Safety Bus System
AS-Interface Safety at Work
S
R
O R
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
®
AS-Interface Safety at Work
(SaW) is the first safety bus system based upon the open standard of AS-International.
Safety components such as
Emergency Stop command devices, safety switches, solenoid interlocks or safety light barriers are simply connected to the yellow AS-Interface cable. For the evaluation of the safety signals a “Safety Monitor” is merely added to the AS-
Interface system.
AS-Interface Standard in accordance with EN 50295
With the integration of AS-Interface SaW the AS-Interface network will continue to operate unchanged. The well known components, like the standard
AS-Interface master, the standard power supply as well as the
AS-Interface yellow cable will still form the basis of all AS-
Interface installations. Therefore safety functions can be easily added to an exiting machine equipped with AS-Interface SaW.
The heart of safety
The safety monitor analyses all transmitted information from each safety device on the AS-
Interface network and, in case of a safety device being activated or in case of a fault in one of the safety devices, the safety monitor immediately shuts down to create a safe condition. The safety monitor is equipped with one or two redundant pairs of enabling paths for applications up to Control Category 4 according to EN 954-1.
Each safety function of the monitor can be set with simple drag & drop software. Afterwards the parameters are downloaded into the safety monitor and protected with a password.
Easy and safe
Safe transmission mechanism
The communication protocol for safety relevant applications is based on the unchanged AS-
Interface Standard transmission.
With each AS-Interface master call each safety device answers in return with a preset data telegram. This information is analysed and in case of a deviation from the pre-set values the enabling fields are opened. The maximum response time for a safe shutdown is 40 ms.
Cost reduction with
AS-Interface Safety at Work
Reduce cost and installation time – A never ending story.
During installation and machine commissioning as well as during maintenance, AS-Interface SaW supports the user with integrated system diagnosis. It provides detailed information about the cause and place of the failure, and enables the user to quickly find and analyse a malfunction and therefore minimise machine downtime. With AS-
Interface Safety at Work you can directly reduce your cost.
More flexibility with
AS-Interface Safety at Work
For the realisation of individual safety solutions, SCHMERSAL offers the maximum amount of flexibility with its diverse range of safety devices. Depending on the application the user can choose the optimal solution out of an extensive product basket.
As AS-Interface SaW is an open system, the user has also the possibility to include additional
Safety components from other suppliers. AS-Interface Safety at Work fulfils the safety requirements to the highest standards.
2
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
S
R
O R
Less installation time with
AS-Interface Safety at Work
Easier and quicker with AS-
Interface SaW: Choose a Safety device – Connect it to the yellow
AS-Interface cable – Set the safety function in the safety monitor. – That’s it.
No further settings are required at each of the safety devices, the bulky parallel wire cables between the safety devices in the field and the switching cabinet are reduced and wiring time is decreased. The power supply for all safety sensors is supplied over the single yellow AS-Interface cable.
AS-Interface Safety at Work overview
Controller
AS-Interface
Power Master
Safety guard monitoring
E-Stop Command
Safety monitor
Two-Hand Control
AS-Interface SaW
System Features
• Up to 31 standard and safety slaves on the
AS-Interface system
• No Safety PLC necessary
• Safety-relevant signals can be allocated into groups and multiple
Safety monitors may be connected
• Response time is max. 40 ms
• Safety-relevant signals can be integrated into plant diagnostics
• Certified up to Control
Category 4 in accordance with EN 954-1
• Certified by the TÜV
(German Technical
Inspectorate)
Foot switch
Standard AS-Interface Module
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
3
AS-Interface Safety at Work
ASM
• Safety monitor
• Control Category 4 to EN 954-1
• Monitor for AS-Interface SaW compatible safety device, i.e. safety switches, solenoid interlocks, Emergency-Stop buttons,
2-Hand control, light grid and light curtains
• AS-Interface connection
• One or two redundant pairs of enabling paths
• Additional outputs (transistor, short-circuit proof)
• Configurable functions: AND logical element, OR logical element,
Start devices, Start-up test
• Edge-sensitive start push button
• Feedback circuit to monitor external contactors
• LEDs to diplay switching conditions
• Operating voltage 24 VDC
S
R
O R
Technical data
Standards:
Control category:
Enclosure:
Mounting:
Screw terminals:
Protection class:
U b
Ib:
:
Residual ripple:
Switch-on peak current:
AS-Interface operating voltage:
AS-Interface operating current:
AS-Interface specification:
Configuration interface:
Inputs:
Input signal:
Outputs:
EN 50295, EN 61496-1 (1997), IEC/EN 60204-1, EN 954-1, IEC 61508
4
Polyamide PA 66, black snaps onto standard DIN rail to EN 50022 max. 2.5 mm
2
(incl. conductor ferrules) terminals IP 20 enclosure IP 20
24 VDC ± 15 %
< 15%
ASM E1-R2: 0,15 A
ASM E2-R2/R2: 0,2 A
600 mA
18.5 ... 31.6 V
< 45 mA
Profile - Monitor 7.F
RS232: 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits
1.Y1,1.Y2
„Y1, Y2“: le < 10 mA at 24 VDC (opto coupler, high-active)
ASM E1-R2: 1.13/14,1.23/24, 1 enabling path (redundant);
ASM E2-R2/R2: 1.13/14,1.23/24, 2.13/14, 2.23/24,
Utilisation category:
I e
/U e
:
Switching voltage:
I the
:
Max. fuse rating:
Additional outputs:
Switch-on time:
Response time:
Indications:
2 enabling paths (redundant)
AC-15, DC-13
3 A / 230 VAC
1 A / 24 VDC max. 230 VAC
3 A per output circuit
4 A (slow blow), external transistor outputs, 200 mA total, short-circuit proof-type, positive-switching
< 10 s
< 40 ms
AS-Interface: voltage LED green, communication LED red;
Enabling paths: LED green, yellow, red
EMC rating:
Overvoltage category:
Resistance to vibration:
Resistance to shock:
Ambient temperature:
Storage and transport temperature:
Weight:
Note: conforming to EMC Directive
III to DIN VDE 0110
5 ... 55 Hz / amplitude 0.35 mm
± 15 % at the regulation point
10 g / 16 ms
– 20 °C … + 60 ºC
– 30 °C … + 70 ºC
ASM E1-R2: approx. 350 g;
ASM E2-R2/R2: approx. 450 g
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Approvals
F C D
C
Ordering details
ASM E
➀
No. Replace Description
➀
1-R2
2-R2/R2
1 enabling field
(redundant)
2 enabling fields
(redundant)
Note
The safety monitors ASM E1-R2 and ASM E2-R2/R2 evaluate all transmitted information from each safety device on the AS-Interface network. For the safe guarding of different applications various AS-Interface Safety at Work compatible safety devices are needed, i.e. safety switches, solenoid interlocks, safety sensors, E-stop buttons as well as safe input modules.
The AS-Interface Safety at Work can be used in applications up to control category 4 according to EN 954-1 with the appropriate safety devices and systems.
4
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
Note
• The installation of different safety areas is possible with numerous safety monitors working alongside each other. The maximum number of safety devices including the safety monitors may not exceed 31 participants.
• The allocation of the safety devices to one or more safety monitors is achieved with the help of the configuration software ”asimon“.
• The wiring diagram shows the safety monitor
ASM E2-R2/R2 with start-pushbuttons and feedback loops.
• No safety devices are displayed, because they are installed in the field i.e. on the safety guards itself. The data connection between the safety monitor and the decentralised safety slaves is established via the AS-
Interface network.
• For the operation of AS-Interface Safety at
Work system, a standard controller, an AS-
Interface Master and AS-Interface power supply, must always be used in the application.
• With the RJ 45 connector the safety monitor is configured and started up.
• Start push button
H
A start push button (NO) can optionally be connected to the ASM. With the guard door(s) closed, the enabling paths are then not closed until the start push button has been operated. If neither start button nor feedback circuit are required, then no connections are required to the terminals
(1Y1/2, 2Y1/2).
Wiring diagram
+ 24 VDC
0 V
AS-i-
AS-i+
+ 24 VDC
0 V
S1
S2
N
M1 M2
AS-i+ AS-i1Y1 1Y2 2Y1 2Y2
1.32
2.32
1.13
1.23
2.13
2.23
AS-
Interface
RS
232
L+
24 V
M FE
K1
K3
K2
K4
1.14
1.24
2.14
2.24
K5
K6
L1
L1 L2 L3
3
M
+ 24 VDC
K5
K6
N
K7
2.14
2.24
K8
• Output expander module
For additional contacts by means of more enabling paths and potential-free indication contacts an output expander module is connected to the safety monitor, i.e. to the internal ASM enabling path. For the control of the additional outputs the ASM feedback loop is utilised.
L1 L2 L3
K7
K8
3
M
S
R
O R
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
5
AS-Interface Safety at Work
asimon
The software asimon is a tool for the configuration and commissioning of the
AS-Interface safety monitors.
The configuration of the safety monitor and its safety devices, i.e. E-Stop buttons, solenoid interlocks, safety switches, 2-Hand controls, light curtains etc. is performed by an easyto-use graphical interface. Thus providing safeguarding of hazardous areas present by power-driven machinery.
The asimon offers the user a library of icons representing different safety devices and other functional devices, i.e. one or two independent enabling paths, automatic or monitored start, stop category 0 or 1 etc. For the implementation of a new safety application the required safety devices are selected from the icon library, parameterised and assigned to the respective enabling path.
Following the successful configuration and download, the safety monitor and the safety devices can be tested and monitored with asimon.
The following functions are available with the asimon software:
• Configuration of different safety devices
• Configuration of start-modules
• Configuration logical combinations
(AND, OR, RS Flip-Flops)
• Configuration of the feedback loops
• Configuration of the operating methods
• Configuration of the system-modules
• Print out of Configuration protocol
Asimon can be used offline as well as online during development and project planning.
The configuration files can be saved and loaded as desired.
The software is compatibable with the
Microsoft® operating system
Windows 95/98/ME/NT/2000/XP.
S
R
O R
System components
• Download cable: Interface cable with two RJ 45 connectors, Length: 0.10 m
Part-number: ASM-DC1
• Configuration cable: Interface cable with one RJ 45 and SUBD 9 connector,
Length: 1.2 m
Part-number: ASM-KC1
Approvals
F
C
Ordering details Note
SET ASM-SWP ASM-startup-package:
ASM-CD
Configuration and diagnostic software package with online documentation on CD-ROM, a configuration- and downloadcable asimon software package:
Configuration and diagnosticsoftware package with online documentation on CD-ROM
Hardware requirements:
• 200 MHz INTEL Pentium® or
AMD® Processor or quicker
• Min. 8 Mbyte free main memory (RAM)
• Min. 8 Mbyte free hard disk memory
• A CD-ROM drive (or 3 1/2 “ disc drive) for the installation
• A mouse
• A free serial interface with
9 SubD-connection
Software requirements:
• Microsoft Windows ® 95/98/ME/NT/2000/XP
Ordering details
Download cable
Configuration cable
ASM-DC1
ASM-KC1
6
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
AZ 16 AS
14
M 12
30
8
9
13
5,5
40
M 12
52
• Safety switch with separate actuator
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector
• Address jack (optional)
• Thermoplastic enclosure
• Coded actuator
• Long life
• Protection class IP 67
S
Technical data
Standards:
Enclosure:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced thermoplastic, self-extinguishing
AS-Interface connection type:
Protection class:
AS-Interface operating voltage: connector M12 x 1
IP 67
26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification:
) 50 mA
Profile S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code2: 0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code transmission
1
2 off on
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
2 off
Parameter bits:
D2/D3 = static code “00”
P0 … P3 not used
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications:
AS-Interface:
Enabling status:
Mechanical life:
EMC rating:
Ambient temperature:
Storage and transport temperature: voltage LED green, communication LED red
LED yellow
> 1 million operations conforming to
EMC Directive
– 25 °C … + 60 ºC
– 25 °C … + 85 ºC
System components
16
ø 5,5 a
ø 5,5
56
40
56
40
27
Straight actuator AZ 15/16-B1 a
27,3
27
Flexible actuator AZ 15/16-B2
ø 5,5
56
40
27,3
27
Flexible actuator AZ 15/16-B6
R
O R
R min. 15
0
R min. 15
0
R min. 4
5
R min. 38
R min. 25
Approvals
F C D
C
Ordering details
AZ 16
➀
-AS
➁➂
No. Replace Description
➀
ST1
ST2
ST3
➁
➂ r r-2254 b
Connector (middle)
Connector (right)
Connector (left)
No latching
Latching 30 N
Latching 5 N
No address jack
Address jack
2
1
Note
4
3
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
Ordering details
Straight actuator
Flexible actuator
Flexible actuator
AZ 15/16-B1
AZ 15/16-B2
AZ 15/16-B6
Further actuators can be found in the chapter
„Safety switches with separate actuator“, see page 1-8.
Actuators must be ordered separately.
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
7
AS-Interface Safety at Work
S
R
O R
AZM 161 AS
6 40 a
5,5 b
M12
130
78
72
56
6
M12
30
• Solenoid interlock
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector
• Magnetic drive through AS-Interface output
• Solenoid power supply via the
AS-Interface network or via an external
24 VDC power supply (p version)
• Address jack (optional)
• Thermoplastic enclosure
• Manual release, emergency exit or emergency release
• High holding force 2000 N
• 30 N latching force (optional)
• Power to unlock / power to lock principle
• Actuating play 5.5 mm in direction of actuation
• Protection class IP 67
Technical data Note
Standards:
Enclosure:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced thermoplastic, self-extinguishing
AS-Interface connection type:
Protection class:
AS-Interface operating voltage: connector M12 x 1
IP 67
26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current: Total:
) 500 mA
AS electronics:
) 50 mA
AS-Interface specification: Profile S-7.B
IO-Code 0x7
ID-Code 0xB
ID-Code2 0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code
1
2 off on transmission
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
A0 Solenoid control
2
Outputs: off
A1 … A3 not used
Parameter bits: P0 Actuator / interlock status
P1 … P3 not used
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications:
AS-Interface:
Enabling status:
Mechanical life:
F max
:
EMC rating: voltage LED green, communication LED red
LED yellow
> 1 million operations
2000 N conforming to EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
The AZM 161 Z version must be selected for applications where safety guard locking is required. The AZM 161 B version has a safetymonitored actuator with supplementary guard locking function.
Depending on the device version, the safety inputs (D0-D3) are connected internally to the solenoid (Z) or actuator contacts (B). The safety monitor (ASM) monitors the coded data transmission.
Output A0 is used to lock or unlock the solenoid of the solenoid interlock. Parameter bit P0 gives the control system feedback about the status of the actuator or solenoid interlock.
Parameter bit:
The status of the actuator or the locking bolt can be monitored by the parameter bit P0 depending on the device:
Device Parameter bit P0
AZM 161 B
AZM 161 B
0
1
AZM 161 Z
AZM 161 Z
0
1 status
Guard locked
Guard unlocked
Guard closed
Guard open
Approvals only without address jack
F C D
C
Ordering details
AZM 161
➀➁
-AS
➂➃➄➅➆
No. Replace Description
➀
➁
➂
➃
➄
B
Z
ST1
ST2 r a b
Actuator monitored
Guard locking monitored
Connector (middle)
Connector (right)
No latching
Latching 30 N
Power to unlock
Power to lock
No address jack
Address jack
1
Note
4
No. Replace Description
➅
➆ p
N
T
Integrated solenoid supply
External solenoid supply
Manual release
Emergency release
Emergency exit
2 3
M12 connector:
1: AS-Interface +
2: Aux – (p)
3: AS-Interface –
4: Aux + (p)
8
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
Contact variants
Integrated power supply
Power to unlock
Guard locking monitored
Contact variants
External power supply
Power to unlock
Guard locking monitored
AS-i
-
+
P0 D0-D3
A0
Actuator monitored
AS-i
-
+
P0 A0 D0-D3
-
+
24 VDC
Actuator monitored
AS-i
-
+
D0-D3 P0
A0
Power to lock
Guard locking monitored
AS-i
-
+
P0 D0-D3
A0
Actuator monitored
AS-i
-
+
D0-D3 P0
A0
AS-i
-
+
D0-D3 A0 P0
-
+
24 VDC
Power to lock
Guard locking monitored
AS-i
-
+
P0 A0 D0-D3
-
+
24 VDC
Actuator monitored
AS-i
-
+
D0-D3 A0 P0
-
+
24 VDC
S
R
O R
Note
Integrated power supply:
The solenoid interlock AZM 161 AS is powered by the AS-Interface. Connection to the AS-
Interface is made via the M12 connector.
The required supply voltage for the solenoid is also supplied by the AS network.
The maximum number of interlocks with integrated power supply and power to lock principle (a) depends solely on the employed
AS-Interface power supply and its electric current output.
To lock or unlock the guard door, the network must supply a maximum current of 0.5 A per solenoid interlock.
External power supply:
The solenoid interlock AZM 161 AS ...p is monitored by the AS-Interface. The locking solenoid is powered by an external power supply. Connection to the AS-Interface and the auxiliary power is made via a single
M12 connector.
The necessary solenoid supply voltage is provided externally (auxiliary power).
Up to 29 solenoid interlocks with an external power supply can be operated on one AS-Interface network depending on the application.
Solenoid control:
An internal output controls the solenoid operation. Depending on the device version, the output bit A0 locks or releases the actuator.
The output bit A0 has the same address as the safety inputs.
Legend
D0 – D3 Coded data for the evaluation
P0
A0 of the safety monitor (4 Bit)
Status signal (1 Bit)
Output for switching the solenoid (1 Bit)
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
9
AS-Interface Safety at Work
ZS 71 AS
40
30
33
M 12
52
18
17,5
24
10
42
M 12
15
• Pull-wire Emergency-Stop switch
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector
• Metal enclosure
• Various spring force variants
(actuating forces)
• Adjustable actuating force
• Wire up to 20 m long
• Reset by push button or key possible
• Protection class IP 65 (with push button and external watertight collar)
Approvals
F C D
C
Ordering details
ZS 71
➀
-AS
➁➂
-
➃
-
➄
/
➅
No. Replace Description
➀
➁
ST1
➂
➃
➄
➅
W
VD
VS
A
G
55 N
200 N
Connector
Without watertight collar
With watertight collar
Without safety function
Push button reset
Key reset
Without position indicator
With position indicator
Without indicator lamp
With indicator lamp
Pre-tensioning force:
For wire length 0 - 5 m
For wire length 5 - 20 m
Technical data
Standards: EN 50295, EN 60947-5-1, EN 954-1
Enclosure: cast aluminium, enamelled
Cover: thermoplastic ultramid
AS-Interface connection type:
Protection class: connector M12 x 1
IP 54
IP 65 for version with push button reset and watertight collar
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
) 50 mA, with indicator lamp
) 130 mA
AS-Interface specification: Profile S-0.B
(with indicator lamp) S-7.B
IO-Code 0x0
Inputs:
Contact Status
1 on
(with indicator lamp) 0x7
ID-Code 0xB
ID-Code2 0xE
D0/D1 = dynamic code transmission
1
2
2
Outputs: off on off
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
A0 Indicator lamp (optional)
A1 … A3 not used
P0 … P3 not used Parameter bits:
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Mechanical life:
Maximum cable length:
Features:
> 1 million operations
20 m wire pull and
EMC rating: breakage detection conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Note
A separate address jack is not available as an option. The addressing must take place via the cable end or the M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
A wide range of accessories is available.
For selection, see page 2-9.
S
R
O R
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
ZS 73 AS
25
M 12
56
28
M 12
70
98
5
170
15
75
• Pull-wire Emergency-Stop switch
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector
• Metal enclosure
• 4 various spring force variants
(actuating forces)
• Adjustable actuating force
• Wire up to 50 m long
• Reset by push button or key possible
• Protection class IP 65 (with push button and external watertight collar)
Approvals
F C D
C
Ordering details
ZS 73
➀
-AS
➁➂
-
➃
/
➄
No. Replace Description
➀
➁
➂
➃
➄
ST1
W
Connector
Without watertight collar
With watertight collar
Without safety function
Push button reset VD
VS
G
Key reset
Without indicator lamp
With indicator lamp
80-100N Pre-tensioning force:
For wire length 0-10 m
120-180N For wire length 10-20 m
195-275N For wire length 20-30 m
295-390N For wire length 30-50 m
Technical data
Standards: EN 50295, EN 60947-5-1, EN 954-1
Enclosure: cast aluminium, enamelled
Cover: thermoplastic ultramid
AS-Interface connection type:
Protection class: connector M12 x 1
IP 54
IP 65 for version with push button reset and watertight collar
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
) 50 mA, with indicator lamp
) 130 mA
AS-Interface specification: Profile S-0.B
(with indicator lamp) S-7.B
IO-Code 0x0
Inputs:
Contact Status
1 on
(with indicator lamp) 0x7
ID-Code 0xB
ID-Code2 0xE
D0/D1 = dynamic code transmission
1
2
2
Outputs: off on off
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
A0 Indicator lamp (optional)
A1 … A3 not used
P0 … P3 not used Parameter bits:
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Mechanical life:
Maximum cable length:
Features:
> 1 million operations
50 m wire pull and
EMC rating: breakage detection conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Note
A separate address jack is not available as an option. The addressing must take place via the cable end or the M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
A wide range of accessories is available.
For selection, see page 2-9.
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
S
R
O R
Phone: 905-738-6688
11
AS-Interface Safety at Work
ZS 75 AS
69
54
23
27
12
33
154
76
71
14
M 12 M 12
70
100
• Pull-wire Emergency-Stop switch
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector
• Metal enclosure
• 4 various spring force variants
(actuating forces)
• Adjustable actuating force
• Wire up to 50 m long
• Reset by push button or key possible
• Protection class IP 65 (with push button and external watertight collar)
Approvals
F C D
C
Ordering details
ZS 75
➀
-AS
➁➂
-
➃
/
➄
No. Replace Description
➀
➁
➂
➃
➄
ST1
W
Connector
Without watertight collar
With watertight collar
Without safety function
Push button reset VD
VS
G
Key reset
Without indicator lamp
With indicator lamp
80-100N Pre-tensioning force:
For wire length 0-10 m
120-180N For wire length 10-20 m
195-275N For wire length 20-30 m
295-390N For wire length 30-50 m
Technical data
Standards: EN 50295, EN 60947-5-1, EN 954-1
Enclosure: cast aluminium, enamelled
Cover: cast aluminium, enamel finish
AS-Interface connection type:
Protection class: connector M12 x 1
IP 54
IP 65 for version with push button reset and watertight collar
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
) 50 mA, with indicator lamp
) 130 mA
AS-Interface specification: Profile S-0.B
(with indicator lamp) S-7.B
IO-Code 0x0
Inputs:
Contact Status
1 on
(with indicator lamp) 0x7
ID-Code 0xB
ID-Code2 0xE
D0/D1 = dynamic code transmission
1
2
2
Outputs: off on off
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
A0 Indicator lamp (optional)
A1 … A3 not used
P0 … P3 not used Parameter bits:
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Mechanical life:
Maximum cable length:
Features:
> 1 million operations
50 m wire pull and
EMC rating: breakage detection conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Note
A separate address jack is not available as an option. The addressing must take place via the cable end or the M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
A wide range of accessories is available.
For selection, see page 2-9.
S
R
O R
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
NAS 311 AS
M 12
85
M 12
97,8
37,8
• E-STOP station
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector
• Pull to reset
• Resistant to chemicals
• Protection class IP 65
Technical data
Standards: EN 50295, EN 60947-5-1, EN 954-1
Enclosure: glass-fibre reinforced polyamide nylon,
Emergency-Stop button: self-extinguishing thermoplastic or aluminium
AS-Interface connection type:
Protection class:
AS-Interface operating voltage: connector M12 x 1
IP 65
26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification:
) 50 mA
Profile S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code2: 0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code transmission
1
2 off on
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
2 off
Parameter bits:
D2/D3 = static code “00”
P0 … P3 not used
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green,
EMC rating: communication LED red
Enabling status: LED yellow conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Approvals
F C D
C
Ordering details
NAS 311
➀
-AS
➁
No. Replace Description
➀
➁
ST1
M
MH
Connector
Thermoplastic enclosure
Metal housing
Metal housing and push button with protection collar
Note
A separate address jack is not available as an option. The addressing must take place via the cable end or the M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
S
R
O R
Phone: 905-738-6688
13
AS-Interface Safety at Work
AST ... AS
• Input module
• 2 safe inputs for mechanical contacts
• Cross-wire monitoring
• Magnetic drive through
AS-Interface output
• Solenoid power supply via via an external 24 VDC power supply
• AS-Interface LED status display
• AS-Interface M12 connector
• Thermoplastic enclosure
• Long life
• Protection class IP 67
• Connection of NC/NC contact or NC/NO contact combination
S
R
O R
Technical data
Standards:
Enclosure:
AS-Interface connection type:
Protection class:
AS-Interface operating voltage:
AS-Interface operating current:
AS-Interface specification:
Inputs:
Outputs:
Parameter bits:
Input module address:
Indications:
EMC rating:
Ambient temperature:
Storage and transport temperature:
EN 50295, EN 60947-5-1, EN 954-1 glass-fibre reinforced thermoplastic, self-extinguishing
(see ordering data)
IP 67
26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
) 50 mA
Profile S-7.B
IO-Code
ID-Code
ID-Code2
0x7
0xB
0xE
Contact Status
1 on
1 off
2
2 on off
D0/D1 = dynamic code transmission
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
A0 Solenoid control
A1... A3 not used
P0 … P3 not used default on address 0, programmable via the AS-Interface Master
AS-Interface: or Hand-held programming device supply voltage green LED, communication red LED, blinking = cross-wire short
Enabling status: LED1/contact1, yellow/contact2 conforming to EMC Directive
– 25 °C … + 55 ºC
– 25 °C … + 85 ºC
Approvals
F C D
C
Ordering details
AST
➀➁
-AS
➂➃
No. Replace Description
➀
➁
➂
➃
02
11
ST
L
2
4
6
ST
1 NC/1 NC
1 NO/1 NC
M12 connector
Cable (2m)
2 x 2-single conductors
(2 safety inputs)
1 x 4-single conductors
(2 safety inputs)
1 x 6-single conductors
(2 safety inputs and
1 semiconductor output)
M12 connector with
2m cable (2 x 2 or 1 x 4)
2
1
Note
4
3
M12 connector:
1: AS-Interface +
2: Aux – (6) (AST...6)
3: AS-Interface –
4: Aux + (6) (AST...6)
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
Note
• The wiring diagram is shown with guard doors closed and in de-energised condition.
Wiring diagram
• Monitoring a sliding guard door using two position switches with safety function.
The NC contact must have positive break when the guard door is opened.
• The module AST...AS is monitored by the
AS-Interface. The locking solenoid is powered by an external power supply.
Connection to the AS-Interface and the auxiliary power is made via a single M12 connector or via a 4-pole connecting cable.
• The necessary solenoid supply voltage is provided externally (auxiliary power).
• An internal output controls the solenoid operation. Depending on the interlocking device, output bit A0 locks or unlocks the actuator. Output bit A0 has the same address as the safety inputs.
bn bu bn bu
AST
02
AS 02
AS-i
13 14 21 22 bn bu wh bk
AZM 170-11z
A1 A2 rd gy
24 V DC
AST
11
AS 06
AS-i
S
R
O R
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
15
AS-Interface Safety at Work
BNS 16 AS
M 12
39
17
9
52
M 12
40
• Safety sensor
• Integrated AS-Interface
• AS-Interface LED status display
• Available with M12 plug-in connetor and pre-wired cable
• Thermoplastic enclosure
• Coded actuator
• Long life, no mechanical wear
• Intensitive to transverse misalignment
• Concealed mounting possible
• Intensitive to soiling
• Protection class IP 67
M20 x 1,5
S
Technical data
Standards:
Enclosure:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced thermoplastic, self-extinguishing
AS-Interface connection type:
Protection class:
AS-Interface operating voltage: connector M12 x 1
IP 67
26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification:
) 100 mA
Profile: S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code2: 0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code transmission
1
2 off on
2 off
Parameter bits:
D2/D3 = static code “00”
P0 … P3 not used
Input module address: Default on address 0
Indications:
AS-Interface:
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
Enabling status: voltage LED green, communication LED red
LED yellow
Mode of operation:
Sao:
Sar:
Repeat accuracy R:
Switching frequency f:
Actuating magnet:
EMC rating: magnetic
8 mm
18 mm
) 0,1 x Sao
< 1 Hz
BPS 16, coded conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
System components
20
60
40
Actuating magnet BPS 16
Actuating planes
¤ 5,5
R
O R
Approvals
F C D AE-i
Ordering details
BNS 16
➀
-AS
➁
No. Replace Description
➀
ST1
ST2
ST3
➁
V
D
Connector (middle)
Connector (right)
Connector (left)
Actuating planes: front side cover-side
2
1
Note
4
3
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
Ordering details
Actuating magnet
Actuators must be ordered separately.
BPS 16
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
System components System components
AS-i
+
AS-i
-
Aux
+
Aux
-
IDC connector (M12 outlet)
5 2
Aux -
4
Aux +
3
AS-i -
1
AS-i +
Passive connection module (M12 outlet)
IDC connector (screw outlet)
M 5
34
50
64
Terminal mounting H 30
S
R
O R
Ordering details
IDC connector (M12 outlet)
IDC connector (screw outlet)
Terminal mounting H 30
Ordering details
Passive connection module (M12 outlet)
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
17
AS-Interface Safety at Work
S
R
O R
ASU command devices
23,5 75
• Emergency-Stop button
• Compact embeddable command devices with ASU adapter box
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector,
IDC connector
• Miscellanous positioning parts
(metal, plastic)
• Mounting hole 22.3 mm
(to EN 50 007)
• Protection class IP 65 (from front)
Ø 38,5
38
Approvals
F
C
Ordering details
EFP
➀
-AS
➁
➂
DRZ 40 RT
Contact block
Actuating element
No. Replace Description
➀
➁
➂
ST
DT
ME
30
330
E
K
M12 connector
Flat cable connection (DC) optional: 2 m cable, cable gland, flying lead
1 NC
2 NC
Metal actuating element
Plastic actuating element
Technical data Technical data
Standards:
Enclosure:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced polyamide nylon, self-extinguishing
AS-Interface connection type:
Protection class:
(see ordering data)
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification:
) 50 mA
Profile
IO-Code
ID-Code
ID-Code2
S-7.B
0x7
0xB
0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code
1
2 off on transmission
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
P0 … P3 not used
2 off
Parameter bits:
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Resistance to shock: 110 g/4 ms…30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration:
* 20 g / 10 …200 Hz
(for actuating heads with higher respectively lower weight)
EMC rating: conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Actuating elements
Al-metal actuating element:
Resistance to shock:
Resistance to vibration: max. 15 g / 22 ms*
(temporary data) max. 0.35 mm,
0 … 150 Hz
Plastic actuating element:
Resistance to shock: max. 15 g / 22 ms*
Resistance to vibration:
(temporary data) max. 0.35 mm,
0 … 150 Hz
* preliminary data
Note
Addressing through flat cable connection or through M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
2
1
Flat cable connection:
1: AS-i +
2: AS-i –
Note
Mounting
One-hole fixation 22.3 mm + 0.4 mm to
EN 50 007 (a tail cut-out as displacement protection is not required for Elan devices)
The positioning parts are not included in delivery.
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
S
R
O R
ASU command devices Technical data
23,5 75
Ø 29,5 (29,8)
Ø 22 (25)
• Push button
• Compact embeddable command devices with ASU adapter box
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector,
IDC connector
• Miscellanous positioning parts
(metal, plastic)
• Mounting hole 22.3 mm
(to EN 50 007)
• Protection class IP 65 (from front)
38
Standards: EN 50295
EN 60947-5-1
EN 954-1
Enclosure:
AS-Interface connection type:
Protection class: glass-fibre reinforced polyamide nylon, self-extinguishing
(see ordering data)
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
) 50 mA
AS-Interface specification: Profile
IO-Code
S-7.B
0x7
ID-Code
ID-Code2
0xB
0xE
Inputs:
Contact Status
1 on
1 off
D0/D1 = dynamic code transmission
D0/D1 = static code “00”
2 on
2 off
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
Parameter bits: P0 … P3 not used
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Resistance to shock: 110 g/4 ms…30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration:
* 20 g / 10 …200 Hz
(for actuating heads with
EMC rating: higher respectively lower weight) conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Approvals
F
C
Ordering details
EFP
➀
-AS
➁
➂
DT
➃
Contact block
Actuating element
No. Replace Description
➀
➁
➂
➃
ST
DT
ME
03
033
E
K
GN*
SW*
BL*
M12 connector
Flat cable connection (DC) optional: 2 m cable, cable gland, flying lead
1 NO
2 NO
Metal actuating element
Plastic actuating element
Green push-button
Black push-button
Blue push-button
Other colours on request
Note
Addressing through flat cable connection or through M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
2
1
Flat cable connection:
1: AS-i +
2: AS-i –
Note
Mounting
One-hole fixation 22.3 mm + 0.4 mm to
EN 50 007 (a tail cut-out as displacement protection is not required for Elan devices)
The positioning parts are not included in delivery.
* Push-buttons in different colours available on request.
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
19
AS-Interface Safety at Work
S
R
O R
ASU command devices
23,5 75
Ø 29,5 (29,8)
Ø 22 (25)
• Illuminated push-button
• Compact embeddable command devices with ASU adapter box
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector,
IDC connector
• Miscellanous positioning parts
(metal, plastic)
• Mounting hole 22.3 mm
(to EN 50 007)
• Protection class IP 65 (from front)
38
Approvals
F
C
Ordering details
EFP
➀
-AS
➁
➂
DL
➃
Contact block
Actuating element
No. Replace Description
➀
➁
➂
➃
ST
DT
ME
03L
E
K
GN*
SW*
M12 connector
Flat cable connection (DC) optional: 2 m cable, cable gland, flying lead
1 NO
Metal actuating element
Plastic actuating element
Green illuminated push-button
Black illuminated push-button
Other colours on request
Technical data
Standards: EN 50295
EN 60947-5-1
EN 954-1
Enclosure:
AS-Interface connection type:
Protection class: glass-fibre reinforced polyamide nylon, self-extinguishing
(see ordering data)
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
) 50 mA, with illuminated pushbutton
) 70 mA
AS-Interface specification : Profile
IO-Code
ID-Code
S-7.B
0x7
0xB
ID-Code2 0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code
1
2 off on transmission
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
A0 Indicator lamp
2
Outputs: off
Parameter bits:
A1 ... A3 not used
P0 … P3 not used
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Resistance to shock: 110 g/4 ms…30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration: * 20 g / 10 …200 Hz
(for actuating heads with
EMC rating: higher respectively lower weight) conforming to
EMC Directive
Ambient temperature: – 25 °C … + 60 ºC
Storage and transport temp.: – 25 °C … + 85 ºC
Note
Addressing through flat cable connection or through M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
2
1
Flat cable connection:
1: AS-i +
2: AS-i –
Note
Mounting
One-hole fixation 22.3 mm + 0.4 mm to
EN 50 007 (a tail cut-out as displacement protection is not required for Elan devices)
The positioning parts are not included in delivery.
* Push-buttons in different colours available on request.
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
ASU command devices
• Other ASU command devices on request
Technical data
Standards: EN 50295
EN 60947-5-1
EN 954-1
Enclosure:
AS-Interface connection type:
Protection class: glass-fibre reinforced polyamide nylon, self-extinguishing
(see ordering data)
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
) 50 mA
AS-Interface specification : Profile
IO-Code
S-7.B
0x7
ID-Code
ID-Code2
0xB
0xE
Inputs:
Contact Status
1 on
1 off
D0/D1 = dynamic code transmission
D0/D1 = static code “00”
2 on
2 off
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
Parameter bits: P0 … P3 not used
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status:
Switching frequency:
LED yellow
3600/h
Resistance to shock: 30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration:
* 15 g / 10 ... 200 Hz
(for actuating heads with
EMC rating: higher respectively lower weight) conforming to
EMC Directive
Ambient temperature: – 25 °C … + 60 ºC
Storage and transport temp.: – 25 °C … + 85 ºC
Approvals
F
C
Ordering details on request
Note
Addressing through flat cable connection or through M12 connector.
1
1 4
2 3
2
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
Flat cable connection:
1: AS-i +
2: AS-i –
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
S
R
O R
Phone: 905-738-6688
21
AS-Interface Safety at Work
S
R
O R
ASU position switches
23,5
30
22
20
35
75
7,8 10
20
23,7
• Position switch with offset roller lever
• Compact position switches with ASU-adapter box
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector,
IDC connector
• Mounting details to EN 50 047
• Positive break contacts
• Protection class IP 65 (from front)
38
Approvals
F
C
Ordering details
SESR
➀ ➁
-AS
➂
No. Replace Description
➀
➁
➂
11
13
ST
DT
ME
110
Metal roller
Plastic roller
M12 connector
Flat cable connection (DC) optional: 2 m cable, cable gland, flying lead
2 NC
Technical data Contact variants
Standards:
Enclosure:
Design:
AS-Interface connection type:
Protection class:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced polyamide nylon, self-extinguishing fixings to EN 50047
(see ordering data)
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification :
) 50 mA
Profile
IO-Code
ID-Code
ID-Code2
S-7.B
0x7
0xB
0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code
1
2 off on transmission
D0/D1 = static code “00”
D2/D3 = dynamic code
2 off transmission
D2/D3 = static code “00”
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Switching frequency: 3600/h
Resistance to shock: 30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration: * 15 g / 10 ... 200 Hz
(for actuating heads with
EMC rating: higher respectively lower weight) conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Switching angle
0 3 6
Note
Addressing through flat cable connection or through M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
2
1
Flat cable connection:
1: AS-i +
2: AS-i –
Note
General use
Actuating angle:
Actuating direction of max. 30° the actuating heads: 4 x 90° repositioned
Repeat accuracy of switching points for plastic rollers: for metal rollers: at the plunger:
Plastic roller
Actuating speed (normally):
Metal roller
± 0,2 mm
± 0,1 mm
± 0,01 mm
> 30m/min.
Actuating speed
(temperatures > 50°C):
Mounting:
Recommended: max. 30 m/min cylindric screws M4 x 25
ISC 1207 (DIN 84), spring washer A4 DIN 137
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
S
R
O R
ASU position switches Technical data Contact variants
23,5
30
22
20
35
75
7,8
20
43,5
10
23,7
38
• Position switches with vertical roller lever
• Compact position switches with ASU-adapter box
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector,
IDC connector
• Mounting details to EN 50 047
• Positive break contacts
• Protection class IP 65 (from front)
5
Approvals
F
C
Ordering details
SESH
➀ ➁
-AS
➂
No. Replace Description
➀
➁
➂
15
17
ST
DT
ME
110
Metal roller
Plastic roller
M12 connector
Flat cable connection (DC) optional: 2 m cable, cable gland, flying lead
2 NC
Standards:
Enclosure:
Design:
AS-Interface connection type:
Protection class:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced polyamide nylon, self-extinguishing fixings to EN 50047 connector M12 x 1
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification :
) 50 mA
Profile
IO-Code
ID-Code
ID-Code2
S-7.B
0x7
0xB
0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code
1
2 off on transmission
D0/D1 = static code “00”
D2/D3 = dynamic code
2 off transmission
D2/D3 = static code “00”
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Switching frequency: 3600/h
Resistance to shock: 30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration: * 15 g / 10 ... 200 Hz
(for actuating heads with
EMC rating: higher respectively lower weight) conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Switching angle
60° 10° 0° 10° 60°
Note
Addressing through flat cable connection or through M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
2
1
Flat cable connection:
1: AS-i +
2: AS-i –
Note
General use
Actuating angle:
Actuating direction of max. 30° the actuating heads: 4 x 90° repositioned
Repeat accuracy of switching points for plastic rollers: for metal rollers: at the plunger:
Plastic roller
Actuating speed (normally):
Metal roller
± 0,2 mm
± 0,1 mm
± 0,01 mm
> 30m/min.
Actuating speed
(temperatures > 50°C):
Mounting:
Recommended: max. 30 m/min cylindric screws M4 x 25
ISC 1207 (DIN 84), spring washer A4 DIN 137
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
23
AS-Interface Safety at Work
S
R
O R
ASU position switches
23,5
30
22
20
35
75
7,8
20
10
23,7
38
• Position switches with vertical plunger
• Compact position switches with ASU-adapter box
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector,
IDC connector
• Mounting details to EN 50 047
• Positive break contacts
• Protection class IP 65 (from front)
Approvals
F
C
Ordering details
SES
➀
-AS
➁
No. Replace Description
➀
➁
ST
DT
ME
110
M12 connector
Flat cable connection (DC) optional: 2 m cable, cable gland, flying lead
2 NC
Technical data Contact variants
Standards:
Enclosure:
Design:
AS-Interface connection type:
Protection class:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced polyamide nylon, self-extinguishing fixings to EN 50047 connector M12 x 1
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification :
) 50 mA
Profile
IO-Code
ID-Code
ID-Code2
S-7.B
0x7
0xB
0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code
1
2 off on transmission
D0/D1 = static code “00”
D2/D3 = dynamic code
2 off transmission
D2/D3 = static code “00”
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Switching frequency: 3600/h
Resistance to shock: 30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration: * 15 g / 10 ... 200 Hz
(for actuating heads with
EMC rating: higher respectively lower weight) conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Switching angle
0 3 6
Note
Addressing through flat cable connection or through M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
2
1
Flat cable connection:
1: AS-i +
2: AS-i –
Note
General use
Actuating angle:
Actuating direction of max. 30° the actuating heads: 4 x 90° repositioned
Repeat accuracy of switching points for plastic rollers: for metal rollers: at the plunger:
Plastic roller
Actuating speed (normally):
Metal roller
± 0,2 mm
± 0,1 mm
± 0,01 mm
> 30m/min.
Actuating speed
(temperatures > 50°C):
Mounting:
Recommended: max. 30 m/min cylindric screws M4 x 25
ISC 1207 (DIN 84), spring washer A4 DIN 137
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
S
R
O R
ASU position switches Technical data Contact variants
23,5
30
22
Ø 10
20
35
75
7,8 10
20
4
23,7
38
• Position switches with vertical roller plunger
• Compact position switches with ASU-adapter box
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector,
IDC connector
• Mounting details to EN 50 047
• Positive break contacts
• Protection class IP 65 (from front)
Approvals
F
C
Ordering details
SESB
➀ ➁
-AS
➂
No. Replace Description
➀
➁
➂
31
33
ST
DT
ME
110
Metal roller
Plastic roller
M12 connector
Flat cable connection (DC) optional: 2 m cable, cable gland, flying lead
2 NC
Standards:
Enclosure:
Design:
AS-Interface connection type:
Protection class:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced polyamide nylon, self-extinguishing fixings to EN 50047 connector M12 x 1
IP 65 (front)
IP 20 (rear of the front plate)
AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
AS-Interface specification :
) 50 mA
Profile
IO-Code
ID-Code
ID-Code2
S-7.B
0x7
0xB
0xE
Inputs:
Contact Status
1 on D0/D1 = dynamic code
1
2 off on transmission
D0/D1 = static code “00”
D2/D3 = dynamic code
2 off transmission
D2/D3 = static code “00”
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status: LED yellow
Switching frequency: 3600/h
Resistance to shock: 30 g/18 ms, no bouncing
(for actuating heads with higher respectively lower weight)
Resistance to vibration: * 15 g / 10 ... 200 Hz
(for actuating heads with
EMC rating: higher respectively lower weight) conforming to
EMC Directive
– 25 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
Switching angle
0 3 6
Note
Addressing through flat cable connection or through M12 connector.
2
1
3
4
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
2
1
Flat cable connection:
1: AS-i +
2: AS-i –
Note
General use
Actuating angle:
Actuating direction of max. 30° the actuating heads: 4 x 90° repositioned
Repeat accuracy of switching points for plastic rollers: for metal rollers: at the plunger:
Plastic roller
Actuating speed (normally):
Metal roller
± 0,2 mm
± 0,1 mm
± 0,01 mm
> 30m/min.
Actuating speed
(temperatures > 50°C):
Mounting:
Recommended: max. 30 m/min cylindric screws M4 x 25
ISC 1207 (DIN 84), spring washer A4 DIN 137
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
25
AS-Interface Safety at Work
BNS 33 AS
4,5
ø 5
88
78
LED
2000
• Safety sensor
• Integrated AS-Interface
• AS-Interface LED status display
• Available with M12 plug-in connetor and pre-wired cable
• Thermoplastic enclosure
• Coded actuator
• Long life, no mechanical wear
• Intensitive to transverse misalignment
• Concealed mounting possible
• Intensitive to soiling
• Protection class IP 67
S
Technical data
Standards:
Enclosure:
EN 50295
EN 60947-5-1
EN 954-1 glass-fibre reinforced thermoplastic
AS-Interface connection type:
Cable section:
Protection class:
AS-Interface cable LSYY (black)
2 x 0.24 mm
2
IP 67 operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
AS-Interface operating current:
) 50 mA
AS-Interface specification: Profile: S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code2: 0xE
Inputs:
Contact Status
1 on
1
2 off on
D0/D1 = dynamic code transmission
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00” 2 off
Parameter bits: P0 … P3 not used
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green, communication LED red
Enabling status:
Mode of operation:
S ao
:
S ar
:
Actuating magnet:
EMC rating:
LED yellow magnetic
5 mm
15 mm
BPS 33, coded conforming to
EMC Directive
– 25 °C … + 70 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
System components
4,5
88
78
Actuating magnet BPS 33
ø 5
Spacer BN 31/33
78
88
R
O R
Approvals
F C D
C
Ordering details
BNS 33
➀
-AS
No. Replace Description
➀
STG
STW
2 m cable
2 m cable with straight plug M12
2 m cable with angled plug M12
Note
A separate address jack is not available as an option. The addressing must take place via the cable end or the M12 connector.
1 4
Ordering details
Actuating magnet
Spacer
BPS 33
BN 31/33
The actuators for the magnetic safety sensors must be ordered separately.
2 3
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
TG...-A
150
8,5
200
• Door handle switch
• Integrated AS-Interface
• AS-Interface LED status display
• AS-Interface M12 connector
• Enabling button
• Coloured signal LEDs (optional)
• Protection class IP 65
4
Technical data
Standards: EN 50295
EN 60947-5-1
EN 954-1
PA + POM Enclosure:
AS-Interface connection type:
Protection class:
AS-Interface operating voltage: connector M12 x 1
IP 65 reverse-polarity proof
AS-Interface operating current:
) 50 mA
AS-Interface specification : Profile S-B.A
IO-Code 0xB
ID-Code 0xA
ID-Code2 0xE
Outputs:
26.5 ... 31.6 VDC, via AS-Interface,
Inputs:
Data bits
D0
D1
Function
LED 1 (G)
LED 2 (R)
Data bits
D2
Function
NO contact 1
D3 NO contact 2
(optional)
Input module address: default on address 0, programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green communication LED red
EMC rating: conforming to
EMC Directive
– 20 °C … + 60 ºC Ambient temperature:
Storage and transport temperature: – 25 °C … + 85 ºC
S
R
O R
Approvals
C D
C
Ordering details
TG-S GR xx-A
Further devices on request.
Note
A separate address jack is not available as an option. The addressing must take place via the cable end or the M12 connector.
1 4
2 3
M12 connector:
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
27
AS-Interface Safety at Work
ASF 2 CC
51
• Input module
• 2 safe inputs for mechanical contacts
• Cross-wire monitoring
• Cage clamp terminals for safety device connection
• LED function display
• IDC technology for
AS-Interface flat cable
• Protection class IP 67
66
102
80
S
R
O R
Technical data
Standards:
Enclosure:
AS-Interface connection type:
Cage clamp terminals:
AS-Interface operating voltage:
Protection class:
AS-Interface operating current:
Inputs:
Input signal:
AS-Interface specification:
Inputs:
Parameter bits:
Input module address:
Indications:
EMC rating:
Ambient temperature:
Storage and transport temperature:
1
1
2
2
EN 50295, EN 954-1 black
IDC to the flat cable AS-Interface max. 2,5 mm
2
(incl. conductor ferrules)
26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof
IP 67
< 70 mA
2 safe inputs for mechanical contacts, monitored for cross-wired circuit, cable length < 30 m
„S+1, S+2“: le < 10 mA, pulsed
Profile: S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code2: 0xE on off on off
D0/D1 = dynamic code transmission
D0/D1 = static code “00”
D2/D3 = dynamic code transmission
D2/D3 = static code “00”
P0
P1
P2
P3 not used default on address 0, programmable via the AS-Interface Master or Hand-held programming device
AS-Interface: not used not used not used
Switching condition: voltage LED green communication LED red
LED yellow conforming to EMC Directive
– 25 °C … + 60 ºC
– 25 °C … + 85 ºC
Approvals
F
C
Ordering details
ASF 2 CC
Note
The safe AS-Interface input module offers two universal safety relevant inputs for mechanical contacts. The safe switches are connected to cage-clamp terminals inside the module housing.
The signal voltage is supplied by the module itself.
The two safe input channels are cross-wire monitored
The base module is the electro-mechanical link between the AS-Interface flat cable and the user module (i.e. ASF 2CC).
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
Note
• The wiring diagram is shown with guard doors closed and in de-energised condition.
Wiring diagram
S+1 RES S-1 S-2 RES S+2
• Please note that for the correct use of the input module there must be two jumpers present (1+2 and 5+6, see electrical connection).
• Monitoring a sliding guard door using two position switches with safety function.
The NC contact must have positive break when the guard door is opened.
Inputs
2 1
S+1 RES S-1 S-2 RES S+2
Inputs
2 1
S
R
O R
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
29
AS-Interface Safety at Work
ASF KM1
¤ 9,6
26
80
36
Technical data
Standards:
U e
:
I e
:
AS-Interface specification:
AS-Interface connection type:
EN 50295
26,5 … 31,6 V
(according to AS-Interface specification) max. 2 A
EMS
Protection class:
2 flat cables
AS-Interface (IDC)
IP 67 to EN60529
Ambient temperature:
(only in combination with ASF 2 CC)
– 25 °C … + 60 ºC
Storage and transport temperature:
Special features:
– 25 °C … + 85 ºC
2 parallel cable channels for various T- and
Mounting:
Cross-junctions top hat section rail or screw mounting
36 26
¤ 5,8
• Base module
• Base module without address jack
• AS-Interface interface for user module
• Connection of AS-Interface flat cable
• Top hat section rail or screw mounting
S
R
O R
Approvals
Ordering details
ASF KM 1
Note
The base module is the electro-mechanical link between the AS-Interface flat cable and the user module (i.e. ASF 2CC).
Note
AS-i
AS-i
-
+
-
+
+ -
Contacts to module
Phone: 905-738-6688 www.ipecautomation.com
AS-Interface Safety at Work
ASF PM
↑
↓
• Hand-held programming device
• Addressing and Programming up to a maximum of 62 Slaves (A/B-Slaves)
• Read/write operation of slave data
• Displaying the IO-code
• Read/write operation of parameter data
• Displaying the address mode / ID-code
• Displaying the peripheral fault flags
• Determining the slave address
• Re-addressing with checking
• Slave connection is short-circuit and overload proof
• Mech. connection with the help of the universal adapter
• Battery charger included with delivery
S
R
O R
Technical data Note
Interface:
Operating device:
Operating duration:
Power supply:
Display:
Keyboard:
Protection class:
Ambient temperature:
Storage and transport temperature:
Dimensions:
AS-Interface, short-circuit- and overload-proof
230 VAC, plug-in charging unit, included in the delivery package
8 h or > 250 read/write cycles with fully charged batteries battery mode, charging time before use about 14 h
LC-display
5 keys, membrane keys
IP 20
0 °C … + 55 ºC
– 20 °C … + 55 ºC
80 x 34 x 214 mm
The LCD displays the address, the operating mode or an error code. The AS-Interface hand held programming device will be switched on by pressing the button “ADR”. It shuts down independently after about one minute when not in use.
• Pressing the “ADR” button causes the current slave address to be displayed
• The two keys “ B “ and “ ? “ can be used to select the programmable address from the address ring (i.e. 0 ...31, 0 ...31A, 0 ...31B)
• A short key stroke causes the page to turn stepwise, whereas holding down the key causes the pages to scroll continuously
(0.5s per address)
• Pressing the “PRG”-key causes the new address to be loaded into the slave
• The correct programmed address is automatically displayed after about 0.5s
• Holding down “ADR” and “PRG” simultaneously will automatically set back the slave address to zero
• Other key combinations do not trigger any further action
Approvals
C
Ordering details
ASF PM
Note
The LCD displays the address, the operating mode or an error code.
„ B “ button = increments slave address
„MODE“ button = changes the working mode
„ ? “ button = decrements slave address
„PRG“ button = programming of the new slave address
„ADR“ button = reading a slave address / switches on the device
Error messages
F1: AS-Interface overload
F2: Slave not found
F3: Programming error
F4: Destination address busy
F5: Zero address already occupied
F6: Standard slave found instead of an extended slave
F7: Extended slave found instead of a standard slave
F8: Reception error
LOBAT = Recharge batteries !
After the first indication approx. 30 read/write operation are still possible.
Load the accumulator only with the charger included within this delivery.
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688
31
Notizen
Phone: 905-738-6688 www.ipecautomation.com
More Details
Detailed technical information at: www.schmersal.com
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
German agencies
International agencies
Stammhaus
K.A. Schmersal GmbH
Industrielle Sicherheitsschaltsysteme
Postfach 24 02 63, 42232 Wuppertal
Möddinghofe 30
42279 Wuppertal
Telefon: +49-(0) 2 02-64 74-0
Telefax: +49-(0) 2 02-64 74-1 00
E-Mail: [email protected]
Internet: www.schmersal.com
01 Hamburg
K.A. Schmersal GmbH
Geschäftsstelle Hamburg
Zunftstraße 8
21244 Buchholz i.d.N.
Telefon: +49-(0) 41 81-9 22 0-0
Telefax: +49-(0) 41 81-9 22 0-20
E-Mail: [email protected]
02 Berlin
KSA Komponenten der Steuerungsund Automatisierungstechnik GmbH
Buchholzer Str. 62-65
13156 Berlin
Telefon: +49-(0) 30-47 48 24 00
Telefax: +49-(0) 30-47 48 24 05
E-Mail: [email protected]
Internet: www.ksa-gmbh.de
03 Hannover
ELTOP GmbH
Robert-Bosch-Str. 8
30989 Gehrden
Telefon: +49-(0) 51 08-92 73 20
Telefax: +49-(0) 51 08-92 73 21
E-Mail: [email protected]
Internet: www.eltop.de
04 Münster
K.A. Schmersal GmbH
Geschäftsstelle Münster
Am Vechte Ufer 22
48629 Metelen
Telefon: +49-(0) 25 56-9 38 30
Telefax: +49-(0) 25 56-93 83 73
E-Mail: [email protected]
05 Köln
Stollenwerk
Technisches Büro GmbH
Scheuermühlenstr. 40
51147 Köln
Telefon: +49-(0) 22 03-9 66 20-0
Telefax: +49-(0) 22 03-9 66 20-30
E-Mail: [email protected]
14 Ruhrgebiet
K W S Elektronik Schumacher
Saarstr. 19a
53919 Weilerswist
Telefon: +49-(0) 22 54-33 80
Telefax: +49-(0) 22 54-18 58
E-Mail: [email protected]
12 Siegen
Siegfried Klein
Elektro-Industrie-Vertretungen
Schloßblick 38
57074 Siegen
Telefon: +49-(0) 2 71-67 78
Telefax: +49-(0) 2 71-67 70
E-Mail: [email protected]
16 Frankfurt
K.A. Schmersal GmbH
Geschäftsstelle Frankfurt
Kilianstädter Straße 38
61137 Schöneck
Telefon: +49-(0) 61 87-9 09 56-0
Telefax: +49-(0) 61 87-9 09 56-6
E-Mail: [email protected]
Argentina - Argentinien
Hellermann Tyton
Monteagudo Street # 760
(B1672 AFP), Villa Lynch
1672 Buenos Aires
Telefon: +54-11-47 54 54 00
Telefax: +54-11-47 52 03 74
E-Mail: [email protected]
Australia - Australien
NHP Electrical Engineering
Products Pty. Ltd.
43 - 67 River Street
PO Box 199
Richmond 3121
Melbourne, Victoria
Telefon: +61-(0) 3-94 29 29 99
Telefax: +61-(0) 3-94 29 10 75
E-Mail: [email protected]
Internet: www.nhp.com.au
Austria - Österreich
AVS-Schmersal Vertriebs Ges. m.b.H.
Biróstraße 17
1232 Wien
Telefon: +43-(0) 1-6 10 28
Telefax: +43-(0) 1-6 10 28-1 30
E-Mail: [email protected]
Internet: www.avs-schmersal.co.at
Belgium - Belgien
Schmersal Belgium NV/SA
Nieuwlandlaan 16B
Industriezone B413
3200 Aarschot
Telefon: +32-(0) 16-57 16 18
Telefax: +32-(0) 16-57 16 20
E-Mail: [email protected]
Internet: www.schmersal.be
Brazil - Brasilien
ACE Schmersal
Eletroeletrônica Industrial Ltda.
Rodovia Boituva-Porto Feliz, Km 12
Vila Esplanada – CEP: 18550-000
Boituva – SP
Telefon: +55-(0) 15-32 63-98 66
Telefax: +55-(0) 15-32 63-98 90
E-Mail: [email protected]
Internet: www.aceschmersal.com.br
Chile - Chile
NDU Ingeneria
Santa Elisa 498
7160269 La Cisterna
Santiago de Chile
Telefon: +56-2-5 26-66 46
Telefax: +56-2-5 26-50 46
E-Mail: [email protected]
Colombia - Kolumbien
Cimpex Ltda.
Apartado Aereo 2429
Medellin
Telefon: +57-4-2 51-59 72
Telefon: +57-4-2 51-59 87
Telefax: +57-4-2 51-46 08
E-Mail: [email protected]
Costa Rica - Costa Rica
Euro-Tec, S.A.
Apartado Postal 477
1250 Escazú
San José
Telefon: +5 06-2 20-28 08
Telefon: +5 06-3 84-78 69
Telefax: +5 06-2 96-15 42
E-Mail: [email protected]
PR China - VR China
Schmersal Industrial Switchgear Co. Ltd.
Central Plaza 1001
Huang Pi Bei Road 227
200003 Shanghai
Telefon: +86-21-63 75 82 87
Telefax: +86-21-63 75 82 97
E-Mail: [email protected]
Internet: www.schmersal.com.cn
Czech Republic -
Tschechische Rebublik
Mercom Componenta spol. s.r.o.
Ruská 67
100 00 Praha 10
Telefon: +4 20-(0) 2-67 31 46 40
Telefon: +4 20-(0) 2-67 31 46 41
Telefax: +4 20-(0) 2-71 73 32 11
E-Mail: [email protected]
Denmark - Dänemark
Schmersal Danmark A/S
Lindegårdsvej 17A
2920 Charlottenlund
Telefon: +45-70 20 90 27
Telefax: +45-70 20 90 37
E-Mail: [email protected]
Internet: www.schmersal.dk
Finland - Finnland
Advancetec Oy
Malminkaari 10B
PO Box 149
00701 Helsinki
Telefon: +3 58-(0) 9-3 50 52 60
Telefax: +3 58-(0) 9-35 05 26 60
E-Mail: [email protected]
Internet: www.advancetec.fi
France - Frankreich
Automatisme et Contrôle
8, rue Raoul Follereau, BP 18
38180 Seyssins
Telefon: +33-4 76 84 23 20
Telefax: +33-4 76 48 34 22
E-Mail: [email protected]
Internet: www.automatisme-et-controle.fr
Greece - Griechenland
Kalamarakis Sapounas S.A.
Ionias & Neromilou
PO Box 46566
13671 Chamomilos Acharnes
Athens
Telefon: +30-(0) 1-2 40 60 00-6
Telefax: +30-(0) 1-2 40 60 07
E-Mail: [email protected]
Honduras - Honduras
Lusitana Int´I,
Distribuciones - Represantaciones
Apdo. Postal # 783
21105 San Pedro Sula
Telefon: +5 04-6 69-14 46
Telefax: +5 04-6 69-14 46
Hungary - Ungarn
NTK Ipari-Elektronikai és
Kereskedelmi Kft
Mészáros L. u. 5.
9023 Györ
Telefon: +36-(0) 96-52 32 68
Telefax: +36-(0) 96-43 00 11
E-Mail: [email protected]
Internet: www.ntk-kft.hu
India - Indien
Arihant Electricals
24/4866, Ansari Road
Darya Ganj, Sheel Tara House
102222 New Delhi
Telefon: +91-11-23 26 21 76
Telefax: +91-11-23 27 35 54
E-Mail: [email protected]
Phone: 905-738-6688 www.ipecautomation.com
08 Saarland
Herbert Neundörfer
Werksvertretungen
Saargemünder Str. 68a
66130 Güdingen
Telefon: +49-(0) 6 81-87 54 54
Telefax: +49-(0) 6 81-87 54 53
E-Mail: [email protected]
Internet: www.herbert-neundoerfer.de
10/
15
Bayern Süd
Ing. Adolf Müller GmbH
Industrievertretungen
Elly-Staegmeyr-Str. 15
80999 München
Telefon: +49-(0) 89-8 12 60 44
Telefax: +49-(0) 89-8 12 69 25
E-Mail: [email protected]
19 Leipzig
K.A. Schmersal GmbH
Geschäftsstelle Leipzig
Nonnenstraße 11c
04229 Leipzig
Telefon: +49-(0) 3 41-4 87 34 50
Telefax: +49-(0) 3 41-4 87 34 51
E-Mail: [email protected]
11 Stuttgart
Gerhard Schützinger
Labor-Schütz GmbH
Industrievertretungen
Postfach 81 05 69, 70522 Stuttgart
Eichwiesenring 6
70567 Stuttgart
Telefon: +49-(0) 7 11-7 15 46-0
Telefax: +49-(0) 7 11-7 15 46-18
E-Mail: [email protected]
Internet: www.schuetzinger.de
09 Bayern Nord
K.A. Schmersal GmbH
Geschäftsstelle Nürnberg
Beethovenstr. 14
91074 Herzogenaurach
Telefon: +49-(0) 91 32-73 70 00
Telefax: +49-(0) 91 32-73 48 44
E-Mail: [email protected]
Indonesia - Indonesien
P.T. Wiguna Sumber Sejahtera
JI. Kesehatan Raya No. 36
Jakarta Pusat 10160
Telefon: +62-(0) 21-34 83 42 30
Telefax: +62-(0) 21-34 83 42 31
E-Mail: [email protected]
Internet: www.wiguna.co.id
Israel - Israel
A.U. Shay Ltd.
23 Imber St. Kiriat. Arieh.
P.O. Box 10049
Petach Tikva
Telefon: +9 72-3-9 23 36 01
Telefax: +9 72-3-9 23 46 01
E-Mail: [email protected]
Italy - Italien
Schmersal Italia s.r.l.
Via Molino Vecchio, 206
25010 Borgosatollo, Brescia
Telefon: +39-0 30-2 50 74 11
Telefax: +39-0 30-2 50 74 31
E-Mail: [email protected]
Internet: www.schmersal.it
Japan - Japan
Elan-Schmersal Japan Branch Office
3-39-8 Shoan, Suginami-ku,
Tokyo 167-0054
Telefon: +81-(03)-3247-0519
Telefax: +81-(03)-3247-0537
E-Mail: [email protected]
Korea - Korea
MEC Manhani Electric Co. Ltd.
576-8, Bisan-2dong
Dongan-Ku
Anyang-City
Kyungi-Do 431-821
Telefon: +82-(0) 31-4 63-33 00
Telefax: +82-(0) 31-4 63-33 98
Telefax: +82-(0) 31-4 63-33 99
E-Mail: [email protected]
Malaysia - Malaysia
Ingermark (M) SDN.BHD
No. 29, Jalan KPK 1/8
Kawasan Perindustrian Kundang
48020 Rawang, Selangor Darul Ehsan
Telefon: +6 03-60-34 27 88
Telefax: +6 03-60-34 21 88
E-Mail: [email protected]
Netherlands - Niederlande
Hatenboer Elektro BV
Postbus 200
2170 AE Sassenheim
Telefon: +31-(0) 2 52-21 90 12
Telefax: +31-(0) 2 52-23 29 38
E-Mail: [email protected]
Internet: www.hatenboer.com
Norway - Norwegen
Schmersal Nordiske
Hoffsveien 92
0377 Oslo
Telefon: +47-22 06 00 70
Telefax: +47-22 06 00 80
E-Mail: [email protected]
Internet: www.schmersal.se
Paraguay - Paraguay
Brasguay S.R.L.
Ruta Internacional, 07, Km1
Mingua Guazu
Telefon: +5 95-6 44-2 04 18
Telefax: +5 95-6 44-2 05 77
E-Mail: [email protected]
Poland - Polen
Schmersal - Polska Sp.j.
ul. Kremowa 65A
02-969 Warszawa
Telefon: +48-(0) 22-8 16 85 78
Telefon: +48-(0) 22-8 16 85 79
Telefax: +48-(0) 22-8 16 85 34
E-Mail: [email protected]
Portugal - Portugal
K.A. Schmersal GmbH
Sucursal em Portugal
Av. das Descobertas, 15-2° D
Quinta do Infantado
2670-383 Loures
Telefon: +3 51-21-9 83 92 83
Telefax: +3 51-21-9 83 19 37
E-Mail: [email protected]
Internet: www.schmersal.pt
Serbia/Montenegro - Serbien
Tipteh d.o.o. Beograd
Bulevar AVNOJ-a45D, lokal 18
11070 Novi Beograd,
Serbien / Montenegro
Telefon: +3 81-11-3 13 10 57
Telefax: +3 81-11-3 01 83 26
E-mail: [email protected]
Internet: www.tipteh.co.yu
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
05
04
14
12
16
08
11
03
01
09
10/15
19
02
Singapore - Singapur
Tong Sim Marine & Electric Co.
46 Kaki Bukit Crescent
Kaki Bukit Techpark 1
Singapore 416269
Telefon: +65-67 43 31 77
Telefax: +65-67 45 37 00
E-Mail: [email protected]
Slovenia - Slowenien
Tipteh d.o.o.
Ulica Ivana Roba 21
1000 Ljubljana
Telefon: +386-1-2 00 51 50
Telefax: +386-1-2 00 51 51
E-Mail: [email protected]
Spain - Spanien
Forn Valls S.A.
c/Milanesado, 2 tda
08017 Barcelona
Telefon: +34-9 32-03 41 33
Telefon: +34-9 32-04 05 44
Telefax: +34-9 32-05 54 67
E-Mail: [email protected]
Internet: www.fornvalls.com
South Africa - Südafrika
A+A Dynamic Distributors (Pty) Ltd.
3 Ruarch Street
Park Central Johannesburg
PO Box 38247
2016 Booysens
Telefon: +27-11-4 93 50 22
Telefax: +27-11-4 93 07 60
E-Mail: [email protected]
Sweden - Schweden
Schmersal Nordiska AB
Klockarns Väg 1
43533 Mölnlycke
Telefon: +46-(0) 31-3 38 35 00
Telefax: +46-(0) 31-3 38 35 35
E-Mail: [email protected]
Internet: www.schmersal.se
Switzerland - Schweiz
Schmersal Schweiz AG
Freilagerstr. 25
8047 Zürich
Telefon: +41-(0) 43-3 11 22 33
Telefax: +41-(0) 43-3 11 22 44
E-Mail: [email protected]
Taiwan - Taiwan
Leader Camel Enterprise Co., Ltd.
No. 453-7, Pei Tun Rd.
Taichung, Taiwan
Telefon: +886-4-22 41 32 92
Telefax: +886-4-22 41 29 23
E-Mail: [email protected]
Internet: www.leadercamel.com.tw
Thailand - Thailand
M. F. P. Engineering Co. Ltd.
64-66 Buranasart Road
Sanchaoporsva
Bangkok 10200
Telefon: +66-2-2 26 44 00
Telefax: +66-2-2 25 67 68
E-Mail: [email protected]
Turkey - Türkei
BETA Elektrik Sanayi Ve Ticaret
Günes Han. No. 66/7
80020 Karaköy / ISTANBUL
Telefon: +90-212-253 99 14
+90-212-253 99 15
Telefax: +90-212-253 54 56
E-Mail: [email protected]
Internet: www.betaelektrik.com
UK - Großbritannien
Schmersal UK Ltd.
Unit 1, Beauchamp Business Centre
Enigma Park
Worcs WR14 1GL, Malvern
Telefon: +44-(0) 16 84-57 19 80
Telefax: +44-(0) 16 84-56 02 73
E-Mail: [email protected]
Internet: www.schmersal.co.uk
USA - USA
Schmersal Inc.
660 White Plains Road
Suite 160
Tarrytown, NY 10591
Telefon: +1-(0) 9 14-3 47-47 75
Telefax: +1-(0) 9 14-3 47-15 67
E-Mail: [email protected]
Internet: www.schmersalusa.com
Venezuela - Venezuela
Petro System C.A.
Av. 12 entre 7 y 8 Transv. Qta. Roysbel
Altamira No. 3405
Caracas
Telefon: +58-212-9 63 53 46
+58-212-9 61 40 76
E-Mail: [email protected]
Phone: 905-738-6688
35
K.A. Schmersal GmbH
Industrielle Sicherheitsschaltsysteme
Möddinghofe 30
D-42279 Wuppertal
Postfach 24 02 63
D-42232 Wuppertal
Telefon +49 - (0)2 02 - 64 74 - 0
Telefax +49 - (0)2 02 - 64 74 - 1 00
E-Mail [email protected]
Internet http://www.schmersal.com
IPEC Industrial Controls Ltd.
17-109 Fernstaff Court, Concord, Ont. L4K 3M1
Phone: 905-738-6688 www.ipecautomation.com
advertisement