Whirlpool GJD3044R Cooktop User manual

® Electric Built-in Ceramic Downdraft Cooktop PRODUCT MODEL NUMBERS OVERALL DIMENSIONS GJD3044R 30-3/8" (77.1 cm) - 30" (76.2 cm) models 36-3/8" (92.3 cm) - 36" (91.4 cm) models width 21-5/16" (54.1 cm) depth Electrical: A four-wire or three-wire, singlephase, 240-volt, 60-Hz, AC-only electrical supply is required on a separate 30-ampere circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connected directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with ground wire). Flexible armored cable should connect cooktop directly to the junction box. A U.L.-listed 1/2" (12.7 mm) conduit connector must be provided at the junction box. The recommended minimum copper wire size is 10-gauge. However, wire sizes and connections must conform to the requirements of the National Electrical Code and all local codes and ordinances. Venting system: Use metal vent only. Exception: Under a concrete slab, PVC may be used. Rigid metal vent is recommended. Do not use plastic or metal foil vent. This downdraft cooktop is rated at 60 feet (18.3 m) of straight vent or the equivalent. If vent length is 10 feet (3 m) or less, 6" (15.2 cm) diameter round vent may be used. If vent length is more than 10 feet (3 m), use 6" (15.2 cm) diameter round or 3-1/4" x 10" (8.3 x 25.4 cm) rectangular vent. Venting system must terminate to the outside. Cooktop location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. All openings in the wall or floor where cooktop is to be installed must be sealed. 2-15/16" (74.6 mm) burner box depth 15-5/8" (39.6 cm) blower housing depth 3-ft. (91.4 cm) long power supply cable factory installed. CABINET OPENING DIMENSIONS 30" (76.2 cm) min - 30" (76.2 cm) model 36" (91.4 cm) min - 36" (91.4 cm) model when higher than 18" (45.7 cm) See Note ** for minimum clearances Minimum distance to nearest combustible vertical surface extending 18" (45.7 cm) above cooktop Do Not seal cooktop to countertop. 21" (53.3 cm) opening depth 1" (25.4 mm) 29-1/2" (74.9 cm) - 30" (76.2 cm) model 35-1/2" (90.2 cm) - 36" (91.4 cm) model cutout width 24" (61 cm) minimum when bottom of wood or metal ** Note: cabinet is protected by not less than 1/4" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and bottom of unprotected wood or sheet metal. Exhaust Duct Cutout Locations 9-3/4" (24.8 cm) hole in rear or side of cabinet 29-1/2" (74.9 cm) - 30" (76.2 cm) model 35-1/2" (90.2 cm) - 36" (91.4 cm) model cutout width 17" (43.2 cm) 21" (53.3 cm) cutout depth Minimum base cabinet dimensions — 30" (76.2 cm) base cabinet width 24" (61 cm) base cabinet depth 25" (63.5 cm) countertop depth Countertop opening dimensions that are shown must be used. Given dimensions are minimum clearances and provide required 0" (0 cm) clearance. New installations — Follow minimum dimensions given. Replacement installation — Be sure that front edge of cooktop is at least 1-1/2" (38.1 mm) back from front edge of countertop. If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet. Side clearance — 6" (15.2 cm) minimum clearance between side of cooktop and side wall is recommended for maximum ventilation performance. Rear clearance — 3/4" (19.1 mm) clearance between rear edge of cooktop and rear wall is recommended. Motor/blower clearance — 2" (51 mm) minimum clearance between motor and cabinet is required for proper cooling. 6" (15.2 cm) clearance is recommended for servicing access. countertop 9-5/8" (24.4 cm) 30" (76.2 cm) cooktop 13-5/16" (33.8 cm) 36" (91.4 cm) cooktop 5" (12.7 cm) 2" (5.1 cm) minimum space to front edge of countertop Select required duct cutout (see Page 4 for exhaust duct cutout location). 18" (45.7 cm) Countertop must be supported within 3" (7.6 cm) of cutout. floor 11" (27.9 cm) 8" (20.3 cm) Install rear wall junction box in shaded area. Darker area is preferred. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. 8286553 08-11-05
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement