UNIVERSAL MOTOR RUN
CAPACITOR KIT
• Universal permanent motor run capacitor manufactured to OEM performance and reliability requirements.
• Protected to 10,000 AFC.
• Safety features include full interrupter protection and thermal fuse.
• Every capacitor fully inspected including overrun testing at 700VAC voltage 60HZ for 1 minute, guaranteeing that it can be used in any potential condition.
• Advanced epoxy resin insulating material (UL file number E204979), minimum flammability class V-0.
• Tested and certified by Underwriters Laboratories listed to UL810 CYWT2/8.
• Internal modular construction ensures cooler running and more efficient heat dissipation.
• Single post failure does not render unit unusable,
Ratings Kit Includes MFR # SH #
67.5 MFD combined total capacitance
2.5/5.0/5.0/10.0/20.0/25.0 MFD,
370VAC or 440VAC, 50-60Hz
Capacitor, jumper wires, sticker, pen and instructions
MUNICAP200 MMUNICAP200
DIRECT BRAND LIMITED, 11B DEPOT STREET, SOUTH GRAFTON MA 01560, T 508-839-0013, F 508-519-0397 http://www.direct-brand.com/
PAGE 1 OF 1 − ISSUED 05/2015
Motor-Mate Universal motor-run capacitor
MFR#..MUNICAP200.....SH.ITEM.#MMUNICAP200
Universal permanent motor run capacitor manufactured to OEM performance and reliability requirements.
Replaces over 200 single and dual value capacitors.
Protected to 10,000 AFC.
Safety features include full interrupter protection and thermal fuse.
Every capacitor fully inspected including overrun testing at 700VAC voltage 60HZ for
1 minute, guaranteeing that it can be used in any potential condition.
Tested and certified by Underwriters
Laboratories listed to UL810 CYWT2/8.
Internal modular construction ensures cooler running and more efficient heat dissipation.
Specification
67.5mfd combined total capacitance
2.5/5.0/5.0/10.0/20.0/25.0mfd
370VAC or 440VAC
50-60Hz
Operating temperature range -40ºC to
+70ºC
CSA C22.2 No.190
UL File No. E311209
Single post failure does not render unit unusable, unlike single wound, multi-tapped capacitors.
Constructed to latest International
Environmental Standards.
Best quality materials used throughout.
US PATENT PROTECTED
7,987,593, 8,159,810 & 8,395,879
We strongly recommend that the installation is carried out by a qualified Service Technician.
Take care to follow the recommended fitting instructions carefully. Failure to do so will void the warranty and may lead to personal injury or damage to property.
Fire Hazard
Under no circumstances exceed the specified voltage. Ensure that component does not come into direct contact with water (for example, spray, dripping water or rain). Improper and dangerous operation can result from wiring errors.
Ensure that wiring is routed securely.
Shock Hazard
Always turn off electric power before working on any appliance. Ensure proper connection of jumper wires.
Explosion Hazard
Shut off main electrical supply to appliance before installation begins, and do not reconnect until installation is complete.