Carrier 59SC2A gas furnace offers energy efficiency of up to 92.1% AFUE and flexible installation options with its 4-way multipoise design. It features a durable aluminized-steel primary heat exchanger and a stainless steel condensing secondary heat exchanger for efficient heat transfer. The PSC blower motor, single-speed inducer motor, and single-stage gas valve ensure可靠 and efficient operation. With its compact design and self-diagnostics with SuperBrite LED, this furnace is easy to install and maintain. Stay comfortable and save on energy costs with the Carrier 59SC2A gas furnace.
advertisement
59SC2A
Comfort™ Series Single---Stage
4---Way Multipoise
Condensing Gas Furnace
Series 100
Product Data
A11263
The 59SC2 Multipoise Comfort Series Condensing Gas Furnace features energy efficiency of 92.1% AFUE gas efficiency and workhorse PSC blower motor. This gas furnace also features
4--way multipoise installation flexibility, and is available in eight model sizes. The 59SC2 can be vented for direct vent/two--pipe, ventilated combustion air, or single--pipe applications. All units meet California Air Quality Management District emission requirements, are design certified in Canada, and are certified for mobile/manufactured home use.
STANDARD FEATURES
S
4--Way multipoise design for upflow, downflow or horizontal installation.
S Installation flexibility with a 360--degree rotating elbow.
S More than twelve different venting options, including optional through--the cabinet downflow and horizontal venting.
S Ideal condensing furnace height 35” cabinet: short enough for taller coils, but still allows enough room for service.
S Silicon Nitride Power Heatt Hot Surface Igniter.
S
Aluminized--steel primary heat exchanger.
S Stainless steel condensing secondary heat exchanger.
S
High--quality corrosion--resistant prepainted steel cabinet with hemmed edges for safety.
S Factory--configured ready for upflow applications.
S
Direct--vent/sealed combustion, single--pipe venting or ventilated combustion air.
S
PSC blower motor, single--speed inducer motor, and single--stage gas valve.
S
Self--diagnostics with SuperBrite LED.
S Approved for Twinning applications (60--14 through 120--20 sizes, only)
S Propane convertible (see accessory list).
S Approved for Manufactured Housing/Mobile Home applications with MH accessory kit.
S Convenient Air Purifier and Humidifier connections.
S Residential installations may be eligible for consumer financing through the Retail Credit program.
S Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized to 1--in. water column with all present air inlets, air outlets, and condensate drain port(s) sealed.
Use of the AHRI Certified
TM
Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
C E RTI F I E D
1
SAP ORDERING NO.
59SC2A040S14--10
59SC2A060S14--10
59SC2A060S17--14
59SC2A080S17--16
CASING
DIMENSIONS (IN.)
H D W
35 29.5
14.2
35 29.5
14.2
35 29.5
17.5
35 29.5
17.5
RATED HEATING
OUTPUT†
(BTUH)
39,000
58,000
58,000
78,000
AFUE
92.1%
92.1%
92.1%
92.1%
HEATING AIRFLOW
CFM‡
820
840
980
1040
Heating
ESP
(in. WC)
0.10
0.12
0.12
0.15
COOLING CFM
@ 0.5 ESP
(in. WC)
625-905
675-1130
650-1420
810-1600
59SC2A080S21--20
59SC2A100S21--14
59SC2A100S21--20
59SC2A120S24--20
35 29.5
21.0
35 29.5
21.0
35 29.5
21.0
35 29.5
24.5
78,000
97,000
97,000
117,000
92.1%
92.1%
92.1%
92.1%
1695
1510
1680
2245
0.15
0.20
0.20
0.20
1335-1970
915-1545
1345-2065
1320-2105
† Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡ Heating CFM at factory default blower motor heating tap settings.
ESP --- External Static Pressure
FEATURES AND BENEFITS
HYBRID HEATR Dual Fuel System — This system can provide more control over your monthly energy bills by automatically selecting the most economical method of heating. With HYBRID
HEAT components, our system automatically switches between the gas furnace and the single--stage electric heat pump as outside temperatures change to maintain greater efficiency and comfort than with any traditional single-source heating system. The heat pump also delivers high-efficiency cooling in the summer.
Power Heatt Igniter — Carrier’s unique SiN igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators as do other brands. This unique feature further enhances the gas furnace reliability and continues Carrier’s tradition of technology leadership and innovation in providing a reliable and durable product.
Reliable Heat Exchanger Design — The aluminized steel, clam shell primary heat exchanger was re--engineered to achieve greater efficiency out of a smaller size. The first two passes of the heat exchanger are based on the current 80% product, a design with more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped, no-weld seam create an efficient, robust design for this essential component.
The condensing heat exchanger, a stainless steel fin and tube design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers has exceptional corrosion resistance in both natural gas and propane applications.
4-Way Multipoise Design — One model for all applications – there is no need to stock special downflow or horizontal models when one unit will do it all. The new heat exchanger design allows these units to achieve the certified AFUE in all positions.
MOTOR HP-SPEED
1/2 - 4
1/2 - 4
1/2 - 5
3/4 - 5
3/4 - 5
1/2 - 4
3/4 - 5
3/4 - 5
APPROX SHIP
WEIGHT (LB)
123
127
144
154
162
169
169
186
Direct or Single-pipe Venting, or Optional Ventilated
Combustion Air — This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air application, or in single-pipe, non-direct vent applications. This provides added flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion air from outside the furnace, which results in especially quiet operation. By sealing the entire combustion vestibule, the entire furnace can be made quieter, not just the sound of the burners.
Monoport Burners — The burners are specially designed and finely tuned for smooth, quiet combustion and economical operation.
Bottom Closure — Factory-installed for side return; easily removable for bottom return. The multi-use bottom closure can also serve for roll-out protection in horizontal applications, and act as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch — Automatically shuts off 115-v power to furnace whenever blower access panel is opened.
Quality Registration — Our furnaces are engineered and manufactured under an ISO 9001 registered quality system.
Certifications — This furnace is CSA (AGA and CGA) design certified for use with natural and propane gases. The furnace is factory--shipped for use with natural gas. A CSA listed gas conversion kit is required to convert furnace for use with propane gas. The efficiency is AHRI efficiency rating certified. This furnace meets California Air Quality Management District emission requirements.
2
SPECIFICATIONS
Heating Capacity and Efficiency
Input High Heat
High Heat Output
Efficiency
Certified Temperature
Rise Range ºF (ºC)
040-10 060-10 060-14 080-16 080-20 100-14 100-20
(BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000
(BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000
AFUE % (ICS) 92.1
92.1
92.1
92.1
92.1
92.1
92.1
High Heat
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
Airflow Capacity and Blower Data
Certified External Static
Pressure (in. w.c.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
Air Filtration System
Filter Used for Certified Watt Data*
040-10 060-10 060-14 080-16 080-20 100-14 100-20
Heating 0.10
0.12
0.12
0.15
0.15
0.20
0.20
Cooling
High Heat
Cooling
0.5
820
905
0.5
840
1130
0.5
980
1420
0.5
1040
1600
0.5
1695
1970
0.5
1510
1545
0.5
1680
2065
400 CFM/ton
350 CFM/ton
2
2.5
0.5
6.2
2.5
3
0.5
6.2
3.5
4
0.5
6.8
4
4.5
5
5.5
4
4.5
Permanent Split Capacitor (PSC)
0.75
0.75
0.5
7.9
13.8
6.5
5
6
0.75
13.8
in.
4
11 x 7
4
11 x 7
5
11 x 8
5
500 - 1150
5 4 5
11 x 8 11 x 10 11 x 10 11 x 10
Field Supplied
KGAWF**06UFR
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
Volts-Hertz-Phase
Min-Max
Amps
040-10 060-10 060-14 080-16 080-20 100-14 100-20
115-60-1
6.8
7.0
8.4
9.6
104-127
14.5
7.6
14.6
Amps
AWG
9.5
14
Feet 39
(M) (11.9)
9.7
14
38
(11.6)
11.5
14
32
(9.8)
13.0
14
28
(8.5)
19.1
12
30
(9.1)
10.4
14
35
(10.7)
19.2
12
29
(8.8)
Amps 15 15 15 15 20 15 20
External Control Power Available
Heating
Cooling
40 VA
27.9 VA
34.6 VA
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant) Manufacturer
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Gas Conversion Kit - Natural to Propane
Gas Conversion Kit - Propane to Natural
Manufactured (Mobile) Home Kit
Ignition Device
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections
* See Accessory List for part numbers available.
040-10 060-10 060-14 080-16 080-20 100-14 100-20
2 3 3 4
1/2" - NPT
4
White Rogers
4.5
13.6
5 5
165 165 180
KGANP50011SP
KGAPN42011SP
KGAMH0601KIT
Silicon Nitride
170 200 180
Adjustable: 90, 120, 150, 180 seconds
90 seconds none
Com 24V, R, W, G, Y
EAC (115vac); HUM (24vac)
180
120-20
120,000
117,000
92.1
40 - 70
(22 - 39)
120-20
0.20
0.5
2245
2105
5
6
0.75
14.1
5
11 x 11
120-20
14.9
19.6
12
29
(8.8)
20
120-20
6
160
3
1 - 2
Family
59
3
Htg. Stages
T
4
Tier
N
Family
S - Single Stage
T - Two Stage
M - Modulating
C - Comfort
P - Performance
N - Infinity
MODEL NUMBER NOMENCLATURE
Example of Model Number
5
Base Effy.
6
6
Major Series
A
7 - 9
Htg. Cap.
060
10
Motor
V
11 - 12
Width
17
0 - +90 AFUE
2 - +92 AFUE
3 - +93 AFUE
5 - +95 AFUE
6 - +96 AFUE
7 - +97 AFUE
Major Series
040=40,000 BTU
060=60,000 BTU
080=80,000 BTU
100=100,000 BTU
120=120,000 BTU
140=140,000 BTU
S - Standard
E - Energy Efficient
V - Variable Speed
14 - 14.2”
17 - 17.5”
21 - 21.0”
24 - 24.5”
Not all familes have these models.
13
Voltage
--
Voltage
14
Minor Series
--
15 - 16
Airflow
14
08 - 800 CFM
10 - 1000 CFM
12 - 1200 CFM
14 - 1400 CFM
16 - 1600 CFM
18 - 1800 CFM
20 - 2000 CFM
22 - 2200 CFM
Minor Series
A12373
FURNACE COMPONENTS
GAS BURNER
HOT SURFACE
IGNITER
MANUAL RESET
ROLLOUT SWITCH
FLAME
SENSOR
MANUAL RESET
ROLLOUT SWITCH
GAS VALVE
OPERATING INSTRUCTIONS
NOT SHOWN (LOCATED ON
MAIN FURNACE DOOR, SEE
OPERATING INSTRUCTIONS
INSIDE DOOR FIGURE).
ELECTRICAL JUNCTION
BOX (IF REQUIRED,
LOCATION MAY VARY)
BLOWER DOOR
SAFETY SWITCH
FURNACE
CONTROL
BOARD
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
INDUCER MOTOR
ASSEMBLY
MEDIA CABINET
BLOWER AND
MOTOR
CAPACITOR/
POWER CHOKE
(IF USED)
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
A11408
4
DESCRIPTION
Venting Accessories
Vent Kit - Through the Cabinet
Vent Terminal - Concentric - 2” (51 mm)
Vent Terminal - Concentric - 3” (76 mm)
Vent Terminal Bracket - 2” (51 mm)
Vent Terminal Bracket - 3” (76 mm)
Vent Kit --- Rubber Coupling
Condensate Drainage Accessories
Freeze Protect Kit - Heat Tape
CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVC
Horizontal Trap Grommet - Direct Vent
Condensate Neutralizer Kit
External Trap Kit
Ductwork Adapter Accessories
Furnace Base Kit for Combustible Floors
Coil Adapter Kits --- No Offset
Coil Adapter Kits --- Single Offset
Coil Adapter Kits --- Double Offset
Return Air Base (Upflow Applications) 14.0---in. wide
Return Air Base (Upflow Applications) 17.5---in. wide
Return Air Base (Upflow Applications) 21.0---in. wide
Return Air Base (Upflow Applications) 24.5---in. wide
IAQ Device Duct Adapters 20.0---in. IAQ to 16 in. Side Return
IAQ Device Duct Adapters 24.0---in. IAQ to 16 in. Side Return
Gas Conversion Accessories
Mobile Home Kit
Gas Conversion Kit - Nat to LP
Gas Conversion Kit - LP to Nat
Gas Orifice Kit - #42 (Nat Gas)
Gas Orifice Kit - #43 (Nat Gas)
Gas Orifice Kit - #44 (Nat Gas)
Gas Orifice Kit - #45 (Nat Gas)
Gas Orifice Kit - #46 (Nat Gas)
Gas Orifice Kit - #47 (Nat Gas)
Gas Orifice Kit - #48 (Nat Gas)
Gas Orifice Kit - #54 (LP)
Gas Orifice Kit - #55 (LP)
Gas Orifice Kit - #56 (LP)
Gas Orifice Kit - 1.25mm (LP)
Gas Orifice Kit - 1.30mm (LP)
Control Accessories
Twinning Kit
IAQ Accessories
Filter Rack --- Side Return for 1” Filters
Filter Rack --- Bottom Return for 1” Filters --- 14.2” wide
Filter Rack --- Bottom Return for 1” Filters --- 17.5” wide
Filter Rack --- Bottom Return for 1” Filters --- 21.0” wide
Filter Rack --- Bottom Return for 1” Filters --- 24.5” wide
Filter Pack (6 pack) --- Washable - 16x25x1
Filter Pack (6 pack) --- Washable - 24x25x1
EZ-Flex Filter - 16” (406 mm)
EZ-Flex Filter - 20” (508 mm)
EZ-Flex Filter - 24” (610 mm)
EZ-Flex Filter with End Caps - 16” (406 mm)
EZ-Flex Filter with End Caps - 20” (508 mm)
EZ-Flex Filter with End Caps - 24” (610 mm)
Cartridge Media Filter - 16” (406 mm)
Cartridge Media Filter - 20” (508 mm)
Cartridge Media Filter - 24” (610 mm)
EZ Flex Cabinet Side or Bottom Return 4” Filters --- 16”
EZ Flex Cabinet Side or Bottom Return 4” Filters --- 20”
EZ Flex Cabinet Side or Bottom Return 4” Filters --- 24”
D
= Used with the model furnace
KGAFR0801SRE
KGBFR0401B14
KGBFR0501B17
KGBFR0601B21
KGBFR0701B24
KGAWF1306UFR
KGAWF1506UFR
EXPXXFIL0016
EXPXXFIL0020
EXPXXFIL0024
EXPXXUNV0016
EXPXXUNV0020
EXPXXUNV0024
FILXXCAR0016
FILXXCAR0020
FILXXCAR0024
EZXCABCC0016
EZXCABCC0020
FILCABXL0024
ACCESSORIES
PART NUMBER 040---10 060---10 060---14 080---16 080---20 100-14 100-20 120-20
KGADC0101BVC
KGAVT0701CVT
KGAVT0801CVT
KGAVT0101BRA
KGAVT0201BRA
KGAAC0101RVC
KGAHT0101CFP
KGAAD0110PVC
KGACK0101HCK
P908---0001
KGAET0201ETK
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D D
See Venting Tables
See Venting Tables
D D
D D
All DV Horizontal
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
KGASB0201ALL
KGADA0101ALL
KGADA0201ALL
KGADA0301ALL
KGARP0301B14
KGARP0301B17
KGARP0301B21
KGARP0301B24
KGAAD0101MEC
KGAAD0201MEC
KGAMH0601KIT
KGANP50011SP
KGAPN42011SP
LH32DB207
LH32DB202
LH32DB200
LH32DB205
LH32DB208
LH32DB078
LH32DB076
LH32DB203
LH32DB201
LH32DB206
LH32DB209
LH32DB210
KGATW0701HSI
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D D
D
20”x25” IAQ Devices
24”x25” IAQ Devices
D D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D D D
Use with EZXCAB---1016
Use with EZXCAB---1020
Use with EZXCAB---1024
Use with EZXCAB---1016
Use with EZXCAB---1020
Use with EZXCAB---1024
Use with FILCABXL ---1016
Use with FILCABXL ---1020
Use with FILCABXL ---1024
D D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
5
UNIT
SIZE
040---10
060---10
060---14
080---16
080---20
100---14
100---20
120---20
1085
2415
2130
1830
1690
1840
1705
1425
1750
1550
1290
1415
2440
2300
1805
1560
1390
1870
1525
1375
1045
880
2360
2100
845
770
1665
1340
1050
985
735
0.1
1100
955
820
730
1340
1035
SPEED
TAPS 2
Black
Yellow
Orange
Blue
Red 5
Black
Yellow
Orange
Blue
Red
Black
Blue
Yellow
Red 5
Black
Yellow
Orange
Blue
Red
Black
Blue
Yellow
Orange 5
Red 5
Black
Yellow
Blue
Red
Black
Yellow
Blue
Red 5
Black
Yellow
Orange
Blue
Red 5
AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)
RETURN-AIR
CONNECTION
SIDE/BOTTOM
SIDE/BOTTOM
SIDE/BOTTOM
SIDE/BOTTOM
BOTTOM or
TWO-SIDES 3,4
SIDE/BOTTOM
BOTTOM or
TWO-SIDES 3,4
BOTTOM or
TWO-SIDES 3,4
1010
2245
2010
1785
1655
1765
1660
1385
1660
1470
1220
1390
2295
2185
1750
1535
1370
1740
1460
1330
1030
850
2160
1960
960
2155
1945
1740
1620
1725
1615
1365
1605
1430
1180
1370
2215
2090
1705
1505
1345
1670
1415
1300
1010
835
2065
1885
1045
2330
2075
1815
1680
1810
1685
1410
1705
1510
1255
1405
2360
2245
1780
1550
1385
1810
1495
1355
1040
865
2250
2030
710
1295
1010
825
750
1615
1320
1045
980
720
0.2
1055
EXTERNAL STATIC PRESSURE (IN.W.C.)
0.3
1010
0.4
960
0.5
905
0.6
850
0.7
795
915
795
875
765
830
730
790
695
740
655
695
615
680
1245
980
810
730
1550
1295
1035
975
700
655
1190
945
785
710
1485
1260
1015
950
675
625
1130
910
755
675
1420
1215
995
930
650
595
1065
865
710
640
1345
1165
960
900
620
555
1005
795
670
600
1270
1110
915
845
595
915
2065
1865
1685
1580
1665
1570
1335
1545
1380
1130
1345
2105
2005
1650
1470
1320
1600
1365
1260
985
810
1970
1805
865
1965
1785
1625
1530
1590
1510
1290
1475
1320
1075
1305
1975
1855
1595
1420
1285
1525
1305
1210
960
785
1880
1720
805
1865
1695
1550
1465
1515
1445
1245
1405
1245
1020
1260
1815
1745
1515
1360
1230
1440
1240
1155
920
750
1785
1635
740
1760
1600
1470
1385
1430
1370
1190
1305
1170
960
1200
1710
1635
1430
1285
1175
1355
1170
1090
875
715
1685
1545
625
560
1190
1045
845
795
560
0.8
740
645
570
515
895
730
595
1530
1375
1255
1185
1240
1135
1050
1140
1015
800
1050
1405
1370
1230
1130
1035
1180
990
940
745
605
1455
1305
515
455
985
850
725
690
480
1.0
620
530
460
400
725
605
665
1645
1490
1370
1295
1335
1280
1120
1220
1095
885
1125
1575
1505
1330
1205
1105
1270
1090
1025
825
665
1580
1440
570
510
1105
925
785
740
520
0.9
685
590
515
465
815
665
NOTE:
1. A filter is required for each return ---air inlet. Airflow performance includes a 3/4---in. (19 mm) washable filter media such as contained in a factory---authorized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c.. available external static pressure.
2. Blower speed taps are not always in the same order. Factory default blower connections are as follows: a. Heating airflow --- BLUE (also used for Continuous Fan) b. Cooling airflow --- BLACK (enabled when the Y terminal is energized)
ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION.
3. Airflows over 1800 CFM require bottom return, two---side return, or bottom and side return. A minimum filter size of 20” x 25” (508 x 635 mm) is required.
4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
5. Highlighted areas indicate that this airflow range is beyond the range allowed for heating. THESE AIRFLOW RANGES MAY ONLY BE USED FOR COOL-
ING.
6
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M)
Table 1 – Maximum Equivalent Vent Length -- Ft. (M)
0 to 4500 Ft. (0 to 1370 M) Altitude
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Altitude
FT (M)
Unit Size
BTU/Hr
DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE)
0 to 2000
(0 to 610)
2001 to 3000
(610 to 914)
40,000
60,000
80,000
3
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
3001 to 4000
(914 to 1219)
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
36
21
4001 to 4500
(1219 to 1370)
80,000
100,000
14
NA
120,000
140,000 4
NOTES: See notes at end of venting tables.
See Table 3 for altitudes over 4500 ft. (1370 M)
NA
NA
39
23
15
NA
NA
NA
50
30
20
NA
NA
NA
45
27
17
NA
NA
NA
1-1/2
(15.2)
(9.1)
(6.1)
(13.7)
(8.2)
(5.2)
(11.9)
(7.0)
(4.6)
(11.0)
(6.4)
(4.3)
210
135
70
25
NA
NA
198
127
64
22
NA
NA
184
119
59
19
NA
NA
177
115
56
17
NA
NA
2
(64.0)
(41.1)
(21.3)
(7.6)
(60.4)
(38.7)
(19.5)
(6.7)
(56.1)
(36.3)
(18.0)
(5.8)
(53.9)
(35.1)
(17.1)
(5.2)
214
210
155
98
8
NA
205
204
150
94
NA
NA
Vent Pipe Diameter (in.) 1
2-1/2
250
235
175
110
15
10
232
222
165
104
11
NA
(76.2)
(71.6)
(53.3)
(33.5)
(4.6)
(3.0)
(70.7)
(67.7)
(50.3)
(31.7)
(3.4)
NA 2
265
235
235
100
90
NA
250
222
223
93
80
(65.2)
(64.0)
(47.2)
(29.9)
(2.4)
(62.5)
(62.2)
(45.7)
(28.7)
NA
235
210
211
86
79
NA
228
202
205
83
69
3
(80.8)
(71.6)
(71.6)
(30.5)
(27.4)
(76.2)
(67.7)
(68.0)
(28.3)
(24.4)
(71.6)
(64.0)
(64.3)
(26.2)
(24.1)
(69.5)
(61.6)
(62.5)
(25.3)
(21.0)
4
(80.8)
(80.8)
(76.2)
(64.0)
(75.9)
(76.2)
(72.2)
(56.4)
(70.7)
(71.9)
(68.3)
(48.2)
(68.3)
(69.8)
(66.1)
(44.5)
NA
NA
232
236
224
158
NA
NA
224
229
217
146
NA
NA
265
265
250
210
NA
NA
249
250
237
185
ELBOW CONFIGURATIONS VENT TERMINAL CONFIGURATIONS
Concentric
Long Medium Mitered
Pipe Diameter (in):
Mitered 90º Elbow
Medium Radius 90º Elbow
Long Radius 90º Elbow
Mitered 45º Elbow
Medium Radius 45º Elbow
Long Radius 45º Elbow
Tee
Concentric Vent Termination
Standard Vent Termination
Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
1-1/2 2 2-1/2 3
4
2.5
1.5
16
8
5
3
0
NA
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
(0.0)
4
2.5
1.5
16
0
0
8
5
3
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
(0.0)
(0.0)
4
2.5
1.5
16
8
5
3
0
NA
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
(0.0)
4
2.5
1.5
16
0
0
8
5
3
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
(0.0)
(0.0)
Standard
A11580
4
2.5
1.5
16
8
5
3
0
4
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
NA
(0.0)
7
Venting System Length Calculations
The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 2.
Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.
See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.
Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Tables 1 and 3.
Example 1
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M). Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a factory accessory concentric vent kit.
Can this application use 2--in. (50 mm ND) PVC/ABS DWV vent piping?
Measure the required linear length of air inlet and vent pipe; insert the longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the vent or inlet pipe)
3 x 3 ft
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the vent or inlet pipe)
Add equiv length of vent termination
2 x 1.5 ft
Add correction for flexible vent pipe, if any
Total Equivalent Vent Length (TEVL)
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
=
100 ft
9 ft.
= 3 ft.
0 ft.
0 ft.
112 ft.
127 ft.
YES
Use length of the longer of the vent or air inlet piping system
From Table 2
From Table 2
From Table 2
From Vent Manufacturer’s instructions; zero for PVC/ABS DWV
Add all of the above lines
For 2” pipe from Table 1
Therefore, 2” pipe may be used
Example 2
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M) Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6 M) of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.
Assume that one meter of flexible 60 mm or 80 mm polypropylene pipe equals 2 Meters of PVC/ABS pipe. VERIFY FROM VENT
MANUFACTURER’S INSTRUCTIONS.
Can this application use 60 mm (O.D.) polypropylene vent piping? If not what size piping can be used?
Measure the required linear length of air inlet and vent pipe; insert the longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the vent or inlet pipe)
3 x 3 ft
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the vent or inlet pipe)
Add equiv length of vent termination
Add correction for flexible vent pipe, if any
Total Equivalent Vent Length (TEVL)
0
9 M
1.8
x x x
3 ft/M
20 ft
=
=
=
=
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
100 ft
9 ft.
0 ft.
18 ft.
36 ft.
163 ft.
127 ft.
NO
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
Use length of the longer of the vent or air inlet piping system
From Vent Manufacturer’s instructions
250 ft.
YES
From Vent Manufacturer’s instructions
From Vent Manufacturer’s instructions
From Vent Manufacturer’s instructions
Add all of the above lines
For 2” pipe from Table 1
Therefore, 60mm pipe may NOT be used; try 80 mm
For 3” pipe from Table 1
Therefore, 80 mm pipe may be used
8
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M) (CONTINUED)
Table 3 – Maximum Equivalent Vent Length -- Ft. (M)
4501 to 10,000 Ft. (0 to 1370 M) Altitude
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Altitude
FT (M) 5
4501 to 5000
(1370 to 1524)
5001 to 6000
(1524 to 1829)
6001 to 7000
(1829 to 2134)
7001 to 8000
(2134 to 2438)
8001 to 9000
(2438 to 2743)
9001 to 10,000
(2743 to 3048)
Unit Size
40,000
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
171
133
89
40
NA
NA
NA
121
82
35
NA
NA
NA
110
76
31
NA
NA
NA
158
103
49
12
NA
NA
145
96
44
10
NA
NA
111
54
16
NA
NA
33
15
10
NA
NA
NA
NA
10
7
NA
NA
NA
NA
5
NA
NA
NA
NA
NA
27
16
11
NA
NA
NA
21
13
NA
NA
NA
NA
20
13
NA
NA
NA
1-1/2
(10.1)
(6.1)
(4.0)
(8.2)
(4.9)
(3.4)
(6.4)
(4.0)
(4.6)
(3.0)
(3.0)
(2.1)
(1.5)
DIRECT VENT (2-PIPE) AND SINGLE-PIPE
Vent Pipe Diameter (in.) 1
2 2-1/2 3
(52.1) 196 (59.7) NA
2
(33.8)
(16.5)
(4.9)
198
146
91
NA
NA
(60.4)
(44.5)
(27.7)
221
195
200
80
60
(67.4)
(59.4)
(61.0)
(24.4)
(18.3)
(48.2)
(31.4)
(14.9)
(3.7)
(44.2)
(29.3)
(13.4)
(3.0)
(40.5)
(27.1)
(12.2)
(36.9)
(25.0)
(10.7)
(33.5)
(23.2)
(9.4)
146
163
120
73
NA
NA
130
152
111
67
NA
NA
115
142
103
62
NA
NA
179
186
137
85
NA
NA
162
174
120
79
NA
NA
(54.6)
(56.7)
(41.8)
(25.9)
(49.4)
(53.0)
(36.6)
(24.1)
(44.5)
(49.7)
(36.6)
(22.3)
(39.6)
(46.3)
(33.8)
(20.4)
(35.1)
(43.3)
(31.4)
(18.9)
(63.1)
(55.8)
(57.3)
(22.6)
(15.2)
(59.1)
(52.1)
(54.3)
(20.7)
(12.5)
(55.2)
(48.5)
(50.9)
(18.9)
(9.8)
(51.2)
(45.1)
(47.9)
(17.1)
(7.0)
(47.5)
(41.8)
(44.8)
(15.5)
(4.9)
NA
181
159
167
62
32
NA
168
148
157
56
23
NA
156
137
147
51
16
NA
207
183
188
74
50
NA
194
171
178
68
41
4
(65.8)
(67.7)
(64.3)
(40.8)
(61.0)
(63.4)
(60.7)
(33.2)
(56.4)
(59.4)
(57.0)
(26.5)
(51.8)
(55.5)
(53.3)
(19.2)
(47.5)
(51.8)
(50.0)
(12.8)
(43.3)
(47.9)
(46.6)
(6.1)
NA
NA
NA
170
182
175
63
NA
NA
156
170
164
42
NA
NA
142
157
153
20
NA
NA
200
208
199
109
NA
NA
185
195
187
87
NA
216
222
211
134
NOTES:
1. Use only the vent pipe sizes shown for each furnace. It is NOT necessary to choose the smallest diameter pipe possible for venting.
2. NA --- Not allowed. Pressure switch will not close, or flame disturbance may result.
3. Total equivalent vent lengths under 10’ for 40,000 BTUH furnaces from 0 to 2000 ft. (0 to 610 M) above sea level require use of an outlet choke plate .
Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout.
4. Not all furnace families include 140,000 BTUH input models.
5. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction.
6. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
7. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
8. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
9. The minimum pipe length is 5 ft. (1.5 M) linear feet (meters) for all applications.
10. Use 3---in. (76 mm) diameter vent termination kit for installations requiring 4---in. (102 mm) diameter pipe.
9
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE -- FT. (M)
Single Stage
Furnace
Input
40000
Winter Design
Temp ° F (° C)
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
Ft.
M
Ft.
M
Ft.
M
Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M)
Pipe
Length in
Ft. & M
No Insulation
Pipe Diameter-inches (mm)
1 1/2 2 2 1/2 3 4
3/8-in. (9.5 mm) Insulation
Pipe Diameter-inches (mm)
1 1/2 2 2 1/2 3 4
Ft.
M
1/2-in. (12.7 mm) Insulation
Pipe Diameter-inches (mm)
1 1/2 2 2 1/2 3 4
(38) (51) (64) (76) (102) (38) (51) (64) (76) (102) (38) (51) (64) (76) (102)
48 42 42 N/A N/A 50 122 111 N/A N/A 50 144 130 N/A N/A
14.6
12.8
12.8
N/A N/A 15.2
37.2
33.8
N/A N/A 15.2
43.9
39.6
N/A N/A
25
7.6
14
4.3
7
2.1
19
5.8
7
2.1
0
0.0
17
5.2
5
1.5
0
0.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
50
15.2
50
15.2
50
15.2
75
22.9
52
15.8
38
11.6
66
20.1
45
13.7
31
9.4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
50
15.2
50
15.2
50
15.2
90
27.4
64
19.5
48
14.6
79
24.1
55
16.8
40
12.2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
60000
80000
100000
120000
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
140000
-20 (-30)
-40 (-40)
*Not all families have these models.
Ft.
M
Ft.
M
Ft.
M
Ft.
M
Ft.
M
Ft.
Ft.
M
Ft.
M
M
Ft.
M
Ft.
M
Ft.
M
Ft.
M
M
Ft.
M
Ft.
Ft.
M
Ft.
M
M
Ft.
M
Ft.
M
Ft.
Ft.
M
30 61 61 54 N/A
9.1
18.6
18.6
16.5
N/A
30 31 30 23 N/A
9.1
24
7.3
15
4.6
9.4
17
5.2
8
2.4
9.1
15
4.6
5
1.5
7.0
7
2.1
0
0.0
N/A
N/A
N/A
N/A
N/A
30 135 163 142
9.1
41.1
49.7
43.3
30 113 100 85
9.1
34.4
30.5
25.9
30 81 70 57
9.1
24.7
21.3
17.4
30 61 52 40
9.1
18.6
15.8
12.2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
30 135 191 166
9.1
41.1
58.2
50.6
30 135 120 101
9.1
41.1
36.6
30.8
30 98 85 70
9.1
29.9
25.9
21.3
30 75 64 51
9.1
22.9
19.5
15.5
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
20 70 78 70 60 20 70 175 183 154 20 70 175 215 181
6.1
21.3
23.8
21.3
18.3
6.1
21.3
53.3
55.8
46.9
6.1
21.3
53.3
65.5
55.2
20 42 41 33 21 20 70 132 111 89 20 70 157 133 107
6.1
12.8
12.5
10.1
6.4
20 25 23 14 1
6.1
20
7.6
14
7.0
12
4.3
3
0.3
0
6.1
4.3
3.7
0.9
0.0
6.1
20
6.1
21.3
70
21.3
40.2
94
21.6
33.8
77
17.1
27.1
57
11.6
6.1
20
6.1
21.3
70
21.3
47.9
113
26.2
40.5
94
21.3
32.6
71
6.1
21.3
28.7
23.5
17.4
6.1
21.3
34.4
28.7
21.6
20 70 71 56 38 20 70 86 70 50
15.2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
25 99 89 78 N/A
7.6
30.2
27.1
23.8
N/A
25 55 46 33 N/A
7.6
16.8
14.0
10.1
N/A
25 34 24
7.6
10.4
7.3
23 20 11
7.0
6.1
3.4
11
3.4
0
0.0
N/A
N/A
N/A
N/A
25
7.6
25
7.6
25
7.6
25
7.6
110 233 265 N/A
33.5
71.0
80.8
N/A
110 145 117 N/A
33.5
44.2
35.7
N/A
110 103 79 N/A
33.5
31.4
24.1
N/A
95 77 55 N/A
29.0
23.5
16.8
N/A
25
7.6
25
7.6
25
7.6
25
7.6
110 235 229
33.5
71.6
69.8
110 173 140
33.5
52.7
42.7
110 124 97
33.5
37.8
29.6
110 94 70
33.5
28.7
21.3
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
15
4.6
15
4.6
15 99 86 N/A N/A
4.6
30.2
26.2
N/A N/A
15 51 38 N/A N/A
4.6
15.5
11.6
N/A N/A
28
8.5
14
4.3
14
4.3
0
0.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
15
4.6
15
4.6
15
4.6
15
4.6
100 219 N/A
30.5
66.8
N/A
100 130 N/A
30.5
39.6
N/A
100 88 N/A
30.5
26.8
N/A
85 62 N/A
25.9
18.9
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
15
4.6
15
4.6
15
4.6
15
4.6
100 250
30.5
76.2
100 156
30.5
47.5
100 108
30.5
32.9
100 79
30.5
24.1
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
10 90 99 N/A N/A
3.0
27.4
30.2
N/A N/A
10 61 47 N/A N/A
3.0
18.6
14.3
N/A N/A
10 35 21
3.0
10.7
6.4
10
3.0
20
6.1
NA
NA
N/A N/A
N/A N/A
N/A N/A
N/A N/A
10
3.0
10
3.0
10
3.0
10
3.0
90 210 N/A
27.4
64.0
N/A
90 153 N/A
27.4
46.6
N/A
90 104 N/A
27.4
31.7
N/A
90 75 N/A
27.4
22.9
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10
3.0
10
3.0
10
3.0
10
3.0
90 210
27.4
64.0
90 183
27.4
55.8
90 128
27.4
39.0
90 94
27.4
28.7
10
RETURN AIR TEMPERATURE
This furnace is designed for continuous return--air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
80 / 27˚C
SUPPLY AIR
60 / 16˚C
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITION
Rear
Front (Combustion air openings in furnace and in structure)
Required for service**
All Sides of Supply Plenum**
Sides
Vent
Top of Furnace
* Recommended
**Consult your local building codes
CLEARANCE
0 (0 mm)
1 in. (25 mm)
24 in. (610 mm)*
1 in. (25 mm)
0 (0 mm)
0 (0 mm)
1 in. (25 mm)
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
MITERED RADIUS
PVC 90
°
ELBOW
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC PIPE
A10490
12” (300 mm) MINIMUM
NOTE: See Installation Instructions for specific venting configurations.
11
A12376
A
DOWNFLOW SUBBASE
LOCATING
TAB
1 1 /4-IN. TYP
PLENUM
OPENING
B
D
LOCATING
TAB
1
2
3
4
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
C
A97427
Assembled
Disassembled
FURNACE
CASING WIDTH
FURNACE IN DOWNFLOW
APPLICATION
DIMENSIONS (IN. / MM)
PLENUM OPENING*
A B
FLOOR OPENING
C D
14---3/16 (360)
17---1/2 (445)
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
11---3/16
(322)
15---1/8
(384)
19 (483)
19 (483)
13---7/16
(341)
16---3/4
(426)
21 (533)
24---1/2 (622)
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
18---5/8
(396)
22---1/8
(562)
19 (483)
19 (483)
20---1/4
(514)
23---3/4
(603)
*The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
20---5/8
(600)
20---5/8
(600)
20---5/8
(600)
20---5/8
(600)
4
3
2
1
A88207
HOLE NO. FOR
WIDTH
ADJUSTMENT
4
3
2
1
Concentric Vent Kit
A93086
A concentric vent kit allows vent and combustion--air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe.
Downflow Subbase
A88202
One base fits all furnace sizes. The base is designed to be installed between the furnace and a combustible floor when no coil box is used or when a coil box other than a Carrier cased coil is used. It is
CSA design certified for use with Carrier branded furnaces when installed in downflow applications.
12
23-5/8"
(600mm)
23-3/8”
(594mm)
MEDIA FILTER CABINET
25-5/8"
(651mm)
24-1/4”
(616mm)
Opening with Flanges Bent
23-1/8”
(588mm)
Opening
A
Furnace Side Duct Side
23-3/4”
(603mm)
Centerline Screw Slots
5 3
4
"
(146mm)
Media Filter
Cabinet
16" (406mm)
20" (508mm)
24" (610mm)
A
17" (432mm)
21" (533mm)
25" (635mm)
B
16" (406mm)
20" (508mm)
24" (610mm)
NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return.
A12428
GND
115-V FIELD-
SUPPLIED
DISCONNECT
TYPICAL WIRING SCHEMATIC
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
FIVE WIRE
THREE-WIRE
HEATING-ONLY
BLOWER DOOR SWITCH
NOTE 2
W C R
BLK
WHT
BLK
WHT
GND
AUXILIARY
J-BOX
W
R
O
L
C
O
N
T
R
G
COM
Y
24-V
TERMINAL
BLOCK
FURNACE
NOTE 1
G Y
THERMOSTAT
TERMINALS
TWO
WIRE
CONDENSING
UNIT
FIELD-SUPPLIED
DISCONNECT
GND
208/230- OR
460-V
THREE
PHASE
208/230-V
SINGLE
PHASE
NOTES: 1.
2.
3.
Connect Y-terminal in furnace as shown for proper blower operation.
Some thermostats require a "C" terminal connection as shown.
If any of the original wire, as supplied, must be replaced, use same type or equivalent wire.
A11387
13
DIMENSIONAL DRAWING
59SC2
FURNACE SIZE
040--- 10
060--- 10
060--- 14
080--- 16
080--- 20
100--- 14
100--- 20
120--- 20
A
CABINET WIDTH
14--- 3/16 (361)
17--- 1/2 (445)
21 (533)
24--- 1/2 (622)
B
OUTLET WIDTH
12--- 1/2 (319)
15--- 7/8 (403)
19--- 3/8 (492)
22--- 7/8 (581)
C
BOTTOM INLET WIDTH
12--- 9/16 (322)
16 (406)
14
19--- 1/2 (495)
23 (584)
D
AIR INTAKE
7--- 1/8 (181)
8--- 3/4 (222)
10--- 1/2 (267)
12--- 1/4 (311)
SHIP WT.
LB (KG)
123.0 (55.4)
127.0 (57.2)
144.0 (64.8)
154.0 (69.3)
161.5 (72.7)
168.5 (75.8)
168.5 (75.8)
186.0 (83.7)
A12267
GUIDE SPECIFICATIONS
General
System Description
Furnish a ______________________ 4--way multipoise gas--fired condensing furnace for use with natural gas or propane (factory-authorized conversion kit required for propane).
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will carry the CSA Blue StarR and Blue FlameR labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and PSC Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of PSC type shall be permanently lubricated with sleeve bearings, of _______hp, and have multiple speeds from 500--1150 RPM operating only when
115--VAC motor inputs are provided. Blower motor shall be direct drive and soft mounted to the blower housing to reduce vibration transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted galvanized steel.
Draft Inducer Motor
Draft inducer motor shall be single--speed PSC design.
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass corrosion--resistant aluminized steel of fold--and--crimp sectional design and applied operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a stainless steel flow--through of fin--and--tube design and applied operating under negative pressure.
Controls
Controls shall include a micro--processor--based integrated electronic control board with at least 16 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self--test feature that checks all major functions of the furnace, and a replaceable automotive--type circuit protection fuse. Multiple operational settings available, including blower speeds for heating, cooling. Continuous fan speed is the same as the selected heating speed.
Operating Characteristics
Heating capacity shall be _________________ Btuh input;
______________ Btuh output capacity.
Fuel Gas Efficiency shall be __________AFUE.
Air delivery shall be ________________ cfm minimum at 0.50 in.
W.C. external static pressure.
Dimensions shall be: depth_________in.
(mm); width
__________in. (mm); height___________in. (mm) (casing only).
Height shall be_________in. (mm) with A/C coil and
_________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size of HACR--type designated circuit breaker shall be _________ amps.
Special Features
Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements.
15
Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 09/12
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
16
Catalog No: 59SC2A---02PD
Replaces: 59SC2A--- 01PD
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project