Contents
Indoor Air Quality ................................................. 4
Analyzers & Monitors........................................... 5
Leak Detection ..................................................... 6
Refrigeration Recovery Units ................................ 12
Vacuum Pump / Swaging Kit / Charging Scale ..... 14
Digital Multimeter (DMM) .................................... 15
Manifolds and Hoses ............................................ 16
Gauges ................................................................ 18
Service Tools ........................................................ 19
Service Tools and Meters...................................... 20
RSP-PRC036-EN
3
Indoor Air Quality
Sling Psychrometer
The uniquely compact Bacharach® Sling
Psychrometer accurately determines
percent relative humidity without the
necessity of consulting complex tables.
There is no need to wet the wick each
time a reading is taken; the Sling
Psychrometer contains a slide rule
calculator which correlates wet and dry
bulb thermometer indications for direct
reading of relative humidity. When not in
use, the thermometer case telescopes
into the handle for protection.
Dual-Channel Digital
Thermometer
Model TH3000
Features
• Temperature: -50°F ~ 1999°F
(-50°C ~ 1300°C)
• 2 K-Type 39” Thermocouples
• T1-T2 differential measurement
• Resolution:1°F / 1°C
• Data-hold and max-hold functions
• Flip-up stand
• Includes protective boot and battery
Humidity-Temperature Meter
Model TH1800
Features
• Humidity: 10% RH ~ 95% RH
• Temperature: -4°F ~ 140°F
(-20°C ~ 60°C)
• Resolution: 0.1°C / 0.1°F / 0.1%RH
• Wet bulb and dew point temp. readings
• Data-hold and relative function
• Dual LCD display with bargraph indication
• Includes soft carrying case and batteries
Features
• Designed for portability
(7.5” long x 1” diameter)
• Slide rule construction quickly converts
temperature to relative humidity
• Built-in water reservoir holds sufficient
water for several hours of testing
• Thin bulb design gives fast thermal
response
• Thermometers constructed of shock
resistant glass; stems have deep-etched
numerals and 1° scale divisions for
easy reading
• Accurate to within ±5% R.H.
Ordering Information
ServiceFirst
Item #
MTR00971
TOL02776
MTR00972
KIT12491
CAP01006
TOL02777
MTR00980
4
Mfg. #
12-7011
12-7012
12-0267
12-0011
06-5456
2030-0000
2002-1800
Description
+20°F to +120°F Mercury Filled Sling Psychrometer
+20°F to +120°F Red Spirit Filled Sling Psychrometer
Thermometer (+25°F + 120°F Mercury Filled)
Sling Psychrometer Wick Replacement Kit - contains 4 wicks
Sling Psychrometer Cap
Dual-Channel Digital Thermometer
Humidity-Temperature Meter
RSP-PRC035-EN
Analyzers & Monitors
Carbon Monoxide Analyzer
Bacharach’s Monoxor® III offers service
technicians the easiest and most
affordable way to locate CO in ambient
air as well as stack gases. The
Monoxor® III CO Analyzer is a battery
powered, hand-held instrument that can
quickly and accurately measure levels of
CO between 0 and 2,000 ppm. In
addition to locating CO in ambient air,
the Monoxor® III is supplied with a
stainless steel probe and five feet of
tubing to sample CO found in flue gases
of residential furnaces, combustion
appliances, commercial and industrial
boilers. An optional wireless IrDA printer
provides a permanent record of the
detected CO level.
Specifications
Range
Resolution
Accuracy
Operating Temp.:
Battery Life
Display
Power
Printer Port
Weight
Dimensions
Warranty
0-2,000 ppm
1 ppm
+_ 5% of reading or 10 ppm, whichever is greater
Instrument: 32-104°F (0-40°C)
Probe: 1,000OF (538°C)
24 hours continuous (minimum of 16 hours)
Four-digit LCD display w/backlight
4 ‘AA’ Alkaline batteries
IrDA or HP protocol
16 oz. with batteries
7.5”H x 3.1”W x 2.1”D (190mm x 79mm x 53mm)
2 years, including sensor
Ordering Information
RSP-PRC035-EN
ServiceFirst
Item #
TOL02693
Mfg. #
19-8104
TOL02794
PAP00004
PAP00005
SEN01324
ADP01128
FLR06385
24-1400
06-8733
24-1310
24-7265
24-1254
07-1644
Description
Monoxor® III includes 4 ‘AA’ batteries, probe & hose assembly
with integral water-trap / filter, and a hard carrying case.
IrDA Printer with Disposable Batteries
Printer paper, 1 roll package
Printer paper, 5 roll package
Replacement CO sensor
Battery eliminator
Filter Element for Water Trap, Package of 3
5
Leak Detection
Leakator® Jr.
Leakator® Jr is a handheld combustible
gas leak detector used to pinpoint
combustible gas leaks in commercial,
residential and industrial applications,
including surveying gas pipelines and
inspecting valves, regulators and meters
on gas equipment. When combustible
gases are sensed, audible and visual
indication will be given. Combustible
gases detected include: Acetone,
Acetylene, Benzene, Butane, Ethanol,
Ethylene Oxide, Gasoline, Hexane,
Hydrogen, Industrial Solvents, IsoButane, Methane, Methanol, Paint
Thinners, Propane, Natural Gas and
Naptha.
Features
• Visual Indicator
1 LED (Variable Frequency)
• Audible Indicator
Loud audible ticking rate
• 2 Sensitivity Levels
Aids in pinpointing leak detection
• Operational Status LED
• Low Power Metal Oxide Sensor
Plug-in sensor
• 12 Inch Flexible Probe
• Tough ABS Plastic Housing
Durable and rugged
• UL Classified
• Automatic Calibration
• Micro Processor Controlled Circuitry
• Easily Replaced AA-Batteries
Battery life is 14 hours
• New Compact Design
Fits in the palm of hand
(6”L x 2”W x 1.5”D)
• 2 Year Warranty
Specifications
Housing
Power
Warm-up Time
Sensor
Probe
Sensitivity
(Methane Based)
Status Indicators
Environments
Dimensions /
Weight
Safety Approvals
Warranty
Molded four piece ABS plastic
Four alkaline AA-batteries, included. Battery life is 14 hours
Automatic calibration, about 60 seconds to operational condition
Low power metal oxide
Self storing 12 inch flexible probe. Accommodates integral sensor
20 ppm in high sensitivity mode
50 ppm in low sensitivity mode
Visual: 1 ultra-bright variable frequency LED.
Audible: Variable speed ticking sound.
Power-On flashing green, Power-Off solid red,
Ready Condition Flashing green (low frequency)
32° to 104°F (0° to 40°C) 15% to 75%, non-condensing
6”H x 2”W x 1.5”D (15.3 cm x 5 cm x 3.8 cm)
6 oz. (0.17Kg.)
UL 913, intrinstically safe, for use in Class I, Division I,
Groups A,B,C, and D hazardous locations
Two year full warranty on instrument
Ordering Information
6
ServiceFirst
Item #
TOL02784
Mfg. #
19-7075
SEN01374
19-0575
Description
Leakator® Jr., flexible 12 inch probe for combustible gases and
vapors, with instruction manual, sensor, cloth case, and batteries.
Replacement sensor
RSP-PRC035-EN
Leak Detection
Leakator® 10
Bacharach’s Leakator® 10 is a low
maintenance combustible gas leak
detection unit, small enough to be
operated with just one hand, yet loaded
with the kind of advanced features and
technology professionals demand.
Powered for up to 30 hours of
continuous operation by alkaline C-cell
batteries, Leakator® 10 comes complete
with a flexible 20-inch long probe for
hard-to-reach areas and a solid state
sensor that will last for up to five years.
Leakator® 10 allows you to pinpoint
large and small leaks quickly, while
checking a relatively large area in a short
amount of time.
Features and Benefits
• Visual Indicator
10 Ultra-bright LEDs
• Audible Indicator
Loud audible ticking rate
• 30 Hour Battery Life
Easily replaced C-cells
• Sensitivity Thumb-Wheel
Aids pinpointing leak detection
• Operational Status LEDs
English and international systems
• Solid State Sensor
Plug-in sensor, five year typical life
• 20 Inch Flexible Probe
For hard to reach locations
• Also Available for ETO
Part No. 19-7063
• UL Listed
Intrinsically safe
• CE Mark
Electronic performance standard
Specifications
Housing
Power
Warm-up Time
Sensor
Probe
Sensitivity
Status Indicators
Environments
Dimensions /
Weight
Safety Approvals
Warranty
Molded, three piece ABS plastic in bright yellow color, includes carrying strap
Five alkaline C-cells, not provided
30 hours typical life for continuous operation
Automatic, self check, about ten seconds to operational condition
Semiconductor type. Five year typical life.
Plug-in replacement
Self storing 20 inch flexible probe. Accommodates integral sensor
20 ppm useable sensitivity (methane)
Visual: 10 ultra-bright red LED’s. Audible: Variable speed ticking sound. Earphone
available for use in noisy environments. Power-On ultra-bright green LED, Fail
ultra-bright yellow LED. Low Battery ultra-bright yellow LED
23° to 130° F (-5°to 54°C), 10% to 90% relative humidity, non condensing
Leakator®: 18 oz. (0.51Kg.), 8.5” x 2.25” x 1.75”
(21.6 cm x 5.7 cm x 4.4 cm)
Case: Black HDPE, 17 oz. (.48Kg), 10.5” x 7” x 3”
(26.7 cm x 17.8 cm x 7.6 cm)
UL listed, intrinsically safe, for use in Class l, Division 1,
Groups A, B, C, and D classified areas
One year limited warranty. See warranty card for more information
Ordering Information
ServiceFirst
Item #
TOL02705
RSP-PRC035-EN
Mfg. #
19-7051
Description
Leakator® 10, in custom carrying case, flexible 20 inch probe for
combustible gases and vapors, with instruction manual (batteries
not included)
7
Leak Detection
Tru Pointe®
Refrigerant Leak Detector
Bacharach’s newest refrigerant leak
detector, the Tru Pointe®, is designed
specifically for technicians looking for a
premium quality leak detector at an
affordable price.
The Tru Pointe® is designed to be
instantly responsive to all refrigerants.
It is even accurate when used in
environments where high levels of
refrigerant vapors are present. No
manual sensitivity adjustments are
necessary during the inspection process.
Simply turn the unit on, and let it mark
the spot!
Features
• Detects all CFC, HFC, and HCFC
refrigerants using patented heated
diode sensor technology
• Instantaneous response time
• Innovative sensor replacement design
• Up to 20 hours continuous operation
on 2 ‘D’ alkaline batteries
• Battery-powered with low battery
indication
• Long-life, DC brushless fan
• High and low-sensitivity modes
• Automatic zero and background
compensation
• Audible & visual leak indication
• Easy to use, one-handed operation
• No user calibration required
Specifications
Sensing Elements
Type:
Patented Heated Diode, Plug-in
Life Expectancy:
150 Hours or 1 year of normal use
Refrigerants Detected All CFC, HCFC and HFC refrigerants, including R-12, R-22, R-123, R-134a and blends
R-404a, R-408A, R-409A, and R-410A (i.e. any refrigerant containing Chlorine,
Fluorine or Bromine gas)
Alarm Sensitivity
0.5 oz / year (14g/year) per SAE J1627
of R-134a (Hardest
0.1 oz / year (3g/year) when probe is held over leak source for at least 5 seconds
refrigeration to detect)
Alarm Types
Variable-intensity audible and visual alarms
Power Source
Two ‘D’ Alkaline Batteries
Warm-Up Time
10 seconds
Response Time
Instantaneous
Battery Life*
15 hours minimum
Probe
14” (35.6cm) flexible
Size
2” W x 9.4” L x 2.5” H
(5 cm W x 23.8 cm L x 6.3 cm H)
Weight
1.16 lb (0.53kg) w/ batteries
Agency Approvals
UL Listed in accordance with SAE J1627, CE
Warranty
One year, including sensor
*As tested in low sensitivity mode using Duracell Ultra MX 1300 alkaline batteries
Ordering Information
8
ServiceFirst
Item #
TOL02782
Mfg. #
19-8106
SEN01375
19-0559
Description
Tru Pointe®, instruction manual, 2 ‘D’ Batteries and hard carrying
case
Sensor
RSP-PRC035-EN
Leak Detection
H10PM
All-In-One Refrigerant Leak
Detector
H10PM Features
• Detects all CFC, HFC, and HCFC
Refrigerants
• Manual or automatic zero balance
control
• Pass/Fail Test mode
• Unique sensor calibration system
• 3 sensitivity modes
• Powered by a rechargable battery
• Pinpoints both small and large leaks
H10GFeatures
• Detects all CFC, HFC and HCFC
Refrigerants
• Manual zero balance control
• Pinpoints both small and large leaks
• AC powered
• 3 sensitivity modes
• 25 years of proven experience
Specifications
H10G
Manual Balance Refrigerant
Leak Detector
Detects:
Sensing Element:
Sensitivity:
R-134a
Warm-Up Time:
Performance:
Probe Length:
Dimensions / Weight:
H10PM
H10G
Operating Temp. Range:
Agency Listings:
Power:
H10PM
H10G
All CFC, HFC, and HCFC Refrigerants
Positive Ion Emission Heated Diode
Small - 0.1 oz/year
Medium - 0.5 oz/year
Large - 2.0 oz/year
Approx. 2 minutes
Exceeds SAE J1627
4.5 feet
5.5” x 10.5” x 8.5” / 5lbs.
(14cm x 27cm x 22cm / 2.3 Kg)
2.5” x 4.5” x 8.5” / 3lbs.
(6cm x 11cm x 22cm / 1.4 Kg)
32° TO 104°F (0° to 40°C)
UL File SA917, SAE J1627, CE-Mark
Internal, Rechargable Battery
(120VAC Charger Included)
Optional: 12V Battery Clamp Leads and Cigarette Adapter
Optional: 120V Charger for Charge or Run
120VAC Only
Zero Balance:
H10PM
H10G
Switchable Sens. Modes:
Alarm:
Manual and Auto
Manual Only
Yes
Audible and Visual
Ordering Information
ServiceFirst
Item #
Mfg. #
TOL02793
3015-0456
TOL02785
3015-0627
H10PM Accessories and Parts
ADP01131
3015-0131
BAT00055
3015-0103
H10G and H10PM Accessories and Parts
SEN01376
3015-0486
KIT13653
3015-0784
BOT00014
3015-0864
Description
H10G Standard Leak Detector *
H10PM All-in-One Leak Detector
AC Adapter (120V AC) (will charge or run unit)
Battery for H10PM
Replacement Sensor
Maintenance Kit
Leak Reference Bottle
* Specify power requirements when ordering.
RSP-PRC035-EN
9
Leak Detection
Informant® 2
The Informant® 2 leak detector allows
pinpoint detection of both refrigerant
and combustible gas leaks with the
same instrument.
Its unique combination of state-of-the-art
patented sensor technology, advanced
software design and microprocessorcontrolled circuitry offers you unmatched
precision coupled with tremendous
speed. The Informant® 2 utilizes a
patented semiconductor sensor
technology to detect combustible gases
and patented heated diode sensor
technology to detect refrigerants.
Swap sensor tips within seconds and
never worry about adjusting sensitivity
levels - it’s taken care of automatically even where high levels of background
vapors or refrigerants are present. The
refrigerant sensor tip is finely tapered to
a 0.2” diameter - so you can get in
between coils and fittings, gaining
access to hard to reach areas.
The Informant® 2 leak detector features
an audible indicator with a mute option
coupled with sequential LEDs to monitor
increasing concentrations of refrigerant
or combustible gases. Dual bar graph
displays offer visual confirmation no
matter what position the instrument is
in. And, a flashing light at the tip of the
probe helps to visually define your
sampling location.
10
Features and Benefits
• Detects both refrigerants and
combustible gases (with respective
sensor installed)
• Audible indicator with mute feature
• Sensor set at the tip for pinpoint
accuracy and instantaneous response
time
• Sensors are interchanged quickly
and easily
• Flashing probe tip, LED display
• Low battery indicator
• Optional boot and flashlight
• Lightweight and ergonomically
designed
• Microprocessor controlled for accuracy
and reliability
• Sensitivity is adjusted automatically
• Hydrophobic filter prevents moisture
contamination
• Rugged rubber boot holds flashlight
(optional)
• Flashing probe tip, dual LED displays
and loud tick rate indicates relative
concentration levels
• The Informant® 2 leak detector is a
modular system which is totally
upgradable. Order the complete dual
system or choose dedicated refrigerant
or combustible gas units and upgrade
to the dual configuration at any time in
the future.
• Lifetime warranty available
RSP-PRC035-EN
Leak Detection
Informant® 2 (continued)
Specifications
Sensing Elements:
Refrigerant
Combustible
Heated Diode - U.S. Patent No. 5,932,176
Patented semiconductor type. Five year typical life.
Plug-in replacement
All CFC, HCFC and HFC refrigerants including: R-12, R-22, R-123. R-134a and blends
R-404A, R-408A, R-409A and R-410A (i.e., any refrigerant containing Chlorine,
Flourine or Bromine gas)
Refrigerants Detected:
Combustible Gases
Detected:
Alarm Sensitivity:
Refrigerant
Combustible
Alarm Types:
Power Source:
Warm-up Time:
Response Time:
Refrigerant
Combustible
Battery Life:
Probe:
All combustible gases and vapors
Less than 0.25 oz/yr of R-134a (hardest to detect refrigerant)
Minimum 50ppm (Methane)
Audible, dual visual LED’s and flashing probe tip
Four (4) AA disposable alkaline batteries included
10 seconds
Instantaneous
Instantaneous
4-5 hours, under typical intermittent operation
20” (50.8 cm) maximum length, fully extended; 3” (7.62 cm) if wrapped around
instrument. Includes LED indicator
1.75”W x 9.62”L x 2.25”H (4.45 cm x 24.43 cm x 5.72 cm)
0.86 lbs. (0.39 kg) with batteries
Size:
Weight:
Agency Approvals:
Refrigerant
Combustible
UL listed in accordance with SAE J1627
MET Lab certified to UL 913, intrinsically safe for use in
Class1, Division 1, Group D hazardous areas
One year, including sensors
Warranty:
Ordering Information
RSP-PRC035-EN
ServiceFirst
Item #
TOL02689
Mfg. #
19-8038
TOL02706
19-8042
TOL02703
19-8045
SEN01377
SEN01347
FLR06598
19-0499
19-0510
19-0509
Description
Informant® 2 Contractor Kit.
Instrument comes with refrigerant and combustible gas sensors,
color-coded sensor tips, instruction manual, 4 AA batteries, filters
and a hard carrying case.
Dual Refrigerant/Combustible Informant® 2 Detector Kit.
Instrument comes with refrigerant and combustible gas sensors,
color-coded sensor tips, instruction manual, 4 AA batteries, 5
filters and a custom soft carrying case.
Dual Deluxe Refrigerant/Combustible Informant® 2 Detector Kit.
Instrument comes with refrigerant and combustible gas sensors,
color-coded probe tips, protective rubber boot, flashlight,
instruction manual, 6 AA batteries and 5 filters, all packaged in a
hard carrying case.
Replacement combustible sensor
Replacement refrigerant sensor
Replacement filters (5-pack)
11
Refrigerant Recovery Units
FM3700 Heavy Duty
Commercial Recovery Unit
Features
• 3/8” ports for faster, high-volume
refrigerant recovery
• Recovers ALL commonly used
refrigerants, including R-410A (Puron™)
• 450 PSI high pressure cut-off, high
pressure gauges
• High performance compressor
• Rugged and reliable
• Automatic shut-off when evacuation is
completed
Specifications
Refrigerants
Power Source
Compressor
Vacuum Rating
High Pressure Limit
Recovery Rate
All Refrigerants except R-11, R-113 and R-123
115 VAC 50/60 Hz, 230 VAC 50/60 Hz, 100 VAC 50/60 Hz
1 horsepower twin piston, high performance, oil-less
13” Hg+
450 PSI (31.0 bar)
.50 - 4.0 lbs./min. vapor, 8.0 lbs./min. liquid
0.23 - 1.81 Kg/min. vapor, 3.63 Kg/min. liquid
Auto 80% Tank
Shut Off
Self Purging System
Weight
Dimensions
Optional
No hose changes
47 lbs. (21.3 Kg)
12” x 14.25” x 8.75” (30.5cm x 36cm x 22cm)
Ordering Information
ServiceFirst
Item #
TOL02795
TOL02747
FM3600-410A Commercial
Recovery Unit
Mfg. #
2000-3700
2000-3701
Description
FM3700 Commercial Recovery Unit
FM3700 Commercial Recovery Unit with 80% shut-off
Features
• Recovers ALL commonly used
refrigerants, including R-410A (Puron™)
• 550 PSI high pressure cut-off, high
pressure gauges
• LED system status display
• Rugged and reliable
• Automatic shut-off when evacuation is
completed
Specifications
Refrigerants
Power Source
Compressor
Vacuum Rating
High Pressure Limit
Recovery Rate
All refrigerants except R-11, R-113 and R-123
115 VAC 50/60 Hz, 230 VAC 50/60 Hz, 100 VAC 50/60 Hz
0.5 HP high performance, oil less
13” Hg+
550 PSI (37.9 bar)
.30 - 2.0 lbs./min. vapor, 4.0 lbs./min. liquid
0.14 - 0.91 Kg/min. vapor, 1.81 Kg/min. liquid
Auto 80% Shut-Off
Optional
Self Purging System No hose changes
Weight
35 lbs.
Dimensions
12” x 13” x 7.5” (30.5cm x 33cm x 19cm)
Ordering Information
ServiceFirst
Item #
TOL02796
TOL02746
12
Mfg. #
2000-3600
2000-3601
Description
FM3600-410A Commercial Recovery Unit
FM3600-410A Commercial Recovery Unit with 80% shut-off
RSP-PRC035-EN
Refrigerant Recovery Units
Stinger
The improved Stinger, with its new
compressor, will evacuate refrigeration
systems faster than ever. The new
compressor, coupled with increased
condenser capacity, will speed up the
recovery process, even on the hottest
days. The Stinger’s rugged construction
will provide you with many seasons
of reliable operation. The Stinger is
capable of recovering all commonly
used* CFC, HFC and HCFC refrigerants,
including R-410A (Puron™). The unit is
easy to operate and is ideal for
evacuating both residential and light
commercial systems. A simple purge
system prevents cross-contamination of
refrigerants without changing hoses.
*Not for use with R-11, R-113 or R-123
New Compressor
• Lower cost of ownership - new
compressor is virtually maintenance
free
• 243% larger compressor piston enables
faster recovery
• Unlike competitive units, the new and
improved Stinger is capable of pulling a
vacuum for an extended period of time
without damaging the compressor
• The new compressor is capable of
running continuously on air for more
than 1,000 hours
Features
• Lightweight and compact - weights
only 24 pounds
• New compressor provides a 20%
increase in vapor recovery rate
• Recovers all commonly used CFCs,
HFCs and HCFCs, including R-410A
(Puron™)
• Capable of pumping virgin refrigerant
without damaging the compressor
• 1 year over the counter warranty
replacement
Specifications
Refrigerants
Power Source
Also Available
Compressor Type
Vacuum Rating
High Pressure Limit
R-22 Recovery Rates
(Cert. Per ARI 740-98)
Auto 80% Tank
Shut-Off
Self Purging System
Weight
Dimensions
Approvals
Certifications
R-12, R-22, R-114, R134a, R-401A, R-401B, R-401C, R-402A, R-402B, R-404A, R-406A,
R-407A, R-407B, R-407C, R-407D, R-408A, R-409A, R-410A, R-411A, R-411B, R-412A,
R-500A, R-502B, R-507, R-509
110/120 VAC, 1 Phase, 50/60 Hz, 8 Amps
220 VAC, 1 Phase, 50/60 Hz, 4 Amps
0.8 HP High Performance Oil-less
15” Hg+
550 PSI (37.9 bar)
Liquid: 3.88 lbs. / min. (1.76 kg / min.)
Vapor: 0.33 lbs. / min. (0.15 kg / min.)
Liquid Push / Pull: 14.00 lbs. / min. (6.35 kg / min.)
Optional
No Hose Changes
24 lbs. (11 kg)
11”H x 17”L x 9.5”W (28 cm x 43 cm x 24 cm)
Complies with UL 1963
Meets EPA requirements for recovery equipment
Conforms to ARI standard 740-98
Ordering Information
ServiceFirst
Item #
TOL02745
RSP-PRC035-EN
Mfg. #
2000-3300
Description
STINGER 115 VAC
13
Vacuum Pump / Swaging Kit /
Charging Scale
Vacuum Pump
Features
• Two stage rotary vane pump
• 1/4” and 3/8” fl are and 1/2” ACME
intake ports
• Light, compact and well balanced
• High performance vacuum, HP and
CFM ratings for all AC/R applications
• One year warranty
Specifications - QV5
Specifications - QV2
Voltage
Free Air Displacement
Ultimate
Vacuum
Motor
Motor Speed
Oil Capacity
Dimensions
Weight
110V/60Hz
1.7 CFM
0.03 mbar
15 Micron
1/4 HP
1720 rev/min
350 ml
358 x 172 x 290 (mm)
9.8 Kg (21.56 lbs)
Flaring, Swaging and
Cutting Kit
Features
• Most complete kit on the market
• 1/8" - 1-1/8" Tube Cutter
• Flaring tool flares 1/8" to 3/4" tubing
• AC Ratchet Wrench with 3/16", 1/4",
5/16" and 3/8" square sockets
• Five swaging heads sizes 3/16" to 3/4"
• Kit comes in a convenient plastic
molded case
Electronic Refrigerant Scale
Model CS100
Features
• Auto Zero feature
• Tethered display with flip-up stand
• Adjustable leveling feet with built-in
level indicator
• Handles a wide range of recovery
cylinders up to 330 lbs (150 kg)
• Auto power-off feature prevents
accidental battery drain
Voltage
Free Air Displacement
Ultimate
Vacuum
Motor
Motor Speed
Oil Capacity
Dimensions
Weight
110V/60Hz
5.3 CFM
0.03 mbar
15 Micron
1/2 HP
3450 rev/min
450 ml
358 x 180 x 300 (mm)
12 Kg (26.4 lbs)
Specifications
Units
Resolution
Accuracy
Capacity
Platform Dimensions
Power Supply
Lbs. / Lbs. - Oz. / Kg
0.05 lbs / 0.05 oz / 20 g
± 1% of reading
330 lbs (150 kg)
11”L x 11”W x 2”H
(27.9cm x 27.9cm x 5.1cm)
9-volt battery (included)
Ordering Information
ServiceFirst
Item #
PMP01742
PMP01743
TOL02773
TOL02770
14
Mfg. #
2002-0001
2002-0005
2002-6500
2010-0000
Description
QV2 Vacuum Pump
QV5 Vacuum Pump
Flaring, Swaging and Cutting Kit
Electronic Refrigerant Scale
RSP-PRC035-EN
Digital Multimeter (DMM)
Pocket Digital Multimeter
Features
• 4 functions
• Compact DMM with built-in case for
leads
• Auto power off
• Data-hold function
• Battery check function
• Auto-range
• Over-range and low batter indication
• Includes batteries, test leads and 1-year
warranty
Specifications
Functions
1. Volts
2. Amps
3. Ohms/Continuity
4. Diode Test
4000
400mV / 300V
400mA
300V
N/A
40M
N/A Ω
N/A
N/A
Both
Display Count
DC V
DC A
AC V
AC A
Resistance
Capacitance
Frequency
Temperature
CE or UL Listed
Ordering Information
ServiceFirst
Item #
TOL02778
RSP-PRC035-EN
Mfg. #
2002-0900
Description
MMP900 Pocket Digital Multimeter
15
Manifolds and Hoses
Manifold Set with Sight Glass,
R12/22/134a
Model No. MS040, R-12/22/134a
• Brass body with hook, hose holder and
2 hand wheels
• Includes 3 pieces 60” RYB hoses with
1/4” flare fittings. Hoses rated at 2500
psi.Burst / 500 psi Max W.P.
• 0-250 / 0-500 psi Gauges
Manifold Set with Sight Glass,
R-410A
Model No. MS430, R-410A
• Brass body with hook, hose holder and
2 hand wheels
• Includes 3 pieces 60” RYB hoses with
1/4” flare fittings. Hoses rated at 4000
psi Burst / 800 psi Max W.P.
• 0-500 / 0-800 psi Gauges
Ordering Information
ServiceFirst
Item #
MFD01160
MFD01161
Mfg. #
2002-4000
2002-4300
Description
Manifold Set with Sightglass, R-12/22/134a, Model MS040
Manifold Set with Sightglass, R-410A, Model MS430
Ball Valve Hose Set,
R-12/22/134a
Model No. BV3, R-12/22/134
• 3 pcs 6” RYB hoses with 1/4” flare
fittings
• Hoses rated at 2500 psi Burst / 500 psi
Max W.P.
• Hoses compatible with Manifold Set
models MS050 and MS040
Ball Valve Hose Set, R-410A
Model No. HS460, R-410A
• 3 pcs 60” RYB hoses with 1/4” flare
fittings
• Hoses rated at 4000 psi Burst / 800 psi
Max W.P.
• Hoses compatible with Manifold Set
models MS050, MS040, MS440 and
MS430
Ordering Information
ServiceFirst
Item #
HSE01529
HSE01527
16
Mfg. #
2002-0003
2002-4600
Description
Ball Valve Hose Set, R-12/22/134a, Model BV3
Ball Valve Hose Set, R-410A, Model HS460
RSP-PRC035-EN
Manifolds and Hoses
Ball Valve Hose Set, R-410A
Features
• 3 pcs 60” RYB hoses with 1/4” flare
fittings
• Hoses rated at 4000 psi
Burst / 800 psi Max W.P.
• Compatible with manifold sets
Ordering Information
ServiceFirst
Item #
HSE01350
Multi-Refrigerant Vacuum
Hose
Mfg. #
2002-0040
Description
Ball Valve Hose Set, R-410A, Model BV410A
Features
• All refrigerant vacuum hose
• 3/8” straight yellow
• 60” length
• For use with 4 port manifold block
Ordering Information
ServiceFirst
Item #
HSE01528
4-Port Manifold
Mfg. #
2002-4650
Description
Multi-Refrigerant Vacuum Hose
Features
• H.D. aluminum block
• 3/8” vacuum port fitting
• 1/4” flare hose fittings
• Protected gauges
• H.D. hanging hook
• Colour coded easy grip handles for
positive control
Ordering Information
ServiceFirst
Item #
MFD01162
MFD01163
RSP-PRC035-EN
Mfg. #
2002-4350
2002-4375
Description
4-Port Manifold, R-410A
4-Port Manifold, R-22/12/134a
17
Gauges
R-12/22/134a Gauges
Specifications
Model
Dial Size
Connection
Scale
Pressure
Color
MSG250
2 1/2”
1/8 NPT
°F, PSI, kg/cm2
250 psi
Blue
MSG550
2 1/2”
1/8 NPT
°F, PSI, kg/cm2
500 psi
Red
Ordering Information
ServiceFirst
Item #
GAG01066
GAG01067
R-410A Gauges
Mfg. #
2002-0250
2002-0550
Description
MSG250, R-12/22/134a
MSG550, R-12/22/134a
Specifications
Model
Dial Size
Connection
Scale
Pressure
Color
MSG410
2 1/2”
1/8 NPT
°F, °C, PSI, kg/cm2
500 psi
Blue
MSG420
2 1/2”
1/8 NPT
°F, °C, PSI, kg/cm2
800 psi
Red
Ordering Information
ServiceFirst
Item #
GAG01068
GAG01069
18
Mfg. #
2002-0410
2002-0420
Description
MSG410, R-410A
MSG420, R-410A
RSP-PRC035-EN
Service Tools
Refrigeration Wrenches
TOL02780, 2002-0122
Model #HTRW122
• 4 square openings
• 3/16”, 1/4”,5/16”, and 3/8”
TOL02781, 2002-0123
Model #HTRW123
• 3/16” and 1/4” square openings
• 1/2” and 9/16” hex openings
PVC Pipe Cutter
TOL02771, 2002-2120
Model #HT212
• Up to 1 5/8” capacity
Spring-Type Tubing Benders
TOL02772, 2002-1434
Model #HT1434
• 6 per pack
• Sizes 1/4” x 10” long;
5/16” x 10”; 3/8” x 10”
1/2” x 12”; 5/8” x 14”;
3/4” x 14”
Telescopic Mirror Set
TOL02779, 2002-0300
Model #HT31M
• Set of 4 mirrors
• Circular lens 1 1/4” Dia.,
4 3/4” to 19 1/2” extension
• Circular lens 2” Dia.,
8 1/2” to 18” extension
• Rectangular lens 2” x 3 1/2”,
8 1/2” to 19 1/4” extension
• Oval lens 1” x 2”
4 3/4” to 20 1/4” extension
RSP-PRC035-EN
19
Service Tools and Meters
Tubing Cutter
Features
• 1/8” to 1 1/8” O.D.
• Aluminum alloy body with chromeplated finish
• Includes 1 spare cutter wheel
Tamper Evident Straps
Features
• Protect against contamination
• Guard against unqualified repairs
• Warranty repairs with confidence
• Individually serial numbered
Anemometer
Features
• Ft/min: 0-8800
• Coiled Cable Vane Head
• Temperature: 32°F ~ 140°F (0°C ~ 60°C)
• Data hold and low battery indication
• Sensitive for low/high air velocity
• Also measures Km/hr, Knots, M/S
• Includes soft carrying case and battery
Ordering Information
ServiceFirst
Item #
TOL02774
SRP00919
TOL02775
20
Mfg. #
2002-1818
2003-000
2042-0000
Description
Tubing Cutter, Model No. HT1818
Tamper Evident Service Strap
Anemometer, Model No. TH4200
RSP-PRC035-EN
RSP-PRC035-EN
21
22
RSP-PRC035-EN
RSP-PRC035-EN
23
Literature Order Number
RSP-PRC036-EN
Filing Hierarchy
Service Products/Tools and Test Equipment/Test Instruments
Date
February 2006
Supersedes
New
Stocking Location
Print on Demand
Trane has a policy of continuous product and product data improvement and reserves the right to change
design and specifications without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement