Marvel 30IM Ice Machine Installation, Operation & Maintenance Instructions
The Marvel 30IM Ice Machine is an efficient and reliable ice-making unit designed for residential and commercial use. It features a fractional freezing system that produces clear, high-quality ice cubes. This user-friendly unit includes a cleaning mode that helps maintain optimal performance and ice quality.
Advertisement
Advertisement
Marvel Ice Machine
Installation
Operation &
Maintenance
Instructions
Part of AGA Foodservice Group
1
S TA R T I N G O U T
Remove Packaging
Your ice machine has been packed for shipment with all parts that could be damaged by movement securely fastened. Before installing the ice machine, be sure all packing materials and tape have been removed.
Important
Save the carton packaging until your ice machine has been thoroughly inspected and found to be in good condition. If there is damage, the packaging will be needed as proof of damage sustained in transit.
Note to Customer
This ice machine was carefully packed and thoroughly inspected before leaving our plant.
Responsibility for its safe delivery was assumed by the carrier upon acceptance of the shipment. As directed on the side of the packaging carton, claims for loss or damage sustained in transit must be made on the carrier as follows:
Exterior Damage
Make a thorough damage notation on the delivery receipt and have the driver acknowledge by signing and dating. Send a written request asking for an inspection report from the carrier representative and the date the inspection was requested. Retain the inspection report and receipt for filing of a claim.
Concealed Damage
This must be reported to the carrier within fifteen days. Obtain an inspection report from the carrier.
Retain the inspection report for filing of the claim.
DO NOT RETURN DAMAGED MERCHANDISE
TO THE MANUFACTURER - FILE THE CLAIM
WITH THE CARRIER.
Select Location
The proper location will ensure peak performance of your ice machine. Choose a location away from heat and out of direct sunlight. Best performance will be maintained when installed within the following parameters:
Ideal Ambient Temperature Range
*
built-in freestanding
55-80°F
55-90°F
* Ice Machine will not perform correctly in ambient temperatures less than 55°F.
Cabinet Clearance
Ventilation is required for the bottom front section of the unit where the grille is located. Keep this area open and clear of any obstructions.
Adjacent cabinets and countertop can be built around the unit as long as no top trim or countertop is installed lower than the top of the hinge.
Make certain that the glides supplied with the ice machine are installed according to instructions.
Make certain your ice machine is level. Leveling adjustments can be made by raising or lowering the glides on the bottom of the unit.
Electrical Connection
Check the serial nameplate for the correct power supply. Use only the electrical power supply specified on the serial nameplate. Do not use an extension cord.
Grounding Method
This ice machine is equipped with a power supply cord with ground. It must be plugged into a mating grounding type receptacle in accordance with the
National Electrical Code and applicable local codes and ordinances.
Note: The plug shown is for 115VAC unit. The prongs on your model may vary from that shown if your unit is other than 115VAC.
THIS UNIT SHOULD NOT, UNDER ANY
CIRCUMSTANCES, BE UNGROUNDED.
I N S TA L L AT I O N
RPE style door
Full Wrap
Style Door
Overlay/Designer
Style Door
2
I N S TA L L AT I O N : D R A I N P L U M B I N G figure 1
Drain Plumbing
Your ice machine uses a gravity drain, (figure 1) that requires 5/8" I.D. tubing from the back of the ice machine to a plumbed connection to a sanitary sewer. Remove the access panel to plumb in drain connection. Gravity drain location for built-in units can be within the area shown in figure 3. An optional drain pump, (figure 2) can be purchased for your ice machine if a gravity drain is not accessible.
OBSERVE AND FOLLOW ALL LOCAL CODES
WHEN INSTALLING ICE MACHINE.
FAILURE TO USE ADEQUATE DRAINAGE
SYSTEM WILL RESULT IN SURROUNDING
WATER DAMAGE AND/OR POOR ICE
PRODUCTION.
figure 2
3 figure 3
Gravity Drain Location
* With optional filler kit
WAT E R S U P P LY
Water Supply
This ice machine must be connected to a potable, active cold water supply line delivering water pressure at a minimum of 20 psi and maximum of
120 psi.
• Water connection is made through a right angle garden hose fitting. See garden hose fitting for detailed instruction sheet.
• A water filter is recommended for this unit. A quality filter can remove particles as well as remove taste and odors from water. Do not use any thread sealers.
• Softened water is not recommended. This will produce mushy, cloudy ice cubes that will stick together.
• De-ionized water is not recommended. This water will not form solid ice cubes.
• A water specialist can recommend proper water treatment.
• After installation of water line, turn on water and check for any leaks. Additional tightening may be needed.
• Allow for extra water line for built-in installations for easy removal of unit and to help prevent the water line from kinking.
Operation
Your ice machine is unique in forming ice. It uses fractional freezing to form a slab of ice that is clear and has less mineral content than the water it is produced from. This is accomplished by running water over the cold evaporator plate which gradually freezes the water to produce the ice slab. Mineral deposits are left in the reservoir.
When the ice slab reaches the correct thickness determined by the temperature of the evaporator plate, the electronic control switches to the harvest cycle to harvest the ice. During the harvest cycle, the ice slab falls from the evaporator to the ice grid cutter. Here, the ice slab is cut into 3/4" squares by the grid cutter's heated wires. During the harvest cycle, the drain valve will remain open for 45 seconds to drain the reservoir of remaining deposits. After that, the water valve open will open for 2 minutes providing 2 quarts of water to the reservoir for the next ice production cycle.
The ice machine will keep producing ice until the ice machine's bin is full and will restart automatically when ice needs to be replenished in the bin.
4
5
C A R E O F T H E U N I T
Care of Unit
1. Avoid leaning on the cabinet door. You may bend the door hinge or tip the unit.
2. Exercise caution when sweeping, vacuuming, or mopping near the front of the unit. Damage to the grille and/or switch can occur.
3. Periodic cleaning of the inside of the ice machine components and inside of unit (see
Cleaning Your Ice Machine section).
4. Periodic checking and/or cleaning of the front grille and condenser coils as needed.
Normal Responsibilities of the Owner
• All freight charges
• Damage sustained in transit
• Mileage charge(s) for service calls
• Proper installation including installation of leveling legs.
• Leveling of unit.
• Alterations to original equipment
• Removal or installation of additional equipment
(i.e. drain pump).
• Cleaning and normal maintenance outlined in this manual.
• Drain and water supply plumbing to the ice machine.
Help Prevent Tragedies
Each year, children die because they climb inside a discarded refrigeration product, get trapped inside and suffocate. Take precautions to prevent such tragedies by removing the door, taping or chaining it shut before discarding.
C A R I N G F O R Y O U R I C E M A C H I N E
Cleaning Your Ice machine
Some impurities will remain and build-up in the ice machine and stick to the ice machine's parts over time. This build-up must be removed for proper ice production, ice quality, and ice machine life. Your ice machine is equipped with a cleaning mode that will help in cleaning out these impurities.
The impurities will regularly (at the very least, annually) need to be cleaned of this build-up, depending on use and water hardness. You can use an acid such as one specified for ice machine cleaning or you can use citric acid to remove the build-up. To clean the ice machine:
1.
Switch the selector switch to the "OFF" position.
2.
Remove the drain plug at the bottom of the reservoir to drain any remaining water and then reinstall.
3.
Add the recommend cleaner solution to the reservoir of the ice machine. Access to the reservoir can be obtained by removing the front panel screws and the front panel.
Determine to proper amount of cleaner from the ice machine cleaner manufacturer's mixture ratio based on 3 quarts of water (refer to manufacturer's directions).
4.
Replace the front cover panel and close the door.
5.
Switch the selector switch on the grille of the ice machine the clean position. Three quarts of water will automatically be added to the cleaning solution.
Read manufacturer's warnings on ice machine cleaner products. Personal injury can result.
7.
After the cleaning cycle has ended, remove the front panel again and check that the
8.
9.
build up has been removed. The evaporator plate should be clean, shiny, and smooth to the touch. If build up is still visible, repeat the cleaning cycle above. If build up is removed, continue below.
Remove the distributor tube, hose clamp, hose and its rubber ends.
Thoroughly clean the inside of the distributor tube and the spray holes. You can use the same cleaning solution as before and an old toothbrush to reach the inside of the distributor tube.
10.
Reinstall the rubber ends, hose, and hose clamp to the distributor and then reinstall the distributor tube to the evaporator with the spray holes pointed to the bottom of the evaporator plate. Reinstall the front cover panel with the two front panel screws.
11.
Clean the ice machine's interior, ice scoop, interior door panel and door gasket with mild soap and water. Using two tablespoons of baking soda in one quart of warm water while cleaning will help remove odors. Rinse with fresh water. Do not use any abrasive cleaning products.
Your ice machine is now clean and sanitized and may be put back into operation by switching the selector witch to the "ON" position.
6.
The total cleaning time will end in 49 minutes. The cleaning cycle will automatically rinse the evaporator plate and also drain the cleaning solution and rinse water.
6
7
T H I N G S T O R E M E M B E R
Things to Remember
• Allow your ice machine to run for 24-48 hours to accumulate ice in ice machine's bin.
• Unit will cycle often between ice production and ice harvest cycles.
• Your unit will automatically shut down when the ice bin is full.
• Unplug your ice machine before working on unit.
• Keep your ice machine clean for proper ice quality, production, and unit life.
• Room and water temperatures will greatly affect the output of ice in your unit (see table).
Ice will also melt away, especially at the start of an empty bin, but will slow down as ice accumulates.
PRODUCTION RATE
(LB/DAY)*
WATER TEMPERATURE °F
70
80
90
50
34
30
23
70
32
27
20
APPROXIMATE TIME TO FILL
BIN (HOURS)*
WATER TEMPERATURE °F
70
80
90
50
31
41
60
70
34
58
82
*NOTE: DUE TO VARIABLES IN INSTALLATION AND USE, INDIVIDUAL RESULTS MAY VARY.
D O O R A LT E R AT I O N S
Optional Door Handle Installation
(for units without door handle attached)
The door handle for certain doors may be packed inside your ice machine can be mounted on the top or side of your refrigerator door. Locate the handle where it is convenient for you. You will need a 1/4" hex head driver to install the handle.
Place the handle on the outside surface of the door. Push gently inward toward the door until the handle snaps in place. Use the two screws supplied to secure the handle to the door frame by tightening the screws into the holes on the backside of the handle. Tighten the screws until the tips of the screws touch the bottom of the backside of the door frame. Your installation is complete.
Reversing the Door
You may want to change the side on which the door opens and closes. This can be changed by the following steps.
1. Remove the door by removing the top hinge pin and angling the door off of the bottom hinge pin.
2. Gently pry out the hole plugs on the side which the hinges will be mounted. A thin knife will usually allow the hole plug to be removed just enough to pull the rest of the way out by hand. Do not destroy these plugs because they will be used on the other side of the unit.
3. Remove the hinges from the unit.
4. Remove the hinge pin from the bottom hinge that was removed. Install this pin on the other hinge that was also removed.
5. Install the hinges on the desired side of the unit.
6. Install the door by inserting the bottom door bushing with the bottom hinge pin and angling door in until top door bushing and hinge line up. Install the upper hinge pin.
7. Install the hole plugs from step 2 in holes.
8
9
O B TA I N I N G S E R V I C E
Before Calling for Service
Before calling for service, check the following items:
• Make sure unit is plugged into outlet.
• Check the outlet for power. Test outlet with lamp to make certain outlet has power.
• Make sure ice machine's switch is in the "ON" position.
• Make sure that there is cold water supplied to the ice machine.
• Make sure drain plug on bottom of reservoir is inserted.
• Make certain unit is level from front to back and side to side.
• Make certain that the drain line to the ice machine is unrestricted or kinked.
• Use troubleshooting guide, pages 11-14 for other diagnosis.
If you are not able to correct the problem, contact your dealer or the manufacturer. Be sure to have the model number and the serial number handy before you call. The model and the serial number are located on the lower front part of the ice machine's cabinet.
How to Obtain Service
Your ice machine requires little service because the best and most up-to-date materials, equipment and quality control methods are employed throughout the manufacturing process.
If trouble occurs during normal operation, read
"Things to remember" section first and, if necessary, check the troubleshooting guide. If service becomes necessary:
1. Contact the dealer where your appliance was purchased or the manufacturer for the name of the nearest authorized service representative. The service representative will have full authority to make any repairs deemed necessary.
2. If you are in an area where there is no service representative, write or call the manufacturer directly. We will make recommendations as to the proper procedure for correction. Service work and replacement parts, if required, will be provided as covered by your limited warranty.
3. In all correspondence regarding service, be sure to give the model number, serial number and proof of purchase.
4. Try to have information or description of the nature of the problem, how long the unit has been running, the room temperature, water temperatures, and any additional information that may be helpful in quickly solving the problem.
SEND IN YOUR WARRANTY RECORD
CARD IMMEDIATELY AFTER TAKING
DELIVERY OF YOUR ICE MACHINE.
Every new ice machine that leaves the factory contains this Owner's Guide. Keep this Owner's
Guide in a safe place for convenient reference.
For Your Records
Date of Purchase
Dealer’s Name
Dealer’s Address
Dealer’s city
Appliance Serial Number
Model Number
Date Warranty Card Mailed (within 10 days of purchase)
Dealer’s State Zip
Entire Product
Limited One Year Parts and Labor Warranty
Marvel warrants that it will supply all necessary parts and labor to repair or replace in the end user's home or office, any component which proves to be defective in material or workmanship, subject to the condition and exclusions stated below, for a period of one year from the date of purchase by the end user.
Additional Second Through Fifth Year
Limited Parts Only Warranty
During the four years following expiration of the one year limited warranty, Marvel will supply replacement parts for the hermetically sealed refrigeration system which consists of the compressor, condenser, drier, accumulator, by-pass valve, connecting tubing and the evaporator that are proven to be defective due to workmanship or materials subject to the conditions and exclusions below.
The above warranties do not cover:
• Shipping costs of replacement parts or returned defective parts.
• Customer education or instructions on how to use the appliance.
• Any content loss due to product failure.
• Removal or installation.
Nor do the above warranties cover failure of this product or its components due to:
1. Transportation or subsequent damages.
2. Use commercially or use other than normal household or small office.
3. Improper installation, misuse, abuse, accident or alteration, use on wiring not conforming to electrical codes, low or high voltages, failure to provide necessary maintenance, or other unreasonable use.
Parts or Service
Not Supplied or Designated by Marvel
The above warranties also do not apply if:
The original bill of sale, deliver date or serial number cannot be verified.
Defective parts are not returned for inspection if so requested by Marvel.
The refrigeration equipment is not in the possession of the original end use purchaser.
The warranties set forth herein are the only warranties extended by Marvel Industries. Any implied warranties, including the implied warranty of merchantability, are limited to the duration of these express warranties. In no event shall Marvel
Industries be liable for any consequential or incidental damages or expenses resulting from breach of these or any other warranties, whether express or implied.
Some states do not allow the exclusion or limitation of consequential damages or a limitation on how long an implied warranty lasts, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights and you may have other rights that may vary from state to state.
No person, firm, or corporation is authorized to make any other warranty or assume any other obligation for Marvel Industries. These warranties apply only to products used in any of the fifty states of the United States and the District of
Columbia.
To obtain performance of this warranty, report any defects to:
Marvel Industries
P.O. Box 997
Richmond, Indiana 47375-0997
Phone: 765-962-2521
WA R R A N T Y
10
11
T R O U B L E S H O O T I N G O N E
PROBLEM POSSIBLE CAUSE CORRECTION
Unit does not operate.
The unit is unplugged.
Breaker is tripped or fuse is blown.
Ice machine selector switch is in the "OFF" position.
Plug in the unit.
Reset breaker or replace fuse. Check to make sure there is not a short in the electrical circuit.
Set the rocker switch on the grille of the ice machine to the
"ON" position.
Unit operates but does not produce any ice.
The unit has just been started and it has been less than 6 hours.
Typical ice production cycle can take up to
1.5 hours. Initial startup cycles can be longer.
The selector switch is in the "OFF" or
"CLEAN" position.
No water in the reservoir.
Distributor tube is restricted.
Build up of deposits on evaporator plate.
Condenser fan air flow is restricted.
Room and/or water temperature is too warm.
Leaking drain valve.
Inadequate drain system.
Grid cutter is unplugged.
Ice produced when the unit is initially started will melt off in the bin. Ice will accumulate in the bin. In 6 hours there can be a few cubes in the bin. This is normal operation.
Check the unit in 24 hours for ice accumulation in the bin.
Set the rocker switch on the grille of the ice machine to the
"ON" position.
Make sure that the reservoir drain plug is installed. Check the water line to the unit to make sure it is on and that there are no restrictions or kinks in the line. Check all filters to make sure they are not restricted or plugged.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation.
Make certain the grille in the front of the unit is free and open for proper air circulation. Check and clean the condenser coil by removing the grille in the front of the unit.
Clean the condenser with a vacuum and brush attachment.
Move the unit to an area where ambient temperature is below 90 deg. F. The unit should not be placed next to a heat source such as an oven. Check for cold water connection.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit. This will also dissolve and flush out foreign material in the drain valve causing it to leak.
Restriction in drain lines will cause ice in the bin to melt. If using a gravity drain, make certain there are no kinks or restrictions in the drain lines. If using a drain pump, check the inlet screen, discharge line, and vent line for any build or restrictions.
Plug in the grid cutter so that ice slabs can be cut into cube.
T R O U B L E S H O O T I N G T W O
PROBLEM
Ice cubes are too small (less than
1/2 inch thick).
Hollow ice slab.
POSSIBLE CAUSE
Low ice consumption.
Not enough water in reservoir.
Distributor tube is restricted.
Build up of deposits on evaporator plate.
Inadequate drain system.
Leaking drain valve.
Ice cubes are too big (greater than
3/4 inch thick).
Room temperature is too warm.
Ice slab not releasing.
Condenser fan air flow is restricted.
Room temperature is too warm.
Distributor tube is restricted.
Build up of deposits on evaporator plate.
Low water level in reservoir.
CORRECTION
Ice is slowly melting in the ice bin and will affect the size of the ice cube. This is normal operation. When the ice bin needs to be replenished, cubes will return to regular size.
Make sure that the reservoir drain plug is installed properly.
Check the water line to the unit to make sure there are no restrictions or kinks in the line. Check all filters to make sure they are not restricted or plugged.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation and cube size.
Restriction in drain lines will cause ice in the bin to melt to a thinner cube. If using a gravity drain, make certain there are no kinks or restrictions in the drain lines. If using a drain pump, check the inlet screen, discharge line, and vent line for any build or restrictions.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit. This will also dissolve and flush out foreign material in the drain valve causing it to leak.
Move to an area where temperature is below 90 deg. F.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation and cube size.
Make certain the grille in the front of the unit is free and open for proper air circulation. Check and clean the condenser coil by removing the grille in the front of the unit.
Clean the condenser with a vacuum and brush attachment.
Move to an area where temperature is below 90 deg. F.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation and cube size.
Make sure that the reservoir drain plug is installed properly.
Check the water line to the unit to make sure there are no restrictions or kinks in the line. Check all filters to make sure they are not restricted or plugged.
12
13
T R O U B L E S H O O T I N G T H R E E
PROBLEM POSSIBLE CAUSE CORRECTION
Ice is not clear.
Low ice production. Unit is running, has run over a 48 hour period, and there is little ice in bin.
Unit continues to run and produce ice.
Grid-cutter is not cutting the ice slab.
Low water level in reservoir.
Softened water supply.
Room temperature is too cold.
Low water level in reservoir.
Distributor tube is restricted.
Build up of deposits on evaporator plate.
Inadequate drain system.
Condenser fan air flow is restricted.
Ice bin is not full.
Ice bin is full.
Room temperature is too warm.
ice machine is not level.
Make sure that the reservoir drain plug is installed properly.
Check the water line to the unit to make sure there are no restrictions or kinks in the line. Check all filters to make sure they are not restricted or plugged.
Make certain that water line is not connected to the water softener.
Move the unit to an area where room temperature is above
55 deg. F.
Make sure that the reservoir drain plug is installed properly.
Check the water line to the unit to make sure there are no restrictions or kinks in the line. Check all filters to make sure they are not restricted or plugged.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation.
See "CLEANING YOUR ICE MACHINE" section for cleaning the unit for proper operation.
Restriction in drain lines will cause ice in the bin to melt. If using a gravity drain, make certain there are no kinks or restrictions in the drain lines. If using a drain pump, check the inlet screen, discharge line, and vent line for any build or restrictions.
Make certain the grille in the front of the unit is free and open for proper air circulation. Check and clean the condenser coil by removing the grille in the front of the unit.
Clean the condenser with a vacuum and brush attachment.
The unit will automatically shut down when ice reaches the sensing tube.
The unit will automatically shut down when ice reaches the sensing tube and has completed the harvest of the ice slab.
Move the unit to an area where room temperature is below
90 deg. F.
Use a level to check the unit for level from side to side and front to rear.
The selector switch is not in the "ON" position
The grid cutter is not plugged into the receptacle.
Time to cut through the slab
Set the rocker switch on the grille of the ice machine to the
"ON" position.
Remove the escutcheon panel and plug the grid-cutter into the receptacle on the side of the line.
It can take up to 35 minutes to cut through a harvested ice slab. This is normal operation.
T R O U B L E S H O O T I N G F O U R
PROBLEM POSSIBLE CAUSE CORRECTION
Ice cubes are sticking together.
Ice level is too high.
Ice consumption is low.
Room temperature is too warm.
The ice machine is not level.
Room temperature is too warm.
Ice deflector is not in place or secured properly.
Bin level sensing tube needs adjusted.
Use the ice in the bin frequently. Ice will stick together if left in insulated bin over long periods of time.
Move the unit to an area where temperature is below 90 deg. F.
Use a level to check the unit for level from side to side and front to rear.
Move the unit to an area where temperature is below 90 deg. F.
Check to see that the ice deflector is in place and secured below the grid-cutter.
You can adjust the bin level sensing tube by simply pressing directly down on the tube 5 inches from the front of the tube to get a desired bin level.
Ice level is too low.
Water keeps backing up into the ice bin (gravity drain).
The ice machine is not level.
Room temperature is too cold.
The selector switch is not in the "ON" position
Use a level to check the unit for level from side to side and front to rear.
Move the unit to an area where temperature is above 55 deg. F.
Set the rocker switch on the grille of the ice machine to the
"ON" position.
Inadequate drain system.
Foreign material in ice bin drain.
Restriction or improperly installed drain lines will cause water to back up into the ice bin. Make certain there are no kinks or restrictions in the drain lines. If necessary, consult a qualified plumber.
Foreign material is restricting or blocking the ice bin drain located at the right rear corner of the ice bin. The drain will need to be cleared.
Water keeps backing up into the ice bin (drain pump).
Drain pump tubing kinked or restricted.
Check inlet, discharge, and vent line tubing for any kinks or restrictions and repair as necessary.
Clean the inlet screen to the drain pump. Inlet screen to the drain pump is restricted or blocked.
Drain pump and/or the ice machine are not level.
Check and level if necessary the drain pump as well as the ice machine.
The drain pump cycles on and off erratically.
Vent line to the drain pump is restricted or kinked.
Discharge line is restricted or kinked.
The drain pump is not level.
Check the vent line for any restrictions or kinks and repair as necessary.
Check the discharge line and connection to the desired drain for any restrictions or kinks and repair as necessary.
The drain pump must be level. Check for level on the top of the drain pump case and adjust the tubing or use shims to level.
14
15
S E R V I C E PA R T S D I A G R A M O N E
Illus. No.
5A
5B
6
7A
3
4
1
2
7B
8
9
Description
Cabinet Assembly
Hole Plug
Screw
Escutcheon
Plastic Grille (White)
Plastic Grille (Black)
On-Off-Clean Switch
Screw (White Plastic Grille)
Screw (Black Plastic Grille)
Stainless tin panel (Optional)
Screw (Optional)
Qty. Req.
1
1
1
1
2
1
1
6
1
1
2
S E R V I C E PA R T S L I S T O N E
Part No.
Various
41001929
41004079
41005700
41006376
41006274
41005824
41005486
08205072
42284093
08204920
Service Assembly
Various
Various
42242989
42242989
42243390
42243391
42242992
42243390
42243391
42244709
42244709
16
17
S E R V I C E PA R T S D I A G R A M T W O
Illus. No.
20
21
22
23
16
17
18
19
24
25
26
27
12
13
14
15
8
9
10
11
6
7
4
5
1
2
3
Description Qty. Req.
Distributor Tube End
Distributor Tube
Tubing
Evaporator Assembly
Screw
Clamp
Hose Clamp
Washer
Screw
Circulation Pump
Reservoir
Spacer
Screw
Clamp
Sleeve w/ thermistor
Screw
Screw
Drain Plug
Grid-Cutter Assembly
Deflector
Screw
1
4
Wellnut 20
Screw 1
1
1
2
4
Thermistor
Retainer Clip
Screw
Ice Scoop
2
1
1
1
1
1
2
2
1
1
2
2
1
1
1
4
2
1
1
S E R V I C E PA R T S L I S T T W O
Part No.
41005705
41005515
41005042
42052559
08204920
41006002
41006126
08205068
08204920
41005537
41005345
41004366
41005773
1150003A
42154607
08204920
08204920
41005859
42412615
41006040
08204920
41005503
41004079
41006205
41006042
08204920
41005536
Service Assembly
42242977
42242976
42242976
42242978
42242978
42242978
42242976
42242981
42242980
42242980
42242981
42242981
42242981
42242986
42242986
42242986
42242984
42242982
42242984
42242985
42242985
42242987
42243392
42243392
42242975
42242975
42242993
18
19
S E R V I C E PA R T S D I A G R A M T H R E E
Illus. No.
28
29
30
31
25
26
27
27
21
22
23
24
17
18
19
20
13
14
15
16
9
10
11
12
7
8
5
6
3
4
1
2
43
44
45
46
40
40
41
42
46
47
36
37
38
39
32
33
34
35
Description Qty. Req.
Condenser
Pop Rivet, Steel
Coil Retainer
Solenoid Coil
Hot Gas Valve
Drier Assembly
Speed Nut
Fan Shroud
Fan Blade
Silencer, Spacer
Locknut
Fan Motor Assembly
Carriage Bolt
Carriage Bolt
Carriage Bolt
Sleeve, Compressor
Grommet, Compressor
Locknut
Lock Washer
Ground Wire, Compressor
Lock Washer
Screw
Washer
Locknut
Compressor Assembly
Compressor PTC Starter
Back Panel
Back Panel-Stainless Steel
Power Cord Clamp
Locknut
Carriage Bolt
Baseplate
Water Valve Assembly
Drain Valve
Screw
Screw
Tee Fitting
Hose Clamp
Power Cord
Bracket
Screw
Screw-Stainless Steel
Electronic control
Transformer
Screw
Terminal Block
U-Clip
Access panel assembly
Access panel assembly-Stainless Steel 1
Compressor Overload 1
24
24
1
1
1
1
6
1
1
1
1
4
2
2
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
4
1
1
2
5
2
5
1
1
1
1
1
1
1
1
1
1
4
Part No.
41008198
41006874
41005417
41001401
08205116
08205200
08204877
08205051
41008182
41008200
41009202
41009203
41006046
41006874
1130006A
41006276
41003609
41003962
41003662
41003601
41003914
42102389
41000153
41006282
41003616
M000101A
41006874
42183571
1130006A
08205114
1130006A
41008199
42262644
41005530
08204928
08204928
41005702
41006769
41006733
41005868
08204928
41005076
41006035
41005681
41005086
41005078
41005945
41005943
41008533
41008201
S E R V I C E PA R T S L I S T T H R E E
Service Assembly
42243194
42242900
42242900
42242900
42242900
42242900
42243194
42243194
42243194
42244702
42242962
42245300
42242963
42242963
42242963
42242964
42243035
42243035
42242020
42242020
42242020
42242961
42244701
42244704
42244701
42244701
42244701
42244701
42244701
42243194
42242900
42243194
42242965
42242966
42242965
42242966
42242967
42242967
42242963
42242968
42242962
42245300
42243384
42242973
42242971
42242971
42243015
42243016
42245301
42244703
20
21
S E R V I C E PA R T S D I A G R A M F O U R
Illus. No.
9
10
11
12
13
14
7
8
5
6
3
4
1
2
S E R V I C E PA R T S L I S T F O U R
Description
Hinge Pin
Screw
Hinge
Handle
Screw
Door Gasket
Hinge
RPE Cap Assembly
Screw
Door, Complete Assembly, 30IM
Hinge Bushing
Door Nameplate
Hinge Adapter Screw
Hinge Adapter
Qty. Req.
4
1
2
1
4
2
1
1
2
1
1
1
2
6
Part No.
41004106
Various
Various
Optional
Optional
41006285
Various
Optional
Optional
Various
41000255
Various
Optional
Optional
Service Assembly
2240013A
Various
Various
Optional
Optional
42243388
Various
Optional
Optional
Various
2240013A
Various
Optional
Optional
22
41006412 Rev. G
W W W . M A R V E L I N D U S T R I E S . C O M
Phone: (765) 962-2521 Fax: (765) 962-2493
MARVEL
I N D U S T R I E S
Part of AGA Foodservice Group
233 Industrial Parkway
P.O. Box 997
Richmond, IN 47375-0997

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Fractional freezing system
- Clear, high-quality ice cubes
- Automatic ice production and harvest
- Cleaning mode
- Adjustable ice cube size
- Easy-to-use controls