- No category
advertisement
Model RTR®
Recordall® Transmitter Register
IDENTIFICATION
The Badger Meter RECORDALL ® Transmitter Register (RTR) is available for all remote and pit settings where a Badger Meter water meter can be located. The RTR is permanently sealed to eliminate moisture, dirt, and other contaminants to insure reliable operation in submerged or indoor applications. As the foundation for Badger Meter's MRT products, including
TRACE ® , Itron ® ERT ® , ORION ® and other Badger ® approved AMR solutions, the RTR provides a digital output for superior electronic resolution.
Available for all RECORDALL Disc, Turbo, Compound and Fire Service
Meters, each RTR is clearly identified on the face of the dial with an assembly number, unit of measure, and meter model (see figure 1.)
Your RTR will either have a factory installed two-conductor cable (black) or a factory installed three-conductor cable (brown) for connection to an AMR module.
If the wire is cut or broken on either a 2 or 3 wire RTR and requires a field splice after initial installation, connect like color wires to maintain proper installation.
To connect to an AMR module, strip approximately 1½” of outer insulation sheath from the RTR and AMR module cables using the 59989-001
Coax Stripping Tool. Use caution in removing the outer sheath so that the inner signal wire insulation is not damaged.
Unwind the outer foil shield from the RTR cable and cut it off even with the outer sheath using the wire cutting pliers. For two conductor cables, do not cut the uninsulated shield drain wire.
RTR with two wires (black cable)
Connect the RTR cable conductors to the AMR module wires using gel-filled connectors, P/N 59761-001, provided in the installation kit.
Crimp the cables completely using a parallel jaw crimper such as Badger
Meter P/N 59983-001. Polarity must be observed when connecting the
RTR to the remote module. Badger Meter, Inc. wiring standards use the black conductor as the negative (-) conductor and the red as the positive (+) conductor.
Figure 1. Identification
REQUIRED MATERIAL
62084-001 RTR Splice Kit
Contents: (3) 59761-001 Gel-Connectors
(2) 34776-001 Cable Ties
(1) 62085-001 Splice Enclosure
OPTIONAL MATERIAL
62440-001 Reel of Belden #8451 2-conductor wire (2000')
64153-001 Reel of Belden #9770 3-conductor wire (1000')
SUGGESTED TOOLS
59983-001 Gel-Splice Crimping Tool
59989-001 Coax Stripper
59991-001 Wire Cutting Pliers
59993-001 Wire Stripper
TORX ® Driver
59987-001 VOM Multimeter (Analog) (OPTIONAL)
Before proceeding with installation, be certain that the meter type and size correspond, and that the proper RTR configuration has been supplied for the application.
CONNECTING RTR
BLACK
RED
Figure 2. 2 Conductor RTR Splice Diagram
Uninsulated
Wire
RTR TRACE DIALOG
Pit/Remote Pit/Remote
ACCESSplus Itron
Red Red Red Red Red
Black Black Black Black Black
® Pit*
Uninsulated Don’t connect Uninsulated Uninsulated
*For field splice information please refer to Itron Pit ERT ® Modules
40W-1 and 50W-1.
Place the two plastic cable ties P/N 34776-001 on wires and tighten securely for strain relief. Remove excess cable tie with wire cutting device.
GEL-SPLICE
CABLE TIES
(Remove Excess)
The RTR should only be connected to a Badger Meter approved product.
Connection to an unapproved product will void the RTR warranty.
RTR-I-05-EN (1-12)
62935-002 Rev. 6
Figure 3. Strain Relief Diagram
Installation Data
RTR ® with three wires (brown cable)
For connection to ORION ® Transmitter, Hexagram ® Star Module or RA-
MAR ® V4 Transpondit, verify the RTR has a brown cable and contains a label with either an 'HE' for connectivity to Hexagram or an 'RA' for connectivity to RAMAR. Using the chart below, connect the RTR conductors to the AMR module conductors using insulation displacement gel-filled splices, P/N 59761-001 provided in the installation kit. Crimp the cables completely using a parallel jaw crimper, P/N 59983-001.
For connection to an Itron ® remote ERT ® , verify that the RTR has a brown cable and contains an 'IT' on the label. For more information on the installation instructions for the Itron remote ERT, please refer to Itron's
Installation Remote ERT Modules 40W-1 and 50W-1.
PIT INSTALLATIONS
Insert the entire splice assembly into the filled splice tube P/N 62085-
001 as indicated in Figure 6. Close the cover with leads exiting alternate sides as indicated in the drawing.
Figure 4. 3 Conductor RTR Splice Installation Diagram
Hexagram
RTR ORION Ramar V4 Pit/Remote Remote
Red Red Wire Red Red
If the wire is cut or broken and requires a field splice after initial installation, connect like colors to maintain proper installation.
Place the two plastic cable ties P/N 34776-001 on wires and tighten securely for strain relief. Remove excess cable tie with wire cutting device.
GEL-SPLICE
CABLE TIES
(Remove Excess)
Figure 6. Splice Enclosure Assembly
TESTING
After connections are complete, test the entire installation including the
RTR, wiring, and remote or pit module for proper operation in accordance with the instructions supplied with the module.
Install the RTR on the water meter and secure it using the TORX ® screw provided.
TROUBLE SHOOTING
An analog ohm meter will show an "open" reading when connected across the OUTPUT leads of the RTR. When operating the RTR, the ohm meter should show a momentary deflection toward zero when the
RTR sends a signal.
Figure 5. Splice Installation Diagram
TRACE ® is a registered trademark of American Meter Company. Badger ® , Recordall ® , ORION ® , and RTR ® are registered trademarks of Badger Meter, Inc. Itron trademarks of Itron, Inc. TORX
Hexagram ®
®
is a trademark of Hexagram, Inc. RAMAR ®
® and ERT ® are registered
is a Registered trademark of Camcar, Division of Textron, Inc.
is a trademark of RAMAR Technology.
Other trademarks appearing in this document are the property of their respective entities.
© 2012 Badger Meter, Inc. All rights reserved.
Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists.
Badger Meter
| P.O. Box 245036, Milwaukee, Wisconsin 53224-9536
800-876-3837 | [email protected] | www.badgermeter.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project