PV/MV/GV)
Acoustic pressure to 1m (LS/NS/HS)
Weight
Dimensions
Part number
32
WDI 7
kW
kW
m3/h
dB(A)
kg
mm
WDI 9
WDI 12
2,20
2,50
300/350/400
30/33/36
7
680x185x250
2,50
2,80
270/350/420
32/35/39
7
680x185x250
3,50
3,60
350/450/550
29/33/39
8
840x185x250
7SP022309
7SP022310
7SP022311
Comfort DC Inverter
DUO/TRIO
DAKOTA DCI
NEW
DC Inverter Multisplits Series
DUO 38 DC INV
Cooling Capacity
Power Input
EER / Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP / Energy label
Outdoor temperature operating limits
kW
kW
Outdoor unit
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
3.9 (1.2-5.5)
1.14
3.42 / A
5.2 (1.0-6.5)
1.55
3.35 / A
-10°/ 46° Dry Bulb
4.5 (1.2-6.2)
1.24
3.62 / A
6.6 (1.0-7.3)
1.8
3.67 / A
-15°/ 24° Dry Bulb
°C
°C
m3/h
dB(A)
TRIO 52 DC INV
2160
53
Rotary DC Inverter
38
795x290x610
2860
56
Scroll DC Inverter
48
846x302x690
Outdoor
3x2.5
16
2 x (4x1.5)
Outdoor
3x2.5
20
3 x (4x1.5)
30
25
10
5
2 x 1/4”
2 x 3/8”
35
25
15
5
3 x 1/4”
3 x 1/2”
1~230 V model
7SP091141
7SP091142
Part number
7ACTL0016
kg
mm
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. lenght between per circuit
Max. height between ind. and outd. units
Max. height between indoor units
Liquid pipe diameter
Suction pipe diameter
Part number
mm2
A
mm2
m
m
m
m
Inches
Inches
Accessory
Mounting bracket
DUO 38 DC INV
TRIO 52 DC INV
7ACTL0018
33
NEW 2007
PHOENIX 7/9/12/14 (wall mounted)
ALASKA WN 7/9/12 (wall mounted)
LOUISIANA XLF 9/12 (wall mounted)
S 110/130 (floor/ceiling)
CD 50 (ducted)
> Comfort for everyone
At home, in offices and shops… the Comfort R410A/R407C range has been designed specially with you in mind.
Your expectations differ… So do our solutions. With both cooling only and heat pump models available, Airwell offers
you a broad range of air conditioning systems in various formats: monobloc, wall mounted, floor/ceiling, cassettes,
ducted units… We give pride of place to R410 units operating with an ecologically friendly fluid that does not harm
the ozone layer. This comprehensive Airwell Comfort R410A/R407C range with state-of-the-art technologies and
high performance, is becoming the undisputed benchmark for residential and tertiary air conditioning.
34
Comfort R410/R407
COMFORT R410/R407
RANGE
Monoblocs
p.36
Wall
mounted
p.38
Floor/Ceiling
p.44
Cassettes
p.56
Ducted
p.60
Water
cooled units
p.64
Multisplits
p.66
35
Monoblocs
Wall mounted
AELY R410A
MAY R407C
Cassettes
Floor/Ceiling
splits
Water cooled
units
Ducted
AELY/AELIA N
Multisplits
NEW
Portable units
2 Cooling Only models from 2 990 to 3 500 W
1 Heat Pump model of 4 590 W
AELY 9
AELY 12
AELIA N 14
> Product advantages
COMMANDE IR
Monobloc portable units (AELY 9/12)
or split portable units (AELIA 14).
No specific installation is required.
High deshumidification capacity.
3 fan speed.
Recycling and filtering of the air.
24h timer programmer.
“I feel” function.
Infrared remote control.
AELY / AELIA N Series
AELY 9
Cooling capacity
Power Input
EER / Label Energy
Dehumidification
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP / Label Energy
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure at 1m (LS/NS/HS)
Compressor type
Weight
Dimensions (WxDxH)
1~230 V model
AELIA N 14 IR
3.50
1.45
2.41 / B
2.2
21°/46° Dry Bulb
4.17
1.54
2.7 / A
1.80
-
-
4.59
1.39
3.3/A
kg
mm
Monobloc
280/310/350
52
Rotary
35
370x455x876
Monobloc
470/520/570
53
Rotary
45
840x450x550
Split System
356/401/433
48/50/51
38
470x360x800
kg
mm
-
-
Rotary
17
440x320x540
7MB021046
7MB021044
7MB021040
-
-
3
1.6
l/h
°C
m3/h
dB(A)
Outdoor units
Compressor type
Weight
Dimensions (WxDxH)
AELY 12
2.99
1.13
2.64 / A
1.4
Part number
Linking specifications between indoor and outdoor units
Linking pipes
Lenght
Max. height difference
36
m
m
Monoblocs
Wall mounted
AELY R410A
MAY R407C
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
unitss
Multisplits
MAY
Window units
Comfort R410/R407
5 Cooling Only models from 2 140 to 6 400 W
MAY 110
MAY 70/90
MAY 180/220
> Product advantages
Sober and unobtrusive design.
Easy to install and operate.
Built into a wall or window.
Drawer chassis.
MAY Series
MAY 70
Cooling capacity
Power Input
EER / Label Energy
kW
kW
Outdoor temperature operating limits
°C
Indoor units
Air flow - normal speed
Acoustic pressure at 1m (LS/HS)
Compressor type
Weight
Dimensions (WxDxH)
Reusable filter.
Thermostatic temperature regulation.
Angle adjustable blown air flap for even air distribution.
New outdoor air intake device.
m3/h
dB(A)
kg
mm
2.14
0.82
2.6 / C
MAY 90
2.54
1.06
2.4 / D
MAY 110
3.28
1.46
2.2 / E
MAY 180
MAY 220
5
2.25
2.2 / E
6.4
2.65
2.4 / D
21°/ 46° Dry Bulb
310
41/44
Rotary
37
450x590x350
340
42/46
Rotary
37
450x590x350
500
54/59
Rotary
47
560x610x375
800
54 / 59
Rotary
63
670x710x455
920
57 / 61
Rotary
70
670x710x455
3x1.5
6
3x1.5
6
3x1.5
8
3x1.5
10
3x1.5
16
7WT012015
7WT012016
7WT012017
7WT012028
7WT012030
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power cable section
Fuse rating am
1~230 V model
mm2
A
Part number
37
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
PHOENIX
R410A
ALASKA
R410A
LOUISIANA
R410A
Water cooled
units
Ducted
Multisplits
NEW
PNX & FLO N
Wall mounted
8 Cooling Only models from 2 223 to 10 150 W
8 Heat Pump models from 2 280 to 11 140 W
Indoor units PNX 7/9/12/14
FLO 18/24
Outdoor units GCNG 7/9/12/14
Supplied with RC4
remote control
FLO 30
GCN 18/24
GCN 36
> Product advantages
AQS version.
R410A ”green” fluid.
High efficiency filtration.
Functions displayed on LCD display (FLO 18/24/30/36).
Ioniser.
Electronic regulation and programming.
Automatic vertical treated air sweeping.
NEW: PNX & FLO N indoor units with R410A are compatible with GC AO R410A cooled water units.
Standard filter
Accessories
Active charcoal filter
PNX 7
Electrostatic filter
Ioniser
PNX 9
PNX 12
PNX 14
FLO 18 N
Mounting bracket
Part number 7ACTL0016
7ACTL0016
7ACTL0016
7ACTL0016
7ACTL0018
-
-
-
Condensate lift pump
Part number SAE3100
SAE3100
SAE3100
SAE3100
SAE3100
SAE3100
SAE3100
-
All seasons kit
Part number 7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
-
NOTE : Important, installation of an all seasons kit only allows for operation in cooling mode.
38
FLO 24 N
FLO 30 N
FLO 36 N
PHOENIX PNX &
FLORIDA FLO N
NEW
NEW
NEW
PNX 7
PNX 7 RC
PNX 9
PNX 9 RC
PNX 12
PNX 12 RC
PNX 14
FLO 18 N
FLO 24 N
FLO 30 N
FLO 36 N
PNX 14 RC FLO 18 N RC FLO 24 N RC FLO 30 N RC FLO 36 N RC
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
kW 2.23
kW 0.68
3.3 / A
°C
2.72
0.82
3.3 / A
3.58
1.1
3.2 / A
4.22
5.35
1.33
1.66
3.2 / B
3.2 / A
21°/ 46° Dry Bulb
6.77
2.24
3.0 / B
8.5
2.9
2.9 / C
10.15
3.22
3.15 / B
Heating Capacity
Heating Capacity at -10°C out.
Power Input
COP / Label Energy
Outdoor temperature operating limits
kW 2.17
kW 1.15
kW 0.59
3.5 / B
°C
2.9
1.52
0.84
3.4 / B
4.15
2.02
1.14
3.6 / A
4.40
5.4
2.26
2.73
1.39
1.31
3.3 / C
3.5 / B
-9°/ 24° Dry Bulb
7.08
3.93
2.4
3.0/ D
9.08
4.68
2.9
3/D
11.14
5.76
3.6
3.1 / D
ST PNX 7N
280/320/380
25/27/30
0.7
11
810x210x285
ST PNX 9N
330/380/450
28/31/35
0.9
11
810x210x285
ST PNX 12N
450/550/635
35/39/43
1.3
11.5
810x210x285
ST PNX 14N
475/550/660
36/41/46
1.5
11.5
810x210x285
ST FLO 18N
750/840/930
37/40/43
1.8
14
1060X210X295
ST FLO 24N
740/820/910
42/44/47
2.3
15
1060X210X295
ST FLO 30N
1030/1100/1360
44/48/52
3.6
17
1200x236x340
ST FLO 36N
1110/1240/1360
48/50/52
4
17
1200x236x340
Part number
7SP022184
7SP022186
7SP022188
7SP022190
7SP022192
7SP022338
7SP022196
7SP022370
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
GC 7 N
GC 7 NRC
1660
48
Rotary
32
795x290x610
GC 9 N
GC 9 NRC
1780
51
Rotary
35
795x290x610
GC 12 N
GC 12 NRC
1850
51
Rotary
36
795x290x610
GC 14 N
GC 14 NRC
2160
53
Rotary
42.2
795x290x610
GC 18 N
GC 18 NRC
2480
57
Rotary
56
850x325x690
GCN 24 FLOX
GCN 24 RC FLOX
3100*
54*
Rotary*
74*
900x340x650*
GCN 30
GCN 30 RC
3150
58
Rotary
78
900x340x860
GC 37N
GC 37NRC
4150
59
Rotary
87
900x340x970
7SP061441
7SP061442
7SP061443
7SP061444
7SP061680
7SP061601
7SP061621
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
m3/h
dB(A)
l/h
kg
mm
m3/h
dB(A)
kg
mm
Power supply 1~230 V
Part number 7SP061440
Power supply 3N~400 V
Part number -
-
-
-
7SP061590
7SP061682
7SP061602
7SP061622
Power supply 1~230 V
Part number 7SP061428
7SP061429
7SP061430
7SP061431
7SP061436
7SP061681
7SP061604
7SP061630
Power supply 3N~400 V
Part number -
-
-
-
7SP061589
7SP061683
7SP061605
7SP061631
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Indoor
mm2 3x1.5
A 10
Indoor
3x1.5
10
Indoor
3x1.5
16
Indoor
3x1.5
16
Indoor
3x1.5
16
Ind. or Out.
3x2.5
20
Outdoor
3x4
25
Outdoor
3x4
25
Electrical connections Ind./Out.
mm2 4x1
4x1
4x1.5
4x1.5
4x1.5
5x1.5**
5x1.5
5x1.5
2
Electrical connections Ind./Out.
mm 5x1
5x1
5x1.5
5x1.5
5x1.5
6x1.5**
6x1.5
6x1.5
Power supply 3N~400 V
Power supply side
Power cable section
Fuse rating am
mm2 A -
-
-
-
Outdoor
5x1.5
3x10
Ind. or Out.
5x1.5
3x10
Outdoor
5x2.5
3x16
Outdoor
5x2.5
3x16
Electrical connections
mm2 -
-
-
-
5x1.5
5x1.5
5x2.5
5x1.5
Electrical connections
mm2 -
-
-
-
6x1.5
6x1.5
6x1.5
6x1.5
15
7
3/8”
1/4”
15
7
3/8”
1/4”
15
7
1/2”
1/4”
25
15
1/2”
1/4”
20
15
5/8”
3/8”
30
10
5/8”
3/8”
50
25
3/4”
3/8”
Linking pipes
Max. lenght
m
Max. height difference
m
Suction pipe diameter
Inches
Liquid pipe diameter
Inches
* Preliminary data.
** In the case of connections to an indoor unit.
15
7
3/8”
1/4”
39
Comfort R410/R407
PNX & FLO N Series
NEW
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
FLORIDA
R410A
ALASKA
R410A
LOUISIANA
R410A
Water cooled
units
Ducted
WN & WAF
Multisplits
NEW
Wall mounted
4 Cooling Only models from 2 320 to 5 150 W
4 Heat Pump models from 2 310 to 5 350 W
Indoor units WN 7/9/12
Outdoor units GC 7 A
Supplied with RC5 remote control
WAF 12
GCNG 18
> Product advantages
Sober and unobtrusive design.
Easy to install and operate.
R410A high efficiency fluid.
Class B energy label (depending on models).
Accessories
WN 7
High efficiency filtration.
Automatic treated air sweeping.
Electronic regulation and programming.
Condensate drainage lift pump (accessory).
WN 9
WN 12
WAF 18
Mounting bracket
Part number
7ACTL0016
7ACTL0016
7ACTL0016
7ACTL0016
Condensate lift pump
Part number
SAE3100
SAE3100
SAE3100
SAE3100
40
ALASKA
WN/WAF
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -10°C out.
Power Input
COP / Label Energy
Outdoor temperature operating limits
kW
kW
kW
NEW
NEW
WN 7
WN 7RC
WN 9
WN 9RC
WN 12
WN 12RC
WAF 18
WAF 18RC
2.32
0.72
3.2 / B
2.76
0.84
3.3 / A
3.6
1.12
3.2 / A
21°/ 46° Dry Bulb
5.15
1.70
3/B
2.31
1.09
0.68
3.4 / B
3.07
1.43
0.9
3.4 / B
3.84
1.12
1.17
3.4 / B
-10°/ 24° Dry Bulb
5.35
2.7
1.65
3.2 / C
ST WN 7
320/390
32/37
0.8
7
680x180x250
ST WN 9
360/450
35/41
1.2
7
680x180x250
ST WN 12
460/620
33/40
1.5
8
840x180x250
ST WAF 18
590/720
37/43
2.2
11
900x295x200
Part number
7SP022727
7SP022728
7SP022729
7SP022308
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
GC 7 A
GC 7 ARC
1200
53
Rotary
27.5
610x240x520
GC 9 A
GC 9 ARC
1370
51
Rotary
33.5
830x245x545
GC 12 A
GC 12 ARC
1450
54
Rotary
38
830x245x545
GC 18 A
GC 18 ARC
2160
54
Rotary
43
795x290x610
Part number
7SP061581
7SP061582
7SP061583
7SP061584
Part number
7SP061585
7SP061586
7SP061587
7SP061588
Indoor
3x1.5
10
4x1
5x1
Indoor
3x1.5
10
4x1
5x1
Indoor
3x1.5
10
4x1
5x1
Indoor
3x1.5
16
4x1.5
5x1.5
10
7
3/8”
1/4”
15
7
3/8”
1/4”
15
7
3/8”
1/4”
15
7
1/2”
1/4”
Indoor units
Air flow (LS/HS)
Acoustic pressure at 1m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
°C
°C
m3/h
dB(A)
l/h
kg
mm
m3/h
dB(A)
kg
mm
Comfort R410/R407
ALASKA Series
NEW
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Electrical connections
Linking pipes
Max. lenght
Max. height difference
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
mm2
m
m
Inches
Inches
41
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
FLORIDA
R410A
ALASKA
R410A
LOUISIANA
R410A
XLF
Ducted
Water cooled
units
Multisplits
NEW
Low / high Wall mounted
2 Cooling Only models from 2 590 to 3 300 W
2 Heat Pump models from 2 850 to 3 390 W
Supplied with RC4
remote control
Indoor units XLS
9/12
Unité extérieure
GCNG 9/12
> Product advantages
Low or high wall mounted installation.
Innovative, ultra-compact design (only 14 cm deep).
High performance filtration.
Electronic regulation and programming.
Treated air distribution from all 4 sides.
Ultra-quiet operation – Only 31 dBA at 1 m.
Wall mounted RCW2 remote control (accessory)
Condensate drainage lift pump (accessory).
BLOWN AIR IN 4 DIRECTIONS
Treated air is distributed in four directions. The user can direct the treated air to optimise comfort levels,
depending on the chosen operating mode:
Cooling mode: air blown upwards falls back down evenly to cool the room.
Heating mode: air blown towards the floor rises progressively to spread more effectively throughout the room.
Side blowing: ensures uniform air distribution throughout the room without creating the feeling of draughts.
Remote control RCW2
Part number 7ACEL1212
Accessories
XLF 9
XLF 12
Mounting bracket
Part number
7ACTL0016
7ACTL0016
Condensate lift pump
Part number
SAE3100
SAE3100
42
XLF 9
XLF 9 RC
XLF Series
XLF 12
XLF 12 RC
Cooling capacity
Power Input
EER / Label Energy
kW
kW
2.59
0.8
3.22/A
3.30
1.09
3.03/B
Heating Capacity
Power Input
COP / Label Energy
kW
kW
2.85
0.83
3.43/B
3.69
1.21
3.05/D
ST XLF 9
330/360/390
31/33/35
13.5
570x160x570
ST XLF 12
310/360/430
32/35/39
14
570x160x570
Part number
7SP022714
7SP022715
Outdoor units
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
GCNG 9
GCNG 9 RC
51
Rotary
34
795x290x610
GCNG 12
GCNG 12 RC
52
Rotary
35
795x290x610
Part number
7SP061441
7SP061442
Part number
7SP061429
7SP061430
Indoor
3x1.5
10
4x1.5
5x1.5
Indoor
3x1.5
10
4x1.5
5x1.5
15
7
3/8”
1/4”
15
7
3/8”
1/4”
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Weight
Dimensions (WxDxH)
m3/h
dB(A)
kg
mm
dB(A)
kg
mm
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Electrical connections
Linking pipes
Max. lenght
Max. height difference
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
mm3
m
m
Inches
Inches
43
Comfort R410/R407
LOUISIANA XLF
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
SX N R410A
S R410A
VAR R410A
CAO R407C
SX SP R407C
SX T R407C
CCE R407C
SX N
Floor/Ceiling splits
6 Cooling Only models from 2 660 to 8 520 W
6 Heat Pump models from 2 790 to 8 650 W
> Product advantages
R410A ”green” fluid.
Low wall mounted or ceiling mounted indoor units.
Automatic horizontal and vertical treated air sweeping.
Electronic regulation and programming.
Compact and lightweight for easy installation and maintenance.
Possibility of air conditioning two separate rooms with a single
indoor unit.
High efficiency filtration.
Control
panel
Indoor
units
SXN 9/12/15
NEW: SX N indoor units with R410A are compatible with GC AO R410A
cooled water units.
Ultra simple
Mounting template for
preparing both low wall
mounting and ceiling
installation.
Ultra quick
Wall bracket used for pre-fitting
and attaching pipe links
(pipe outlet possible on the rear,
left or right).
Supplied with RC4
remote control
Ultra practical
Direct access to electrical
and refrigeration connections
without dismantling the unit.
Outdoor units GCNG 9/12/15
Remote control RCW2
Part number 7ACEL1212
Accessories
Single phase electric heating
Part number
Single phase electric heating
Part number
Three phases electric heating
Part number
Condensate lift pump
Air distribution unit
SX 9 N
Capacity (W)
SX 12 N
SX 15 N
SX 18 N
SX 24 N
SX 30 N
Part number
1250
7ACEL1153
7ACFH0221
1250
7ACEL1153
1000
7ACEL1172
7ACFH0221
2000
7ACEL1154
1000
7ACEL1172
7ACFH0221
3000
7ACEL1155
1500
7ACEL1173
7ACFH0221
3000
7ACEL1155
1500
7ACEL1173
3000
7ACEL1156
7ACFH0221
3000
7ACEL1155
1500
7ACEL1173
3000
7ACEL1156
7ACFH0221
Part number
7ACVF0122
7ACVF0122
7ACVF0122
7ACVF0123
7ACVF0123
7ACVF0123
Rear panel tube cover (ceiling mounting) Part number
7ACTL0073
7ACTL0073
7ACTL0073
7ACTL0074
7ACTL0074
7ACTL0074
Mounting bracket
Part number
7ACTL0016
7ACTL0016
7ACTL0016
7ACTL0018
-
-
All seasons kit
Part number
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
Capacity (W)
Capacity (W)
NOTE : Important, installation of an all seasons kit only allows for operation in cooling mode.
44
SX 9 N
SX 9 N RC
SX 12 N
SX 12 N RC
SX 15 N
SX 15 N RC
2.66
0.82
3.2 / A
3.52
1.15
3.1 / B
4.1
1.35
3.0 / B
2.79
1.41
0.86
3.2 / C
3.7
1.87
1.15
3.2 / C
4.5
2.27
1.38
3.3 /C
SX 9 N
290/330/370
35/37/39
1.1
21
820x190x630
SX 12 N
350/390/420
38/41/45
1.5
22
820x190x630
SX 15 N
350/390/510
38/43/48
1.9
22
820x190x630
Part number
7SP012116
7SP012117
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
GC 9 NSX
GC 9 NSX RC
1780
49
Rotary
35
795x290x610
7SP061441
SX N Series
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -10°C out.
Power Input
COP / Label Energy
Outdoor temperature operating limits
kW
kW
kW
SX 24 N
SX 24 N RC
SX 30 N
SX 30 N RC
5.5
1.82
3.0 / B
21°/ 46° Dry Bulb
6.83
2.27
3.0 / B
8.52
2.99
2.9 / C
5.75
2.9
1.77
3.3 / C
-9°/ 24° Dry Bulb
7.03
3.91
2.13
3.3 / C
8.65
4.81
2.79
3.1 / D
SX 18 N
700/820/930
45/48/51
1.9
30
1 200x190x630
SX 24 N
780/900/1000
48/51/53
2.7
33
1 200x190x630
SX 30 N
700/895/1020
49/53/56
3.4
32
1 200x190x630
7SP012118
7SP012119
7SP012121
7SP012130
GC 12 NSX
GC 12 NSX RC
1850
53
Rotary
36
795x290x610
GCNG 14 N
GCNG 14 RC
2160
54
Rotary
42
795x290x610
GC 18 N
GC 18 NRC
2480
58
Rotary
56
846x302x690
GC 24 N
GC 24 NRC
3100
58
Rotary
74
900x340x697
GCN 30 N
GCN 30 NRC
3150
59
Rotary
78
900x340x860
7SP061442
7SP061443
7SP061444
7SP061594
7SP061601
°C
°C
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
m3/h
dB(A)
l/h
kg
mm
m3/h
dB(A)
kg
mm
SX 18 N
SX 18 N RC
1~230 V model
Part number
3N~400 V model
Part number
-
-
-
7SP061590
7SP061597
7SP061602
1~230 V model
Part number
7SP061554
7SP061555
7SP061431
7SP061436
7SP061596
7SP061604
3N~400 V model
Part number
-
-
-
7SP061589
7SP061598
7SP061605
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
Electrical connections
mm2
A
mm2
mm2
Indoor
3x1.5
10
4x1
5x1
Indoor
3x1.5
16
4x1.5
5x1.5
Indoor
3x1.5
16
4x1.5
5x1.5
Indoor
3x2.5
16
4x2.5
5x2.5
Ind. or Out.
3x2.5
20
5x1.5*
6x1.5*
Outdoor
3x4
25
5x1.5
6x1.5
Power supply 3N~400 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
Electrical connections
mm2
A
mm2
mm2
-
-
-
Outdoor
5x1.5
3x10
5x1.5
6x1.5
Outdoor
5x1.5
3x10
5x1.5
6x1.5
Outdoor
5x2.5
3x16
5x1.5
6x1.5
15
7
3/8”
1/4”
15
7
3/8”
1/4”
15
7
1/2”
1/4”
25
15
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
Linking pipes
Max. lenght
Max. height difference
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
* In the case of connections to an indoor unit.
45
Comfort R410/R407
CALIFORNIA SX N
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
SX N R410A
S R410A
VAR R410A
CAO R407C
SX SP R407C
SX T R407C
CCE R407C
S
NEW
Floor/Ceiling splits
2 Cooling Only models from 10 100 to 13 000 W
2 Heat Pump models from 11 000 to 13 900 W
Indoor units
S 110/130
GCN 37/43
Supplied with RC4
remote control
> Products advantages
Multi-position architecture for low wall and ceiling mounting.
Indoor units with direct blowing.
Linking pipes until 50 m.
Compatible with Airconet Regulation.
46
S 110
S 110 RC
S Series
S 130
S 130 RC
Cooling capacity
Power input
EER / Label Energy
kW
kW
10.10
3.48
2.9/F
13.00
4.56
2.85/C
Heating capacity
Power input
COP / Label Energy
kW
kW
11.00
3.90
2.82/D
13.90
4.86
2.86/D
ST S110
815/980/1180
48/52/56
45
1280x255x590
ST 130
1300/1480/1600
53/56/58
56
1585x255x590
Part number
7SP022737
7SP011076
Outdoor units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
GCN 37
GCN 37 RC
4150
61
Rotary
87
900x340x970
GCN 43
GCN 43 RC
4350
64
Scroll
96
900x340x970
Part number
7SP061622
7SP061624
Part number
7SP061631
7SP061633
1~230V
Outdoor
5x2.5
3x25
5x2.5
6x2.5
3N~400V
Outdoor
5x2.5
3x20
5x2.5
6x2.5
50
25
3/4”
3/8”
50
25
3/4”
3/8”
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Weight
Dimensions (WxDxH)
m3/h
dB(A)
kg
mm
m3/h
dB(A)
kg
mm
Comfort R410/R407
S
Linking specifications between indoor and outdoor units
Power supply
Power supply side
Power cable section
Fuse rating am
Electrical connections
Electrical connections
mm2
A
mm2
mm3
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
47
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
SX N R410A
S R410A
VAR R410A
CAO R407C
SX SP R407C
SX T R407C
CCE R407C
VAR
Monobloc air Console
1 Cooling Only model of 2 520 W
VAR 9
Control panel
> Product advantages
Monobloc console concept without an outdoor unit.
Ideal solution for premises where it is impossible
to install an outdoor unit.
Easy installation and maintenance.
Ready to operate system.
Floor mounted or low wall mounted.
Compact design.
Reinforced acoustic insulation.
R410A high efficiency fluid.
Factory-fitted 1,500 W electric heating.
LED direct control panel.
AIRCONET compatible system.
Electrostatic filter.
Condensate drainage pipe supplied.
Rear outlet grille kit supplied.
VAR Series
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
Part number
48
VAR 9
kW
kW
°C
m3/h
dB(A)
l/h
kg
mm
1~230 V model
2.52
0.97
2.6/C
21°/ 43° Dry Bulb
200/250/300
43/45/50
43
1080/230/385
7WT012047
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
SX N R410A
S R410A
VAR R410A
CAO R407C
SX SP R407C
SX T R407C
CCE R407C
CAO
Water Console
Indoor units
CAO 230 B/370 B
Comfort R410/R407
3 Cooling Only models from 2 300 to 4 700 W
CAO 580 B
> Product advantages
Easy installation and maintenance.
Ideal solution for premises where it is impossible to install
an outdoor unit.
Water condenser for use with the public water network.
Modulating regulation valve for reducing water consumption.
CAO Series
Cooling capacity
Power Input
EER / Label Energy
Operating limits indoor temperature
Condenser inlet water temperature
Indoor units
Air flow nominal (NS/LS)
New air flow
Acoustic pressure at 4m (NS/LS)
Water flow at +15 °C
Compressor type
Weight
Dimensions (WxDxH)
Power supply 1~230 V
Power cable section (without heating)
Fuse rating am
Part number
Possibility of new outdoor air intake.
Electric heating (accessory).
Remote control repeater (accessory).
Reusable air filters.
CAO 230 B
kW
kW
CAO 370 B
CAO 580 B
2.3
0.66
3.4 / E
3
0.85
3.5 / D
15°/ 32° Dry Bulb
10°/ 30°
4.7
1.3
3.6 / D
kg
mm
550/450
60
40/37
130
Rotary
48
1030x226x620
550/450
60
41/38
170
Rotary
49
1030x226x620
880/725
80
43/41
270
Rotary
69
1390x226x620
mm2
A
3x1.5
6
3x1.5
6
3x1.5
8
7CW011016
7CW011017
7CW011018
°C
°C
m3/h
m3/h
dB(A)
l/h
1~230 V model
Accessories
CAO 230 B
CAO 370 B
CAO 580 B
Single phase electric heating
Capacity (W)
Part number
2000
7ACEL0006
2000
7ACEL0006
3000
7ACEL0007
Remote control
Part number
7ACEL0039
7ACEL0039
7ACEL0039
49
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
SX N R410A
S R410A
VAR R410A
CAO R407C
SX SP R407C
SX T R407C
CCE R407C
SX SP
indoor
temperature
until 12°
Floor/Ceiling splits
5 Cooling Only models from 1 900 to 5 550 W
Outdoor units GCNG 9/12/15
Indoor units SX SP 12/15/18
> Applications
> Product advantages
Wine cellars.
Areas subject to health & safety regulations
(refuse collection areas, …).
Hospitals.
Conservation, storage, production
processes, …
Low temperature environment air
conditioning.
Accessories
Single phase electric heating
SX SP 12
Capacity (W)
Part number
1000
7ACEL1172
Indoor temperature from 12°C to 18 °C.
Floor or ceiling mounting.
Integrated or remote regulation.
All Seasons System supplied as standard equipment
with the indoor unit (to be fitted to the outdoor unit).
Anti-freezing safety protection with anti-freezing
thermostat on the indoor unit.
Electric heating (accessory).
SX SP 15
1000
7ACEL1172
SX SP 18
1000
7ACEL1172
SX SP 24
1500
7ACEL1173
SX SP 30
1500
7ACEL1173
Rear panel tube cover (ceiling mounting) Part number
7ACTL0073
7ACTL0073
7ACTL0073
7ACTL0074
7ACTL0074
Mounting bracket
7ACTL0016
7ACTL0016
7ACTL0016
7ACTL0018
7ACTL0018
50
Part number
SX SP Series
SX SP 12
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
Indoor units
Air flow
Acoustic pressure to 1m
Weight
Dimensions (WxDxH)
kW
kW
1.9
1.1
1.7 / G
2.1
1.6
1.3 / G
ST SX SP 12
350
38
20
820x190x630
ST SX SP 15
450
44
21
820x190x630
Part number
7SP012090
dB(A)
kg
mm
Part number
1~230 V model
Part number
3N~400 V model
SX SP 18
3.1
2.0
1.6 / G
-10°/ 43° Dry Bulb
SX SP 24
SX SP 30
4.4
2.2
2/G
5.5
2.5
2.2 / G
ST SX P 18
550
42
21
820x190x630
ST SX SP24
735
44
30
1200x190x630
ST SX SP 30
895
47
32
1200x190x630
7SP012091
7SP012092
7SP012093
7SP012094
GCNG 9
50
Rotary
31
760x245x545
GCNG 12
53
Rotary
37
760x245x545
GCNG 14
54
Rotary
37
760x245x545
GC 18
47
Scroll
56
850x325x690
GC 24
47
Scroll
58
850x325x690
7SP061374
7SP061378
7SP061382
7SP061336
7SP061344
-
-
-
7SP061337
7SP061345
°C
m3/h
dB(A)
kg
mm
Outdoor units
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
SX SP 15
Comfort R410/R407
CALIFORNIA
SX SP
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
mm2
A
mm2
Indoor
3x1.5
10
5x1.5
Indoor
3x1.5
10
5x1.5
Indoor
3x1.5
16
5x1.5
Ind. or Out.
3x1.5
16
5x1.5
Ind. or Out.
3x2.5
16
5x1.5
Power supply 3N~400 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
mm2
A
mm2
-
-
-
Outdoor
5x1.5
3x6
5x1.5
Outdoor
5x1.5
3x6
5x1.5
15
7
1/2”
1/4”
15
7
1/2”
1/4”
15
7
1/2”
1/4”
25
10
5/8”
3/8”
25
10
5/8”
3/8”
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
51
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
SX N R410A
S R410A
VAR R410A
CAO R407C
SX SP R407C
SX T R407C
CCE R407C
SX TELECOM
Floor/Ceiling splits
3 Cooling Only models from 5 200 to 8 400 W
Indoor unit SX 18T
> Applications
System specially designed for
process applications, equipped
with several safety systems and
full electromagnetic radiation
(EMR) protection.
Accessories
Outdoor units GC 18/24
> Product advantages
HP pressostat.
All Seasons kit -10°C.
Progressive starting.
Short cycling management.
Electromechanical regulation:
- automatic resetting in case of power cuts
- dry contact operating fault protection devices (HP safety,
anti-frost safety, excessive blown air temperature safety)
- Remote ON/OFF control.
SX 18T
SX 24T
SX 30T
Condensat lift pump
7ACFH0221
7ACFH0221
7ACFH0221
Mounting bracket
7ACTL0018
7ACTL0018
-
Rear panel tube cover
7ACTL0073
7ACTL0074
7ACTL0074
52
SX TELECOM Series
Cooling capacity
Power input
EER / Energy Label
SX 18T
kW
kW
5.2
2.1
2.5 / E
SX 24T
7.0
2.6
2.7 / D
Operating limits OUT.T
Indoor units
Air flow
Acoustic pressure at 1 m
Weight
Dimensions (WxDxH)
SX 30T
8.4
3.4
2.5 / C
-10/+46 °C
m3/h
dB(A)
kg
mm
Part number
Outdoor units
Acoustic pressure at 1 m
Compressor type
Weight
Dimensions (WxDxH)
Comfort R410/R407
SX TELECOM
dB(A)
kg
mm
ST SX 18 T
450/500/550
40/44/48
21
820x190x630
ST SX 24 T
630/735/840
43/47/50
29.5
1200x190x630
ST SX 30 T
740/895/1020
45/51/54
32
1200x190x630
7SP012097S
7SP012098S
7SP012096S
GCN 18 T
47
Scroll
56
846x302x690
GC 24
47
Scroll
56
846x302x690
GC N 30 T
41
Scroll
82
900x340x860
Part number
1~230 V model
7SP061574S
7SP061575S
7SP061576S
Part number
3N~400 V model
7SP061652S
-
7SP061573S
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
mm2
A
mm2
In. or Out.
3x2.5
12
5x1
In. or Out.
3x2.5
16
5x1
Outdoor
3x4
25
5x1
Power supply 3N~400 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
mm2
A
mm2
-
-
Outdoor
5x1.5
10
5x1.5
25
10
5/8”
3/8”
25
10
5/8”
3/8”
25
10
5/8”
3/8”
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
53
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
SX N R410A
S R410A
VAR R410A
CAO R407C
SX SP R407C
SX T R407C
CCE R407C
CCE
Column Split System
1 Heat Pump model of 15 000 W
Multifunction control panel
Automatic Cooling/ Heating
regulation.
3 fan (ventilation) speeds.
Automatic ventilation.
Night time low running
(SLEEP) function.
Dehumidification mode.
Programming (TIMER) function.
LCD display.
Indoor unit CCE 45 RC
Outdoor unit GC 45 RC
> Product advantages
Multifunction control panel with LCD display.
High efficiency filtration.
Clogged filter indicator.
Ioniser.
Automatic treated air sweeping.
54
Air range: 12 m.
Electronic regulation and programming.
Scroll compressor.
Phase controller.
Refrigeration pipe lengths up to 40 m.
Comfort R410/R407
CCE
CCE 45 Series
CCE 45 RC
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP / Label Energy
Outdoor temperature operating limits
kW
kW
Indoor unit
Air flow (HS)
Acoustic power (min/max)
Weight
Dimensions (WxDxH)
°C
°C
m3/h
dB(A)
kg
mm
12.9
4.82
2.7 / D
21°/ 46° Dry Bulb
15
4.57
3.2 / C
-9°/ 24° Dry Bulb
CCE 45
2000
52/56
70
600x370x1900
Part number
7SP022234
Outdoor unit
Compressor type
Acoustic power
Weight
Dimensions (WxDxH)
GC CCE 40 RC
Scroll
69
95
900x340x970
dB(A)
kg
mm
Part number
7SP061521
Linking specifications between indoor and outdoor units
Power supply 3N~400 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. height difference
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
m
m
Inches
Inches
Outdoor
5x1.5
10
6x1.5
40
20
3/4”
3/8”
55
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
KN R410A
KXL N R410A
MD R407C
Multisplits
KN/KXL N
Cassettes
8 Cooling Only models from 2 820 to 12 350 W
8 Heat Pump models from 3 020 to 13 200 W
Outdoor units GCNG 9/12/14
Indoor units
KXL N 24/30/36/45
Indoor units
KN 9/11/15/18
Supplied with RC4
remote control
GCN 37/43
> Product advantages
Designed for suspended ceiling integration.
900 x 900 mm format (KXL).
600 x 600 mm format (KN).
Built-in depth: 287 mm (KN).
Built-in depth: 230 mm for KXL 24 and 30
models.
Electronic regulation and programming.
Four powered blown air flaps (KXL).
New air intake (KN).
Possibility of air conditioning an adjacent room (KN).
Quick access to all components after simply removing
the facade.
Phase controller.
Integrated condensate drainage lift pump.
Wall mounted RCW2 remote control (accessory).
Solid ceiling frame (KN accessory).
NEW: KN/KXL N indoor units with R410A are compatible with GCAO R410A cooled water units.
SIMPLIFIED INSTALLATION AND MAINTENANCE
LOW BUILT-IN HEIGHT
Condensate
drainage lift
pump.
247 mm
230 mm
Low noise level
turbine.
New
air
intake.
Slide mounted
electrical
cabinet.
Condensate drainage lift pump
supplied as standard equipment.
Lift height up to 600 mm. 1 single
attachment point for easy maintenance.
Direct access to all electrical
connections and electronic
components mounted on a
sliding drawer.
KN
KXL N
Remote control RCW2
Part number 7ACEL1212
Accessories
K9 N
K11 N
K15 N
K18 N
KXL N 24
KXL N 30
KXL N 36
KXL N 45
Ceiling adapter frame
Part number 7ACVF0091
7ACVF0091
7ACVF0091
7ACVF0091
-
-
-
-
Mounting bracket
Part number 7ACTL0016
7ACTL0016
7ACTL0016
7ACTL0018
7ACTL0018
7ACTL0018
7ACTL0013
7ACTL0013
All seasons kit
Part number 7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
7ACFH0480
56
COLORADO
KN/KXL N
K11 N
K11 NRC
K15 N
K15 NRC
K18 N
K18 NRC
KXL N 24
KXL N 30
KXL N 36
KXL N 45
KXL N 24 RC KXL N 30 RC KXL N 36 RC KXL N 45 RC
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
kW 2.82
kW 0.86
3.3 / A
°C
3.68
1.14
3.2 / A
4.35
1.35
3.2 / A
5.5
6.8
1.82
2.25
3.0 / B
3.0 / B
21°/ 46° Dry Bulb
8.3
2.9
2.9 / C
9.7
3.48
2.8 / C
12.35
4.4
2.8 / C
Heating Capacity
Heating Capacity at -10°C out.
Power Input
COP / Label Energy
Outdoor temperature operating limits
kW 3.02
kW 1.53
kW 0.83
3.6 / A
°C
3.81
1.92
1.11
3.4 / B
4.46
2.25
1.23
3.6 / A
5.75
7.08
2.9
3.93
1.67
2.33
3.4 / B
3.0 / D
-9°/ 24° Dry Bulb
8.94
4.97
2.88
3.1 / D
10.3
3.6
2.8 / D
14
5.5
2.54 / F
K9 N
430/470/580
35/36/41
0.8
23
571x571x287
625x625x40
Included
K11 N
375/500/580
34/36/41
1.3
24
571x571x287
625x625x40
Included
K15 N
430/550/630
36/41/44
1.6
26
571x571x287
625x625x40
Included
K18 N
590/660/760
44/46/49
2.4
26
571x571x287
625x625x40
Included
KXL 24 N
690/800/910
38/41/44
2.5
36
840x840x230
950x950x46
7ACVF0321
KXL 30 N
985/1120/1200
47/50/52
3.2
36
840x840x230
950x950x46
7ACVF0321
KXL 36 N
1025/1125/1220
42/44/46
4.1
48
840x840x300
950x950x46
7ACVF0321
KXL 45 N
1200/1330/1600
46/49/55
5.4
48
840x840x300
950x950x46
7ACVF0321
Part number
7SP042091
7SP042092
7SP042093
7SP042094
7SP042096
7SP042156
7SP042172
7SP042173
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
GC 9 N
GC 9 NRC
1780
49
Rotary
35
795x290x610
GC12 N
GC12 NRC
1850
53
Rotary
36
795x290x610
GC14 N
GC14 NRC
2160
54
Rotary
42
795x290x610
GC 18 N
GC 18 NRC
2480
58
Rotary
56
846x302x690
GCN 24
GCN 24 RC
3100
58
Rotary
78
900x340x680
GCN 30
GCN 30 RC
3150
59
Rotary
78
900x340x860
GCN 37
GCN 37 RC
4150
61
Scroll
96
900x340x900
GCN 43
GCN 43 RC
4350
64
Scroll
96
900x340x860
1~230 V model
Part number 7SP061441
7SP061442
7SP061443
7SP061444
7SP061594
7SP061601
7SP061621
-
3N~400 V model
Part number -
-
-
7SP061590
7SP061597
7SP061602
7SP061622
7SP061624
1~230 V model
Part number 7SP061429
7SP061430
7SP061431
7SP061436
7SP061596
7SP061604
7SP061630
-
3N~400 V model
Part number -
-
-
7SP061589
7SP061598
7SP061605
7SP061631
7SP061633
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1m (LS/NS/HS)
Dehumidification
Weight
Built in casing (WxDxH)
Frame (WxDxH)
Part number frame
m3/h
dB(A)
l/h
kg
mm
mm
m3/h
dB(A)
kg
mm
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
Electrical connections
mm2
A
mm2
mm2
Indoor
3x1.5
10
4x1
5x1
Indoor
3x1.5
16
4x1.5
5x1.5
Indoor
3x1.5
16
4x1.5
5x1.5
Ind. or Out.
3x2.5
16
4x2.5*
5x2.5*
Ind. or Out.
3x2.5
20
4x2.5*
5x2.5*
Outdoor
3x4
25
5x1.5
6x1.5
-
-
Power supply 3N~400 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
Electrical connections
mm2
A
mm2
mm2
-
-
-
Outdoor
5x1.5
3x8
5x1.5
6x1.5
Outdoor
5x1.5
3x10
5x1.5
6x1.5
Outdoor
5x1.5
3x16
5x1.5
6x1.5
Outdoor
5x2.5
3x20
5x1.5
6x1.5
Outdoor
5x2.5
3x25
5x1.5
6x1.5
15
7
3/8”
1/4”
15
7
3/8”
1/4”
15
7
1/2”
1/4”
25
15
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
50
25
3/4”
3/8”
50
25
3/4”
3/8”
Linking pipes
Max. lenght
m
Max. height difference
m
Suction pipe diameter
Inches
Liquid pipe diameter
Inches
* In the case of connections to an indoor unit.
57
Comfort R410/R407
K9 N
K9 NRC
KN/KXL N Series
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
KN R410A
KXL N R410A
MD R407C
Multisplits
MD
Ducted Cassettes
5 Heat Pump models from 9 100 to 14 500 W
Indoor units MD 35/38/50
Outdoor units GCN 36/43
Supplied with RC4
remote control
> Product advantages
Installation possible in a corridor (width: 850 mm),
suspended ceiling installation.
Built-in depth: only 300 mm!
Air intake via room grille, air distribution via outlets on
opposite sides.
Available air pressure for connection to a duct network.
Possibility of air conditioning up to 6 rooms.
Condensate drainage lift pump
(up to 600 mm lift height).
New air intake.
Complete accessibility via the unit underside.
Remote control RCW2
Part number 7ACEL1212
Accessories
MD 35
MD 38
MD 38 DS
MD 50
Air dosing flap
Part number
7ACVF0290
7ACVF0290
7ACVF0290
7ACVF0290
New air intake
Part number
7ACVF0291
7ACVF0291
7ACVF0291
7ACVF0291
Vave-damper 3x8”
Part number
-
-
7ACFH0446
-
Vave-damper 4x8”
Part number
-
-
7ACFH0380
-
Vave-additional damper 10”
Part number
-
-
7ACFH0447
-
58
MD
MD 35 RC
MD 38 RC
MD 38 DS RC
MD 50 RC
1~230 V
3N~400 V
3N~400 V
3N~400 V
3N~400 V
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
kW
kW
9.1
3.58
2.54 / E
8.8
3.37
2.61 / D
10.4
3.85
2.70 / D
21°/46° Dry Bulb
10.5
4.04
2.61/ D
12.6
5.2
2.42 / E
Heating Capacity
Power Input
COP / Label Energy
Outdoor temperature operating limits
kW
kW
9.1
3.15
2.88 / D
8.79
3.03
2.90 / D
11.1
3.94
2.81 / D
-9°/24° Dry Bulb
11.4
3.9
2.93/ D
14.5
5.18
2.79 / E
ST MD 35
1200/1330/1700
2/8
45/47/52
43
1 025x760x300
1 050x800x100
ST MD 38
1200/1330/1700
2/8
47/50/52
44
1 025x760x300
1 050x800x100
ST MD 38 DS
1200/1330/1700
2/8
47/50/52
44
1 025x760x300
1 050x800x100
ST MD 50
1230/1350/2000
2/8
47/50/53
44
1 025x760x300
1 050x800x100
7SP022137
7SP022138
7SP022200
7SP022139
GCN 30 RC
Scroll
61
84
900x340x860
GCN 36 RC
Scroll
65
95
900x350x970
GCN 36 DS RC
Scroll
69
90
900x350x970
GCN 43 RC
Scroll
65
95
900x350x970
Indoor units
Air flow (LS/NS/HS)
Available static pressure (min./max.)
Acoustic pressure to 1m (LS/NS/HS)
Weight
Flush mounted indoor unit (WxDxH)
Frame (WxDxH)
Power supply 1~220 V
m3/h
daPa
dB(A)
kg
mm
mm
Part number
Outdoor units
Compressor type
Acoustic pressure to 1m
Weight
Dimensions (WxDxH)
dB(A)
kg
mm
Power supply 1~230 V
Part number
7SP061389
-
-
-
-
Power supply 3N~400 V
Part number
-
7SP061391
7SP061398
7SP061437
7SP061399
Linking specifications between indoor and outdoor units
Power supply 1~230 V-50 Hz
Power supply side
Power cable section
Fuse rating am (1~230 V)
Electrical connections
mm2
A
mm2
Outdoor
3x4
25
6x2.5+2x0.5
-
-
-
-
Power supply 3N~400 V- 50 Hz
Power supply side
Power cable section
Fuse rating am (3N~400 V)
Electrical connections
mm2
A
mm2
-
Outdoor
5x4
3x16
6x1.5+2x0.5
Outdoor
5x1.5
3x10
6x1.5+2x0.5
Outdoor
5x1.5
3x16
6x1.5+2x0.5
Outdoor
5x2.5
3x16
6x1.5+2x0.5
30
10
5/8”
3/8”
16
30
10
5/8”
3/8”
16
30
25
3/4”
3/8”
16
50
25
3/4”
3/8”
16
50
25
3/4”
3/8”
16
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
Condensate drainage pipe (diameter)
m
m
Inches
Inches
mm
59
Comfort R410/R407
MD Series
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
BS/DLS R410A
CD R407C
Multisplits
BS/DLS
Ducted units
7 Cooling Only models from 3 400 to 12 400 W
7 Heat Pump models from 3 400 to 13 100 W
Indoor units
DLS 18/24/30
Indoor units
BS 11/15
Supplied with RC4
remote control
Outdoor unit GCN 30
Receiver
> Product advantages
Low silhouette ducted units.
Suspended ceiling installation.
Low built-in height: BS = 245 mm; LS = 260 mm.
Compact DLS indoorunits.
Horizontal or vertical mounting
(BS11 and 15 models).
High available air pressure for connection to a duct
network.
New centrifugal fan type: DLS.
Low noise levels.
Electronic regulation and programming.
Air filter supplied, easy access: DLS.
Set of accessories for air intake and blowing via
ducts or grilles (BS11 and 15 models).
Air blowing plenum kit (DLS model).
Electric heating (accessory).
NEW: DLS indoor units with R410A are compatible with GCAO R410A cooled water units.
ATTENTION: DLS units equipped with an electric heating battery are not compatible with the GCAO.
Remote control RCW2
Only for BS.
Part number 7ACEL1212
Accessories
DLS 18
DLS 24
DLS 30
DLS 37
DLS 44
Single phase electric heating Capacity (W) 1600
Part number 7ACEL1305
BS 11
1600
7ACEL1305
BS15
2000
7ACEL1358
2000
7ACEL1358
3000
7ACEL1359
4000
7ACEL1360
4000
7ACEL1360
N°1 cassette air intake plenum kit Part number 7ACVF0075
7ACVF0075
-
-
-
-
-
N°2 duct connection plenum kit
Part number 7ACVF0073
7ACVF0073
-
-
-
-
-
Air supply plenum
Part number -
-
7ACVF0317
7ACVF0317
7ACVF0317
7ACVF0318
7ACVF0318
Mounting bracket
Part number 7ACTL0016
7ACTL0016
7ACTL0018
-
-
-
-
All seasons kit
Part number -
-
7ACFH0480
7ACFH0480
7ACFH0480
-
-
NOTE : Important, installation of an all seasons kit only allows for operation in cooling mode.
60
BS/DLS
BS15
BS15 RC
DLS 18
DLS 24
DLS 30
DLS 37
DLS 44
DLS 18 RC DLS 24 RC DLS 30 RC DLS 37 RC DLS 44 RC
Cooling capacity
Power Input
EER / Label Energy
Outdoor temperature operating limits
kW 3.4
kW 1.23
2.8 / C
°C
4.4
1.64
2.7 / D
5.6
1.8
3.1 / B
6.9
8.5
2.4
3
2.9 / C
2.8 / C
21°/ 46° Dry Bulb
10.6
3.8
2.8 / C
12.4
4.3
2.8 / C
Heating Capacity
Heating Capacity at -10°C out.
Power Input
COP / Label Energy
Outdoor temperature operating limits
kW 3.4
kW 2.4
kW 1.2
2.8 / D
°C
4.4
3.4
1.48
3.0 / D
5.3
2.94
1.7
3.1 / D
7
3.89
2.3
3.0 / D
-9°/ 24° Dry Bulb
9
5
2.8
3.2 / C
11.2
6.22
3.7
3.1 / D
13.1
7.67
4.3
3.0 / D
BS11
360/450/580
30
33/35/42
1.3
30
860x680x245
BS15
600/680/730
30
43/45/47
1.7
31
860x680x245
DLS18
730/875/1150
25/60
40/42/45
2
29
790x749x256
DLS24
840/1100/1210
25/60
43/45/48
2.3
29
790x749x256
DLS30
935/1150/1420
37/80
44/46/49
3
31
790x749x256
DLS37
1210/1520/1840
37/100
45/48/51
3.7
33
852x816x297
DLS44
1250/1490/2040
50/100
47/49/52
4.7
33
852x816x297
7SP022128
7SP022129
7SP022315
7SP022316
7SP022317
7SP022318
7SP022319
GCNG 14 BS
GCNG 14 BSRC
55
Rotary
42
795x290x610
GC 18 N
GC 18 NRC
58
Rotary
56
846x302x690
GCN 24
GCN 24 RC
58
Rotary
78
900x340x680
GCN 30 N
GCN 30 NRC
58
Rotary
78
900x340x860
GCN 37 N
GCN 37 NRC
63
Rotary
87
900x340x970
GCN 40 N
GCN 40 NRC
64
Scroll
87
900x340x970
Indoor units
Air flow (LS/NS/HS)
Static pressure (LS/HS)
Acoustic pressure to 1m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
m3/h
Pa
dB(A)
l/h
kg
mm
Part number
GCNG 12
GCNG 12 RC
dB(A) 53
Rotary
kg 39
mm 795x290x610
Outdoor units
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
1~230 V model
Part number 7SP061378
7SP061382
7SP061444
7SP061594
7SP061601
7SP061621
-
3N~400 V model
Part number -
-
7SP061590
7SP061597
7SP061602
7SP061622
7SP061623
1~230 V model
Part number 7SP061379
7SP061552
7SP061436
7SP061596
7SP061604
7SP061630
-
3N~400 V model
Part number -
-
7SP061589
7SP061598
7SP061605
7SP061631
7SP061632
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
Electrical connections
mm2
A
mm2
mm2
Indoor
3x1.5
10
5x1.5
6x1.5
Indoor
3x1.5
16
5x1.5
6x1.5
Indoor
3x2.5
20
4x2.5
6x2.5
Ind. or Out.
3x2.5
20
5x1.5*
6x1.5*
Outdoor
3x4
25
5x1.5
6x1.5
Outdoor
3x4
25
5x1.5
6x1.5
-
Power supply 3N~400 V
Power supply side
Power cable section
Fuse rating am
Electrical connections
Electrical connections
mm2
A
mm2
mm2
-
-
Outdoor
5x1.5
3x10
5x1.5
6x1.5
Outdoor
5x1.5
3x10
5x1.5
6x1.5
Outdoor
5x2.5
3x16
5x1.5
6x1.5
Outdoor
5x2.5
3x16
5x2.5
6x1.5
Outdoor
5x2.5
3x16
5x2.5
6x1.5
15
7
1/2”
1/4”
15
7
1/2”
1/4”
25
15
1/2”
1/4”
50
25
5/8”
3/8”
50
25
5/8”
3/8”
50
25
3/4”
3/8”
50
25
3/4”
3/8”
Linking pipes
Max. lenght
m
Max. height difference
m
Suction pipe diameter
Inches
Liquid pipe diameter
Inches
* In the case of connections to an indoor unit.
61
Comfort R410/R407
BS 11
BS 11 RC
BS/DLS Series
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
BS/DLS R410A
CD R407C
Multisplits
CD
Ducted
2 Cooling Only models from 14 500 to 16 900 W
2 Heat Pump models from 14 300 to 17 200 W
Helicoidal outdoor unit
GC CD 60
Indoor unit CD 50/60
Supplied with RC4
remote control
Receiver
Centrifugal outdoor unit GCCH 50/60
> Product advantages
Suspended ceiling installation.
Horizontal mounting.
Reusable air filter.
Pressure available for connection to a duct network.
Condensate group for centrifugal and helicoidal ventilation, mounting in outdoor or technical local.
High available static pressure.
Remote control RCW2
Part number 7ACEL1212
Accessories
CD 50
CD 60
For model 60 (8 100 W)
Part number
7ACEL1097
7ACEL1185
For model 60 (12 000 W)
Part number
-
7ACEL1184
62
CD
CD 50
CD 50 RC
BS/CD Series
Cooling capacity
Power input
EER / Energy Label
Operating limits OUT.T
kW
kW
Heating capacity
Power input
COP / Energy Label
Operating limits OUT.T
kW
kW
Comfort R410/R407
NEW
CD 60
CD 60 RC
14.5
5.7
2.54 / E
16.9
7
2.41 / E
10/46°C Dry Bulb
14.3
5.9
2.4 / F
17.2
6.37
2.7 / E
-9/24°C Dry Bulb
Indoor units
Air flow (LS/MS/HS)
Available static pressure (LS/MS/HS)
Acoustic pressure at 1 m (MV)
Weight
Dimensions (WxDxH)
m3/h
daPa
dB(A)
kg
mm
Part number
Outdoor units
Compressor type
Acoustic pressure at 1 m
Weight
Dimensions ( WxDxH)
dB(A)
kg
mm
ST CD 50
2800
8
52
65
1350x740x340
STCD 60
3500
15
60
68
1350x745x400
7SP032017
7SP032032
Helicoidal
GC CD 50
GC CD 50 RC
Scroll
52
120
900x340x1255
Centrifugal
GC CH 50
GC CH 50 RC
Scroll
52
196
1600x900x651
Helicoidal
GC CD 60
GC CD 60 RC
Scroll
55
124
900x340x1255
Centrifugal
GC CH 60
GC CH 60 RC
Scroll
50
196
1600x900x651
Part number
Power supply 3N~400 V
7SP071126
7SP071113
7SP071127
7SP071115
Part number
Power supply 3N~400 V
7SP071130
7SP071114
7SP071131
7SP071116
Linking specifications between indoor and outdoor units
Power supply 3N~400 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections In./Out.
Electrical connections In./Out.
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
mm2
m
m
Inches
Inches
Outdoor
5x1.5
3x25
4x1.5
5x1.5
Outdoor
5x2.5
3x20
4x1.5
5x1.5
30
30
7/8”
5/8”
50
30
7/8”
5/8”
63
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
GCAON R410A
GCAO N
NEW
Water cooled units
7 Cooling Only models from 2 400 to 9 100 W
Water cooled unit
GCAO N
> Product advantages
NEW : Connection to R410A indoor units.
Ideal solution for premises where it is impossible
to install an outdoor unit.
Connection to recycled or lost water systems.
”Lego” concept for combinations with all types
of indoor units.
Water intake and drainage via public water network.
Pressostat valve supplied (to limit water
consumption).
High Pressure safety pressostat valve with manual
reset.
Remote control RCW2
Part number 7ACEL1212
64
GCAO N
GCAO 7 N
Cooling capacity
Power Input
EER / Label Energy
Operating limits indoor temperature
Condenser inlet water temperature
GCAO 12 N
GCAO 15 N
2.95
0.68
4.34 / A
3.85
0.95
4.05 / A
120
600
49
Rotary
41
437x401x435
160
850
49
Rotary
45
437x401x435
190
1 000
49
Rotary
46
437x401x435
7SP101040
7SP101041
Power supply 1~230 V
Power supply side
Outdoor
Power cable section (without heating) mm2 3x1.5
Fuse rating am (without heating)
A 10
Electrical connections
mm2 3x1.5
Outdoor
3x1.5
10
3x1.5
Power supply 3N~400 V
Power supply side
Power cable section (without heating) mm2 Fuse rating am (without heating)
A Electrical connections
mm2 Linking pipes
Max. lenght
Max. height difference
Suction pipe diameter
Liquid pipe diameter
Outdoor units
Waste water flow at + 15°C
Recycled water flow: 26/32°C
Acoustic pressure at 4 m
Compressor type
Weight
Dimensions (WxDxH)
Part number
kW 2.45
kW 0.51
4.80 / A
°C
°C
GCAO 9 N
l/h 90
l/h 500
dB(A) 49
Rotary
kg 40
mm 437x401x435
1~230 V model 7SP101039
GCAO 18 N
4.60
5.85
1.12
1.34
4.11 / A
4.37 / A
17°/ 32° Dry Bulb
10°/45°
GCAO 24 N
GCAO 30 N
7.15
1.90
3.76 / A
8.60
2.30
3.74 / A
250
1 250
51
Rotary
50
522x421x535
320
1 550
53
Reciprocating
56
522x421x535
360
1 900
53
Reciprocating
64
522x421x535
7SP101042
7SP101045
7SP101044
7SP101043
Outdoor
3x1.5
10
3x1.5
Outdoor
3x1.5
10
3x1.5
Outdoor
3x1.5
10
3x1.5
Outdoor
4x2.5
16
4x2.5
Outdoor
3x4
20
4x4
-
-
-
Outdoor
5x1.5
3x6
5x1.5
Outdoor
5x1.5
3x10
5x1.5
Outdoor
5x1.5
3x12
5x1.5
16
15
3/8”
1/4”
25
15
3/8”
1/4”
25
15
1/2”
1/4”
25
15
1/2”
1/4”
25
15
5/8”
3/8”
25
15
5/8”
3/8”
Linking specifications between indoor and outdoor units
m
m
Inches
Inches
10
10
3/8”
1/4”
Compatibility guide
GCAO 7 N
GCAO 9 N
GCAO 12 N
GCAO 15 N
GCAO 18 N
GCAO 24 N
GCAO 30 N
PNX 7
Part number 7SP022704
PNX 9
7SP022705
PNX 12
7SP022706
PNX 14
7SP022707
FLO 18 N
7SP022192
FLO 24 N
7SP022338
FLO 30 N
7SP022196
Part number -
SX 9 N
7SP012116
SX 12 N
7SP012117
SX 15 N
7SP012118
SX 18 N
7SP012119
SX 24 N
7SP012121
SX 30 N
7SP012130
Part number -
K9 N
7SP042091
K11 N
7SP042092
K15 N
7SP042093
K18 N
7SP042094
KXL N 24
7SP042096
KXL N 30
7SP042156
WN 7
Part number 7SP022727
WN 9
7SP022728
WN 12
7SP022729
-
WAF 18
7SP022308
-
-
Part number -
-
-
-
DLS18
7SP022315
DLS24
7SP022316
DLS30
7SP022317
65
Comfort R410/R407
GCAO N Series
Monoblocs
Wall mounted
Floor/Ceiling
splits
Cassettes
Ducted
Water cooled
units
Multisplits
DUO R410A
DUO R410A
Multisplits
2 Cooling Only models from 5 720 to 5 930 W
5 Heat Pump models from 5 370 to 14 200 W
DUO 18/18-24/24
DUO 9/9-9/12-12/12
> Product advantages
Compact outdoor units.
Units equipped with 2 compressors.
Independent operation of each indoor unit.
Outdoor units compatibles with PHOENIX,
FLORIDA N and ALASKA indoor units.
R410A ”green” fluid.
Rotary compressor.
Hydrophilic condenser coating.
Heating mode operation down to outdoor
temperatures of -10° C.
Silent running.
Compatibility guide
Wall mounted ALASKA
Cooling Capacity
Heating capacity
Air flow (PV/GV)
Acoustic pressure to 1 m (LS/HS)
Weight
Dimensions
WN 9
kW
kW
m3/h
dB(A)
kg
mm
Part number
Wall mounted PHOENIX/FLORIDA N
Cooling Capacity
Heating capacity
Air flow (PV/MV/GV)
Acoustic pressure to 1 m (LS/NS/HS)
Weight
Dimensions
Part number
66
kW
kW
m3/h
dB(A)
kg
mm
WN 12
2.64
2.80
360/450
35/41
7
680x180x250
3.50
3.8
460/620
33/40
8
840x180x250
7SP022728
7SP022729
PNX 9
PNX 12
FLO 18 N
FLO 24 N
2.72
3
330/380/450
28/31/35
11
810x190x285
3.63
4
450/550/635
35/39/43
11.5
810x190x285
5.35
5.4
750/840/930
37/40/43
14
1060x210x295
6.77
7.08
740/820/910
42/44/47
15
1060x210x295
7SP022705
7SP022706
7SP022192
7SP022338
Comfort R410/R407
DUO R410A
DUO 9-9
DUO 9-9 RC
DUO R410A Series
DUO 9-12
DUO 9-12 RC
DUO 12-12 RC
DUO 18-18 RC
DUO 24-24 RC
Cooling capacity
Power Input
Outdoor temperature operating limits
kW
kW
°C
5.72 (2x2.86)
1.9
5.93 (2.86+3.07)
2.07
7 (3.5x2)
2.5
21°/ 46° Dry Bulb
10.7 (5.35x2)
3.32
13 (6.5x2)
4.6
Heating Capacity
Power Input
Outdoor temperature operating limits
kW
kW
°C
5.37 (2.6x2)
1.79
6.13 (2.6 + 3.53)
1.97
7.03 (3.51x2)
2.51
-10°/ 24° Dry Bulb
10.8 (5.4x2)
3.32
14.2 (7.0x2)
4.81
1 100 / 1 520
59
Rotary
72
900x340x680
1 100/ 1 520
59
Rotary
74
900x340x680
1100/1520
59
Rotary
74
900x340x680
4500
60
Rotary
110
950x340x1270
4950
62
Rotary
110
950x340x1270
Outdoor units
Air flow
Acoustic pressure to 1m
Compressor type
Weight
Dimensions (WxDxH)
m3/h
dB(A)
kg
mm
Part number
1~230 V model
7SP091134
7SP091133
-
-
-
Part number
1~230 V model
7SP091131
7SP091132
7SP091138
7SP091139
7SP091140
Outdoor
3x2.5
16
6x1.5
Outdoor
3x2.5
16
6x1.5
Outdoor
3x2.5
16
6x1.5
Outdoor
3x2.5
16
6x1.5
Outdoor
5x2.5
16
6x1.5
15
7
2x3/8”
2x1/4”
15
7
2x3/8”
2x1/4”
15
7
2x3/8”
2x1/4”
25
15
2x1/2”
2x1/4”
25
15
2x5/8”
2x3/8”
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Max. height difference
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
m
m
Inches
Inches
67
INDUSTRIAL
RANGE
> An air of power
Based on its incomparable expertise on this core market, with its 2007 Industrial range, Airwell offers a vast choice
of system capacities up to 84,000 Watt. Air or water condenser vertical cabinet units, Ducted packaged units, Rooftop units:
a comprehensive range of systems to match all your requirements. In addition, the DKDN and HA systems are equipped
with an intelligent CAC controller microprocessor control facility. This high-tech PCB not only provides easy access
to all system statuses, alarms and sensor data, but also generates significant energy savings, sets the de-icing time
duration, etc.
68
Industrial
Vertical
cabinet units
p.70
Packaged
Split-System
p.74
Rooftop
p.76
69
Vertical cabinet units
XAR R407C
Packaged Split-System
Rooftop
XAO R407C
X AR
Vertical air cabinets
6 Cooling Only models from 9 700 to 55 000 W
X 2450 AR*
Indoor unit X 1100 AR*
Outdoor units UC 33-53
> Product advantages
Easy installation and maintenance.
Split system with outdoor condenser fan units.
Treated air distribution to premises by plenum or duct network.
Adjustable available static pressure.
Thermostat temperature regulation.
Electrical, refrigeration and thermal protection devices.
Electric heating (accessory).
Accessories
X 1100 AR
X 1900 AR
Hot water coil battery heating (accessory).
”All Seasons” system
(Cooling mode operation down to outdoor
temperatures of -10° C).
Remote fault reporting (accessory).
Plenum, duct flanges (accessory).
X 2450 AR
X 3250 AR
X 4650 AR
X6450 AR
Set of female valves
Part nbr
7ACFH0054
7ACFH0055
7ACFH0056
7ACFH0061
7ACFH0057
7ACFH0060
Pipe links
Part nbr
7ACFH0210 (1)
7ACFH0211
7ACFH0212
7ACFH0213
7ACFH0214
7ACFH0215
Electric heating
Capacity (W)
Part nbr
9000
7ACEL0042
12000
7ACEL0043
18000
7ACEL0057
22500
7ACEL0058
37500
7ACEL0116
45000
7ACEL0119
Hot water heating (water at 90/80 °C)
Confirm left or right side outlet
Capacity (W)
Part nbr
15500
7ACFH0062
29700
7ACFH0063
38500
7ACFH0064
50000
7ACFH0118
77000
7ACFH0180
94000
7ACFH0170
7ACEL0032
Combined ON/OFF switch and room thermostat (2) Part nbr
7ACEL0041
7ACEL0041
7ACEL0032
7ACEL0032
7ACEL0032
”High Ventilation”
Part nbr
7ACVF0023
7ACVF0024
-
-
-
-
”All seasons” system
Part nbr
7ACFH0069
7ACFH0070
7ACEL0104
7ACFH0072
7ACFH0071
7ACFH0146
Remote fault reporting kit
Part nbr
-
-
7ACEL0072
7ACEL0072
7ACEL0071
7ACEL0071
Air distribution duct frame
Part nbr
7ACVF0101
7ACVF0102
7ACVF0050
7ACVF0051
7ACVF0052
7ACVF0052
Total rear air intake duct frame
Part nbr
7ACVF0041
7ACVF0104
7ACVF0043
7ACVF0044
7ACVF0045
7ACVF0046
Front air distribution plenum
Part nbr
7ACVF0105
7ACVF0106
7ACVF0108
7ACVF0109
7ACVF0110
7ACVF0111
-
-
-
-
New air intake
Part nbr 7ACVF0047
7ACVF0047
(1) Pipe lenghts up to 15m: ref 7ACFH0296 . (2) Switch assembly to be fitted in the room.
* Switch assembly to be fitted in the room.
70
X AR Series
X 1100 AR
X 1900 AR
X 2450 AR
X 3250 AR
X 4650 AR
X6450 AR
9.7
4.55
2.13
16.2
6.8
2.38
19.8
8.9
2.22
29
12.63
2.30
38.9
16.95
2.29
55
24
2.29
2000
1500/2500
20
66
1
136
890x430x1540
220
3200
2500/3800
30
68
1
182
1000x500x1735
260
4500
3600/5400
20
75
1
265
1300x600x1840
350
5800
4600/7000
20
81
1
350
1530x600x1840
350
9000
7200/10800
25
77
2
525
1715x790x1970
400
12000
9500/14500
29
85
2
600
1980x790x1970
400
Part number
7XU022082
7XU022077
7XU022078
7XU022079
7XU022080
7XU022081
Outdoor units
Number of UC
Acoustic pressure
Weight
Dimensions (WxDxH)
UC 33 A
1
54
59
885x825x831
UC 53 A
1
58
68
885x825x832
UC 73 A
1
61
93
1141x885x831
UC 103 A
1
73
130
1546x885x893
UC 73 A
2
64
93
1141x885x831
UC 103 A
2
76
130
1546x885x893
7XU031025
7XU031026
7XU031027
7XU031028
2 x 7XU031027
2 x 7XU031028
5x2.5
16
5x1.5
5x2.5
25
5x1.5
5x4
25
5x1.5
5x6/ 5x10
32/40
5x1.5
5x10
50
6x1.5
5X16 / 5X25
63/80
6x1.5
45
1/2”
3/8”
45
1/2”
3/8”
45
5/8”
1/2”
45
3/4”
5/8”
45
5/8”
1/2”
45
3/4”
5/8”
Cooling Capacity
Power input
EER
kW
kW
Indoor units
Nominal air flow
Air flow range (min./max.)
Available static pressure (max.)
Acoustic pressure
Number of circuits
Weight
Dimensions (WxDxH)
Air distribution plenum (height) (1)
Part number
m3/h
m3/h
daPa
dB(A)
kg
mm
mm
dB(A)
kg
mm
3N~400 V model
Linking specifications between indoor and outdoor units
Power supply 3N~400 V
Power cable section
Fuse rating am
Electrical connections
Linking pipes
Max. lenght
Suction pipe diameter
Liquid pipe diameter
mm2
A
mm2
m
Inches
Inches
(1) Plenum in accessories.
71
Industrial
X AR
Vertical cabinet units
XAR R407C
Packaged Split-System
Rooftop
XAO R407C
X AO
Vertical water cabinets
6 Cooling Only models from 8 000 to 45 700 W
X 4650 AO*
Indoor unit CX 25*
> Product advantages
Easy installation and maintenance.
Monobloc system.
Operating with mains or recycled water.
Treated air distribution to premises by plenum
or duct network.
Adjustable available static pressure.
Thermostat temperature regulation.
Electrical accessories
Electrical, refrigeration and thermal protection devices.
Electric heating (accessory).
Hot water coil battery heating (accessory).
”All Seasons” system (Cooling mode operation down
to outdoor temperatures of -10° C).
Remote fault reporting (accessory).
Plenum, duct flanges (accessory).
CX 25
X 1100 AO
X 1900 AO
X 2450 AO
X 3250 AO
X 4650 AO
Electric heating 1~230 V
Capacity (W)
Part nbr
5490
7ACEL0017
-
-
-
-
-
Electric heating 3N~400 V
Capacity (W)
Part nbr
5490
7ACEL0018
9000
7ACEL0042
12000
7ACEL0043
18000
7ACEL0057
22500
7ACEL0058
37500
7ACEL0116
Hot water heating (water 90/80 °C)
Confirm left or right side outlet
Capacity (W)
Part nbr
-
15500
7ACFH0062
29700
7ACFH0063
38500
7ACFH0064
50000
7ACFH0118
77000
7ACFH0180
Combined ON/OFF switch and room thermostat (1) Part nbr
7ACEL0030
7ACEL0041
7ACEL0041
7ACEL0032
7ACEL0032
7ACEL0032
”High Ventilation”
Part nbr
7ACVF0025
7ACVF0023
7ACVF0024
-
-
-
Sum heating resistance
Part nbr
7ACEL0027
7ACEL0029
included
-
-
-
Remote fault reporting kit
Part nbr
-
-
-
7ACEL0072
7ACEL0072
7ACEL0071
Part nbr
-
Body work accessories
Air distribution duct frame
CX 25
X 1100 AO
7ACVF0101
X 1900 AO
7ACVF0102
X 2450 AO
7ACVF0050
X 3250 AO
7ACVF0051
X 4650 AO
7ACVF0052
Total rear air intake duct frame
Part nbr
-
7ACVF0041
7ACVF0104
-
-
-
Front air distribution plenum
Part nbr
7ACVF0112
7ACVF0105
7ACVF0106
7ACVF0108
7ACVF0109
7ACVF0110
New air intake
Part nbr
-
7ACVF0047
7ACVF0047
-
-
-
(1) Combined to be mounted in ambiance.
* Switch assembly to be fitted in the room.
72
X AO Series
X 1100 AO
X 1900 AO
X 2450 AO
X 3250 AO
X 4650 AO
8
2.55
3.14
11.7
3.8
3.08
18
5.8
3.10
23
7.1
3.24
32.4
9.8
3.31
45.7
13.9
3.29
m3/h
m3/h
daPa
dB(A)
1500
1160/1750
8
64
1
2000
1500/2500
20
65
1
3200
2500/3800
25
67
1
4500
3600/5400
20
74
1
5800
4600/7000
25
80
1
9000
7200/10800
25
76
2
Waste water
Flow
Pressure drop
m3/h
kPa
0.34
20
0.58
22
0.92
18
1.45
42
2
40
2.8
18
Recycled water
Flow
Pressure drop
m3/h
kPa
1.17
210
2.1
50
3.4
70
4.3
60
5.8
40
8.3
56
Weight
Dimensions (WxDxH)
Air distribution plenum (height) (1)
kg
mm
mm
125
800x407x1280
300
151
890x430x1540
220
199
1000x500x1735
260
305
1300x600x1840
350
380
1530x600x1840
350
565
1715x790x1970
400
7XU012032
-
-
-
-
-
3N~400 V model - With pressostat water valve Part nbr
7XU012033
7XU012025
7XU012028
7XU012029
7XU012030
7XU012031
3N~400 V model - Without press. water valve Part nbr
-
-
-
7XU012047
7XU012048
7XU012064
Cooling Capacity
Power input
EER
Nominal air flow
Air flow range (min./max.)
Available static pressure (max.)
Acoustic pressure
Number of circuits
CX 25
kW
kW
1~230 V model - With pressostat water valve Part nbr
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power cable section
Fuse rating am
mm2
A
3x2.5
16
-
-
-
-
-
Power supply 3N~400 V
Power cable section
Fuse rating am
mm2
A
5x1.5
3x10
5x1.5
3x12
5x2.5
3x20
5x2.5 / 5x4
3x25
5x6
3x32
5x10
3x50
(1) Plenum in accessories.
73
Industrial
X AO
Vertical cabinet units
Packaged Split-System
Rooftop
DK/DN R407C
DK/DN
Packaged Split-System
11 Cooling Only models from 12 000 to 83 000 W
11 Heat Pump models from 12 400 to 83 800 W
Indoor unit DK 125
Outdoor units DN 405 à 605
DK 205 À 605
> Product advantages
Indoor centrifugal fan units for duct network
connection.
Multi-position architecture for horizontal or
vertical mounting (depending on models).
Versions with factory-fitted ”All Seasons” kit
(Cooling mode operation down to outdoor
temperatures of -10° C).
Outdoor Helicoidal fan units.
Frame and air filter supplied.
CAC Controller: Microprocessor system control and
management.
Scroll compressor.
Phase controller.
Electric heating (accessory).
Centralised regulation with RCW2 remote control
(accessory).
Remote control RCW2
Part number 7ACEL1212
Accessories
Electric heating
74
DK-V 125
DK-V 155
185
205
255
305
405
Capacity (W) 9000
Part number 7ACEL1208
10500
7ACEL1209
12000
7ACEL1184
12000
7ACEL1186
18000
7ACEL1189
18000
7ACEL1176
21000
7ACEL1177
505 & 605 755 & 905
30000
7ACEL1178
30000
7ACEL1340
DK/DN
Cooling Capacity
Power input
EER
Outdoor temperature operating limits
kW 12
kW 4.9
2.5
°C
14.5
5.7
2.5
17.5
6.9
2.5
19.1
7.3
2.6
21
8.6
2.4
28.5
37.5
11.5
14.4
2.5
2.6
-10°/ 46° Dry Bulb *
44
16.7
2.6
56
22.5
2.5
69.1
26.9
2.6
83
33
2.5
Heating Capacity
Power input
COP
Outdoor temperature operating limits
kW 12.4
kW 4.8
2.6
°C
15.7
5.8
2.7
18
6.4
2.8
18.3
6.7
2.7
21
7
3
27.3
36.5
9.3
11.9
2.9
3
-10°/ 19° Dry Bulb
42
14.4
2.9
57.5
22.9
2.5
71
26.4
2.7
83.8
32.4
2.6
DK 185
Horiz.
DK 205
Horiz.
DK 255
Horiz.
DK 305
Horiz.
DK 405
Horiz.
DK 505
Horiz.
DK 605
Horiz.
DK 755
Horiz.
DK 905
Horiz.
3500
2800/
3900
0/20
76
98
1350
x745
x400
4500
3600/
5000
2/21
82
98
1350
x1060
x400
4680
3800/
5100
0/21
82
100
1350
x1060
x400
5760
4600/
6300
0/12
78
150
1690
x991
x676
7560
6000/
8200
0/14
81
160
1690
x991
x676
9360
7500/
10300
3/19
80
205
2100
x1064
x704
9720
7780/
11000
7/20
81
209
2100
x1064
x704
12000
9600/
13200
5/33
84
266
2208
x910
x795
14300
11440/
15730
4/46
88
282
2208
x910
x945
Indoor units DK
Mounting
Nominal air flow
Min./Max. air flow
m3/h
m3/h
Available static pressure (min/max)
Nominal acoustic capacity
Weight
Dimensions (WxDxH)
daPa
dB(A)
kg
mm
DK-V 125 DK-V 155
Horiz.
Vertical
or Vert.
2100
2850
1600/
2100/
2400
3100
0/18
0/11
69
72
69
77
1050
1250
x890
x890
x350
x350
Part number
7SP051152 7SP051151 7SP051069 7SP051141 7SP051142 7SP051143 7SP051144 7SP051145 7SP051146 7SP051122 7SP051123
Outdoor units DN
Flow
Acoustic pressure (GV)
Compressor type
Number of fan
Weight
Dimensions (WxDxH)
DN 125
DN 125 RC
5400
80
Scroll
1
140
746
x746
x909
m3/h
dB(A)
kg
mm
Part number
Part number
DN 185
DN 185 RC
9000
78
Scroll
1
164
900
x800
x1060
DN 205
DN 205 RC
9000
78
Scroll
1
164
900
x800
x1060
DN 255
DN 255 RC
9000
81
Scroll
1
164
900
x800
x1060
DN 305
DN 305 RC
9000
82
Scroll
1
187
1003
x1003
x1094
DN 405
DN 405 RC
2x9000
82
Scroll
2
317
1708
x1123
x972
DN 505
DN 505 RC
2x9000
84
Scroll
2
378
1708
x1123
x1171
DN 605
DN 605 RC
2x9000
87
Scroll
2
405
1708
x1123
x1171
DN 755
DN 755 RC
2x16000
87
Scroll
2
559
2213
x1345
x1304
DN 905
DN 905 RC
2x16000
87
Scroll
2
592
2213
x1345
x1454
3N~400 V model 7SP111061 7SP111054 7SP111055 7SP112013 7SP112014 7SP112015 7SP112016 7SP112017 7SP112018 7SP112137 7SP112146
Fitted with all seasons system 7SP111081 7SP111082 7SP111080 7SP112082 7SP112083 7SP112084 7SP112085 7SP112086 7SP112087 included
Part number
Part number
DN155
DN155 RC
9000
81
Scroll
1
150
900
x800
x1060
included
3N~400 V model 7SP111062 7SP111056 7SP111057 7SP112019 7SP112020 7SP112021 7SP112022 7SP112023 7SP112024 7SP112138 7SP112147
Fitted with all seasons system 7SP111079 7SP111083 7SP111084 7SP112088 7SP112089 7SP112090 7SP112091 7SP112092 7SP112093 included
included
Linking specifications between indoor and outdoor units
Power supply 3N~400 V
Power cable section
Electrical connections
Fuse rating am
mm2 5x2.5
mm2 6x1.5
A 3x16
5x4
6x1.5
3x20
Pipe links
Max. lenght
m 50
50
Max. height
m 50
50
Suction pipe diameter < 20 m
Inches 3/4
7/8
Suction pipe diameter > 20 m
Inches 3/4
3/4
Liquid pipe diameter < 20 m
Inches 1/2
1/2
Liquid pipe diameter > 20 m
Inches 1/2
1/2
* Fitted with all seasons system.
NOTA : From size 205, packaged split system DK/DN are not pre-charged.
5x4
4x1.5
3x25
5x4
4x1.5
3x25
5x4
4x1.5
3x25
5x6
4x1.5
3x32
5x10
4x1.5
3x40
5x16
4x1.5
3x50
5x16
4x1.5
3x63
5x25
4x1.5
3x63
5x35
4x2.5
3x80
50
50
7/8
3/4
5/8
5/8
30
15
1-1/8
1-1/8
1/2
5/8
30
15
1-1/8
1-1/8
1/2
5/8
30
15
7/8
1-1/8
5/8
5/8
30
15
7/8
7/8
1/2
5/8
30
15
7/8
7/8
1/2
5/8
30
15
1-1/8
1-1/8
1/2
5/8
30
15
1-1/8
1-3/8
5/8
5/8
30
15
1-3/8
1-3/8
5/8
5/8
75
Industrial
125
155
185
205
255
305
405
505
605
755
905
125 RC 155 RC 185 RC 205 RC 255 RC 305 RC 405 RC 505 RC 605 RC 755 RC 905 RC
DK/DN Series
Vertical cabinet units
Packaged Split-System
Rooftop
HA
HA
Rooftop units
6 Cooling Only models from de 10 100 to 27 800 W
6 Heat Pump models from 10 100 to 26 500 W
HA unit
> Product advantages
Outdoor installation
Air intake and distribution orifices for connection to a
duct network.
CAC Controller: Microprocessor system control and
management.
RCW 2 wall mounted remote control or dry contact
control (accessory).
Electric heating resistance battery for duct
installation (accessory).
Remote control RCW2
Part number 7ACEL1212
Accessories
Electric heating
HA 35
(1)
Capacity (W)
Part number
(1) Installed inside ducting, inside the building.
6000
7ACEL1216
HA 35
Air filter (air intake)
76
Part number
7ACVF0145
HA 43 & 50
9000
7ACEL1217
HA 43, 50 & 60
7ACVF0146
HA 50, 60, 85 & 95
12000
7ACEL1219
HA 85
7ACVF0147
HA 95
7ACVF0148
HA
HA 43
HA 43 RC
HA 50
HA 50 RC
10.1
4.1
2.46
13.1
5.7
2.30
14.1
5.8
2.43
10.1
3.3
3.06
13.6
5.1
2.67
14.5
5.5
2.64
m3/h
m3/h
1980
1585/2375
2520
2020/3020
3060
2450/3675
daPa
10/15
0/28
dB(A)
dB(A)
73
82
Cooling Capacity
Power input
EER
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power input
COP
Outdoor temperature operating limits
kW
kW
Air flow
Nominal
Min/max.
Available static pressure
Min/max.
Acoustic pressure
Indoor
Outdoor
HA 85
HA 85 RC
HA 95
HA 95 RC
16.8
7.5
2.24
15°/ 46° Dry Bulb
22
9.6
2.29
27.8
12.1
2.30
17.5
6.6
2.65
-10° / 24° Dry Bulb
22.1
8.1
2.73
26.5
9.3
2.85
3600
2880/4320
4680
3745/5615
5760
4610/6915
15/26
13/22
12/23
10/12
73
81
77
84
77
84
79
84
80
85
Reciprocating
1
197
1325x1325x750
Reciprocating
1
210
1325x1325x750
Reciprocating
1
216
1325x1325x750
Reciprocating
1
265
1325x1325x980
Reciprocating
1
310
1325x1325x1200
°C
°C
HA 60
HA 60 RC
Compressor type
Number of compressor
Weight
Dimensions (WxDxH)
kg
mm
Reciprocating
1
140
1095x1150x695
Power supply 3N~400 V
Power cable section
Fuse rating am
mm2
A
5x2.5
3x20
5x2.5
3x25
5x2.5
3x25
5x2.5
3x32
5x4
3x32
5x6
3x32
3N~400 V model
7HL022013
7HL022014
7HL022015
7HL022016
7HL022017
7HL022018
Part nbr 3N~400 V model. Fitted with all seasons system
7HL022085
7HL022075
7HL022097
7HL022098
7HL022079
7HL022089
Part number
3N~400 V model
7HL022019
7HL022020
7HL022021
7HL022022
7HL022023
7HL022024
Part nbr 3N~400 V model. Fitted with all seasons system
7HL022086
7HL022096
7HL022082
7HL022076
7HL022072
7HL022071
Part number
Industrial
HA 35
HA 35 RC
HA Series
77
CHILLED WATER
& HEAT PUMP
RANGE
NEW 2007
VC [email protected] (fan-convectors)
REGULATION [email protected]
AQL/AQH ([email protected])
CWP (heat pump)
> Technological, ecological and adaptable
With a capacity ranging from 1 kW to 90 kW, the Airwell Chilled Water and Heat Pump Range is one of the most competitive
of the market. Its configurations, perfectly adapted to air/water, water/water, helical or centrifugal requirements, can supply
all types of terminal: fan convectors; wall-mounted; cassette-mounted, duct-mounted for residential tertiary areas.
78
[email protected]
p.84
Cassettes
p.86
Ducted/
wall units
p.88
Air/water
chillers
p.90
[email protected]
p.92
Air/water
heat pump
p.94
79
Chilled Water & Heat Pump
Fanconvectors
p.80
Fanconvectors
[email protected]
[email protected]
[email protected]
2 pipes
4 pipes
Cassettes
Ducted
Wall units
[email protected]
Air/water
chillers
Air/water
heat pump
NEW
2 PIPES [email protected]
Fan-convectors
18 models from 1 100 to 13 900 W - 4 Versions
[email protected] AHC
[email protected] AWC
> Product advantages
Ease of installation.
Streamlined design and elaborate finish enabling
harmonious integration.
Air flow rate between 150 and 1500 m3/h.
Series of 2 pipes, 2 pipes/2 wires and 4 pipes.
Accessories
Sizes
10
4 versions, lightened, on chassis, flush-mountable,
Ceiling fixture, on chassis, flush-mountable.
5-speed motor.
Very low operating sound levels.
Aquanet electronic regulation as an accessory.
20
30
40
50
60
70
80
90
W4G1: Regulation valve 1 valve-4 ways
for AWC/AWN
Part number 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0367 7ACFH0367 7ACFH0367
for AHC/AHN
Part number 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0365 7ACFH0365 7ACFH0365
W4G2: Regulation valve 2 valves-4 ways
for AWC/AWN
Part number 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0368 7ACFH0368 7ACFH0368
for AHC/AHN
Part number 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0366 7ACFH0366 7ACFH0366
ELECTROMECHANICAL REMOTE CONTROL (EXCEPT AWC VERSION)
TRM VP: Wall mounted, on/off, winter/summer 3 fan speed, control on valve
TRM-FA: Wall mounted, on/off, winter/summer 3 fan speed, control on fan
CMVM: Manual fan speed selector (4 levels)
Part number 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276
MP: Floor fixing brackets for AWC
for AWC
Part number 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116
for AWN
Part number 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117
BAC: Auxiliary drain tray
Part number 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118
PRC27: Condensate pump AHN
Part number 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360
MPG: Air Intake Grill between feets for AWC & AHC
Part number -
80
7ACTL0119 7ACTL0187 7ACTL0188 7ACTL0189 7ACTL0190 7ACTL0191 7ACTL0192 7ACTL0193
2 PIPES [email protected]
2 pipes [email protected] Series
2030
3030
Cooling Capacity (HS/NS/LS)
Water flow (HS/NS/LS)
Head losses (HS/NS/LS)
kW 1.1/0.95/0.7 2/1.6/1.1
l/h 194/162/122
346/270/187
kPa 19/13/8
43/28/15
2.4/2/1.5
418/367/263
16/12/7
3.5/2.6/2.2
594/450/375
32.5/20/14
Heating capacity (HS/NS/LS)
Water flow (HS/NS/LS)
Head losses (HS/NS/LS)
kW 1.6/1.3/0.9
l/h 194/162/122
kPa 16/11/7
2.7/2.1/1.3
345/270/188
37/23/12
3.4/2.6/1.7
417/367/263
13/11/6
m3/h 166/126/90
dB(A) 40/33/25
292/205/122
45/35/26
AWC Serie - Vertical Console Units with Cabinet
Weight
kg Dimensions (WxDxH)
mm -
20
768x231x478
Part number
70G031577 70G031579 70G031581 70G031583 70G031585 70G031587 70G031589 70G031591
Air flow (HS/NS/LS)
Acoustic pressure (HS/NS/LS)
1030
-
AWN Serie - Vertical Concealed Units without Cabinet
Weight
kg 11
Dimensions (WxDxH)
mm 515x220x430
Part number
14
655x220x430
6030
7030
8030
9030
5/3.3/2.5
861/573/429
29/14/8
5.7/4.4/3.4
983/753/583
42/26/16
6.8/5.6/4
1174/965/673
22/16/8
9/6.6/4.7
1548/1142/814
39/23/12
10.7/9/6.4
1840/1548/1102
38/28/15
4.6/3.5/2.7
594/450/374
28/17/12
6/4.2/3.2
861/572/428
24/12/7
7.4/5.2/4
983/752/583
35/22/14
8.4/6.9/5
1173/965/673
19/13/7
11.3/8.4/5.9
1548/1141/814
33/19/10
13.9/11.5/7.5
1839/1548/1101
33/24/13
374/267/167
48/40/29
524/354/272
44/34/29
677/434/307
47/36/29
843/598/431
53/44/34
984/735/502
53/46/38
1266/859/612
58/48/41
1598/1218/719
62/58/45
23
953x231x478
30
1138x231x478
35
1323x231x478
39
1508x231x478
42
1323x231x578
50
1508x231x578
56
1693x231x578
16
840x220x430
4030
23
1025x220x430
5030
27
1210x220x430
30
1395x220x430
34
1210x220x530
41
1395x220x530
46
1580x220x530
70G031593 70G031595 70G031597 70G031599 70G031601 70G031603 70G031605 70G031607 70G031609
AHC Serie - Ceiling Exposed Units with Cabinet
Weight
kg Dimensions (WxDxH)
mm -
20
768x231x478
Part number
70G031611 70G031613 70G031615 70G031617 70G031619 70G031621 70G031623 70G031625
-
AHN Serie - Ceiling Concealed Units without Cabinet
Weight
kg 11
Dimensions (WxDxH)
mm 572x220x430
Part number
14
712x220x430
23
953x231x478
16
897x220x430
30
1138x231x478
23
1082x220x430
35
1323x231x478
27
1267x220x430
39
1508x231x478
30
1452x220x430
42
1323x231x578
34
1267x220x530
50
1508x231x578
41
1452x220x530
56
1693x231x578
46
1637x220x530
70G031627 70G031629 70G031631 70G031633 70G031635 70G031637 70G031639 70G031641 70G031643
Cooling Capacity (HS/NS/LS)
Water flow (HS/NS/LS)
Head losses (HS/NS/LS)
kW 1.1/0.95/0.7 2/1.6/1.1
l/h 194/162/122
346/270/187
kPa 19/13/8
43/28/15
2.4/2/1.5
418/367/263
16/12/7
3.5/2.6/2.2
594/450/375
32.5/20/14
5/3.3/2.5
861/573/429
29/14/8
5.7/4.4/3.4
983/753/583
42/26/16
6.8/5.6/4
1174/965/673
22/16/8
9/6.6/4.7
1548/1142/814
39/23/12
10.7/9/6.4
1840/1548/1102
38/28/15
Heating capacity (HS/NS/LS)
Water flow (HS/NS/LS)
Head losses (HS/NS/LS)
kW 1.6/1.3/0.9
l/h 194/162/122
kPa 16/11/7
2.7/2.1/1.3
345/270/188
37/23/12
3.4/2.6/1.7
417/367/263
13/11/6
4.6/3.5/2.7
594/450/374
28/17/12
6/4.2/3.2
861/572/428
24/12/7
7.4/5.2/4
983/752/583
35/22/14
8.4/6.9/5
1173/965/673
19/13/7
11.3/8.4/5.9
1548/1141/814
33/19/10
13.9/11.5/7.5
1839/1548/1101
33/24/13
Electrical heating
Air flow (HS/NS/LS)
Acoustic pressure (HS/NS/LS)
W 500
m3/h 166/126/90
dB(A) 40/33/25
750
292/205/122
45/35/26
1200
374/267/167
48/40/29
1500
524/354/272
44/34/29
2000
677/434/307
47/36/29
2400
843/598/431
53/44/34
3000
984/735/502
53/46/38
3600
1266/859/612
58/48/41
4500
1598/1218/719
62/58/45
AWC Serie - Vertical Console Units with Cabinet
Weight
kg Dimensions (WxDxH)
mm -
20
768x231x478
23
953x231x478
30
1138x231x478
35
1323x231x478
39
1508x231x478
42
1323x231x578
50
1508x231x578
56
1693x231x578
Part number
7OG031645 7OG031646 7OG031647 7OG031648 7OG031649 7OG031650 7OG031651 7OG031652
-
AWN Serie - Vertical Concealed Units without Cabinet
Weight
kg 11
Dimensions (WxDxH)
mm 515x220x430
Part number
14
655x220x430
16
840x220x430
23
1025x220x430
27
1210x220x430
30
1395x220x430
34
1210x220x530
41
1395x220x530
46
1580x220x530
7OG031653 7OG031654 7OG031655 7OG031656 7OG031657 7OG031658 7OG031659 7OG031660 7OG031661
AHC Serie - Ceiling Exposed Units with Cabinet
Weight
kg Dimensions (WxDxH)
mm -
20
768x231x478
Part number
7OG031662 7OG031663 7OG031664 7OG031665 7OG031666 7OG031667 7OG031668 7OG031669
-
AHN Serie - Ceiling Concealed Units without Cabinet
Weight
kg 11
Dimensions (WxDxH)
mm 572x220x430
Part number
14
712x220x430
23
953x231x478
16
897x220x430
30
1138x231x478
23
1082x220x430
35
1323x231x478
27
1267x220x430
39
1508x231x478
30
1452x220x430
42
1323x231x578
34
1267x220x530
50
1508x231x578
41
1452x220x530
56
1693x231x578
46
1637x220x530
7OG031670 7OG031671 7OG031672 7OG031673 7OG031674 7OG031675 7OG031676 7OG031677 7OG031678
81
Chilled Water & Heat Pump
2 pipes/2 wires [email protected] Series 1030 E 2030 E 3030 E 4030 E 5030 E 6030 E 7030 E 8030 E 9030 E
Fanconvectors
[email protected]
[email protected]
[email protected]
2 pipes
4 pipes
Cassettes
Ducted
Wall units
Air/water
chillers
[email protected]
Air/water
heat pump
NEW
4 PIPES [email protected]
Fan-convectors
9 models from 1 100 to 14 011 W - 4 Versions
[email protected] AHN
[email protected] AWN
> Product advantages
Ease of installation.
Streamlined design and elaborate finish enabling
harmonious integration.
Air flow rate between 150 and 1500 m3/h.
Series of 2 pipes, 2 pipes/2 wires and 4 pipes.
Accessories
Sizes
10
4 versions, lightened, on chassis, flush-mountable,
Ceiling fixture, on chassis, flush-mountable.
5-speed motor.
Very low operating sound levels.
Aquanet electronic regulation as an accessory.
20
30
40
50
60
70
80
90
W4G1: Regulation valve 1 valve-4 ways
for AWC/AWN
Part number 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0367 7ACFH0367 7ACFH0367
for AHC/AHN
Part number 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0365 7ACFH0365 7ACFH0365
W4G2: Regulation valve 2 valves-4 ways
for AWC/AWN
Part number 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0368 7ACFH0368 7ACFH0368
for AHC/AHN
Part number 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0366 7ACFH0366 7ACFH0366
ELECTROMECHANICAL REMOTE CONTROL (EXCEPT AWC VERSION)
TRM VP: Wall mounted, on/off, winter/summer 3 fan speed, control on valve
TRM-FA: Wall mounted, on/off, winter/summer 3 fan speed, control on fan
CMVM: Manual fan speed selector (4 levels)
Part number 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276
MP: Floor fixing brackets for AWC
for AWC
Part number 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116
for AWN
Part number 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117
BAC: Auxiliary drain tray
Part number 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118
PRC27: Condensate pump AHN
Part number 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360
MPG: Air Intake Grill between feets for AWC & AHC
Part number -
82
7ACTL0119 7ACTL0187 7ACTL0188 7ACTL0189 7ACTL0190 7ACTL0191 7ACTL0192 7ACTL0193
4 pipes [email protected] Series
1031
2031
3031
4031
5031
6031
7031
8031
9031
10.5/8.8/6.2
1804/1512/1069
37/27/14
Cooling Capacity (HS/NS/LS)
Water flow (HS/NS/LS)
Head losses (HS/NS/LS)
kW 1.1/0.9/0.7
l/h 191/158/119
kPa 18/13/8
1.97/1.5/1.1
338/266/184
42/27/14
2.4/2.1/1.5
411/356/256
15/12/7
3.4/2.5/2.1
583/439/367
31/19/14
4.9/3.2/2.4
839/558/418
27/13/8
5.6/4.3/3.3
961/735/569
40/25/16
6.7/5.5/3.8
1145/940/655
21/15/8
8.8/6.5/4.6
1516/1113/792
38/22/12
Heating capacity (HS/NS/LS)
Water flow (HS/NS/LS)
Head losses (HS/NS/LS)
kW 1.4/1.25/1
l/h 126/110/88
kPa 2/2/1
2.5/2.1/1.5
216/184/129
6/4/2
3.3/2.8/2.2
292/246/189
13/9/6
4.5/3.7/3.2
398/327/281
25/17/13
6.3/4.9/3.9
550/428/340
50/32/21
6.6/5.6/4.6
583/493/403
15/11/8
7/6.2/4.7
620/541/414
14/11/7
11.5/9.4/6.7 14/12.3/8.9
1014/828/592
1229/1079/783
48/33/18
73/57/32
283/224/158
45/36/27
362/258/162
48/41/30
508/343/263
44/34/29
656/420/297
47/37/29
817/579/417
53/46/35
953/712/486
53/46/38
1226/832/592
58/49/41
1547/1180/696
62/58/45
AWC Serie - Vertical Console Units with Cabinet
Weight
kg Dimensions (WxDxH)
mm -
20
768x231x478
23
953x231x478
30
1138x231x478
35
1323x231x478
39
1508x231x478
42
1323x231x578
50
1508x231x578
56
1693x231x578
Part number
7OG031578 7OG031580 7OG031582 7OG031584 7OG031586 7OG031588 7OG031590 7OG031592
Air flow (HS/NS/LS)
Acoustic pressure (HS/NS/LS)
m3/h 161/122/87
dB(A) 40/34/26
-
AWN Serie - Vertical Concealed Units without Cabinet
Weight
kg 11
Dimensions (WxDxH)
mm 515x220x430
Part number
14
655x220x430
16
840x220x430
23
1025x220x430
27
1210x220x430
30
1395x220x430
34
1210x220x530
41
1395x220x530
46
1580x220x530
70G031594 70G031596 70G031598 70G031600 70G031602 70G031604 70G031606 70G031608 70G031610
AHC Serie - Ceiling Exposed Units with Cabinet
Weight
kg Dimensions (WxDxH)
mm -
20
768x231x478
Part number
7OG031612 7OG031614 7OG031616 7OG031618 7OG031620 7OG031622 7OG031624 7OG031626
-
AHN Serie - Ceiling Concealed Units without Cabinet
Weight
kg 11
Dimensions (WxDxH)
mm 572x220x430
Part number
14
712x220x430
23
953x231x478
16
897x220x430
30
1138x231x478
23
1082x220x430
35
1323x231x478
27
1267x220x430
39
1508x231x478
30
1452x220x430
42
1323x231x578
34
1267x220x530
50
1508x231x578
41
1452x220x530
56
1693x231x578
46
1637x220x530
70G031628 70G031630 70G031632 70G031634 70G031636 70G031638 70G031640 70G031642 70G031644
83
Chilled Water & Heat Pump
[email protected] 4 PIPES
Fanconvectors
[email protected]
Cassettes
Ducted
Wall units
[email protected]
Air/water
chillers
Air/water
heat pump
[email protected]
[email protected]
Central regulation station
> Product advantages
Window contact.
Multiple configuration.
Compliant with RT2000.
µBMS mini central regulation station
The µBMS surveillance central station was designed to control operation and to monitor the temperature
of individual systems, but also average sized heating, ventilation and air conditioning systems.
It is simple to use and efficiently manages from 1 to 15 different temperature zones.
By simple programming, the user can change the set temperature values of heating and cooling modes,
select the ventilation speed for each of the areas monitored by his mini surveillance central station.
This central station makes it possible to individually monitor the following functions in each of the zones by
means of a single RS 385 communication bus (2 twisted and shielded wires):
• A programming including on/off or sleep, the time and day of the week, the operating mode,
the ventilation speed (Lo, Me, Hi, Auto), and temperature settings.
This programming selects the time ranges.
- Either individually (for each zone) for 2 time ranges.
- Or globally (for all zones) for 2 time ranges.
• A comfort (occupancy)/economy (vacant) function.
• An anti-frost function for heating mode.
• A ventilation flap control function.
Electronic controls
Type of device
AWC
AWN
AHC
Wall-mounted RCL (kit)
•
•
•
AHN
•
Device mounted RCL
•
•
-
-
Electronic regulators
AquaNet system A = 2 Pipes
AquaNet system B = 2 Reversible Pipes (with pipe probe) (4-way valve mandatory)
AquaNet system C = 2 Pipes/2 Wires (2 electrical stages) (1)
AquaNet system D = 2 Reversible Pipes + Additional electric power (3 Heating stages : heating valve + 2 electric stages) (1)
(4-way valve mandatory)
AquaNet system E = 4 Pipes
(1) Second heating stage with electric battery on option, see tarif.
Regulation and communication accessories
Auxiliary board for communication via NIU bus (factory mounted)
µBMS central surveillance station (100 units and 15 zones)
[email protected] control board
ATTENTION: products configured per requirements. Specify the type of system desired in the order.
(A, B, C, D, E), the type of RCL control desired (built-in or remoted), the accessories.
84
[email protected]
ELECTRONIC REGULATION INFORMING ON WATER AND AIR
RCL control (built into the unit or remoted)
Electronic regulation for the [email protected] was specially developed for fan convectors of the lightened, ceiling fixture
or cassette type, with total recycled air for applications relating to 2 cooling pipes alone, 2 heating pipes alone,
2 pipes/2 wires, 2 reversible pipes with or without additional electric power and 4 pipes. It consists of an FCC
regulator built into the fan convector and an RCL control that can be installed on option on our range of
lightened type fan convectors.
[email protected] is a new generation of regulation units operating with a proprietary communication bus by means of
an additional board that is very simple to install and a supervision central station called µBMS. For small
systems, this regulation also makes it possible to very easily set up a master/slave wire link network to
monitor up to 15 devices with a single RCL control.
The [email protected] electronic regulation was designed to provide an excellent trade-off between cost (thermal
valve for integral proportional regulation), ergonomics and performance.
It is compatible with the µBMS supervision central station and communicates over the proprietary bus; it can
however also operate without the supervision central station. The [email protected] regulation enables adaptation to the
following air conditioner models:
MODEL A : For fan convectors with 2 heating or cooling pipes alone with manual changeover.
MODEL B : For fan convectors with 2 reversible pipes with automatic changeover (pipe probe).
MODEL C : For fan convectors with 2 pipes/2 wires.
MODEL D : For fan convectors with 2 reversible pipes with automatic changeover (pipe probe) and additional electric power
for heating and cooling.
MODEL E : For fan convectors with 4 pipes.
FCC regulator (built into the unit)
The [email protected] regulation fully controls operation of the fan convector, by switching on or shutting down as a
function of the temperature setting, automatic or manual engagement of the ventilation speeds, control of the
heating or cooling valve in timed mode proportional to the PI algorithm, and an integral proportional control on
the two electric heating stages.
In its standard configuration, the [email protected] regulation integrates additional functions for an individual control or
for controlling several zones of fan convectors:
• comfort function (occupancy) / economy function (vacant),
• window contact with activation of anti-frost mode,
• keypad locking,
• operation as master/slave of up to 15 units, from a single remote control.
Simple-to-use regulation system, no programming of regulators being necessary.
System easy to install, the [email protected] regulation is installed, wired and configured in the factory.
Individual item regulation system, simple to use, for one zone or multiple zones via the communication bus.
Upgradable regulation system, steered by a mini supervision central station ensuring automatic and weekly
management of operating time ranges, temperature settings
for each area, and this for 15 different zones.
> Product advantages
Plug and play.
Factory wired.
Possibility of Master/Slave operation.
Occupancy/vacant mode management.
Additional board
[email protected] network architecture
Mini supervision
central station
TEMP
MODE
TIMER
SET
NIGHT
+
HOUR
CLEAR
-
SWING
RS485 bus
FCC
FCC
up to
15 units
RCL
up to
100 units
FCC
up to
15 units
RCL
up to
15 units
RCL
85
Chilled Water & Heat Pump
SWING
Fanconvectors
[email protected]
Cassettes
Ducted
Wall units
K OG
K OG
2 pipes
4 pipes
Air/water
chillers
[email protected]
Air/water
heat pump
2 & 4 PIPES K OG
Chilled Water Cassettes
5 models - 2 pipes from 2 330 to 10 200 W
4 models - 4 pipes from 2 200 to 10 600 W
K OG 30/45
K OG 9/12/18
> Product benefits
Designed for suspended ceiling integration.
600 x 600 and 600 x 1200 formats (30 and 45 models).
Low built-in height: 287 mm.
Direct access to electrical connections on sliding
chassis.
Integrated valves and electrical connections.
K 9 OG
2 Pipes Accessories
Heating/Cooling thermostat
Part nbr 7ACEL1161
Manual ON/OFF- 3 fan speed (KOG 2T CH AV version)
New air intake.
Air distribution to a separate room.
Integrated condensate drainage lift pump.
Infrared remote control version with valve and
changeover.
Solid ceiling frame (accessory).
K 12 OG
K 18 OG
K 30 OG
K 45 OG
7ACEL1161
7ACEL1161
7ACEL1161
7ACEL1161
Heating/Cooling thermostat
Part nbr 7ACEL1386
7ACEL1386
Manual ON/OFF- 3 fan speed (KOG 2T AV version) with sonde of change over
7ACEL1386
7ACEL1386
7ACEL1386
Heating/Cooling thermostat
Part nbr 7ACEL1388
7ACEL1388
7ACEL1388
Manual ON/OFF- 3 fan speed (KOG 2T CH AV version) change over sensor and electric heating relay
7ACEL1388
7ACEL1388
Heating/Cooling thermostat
Part nbr 7ACEL1373
Manual ON/OFF- 3 fan speed - without valve (KOG 2T SV version)
7ACEL1373
7ACEL1373
7ACEL1373
7ACEL1373
Special Frame for solid ceilings
Part nbr
7ACVF0091
7ACVF0091
7ACVF0091
-
-
Relay kit for chilled water cassettes (4 units) Part nbr
7ACEL1207
7ACEL1207
7ACEL1207
7ACEL1207
7ACEL1207
3 way heating valve/ 2 pipes + condensate tray
Part nbr
-
-
-
7ACFH0051
7ACFH0052
Condensate
Part nbr
-
-
-
7ACTL0005
7ACTL0005
K 9 OG
4 Pipes Accessories
K 12 OG
K 18 OG
K 45 OG
Heating/Cooling thermostat
Part number 7ACEL1161
Manual ON/OFF- 3 fan speed (KOG 4T AV version) with sonde of change over
7ACEL1161
7ACEL1161
7ACEL1161
Special Frame for solid ceilings
Part number
7ACVF0091
7ACVF0091
7ACVF0091
-
Relay kit for chilled water cassettes (4 units)
Part number
7ACEL1207
7ACEL1207
7ACEL1207
7ACEL1207
3 way heating valve/ 4 pipes + condensate tray
Part number
-
-
-
7ACFH0122
Condensate (4 pipes)
Part number
-
-
-
7ACTL0040
86
2 & 4 PIPES K OG
2 pipes KOG Series
K 9 OG
K 12 OG
K 18 OG
K 30 OG
K 45 OG
Cooling Capacity
kW
2.33
3.5
5
6.44
10.2
Heating Capacity
Power Input
Electrical Heating (Factory option)
kW
kW
kW
3.4
0.06
1.5
4.6
0.08
2.25
5.9
0.11
2.7
8.05
0.20
4.2
11.6
0.22
5.4
420/460/700
0.378
12.5
37/40/50
25
571x571x287
625x625x40
420/460/700
0.602
17.5
38/41/51
28
571x571x287
625x625x40
460/515/760
0.86
15
44/49/57
29
571x571x287
625x625x40
1100/1350/1550
1.208
17
51/54/57
49
1171x571x287
1225x625x40
1000/1250/1630
1.753
23.5
50/54/60
55
1171x571x287
1225x625x40
3x1
1
3x1.5
10
3x1
1
3x1.5
16
3x1
1
3x1.5
16
3x1.5
2
3x4
25
3x1.5
2
3x2.5
25
Indoor units
Air flow (LS/NS/HS)
Water flow
Water pressure drop
Acoustic power to 1m (LS/NS/HS)
Weight
Built in casing (WxDxH)
Frame (WxDxH)
m3/h
m3/h
kPa
dB(A)
kg
mm
mm
Power supply 1~230 V
Power cable section (without heating)
Fuse rating am (without heating)
Power cable section (with heating)
Fuse rating am (with heating)
mm2
A
mm2
A
Version without valve
Part number
1~230 V model
K9 OG 2T SV
7OG051008
K12 OG 2T SV
7OG051012
K18 OG 2T SV
7OG051016
K30 OG 2T SV
7SP041036
K45 OG 2T SV
7SP041037
Version with valve
Part number
1~230 V model
K9 OG 2T AV
7OG051009
K12 OG 2T AV
7OG051013
K18 OG 2T AV
7OG051017
-
-
Electrical Heating version without valve
Part number
1~230 V model
K9 OG 2T CH SV
7OG051010
K12 OG CH 2T SV
7OG051014
K18 OG CH 2T SV
7OG051018
K30 OG CH 2T SV
7SP041020
K45 OG CH 2T SV
7SP041025
Electrical Heating version with valve
Part number
1~230 V model
K9O G 2T CH AV
7OG051011
K12 OG 2T CH AV
7OG051015
K18 OG 2T CH AV
7OG051019
-
-
Infrared version with valve and change over
Part number
1~230 V model
K9 OG 2T IR AV
7OG101010
K12 OG 2T IR AV
7OG101011
-
K30 OG 2T IR AV
7OG101013
K45 OG 2T IR AV
7OG101014
K 18 OG
K 45 OG
K 9 OG
4 pipes KOG Series
K 12 OG
Cooling Capacity
kW
2,2
3,43
4,9
10,6
Heating Capacity
Power Input
kW
kW
2,2
0,06
3,2
0,08
4,9
0,11
9,25
0,22
420/460/700
0,378
0,19
12
37/40/50
25
571x571x287
625x625x40
420/460/700
0,59
0,275
17
40/42/52
28
571x571x287
625x625x40
320/460/515/760
0,843
0,421
17,5
42/48/57
29
571x571x287
625x625x40
1075/1360/1725
1,825
0,49
28,6
48/54/60
55
1171x571x287
1225x625x40
10
16
16
-
Indoor units
Air flow (LS/NS/HS)
Cold Water flow
Hot Water flow
Water pressure drop
Acoustic power to 1m (LS/NS/HS)
Weight
Built in casing (WxDxH)
Frame (WxDxH)
m3/h
m3/h
m3/h
kPa
dB(A)
kg
mm
mm
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Fuse rating am
Linking pipes
Suction 4 pipes diameter
Version without valve
Part number
Version with valve
Part number
A
Inches
1/2’’
1/2’’
1/2’’ hot/3/4’’ cold
1/2’’ hot/1’’ cold
1~230 V model
K9 OG 4T SV
7OG051020
K12 OG 4T SV
7OG051022
K18 OG 4T SV
7OG051024
K45 OG 4T SV
7SP041024
1~230 V model
K9 OG 4T AV
7OG051021
K12 OG 4T AV
7OG051023
K18 OG 4T AV
7OG051025
K45 OG 4T AV
-
87
Chilled Water & Heat Pump
Linking specifications between indoor and outdoor units
Fanconvectors
[email protected]
Cassettes
Ducted
Air/water
chillers
[email protected]
Air/water
heat pump
VHF
2 pipes
VHF
Ducted units
4 models - 2 pipes from 3 300 to 11 900 W
VHF
> Product benefits
Indoor units compatible with AIRWELL chilled water
production units.
Compact dimensions and low built-in height (231 mm
for the VHF 01A model).
Available static pressure.
Designed for suspended ceiling integration with a
duct network.
Integrated air intake plenum, 200 mm diameter outlets.
Integrated air distribution plenum, 200 mm diameter
outlets.
New air intake, 100 mm diameter.
3 fan (ventilation) speeds.
Low noise levels.
Air filter, G2 (80% gravimetry) reusable synthetic
material.
Easy access to electrical and hydraulic connections
on the right side of the unit.
Easy air filter access via the underside of the unit.
Electric heating available as a factory-fitted option
(on request): • VHF 01A: 1,000 W
• VHF 05A: 1,500 W
• VHF 10 and 12A: 3,600 W
VHF01A
2 pipes VHF Series
VHF05A
VHF10A
VHF12A
Cooling Capacity
kW
2.9
4.9
7.4
9.4
Heating Capacity
Power Input
kW
kW
3.3
0.19
4.8
0.13
6.2
0.27
11.9
0.24
m3/h
m3/h
kPa
kg
mm
from 100 to 550 m3/h
0.5
17
21
600x695x200
from 300 to 700 m3/h
0.84
22
46
1062x918x231
from 400 to 1000 m3/h
1.27
44
55
1202x918x253
from 700 to 1500 m3/h
1.63
39
59
1202x918x301
mm2
A
3x1.5
1
3x1.5
1
3x1.5
2
3x1.5
2
7OG041030
7OG041031
7OG041032
7OG041033
Indoor units
Air flow
Water flow
Water pressure drop
Weight
Dimensions (WxDxH)
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power cable section
Fuse rating am
Part number
88
1~230 V model - Version without valve
[email protected]
Fanconvectors
Cassettes
Wall units
Air/water
chillers
[email protected]
Air/water
heat pump
XLM OG
2 pipes
XLM OG
Chilled Water wall mounted units
4 models - 2 pipes from 3 300 to 11 900 W
XLM OG 18
XLM OG 7/9
> Product benefits
Indoor units compatible with AIRWELL chilled water production units.
Compact and lightweight design for easy installation and maintenance.
Available with or without flow regulation valve.
Hard-wired controls (with or without regulation valve).
2 pipes XLM OG Series
XLM 7 OG
XLM 9 OG
XLM 18 OG
Cooling Capacity
kW
1.85
2.2
3.5
Heating Capacity
Power Input
Electrical Heating
kW
kW
kW
2.25
0.1
1.05
3.3
0.1
-
4.6
0.2
1.6
220/290/360
43/45/49
0.32
12
8
815x160x270
280/370/450
50/52/53
0.38
15
9.5
815x160x270
600/740/860
52/56/57
0.5
17
14
1115x195x330
3x1.5
1
6
3x1.5
1
-
3x1.5
2
10
Thermostat version TRM-FA, without valve
Part number
1~230 V model
XLM 7 OGSV
7SP022027
XLM 9 OGSV
7SP022028
XLM 18 OGSV
7OG061010
Thermostat version TRM-VP, without valve
Part number
1~230 V model
XLM 7 OGAV
7OG061098
XLM 9 OGAV
7OG061099
XLM 18 OGAV
7OG061100
Thermostat version TAE20, electric heating with valve
Part number
1~230 V model
XLM 7 OGAVCH
7OG061013
-
XLM 18 OGAVCH
7OG061008
Indoor units
Air flow (LS/NS/HS)
Acoustic power
Water flow
Water pressure drop
Weight
Dimensions (WxDxH)
m3/h
dB(A)
m3/h
Pa
kg
mm
Power supply
Power cable section
Fuse rating am (without electric heating)
Fuse rating am (with electric heating)
mm2
A
A
89
Chilled Water & Heat Pump
Linking specifications between indoor and outdoor units
Fanconvectors
[email protected]
Cassettes
Ducted
Wall units
Air/water
chillers
[email protected]
Air/water
heat pump
MQL/MQH
MQL/MQH
Air/water chillers
7 Cooling Only models from 4 500 to 16 500 W (MQL)
7 Heat Pump models from 5 000 to 18 800 W (MQH)
MQH 04/06/08
MQL 04/06/08
MQH 10/12/15/17
MQL 10/12/15/17
> Product benefits
Single-phase units up to size 10.
Microprocessor controlled operation.
µLTC regulation (self-adapting set temperature
point, fan (ventilation) speed control…)
Reduced water volume (3.5 litres/ kW).
Ready to install unit.
MQL 04
MQH 04
MQL 06
MQH 06
MQL 08
MQH 08
MQL 10
MQH 10
MQL 12
MQH 12
MQL 15
MQH 15
MQL 17
MQH 17
Part number 7ACEL1188
7ACEL1188
7ACEL1188
7ACEL1188
7ACEL1188
7ACEL1188
7ACEL1188
Accessories
Remote control with cable
3 pump speeds.
Average COP: 4.1.
Average EER: 3.1.
Low noise levels.
Numerous accessories (start-up current draw regulator,
low temperature operation kit, buffer tank).
Isolating valve with pressure kit Part number 7ACFH0423
7ACFH0423
7ACFH0423
7ACFH0423
7ACFH0423
7ACFH0423
7ACFH0423
Water filter
Part number 7ACFH0278
7ACFH0278
7ACFH0278
7ACFH0278
7ACFH0278
7ACFH0278
7ACFH0278
Water Tank 15 l
Part number 7ACFH0486
7ACFH0486
7ACFH0486
-
-
-
-
Water Tank 30 l
Part number -
-
-
7ACFH0484
7ACFH0484
7ACFH0484
7ACFH0484
MQL 04
MQL 06
MQL 08
MQL 10
MQL 12
MQL 15
MQL 17
Low ambiant kit (- 5 °C)
Part number 7ACFH0475
7ACFH0475
7ACFH0475
7ACFH0475
7ACFH0475
7ACFH0475
7ACFH0475
90
MQL/MQH
MQL 04
MQH 04
MQL/MQH Series
MQL 06
MQH 06
MQL 08
MQH 08
MQL 10
MQH 10
MQL 12
MQH 12
MQL 15
MQH 15
MQL 17
MQH 17
Cooling Capacity
Power Input
EER
Operating limits outdoor temperature
Outlet water temperature
kW 4.5
kW 1.5
3.0
°C
°C
5.9
1.9
3.1
8.1
2.7
3.0
10.5
3.3
3.2
10°/ 46°
5°/ 18°
12.1
4.0
3.0
14.9
4.6
3.2
16.5
5.2
3.2
Heating Capacity (1)
Power Input
COP
Operating limits outdoor temperature
Outlet water temperature
kW 5
kW 1.2
4.2
°C
°C
6.7
1.6
4.2
9.1
2.6
3.5
10.5
2.8
3.8
-5°/ 15°
30°/ 50°
13.1
3.3
4.0
17.4
3.80
4.6
18.8
4.30
4.4
40
Rotary
104
1182x400x905
41
Scroll
110
1182x400x905
43
Scroll
153
1182x400x1309
44
Scroll
158
1182x400x1309
45
Scroll
160
1182x400x1309
45
Scroll
166
1182x400x1309
Stainless stell plate
Stainless stell plate
Stainless stell plate
Stainless stell plate
Stainless stell plate
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
mm2 3x2.5
A 16
3x2.5
16
3x4
25
3x4
25
-
-
-
mm2 A -
-
5x2.5
3x16
-
-
-
-
1~230 V model 7OG012170
7OG012171
7OG012172
7OG012132
-
-
-
1~230 V model - Avec Softstarter 7OG012178
7OG012179
7OG012180
7OG012144
-
-
-
-
7OG012173
7OG012133
7OG012134
7OG012135
7OG012136
Static pressure at 5 m
Compressor type
Weight
Dimensions (WxDxH)
Exchanger type
dB(A) 40
Rotary
kg 97
mm 1182x400x905
Stainless stell plate Stainless stell plate
Water circuit links
Inlet
Outlet
Inches 1”
Inches 1”
Linking specifications between indoor and outdoor units
Power cable section
Fuse rating am
Power supply 3N~400 V
Power cable section
Fuse rating am
Part number
Part nbr
Part number
Part number
Part nbr
3N~400 V model 1~230 V model 7OG012174
7OG012175
7OG012176
7OG012137
-
-
-
1~230 V model - Avec Softstarter 7OG012181
7OG012182
7OG012183
7OG012145
-
-
-
-
7OG012177
7OG012138
7OG012139
7OG012140
7OG012141
Part number
3N~400 V model -
(1) Conditions: 7 °C outdoor, 35 °C outlet water.
91
Chilled Water & Heat Pump
Power supply 1~230 V
Fanconvectors
[email protected]
Cassettes
Ducted
Wall units
[email protected]
Air/water
chillers
NEW
Air/water
heat pump
AQL/AQH
[email protected] AQL/AQH
Fluid coolers with condensation by air
and reversible air-water heat pumps
9 Cooling Only models from 21 500 to 75 000 W (AQL)
9 Heat Pump models from 24 000 to 87 400 W (AQH)
AQH 80
AQH 20
AQH 40
> Product advantages
Choice from 10 sizes.
Compatible with Water Chilled Airwell terminal units
and heating-cooling floor.
Tandem Scroll compressor in standard version.
Plug and play design, unit ready to operate.
Self-adapting regulation with ILTC microprocessor.
AQL 20
AQH 20
Accessories
AQL 25
AQH 25
Power savings.
Low operating sound level.
Brazed plate heat exchanger.
High-performance axial fan with external rotor.
Easy access to components provided by
removable panels.
AQL 30
AQH 30
AQL 35
AQH 35
AQL 40
AQH 40
AQL 50
AQH 50
AQL 60
AQH 60
AQL 70
AQH 70
AQL 80
AQH 80
Isolating valve
Part number 7ACFH0345
7ACFH0345
7ACFH0345
7ACFH0345
7ACFH0345
7ACFH0345
7ACFH0345
7ACFH0345
7ACFH0345
Additional water tank 112 l
Part number 7ACFH0346
7ACFH0346
7ACFH0346
7ACFH0346
-
-
-
-
-
Additional water tank 224 l
Part number -
-
-
-
7ACFH0347
7ACFH0347
-
-
-
Additional water tank 294 l
Part number -
-
-
-
-
-
7ACFH0348
7ACFH0348
7ACFH0348
92
[email protected]
AQL/AQH
AQL 20
AQH 20
AQL/AQH Series
AQL 25
AQH 25
AQL 30
AQH 30
AQL 35
AQH 35
AQL 40
AQH 40
AQL 50
AQH 50
AQL 60
AQH 60
AQL 70
AQH 70
AQL 80
AQH 80
Cooling capacity(2)
Power input with pump
Power input
EER
Outdoor temperature operating limits
Outlet water temperature Min/Max.
kW 21.5
kW 8.4
kW 7.6
3.0
°C
°C
26
10
9.2
3.0
29.9
11.4
10.6
3.0
34.2
12.2
11.4
2.9
39.5
16.1
15.4
2.9
-10°/ 46°
5°/ 18°
47.9
19.4
18.7
2.6
55.9
23.9
22.8
2.7
67
28.1
27
2.7
75
30.7
29.6
2.7
Heating capacity(1)
Power input with pump
Power input
COP
Outdoor temperature operating limits
Outlet water temperature Min/Max.
kW 24
kW 7.2
kW 6.4
3.8
°C
°C
29
8.3
7.5
3.9
34.2
9.5
8.7
3.9
38.3
9.3
8.5
4.5
46.3
13.5
12.7
3.6
-10°/ 20°
25°/ 50°
57.7
16
15.2
3.8
68.9
19.9
18.8
3.7
80.5
23.8
22.7
3.5
87.4
26
24.9
3.5
11200
59
11200
60
11200
60
11200
61
15500
67
21000
70
21000
70
2/2
70
30/10
35
1.67
5
2/2
50
30/10
35
2.2
5
2/2
50
30/10
35
2.44
5
286
271
1477x516x1607
296
281
1477x516x1607
mm2 5x6
A 25
Inches 1”1/2
Air flow max (HS)
m3/h
Acoustic pressure at 1 m
dB(A)
Compressor type
Quantity vs capacity reduction stages
Min. power
%
Max. pressure on refrigerant side/ on water side bar
Anti-freezing heating element
W
Water volume
l
Expansion valve
l
Water pump
Weight with pump
kg
Weight without pump
kg
Dimensions (WxDxH)
mm
2/2
36
30/10
35
5.33
12
2/2
45
30/1030/10
35
6.33
12
2/2
50
306
291
1477x516x1607
15500
15500
65
65
Hermetic Scroll
2/2
2/2
2/2
50
45
36
30/10
30/10
30/10
35
35
35
2.44
3.44
4.33
5
12
12
Centrifugal pump monospeed
305
510
585
290
490
565
1477x516x1607 1737x1201x1634 1737x1201x1634
590
570
2168x1201x1634
620
600
2168x1201x1634
640
620
2168x1201x1634
5x10
32
5x10
32
5x10
40
5x16
50
5x16
50
5x25
63
5x25
63
5x25
80
1”1/2
1”1/2
1”1/2
2”
2”
2”
2”
2”
35
7.10
12
Power supply 3N~400 V
Power cable section
Fuse rating am
Hydraulic connection
Diameter
Part nbr
Basic model 3N~400 V 7OG021001
7OG021002
7OG021003
7OG021004
7OG021005
7OG021006
7OG021007
7OG021008
7OG021009
Part nbr
Pack model with single pump 3N~400 V 7OG021015
7OG021016
7OG021017
7OG021018
7OG021019
7OG021020
7OG021021
7OG021022
7OG021023
Part nbr
Basic model 3N~400 V 7OG021029
7OG021030
7OG021031
7OG021032
7OG021033
7OG021034
7OG021035
7OG021036
7OG021037
Part nbr
Pack model with single pump 3N~400 V 7OG021043
7OG021044
7OG021045
7OG021046
7OG021047
7OG021048
7OG021049
7OG021050
7OG021051
(1) Values based on inlet/outlet chilled water temperatures from 30/35° and 7°C outside.
(2) Values based on inlet/outlet chilled water temperatures from 12/7° and 35°C outside.
93
Chilled Water & Heat Pump
Linking specifications between indoor and outdoor units
Fanconvectors
[email protected]
Cassettes
Ducted
Wall units
[email protected]
Air/water
chillers
Air/water
heat pump
CWP
CWP
NEW
Fluid coolers with condensation by water – Reversible heat pumps
7 Cooling Only models from 7 600 to 33 700 W
7 Heat Pump models from 9 000 to 40 100 W
CWP
> Product advantages
Compatible with Water Chilled Airwell terminal
units and heating-cooling floor.
Electronic regulation.
Digital display panel.
Accessories
Indoor installation (equipment rooms, etc.).
Plate type evaporator.
Brazed stainless steel plate type condenser.
Environmentally sealed Scroll compressor.
CWP 02
CWP 03
CWP 04
CWP 05
CWP 06
CWP 07
CWP 09
CWP HP02 CWP HP03 CWP HP04 CWP HP05 CWP HP06 CWP HP07 CWP HP09
Isolation valve kit VI
Part nbr 7ACFH0371
7ACFH0371
7ACFH0371
7ACFH0371
7ACFH0371
7ACFH0371
7ACFH0371
Water flow controller CD
Part nbr 7ACFH0372
7ACFH0372
7ACFH0372
7ACFH0372
7ACFH0372
7ACFH0372
7ACFH0372
Water lack pressure switch PME
Part nbr 7ACFH0373
7ACFH0373
7ACFH0373
7ACFH0373
7ACFH0373
7ACFH0373
7ACFH0373
HP / LP pressure gauges MHPBP Part nbr 7ACFH0374
7ACFH0374
7ACFH0374
7ACFH0374
7ACFH0374
7ACFH0374
7ACFH0374
Water filter kit FE
Part nbr 7ACFH0375
7ACFH0375
7ACFH0375
7ACFH0375
7ACFH0375
7ACFH0375
7ACFH0375
Rubber studs PC
Part nbr 7ACTL0186
7ACTL0186
7ACTL0186
7ACTL0186
7ACTL0186
7ACTL0186
7ACTL0186
Fault return relay RRD
Part nbr 7ACEL1278
7ACEL1278
7ACEL1278
7ACEL1278
7ACEL1278
7ACEL1278
7ACEL1278
Pressostatic valve VP1
Part nbr 7ACFH0376
7ACFH0376
7ACFH0376
-
-
-
-
Pressostatic valve VP2
Part nbr -
-
-
7ACFH0377
7ACFH0377
7ACFH0377
7ACFH0377
Control transformer TC
Part nbr -
7ACEL1277
7ACEL1277
7ACEL1277
7ACEL1277
7ACEL1277
7ACEL1277
94
CWP
CWP Series
Compressor type
Weight
Dimensions (LxPxH)
kW 7.6
kW 1.97
3.9
CWP 03
9.2
2.38
3.9
CWP 04
13.3
3.37
3.9
CWP 05
16.3
3.91
4.2
CWP 06
19.7
5.08
3.9
CWP 07
28
7.16
3.9
CWP 09
33.7
8.8
3.8
Scroll
kg 115
119
125
138
185
197
201
mm 800x600x910 800x600x910 800x600x910 800x600x910 900x700x910 900x700x910 900x700x910
Evaporator
Capacity
Input connection
Output connection
l 0.7
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.7
1-1/4
1-1/4
1.7
1-1/4
1-1/4
2.2
1-1/4
1-1/4
2.2
1-1/4
1-1/4
Condenser
Capacity
Input connection
Output connection
l 0.7
1-1/4
1-1/4
0.7
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.7
1-1/4
1-1/4
1.7
1-1/4
1-1/4
2.2
1-1/4
1-1/4
-
-
-
-
-
-
7OG091020
7OG091021
7OG091022
7OG091023
7OG091024
7OG091015
Part number
Part number
CWP HP Series
Model 1~230 V 7OG091019
Model 3N~400 V -
CWP HP02 CWP HP03 CWP HP04 CWP HP05 CWP HP06 CWP HP07 CWP HP09
Cooling capacity (2)
Power input
EER
kW 6.5
kW 2.58
2.50
7.9
2.97
2.70
11.5
4.33
2.70
14.2
5.06
2.80
17.1
6.51
2.60
24.4
9.21
2.70
29.4
11.2
2.60
Heating capacity (2)
Power input
COP
kW 9
kW 2.58
3.50
10.7
2.97
3.60
15.7
4.33
3.60
19
5.06
3.80
23.3
6.51
3.60
33.2
9.21
3.60
40.1
11.2
3.60
Compressor type
Weight
Dimensions (LxPxH)
Scroll
kg 127
130
137
151
204
216
222
mm 800x600x910 800x600x910 800x600x910 800x600x910 900x700x910 900x700x910 900x700x910
Evaporator
Capacity
Inlet connection
Outlet connectione
l 0.7
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.7
1-1/4
1-1/4
1.7
1-1/4
1-1/4
2.2
1-1/4
1-1/4
2.2
1-1/4
1-1/4
Condenser
Capacity
Inlet connection
Outlet connection
l 0.7
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.1
1-1/4
1-1/4
1.7
1-1/4
1-1/4
1.7
1-1/4
1-1/4
2.2
1-1/4
1-1/4
2.2
1-1/4
1-1/4
-
-
-
-
-
-
7OG091002
7OG091003
7OG091004
7OG091017
7OG091018
7OG091016
Part number
Part number
Model 1~230 V 7OG091001
Model 3N~400 V -
(1) Values based on chilled water temperatures of 12/7° C and condenser water temperatures of 29/35° C.
(2) Values based on chilled water temperatures of 12/7° C and condenser water temperatures of 40/46° C.
Chilled water outlet temperature
Chilled water temperature difference
Condenser water outlet temperature
Condenser water temperature difference
Condenser water inlet temperature without pressostatic valve
Condenser water inlet temperature with pressostatic valve
Mini
5 °C
4 °C
26 °C
5 °C
20 °C
15 °C
Maxi
15 °C
6 °C
51 °C
7 °C
45 °C
36 °C
95
Chilled Water & Heat Pump
Cooling capacity
Power input
EER
CWP 02
(1)
ACCESSORIES
Ivory dual flare
Linking pipes
Part number
Name
7ACFH0023
Dual Flare link insulated M1 1/4 & 3/8 - 2,5 ml
7ACFH0026
Dual Flare link insulated M1 1/4 & 1/2 - 2,5 ml
7ACFH0032
Dual Flare link insulated M1 3/8 & 5/8 - 2,5 ml
7ACFH0334
Dual Flare link insulated M1 3/8 & 3/4 - 2,5 ml
7ACFH0024
Dual Flare link insulated M1 1/4 & 3/8 - 5 ml
7ACFH0027
Dual Flare link insulated M1 1/4 & 1/2 - 5 ml
7ACFH0033
Dual Flare link insulated M1 3/8 & 5/8 - 5 ml
7ACFH0335
Dual Flare link insulated M1 3/8 & 3/4 - 5 ml
7ACFH0025
Dual Flare link insulated M1 1/4 & 3/8 - 8 ml
7ACFH0028
Dual Flare link insulated M1 1/4 & 1/2 - 8 ml
7ACFH0034
Dual Flare link insulated M1 3/8 & 5/8 - 8 ml
7ACFH0464
Dual Flare link insulated M1 3/8 & 3/4 - 8 ml
Wall brackets
Part number
Name
7ACTL0016
Wall bracket for models: 7/9/12/14/15
7ACTL0018
Wall bracket for models: 18/24/30
7ACTL0013
Wall bracket for models: 36/45
RC4
RC5
RC7
RCW2
Electrical accessories
Part number
96
Name
436670
R/C-4
All models (except PNX DCI, FLO DCI, PNX, FLO N)
452760600
R/C-4 (H L)
Remote control for PNX DCI, FLO DCI, PNX, FLO N
453042500
R/C-4I-1
Remote control for Florida 30/36
412040
RC-5
Remote control for AELIA/ALASKA
4527178
RC-7
Remote control for DAKOTA WDI
7ACEL1212
RCW2 Wall remote control
7ACEL1249
RCW2 connection kit for FLO
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement