SIB | Standalone Keypad Access Control | STAND-ALONE ACCESS CONTROL SYSTEMS

Stand-alone
acceSS control SyStemS
Stand-alone acceSS control SyStemS
om500 KeyPad aUdIt-traIl locKS
taBle oF contentS
Page
OM500 keypad audit-trail locks ......................................2-3
Proximity card reader locks ............................................4-5
Magnetic card reader locks ............................................6-7
Hardware specifications (Mortise)......................................8
Page
Hardware specifications (Cylindrical) ................................9
How to order ..............................................................10-13
Miscellaneous - Finishes ..................................................14
Notes ................................................................................15
OM500 KEYPAD AUDIT-TRAIL LOCKS
The Stanley OMNILOCK stand-alone electronic locksets are built upon the OMNILOCK technology that revolutionized Access
Control with the World’s First battery-controlled locks in the 1980’s. Now, as a strong addition to the Stanley Security Solutions
family, the OMNILOCK stand-alone systems offer the same time-proven features and reputation as the most versatile, rugged,
and reliable access control solution for Industrial, Government, or Institutional applications. OMNILOCK cylindrical locks install
in a standard ANSI 156.2 (formerly 161) door prep and therefore, unlike other products, these locks require NO extra holes to
be drilled in the door.
The Stanley OMNILOCK 500-Series keypad-only locks are programmable at the door by using the WP4000M infrared printer.
System Administrators may easily add or delete keypad codes at the keypad as desired. The OM500 locks record the audit
trail of the last 750 events. Users may be assigned membership in user groups and group access may be controlled by time
schedules. Up to 32 holidays may be pre-programmed in these systems. The 500 series systems may be programmed to lock
or unlock automatically at a certain time, to unlock and remain unlocked after the first valid code is entered, or to lock out certain groups of users at certain times (such as after a 8AM-5PM work shift). Stanley offers the OM500 on the BEST 93K
Grade-1 cylindrical lock chassis and the BEST 45H Grade-1 mortise chassis. The OM500 series of locks is available in cylindrical, mortise, mortise-with deadbolt, wall mount system (controls electrified hardware such as electric strikes, magnetic locks,
elevators, or electrified exit devices), and Quick Adapter configurations.
The BEST 93KOM Cylindrical
OMNILOCK (left) combine the finest USA
Made Grade-1 locksets with time-proven
OMNIlock electronics. At left is a 93KOM7-DV-15-PDV-C-S3-626 proximity
reader lockset. The BEST 45HOM
OMNILOCK Mortise or Mortise-withDeadbolt locks (right) offer unmatched
Grade-1 reliability. Standard or IC Core
cylinders are available (accepts 1-3/8inch to 1-3/4-inch Mortise cylinder
lengths). The Mortise Deadbolt locks are
also available in a Mortise DeadboltLockout (MDL) configuration used at
High-Security DOD or InformationSecurity facilities.
The OMD-WP4000M Printer (right) allows the system administrator
to print out audit reports, view the setup and tailoring of time
Schedules, or modify and assign keypad codes for up to 500 users
per lock. Using the autocode feature, ANY number of Stanley
OMNILOCK’s may be programmed with groups of identical,
randomly-generated keypad codes in seconds. These systems have
been extensively used in the industry for over twenty years!
It is important to note that the OM500 systems may be field-upgraded to the card-reader systems or the Wireless Access Management
System (WAMS). Many of the current WAMS users have “migrated”
their OM500 systems over time, enjoying the fact that they can modify their previously purchased assets in minutes at their own facility!
Please contact us for a local Dealer or for a point-of-reference
among our End Users.
2
Stanley OMNILOCK OM500
keypad-only locks may be
programmed using the OMDWP4000M printer (at left) or
directly at the keypad using
the easy-to-comprehend
Programming Flowchart.
S ta n d - a l o n e a c c e S
SYSTEM REQUIREMENTS
The Stanley OMNILOCK 500-Series Cylindrical, Mortise, Mortise-with-deadbolt, Quick Adapter, Wall Mount System, or Exit
Device trim locks are programmable at the door with the OMD-WP4000M printer or may be programmed directly at the keypad using the logical Programming Flowchart. Therefore, all you need to get started is an OMD-WP4000M printer and any
number of OM500 locks. No awkward plug-in cables or proprietary Data Transfer Modules (DTM) are required to program
these systems.
Exit Device Adapters easily adapt to several
exit device manufacturers, like Precision.
The QAXOM systems installs without drilling
additional holes in the door. (QAXOM-7-15
PDV-G-626-RHR-B shown)
Weatherized locks withstand extreme heat, cold, and humidity (above center).
For certain applications, the stainless steel shroud p/n OMD-12911 (above
right) offers the ideal solution to shield the system(s) from sand, dust, ice, or
freezing rain
ACCESS LEVELS
Unlocked: Free passage-handle unlocked.
Unlocked With Code: Unlocked after ‘first code in’.
Code Required: Valid code required for entry.
Lockout: Sub master or master code required for entry.
Shutdown: Master code required for entry.
Anti-tamper: Initially set after 3 consecutive invalid code
entries. Additional key presses ignored for 10 seconds.
CODE TYPES
All codes are from 4 to 9 digits long as determined by the
length of the master code.
General User Code
Purpose: Allows access when access level is at code required
and user group is enabled.
Quantity: 500 codes for OM500. Codes are assignable into
four user groups.
Service Code
Purpose: Variable lifetime code-allows temporary (time limited)
access to service personnel.
Quantity: 1
Sub-master Code
Purpose: Limited programming and entry code.
Quantity: 8
Master Code
Purpose: Programming, entry code and shutdown.
Quantity: 1
Audit Code
Purpose: Outputs audit log report to WP4000M wireless printer.
Quantity: 1
Audit Log Transactions: Retains last 750 events.
Record Format: Date, time, identity, transaction.
Transaction Types: 16
INTERNAL CLOCK
Resolution: 1 minute with leap year correction.
Daylight Savings: Automatic or manual corrections.
SPECIFICATIONS
TIME SCHEDULE
Sets Access level and/or controls access groups
automatically at preprogrammed times.
Capacity: 144 scheduled events.
User Groups: 4
Holidays: 32
FACILITY AUTOCODE
Muliple locks can be quickly set up with identical access
codes to accommodate any number of users throughout
a campus or builiding complex.
BATTERIES
Type: Four size 'AA' 1.5 Volt Alkaline
Expected Life: 120,000 operations under normal
operating conditions (40 to 80ºF room temperature).
Low Battery Warning: LEDs will flash Green-Red-Red
on each entry to alert users of a low battery condition.
Normal operation will continue for several hundred
entries before entering shutdown level.
Memory Retention: All codes, programming, etc. will be
retained for 1 minute while batteries are being changed.
(changing one battery at a time is recommended).
ENVIRONMENT – Standard Model
Temperature: 0 to 54 ºC (32 to 129 ºF)
Exposure: Inadvertent splashing or spray of water on
keypad is acceptable. Not warranted for outdoor use.
(See Weatherized below)
Extreme Weatherized Model (Option WX)
Outside Module – Temperature: -40 to 54 ºC (-40 to 129 ºF)
Exposure: Direct exposure to rain and snow.
Inside Module – Temperature: 0 to 54 ºC (32 to 129 ºF)
Exposure: Drip proof. Inadvertent splashing or spray of
water is acceptable. (Uses ‘AA’ Batteries)
New Weatherized Model (Option W)
Temperature: -20 to 54 ºC (-4 to 129 ºF)
Exposure: Direct exposure to rain and snow.
SS control SyStemS
om500 KeyPad aUdIt-traIl locKS & SPecIFIcatIonS
OM500 KEYPAD AUDIT-TRAIL LOCKS
3
ProXImIty card reader locKS
PROXIMITY CARD READER LOCKS
The Stanley OMNILOCK PDV (Proximity Dual
Validation) card reader locks allow access control
for up to 2000 individual users per door. Users
may gain access by 4-10 digit keypad code only,
by HID proximity card or keyfob only or, for areas
requiring higher levels of access control, users
may be required to present a proximity card or enter a code followed by a 3 to 6 digit PIN. Of course, some
end users may prefer to use HID proximity
credentials, and these locks are ordered,
accordingly, with NO KEYPAD (Option PH).
The powerful electronics module records the
date, time and identity of the last 50,000
events. Audited events include any entries,
entry attempts, tampers, time-scheduled
access level changes; and key-bypass
detection is also an option. What truly
sets these products apart from is that
they program faster than many standalone systems. In addition, the
cylindrical OP2000 locks install in a
standard ANSI 156.2 (formerly 161)
door prep and require NO extra holes to be drilled in the door.
These locks program at the door using any one of the approved
Windows CE Devices with infrared (IR) technology.
Stanley offers the proximity readers in Quick-Adapter
configuration for easy retrofit to many existing locks.
The proximity system is available in a cylindrical,
mortise, mortise with-deadbolt, quick adapter, wall
mount system, and exit device trim configurations.
The powerful electronics module (EM) will retrofit to
existing OM50, OM100,OM300, OM500, or to the
Magnetic-card reader OM2000 systems.
SYSTEM REQUIREMENTS
The Stanley OMNILOCK Proximity Card Cylindrical, Mortise, Quick Adapter, or Wall Mount
System locks are programmable at the door by using any approved Windows PDA. The
OMNILOCK Facility Manager (OFM) software runs on any MS Windows-compatible laptop or PC and can manage over 65,000 users in its powerful database. If users want to
enroll their proximity cards, then they must have a Proximity Card Enrollment Reader (not
needed for Keypad-code-only operation).
1) OP2000 Administrator’s Package p/n OMS-11628 (Includes software, manual, Quick
user reference cards, and default programming proximity cards)
2) Proximity Card Enrollment Reader p/n OMD-11507-002
3) HID Proximity Cards and/or Keyfobs (see Price List)
4) Windows  PocketPC with infrared (IR) technology (available from Stanley or offthe-shelf at office supply stores-contact Customer Service for compatible modelsSee image below)
5) Card Reader Locks (Contact Factory for the ordering sequence)
The flat plate p/n OMD12061 (left) is very useful for customers as
they replace their
AlarmLocks or Simplex
L1000 systems.
Above is an ASUS A626
MyPal PocketPC w
 ith
Intel PXA-250 processor.
The stainless weatherized shroud (right) p/n
OMD-12911 is often
used to prevent desert
sand or freezing rain
from accumulating on
the keypads.
4
HID Keyfob
Exit device trims are available for
Stanley Precision, Corbin-Russwin,
Yale, Arrow, Sargent, and Von
Duprin exit devices. These exit
trims are available for standard or
Interchangeable core cylinders and
install quickly into the existing
mechanical trim door preparation
with NO Extra Hole Drilling (Stanley
Precision APEX shown above).
Large spacer 1 3/8"
(part number 1676349)
S ta n d - a l o n e a c c e S
SPECIFICATIONS
The Stanley OMNILOCK PDV Proximity Card Reader
systems offer the combination of the industry’s most
widely-accepted HID proximity technology and the proven
electronic superiority of Stanley OMNILOCK. The PDV
Systems provide all of the superior features and quality that
you have come to expect from Stanley OMNILOCK.
• Capacity of 2000 individual users per door
• Audit trail up to 50,000 events (optional key-by-pass
detection)
•The OMNILOCK Facility Manager, a Microsoft Windows
9X/2000/NT/XP compatible program, runs on a desktop
or laptop computer
•The OMNILOCK Data Link, a Microsoft Windows PDA
compatible program, runs on a handheld PocketPC and
transfers data between the OMNILOCK OFM database
and OP2000 System Lock – NO plug-ins or laptops at
the door!
•The OP2000 System Lock consists of a control module
coupled to a Grade 1 lockset
•Access granted via Proximity card (most bitpatterns
accepted), Keypad Code, or Card or Code plus PIN
•Flash ROM facilitates lock software upgrades via
infrared communication– NO PCBs need to be
changed when software is upgraded!
•Password protected network-compatible software
•‘AA’ Battery-powered (100,000 operations)
•Audit records user identity, date and time
•Time schedule controls access for 8 user groups
•Full electronic and electro-mechanical diagnostics may
be run without removing lock from the door
•Cylindrical locks install in a standard ANSI 156.2
(formerly 161) door preparation
•Electronics easily retrofit to existing OM100, OM300,
OM500, or OM2000 OMNILOCK systems!
ID TYPES
Proximity Card 26-bit, 32-bit, 33-bit, 35-bit Corporate 1000, or
37-bit formats, Keypad ID 4 to 10 digits in length, and/or PIN
lengths of 3 to 6 digits long.
PROGRAMMER ID
Uploads and downloads all programming data, Changes
Access Levels, Enables User Groups, and may run
Diagnostics. Privileges are assignable. Quantity as required.
MANAGER ID
Enables or disables User Groups or sets Access Levels at
doors, privileges are assignable.
GENERAL USER ID
Allows access when access level is at ID Required and user
group is enabled. Quantity 2000 users less masters and
managers.
SERVICE ID
Allows limited use to service personnel-PIN required at all
times. Quantity as required.
ACCESS LEVELS
Level 2: Free passage – unlocked.
Level 3: Remains unlocked after first valid ID
Level 4: Remains unlocked after first valid ID and PIN
Level 5: Enrolled ID required (ID code or prox card)
Level 6: Enrolled ID and PIN required
Level 7: Facility ID card required
Level 8: Lockout (Manager or Programmer ID allowed only
if privileges have been assigned)
ProXImIty card reader locKS
PROXIMITY CARD READER LOCKS
AUDIT LOG
Transactions: Retains last 50,000 events, whether keypad
code, prox card or fob, key bypass detection, antitamper,
attempt by unauthorized user, remote switch operation, or
time scheduled event.
Events Audited: Ten separate events are recorded
Record Format: Date, Time, Identity, Event
TIME SCHEDULE
Sets Access Level and controls access by user
groups automatically at selected preprogrammed
times. May be preprogrammed for holiday scheduling.
Capacity: 144 scheduled events per day, 32 holiday
periods
User Groups: 8
INTERNAL CLOCK
Resolution: 1 minute with leap
year correction
Daylight Savings:
Automatic or manual
corrections
SS control SyStemS
5
maGnetIc card reader locKS
MAGNETIC CARD READER LOCKS
The Magnetic Card Reader locking system will allow access control for up to 2000
individual users per door. Users may gain access by 4-10 digit keypad code only, by
magnetic striped card only, or, in areas requiring higher levels of access control,
users may be required to enter a card or code followed by a 3-6 digit PIN. The powerful electronics module records the date, time and identity of the last 50,000 events.
Audited events include entries, attempts, tampers, time-scheduled access level
changes; and key bypass detection is also an option. What truly sets these products
apart from the other products is that they not only program faster than many standalone access System; but they also install more easily than other systems (every
Cylindrical MDV system installs in a standard ANSI 156.2 (formerly 161) door prep
and requires NO Extra holes to be drilled in the door). These locks program at the
door by using any approved Windows PDA. Stanley offers the MDV System in a
Quick Adapter configuration for easy retrofit to many pre-2004 lever locks. The MDV
systems are available in Cylindrical, Mortise, Mortise-with-deadbolt, Wall Mount, and
Exit Device Trim configurations. Additionally, the powerful OMEM-MDV electronics
module retrofits to existing OM100s, OM300s, and OM500s. Key Bypass Detection
is available on certain MDV locks.
Grade-1 BEST mortise locksets. Standard
or IC core cylinders available, accepts 1 3/8"
to 1 3/4" mortise cylinder. The mortise collar
p/n OMD-11445-001 is required for 1 3/8"
cylinders.
SYSTEM REQUIREMENTS
The Stanley Cylindrical, Mortise, Quick Adapter, or Wall Mount System
Magnetic Card Reader locks are programmable at the door by using any
approved Windows PDA. The database manager software runs on any
MS Windows-compatible laptop or PC and can manage over 65,000 users
in its powerful database. If users want to enroll OMNILOCK’s magnetic cards
or their own Student IDs, Driver’s Licenses, or ATMs, then they must have
a Track-2 Card Reader. (not necessary for Keypad code-only operation).
1) OM2000 Administrator’s Package p/n OMS-11278 (Includes software,
manual, Quick user reference cards, card reader cleaners)
2) Track-2 Card Reader p/n OMD-11274
3) Track-2 Cards p/n OMD-10983-002
4) Windows  CE Device with infrared
technology (available from Stanley or
off the shelf at office supply stores)
5) OM2000 Locks (see examples on
following pages for ordering sequences)
Installs Easier– Std. ANSI 156.2 prep
Programs Faster– 2000 users in <10
seconds Largest Audit Trail– 50,000
events Accepts existing ID Cards
On-the-door diagnostics
6
The versatile Wall Mount System (above) may be
used to control electric strikes, magnetic locks,
electrified exit devices, elevator control boxes or
any electric circuit of 12-24 VDC/RMS voltage, 5
amperes. The Wall Mount above is used to control an electrified Exit Device. The image below
shows a BEST 45H
Mortise lock chassis
interfacing with an
OMEM-M electronics
module during benchtest just prior to
installation.
S ta n d - a l o n e a c c e S
SPECIFICATIONS
The Stanley OMNILOCK MDV Magnetic Card Reader
systems combine the sophistication of an electronic access
control system with the reliability of a commercial Grade-1
lockset. This series of locks provides the superior features
and quality that you have come to expect from Stanley
OMNILOCK.
• Capacity of 2000 individual users
• Audit trail of 25,000 to 50,000 events (optional key
bypass detection)
• The OMNILOCK Facility Manager, a Microsoft®
Windows® 9X/2000/NT/XP compatible program, runs
on a desktop or laptop computer
• The OMNILOCK Data Link, a Windows® PDA
compatible program, runs on a handheld PocketPC and
transfers data between the OMNILOCK OFM database
and the OM2000 System Lock- No plug-ins or laptops
at the door!
• The OM2000 System Lock consists of a control module
coupled to a Grade 1 lockset
• Access granted via Magnetic stripe card (Track 2 or
Track 3), keypad code, or card or code plus PIN
• Flash ROM facilitates lock software upgrades via
infrared communication– NO PCB change-outs!
• Password protected network-compatible software
• Battery powered (5 years / 120,000 operations)
• Audit records user identity, date and time
• Time schedule controls access for 8 user groups
• Full electronic and electro-mechanical diagnostics may
be run without removing lock from the door
• Cylindrical locks install in a standard ANSI 156.2
(formerly 161) door preparation
• Electronics easily retrofit to existing OM100, OM300, or
OM500 OMNILOCK systems!
• Rugged steel-zinc construction
FUNCTIONAL SPECIFICATIONS
ID TYPES
Card ID length variable to 19 digits, Keypad ID 4 to 10 digits
in length, and PIN lengths 3 to 6 digits long.
PROGRAMMER ID
Upload/download programming data, Change Access
Levels, Group Enabling, and run Diagnostics. Privileges are
assignable. Quantity as required.
MANAGER ID
Enables or disables User Groups, sets Access Levels at
doors, privileges are assignable.
GENERAL USER ID
Allows access when access level is at ID Required and user
group is enabled. Quantity 2000 users less masters and
managers.
SERVICE ID
Allows limited use to service personnel-PIN required at all
times. Quantity as required.
maGnetIc card reader locKS
MAGNETIC CARD READER LOCKS
ACCESS LEVELS
Level 2: Free passage - unlocked.
Level 3: Remains unlocked after first valid ID
Level 4: Remains unlocked after first valid ID and PIN
Level 5: Enrolled ID required (ID code or prox card)
Level 6: Enrolled ID and PIN required
Level 7: Facility ID card required
Level 8: Lockout (Manager or Programmer ID allowed only
if privileges have been assigned)
AUDIT LOG
Transactions: Retains last 50,000 events, whether keypad
code, prox card or fob, key bypass detection, antitamper,
attempt by unauthorized user, remote switch operation, or
time scheduled event.
Events Audited: Ten separate events are recorded
Record Format: Date, Time, Identity, Event
TIME SCHEDULE
Sets Access Level and controls access by user groups
automatically at selected preprogrammed times. May be
preprogrammed for holiday scheduling.
Capacity: 144 scheduled events per day, 32 holiday periods
User Groups: 8
INTERNAL CLOCK
Resolution: 1 minute with leap year correction
Daylight Savings: Automatic or manual corrections
SS control SyStemS
7
HardWare SPecIFIcatIonS
HARDWARE SPECIFICATIONS (Mortise)
Lock Body: Heavy duty, Grade-1 BEST 45H (Standard) or Schlage L-9070 or L-9453 series Mortise locks,
Material:
Latch:
Cold rolled steel and zinc dichromate finish for oxidation resistance. Levers conform to BHMA standard of
175 foot-pounds of torque without shearing.
2 ¾" backset standard, brass with ¾" throw.
Latch Face: Brass, bronze or stainless steel face plates. 1 ¼" x 8"
Strike Plate: ASA, 1 ¼" x 4 7/8" with 1-1/4" lip to center dimension; ANSI Standard 115.1
Handing:
Field reversible; Specify Handing on orders
Door Thickness: 1 ¾" to 2" standard (special order for up to 6-inch door thickness available)
Deadbolt:
1" throw (optional). Also available with Mortise Deadbolt Lockout Privacy Function (MDL)
Key Cylinder: Solid brass 6-pin 1 3/8" or 1 3/4" length mortise cylinder (furnished with Dummy Cylinder)
I/C Cylinder:For use with 6 or 7-pin interchangeable cores (I/C core not included)
Finishes:
605-US3 (Polished Brass), 606-US4 (Satin Brass), 612-US10 (Satin Bronze), 613-US10B (Oil Rubbed
Bronze), 625-US26 (Polished Chrome), 626-US26D (Satin Chrome) Standard. No split finishes.
Function:
Lever retracts latch bolt from either side unless the outside (cylinder side) is locked. Unlocked from outside
with valid ID code, with valid card, with ID or card plus PIN, or by key. Inside trim is always free passage. For
standard deadbolt option, lever also retracts deadbolt from either side. The MDL option allows privacy
lockout function if deadbolt is thrown (key override)
Installation: Standard ANSI door preparation for mortise lockset with 2 ¾" backset and a door jamb not greater than
¾". Two 5/16" anti-rotation holes are required. Weatherized (Option WX) models require an additional ¾"
diameter through-door bore, yet Weatherized (Option W) do not.
MORTISE LOCKSET CERTIFICATION
All locks conform to ANSI Standard 156.13, Series 1000, Grade 1 requirements. Levers comply with “Americans With
Disabilities Act of 1992”. Lockset listed to UL standards for safety and fire (90 minutes) by Underwriters Laboratories Inc.
PocketPC infrared programming of a Stanley
OMNILOCK Magnetic Card Reader Cylindrical
lock (shown above).
8
S ta n d - a l o n e a c c e S
Lock Body: Heavy duty Grade-1 BEST 93K series (Standard) or Schlage ND-80 series, critical latch and chassis
components are brass or corrosion-treated steel. 2 ¼" diameter to fit 2 ⅛" hole in door (conforms to ANSI A1152.2).
Material: Cold rolled steel and zinc dichromate finish for oxidation resistance with precision cast steel retractor. Lock
levers surpass BHMA standards of 450 inch-pounds of torque. 4 ¾" Backsets available. 2 ⅛" diameter bore is required.
Latch: 2 ¾" backset standard, brass with 9/16" throw. Housing is steel-zinc dichromate finish for oxidation resistance.
1" diameter bore is required.
Latch Face: Brass, bronze or stainless steel face plates. 2 ¼" x 1 ⅛" .
Strike Plate: Square corner, 1 ⅛" x 2 ¾" T strike with 1 ¼" lip-to-center dimension; ANSI Standard 115.3
Handing: Field reversible; Shipped right-handed
Lever handles: High quality zinc alloy. Trim components are brass or bronze. Body is approximately 1 ⅝" in diameter;
Handle is approximately 4 ¾" long (from center-line of chassis). #14 and #15 levers conform to California Administrative
Code Title 19 and Title 24. All three styles of levers conform to the Illinois Accessibility Standard.
Door Thickness: Available for 1 ¾" to 2 ¼" doors. Door thickness must be specified.
HARDWARE SPECIFICATIONS
HARDWARE SPECIFICATIONS (Cylindrical)
Key Cylinder: Solid brass 6 pin cylinder with two brass keys. Keyed 5 pin with Arrow ‘CS’ keyway on Arrow locks or
Schlage ‘C’ keyway with Schlage locks.
I/C Core: For use with 6 or 7 pin small or large format I/C cores (I/C cores not included)..
Finishes: 605-US3 (Polished Brass), 606-US4 (Satin Brass), 612-US10 (Satin Bronze), 613-US10B (Oil Rubbed Bronze),
625-US26 (Polished Chrome), 626-US26D (Satin Chrome) Standard. No split finishes.
Trim: Through-bolted with independent springs for each lever.
Function: Lever retracts latch bolt from either side unless the outside (cylinder side) is electrically locked. Unlocked from
the outside with valid ID code, with valid card (OM2000 only), with ID or card plus PIN (OM2000 only), or by key. Inside
always free passage.
Installation: Standard ANSI 156.2 (formerly 161) door preparation for cylindrical lockset with 2 ¾" backset and door stop
not greater than ¾". Two anti-rotation holes required. Weatherized models require an additional ¾" diameter throughdoor hole.
CYLINDRICAL LOCKSET CERTIFICATION
Locksets conform to the ANSI Standard 156.2, Series 4000, Grade 1 requirements.
Conforms to Federal Specs. FFH-106C, Type 161. Lever handles comply with “The
Americans With Disabilities Act of 1992”. Lockset listed to UL standards for safety
and fire (90 minutes) by Underwriters Laboratories.
The OMNILOCK Cylindrical
locks install without drilling
any holes and install in the
Standard ANSI door prep with
NO Drilling!!!
SS CONTROL SYSTEMS
9
HoW to order
HOW TO ORDER:
500-Series 45HOM Keypad-Only Mortise Locks
Ordering Example:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Select Series (45HOM)
Select Cylinder core housing (0 non-IC, 7 SFIC no core)
Select Function code (DV non-deadbolt, TV with deadbolt)
Select Lever style (3, 14, 15, 16)
Select Trim style (OM500 500-user keypad-only electronics)
Select Rose style (H)
Select Housing finish {B (black), G (grey), C (chrome)}
Select Lock trim finish (612, 613, 626, 690)
Select Door hand (RH, RHRB, LH or LHRB)
Select Options (Thick Door- specify Door Thickness i.e. 2”),
W (weatherized –20º to +54ºC), WX, TAC (Tactile lever handle)}
45HOM
45HOM-7
45HOM-7-DV
45HOM-7-DV-15
45HOM-7-DV-15-OM500
45HOM-7-DV-15-OM500-H
45HOM-7-DV-15-OM500-H-C
45HOM-7-DV-15-OM500-H-C-626
45HOM-7-DV-15-OM500-H-C-626-RH
45HOM-7-DV-15-OM500-H-C-626-RH-W
NOTE: The above example is for an OMNILOCK Mortise, 7-pin Small Format IC Cylinder, Non-Deadbolt, 15-Style Lever
Trim, OM500 keypad lock, Chrome Electronic Housing, 626 Finish, Right-handed, Weatherized.
HOW TO ORDER:
500-Series 93K Keypad-Only Cylindrical Locks
Ordering Example:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Select Series (93KOM)
93KOM
Select Cylinder housing (0- Non-IC, 7– Best IC no core)
93KOM-0
Select Function code (DV- with key)
93KOM-0-DV
Select Lever style (14 curved, 15 contour angle, 16 flat)
93KOM-0-DV-15
Select Trim style (OM500)
93KOM-0-DV-15-OM500
Select Housing finish {B (black), G (grey), C (chrome)}
93KOM-0-DV-15-OM500-B
Select Strike package (STK- Standard, S3- ANSI)
93KOM-0-DV-15-OM500-B-S3
Select Lever finish (612, 613, 626. 690, Satin)
93KOM-0-DV-15-OM500-B-S3-626
Select Options (TAC-Tactile lever, SCH– Schlage non-IC,
93KOM-0-DV-15-OM500-B-S3-626-SAR
COR- Corbin-Russwin, MED- Non-IC Medeco, SAR- Non-IC Sargent, YAL- Non-IC Yale, SCHRC- Schlage removeable
core, (Thick Door (specify Door Thickness), W (weatherized –20º to +54ºC with battery packs),
WX- Extreme Weatherized with ‘AA’ Batteries on Inside of Door, ¾" – ¾ inch throw)
NOTE: The above example is for an OMNILOCK Cylindrical, Non-IC Cylinder Prep, 15-Style Lever Trim, OM500 keypad lock,
Black Electronic Housing, S3 ANSI Strike, 626 Finish, Sargent 10-line Cylinder Prep (the SAR prep will also accommodate
the Medeco non-IC Core when matched with the correct tailpiece throw member kit)
HOW TO ORDER:
500-Series 93K Keypad-Quick Adapters for Exit Devices
Ordering Example:
1.
2.
3.
4.
5.
6.
7.
Select Series (QAXOM)
QAXOM
Select Cylinder housing (0- Non-IC, 7– Best IC no core)
QAXOM-7
Select Lever style (14 curved, 15 contour angle, 16 flat)
QAXOM-7-14
Select Trim style (OM500)
QAXOM-7-14-OM500
Select Housing finish {B (black), G (grey), C (chrome)}
QAXOM-7-14-OM500-B
Select Lever finish (612, 613, 626, 690)
QAXOM-7-14-OM500-B-613
Select Adapter plate (CY1– Corbin-Russwin/Yale,
QAXOM-7-14-OM500-B-613-PH2
PH2– Precision, SA7, 8, 9– Sargent Series, VD8– Von Duprin 98/99 EO, VD9– Von Duprin 98/99F)
8. Select Door Hand (RHRB, LHRB)
QAXOM-7-14-OM500-B-613-PH2-LHRB
9. Select Options {SCH– Schlage non-IC, (Thick Door (specify
QAXOM-7-14-OM500-B-613-PH2-LHRB-W
Door Thickness), W (weatherized –20º to +54ºC)}
NOTE: The above example is for an OMNILOCK Exit Trim, 7-pin Small Format IC Cylinder, 14-Style Lever Trim, OM500
keypad lock, Black Electronic Housing, 613 Finish, Precision APEX, Left-handed, Weatherized.
10
S ta n d - a l o n e a c c e S
500-Series 45HOM Keypad-Only Wall Mount Systems
1.
2.
3.
4.
5.
Select Series (OMWMS)
Select Cylinder core housing (BE- Best 5E Utility Cylinder)
Select Trim style (OM500 500-user keypad-only electronics)
Select Housing finish {B (black), G (grey), C (chrome)}
Select Options W (weatherized battery packs –20º to +54ºC);
WX (Extreme Weatherized with ‘AA’ Batteries inside of door)
OMWMS
OMWMS-BE
OMWMS-BE-OM500
OMWMS-BE-OM500-B
OMWMS-BE-OM500-B-WX
NOTE: The above example is for an OMNILOCK Wall Mount System, Best 5E Utility Cylinder, OM500 keypad lock, Black
Electronic Housing, Extreme Weatherized.
HOW TO ORDER:
HoW to order
HOW TO ORDER:
Ordering Example:
500-Series Electronic Locks
Ordering Example:
1.
2.
3.
4.
5.
Select Series (OMEM)
Select Lockset type (C- Cylindrical; M- Mortise)
Select Trim style (MDV, PDV, OM500)
Select Housing finish {G (Grey), B (Black), C (Chrome)}
Select Options (W (weatherized –20º to +54ºC)
OMEM
OMEM-C
OMEM-C-OM500
OMEM-C-OM500-C
OMEM-C-OM500-C-W
NOTE: The above example is for an OMNILOCK Electronic Module, Cylindrical Lock Type, OM500 Keypad-Only Trim Style,
Chrome Electronic Housing, and Weatherized Environmental configuration.
HOW TO ORDER:
500-Series Quick Adapters for pre-2004 non-BEST Locks
Ordering Example:
1.
2.
3.
4.
Select Series (QASOM)
Select Trim style (MDV, PDV, OM500)
Select Housing finish {B (black), G (grey), C (chrome)}
Select Options W (weatherized –20º to +54ºC)
QASOM
QASOM-OM500
QASOM-OM500-C
QASOM-OM500-C-W
NOTE: The above example is for a Stanley OMNILOCK Quick Adapter for Schlage D-Series or AL-Series, OM500 KeypadOnly Trim Style, Chrome Electronic Housing, Weatherized configuration.
The Stanley OMNILOCK Wall Mount System is an extremely versatile device
that can control virtually ANY electrified hardware or electronic/electrical
circuit. An integrated Form-C relay features two separate sets of contacts
(one normally-open and one normally-closed) that can be individually or
simultaneously used to control the AC or DC voltage of 12-24 Volts to an
electric strike, magnetic lock, electrified lockset, electric gate, or even an
elevator call-switch. Shown in image at left is Wall Mount System p/n
OMWMS-BE-OM500-B-WX that is being used to control a low-power door
operator.
(Note the auxiliary override key switch on the side of the stanchion).
SS control SyStemS
11
HoW to order
HOW TO ORDER:
45HOM Mortise Card Reader Locks
Ordering Example:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Select Series (45HOM)
45HOM
Select Cylinder core housing (0 non-IC, 7 SFIC no core)
45HOM-7
Select Function code (DV non-deadbolt, TV with deadbolt)
45HOM-7-DV
Select Lever style (3, 14, 15, 16)
45HOM-7-DV-15
Select Trim style (MDV, PDV, PH, MS, K)
45HOM-7-DV-15-MDV
Select Rose style (H)
45HOM-7-DV-15-MDV-H
Select Housing finish {B (black), G (grey), C (chrome)}
45HOM-7-DV-15-MDV-H-C
Select Lock trim finish (612, 613, 626, 690)
45HOM-7-DV-15-MDV-H-C-626
Select Door hand (RH, RHRB, LH or LHRB)
45HOM-7-DV-15-MDV-H-C-626-RH
Select Options (Thick Door- specify Door Thickness i.e. 2”),
45HOM-7-DV-15-MDV-H-C-626-RH-W
W (weatherized –20 to +54C), KOS- key bypass detection option, TAC- Tactile Lever Handle)
NOTE: The above example is for an OMNILOCK Mortise, 7-pin Small Format IC Cylinder, Non-Deadbolt, 15-Style Lever
Trim, Magnetic Card-plus-Keypad Dual Validation Trim Style, Chrome Electronic Housing, 626 Finish, Right-handed,
Weatherized.
HOW TO ORDER:
9KOM Cylindrical Card Reader Locks
Ordering Example:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Select Series (93KOM)
93KOM
Select Cylinder housing (0-Non-IC, 7–Best IC no core)
93KOM-0
Select Function code (DV- with key)
93KOM-0-DV
Select Lever style (14 curved, 15 contour angle, 16 flat)
93KOM-0-DV-15
Select Trim style (MDV, PDV, PH, MS, K)
93KOM-0-DV-15-PDV
Select Housing finish {B (black), G (grey), C (chrome)}
93KOM-0-DV-15-PDV-B
Select Strike package (STK- Standard, S3- ANSI)
93KOM-0-DV-15-PDV-B-S3
Select Lever finish (612, 613, 626)
93KOM-0-DV-15-PDV-B-S3-626
Select Options (TAC-Tactile lever, SCH– Schlage non-IC,
93KOM-0-DV-15-PDV-B-S3-626-SAR
COR- Corbin-Russwin, MED- Non-IC Medeco, SAR- Non-IC Sargent, YAL- Non-IC Yale, SCHRC Schlage removeable
core, (Thick Door (specify Door Thickness), W (weatherized –20 to +54C with battery packs), WX- Extreme Weatherized
with ‘AA’ Batteries on Inside of Door)
NOTE: The above example is for an OMNILOCK Cylindrical, Non-IC Cylinder Prep, 15-Style Lever Trim, Proximity-withKeypad lock, Black Electronic Housing, S3 ANSI Strike, 626 Finish, Sargent 10-line Cylinder (the SAR prep accommodates
Medeco non-IC Core when matched with correct tailpiece throw member kit.
One of OMNILOCK’s advantages has always
been the fact that all OMNILOCK systems
install with a minimum of door preparation or
damage. The Stanley OMNILOCK exit trims
install without drilling any additional holes.
They install in the Standard door prep for a
mechanical exit device trim with NO Drilling.
12
S ta n d - a l o n e a c c e S
Quick Adapter for Exit Devices
1.
2.
3.
4.
5.
6.
7.
Select Series (QAXOM)
QAXOM
Select Cylinder housing (0- Non-IC, 7– Best IC no core)
QAXOM-7
Select Lever style (14 curved, 15 contour angle)
QAXOM-7-14
Select Trim style (OM500)
QAXOM-7-14-OM500
Select Housing finish {B (black), G (grey), C (chrome)}
QAXOM-7-14-OM500-B
Select Lever finish (612, 613, 626)
QAXOM-7-14-OM500-B-613
Select Adapter plate (CY1– Corbin-Russwin/Yale,
QAXOM-7-14-OM500-B-613-PH2
PH2– Precision, SA7, 8, 9– Sargent Series, VD8– Von Duprin 98/99 EO, VD9– Von Duprin 98/99F)
8. Select Door hand (RHRB, LHRB) QAXOM-7-14-OM500-B-613-PH2-LHRB
9. Select Options {SCH– Schlage non-IC, (Thick Door (specify QAXOM-7-14-OM500-B-613-PH2-LHRB-W Door
Thickness), W (weatherized –20º to +54ºC)}
HoW to order
HOW TO ORDER:
Ordering Example:
NOTE: The above example is for an OMNILOCK Exit Trim, 7-pin Small Format IC Cylinder, 14-Style Lever Trim, OM500
keypad lock, Black Electronic Housing, 613 Finish, for a Precision APEX exit device (not included), Left-handed,
Weatherized.
HOW TO ORDER:
Card Reader Electronic Modules
Ordering Example:
1.
2.
3.
4.
5.
Select Series (OMEM)
Select Lockset type (C- Cylindrical; M- Mortise)
Select Trim style (MDV, PDV, OM500)
Select Housing finish {G (Grey), B (Black), C (Chrome)}
Select Options (W (weatherized –20º to +54ºC)
OMEM
OMEM-M
OMEM-M-PDV
OMEM-M-PDV-B
OMEM-M-PDV-B-W
NOTE: The above example is for an OMNILOCK Electronic Module, Mortise Lock Type, Proximity-with-Keypad Dual
Validation Trim Style, Black Electronic Housing, and Weatherized Environmental configuration. This unit is designed to be
paired with (and is inoperable without) a OMNILOCK motorized lockset.
HOW TO ORDER:
Card Reader Wall Mount Systems
Ordering Example:
1.
2.
3.
4.
5.
Select Series (OMWMS)
Select Cylinder core housing (BE- Best 5E Utility Cylinder)
Select Trim style (MDV- Magnetic Card, PDV- Proximity Card)
Select Housing finish {B (black), G (grey), C (chrome)}
Select Options W (weatherized battery packs –20º to +54ºC);
WX (Extreme Weatherized with ‘AA’ Batteries inside of door)
OMWMS
OMWMS-BE
OMWMS-BE-MDV
OMWMS-BE-MDV-C
OMWMS-BE-MDV-C-WX
NOTE: The above example is for an OMNILOCK Wall Mount System, Best 5E Utility Cylinder, Magnetic Card Dual Validation
lock, Chrome Electronic Housing, WX Extreme Weatherized Configuration.
Card Reader Quick Adapters for Schlage D-Series and ALSeries Cylindrical Locks (D-50, 53, 70, 73, 80, 82 and AL-Series Locks
HOW TO ORDER:
Ordering Example:
1.
2.
3.
4.
Select Series (QASOM)
Select Trim style (MDV, PDV, OM500)
Select Housing finish {B (black), G (grey), C (chrome)}
Select Options W (weatherized –20º to +54ºC),
IC- for IC Schlage locks, STD- for Standard Core Schlage locks
QASOM
QASOM-MDV
QASOM-MDV-C
QASOM-MDV-C-W
NOTE: The above example is for a Stanley OMNILOCK Quick Adapter for Schlage D-Series or AL-Series, Magnetic Cardplus-Keypad Dual Validation Trim Style, Chrome Electronic Housing, Weatherized configuration.
SS control SyStemS
13
FINISHES
MISCELLANEOUS – FINISHES
LEVER STYLES
612-satin bronze,
clear coated
613-oxidized satin
bronze, oil rubbed
LEVER STYLES
STRIKES
MORTISE FUNCTIONS
Cylindrical #16
Cylindrical #15
Cylindrical #14
Mortise #3
14
690-dark bronze,
powder coated
626-satin
chromium plated
Mortise #14
Mortise #15
Mortise #16
STRIKES
8KS2 Strike (Standard)
Dimension: Conforms to ANSI A115.2 for 1 3/8"
8KS3 Strike
Dimension: Conforms to ANSI A115.2 for
doors (2 3/4" x 1 1/8" with curved lip and box).
To order: (with unit) designate “STK”.
To order: (without unit) designate 8KS2 + finish.
1 3/4" doors (4 7/8" x 1 1/8" with curved lip).
To order: (with unit) designate “S3”.
To order: (without unit) designate 8KS3 + finish.
MORTISE F U N C T I O N S
TV
Deadbolt with
key override
Latchbolt operated by:
• Outside key
• Outside lever - unless locked by
internal motor drive mechanism
• Inside lever
Latchbolt deadlocked by:
• Auxiliary latch
Deadbolt operated by:
• Outside key
• Inside turn knob
• Outside lever when lever is
unlocked by internal motor drive
mechanism (retracts only)
• Inside lever (retracts only)
Outside lever locked and unlocked by:
• Internal motor drive mechanism
operated by time-activated electronic signal or by valid card/PIN
DV
Latchbolt with
key override
Latchbolt operated by:
• Outside key
• Outside lever - unless locked by
internal motor drive mechanism
• Inside lever
Latchbolt deadlocked by:
• Auxiliary latch
Outside lever locked by:
• Internal motor drive mechanism
operated by time-activated electronic
signal or by valid card/PIN
Outside lever unlocked by:
• Internal motor drive mechanism
operated by time-activated electronic signal or by valid card/PIN
Inside lever is always unlocked
Inside lever is always unlocked
S TA N D - A L O N E A C C E S
SS control SyStemS
noteS
NOTES
15
STAND-ALONE ACCESS CONTROL SYSTEMS
Stanley Security Solutions, Inc.
6161 E. 75th Street Indianapolis, Indiana 46250
© 2010 Stanley Security Solutions, Inc. • www.stanleysecuritysolutions.com
10M 210
BAS039
Product information contained in this catalog has been compiled and presented with as much care and completeness as is reasonably possible. However, errors
or mistakes may be present. Therefore, no guarantee can be made or should be assumed or implied with regards to product information contained in this catalog.
Download PDF