Watts Premier | User manual | MODEL WP-1 LCV

Add to my manuals
14 Pages

advertisement

Watts Premier | User manual | MODEL WP-1 LCV | Manualzz

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MODEL

WP-1 LCV

WP-1 LCV Tested and certified by NSF International against NSF/ANSI

Standard 53 for the reduction of claims specified on the performance data sheet.

Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure and possible damage to property.

Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.

Watts Premier, Inc.

Phone: 800-752-5582

Manual #: 199362

8716 W Ludlow Drive Suite #1 Peoria, AZ 85381

www.wattspremier.com Fax: 623-866-5666

Manual Date: 05/18/2012

Thank you for your purchase of a state of the art

Watts Premier Water Treatment system.

WP-1 LCV Water Treatment System:

Watts Premier WP-1 LCV water treatment system contains a heavy duty lead, cyst and VOC filter block. This specialty formulated block is capable of reducing lead, cryptosporidium, Giardia, Entamoeba as well as harmful Volatile Organic Chemicals

(See performance data sheet for complete list of VOC’s). It is estimated that VOC’s are present in one-fifth of the nation’s water supplies. These water contaminants can enter ground water from a variety of sources including localized use of herbicides and pesticides, gasoline or oil spills, leaking underground fuel tanks, septic system cleaners, and chemicals used in the dry-cleaning industry. See performance data sheet for individual contaminants and reduction performance.

System Maintenance

Just because you can not taste it, does not mean that it is not there. Many contaminants in the drinking water are undetectable to the taste. Additionally, over time if you do not replace the filter element, other bad tastes and odors will be apparent in your drinking water. This is why it is important to change out your filter at the recommended intervals as indicated in this system manual. When replacing any of the filter elements, pay special attention to any cleaning instructions. Should you have any further questions please refer to our website at www.wattspremier.com or call our customer service dept. at 1-800-752-5582.

2

Table of Contents

Maintenance Record.....................................................................................................

3

Operational Parameters ...............................................................................................

4

Contents of WP-1 System .............................................................................................

Tools Recommended For Installation ...........................................................................

4

4

Under Sink Mounting.....................................................................................................

Drill a Hole for the Faucet in a Porcelain Sink................................................................

Punch a Hole for the Faucet in a Stainless Steel Sink..................................................

4

5

5

Installation of Faucet.....................................................................................................

6

Adapt-a-Valve Installation...............................................................................................

7

Start Up.........................................................................................................................

7

Filter Change.................................................................................................................

8

Parts Listing ..................................................................................................................

9

Performance Data Sheet ..............................................................................................

California Certificates .....................................................................................................

10-11

12

Removing Chlorine from your Shower...........................................................................

13

Warranty .......................................................................................................................

14

Maintenance Record

Date of Purchase:__________ Date of Install:_________ Installed by:____________

NOTES:

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

________________________________________________________________________

3

Operational Parameters

Installation needs to comply with state and local plumbing regulations. This system is intended to be installed on the cold supply line only.

Maximum

Operational Temperature 100°F (37.8°C)

Operating Pressure

Minimum

40°F (4.4°C)

100 psig (7.43 g/cm²) 20 psig (1.406 kg/cm²) pH Parameters

Flow Rate

10

0.5 GPM @ 60 psig

5

Contents of Under Counter System

1 WP-1 Unit

1 Filter

1 Parts Bag

If any of the items are missing, please contact Watts Premier prior to installing

Tools Recommended For Installation

√ A small knife

√ Variable Speed drill

√ 1/8” (3mm), 1/4” (6.4 mm) and 7/16” (11.0mm) Drill bits

√ 1/2” and 5/8” open-end wrenches (or adjustable Wrenches)

√ Phillips screwdriver

Installation

This system has been designed to fit under most kitchen sinks. Please read carefully before proceeding with installation.

Step 1: Mounting System Under Sink

(a) Locate a space under the sink that allows the unit to be mounted close to the cold water supply and allows for easy access during maintenance and filter changes.

System must be installed to the cold water supply only. Allow approximately 2” (5cm) clearance between the bottom of the filter housing and the floor of the sink cabinet.

(c) Using the mounting hole on the bracket, mark the location for the mounting screws on the cabinet wall under the sink.

(d) Screw the (2) screws into the wall at the marked location.

(e) Hang the module on the screws using the mounting holes in the bracket.

4

Drill a Hole for the Faucet in a Porcelain Sink

Note: Most sinks are pre drilled with 1 ½” or 1 ¼” diameter hole that you can use for your faucet. (If you are already using it for a sprayer or soap dispenser, see step 1)

Step 1

Porcelain sinks are extremely hard and can crack or chip easily.

Use extreme caution when drilling. Watts Premier accepts no responsibility for damage resulting from the installation of faucet.

Diamond tip drill bit is recommended for drilling in porcelain.

Determine desired location for the faucet on your sink and place a piece of masking tape over where the hole is to be drilled. Mark the center of the hole on the tape.

Step 2 Using a variable speed drill set on the slowest speed, drill a

1

/

8

“ pilot hole through both porcelain and metal casing of sink at the marked center of the desired location. Use lubricating oil or liquid soap to keep the drill bit cool (If drill bit gets hot it may cause the porcelain to crack or chip).

Step 3 Using a 1/2” Drill Bit, proceed to drill the larger hole. Keep drill speed on the slowest speed and use lubricating oil or liquid soap to keep the hole saw cool during cutting.

Step 4

Make sure the surroundings of the sink are cooled before mounting the faucet to the sink after drilling and remove all sharp edges.

Punch a Hole for the Faucet in a Stainless Steel Sink

Note: If mounting faucet to a Stainless Steel Sink you will need a 1/2”

Hole Punch. The faucet opening should be centered between the back splash and the edge of the sink, ideally on the same side as the vertical drain pipe.

Step 5

Drill a ¼ ” pilot hole. Use a

1

/

2

” Hole Punch and an adjustable wrench to punch the hole in the sink.

The faucet can now be installed.

5

Installation of Faucet

Step 1

Place the escutcheon chrome plate and the black rubber washer on the faucet shank. (Parts found in faucet parts bag).

Step 2 Insert the faucet shank through the hole in sink and let it rest on the sink top.

Step 3

From the underside of the sink, slide on the locating washer, lock washer and brass nut onto the shank. Check orientation of faucet then tighten brass nut

securely.

Step 4 Connect blue tube from the filtration system to the faucet shank.

Place the brass nut onto the tube, followed by the plastic sleeve (tapered end pointing to the end of tube) and then place the plastic insert into the end of the tube.

Step 5 Insert the assembled blue tube into the end of the faucet shank and use a wrench to tighten the brass nut securely.

6

Adapt-a-Valve Installation

Caution: Water supply line to the system must be from the cold water supply line.

Hot water will severely damage your system.

(A) Turn off the main supply water to the house.

(B) Turn off the cold water supply to the faucet by turning the angle stop valve clockwise until it is completely off. Drain any water in the line by opening the faucet cold side.

(C) Attach adapt-a-valve as illustrated in the center photo below, choosing the configuration that fits your plumbing.

(D) Attach the loose end of the green tube to the Adapt-a-Valve.

Insert the green tube into the ¼” opening on the adapt-a-valve until it stops.

(E) Turn on water supply and open the Adapt-a-valve. Check for leaks.

Configuration:

* Washer

Configuration for 3/8”

(With Brass Fittings)

* Insert White Washer

Hot

Supply

Cold

Supply

Configuration for 1/2”

(Without Brass Fittings)

System Start Up

(A) Turn faucet handle to the open position to start the flow of water through the unit. Run 7 gallons of water through the unit in order to flush out the normal black carbon fines (it will

“sputter” until the air is purged out) from the unit. Initially, the water may appear cloudy which is due to tiny air bubbles and it will clear up shortly. Close the faucet when finished.

(B) Check for leaks. If you have any leaks, shut off the water supply to your system, tighten any fittings / housings and restart unit.

7

FILTER CHANGE

Watts Premier recommends changing the filter element every 6 months.

Use Watts Premier’s replacement cartridge only. Other filters may look the same, but only filters by Watts are manfactured to fit your WP-1 filter unit in order to ensure proper reduction of water contaminants.

Carbon Block Filter

WP-1 LCV Part# 101014

(a) Turn off incoming water supply to the WP-1 at the adapta-valve. Note: There will be water in the filter housing.

Lift the faucet handle to relieve the water pressure.

(b) Remove filter housing from lid by turning it to the left, as shown in Figure D.

(c) Remove used filter cartridge and discard.

NOTE: Do not discard filter-housing o-ring.

(d) Clean inside of filter housing with warm soapy water and rinse to remove soap

(e) Lubricate o-ring with water-soluble lubricant (i.e. K-Y Jelly

® or Silicone lubricant).

NOTE: Do not use Petroleum based lubricants such as

Vaseline ®.

(f) Seat o-ring in groove in filter housing and insert new filter cartridges into filter housing.

(g) Screw filter housing onto lid as shown in Figure D.

(h) Turn on water supply to filter unit at the Adapt-a-Valve.

(i) Check system for leaks.

Figure D

To Loosen To Tighten

8

5

7

8

9

10

6

2

4

6

ITEM

QTY

PART # DESCRIPTION

1 1 101014

Lead, Cyst. VOC Carbon Block

2 1

3

4

5

6

7

8

9

1

1

1

1

1

1

1

113002 Lid

113019

Housing 10” Blue

113054

O-Ring

116023

Faucet - NON-AG

122036

Flow Control Elbow

560080

Adapt-a-Valve

140004

Tubing-1/4” Blue 4FT

140007

Tubing-1/4” Green 4FT

3

9

Performance Data Sheet

Watts Premier Inc.

8716 W Ludlow Drive Suite #1

Peoria, AZ 85381

WP-1 LCV

GENERAL USE CONDITIONS:

1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

2: Operating Temperature:

3: Operating Water Pressure:

4: Maximum flow Rate:

5: Rated Capacity:

Maximum

Maximum

100 o

C)

100-psi (7.43 kg/cm

0.50 gpm (1.89 lpm) o

F (40.5

600 Gallons (2,200 liters)

2

)

RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:

Minimum 40

Minimum 20-psi

Note: Depending on incoming feed water conditions replacement time frame may vary.

Description

Stage 1: Carbonblock

Part Number

101014

Change time Frame

o

F (4.4

6 Months or 600 gallons of water

o

C)

Cost

$28.95

This system has been tested according to NSF/ANSI Standard 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissable limit for water leaving the system, as specified in NSF/ANSI 53. Testing performed under standard laboratory conditions, actual performance may vary.

California Proposition 65 Warning

WARNING: this product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

(Installer: California law requires that this warning be given to the consumer). For more information: www.wattsind.com/prop65.

Substance

ALACHLOR*

ATRAZINE*

BENZENE*

BROMODICHLOROMETHANE (TTHM)*

BROMOFORM (TTHM)*

CARBOFURAN (Furadan)*

CARBON TETRACHLORIDE*

CHLORDANE

CHLOROBENZENE (Monochlorobenzene)*

CHLOROFORM (TTHM)*

CRYPTOSPORIDIUM (see Cyst)

CYST

2, 4-D*

DBCP (see Dibromochloropropane)*

1,2-DCA (see 1,2-DICHLOROETHANE)*

1,1-DCE (see 1,1-DICHLOROETHYLENE)*

DIBROMOCHLOROMETHANE

(TTHM;Chlorodibromomethane)*

DIBROMOCHLOROPROPANE (DBCP)* o-DICHLOROBENZENE (1,2 Dichlorobenzene)* p-DICHLOROBENZENE (para-Dichlorobenzene)*

1,2-DICHLOROETHANE (1,2-DCA)*

1,1-DICHLOROETHYLENE (1,1-DCE)*

CIS-1,2-DICHLOROETHYLENE*

TRANS-1,2- DICHLOROETHYLENE*

1,2-DICHLOROPROPANE (Propylene Dichloride)*

CIS-1,3- DICHLOROPROPYLENE*

DINOSEB*

EDB (see ETHYLENE DIBROMIDE)*

ENDRIN*

Percent

Reduction

>98%

>97%

>99%

>99.8%

>99.8%

>99%

98%

>99%

>99.8%

99.99%

99.99%

98%

>99%

95%

>99%

>99.8%

>99%

>99%

>98%

95%

>99%

>99%

>99%

>99%

>99%

99%

>99%

99%

Influent Challenge

Concentration

(mg/L unless noted)

0.04 +/- 0.10

0.009 +/- 0.10

0.015 +/- 0.10

0.300 +/- 0.30

0.300 +/- 0.30

0.08 +/- 0.10

0.015 +/- 0.10

0.04 +/- 0.10

2.0 +/- 0.10

0.300 +/- 0.30

minimum 50,000/mL minimum 50,000/mL

0.210 +/- 0.10

0.052

0.088

0.083

0.300 +/- 0.30

0.004 +/- 0.10

1.8 +/- 0.10

0.225 +/- 0.10

0.015 +/- 0.10

0.021 +/- 0.10

1.4 +/- 0.10

2.0 +/- 0.10

0.015 +/- 0.10

0.079

0.021 +/- 0.10

0.044

0.006 +/- 0.10

Maximum Permissible

Product Water

Concentration

0.002

0.003

0.005

0.015

0.015

0.04

0.005

0.002

0.1

0.015

99.95%

99.95%

0.07

0.00002

0.0048

0.001

0.015

0.0002

0.6

0.075

0.005

.007

0.07

0.1

0.005

0.001

0.007

0.00002

0.002

10

Substance

ENTAMOEBA

ETHYLBENZENE*

ETHYLENE DIBROMIDE (EDB)*

FURADAN (see CARBOFURAN)*

HALOACETONITRILES (HAN)*

BROMOCHLOROACETONITRILE

DIBROMOACETONITRILE

DICHLOROACETONITRILE

TRICHLOROACETONITRILE

HALOKETONES (HK):*

1,1-DICHLORO-2-PROPANONE

1,1,1-TRICHLORO-2-PROPANONE

GIARDIA LAMBLIA (see Cyst)

HEPTACHLOR*

HEPTACHLOR EPOXIDE*

HEXACHLOROBUTADIENE

(Perchlorobutadiene)*

HEXACHLOROCYCLOPENTADIENE*

LEAD pH 6.5

LEAD pH 8.5

HEPTACHLOR (H-34, HEPTOX)

HEPTACHLOR EPOXIDE

HEXACHLOROCYCLOPENTADI

LINDANE*

METHOXYCHLOR*

METHYLBENZENE (see TOLUENE)*

MONOCHLOROBENZENE

(see CHLOROBENZENE)*

PCE (see TETRACHLOROETHYLENE)*

PENTACHLOROPHENOL*

PERCHLOROBUTADIENE

(see HEXACHLOROBUTADIENE)*

PROPYLENE DICHLORIDE

(see 1,2 -DICHLOROPROPANE)*

POLYCHLORINATED BIPHENYLS (PCBs, Aroclor 1260)

SIMAZINE*

SILVEX (see 2,4,5-TP)*

STYRENE (Vinylbenzene)*

1,1,1-TCA

(see 1,1,1 - TRICHLOROETHANE)*

TCE (see TRICHLOROETHYLENE)*

1,1,2,2- TETRACHLOROETHANE*

TETRACHLOROETHYLENE*

TOLUENE (Methylbenzene)*

TOXOPLASMA

2,4,5-TP (Silvex)*

TRIBROMOACETIC ACID*

TOXAPHENE

1,2,4 TRICHLOROBENZENE (Unsymtrichlorobenzene)*

1,1,1-TRICHLOROETHANE (1,1,1-TCA)*

1,1,2-TRICHLOROETHANE*

TRICHLOROETHYLENE (TCE)*

TRIHALOMETHANES (TTHM) (Chloroform; Bromoform;

Bromodichloromethane; Dibromochloromethane)

Unsym-Trichlorobenzene (see 1,2,4-

TRICHLOROBENZENE)*

Vinylbenzene (see STYRENE)*

XYLENES

>99%

95%

>99%

>99%

>99.8%

>99%

>99%

11

>99%

>99%

>99%

>99%

>99%

>99%

>99%

>98%

>99%

>97%

99%

>99%

95%

>99%

>99%

>99%

>99%

99%

Percent

Reduction

99.99%

>99%

>99%

>99%

Influent Challenge

Concentration

(mg/L unless noted)

minimum 50,000/mL

2.1 +/- 0.10

0.001 +/- 0.10

0.19

Maximum Permissible

Product Water

Concentration

99.95%

0.7

0.00005

0.001

98%

98%

98%

98%

99%

96%

99.99%

>99%

98%

>98%

>99%

99%

99%

0.022

0.024

0.0096

0.015

0.01 +/- 0.10

0.012 +/- 0.10

0.270

2.0 +/- 0.10

0.084

0.180

0.081

0.015 +/- 0.10

3.0 +/- 0.10

minimum 50,000/mL

0.15 +/- 0.10

0.042

0.015 +/- 0.10

0.21 +/- 0.10

0.6 +/- 0.10

0.015 +/- 0.10

0.300 +/- 0.10

0.45 +/- 0.20

0.160

0.150

30 +/- 0.10

0.0072

0.0082

minimum 50,000/mL

0.25

0.0107

0.044

0.060

0.15 +/- 10%

0.15 +/- 10%

0.08 +/- 0.10

0.004 +/- 0.10

0.15 +/- 0.10

0.002 +/- 0.10

0.12 +/- 0.10

0.015 +/- 0.20

0.077

0.081

0.01 +/- 0.10

0.044

0.080

0.0005

0.0006

0.0002

0.0003

0.0005

0.004

0.0016

0.1

0.0046

0.0010

0.001

0.005

1

99.95%

0.05

0.001

0.003

0.07

0.2

0.005

0.005

0.080

0.0005

0.0005

10

0.0001

0.0003

99.95%

0.00001

0.0002

0.001

0.000002

0.010

0.010

0.0004

0.0002

0.05

0.0002

0.04

0.005

0.001

0.001

0.001

0.001

0.001

Removing chlorine from your shower

Special Chlorgon & KDF media – More effective then carbon medias with hot water applications in the removal of the following.

√ Free Chlorine (CL-)

√ Combined Chlorine (Sodium Hypochlorite)

√ Hydrogen Sulfide (Rotten egg smell)

√ Plus, its pH balanced.

√ Iron oxide (rust water)

√ Dirt, sediment

√ Odors

Deluxe Shower Handle with Built in Filter

Replacement filters 2PK

5-Way Massaging Spray

72” Reinforced Hose

High Strength Bracket

Triple Plated Finish

Reversible Filter Cartridge (Model HHC)

Cartridge Life Rating: 3 months

Part No. 107070 WHITE

Part No. 107091 CHROME

Part No. 107092 GOLD

*$38.95

*$44.95

*$44.95

Part No. 107075 *$15.95/pk

Shower Falls Deluxe Shower Handle with Built in Filter

Curved Ergonomic Shower Handle

Replacement filters 2PK

Dual Swivel Adjustment

Ultra Deluxe 5 Way Massaging Spray

72” Reinforced Hose

Chrome Plated Brass Bracket & Swivel Ball Extension

Triple Plated Finish

Reversible Filter Cartridge (Model HHC)

Cartridge Life Rating: 3 months

Part No. 107095 CHROME *$55.95

All-In-One reversible High-Flow Filter

Deluxe 5-Way Massaging Spray

Soft-Touch Adjustment Pads

Anti-Scaling Spray Nozzle

High Strength Housing

Triple Plated Finish

Cartridge Life Rating: 6 months

Part No. 107098 White/Chrome

Replacement filter

*$39.95 Part No. 107080 *$13.95/ea

*All prices subject to change without notice.

12

8716 W Ludlow Drive Suite #1

Peoria, AZ 85381

Limited Warranty

What your Warranty Covers:

If any part of your WATTS PREMIER WP-1 is defective in workmanship (excluding replaceable filters ), return unit after obtaining a return authorization (see below), within 3 year of original retail purchase, WATTS PREMIER will repair or, at

WATTS PREMIER’S option, replace the system at no charge.

How to obtain Warranty Service:

For warranty service, call 1-800-752-5582 for a return authorization number. Then, ship your unit to our factory, freight and insurance prepaid, with proof of date of original purchase. Please include a note stating the problem. Premier will repair it, or replace it, and ship it back to you prepaid.

What this warranty does not cover:

This warranty does not cover defects resulting from improper installation, (contrary to WATTS PREMIER’S printed instructions), from abuse, misuse, misapplication, improper maintenance, neglect, alteration, accidents, casualties, fire, flood, freezing, environmental factors, water pressure spikes or other such acts of God.

This warranty will be void if defects occur due to failure to observe the following conditions:

1. The WP-1 System must be hooked up to a potable municipal or well cold water supply.

2. The pH of the water must not be lower than 5 or higher than 10.

3. The incoming water pressure must be between 20 and 100 pounds per square inch.

4. Incoming water to the Counter Top cannot exceed 100 degrees F (38 degrees C.)

This warranty does not cover any equipment that is relocated from the site of its original installation.

This warranty does not cover any equipment that is installed or used outside the United States of America and Canada.

LIMITATIONS AND EXCLUSIONS:

WATTS PREMIER WILL NOT BE RESPONSIBLE FOR ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTIBILITY

AND FITNESS FOR A PARTICULAR PURPOSE. WATTS PREMIER WILL NOT BE RESPONSIBLE FOR ANY INCIDENTAL OR

CONSEQUENTIAL DAMAGES, INCLUDING TRAVEL EXPENSE, TELEPHONE CHARGES, LOSS OF REVENUE, LOSS OF TIME,

INCONVENIENCE, LOSS OF USE OF THE EQUIPMENT, AND DAMAGE CAUSED BY THIS EQUIPMENT AND ITS FAILURE TO

FUNCTION PROPERLY. THIS WARRANTY SETS FORTH ALL OF PREMIER’S RESPONSIBILITIES REGARDING THIS EQUIPMENT.

OTHER CONDITIONS:

If WATTS PREMIER chooses to replace the equipment, WATTS PREMIER may replace it with reconditioned equipment. Parts used in repairing or replacing the equipment will be warranted for 90 days from the date the equipment is returned to you or for the remainder of the original warranty period, whichever is longer. This warranty is not assignable or transferable.

YOUR RIGHTS UNDER STATE LAW:

Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply. This warranty gives you specific legal rights, and you may have other legal rights which vary from state to state.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement