24-hour/Weekly Time Switch
H2F
Up to 96 ON/OFF Cycles from DIN-sized
(72 x 72 mm) Timer
• Easy setting with color-coded programming tabs.
• Choose 24-hour or 1-week models with either SPST-NO or
SPDT control outputs.
• Minute dial assures accurate settings.
• Models with memory protection available.
• Control outputs can be manually turned ON/OFF.
• Designed for surface, flush, or track mounting.
Model Number Structure
■
Model Number Legend
H2F-
@@@@
1 2 3 4
1. Operation cycle
D: 24-hour
W: 1-week
2. Motor type
None: Synchronous motor
M: Quartz motor
3. Mounting method
None: Flush mounting
F: Surface mounting, DIN track mounting
4. Output type
None: SPST-NO
C: SPDT
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
24-hour/Weekly Time Switch
H2F 1
Ordering Information
Mounting method
Flush
Surface/track
Control output
SPST-NO
SPDT
SPST-NO
SPDT
24-hour operation
Synchronous motor Quartz motor (with memory protection)
H2F-D
H2F-DC
H2F-DM
H2F-DMC
H2F-DF
H2F-DFC
H2F-DMF
H2F-DMFC
■
Accessories (Order Separately)
Extra programming tabs
Rechargeable Battery
1 pair for each ON/OFF (see note)
Note: 24-hour type is supplied with three pairs of programming tabs.
1-week type is supplied with seven pairs of programming tabs.
Y92S-21
Y92S-22
1-week operation
Quartz motor (with memory protection)
H2F-WM
H2F-WMC
H2F-WMF
H2F-WMFC
Specifications
■
Time Ranges
24-hour
1-week
Operation period
■
ON/OFF Cycle
Operation period
Maximum cycles
15 min
1 hr
Minimum division
15 min
2 hrs
Minimum set time
24-hour
Maximum set time
23 hrs 45 min
166 hrs
1-week
96 84
■
Ratings
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Terminal screw tightening torque
Synchronous motor: 100/110/120 VAC, 200/220/240 VAC (50/60 Hz) (see note)
Quartz motor: 100 to 240 VAC (50/60 Hz)
85% to 110% of rated supply voltage
Synchronous motor: 3 VA max.
Quartz motor: 1 VA max. at 100 to 120 VAC, 4 VA max. at 200 to 240 VAC
15 A at 250 VAC, resistive load, SPST-NO, SPDT
0.98 N·m max.
Note: Select the appropriate frequency using the frequency selector switch provided on the upper part of the rear panel.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
2 24-hour/Weekly Time Switch
H2F
■
Characteristics
Item 24-hour operation
Synchronous motor
Accuracy of operating time (see note 1)
±
3 min max.
Influence of voltage
1-week operation
Quartz motor
±
30 min max.
Influence of temperature
Setting error (see note 2)
Cyclic error
Dielectric strength
±
3 min max.
±
3 min max.
Memory protection against power failure ---
Insulation resistance 100 M
Ω
min. (at 500 VDC)
180 hrs min. (see note 3)
±
±
30 min max.
30 min max.
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and non-current-carrying metal parts)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 16.7 Hz, 2-mm single amplitude
Malfunction: 10 to 55 Hz, 0.25-mm single amplitude
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Destruction: 1,000 m/s 2
Malfunction: 200 m/s 2
Operating: –10
°
C to 55
°
C
Operating: 35% 85%
Contacts:
Motor:
10,000 operations min.
20,000 hours
Approved standards
Case color
Weight
UL917, CSA C22.2 No. 14
Light gray (Munsell 5Y7/1)
Flush mounting: approx. 150 g
Surface mounting:approx. 200 g
Note: 1. Accuracy of operating time of when the timer is ON or when the timer is OFF.
2. Difference between the set and actual operation time with the pointer set to the present time.
3. When the timer is used for the first time after energization of 72 hrs.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
24-hour/Weekly Time Switch
H2F 3
Connections
Synchronous Motor Model
(SPST-NO Output)
H2F-D H2F-DF
(SPDT Output)
H2F-DC H2F-DFC
Quartz Motor Model
(SPST-NO Output)
H2F-DM/H2F-WM H2F-DMF/H2F-WMF
(SPDT Output)
H2F-DMC/WMC H2F-DMFC/WMFC
2
Note: Connect an independent power source to the load.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
4 24-hour/Weekly Time Switch
H2F
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Mounting Dimensions
Surface Mounting: H2F-DF/-DMF/-WMF
Track Mounting: H2F-DFC/-DMFC/-WMFC
M3.5
Flush Mounting: H2F-D/-DM/-WM/-DC/-DMC/-WMC
6
29
Mounting Holes
Two, M3 holes
Screw size
M3 x 45
(included)
65.5
Panel Cutout
Recommended panel thickness: 1 to 3.2 mm
Note: The mounting adapter and screws are included.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
24-hour/Weekly Time Switch
H2F 5
Precautions
Flush Mounting
1. To mount the adapter to the panel cutout, first deform the adapter by pushing it on the two opposing corners (as indicated by arrows
A. Then push part B into the cutout (i.e., toward the back of the panel).
Panel
Adapter
3. If the lead wires have been connected to the timer from the front of the panel before the timer is mounted in the panel, engage the timer to part A of the adapter and push it in the direction of B.
Then tighten the two screws as described in 2.
Panel
B
B
A
2. After the adapter is mounted, insert the timer as shown in the figure below. Secure the timer by tightening the two mounting screws (M3 x 45) included as accessories.
Lead wire
A
Time Setting
To set the time, turn the center knob clockwise to the correct time.
Turning it counterclockwise or turning it with your fingers hooked on the setting bracket may cause a malfunction.
With 24-hour models, set the hour to the arrow on the upper left corner of the front panel and the minute to the arrow on the center knob.
With 1-week models, set the day of the week to the arrow on the upper left corner of the front panel and the hour to the arrow on the center knob.
Use the gold setting tabs to set the ON time and the silver ones to set the OFF time. Position the thick leg of the tab toward the outside of the dial and insert the tab securely into the groove on the dial.
Three pairs of setting tabs are attached.
Store the spare tabs in the compartment at the lower right corner of the front panel.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
6 24-hour/Weekly Time Switch
H2F
Manual Switch
SPST-NO Output
A 3-position selector switch, located at the lower left corner of the front panel, determines output operation. In the OFF position, the control output is forcibly turned OFF regardless of the setting of the programming tabs. Set to the AUTO position, the output is turned ON and OFF according to the settings of the programing tabs. In the ON position, the output is forcibly turned ON regardless of the setting of the programming tabs.
SPDT Output
When the manual switch at the lower left corner of the front is set to the OFF position, both load 1 (connected across terminals 4 and 5) and load 2 (across 5 and 6) are turned OFF.
H2F-
@
M Series (Quartz Motor Models)
Battery
Remove the battery cover on the rear panel of the H2F, load the provided Battery into the battery box, then turn ON the H2F. Be sure to load the Battery before using the H2F. If the Battery is not loaded, the power indicator will flash and the H2F will not work properly.
Press down.
Battery cover
Slide out
When it is set to the AUTO position, the output is turned ON and OFF according to the setting of the programming tabs.
When the manual switch is set to the ON position, load 1 (connected across terminals 4 and 5) is turned ON and load 2 (across 5 and 6) is turned OFF.
Be sure to load the Battery with the correct polarity. The polarity is indicated in the battery box. After loading the Battery, be sure to place the cover on the battery box.
Battery
Output Indicator
The output indicator at the upper left corner of the front panel shows the status of the output when the manual switch is set to the AUTO position.
In addition, the output can be manually turned ON or OFF by rotating the knob clockwise (in the arrow direction). The knob will not turn counterclockwise.
Note on H2F-D, -DF Series (synchronous motor versions)
Before using the timer, select the appropriate frequency of your area by the frequency selector switch provided on the upper part of the rear panel.
The Battery is fully charged before shipment. The Battery may lose its charge while the Battery is stored. Therefore, there is a backup function that is guaranteed for 180 hours on condition that the Battery is loaded into the H2F and charged continuously for 72 hours. If the Battery has no charge, the H2F may not operate immediately after it is turned ON. In that case, continue providing power to the
H2F for three or more minutes before setting the time.
If the H2F is turned ON and OFF frequently, the Battery life will be greatly reduced. Use the H2F with a continuous supply of power.
The Battery has a life of approximately three years. If three years have passed since the Battery was loaded, replace the Battery as soon as possible with a AAAA-size NiCd rechargeable battery.
If the H2F is idle over a long time, unload the Battery from the H2F and store the Battery separately in order to prevent the Battery from being overly discharged.
Upper part of rear panel
(cycles per second)
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
24-hour/Weekly Time Switch
H2F 7
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. L013-E1-04 In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Industrial Control Components Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7119/Fax: (81)75-344-7149
Printed in Japan
0203-0.5C (0696) (S)
8
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project