奇恩電子股份有限公司 GENTLE WAYEER ELECTRIC CO., LTD. APPROVAL SHEET 客戶名稱 Customer 產品名稱 Description GN-009EN 客戶產品編號 Customer P/N 產品編號 P/N Gentle Wayeer Electric Co., Ltd. Certification 經 辦 Prepared Customer Certification 檢 查 Tested by 核 對 Checked 承 認 Approved 核 對 Checked by 承認簽印 Approved 承 認 Approved by Add : Rm#502, Jen Ai Building No. 3, Wu-Chuan 1st Road, Wu-Ku Industrial Park, New Taipei City 24892, Taiwan, R.O.C. TEL : 886-2-22996808 FAX:886-2-22996807 www.gentlewayeer.com SPECIFICATION FOR APPROVAL REVISION REV. Descriptions Before A Of CONTROL Change After Original SPEC LIST Changed Date : 2012/03/16 ECN NO. SPECIFICATION FOR APPROVAL 1. FEATURE : INPUT : UNIVERSAL 100-240 Vac/47-63 Hz INPUT, W ITHOUT ANY SLIDE SWITCH OUTPUT : +8.40V / 0-350mA DIMENSION : 62.0(D)*41.0(W)*23.5(H) EFFICIENCY : 62.0% TYPICAL SAFETY : LVD(STANDARD : EN60335-1/EN60335-2) EMI : EN55014 / EN61000 CLASS B; CONDUCTED & RADIATED MEETED INTELLIGENT CHARGING MANAGEMENT SYSTEM CHARGING : RED LED ; CHARGING FULL : BLUE LED ; FAULT : RED LED FLICKER CONSTANT CURRENT, CONSTANT VOLTAGE, FAULT BATTERY DETECTION OVER CHARGE PROTECTION, SHORT CIRCU ITED PROTECTION, REVERSE POLARITY PROTECTION APPLIES TO TWO CELL LITHIUM-ION BATTERY 2. INPUT : 2. 1 2. 2 2. 3 2. 4 2. 5 2. 6 VOLTAGE FREQUENCY CURRENT INRUSH CURRENT EFFICIENCY INPUT POWER DISSIPATION UNIVERSAL 100~240Vac,SINGLE PHASE 47HZ~63HZ 0.2A Max 5A Max/100Vac;10A Max/240Vac (COLD STABT AT 25℃ FULL LOAD) 62.0% TYPICAL (AT NOMINAL LINE VOLTAGE FULL LOAD) UNDER 1.5W < ZERO LOAD 115V/60HZ INPUT UNDER 1.5W < ZERO LOAD 230V/50HZ INPUT 3. OUTPUT : 3. 1 DC OUTPUT VOLTAGE CONSTANT CURRENT NO - LOAD VOLTAGE RANGE RIPPLE & NOISE TOTAL POWER +8.4V 330mA Min~350mA Typ.~380mA Max 8.30V Min~8.40V Typ.~8.45V Max 100mV Max 3.0W Max NOTE : FOR RIPPLE & NOISE MEASUREMENT, USE A 20MHZ BAND WIDTH FREQUENCY OSCILLOSCOPF, AND ADD A 0.1uF MULTILAYER CAP. AND A LOW ESR ELECTROLYTICCAP. (10uF) AT OUTPUT CONNECTOR TERMINALS. (AT NOMINAL LINE VOLTAGE FULL LOAD) 4. PROTECTION : 4. 1 OVER VOLTAGE PROTECTION 8.8V MAX. The charger shall be hiccupped when output voltage reaches to its over voltage protection trigger point. the charger will issue a flashing red warning signal.. SPECIFICATION FOR APPROVAL 4. 2 SHORT CIRCUIT The charger shall be hiccupped when operating any output in a short circuit PROTECTION condition. 4. 3 FAULT BATTERY when the rechargeable battery failure can not be filled with electricity, the charger will DETECTION issue a flashing red warning signal. 4. 4 REVERSE POLARITY When the battery is not in the correct direction to insert the charger, the charger will PROTECTION automatically cut off the connection and battery charging power to protect. NOTE : WHEN PROTECTION CIRCUIT IS WORKING THE POWER SUPPLY WILL HICCUPPED, ONCE THE ABNORMAL CONDITIONS ARE REMOVED. THE POWER SUPPLY WILL RESTART AUTOMATICALLY. 5. SAFETY AND EMI REQUIREMENT : 5.1 SAFETY REQUIREMENT a. SAFETY : LVD(STANDARD : EN60335-1/EN60335-2) b. DIELECTRIC STRENGTH :5mA Max. CUT OFF CURREN (1):PRIMARY TO SECONDARY 3000Vac FOR 1 MINUTE (2):PRIMARY TO FRAME GROUND 3000Vac FOR 1 MINUTE c. INSULAION RESISTANCE : (1):PRIMARY TO SECONDARY 50 M OHMS min FOR 500Vdc (2):PRIMARY TO FRAME GROUND 50 M OHMS min FOR 500Vdc d. LEAKAGE CURRENT : (1) : 100VAC / 60HZ < 0.25 mA (2) : 240VAC / 50HZ < 0.25 mA SPECIFICATION FOR APPROVAL 5.2 EMI/EMS REQUIREMENT a. EMI : EN55014 / EN61000 CLASS B; CONDUCTED & RADIATED MEETED b. Electron Static Discharge(ESD) : Applicable Standard IEC/EN 61000-4-2 CONDITION Contact discharge performance is 4KV; Air discharge performance is 8KV SPECIFICATION Normal operation shall be continued c. Lightning Surge : Applicable Standard CONDITION IEC/EN 61000-4-5 +/- 1KV (Line to Line) +/- 2KV (Line to Ground) SPECIFICATION Normal operation shall be continued d. Electric Fast Transients : Applicable Standard IEC/EN 61000-4-4 CONDITION +/-1KV for Power Supply Line SPECIFICATION Normal operation shall be continued 6. OPERATION & ENVIRONMENT PERFORMANCE: 6.1 TEMPERATURE RANGE OPERATING 0℃ ~ +40℃ STORAGE -20℃ ~+70℃ 6.2 HUMIDITY RANGE (NON CONDENSING) OPERATING 10% ~ 90% RH STORAGE 5% ~ 95% RH SPECIFICATION FOR APPROVAL 6.3 Product operating/storage test requirement TEST ITEM : CONDITION High Temperature Storage TEST 70 degree C for 72H SPECIFICATION There is no malfunction and deformation to be found after TEST. 40 degree C for There is no malfunction and deformation to High Temperature be found after TEST. Operation TEST 16H -20 degree C for LowTemperature Storage TEST 72H There is no malfunction and deformation to 0 degree C for Low Temperature Operation TEST 16H There is no malfunction and deformation to be found after TEST. be found after TEST. Apply 2 cycle from 0 Termal Shock degree C to +40 degree C There is no malfunction and deformation Operation TEST to be found after TEST. as 24 Hours as 1 cycle Termal Shock Storage TEST 6.4 COOLING : Apply 2 cycle from -20 degree C to +70 degree C There is no malfunction and deformation to be found after TEST. as 2 Hours as 1 cycle SHOULD OPERATE WITHOUT FAN 6.5 M.T.B.F. : 30000 HOURS Min ; 25℃ SEE CONDITION SPECIFICATION FOR APPROVAL 7. MECHANICAL REQUIREMENT : 7. 1 DIMENSION : 62.0(D)*41.0(W)*23.5(H) 7. 2 DROP TEST : From a height of 100cm onto concrete or similar material. No impairment of normal function, breaking away of any parts or change 7. 3 VIBRATION TEST : Non-operating but with packing. Shock acceleration 50 G, sin, 100Ms. Directions of force : X , Y , Z . One time at 6 directions. There is no malfunction and deformation to be found after TEST. 7. 4 APPEARANCE : There shall not be any remarkable defects such as clack, distortion, uneven color, dirty nameplate and its peeling SPECIFICATION FOR APPROVAL ( I ). LINE REGULATION TEST Test result: Test condition Spec. Reading1 90Vac / 0% load 8.30~8.45V 8.41V 115Vac / 0% load 8.30~8.45V 8.41V 132Vac / 0% load 8.30~8.45V 8.41V 180Vac / 0% load 8.30~8.45V 8.41V 230Vac / 0% load 8.30~8.45V 8.41V 264Vac / 0% load 8.30~8.45V 8.41V Test condition Spec. Reading1 115Vac / 100% load 62.0% Typical 67.1% 230Vac / 100% load 62.0% Typical 62.1% Reading2 Reading3 Reading2 Reading3 Reading2 Reading3 Reading2 Reading3 (II). EFFICENCY TEST Test result: (III). CURRENT REGULATION TEST Test result: Test condition Spec. Reading1 115Vac / CV7.5V 330~380mA 365mA 115Vac / CV7.5V 330~380mA 365mA 115Vac / CV7.5V 330~380mA 365mA 230Vac / CV7.5V 330~380mA 365mA 230Vac / CV7.5 330~380mA 365mA 230Vac / CV7.5V 330~380mA 365mA (IV).RIPPLE & NOISE TEST Test result: Test condition Spec. Reading1 115Vac / 350mA load 100mV Max 90mV 230Vac / 350mA load 100mV Max 80mV SPECIFICATION FOR APPROVAL (VI). OVER VOLTAGE PROTECTION Test result: Test condition Spec. Reading1 115Vac / 0% load Vout*(8.8V MAX) 8.65V 230Vac / 0% load Vout*(8.8V MAX) 8.68V Test condition Spec. Reading1 115Vac / 100% load 50mS Max 31mS 230Vac / 100% load 50mS Max 18mS Reading2 Readimg3 Reading2 Reading3 Reading2 Readimg3 Reading2 Readimg3 (VII). RISE TIME Test result: (VIII). CHARGING TIME TEST Test result: Test condition Spec. Reading1 115Vac / CUSTOMER 3H +/- 15MIN OK 3H +/- 15MIN OK BATTERY SAMPLE 230Vac / CUSTOMER BATTERY SAMPLE (IX). SHORT CIRCUIT PROTECTION Test result: Test condition Spec. Reading1 115Vac / 100% load Under 1.5W OK 230Vac / 100% load Under 1.5W OK SPECIFICATION FOR APPROVAL LABEL : (UNIT : mm)
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement