DIGITAL MULTIMETERS Hand-held Digital Multimeters DL-90 SERIES Hand-held Digital Multimeters DL-91 DL-92 DL-94 DL-97 OUTLINE (Accuracy ±0.5%) These four digital multimeters of the DL-90 Series have been designed to meet the diversifying needs users have for multimeters. Some of the most advanced functions incorporated in these models include the auto power-OFF function (which prevents wasting of battery power even if you forget to switch the power off) and current input connection alarm function which generates an alarm buzzer sound if you attempt to measure voltage while a test lead is left connected to the current input. An analog bar display is provided together with a digital display so the measurements can be identified a glance. Naturally, all models offer the basic measurement modes including DC voltage, AC voltage, DC current, AC current, resistance, diode checking and circuit continuity checking. Hand-held Digital Multimeters (Accuracy ±0.3%) Hand-held Digital Multimeters (Accuracy ±0.1%) Hand-held Digital Multimeters (Accuracy ±0.06%) DL-91 DL-92 182 DIGITAL MULTIMETERS DL-90 SERIES DL-91 FEATURES DL-92 FEATURES 3200 Full-Scale Digital Display plus Analog Bar Graph A 7-segment LCD display and a 32-segment bar graph display are provided. 3999 Full-Scale Digital Display plus Analog Bar Graph A 7-segment LCD display and a 40-segment bar graph display are provided. Versatile Measurement Modes All fundamental measurements are available, including: DC V, AC V, DC A, AC A, Ω as well as diode checking and continuity testing modes. Versatile Measurement Modes In addition to the basic measurements including DC V, AC V, DC A, AC A, Ω and plus diode checking and continuity testing modes, frequency measurement and capacity measurement modes are also available. Auto Power-OFF The auto power-OFF circuit prevents wasteful consumption of batter y power even when you forget to switch power off after measurement. Auto Power-OFF The auto power-OFF circuit prevents wasteful consumption of batter y power even when you forget to switch power off after measurement. In addition, it is also possible to defeat this circuit. Auto/Manual Ranging Switchable The measurement ranges in the DC V, AC V , Ω and measurements can be switched either automatically or manually. Auto/Manual Ranging Switchable The measurement ranges in the DC V, AC V, Ω and measurements can be switched either automatically or manually. Data Hold This function stops measurement temporarily and maintains the previously-measured value on the display. Battery Low Indication When the voltage of the built-in batteries drops, the battery mark blinks to alert you. Relative Computations This function calculates the difference from a reference value so that, for example, it can eliminate the input lead resistance during resistance measurement. Data Storage/Recall Measured data can be stored or recalled in memory together with the measuring units. [Common Features to DL-91] ● Data Hold ● Battery Low Indication ● Current Input Connection Alarm DL-94 DL-97 183 DIGITAL MULTIMETERS Current Input Connection Alarm When current measurement is switched to voltage measurement and, if the test lead used is left connected to the current input, hazard will occur because the measurement object is shor tcircuited at the moment the voltage measurement is started. To prevent this, a buzzer beeps when a test is lead is connected to the current input in measurement modes other than the current measurement modes. DL-90 SER ES Maximum and Minimum Data Memory The maximum and minimum values are stored in memor y. A buzzer beeps every time one of these values is updated. DIGITAL MULTIMETERS DL-94 FEATURES DL-97 FEATURES 5000 Full-Scale Digital Display plus Analog Bar Graph A 7-segment LCD display and a 50-segment bar graph display are provided. Back-lighted LCD Display The back light can be turned on to allow easy checking of the measured values even under low light. Versatile Measurement Modes In addition to the basic measurements including DC V, AC V, DC A, AC A, Ω and plus diode checking and continuity testing modes, the frequency measurement, capacity measurement and TTL logic level judgment modes are also available. Dual Display Two measurement value display sections are provided so it is possible to display the voltage and frequency or the DC and AC components simultaneously. 4000/40000 Full-Scale Digital Display plus Analog Bar Graph A 7-segment LCD display and a 20-segment x 4 bar graph display are provided. The full scale can be switched to 40000 increasing the display resolution by 1 digit. True rms Measurement AC V measurement measures tr ue rms values in place of obtaining values by conversion from the average values. Auto power-OFF function The instrument enters sleep mode in 15 minutes and the power goes OFF automatically in 15 more minutes. The auto power-OFF function can also be defeated. Versatile Measurement Modes In addition to the basic measurements including DC V, AC V, DC A, AC A, Ω and plus diode checking and continuity testing modes, the frequency measurement, capacity measurement, duty cycle measurement, pulse duration measurement and temperature measurement modes are also available. It is also possible to measure AC in which DCs are superimposed. Maximum and Minimum Data Memory The maximum and minimum values are stored in memory and can be displayed. The elapsed time values at which these values are obtained are also displayed alternately. Average Value Computation The average value of measured values can be calculated and displayed. The elapsed time values are also displayed alternately. High Accuracy/True rms Measurement The accuracy is as high as ±0.6% of reading 3 digits with DC voltage measurement. The AC V and AC C measurement measures tr ue rms values in place of obtaining values by conversion from the average values. Relative Computations ( ∆, ∆/r) The ∆mode calculates the difference from a reference value and the ∆/r mode calculates the deviation when the reference value is assumed to be 100%. 1 msec Peak Hold The capability of capturing the waveform peak value makes it possible to calculate the crest factor when combined with the true rms measurement function. dBm Measurement The reference impedance can be selected from 20 selections between 4 and 1,200Ω in addition to 600Ω. Communications Function The optional OP-597 allows the DL-97 to interface with a computer through RS-232C and to store the data measured with it in the computer. TTL Logic Level Judgment This function displays the identified RHS level with ▲ and the RLS level with ▼. Square Wave Output The square wave frequency can be selected from 16 selections between 0.5 Hz and 4.8 kHz. The duty ratio is also variable between 1% and 99% in 1% steps. [Common Features to DL-91] ●Data Hold ●Current Input Connection Alarm Timer Function The timer can be set up to 99,999 seconds. The timer output is switched between four types and the TTL level makes it possible to be applied to a variety of applications. [Common Features to DL-94] ●Auto power-OFF. ●Auto/manual ranging switching. ●Maximum and minimum value memory (with recording time display). ●Average value computation (with elapsed time display). ●Relative computations. ●Data hold. ●Current input connection alarm. 184 DIGITAL MULTIMETERS DL-90 SERIES General Specifications DL-91 SPECIFICATIONS Measurement Functions DC Voltage (Auto/manual ranging) Range Resolution 320mV 100µV 3.2V 1mV 32V 10mV 320V 100mV 1000V 1V Accuracy Sampling Rate Input Impedance Display Maximum display Polarity display Approx. 1000MΩ Approx. 11MΩ ±(0.5% of rdg + 2dgt) Approx. 10MΩ Over-range display Computations Power-Save Function ±(0.6% of rdg + 4dgt) Maximum voltage: ±1000V DC, 750V AC rms Temperature/Humidity for characteristics in spec. Operating Temperature /Humidity Ranges Storage Temperature /Humidity Ranges Temperature Coefficient AC Voltage (Auto/manual ranging) Range Resolution Accuracy Input Impedance 50Hz-400Hz Approx. 11MΩ// 3.2V 1mV ±(1.5% of rdg + 5dgt) 50pF max. 32V 10mV 50Hz-1kHz Approx. 10MΩ// 320V 100mV ±(1.5% of rdg + 5dgt) 50pF max. 750V 1V Power source 50Hz-400Hz ±(1.5% of rdg + 5dgt) Battery Life Maximum voltage: ±1000V DC, 750V AC rms Average value detection, rms calibration Dimensions Weight Accessories DC Current (Manual ranging) Range Resolution 0.1µA 1µA 32mA 0.01mA 320mA 0.1mA 10A 10mA Voltage drop Input protection ±(1.5% of rdg + 3dgt) Complying Standards between terminals 630mA/250V 0.2V quick-blow fuse 2V 5 to 40℃, 70% RH or less − 10 to 55℃, 80% RH or less (without battery) Add 0.15×(Accuracy at 23±5℃)/℃ at 0 to 18 ℃ and 28℃ to 40 ℃ 1.5V DC (SUM-3/IEC R6/LR6 manganese battery or alkaline battery × 2) Approx. 1,000 hours (DC V measurement using manganese batteries) Approx. 77 (W)× 34 (H)× 162 (D) mm Approx. 290 g (including battery) Instruction manual (1), test lead set (1 set), batteries (IEC R6) (2) EN55011 (1991) CLASS B IEC801-2 (1991) 8kVAD IEC801-3 (1984) 3V/m IEC801-4 (1988) 1kV, 5/50 µs, 5kHz 0.2V 2V ±(2.0% of rdg+3dgt) 10A/250V 0.4V DL-90 SER ES 320µA 3200µA Accuracy DC voltage, AC voltage, DC current, AC current, resistance, diode check, continuity check Digital display: 2 times/sec Bar graph: 12.5 time/sec LCD display 3200 Automatic switching. “-” displayed with negative polarity. “OL” is displayed. HOLD (Data Hold) Auto power-OFF is activated in approx. 10 minutes later. 23℃, ±5℃, 75% RH or less DL-92 SPECIFICATIONS quick-blow fuse Range Resolution 320µA 0.1µA 3200µA 1µA 32mA 0.01mA 320mA 0.1mA 10A 10mA Accuracy 50Hz-1kHz Range Resolution Accuracy Input Impedance 400mV 100µV ±(0.3% of rdg + 2dgt) Approx. 100MΩ 4V 1mV 40V 10mV 2V 400V 100mV 0.2V 1000V 1V Voltage drop Input protection between terminals 630mA/250V 0.2V ±(2.5% of rdg + 5dgt) quick-blow fuse 2V 10A/250V Maximum voltage: ±1000V DC, 750V AC rms AC Voltage (Auto/manual ranging except for 400mV range) Average value detection, rms calibration Resistance Resolution 320Ω 0.1Ω Accuracy ±(1.2% of rdg + 4dgt) Measuring Current 0.4mA (Rx=10Ω) 3.2kΩ 1Ω 0.1mA (Rx=100Ω) 32kΩ 10Ω 0.01mA (Rx=1kΩ) 320kΩ 100Ω 3.2MΩ 1kΩ ±(1.8% of rdg + 4dgt) 0.1µA (Rx=100kΩ) 32MΩ 10kΩ ±(2.5% of rdg + 3dgt) 0.1µA (Rx=1MΩ) Open-circuit Voltage Approx. 1.35V Accuracy Input Impedance 100µV 50Hz-100Hz Approx. 100MΩ// ±(1.5% of rdg + 5dgt) 50pF 4V 1mV 50Hz-500Hz Approx. 10MΩ// 40V 10mV ±(1.0% of rdg + 5dgt) 50pF 400V 100mV 50Hz-1kHz Approx. 9.1MΩ// 750V 1V ±(1.5% of rdg + 5dgt) 50pF Range Accuracy ±(1.5% of rdg+3dgt) Measuring Current Approx. 0.4mA Measuring Voltage Approx. 3V Maximum voltage: 500V rms Resolution 4mA 1µA 40mA 10µA 400mA 0.1mA 10A 10mA Accuracy ±(1.0% of rdg + 2dgt) ±(1.5% of rdg + 3dgt) Average value detection, rms calibration Range Resolution Input protection Threshold level Open-circuit Voltage Built-in buzzer beeps at Approx. 0.4mA below approx. 20Ω Maximum voltage: 500V rms 185 Voltage drop between terminals 630mA/250V ≦600mV quick-blow fuse ≦1V 10A/250V quick-blow fuse Continuity test 0.1Ω Resolution DC Current (Manual ranging) Diode check 1mV Range 400mV Maximum voltage: ±1000V DC, 750V AC rms Average value detection, rms calibration 1µA (Rx=100kΩ) Maximum voltage: 500V rms Range Resolution Approx. 9.1MΩ ±(0.7% of rdg + 2dgt) 0.4V quick-blow fuse Range Approx. 10MΩ ±(0.5% of rdg + 2dgt) ≦600mV DIGITAL MULTIMETERS DC Voltage (Auto/manual ranging) AC Current (Manual ranging) DIGITAL MULTIMETERS AC Current (Manual ranging) Range Resolution 4mA 1µA 40mA 10µA 400mA 0.1mA 10A 10mA General Specifications Accuracy Input protection 50Hz-1kHz 630mA/250V ≦600mV ±(1.2% of rdg + 5dgt) quick-blow fuse ≦1V 50Hz-1kHz Measurement Functions Voltage drop between terminals 10A/250V Sampling Rate Display Maximum display Polarity display ≦600mV ±(2.0% of rdg + 5dgt) quick-blow fuse Average value detection, rms calibration Over-range display Computations Resistance (Automatic ranging) Range Resolution 400Ω Open-circuit Accuracy Measuring Current 0.1Ω ±(1.0% of rdg + 4dgt) Approx. 130µA Approx. 4kΩ 1Ω ±(0.7% of rdg + 3dgt) Approx. 100µA 0.4V 40kΩ 10Ω 400kΩ 100Ω 4MΩ 1kΩ ±(1.0% of rdg + 4dgt) Approx. 300nA 40MΩ 10kΩ ±(2.0% of rdg + 3dgt) Approx. 30nA Voltage Power-Save Function Temperature/Humidity for characteristics in spec. Operating Temperature /Humidity Ranges Storage Temperature /Humidity Ranges Temperature Coefficient Approx. 30µA Approx. 3µA Maximum voltage: 500V rms Frequency (Automatic ranging) Range Resolution 100Hz Accuracy Power source Input Minimum input Maximum sensitivity 0.01Hz ±(0.2% of rdg + 4dgt) 100mVrms 1000Hz 0.1Hz 10kHz 1Hz 100kHz 100Hz 1MHz 1kHz frequency Voltage 10Hz 500Vrms Battery Life but less than 200mVrms Dimensions Weight Accessories 10 6VHz Complying Standards Diode check Range Resolution 1mV Accuracy Measuring Current ±(1.0% of rdg+3dgt) Approx. 0.8mA Measuring Voltage DC voltage, AC voltage, DC current, AC current, resistance, frequency, static capacity, diode check, continuity check, adaptor input Digital display: 2 times/sec (1 time with C measurement) Bar graph: 20 times/sec LCD display 3999/40-segment bar graph Automatic switching. “-” displayed with negative polarity. The highest digit/“4” is displayed and blink HOLD (Data Hold), STORE/RECALL (Data storage/recall),MAX/MIN (Maximum/Minimum), REL (Relative value = difference from the reference value). Auto power-OFF is activated in approx. 30 minutes later. This function can be defeated. 23℃, ±5℃, 70% RH or less 5 to 40℃, 70% RH or less − 10 to 55℃, 80% RH or less (without battery) Add 0.15×(Accuracy at 23±5℃)/℃ at 0 to 18 ℃ and 28℃ to 40 ℃ 1.5V DC (SUM-3/IEC R6/LR6 manganese battery or alkaline battery × 2) Approx. 500 hours (DC V measurement using manganese batteries) Approx. 1,000 hours (DC V measurement using alkaline batteries) Approx. 77 (W)× 34 (H)× 162 (D) mm Approx. 290 g (including battery) Instruction manual (1), test lead set (1 set), batteries (IEC R6) (2) EN55011 (1991) CLASS B IEC801-2 (1991) 8kVAD IEC801-3 (1984) 3V/m IEC801-4 (1988) 1kV, 5/50 µs, 5kHz ≦3.3V DL-94 SPECIFICATIONS Continuity test DC Voltage (Auto/manual ranging except for 500 mV range) Range Resolution 0.1Ω Threshold level Built-in buzzer beeps at Measuring Open-circuit Range Resolution Current Voltage 500mV 100µV Approx. 130µA Approx. 0.4V below approx. 40Ω Maximum voltage: 500V rms Static Capacity (Automatic ranging) Range Resolution Accuracy Maximum voltage ±(1.0% of rdg + 5dgt) 500Vrms 5V 1mV 50V 10mV 500V 100mV 1000V 1V Accuracy Input Impedance Approx. 1000MΩ Approx. 11MΩ ±(0.1% of rdg + 2dgt) Approx. 10MΩ Maximum voltage: ±1200V DC, 850V AC rms (5V to 100V ranges) 4nF 1pF 40nF 10pF Range Resolution 400nF 100pF 500mV 100µV 50Hz- 60Hz : ±(1.0% of rdg + 5dgt) AC Voltage (Auto/manual ranging except for 500 mV range) Accuracy 4µF 1nF ±(1.2% of rdg + 5dgt) 5V 1mV 45Hz- 5kHz : ±(1.5% of rdg + 5dgt) 40µF 10nF ±(3.0% of rdg + 5dgt) 50V 10mV 5kHz-20kHz : ±(3.0% of rdg + 5dgt) 500V 100mV 50kHz- 60Hz : ±(1.0% of rdg + 5dgt) 750V 1V 45kHz-1kHz : ±(2.0% of rdg + 5dgt) When a film capacitor or an object with no more leakage than it is measured. ADP (For DC voltage adapter such as a clamp type current probe) Range DC400mV Resolution Accuracy Input Impedance 0.1mV ±(0.5% of rdg + 3dgt) Approx. 100MΩ Type : True r.m.s. Maximum voltage : ±1200V DC or 850V AC rms (5V to 100V ranges) ±500V DC or 350V AC rms (500mV range) Input Impedance : Approx. 1000MΩ//100pF max. (500mV range) Approx. 10MΩ//100pF max. (5V to 100V range) Maximum voltage: 500V rms Display between 0 and ±3999 with respect to input between 0 and ±399.9 mV. DC Current (Manual ranging) Range Resolution 5000µA 1µA 500mA 0.1mA 10A 10mA Accuracy ±(0.5% of rdg + 2dgt) Input protection 1A/600V 1.1V quick-blow fuse ±(1.5% of rdg+3dgt) 15A/600V quick-blow fuse 186 Voltage drop between terminals 0.4V DIGITAL MULTIMETERS DL-90 SERIES AC Current (Manual ranging) Range Resolution 5000µA 1µA 500mA 0.1mA 10A 10mA General Specifications Accuracy Input protection 45Hz-2kHz 1A/600V Measurement Functions Voltage drop between terminals 1.1V Sampling Rate Display Maximum display Polarity display ±(1.5% of rdg + 5dgt) quick-blow fuse 10A/250V 0.4V quick-blow fuse Over-range display Computations Average value detection, rms calibration Resistance (Automatic ranging) Open-circuit Range Resolution 500Ω 0.1Ω ±(0.5% of rdg + 3dgt) 3.3V ±(0.6% of rdg + 2dgt) 1.28V 5kΩ 1Ω 50kΩ 10Ω 500kΩ 100Ω Accuracy Maximum Voltage Voltage Power-Save Function 500V DC or 500Vrms 5MΩ 1kΩ ±(0.8% of rdg + 2dgt) 50MΩ 10kΩ ±(3.0% of rdg + 5dgt) Temperature/Humidity for characteristics in spec. Operating Temperature /Humidity Ranges Storage Temperature /Humidity Ranges Temperature Coefficient Frequency (Automatic ranging, minimum input frequency: 10Hz) Maximum Resolution Accuracy Input sensitivity 100Hz 0.01Hz ±(0.02% of rdg+2dgt) 300mVrms to 5Vrms 1000Hz 0.1Hz 10kHz 1Hz less than 100kHz 10Hz 10 6VHz 1MHz 100Hz 10MHz 1kHz Voltage Power source 500Vrms Battery Life but Dimensions Weight Accessories 500mVrms to 5Vrms Diode check/Continuity test Complying Standards Accuracy Measuring Current ±(1.0% of rdg+3dgt) 1mV Open-circuit Voltage Approx. 1.65mA ≦3.3V Built-in buzzer beeps at below approx. 100mV Maximum voltage: 500V DC or 500V AC rms TTL Logic Range Threshold level ▲ Display value of 2.00 V Maximum voltage 500V DC or ▼ Display value of 0.80 V 500V AC rms Static Capacity (Auto/manual ranging) Range Resolution Accuracy Maximum voltage 5nF 1pF 50nF 10pF or 500nF 100pF 500V AC rms 5000nF 1nF 50µF 10nF 500µF 100nF 5000µF ±(2.0% of rdg + 4dgt) 500V DC 1µF ±(3.0% of rdg +5dgt)/At no more than 50mF 10µF 2mF (No value specified for above 2mF.) When a film capacitor or an object with no more leakage than it is measured. Add 0.15 × (Accuracy at 23±5℃)/℃(5nF to 500nF). Add 0.3 × (Accuracy at 23±5℃)/℃(5000nF to 50mF). dBm (Auto ranging) Range Resolution Accuracy Reference impedance 50dBm 0.01dBm ±0.3dBm 20 selections >50dBm 0.1dBm 4Ω to 1200Ω Reference impedance: 4Ω, 8Ω, 16Ω, 32Ω, 50Ω, 75Ω, 93Ω, 110Ω, 125Ω, 135Ω, 150Ω, 200Ω, 250Ω, 300Ω, 500Ω, 600Ω, 800Ω, 900Ω, 1000Ω, 1200Ω 187 − 20 to 60℃, 80% RH or less (without battery) Add 0.15×(Accuracy at 23±5℃)/℃ at 0 to 18 ℃ and 28℃ to 40 ℃ 9V DC (JIS 006P, IEC 6F22 manganese battery or alkaline battery × 1) Approx. 50 hours (DC V measurement using manganese batteries) Approx. 90 hours (DC V measurement using alkaline batteries) Approx. 90 (W)× 37 (H)× 191 (D) mm Approx. 440 g (including battery) Instruction manual (1), test lead set (1 set), 9 V battery (JIS 006P/IEC 6F22) (1) EN55011 (1991) CLASS B IEC801-2 (1991) 8kVAD IEC801-3 (1984) 3V/m IEC801-4 (1988) 1kV, 5/50 µs, 5kHz DIGITAL MULTIMETERS Range Resolution 0 to 50℃, 70% RH or less DL-90 SER ES Range DC voltage, AC voltage, DC current, AC current, resistance, frequency, static capacity, logic level, diode check, continuity check Digital display: 3.3 times/sec LCD display 5000/50-segment bar graph Automatic switching. “-” displayed with negative polarity. “OL” is displayed. HOLD (Data Hold), MAX (Maximum), AVG (Average), MIN (Minimum), dBm (dBm display), ∆ (Difference from reference value), ∆/r (Deviation from reference value, %) Enters sleep mode in appr oximately 15 minutes, then auto power-OFF is activated in approx. 15 more minutes later. This function can be defeated. 23℃, ±5℃, 70% RH or less DIGITAL MULTIMETERS DC + AC Current DL-97 SPECIFICATIONS DC Voltage Range Resolution Accuracy Input protection 0.1µA/10nA 45Hz to 2kHz 1A/600V Range Resolution Accuracy Input Impedance 400µA 40mV 10µV/1µV ±(0.08% of rdg + 5dgt) Approx. 1000MΩ 4mA 400mV 0.1mV/10µV 4V 1mV/0.1mV 40V 10mV/1mV 400V 0.1V/10mV 1000V 1V/0.1V 400mA 0.1mA/10µA ±(0.06% of rdg + 3dgt) 4A 1mA/0.1mA 15A/600V 10A 10mA/1mA quick-blow fuse Type : True r.m.s. Range Resolution 40mV 10µV/1µV 50Hz- 60Hz : ±(0.7% of rdg + 5dgt) 400mV 0.1mV/10µV 45Hz- 5kHz : ±(1.5% of rdg + 5dgt) 4V 1mV/0.1mV 5kHz- 20kHz : ±(2.0% of rdg + 5dgt) 40V 10mV/1mV 400V 0.1V/10mV 750V 1V/0.1V Accuracy Crest factor: >3:1 Range Resolution Accuracy Reference impedance −80.79dBm to 0.01dBm ±0.3dBm 20 selections 81.48dBm 4Ω to 1200Ω Reference impedance: 4Ω, 8Ω, 16Ω, 32Ω, 50Ω, 75Ω, 93Ω, 110Ω, 125Ω, 135Ω, 150Ω, 200Ω, 250Ω, 300Ω, 500Ω, 600Ω, 800Ω, 900Ω, 1000Ω, 1200Ω 1 ms Peak Hold (voltage) Range Resolution Accuracy 10µV/1µV ±(2.0% of rdg + 43dgt) 400mV 0.1mV/10µV 1000MΩ 350V AC rms 4V 1mV/0.1mV Approx. ±1200V DC 40V 10mV/1mV 10MΩ 850V AC rms 400V 0.1V/10mV 1000V 1V/0.1V Range Resolution 40mV 10µV/1µV 50Hz- 60Hz : ±(0.8% of rdg + 10dgt) 400mV 0.1mV/10µV 45Hz- 5kHz : ±(1.6% of rdg + 10dgt) 400µA 4V 1mV/0.1mV 5kHz- 20kHz : ±(2.1% of rdg + 10dgt) 4mA Accuracy Range Resolution Accuracy Input protection 0.1µA/10nA ±(2.0% of rdg +43dgt) 1µA/0.1µA 40V 10mV/1mV 40mA 10µA/1µA 400V 0.1V/10mV 400mA 0.1mA/10µA 750V 1V/0.1V 1A/600V 4A 1mA/0.1mA 15A/600V 45kHz-5kHz : ±(3.0% of rdg + 10dgt) 10A 10mA/1mA quick-blow fuse 0.1µA/10nA ±(0.2% of rdg + 3dgt) 1µA/0.1µA Input protection 1A/600V 1.1V 0.4V Resistance Range 400Ω DC Current Accuracy Voltage drop between terminals quick-blow fuse 50Hz- 60Hz : ±(0.8% of rdg + 10dgt) 5kHz- 20kHz : no spec Type : True r.m.s. Crest factor: >3:1 Maximum voltage : ±1200V DC or 850V AC rms (4V to 750V ranges) ±500V DC or 350V AC rms (40mV, 400mV ranges) Input Impedance : Approx. 1000MΩ//100pF max. (40mV, 400mV ranges) Approx. 10MΩ//100pF max. (4V to 750V ranges) Voltage drop between terminals Resolution Accuracy 0.1/0.01Ω ±(0.2% of rdg + 3dgt) 4kΩ 1/0.1Ω 40kΩ 10/1Ω 400kΩ 100/10Ω 4MΩ 1k/0.1kΩ 40MΩ 1.1V Open-circuit Maximum Voltage Voltage ≦3.3V 600V DC or ≦1.28V 600Vrms 10k/1kΩ ±(1.0% of rdg + 5dgt) 40nS 0.01/0.001nS ±(1.0% of rdg + 10dgt) quick-blow fuse 40mA 10µA/1µA Static Capacity 400mA 0.1mA/10µA Range Resolution 4A 1mA/0.1mA 15A/600V 10A 10mA/1mA quick-blow fuse 0.4V AC Current Range Resolution Accuracy Input protection 400µA 0.1µA/10nA 45Hz to 2kHz 1A/600V Voltage drop between terminals 1.1V 4nF 1pF 40nF 10pF 400nF 100pF 4µF 1nF 40µF 10nF 400µF 100nF 9999µF 1µA/0.1µA ±(0.1% of rdg + 5dgt) quick-blow fuse Accuracy Maximum voltage ±(2.5% of rdg + 4dgt) 600V DC ±(2.0% of rdg + 4dgt) 600V AC rms or 1µF ±(3.0% of rdg + 4dgt)/At no more than 2 mF(No value specified for above 2 mF.) 40mA 10µA/1µA When a film capacitor or an object with no more leakage than it is measured. 400mA 0.1mA/10µA 4A 1mA/0.1mA 15A/600V 10A 10mA/1mA quick-blow fuse Type : True r.m.s. Voltage ±500V DC 1 ms Peak Hold (current) DC + AC Voltage 4mA Maximum Approx. 40mV 5kHz- 20kHz : no spec Type : True r.m.s. Crest factor: >3:1 Maximum voltage : ±1200V DC or 850V AC rms (4V to 750V ranges) ±500V DC or 350V AC rms (40mV, 400mV ranges) Input Impedance : Approx. 1000MΩ//100pF max. (40mV, 400mV ranges) Approx. 10MΩ//100pF max. (4V to 750V ranges) 4mA Input impedance 50Hz- 60Hz : ±(0.7% of rdg + 5dgt) 45kHz-5kHz : ±(3.0% of rdg + 5dgt) 400µA 0.4V dBm (Auto ranging) AC Voltage Resolution 1.1V 1µA/0.1µA ±(1.2% of rdg + 10dgt) quick-blow fuse 40mA 10µA/1µA Approx. 10MΩ Maximum voltage : ±1200V DC, 850V AC rms (4V to 750V ranges) ±500V DC, 350V AC rms (40mV, 400mV ranges) Range Voltage drop between terminals 0.4V Crest factor: >3:1 188 DIGITAL MULTIMETERS DL-90 SERIES Diode check/Continuity test Temperature Measurement (Main unit only) Accuracy/ Range Resolution Measuring Current Threshold level 1mV/ ±(1.0% of rdg+2dgt)/ 0.1mV Approx. 100mV or less Open-circuit Range Voltage − 40℃ to 1372℃ Accuracy 100Hz 0.01/0.001Hz ±(0.02% of rdg+2dgt) 1kHz 0.1/0.01Hz 10kHz 1/0.1Hz 100kHz 10/1Hz 200Hz 100/10Hz Minimum input Maximum Frequency Voltage 10Hz 1200V DC 500V DC or 500V AC rms Accuracy ±0.4% 100Hz, 150Hz, 200Hz, 300Hz, 600Hz, 10 6VHz 1200Hz, 1600Hz, 2400Hz, 4800Hz, Duty cycle 1% to 99% ±0.4% Amplitude 0V to 3V fixed ±0.2V Output impedance 3.5kΩ max. Input level (sine wave) 40Hz-20kHz Timer Output 10Hz-200kHz Accuracy No minimum sensitivity specification 40mV 10mV to 400mV 400mV 30mV to 4V 40mV to 4V 4V 0.3V to 40V 0.4V to 40V 40V 3V to 400V 4V to 400V Maximum time 99.999 sec. but up to 400 mV. 30V to 1000V 40V (<100kHz) to 1000V 300V to 1000V 400V (<100kHz) to 1000V Amplitude 0V to 3V fixed Output signal 1. High to Low 2. Low Pulse 100Hz 0.01/0.001Hz ±(0.002% of rdg+1dgt) 100mV rms 1kHz 0.1/0.01Hz 10kHz 1/0.1Hz 100kHz 10/1Hz 200Hz 100/10Hz 0.1/0.01Hz 10kHz 1/0.1Hz 100kHz 10/1Hz 1MHz 100/10Hz 10MHz 100/10Hz Approx. 3msec. Sampling Rate Display Back light Maximum display Polarity display Minimum input Frequency 1Hz Over-range display Computations Output Functions Power-Save Function Accuracy Sensitivity 100Hz 0.01/0.001Hz ±(0.002% of rdg+1dgt) 100mV rms 1kHz 0V to 3V 4. High Pulse Measurement Functions Frequency (Division factor 10) Resolution 3. Low to High Minimum input Frequency 50Hz Temperature/Humidity for characteristics in spec. Operating Temperature /Humidity Ranges Storage Temperature /Humidity Ranges Temperature Coefficient 500mV rms •Maximum voltage: 1200V DC/850V rms; 10 6V・Hz In 5 Vp-p square wave. •Duty cycle range: 0.1% to 99.9% •Duty cycle accuracy: ±(0.3% per kHz +0.3%) of full scale •Pulse duration measuring range: 0.1 ms to 1999 ms •Pulse duration measuring accuracy: ±(0.2% of rdg+3dgt) The pulse duration measurement range is dependent on the input signal frequency. Power source Battery Life Dimensions Weight Accessories Complying Standards 189 DC voltage, AC voltage, DC + AC voltage, DC current, AC current, DC+AC current, resistance, frequency, static capacity, diode check, continuity check, temperature Digital display: 3 times/sec (4000 full scale) 1 times/sec (40000 full scale) LCD display ON/OFF switchable 5000/20 × 4-segment bar graph Automatic switching. “-” displayed with negative polarity. “OL” is displayed. HOLD (Data Hold), MAX (Maximum), AVG (Average), MIN (Minimum), dBm (dBm display), ∆ (Difference from reference value), ∆/r (Deviation from reference value) Square wave output, timer output Enters sleep mode in appr oximately 15 minutes, then auto power-OFF is activated in approx. 15 more minutes later. This function can be defeated. 23℃, ±5℃, 80% RH or less 0 to 50℃, 80% RH or less − 20 to 60℃, 80% RH or less (without battery) Add 0.15×(Accuracy at 23±5℃)/℃ at 0 to 18 ℃ and 28℃ to 40 ℃ 9V DC (JIS 006P, IEC 6F22 manganese battery or alkaline battery × 1) Approx. 50 hours (DC V measurement using manganese batteries) Approx. 90 hours (DC V measurement using alkaline batteries) Approx. 90 (W)× 37 (H)× 191 (D) mm Approx.440 g (including battery) Instruction manual (1), test lead set (1 set), 9 V battery (JIS 006P/IEC 6F22) (1), holster (1) EN55011 (1991) CLASS B IEC801-2 (1991) 8kVAD IEC801-3 (1984) 3V/m IEC801-4 (1988) 1kV, 5/50 µs, 5kHz DIGITAL MULTIMETERS Sensitivity 3V to 0V Approx. 3msec. General Specifications Frequency (Division factor 1) Accuracy ±0.2% Output impedance 3.5kΩ max. In 4 V DC range, with 5 Vp-p square wave. •Duty cycle range: 5% to 95% •Duty cycle accuracy: ±(0.3% per kHz +0.3%) of full scale •Pulse duration measuring range: 0.1 ms to 1999 ms •Pulse duration measuring accuracy: ±(0.2% of rdg+3dgt) The pulse duration measurement range is dependent on the input signal frequency. Resolution ±0.4% DL-90 SER ES 400V 1000V Range ±(0.3% of rdg + 6F) Frequency 0.5Hz, 1Hz, 2Hz, 10Hz, 50Hz, 60Hz, 75Hz, 850V rms Input Range 1F Square-wave Output Input Sensitivity range Maximum Input Voltage •Temperature Probe (Optional PC-597) Measuring range : − 40℃ to 204℃ Measuring accuracy : Larger value of ±0.75% and ±2.2℃ (0℃ to 204℃) Larger value of ±2% and ±2.2℃ (− 40℃ to 0℃) Frequency (at voltage measurement) Resolution Accuracy 1℃ ±(0.3% of rdg + 3℃) − 40F to 2502F Approx. 1.65mA ≦3.3V Maximum voltage: 600V DC or 600V AC rms Range Resolution
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement