奇 恩 電 子

奇 恩 電 子
奇恩電子股份有限公司
GENTLE WAYEER ELECTRIC CO., LTD.
APPROVAL SHEET
客戶名稱
Customer
產品名稱
Description
GN-009EN
客戶產品編號
Customer P/N
產品編號
P/N
Gentle Wayeer Electric Co., Ltd. Certification
經
辦
Prepared
Customer Certification
檢
查
Tested by
核
對
Checked
承 認
Approved
核 對
Checked by
承認簽印
Approved
承
認
Approved by
Add : Rm#502, Jen Ai Building No. 3, Wu-Chuan 1st Road, Wu-Ku Industrial Park,
New Taipei City 24892, Taiwan, R.O.C.
TEL : 886-2-22996808
FAX:886-2-22996807
www.gentlewayeer.com
SPECIFICATION FOR APPROVAL
REVISION
REV.
Descriptions
Before
A
Of
CONTROL
Change
After
Original SPEC
LIST
Changed
Date :
2012/03/16
ECN NO.
SPECIFICATION FOR APPROVAL
1. FEATURE :
 INPUT : UNIVERSAL 100-240 Vac/47-63 Hz INPUT, W ITHOUT ANY SLIDE SWITCH
 OUTPUT : +8.40V / 0-350mA
 DIMENSION : 62.0(D)*41.0(W)*23.5(H)
 EFFICIENCY : 62.0% TYPICAL
 SAFETY : LVD(STANDARD : EN60335-1/EN60335-2)
 EMI : EN55014 / EN61000 CLASS B; CONDUCTED & RADIATED MEETED
 INTELLIGENT CHARGING MANAGEMENT SYSTEM
 CHARGING : RED LED ; CHARGING FULL : BLUE LED ; FAULT : RED LED FLICKER
 CONSTANT CURRENT, CONSTANT VOLTAGE, FAULT BATTERY DETECTION
 OVER CHARGE PROTECTION, SHORT CIRCU ITED PROTECTION, REVERSE POLARITY PROTECTION
 APPLIES TO TWO CELL LITHIUM-ION BATTERY
2. INPUT :
2. 1
2. 2
2. 3
2. 4
2. 5
2. 6
VOLTAGE
FREQUENCY
CURRENT
INRUSH CURRENT
EFFICIENCY
INPUT POWER
DISSIPATION
UNIVERSAL 100~240Vac,SINGLE PHASE
47HZ~63HZ
0.2A Max
5A Max/100Vac;10A Max/240Vac (COLD STABT AT 25℃ FULL LOAD)
62.0% TYPICAL (AT NOMINAL LINE VOLTAGE FULL LOAD)
UNDER 1.5W < ZERO LOAD 115V/60HZ INPUT
UNDER 1.5W < ZERO LOAD 230V/50HZ INPUT
3. OUTPUT :
3. 1 DC OUTPUT
VOLTAGE
CONSTANT CURRENT
NO - LOAD VOLTAGE
RANGE
RIPPLE & NOISE
TOTAL POWER
+8.4V
330mA Min~350mA Typ.~380mA Max
8.30V Min~8.40V Typ.~8.45V Max
100mV Max
3.0W Max
NOTE : FOR RIPPLE & NOISE MEASUREMENT, USE A 20MHZ BAND WIDTH FREQUENCY OSCILLOSCOPF, AND
ADD A 0.1uF MULTILAYER CAP. AND A LOW ESR ELECTROLYTICCAP. (10uF) AT OUTPUT CONNECTOR
TERMINALS. (AT NOMINAL LINE VOLTAGE FULL LOAD)
4. PROTECTION :
4. 1 OVER VOLTAGE
PROTECTION
8.8V MAX. The charger shall be hiccupped when output voltage reaches to its over voltage
protection trigger point. the charger will issue a flashing red warning signal..
SPECIFICATION FOR APPROVAL
4. 2 SHORT CIRCUIT
The charger shall be hiccupped when operating any output in a short circuit
PROTECTION
condition.
4. 3 FAULT BATTERY
when the rechargeable battery failure can not be filled with electricity, the charger will
DETECTION
issue a flashing red warning signal.
4. 4 REVERSE POLARITY
When the battery is not in the correct direction to insert the charger, the charger will
PROTECTION
automatically cut off the connection and battery charging power to protect.
NOTE : WHEN PROTECTION CIRCUIT IS WORKING THE POWER SUPPLY WILL HICCUPPED, ONCE THE
ABNORMAL CONDITIONS ARE REMOVED. THE POWER SUPPLY WILL RESTART AUTOMATICALLY.
5. SAFETY AND EMI REQUIREMENT :
5.1
SAFETY REQUIREMENT
a. SAFETY : LVD(STANDARD : EN60335-1/EN60335-2)
b. DIELECTRIC STRENGTH :5mA Max. CUT OFF CURREN
(1):PRIMARY TO SECONDARY
3000Vac
FOR 1 MINUTE
(2):PRIMARY TO FRAME GROUND
3000Vac
FOR 1 MINUTE
c. INSULAION
RESISTANCE :
(1):PRIMARY TO SECONDARY
50 M OHMS min
FOR 500Vdc
(2):PRIMARY TO FRAME GROUND
50 M OHMS min
FOR 500Vdc
d. LEAKAGE
CURRENT :
(1) :
100VAC / 60HZ
< 0.25 mA
(2) :
240VAC / 50HZ
< 0.25 mA
SPECIFICATION FOR APPROVAL
5.2
EMI/EMS REQUIREMENT
a. EMI :
EN55014 / EN61000 CLASS B; CONDUCTED & RADIATED MEETED
b. Electron Static Discharge(ESD) :
Applicable Standard
IEC/EN 61000-4-2
CONDITION
Contact discharge performance is 4KV;
Air discharge performance is 8KV
SPECIFICATION
Normal operation shall be
continued
c. Lightning Surge :
Applicable Standard
CONDITION
IEC/EN 61000-4-5
+/- 1KV (Line to Line)
+/- 2KV (Line to Ground)
SPECIFICATION
Normal operation shall be
continued
d. Electric Fast Transients :
Applicable Standard
IEC/EN 61000-4-4
CONDITION
+/-1KV for Power Supply Line
SPECIFICATION
Normal operation shall be
continued
6. OPERATION & ENVIRONMENT PERFORMANCE:
6.1 TEMPERATURE RANGE
OPERATING
0℃ ~ +40℃
STORAGE
-20℃ ~+70℃
6.2 HUMIDITY RANGE (NON CONDENSING)
OPERATING
10% ~ 90% RH
STORAGE
5% ~ 95% RH
SPECIFICATION FOR APPROVAL
6.3 Product operating/storage test requirement
TEST ITEM
:
CONDITION
High Temperature
Storage TEST
70 degree C for 72H
SPECIFICATION
There is no malfunction and deformation to
be found after TEST.
40 degree C for There is no malfunction and deformation to
High Temperature
be found after TEST.
Operation TEST 16H
-20 degree C for
LowTemperature
Storage TEST 72H
There is no malfunction and deformation to
0 degree C for
Low Temperature
Operation TEST 16H
There is no malfunction and deformation to
be found after TEST.
be found after TEST.
Apply 2 cycle from 0
Termal Shock
degree C to +40 degree C There is no malfunction and deformation
Operation TEST
to be found after TEST.
as 24 Hours as 1 cycle
Termal Shock
Storage TEST
6.4 COOLING :
Apply 2 cycle from -20
degree C to +70 degree C There is no malfunction and deformation
to be found after TEST.
as 2 Hours as 1 cycle
SHOULD OPERATE WITHOUT FAN
6.5 M.T.B.F. : 30000 HOURS Min ; 25℃ SEE CONDITION
SPECIFICATION FOR APPROVAL
7.
MECHANICAL REQUIREMENT :
7. 1 DIMENSION
: 62.0(D)*41.0(W)*23.5(H)
7. 2 DROP TEST : From a height of 100cm onto concrete or similar material.
No impairment of normal function, breaking away of any parts or change
7. 3 VIBRATION TEST : Non-operating but with packing. Shock acceleration 50 G, sin, 100Ms.
Directions of force : X , Y , Z . One time at 6 directions. There is no malfunction
and deformation to be found after TEST.
7. 4
APPEARANCE : There shall not be any remarkable defects such as clack, distortion, uneven color,
dirty nameplate and its peeling
SPECIFICATION FOR APPROVAL
( I ). LINE REGULATION TEST
Test result:
Test condition
Spec.
Reading1
90Vac / 0% load
8.30~8.45V
8.41V
115Vac / 0% load
8.30~8.45V
8.41V
132Vac / 0% load
8.30~8.45V
8.41V
180Vac / 0% load
8.30~8.45V
8.41V
230Vac / 0% load
8.30~8.45V
8.41V
264Vac / 0% load
8.30~8.45V
8.41V
Test condition
Spec.
Reading1
115Vac / 100% load
62.0% Typical
67.1%
230Vac / 100% load
62.0% Typical
62.1%
Reading2
Reading3
Reading2
Reading3
Reading2
Reading3
Reading2
Reading3
(II). EFFICENCY TEST
Test result:
(III). CURRENT REGULATION TEST
Test result:
Test condition
Spec.
Reading1
115Vac / CV7.5V
330~380mA
365mA
115Vac / CV7.5V
330~380mA
365mA
115Vac / CV7.5V
330~380mA
365mA
230Vac / CV7.5V
330~380mA
365mA
230Vac / CV7.5
330~380mA
365mA
230Vac / CV7.5V
330~380mA
365mA
(IV).RIPPLE & NOISE TEST
Test result:
Test condition
Spec.
Reading1
115Vac / 350mA load
100mV Max
90mV
230Vac / 350mA load
100mV Max
80mV
SPECIFICATION FOR APPROVAL
(VI). OVER VOLTAGE PROTECTION
Test result:
Test condition
Spec.
Reading1
115Vac / 0% load
Vout*(8.8V MAX)
8.65V
230Vac / 0% load
Vout*(8.8V MAX)
8.68V
Test condition
Spec.
Reading1
115Vac / 100% load
50mS Max
31mS
230Vac / 100% load
50mS Max
18mS
Reading2
Readimg3
Reading2
Reading3
Reading2
Readimg3
Reading2
Readimg3
(VII). RISE TIME
Test result:
(VIII). CHARGING TIME TEST
Test result:
Test condition
Spec.
Reading1
115Vac / CUSTOMER
3H +/- 15MIN
OK
3H +/- 15MIN
OK
BATTERY SAMPLE
230Vac / CUSTOMER
BATTERY SAMPLE
(IX). SHORT CIRCUIT PROTECTION
Test result:
Test condition
Spec.
Reading1
115Vac / 100% load
Under 1.5W
OK
230Vac / 100% load
Under 1.5W
OK
SPECIFICATION FOR APPROVAL
LABEL : (UNIT : mm)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF