EC-TYPE EXAMINATION CERTIFICATE 1

EC-TYPE EXAMINATION CERTIFICATE  1
1
2
EC-TYPE EXAMINATION CERTIFICATE
Equipment or Protective systems intended for use in Potentially
Explosive Atmospheres - Directive 94/9/EC
3
EC-Type Examination Certificate No:
FM10ATEX0012
4
Equipment or protective system:
(Type Reference and Name)
MODEL 2410 TANK HUB
5
Name of Applicant:
Rosemount Tank Radar AB
6
Address of Applicant:
Gamlestadsvägen 18B,
SE-40251 Göteborg
Sweden
7
This equipment or protective system and any acceptable variation thereto is specified in the schedule to this
certificate and documents therein referred to.
8
FM Approvals Ltd, notified body number 1725 in accordance with Article 9 of Directive 94/9/EC of 23 March
1994, certifies that this equipment has been found to comply with the Essential Health and Safety Requirements
relating to the design and construction of equipment intended for use in potentially explosive atmospheres given
in Annex II to the Directive.
The examination and test results are recorded in confidential report number:
3035492EC dated March 17, 2014
9
Compliance with the Essential Health and Safety Requirements, with the exception of those identified in item 15
of the schedule to this certificate, has been assessed by compliance with the following documents:
10
11
12
EN 60079-0:2009, EN 60079-1:2007, EN 60079-7:2007, EN 60079-11:2007, EN 60079-26:2007,
EN 60079-27:2008 and EN 60529:1992 + A1:2000
If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to special
conditions for safe use specified in the schedule to this certificate.
This EC-Type Examination certificate relates only to the design, examination and tests of the specified
equipment or protective system in accordance to the directive 94/9/EC. Further requirements of the Directive
apply to the manufacturing process and supply of this equipment or protective system. These are not covered by
this certificate.
The marking of the equipment or protective system shall include:
TANK HUB:
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC, IP66 / IP67
TANK HUB (with Active Modem HART Board):
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC, IP66 / IP67
II 2(1) G Ex d e [ia IIC] IIB T4 Ta = -50ºC to +70ºC, IP66 / IP67
TANK HUB (with Passive Modem HART Board):
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC, IP66 / IP67
II 2(2) G Ex d e ib IIB T4 Ta = -50ºC to +70ºC, IP66 / IP67
Digitally signed by Mick Gower
DN: cn=Mick Gower, o=FM Approvals, ou,
[email protected],
c=GB
Date: 2015.08.04 10:54:25 +01'00'
Mick Gower
Certification Manager, FM Approvals Ltd.
Issue date:04th August 2015
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 020 (May/12)
Page 1 of 5
SCHEDULE
to EC-Type Examination Certificate No. FM10ATEX0012
13
Description of Equipment or Protective System:
The Model 2410 Tank Hub is powered with 24-48Vdc or 48-240Vac / 50Hz to 60Hz and handles data
transmissions between the control room and a number of Fieldbus devices. It has a Flameproof enclosure,
Increased Safety terminals, and also contains Intrinsically Safe circuitry for supplying energy to the
Intrinsically Safe location. The Fieldbus terminals will either have a FISCO output or an Entity output
depending on which fieldbus communications board is installed. The FISCO output electronics are
distinguished by option b= Tank Bus (Fieldbus - Power and Communication): F and the Entity output
electronics are distinguished by b = Tank Bus (Fieldbus Power and Communication): E. As an option, the
Model 2410 Tank Hub can also contain a Modem HART communication board. The Active HART
communications option has Intrinsically Safe entity output. The Passive HART Communications board is
isolated and receives power from an Intrinsically Safe barrier.
The Model Codes are as follows:
2410-abcdefghijklmn. Tank Hub.
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC; FISCO; IP66 / IP67
FISCO Parameters:
Uo = 15V, Io = 354mA, Po = 5.32W
a= Number of Tanks: Any single character.
b= Tank Bus (Fieldbus - Power and Communication): F.
c = Primary communication Bus: R, 4, E, A, B, 6 or 7.
d = Secondary Communication Bus (Non-IS): A, B, E, F, G, H, R, L, V, 0, 6, or 7.
e = Relay Output (SIS/SIL): 3, 2, F or 0. (Option 3 and 2 were not verified by FM Approvals)
f = Relay Outputs (Non-SIS/SIL): 1, 2, F, A or 0. (Option A was not verified by FM Approvals).
g = Integral Display: 1 or 0.
h = Power Supply: P.
i = Firmware: Any single character.
j = Hazardous Location Certification: E1, K1, K2 or K3.
k = Custody Transfer Type Approval: Any single character.
l = Housing: A or S.
m = Cable/Conduit Connections: 1, 2, G, E or M.
n = Mechanical Mounting: P, W or 0.
2410-abcdefghijklmn. Tank Hub.
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC; FISCO; IP66 / IP67
II 2(1) G Ex d e [ia IIC] IIB T4 Ta = -50ºC to +70ºC; Entity; IP66 / IP67
FISCO Parameters:
Uo = 15V, Io = 354mA, Po = 5.32W
Entity Parameters:
Uo = 23.1V; Io = 95.3mA; Po = 550mW
IIC: Co = 0.14μF, Lo = 3.9mH
IIB: Co = 1.0μF, Lo = 15mH
IIA: Co = 3.67μF, Lo = 33mH
a= Number of Tanks: Any single character.
b= Tank Bus (Fieldbus - Power and Communication): F.
c = Primary Communication Bus: R, 4, E, A, B, 6 or 7.
d = Secondary Communication Bus (HART®/4-20mA Active IS Input/Output): W, C or 8.
e = Relay Output (SIS/SIL): 3, 2, F or 0. (Option 3 and 2 were not verified by FM Approvals)
f = Relay Outputs (Non-SIS/SIL): 1, 2, F, A or 0. (Option A was not verified by FM Approvals).
g = Integral Display: 1 or 0.
h = Power Supply: P.
i = Firmware: Any single character.
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 020 (May/12)
Page 2 of 5
SCHEDULE
to EC-Type Examination Certificate No. FM10ATEX0012
j = Hazardous Location Certification: E1, K1, K2 or K3.
k = Custody Transfer Type Approval: Any single character.
l = Housing: A or S.
m = Cable/Conduit Connections: 1, 2, G, E or M.
n = Mechanical Mounting: P, W or 0.
2410-abcdefghijklmn. Tank Hub.
II 2(2) G Ex de [ib] IIB T4 Ta = -50ºC to +70ºC; FISCO; IP66 / IP67
II 2(2) G Ex d e ib IIB T4 Ta = -50ºC to +70ºC; Entity; IP66 / IP67
FISCO Parameters:
Uo = 15V, Io = 354mA, Po = 5.32W
Entity Parameters:
Ui = 30V; Ii = 300mA; Pi = 1W, Ci = 0; Li = 0
a= Number of Tanks: Any single character.
b= Tank Bus (Fieldbus - Power and Communication): F.
c = Primary Communication Bus: R, 4, E, A, B, 6 or 7.
d = Secondary Communication Bus (HART®/4-20mA Passive IS Input/Output): D or 9.
e = Relay Output (SIS/SIL): 3, 2, F or 0. (Option 3 and 2 were not verified by FM Approvals)
f = Relay Outputs (Non-SIS/SIL): 1, 2, F, A or 0. (Option A was not verified by FM Approvals).
g = Integral Display: 1 or 0.
h = Power Supply: P.
i = Firmware: Any single character.
j = Hazardous Location Certification: E1, K1, K2 or K3.
k = Custody Transfer Type Approval: Any single character.
l = Housing: A or S.
m = Cable/Conduit Connections: 1, 2, G, E or M.
n = Mechanical Mounting: P, W or 0.
2410-abcdefghijklmn. Tank Hub
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC; Entity; IP66/IP67
Entity Parameters (Fieldbus):
Uo = 15V, Io = 200mA, Po = 3W, Co = 1.99µF, Lo = 143µH
a = Number of Tanks: Any single character.
b = Tank Bus (Fieldbus Power and Communication): E.
c = Primary Communication Bus: R, 4, E, A, B, 6 or 7.
d = Secondary Communication Bus (Non-IS): A, B, E, F, G, H, R, L, V, 0, 6, or 7.
e = Relay Output (SIS/SIL): 3, 2, F or 0. (Option 3 and 2 were not verified by FM Approvals)
f = Relay Outputs (Non-SIS/SIL): 1, 2, F, A or 0. (Option A was not verified by FM Approvals)
g = Integral Display: 1 or 0.
h = Power Supply: P.
i = Firmware: Any single character.
j = Hazardous Location Certification: E1, K1, K2 or K3.
k = Custody Transfer Type Approval: Any single character.
l = Housing: A or S.
m = Cable/Conduit Connections: 1, 2, G, E or M.
n = Mechanical Mounting: P, W, X or 0.
2410-abcdefghijklmn. Tank Hub.
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC; Entity; IP66/IP67
II 2(1) G Ex d e [ia IIC] IIB T4 Ta = -50ºC to +70ºC; Entity; IP66/IP67
Entity Parameters (Fieldbus):
Uo = 15V, Io = 200mA, Po = 3W, Co = 1.99µF, Lo = 143µH
Entity Parameters (Active HART):
Uo = 23.1V, Io = 95.3mA, Po = 550mW
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 020 (May/12)
Page 3 of 5
SCHEDULE
to EC-Type Examination Certificate No. FM10ATEX0012
Group IIC: Co = 0.14μF, Lo = 3.9mH
Group C, IIB: Co = 1.0μF, Lo = 15mH
Group D, IIA: Co = 3.67μF, Lo = 33mH
a= Number of Tanks: Any single character.
b= Tank Bus (Fieldbus - Power and Communication): E.
c = Primary Communication Bus: R, 4 E, A, B, 6 or 7.
d = Secondary Communication Bus (HART®/4-20mA Active IS Input/Output): W, C or 8.
e = Relay Output (SIS/SIL): 3, 2, F or 0. (Option 3 and 2 were not verified by FM Approvals)
f = Relay Outputs (Non-SIS/SIL): 1, 2, F, A or 0. (Option A was not verified by FM Approvals).
g = Integral Display: 1 or 0.
h = Power Supply: P.
i = Firmware: Any single character.
j = Hazardous Location Certification: E1, K1, K2 or K3.
k = Custody Transfer Type Approval: Any single character.
l = Housing: A or S.
m = Cable/Conduit Connections: 1, 2, G, E or M.
n = Mechanical Mounting: P, W or 0.
2410-abcdefghijklmn. Tank Hub.
II 2(2) G Ex d e [ib] IIB T4 Ta = -50ºC to +70ºC; Entity; IP66/IP67
II 2(2) G Ex d e ib IIB T4 Ta = -50ºC to +70ºC; Entity; IP66/IP67 Entity Parameters (Fieldbus):
Uo = 15V, Io = 200mA, Po = 3W, Co = 1.99µF, Lo = 143µH
Entity Parameters (Passive HART):
Ui = 30V, Ii = 300mA, Pi = 1W, Ci = 0, Li = 0
a= Number of Tanks: Any single character.
b= Tank Bus (Fieldbus - Power and Communication): E.
c = Primary Communication Bus: R, 4, E, A, B, 6 or 7.
d = Secondary Communication Bus (HART®/4-20mA Passive IS Input/Output): D or 9.
e = Relay Output (SIS/SIL): 3, 2, F or 0. (Option 3 and 2 were not verified by FM Approvals)
f = Relay Outputs (Non-SIS/SIL): 1, 2, F, A or 0. (Option A was not verified by FM Approvals).
g = Integral Display: 1 or 0.
h = Power Supply: P.
i = Firmware: Any single character.
j = Hazardous Location Certification: E1, K1, K2 or K3.
k = Custody Transfer Type Approval: Any single character.
l = Housing: A or S.
m = Cable/Conduit Connections: 1, 2, G, E or M.
n = Mechanical Mounting: P, W or 0.
14
Special Conditions for Safe Use:
None
15
Essential Health and Safety Requirements:
The relevant EHSRs that have not been addressed by the standards listed in this certificate have been identified
and assessed in the confidential report identified in item 8.
16
Test and Assessment Procedure and Conditions:
This EC-Type Examination Certificate is the result of testing of a sample of the product submitted, in
accordance with the provisions of the relevant specific standard(s), and assessment of supporting
documentation. It does not imply an assessment of the whole production.
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 020 (May/12)
Page 4 of 5
SCHEDULE
to EC-Type Examination Certificate No. FM10ATEX0012
Whilst this certificate may be used in support of a manufacturer’s claim for CE Marking, FM Approvals Ltd
accepts no responsibility for the compliance of the equipment against all applicable Directives in all
applications.
This Certificate has been issued in accordance with FM Approvals Ltd’s ATEX Certification Scheme.
17
Schedule Drawings
A list of the significant parts of the technical documentation is annexed to this certificate and a copy has
been kept by the Notified Body.
18
Certificate History
Details of the supplements to this certificate are described below:
Date
Description
20th September 2010
Original Issue.
24th
February 2011
25th April 2012
25th March 2014
11th June 2014
04th August 2015
Supplement 1:
Report Reference: – 3035492rev110818 dated 18th January 2011.
Description of the Change: Clarification of the triplicated voltage clamping of the
FISCO output.
Supplement 2:
Report Reference: – Supplement 2 to 3035492EC dated 19th April 2012.
Description of the Change:
1. Addition of the optional Modem HART Board and modification to the internal
circuit;
2. Minor change to the product model code;
3. Examination of the equipment against EN60079-0:2009.
Supplement 3:
Report Reference: – 3035492rev140317 dated 25th March 2014.
Description of the Change: Added an option for additional printed circuit board
conformal coating type, HumiSeal 1B73 and HumiSeal 1B31.
Supplement 4:
Report Reference: – 3035492rev140210 dated 6th June 2014
1. Description of the Change: Minor modifications to drawings not affecting
compliance.
Supplement 5:
Report Reference: – 3055665 dated 3rd August 2015
Description of the Changes:
1. Corrected Code structure for passive HART output which was not correct on
previous revisions.
2. Added three new Model 2410 Tank Hub options having Entity outputs at the
Fieldbus terminals 1a-b & 2a-b.
3. Updated the description section of the certificate to add the Entity output version.
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 020 (May/12)
Page 5 of 5
Blueprint Report
Rosemount Tank Radar A (1000003453)
Class No
3610
Original Project I.D.
Certificate I.D.
3035492
FM10ATEX0012
Drawing No.
Revision Level
Drawing Title
Last Report
Electronic Drawing
00809-0100-2410
CA/June 2015
Reference Manual Rosemount 2410 Tank Hub
3055665
Yes (pdf)
03031-0589
A
Schematic Diagram 160 segment LCD Board
3035492
Yes (pdf)
03031-0590
AF
PWB LCD Board, 2 Line
2/10/14
Yes (pdf)
03031-0591
AR
CCA LCD Board, 2 Line
2/10/14
Yes (pdf)
125044-211
1
TRANSFORMER T1 DETAILED SPECIFICATIONS
3043551
Yes (pdf)
300530EN
BB
2410 Reference Manual
2/10/14
Yes (pdf)
7000001-082
2
PCB MH ACTIVE/PASSIVE NON-IS
2/10/14
Yes (pdf)
9240040-900
2
APPR. DWG. FM
3043551
Yes (pdf)
9240040-901
03
SYSTEM CONTROL DRAWING FM
3055665
Yes (pdf)
9240040-902
2
APPR. DWG. FM BLOCK DIAGRAM
3043551
Yes (pdf)
9240040-903
1
APPR. DWG. FM PCB PS
3035492
Yes (pdf)
9240040-904
1
APPR. DWG. FM PCB CB
3035492
Yes (pdf)
9240040-905
3
APPR. DWG. FM PCB MB
2/10/14
Yes (pdf)
9240040-906
1
APPR. DWG. FM PCB AR
3035492
Yes (pdf)
9240040-907
2
APPR. DWG. FM PCB MH ACTIVE
2/10/14
Yes (pdf)
9240040-908
2
APPR. DWG. FM NON IS PCB
2/10/14
Yes (pdf)
9240040-909
1
APPR. DWG. FM ½" NPT PLUG
3035492
Yes (pdf)
9240040-920
1
APPR. DWG. FM M16x1.5 PLUG
3035492
Yes (pdf)
9240040-921
1
APPR. DWG. FM ¾" NPT PLUG
3035492
Yes (pdf)
9240040-946
2
Coating/Potting
3035492
Yes (pdf)
9240040-946
03
APPR. DWG. FM CONFORMAL
140317
Yes (pdf)
9240040-971
03
Model Code Description
3055665
Yes (pdf)
9240040-988
2
APPR. DWG. FM PCB MH PASSIVE
2/10/14
Yes (pdf)
D7000002-610
01
APPR. DWG. FM PCB PS ENTITY ROSEMOUNT 2410
3055665
Yes (pdf)
D7000002-611
01
SYSTEM CONTROL DWG. ROSEMOUNT 2410 ENTITY
3055665
Yes (pdf)
D9240040-937
03
Appr. DWG. Main Label Rosemount 2410
3055665
Yes (pdf)
Raptor-DE-0061
4
Explosion Protection Description
3043551
Yes (pdf)
04/08/2015
Page 1 of 1