GE DNCD450GGWC 7.0 Cu. Ft. Super Capacity Gas Commercial Dryer Quick Specs


Add to my manuals
3 Pages

advertisement

GE DNCD450GGWC 7.0 Cu. Ft. Super Capacity Gas Commercial Dryer Quick Specs | Manualzz

25-1/2

27

42

51

36

Side View Rear View

DNCD450EG/GG

GE ® Super 7.0 Cu. Ft. Capacity Commercial Dryer

Dimensions and Installation Information (in inches)

Exhaust Options:

Electric: 4-way via rear, right, left and bottom. Maximum recommended exhaust duct length is 45 feet of 4" rigid ducting with two

90° elbows and a 4" dampered wall cap.

Gas: When viewed from the front of the unit, exhaust 3-way via rear, left and bottom. Maximum recommended exhaust duct length is 15 feet of 4" rigid ducting with two 90° elbows and a 4" dampered wall cap.

Circuit Requirements:

An individual, properly-grounded branch circuit, protected by a 30amp circuit breaker or a time-delay fuse, is required.

Electric Dryer Rating:

208/240V, 5600W, 24A, 60Hz

208V, 4400W, 22A, 60Hz

Note: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.

Installation Information: For complete information, see installation instructions packed with your dryer.

23-1/2 28-1/4

25-1/2*

Side View

*24-1/2" from the edge of the side panel to the front.

25-1/2" from front to edge of endcaps.

27

8-1/2

36

42

11-1/2

2-1/2

2

3-1/2

Rear View

Washer/Dryers SC QSart

For answers to your Monogram, ® GE Profile ™ or

GE ® appliance questions, visit our website at ge.com or call GE Answer Center ® service,

800.626.2000.

Listed by

Underwriters

Laboratories

Specification Revised 5/09 370408

DNCD450EG/GG

GE ® Super 7.0 Cu. Ft. Capacity Commercial Dryer

Dimensions and Installation Information (in inches)

For complete information, see installation instructions packed with your dryer.

Ducting Materials:

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct.

If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used

(Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used

ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition duct.

Please see installation instruction packed with your dryer for complete instructions when using flexible metal (foil type) ducting.

Exhaust Length Calculation:

1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.

2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Dryers must be exhausted to the outside.

Caution:

For personal safety do not terminate exhaust into a chimney, under any enclosed house floor

(crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.

Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.

Special Installation Requirements

Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the

dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side; 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes, with the

National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces

0" both sides; 3" rear

Dryer Exhausting Information – Use Metal Duct Only - Vertical and Horizontal Ducting

A

A

4

Domestic

B dryer models

2-1/2

7.0, 6.0 and 5.8 cu. ft.

capacity models all electric dryers

Number of

90° turns

0

1

2

3

4

Best performance

Maximum length of 4" dia. rigid metal duct

Exhaust hood type

A

4" opening

90 ft.

60 ft.

45 ft.

35 ft.

25 ft.

B

2-1/2" opening

60 ft.

45 ft.

35 ft.

25 ft.

15 ft.

For answers to your Monogram, ® GE Profile ™ or

GE ® appliance questions, visit our website at ge.com or call GE Answer Center ® service,

800.626.2000.

Listed by

Underwriters

Laboratories

Specification Revised 5/09 370408

DNCD450EG/GG

GE ® Super 7.0 Cu. Ft. Capacity Commercial Dryer

Features and Benefits

• Super 7.0 Cu. Ft. Capacity

• 5 Dry Cycles: Cottons (High Heat); Mixed Loads (High Heat); Permanent Press

(Medium Heat); Knits (Low Heat); Delicates (Extra Low Heat)

• 4 Temperatures

• Air Dry

• Digital Cycle Countdown

• Hush Quiet Package

• Lockable Lint Filter

• Reversible Door Swing

• DuraDrum

Interior

• Model DNCD450EGWC – White

• Model DNCD450GGWC – White

DNCD450EA/GA.EPS

02-09-2001

CLOTHES CARE SELECTION

COTTONS

MIXED

LOADS

PERM

PRESS

KNITS

DELICATES

AIR DRY

DOOR OPEN

AUTOMATIC SETTINGS

COTTONS : HI

MIXED LOADS: H

GH HEAT

IGH HEAT

PERM PRESS : M

ED HEAT

KNITS : LO

W HEAT

DELICATES : E

XTRA LOW HEAT

AIR DRY : N

O HEAT

HEAT

SETTINGS

HIGH

MED

LOW

EXTRA

LOW

DRYING

COOLDOWN

STATUS

CLEAN LINT FILTER

R

E T

For answers to your Monogram, ® GE Profile ™ or

GE ® appliance questions, visit our website at ge.com or call GE Answer Center ® service,

800.626.2000.

Listed by

Underwriters

Laboratories

Specification Revised 5/09 370408

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement