Document # PG05-006

DR30D, DR30DH, DR30DI, DR30DIH

Distinctive

30” Wide

Dual Fuel Range

Revised 06/13/13 Page 1/7

PLANNING

GUIDE

Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated.

46 3/8” (117.8 cm)

28 7/8” (73.3 cm)

28 1/2” (72.4 cm)

26 1/2” (67.3 cm)

24 3/8” (61.9 cm)

1 1/8” (2.9 cm)

Front of open door

Front of handle

Front of knobs

Control panel

Rear of control panel/oven door

warNINg

• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.

• This appliance must be installed in accordance with the accompanying installation instructions.

External handle shown, some models have integral handle

(see inside cover)

Width at front panel:

29 7/8” (75.9 cm)

9” (22.9 cm)

Backguard**

1 1/8” (2.9 cm) to cooking surface (top of grates) from top of trim

Full size side panel

3” (7.7 cm)

Backguard*

6” (15.2 cm)

Backguard**

35 3/4”

(90.8 cm) to

37 7/8”

(96.2 cm)

* Standard

** Optional

Optional Backguard and Island Trim Part Numbers

Description Part Number

Island trim kit (no backguard) ADTK30D

6 inch trim kit

9 inch trim kit

ADB3006

ADB3009

NOTE: Model DR30D[H] is NOT designed for self-rimming installation or installation with a raised vent.

PRoDUct DImENsIoNs - moDEL DR30D[H] (FREEstANDING moDEL)

External handle shown, some models have integral handle

(see inside cover)

Width at front panel:

29 7/8” (75.9 cm)

46 3/16” (117.3 cm)

28 11/16” (72.9 cm)

28 5/16” (71.9 cm)

26 5/16” (66.8 cm)

24 3/16” (61.4 cm)

1” (2.5 cm)

Front of open door

Front of handle

Front of knobs

Control panel

Rear of control panel/oven door

Rear trim overhang

5/16” (8 mm)

Trim thickness

1 7/16” (3.7 cm) to cooking surface (top of grates) from bottom of trim

35 7/16”

(90.0 cm) to

37 9/16”

(95.4 cm)

3 1/4” (8.3 cm)

Removable side panel

NOTES:

■ When installing model DR30DI[H] with a raised vent, install

only Dacor model ERV3015.

■ The backguards shown above for model DR30D[H] are NOT compatible with model DR30DI[H].

■ This model can be installed in a freestanding configuration between cabinets, provided the countertop is as high at the trim around the cooktop.

PRoDUct DImENsIoNs - moDEL DR30DI[H] (sELF-RImmING moDEL)

All specifications subject to change without notice.

www.dacor.com

Phone: (800) 793-0093

Document # PG05-006

DR30D, DR30DH, DR30DI, DR30DIH

Distinctive 30” Wide

Dual Fuel Range

Revised 06/13/13 Page 2/7

PLANNING

GUIDE

gas and Electrical requirements

gas Type

Natural gas gas Supply Pressure requirements*

Manifold Pressure

5” water column

Minimum gas Supply

Pressure

6” water column

LP 10” water column 11” water column

* Maximum input gas supply pressure for all models is 1/2 psi

The regulator inlet accommodates a 3/4” gas line. The range ships with a

1/2” to 3/4” adapter connected to the regulator.

Gas inlet

Range electrical access, cover removed

B

Electrical Specifications

Circuit required Total Connected Load

240 Vac, 60 Hz., 30 Amp.* 5.7 kW (23.8 Amp.)

* Two 120 Vac hot (L1 and L2), one neutral, one ground

D

A

C

7/8" to 1 1/8" dia. access hole connection hole in bottom*

The ratings above are for reference only - refer to the range's product data label for exact specifications.

The correct voltage, frequency and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 and L2).

ranges equipped for installation in Canada:

■ Freestanding ranges used in Canada require a factory installed 4-wire appliance cord and

NEMA 14-50P plug. Order model number

DR30D-C or DR30DH-C. The appliance cord is

66 inch (168 cm) long.

■ Do not modify the factory wiring. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician.

NEmA 14-50R

REcEPtAcLE

■ all other models:

The wiring needs to be long enough to allow the range to be pulled out for service, while remaining connected (see following page).

The wiring connected to the range must:

Meet NEMA standards and have a minimum rating of 250 Volts @ 30

Amp.

Include a strain relief.

Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends.

■ Connect to a junction box or receptacle installed by a licensed electrician.

Where local code permits, a 3 or 4 wire appliance cord may be used. It must:

Be UL listed type SRD or SRDT.

Be equipped with a NEMA 14-50P 4-wire plug or, where local code permits, a NEMA 10-50P 3-wire plug.

a

4 3/4”

(12.1 cm)

B

22 1/8”

(56.2 cm)

C

8 3/4”

(22.2 cm)

D

13 3/4”

(34.9 cm)

GAs AND ELEctRIcAL DImENsIoNs

All specifications subject to change without notice.

www.dacor.com

Phone: (800) 793-0093

Document # PG05-006

DR30D, DR30DH, DR30DI, DR30DIH

Distinctive 30” Wide

Dual Fuel Range

Revised 06/13/13 Page 3/7

PLANNING

GUIDE

Cabinet Layout

■ Carefully check the location where the range is to be installed. For best performance, the range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.

To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood or raised vent (model DR30DI[H] only). A range hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets.

All maximum and minimum dimensions and clearances shown in the diagram below must be maintained for safe operation.

Any openings in the wall behind the appliance or in the floor underneath it must be sealed.

Carefully note the requirements stated below for clearances to walls and cabinets.

Cabinet tolerances: -1/16”, (+1.6 mm) -0

E gas and Electrical Service

■ The shaded area shown below denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations.

■ An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance.

The installation must allow for the following:

■ Access to the gas shut-off valve when the unit is installed.

Access to the remote circuit breaker panel/fuse box when the range is in place.

The gas supply piping, gas shut-off valve and the electrical junction box or receptacle must be located so they do not interfere with the range when it is installed.

The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.

10” min. (25.4 cm) to any combustibles above counter both sides

Non-combustible rear wall recommended

13” (33.0 cm) max.

5

Back wall 1

24 3/8” min.

(61.9 cm)

F

Cabinet face below countertop

18” (45.7 cm) min.

2, 5

30” (76.2 cm) min.

2

F

10” (25.4 cm) min.

to combustible side walls above the range

(both sides)

Countertop front cUtoUt FoR moDEL DR30D[H]

WItH sELF-RImmING tRIm KIt

PN AtKDR30DW-01

Note 6

Note 3

REqUIRED cAbINEt

DImENsIoNs

Suggested location of utilities 4

1 Minimum distance to a combustible rear wall for model

DR30DI[H] is 2.5” (6.4 cm) from top rear trim. Model DR30D[H] may be installed flush to rear wall, but non-combusible surface or 9-inch backguard (PNADB3009) is recommended.

2 Distance to combustible surfaces measured from cooking surface (top of cooktop grate); if installing an overhead range hood, also check the hood specifications for minimum required clearances.

3 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of cabinet front, see Product Dimensions.

4

5

Consult local code for exact location requirements.

This specification does not apply for cabinets located greater than a horizontal distance of 10” (25.4 cm) from the edge of the range.

6 Model DR30D[H]: 37 7/8 (96.2 cm) max.

Model DR30DI[H]: 37 7/16 (95.1 cm) max.

All specifications subject to change without notice.

www.dacor.com

E

Cutout Dimensions

36” (91.4 cm)*

30” (76.2 cm)**

30 1 /

16

F***

” (91.6 cm)

* Recommended ** Minimum

*** See following page for model DR30DI[H]

Phone: (800) 793-0093

Document # PG05-006

DR30D, DR30DH, DR30DI, DR30DIH

Distinctive 30” Wide

Dual Fuel Range

Revised 06/13/13 Page 4/7

PLANNING

GUIDE

Model Dr30DI[H] Self-rimming Installation without raised Vent

■ See pages 5/7 - 7/7 for raised vent installations.

Self-rimming installations create a “built-in” look where the trim of the range overlaps the surrounding countertop. It is also possible, if the cabinets are the right depth, to self rim the front of the range into the cabinet face, immediately behind the control panel and door trim.

When the front of the range is self-rimmed, the 3 1/4” side panels are removed.

It is not possible to self-rim the front of the range with countertop cutouts that are 30 inches wide.

Cabinet tolerances: -1/16”, (+1.6 mm) -0

Model Dr30DI[H] range with

H J K

Option 1

21”

(53.3 cm)

0” (0 cm) to

3 1/4” (8.3 cm)

0” (0 cm) to

5 3/8” (13.7 cm)

Option 2 1

24 1/4”

(61.6 cm)

NA

1 Side panels removed

Countertop height for all self-rimming installations:

35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum

0” (0 cm) to

2 1/8” (5.4 cm) oPtIoN 1: cUstom coUNtERtoP/stANDARD cAbINEt, toP sELF-

RImmED oNLy, 3 1/4 INcH sIDE PANELs Not REmovED

Rear wall or other vertical surface **

10” min.

(25.4 cm) both sides

1/4” min.* (6 mm)

countertop overhang oPtIoN 2: cUstom coUNtERtoP AND cAbINEt, toP AND FRoNt sELF-RImmED, 3 1/4 INcH sIDE PANELs REmovED

Rear wall or other vertical surface **

10” min.

(25.4 cm) both sides

1/4” min.* (6 mm)

countertop overhang

29 1/4” (74.3 cm) countertop opening

30” (76.2 cm) below countertop

H

J K toP vIEW overhang to width of cabinets below

To cabinet face below countertop

To countertop

front

* When increasing overhang, increase dimension H by same amount.

** Any vertical surfaces behind the range must be non-combustible unless countertop overhang exceeds 2 3/4” (7.0 cm).

Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm)

Combustible side wall above range

29 1/4” (74.3 cm) countertop and cabinet opening

H

K

Notch countertop to

30” (76.2 cm) toP vIEW

Cabinet face below countertop

To countertop

front

* When increasing overhang, increase dimension H by same amount.

** Any vertical surfaces behind the range must be non-combustible unless countertop overhang exceeds 2 3/4” (7.0 cm).

Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm)

See Top View for required distance to vertical surfaces

1/4” min. (6.4 mm) flat countertop min.

Range trim resting on countertop

See Top View for required distance to vertical surfaces

1/4” min. (6.4 mm) flat countertop min.

Range trim resting on countertop

Back of cutout

H

Countertop

Cabinet face

Back of control panel

3 1/4 inch side panel

DR30DI[H] range

sIDE vIEW

Back of cutout

H

Countertop

DR30DI[H] range

Range side panels removed

Cabinet face

Back of control panel and trim behind door rest against cabinet face sIDE vIEW

All specifications subject to change without notice.

www.dacor.com

Phone: (800) 793-0093

Document # PG05-006

23 15/16” min.

(60.8 cm)

Countertop

front toP vIEW

DR30D, DR30DH, DR30DI, DR30DIH

Distinctive 30” Wide

Dual Fuel Range

Revised 06/13/13 Page 5/7

PLANNING

GUIDE

Model Dr30DI[H] Self-rimming Installation without raised Vent (cont.)

.

oPtIoN 3: stANDARD coUNtERtoP AND cAbINEt, toP sELF-RImmED oNLy, 3 1/4 INcH sIDE PANELs Not

REmovED - AtKDR30DW-02 tRIm KIt REqUIRED

Cabinet tolerances: -1/16”, (+1.6 mm) -0

10” min. (25.4 cm) to any combustibles above counter both sides

Back of cutout

Non-combustible rear wall required*

5/8” min. (1.6 cm) countertop overhang in back

30” (76.2 cm) countertop/cabinet opening

Cabinet face below countertop

* Range trim overhangs countertop 9/16” in back. Rear wall must be noncombustible unless the rear wall is 2 1/2”

(6.4 cm) or more from range rear trim.

See Top View for required distance to vertical surfaces

1/4” min. (6.4 mm) flat countertop min.

Range trim resting on countertop

H

Countertop

Cabinet face

Back of control panel

3 1/4 inch side panel

Dr30DI[H] Self-rimming Installation with raised Vent

■ Only model DR30DI[H] may be installed with a raised vent. Use only

Dacor raised vent model ERV3015.

■ A self-rimming countertop configuration is required for raised vent installation. self-rimming installation of the range and raised vent create a “built-in” look where the range trim overlaps the countertop on both sides and the raised vent overlaps the countertop in back. It is also possible, if the cabinets are deep enough, to self rim the front portion of the range into the cabinet face immediately behind the control panel and door trim or behind the side panels. The rear range trim will partially cover the front of the raised vent chassis in back.

H

20 5/8”

(52.4 cm)

J

0” (0 cm) to

3 1/4” (8.3 cm)

K

0” (0 cm) to

5 3/8” (13.7 cm) oPtIoN 1: RANGE/RAIsED vENt combINAtIoN WItH cUstom coUNtERtoP/stANDARD cAbINEt, toP sELF-

RImmED oNLy, 3 1/4 INcH sIDE PANELs Not REmovED

Non-combustible rear wall recommended

10” min.

(25.4 cm) both sides

3/8” min. (1.0 cm) countertop overhang

27 1/2” (69.9 cm) raised vent opening

29 1/4” (74 3 cm) countertop opening

30” (76.2 cm) cabinet opening below countertop

Combustible side wall above range

H

2 9/16”

(6.5 cm)

J K toP vIEW overhang to width of cabinets

To cabinet face below countertop

To countertop

front

Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm)

28 11/16” (72.9 cm)

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

Range trim resting on countertop

Cabinet face

DR30DI[H] range

H

Countertop

DR30DI[H] range

Back of control panel

3 1/4 inch side panel sIDE vIEW

3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener sIDE vIEW

All specifications subject to change without notice.

www.dacor.com

Phone: (800) 793-0093

Document # PG05-006

DR30D, DR30DH, DR30DI, DR30DIH

Distinctive 30” Wide

Dual Fuel Range

Revised 06/13/13 Page 6/7

PLANNING

GUIDE

Dr30DI[H] Self-rimming Installation with raised Vent

(cont.)

oPtIoN 2: RANGE/RAIsED vENt combINAtIoN WItH cUstom coUNtERtoP AND cAbINEt, toP AND FRoNt sELF-RImmED, 3 1/4 INcH sIDE PANELs Not REmovED

Cabinet tolerances: -1/16”, (+1.6 mm) -0 oPtIoN 3: RANGE/RAIsED vENt combINAtIoN cUstom coUNtERtoP AND cAbINEt, toP AND FRoNt sELF-RImmED, 3 1/4 INcH sIDE PANELs REmovED

Cabinet tolerances: -1/16”, (+1.6 mm) -0

H

20 5/8” *

(52.4 cm)

K

0” (0 cm) to

5 3/8” (13.7 cm)

* Cabinet face below countertop must

be flush with back of notch in countertop

H

23 7/8” *

(60.6 cm)

K

0” (0 cm) to

2 1/8” (5.4 cm)

* Cabinet face below countertop must

be flush with back of notch in countertop

Non-combustible rear wall recommended

10” min.

(25.4 cm) both sides

3/8” min. (1.0 cm) countertop overhang

27 1/2” (69.9 cm) raised vent opening

29 1/4” (74 3 cm) countertop and cabinet opening

2 9/16”

(6.5 cm)

H

Combustible side wall above range

K

Notch countertop to

30” (76.2 cm) toP vIEW

Cabinet face below countertop

To countertop

front

Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm)

28 11/16” (72.9 cm)

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

H

Countertop

DR30DI[H] range

Range trim resting on countertop

Cabinet face

Back of side panel rests against cabinet face

3 1/4 inch side panel

ERV3015 raised vent

3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener sIDE vIEW

Non-combustible rear wall recommended

10” min.

(25.4 cm) both sides

27 1/2” (69.9 cm) raised vent opening

29 1/4” (74 3 cm) countertop and cabinet opening

3/8” min. (1.0 cm) countertop overhang

2 9/16”

(6.5 cm)

H

Combustible side wall above range

K

Notch countertop to

30” (76.2 cm) toP vIEW

Cabinet face below countertop

To countertop

front

Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm)

28 11/16” (72.9 cm)

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

Range trim resting on countertop

Countertop

H

DR30DI[H] range

ERV3015 raised vent

3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener

Range side panel removed

Cabinet face

Back of control panel and trim behind door rest against cabinet face sIDE vIEW

All specifications subject to change without notice.

www.dacor.com

Phone: (800) 793-0093

Document # PG05-006

DR30D, DR30DH, DR30DI, DR30DIH

Distinctive 30” Wide

Dual Fuel Range

Revised 06/13/13 Page 7/7

PLANNING

GUIDE

Model Dr30DI[H] Self-rimming Installation without raised Vent (cont.)

.

oPtIoN 4: RANGE/RAIsED vENt combINAtIoN WItH stANDARD coUNtERtoP AND cAbINEt, toP sELF-

RImmED oNLy, 3 1/4 INcH sIDE PANELs Not REmovED,

AtKDR30DW-03 tRIm KIt REqUIRED

Cabinet tolerances: -1/16”, (+1.6 mm) -0

Countertop height for all self-rimming installations:

35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum

10” min.

(25.4 cm) both sides

Non-combustible rear wall recommended

27 1/2” (69.9 cm) raised vent countertop opening

3/8” min. (1.0 cm) countertop overhang

2 9/16”

(6.5 cm)

30” (76.2 cm) countertop/cabinet opening

24 1/8” min.

(61.3 cm)

Cabinet face below countertop

Countertop front

28 11/16” (72.9 cm)

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

H

Countertop

DR30DI[H] range

Range trim resting on countertop

Cabinet face

Back of control panel

3 1/4 inch side panel

3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener

All specifications subject to change without notice.

www.dacor.com

Phone: (800) 793-0093

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement