RadiSys ATCA-5400 RTM Specifications

Add to my manuals
88 Pages

advertisement

RadiSys ATCA-5400 RTM Specifications | Manualzz

PROMENTUM

®

ATCA Firmware and Software Update Instructions

October 2011 007-03278-0009

Revision history

Version

-0000

-0001

-0002

-0003

-0004

-0005

-0006

-0007

-0008

-0009

Date

May 2008

October 2008

January 2009

March 2009

July 2009

November 2009

August 2010

November 2010

June 2011

October 2011

Description

First edition.

Second edition. Minor revisions.

Third edition. Several updates

Fourth edition. Minor updates.

Fifth edition. Several updates.

Sixth edition. Minor revisions.

Seventh edition. Multiple revisions.

Eighth edition. Miscellaneous updates.

Ninth edition. Multiple updates.

Tenth edition. See What’s new in this manual on page 5 for details about changes in this version.

© 2008‐2011 by Radisys Corporation. All rights reserved. 

Radisys and Promentum are registered trademarks of Radisys Corporation. All other trademarks, registered trademarks, service marks, and  trade names are the property of their respective owners.

Table of Contents

Preface ................................................................................................................................................ 5

About this manual........................................................................................................................................5

What’s new in this manual...........................................................................................................................5

Where to get more product information .......................................................................................................5

About related Radisys products...................................................................................................................5

Related documents......................................................................................................................................6

Notational conventions ................................................................................................................................6

Electrostatic discharge ................................................................................................................................6

Chapter 1: Introduction to the update process................................................................................ 7

Overview of the update process ..................................................................................................................8

Upgrade support policy..............................................................................................................................11

Chapter 2: Performing an update using rfw-update...................................................................... 13

Step 1: Plan the update .............................................................................................................................13

Step 2: Obtain the update bundles from Radisys ......................................................................................17

Step 3: Prepare the Linux host ..................................................................................................................18

Step 4: Update IPMC FPGA devices.........................................................................................................20

Step 5: Create a configuration file (conf.rfw) .............................................................................................21

Step 6: Update the AMC-7211 and AMC-7212 .........................................................................................25

Step 7: Run the rfw-update utility ..............................................................................................................26

Step 8: Rediscover the shelf......................................................................................................................29

Step 9: Update remaining components .....................................................................................................30

Chapter 3: Using rsys-update for single product updates ........................................................... 31

rsys-update command options...................................................................................................................32

rsys-update help ........................................................................................................................................33

Using URLs with rsys-update ....................................................................................................................33

Using full path lists.....................................................................................................................................34

Using local directories ...............................................................................................................................34

Updating all redundant components on a single module...........................................................................34

Updating non-redundant devices...............................................................................................................35

Chapter 4: Updating ATCA-45xx CPMs .......................................................................................... 37

Installing the required OS RPM packages.................................................................................................37

Installing the BIOS update driver for rsys-update ......................................................................................41

3

Chapter 5: Setting the CPM boot block jumpers ........................................................................... 43

ATCA-4300 and ATCA-4310 CPM ............................................................................................................43

ATCA-4500, ATCA-4550, and ATCA-4555 CPM ......................................................................................44

Chapter 6: Board-level updates for the ATCA-45xx CPM and RTM ............................................. 46

Updating the BIOS.....................................................................................................................................46

Updating the IPMI firmware and FPGA for ATCA-4500, ATCA-4550, and ATCA-4555 ............................48

Updating the IPMI firmware for ATCA-4580 ..............................................................................................50

Updating the CPM FRU.............................................................................................................................53

Updating the EEPROM for ATCA-4500, ATCA-4550, ATCA-4555 ...........................................................54

Updating the EEPROM for ATCA-4580.....................................................................................................56

Updating the SAS firmware for ATCA-4580 ..............................................................................................57

Updating the legacy FPGA and SPI flash for ATCA-4500, ATCA-4550, and ATCA-4555.........................58

Updating the RTM MMC firmware, FRU, and alarm CPLD .......................................................................60

Updating the RTM SAS firmware...............................................................................................................65

Downgrading a CPM to an earlier firmware version ..................................................................................66

Chapter 7: Updating and customizing FRU data ........................................................................... 68

Customizing FRU-specific data .................................................................................................................68

Updating FRU data using fru_update ........................................................................................................70

Chapter 8: Updating IPMI FW and FRU data for an AMC or RTM................................................. 72

Determining the IPMI firmware version......................................................................................................72

Updating the IPMI firmware .......................................................................................................................73

Reverting to backup firmware....................................................................................................................74

Updating AMC or RTM FRU data..............................................................................................................75

Chapter 9: Installing previous firmware or software versions ..................................................... 76

rfw-merge command details ......................................................................................................................76

Appendix A: Sample conf.rfw file ................................................................................................... 78

Configuration file syntax ............................................................................................................................78

Formatting guidelines for conf.rfw .............................................................................................................80

Small sample conf.rfw file..........................................................................................................................82

Full sample conf.rfw file .............................................................................................................................83

Appendix B: IPMB and IPMB-L address mapping ......................................................................... 85

Appendix C: Power cycling after IPMC FPGA upgrades .............................................................. 88

4

Preface

About this manual

ATCA systems running Promentum version 3.5.0 or earlier must be upgraded to version 4.0.0  by following the Promentum 3.x to 4.x Firmware and Software Upgrade/Downgrade 

Instructions.

The update instructions in this document can be used only after all system modules have  been upgraded from Promentum version 3.x to version 4.0.0.

What’s new in this manual

• Added the contents of the ATCA‐4500, ATCA‐4550, ATCA‐4555 FW‐SW Upgrade 

Instructions and the ATCA‐4580 FW‐SW Upgrade Instructions

• Added power cycle requirements for IPMC FPGA upgrades (Appendix C)

• Added the upgrade compatibility support policy (Appendix D)

Where to get more product information

Visit the Radisys Web site at  www.radisys.com

  for product information and other resources. 

Downloads (manuals, release notes, software, etc.) are available at  www.radisys.com/downloads .

For additional information about new features, resolved issues, and known limitations in the  latest Promentum software release, refer to the Promentum product release notes.

See the following documents for additional firmware and software update information:

• Promentum 3.x to 4.x Firmware and Software Upgrade/Downgrade Instructions

• Promentum ATCA Firmware and Software Update Instructions using the Radisys Software 

Management Framework

For information about the PCI Industrial Computer Manufacturers Group (PICMG ® ) and the 

AdvancedTCA standard, consult the PICMG Web site at this URL:  http://www.picmg.org

.

About related Radisys products

For information on the Promentum product family and other Radisys products, see the 

Radisys Web site at  www.radisys.com

5

Preface

Related documents

• Promentum 3.x to 4.x Firmware and Software Upgrade/Downgrade Instructions

• Promentum ATCA Firmware and Software Update Instructions using the Radisys Software 

Management Framework

Notational conventions

This manual uses the following conventions

BoldText

ItalicText

MonoText

BoldMonoText

ItalicMonoText

Brackets [  ]

Curly braces { }

Vertical line |

A keyword. 

File, function, and utility names. 

Screen text and syntax strings. 

A command to enter. 

Variable parameters. 

Command options. 

A grouped list of parameters. 

An “OR” in the syntax. Indicates a choice of parameters. 

All numbers are decimal unless otherwise stated.

Electrostatic discharge

W ARNING !  Radisys products contain static‐sensitive components and should be handled with care. 

Failure to employ adequate anti‐static measures can cause irreparable damage to components.

Electrostatic discharge (ESD) damage can result in partial or complete device failure, performance  degradation, or reduced operating life. To avoid ESD damage, the following precautions are strongly  recommended. 

• Keep each module/PCB in its ESD shielding bag until you are ready to install it.

• Before touching a module, attach an ESD wrist strap to your wrist and connect its other end to a  known ground. 

• Handle modules only in an area that has its working surfaces, floor coverings, and chairs  connected to a known ground.

• Hold modules only by their edges and mounting hardware. Avoid touching PCB components and  connector pins.

For further information on ESD, visit  www.radisys.com/esd .

6

Chapter

1

Introduction to the update process

A remote firmware update utility, rfw‐update, is provided with the latest ATCA release. The 

rfw‐update utility remotely invokes instances of the rsys‐update tool on specified modules for  significantly faster and easier updates of firmware and software components.

Using rfw‐update, shelf‐ and system‐wide upgrades can be initiated with a single command  from one host, such as an external Linux host or an ATCA‐4500 CPM. Updates can be  performed on live systems, and the only downtime for the modules is typically for rebooting  to activate the new code. In some cases, a module may need to be reinserted and an  additional reboot may be required to complete the update.

The rfw‐update utility can update both the redundant and non‐redundant module  components. It uses a configuration file defined by the update administrator that identifies all 

Promentum ATCA components to update. The rsys‐update utility then systematically updates  the identified components. 

The rfw‐update utility also ensures that the running configuration is preserved across the  update. See 

Save your configuration on page 15

 for details.

The rsys‐update utility inspects existing software and firmware versions so it can determine  the best order to upgrade components and skip components that already have the latest  version. Modules can be updated in parallel, dramatically reducing the time required to  update a system.

See 

About rsys‐update and rfw‐update on page 8  for a detailed list of the capabilities and 

usage for rsys‐update and rfw‐update.

Note: Some upgrades may require an initial upgrade to an intermediate release version before 

completing the upgrade to the intended version. See  Upgrade support policy on page 11  for 

details regarding the Radisys upgrade support policy.

7

Introduction to the update process 1

Overview of the update process

Using rfw-update to update one or more Promentum shelves

The basic procedure for updating one or more Promentum shelves is as follows. Additional  information about each step is provided in this document.

1. Plan the update by reading this document and identifying the products to update. See 

page 13

.

2. Obtain the update bundles from Radisys. See 

page 17

.

3. Prepare the Linux host where rfw‐update will be run. See 

page 18

.

4. Update IPMC FPGA devices where required. See  page 20 .

5. Create a configuration file to identify the Promentum ATCA products to update, along with 

their IP addresses and basic update order. See  page 21 .

6. Run the rfw‐update utility to start the update. See 

page 26

.

Note: The rsys‐update utility can still be used for individual module updates. See 

page 31

.

7. From the ATCA‐2210 SCM that is running the active Shelf Manager, issue a  rediscoverShelf  command to make sure the HPI RPT information is synchronized with  the new versions running in the system. See 

page 29

.

About rsys-update and rfw-update

rsys-update

• Utility for updating the firmware banks on a single module

• Must be invoked twice to update both sets of banks

• Runs on the module being updated or its front module, such as the ATCA‐2210 SCM for  the ATCA‐5010 or ATCA‐5014 SPM

• User specifies a path or URL to the upgrade bundle

• Updates the standby banks of each component and then activates them as a set; by  default, the tool skips updates when the bank and file versions match, but does not skip  activation

• Supplied as bash source, allowing easy local enhancement

See 

Chapter 9, Installing previous firmware or software versions, on page 76  for details about 

the rsys‐update command options used in this document.

8

Introduction to the update process 1 rfw-update

• Utility for updating multiple remote modules by invoking rsys‐update on each module

• Runs on a host that is NOT being updated, such as a CPM or Linux server

• User supplies a configuration script that specifies the following “upgrade campaign:”

• The modules to upgrade, how to access them, and what firmware to install

• Optional override of upgrade order and which upgrades are processed in parallel

• Optional checks to verify chassis number, slot number, active bank and/or switch  banks prior to update

• Can update both sets of banks on all accessible modules via a single command invocation

• Verifies the updated firmware matches the file versions after each activation

• Supplied as Perl source, allowing easy local enhancement

Figure 1  shows the rfw‐update and rsys‐update process flow.

Figure 1. The rfw-update and rsys-update process flow

Linux host rfw-update

System software upgrade framework run from an external host

Configuration file

(conf.rfw) reflash

Local LMP software upgrade tool

Module 1 rsys-update

Single module upgrade tool run on the target module rsys-ipmitool

IPMC subsystem upgrade tool

Other local basic update utility

Module 2 rsys-update run on the target module

Module n rsys-update run on the target module

9

Introduction to the update process 1

Components supported by rfw-update

ATCA modules typically have a number of firmware and software components that can be  updated. These components are programmed into flash devices or logic devices like FPGAs  and CPLDs. Some of the devices act as redundant active‐standby pairs that are updated one at  a time. Other devices are single, non‐redundant units. The devices in which software and  firmware components are stored are referred to as “banks“ in this document.

Table 1  lists the components that can be updated automatically by rfw‐update. Components  with a second bank can store a fall‐back image. The second bank is also used as a staging area  for installing the new image while running the old image. 

For a list of manually updated components, see 

Step 9: Update remaining components on  page 30

.

Table 1. ATCA components supported by rfw-update

Applicable modules Component description

Linux and U-Boot image

Number of banks

2

Redundant/

Non-redundant

R

Configuration saved automatically?

Yes a ATCA-1200

ATCA-2210

ATCA-7220

ATCA-9100

ATCA-1200

ATCA-2210

ATCA-4300, ATCA-4310

ATCA-4500, ATCA-4550, ATCA-4555

ATCA-5010

ATCA-5014

ATCA-7220

ATCA-9100

ATCA-4300, ATCA-4310

ATCA-4500, ATCA-4550, ATCA-4555 e

ATCA-7220

AMC-7211

AMC-7212 d

IPMC FRU info

IPMC application

IPMC boot block

IPMC FPGA

CPU BIOS

CPU BIOS boot block

DPB FPGA c

DPB boot flash c

SFP+ converter SEEPROM 1

Boot flash 1

1

1

2

2

1

1

1

2

R

R

NR

NR

NR

NR

R

R

NR

R

No b

No b

No

N/A

N/A

N/A

Yes

N/A

N/A

N/A c d a b e

For the ATCA-7220 PPM, the data flow mode selection is not preserved automatically. See the ATCA-7220 Packet

Processing Module Reference.

Use the Linux utility bioscli to save and restore the configuration for the ATCA-4300 and ATCA-4310. Use the bioscli2 utility to save and restore the configuration for the ATCA-4500, ATCA-4550, and ATCA-4555 CPMs. For more information, see the Compute Processing Module Reference for the CPM.

The DPBs must be running on either U-Boot or Linux.

See Step 6: Update the AMC-7211 and AMC-7212 on page 25 for update instructions for the AMC-7211 and the AMC-

7212.

For the ATCA-4500, ATCA-4550 and ATCA-4555 CPM, not all components can be upgraded using rfw-update and rsys-

update. See

Chapter 6, Board-level updates for the ATCA-45xx CPM and RTM, on page 46 for details.

10

Introduction to the update process 1

Upgrade support policy

This section describes the Radisys general support policy regarding upgrade version  compatibilities when upgrading from one ATCA system release version to another. This  general support policy outlines which upgrades can be completed without requiring an  intermediate step, and which do require an intermediate upgrade step.

Undiscovered defects in previous releases may prevent Radisys from meeting these upgrade  objectives. Any deviation from this policy will be noted in the release notes for that release.

Note: In some cases, an example may not refer to a specific Promentum release. Contact 

Radisys Support for applicable releases for that situation.

Upgrades not requiring an intermediate step

• From the previous minor release

Example: Upgrading ATCA 3.7.0 to ATCA 3.8.0.

• From the previous maintenance release

Example: Upgrading ATCA 4.1.1 to ATCA 4.1.2.

• From maintenance releases between the previous minor release and the previous  maintenance release

Example: Upgrading ATCA 4.1.1 to ATCA 4.1.x.

• From the latest maintenance release of the previous major series

Example: Upgrading ATCA 3.x.x to ATCA 4.2.0.

(ATCA 3.x.x is the latest maintenance release for the ATCA 3.x.x series)

• From the factory‐programmed versions in place at the time of the software release

Example: Upgrading the current manufacturing programmed version of ATCA 4.0.0 to 

ATCA 3.8.0.

Upgrades requiring an intermediate step

• From specific older major releases:

• Upgrading ATCA 3.5.0 to ATCA 4.2.0 requires an intermediate upgrade step to the  latest 3.x.x maintenance release.

• Upgrading ATCA 3.5.3 to ATCA 4.1.1 requires an intermediate upgrade step to ATCA 

4.0.0 first.

• From specific older minor releases in the same major series

Example: Upgrading ATCA 4.0.0 to ATCA 4.2.0 requires an intermediate upgrade step to  the latest minor release (ATCA 4.1.0).

11

Introduction to the update process 1

• From a maintenance release from an older minor release series

Example: Upgrading ATCA 4.1.1 to ATCA 4.x.x requires an intermediate upgrade step to 

ATCA 4.2.X first.

• From a patch release, which requires an upgrade to the next maintenance release

Example: Upgrading ATCA 4.1.1.3 to ATCA 4.2.0 requires an upgrade to ATCA‐4.1.2 first.

Note: Patch releases are intended to be short‐term releases that are replaced by the next  maintenance release.

12

Performing an update using rfw-update

Chapter

2

This chapter describes the use of the rfw‐update remote firmware update utility.

Step 1: Plan the update

Identify the products you want to update

For each Promentum platform, list all installed ATCA modules (except a CPM if it acts as the 

Linux host for running rfw‐update). For each of the modules, list the slot where it is installed  and the connection IP address (for Telnet or SSH access). For example:

Rack #12, Shelf #1: Promentum SYS‐6010

Slot 1: ATCA‐1200; telnet://[email protected]

Slot 2: ATCA‐7220; telnet://[email protected]

Slot 3: ATCA‐7220; telnet://[email protected]

Slot 4: ATCA‐9100; telnet://[email protected]

Slot 5: ATCA‐9100; telnet://[email protected]

To find the IP address of the module to upgrade, log onto the module and enter this  command: ifconfig

Note: The rfw‐update utility ensures that module IP addresses are preserved after a reboot.

13

Performing an update using rfw-update 2

Slot Name

You can print this page and record the module data in this table before running the update:

IP Address User:Password

Connection

Type String

W

ARNING

Do not include a CPM that is acting as the Linux host for rfw‐update in the list of  modules to update. Instead, update the CPM manually before or after updating all other shelf  components. See 

Chapter 3, Using rsys‐update for single product updates,  on page 31

.

Determine when to perform the update

Update planning should take into account the time needed to perform the update and the  downtime involved.  Figure 2 on page 23  shows an example of the time it took to perform an  update after all preparation work was done. In the example—which was optimized to perform  many updates in parallel—it took about 90 minutes after the update command was issued to  update a fully‐populated ATCA‐6000 12U 14‐slot shelf. The actual time it takes on your system  will vary depending on the phases defined in the configuration, networking speed, IPMB  traffic, and JFFS access speed.

The firmware and software updates are done on live systems, so downtime is limited to  reboots that take approximately 24 minutes for all modules in the shelf. 

14

Performing an update using rfw-update 2

Save your configuration

The rfw‐update utility preserves default configurations across updates for the ATCA‐1200, 

ATCA‐2210, ATCA‐7220, and ATCA‐9100. Configurations are preserved in both banks to retain  the existing setup information. Each ATCA software release image contains a list of files to be  preserved, and you can generate a custom list to specify additional files within the /etc  directory to preserve.

File preservation works as follows:

• Before the OS update begins, the configuration is copied from the active flash bank to the  standby flash bank.

• After the update is activated, the module reboots to the standby bank.

• During boot up:

• the saved configuration is saved to a temporary location,

• the directories /rsys/onboot.d and /rsys/onboot.data are removed and repopulated by  the new release, and

• the configuration saved in the temporary location is restored to its proper location.

Files preserved by default

File preservation includes various configurations, such as Ethernet (fastpath), module  management, shelf management, and others. The system automatically preserves the  following files in a default preservation list stored in the  /etc/configmgmt.sh

 file:

/etc/fastpath/fastpath0.cfg

/etc/fastpath/fastpath1.cfg

/etc/fastpath/fastpath.cfg

/etc/snmp/snmpd.conf

/etc/snmp/snmptrapd.conf

/etc/syslog.conf

/etc/ntp.conf

/etc/passwd

/etc/group

/etc/mcli/mclid.cli

/etc/var/lib/snmp/snmpd.conf

/etc/snmp/snmp.conf

/etc/snmp/snmpWatchdog.conf

/etc/snmp/hpiSubagent.conf

/etc/shmgr.conf

/var/lib/shmgr/ShelfFruCopy.bin

/var/lib/shmgr/hcf.tgz

/root/.snmp/snmp.conf

/etc/shmgralarm.conf

/etc/fruinfo.conf

/var/lib/shmgr/atca‐6002.bin

15

Performing an update using rfw-update 2

For the ATCA‐7220, the rsys‐update utility creates a custom preservation list at  /etc/rsys‐ user‐file‐list.cfg

 during the update process if the file does not already exist. The rsys‐

update utility adds the following ATCA‐7220 configuration files to that custom preservation  list:

/etc/octeon.conf

/etc/fpga/ppm20fpga.conf

All files in /etc/octeon

Creating a custom preservation list

Other files may need to be preserved. For example, on an ATCA‐2210 SCM running a DHCP  server, you might preserve the DHCP configuration files.

Additional preserved configuration files must be added to the  /etc/rsys‐user‐file‐list.cfg

  file. This file may need to be created the first time custom files need to be preserved.

When adding files, make sure each file name is on its own line in  rsys‐user‐file‐list.cfg

  and includes the full path. For example, these commands add the xxx.cfg and yyy.cfg files to  the custom preservation list: echo "/etc/xxx.cfg" > /etc/rsys‐user‐file‐list.cfg

echo "/etc/yyy.cfg" >> /etc/rsys‐user‐file‐list.cfg

Save the file when the additions are complete.

Preserving other files and configurations manually

Most files outside of /etc cannot be preserved by the tools. Consider whether to manually  save the files you have created outside of  /etc , such as the DHCP leases file.

To preserve configuration files outside the  /etc  directory, add them to the 

/rsys/onboot.data/overlay  directory and reference them in the  /etc/rsys‐user‐file‐ list.cfg

 file.

An alternative method for manually saving files is to copy the files to a remote server (using 

FTP, SFTP, or TFTP) before updating. Copy them back to the module after the update is  complete.

Note: Use FTP or SFTP to achieve the best performance and reduce the update time.

For the ATCA‐7220 PPM, data flow mode selection is not preserved automatically. For details  on mode configuration, refer to the ATCA‐7220 Packet Processing Module Reference.

Saving custom configuration data

Any custom configuration data must be explicitly saved or it will be lost when a module  reboots. The default preservation list is automatically saved.

Before continuing with a firmware or software update, save any custom preservation list 

changes as described in  Creating a custom preservation list

, above.

16

Performing an update using rfw-update 2

Determine which modules require an IPMC FPGA update

IPMC FPGA devices should be updated separately using rsys‐update before running rfw‐

update to automatically update the other module components. This separate update is  required so the rfw‐update process runs without interruption and does not require manual  user intervention.

The IPMC FPGA update is required only if the installed version of the IPMC FPGA differs from  the version provided with the latest software release. Follow these steps to determine which  modules require IPMC FPGA updates:

1. Check the IPMC FPGA version on each system module by running the following command  on the ATCA‐2210 LMP command line: rsys‐ipmitool ‐t <module IPMB address> hpm check

See 

Table 6   on page 86

 for the IPMB addresses of all IPMCs in the system.

2. Determine the current version of the IPMC FPGA firmware. This information is listed in the  product revision levels table of the current Promentum software release notes. The  release notes are available on the Promentum software product media.

See 

Step 4: Update IPMC FPGA devices on page 20

 for IPMC FPGA update instructions.

Step 2: Obtain the update bundles from Radisys

The latest Promentum software image may be available at  www.Radisys.com/downloads . 

Browse to the Promentum SYS‐6014/SYS‐6016 downloads page and download the 

Promentum software release ZIP file from the Software downloads section. Extract the ISO  image and optionally create a DVD containing the module update bundles. Contact Radisys 

Support for the Promentum image if the latest version is not available on the Radisys web site.

For each module supported by rfw‐update, the image contains:

An update bundle ending in firmware.tgz. The update bundle package is optimized for  the rsys‐update and rfw‐update tools. The package should only be used when upgrading  using rsys‐update and rfw‐update. The update bundle also contains the latest version of  the rsys‐update and rfw‐update utilities, as well as scripts to perform the update. Multiple  update bundles are provided when multiple operating systems are supported. 

A user bundle ending in <version>.tgz. This file is a package containing the tools,  supporting applications, source files, and documentation needed for development. The  user bundle .tgz file is usually of significant size.

Note: The firmware updates for the ATCA‐5010 and the ATCA‐5014 SPMs are included in the 

ATCA‐2210 firmware update bundle. 

17

Performing an update using rfw-update 2

Step 3: Prepare the Linux host

Prerequisites

The host system that runs rfw‐update must be a Linux host with LAN access to the modules  installed in the shelf. The host system must be running Perl version 5.8.5, and specific Linux, 

Radisys, and Perl RPMs must also be installed. See 

Getting required packages  for the list of 

required RPMs. 

All update targets must be accessible from the host running rfw‐update. An ATCA‐4500 CPM  in the shelf to be upgraded can be used for this purpose.

Radisys has validated rfw‐update on a Dell™ PowerEdge™ 1U server running Red Hat® 

Enterprise Linux 4. The rfw‐update utility is also supported on Wind River Platform for 

Network Equipment, Linux Edition, version 1.4, and on Monta Vista® Linux, Carrier Grade 

Edition 5.

Getting required packages

Preparing the host requires installing Linux RPM packages from the Promentum image. You  can find the RPMs by decompressing the CPM file ending in <version>.tgz. The RPMs for each 

supported OS are located under the packages directory. See  Preparing the host system on  page 18

 for details on decompressing the <version>.tgz file.

This Radisys RPM is required for use of the rfw‐update utility:

• rfw‐update‐<version>.noarch.rpm

These Perl RPMs are also needed by rfw‐update:

• perl‐YAML

• perl‐Expect

• perl‐IO‐Tty

• perl‐Net‐Telnet

• perl‐Inline

Preparing the host system

1. Verify that Perl is installed on the host system by entering: perl ‐v

Notes:

• If Perl is not installed on your system, install it according to your vendor instructions.

• If the version of Perl you are using is not 5.8.5, enter the following command: export PERL5LIB=/usr/lib/perl5/5.8.0/:$PERL5LIB

The  export  command assigns the path /usr/lib/perl5/5.8.0 to the PERL5LIB  environment variable. The rfw‐update utility places Perl modules in the 

/usr/lib/perl5/5.8.0/ directory, so configuring PERL5LIB helps rfw‐update find the  modules. 

18

Performing an update using rfw-update 2

2. Install the latest RPM packages.

a. Locate the <version>.tgz file appropriate for your operating system in the Promentum 

CD image, as explained in 

Getting required packages on page 18

. Copy the 

<version>.tgz file to a temporary directory on the Linux host. Choose a path and name  that can be easily accessed for the remaining steps.

b. Decompress the <version>.tgz file by entering the following command from within the  temporary directory: tar ‐xzvf <version>.tgz

This creates a directory named <version> in the temporary directory.

c. Install or update the Perl RPMs by entering:

rpm ‐Uhv <path_to_packages>/perl‐*

The system will announce if any RPMs are already installed.

3. Install the rfw‐update RPM package appropriate for your host from the Promentum  software image. Locate, copy, and install the rfw‐update RPM in a similar way to the Perl 

RPMs in  Step 2 .

rpm ‐Uhv <path_to_packages>/rfw‐update‐*

4. (Optional) When using a CPM as the host, manually update the firmware and BIOS images 

on the host using rsys‐update. For more information, see  Chapter 3, Using rsys‐update for 

single product updates, on page 31 .

19

Performing an update using rfw-update 2

Step 4: Update IPMC FPGA devices

IPMC FPGA devices for modules must be updated separately using rsys‐update before running 

rfw‐update to automatically update the other module devices. Refer to the product release  notes to identify any IPMC FPGA updates.

Follow these steps to perform the update:

1. Determine which modules require IPMC FPGA updates by comparing their installed IPMC 

FPGA version with the latest Promentum software release. See  Determine which modules 

require an IPMC FPGA update on page 17

 for details.

2. Run rsys‐update on each module that requires an IPMC FPGA update, specifying the path  to the firmware update bundle. The following command updates the module’s IPMC FPGA  and associated IPMI firmware: rsys‐update ‐‐path <xxx‐firmware.tgz> ‐‐ipmi‐firmware:update

Note: See  rsys‐update command options on page 32

 for details about the rsys‐update  command options used in this document.

To update the IPMC FPGA for the ATCA‐5010 or ATCA‐5014 SPM, run the following  command from the ATCA‐2210 and specify the IPMB target address (0xE4 for the SPM in  slot 7, or 0xE6 for the SPM in slot 8): rsys‐update ‐‐path <xxx‐firmware.tgz> ‐‐ipmi‐firmware:update ‐‐ipmb‐target

<IPMB target address>

3. Activate the updated component: rsys‐update ‐‐path <xxx‐firmware.tgz> ‐‐ipmi‐firmware:activate

Similarly, activate the updated component for the ATCA‐5010 or ATCA‐5014 SPM: rsys‐update ‐‐path <xxx‐firmware.tgz> ‐‐ipmi‐firmware:activate ‐‐ipmb‐target

<IPMB target address>

4. Remove and reinsert the module.

Note: If the module power‐cycles then it does not need to be removed. Some modules  with release 3.5.0 or greater Promentum software will power cycle automatically, so  removal and reinsertion is not required.

See  Appendix C, Power cycling after IPMC FPGA upgrades, on page 88

 for details about the  modules that may require a manual power cycle.

See 

Chapter 3, Using rsys‐update for single product updates, on page 31  for additional 

information about using rsys‐update for individual updates.

20

Performing an update using rfw-update 2

Step 5: Create a configuration file (conf.rfw)

The rfw‐update utility uses a configuration text file to specify which modules should be  updated and whether they will be updated in parallel with other modules to save time. The  text file can be any name, but it is named conf.rfw in this document.

The conf.rfw file contains a list of bundles with URL paths and a list of update targets with 

Telnet connect strings. The update target connect string contains the IP address and, if  needed, login information to allow a connection from the host to the update target. All  update targets must be accessible from the host running rfw‐update.

The conf.rfw configuration file also identifies the locations of the update bundles. The bundles  in the conf.rfw file must contain valid URL paths from each target to update bundles  somewhere on the system (not necessarily on the host).

The bundles do not need to be in the same location where rfw‐update is run with conf.rfw,  but the bundles must be accessible from the update target using the specified URL. The IP  connections are shown in the following diagram:

Host running rfw-update tftp/ftp/www server containing update bundle

IP address

(example: 10.10.10.1)

Target module

IP address

(example:

10.10.10.2)

W ARNING ! 

Do not include a CPM that is acting as the Linux host for rfw‐update in the   conf.rfw  configuration file. Including the host as an update target would interrupt the update process for  the CPM and potentially for other modules in the shelf. Instead, update the CPM manually using 

rsys‐update either before or after updating all other shelf components. See  Chapter 3, Using  rsys‐update for single product updates,  on page 31 .

The conf.rfw file can be set up to run the update process on modules sequentially or in  parallel. When modules are updated in parallel, they are in the same phase group. See 

Set up 

phase groups on page 22 .

Run  man rfw‐update  for complete information.

Create conf.rfw from example.rfw

You can generate conf.rfw from the example.rfw text file that is available in /usr/share/rfw‐

update/ after the rfw‐update installation. The file is correctly formatted and contains most of  the keys, so edit it as needed and save the file as conf.rfw.

21

Performing an update using rfw-update 2

Create conf.rfw from samples in the appendix

The conf.rfw file can also be created by referring to samples documented in 

Appendix A, 

Sample conf.rfw file, on page 78

. A simple example is provided for reference and general use,  and the detailed example can be used to produce a complete module update list.

Compose and verify the configuration file

1. Use a text editor to create a configuration file. Refer to  Appendix A, Sample conf.rfw file,  on page 78  for a template. See  Configuration file syntax on page 78

 for file setup details.

2. Save the configuration file as conf.rfw to an easily accessible directory and in a location  that can be accessed by the Linux host system where rfw‐update will execute.

3. Use the following commands to verify the format and test the structure and syntax of 

conf.rfw, the connections to each module and bundle, and versions of both.

To see an overview of the update order as you develop the conf.rfw file: rfw‐update ‐‐parse‐only <path_to_conf.rfw>/conf.rfw

Verify the syntax of the configuration file and test the connections to each module: rfw‐update ‐‐quick‐check <path_to_conf.rfw>/conf.rfw

Verify that each target can access the bundles from the module. This command shows the  versions of all bundles and modules: rfw‐update ‐‐versions <path_to_conf.rfw>/conf.rfw

Set up phase groups

The conf.rfw file can be set up to run the update process on modules sequentially or in  parallel. When modules are updated in parallel, they are in the same phase group. A parallel  update is shown in  Figure 2 on page 23 . The gray bars in the diagram show how rfw‐update  performs operations on the node modules simultaneously in different stages of the update  process. 

You can place any update target into a specific phase group using the phase option in conf.rfw

If a phase group is not specified for the update target, the target is placed in its own unique  phase group and the target is updated sequentially. 

W ARNING !

  Place any module that provides network connectivity to other modules in its own  phase group. Otherwise, when the module is rebooted, the update process for the other modules  may be disrupted.

You can see an overview of the update order as you develop the conf.rfw file with the  ‐‐ parse‐only  option. For example: rfw‐update ‐‐parse‐only conf.rfw

22

Performing an update using rfw-update 2

Figure 2. Parallel updates using rfw-update

Quick connect

Verify bundle access and version

SYS-6010 Shelf

1.

ATCA-9100

2.

ATCA-4500

3.

ATCA-4500

4.

ATCA-9100

5.

ATCA-7220

6.

ATCA-9100

7.

ATCA-2210

ATCA-5010/5014

8.

ATCA-2210

ATCA-5010/5014

9.

ATCA-4500

10.

ATCA-4500

11.

ATCA-9100

12.

ATCA-7220

13.

ATCA-9100

14.

ATCA-7220

Update module and verify update

Approximately 90 minutes

Note: Your update time may be longer than this approximation.

The rfw‐update utility uses the following rules to order the update targets:

1. Hub modules (ATCA‐2210 SCMs) with no phase group number specified: each module is  updated sequentially with the entire specified bundle.

2. User‐defined phase groups:

• Each module is updated with the entire specified bundle

• Modules within a phase group are updated in parallel

• One or more modules can be updated per phase group

• Phase updates occur in phase number sorted order

• The phase update is finished when all modules within the phase complete

3. Node modules with no phase group number specified: each module is updated  sequentially with the entire specified bundle.

To update more than one target at a time, manually place a target in a phase group by  defining a phase group number. Specify the same phase group for each target. The valid phase  group range is 0–999.

Note: If an error occurs on any module, the update will not continue to the next phase. 

However, it will finish processing all modules in the phase before the update stops.

23

Performing an update using rfw-update 2

Selecting the update order

The order that modules and components are updated is determined by a number of setups.

• The update order is controlled in the conf.rfw file to establish phase groups.

• The rfw‐update utility uses its own rules to order multiple modules within the phase  groups (see 

Set up phase groups on page 22

 for details).

• The update order may also be controlled by configuring multiple rfw‐update files to run  sequentially. This allows manual updates to occur between steps, if necessary.

When you select an update order, the following constraints should be kept in mind:

• Place a module that provides network connectivity to other modules in its own phase  group. The update process for other modules may be disrupted when the module  reboots.

The default setting is to update both banks of redundant components. See  Updating both  banks

 about this default setting and how to set up conf.rfw to update a single bank.

To update the AMC‐7211 and AMC‐7212, you must apply manual update operations between 

rfw‐update executions, as described in 

Step 6: Update the AMC‐7211 and AMC‐7212 on  page 25

.

Updating both banks

Some updatable components are redundant, which means they have two banks containing  separate firmware loads. By default, the rfw‐update utility automatically updates both banks  to the same firmware using the image in the bundle.

To update a single bank of a redundant component, specify  update‐banks:single  in the  configuration file. See 

Configuration file syntax on page 78

 for details.

If the  update‐banks:single  option is used, see the  set‐bank  option to specify which boot  bank is active during the update. The rfw‐update utility updates the non‐active bank. For  example, if  set‐bank:0  is specified then bank 1 is updated.

24

Performing an update using rfw-update 2

Step 6: Update the AMC-7211 and AMC-7212

The AMC‐7211 and AMC‐7212 are updated as a non‐redundant component as part of the 

ATCA‐1200 update bundle, or from a CPM host. While the AMC flash is a non‐redundant  component, the host support, which is updated at the same time, is not because it resides in  the redundant LMP. Consequently, the host support is only updated in the active LMP and not  in the redundant LMP.

W ARNING ! 

The support for the AMC‐7211 and AMC‐7212 must be installed and operational on  the CPM or ATCA‐1200 before you can update the AMCs. For driver installation details, see the 

Installing software on the carrier section in the Installation Procedure Supplement chapter of  the Promentum Quad Gigabit Ethernet AMC Reference for the AMC‐7211 and AMC‐7212.

Update the LMP and AMC host support

Follow these steps to update the LMP and AMC host support in both AMC flash banks. In this  procedure, bank 0 is the currently active bank and bank 1 is the redundant bank.

1. Run rsys‐update  ‐‐redundant  to update bank 1. The system automatically reboots to bank 

1.  rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic ‐‐redundant

Note: See  rsys‐update command options on page 32

 for details about the rsys‐update  command options used in this document.

2. Manually install the Cavium host support software. The Cavium processors reboot after  the host support software is installed. For installation instructions, see the Updating the 

software section in the Quad Gigabit Ethernet AMC Reference for AMC‐7211 and AMC‐

7212.

3. Run rsys‐update  ‐‐redundant  to update bank 0. The system automatically reboots to bank 

0.

rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic ‐‐redundant

4. Manually install the Cavium host support software.

5. Run rsys‐update  ‐‐non‐redundant  to update the AMC‐7211 or AMC‐7212 Caviums again. 

Now the new active bank (bank 0) is updated with the new Cavium host support.

rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic ‐‐non‐redundant

Update the IPMI firmware and FRU data

See 

Chapter 8, Updating IPMI FW and FRU data for an AMC or RTM, on page 72

 for details  about updating the AMC IPMI firmware and FRU data.

25

Performing an update using rfw-update 2

Step 7: Run the rfw-update utility

Quick start

Follow these steps to verify the system configuration file and update bundles, then run rfw‐

update to automatically update the modules.

Important: You must have root account access for rfw‐update to operate properly.

1. Verify the syntax of the configuration file and test connections to each module: rfw‐update ‐‐quick‐check conf.rfw

2. Verify that each target can access the bundles from the module. Use this command to  show the versions of all bundles and modules: rfw‐update ‐‐versions conf.rfw

3. Enter this command to start the update process: rfw‐update –‐automatic conf.rfw

rfw-update command details

Syntax rfw‐update {tasks} <FILE>

Note: At least one of the following tasks must be specified when rfw‐update is invoked.

{tasks}

‐a, ‐‐automatic

Performs an automatic update.

‐p, ‐‐parse‐only

Reads and verifies the configuration file and displays an overview of the update order.

‐q, ‐‐quick‐check

Quickly connects to the module and performs simple checks to see if it is ready.

‐s, ‐‐show‐tool‐version

Shows tool version information and exits.

‐v, ‐‐versions

Shows version information of all active, standby, and update bundle components,  then exits.

<FILE>

The configuration file (called conf.rfw in this document) can have any name and is the  chassis or network description file for the system.

For more detailed help and syntax for the conf.rfw file, enter the following command: rfw‐update ‐‐man <path to conf.rfw>/conf.rfw

26

Performing an update using rfw-update 2

Examples rfw‐update ‐‐parse‐only conf.rfw

Verifies the syntax of a bundle configuration file and shows an overview of the update  order.

rfw‐update ‐‐quick‐check conf.rfw

Verifies the syntax of a bundle configuration file and connects to each target.

rfw‐update ‐‐versions conf.rfw

Shows the version information for all bundles and modules defined in the conf.rfw file.

rfw‐update ‐‐automatic conf.rfw

Updates all modules using the bundles and targets defined in the conf.rfw file.

Update process

Assumptions

The rfw‐update utility assumes the following:

1. Prior to the update, all modules are in a stable state.

2. Prior to the update, all modules have saved their running configurations.

3. All update targets are reachable from the host machine running rfw‐update.

4. All bundles are reachable from the update target for download.

5. All modules, during and after their update, remain reachable from the host machine  running rfw‐update.

Update passes

The update of each module consists of three passes.

Note: The update process stops and must be restarted if a failure occurs during any step.

1. Quick Module Check Pass can be run with the  ‐‐quick‐check  option.

• Connect to the module

• Verify rsys‐update is not running

• If specified, verify the slot is correct

• If specified, verify the chassis is correct

2. Verify Module Pass can be run using the  ‐‐versions  option.

• Runs Quick Check Pass

• Download the specified bundle

• Run a version check

• If specified, check to make sure the module is in the expected bank

• If specified, boot the module to the expected bank

27

Performing an update using rfw-update

3. Update Module Pass can be run using the  ‐‐automatic  option.

• Runs Quick Check Pass

• Runs Verify Module Pass

• Saves the configuration to the standby bank

• Updates the firmware from the specified bundle to the standby bank

• Reboots to the standby bank

• After reboot, verifies the update was good

• If specified, runs a user‐provided post‐update script

By default, it runs an update on the standby bank and reboots the module

• Saves the configuration to the standby bank

• Updates the firmware from the specified bundle to the standby bank

• Reboots to the standby bank

• After reboot, verifies the update was good

• If specified, runs a user‐provided post‐update script

Log files

Update messages are saved to  ./log/*.log

 unless another directory is specified with the 

‐‐log‐dir  option on the command line.

2

28

Performing an update using rfw-update 2

Step 8: Rediscover the shelf

Log in to the ATCA‐2210 SCM that is hosting the active Shelf Manager. Access the CLI and  enter: platform‐mgmt rediscoverShelf

This ensures that the HPI RPT information is in sync with new versions running in the system.

Recovering from update problems

If you encounter problems with an update, you can usually recover by updating the  component from the redundant bank. Use rsys‐update or component update tools from the  working bank.

If Linux or U‐Boot is corrupted on the ATCA‐1200, ATCA‐2210, ATCA‐7220 or ATCA‐9100, see  the Promentum Software Guide for recovery instructions.

If the CPM BIOS is corrupted in both banks, see the CPM BIOS Crisis Recovery Instructions for  the specific CPM.

Note: Repeat the update process for redundant programmable devices in order to flash the  second bank. This second update is required for the CPMs because the redundant BIOS  feature requires both BIOS banks to be at the same version.

Restoring older firmware or software

To downgrade to a previous version of firmware or software, see  Chapter 9, Installing previous 

firmware or software versions, on page 76 . Refer to the documentation for the version to 

which you are downgrading as well.

See the product revision levels table in the Promentum software release notes for component  version compatibility. The software release notes are available on the latest Promentum  software product media.

29

Performing an update using rfw-update 2

Step 9: Update remaining components

The following products and components are either not supported by rfw‐update and their  updates must be handled separately, or some updates need to be performed manually along  with rfw‐update. Instructions for updating these products and components are included with  the individual component update files, unless otherwise indicated.

For an explanation of the update files provided, see 

Step 2: Obtain the update bundles from 

Radisys on page 17

.

• CE3100 COM Express module (ATCA‐2210 option).

• Advanced Mezzanine Cards: AMC‐3201, AMC‐3202, and AMC‐3203 Hard Drive Storage 

Modules. See 

Chapter 8, Updating IPMI FW and FRU data for an AMC or RTM, on page 72

  for AMC update information.

• ATCA‐1200 RTM. For details, see the Installing software on the carrier section in the 

Installation Procedure Supplement chapter of the Promentum Quad Gigabit Ethernet AMC 

Reference for the AMC‐7211 and AMC‐7212. See 

Chapter 8, Updating IPMI FW and FRU 

data for an AMC or RTM, on page 72

 for IPMI firmware and FRU data update procedures.

• ATCA‐1200 custom drivers and utilities for AMCs, such as the AMC‐7211 and AMC‐7212  host support package. Reinstall the package as described in the Installation Procedure 

Supplement chapter of the Quad Gigabit Ethernet AMC Reference.

AMC‐7211 and AMC‐7212 IPMI firmware. For details, see  Chapter 8, Updating IPMI FW 

and FRU data for an AMC or RTM, on page 72 .

• A CPM if it is used as the host that runs rfw‐update. The rfw‐update utility must not be  configured to update the host on which it is running. The CPM firmware and BIOS can be  updated using rsys‐update before or after using rfw‐update. If not done previously, update  the CPM as described in 

Chapter 3, Using rsys‐update for single product updates, on  page 31

.

• Linux RPM packages provided by Radisys for the CPMs. Refer to 

Step 3: Prepare the Linux 

host on page 18

 for RPM installation instructions. Update the RPMs before running rsys‐

update on the module, as described in  Step 3: Prepare the Linux host on page 18

.

• RCM (Radisys Chassis Manager) for the ATCA‐6014 and ATCA‐6016 shelves.

FRU data for the Promentum shelves. See  Chapter 7, Updating and customizing FRU data,  on page 68

.

• PEM and FAN firmware for the ATCA‐6006 shelf. Refer to the readme files on the 

Promentum software image.

30

Chapter

Using rsys-update for single product updates

3

This chapter describes the rsys‐update utility, with which you can update most components in  a single ATCA module with one command. (See note below.) Use rsys‐update to update a  module that is not updated by rfw‐update, such as a CPM that acts as the host for running 

rfw‐update

Table 1   on page 10  lists the components updated by rfw‐update, which invokes 

multiple instances of rsys‐update during the upgrade process.

Note: The rsys‐update utility is not used to update the ATCA‐4580 CPM. See 

Chapter 6, Board‐ level updates for the ATCA‐45xx CPM and RTM, on page 46

 for ATCA‐4580 update procedures.

Modules running ATCA software (ATCA‐1200/2210/7220/9100) have the rsys‐update utility  installed in the /usr/sbin directory of the module. This allows rsys‐update to start the update  process using scripts contained within the update bundle.

Important: Update the RPMs on all modules before running the rsys‐update utility.

31

Using rsys-update for single product updates 3

rsys-update command options

Table 2   on page 32

 describes the rsys‐update command options that are used in these update  instructions.

Table 2. Command options for rsys-update

Option

Parameters

Description

‐a, ‐‐automatic Update and activate firmware in the factory recommended order (update the redundant components).

Show version information for all active, standby, and update bundle components.

‐v, ‐‐versions

‐‐path <update‐bundle> The URL, full path or directory path to the update bundle.

‐‐redundant Update only the redundant components (components with more than one bank)

‐‐non‐redundant

‐‐both

Component actions

Update only the non-redundant components (components with a single bank)

Update both the redundant and non-redundant components.

‐‐<component>:update Update the component. The standby component is updated if there is a redundant pair.

Example: --ipmi-firmware:update

‐‐<component>:activate Activate the updated component.

‐‐<component>:versions Display the versions of the components.

Qualifiers

‐d, ‐‐dry‐run

‐e, ‐‐erase‐jffs

‐p, ‐‐primary

‐s, ‐‐secondary

‐m, ‐‐ipmb‐host 

<IPMB host address>

Output the steps that the update would run

When updating the system-os component, erase the JFFS2 file system as part of the update operation.

Update the primary flash bank when performing the system-os update.

Update the secondary flash bank when performing the system-os update.

IPMB address of the host module. The default is derived using fruinfo.

‐t, ‐‐ipmb‐target 

<IPMB target address>

IPMB address of the target module to update. The default is --ipmb-host.

32

Using rsys-update for single product updates 3

rsys-update help

Two forms of help are available for rsys‐update if an update bundle is specified in the help  command. Use the help commands to view the rsys‐update command syntax.

Help on retrieving the update bundle

When the rsys‐update help command is entered without specifying an update bundle, the  utility only gives help on how it can be used to retrieve an update bundle. To obtain this help  information, enter this command at the Linux shell: rsys‐update ‐‐help

Help on updating the ATCA module

More detailed help is available when the update bundle is present and specified in the help  command because the bundle contents provide information about which components can be  updated. The help also includes information on how to update the firmware and software  components on the ATCA module. Enter this command at the Linux shell:  rsys‐update ‐‐help ‐‐path <update‐bundle>

Using URLs with rsys-update

The supported URL protocols are SFTP and TFTP. If the wget utility is installed on the module, 

FTP, HTTP, and HTTPS are also supported.

Note: Use FTP or SFTP to achieve the best performance and reduce the update time.

When a URL is specified, the update bundle is downloaded to the module at /<tmp‐ dir>/<update‐bundle>.tgz. The tarball is extracted into the directory /<tmp‐dir>/<update‐ bundle>/. The URL format specifies the method used to copy the bundle from the host to the  module: rsys‐update ‐‐path sftp://<username>@<hostip>/<update‐bundle>.tgz

rsys‐update ‐‐path tftp://<hostip>/<update‐bundle>.tgz

The URL beginning with “sftp” uses SSH for data transfer, and uses the same authentication  and provides the same security as SSH. The process prompts you for passwords or pass  phrases if they are needed for authentication. The file name may contain a host and user  specification to indicate the file is to be copied from that host. The rsys‐update utility assumes  that SSH is available on the remote host.

The URL beginning with “tftp” uses TFTP for data transfer. The rsys‐update utility assumes  that a TFTP server is accessible from the module and the update bundle is in the /tftpboot  directory. 

Note:   If problems occur with the TFTP data transfer, make sure the TFTP server is accessible  from the module. Do this by attempting to connect to the TFTP server using the TFTP utility  from the Linux shell. For best performance, use either FTP or SFTP.

33

Using rsys-update for single product updates 3

Using full path lists

If a full path is specified and the tarball file with a file name ending in “.tgz” exists, the tarball  bundle contents are extracted into the directory /<tmp‐dir>/<update‐bundle>. The format of  the full path is:

 /<tmp‐dir>/rsys‐update/<update‐bundle>.tgz

Using local directories

If a directory is used and the update command exists in the update‐bundle directory, the  directory is used as‐is and no file is extracted. The format of the command is:

 /<tmp‐dir>/<update‐bundle>

Updating all redundant components on a single module

This procedure updates all redundant components on a single module (see  Table 1   on  page 10

). After completing this procedure, proceed to 

Updating non‐redundant devices on  page 35

.

Notes:

• For IPMC FPGA device updates, see 

Step 4: Update IPMC FPGA devices on page 20

 for  specific procedures and commands.

• Using rsys‐update to perform a software downgrade for the ATCA‐2210 may  successfully update bank 1 for the FPGA firmware, but the bank 2 update may fail and  display the error  Error uploading firmware block .

The error may occur because the IPMC firmware prevents the FPGA downgrade process,  since the module could be rendered inoperable. You can ignore this FPGA‐related rsys‐

update error if you perform a software version downgrade on an ATCA‐2210.

• Some CPMs require a jumper setting before the BIOS boot block can be updated. See 

Chapter 5, Setting the CPM boot block jumpers, on page 43 .

To update a module’s redundant components:

1. Log in to the module.

2. Check the active and standby flash bank versions to confirm your decision to update: rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐versions

Note: Throughout these steps, to point to an uncompressed update bundle specify the  ‐‐ path  option to the “.tgz” file instead. For example: 

‐‐path /<tmp‐dir>/rsys‐update/<update‐bundle>.tgz

3. Make sure the module is in the intended bank by using the  ‐‐dry‐run  option of rsys‐

update. This command displays a simulation of the update procedure, and identifies the  current active bank and the targeted update bank.  rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐secondary ‐‐dry‐run ‐‐automatic

34

Using rsys-update for single product updates 3

4. Update the standby flash bank: rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic

This results in a reboot to the standby (newly updated) flash bank.

5. For local management processor (LMP) modules, confirm the new version works  correctly: flashver ‐‐secondary

6. Download the update bundle again, since the temporary storage was lost upon reboot. 

Refer to the previous section for detailed instructions.

7. Flash the remaining (original active) flash bank.

rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic

This results in a reboot to the original active (now updated) flash bank.

8. Repeat the update process for redundant programmable devices in order to flash the  second bank. This second update is required for the ATCA‐43xx because the redundant 

BIOS feature requires both BIOS banks to be at the same version.

Updating non-redundant devices

Run the rsys‐update utility again and specify the  ‐‐non‐redundant  option to update any non‐ redundant devices. Examples include:

• Board IPMC FRU data (ATCA‐4300, ATCA‐4310, ATCA‐4500, ATCA‐4550, ATCA‐4555, ATCA‐

1200, ATCA‐2210, ATCA‐7220, ATCA‐9100)

• ATCA‐7220 DPB FPGA and software

• AMC‐7211 and AMC‐7212 boot flash

See 

Table 1   on page 10

 for a full listing of redundant and non‐redundant devices for each  product.

To update a module’s non‐redundant devices:

1. Use the  dry‐run  option of rsys‐update. This command displays a simulation of the update  procedure and identifies the targeted non‐redundant devices.  rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐dry‐run ‐‐automatic  ‐‐non‐ redundant

2. Update the non‐redundant devices: rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic ‐‐non‐redundant

For example, the following command updates the device using the factory recommended  order and outputs a log file if any errors occur: rsys‐update ‐‐path /tmp/rsys‐update/ATCA‐4300‐2.3.13‐2‐rh‐firmware/  ‐‐ automatic ‐‐non‐redundant ‐‐log‐file logfile

3. After the reboot, enter this command to confirm the new version: rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐versions ‐‐non‐redundant

35

Using rsys-update for single product updates 3

Updating the ATCA-7220 DPB BSPs from 1.4.x to 1.5.x

To update the ATCA‐7220 DPB from 1.4.x to 1.5.x (SDK 1.7.2 to 1.9), different update  procedures are used if the DPB is booted to Linux or to U‐Boot.

Booted to Linux

If the ATCA‐7220 DPB is booted to Linux, the DPB BSP can be updated using the following  command: rsys‐update ‐‐path ATCA‐7220‐1.12.14.1.4_SDK1.9_Octeon1.5‐1‐firmware.tgz  ‐‐ automatic ‐‐non‐redundant

Booted to U-Boot

The DPB BSP flash mapping is modified for the 1.5.x update, so the  ‐‐automatic ‐‐non‐ redundant  options cannot complete the update if the DPB is booted to U‐Boot. Instead,  execute the following command to update all flash memory from 1.4.x to 1.5.x and ignore the  flash map check: rsys‐update ‐‐path ATCA‐7220‐1.12.14.1.4_SDK1.9_Octeon1.5‐1‐firmware.tgz  ‐‐

DPB‐os:update ‐‐override ‐‐all

36

Chapter

4

Updating ATCA-45xx CPMs

This chapter describes the installation of RPM packages and the BIOS driver for updating 

ATCA‐4500, ATCA‐4550, ATCA‐4555, and ATCA‐4580 CPMs.

These are the operating systems supported by the ATCA‐4500, ATCA‐4550, and ATCA‐4555 

CPMs:

• Monta Vista 4, 32‐bit (Monta Vista CGE 4.0 i386)

• Monta Vista 5, 64‐bit (Monta Vista CGE 5.0 x86‐64)

• Red Hat 5, 64‐bit (Red Hat 5.4 x86_64)

• Wind River 2, 32‐bit (Wind River PNE‐LE 2.0 i686)

• Wind River 2, 64‐bit (Wind River PNE‐LE 2.0 x86_64)

These are the operating systems supported by the ATCA‐4580 CPM:

• Red Hat 5.4, 64‐bit

• Wind River 3.0, 64‐bit

Each operating system has its own set of RPM packages that need to be installed to support  automated updates using rfw‐update and rsys‐update, or manual board‐level updates using  the individual update tools. For board‐level component updates, the update procedure notes  which RPM packages are required for that update.

Contact Radisys Support if additional assistance is needed for installing the required RPM  packages for specific operating systems.

Installing the required OS RPM packages

Before running the update, you need to prepare the CPM by installing the latest OS RPMs. 

Locate the RPMs by decompressing the ATCA‐4500‐<version>.tgz, ATCA‐4550‐<version>.tgz,  or ATCA‐4555‐<version>.tgz file for your specific OS. The file is located in the ATCA‐4500, 

ATCA‐4550, or ATCA‐4555 directory on the software release image. The RPMs are in the RPMS  folder within the packages folder.

Table 3   on page 38  lists the Radisys RPM packages for the CPM, and provides a brief functional  description of their contents. The Required for the update process column indicates which 

RPM packages should be installed to support both automated and manual update methods.

Note: Depending on your OS type or version, some of the RPMs listed are not supplied.

37

Updating ATCA-45xx CPMs 4

See the Promentum Software Guide for more information about RPM packages.

RPM package name

AMC7212.RH.4500-<version>.rpm

amifldrv-<version>.rpm

amifldrv-core8-<version>.rpm

bioscli2-<version>.rpm

biosver-<version>.rpm

cpm_ioport_module-link-

<version>.rpm

cpm-release-<version>.rpm

cpm-utils-<version>.rpm

fruinfo-<version>.rpm

fru-update-<version>.rpm

garp-<version>.rpm

igb-<version>.rpm

ispVMEmbedded-<version>.rpm

ixgbe-<version>.rpm

libhcl-<version>.rpm

libhcl-devel-<version>.rpm

libmpf-<version>.rpm

libmpf-devel-<version>.rpm

libmpf-link-<version>.rpm

libsml-<version>.rpm

libsml-devel-<version>.rpm

Table 3. RPM packages provided with the CPM update bundle cpm_ioport_module-<version>.rpm

No

No

No

No

No

No

No

Required for the update process

No

Yes

Yes

No

Yes

Yes

Yes

No

No

Yes

Yes

No

No

Yes

No

Functional description

Provides libraries, utilities, and PCIe drivers for the AMC-7212 on the

ATCA-4500, ATCA-4550, and ATCA-4555.

Note: This RPM is only required for Red Hat 5, 64-bit.

A kernel driver module that is required for updating the BIOS for the

ATCA-4500, ATCA-4550, and ATCA-4555.

A kernel driver module required to update the ATCA-4580 BIOS.

A command-line interface for manipulating EFI BIOS options in Linux.

A tool that displays the BIOS version and BIOS image file version number for the module.

A kernel module that creates character devices so applications can program the CPU Complex FPGA.

Re-linkable kernel binary modules for cpm_ioport_module-

<version>.rpm.

Release information documents installed in the usr/share/doc folder.

Default and example Ethernet bonding, interface configuration, and dhclient templates used with make-interfaces. This tool also provides an example udev rule for assigning disk names based in Fibre Channel

WWPN, a script to set the command prompt based on module geographic information such as slot and chassis, a script to disable the watchdog, and a script to copy the fruinfo log to syslog.

A script that retrieves FRU and shelf configuration information (IPMB address, slot number, etc.).

Updates the FRU data while preserving module-specific FRU data.

A tool that sends Gratuitous Attribute Registration Protocols (GARP) to check for unused IP addresses and automatically assign them from a given IP range.

Linux kernel driver for the Intel Gigabit family of server adapters.

Lattice ported version of ispVM to program the CPU Complex FPGA.

Linux kernel driver for the Intel 10GbE PCI Express family of server adapters.

HCL library and Radisys HPI demos HCL library and software.

Header and object files for developing programs that use libhcl.

This library provides functions for error logging, runtime debug logging, and syslog. It also provides an application event loop for timers, socket connections, and hardware interrupts. The libmpf library is required by

Radisys CLI and SNMP packages.

Libraries and header files for developing applications that use libmpf.

Libraries and header files for binary linking of applications using libmpf.

Contains the SML API.

Contains the header and object files necessary for developing programs which use libsml.

38

Updating ATCA-45xx CPMs 4

Table 3. RPM packages provided with the CPM update bundle (continued)

RPM package name make-interfaces-<version>.rpm

mcli-<version>.rpm

mcli-devel-<version>.rpm

perl-Expect-<version>.rpm

perl-Inline-<version>.rpm

perl-IO-Tty-<version>.rpm

perl-Net-Telnet-<version>.rpm

perl-YAML-<version>.rpm

platform-mgmt-<version>.rpm

rfw-update-<version>.rpm

rsys_cpm_kernel-<version>.rpm

rsys_cpm_kernel-bsp-<version>.rpm

rsys_cpm_kernel-devel-<version>.rpm No rsysbflash-<version>.rpm

rsysbflash-core8-<version>.rpm

rsys-eeupdate-<version>.rpm

rsys-eswapi2-<version>.rpm

rsys-eswapi2-devel-<version>.rpm

rsys-ethtool-<version>.rpm

rsys-ipmitool-<version>.rpm

rsys-python-yaml-<version>.rpm

Required for the update process

No

Functional description

No

No

Yes

Yes

Yes

Yes

Yes

No

Yes

Yes

No

Yes

Yes

Yes

No

No

Yes

Yes

No

A script that creates network dhclient and interface files from their templates, substituting FRU information for chassis and physical slot.

A tool that supplies the master command-line interface for the CPM.

A tool that provides the header files necessary for developing programs that use the mcli.

A Perl module that provides Expect-like functionality to Perl. Expect is a tool for automating interactive applications like telnet, ftp, passwd, fsck, rlogin, and tip. Required by the rfw-update utility for scripting.

A Perl module that provides the ability to put source code from another programming language directly inline in a Perl script or module.

Required by the rfw-update utility for scripting.

A Perl module that supplies pseudo ttys and constants for Perl scripts.

Required by the rfw-update utility for scripting.

A Perl module that makes client connections to a TCP port and performs network I/O, particularly to a port using the TELNET protocol.

Required by the rfw-update utility for scripting

A Perl module that implements a YAML loader and dumper based on the YAML specification. Required by the rfw-update utility for scripting.

A tool that enables platform management CLI operations.

A tool that performs firmware updates on multiple remote Radisys modules.

A tool that provides the Linux operating system kernel for the CPM.

Note: This RPM is only required for Wind River 2, 64-bit for the ATCA-

4500, ATCA-4550, and ATCA-4555. This RPM is also required for Wind

River 3, 64-bit for the ATCA-4580.

This kernel RPM must be built from rsys_cpm_kernel-

<version>.src.rpm located in the Wind River SRPMS directory.

A tool that provides a Radisys BSP board template directory for use with the Wind River Developer Kit and Workbench.

A tool that provides kernel headers and makefiles for building modules to match the kernel package.

A BIOS update utility for the ATCA-4500, ATCA-4550, and ATCA-4555

CPM.

A BIOS update utility for the ATCA-4580 CPM.

A tool that reads and writes to the EEPROM of an Ethernet device.

Provides the Radisys Ethernet switching API.

Provides the development files for rsys-eswapi2.

A tool to get and set values to the module Ethernet controllers.

A tool that provides commands for reading the Sensor Data Repository

(SDR) and displaying sensor values, displaying the contents of the

System Event Log (SEL), printing FRU information, and reading and setting LAN configuration and shelf power control.

Provides Radisys YAML for python.

39

Updating ATCA-45xx CPMs 4

Table 3. RPM packages provided with the CPM update bundle (continued)

RPM package name rsys-rpc-support-<version>.rpm

rsys-rpc-support-devel-<version>.rpm No rsys-rpc-tools-<version>.rpm

rsys-update-<version>.rpm

shmgr-<version>.rpm

shmgr-devel-<version>.rpm

yaml-<version>.rpm

yaml-devel-<version>.rpm

Required for the update process

No

Functional description

No

Yes

No

No

Yes

Yes

Provides RPC-based Ethernet API functions for configuring the

Ethernet switch on ATCA products.

Provides the libraries and header files for developing applications that use rsys-rpc-support.

Provides a set of Radisys RPC code generator tools.

A tool that updates the firmware components on a module.

A tool that provides the Shelf Manager application. The application runs in a “blade” mode on the CPM with just the HPI server portion enabled to create and manage the Firmware Update Management Instrument

(FUMI) through which updates can be done.

A tool that supplies the header and object files for developing HPI server FUMI applications.

A tool that provides a framework for low-level network monitoring.

A tool that provides the header and object files necessary for developing programs that use YAML.

Follow these steps to install and update the required RPM packages:

1. Verify the OpenIPMI driver is loaded for your OS. The driver must be running to complete  the upgrade. 

This command loads the IPMI driver with IRQ6 as the KCS interface interrupt: modprobe ipmi_si.o irqs=irq6

For Red Hat, use this command:

/etc/init.d/ipmi start

2. Locate the ATCA‐45xx‐<version>.tgz file appropriate for the ATCA‐4500, ATCA‐4550, ATCA‐

4555, or ATCA‐4580 in the Promentum software image. Copy the ATCA‐45xx‐<version>.tgz  file to a temporary directory on the CPM. Choose a path and name that can be easily  accessed for the remaining steps.

3. Decompress the ATCA‐45xx‐<version>.tgz file by entering the following command from  within the temporary directory: tar ‐xzvf <version>.tgz

This creates a directory named <version> in the temporary directory. The RPMs for each  supported OS are located under the packages directory. For example, the packages for 

MontaVista CGE 4.0 for the ATCA‐4500 can be found in this directory: packages/Radisys/releases/2.3/montavista/4/x86_pentium4/ATCA‐4500/RPMS/

4. Install or update all required RPMs by entering the following command for each package: rpm ‐Uhv <path_to_packages>/<rpm package>.rpm ‐‐replacepkgs

40

Updating ATCA-45xx CPMs 4

Installing the BIOS update driver for rsys-update

Note: These installation instructions for the BIOS update driver only apply to the ATCA‐4500, 

ATCA‐4550, and ATCA‐4555 CPMs.

Before running the BIOS update, the rsysbflash utility and the proper kernel driver module for  the BIOS flash must be installed. The Promentum software release contains the standard  kernel driver for the specific operating system. The utility and driver are installed when you  install the RPMs listed in Table 1 on page 2 that are required for the update process.

After all required RPM packages are installed, the kernel module installation can be verified by  running this command to list the kernel driver contents: ls /lib/modules/‘uname ‐r‘/extra/amifldrv/

If driver file amifldrv_mod.o is listed, proceed to 

Verifying the BIOS driver on page 42 .

Building the flash update driver

If an appropriate amifldrv.rpm package is not in the software release due to the type of kernel  in use on the CPM, the flash update driver must be built using the rsysbflash utility. Follow  these steps to build and install the flash update driver:

1. From the Promentum software release, install biosver.rpm and the rsysbflash RPM  package for your operating system. This step does not need to be done if the required 

RPMs listed in  Table 3   on page 38  are already installed. 

2. If the CPM uses a cross‐compiled version of Wind River 2.0, specify the ARCH and 

CROSS_COMPILE environment variables before running the  rsysbflash

 command in step 3. 

The same settings are used that are used to cross‐compile the kernel. See the Wind River  documentation for details about the environment variables and compiling the kernel.

3. Run rsysbflash, passing it the arguments to build the driver.

rsysbflash /MAKEDRV

The utility produces the driver file amifldrv_mod.o in the directory where rsysbflash is  executed. If the driver is built successfully, a message similar to the following is generated  by rsysbflash:

+‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐+

| AMI Firmware Update Utility(APTIO) v2.27                        |

| Copyright (C)2009 American Megatrends Inc. All Rights Reserved. |

+‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐+

   ‐ Program initializing..

   ‐ Make AFULNX driver.... ok

   ‐ Program ended normally.

4. Create the 

/lib/modules/ ‘ uname ‐r ‘ /extra/amifldrv/

 directory if it does not exist.

mkdir ‐p /lib/modules/‘uname ‐r‘/extra/amifldrv/

5. Copy the driver file amifldrv_mod.o to 

/lib/modules/ ‘ uname ‐r ‘ /extra/amifldrv/

. This  enables rsys‐update to work with the new driver.

41

Updating ATCA-45xx CPMs

Verifying the BIOS driver

Before running rsys‐update, verify the BIOS driver is present by entering this command: rsys‐update ‐‐path /<path><update‐bundle> ‐‐versions

The  ‐‐versions  option shows the version for all active, standby, and update bundle 

components. See  rsys‐update command options on page 32  for details.

4

42

Chapter

5

Setting the CPM boot block jumpers

The boot block for ATCA‐4300, ATCA‐4310, ATCA‐4500, ATCA‐4550, and ATCA‐4555 CPMs is  typically write‐protected to prevent accidental overwrites. Depending on the CPM, a jumper  needs to be installed or removed from specific header pins to enable updates to the boot  block.

ATCA-4300 and ATCA-4310 CPM

To update the ATCA‐4300 or ATCA‐4310 boot block, install a jumper to enable writes to the 

FWH boot block. 

Note: The CPMs have the jumper pre‐installed starting from the following boards:

• A4300‐CPU‐SAS‐FE 067‐07796‐0010

• A4300‐CPU‐CFG01 067‐09420‐0007

Refer to  Figure 3  and  Figure 4  for locations of the headers where the jumpers are installed.

Figure 3. ATCA-4300 boot block header location

Install boot block jumper on pins 2-3

43

Setting the CPM boot block jumpers

Figure 4. ATCA-4310 boot block header location

5

Install boot block jumper here (P6)

ATCA-4500, ATCA-4550, and ATCA-4555 CPM

To update the boot block for the ATCA‐4500, ATCA‐4550, and ATCA‐4555 CPM, power down 

the module, and remove the jumper on pins 1 and 2 of header J1. See  Figure 5 on page 45 .

44

Setting the CPM boot block jumpers

Figure 5. ATCA-4500, ATCA-4550, and ATCA-4555 boot block header location

5

Remove the jumper on pins 1 and 2 of J1

45

Chapter

Board-level updates for the ATCA-45xx CPM and RTM

6

The ATCA‐4500, ATCA‐4550, ATCA‐4555, and ATCA‐4580 CPMs and their RTMs must be  manually updated at the board level, if a custom operating system is used or if the CPM and 

RTM are installed in a non‐Promentum shelf.

These are the CPM and RTM board‐level update procedures:

Updating the BIOS on page 46

Updating the IPMI firmware and FPGA for ATCA‐4500, ATCA‐4550, and ATCA‐4555 on  page 48

Updating the IPMI firmware for ATCA‐4580 on page 50

Updating the CPM FRU on page 53

Updating the EEPROM for ATCA‐4500, ATCA‐4550, ATCA‐4555 on page 54

Updating the EEPROM for ATCA‐4580 on page 56

Updating the SAS firmware for ATCA‐4580 on page 57

Updating the legacy FPGA and SPI flash for ATCA‐4500, ATCA‐4550, and ATCA‐4555 on  page 58

Updating the RTM MMC firmware, FRU, and alarm CPLD on page 60

Updating the RTM SAS firmware on page 65

Downgrading a CPM to an earlier firmware version on page 66

Updating the BIOS

These instructions describe CPM BIOS flash update methods that are executed from the Linux  command line or from the EFI shell.

For ATCA-4500, ATCA-4550, and ATCA-4555

Updating the BIOS from the Linux command line

The rsysbflash utility is used to update the BIOS from the Linux command line. The utility and  its kernel driver must be installed before the BIOS update can be performed.

1. Install the rsysbflash RPM and the kernel driver. See  Installing the BIOS update driver for 

rsys‐update on page 41  for details. 

2. Copy the BIOS.ROM file from the firmware/bios folder for the OS update bundle to a  location that is accessible to the rsysbflash utility.

3. Run rsysbflash to update the BIOS and retain the current BIOS settings: rsysbflash BIOS.ROM /p /b /x

46

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating the BIOS from DOS

1. Copy AFUEFIx64.efi, BIOS.rom, and update.nsh to a USB flash drive and boot into the EFI  shell. The files are located in the firmware/bios folder for the OS update bundle.

2. Switch to the file system on the USB flash drive (usually fs0:).

fs0:

3. Run the update.nsh batch file to update one bank.

rsysbflash BIOS.ROM /p /b /x

4. Reboot the CPM to the updated bank.

5. Run the batch file again to update the remaining bank.

6. Enter the BIOS configuration and verify that both banks have the proper BIOS version.

For ATCA-4580

Updating the main BIOS from the Linux command line

The rsysbflash‐core8 utility is used to update the BIOS from the Linux command line. The  utility and its kernel driver must be installed before the BIOS update can be performed. 

1. Install the rsysbflash‐core8 RPM and the kernel driver. 

2. Copy the  <filename>.ROM file  ( A4580008.ROM

) from the  firmware/bios  folder for the OS  update bundle to a location that is accessible to the rsysbflash‐core8 utility.

3. Run rsysbflash‐core8 from the Linux command line to update the main BIOS: rsysbflash‐core8 <filename>.ROM /P /B /N /X /C

Updating both BIOS banks from the Linux command line

Perform the following steps to use the rsysbflash‐core8 utility to update both BIOS banks from  the Linux command line.

1. Install the rsysbflash‐core8 RPM and the kernel driver. 

2. Copy the  <filename>.ROM

 file ( A4580008.ROM

) from the  firmware/bios  folder for the OS  update bundle to a location that is accessible to the rsysbflash‐core8 utility.

3. Switch to bank 2:

# rsys‐ipmitool raw 0x30 0xFA 0x02

4. Run the update:

# rsysbflash‐core8 <filename>.ROM /P /B /N /X /C

5. Switch back to bank 1:

# rsys‐ipmitool raw 0x30 0xFA 0x01

6. Run the update:

# rsysbflash‐core8 <filename>.ROM /P /B /N /X /C

47

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating the IPMI firmware and FPGA for ATCA-4500, ATCA-4550, and

ATCA-4555

These firmware upgrade instructions comply with the PICMG HPM.1 specification. The IPMI  controller and associated circuitry include a number of upgradable components. Some of  these components are upgraded individually, while others are upgraded as a group.

You can upgrade the IPMI firmware and FPGA using either the KCS interface or the LAN  interface. For further details, refer to the specific shelf or carrier documentation.

Preparing rsys-ipmitool

Before using rsys‐ipmitool, verify that the version is Radisys build 2.15 or newer by running  rsys‐ipmitool ‐V . Additionally, if you have copied the rsys‐ipmitool file using a Windows  system, you must make the file an executable. Enter these commands at the Linux prompt: chmod +x rsys‐ipmitool

./rsys‐ipmitool ‐V

Updating from the KCS interface

When rsys‐ipmitool is run from the payload processor (Linux OS), it uses the local KCS payload  interface.

1. Verify that communication is possible to the IPMC:

./rsys‐ipmitool mc info

2. If the previous command is successful, continue to step 3. Otherwise, check that the IPMI  drivers are successfully installed and retry the command.

rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐versions

3. Copy the hpm image file into the OS file system. The example hpm file for this procedure  is for the ATCA‐4500.

4. Check the firmware image versions running on the CPM and contained in the hpm file:

./rsys‐ipmitool hpm check cpm7_all.hpm

The command identifies the active, backup, and file versions, providing a snapshot of  upgradable components.

5. Upgrade and activate the CPM:

./rsys‐ipmitool hpm upgrade cpm7_all.hpm activate

If the command fails, retry it three times before calling Support for assistance.

All components on the target (boot, application, and FPGA) that do not match the version  provided in the hpm file are upgraded.

6. After the upgrade is complete, upgrade and activate the application component again. 

This is necessary because the application component has a backup copy.

./rsys‐ipmitool hpm upgrade cpm7_all.hpm component 1 activate

48

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating from the LAN (Shelf Manager)

Record the IP address of the active Shelf Manager and the IPMB address of the CPM to be  upgraded. For the example commands in this procedure, the IP address is 10.100.18.20 and  the target module is in slot 10 (IPMB address 0x8C). This information can be obtained by  running the fruinfo tool provided in the update bundle package.

1. Verify that LAN connectivity to the Shelf Manager IP address is established:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none mc info

If the command is successful then continue to the next step. If the command fails, contact  your system administrator to re‐establish the LAN interface for the Shelf Manager.

Note: Some shelf manager RMCP servers require levels of authentication, including a  username and password. See the rsys‐ipmitool man page for other required options.

2. Make sure the target CPM exists and is communicating:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c mc info

If the command fails, the CPM cannot be upgraded in its current state. Extract and reinsert  the CPM, then retry the command. If it still fails, contact Support for assistance.

3. Verify if the firmware was updated to the latest version. This command identifies the  active, backup, and file versions:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm check cpm7_all.hpm

4. Start the upgrade with this command:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm upgrade cpm7_all.hpm  activate

The following prompt appears:

Services may be affected during upgrade. Do you wish to continue? y/n

Enter  y  to continue. The upgrade takes several minutes. All components are upgraded on  the CPM (boot, application, and FPGA) that do not match the versions in the hpm file.

W ARNING :   Do not interrupt the upgrade once you start it. If problems occur, do not power off  the module before contacting Support.

If the command fails, retry it three times before contacting Support for assistance.

Components are skipped if the tool determines they are already up to date. This is especially  important for the bootloader. If the firmware is reset or loses power while updating the  bootloader, the firmware needs to be reprogrammed over JTAG.

5. After the upgrade is complete, upgrade and activate the application component again. 

This command updates the backup copy:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm upgrade cpm7_all.hpm  component 1 activate

6. Enter  y  to continue when the following prompt appears:

Services may be affected during upgrade. Do you wish to continue? y/n

7. Enter this command to verify that the new firmware versions are being used:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm check cpm7_all.hpm

49

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating the IPMI firmware for ATCA-4580

These ATCA‐4580 firmware upgrade instructions comply with the PICMG HPM.1 specification  from PICMG. The IPMI controller and associated circuitry include a number of upgradeable  components. Some of these components are upgraded individually, while others are  upgraded as a group.

You can upgrade the IPMI firmware using either the KCS interface or the LAN interface. For  further details, refer to the specific shelf or carrier documentation.

Preparing rsys-ipmitool

Before using rsys‐ipmitool, verify that the version is Radisys build 2.15 or newer by running  rsys‐ipmitool ‐V . Additionally, if you have copied the rsys‐ipmitool file using a Windows  system, you must make the file an executable. Enter these commands at the Linux prompt: chmod +x rsys‐ipmitool

./rsys‐ipmitool ‐V

Updating from the KCS interface

When rsys‐ipmitool is run from the payload processor (Linux OS), it uses the local KCS payload  interface.

1. Verify that communication is possible to the IPMC.

./rsys‐ipmitool mc info

2. If the previous command is successful, continue to step 3. Otherwise, check that the IPMI  drivers are successfully installed and retry the command.

3. Copy the .img image file into the OS file system.

4. Check the firmware image versions running on the CPM and contained in the img file:

./rsys‐ipmitool hpm check hpm1fw_<version>.img

This command identifies the active, backup, and file versions, providing a snapshot of  upgradeable components.

5. Upgrade and activate the CPM:

./rsys‐ipmitool hpm upgrade hpm1fw_<version>.img activate

If the command fails, retry it three times before calling Support for assistance. All  components on the target (boot loader and firmware) that do not match the version  provided in the img file are upgraded.

6. After the upgrade is complete, upgrade and activate the firmware ( H8S‐AMCc F/ )  component again. This is necessary because the firmware component has a backup copy.

./rsys‐ipmitool hpm upgrade hpm1fw_<version>.img component 0 activate

50

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating from the LAN (Shelf Manager)

Record the IP address of the active Shelf Manager and the IPMB address of the ATCA module 

to be upgraded. See  Appendix B, IPMB and IPMB‐L address mapping, on page 85  to determine 

the IPMB address. For further details, refer to the specific shelf or carrier documentation. For  the example commands in this procedure, the IP address is 10.100.18.20 and the target  module is in slot 10 (IPMB address 0x8C). This information can be obtained by running the  fruinfo  tool provided in the update bundle package.

1. Verify that LAN connectivity to the Shelf Manager IP address is established:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none mc info

If the command is successful then continue to the next step. If the command fails, contact  your system administrator to re‐establish the LAN interface for the Shelf Manager.

Note: Some shelf manager RMCP servers require levels of authentication, including a  username and password. See the rsys‐ipmitool man page for other required options.

2. Make sure the target ATCA module exists and is communicating:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c mc info

If the command fails, the module cannot be upgraded in its current state. Extract and  reinsert the target module, then retry the command. If it still fails, contact Support for  assistance.

3. Verify if the firmware was updated to the latest version:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm check  hpm1fw_<version>.img

This identifies the active, backup, and file versions. It is a snapshot of upgradeable  components.

4. Start the upgrade with this command:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm upgrade  hpm1fw_<version>.img activate

The following prompt appears:

Services may be affected during upgrade. Do you wish to continue? y/n

5. Enter  y  to continue. The upgrade takes several minutes. All components are upgraded on  the target (boot loader and firmware) that do not match the version provided in the img  file.

WARNING! 

• Do not interrupt the upgrade once you start it.

• If problems occur, do not power off the module before contacting Support.

• If the command fails, retry it at least two more times before contacting Support for  assistance.

51

Board-level updates for the ATCA-45xx CPM and RTM 6

6. The output should be similar to the following:

#  rsys‐ipmitool hpm upgrade hpm1fw_<version>.img activate

PICMG HPM.1 Upgrade Agent 1.0:

Validating firmware image integrity...OK

Performing preparation stage...

Services may be affected during upgrade. Do you wish to continue? y/n y

OK

Performing upgrade stage:

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐

|ID | Name      |            Versions            |    Upload Progress  |Upload|

|   |           | Active   | Backup   | File     |0%       50%     100%|Time  |

|‐‐‐|‐‐‐‐‐‐‐‐‐‐‐|‐‐‐‐‐‐‐‐‐‐|‐‐‐‐‐‐‐‐‐‐|‐‐‐‐‐‐‐‐‐‐||‐‐‐‐+‐‐‐‐+‐‐‐‐+‐‐‐‐||‐‐‐‐‐‐|

|*0 |H8S‐AMCc F/|  1.31.00 |  1.0f.00 |  1.31.00 ||...................|| 2.31 |

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐

(*) Component requires Payload Cold Reset

Performing activation stage:

Firmware upgrade procedure successful

Components are skipped if the tool determines they are already up‐to‐date. This is  especially important for the boot loader. If the firmware is reset or loses power while  updating the boot loader, the firmware needs to be reprogrammed over JTAG.

7. After the upgrade is complete, upgrade and activate the firmware component again. This  command updates the backup copy:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm upgrade hpm1fw_<version>.img component 0 activate

Enter y to continue when the following prompt appears:

Services may be affected during upgrade. Do you wish to continue? y/n

8. Enter this command to verify that the new firmware versions are being used:

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none ‐t 0x8c hpm check  hpm1fw_<version>.img

52

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating the CPM FRU

1. From a module or head system with access to the Shelf Manager, verify that these files  from the Promentum software release are present:

• FRU .bin and .cfg files

fru_update utility

frutool utility

rsys‐ipmitool utility

./rsys‐ipmitool ‐I lan ‐H 10.100.18.20 ‐A none mc info

2. Run the fru_update command using the following format:

For ATCA‐4500, ATCA‐4550, ATCA‐4555 fru_update "‐I lan ‐H <shelf IP address> ‐A none ‐t <blade IPMB address>"     cpm7_rs_frud_01_01.cfg cpm7_rs_frud_01_01.bin

For ATCA‐4580 fru_update "‐I lan ‐H <shelf IP address> ‐A none ‐t <blade IPMB address>"  atca4580_rs_frud_<version>.cfg fru‐info.bin

Note: Some Shelf Manager RMCP servers require levels of authentication, including a  username and password. The parameters in the quoted string are passed directly to rsys‐

ipmitool and may need to be modified accordingly. See the rsys‐ipmitool man page for any  additional options.

53

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating the EEPROM for ATCA-4500, ATCA-4550, ATCA-4555

This procedure updates the entire EEPROM for the ATCA‐4500, ATCA‐4550, and ATCA‐4555 

CPM, except for the MAC address.

Determine the NIC number

The NIC (Network Interface Card) numbers for the Base, Fabric, and Front Ethernet controllers  need to be determined so they can be used during the EEPROM update. To identify the NIC  numbers, execute the following command: rsys‐eeupdate list

An example of the command output is shown below. The first column lists the NIC number,  and the second, third, and fourth columns list the associated PCI bus number.

NIC Bus Dev Fun Vendor‐Device

5

6

3

4

1

2

3

3

0

0

14 0

14 0

35 0

35 0

0

1

0

1

0

1

8086‐10C9

8086‐10C9

8086‐10B6

8086‐10B6

8086‐10C9

8086‐10C9

Branding String

Intel(R) 82576 Gigabit Dual Port Network Connection

Intel(R) 82576 Gigabit Dual Port Network Connection

Intel(R) 82598EB 10 Gigabit KX4 Network Connection

Intel(R) 82598EB 10 Gigabit KX4 Network Connection

Intel(R) 82576 Gigabit Dual Port Network Connection

Intel(R) 82576 Gigabit Dual Port Network Connection

Table 4  matches up the Ethernet controllers with their PCI bus numbers and corresponding  update files:

Table 4. Ethernet controller selection

Controller

Base

Fabric

Front

Bus

3

14

35

PCI bus number

Dev

0

Fun

Image file

0 or 1 BASE_X.eep

0

0

0 or 1

0 or 1

OPLIN_X.eep

FRONT_X.eep

Note: The PCI bus number may change with a newer BIOS release. The PCI bus number to 

BIOS version mapping needs to be maintained. 

Using the NIC numbers from the previous example output, the Fabric, Base, and Front 

Ethernet controllers can be programmed using these commands:

Fabric rsys‐eeupdate install i 3 s OPLIN_6.eep

Base rsys‐eeupdate install i 1 s BASE_3.eep

Front rsys‐eeupdate install i 5 s FRONT_3.eep

54

Board-level updates for the ATCA-45xx CPM and RTM 6

Perform the update

1. After booting the CPM, verify that rsys‐eeupdate.rpm is installed as part of the required 

packages listed in  Table 3   on page 38

. The rsys‐eeupdate binary is installed in the /usr/sbin  directory.

2. Copy all eep files to the CPM running Linux. The eep files are located on the Promentum  software release in the firmware/ethernet folder for your operating system update  bundle.

3. Flash the Front Ethernet controller: rsys‐eeupdate install i X s FRONT_3.eep

Replace  X  with the NIC number for the Front eth controller.

4. Flash the Base Ethernet controller: rsys‐eeupdate install i X s BASE_3.eep

Replace  X  with the NIC number for the Base eth controller.

5. Flash the Fabric Ethernet controller: rsys‐eeupdate install i X s OPLIN_6.eep

Replace  X  with the NIC number for the Fabric eth controller.

Warning! Each controller supports two interfaces. The rsys‐eeupdate tool should be run  on only one eth interface. It will update both interfaces at the same time.

6. Reboot the Linux OS to make the change effective.

Verify the EEPROM version

To verify the correct EEPROM version, use rsys‐eeupdate to read the version field from the 

EEPROM. Execute the following command: rsys‐eeupdate i X oemver

Replace  X  with the correct NIC number.

The following command example reports that the Base EEPROM is version 3.

rsys‐eeupdate i 1 oemver

Output of rsys‐eeupdate:

EEPROM OEM Revision: 0x0003

55

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating the EEPROM for ATCA-4580

This procedure updates the ATCA‐4580 EEPROMs except for the MAC address. The  rsys‐ eeupdate  utility is used to update an Ethernet EEPROM from the Linux command line. The  utility and its kernel driver must be installed before the EEPROM update can be performed.

Table 5  provides device information for the ATCA‐4580 Ethernet controllers.

Table 5. ATCA-4580 Ethernet Device Information

Ethernet Controller

Intel 82576 (RTM)

Intel 82576 (Base)

Intel 82599 (Fabric)

PCI Bus, Device, Function Numbers .EEP Update File Location

Bus 04, Device 00, Functions 00,01 ATCA-4580-

<version>/usr/share/firmware/Radisys/system_mfr_0x

10f1_prod_0x1715/pci_firmware_pcibus_04.00.00_82

576RTM/

Bus 08, Device 00, Functions 00,01

Bus 09, Device 00, Functions 00,01

ATCA-4580-

<version>/usr/share/firmware/Radisys/system_mfr_0x

10f1_prod_0x1715/pci_firmware_pcibus_08.00.00_82

576BASE/

ATCA-4580-

<version>/usr/share/firmware/Radisys/system_mfr_0x

10f1_prod_0x1715/pci_firmware_pcibus_09.00.00_82

599FABRIC/

Intel 82576 (front panel) Bus 11, Device 00, Functions 00,01 ATCA-4580-

<version>/usr/share/firmware/Radisys/system_mfr_0x

10f1_prod_0x1715/pci_firmware_pcibus_11.00.00_82

576FRONT/

Perform the following steps to update the Ethernet EEPROM:

1. Install the rsys‐eeupdate RPM and the kernel driver.

2. Using rsys‐eeupdate, determine the NIC, PCI Bus, Device, and Function numbers of the 

Ethernet EEPROM that is to be upgraded:

#  ./rsys‐eeupdate l

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐

NIC Bus Dev Fun Vendor‐Device Branding String

==================================================================================

1   4   0   0    8086‐10E7  Intel(R) 82576 Gigabit Dual Port Server ExpressModule

2   4   0   1    8086‐10E7  Intel(R) 82576 Gigabit Dual Port Server ExpressModule

3   8   0   0    8086‐10C9  Intel(R) 82576 Gigabit Dual Port Network Connection

4   8   0   1    8086‐10C9  Intel(R) 82576 Gigabit Dual Port Network Connection

5   9   0   0    8086‐10F8  Intel(R) 82599 10 Gigabit Dual Port Backplane Connection

6   9   0   1    8086‐10F8  Intel(R) 82599 10 Gigabit Dual Port Backplane Connection

7   11  0 0

8   11  0  1

8086‐10C9  Intel(R) 82576 Gigabit Dual Port Network Connection

8086‐10C9  Intel(R) 82576 Gigabit Dual Port Network Connection

3. Using the PCI Bus, Device, and Function number in  Table 5 , locate the correct .eep file  associated with Ethernet device's EEPROM to be upgraded in the CPM update bundle.

56

Board-level updates for the ATCA-45xx CPM and RTM 6

4. Upgrade the appropriate EEPROM using  rsys‐eeupdate :

# ./rsys‐eeupdate install i <NIC Number> s <.eep source file>

Notes: 

• The  install  command does not update the existing MAC address(es) in the EEPROM

• Only one NIC on each device needs the update because the entire EEPROM gets  updated regardless of which NIC port gets the update

• Add the “ ni ” command‐line option for non‐interactive mode (runs install without  prompting user to continue)

Updating the SAS firmware for ATCA-4580

The sasflash utility updates the LSI SAS firmware for the ATCA‐4580 CPM. The sasflash utility  must be acquired from Radisys support for use with the Linux OS.

Follow these steps to update the LSI SAS on the CPM:

1. Contact Radisys Support to get the correct version of  sasFlashLinuxp16.zip

.

2. Decompress  sasFlashLinuxp16.zip

, maintaining the directory structure contained in the 

ZIP file.

3. The following application and files are necessary for the update in the Linux environment:

• sasflash  from the decompressed  sasflash_linux_i686_x86‐64_rel  directory

• YOUR_FW.FW

• mptsas.rom

Note: Files  YOUR_FW.FW

 and  mptsas.rom

 are located in the ATCA‐4580 CPM bundle on the 

Promentum software release media.

4. Boot the CPM to Linux.

5. Enter this command in Linux to update the SAS firmware and BIOS image: sasflash ‐o ‐f <FW file> ‐b <MPT BIOS file>

<FW file> is YOUR_FW.FW, and <MPT BIOS file> is mptsas.rom.

6. The following prompt may appear if an older version of the LSI firmware is being  upgraded:

Product ID and Vendor ID do not match. Would you like to flash anyway [y/n]?

Enter  y  to flash the firmware. The following message displays if the upgrade is successful:

Finished Processing Commands Successfully. Exiting SASFlash.

7. To verify the update, run this command to list information about the updated SAS  controller: sasflash ‐o ‐list

Compare the following example output with the information displayed on your adapter.

57

Board-level updates for the ATCA-45xx CPM and RTM 6

******************************************************************

LSI Corporation SAS FLASH Utility.

SASFlash Version 1.20.00.00 (2008.10.31)

Copyright (c) 2006‐2007 LSI Corporation. All rights reserved.

******************************************************************

Advanced Mode Set

Adapter Selected is a LSI SAS 1064E(B1):

Controller Number:               1

Controller:                      1064E(B1)

PCI Address:                     00:05:00:00

SAS Address:                     XXXXXXX‐X‐XXXX‐XXXX

NVDATA Version (Default):        0x2D07

NVDATA Version (Persistent):     0x2D07

Product ID:                      0x2704

Firmware Version:                01.27.00.00

NVDATA Vendor:                   LSILogic

NVDATA Product ID:               ATCA‐5400

BIOS Version:                    06.26.00.00

BIOS Alternate Version:          N/A

EFI BSD Version:                 N/A

FCODE Version:                   N/A

Finished Processing Commands Successfully.

Exiting SASFlash.

Updating the legacy FPGA and SPI flash for ATCA-4500, ATCA-4550, and

ATCA-4555

The legacy FPGA and legacy SPI flash can be programmed either from the running OS's  command line or externally using a programming cable. Currently, the command line utility is  the recommended way to program these components.

Update the legacy FPGA

The released software packages can be found on the Promentum software release. Browse  the latest release and find the tarball for the CPM (for example, ATCA‐4500/ATCA‐4500‐

2.3.24‐1.tgz). This tarball contains packages for all supported OS's.

These RPM packages are required to update the legacy FPGA, based on your OS:

Red Hat 5, 64‐bit

• ispVMEmbedded‐<version>.x86_64.rpm

• cpm_ioport_module‐<version>.el5.x86_64.rpm

MontaVista 4, 32‐bit

• ispVMEmbedded‐<version>.i686.rpm

MontaVista 5, 64‐bit

• ispVMEmbedded‐<version>.x86_em64t.rpm

58

Board-level updates for the ATCA-45xx CPM and RTM 6

Wind River 2, 32‐bit

• ispVMEmbedded‐<version>.i686.rpm

• cpm_ioport_module‐<version>_18cpm.i686.rpm

Wind River 2, 64‐bit

• ispVMEmbedded‐<version>.x86_64.rpm

• cpm_ioport_module‐<version>_hrt1_cfs_v22_grsec_rsys6.x86_64.rpm

Make sure the correct packages are used based on your OS and kernel variant.

The current legacy FPGA svf file (*.svf) is also needed. There are two svf files in the firmware  update legacyFpga folder: one for use with the RTM installed, and one for use without the 

RTM installed.

If the RTM is installed, use this file that has both the ComMux and the alarm CPLD bypassed: cpm7_legacy_commux_bypass_alarm_bypass_<version>.svf

If the RTM is not installed, use this file that only has the ComMux bypassed: cpm7_legacy_commux_bypass_<version>.svf

The following are example steps to program the legacy FPGA from a running RH5 64‐bit  system. Modify the file names in the commands according to your OS.

Note: These steps must be performed with root permissions.

1. Install or update the required software packages.

rpm ‐Uvh ispVMEmbedded‐1.2‐5.x86_64.rpm cpm_ioport_module‐1.05‐

1.2.6.18_164.el5.x86_64.rpm

2. Start the ioport service. This step can be skipped if you have rebooted or already started  the ioport service since installation of the above software packages

/etc/init.d/cpm_ioport_module start

3. Convert the svf file to vme. Note that the ISP tools require lower case extensions.

rsys‐svf2vme ‐infile <file>.svf ‐outfile <file>.vme

4. Program the FPGA.

Warning! Upon successful completion of the legacy FPGA update, the CPM will reboot  without shutting down the operating system. It is recommended that you mount the file  systems as read‐only prior to updating the FPGA to prevent any corruption.

rsys‐ispVME <file>.vme

5. Verify the version of the legacy FPGA: dd if=/dev/port bs=1 count=2 skip=1536 conv=swab 2>/dev/null | xxd dd if=/dev/port bs=1 count=1 skip=1582 2>/dev/null | xxd

The version output should be similar to the following, which reflects FPGA version 1.6:

0000000: 0001

0000000: 06

59

Board-level updates for the ATCA-45xx CPM and RTM 6

Update the legacy SPI flash (update only if the legacy FPGA is corrupted)

Note: Update the legacy SPI flash only if the legacy FPGA flash is corrupted during an update.

To update the legacy SPI flash, first see 

Update the legacy FPGA on page 58  for the two 

required packages based on your OS.

The current legacy SPI flash svf file (*.svf) is also needed. There are two svf files in the  firmware update legacyFpga folder: one for use with the RTM installed, and one for use  without the RTM.

If the RTM is installed, use this SPI flash file that has the ComMux and alarm CPLD bypassed: cpm7_legacy_spi_flash_commux_bypass_alarm_bypass_1_6.svf

If the RTM is not installed, use this file that only has the ComMux bypassed: cpm7_legacy_spi_flash_commux_bypass_1_6.svf

The following are example steps to program the legacy SPI flash from a running RH5 64‐bit  system. Modify the file names in the commands according to your OS.

Note: These steps must be performed with root permissions.

1. Install or update the required software packages if they were not already installed during 

Update the legacy FPGA on page 58

.

rpm ‐Uvh ispVMEmbedded‐1.2‐5.x86_64.rpm cpm_ioport_module‐1.05‐

1.2.6.18_164.el5.x86_64.rpm

2. Start the ioport service. This step can be skipped if you have rebooted or already started  the ioport service since installation of the above software packages.

/etc/init.d/cpm_ioport_module start

3. Convert the svf file to vme. Note that the ISP tools require lower case extensions.

rsys‐svf2vme ‐infile <file>.svf ‐outfile <file>.vme

4. Program the legacy SPI flash.

rsys‐ispVME <file>.vme

Updating the RTM MMC firmware, FRU, and alarm CPLD

These procedures describe how to update the firmware and software for the ATCA‐540x RTM  and ATCA‐4580 RTM.

Determine IPMB and IPMB‐L addresses to complete the RTM firmware and FRU updates. See 

Appendix B, IPMB and IPMB‐L address mapping, on page 85

 for information about RTM and 

AMC IPMB‐L addresses. For further details, refer to the specific shelf or carrier  documentation.

60

Board-level updates for the ATCA-45xx CPM and RTM 6

Update the RTM MMC firmware

Update the firmware using rsys‐ipmitool and the *.hpm firmware image.

1. Run rsys‐ipmitool with the following syntax: rsys‐ipmitool ‐I lan ‐H <Shelf IP Address> ‐A none ‐T <Carrier IPMB Address> ‐B 

0 ‐t <RTM IPMB‐L Address> ‐b 7 hpm upgrade <Upgrade Image> activate

Example: rsys‐ipmitool ‐I lan ‐H 10.2.113.200 ‐A none ‐T 0x86 ‐B 0 ‐t 0x90 ‐b 7 hpm  upgrade upgrade.hpm activate

Note: Some Shelf Managers may require authentication. If  ‐A none  does not allow an 

RMCP connection, refer to the Shelf Management documentation and  rsys‐ipmitool ‐‐ help  to determine how to establish an RMCP session.

2. The tool may warn about the possibility of services being interrupted during the upgrade  process, although most often they will not be. Enter  y  to continue.

Components are skipped if the tool determines they are already up to date. This is  especially important for the bootloader. If the firmware is reset or loses power while  updating the bootloader, the module may need to be returned to the factory.

3. Use the following command to verify the upgrade: rsys‐ipmitool ‐I lan ‐H <Shelf IP Address> ‐A none ‐T <Carrier IPMB Address> ‐B 

0 ‐t <RTM IPMB‐L Address> ‐b 7 hpm check <Upgrade Image>

Update the RTM FRU data

Update the RTM FRU information and (optionally) set the hard disk drive information by  entering these rmcpta commands: rmcpta ‐h <Shelf IP Address> targetfwd <Carrier IPMB Address> <RTM IPMB‐L Address> setdriveinfo (see Using setdriveinfo on page 22 for details) updatefru <RTM FRU Update File> backup.bin

Enter  help  on the rmcpta command line for a list of available commands.

Before updating the device FRU data, the current data is saved to the file backup.bin, which  can be used to recover the information.

During the update process, you may be prompted for input to resolve differences in format  between the old and new FRU data. You may also receive a warning if the update file does not  match the targeted device to prevent it from being updated with incorrect data. Use the  ‐‐ auto  option to avoid prompts.

61

Board-level updates for the ATCA-45xx CPM and RTM 6

Customize the RTM FRU data during an update

If you need to customize RTM FRU data, the customization can be accomplished during the 

FRU update process by specifying the  ‐‐full  option for the updatefru command.

rmcpta ‐h <Shelf IP Address> targetfwd <Carrier IPMB Address> <RTM IPMB‐L Address> updatefru <RTM FRU Update File> backup.bin ‐‐full

This is a sample of the FRU update prompts, with the selected options shown in bold:

Reading in the FRU data update file...

Decoding the template FRU data...

Retrieving the current device FRU 0 data..................................

Backing up the data to file backup.bin...

Decoding the current FRU data...

Merging the FRU information...

Enter byte for header format version (old = 0x01, template = 0x01)0x01

Enter  0x01  to choose the data from the device.

Enter  0x01  to choose the data from the supplied template file.

Note: Both values can be  0x01 , depending on the device and file header format version.

Input data:

0000 01.

Is this correct? [yes/no]yes

Enter  yes  if the data is correct.

Internal use area data on device:

None

Internal use area data in template:

None

0‐Old data, 1‐Template data, 2‐Enter data

Select data to use:

Enter  0  to choose the data from the device.

Enter  1  to choose the data from the supplied template file.

Enter  2  to enter your own customized FRU data.

Additional similar prompts follow, but are not shown here. Follow the instructions in the  prompts and enter the customized FRU data.

Note: It is important to enter any required data in the FRU multirecord areas during RTM FRU  customization. Incomplete FRU multirecord data can produce RTM initialization problems. 

The following is an example of FRU multirecords:

Product Extra     :

 OEM (0xRadisys Corporation) Record

 PICMG Extension Record

  FRU_AMC_CURRENT

 PICMG Extension Record

  FRU_AMC_P2P

 PICMG Extension Record

  Unknown OEM Extension Record ID: 2d

62

Board-level updates for the ATCA-45xx CPM and RTM 6

Using setdriveinfo

The  rmcpta setdriveinfo

 command sets the drive information for the type of hard disk drive  installed on the RTM (SAS or SATA). This procedure is needed only if you change the hard disk  drive on the RTM.

1. Complete the following fields:

Enter the number of drives installed (1): 

Enter the drive type, 0 ‐ FC, 1 ‐ SATA, 2 ‐ SAS, 0xFF ‐ None (0xFF): 2

Enter drive manufacturer name (  ): 

Enter drive model (  ): 

Enter drive serial number (  ): 

Enter the desired number of custom info fields (0):

The entered information is displayed to verify the entries:

#   Radisys Record ID        = 0x0A Drive Information Record

#   Record Format Version    = 0x00

#   Drive Number 1

#       Drive Type           = SAS (0x02)

#       Manufacturer Name    =   

#       Model                =   

#       Serial Number        = 

2. Write the data to the device by entering  yes :

Write the data to the device? [yes/no] yes

Writing the data back to the device FRU 0 information area...

Detected support of Radisys OEM Group Write FRU Data command. (0x2E 0x0A)

Verifying the FRU information and completing the update

To complete the FRU update process, execute the parsefru command to verify the updated 

FRU information.

rmcpta ‐h 10.2.113.200

targetfwd 0x86 0x90 setdriveinfo updatefru ATCA‐5400‐RTM‐FRU‐v01‐00.fru backup.bin

parsefru 0

Update the RTM FRU data on a non-Radisys shelf

Use the  rmcpta OpenSession  command to upgrade the RTM IPMC FRU on a non‐Radisys shelf. 

The following example uses a CMM to update the RTM FRU: rmcpta ‐h <Active‐CMM‐IP>

OpenSession 14 4 2 root cmmrootpass targetfwd <Carrier IPMB Address> <RTM IPMB‐L Address> setdriveinfo (optional ‐ only used if a hard disk drive is installed) updatefru <RTM FRU Update File> backup.bin

63

Board-level updates for the ATCA-45xx CPM and RTM 6

The following list defines the OpenSession command options:

• 14  is the IPMI channel number

• 4  is the requested privilege level

• 2  is the requested authentication type

• root  is the default username

• cmmrootpass  is the default user password

Update the RTM alarm CPLD

The procedures for updating the CPLD for the RTM are similar to the procedures in  Update the 

legacy FPGA on page 58

. See that section for the two RPM files that need to be installed  based on your OS. The following svf file for updating the alarm CPLD is in the ATCA‐5400‐RTM‐

<version>/firmware/cpld folder on the Promentum software release: cpm7_alarm_commux_bypass_legacy_bypass.svf

The following are example steps to program the alarm CPLD from a running RH5 system. 

Modify the file names according to your OS. These steps must be performed with root  permissions.

1. Install or update the required software packages.

rpm ‐Uvh ispVMEmbedded‐1.2‐5.x86_64.rpm cpm_ioport_module‐1.05‐

1.2.6.18_164.el5.x86_64.rpm

2. Start the ioport service. This step can be skipped if you have rebooted or already started  the ioport service since installation of the above software packages.

/etc/init.d/cpm_ioport_module start

3. Convert the CPLD svf file to vme. Note that the ISP tools require lower case extensions.

rsys‐svf2vme ‐infile <file>.svf ‐outfile <file>.vme

4. Program the alarm CPLD.

rsys‐ispVME <file>.vme

5. Verify the RTM alarm CPLD version: dd if=/dev/port bs=1 count=1 skip=1580 2>/dev/null | xxd

The version output may be similar to the following, which shows the alarm CPLD version is 

8:

0000000: 81

64

Board-level updates for the ATCA-45xx CPM and RTM 6

Updating the RTM SAS firmware

The sasflash utility updates the LSI SAS firmware for the ATCA‐5400 and ATCA‐5401 RTM. The 

sasflash update file and two other files must be added to a USB flash drive to initiate the  update.

Follow these steps to update the LSI SAS on the RTM:

1. Contact Radisys Support to get the correct sasflash.efi update file for your RTM and CPM  operating system.

2. Copy these files to a USB flash drive:

• sasflash.efi provided by Radisys Support

• CP7_RA_xx.fw

• mptsas_xx_xx_xx_xx.rom

Note: Files CP7_RA_xx.fw and mptsas_xx_xx_xx_xx.rom are located in the ATCA‐5400‐

RTM bundle on the Promentum software release media.

3. Boot the CPM to the EFI shell.

4. Insert the USB flash drive into a USB port on the CPM.

5. Enter these commands to mount the USB flash drive: reconnect ‐r map ‐r fs0:

Note: The fs0 enumeration assumes only one USB device is installed. Additional USB  devices may produce a different enumeration.

6. Enter this command from the CPM EFI shell to update the SAS firmware and BIOS image: sasflash.efi ‐o ‐f <FW file> ‐b <MPT BIOS file>

<FW file>  is CP7_RA_xx.fw, and  <MPT BIOS file>  is mptsas_xx_xx_xx_xx.rom on the USB  flash drive.

7. The following prompt may appear if an older version of the LSI firmware is being  upgraded:

Product ID and Vendor ID do not match. Would you like to flash anyway [y/n]?

Enter  y  to flash the firmware. The following message appears if the upgrade is successful:

Finished Processing Commands Successfully. Exiting SASFlash.

8. To verify the update, run this command to list information about the updated SAS  controller: sasflash_ebc.efi ‐o ‐list

65

Board-level updates for the ATCA-45xx CPM and RTM 6

Compare the following example output with the information displayed on your adapter:

******************************************************************

    LSI Corporation SAS FLASH Utility.

    SASFlash Version 1.20.00.00 (2008.10.31)

    Copyright (c) 2006‐2007 LSI Corporation. All rights reserved.

******************************************************************

    Advanced Mode Set

    Adapter Selected is a LSI SAS 1064E(B1):

Controller Number:               1

Controller:                      1064E(B1)

PCI Address:                     00:05:00:00

SAS Address:                     XXXXXXX‐X‐XXXX‐XXXX

NVDATA Version (Default):        0x2D07

NVDATA Version (Persistent):     0x2D07

Product ID:                      0x2704

Firmware Version:                01.27.00.00

NVDATA Vendor:                   LSILogic

NVDATA Product ID:               ATCA‐5400

BIOS Version:                    06.26.00.00

BIOS Alternate Version:          N/A

EFI BSD Version:                 N/A

FCODE Version:                   N/A

Finished Processing Commands Successfully.

    Exiting SASFlash.

Downgrading a CPM to an earlier firmware version

It may be necessary to downgrade the modules in the CPM to an earlier firmware version if  image corruption or incompatibilities occur that cannot be corrected.

A CPM downgrade is done by acquiring the CPM firmware update bundle for the version to  which you want to downgrade. Either run rsys‐update and specify the downgrade version of  the .tgz update bundle, or perform board level updates using the tools and software and  firmware update files in the downgrade .tgz update bundle.

Using rsys-update

1. Downgrade the first bank for the CPM using rsys‐update and the downgrade version of the  update bundle.

rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic

2. Downgrade the second bank for the CPM using the update bundle.

rsys‐update ‐‐path /<tmp‐dir>/<update‐bundle> ‐‐automatic ‐‐redundant

66

Board-level updates for the ATCA-45xx CPM and RTM 6

Using board level updates

Manual CPM component downgrades are accomplished using the CPM update procedures in 

this chapter, beginning on  page 46 . Use the tools, scripts and utilities in the downgrade 

version of the CPM update bundle.

67

Chapter

7

Updating and customizing FRU data

This chapter describes the procedures used to update or customize FRU data for a FRU or  shelf. Radisys occasionally updates the functional aspects of FRU data, including PICMG point‐ to‐point connectivity records, with corrections or enhancements. The update procedures  preserve the FRU‐specific information, such as the serial number. These procedures customize  certain fields while preserving the functional aspects of the FRU data.

The procedures apply to:

• The Promentum shelves

• Some Promentum front modules and the CE3100 COM Express module

• The ATCA‐5010 and ATCA‐5014 SPMs

For AMC and RTM FRU data updates, see  Chapter 8, Updating IPMI FW and FRU data for an 

AMC or RTM, on page 72

.

Customizing FRU-specific data

The frugen.pl PERL script prompts for new values for the user‐definable fields in an existing 

FRU data image. The script creates a new binary image containing the functional FRU data  and any custom values. Specify in a configuration file which of the user‐definable fields to  overwrite in the FRU device. Use the configuration file and the image created to write the 

custom values to the FRU device as described in  Updating FRU data using fru_update on  page 70 .

Prerequisites:

frugen<version>.pl PERL script, which should be renamed to frugen.pl

• Math::BigInt, Getopt::Long, and Time::Local PERL modules installed

fru_update script

frutool and rsys‐ipmitool in the PATH environment variable on the Linux host where you  run fru_update

• Files with names ending in CustomFields.cfg and CustomFields.sf for customizing the user‐ definable fields

Procedure:

1. Determine the data to enter into the user‐definable fields. These fields are customizable:

Chassis Info Area (for shelf FRU data only):

Chassis Custom 2

Chassis Custom 3

Chassis Custom 4

68

Updating and customizing FRU data 7

Board Info Area:

Board Product Name

Board Part Number

Board Custom 1

Board Custom 2

Board Custom 3

Product Info Area:

Asset Tag

Product Custom 1

Product Custom 2

Product Custom 3

2. From a Linux host, compile the custom fields .sf file into a .bin file: frugen.pl ‐f <sf_file>.sf ‐o <bin_file>.bin

<bin_file> is the name of the file to be created. Make the <bin_file> base name match the 

<sf_file> base name.

The script prompts to enter a value for each custom field.

3. Enter custom data at the prompts, or leave fields blank to keep the existing value.

Pressing  enter  without entering anything uses the data already in the .sf file, which are  typically blank spaces, or the data on the FRU device (based on the choices made in 

Step 5 ). 

The data entered must match the default length of the field (usually 20 characters). 

Otherwise frugen.pl will prompt again for the same field. Use spaces or other characters  to make the input value match the length required.

The data can alternatively be specified on the command line for scripting purposes. For  example: frugen.pl ‐f <filename>.sf ‐o <filename>.bin ‐noi

‐d "Board Product Name"="Custom BrdProdName  "

‐d "Board Part Number"="Custom BrdPartNum   " ... etc.

     frugen.pl prints an error if the  ‐d  option is missing for any customizable field.

4. Open the custom data .cfg file in a text editor.

5. Uncomment the lines in the file that represent the fields to be overwritten in the FRU  device. To uncomment a line, delete the # character and leave no white space at the  beginning of the line.

To keep the existing data that is in the FRU device for a field, keep the # character in front  of the field. 

69

Updating and customizing FRU data 7

These fields can be uncommented:

Chassis Info Area (for shelf FRU data only):

#CHASSIS REPLACE CUSTOM 2

#CHASSIS REPLACE CUSTOM 3

#CHASSIS REPLACE CUSTOM 4

Board Info Area:

#BOARD REPLACE PRODNAME

#BOARD REPLACE PARTNUM

#BOARD REPLACE CUSTOM 1

#BOARD REPLACE CUSTOM 2

#BOARD REPLACE CUSTOM 3

Product Info Area:

#PRODUCT REPLACE ASSETAG

#PRODUCT REPLACE CUSTOM 1

#PRODUCT REPLACE CUSTOM 2

#PRODUCT REPLACE CUSTOM 3

6. Write the customized fields to the FRU device, as described in  Updating FRU data using 

fru_update on page 70

. Specify the custom fields .cfg and .bin files in the fru_update  command.

Updating FRU data using fru_update

The fru_update shell script can be used for two purposes:

• Update the portions of the functional FRU data that changed to a new version from 

Radisys while preserving FRU‐specific information.

• Modify certain customizable fields in the FRU data while preserving the functional FRU  data.

The fru_update script reads the existing FRU data from the FRU device, then creates a new 

FRU image that combines the existing FRU data with the data to be modified. A configuration  file indicates the parts to modify. The new image is written to the FRU device. A copy of the  original FRU image is saved temporarily and then removed once the update has completed  successfully.

The fru_update script uses the frutool and rsys‐ipmitool executables. fru_update and frutool  verify the files to be used in advance, and also verify the device data after the update.

Prerequisites:

fru_update script

frutool and rsys‐ipmitool in the PATH environment variable on the Linux host where you  run fru_update.

70

Updating and customizing FRU data 7

• One of these pairs of files:

• Files from Radisys with names ending in <version>.cfg and <version>.bin to use for  upgrading the functional FRU information. Do not modify or compile these files before  use. 

• Files with names ending in CustomFields.cfg and CustomFields.bin that are modified  with custom data as described in 

Customizing FRU‐specific data on page 68

.

Note: The files ending in <version>.sf are used for restoring corrupted FRU data only. If you  encounter this situation, contact Radisys Technical Support for assistance.

Procedure:

From a Linux host with LAN access to the target FRU, update the FRU data by entering: fru_update "‐I lan ‐H  <Shelf_Mgr_IP>  ‐A NONE ‐t  <IPMB> " <cfg_file> 

<FRU_image>

<Shelf_Mgr_IP> is the address of the active Shelf Manager. 

<IPMB> is the IPMB address of the FRU to update. To update a shelf’s FRU device, use the 

IPMB address of a proxy FRU that gives access to the shelf FRU device. Use the proxy FRU  for your shelf model:

• For ATCA‐6000, use the IPMB address of the virtual SPM if an ATCA‐5010 or ATCA‐5014 

is installed. See  Table 6   on page 86

 for details about IPMB addresses.

• For ATCA‐6006, use a PEM address. Each shelf FRU device must be updated separately. 

• For ATCA‐6014 and ATCA‐6016, use the virtual RCM address, which updates both shelf 

FRU devices.

<cfg_file> is the name of the FRU data update configuration file ending in .cfg.

<FRU_image> is the binary FRU data file ending in .bin.

Scripts verify the type of FRU being updated against the files provided before writing the data.

Examples:

The following command makes an RMCP connection to the Shelf Manager at IP address 

10.2.113.36 and targets module address 0x82 on the IPMB (an ATCA‐2210).

./fru_update "‐I lan ‐H 10.2.113.36 ‐A none ‐t 0x82" 

ATCA‐2210‐FRU‐v01‐01.cfg ATCA‐2210‐FRU‐v01‐01.bin

This command upgrades the ATCA‐6000 chassis FRU:

./fru_update "‐t 0x50" ATCA‐6000‐FRU‐v01‐06.cfg ATCA‐6000‐FRU‐v01‐06.bin

71

Chapter

Updating IPMI FW and FRU data for an AMC or RTM

8

This chapter describes updating the AMC or RTM IPMI firmware using rsys‐ipmitool and  updating the FRU data for an AMC or RTM using the rmcpta utility.

The following items are required to complete the IPMI firmware and FRU data updates for an 

AMC or RTM:

• A Shelf Manager with RMCP LAN to IPMB bridging and Send Message command support

• A carrier with Send Message command support to AMCs and RTMs

• A Windows or Linux machine able to communicate over a LAN with the Shelf Manager

• The Radisys software tool rmcpta for checking the current firmware version and updating  the FRU data

• The Radisys software tool rsys‐ipmitool for checking the backup firmware version and  updating the IPMI firmware

• An HPM.1 firmware upgrade image (*.hpm)

• A FRU information update file (*.fru)

Determining the IPMI firmware version

To determine the IPMI firmware version for an AMC or RTM, these device addresses need to  be acquired:

• IP address of the Shelf Manager

• IPMB address of the carrier where the AMC is installed

• IPMB‐L address of the AMC or RTM

See 

Appendix B, IPMB and IPMB‐L address mapping, on page 85

 for information about IPMB  and IPMB‐L addresses.

Current firmware version

To check the current firmware version, enter these commands:

1. rmcpta ‐h <shelf IP address>

2. targetfwd <carrier IPMB address> <AMC or RTM IPMB‐L address>

3. getdeviceid

Backup firmware version

To check the backup firmware version, execute this command: rsys‐ipmitool ‐I lan ‐H <shelf IP address> ‐A none ‐T <carrier IPMB address> ‐B 0 

‐t <AMC or RTM IPMB‐L address> ‐b 7 hpm check

72

Updating IPMI FW and FRU data for an AMC or RTM 8

Updating the IPMI firmware

The IPMI firmware for an RTM or AMC is updated using rsys‐ipmitool. Update the AMC or 

RTM IPMI firmware by following these steps:

1. Access the Linux or Windows command prompt.

2. Change directory to the location of the extracted AMC or RTM firmware images and tools.

3. Determine the following:

• IP address of the Shelf Manager (not necessary if the OpenIPMI driver is used)

• IPMB address of the module where the AMC is installed, or the module associated  with the RTM (not necessary if upgrading from the local LMP or CPU over OpenIPMI)

• IPMB‐L address of the AMC or RTM

See 

Appendix B, IPMB and IPMB‐L address mapping, on page 85

 for details about IPMB and 

IPMB‐L addresses.

The IPMI firmware can be updated using these methods:

• Shelf Manager

• OpenIPMI

Using the Shelf Manager

The following command updates the IPMI firmware using rsys‐ipmitool through the Shelf 

Manager, specifying the *.hpm AMC or RTM firmware image: rsys‐ipmitool ‐I lan ‐H <shelf IP address> ‐A none ‐T <carrier IPMB address> ‐B 

0 ‐t <AMC or RTM IPMB‐L address> ‐b 7 hpm upgrade <.hpm upgrade image> activate  noprompt

This example updates an AMC at address 0x7A: rsys‐ipmitool ‐I lan ‐H 10.2.113.200 ‐A none ‐T 0x86 ‐B 0 ‐t 0x7A ‐b 7 hpm  upgrade upgrade.hpm activate noprompt

Some Shelf Managers may require authentication. If 

‐A none

 does not allow an RMCP  connection, refer to the Shelf Management Software Reference manual and  rsys‐ipmitool ‐‐ help  to determine how to establish an RMCP session.

Using OpenIPMI

The following command updates an AMC or RTM for a module from the module’s LMP or 

CPU: rsys‐ipmitool ‐t <AMC/RTM IPMB‐L Address> ‐b 7 hpm upgrade <Upgrade Image>  activate noprompt

The following command updates an AMC or RTM on a different module from a module’s LMP  or CPU: rsys‐ipmitool ‐T <Carrier IPMB Address> ‐B 0 ‐t <AMC/RTM IPMB‐L Address> ‐b 7  hpm upgrade <Upgrade Image> activate noprompt

73

Updating IPMI FW and FRU data for an AMC or RTM 8

Reviewing the output

The output from the IPMI firmware update commands should resemble the following  example:

PICMG HPM.1 Upgrade Agent 1.0:

Validating firmware image integrity...OK

Performing preparation stage...

Services may be affected during upgrade. Do you wish to continue? y/n  y

OK

Performing upgrade stage:

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐

|ID | Name      |    Versions           |    Upload Progress  | Upload| Image |

|   |           | Active| Backup| File  |0%       50%     100%| Time  | Size  |

|‐‐‐|‐‐‐‐‐‐‐‐‐‐‐|‐‐‐‐‐‐‐|‐‐‐‐‐‐‐|‐‐‐‐‐‐‐||‐‐‐‐+‐‐‐‐+‐‐‐‐+‐‐‐‐||‐‐‐‐‐‐‐|‐‐‐‐‐‐‐|

| 1 |AMC Boot   |  X.YY | ‐‐.‐‐ |  X.YY ||       Skip        || ‐‐.‐‐ | ‐‐‐‐‐ |

|*0 |AMC Runtime|  X.YY | ‐‐.‐‐ |  X.ZZ ||...................|| 00.41 | 099d9 |

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐

(*) Component requires Payload Cold Reset

Firmware upgrade procedure successful

Note: Components are skipped if the tool determines they are already up to date. This is  especially important for the bootloader. If the firmware is reset or loses power while updating  the bootloader, the firmware will need to be reprogrammed over JTAG.

Verifying the update

Verify the AMC or RTM IPMI firmware update by executing the following command: rsys‐ipmitool ‐I lan ‐H <shelf IP address> ‐A none ‐T <carrier IPMB address> 

‐B 0 ‐t <AMC or RTM IPMB‐L address> ‐b 7 hpm check <.hpm upgrade image>

Reverting to backup firmware

Use this procedure only if you need to revert to the backup firmware version stored on the 

MMC. After performing the procedure, you will not be able to run the new version again until  a full upgrade is completed.

Enter this command: rsys‐ipmitool ‐I lan ‐H <shelf IP address> ‐A none ‐T <carrier IPMB address> 

‐B 0 ‐t <AMC or RTM IPMB‐L address> ‐b 7 hpm rollback

An 0xD5 error code may be returned if there is no rollback version.

74

Updating IPMI FW and FRU data for an AMC or RTM 8

Updating AMC or RTM FRU data

The FRU data for an AMC or RTM must be updated using the rmcpta utility. Enter  help  on the 

rmcpta command line for a list of available commands.

Update the AMC or RTM FRU data by entering the following commands:

1. rmcpta ‐h <shelf IP address>

2. targetfwd <carrier IPMB address> <AMC or RTM IPMB‐L address>

3. updatefru <FRU update file> backup.bin

Before updating the device FRU data, the updatefru command also saves the current data  to the file backup.bin, which can be used to recover the current FRU data if necessary. 

When updating the FRU data, the utility may prompt for input to resolve differences in  format between the old and new data. It may also warn if the update file does not match  the targeted device to prevent it from being updated with incorrect data. The  ‐‐auto   option can be used to avoid prompts.

This is a FRU data update example with the addresses and file names included: rmcpta ‐h 10.2.113.200

targetfwd 0x82 0x7A updatefru AMC‐72xx‐FRU‐v01‐01.fru backup.bin

parsefru 0

The final  parsefru 0  command verifies the FRU information.

75

Chapter

Installing previous firmware or software versions

9

This chapter describes use of the firmware and tools comprised in an update bundle. 

Firmware is the image that is applied to the hardware, and tools are the update scripts that  apply the firmware to the hardware.

The latest version of tools should be used for upgrades and downgrades. In some cases,  though, you may want to keep the version of the firmware the same in the bundle, but  replace the tools if newer tools address problems you have experienced with the current  tools.

The rfw‐merge utility replaces the tools in the older bundle with the tools in the newer  bundle, creating a new merged bundle with the old firmware and new tools. You upgrade or  downgrade to firmware or software versions prior to the current release using this release’s  update utilities.

Important: Only LMP modules (the ATCA‐1200, ATCA‐2210, ATCA‐7220, and ATCA‐9100) are  downgraded using rfw‐merge. A CPM, such as the ATCA‐4500, does not require a merged 

update bundle for downgrades. See  Downgrading a CPM to an earlier firmware version on  page 66

.

rfw-merge command details

Syntax rfw‐merge [options] <older‐bundle>  <newer‐bundle>

[options]

‐h, ‐‐help  — Prints a brief help message and exits

‐m, ‐‐man  — Prints the manual page and exits

‐V, ‐‐verbose  — Enables verbose output

Required arguments

<older‐bundle>

Firmware bundle file (.tgz) containing the source firmware images.

<newer‐bundle>

Firmware bundle file (.tgz) containing the source tools (for example, rsys‐update and 

rsys‐ipmitool).

76

Installing previous firmware or software versions 9

Example

rfw‐merge ATCA‐7220‐1.10.11‐1‐firmware.tgz ATCA‐7220‐1.11.13‐0‐firmware.tgz

This command creates a new firmware bundle that contains older firmware with the  latest versions of the update tools. Use this new bundle to downgrade the module.

The new firmware bundle created by rfw‐merge is named using this format:

<FRU name>‐<newer‐bundle>‐tools‐<older‐bundle>‐firmware.tgz

Refer to the compatibility matrix in the current Promentum software release notes for  applicable downgrade versions. See the Promentum 3.x to 4.x Firmware and Software 

Upgrade/Downgrade Instructions for more information about performing downgrades.

77

Appendix

A

Sample conf.rfw file

This appendix describes the conf.rfw configuration update file syntax, and lists some sample  files that can be used as guidelines for creating the configuration file.

Configuration file syntax

The rfw‐update configuration files conform to the YAML file format. See  http://search.cpan.org/dist/YAML/lib/YAML.pm

 for details, or run  man YAML  on the module  where YAML is installed.

Keyword descriptions

‐‐‐ bundles: module: path:

Required marker that indicates the beginning of a YAML document. 

Multiple YAML documents can exist in the same file.

Required section that lists the URL to the firmware bundle for each  module type. The required keys are:

<name> of the module type, which is used to identify the bundle

<URL> for the module to update the bundle in the repository. <URL> is  one of: ftp://<user>:<password>@<host>[:<port>]//<update‐bundle> http://<host>[:<port>]//<update‐bundle> https://<host>//<update‐bundle> sftp://<user>:<password>@<host>[:<port>]//<update‐bundle> tftp://<host>[:<port>]//<update‐bundle>

Note: Use FTP or SFTP to achieve the best performance and reduce the  update time.

<password> does not allow certain non‐alphanumeric characters (such  as @, :, or /).

If the <port> is not specified, the default port for the protocol is used.

When used after a double slash (//), <update‐bundle> is the absolute  path of the bundle on the system containing the bundle. When used  after a single slash (/), <update‐bundle> is relative to the default path of  the <user> or protocol.

Note: The HTTP and HTTPS URL formats are not available on the ATCA‐

1200, ATCA‐2210, ATCA‐7220, or ATCA‐9100. On the CPM, support for 

HTTP and HTTPS depends on the installed wget utility. The rfw‐update 

‐‐versions  option checks the accessibility of the bundle using the  specified URL.

Important: Firmware updates and RPMs for the ATCA‐5010 and ATCA‐

5014 SPM are included in the ATCA‐2210 firmware update bundle. In  the conf.rfw file, you specify the path to the ATCA‐2210 update bundle  for the ATCA‐5010 and ATCA‐5014.

78

Sample conf.rfw file A update‐targets: module:

Required section listing the intended update targets. The required keys  are:

<name> of the module type, which is used to verify the target.

connect: <URL> to connect to the module, where  <URL>  is: telnet://<user>:<password>@<host>[:<port>/]

Note: You must have root account access for rfw‐update to operate properly.

The optional keys that perform verification and actions for the  update‐targets  section  are:

Verification keys: chassis: check‐bank: slot:

<0‐255> Verifies the logical chassis number

<0‐1> Verifies the module is booted in the expected bank before  upgrading. The standby bank (the bank not specified here) is always  updated first.

<1‐16> Verifies the physical slot

Note: The rfw‐update process stops if an invalid verification is  encountered.

Action keys: extra‐options: Passes these custom update options directly to rsys‐update when  running the update:

<both> (updates both redundant and non‐redundant components)

Important: If this action key is not specified, by default only redundant components are 

updated. See  Table 1   on page 10

 for a list of redundant and non‐redundant components.

ipmb‐host: ipmb‐target: log: non‐redundant:

<00‐ff> Specifies the IPMB address of the module connected to using  the update‐target URL (used to specify the IPMB address of the ATCA‐

5010 or ATCA‐5014 when updating from an ATCA‐2210).

<00‐ff> Specifies the IPMB address when the target to be updated is  different from the module connected to using the  update‐targets  URL. 

For example, when updating the firmware on the ATCA‐5010 or ATCA‐

5014 SPM, connect to the IP address of the corresponding ATCA‐2210 

SCM and specify the IPMB address of the SPM.

<path> Specifies an alternative log file for this target.

<yes | no> Specifying  yes  updates only the non‐redundant components.

Example: update‐targets :

‐ slot: 13 module: ATCA‐7220 connect: telnet://[email protected]

non‐redundant: yes

This updates only the non‐redundant components for the ATCA‐

7220 in slot 13.

79

Sample conf.rfw file A

‐ path: phase: post‐update: set‐bank: update‐banks:

<URL> Specifies an alternative update bundle location for this target  using the same syntax as the required key  bundles:path .

<0‐999> Specifies a phase group. See 

Set up phase groups on page 22

.

<URL> Specifies a post‐update script to run after the update is run and  the module is rebooted to the updated bank.

<0‐1> Forces the module to reboot to the specified boot bank before  starting the update. The standby bank (the bank not specified here) is  always updated first.

<dual | single> Specifies the number of banks to update. The default is  dual. If a single bank is specified, the bank updated is the standby bank,  which is the bank not in use at the time of update. The  check‐bank  or  set‐bank  option can be used to specify the active bank at the time of the  update.

Required separator between each bundle and  update‐targets

. See  Full 

sample conf.rfw file on page 83 .

Formatting guidelines for conf.rfw

The conf.rfw file must conform to these YAML specifications:

• The file must have two major sections:  bundles  and  update‐targets

• Indentations must be inserted with spaces. Do not use tabs.

• Indentation must be consistent within levels. This example is incorrect:

‐ connect: telnet://[email protected]

module: ATCA‐1200

• The module names in the  bundles  section must match the module names in the  update‐targets  section

• The  connect  targets must be accessible from the system running rfw‐update

• The  path  targets must be accessible from the module to be updated

• Comments can be placed in the file, preceded by a # symbol

If you generate the conf.rfw file by copying the  Full sample conf.rfw file on page 83 , you need 

to properly format the file so rfw‐update can parse it. Modify each key in the  bundles  and  update‐targets  sections so their indentations are consistent between levels. For example,  use four spaces to precede the key names, such as  module  and  path .

Note: Do not use tabs to generate white space in the configuration file.

80

Sample conf.rfw file A

This example shows how to format the file, with the “^” character representing the addition  of a space: bundles:

^^^^module: ATCA‐1200

^^^^path: tftp://192.168.16.1/ATCA‐1200‐1.10.20‐0‐firmware.tgz

update‐targets:

^^^^connect: telnet://[email protected]

^^^^module: ATCA‐1200

If conf.rfw is incorrectly formatted, the following error occurs: root@localhost@1‐2‐1:~#  rfw‐update xbad ‐‐a

**************************************

** Tool version: rfw‐update‐2.0.14‐1 **

**************************************

YAML Error: Invalid element in map

Code: YAML_LOAD_ERR_BAD_MAP_ELEMENT

Line: 4

Document: 1 at /usr/lib/perl5/5.8.0/YAML.pm line 33 root@localhost@1‐2‐1:~#

81

Sample conf.rfw file A

Small sample conf.rfw file

Below is a sample conf.rfw file for updating a lightly populated chassis. A more 

comprehensive conf.rfw file is provided at  Full sample conf.rfw file on page 83

 to copy and  edit for creating a custom file. 

Formatting guidelines for conf.rfw on page 80  need to be 

followed when editing the copied file.

Notice that there are two sections in the file— bundles  and  update‐targets . The  bundles   section is used to specify how each software or firmware update bundle is accessed from the 

target. The  update‐targets  section corresponds to the list of products created.

Important: This simple example only updates the redundant components.

# Simple rfw‐update configuration to update a pair of

# ATCA‐2210s in slots 7 and 8 and an ATCA‐9100 in slot 4.

‐‐‐ bundles:

  ‐ module:  ATCA‐2210

    path:    tftp://10.1.0.1/ATCA‐2210‐<version>‐firmware.tgz

  ‐ module:  ATCA‐9100

    path:    tftp://10.1.0.1/ATCA‐9100‐<version>‐firmware.tgz

update‐targets:

  ‐ slot:    7

    module:  ATCA‐2210

    connect: telnet://[email protected]

  ‐ slot:    8

    module:  ATCA‐2210

    connect: telnet://[email protected]

  ‐ slot:    4

    module:  ATCA‐9100

    connect: telnet://[email protected]

82

Sample conf.rfw file A

Full sample conf.rfw file

The configuration file sample shown below can be copied into a text file, edited as necessary,  and saved as conf.rfw. If this sample is copied, ensure that rfw‐update correctly processes the  file by following the 

Formatting guidelines for conf.rfw on page 80 .

This full conf.rfw sample contains a more comprehensive set of module types and keys than  the small sample, simplifying the editing process by providing a complete file framework.

# Rack12 rfw‐update Configuration 

‐‐‐  bundles:

‐ module: ATCA‐1200 path:   tftp://10.2.0.1/ATCA‐1200‐<version>‐firmware.tgz

‐ module: ATCA‐2210 path:   ftp://fstest:[email protected]//tftpboot/ATCA‐2210‐<version>‐ firmware.tgz

‐ module: ATCA‐4500 path:   tftp://10.2.0.1/ATCA‐4500‐<version>‐mv‐firmware.tgz

‐ module: ATCA‐4500 path:   tftp://10.2.0.1/ATCA‐4500‐<version>‐wr‐firmware.tgz

‐ module: ATCA‐5010 path:   ftp://fstest:[email protected]//tftpboot/ATCA‐2210‐<version>‐ firmware.tgz

‐ module: ATCA‐7220 path:   tftp://10.2.0.1/ATCA‐7220‐<version>‐firmware.tgz

  update‐targets:

‐ module: ATCA‐9100 path:   tftp://10.2.0.1/ATCA‐9100‐<version>‐firmware.tgz

connect:     telnet://[email protected]

module:      ATCA‐1200 slot:        1 phase:       1

‐ connect:     telnet://[email protected]

module:      ATCA‐4500 slot:        5 phase:       1

‐ connect:     telnet://[email protected]

module:      ATCA‐9100

83

Sample conf.rfw file A slot:        10 phase:       1

‐ connect:     telnet://root:[email protected]

module:      ATCA‐4500 slot:        14 phase:       1

‐ connect:     telnet://root:[email protected]

module:      ATCA‐7220 slot:        12 phase:       1

‐ connect:     telnet://[email protected]

module:      ATCA‐2210 slot:        8 set‐bank:    1

‐ connect:     telnet://[email protected]

module:      ATCA‐2210 slot:        7 set‐bank:    0

‐ connect:     telnet://[email protected]

module:      ATCA‐5010 slot:        8 ipmb‐target: e6

‐ connect:     telnet://[email protected]

module:      ATCA‐5010 slot:        7 ipmb‐target: e4

‐ connect:     telnet://[email protected]

module:      ATCA‐1200 slot:        1 phase: 3 extra‐options: ‐‐both

The  ‐‐both  update option must be specified as shown in the full conf.rfw sample or only the  redundant components are updated. In this sample, both the redundant and non‐redundant  components for the ATCA‐1200 are updated in two phases.

Note: The conf.rfw file can also be generated from an example file provided with rfw‐update

See 

Create conf.rfw from example.rfw on page 21  for details.

84

Appendix

B

IPMB and IPMB-L address mapping

This appendix supplements  Chapter 8, Updating IPMI FW and FRU data for an AMC or RTM,  on page 72 .

Table 6   on page 86  provides the IPMB addresses of ATCA front modules, Power Entry Modules 

(PEMs), fan modules, and Shelf Peripheral Modules (SPMs) in Radisys ATCA shelves. The  hexadecimal addresses in these tables may not be correct for shelves made by other  manufacturers. If you are using a third‐party shelf, refer to the shelf's documentation for its 

IPMB addresses.

85

IPMB and IPMB-L address mapping B

Table 6. IPMB addresses in hexadecimal notation

Slot or FRU

Active Shelf Manager

Front slot 1

Front slot 2

Front slot 3

Front slot 4

Front slot 5

Front slot 6

Front slot 7

Front slot 8

Front slot 9

Front slot 10

Front slot 11

Front slot 12

Front slot 13

Front slot 14

Front Slot 15

Front Slot 16

PEM 1 (left PEM when viewed from rear)

PEM 2 (right PEM when viewed from rear)

IPMB address / location

ATCA-6000 shelf

20

9A

96

92

8E

8A

86

82

84

88

8C

90

94

98

9C n/a n/a

C4

C6

Fan 1 (viewed from front) C8 / Left top AMM

Fan 2 (viewed from front) CA / Right top AMM

ATCA-6006 shelf

20

82

84

86

88

8A

8C n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a

66

68

5A / Right fan tray

5C / Left fan tray

Fan 3 (viewed from front) CC / Left recessed AMM n/a

Fan 4 (viewed from front) CE / Right recessed AMM n/a

50 n/a Virtual SPM (represents the active ATCA-5010 or

ATCA-5014 SPM)

SPM 1 (rear slot 7)

SPM 2 (rear slot 8)

Virtual RCM (represents the active RCM)

E4

E6 n/a n/a n/a n/a

RCM 1 (left)

RCM 2 (right)

Shelf alarm panel n/a n/a n/a n/a n/a

52

ATCA-6014 shelf

20

9A

96

92

8E

8A

86

82

84

88

8C

90

94

98

9C n/a n/a

60, FRU ID 6

60, FRU ID 7

60, FRU ID 3 / Left fan tray

60, FRU ID 4 / Center fan tray

8C

90

94

98

86

82

84

88

96

92

8E

8A

ATCA-6016 shelf

20

9E

9A

9C

A0

60, FRU ID 6

60, FRU ID 7

60, FRU ID 3 / Left fan tray

60, FRU ID 4 / Center fan tray

60, FRU ID 5 / Right fan tray 60, FRU ID 5 / Right fan tray n/a n/a n/a n/a n/a

60

10

12 n/a n/a n/a n/a

60

10

12 n/a

86

IPMB and IPMB-L address mapping B

Table 7  provides the local IPMB addresses (IPMB‐L) for AMC and RTM devices, which is the 

IPMB from the carrier manager to the module. Each AMC and RTM connects to IPMB‐L  through a module management controller (MMC).

The hexadecimal addresses in this table may not be correct for shelves made by other  manufacturers. If you are using a third‐party shelf, refer to the shelf's documentation for its 

IPMB‐L addresses.

To comply with the AMC.0 specification, AMC IPMB‐L addresses are always in the even  numbered range of 0x70‐0xA4.

Table 7. IPMB-L addresses in hexadecimal notation a

AMC device

AMC1 a module management controller (MMC)

AMC2 MMC

AMC3 MMC

AMC4 MMC

RTM MMC

AMC1 is usually the topmost AMC bay of a given board.

IPMB-L address

0x7A

0x7C

0x7E

0x80

0x90

The IPMB‐L addresses are valid for the following modules:

• ATCA‐1200 Quad AMC Carrier

• ATCA‐4300 Compute Processing Module

• ATCA‐4310 Compute Processing Module

• ATCA‐4500 Compute Processing Module

• ATCA‐4550 Compute Processing Module

• ATCA‐4555 Compute Processing Module

• ATCA‐4580 Compute Processing Module

• ATCA‐7220 Packet Processing Module

• ATCA‐9100 Media Resource Module

87

Appendix

Power cycling after IPMC FPGA upgrades

C

Some Radisys products require a 48 V power cycle to activate new IPMC FPGA programming if  the IPMC FPGA is updated. A 48 V power cycle is accomplished using one of these methods:

• Removing the module from the shelf and then reinserting it

• Removing and reapplying 48 V to the entire shelf

The need to perform the power cycle depends on a variety of conditions, which are described  in this appendix.

Power cycle requirements

Table 8  lists Radisys products, their FPGA version updates, and 48 V power cycle  requirements.

Table 8. Power cycle requirements

Product

ATCA-1200

ATCA-4300

ATCA-7220

ATCA-2210

Current

FPGA

ATCA-4500, ATCA-4550, ATCA-4555 3.77(.00)

ATCA-5014 2.08(.00)

3.07(.00)

3.27(.00)

3.07(.00)

2.51(.00)

Previous

FPGAs

3.72(.00) none none none none

2.06(.00)

Power cycle required on FPGA update

No

No

Yes

Yes

Yes

No, if either of the following conditions are met:

• The hardware version is 061-xxxxx-0030 or later and the

IPMC FW version is 5.60 or later from ATCA 3.x.x

Notes

ATCA-4310 3.28(.00) 3.27(.00)

• The IPMC FW version is 4.00.00 or later from ATCA 4.x.x and the IPMC FPGA version is 2.51 or later

No, if all of the following conditions are met:

• The hardware version is 061-xxxxx-0010 or later

• The IPMC FW version is 1.08 or later from ATCA 3.x.x

• The IPMC FPGA version is 3.28 or later

No, if all of the following conditions are met:

2, 3

ATCA-5010 2.08(.00) 2.06(.00)

• The hardware version is 061-xxxxx-0012 or later

• The IPMC FW version is 1.26 or later

• The IPMC FPGA version is 2.08 or later

Notes:

1. ATCA-2210 IPMC FW 5.59 or earlier will always read FPGA 2.06. Contact Radisys Support for the actual FPGA version.

2, 3

2. ATCA-2210, ATCA-4310, and ATCA-5010 FPGA updates are provided in ATCA 3.5.0 and later ATCA 3.x.x releases, and all ATCA 4.x.x releases. These FPGA updates were provided specifically to allow support for no-reboot IPMC FPGA updates.

3. ATCA 3.x.x software returns versions in the x.yy format; ATCA 4.x.x software returns versions in the xx.yy.zz format.

3

3

3

3

3

1, 2, 3

88

advertisement