30" (76.2 cm) and 36" (91.4 cm) Range Hood

30" (76.2 cm) and 36" (91.4 cm) Range Hood
30" (76.2 cm) and 36" (91.4 cm) Range Hood
PRODUCT MODEL NUMBERS
Calculating Vent System Length
KHSU205W
The recommended vent system is 6" (15.2 cm) round vent with a
maximum length of 26 ft (8 m). For the best performance, use no more
than three 90° elbows.
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
KHSU265W
ELECTRICAL REQUIREMENTS
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the model/serial
rating plate. The model/serial rating plate is located behind the left filter on the
rear wall of the range hood.
Range hood location should be away from strong draft areas, such as windows,
doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions
provide minimum clearance. Consult your cooktop/ range manufacturer
installation instructions before making any cutouts.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home
Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or
when such standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition, or with local codes.
Vent Piece
6" (15.2 cm)
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
Example vent system - 6" (15.2 cm)
6 ft (1.8 m)
3 ft
(0.93 m)
VENTING REQUIREMENTS
This range hood is factory set for venting through the roof or through the wall.
The vent system needed for installation is not included. A 6" (15.2 cm) round
vent system is recommended.
Roof Venting
Wall Venting
B
A
Wall cap
90˚ elbow
A
B
Maximum Length
= 26 ft (8 m)
1 - 90° elbow
1 - wall cap
9 ft (2.8 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 9.0 ft (2.8 m)
System length
= 14.0 ft (4.3 m)
Non-Vented (recirculating) Installations Through the Soffit/Cabinet
If it is not possible to vent cooking fumes and vapors to the outside, the
range hood can be used in the non-vented (recirculating) version, using
an activated carbon filter. Recirculation Kit Part Number 4396565 is
available from the dealer or an authorized parts distributor. Damper
installation is not required.
A
A
B
A. 6" (15.2 cm) vent
through the roof
B. Roof cap
A. 6" (15.2 cm) vent
through the wall
B. Wall cap
B
C
F
D
D
F
E
E
A. Ceiling
B. Vent cover
C. Soffit
D. 6" (15.2 cm) vent
E. Range hood
F. Cabinet
Page 1 of 2
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10267109A
11/16/09
PRODUCT DIMENSIONS
17³⁄₈" (44.1 cm) - 30" (76.2 cm) model
23³⁄₈" (59.4 cm) - 36" (91.4 cm) model
6" (15.2 cm)
9¾" (24.8 cm)
10" (25.4 cm)
⁵⁄₈" (1.6 cm)
¾" (1.9 cm)
3" (7.6 cm)
1⁹⁄₁₆" (4.0 cm)
11" (27.9 cm)
25¼" (64.1 cm) - 30" (76.2 cm) model
31¼" (79.4 cm) - 36" (91.4 cm) model
18" (45.7 cm) with screen extended
29⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model
35⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model
CABINET DIMENSIONS
30" (76.2 cm) or
36" (91.4 cm) min.
cabinet opening width
24" (61 cm) min.
30" (76.2 cm)
suggested max.
bottom of cabinet
to cooking surface
13" (33 cm)
cabinet depth
15" (38.1 cm)
min. clearance
upper cabinet
to countertop
36" (91.4 cm)
base cabinet
height
Page 2 of 2
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10267109A
11/16/09
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement