York | Floor Ceiling R-410A 50Hz | Product Line Card

Systems, services and solutions that make buildings work and people achieve.
HVAC SYSTEM CONTROL PRODUCTS
BUILDING MANAGEMENT SYSTEMS
METASYS®
VARIABLE-SPEED DRIVES Open, enclosed and bypass
drives, 1-250 HP, engineered solutions available
APPLICATION & DATA SERVER
Support of IT standards and technologies,
web-based user interface, long-term data storage.
NETWORK AUTOMATION ENGINE
Scalable family of engines from the smallest system
to an enterprise network.
FIELD EQUIPMENT /
ADVANCED APPLICATION CONTROLLERS
Complete family of field controllers and accessories
WIRELESS COMPONENTS
Wireless field buses and room environment sensing
systems designed with the latest wireless technology.
TERMINAL EQUIPMENT CONTROLLERS
Complete local control of unitary equipment, plus
supervisory communication. Available in BACnet®,
LON® and N2 configurations.
AIRFLOW MEASURING SYSTEM Differential pressure
or thermal dispersion
MODULAR ELECTRONIC CONTROLS
C450C Temperature, Pressure and Humidity Controls
C450Y Power Module, C450S Expansion Modules
CUSTOM & STANDARD PANELS Pre-wired and
pre-assembled, standard and custom control panels
LUBE OIL CONTROLS
P28/P128 Lube Oil Controls, P45/P145 Lube Oil
Controls, P545 Electronic Lube Oil Controls
YAH 880-8823 CFM • Elegant design, Stability, High heat
efficiency, Easy installation and maintenance.
LASER 800–12000 CFM • Standard and District
Cooling coils, IP 55 motor, Ducted Belt Driven.
CPO 30 POWERED BY OPTIMUM ENERGY™
Engineered solution uses relational control algorithms
to achieve up to 60% energy savings (including plant
upgrades) and real-time dashboards to help assure
persistent performance.
JST 800–12000 CFM • Standard and District Cooling
coils, IP 55 motor, Ducted Belt Driven.
VAV TERMINAL BOXES • 75-8,000 CFM
Single or dual-duct, series or parallel fan-powered,
flexible factory-packaged controls, wireless-ready option
UNDERFLOOR AIR DISTRIBUTION SYSTEMS
FLEXSYS™ SYSTEM
VARIABLE AIR VOLUME • 100 to 300 CFM
- Unique time-modulation control, variety of sizes,
shapes and colors
MANUAL DIFFUSERS • 80 to 300 CFM
- Variety of sizes, shapes and colors, user control,
directional and omni-directional
DOOR & SUPERVISORY CONTROLLERS
The advanced, intelligent, network controllers capable
of handling high volume, high-speed traffic.
FAN TERMINAL UNITS • up to 1800 CFM
- Programmable circuit board design, electric or hot water
CAMERAS & DVR’S • The solution provides a fully
featured digital audio/video recording and management
system for 8, 16, or 32 cameras.
INTEGRATED VMS SYSTEMS • Based on true clientserver architecture, offer exceptional levels of video
and audio recording.
FAN SPEED CONTROLS
P70/P170 Pressure Controls, P266 Electronic Fan Speed
Controls, VFD66 Condenser Fan Speed Controls
YDFC 800-2200 CFM • Extremely low unit cost ,best
used on large projects where full containers can be
shipped CPO 10 POWERED BY METASYS
Intelligent algorithms inherent in Metasys leverage
proven best practices and specific equipment
efficiency characteristics to save up to 15% energy
versus standard automation.
SECURITY MANAGEMENT SYSTEM
Interactive, real-time security management
Fully-expandable base P2000 system that supports 5
concurrent user connections via thin or thick clients.
SENSORS & THERMOSTATS Temperature, humidity
and CO2 sensors including analog, hardwire network
and wireless applications
YGFC 200-1400 CFM • CE certified, extremely low unit
cost best used on large projects where full containers can
be shipped CENTRAL PLANT OPTIMIZATION™ (CPO)
SECURITY MANAGEMENT SYSTEM PRODUCTS
PRESSURE CONTROLS
P735 Low and High Pressure Controls, P736 Dual Pressure
Controls, P100 Pressure Switch.
250-8000 CFM • Exposed and concealed, horizontal &
vertical, variable cabinet sizing, direct-drive and beltdrive, flexible factory-packaged controls, wireless-ready
option
Adapts legacy and proprietary systems to current
open systems architecture.
LINEAR GRILLE TROUGHS • up to 900 CFM
- Heating/cooling - electric or hot water,
time-modulation, VAV control option
AIR HANDLING UNITS & COILS
SOLUTION • Air handling units with High performance,
Modular construction. Manufactured in USA
FIRE SAFETY SYSTEMS
TEMPERATURE CONTROLS
A19 Temperature Controls, A419 Electronic Temperature
Controls, ER Defrost Controls.
VALVES, ACTUATORS & DAMPERS Global product
family, broad selection, easy installation
TERMINAL UNITS - FAN COIL UNITS
INTEGRATION COMPONENTS
COMMERCIAL REFRIGERATION SYSTEM CONTROLS
DIGITAL VOICE COMMAND SYSTEMS
(EVACUATION PANELS) Multi-channel digital audio
evacuation, paging and firefighter’s telephone system.
YMA CUSTOM MADE AIR HANDLING UNITS.
Flexible construction, premium product. Manufactured in
KSA / Turkey / Italy
INTELLIGENT FIRE ALARM CONTROL PANELS (FACP)
Supports from up to 318, 636, and 3180 intelligent
addressable devices combined with many other
powerful features.
YMS AIR HANDLING UNITS with modular construction,
standard product. Manufactured in UAE / KSA
WATER REGULATING VALVES • V43/V46 Water
Regulating Valves, V146 High Pressure Regulating Valves
• V246/V248 Water Regulating Valves for High Pressure
Refrigerants
FLOW AND FLOAT CONTROLS • F61 Flow Switches,
F63 Float Switches, F59 Sump Pump Switches
INDUSTRIAL REFRIGERATION
CHILLERS WITH SCREW COMPRESSOR – PAC
• Cooling Capacity Range – 120 - 8000 kW, Skid
mounted - factory tested
FIELD DEVICES (PERIPHERALS) Offers a wide range
of field devices: Pull Station (Call-Point), Multi-function
Detector, Speakers, horns/mini horns & strobes.
Building Information Modeling Files Available
Heat Pump Option
Heat Recovery Option
JMS MODULAR AIR HANDLING UNITS with self
supported panels, clean concept. Manufactured in UAE
JST SINGLE / DOUBLE SKIN BELT DRIVE • Air handling
units for Indoor applications. Manufactured in UAE / KSA
INTEGRATED CONTROLS Johnson controls offers a
complete solution with optimized sequence of operation
and energy performance.
Portions of offering have seismic certification
SUNLINE 2000 SERIES
36, 48, 60 & 76 MBH Cool only R407C Refrigerant 50Hz
CASCADE REFRIGERATION PACKAGE - CAFP • Cooling
Capacity Range – 80-800 kW, Low Operating Cost And
Compact Design
SCREW COMPRESSOR UNIT • Cooling Capacity Range
– 121-5700 kW, Highest COP value
RECIPROCATING COMPRESSOR UNIT • Cooling Capacity
Range – 50-1400 kW, Low Power Consumption During
Part Load
MULTISTAGE CENTRIFUGAL COMPRESSOR UNIT •
Cooling Capacity – Up To 11 500 kW, Designed For
Heavy Industrial Use
OTHER REFRIGERATION PRODUCTS
- AcuAir Hygienic Air Handler
- Plate and Frame Heat Exchangers
- Refrigerants Vessels
PIONEER VRF SERIES
87 to 420 MBH Cool Only &
Heat Pump R22 & R410A 50Hz
GRANDE VRF SERIES
77 to 617 MBH Heat Pump R410A 50Hz
MINI VRF SERIES
30 to 60 MBH Heat Pump R410A 50H
AMAZON VRF SERIES
80 to 390 MBH Heat Pump R410A 50Hz & 60Hz
ATW / ESWA / LSW CLOSE CIRCUIT COOLERS –
Induced / forced draft counter flow. Capacity range 30
– 2,650 tons.
AIR-COOLED CHILLERS
YORK YCAL • 15 – 65 tons • Scroll compressor,
Brazed plate evaporator, BAS communications,
service isolation valves, Refrigerant HFC-410A
SUNLINE 2000 SERIES
180, 240 & 300 MBH Cool only R407C Refrigerant 50Hz
YORK YLAA • 70 – 180 tons • Scroll compressor,
Shell-and-tube DX evaporator, Micro channel coils,
BAS communications, Refrigerant HFC-410A
DMS MICRO SERIES 36, 48, 60, 76 & 90 MBH
Cool only R22 Refrigerant 50Hz & 60Hz
YORK YLPA HEAT PUMP • 97– 150 tons • Scroll
compressor, Shell-and-tube DX evaporator,
Refrigerant HFC-410A
DMS MINI SERIES 90, 100, 120 & 150 MBH
Cool only R22 & R407C Refrigerant 50Hz & 60Hz
DMS STANDARD SERIES 190, 240, 260 & 320 (340 60Hz)
MBH Cool only R22 & R407C Refrigerant 50Hz & 60Hz
YORK YVAA • 150– 275 tons • Variable-speed
screw compressor, Hybrid falling film evaporator,
Refrigerant HFC-134a
DMS MAJOR SERIES 360,420, 480 & 600 MBH
Cooling only R22 & R407C Refrigerant 50Hz & 60Hz
DUCTLESS SPLIT UNITS
HIGH WALL SPLIT UNITS
ROCKIES SERIES 18 TO 30 MBH
Cool only & Heat pump R22 Refrigerant 50Hz & 60Hz
TAURUS SERIES 9 TO 42 MBH Cool only &
Heat pump R22, R407C Refrigerant 50Hz & 60Hz
HIGH TEMPERATURE HEATPUMP PACKAGE •
Heating Capacity Range – Up To 1600 kW, Outgoing
Temperature – Up To 90°C
LSTE COOLING TOWER - Forced Draft Counter flow.
CTI certified. Capacity range 150 -1,800 tons.
PREDATOR SERIES
90,120 & 150 MBH Cool only R407C Refrigerant 50Hz
COMPACT CHILLER - CHILLPAC • Cooling Capacity
Range – 200 - 1400 kW, Very Compact (Door Width
1000 mm)
STANDARD HEATPUMP PACKAGE - HEATPAC •
Heating Capacity Range – 240 - 1150 kW, Outgoing
Temperature – Up To 70°C
AT COOLING TOWER - Induced Draft Counter flow.
CTI certified. Capacity range 30 – 5,750 tons.
AIR COOLED PACKAGE UNITS
ULTRA SERIES 12 TO 36 MBH
Cool only & Heat pump R22 Refrigerant 50Hz
AIR COOLED CHILLER - SABLIGHT • Cooling Capacity
Range – 120 - 338 kW, “Green” Refrigerant – R290
COOLING TOWERS & CLOSED CIRCUIT COOLERS
YMPCS - Pre-designed factory assembled
self-contained system shipped in modules and
assembled at site. Range – 1,000 - 20,000 tons.
CHILLERS WITH PISTON COMPRESSOR - PAC •
Cooling Capacity Range – 50 - 1400 kW, Skid mounted
- factory tested
VARIABLE REFRIGERANT FLOW SYSTEMS
INTELLIGENT FIRE INTEGRATOR
A single point of control workstation for your fire and
life safety systems.
MODULAR PACKAGED CHILLING SOLUTIONS
SIERRA SERIES 12 to 36 MBH Cool only &
Heat pump R22 & R410A Refrigerant 50Hz & 60Hz
COMMERCIAL FREE STANDING SPLIT UNITS
Taurus Series 72 to 100 MBH Cool only &
Heat pump R22 Refrigerant 50Hz & 60Hz
RESIDENTIAL FREE STANDING SPLIT UNITS
TAURUS SERIES 24 to 70 MBH Cool only &
Heat pump R22 & R407C Refrigerant 50Hz & 60Hz
CASSETTE SPLIT UNITS
TAURUS SERIES 18 to 60 MBH Cool only &
Heat pump R22 & R407C Refrigerant. 50Hz & 60Hz
FLOOR/CEILING SPLIT UNITS
TAURUS SERIES 18 to 60 MBH Cool only &
Heat pump R22 & R407C Refrigerant 50Hz & 60Hz
DUCTED SPLIT UNITS
RESIDENTIAL DUCTED SPLIT UNITS
YORK YCIV/YCAV • 150– 440 tons • Variablespeed screw compressor, shell-and-tube
evaporator, Refrigerant HFC-134a
WATER-COOLED CHILLERS
ELECTRIC
YORK® YCWL • 50 – 200 tons
• Scroll compressor, Refrigerant HFC-410A
YORK YS • 100 – 435 tons
• heat-pump capability, customizable,
OptiView™ control panel, Refrigerant HFC-134a
YORK YR • 100 – 435 tons
• Unit-mounted solid-state starter,
OptiView™ control panel, Refrigerant HFC-134a
YORK YK • 250 – 3,000 tons
• Variable-speed centrifugal compressor,
OptiView™ control panel, Refrigerant HFC-134a
YORK YK-EP • 2,500 – 3,500 tons • Centrifugal
compressors with economizer, variable-speed drive,
OptiView™ control panel, Refrigerant HFC-134a
YORK YD • 1,500 – 6,000 tons • Dual Centrifugal
compressors, smallest footprint per cooling ton,
OptiView™ control panel, Refrigerant HFC-134a
YORK CYK • 300 – 2,500 tons • High-head capability,
thermal (ice) storage, compound centrifugal
compressors with economizer, Refrigerant HFC-134a
YORK OM • 3,000 – 5,500 tons • Custom-designed,
centrifugal compressor, electric-motor, steamturbine or gas-engine drive, Refrigerant HFC-134a
THERMALLY DRIVEN
TAURUS SERIES • 12 to 80 MBH Cool only,
Heat Pump R22 & R407C Refrigerant 50Hz & 60Hz
YORK YST • 700 – 2,800 tons - Centrifugal compressor,
steam-turbine driven, HFC-134a refrigerant
OLYMPIAN III SERIES • 18 to 70 MBH
Cool only R22 Refrigerant 50Hz & 60Hz
YORK YWA • 100–2000 tons • Highest industry COP,
split absorber design, water tube generator, touch
screen PLC, crystallization prevention logic, automatic
purge system
COMMERCIAL DUCTED SPLIT UNITS
TAURUS SERIES • 72 to 300 MBH Cool only &
Heat Pump R22 & R407C Refrigerant 50Hz & 60Hz
COMMERCIAL CONDENSING UNITS
DCS SERIES • 360,420, 480 & 600 MBH Cooling only
R22 & R407C Refrigerant 50Hz & 60Hz
WINDOW ROOM AIR CONDITIONERS
MILLENNIUM SERIES • 9 to 24 MBH
Cool only & Heat Pump R22 Refrigerant 50Hz
SIERRA SERIES • 9 to 24 MBH
Cool & Heat Pump R22 Refrigerant 50Hz
TAURUS SERIES • 9 to 28 MBH
Cool only & Heat Pump R22 & R407C Refrigerant 50Hz
YORK YPC • 200 – 700 tons • Absorption chiller, twostage, gas, oil, or high-pressure-steam driven, water
refrigerant
CONDENSING UNITS & CONDENSERS
YC/YD & NC/ND SPLIT SYSTEM • 7.5 – 50 tons
Scroll compressors, HFC-410A refrigerant
YORK YCUL • 40 – 80 tons - Condensing unit,
Scroll compressors, HFC-410A refrigerant
YORK YLUA • 80 – 160 tons - Condensing unit,
Scroll compressors, HFC-410A refrigerant
YORK VDC • 175 – 2,280 MBH - Air-cooled condenser,
multiple refrigerants
YORK VDCF • 65 – 2,890 MBH - Fluid cooler,
water or glycol
ENTHALPY
HUMIDITY RATIO
‡h
‡W
3
0.76
-5
-5
0
5
0
5
10
10
15
0.82
-2
0
-10
-1
0
1.2
-15
-1
5
-10
-5
0
5
LATIVE
25
ITY
HUMID
ER P
10
20
DRY BULB TEMPERATURE - °C
20
10% RE
20%
30%
%
40
%
50
15
20
30
IR
-20
-20
-15
0
10
10
15
20
0.84
-25
-2
0
-1
0
Δt = temperature difference ( C)
o
20
30
40
50
-
h = heat flow rate (kW or kJ/s)
q = water flow rate (m /s)
where
q = h / (4200 Δt)
Water Quantity required for cooling or heating
Useful HVAC Formulas
1 kg = 2.2046 lb
Weight
-1
0
.0
-2.3
-4.6
RY A
GD
ER K
middleeast.johnsoncontrols.com
4.0.0
4
-8.0.0
‡
8
-
2.0
25
30
35
30
0.90
© 2013 Johnson Controls, Middle East.
All rights reserved worldwide.
0
3
Qs
Qt
60
25
30
0.88
Middle East Regional Head Quarter
P.O. Box 31065, Suite 1304, API World Tower
Sheikh Zayed Road, Dubai, UAE
0.5
SENSIBLE HEAT
TOTAL HEAT
-‡
80
90
UME
MET
Panoptix™ and Central Plant Optimization™ are trademarks of Johnson Controls, Inc. in
the United States of America and other countries. Other trademarks used herein may be
trademarks or registered trademarks of other companies.
3
0.6
1.0
2
3
70
2400 m 0.743
1800 m 0.801
1200 m 0.864
600 m 0.930
10
0
103.2 X Percent of Pump efficiency
flow (l⁄s) X Head (m) X Specific Gravity
OL
.86 V
IC
CUB
Johnson Controls, the Johnson Controls logo, Metasys® and YORK® are registered
trademarks of Johnson Controls, Inc. in the United States of America and other countries.
For more information contact your local
Johnson Controls representative or visit us at
middleeast.johnsoncontrols.com
CONTACT JOHNSON CONTROLS
0.8
1.0
1 Gallon (U.S.) = 3.785 dm (liter) = 0.13368 ft = 0.8327 Imp. gal (UK)0
Volume
1 ft/s = 0.3048 m/s
Velocity
‡
101.325
o
F) = 0.048 Btu/(in
h oF) kPa
1 W/(m K)BAROMETRIC
= 0.5779 Btu/(ft hPRESSURE:
0.4
7.0
We have a long history of partnering
with public and private entities to deliver
innovative, guaranteed solutions that
meet your triple bottom line. Create
quality environments. Maximize energy
and water efficiency. Provide clean,
renewable energy. And save millions!
2
SEA LEVEL
Thermal Conductivity
4.7
11.7
ENERGY SOLUTIONS
2
SI= Units
1 mm water
9.81 Pa (N/m2)
5
Normal Temperature
1 bar = 1x10 Pa (N/m ) = 10.20 m H O = 0.98692 atm = 14.5038 psi (lbf/in )
Pressure
0.3
Altitude Air Density Ratio at 21 oC
Pump kw =
Latent Heat kW = 3010 x m3/s x Δw (kg water/kg dry air)
Sensible Heat kW = 1.23 x m3/s x Δt (0C)
Cooling / heating capacity
P1 / P2 = (Speed 1 / Speed 2)3
Power
SP1 / SP2 = (Speed1 / Speed2)2
Head or Pressure
Volume1 / Volume2 = (Speed1 / Speed2)
Volume
If the wheel diameter is constant
Pump Power
PSYCHROMETRICTotal Heat kW = 1.20 x m /s x Δh ( Enthalpy kJ/kg)
CHART
1 m (meter) = 3.2808 ft = 39.37 in
Johnson Controls offers a broad range
of Aftermarket services that can be
combined in numerous ways to create
integrated, flexible and customized
solutions tailored to meet your specific
needs. We work with our clients to
develop and implement strategic
performance improvement solutions that reduce costs and risks,
while maximizing efficiency and utilization.
1 in (inch) = 25.4 mm = 2.54 cm
Length
1 Btu/ft 2 h oF = 5.678 W/m2 K = 4.882 kcal/h m2 oC
Heat Transfer coefficient
1 ton of refrigeration = 12,000 Btu/hr = 3.51 kw
1 hp = 0.74570 kW
1 kW (kJ/s) = 859.9 kcal/h = 3,413 Btu/h
AFTERMARKET
A smarter way to build. Create more
productive, intelligent building environments
through our holistic approach to building
construction. Seamlessly integrate critical
building and business technologies and
systems from a single source while
minimizing risk and reducing infrastructure
and systems duplication.
Heat Flow (Power)
0.2
TECHNOLOGY CONTRACTING
1 m2 = 1550 in2 = 10.764 ft 2
Fan Law
OG
Area
Useful Unit Conversion Factors
0.1
T
Normal Temperature - SI Units - Barometric Pressure: 101.325 kPa
PY
C
Psychrometric Chart
W
ET
LB
40
2%
4%
6%
R
8%
%
15
RE
45
40
U
C
-°
H
IVE
T
A
EL
TU
RA
M
PE
TE
ITY
MID
50
2
4
6
8
10
12
14
16
18
20
22
24
26
28
0.25
0.30
0.35
SENSIBLE HEAT RATIO = Qs / Qt
BU
0.20
25
%
Featuring an open-platform and
cloud-hosted application suite, the
Panoptix solution simplifies the process of
collecting data from a variety of building
systems to provide a single, integrated
view of building and system performance.
HUMIDITY RATIO - GRAMS MOISTURE PER KILOGRAM DRY AIR
PANOPTIXTM BY JOHNSON CONTROLS
T
EN
R
AIR
DR
Y
OF
RA
M
KIL
PE
-K
J
HA
L
A
UR
SA
T
TE
TIO
N
90
%
-°
UR
E
RA
MP
E
80
%
3.5
70
%
2.3
0
60
%
-00.5.4
- .3
-0
-0.2
-0.1
0
-2.
0
-1.
55
50
-10
-5
0
5
10
15
20
25
30
13.0
1.00
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
14.0
0.95
15.0
16.0
0.85
0.90
17.0
18.0
19.0
20.0
21.0
22.0
23.0
24.0
25.0
26.0
27.0
28.0
29.0
30.0
31.0
32.0
33.0
34.0
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
SENSIBLE HEAT RATIO = Qs / Qt
0.92
0.80
0.78
0.74
60
70
80
90
10
0
11
0
12
0
13
0
ENTHALPY - KJ PER KILOGRAM OF DRY AIR
VAPOR PRESSURE - MM OF MERCURY
DEW POINT TEMPERATURE - °C
Download PDF