Application
Asynchronous Modems MA-12, MA-12DC,
MA-19
Point-to-point communication is often used to communicate over long
distances between different units, e.g. a computer, a printer or a robot.
These modems allow you to extend the distance to 18,000 m, with a
transmission speed of up to 38,400 bit/s.
·
·
·
·
·
·
·
·
·
·
·
When the distance between the connected units is greater than 15
metres.
Protects connected units from lightning/transients
When the environment is exposed and there is a chance of interference
Functions independently of codes
Transmits status signals
When the devices to be connected have different earth potentials
(earthing points)
Guarantees reliable long-distance communication
Guarantees high performance and reliable functionality
Stand-alone, MA-12
Rack-mounted, MA-19
DC, MA-12DC
Technical data
Transmission
Interface 1
Interface 2
Transmission
speed
Isolation
voltage
Surge
protection
Asynchronous, full/half duplex or simplex
EIA RS-232-C/CCITT V.24/V.28, 25-pin
D-sub, female
10 mA balanced current loop, half/full duplex
(two twisted pairs) 5-pin screw block
Speeds up to 38,400 bit/s
1,500 V* or 500 V, 1000 V**/***
Mains: breakdown voltage 220 V at 115
VAC * 440 V at 220 VAC, Interface 2:
breakdown voltage transmitter 15 V, receiver
5.8 V, discharge 0.6 kW for1 ms
Technical data
Isolation
Galvanic isolation with optocoupler (data
transmission) and transformer (power supply)
Power supply Switchable 115/230 VAC ± 10%, 48-62 Hz
or 12-36 VDC**
Power
Max 4 VA at 230 V, 3 W (DC)**
consumption
Temp/humidity Temp: 5-50 ¡C, ambient
range
temperature/Humidity: 0-95% RH, without
condensation
Dimensions, 161x139x53, 100x100***
mm
Weight, kg
0.5, 0.1***
Transformer Internal, PS-02, via rack***
LEDs
Power, TD, RD, RTS, DCD
*MA-12, **MA-12DC, ***MA-19
Terminal connections
I
O
I
O
O
O
I
I
I
I
25-pin
D-sub
2
3
4
5
6
7
6
9
10
11
19
20
25
CCITT
V.24
Code
103
104
105
106
107
102
109
120
108/2
133
Signal name
TD/Transmitted data
RD/Received Data
RTS/Request To Send
CTS/Clear To Send
DSR/Data Set Ready
SG/Signal Ground
DCD/Data Carrier Detect
PWR +12V
PWR Ð12V
AUX/Auxiliary
SRS/Secondary Request To Send
DTR/Data Terminal Ready
RFR/Ready For Receiving
I=Input into modem O=Output from modem
Transmission distance
The modems transmit data over two twisted pair cables at full/half duplex
and over one pair at simplex. The transmission speed depends on the
Cable 0.3 mm2/42 pF/m resistance and capacitance of the cable. We recommend the use of cables
with at least a 0.2 mm2 cross-section and with a capacitance of between
40-80 pF/m in industrial environments. In office environments, we
Metres Bit/s
recommend at least 0.14 mm2 and a capacitance of between 40-100 pF/m.
500
38400
Use shielded cable in exposed industrial environments and unshielded cable
1000
19200
in less exposed areas and office environments. A shielded cable often
2500
9600
results in a higher capacitance and, thereby, a lower maximum transmission
5000
4800
speed.
8000
2400
12000
1200
18000
600
MA-12 specifications
Transmission:
Asynchronous, full/half duplex
or simplex
Interface 1:
EIA RS-232-C/CCITT V.24/V.28
25-position D-sub female, DCE
Interface 2:
±10mA tri-state balanced current
loop
Data rate:
0-38400bit/s
Indicators:
Power, RD, DCD, RTS, TD
Insulation:
Galvanic insulation with
opto-coupler (data transmission)
and transformer (supply)
Insulation voltage: 1500V
Overvoltage
protection:
Mains: Breakdown voltage 440V at
230V AC and 220V at 115V AC
Interface 2: Breakdown voltage
transmitter 15V and receiver 5.8V
Surge capacity 0.6kW for 1 ms
Power supply:
Switchable 115/230V +15/-10%
48-62Hz
Fuse:
100mA fast 5x20mm
Power consumption: Max 4VA at 230V
Temperature range: 5-50° C, ambient temperature
Humidity:
0-95% RH, non-condensing
Dimensions:
161x139x53mm
Weight:
0.5kg
Mounting:
With rubber pads or screws.
Screws: Remove the two
"keyholes" on the bottom of the case
Switch settings
The MA-12 can through different switch settings be adapted to a variety of running conditions. To set the switches,
open the plastic case by placing and turning a screw-driver between top and bottom at the rear of the case.
DANGER! DO NOT OPEN CONNECTED UNIT
LINE
CONNECTION
V.24/RS-232-C
CONNECTION
12345
S2
S1
Selection of signal activating
transmitter (carrier)
Selection of signal controlling CTS
S2
Selection of power supply 115/230V AC
S1
ON
1 - - 9 OFF
S1
1 2
3 4 5
Transmitter (carrier)
6
activated by
X
XX
X X
X
X
X
X
X
X
X
X
X
Always active
7 8
DCD
RFR
RTS
DTR and RFR
X
Always high
X
SRS
X
DTR and RTS
= Switch ON
= Switch OFF
DTR and SRS
X
RTS
X
DTR and AUX
X
CTS
Controlled
by
9
X
AUX
DTR
X
S1
*
= Factory settings
Connections
Line connection
(5-Position screw-terminal)
Terminal connection (DCE)
(RS-232-C/V.24/V.28, 25-Position D-sub, female)
Direction
No.
Description
Direction 1)
Pin
no.
CCITT V.24
Circuit number
Receiver
Receiver
Transmitter
Transmitter
1
2
3
4
5
R+
RT+
TShield
I
O
I
O
O
O
I
I
I
I
2
3
4
5
6
7
8
11
19
20
25
103
104
105
106
107
102
109
120
108/2
133
Description
TD/Transmitted Data
RD/Received Data
RTS/Request To Send
CTS/Clear To Send
DSR/Data Set Ready
SG/Signal Ground
DCD/Data Carrier Detect
AUX/Auxiliary
SRS/Secondary Request To Send
DTR/Data Terminal Ready
RFR/Ready For Receiving
1) I=Input O=Output on MA-12
Line connection
MA-12
1
R+
Receiver
2
R3
T+
Transmitter
4
TShield 1) 5
Twisted pairs
i.e MA-12, MA-19 ...
T+ Transmitter
TR+ Receiver
R-
1) If shielded cable is used, connect the shield only at one end to avoid ground currents.
Transmission range (interface 2)
Transmission rate bit/s
Cable
42pF/m
0.3mm2
600
1200
2400
4800
9600
19200
38400
18000m
12000m
8000m
5000m
2500m
1000m
500m
MA-12 DC
Specifications
Power supply:
12-36V DC
Power consumption:
Max 3W
Insulation:
1000V
Fuse F1:
1.6A fast 5x20mm
All other specifications according to MA-12 AC
Switch settings
According to MA-12 AC
Connections
According to MA-12 AC, except power supply
Connection
no
Power
Supply
1
2
3
+Voltage
- Voltage
POWER
12-36VDC
LINE
CONNECTION
123
12345
V.24/RS-232-C
CONNECTION
Block diagram
V.24/RS-232
Line
2)
X3
DTR
20
+12V
AUX
11
SRS
19
RFR
25
RTS
CTS
DCD
RD
1
2
&
3
4
5
6
4
5
RTS
7
8
9
+12V
8
1
3
RD
TD
+12V
S1
2
DCD
2
3
4
TD
0V
DSR
SG
PG
+12V
6
7
5
R+
R-
T+
TShield
PWR
0V
1) J2
1
J1
PE
F1
+12V
0V
-12V
Volt
Power supply
sel
Insulated power supply
115/
230V
1) 0 resistor J2 is normally not mounted.
2) Metal housing on D-sub is connected to 0V
Westermo Teleindustri AB har återförsäljare i följande länder, kontakta oss för mer
information.
Westermo Teleindustri AB have distributors in following countries, contact us for further
information.
Norway
Austria
Netherlands
Great Britain
Finland
Belgium
Switzerland
Italy
Denmark
France
Germany
Westermo Teleindustri AB, S-640 40 Stora Sundby, Sweden, Phone +46 16 612 00, Fax +46 16 611 80
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement