Victron Datasheet Blue Power Battery Charger IP20 -12-25-and-24-12

Victron Datasheet Blue Power Battery Charger IP20 -12-25-and-24-12
Blue Power Battery Charger GX IP 20: 12/25 and 24/12
www.victronenergy.com
180-265 VAC
Adaptive 4-stage charge characteristic: bulk – absorption – float – storage
The Blue Power charger features a microprocessor controlled ‘adaptive’ battery management. The ‘adaptive’
feature will automatically optimize the charging process relative to the way the battery is being used.
Less maintenance and aging when the battery is not in use: the Storage Mode
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the
storage mode float voltage is reduced to 2,2 V/cell (13,2 V for a 12 V battery) to minimize gassing and corrosion
of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery.
This feature prevents stratification of the electrolyte and sulfation, a major cause of early battery failure.
Blue Power Battery Charger
GX IP 20 12/25 (1)
Protected against overheating and silent fan cooling
Output current will reduce as temperature increases up to 60°C, but the Blue Power charger will not fail.
The load and temperature controlled fan is practically inaudible.
Two LED’s for status indication
Yellow LED: bulk charge (blinking fast), absorption (blinking slow), float (solid), storage (off)
Green LED: power on
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free
of charge from Victron Energy and downloadable from www.victronenergy.com).
Blue Power Charger GX IP 20
Input voltage range
12/25 (1)
24/12 (1)
180-265 VAC or 250-350 VDC
180-265 VAC or 250-350 VDC
Frequency
Number of outputs
Charge voltage 'absorption' (V DC)
Charge voltage 'float' (V DC)
Charge voltage 'storage' (V DC)
Charge current (A)
45-65 Hz or DC
1
1
14,4
28,8
14
28
13,2
26,4
25
12 or 15
Charge characteristic
Minimum battery capacity (Ah)
4-stage adaptive
75
45
Can be used as power supply
Protection
Operating temp. range
Yes
Battery reverse polarity (fuse)
Output short circuit
Over temperature
-20 to +60°C (full rated output up to 40°C)
Humidity (non condensing)
Max 95 %
Cooling
Fan assisted
ENCLOSURE
Material & Colour
Battery-connection
Aluminium (blue RAL 5012)
One output: black and red cable of 1,5 meter
Three outputs: screw terminals 6 mm²
230 V AC-connection
Cable of 1,5 meter with CEE 7/7 or AS/NZS 3112 plug
Protection category
IP 20
Weight (kg)
1,3
Dimensions (h x w x d in mm)
66 x 90 x 235
STANDARDS
Safety
EN 60335-1, EN 60335-2-29
Emission
EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: [email protected] | www.victronenergy.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project