null  null
Version
05.00
¸ZVA Vector Network Analyzer
January
2008
Data sheet
Titel+Rueck_ZVA_dat-sw_en.indd 1
24.01.2008 09:42:37
CONTENTS
Measurement range ........................................................................................................................................................ 3
Measurement speed........................................................................................................................................................ 6
Measurement accuracy .................................................................................................................................................. 7
Effective system data ................................................................................................................................................... 14
Test port output ............................................................................................................................................................ 15
Test port input ............................................................................................................................................................... 18
Additional front panel connectors............................................................................................................................... 20
Optional front panel connectors.................................................................................................................................. 20
Display ........................................................................................................................................................................... 20
Rear panel connectors ................................................................................................................................................. 20
Options .......................................................................................................................................................................... 22
General data .................................................................................................................................................................. 25
Ordering information .................................................................................................................................................... 26
2
®
R&S ZVA Vector Network Analyzer
Version 05.00, January 2008
Specifications are valid under the following conditions:
90 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and all internal
adjustments performed. Data designated „overrange“ and data without tolerance limits is not binding. Unless otherwise stated,
specifications apply to test ports and a nominal source power of –10 dBm.
Measurement range
Impedance
50 Ω
®
Test port connector
R&S ZVA8
®
R&S ZVA24
®
R&S ZVA40
®
R&S ZVA50
®
R&S ZVA8
®
R&S ZVA24
®
R&S ZVA40
®
R&S ZVA50
®
R&S ZVA8
®
R&S ZVA24
®
R&S ZVA40
®
R&S ZVA50
without optional oven quartz
with optional oven quartz
Number of test ports
Frequency range
Static frequency accuracy
Frequency resolution
Number of measurement points
Measurement bandwidths
®
Dynamic range of the R&S ZVA8
(without optional step attenuators
and without optional direct
generator/receiver access)
®
Dynamic range of the R&S ZVA24
(without optional step attenuators
and without optional direct
generator/receiver access)
®
Dynamic range of the R&S ZVA40
(without optional step attenuators
and without optional direct
generator/receiver access)
®
Dynamic range of the R&S ZVA50
(without optional step attenuators
and without optional direct
generator/receiver access)
Version 05.00, January 2008
user-selectable
1/2/5 steps
from PORT 1 to PORT 2 and
from PORT 3 to PORT 4
300 kHz to 50 MHz
50 MHz to 100 MHz
100 MHz to 4 GHz
4 GHz to 7 GHz
7 GHz to 8 GHz
from PORT 1 to PORT 2 and
from PORT 3 to PORT 4
10 MHz to 100 MHz
100 MHz to 700 MHz
700 MHz to 2 GHz
2 GHz to 13 GHz
13 GHz to 24 GHz
from PORT 1 to PORT 2 and
from PORT 3 to PORT 4
10 MHz to 50 MHz
50 MHz to 500 MHz
500 MHz to 2 GHz
2 GHz to 20 GHz
20 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
from PORT 1 to PORT 2 and
from PORT 3 to PORT 4
10 MHz to 50 MHz
50 MHz to 500 MHz
500 MHz to 2 GHz
2 GHz to 20 GHz
20 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
40 GHz to 50 GHz
type N, female
3.5 mm, male
2.92 mm, male
2.4 mm, male
2 or 4
2 or 4
2 or 4
2 or 4
300 kHz to 8 GHz
10 MHz to 24 GHz
10 MHz to 40 GHz
10 MHz to 50 GHz
–6
8×10
–7
1×10
1 Hz
2 to 60001
1 Hz to 1 MHz
>100 dB, typ. 110 dB
>120 dB, typ. 130 dB
>130 dB, typ. 140 dB
>125 dB, typ. 135 dB
>120 dB, typ. 130 dB
>90 dB, typ. 105 dB
>105 dB, typ. 120 dB
>125 dB, typ. 130 dB
>130 dB, typ. 135 dB
>125 dB, typ. 130 dB
>90 dB, typ. 100 dB
>105 dB, typ. 115 dB
>125 dB, typ. 135 dB
>130 dB, typ. 140 dB
>125 dB, typ. 135 dB
>115 dB, typ. 125 dB
>110 dB, typ. 115 dB
>90 dB, typ. 100 dB
>105 dB, typ. 115 dB
>125 dB, typ. 135 dB
>130 dB, typ. 140 dB
>125 dB, typ. 135 dB
>120 dB, typ. 130 dB
>115 dB, typ. 125 dB
>110 dB, typ. 120 dB
®
R&S ZVA Vector Network Analyzer
3
from PORT 1 to MEAS 2 IN
300 kHz to 10 MHz
typ. >125 dB
10 MHz to 100 MHz
typ. >135 dB
100 MHz to 8 GHz
typ. >145 dB
Dynamic range at optional measurement
from PORT 1 to MEAS 2 IN
input (direct generator/receiver access
10 MHz to 100 MHz
typ. >135 dB
®
option) of the R&S ZVA24
100 MHz to 13 GHz
typ. >145 dB
13 GHz to 20 GHz
typ. >140 dB
20 GHz to 24 GHz
typ. >130 dB
Dynamic range at optional measurement
from PORT 1 to MEAS 2 IN
input (direct generator/receiver access
10 MHz to 100 MHz
typ. >140 dB
®
option) of the R&S ZVA40
100 MHz to 20 GHz
typ. >150 dB
20 GHz to 24 GHz
typ. >140 dB
24 GHz to 32 GHz
typ. >130 dB
32 GHz to 40 GHz
typ. >120 dB
Dynamic range at optional measurement
from PORT 1 to MEAS 2 IN
input (direct generator/receiver access
10 MHz to 100 MHz
typ. >140 dB
®
option) of the R&S ZVA50
100 MHz to 20 GHz
typ. >150 dB
20 GHz to 24 GHz
typ. >145 dB
24 GHz to 32 GHz
typ. >140 dB
32 GHz to 40 GHz
typ. >135 dB
40 GHz to 50 GHz
typ. >130 dB
The dynamic range is defined as the difference between the actually available maximum source power and the rms value of the data
trace of the transmission magnitude, which is produced by noise and crosstalk with the test ports short-circuited. The specification is
valid without system error correction and at 10 Hz measurement bandwidth. The dynamic range can be increased by using a
measurement bandwidth of 1 Hz.
Dynamic range at optional measurement
input (direct generator/receiver access
®
option) of the R&S ZVA8
®
Diagram: Dynamic range in dB versus frequency in GHz of the R&S ZVA8
4
®
R&S ZVA Vector Network Analyzer
Version 05.00, January 2008
®
Diagram: Dynamic range in dB versus frequency in GHz of the R&S ZVA24
®
Diagram: Dynamic range in dB versus frequency in GHz of the R&S ZVA40
®
Diagram: Dynamic range in dB versus frequency in GHz of the R&S ZVA50
Version 05.00, January 2008
®
R&S ZVA Vector Network Analyzer
5
Measurement speed
Measurement time
Measurement time per point
Data transfer time
Time for measurement and data transfer
Switching time between channels
Switching time between two preloaded
instrument settings
for 201 measurements points, with span
100 MHz, 500 kHz measurement
bandwidth, ALC and display switched off
with center frequency 1.1 GHz
with center frequency 5.1 GHz
CW mode,
1 MHz measurement bandwidth
for 201 measurements points
via IEC/IEEE bus
via VX11 over 100 Mbit/s LAN
via RSIB over 100 Mbit/s LAN
for 201 measurements points, with start
frequency 1 GHz, stop frequency 1.1 GHz,
500 kHz measurement bandwidth, and
display switched off
(No additional time for data transfer is
needed, as this occurs simultaneously
during the measurement.)
with no more than 2001 points
with no more than 2001 points
<6 ms
<4.5 ms
<3.5 µs
<2.9 ms
<1.3 ms
<0.7 ms
<6 ms
<1 ms
<10 ms
®
Sweep times of the R&S ZVA
Sweep times depend on the number of measurement points, the measurement bandwidth, and the start and stop frequencies.
They include times for retrace and internal band switching and are valid with ALC and display switched off.
Number of measurement points 51
101
201
401
801
1601
®
R&S ZVA with start frequency 5 GHz, stop frequency 5.2 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
2.6 ms
4.0 ms
6.8ms
12 ms
23 ms
42 ms
With TOSM calibration
3.8 ms
6.5 ms
11.6 ms
22 ms
41 ms
124 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
2.1 ms
3.0 ms
4.7 ms
8.0 ms
15 ms
26 ms
With TOSM calibration
2.8 ms
4.5 ms
7.5 ms
14 ms
26 ms
94 ms
®
R&S ZVA with start frequency 6 GHz, stop frequency 8 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
3.6 ms
6.4 ms
With TOSM calibration
4.8 ms
8.9 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
3.1 ms
5.4 ms
With TOSM calibration
3.8 ms
6.8 ms
11.5 ms
16.3 ms
19 ms
29 ms
31 ms
49 ms
50 ms
132 ms
9.4 ms
12.2 ms
14.7 ms
20.5 ms
23 ms
33 ms
35 ms
103 ms
32 ms
41 ms
55 ms
74 ms
92 ms
173 ms
28 ms
33 ms
47 ms
57 ms
75 ms
143 ms
®
R&S ZVA8 with start frequency 10 MHz and stop frequency 8 GHz
®
R&S ZVA24 with start frequency 10 MHz and stop frequency 24 GHz
®
R&S ZVA40 with start frequency 10 MHz and stop frequency 40 GHz
®
R&S ZVA50 with start frequency 10 MHz and stop frequency 50 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
8.6 ms
13 ms
19.4 ms
With TOSM calibration
9.9 ms
15.5 ms
25 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
8.2 ms
12 ms
17.4 ms
With TOSM calibration
8.8 ms
13.4 ms
20.2 ms
®
Table: Sweep times of the R&S ZVA
6
®
R&S ZVA Vector Network Analyzer
Version 05.00, January 2008
Measurement accuracy
This data is valid between 18 °C and 28 °C, provided the temperature has not varied by more than 1 K after calibration. Validity of the
data is conditional on the use of a suitable calibration kit. This calibration kit is used to achieve the effective system data specified
below. Frequency points, measurement bandwidth, and sweep time have to be identical for measurement and calibration (no
interpolation allowed).
Accuracy of transmission measurements
®
R&S ZVA8
300 kHz to 1 MHz
for +15 dB to –45 dB
1 MHz to 50 MHz
for +15 dB to –30 dB
for –30 dB to –45 dB
50 MHz to 8 GHz
for +15 dB to +5 dB
for +5 dB to –55 dB
for –55 dB to –70 dB
for –70 dB to –85 dB
®
R&S ZVA24
10 MHz to 50 MHz
for +15 dB to –30 dB
50 MHz to 400 MHz
for +15 dB to –30 dB
for –30 dB to –45 dB
400 MHz to 700 MHz
for +15 dB to –50 dB
for –50 dB to –65 dB
700 MHz to 24 GHz
for +15 dB to +5 dB
for +5 dB to –55 dB
for –55 dB to –70 dB
for –70 dB to –85 dB
®
R&S ZVA40
10 MHz to 50 MHz
for +15 dB to –30 dB
50 MHz to 250 MHz
for +15 dB to –30 dB
for –30 dB to –45 dB
250 MHz to 700 MHz
for +15 dB to +5 dB
for +5 dB to –65 dB
for –65 dB to –80 dB
700 MHz to 2 GHz
for +15 dB to +5 dB
for +5 dB to –50 dB
for –50 dB to –65 dB
for –65 dB to –80 dB
2 GHz to 24 GHz
for +15 dB to +5 dB
for +5 dB to –55 dB
for –55 dB to –70 dB
for –70 dB to –85 dB
24 GHz to 32 GHz
for +15 dB to +5 dB
for +5 dB to –45 dB
for –45 dB to –60 dB
for –60 dB to –75 dB
32 GHz to 40 GHz
for +15 dB to +5 dB
for +5 dB to –40 dB
for –40 dB to –55 dB
for –55 dB to –70 dB
Version 05.00, January 2008
<1 dB or <6°
<0.2 dB or <2°
<1 dB or <6°
<0.2 dB or <2°
<0.1 dB or <1°
<0.2 dB or <2°
<1 dB or <6°
<1 dB or <6°
<0.2 dB or <2°
<1 dB or <6°
<0.2 dB or <2°
<1 dB or <6°
<0.2 dB or <2°
<0.1 dB or <1°
<0.2 dB or <2°
<1 dB or <6°
<1 dB or <6°
<0.2 dB or <2°
<1 dB or <6°
<0.3 dB or <3°
<0.2 dB or <2°
<1 dB or <6°
<0.3 dB or <3°
<0.1 dB or <1°
<0.2 dB or <2°
<1 dB or <6°
<0.3 dB or <3°
<0.1 dB or <1°
<0.2 dB or <2°
<1 dB or <6°
<0.3 dB or <3°
<0.2 dB or <2°
<0.3 dB or <3°
<1 dB or <6°
<0.4 dB or <4°
<0.2 dB or <2°
<0.4 dB or <4°
<1 dB or <6°
®
R&S ZVA Vector Network Analyzer
7
®
R&S ZVA50
10 MHz to 50 MHz
50 MHz to 250 MHz
for +15 dB to –30 dB
<1 dB or <6°
for +15 dB to –30 dB
<0.2 dB or <2°
for –30 dB to –45 dB
<1 dB or <6°
250 MHz to 700 MHz
for +15 dB to +5 dB
<0.3 dB or <3°
for +5 dB to –65 dB
<0.2 dB or <2°
for –65 dB to –80 dB
<1 dB or <6°
700 MHz to 2 GHz
for +15 dB to +5 dB
<0.3 dB or <3°
for +5 dB to –50 dB
<0.1 dB or <1°
for –50 dB to –65 dB
<0.2 dB or <2°
for –65 dB to –80 dB
<1 dB or <6°
2 GHz to 24 GHz
for +15 dB to +5 dB
<0.3 dB or <3°
for +5 dB to –55 dB
<0.1 dB or <1°
for –55 dB to –70 dB
<0.2 dB or <2°
for –70 dB to –85 dB
<1 dB or <6°
24 GHz to 32 GHz
for +15 dB to +5 dB
<0.3 dB or <3°
for +5 dB to –45 dB
<0.2 dB or <2°
for –45 dB to –60 dB
<0.3 dB or <3°
for –60 dB to –75 dB
<1 dB or <6°
32 GHz to 40 GHz
for +15 dB to +5 dB
<0.4 dB or <4°
for +5 dB to –40 dB
<0.2 dB or <2°
for –40 dB to –55 dB
<0.4 dB or <4°
for –55 dB to –70 dB
<1 dB or <6°
40 GHz to 50 GHz
for +15 dB to +5 dB
<0.4 dB or <4°
for +5 dB to –35 dB
<0.2 dB or <2°
for –35 dB to –50 dB
<0.4 dB or <4°
for –50 dB to –65 dB
<1 dB or <6°
Specifications are based on a matched DUT, a measurement bandwidth of 10 Hz, and a nominal source power of –10 dBm.
Trace stability
Trace noise of S11 (rms)
®
R&S ZVA8
®
R&S ZVA24
®
R&S ZVA40
®
R&S ZVA50
Temperature dependence
8
®
R&S ZVA Vector Network Analyzer
at 0 dBm source power, 0 dB reflection, and 1 kHz measurement bandwidth
300 kHz to 8 GHz
<0.004 dB, typ. 0.001 dB
700 MHz to 24 GHz
<0.004 dB, typ. 0.001 dB
700 MHz to 24 GHz
<0.004 dB, typ. 0.001 dB
24 GHz to 40 GHz
<0.015 dB, typ. 0.004 dB
700 MHz to 24 GHz
<0.004 dB, typ. 0.001 dB
24 GHz to 50 GHz
<0.015 dB, typ. 0.004 dB
at 0 dB transmission or reflection
up to 24 GHz
<0.05 dB/K or <0.4°/K
24 GHz to 50 GHz
<0.1 dB/K or <1°/K
Version 05.00, January 2008
Phase
Magnitude
1
0.1
0.01
0
100
Uncertainty / deg
Uncertainty / dB
10
-20
-40
-60
-80
10
1
0.1
0
-100
-20
-40
-60
-80
-100
Transm ission coefficient / dB
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA8
in the frequency range 300 kHz to 4 GHz
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
Transmission coefficient / dB
-100
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA8
in the frequency range 4 GHz to 8 GHz
Version 05.00, January 2008
®
R&S ZVA Vector Network Analyzer
9
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA24
in the frequency range 10 MHz to 700 MHz
Phase
Magnitude
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
Transmission coefficient / dB
-100
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA24
in the frequency range 700 MHz to 24 GHz
10
®
R&S ZVA Vector Network Analyzer
Version 05.00, January 2008
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA40
in the frequency range 10 MHz to 700 MHz
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA40
in the frequency range 700 MHz to 24 GHz
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
Transmission coefficient / dB
-100
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA40
in the frequency range 24 GHz to 40 GHz
Version 05.00, January 2008
®
R&S ZVA Vector Network Analyzer
11
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA50
in the frequency range 10 MHz to 700 MHz
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA50
in the frequency range 700 MHz to 24 GHz
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
Transmission coefficient / dB
-100
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
®
Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA50
in the frequency range 24 GHz to 50 GHz
12
®
R&S ZVA Vector Network Analyzer
Version 05.00, January 2008
Accuracy of reflection measurements
®
R&S ZVA8
300 kHz to 1 MHz
1 MHz to 8 GHz
for +10 dB to –25 dB
for –25 dB to –35 dB
for +10 dB to +3 dB
for +3 dB to –15 dB
for –15 dB to –25 dB
for –25 dB to –35 dB
<1 dB or <6°
<3 dB or <20°
<0.6 dB or <4°
<0.4 dB or <3°
<1 dB or <6°
<3 dB or <20°
for +3 dB to –15 dB
for –15 dB to –25 dB
for +10 dB to +3 dB
for +3 dB to –15 dB
for –15 dB to –25 dB
for –25 dB to –35 dB
<1 dB or <6°
<3 dB or <20°
<0.6 dB or <4°
<0.4 dB or <3°
<1 dB or <6°
<3 dB or <20°
for +3 dB to –15 dB
for –15 dB to –25 dB
for +10 dB to +3 dB
for +3 dB to –15 dB
for –15 dB to –25 dB
for –25 dB to –35 dB
<1 dB or <6°
<3 dB or <20°
<0.6 dB or <4°
<0.4 dB or <3°
<1 dB or <6°
<3 dB or <20°
®
R&S ZVA24
10 MHz to 50 MHz
50 MHz to 24 GHz
®
R&S ZVA40
10 MHz to 50 MHz
50 MHz to 40 GHz
®
R&S ZVA50
10 MHz to 50 MHz
for +3 dB to –15 dB
<1 dB or <6°
for –15 dB to –25 dB
<3 dB or <20°
50 MHz to 50 GHz
for +10 dB to +3 dB
<0.6 dB or <4°
for +3 dB to –15 dB
<0.4 dB or <3°
for –15 dB to –25 dB
<1 dB or <6°
for –25 dB to –35 dB
<3 dB or <20°
Specifications are based on an isolating DUT, a measurement bandwidth of 10 Hz, and a nominal source power of –10 dBm.
Phase
0.05
Uncertainty / deg
Uncertainty (linear)
Magnitude
0.04
0.03
0.02
0.01
0.00
0
0.2
0.4
0.6
0.8
Reflection coefficient (linear)
1
10
8
6
4
2
0
0
0.2
0.4
0.6
0.8
1
Reflection coefficient (linear)
Diagram: Typical accuracy of reflection magnitude and reflection phase measurements
®
of the R&S ZVA8 in the frequency range 1 MHz to 8 GHz,
®
of the R&S ZVA24 in the frequency range 50 MHz to 24 GHz,
®
of the R&S ZVA40 in the frequency range 50 MHz to 40 GHz,
®
and of the R&S ZVA50 in the frequency range 50 MHz to 50 GHz
Version 05.00, January 2008
®
R&S ZVA Vector Network Analyzer
13
Effective system data
This data is valid between 18 °C and 28 °C, provided the temperature has not varied by more than 1 K after calibration. The data is
based on a measurement bandwidth of 10 Hz and system error calibration by means of a suitable calibration kit. Frequency points,
measurement bandwidth, and sweep time have to be identical for measurement and calibration (no interpolation allowed).
®
R&S ZVA8
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
300 kHz to 4 GHz
4 GHz to 8 GHz
300 kHz to 4 GHz
4 GHz to 8 GHz
1 MHz to 4 GHz
4 GHz to 8 GHz
300 kHz to 4 GHz
4 GHz to 8 GHz
1 MHz to 4 GHz
4 GHz to 8 GHz
>46 dB, typ. 50 dB
>40 dB, typ. 50 dB
>40 dB, typ. 46 dB
>36 dB, typ. 40 dB
<0.04 dB, typ. 0.01 dB
<0.1 dB, typ. 0.01 dB
>46 dB, typ. 50 dB
>40 dB, typ. 46 dB
<0.06 dB, typ. 0.01 dB
<0.1 dB, typ. 0.05 dB
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
>36 dB, typ. 40 dB
>40 dB, typ. 50 dB
>30 dB, typ. 48 dB
>30 dB, typ. 48 dB
<0.3 dB, typ. 0.05 dB
<0.3 dB, typ. 0.05 dB
>36 dB, typ. 40 dB
>40 dB, typ. 50 dB
<0.2 dB, typ. 0.1 dB
<0.1 dB, typ. 0.05 dB
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
>30 dB, typ. 40 dB
>36 dB, typ. 46 dB
>30 dB, typ. 40 dB
>30 dB, typ. 36 dB
>30 dB, typ. 40 dB
>30 dB, typ. 36 dB
<0.3 dB, typ. 0.1 dB
<0.3 dB, typ. 0.1 dB
<0.3 dB, typ. 0.2 dB
>32 dB, typ. 40 dB
>36 dB, typ. 46 dB
>32 dB, typ. 40 dB
<0.2 dB, typ. 0.1 dB
<0.1 dB, typ. 0.05 dB
<0.2 dB, typ. 0.1 dB
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
>30 dB, typ. 40 dB
>36 dB, typ. 46 dB
>30 dB, typ. 40 dB
>30 dB, typ. 36 dB
>30 dB, typ. 40 dB
>30 dB, typ. 36 dB
<0.3 dB, typ. 0.1 dB
<0.3 dB, typ. 0.1 dB
<0.3 dB, typ. 0.2 dB
>32 dB, typ. 40 dB
>36 dB, typ. 46 dB
>32 dB, typ. 40 dB
<0.2 dB, typ. 0.1 dB
<0.1 dB, typ. 0.05 dB
<0.2 dB, typ. 0.1 dB
®
R&S ZVA24
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
®
R&S ZVA40
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
®
R&S ZVA50
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
14
®
R&S ZVA Vector Network Analyzer
Version 05.00, January 2008
Test port output
Power range
(without optional step attenuators
and without optional direct
generator/receiver access)
Power accuracy
(with ALC on and
without power calibration)
Power linearity
in temperature range 18 °C to 28 °C
(with ALC on and
without power calibration)
Power resolution
Harmonics
(output power referenced to maximum
specified output power)
Version 05.00, January 2008
®
R&S ZVA8
300 kHz to 50 MHz
50 MHz to 4 GHz
4 GHz to 7 GHz
7 GHz to 8 GHz
®
R&S ZVA24
10 MHz to 13 GHz
13 GHz to 24 GHz
®
R&S ZVA40
10 MHz to 50 MHz
50 MHz to 20 GHz
20 GHz to 32 GHz
32 GHz to 40 GHz
®
R&S ZVA50
10 MHz to 50 MHz
50 MHz to 20 GHz
20 GHz to 32 GHz
32 GHz to 50 GHz
®
R&S ZVA8 at –10 dBm
in temperature range 18 °C to 28 °C
50 MHz to 8 GHz
®
R&S ZVA24 at –10 dBm
in temperature range 18 °C to 28 °C
500 MHz to 24 GHz
®
R&S ZVA40 at –10 dBm
in temperature range 18 °C to 28 °C
500 MHz to 24 GHz
24 GHz to 40 GHz
®
R&S ZVA50 at –10 dBm
in temperature range 18 °C to 28 °C
500 MHz to 24 GHz
24 GHz to 50 GHz
referenced to –10 dBm
above 50 MHz
®
R&S ZVA8 above 50 MHz
®
R&S ZVA24 above 500 MHz
®
R&S ZVA40 above 500 MHz
®
R&S ZVA50 above 500 MHz
–40 dBm to +10 dBm, typ. –45 to +14 dBm
–40 dBm to +13 dBm, typ. –45 to +15 dBm
–40 dBm to +10 dBm, typ. –45 to +13 dBm
–40 dBm to +8 dBm, typ. –45 to +12 dBm
–30 dBm to +13 dBm, typ. –40 to +18 dBm
–30 dBm to +10 dBm, typ. –40 to +16 dBm
–30 dBm to +10 dBm, typ. –40 to +15 dBm
–30 dBm to +13 dBm, typ. –40 to +18 dBm
–30 dBm to +10 dBm, typ. –40 to +15 dBm
–30 dBm to +6 dBm, typ. –40 to +12 dBm
–30 dBm to +10 dBm, typ. –40 to +15 dBm
–30 dBm to +13 dBm, typ. –40 to +18 dBm
–30 dBm to +10 dBm, typ. –40 to +15 dBm
–30 dBm to +6 dBm, typ. –40 to +12 dBm
<2 dB
<0.8 dB, typ. 0.3 dB
<3 dB
<0.8 dB, typ. 0.3 dB
<3 dB
<0.8 dB, typ. 0.3 dB
<2 dB, typ. 0.8 dB
<3 dB
<0.8 dB, typ. 0.3 dB
<2 dB, typ. 0.8 dB
<2 dB
<0.8 dB, typ. 0.3 dB
<0.8 dB, typ. 0.3 dB
<0.8 dB, typ. 0.3 dB
<0.8 dB, typ. 0.3 dB
0.01 dB
®
R&S ZVA8
300 kHz to 50 MHz at –3 dB
50 MHz to 4 GHz at –5 dB
4 GHz to 7 GHz at –2 dB
7 GHz to 8 GHz at 0 dB
®
R&S ZVA24
10 MHz to 50 MHz at –3 dB
50 MHz to 13 GHz at –3 dB
13 GHz to 24 GHz at 0 dB
®
R&S ZVA40
10 MHz to 50 MHz at –3 dB
50 MHz to 20 GHz at –3 dB
20 GHz to 40 GHz at 0 dB
®
R&S ZVA50
10 MHz to 50 MHz at –3 dB
50 MHz to 20 GHz at –3 dB
20 GHz to 50 GHz at –5 dB
typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
<–20 dBc, typ. <–30 dBc
®
R&S ZVA Vector Network Analyzer
15
®
Diagram: Maximum output power in dBm versus frequency in GHz of the R&S ZVA8
®
Diagram: Maximum output power in dBm versus frequency in GHz of the R&S ZVA24
®
Diagram: Maximum output power in dBm versus frequency in GHz of the R&S ZVA40
®
Diagram: Maximum output power in dBm versus frequency in GHz of the R&S ZVA50
16
®
R&S ZVA Vector Network Analyzer
Version 05.00, January 2008
®
Diagram: Output power accuracy in dB versus frequency in GHz of the R&S ZVA8
®
Diagram: Output power accuracy in dB versus frequency in GHz of the R&S ZVA24
®
Diagram: Output power accuracy in dB versus frequency in GHz of the R&S ZVA40
®
Diagram: Output power accuracy in dB versus frequency in GHz of the R&S ZVA50
Version 05.00, January 2008
®
R&S ZVA Vector Network Analyzer
17
Test port input
Match
Maximum nominal input level
Power measurement accuracy
18
®
R&S ZVA Vector Network Analyzer
without system error correction
®
R&S ZVA8
300 kHz to 7 GHz
7 GHz to 8 GHz
®
R&S ZVA24
10 MHz to 50 MHz
50 MHz to 2 GHz
2 GHz to 24 GHz
®
R&S ZVA40
10 MHz to 4 GHz
4 GHz to 20 GHz
20 GHz to 40 GHz
®
R&S ZVA50
10 MHz to 50 MHz
50 MHz to 10 GHz
10 GHz to 20 GHz
20 GHz to 40 GHz
40 GHz to 50 GHz
®
R&S ZVA8
300 kHz to 8 GHz
®
R&S ZVA24
10 MHz to 13 GHz
13 GHz to 24 GHz
®
R&S ZVA40
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 40 GHz
®
R&S ZVA50
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 50 GHz
at –10 dBm without power calibration
in temperature range 18 °C to 28 °C
®
R&S ZVA8
10 MHz to 8 GHz
®
R&S ZVA24
10 MHz to 13 GHz
13 GHz to 24 GHz
®
R&S ZVA40
10 MHz to 50 MHz
50 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 40 GHz
®
R&S ZVA50
10 MHz to 50 MHz
50 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 50 GHz
>16 dB
>14 dB
>10 dB
>12 dB
>8 dB
>12 dB
>8 dB
>6 dB
>8 dB
>10 dB
>8 dB
>6 dB
>5 dB
+13 dBm
+15 dBm
+10 dBm
+10 dBm
+6 dBm
+3 dBm
+10 dBm
+6 dBm
+3 dBm
<1 dB
<1 dB
<2 dB
<2 dB
<1 dB
<2 dB
<3 dB
<2 dB
<1 dB
<2 dB
<3 dB
Version 05.00, January 2008
Receiver linearity
Damage level
Damage DC voltage
Noise level
(without optional step attenuators
and without optional direct
generator/receiver access)
Version 05.00, January 2008
referenced to –10 dBm
in temperature range 18 °C to 28 °C
®
R&S ZVA8
for +20 dB to –60 dB
50 MHz to 8 GHz
®
R&S ZVA24
for +20 dB to –30 dB
50 MHz to 700 MHz
for +20 dB to +10 dB
700 MHz to 24 GHz
for +10 dB to –45 dB
700 MHz to 24 GHz
®
R&S ZVA40
for +20 dB to –30 dB
50 MHz to 250 MHz
for +10 dB to +5 dB
250 MHz to 40 GHz
for +5 dB to –45 dB
250 MHz to 40 GHz
®
R&S ZVA50
for +20 dB to –30 dB
50 MHz to 250 MHz
for +10 dB to +5 dB
250 MHz to 50 GHz
for +5 dB to –45 dB
250 MHz to 50 GHz
at 10 Hz measurement bandwidth
®
R&S ZVA8
300 kHz to 100 MHz
100 MHz to 8 GHz
®
R&S ZVA24
100 MHz to 700 MHz
700 MHz to 2 GHz
2 GHz to 13 GHz
13 GHz to 24 GHz
®
R&S ZVA40
100 MHz to 500 MHz
500 MHz to 2 GHz
2 GHz to 20 GHz
20 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
®
R&S ZVA50
100 MHz to 500 MHz
500 MHz to 2 GHz
2 GHz to 20 GHz
20 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
40 GHz to 50 GHz
<0.1 dB
<0.1 dB
<0.3 dB
<0.1 dB
<0.1 dB
<0.3 dB
<0.1 dB
<0.1 dB
<0.3 dB
<0.1 dB
+27 dBm
30 V
<–100 dBm
<–115 dBm
<–80 dBm
<–110 dBm
<–115 dBm
<–110 dBm
<–80 dBm
<–110 dBm
<–115 dBm
<–110 dBm
<–100 dBm
<–95 dBm
<–80 dBm
<–110 dBm
<–115 dBm
<–110 dBm
<–105 dBm
<–100 dBm
<–95 dBm
®
R&S ZVA Vector Network Analyzer
19
at 10 Hz measurement bandwidth
®
R&S ZVA8
100 MHz to 8 GHz
®
R&S ZVA24
100 MHz to 24 GHz
®
R&S ZVA40
100 MHz to 24 GHz
24 GHz to 40 GHz
®
R&S ZVA50
100 MHz to 24 GHz
24 GHz to 40 GHz
40 GHz to 50 GHz
The noise level is defined as the rms value of the indicated noise floor.
Noise level at optional measurement input
(direct generator/receiver access option)
typ. <–130 dBm
typ. <–130 dBm
typ. <–130 dBm
typ. <–120 dBm
typ. <–130 dBm
typ. <–120 dBm
typ. <–115 dBm
Additional front panel connectors
USB
(two) universal serial bus connectors for connecting USB devices (USB 1.1);
two additional USB connectors at the rear panel
Optional front panel connectors
SOURCE OUT
SOURCE IN
REF OUT
REF IN
MEAS OUT
MEAS IN
output of internal source signal
input for external source signal
output of internal reference signal
input for external reference signal
output of internal measurement signal
input for external measurement signal
Display
Screen
Resolution
26 cm (10.4") diagonal color LCD
800 × 600 × 262144 pixels (high color)
Rear panel connectors
IEC BUS
remote control in line with IEEE 488, IEC 60625; 24 pins
LAN 1
first local area network connector, 8 pins, RJ-45
LAN 2
second local area network connector, 8 pins, RJ-45
USB
(two) universal serial bus connectors for connecting USB devices (USB 1.1);
two additional USB connectors at the front panel
10 MHz REF
Connector type
Input frequency
Maximum permissible deviation
Input power
alternatively input or output for external frequency reference signal
BNC, female
10 MHz
1 kHz
Input impedance
Output frequency
Output frequency accuracy
Output power
20
®
R&S ZVA Vector Network Analyzer
–3 dBm ± 8 dB
50 Ω
10 MHz
80 Hz
–3 dBm ± 8 dB at 50 Ω
Version 05.00, January 2008
DC MEAS 1 V
Connector type
Voltage range
Measurement accuracy
Resolution
Sample rate
Input impedance
DC measurement input
4-pin mini DIN, female
–1 V to +1 V
2.5 % of reading + 2.5 mV
12 bit
3 MHz
>10 kΩ
Damage voltage
DC MEAS 10 V
Connector type
Voltage range
Measurement accuracy
Resolution
Sample rate
Input impedance
30 V
DC measurement input
4-pin mini DIN, female
–10 V to +10 V
2.5 % of reading + 25 mV
12 bit
3 MHz
>10 kΩ
Damage voltage
30 V
PORT BIAS
Connector type
Maximum nominal input voltage
Maximum nominal input current
Damage voltage
Damage current
DC bias input for PORT
MONITOR
IBM-PC-compatible VGA monitor connector, 15-pin Sub-D (for external monitor)
USER CONTROL
several control and trigger signals, 25-pin Sub-D, 3.3 V TTL
for controlling external generators, for limit checks, sweep signals, etc.
pin 24 and pin 25 (inputs)
control inputs
pin 16 to pin 19 (outputs)
indicate driving port
pin 8 to pin 11 (outputs)
channel-specific user-configurable bits
pin 13 and pin 14 (outputs)
pass/fail results of limit checks
pin 4 (output)
measurements running
pin 6 (output)
ready for trigger
pin 21 (output)
control signal for external generator
pin 22 (input)
handshake signal from external generator
pin 2 (input)
trigger input for analyzer
FOOT SWITCH 1 and FOOT SWITCH 2
DRIVE PORT 1 to DRIVE PORT 4
CHANNEL BIT 0 to CHANNEL BIT 3
PASS 1 and PASS 2
BUSY
READY FOR TRIGGER
EXT GEN TRIGGER
EXT GEN BLANK
EXTERNAL TRIGGER
EXT TRIGGER
Connector type
TTL-signal (edge-triggered)
Polarity (user-selectable)
Minimum pulse width
Input impedance
Version 05.00, January 2008
BNC, female
30 V
200 mA
30 V
500 mA
trigger input for analyzer
BNC, female
3V
positive or negative
1 µs
>10 kΩ
®
R&S ZVA Vector Network Analyzer
21
Options
Generator step attenuators
Frequency range
Power range
Power accuracy
Power linearity
(with ALC off)
Dynamic range
22
®
R&S ZVA Vector Network Analyzer
®
®
®
R&S ZVA8, R&S ZVA24, and R&S ZVA40:
Generator step attenuators extend the lower limit of the output power range by 70 dB.
®
R&S ZVA50 only:
Generator step attenuators extend the lower limit of the output power range by 50 dB.
®
R&S ZVA8
300 kHz to 8 GHz
®
R&S ZVA24
10 MHz to 24 GHz
®
R&S ZVA40
10 MHz to 40 GHz
®
10 MHz to 50 GHz
R&S ZVA50
®
R&S ZVA8
300 kHz to 8 GHz
upper limit is reduced by 1 dB
300 kHz to 8 GHz
lower limit is extended by 70 dB
®
R&S ZVA24
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
10 MHz to 24 GHz
lower limit is extended by 70 dB
®
R&S ZVA40
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
24 GHz to 40 GHz
upper limit is reduced by 3 dB
10 MHz to 40 GHz
lower limit is extended by 70 dB
®
R&S ZVA50
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
24 GHz to 50 GHz
upper limit is reduced by 3 dB
10 MHz to 50 GHz
lower limit is extended by 50 dB
at –10 dBm without power calibration
identical to specifications
without optional step attenuators
®
®
R&S ZVA8, R&S ZVA24, and
®
R&S ZVA40
above –70 dBm
<2 dB
from –70 dBm to –100 dBm
<3 dB
®
R&S ZVA50
above –50 dBm
<2 dB
from –50 dBm to –80 dBm
<3 dB
®
R&S ZVA8
300 kHz to 8 GHz
is reduced by 1 dB
®
R&S ZVA24
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
®
R&S ZVA40
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 40 GHz
is reduced by 3 dB
®
R&S ZVA50
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 50 GHz
is reduced by 3 dB
Version 05.00, January 2008
Receiver step attenuators
Frequency range
Attenuation
Attenuation steps
Attenuation accuracy
Dynamic range
Noise level
Version 05.00, January 2008
These attenuators permit the level of the input signal to be attenuated in 5 dB steps up
to 35 dB.
®
R&S ZVA8
300 kHz to 8 GHz
®
R&S ZVA24
10 MHz to 24 GHz
®
R&S ZVA40
10 MHz to 40 GHz
®
10 MHz to 50 GHz
R&S ZVA50
0 dB to 35 dB
5 dB
<2 dB
®
R&S ZVA8
300 kHz to 8 GHz
is reduced by 1 dB
®
R&S ZVA24
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
®
R&S ZVA40
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 40 GHz
is reduced by 3 dB
®
R&S ZVA50
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 50 GHz
is reduced by 3 dB
®
R&S ZVA8
300 kHz to 8 GHz
is increased by 1 dB
®
R&S ZVA24
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
®
R&S ZVA40
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
24 GHz to 40 GHz
is increased by 3 dB
®
R&S ZVA50
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
24 GHz to 50 GHz
is increased by 3 dB
®
R&S ZVA Vector Network Analyzer
23
Direct generator/receiver access
Front panel connectors
Frequency range
Dynamic range
Power range
Match
Noise level
24
®
R&S ZVA Vector Network Analyzer
These options permit direct access to the internal source output as well as to the
internal reference and measurement receiver inputs via front panel connectors.
Dynamic range with direct access utilizing these inputs is stated in the “Measurement
range” section. If all the front panel jumper cables are directly connected between the
outputs and inputs, the following specifications for the vector network analyzer apply.
®
R&S ZVA8
SMA, female
®
R&S ZVA24
2.92 mm, female
®
R&S ZVA40
2.92 mm, female
®
2.4 mm, female
R&S ZVA50
®
R&S ZVA8
300 kHz to 8 GHz
®
R&S ZVA24
10 MHz to 24 GHz
®
R&S ZVA40
10 MHz to 40 GHz
®
10 MHz to 50 GHz
R&S ZVA50
®
R&S ZVA8
300 kHz to 8 GHz
is reduced by 2 dB
®
R&S ZVA24
10 MHz to 13 GHz
is reduced by 2 dB
13 GHz to 24 GHz
is reduced by 4 dB
®
R&S ZVA40
10 MHz to 13 GHz
is reduced by 2 dB
13 GHz to 24 GHz
is reduced by 4 dB
24 GHz to 40 GHz
is reduced by 6 dB
®
R&S ZVA50
10 MHz to 13 GHz
is reduced by 2 dB
13 GHz to 24 GHz
is reduced by 4 dB
24 GHz to 50 GHz
is reduced by 6 dB
®
R&S ZVA8
300 kHz to 8 GHz
upper limit is reduced by 1 dB
®
R&S ZVA24
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
®
R&S ZVA40
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
24 GHz to 40 GHz
upper limit is reduced by 3 dB
®
R&S ZVA50
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
24 GHz to 50 GHz
upper limit is reduced by 3 dB
®
R&S ZVA40
10 MHz to 4 GHz
is reduced by 2 dB
®
R&S ZVA8
300 kHz to 8 GHz
is increased by 1 dB
®
R&S ZVA24
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
®
R&S ZVA40
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
24 GHz to 40 GHz
is increased by 3 dB
®
R&S ZVA50
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
24 GHz to 50 GHz
is increased by 3 dB
Version 05.00, January 2008
General data
Temperature loading
Damp heat
Mechanical resistance
Calibration interval
EMC, RF emission
EMC, other emissions and immunity
Safety
Power supply
Power consumption
Test mark
Dimensions ( W × H × D )
Weight
Shipping weight
Version 05.00, January 2008
in line with IEC 60068-2-1 and IEC 60068-2-2
operating temperature range
5 °C to 40 °C
permissible temperature range
5 °C to 40 °C
storage temperature range
–40 °C to 70 °C
40 °C at 95 % rel. humidity,
in line with IEC 60068-2-30
vibration, sinusoidal
5 Hz to 150 Hz,
in line with IEC 60068-2-6
vibration, random
10 Hz to 300 Hz,
in line with IEC 60068-2-64
shock
40 g shock spectrum,
in line with IEC 60068-2-27, MIL-STD 810
1 year
According to EN 61000-6-4, operation is
in line with CISPR 11/EN 55011 group 1
not covered in residential, commercial,
class A (for a shielded test setup)
and business areas nor in small-size
The instrument complies with the emission
companies. Thus, the instrument must not requirements stipulated by EN 55011
be operated in residential, commercial,
class A. This means that the instrument is
suitable for use in industrial environments.
and business areas nor in small-size
companies unless additional measures are
taken to ensure that EN 61000-6-3 is met.
in line with IEC/EN 61326,
emission class B (residential
environment),
immunity industrial environment (excluding
operating frequency)
in line with IEC 61010-1, EN 61010-1, and
UL 3111-1
100 V to 240 V (AC) with tolerance ±10 %,
50 Hz to 60 Hz with tolerance ±5 %,
safety class I to VDE 411
450 W typ. 310 W (standby: typ. 10 W)
VDE, GS, CSA, CSA-NRTL/C,
CE conformity mark
465.1 mm × 286.2 mm × 495.0 mm
(18.31 in × 11.27 in × 19.49 in)
25 kg (55 lb)
37 kg (82 lb)
®
R&S ZVA Vector Network Analyzer
25
Ordering information
Designation
Vector Network Analyzer, 8 GHz, 2 ports
Vector Network Analyzer, 8 GHz, 4 ports
Vector Network Analyzer, 24 GHz, 2 ports
Vector Network Analyzer, 24 GHz, 4 ports
Vector Network Analyzer, 40 GHz, 2 ports,
2.92 mm
Vector Network Analyzer, 40 GHz, 4 ports,
2.92 mm
Vector Network Analyzer, 50 GHz, 2 ports
Vector Network Analyzer, 50 GHz, 4 ports
Options
Direct Generator/Receiver Access
®
for the R&S ZVA8 with two ports
®
for the R&S ZVA8 with four ports
®
for the R&S ZVA24 with two ports
®
for the R&S ZVA24 with four ports
®
for the R&S ZVA40 with two ports
®
for the R&S ZVA40 with four ports
®
for the R&S ZVA50 with two ports
®
for the R&S ZVA50 with four ports
Generator Step Attenuator Port 1
®
for the R&S ZVA8
®
for the R&S ZVA24
®
for the R&S ZVA40
®
for the R&S ZVA50
Generator Step Attenuator Port 2
®
for the R&S ZVA8
®
for the R&S ZVA24
®
for the R&S ZVA40
®
for the R&S ZVA50
Generator Step Attenuator Port 3
®
for the R&S ZVA8 with four ports
®
for the R&S ZVA24 with four ports
®
for the R&S ZVA40 with four ports
®
for the R&S ZVA50 with four ports
Generator Step Attenuator Port 4
®
for the R&S ZVA8 with four ports
®
for the R&S ZVA24 with four ports
®
for the R&S ZVA40 with four ports
®
for the R&S ZVA50 with four ports
26
®
R&S ZVA Vector Network Analyzer
Type
®
R&S ZVA8
®
R&S ZVA8
®
R&S ZVA24
®
R&S ZVA24
®
R&S ZVA40
Order No.
1145.1110.08
1145.1110.10
1145.1110.24
1145.1110.26
1145.1110.40
®
1145.1110.42
®
1145.1110.50
1145.1110.52
®
1164.0209.08
1164.0209.10
1164.0209.24
1164.0209.26
1164.0209.40
1164.0209.42
1164.0209.50
1164.0209.52
®
1164.0009.02
1164.0109.02
1302.5409.02
1305.5616.02
®
1164.0015.02
1164.0115.02
1302.5415.02
1305.5622.02
®
1164.0021.02
1164.0121.02
1302.5421.02
1305.5639.02
®
1164.0038.02
1164.0138.02
1302.5438.02
1305.5645.02
R&S ZVA40
R&S ZVA50
®
R&S ZVA50
R&S ZVA8-B16
®
R&S ZVA8-B16
®
R&S ZVA24-B16
®
R&S ZVA24-B16
®
R&S ZVA40-B16
®
R&S ZVA40-B16
®
R&S ZVA50-B16
®
R&S ZVA50-B16
R&S ZVA8-B21
®
R&S ZVA24-B21
®
R&S ZVA40-B21
®
R&S ZVA50-B21
R&S ZVA8-B22
®
R&S ZVA24-B22
®
R&S ZVA40-B22
®
R&S ZVA50-B22
R&S ZVA8-B23
®
R&S ZVA24-B23
®
R&S ZVA40-B23
®
R&S ZVA50-B23
R&S ZVA8-B24
®
R&S ZVA24-B24
®
R&S ZVA40-B24
®
R&S ZVA50-B24
Version 05.00, January 2008
Receiver Step Attenuator Port 1
®
for the R&S ZVA8
®
for the R&S ZVA24
®
for the R&S ZVA40
®
for the R&S ZVA50
Receiver Step Attenuator Port 2
®
for the R&S ZVA8
®
for the R&S ZVA24
®
for the R&S ZVA40
®
for the R&S ZVA50
Receiver Step Attenuator Port 3
®
for the R&S ZVA8 with four ports
®
for the R&S ZVA24 with four ports
®
for the R&S ZVA40 with four ports
®
for the R&S ZVA50 with four ports
Receiver Step Attenuator Port 4
®
for the R&S ZVA8 with four ports
®
for the R&S ZVA24 with four ports
®
for the R&S ZVA40 with four ports
®
for the R&S ZVA50 with four ports
Oven Quartz (OCXO)
Time Domain
Frequency Conversion
True Differential Mode
Pulsed Measurements
Pulsed Measurements
Pulsed Measurements with increased
recording time for 2-port models
Pulsed Measurements with increased
recording time for 4-port models
5 MHz Receiver Bandwidth
Version 05.00, January 2008
®
1164.0044.02
1164.0144.02
1302.5444.02
1305.5716.02
®
1164.0050.02
1164.0150.02
1302.5450.02
1305.5722.02
®
1164.0067.02
1164.0167.02
1302.5467.02
1305.5739.02
®
1164.0073.02
1164.0173.02
1302.5473.02
1305.5745.02
1164.1757.02
1164.1657.02
1164.1863.02
1164.1540.02
®
1164.1511.02
1164.1492.02
®
1164.1492.03
®
1164.1070.02
R&S ZVA8-B31
®
R&S ZVA24-B31
®
R&S ZVA40-B31
®
R&S ZVA50-B31
R&S ZVA8-B32
®
R&S ZVA24-B32
®
R&S ZVA40-B32
®
R&S ZVA50-B32
R&S ZVA8-B33
®
R&S ZVA24-B33
®
R&S ZVA40-B33
®
R&S ZVA50-B33
R&S ZVA8-B34
®
R&S ZVA24-B34
®
R&S ZVA40-B34
®
R&S ZVA50-B34
®
R&S ZVAB-B4
®
R&S ZVAB-K2
®
R&S ZVA-K4
®
R&S ZVA-K6
R&S ZVA-K7
®
R&S ZVA-B7
R&S ZVA-B7
R&S ZVA-K17
®
R&S ZVA Vector Network Analyzer
27
Certified Environmental System
ISO 9001
ISO 14001
DQS REG. NO 1954 QM
DQS REG. NO 1954 UM
For product brochure, see PD 5213.5680.12
and www.rohde-schwarz.com
(search term: ZVA)
¸ is a registered trademark of Rohde & Schwarz GmbH & Co. KG · Trade names are trademarks of the owners · Printed in Germany (we)
PD 5213.5680.22 · ¸ZVA · Version 05.00 · January 2008 · Data without tolerance limits is not binding · Subject to change
Certified Quality System
www.rohde-schwarz.com
Europe, Latin America, Africa, Middle East: +49 1805 124242 or +49 89 4129 13774, [email protected]
North America +1 888 837 8772, [email protected]
Asia | Pacific +65 65 130 488, [email protected]
Titel+Rueck_ZVA_dat-sw_en.indd 2
24.01.2008 09:42:38
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement