Master MH-600T-KFA User's Manual & Operating Instructions

Add to My manuals
16 Pages

advertisement

Master MH-600T-KFA User's Manual & Operating Instructions | Manualzz

User’s Manual & Operating Instructions

Model Number

HH-600T-KFA

Consumer: Please Read These Instructions And Keep For Your Reference

DANGER

GENERAL HAZARD WARNING:

Be sure to comply with the instructions and warnings provided with this heater, or death, serious bodily injury and property loss, damage from the hazards of fire, explosion, burn,

Only persons who can follow and understand these instructions should use or service this the manufacturer.

DANGER

Not for use in residential living areas or in non-adequately ventilated enclosed spaces.

For outdoor use. Indoor use permitted for: The temporary heating of adequately ventilated buildings or structures under construction, alteration or repair.

© 2014 Pinnacle Products International, Inc.

668 Stony Hill Road #302 Yardley, PA 19067 USA Toll Free: (800) 641-6996

Fax: (215) 891-8461 • Web: www.remingtonheater.com • Email: [email protected]

701000307-14

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Table of Contents

Safety Information .......................................... 2-3

Unpacking .......................................................... 3

Features ............................................................ 3

Assembly ........................................................ 4-5

Operation ........................................................ 6-8

Fuels .................................................................. 6

Theory of Operation ........................................... 6

Ventilation .......................................................... 6

Long Term Storage ............................................. 8

Maintenance ................................................. 9-11

Wiring Diagram ................................................ 11

Exploded View ................................................. 12

Replacement Parts .......................................... 13

Troubleshooting .......................................... 14-15

Warranty ............................................ Back Cover

Safety Information

WARNING

Fire, burn, inhalation, and explosion hazard.

Keep combustibles, such as building materials, paper or cardboard, a safe distance away from the heater as recommended by these instructions. Never use the heater in spaces which contain products such as gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles, or any unknown chemicals. This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to VENTILATION on Page 7.

WARNING

Do not operate this heater until you have read, and thoroughly understand these safety and operating instruction. Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, property loss or damage from the hazards of fire, soot production, explosion, burns, asphyxiation or carbon monoxide poisoning. Only persons who can read and understand these instructions should use or service this heater.

Not for use in homes or recreational vehicles.

California Residents:

Combustion by-products produced when using this product contain carbon monoxide, a chemical known to the state of California to cause cancer and birth defects (or other reproductive harm).

Massachusetts Residents:

Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation. Use of this heating device in Massachusetts requires local fire department permit (M.G.L.C.

148, Section 10A).

New York City Residents:

The New York City Fire

Code prohibits the storage, handling and use of kerosene fueled heaters for space heating. Any person violating that provision may be punished by a fine up to $10,000 and a term of imprisonment up to 6 months.

DANGER

Indicates an im minen tly hazardous situation which, if not avoided, WILL result in death or serious injury.

WARNING

CAUTION

Indicates a poten tially hazardous situation which, if not avoided,

COULD result in death or serious injury.

Indicates a poten tially hazardous situa tion which, if not avoided, MAY result in minor or moderate injury.

This is a kerosene, direct-fired, forced air heater. It is primarily intended for use for temporary heating of buildings under construction, alteration or repair. Direct-fired means that all of the combustion products of the heater enter the heated space. This appliance is rated at 98% combustion efficiency, but does produce small amounts of carbon monoxide. Carbon monoxide is toxic.

DANGER Carbon Monoxide poisoning may lead to death!

Humans can tolerate small amounts of carbon monoxide, and precautions should be taken to provide proper ventilation. Failure to provide proper ventilation according to this manual can result in death. Early signs of carbon monoxide poisoning resemble the flu.

Symptoms of improper ventilation are:

* headache * dizziness * burning of the nose and eyes

* nausea * dry mouth * sore throat that 1-K kero sene be used. 1-K kerosene has been refined to virtually eliminate contami nants, such as sulfur, which can cause a rotten egg odor during the operation of the heater. However, #1 or

#2 fuel oil (diesel fuel) may also be used if 1-K kero sene is not available. Be advised that these fuels do not burn as clean as 1-K kerosene, and care should be taken to provide more fresh air ventilation to accommodate any added contaminants that may be added to the heated space. Use of #1 or #2 fuel oil may result in more periodic maintenance.

WARNING

Risk of indoor air pollution!

- Use this heater only in well ventilated areas! Provide at least a three square foot (2,800 sq cm) opening of outside air for every

100,000 BTU/hr of heater rating.

- People with breathing problems should consult a physician before using the heater.

- Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble flu-like symptoms such as headaches, dizziness, and/or nausea. If you have these symptoms, your heater may not be working properly.

© 2014 Pinnacle Products International, Inc.

2

Kerosene User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Safety Information (continued)

Simply locate fan in safe, desired position on level ground, and connect to approved power source.

- Get fresh air at once! Have the heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, those with heart or lung problems, anemia, or those under the influence of alcohol, or at high altitudes.

WARNING

Risk of burns / fire / explosion!

- NEVER use fuels such as gasoline, benzene, paint thinners, or other oil compounds in this heater (RISK OF FIRE OR

EXPLOSION).

- NEVER refill the heater’s fuel tank while heater is operating or still hot. This heater is EXTREMELY HOT while in operation.

- Keep all combustible materials away from this heater.

- NEVER block air inlet (rear) or air outlet (front) of heater.

- NEVER use duct work in front or at rear of heater.

- NEVER move or handle heater while still hot.

- NEVER transport heater with fuel in its tank.

- If equipped with a thermostat, the heater may start at any time.

- ALWAYS locate heater on a stable and level surface.

- ALWAYS keep children and animals away from heater.

- Bulk fuel storage should be a minimum of 25 ft. from heaters, torches, portable generators, or other sources of ignition. All fuel storage should be in accordance with federal, state, or local authorities having jurisdiction.

- Never use this heater in living or sleeping areas.

- NEVER use this heater where flam mable vapors may be present.

WARNING Risk of electric shock!

- Use only the electrical power (voltage and frequency) specified on the model plate of the heater. Use only a three- prong, grounded outlet and extension cord.

- ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water, or wind.

- ALWAYS unplug the heater when not in use.

Minimum clearance from Combustibles:

Front

Top, Sides and Rear

10 ft

4 ft.

Unpacking

Remove the heater and all of the packaging materials from the shipping carton.

NOTE: Save the box and packaging materials for future storage.

Check the chart below to be sure that you have all of the parts required to assembly your heater. If you find that any parts are missing, call 215-891-8460 for assistance in receiving the missing components.

Features

Front Shell

Front Handle

Handle Frame

Rear Shell

Rear Handle

Lower Shell

Fan Guard

Control Panel

Figure 1: Features of HH-600T-KFA

© 2014 Pinnacle Products International, Inc.

3

Fuel Tank

Power Cord

Kerosene User’s Manual

Front Handle

Assembly

Handle Frame

Screw (L)

Cord Wrap

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Fuel Tank Flange

Nut

Wheel Support Frame

Wheel (Pneumatic)

Flat Washer (L)

Cotter Pin

Wheel Cap

Figure 2: Features of HH-600T-KFA

Flat Washer (S)

Axle

Bushing

Rear Handle

Screw (S)

Fan Guard

Wheel Tube Valve

© 2014 Pinnacle Products International, Inc.

4

Kerosene User’s Manual

Wheels

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Wheel support frame

Wheels and Axle

Wheel Caps

Front and Rear Handle

Cord Wraps

Handle Frame

Screws, Nuts and Washers

Cotter Pins and Bushings

Assembly (Continued)

Front Handle

HH-600T-KFA

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Handle Frame

Bushings

Rear Handle

Screws (L)

Screws (S)

Flat Washers (S) Flat Washers (L)

Cotter Pins Bushings

Wheel Support Frame

Nuts Cord Wraps

Figure 3: Hardware Components

Axle

HH-600T-KFA

- Tools required: Medium phillips screw driver, open end or adjustable wrench, needle nose pliers.

ASSEMBLING FRAME AND WHEELS

1. Slide axle through wheel support frame. Install wheel bushings, flat washers (S) and wheel on axle.

NOTE: When installing wheels, tube valve should face out from support frame (Figure 2).

2. Place flat washers (L) and cotter pins on axle ends and bend cotter pins with long nose pliers to secure.

© 2014 Pinnacle Products International, Inc.

5

3. Place wheel cap on flat washers (L) and put wheel cap in flat washers (L) end.

4. Place heater on wheel support frame. Make sure air inlet end

(rear) of heater is over wheels. Align the holes on fuel tank flange. Insert screws through handles (front and rear), fuel tank flange, and wheel support frame as shown in Figure 3 and attach nut finger tight after each screw is inserted.

5. After all screws are inserted, tighten nuts firmly.

CAUTION

TO TANK.

DO NOT OPERATE HEATER WITHOUT

SUPPORT FRAME FULLY ASSEMBLED

Kerosene User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Operation

KEROSENE (1-K)

For optimal performance of this heater, it is strongly suggested that 1-K kero sene be used. 1-K kerosene has been refined to virtually eliminate contami nants, such as sulfur, which can cause a rotten egg odor during the operation of the heater. However, #1 or

#2 fuel oil (diesel fuel) may also be used if 1-K kerosene is not available. Be advised that these fuels do not burn as clean as 1-K kerosene, and care should be taken to provide more fresh air ventilation to accommodate any added contaminants that may be added to the heated space. Using diesel fuel can cause excess

soot production. DO NOT use any fuel that is not approved above.

NOTE: Kerosene should only be stored in a blue container that is clearly marked “kerosene”. Never store kerosene in a red container. Red containers are associated with gasoline.

- NEVER store kerosene in the living space. Kerosene should be stored in a well ventilated area outside the living area.

- NEVER use fuel such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners or other oil compounds in this heater (THESE ARE VOLATILE FUELS THAT CAN CAUSE A

FIRE OR EXPLOSION).

- NEVER store kerosene in direct sunlight or near a source of heat.

- NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time. OLD KEROSENE

WILL NOT BURN PROPERLY IN THIS HEATER.

- Use 1-K kerosene in this heater. #1 fuel is a suitable substitute.

THEORY OF OPERATION

Fuel System: This heater is equipped with a fuel pump that forces fuel through the fuel line connected to the fuel intake, and then through a nozzle in the burner head. This fuel is then sprayed into the combustion chamber in a fine mist.

Quick-Fire Ignition: The electronic ignitor sends voltage to a specially designed spark plug. The spark plug ignites the fuel and air mixture.

Air System: The heavy duty motor turns a fan that forces air into and around the combustion chamber. Here, the air is heated and then forced out the front of the heater.

Temperature Limit Control: This heater is equipped with a

Tempera ture Limit Control designed to turn the heater off should the internal temperature rise to an unsafe level. If this device activates and turns your heater off, it may require service.

Once the temperature falls below the reset temperature, you will be able to start your heater.

Electrical System Protection: This heater’s electrical system is protected by a fuse that protects it and other electrical components from damage. Fuse is located inside of an in-line “FUSE

BARREL”. If your heater fails to operate, check this fuse first and replace as needed.

Flame Sensor: Utilizes a photocell to monitor the flame in burn chamber during normal operation. It will cause the heater to shut off should the burner flame extinguish.

FUELING THE HEATER

It is always a good idea to fire the heater outdoors for the first time. This will allow any oils used in the manufacturing process to be burned off in a safe environment. This initial burn should last at least 10 minutes.

WARNING

NEVER REFUEL THIS HEATER WHILE IT

IS HOT OR OPERATING. FIRE OR

EXPLOSION COULD RESULT.

CAUTION

NEVER FILL THE FUEL TANK INDOORS.

ALWAYS FILL THE TANK OUTDOORS.

BE SURE THAT THE HEATER IS ON LEVEL GROUND WHEN

FUELING, AND NEVER OVERFILL THE FUEL TANK.

VENTILATION

CAUTION

Risk of indoor air pollution. Use heater only in well ventilated areas.

Always provide a fresh air opening in the heated space of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr.

of heater output. Provide a larger opening if more heaters are being used.

TO START HEATER

1. Fill fuel tank with 1-K kerosene or No. 1 fuel oil.

2. Attach fuel cap and be sure it is secure.

3. Plug power cord into three prong, grounded extension cord and plug extension cord into three prong 120V grounded outlet. The extension cord should be at least six feet long.

Extension Cord Wire Size Requirements:

• 6 to 10 feet long, use 14 AWG conductor.

• 101 to 200 feet long, use 12 AWG conductor.

• 201 to 300 feet long, use 10 AWG conductor.

• 301 to 400 feet long, use 8 AWG conductor.

• 401 to 500 feet long, use 6 AWG conductor.

4. Push “OPERATION BUTTON”. Power indicator lamp and room temperature display will light and heater will start. Push the up and down arrow keys on the control panel to adjust the thermostat setting.

© 2014 Pinnacle Products International, Inc.

6

Kerosene User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Operation (Continued)

Combustion Chamber

Room temperature

Power Lamp

Fan

Motor

Fuse Barrel

Fuse

MODEL

Internal Shut-Off

Temp. +/-10

Degrees

HH-600T-KFA

176°F / 80°C

Fuel Tank Control Panel

Operation Button

Figure 4: Overview of Heater design

If heater does not start, the thermo stat setting may be too low.

Push “TEMP CONTROL UP ARROW” to higher setting to start heater. If heater still does not start, see Troubleshooting Chart on page 14.

NOTE: The major electrical components of this heater are protected by a circuit breaker (fuse) mounted to the power switch. If your heater fails to start, check this first and replace as necessary. You should also check your power source to insure that proper voltage and frequency are being supplied to the heater.

Reset Temp.

+/-10 Degrees

149°F / 65°C

3. To temporarily stop heater, set thermostat at a temperature lower than air around heater. Heater will cycle back on if air temperature around heater matches thermostat setting.

TO RESTART THE HEATER

CAUTION

Do not restart heater until cooling cycle is finished.

1. Wait until after cooling cycle has finished after stopping heater.

2. Repeat steps under TO START HEATER.

TO STOP HEATER

WARNING

Never unplug heater while heater is running!

Heater must go through cooling cycle. The cooling cycle cools the combustion chamber. Damage to heater can occur if combustion chamber is not cooled. Do not restart heater until cooling cycle is complete.

1. Push “OPERATION BUTTON”, This will cause heater flame to go out. The motor will continue to run during the cooling cycle.

This allows the fan to cool the combustion chamber. When the cooling cycle (approx. 2 minutes) is finished, the motor will stop.

Do not unplug heater until cooling cycle is finished.

2. Disconnect heater from power source.

ELECTRICAL OUTLET

WARNING

Shock Hazard!

- Never plug in an appliance with more than 5amp rating in this outlet.

- Always keep outlet covered when not in use

- 120V 5amp max (non fused).

Electrical Outlet

120v 5 amp max

(non-fused)

Operation Button

Temp Control Buttons

Figure 5: Control Panel

© 2014 Pinnacle Products International, Inc.

7

Figure 6: Electrical Outlet

Kerosene User’s Manual

Operation (Continued)

LONG TERM STORAGE

Drain Fuel Tank

1. Remove drain nut from rear bottom side of fuel tank by unscrewing nut and drain. See Figure 7.

2. Using a small amount of kerosene, swirl and rinse the inside of the tank.

NEVER MIX WATER WITH KEROSENE, as it will cause rust inside the tank. Pour the kerosene out, making sure that you remove it all.

IMPORTANT: Do not store kerosene over summer for use during next heating season. Using old fuel may damage heater.

Drain Bolt

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

IMPORTANT: Never store leftover kerosene over the summer.

Using old fuel can damage your heater.

Drain Bolt

Figure 7: Drain Bolt

Drain Nut

3.Reinstall drain bolt as follows:

- Insert bolt’s seal head fully into drain hole so that flange is flush to tank’s bottom.

- Insert seal cap fully into head hole so that cap flange is flush to head flange.

IMPORTANT: Reinstall bolt fully into hole in tank; otherwise it will not seal completely.

- Make sure storage place is free of dust and corrosive fumes.

- Store the heater in the original box with the original packing material and keep USER'S MANUAL with heater.

Drain Bolt

Figure 8: Drain Bolt Reinstall

© 2014 Pinnacle Products International, Inc.

8

Kerosene User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Maintenance

WARNING

Never service heater while it is plugged in or while hot!

Use only original equipment replacement parts. The use of alternate or third party components can cause unsafe operating conditions, and will void your warranty.

We suggest following a maintenance schedule as follows:

FUEL/FUEL TANK:

Flush every 200 hours of operation or as needed. Do not use water to flush the tank. Use fresh 1-K kerosene only.

AIR FILTERS:

The Air Intake Filter should be replaced or washed with soap and water and dried thoroughly every 500 hours of operation, or less, depending on conditions.

The Output and Lint Filters should be replaced every 500 hours of operation or less, depending on conditions.

NOTE: Use of diesel may require additional maintenance.

FAN BLADES:

CLEAN EVERY SEASON OR AS NEEDED.

- Remove upper shell (See air intake filter).

- Use Allen wrench to loosen set screw which holds fan blade to motor shaft.

- Slip fan blade off motor shaft.

- Clean fan blade using soft cloth moistened with kerosene or solvent.

- Dry fan blade thoroughly.

- Reinstall fan blade to motor shaft.

- Place fan hub flush with end of motor shaft.

- Place set screw on flat end of shaft.

- Tighten screw firmly (40-50 inch pounds/ 4.5-5.6 N-m). Reinstall upper shell.

Figure 9: Nozzle Replacement

Nozzle

Nozzle

- Reinstall nozzle into burner head and tighten firmly (175-200 inch-pounds).

- Reinstall spark plug in burner head.

- Attach burner head to combustion chamber.

- Attach spark plug wire to spark plug

- Attach fuel line to burner head and tighten firmly.

- Replace upper shell.

- Attach ignitor wire to spark plug.

- Attach fuel and air line hoses to burner head.

- Reinstall fan blade and upper shell.

Spark Plug

NOZZLE:

Remove dirt in nozzle as needed

- Remove upper shell.

- Remove fuel line B from burner assembly by using wrench.

- Remove burner head from burner assembly.

- Remove lead wire from spark plug.

- Remove spark plug from burner head.

- Carefully remove nozzle from burner head using socket wrench.

- Blow compressed air through face of nozzle (This will remove any dirt).

- Inspect nozzle for damage. If damaged or clogged, replace nozzle.

- Make sure plug is in place on burner head.

Figure 10: Spark Plug Replacement

SPARK PLUG:

CLEAN AND REGAP EVERY 600 HOURS OF OPERATION OR

REPLACE AS NEEDED.

- Remove upper shell.

- Remove spark plug wire from spark plug.

- Remove spark plug from burner head using medium Phillips screwdriver.

- Clean and regap spark plug electrodes to 0.1” (2.5 mm) gap.

- Reinstall spark plug into burner head.

- Attach spark plug wire to spark plug.

- Reinstall upper shell.

© 2014 Pinnacle Products International, Inc.

9

Kerosene User’s Manual

Maintenance (Continued)

Burner Assembly

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Fuel Filter

Fuel Cover

Photocell

Figure 12: Removing Fuel Filter

Figure 11: Photocell

PHOTOCELL:

CLEAN PHOTOCELL ANNUALLY OR AS NEEDED.

- Remove upper shell.

- Remove fan (See fan blades on page 9).

- Remove photocell from its mounting bracket

- Clean photocell lens with cotton swab.

TO REPLACE: Remove side cover near Operation switch.

- Disconnect wires from Operation switch and remove photocell.

- Disconnect wires from circuit board and remove side cover.

- Install new photocell and attach wires to circuit board.

- Replace switch wires to operation switch and side cover.

- Replace fan and upper shell.

Fuel Cap

Fuel Gasket

Fuel Filter A

FUEL FILTER:

CLEAN TWICE PER HEATING SEASON OR AS NEEDED.

- Open rear shell.

- Remove filter cover by unscrewing four screws (see Figure 12).

- Remove fuel filter from filter cover.

- Wash fuel filter in clean kerosene.

- Replace fuel filter and filter cover.

Fuel filter A in fuel tank:

- Remove fuel cap (see Figure 13).

- Take out fuel filter from fuel tank.

- Wash fuel filter A with clean kerosene.

- Replace fuel filter in fuel tank.

- Replace fuel cap on fuel tank.

© 2014 Pinnacle Products International, Inc.

10

Figure 13: Fuel Filter A in Tank

PUMP PRESSURE ADJUSTMENT:

- Remove rear shell.

- Remove fuel line A from fuel pump by using wrench.

- Replace pressure gauge at outlet of fuel pump.

- Adjust pump pressure by turning pressure adjustment screw

- Replace pressure gauge at outlet of fuel pump.

- Adjust pump pressure by turning pressure adjustment screw.

- Turn relief valve clockwise to increase pressure.

- Turn relief valve counterclockwise to decrease pressure.

- Set pump pressure to 128 PSI by turning screwdriver.

Pump pressure gauge is not supplied.

Kerosene User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Maintenance (Continued)

NOTE: Use only original equipment replacement parts. Use of alternate or third party components will void any warranty and may cause unsafe operating conditions.

- Stop heater (See OPERATION, page 6).

- If accessory pressure gauge is being used, remove pressure gauge.

- Replace pressure gauge, and plug in end of filter cover.

NOTE: If heater does not ignite when heater is turned on, please turn AIR VENT SCREW counter clockwise to release air, then turn OPERATION SWITCH back on.

Pump Adjusting

Screw

Figure 14: Pump Pressure Adjustment

Wiring Diagram

Figure 15: Wiring Diagram for HH-600T-KFA

© 2014 Pinnacle Products International, Inc.

11

Kerosene User’s Manual

Exploded View

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Figure 16: Exploded View for HH-600T-KFA

© 2014 Pinnacle Products International, Inc.

12

Kerosene User’s Manual

Item # Description

1 Upper Front Shell

2 Upper Rear Shell

3 Lower Shell

4 Cord Bushing

5 Fuel Tank

6 Right Side Cover

7 PCB Case

8 PCB Assembly

9 PCB Lead Wire

10 Drain Plug

11 Fuel Cap Assembly

12 Fuel Filling Filter

13 Fuel Gauge

14 Fuel Line

15 Fuel Filter Cover Screw

16 Fuel Filter Cover

17 Fuel Filter

18 Drain Line

19 Ignitor

20 Combustion Chamber

21 Power Cord

22 Wheel Support Frame

23 Wheel Axle

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Parts List

HH-600T-KFA

70-033-0200

70-008-0610

70-027-0801

70-027-0800

70-027-0802

70-002-0107

70-006-0200

70-006-0300

75-007-0400

70-036-1000

70-006-0502

70-006-0503

70-006-0501

70-036-1001

70-037-0800

70-034-0300

70-064-0200

70-041-0403

Item #

24 Wheel

Description

25 Cotter Pin

26 Wheel Bushing

27 Flat Washer

28 Wheel Cap

29 Safety Guard

30 Socket Cover

31 Electric Outlet Assembly

32 Thermostat

33 Thermostat Bracket

34 Photocell

35 Burner Head

36 Spark Plug

37 Nozzle

38 Burner Motor

39 Fan Fixing Screw

40 Fan Assembly

41 Fan Motor Assembly

42 Motor Supporter

43 Front Handle

44 Handle Frame

45 Rear Handle

46 Cord Wrap

HH-600T-KFA

70-041-0113

70-041-0107

70-041-0109

70-041-0105

70-041-0111

70-065-0200

70-030-0100

70-029-0100

70-019-0500

70-019-0501

70-016-0160

70-014-0800

70-052-0500

70-015-0800

70-063-0201

70-024-0805

70-024-0800

70-021-0800

70-020-0408

70-042-0400

70-042-0401

70-043-0400

70-032-0200

© 2014 Pinnacle Products International, Inc.

13

Kerosene User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Symptom

Troubleshooting

Possible Cause(s) Solution

E1

Heater will not ignite, but motor runs for a short period of time (Lamp is flickering)

E1

Fan does not turn when heater is plugged in.

E1 or E2

1. Wrong pump pressure

2. Dirty fuel filter

3. Dirt in nozzle

4. Dirty photocell lens

5. Photocell assembly not properly installed

(not seeing flame)

6. Bad electrical connection between photocell and Main PCB assembly

7. Defective photocell

1. No fuel in tank

2. Wrong pump pressure

3. Carbon deposits on spark plug and/or improper gap

4. Dirty fuel filter

5. Dirt in nozzle

6. Water in fuel tank

7. Bad electrical connection between ignitor and Main PCB assembly

8. Ignitor Wire not attached to spark plug

9. Defective ignitor

1. Thermostat setting too low

2. Poor electrical connection between motor and Main PCB assembly

1. See Pump Pressure Adjustment, Page 10

2. See Fuel Filter, Page 10

3. See Nozzle, Page 9

4. Clean Photocell Lens, Page 9

5. Make sure photocell boot is properly seated in bracket (See page 10)

6. Check electrical components (See Wiring

Diagrams, Page 11)

7. Replace Photocell, Page 10

1. Fill tank with kerosene

2. See Pump Pressure Adjustment, Page 10

3. See Spark Plug, Page 9

4. See Fuel Filter, Page 10

5. See Nozzle, Page 9

6. Flush fuel tank with clean kerosene, page 7

7. Check electrical connections (See Wiring

Diagrams, Page 11)

8. Attach ignitor wire to spark plug (See Spark Plug,

Page 9)

9. Replace ignitor

1. Adjust thermostat to a higher setting

2. Check electrical connections (See Wiring

Diagrams, Page 11)

E3

1. Switch Failure

2. Short Circuit

1. Replace Switch

2. Check Wiring and connection

© 2014 Pinnacle Products International, Inc.

14

Kerosene User’s Manual

Symptom

E4

E5

Other Problems

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Troubleshooting (Continued)

Possible Cause(s)

Sensor disconnected

Solution

A. Check limit control thermostat

Temperature limit safety device is overheated

B. Check sensor connection

1. Wait until unit cools down

1. Poor Combustion

- Flames extending beyond heater

- Low heat output

2. Power Failure

- No power supply to heater

1. Poor Combustion

- Adjust Pump Pressure (see page 10)

2. Power Failure

- Check / Replace Fuse

© 2014 Pinnacle Products International, Inc.

15

Kerosene User’s Manual

LIMITED WARRANTY

Pinnacle Products International, Inc. warrants this heater to the original retail purchaser only, to be free from defects in material and workmanship for a period of one

(1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided.

Pinnacle Products International, Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your sales slip, invoice, or cancelled check from the original purchase. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the warranty period, and which Pinnacle Products International, Inc. shall determine at its reasonable discretion.

This warranty does not apply to products purchased for rental use.

This Limited Warranty does not cover any failures or operating difficulties due to normal wear and tear, accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance and service by you or any third party. Failure to perform normal and routine maintenance on the heater, shipping damage, damage related to insects, birds, or animals of any kind, and damage due to weather conditions are also not covered. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.

All transportation costs for the return of the damaged product or parts will be the responsibility of the purchaser.

Upon receipt of damaged item, Pinnacle Products

International, Inc. will examine the item and determine if defective. Pinnacle Products International, Inc. will repair or replace and return the item, freight pre-paid. If

Pinnacle Products International, Inc. finds the item to be in normal operating condition, or not defective, the item will be returned freight collect.This Limited Warranty is in lieu of all other express warranties. Pinnacle

Products International, Inc. disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors.

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS

WARRANTY EXPIRES, Pinnacle Products International,

Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES,

INCLUDING WITHOUT LIMITATION THE IMPLIED

WARRANTIES OF MERCHANTABILITY AND FITNESS

FOR A PARTICULAR APPLICATION. FURTHER,

Pinnacle Products International, Inc. SHALL HAVE NO

LIABILITY WHATSOEVER TO PURCHASER OR ANY

THIRD PARTY FOR ANY SPECIAL, INDIRECT,

PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL

DAMAGES. Pinnacle Products International, Inc.

assumes no responsibility for any defects caused by third parties. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you.

Pinnacle Products International, Inc. does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on

Pinnacle Products International, Inc.

Always be sure to specify model number and serial number when making any claim with Pinnacle Products

International, Inc. For your convenience use the space provided below to list this information:

Model #: ____________________

Serial #: _________________________

Date of Purchase: _________________

advertisement

Related manuals

Download PDF

advertisement