2011 Products Guide V01 Bassano del Grappa (Vicenza) Headquarters Productive area: 12.500m2 Employees: 230 Production of: Chillers: air and water cooled, from 30 to 700kW Reversible units: air and water cooled, up to 400kW Multipurpose up to 400KW Chillers with free-cooling up to 300kW Pieve díAlpago (Belluno) Climaveneta Training centre Productive area: 7.000m2 Employees: 50 Production of: Air handling units Pieve d'Alpago (Belluno) Productive area: 25.000m2 Employees: 210 Production of: Chillers: air and water cooled, from 200 to 1700kW Heat pumps air and water cooled, up to 2400KW Multipurpose up to 700KW Chillers with free-cooling up to 1250kW Shell & tube evaporators Roof-top units up to 500kW Sometimes numbers say more than a thousand words And sometimes even a thousand words are not enough. Because it is hard to list all the reasons that explain why Climaveneta is the preferred partner air conditioning in the most challenging projects all around the world. - In fact our success is a delicate balance of vision, experience and cutting-edge technology. It is not just comfort, it is a question of flexibility and care, adapting the system to the requirements of each building and application, emulating their users’ needs. All over the world, no matter how harsh the climate, how demanding each project can be, every single choice is focussed on offering the most efficient, reliable and sustainable solution. Head offices and foreign branches Climaveneta SpA in Italy Climaveneta France Climaveneta Deutschland Climaveneta España Climaveneta Poland Climaveneta Chat Union Refrig. Equipment Co Ltd in China Distributors Over 55 distributors in more than 100 countries of the world for a truly complete market coverage. Service Service is assured in all countries through the assistance networks of our subsidiaries and distributors with highest expertise, a wide range of after sales service contracts for a truly complete support. Climaveneta. There are many reasons. Mignagola (Treviso) Productive area: 20.000m2 Employees: 160 Production of: Split systems, multisplit Chillers and Heat pumps up to 150kW Hydronic fan coils from 1 to 30kW Close control units Telecommunications units Shanghai (China) Sales department for China and far east Productive area: 25.000m2 Employees: 330 Production of: Air cooled chillers & heat pumps from 40 to 1700kW Water cooled chillers & heat pumps from 10 to 3070kW Parets del Valles (Spain) Productive area: 2.500m2 Employees: 45 Production of: Direc expansion units Compact units Rooftop units for small and medium applications Mission “To develop efficient and reliable air conditioning solutions in order to emulate our customers’ expectations”. Climaveneta is aware that the HVACR systems are among the most crucial in modern buildings. The use, energy efficiency and environmental sustainability of such spaces depend upon these systems, as well as the health and well-being of the people who spend their time there, whatever is the purpose - offices, residential, commercial centres, hotels, hospitals, leisure areas. 1st in Europe and 5th in the world This mission and values have been at the core of our activity for 40 years and have enabled us to become the 1st European manufacturer and the 5th world group in the HVACR industry. Achievements proven by the numbers of our group: 188 milions Euro turnover 2009 23 milions Euro EBITDA 2009 For 40 years mission and values have been leading our activity and are the basis of our results. Values Every strategic- and organizational choice is based upon fundamental values: Energy efficiency: continuous strive towards the most intelligent and sustainable use of energy resources, extended to all solutions, for both cooling and heating, with every type of product: complete efficiency, 365 days a year. Comfort: well-being created in enevery application with maximum efficiency and minimum environmental impact, thanks to the uncompromising attention to the specific requirements of each project. “Custom Made” approach: conjugate tailor-made solutions with advanced industrial processes, to ensure the answer to the needs of every user, application and building features, with the quality and advantages of a modern manufacturing organization. Environment and Social responsibility: continuously improve the sustainability of its activities and products, particularly in terms of energy consumption and environmental impact. A value which is witnessed by Climaveneta with the ISO 14001 certification, successfully obtained in December 2009. A complete range of products from 1 to 2400kW, a brand that is synonymous for reliability and quality, with all the advantages that only a leading group, De’Longhi, can offer, as far as manufacturing, know-how and customer orientation are concerned. All this is Climaveneta. Complete and specialized Organization Climaveneta qualifies itself for the consistency of both its proposal and organization. Specific approaches stem from such consistent yet broad offer, namely in Operations and R&D: the production is implemented in 5 focus factories, each specializing in terms of product types. Lean Manufacturing From the product to the system The whole production is structured according to lean thinking principles. It represents one of the best examples of lean manufacturing implementation in Europe. This commitment enables several advantages: We have integrated products into plug&play rational and efficient systems, complete with all the necessary components in order to ensure: Increased efficiency, Perfect comfort and complete adaptability to specific applications, Higher quality standardsi, High efficiency, Best process integration. Lower installation costs, Smooth and easy on site operations, Efficient project management thanks to Climaveneta as unique project leader. Integrated quality - envirionment - safety policy Climaveneta, consistently with the De’Longhi Group Policy – believes in the integrated Quality, Environment, Safety System as the best guarantee for all stakeholders in achieving the highest quality, reliability and competitiveness of the products and in complying with highest standards of safeguarding the environment and human resource safety. For further information www.climaveneta.com This company participates in the Eurovent Certification Programme. The products are listed in the Directory of certified products. The Eurovent certificate, for the applicable units, refers to products with cooling capacity up to 600 kW, voluntarily extended up to 1500 kW, for air-cooled models and up to 1500 kW for water-cooled models. Climaveneta S.p.A.: Environmental Management System complying with the requirements of UNI EN ISO14001:2004 norm Quality System complying with the requirements of UNI EN ISO9001:2008 norm Legenda Functions Fan Cooling Axial fan Heating Centrifugal fan Combined production of heating, cooling and domestic hot water Plug fan Combined production of heating and cooling Tangential fan REVERSIBLE HEAT PUMP Domestic hot water production Recovery Free-cooling Plate heat recovery Humidification ROTARY Reheat Further features Thermodynamic effect 2 PIPES Integrated electronic controller (can be optional) Suitable for 2-pipe system ENERGY CLASS 4 PIPES Suitable for 4-pipe system Compressor Rotary enthalpy recovery Class A Energy efficiency Leakage class B according to BS EN 1886 Eurovent Certification Centrifugal compressor VSpeed Scroll compressor Reciprocating compressor Rotary compressor Screw compressor Refrigerant VAir VPF Patent Pending 4 patents pending Refrigerant Water heat exchanger Tipologia Plate heat exchanger Wall split Shell & tube heat exchanger WALL Cassette CASSETTE Duct DUCT Vertical/Orizzontal FAN COIL The functions and characteristics are subject to each model’s size, configuration, optional. Performance data, pictures, schematics and other features contained in this document are provided exclusively on informational purpose about our product range. They refer to standard execution, applicable to the European Union market. They can be varied any time without notice. For further information please contact Climaveneta Sales/Marketing Offices or visit www.climaveneta.it. Index Hydronic - residential Functions Pag. Product Refrig. Compressors Heat Exchangers Fan Capacity COOLING HEATING SCROLL AXIAL • • CENTRIFUGAL PLATES • • • • • • Chillers, air source 16 20 22 24 BRAT MICS BRA MICS-C 4,9 - 32,9 kW 18,2 - 44,7 kW 4,9 - 15,4 kW 18,2 - 31,8 kW • • • • R410A R410A R410A R410A • • • • 5,5 - 35,1 kW • R410A • • 4,7 - 32,4 kW 8,6 - 41,9 kW • • R407C • • 4,6 - 35,5 kW 17,3 - 47,9 kW 4,6 - 16,8 kW 17,3 - 33,9 kW • • • • • • • • R410A R410A R410A R410A • • • • • • R410A • Chillers, water source 26 BRH Condenserless chillers 30 32 HE FF NHCR Reversible units, air source 34 38 40 42 BRAN MICS-N BRN MICS-CN • • • • • • • • Reversible units, water source 44 WWr MTD 5,2 - 41,7 kW • PRANA Functions Pag. Product Refrig. Compressors Heat Exchangers Fan Capacity COOLING HEATING HOT WATER SCROLL AXIAL EC FAN PLATES • • Reversible heat pump with inverter compressor, total heat recovery, air source 48 i-NRG 16,3 kW • • • R410A • • 50 AWR-DHW 7,7 - 33,5 kW • • • R407C • • • Reversible heat pump, air source 52 AWR-MTD1 6,9 - 17,4 kW • • • R410A • • • 54 AWR-MTD-XE 6,3 - 17,9 kW • • • R410A • • • • • R407C • • • Heat pump, air source 56 AW-HT 10,4 - 19,7 kW Reversible heat pump, water source 58 WWR-MTD 7,2 - 43,8 kW • • • R410A • • 60 WWR-HT Slim 8,3 - 14,1 kW • • • R407C • • 62 WWR-HT Cube 8,3 - 35,9 kW • • • R407C • • • • • R407C • • Reversible heat pump, total heat recovery, water source 64 WWR-DHW 6,0 - 40,5 kW Reversible heat pump, geothermal source 66 BWR-MTD 5,4 - 33,3 kW • • • R410A • • 68 BWR-HT Slim 6,2 - 10,6 kW • • • R407C • • 70 BWR-HT Cube 6,2 - 27,0 kW • • • R407C • • • • R407C • • Reversible heat pump, total heat recovery, geothermal source 72 BWR-DHW 4,5 - 29,7 kW • Hydronic - chiller Functions Pag. Product Refrig. Compressors Fan Heat Exchangers Capacity COOLING HEATING FREE COOLING SCROLL CENTRIFUGAL SCREW AXIAL CENTRIFUGAL PLATES SHELL & TUBES Chillers, air source for outdoor installation 76 NECS 33,8 - 341 kW • R410A • • • 82 NECS 53,0 - 159 kW • R410A • • • 86 NECS 354 - 885 kW • R410A • • • 90 94 98 100 104 106 110 NECS-ST FOCS FOCS FOCS FOCS-XL FOCS-CA i-FOCS 104 - 341 kW 145 - 516 kW 277 - 516 kW 294 - 1744 kW 272 - 1180 kW 310 - 1381 kW 511 - 842 kW • • • • • • • R410A R134a R134a R134a R134a R134a R134a • 112 TECS2 Vision 2.0 220 - 1325 kW • 114 120 124 NECS-FC FOCS-FC NECS-C 41,5 - 377 kW 329 - 1229 kW 37,1 - 325 kW • • • R134a • • • • • • • • • • • • • • • • • • • • • • • • R410A R134a R410A • • • • • • • • • • • Chiller, water source 128 130 NECS-W FOCS-W 43,4 - 371 kW 87,0 - 447 kW • • • • R410A R134a 132 FOCS2-W 321 - 1299 kW • • R134a 136 TECS2-W Vision 2.0 241 - 1949 kW • • R134a • • • • • • • Condenserless chiller 138 NECS-ME 39,5 - 432 kW • R410A 140 142 FOCS-ME FOCS-ME 79,2 - 410 kW 219 - 2240 kW • • R134a R134a • • • • • • Hydronic - reversible Functions Pag. Product Refrig. Compressors Fan Heat Exchangers Capacity COOLING HEATING FREE COOLING CENTRIFUGAL AXIAL CENTRIFUGAL PLATES SHELL & TUBES Reversible units, air source 146 NECS-N 35,8 - 322 kW • • R410A • 152 NECS-N 50,3 - 169 kW • • R410A • • 154 NECS-N 339 - 898 kW • • R410A • • 158 162 166 NECS-ST-N RECS RECS 103 - 322 kW 195 - 385 kW 195 - 385 kW • • • • • • R410A R134a R134a • • • • 170 FOCS-N 439 - 1160 kW • • R134a • 174 NECS-CN 36,0 - 303 kW • • R410A • • • • R410A R134a • • • • • • Reversible units, water source 176 178 NECS-WN RECS-W 43,4 - 371 kW 174 - 801 kW • • Reversible units, NRG line, total heat recovery, air source 180 NECS-NR 36 - 311 kW • • R410A • 184 NECS-NR 353 - 823 kW • • R410A • • • 188 FOCS-NR 200 - 826 kW • • R134a • • Reversible units, NRG line, total heat recovery, water source 192 NECS-WNR 5,7 - 491 kW • • R410A 194 FOCS-WNR 194 - 891 kW • • R134a • • INTEGRA Functions Refrig. Compressors Fan Heat Exchangers 4 PIPE Pag. Product Capacity SCROLL SYSTEM SCREW AXIAL PLATES • SHELL & TUBES INTEGRA unit for 4-pipe systems, air source 198 NECS-Q 36 - 311 kW • R410A • • 202 NECS-Q 353 - 823 kW • R410A • • 206 ERACS2-Q 200 - 826 kW • R134a • 210 i-FX-Q 479 - 811 kW • R134a • • • • • INTEGRA unit for 4-pipe systems, water source 214 NECS-WQ 45,7 - 491 kW • R410A 216 ERACS2-WQ 194 - 891 kW • R134a • • • • Hydronic terminals Type Pag. Product Functions Fan Capacity WALL FAN COIL CASSETTE DUCT 2 PIPES 4 PIPES • • • • • TANGENZIALE CENTRIFUGAL Fan-coils a-LIFE a-LIFE HP 1,45 - 22,42 kW 2,83 - 19,38 kW • • 234 i-LIFE 1,41 - 7,47 kW • • • 240 NFT 0,86 - 4,25 kW • • • 220 230 • • • • Hi-wall type terminals 244 MHD 1,9 - 4,6 kW • • • Ducted type terminals 250 254 HWD HWD-HP • • 4,8 - 29 kW 16,8 - 60,4 kW • • • • • • Heat recuperators 256 HRD • 290 - 4000 m3/h HPAC Functions Pag. Product Refrig. Compressors Fan Capacity COOLING SCROLL FREE COOLING AXIAL CENTRIFUGAL EC FAN Close control unit, direct expansion 260 i-AX 7 - 100 kW • R410A • 262 i-AW 7 - 100 kW • R410A • 264 266 268 270 272 ACCURATE AX ACCURATE AW ACCURATE AD ACCURATE AT ACCURATE AF 7 - 90 kW 7 - 90 kW 20-100kW 20-100kW 20-100kW • • • • • R410A R410A R410A R410A R410A • • • • • • • • • • • • Close control units, chilled water 274 278 ACCURATE AC ACCURATE AB 8 - 185 kW 20-110 kW • • • • Remote condensers 280 BRE R410A • 282 284 BRC ARCC R407C R407C • • Dry cooler 286 BDC • Packaged Functions Pag. Product Refrig. Compressors Recupero Sez. Int. Sez. Est. Capacity SCROLL COOLING HEATING FREE COOLING THERMODYNAMIC • • • • • • • • • • • • • R410A R410A R410A R410A • • • • PLATE ROTARY CENTRIFUGAL PLUG FAN AXIAL • • • • • • Rooftop units, for medium crowding applications 290 292 294 296 WORK WORK-T WHISPER WHISPER-T 37,4 - 198 kW 34,7 - 200 kW 35,7 - 197 kW 35,8 - 197 kW • • • Rooftop units with enthalpy recovery for medium crowding applications 298 i-WHISPER ENTHALPY 87,0 - 338 kW • • • • R410A • • • 300 302 304 WHISPER ENTHALPY WHISPER ENTHALPY-T WHISPER HALL 47,4 - 243 kW 47,4 - 243 kW 45,9 - 146 kW • • • • • • • • • • R410A R410A R410A • • • • • • • • • • • • • • R410A R410A • • • • R410A R410A • • • • • R410A R410A R410A R410A • • • • • • • • Rooftop units for medium crowding applications 306 308 WISDOM WISDOM-T 34,5 - 355 kW 34,7 - 357 kW • • • • • • • • Rooftop units with heat recovery for medium crowding applications 310 312 WISDOM-R WISDOM-T-R 43,0 - 422 kW 43,5 - 425 kW • • • • • • • • • • • • • WET line units for water loop systems 314 316 318 320 WET-RMT WET ENTHALPY WET-RTF WET-RTF-R 7,2 - 34,4 kW 50,6 - 262 kW 37,2 - 396 kW 44,8 - 468 kW • • • • • • Systems Pag. Product Group devices 324 325 MANAGER 3000 SEQUENCER Metering devices 326 DEMETRA Supervision devices 327 328 FWS3 FWS3000 IDRORELAX 330 IDRORELAX AHU Functions Pag. Product Fan Elettr. Capacity COOLING HEATING RE-HEATING HUMIDIFICATION CENTRIFUGAL PLUG FAN CONTROLLER • • • • • • • Air handling units 334 WIZARD 0-115000 m3/h Other Functions Pag. Product Refrig. Compressors Fan Capacity SCROLL COOLING RECIPROCATING AXIAL Condensing units 338 BRAT-MC 4,9 - 32,9 kW • R-410A • 340 344 348 HCAT MCAT NCE 38 - 160 kW 119 - 325 kW 55 - 389 kW • • R407C R407C R-410A • 352 FCE 79 - 894 kW R234A • • • • • • RO ONIC - REE O 14 hydronic residential ESIDENTIAL hydronic - residential 15 Hydronic - residential BRAT 0011÷0121 Versions FF FF-SL FFT FFT-SL base version, with built-in hydronic kit super-low noise version, with built-in hydronic kit base version without hydronic kit super-low noise version without hydronic kit Features Chillers, air source for outdoor installation 4,9 - 32,9 kW Unit Description BRAT is the Climaveneta range of air-cooled chillers with gas R410A. It is an outdoor unit with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Full Floating features The new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. 16 Coil protection grid for models 0011÷0061. Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. Phase sequence controller for models 0071÷0121 Differential pressure switch. Air vent valve. The hydronic circuit on the FF models includes: Circulating pump for models 0011÷0061. Multistage centrifugal pump for models 0071÷0121. Expansion tank. Safety valve. Manual filling assembly. Pressure gauge. Drain valve. Main accessories UÊRemovable metal mesh water filter kit UÊRubber anti-vibration mounting kit UÊCoil protection grid for models 0071÷0121 UÊAdditional circulating pump kit for models 0041÷0061 UÊExternal main switch kit UÊExternal buffer tank and hydronic connecting kit UÊHSW10 remote keyboard PLATES r HFC R-410A SCROLL AXIAL COOLING BRAT / FF Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current EER ESEER Nominal water flow Operational weight No. fans Useful head Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. kPa m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current EER ESEER Nominal water flow Operational weight No. fans Useful head Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P 0011 0021 0025 0031 0041 4,90 1,90 9,24 2,58 3,11 0,80 80 1 49 2400 SCROLL R410A 3/4” 54 65 230V~50Hz 5,60 2,10 9,84 2,67 3,35 1 85 1 46 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 6,90 2,50 12,4 2,76 3,33 1,20 100 1 42 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 8,60 3,40 15,6 2,53 3,28 1,50 105 1 41 4200 SCROLL R410A 3/4” 55 66 230V~50Hz 11 4,10 18,6 2,68 3,17 1,90 125 2 43 6800 SCROLL R410A 1” 1/4 58 69 230V~50Hz 900 640 370 900 640 370 900 940 370 900 940 370 900 1240 370 0041 kW kW A 11,4 4,20 8,38 2,71 3,30 m3/h 2 kg 125 N. 2 kPa 43 m3/h 6800 SCROLL R410A inches 1” 1/4 dB(A) 58 dB(A) 69 V-Ph~Hz 400V-3N~50Hz mm mm mm 900 1240 370 0021 0025 0031 5,60 7 8,70 2 2,40 3,10 4,24 4,44 5,94 2,80 2,92 2,81 3,37 3,37 3,34 1 1,20 1,50 85 100 105 1 1 1 46 42 41 3500 3500 4200 SCROLL SCROLL SCROLL R410A R410A R410A 3/4” 3/4” 3/4” 55 55 55 66 66 66 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 900 640 370 900 940 370 900 940 370 0051 0061 0071 0091 0101 0121 13,2 4,70 8,98 2,81 3,25 2,30 145 2 35 6800 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 15,4 5,20 9,68 2,96 3,51 2,70 155 2 32 6400 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 19,3 6,80 14,6 2,84 3,37 3,30 245 1 116 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 21,9 7,80 15,8 2,81 3,28 3,80 250 1 90 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 26,4 8,70 21,7 3,03 3,47 4,50 320 2 130 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 32,9 11,1 24,6 2,96 3,41 5,70 325 2 108 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 900 1240 370 900 1390 420 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions 17 BRAT / FFT Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current EER ESEER Nominal water flow Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current EER ESEER Nominal water flow Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P 0011 0021 0025 0031 0041 4,90 1,90 9,24 2,58 3,11 0,80 80 1 2400 SCROLL R410A 3/4” 54 65 230V~50Hz 5,60 2,10 9,84 2,67 3,35 1 85 1 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 6,90 2,50 12,4 2,76 3,33 1,20 100 1 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 8,60 3,40 15,6 2,53 3,28 1,50 105 1 4200 SCROLL R410A 3/4” 55 66 230V~50Hz 11 4,10 18,7 2,68 3,17 1,90 125 2 6800 SCROLL R410A 1” 1/4 58 69 230V~50Hz 900 640 370 900 640 370 900 940 370 900 940 370 900 1240 370 0041 kW kW A 11,4 4,20 8,38 2,71 3,30 m3/h 2 kg 125 N. 2 m3/h 6800 SCROLL R410A inches 1” 1/4 dB(A) 58 dB(A) 69 V-Ph~Hz 400V-3N~50Hz mm mm mm 900 1240 370 0021 0025 0031 5,60 7 8,70 2 2,40 3,10 4,24 4,44 5,94 2,80 2,92 2,81 3,37 3,37 3,34 1 1,20 1,50 85 100 105 1 1 1 3500 3500 4200 SCROLL SCROLL SCROLL R410A R410A R410A 3/4” 3/4” 3/4” 55 55 55 66 66 66 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 900 640 370 900 940 370 900 940 370 0051 0061 0071 0091 0101 0121 13,2 4,70 8,98 2,81 3,25 2,30 145 2 6800 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 15,4 5,20 9,68 2,96 3,51 2,70 155 2 6400 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 19,3 6,80 14,6 2,84 3,37 3,30 245 1 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 21,9 7,80 15,8 2,81 3,28 3,80 250 1 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 26,4 8,70 21,7 3,03 3,47 4,50 320 2 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 32,9 11,1 24,6 2,96 3,41 5,20 325 2 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 900 1240 370 900 1390 420 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions 18 BRAT / FF-SL Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current EER ESEER Nominal water flow Operational weight No. fans Useful head Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. kPa m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0071 0091 0101 0121 19,3 6,50 12,4 2,96 3,51 3,30 245 2 116 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 21,9 7,50 13,6 2,92 3,41 3,80 250 2 90 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 26,4 7,95 18,6 3,32 3,85 4,50 320 3 130 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 32,9 10,4 21,5 3,18 3,66 5,70 325 3 108 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 0071 0091 0101 0121 19,3 6,50 12,4 2,96 3,51 3,30 245 2 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 21,9 7,50 13,6 2,92 3,41 3,80 250 2 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 26,4 7,95 18,6 3,32 3,85 4,50 320 3 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 32,9 10,4 21,5 3,18 3,66 5,70 325 3 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions BRAT / FFT-SL Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current EER ESEER Nominal water flow Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions Dimension H H H P L P L P L 19 Hydronic - residential MICS 0072÷0182 Versions FF FFT base version, with built-in hydronic kit base version without hydronic kit Features Modular chillers, air source for outdoor installation 18,2 - 44,7 kW Unit Description MICS is the Climaveneta range of air-cooled liquid chillers. They are outdoor units with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Modular design MICS features an innovative design that optimises the possibilities of connecting up several units, reducing the necessary access space to a minimum and thereby the overall size of the units. Increasingly better capacity control The possibility of controlling up to six units as a single product means that MICS can increase the number of available control steps, thereby ensuring practically perfect adaptation to the real heat load trend. Keyboard Master Control KMC is the central control of the cascade modules. Its main function is to supervise operation of all the modules, making them operate synergically. As a user interface it has a graphic display and a keypad for navigating in the pull-down menus. Full Floating technology The full floating technology with automatic control of the airflow rate, water flow rate and water temperature gains a new function: Flex Energy, used to manage the capacity control steps in linear or alternating sequence in installations with several modules. 20 Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. Electronic expansion valve Available water pipe fittings in case of installation under appliance Differential pressure switch. Drain valve. The hydronic circuit on the FF models includes: Multistage centrifugal pump Air vent valve. Expansion tank. Safety valve. Pressure gauge. Main accessories UÊRubber anti-vibration mounting kit UÊRemovable metal mesh water filter kit UÊKit for connecting the KMC keyboard UÊCoil protection grids UÊKMC keyboard for modular system UÊRemote control kit PLATES AXIAL SCROLL r HFC R-410A COOLING MICS / FF Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Absorbed current Nominal water flow Operational weight No. fans No. Compressors Airflow Compressor type Hydraulic connections Refrigerant Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0072 0092 0122 0152 0182 18,2 6,50 2,80 4,05 14 3,10 310 1 2 9000 SCROLL 1”1/4 R410A 68 80 400V-3N~50Hz 23 9,30 2,47 3,93 19,1 4 330 1 2 9000 SCROLL 1”1/4 R410A 68 80 400V-3N~50Hz 31,8 10,7 2,97 3,98 22,2 5,50 410 2 2 18000 SCROLL 1”1/4 R410A 71 83 400V-3N~50Hz 39,4 13,5 2,92 4,12 27,8 6,80 450 2 2 18000 SCROLL 1”1/4 R410A 71 83 400V-3N~50Hz 44,7 15,5 2,88 4,17 31,5 7,70 480 2 2 18000 SCROLL 1”1/4 R410A 71 83 400V-3N~50Hz 1040 1630 790 1040 1630 790 1630 1630 790 1630 1630 790 1630 1630 790 0072 0092 0122 0152 0182 18,2 6,50 2,80 4,05 14 3,10 310 1 2 9000 SCROLL 1”1/4 R410A 68 80 400V-3N~50Hz 23 9,30 2,47 3,93 19,1 4 330 1 2 9000 SCROLL 1”1/4 R410A 68 80 400V-3N~50Hz 31,8 10,7 2,97 3,98 22,2 5,50 410 2 2 18000 SCROLL 1”1/4 R410A 71 83 400V-3N~50Hz 39,4 13,5 2,92 4,12 27,8 6,80 450 2 2 18000 SCROLL 1”1/4 R410A 71 83 400V-3N~50Hz 44,7 15,5 2,88 4,17 31,5 7,70 480 2 2 18000 SCROLL 1”1/4 R410A 71 83 400V-3N~50Hz 1040 1630 790 1040 1630 790 1630 1630 790 1630 1630 790 1630 1630 790 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions MICS / FFT Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Absorbed current Nominal water flow Operational weight No. fans No. Compressors Airflow Compressor type Hydraulic connections Refrigerant Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions Dimension H P L 21 Hydronic - residential BRA 0011÷0061 Versions FF FFT base version, with built-in hydronic kit base version without hydronic kit Features Chillers, air source for indoor installation 4,9 - 15,4 kW Coil protection grid for all models. Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. The circuit includes: Air vent valve. Water circulator. Differential pressure switch. Expansion tank. Safety valve. Pressure gauge. Manual filling assembly. Drain valve. Main accessories Unit Description BRA is the Climaveneta range of air-cooled liquid chillers with R410A refrigerant. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Full Floating features The new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. 22 UÊHSW10 remote keyboard UÊExternal buffer tank and hydronic connecting kit UÊExternal main switch kit UÊAdditional circulating pump kit for models 0041÷0061 UÊRubber anti-vibration mounting kit UÊRemovable metal mesh water filter kit PLATES CENTRIFUGAL r HFC R-410A SCROLL COOLING BRA / FF Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Absorbed current Nominal water flow Useful head Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kPa kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0011 0021 4,9 2,5 1,96 2,24 11,9 0,80 49 100 1 3200 SCROLL R410A 3/4” 55 68 5,6 2,6 2,15 2,48 12,5 1 46 105 1 3200 SCROLL R410A 3/4” 55 68 900 640 580 900 640 580 0025 0031 0041 0021 0025 11,0 5,2 2,11 2,39 24,6 1,90 43 165 2 6800 SCROLL R410A 1”1/4 60 71 5,6 2,6 2,15 2,54 6,90 1 46 105 1 3200 SCROLL R410A 3/4” 55 68 7,0 3,0 2,33 2,76 7,10 1,20 42 115 1 3600 SCROLL R410A 3/4” 55 68 900 940 580 900 1240 580 900 640 580 900 940 580 900 940 580 0031 0041 0021 0025 0031 11 5,2 2,11 2,39 24,6 1,90 165 2 6800 SCROLL R410A 1” 1/4 60 71 5,6 2,6 2,15 2,54 6,9 1 105 1 3200 SCROLL R410A 3/4” 55 68 7 3 2,33 2,76 7,1 1,20 115 1 3600 SCROLL R410A 3/4” 55 68 900 1240 580 900 640 580 900 940 580 6,9 8,6 3,1 4,0 2,23 2,15 2,68 2,60 15,1 18,3 1,20 1,50 42 41 115 125 1 1 3600 3600 SCROLL SCROLL R410A R410A 3/4” 3/4” 55 55 68 68 230V~50Hz 900 940 580 0031 0041 0051 0061 13,2 5,8 2,28 2,53 14,3 2,30 35 185 2 6800 SCROLL R410A 1”1/4 60 71 15,4 6,4 2,41 2,78 15 2,70 32 195 2 6800 SCROLL R410A 1”1/4 60 71 900 1240 580 900 1240 580 900 1390 630 0041 0051 0061 13,2 5,8 2,28 2,53 14,3 2,3 185 2 6800 SCROLL R410A 1” 1/4 60 71 15,4 6,4 2,41 2,78 15 2,7 195 2 6800 SCROLL R410A 1” 1/4 60 71 900 1240 580 900 1390 630 8,7 11,4 3,7 5,3 2,35 2,15 2,70 2,48 8,60 13,7 1,50 2 41 43 125 165 1 2 3600 6800 SCROLL SCROLL R410A R410A 3/4” 1”1/4 55 60 68 71 400V-3N~50Hz Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions BRA / FFT Modelli COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current EER ESEER Nominal water flow Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0011 0021 4,9 2,5 1,96 2,24 11,9 0,80 100 1 3200 SCROLL R410A 3/4” 55 68 5,6 2,6 2,15 2,48 12,5 1 105 1 3200 SCROLL R410A 3/4” 55 68 900 640 580 900 640 580 0025 6,9 8,6 3,1 4 2,23 2,15 2,68 2,6 15,1 18,3 1,20 1,50 115 125 1 1 3600 3600 SCROLL SCROLL R410A R410A 3/4” 3/4” 55 55 68 68 230V~50Hz 900 940 580 900 940 580 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions Dimension H P L 23 8,7 11,4 3,7 5,3 2,35 2,15 2,7 2,48 8,6 13,71 1,50 2 125 165 1 2 3600 6800 SCROLL SCROLL R410A R410A 3/4” 1” 1/4 55 60 68 71 400V-3N~50Hz 900 940 580 900 1240 580 Hydronic - residential MICS-C 0072÷0122 Versions FF base version, with built-in hydronic kit Features Chillers, air source for indoor installation Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. Electronic expansion valve Available water pipe fittings in case of installation under appliance The circuit includes: Multistage centrifugal pump Air vent valve. Differential pressure switch. Expansion tank. Safety valve. Pressure gauge. Drain valve. Main accessories 18,2 - 31,8 kW Unit Description MICS-C is the Climaveneta range of air-cooled liquid chillers with gas R410A. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Full Floating technology The new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. 24 UÊRubber anti-vibration mounting kit UÊRemovable metal mesh water filter kit UÊCoil protection grids UÊRemote control kit PLATES CENTRIFUGAL SCROLL r HFC R-410A COOLING MICS-C / FF Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Absorbed current Nominal water flow Operational weight No. fans No. Compressors Airflow Compressor type Hydraulic connections Refrigerant Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kg N. N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0072 0092 0122 18,2 6,50 2,80 4,05 16,1 3,10 330 1 2 9000 SCROLL 1”1/4 R410A 74 86 400V-3N~50Hz 23 9,31 2,47 3,93 19,8 4 350 1 2 9000 SCROLL 1”1/4 R410A 74 86 400V-3N~50Hz 31,8 10,7 2,97 3,98 27,3 5,50 450 2 2 18000 SCROLL 1”1/4 R410A 77 89 400V-3N~50Hz 1040 2000 790 1040 2000 790 1630 2000 790 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions Dimension H L P 25 Hydronic - residential BRH 0011÷0121 Versions FF FFT base version, with built-in hydronic kit base version without hydronic kit Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops (exchanger on plant side fitted with heating element for frost protection). External access to control with anti-tamper device. The safety of the unit is guaranteed by a door lock isolator on the electrical power switchboard and by active protection devices on the main components. The circuit includes: Modulating valve to reduce water consumptions (source side, FF versions only). Circulating pump (plant side, FF versions only). Air vent valve (plant side). Expansion vessel (plant side). Safety valve (plant side). Differential pressure switch on plant circuit only. Drain valve on both plant and source circuits. Chiller, water source Main accessories UÊRemovable metal mesh water filter kit UÊHSW10 remote keyboard 5,5 - 35,1 kW Unit Description BRH is a range of water-source liquid chillers operating with R410A refrigerant. These are indoor units with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Floating Set Once ever y 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. he water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times. Floating Flow The controller manages the modulation of the active components (pump and electronic flow valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimised for different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broader operating limits; easier start-up of installations with both high and low water temperatures; faster system setup. 26 r HFC R-410A SCROLL PLATES COOLING BRH / FF Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total power input (1) EER ESEER Water flow rate plant side (1) Absorbed current Operational weight Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW m3/h A kg inches dB(A) dB(A) V-Ph~Hz mm mm mm Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total power input (1) EER ESEER Water flow rate plant side (1) Absorbed current Operational weight Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P 0011 0021 0025 0031 0041 5,50 1,50 3,67 4,23 0,90 7,50 148 SCROLL R410A G 3/4” 41 52 230V~50Hz 5,90 1,70 3,47 3,92 1 8 148 SCROLL R410A G 3/4” 41 52 230V~50Hz 7,60 2 3,80 4,47 1,20 8,90 150 SCROLL R410A G 3/4” 42 53 230V~50Hz 9,20 2,60 3,54 4,15 1,50 12,3 152 SCROLL R410A G 3/4” 42 53 230V~50Hz 11,9 3,20 3,72 4,10 1,90 15,6 160 SCROLL R410A G 1”1/4 47 58 230V~50Hz 560 980 575 560 980 575 560 980 575 560 980 575 560 980 575 0041 kW kW 12,4 3,20 3,88 4,28 m3/h 2 A 7,40 kg 160 SCROLL R410A inches G 1”1/4 dB(A) 47 dB(A) 58 V-Ph~Hz 400V-3N~50Hz mm mm mm 560 980 575 0021 0025 0031 5,90 7,70 9,30 1,60 1,90 2,40 3,69 4,05 3,88 4 4,61 4,38 1 1,30 1,50 4,60 5 6,10 148 150 152 SCROLL SCROLL SCROLL R410A R410A R410A G 3/4” G 3/4” G 3/4” 41 42 42 52 53 53 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 560 980 575 560 980 575 560 980 575 0051 0061 0071 0091 0101 0121 13,9 3,80 3,66 4,22 2,30 8,10 170 SCROLL R410A G 1”1/4 47 58 400V-3N~50Hz 16,5 4 4,13 4,74 2,70 8,80 175 SCROLL R410A G 1”1/4 48 59 400V-3N~50Hz 20,8 5,10 4,08 4,62 3,40 12,2 220 SCROLL R410A G 1”1/4 55 66 400V-3N~50Hz 24 5,80 4,14 4,84 3,90 13,4 230 SCROLL R410A G 1”1/4 55 66 400V-3N~50Hz 27,3 6,80 4,01 4,55 4,50 16,1 235 SCROLL R410A G 1”1/4 59 70 400V-3N~50Hz 35,1 8,40 4,18 4,59 5,70 19,2 250 SCROLL R410A G 1”1/4 59 70 400V-3N~50Hz 560 980 575 560 980 575 680 1150 780 680 1150 780 680 1150 780 680 1150 780 Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Noise level measured at 1 m in open field conditions 27 BRH / FFT Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total power input (1) EER ESEER Water flow rate plant side (1) Absorbed current Operational weight Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW m3/h A kg inches dB(A) dB(A) V-Ph~Hz mm mm mm Models 0011 0021 0025 0031 0041 5,50 1,50 3,67 4,23 0,90 7,50 148 SCROLL R410A G 3/4” 41 52 230V~50Hz 5,90 1,70 3,47 3,92 1 8 148 SCROLL R410A G 3/4” 41 52 230V~50Hz 7,60 2 3,80 4,47 1,20 8,90 150 SCROLL R410A G 3/4” 42 53 230V~50Hz 9,20 2,60 3,54 4,15 1,50 12,3 152 SCROLL R410A G 3/4” 42 53 230V~50Hz 11,9 3,20 3,72 4,10 1,90 15,6 160 SCROLL R410A G 1”1/4 47 58 230V~50Hz 560 980 575 560 980 575 560 980 575 560 980 575 560 980 575 0041 COOLING ONLY VERSION Nominal Cooling capacity (1) Total power input (1) EER ESEER Water flow rate plant side (1) Absorbed current Operational weight Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW 12,4 3,20 3,88 4,28 m3/h 2 A 7,40 kg 160 SCROLL R410A inches G 1”1/4 dB(A) 47 dB(A) 58 V-Ph~Hz 400V-3N~50Hz mm mm mm 560 980 575 0025 0031 5,90 7,70 9,30 1,60 1,90 2,40 3,69 4,05 3,88 4 4,61 4,38 1 1,30 1,50 4,60 5 6,10 148 150 152 SCROLL SCROLL SCROLL R410A R410A R410A G 3/4” G 3/4” G 3/4” 41 42 42 52 53 53 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 560 980 575 560 980 575 560 980 575 0051 0061 0071 0091 0101 0121 13,9 3,80 3,66 4,22 2,30 8,10 170 SCROLL R410A G 1”1/4 47 58 400V-3N~50Hz 16,5 4 4,13 4,74 2,70 8,80 175 SCROLL R410A G 1”1/4 48 59 400V-3N~50Hz 20,8 5,10 4,08 4,62 3,40 12,2 220 SCROLL R410A G 1”1/4 55 66 400V-3N~50Hz 24 5,80 4,14 4,84 3,90 13,4 230 SCROLL R410A G 1”1/4 55 66 400V-3N~50Hz 27,3 6,80 4,01 4,55 4,50 16,1 235 SCROLL R410A G 1”1/4 59 70 400V-3N~50Hz 35,1 8,40 4,18 4,59 5,70 19,2 250 SCROLL R410A G 1”1/4 59 70 400V-3N~50Hz 560 980 575 560 980 575 680 1150 780 680 1150 780 680 1150 780 680 1150 780 Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Noise level measured at 1 m in open field conditions Dimension H L 0021 P 28 29 Hydronic - residential HE FF 0011÷0121 Versions FF base version, with built-in hydronic kit Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Differential pressure switch. The remote condenser may be installed up to a distance of 50 metres from the cooling unit. The safety of the unit is guaranteed by a door lock isolator on the electrical power switchboard and by active protection devices on the main components. Main accessories UÊBuffer tank plus pump UÊHydronic kit plus pump UÊRemovable metal mesh water filter kit UÊModulating pump kit UÊControl board for the modulating pump kit Condenserless units 4,7 - 32,4 kW Unit Description HH FF is the Climaveneta range of cooling units. These are indoor units that may be combined with remote outdoor condensers to guarantee maximum flexibility and compliance with any architectural restriction. These units have hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Full Floating features Once every 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. The water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times. 30 PLATES SCROLL r HFC R-407C COOLING HE FF Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Absorbed current Water flow in cooling Pressure drop Operational weight Compressor type Refrigerant Hydraulic connections Gas connection In/out gas water fittings Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A m3/h kPa kg inches inches inches dB(A) dB(A) V-Ph~Hz mm mm mm Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Absorbed current Water flow in cooling Pressure drop Operational weight Compressor type Refrigerant Hydraulic connections Gas connection In/out gas water fittings Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P 0011 0021 0025 0031 0021 0025 0031 4,70 1,60 2,84 3,20 7,67 0,90 22 68 SCROLL R407C 3/8” 1/2” 3/4” 43 --230V~50Hz 6,10 2,10 2,89 3,32 9,81 1,10 24 70 SCROLL R407C 3/8” 1/2” 3/4” 43 --230V~50Hz 7 2,50 2,80 3,22 11,6 1,30 26 71 SCROLL R407C 3/8” 5/8” 3/4” 48 --230V~50Hz 8,20 2,90 2,79 3,27 13,7 1,50 27 74 SCROLL R407C 3/8” 5/8” 3/4” 48 --230V~50Hz 6,10 2,10 2,94 3,41 3,77 1,10 24 70 SCROLL R407C 3/8” 1/2” 3/4” 43 --400V-3N~50Hz 7 2,40 2,86 3,30 4,56 1,30 26 71 SCROLL R407C 3/8” 5/8” 3/4” 48 --400V-3N~50Hz 8,20 2,90 2,86 3,38 5,22 1,50 27 74 SCROLL R407C 3/8” 5/8” 3/4” 48 --400V-3N~50Hz 400 960 450 400 960 450 400 960 450 400 960 450 400 960 450 400 960 450 400 960 450 0041 0051 0061 0071 0091 0101 0121 12,5 4,20 2,97 3,36 7,60 2,30 20 87 SCROLL R407C 1/2” 3/4” 1”1/4 52 --400V-3N~50Hz 15 4,90 3,07 3,81 8,81 2,80 20 90 SCROLL R407C 1/2” 3/4” 1”1/4 52 --400V-3N~50Hz 19,1 6,30 3,03 3,45 12 3,40 23 177 SCROLL R407C 5/8” 7/8” 1”1/4 52 --400V-3N~50Hz 22,2 7,80 2,86 3,22 14,1 4,10 22 180 SCROLL R407C 5/8” 7/8” 1”1/4 52 --400V-3N~50Hz 26,8 8,90 3 3,43 16,2 4,80 23 187 SCROLL R407C 3/4” 7/8” 1”1/4 53 --400V-3N~50Hz 32,4 10,9 2,96 3,32 18,9 5,90 23 190 SCROLL R407C 3/4” 7/8” 1”1/4 53 --400V-3N~50Hz 400 960 450 400 960 450 600 960 600 600 960 600 600 960 600 600 960 600 kW kW 10,5 3,40 3,06 3,54 A 6,20 m3/h 1,90 kPa 19 kg 85 SCROLL R407C inches 1/2” inches 3/4” inches 1”1/4 dB(A) 52 dB(A) --V-Ph~Hz 400V-3N~50Hz mm mm mm 400 960 450 Note: 1 Evaporator water (in/out): 12/7°C; Condensation temperature: 47°C. 2 Noise level measured at 1 m in open field conditions Dimension H L P 31 Hydronic - residential NHCR 0011÷0121 Versions NHCR base version Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish. The remote condenser may be installed up to a distance of 50 metres from the cooling unit. Finned coils made with copper pipes and aluminium fins with large exchange surface area. Remote condenser with axial fans 8,6 - 41,9 kW Unit Description NHCR are remote condensers with axial fans for condenserless units. 32 COOLING NHCR Models Nominal Cooling capacity (1) Fan Diameter Airflow RPM Total absorbed power (1) Absorbed current Current input at maximum conditions Electrical power supply Inlet connections Outlet connections Operational weight Attacco presa pressione No. fans COOLING ONLY VERSION Sound pressure level (2) DIMENSION L H P 0011 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121 kW mm m3/h n°/min kW A 8,6 1 x 400 2283 940 1 x 0,12 1 x 0,46 8,6 1 x 400 2283 940 1 x 0,12 1 x 0,46 17,2 2 x 400 4570 940 2 x 0,12 2 x 0,46 17,2 2 x 400 4570 940 2 x 0,12 2 x 0,46 17,2 2 x 400 4570 940 2 x 0,12 2 x 0,46 18,9 2 x 400 4058 940 2 x 0,12 2 x 0,46 25,8 3 x 400 6850 940 3 x 0,12 3 x 0,46 28,3 3 x 400 6080 940 3 x 0,12 3 x 0,46 28,3 3 x 400 6080 940 3 x 0,12 3 x 0,46 37,5 2 x 500 10440 890 2 x 0,29 2 x 1,15 41,9 2 x 500 9690 890 2 x 0,29 2 x 1,15 n° x A 1 x 0,55 1 x 0,55 2 x 0,55 2 x 0,55 2 x 0,55 2 x 0,55 3 x 0,55 3 x 0,55 3 x 0,55 2 x 1,25 2 x 1,25 V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz mm 14 14 20 20 20 22 24 28 28 35 35 mm 12 12 18 18 18 20 22 22 22 28 28 kg 33 33 37 37 37 46 66 66 73 93 101 inch 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” N. 1 1 2 2 2 2 3 3 3 2 2 dB(A) 35 35 38 38 38 38 40 40 40 42 42 mm mm mm 780 555 362 780 555 362 1380 555 362 1380 555 362 1380 555 362 1380 555 362 1830 555 362 1830 555 362 1830 555 362 2042 828 554 2042 828 554 Note: 1 The nominal capacity refers to a ∆t = 15°K. 2 Sound pressure measured at 10 m in open field conditions Dimension H L P 33 Hydronic - residential BRAN 0011÷0121 Versions FF FF-SL FFT FFT-SL base version, with built-in hydronic kit super-low noise version, with built-in hydronic kit base version without hydronic kit super-low noise version without hydronic kit Features reversible unit, air source for outdoor installation 4,6 - 35,5 kW Unit Description BRAN is the Climaveneta range of air-cooled reversible heat pumps with gas R410A. They are outdoor units with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Full Floating features The new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. 34 Condensate collecting tray for models 0011 ÷ 0061. Coil protection grid for models 0011÷0061. Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. Phase sequence controller for models 0071÷0121 Differential pressure switch. Air vent valve. The hydronic circuit on the FF models includes: Water circulator for models 0011 ÷ 0061 Multistage centrifugal pump for models 0071 ÷ 0121. Expansion tank. Safety valve. Manual filling assembly. Pressure gauge. Drain valve. Main accessories UÊRemovable metal mesh water filter kit UÊRubber anti-vibration mounting kit UÊCondensate collecting tray for models 0071 ÷ 0121 UÊCoil protection grid for models 0071÷0121 UÊAdditional circulating pump kit for models 0041÷0061 UÊExternal main switch kit UÊExternal buffer tank and hydronic connecting kit UÊHSW10 remote keyboard PLATES r HFC R-410A SCROLL AXIAL HEATING COOLING BRAN / FF Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow (1) Useful head (1) Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW kW kW A m3/h kPa kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow (1) Useful head (1) Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P 0011 0021 0025 0031 0041 4,6 1,9 2,42 2,96 5,7 2,3 2,48 10,6 0,80 49 90 1 2400 SCROLL R410A 3/4” 54 65 230V~50Hz 5,4 2,1 2,57 3,19 6,5 2,4 2,71 11,3 0,90 46 95 1 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 6,6 2,5 2,64 3,16 8,1 2,9 2,79 13,9 1,10 42 110 1 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 8,2 3,4 2,41 3,01 10,0 3,6 2,78 16,1 1,40 41 115 1 4200 SCROLL R410A 3/4” 55 66 230V~50Hz 10,4 4,1 2,53 3,01 12,4 4,5 2,76 21,2 1,80 43 140 2 6800 SCROLL R410A 1” 1/4 58 69 230V~50Hz 900 640 370 900 640 370 900 940 370 900 940 370 900 1240 370 0041 kW kW 10,8 4,2 2,57 3,13 kW 12,8 kW 4,7 2,72 A 9,28 m3/h 1,90 kPa 43 kg 140 N. 2 m3/h 6800 SCROLL R410A inches 1” 1/4 dB(A) 58 dB(A) 69 V-Ph~Hz 400V-3N~50Hz mm mm mm 900 1240 370 0021 0025 0031 5,3 6,7 8,2 2,0 2,4 3,1 2,65 2,79 2,64 3,21 3,41 3,17 6,4 8,0 9,7 2,4 2,7 3,2 2,67 2,96 3,03 4,84 4,94 6,14 0,90 1,20 1,40 46 42 41 95 110 115 1 1 1 3500 3500 4200 SCROLL SCROLL SCROLL R410A R410A R410A 3/4” 3/4” 3/4” 55 55 55 66 66 66 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 900 640 370 900 940 370 900 940 370 0051 0061 0071 0091 0101 0121 12,6 4,7 2,68 3,08 14,4 5,0 2,88 9,48 2,20 35 160 2 6800 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 14,6 5,2 2,81 3,33 16,8 5,4 3,11 9,98 2,50 32 170 2 6400 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 18,4 6,8 2,71 3,20 21,0 7,1 2,96 15,1 3,20 116 265 1 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 20,8 7,8 2,67 3,12 23,6 7,8 3,03 15,8 3,60 90 270 1 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 25,1 8,7 2,88 3,36 28,8 10,1 2,85 24,4 4,30 130 340 2 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 31,3 11,1 2,82 3,24 35,5 11,8 3,01 25,8 5,40 108 345 2 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 900 1240 370 900 1390 420 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions 35 BRAN / FFT Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow (1) Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW kW kW A m3/h kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow (1) Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P 0011 0021 0025 0031 0041 4,6 1,9 2,42 2,96 5,70 2,30 2,48 10,6 0,80 90 1 2400 SCROLL R410A 3/4” 54 65 230V~50Hz 5,4 2,1 2,57 3,19 6,50 2,40 2,71 11,3 0,90 95 1 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 6,6 2,5 2,64 3,16 8,10 2,90 2,79 13,9 1,10 110 1 3500 SCROLL R410A 3/4” 55 66 230V~50Hz 8,2 3,4 2,41 3,01 10 3,60 2,78 16,1 1,40 115 1 4200 SCROLL R410A 3/4” 55 66 230V~50Hz 10,4 4,1 2,53 3,01 12,4 4,50 2,76 21,2 1,80 140 2 6800 SCROLL R410A 1” 1/4 58 69 230V~50Hz 900 640 370 900 640 370 900 940 370 900 940 370 900 1240 370 0041 kW kW 10,8 4,2 2,57 3,13 kW 12,8 kW 4,70 2,72 A 9,28 m3/h 1,90 kg 140 N. 2 m3/h 6800 SCROLL R410A inches 1” 1/4 dB(A) 58 dB(A) 69 V-Ph~Hz 400V-3N~50Hz mm mm mm 900 1240 370 0021 0025 0031 5,3 6,7 8,2 2,0 2,4 3,1 2,65 2,79 2,64 3,21 3,41 3,17 6,40 8 9,70 2,40 2,70 3,20 2,67 2,96 3,03 4,84 4,94 6,14 0,90 1,20 1,40 95 110 115 1 1 1 3500 3500 4200 SCROLL SCROLL SCROLL R410A R410A R410A 3/4” 3/4” 3/4” 55 55 55 66 66 66 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 900 640 370 900 940 370 900 940 370 0051 0061 0071 0091 0101 0121 12,6 4,7 2,68 3,08 14,4 5 2,88 9,48 2,20 160 2 6800 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 14,6 5,2 2,81 3,33 16,8 5,40 3,11 9,98 2,50 170 2 6400 SCROLL R410A 1” 1/4 58 69 400V-3N~50Hz 18,4 6,8 2,71 3,20 21 7,10 2,96 15,1 3,20 265 1 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 20,8 7,8 2,67 3,12 23,6 7,80 3,03 15,8 3,60 270 1 9800 SCROLL R410A 1” 1/4 65 76 400V-3N~50Hz 25,1 8,7 2,88 3,36 28,8 10,1 2,85 24,4 4,30 340 2 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 31,3 11,1 2,82 3,24 35,5 11,8 3,01 25,8 5,40 345 2 14000 SCROLL R410A 1” 1/4 65 79 400V-3N~50Hz 900 1240 370 900 1390 420 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions 36 BRAN / FF-SL Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow (1) Useful head (1) Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW kW kW A m3/h kPa kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0071 0091 0101 0121 18,4 6,5 2,83 3,36 21,0 6,8 3,09 12,9 3,20 116 265 2 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 20,8 7,5 2,77 3,26 23,6 7,6 3,11 13,6 3,60 90 270 2 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 25,1 7,95 3,16 3,68 28,8 9,4 3,06 21,3 4,30 130 340 3 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 31,3 10,35 3,02 3,47 35,5 11,1 3,2 22,7 4,90 108 345 3 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 0071 0091 0101 0121 18,4 6,5 2,83 3,36 21,0 6,8 3,09 12,9 3,20 265 2 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 20,8 7,5 2,77 3,26 23,6 7,6 3,11 13,6 3,60 280 2 7000 SCROLL R410A 1” 1/4 62 73 400V-3N~50Hz 25,1 7,95 3,16 3,68 28,8 9,4 3,06 21,3 4,30 340 3 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 31,3 10,35 3,02 3,47 35,3 11,1 3,2 22,7 5,40 345 3 10500 SCROLL R410A 1” 1/4 63 74 400V-3N~50Hz 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions BRAN / FFT-SL Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow (1) Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW kW kW A m3/h kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions Dimension H H H P L P L A P 37 Hydronic - residential MICS-N 0072÷0182 Versions FF FFT base version, with built-in hydronic kit base version without hydronic kit Features Modular reversible unit, air source for outdoor installation 17,3 - 47,9 kW Unit Description MICS-N is the Climaveneta range of reversible air-cooled heat pumps. They are outdoor units with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Keyboard Master Control MICS features an innovative design that optimises the possibilities of connecting up several units, reducing the necessary access space to a minimum and thereby the overall size of the units. Increasingly better capacity control The possibility of controlling up to six units as a single product means that MICS can increase the number of available control steps, thereby ensuring practically perfect adaptation to the real heat load trend. Modular design KMC is the central control of the cascade modules. Its main function is to supervise operation of all the modules, making them operate synergically. As a user interface it has a graphic display and a keypad for navigating in the pull-down menus. Full Floating technology The full floating technology with automatic control of the airflow rate, water flow rate and water temperature gains a new function: Flex Energy, used to manage the capacity control steps in linear or alternating sequence in installations with several modules. 38 Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. Electronic expansion valve Available water pipe fittings in case of installation under appliance Differential pressure switch. Air vent valve. The hydronic circuit on the FF models includes: Multistage centrifugal pump Expansion tank. Safety valve. Pressure gauge. Drain valve. Main accessories UÊRemote control kit UÊKit for connecting the KMC keyboard UÊKMC keyboard for modular system UÊCoil protection grids UÊRemovable metal mesh water filter kit UÊRubber anti-vibration mounting kit PLATES SCROLL AXIAL r HFC R-410A HEATING COOLING MICS-N / FF Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal water flow Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow Hydraulic connections Operational weight No. fans Airflow Compressor type Refrigerant Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW m3/h kW kW A m3/h inches kg N. m3/h dB(A) dB(A) V-Ph~Hz mm mm mm 0072 0092 0122 0152 0182 17,3 6,50 2,66 3,86 3 20,2 6,50 3,11 14 3,50 1”1/4 310 1 9000 SCROLL R410A 68 80 400V-3N~50Hz 21,8 9,30 2,34 3,75 3,80 26,1 8,60 3,02 17,7 4,50 1”1/4 330 1 9000 SCROLL R410A 68 80 400V-3N~50Hz 30,3 10,7 2,83 3,78 5,20 33,9 11,2 3,03 23,9 5,90 1”1/4 410 2 18000 SCROLL R410A 71 83 400V-3N~50Hz 37,4 13,4 2,79 3,92 6,40 42,6 14 3,04 29,3 7,40 1”1/4 450 2 18000 SCROLL R410A 71 83 400V-3N~50Hz 42,5 15,5 2,74 3,96 7,30 47,9 15,4 3,11 31,3 8,30 1”1/4 480 2 18000 SCROLL R410A 71 83 400V-3N~50Hz 1040 1630 790 1040 1630 790 1630 1630 790 1630 1630 790 1630 1630 790 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions MICS-N / FFT Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal water flow Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow Hydraulic connections Operational weight No. fans Airflow Compressor type Refrigerant Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW m3/h kW kW A m3/h inches kg N. m3/h dB(A) dB(A) V-Ph~Hz mm mm mm 0072 0092 0122 0152 0182 17,3 6,50 2,66 3,86 3 20,2 6,50 3,11 14 3,50 1”1/4 310 1 9000 SCROLL R410A 68 80 400V-3N~50Hz 21,8 9,30 2,34 3,75 3,80 26,1 8,60 3,02 17,7 4,50 1”1/4 330 1 9000 SCROLL R410A 68 80 400V-3N~50Hz 30,3 10,7 2,83 3,78 5,20 33,9 11,2 3,03 23,9 5,90 1”1/4 410 2 18000 SCROLL R410A 71 83 400V-3N~50Hz 37,4 13,4 2,79 3,92 6,40 42,6 14 3,04 29,3 7,40 1”1/4 450 2 18000 SCROLL R410A 71 83 400V-3N~50Hz 42,5 15,5 2,74 3,96 7,30 47,9 15,4 3,11 31,3 8,30 1”1/4 480 2 18000 SCROLL R410A 71 83 400V-3N~50Hz 1040 1630 790 1040 1630 790 1630 1630 790 1630 1630 790 1630 1630 790 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions Dimension H P L 39 Hydronic - residential BRN 0011÷0061 Versions FF FFT base version, with built-in hydronic kit base version without hydronic kit Features Condensate collecting tray for all models Coil protection grid for all models. Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. The circuit includes: Air vent valve. Water circulator. Differential pressure switch. Expansion tank. Safety valve. Pressure gauge. Manual filling assembly. Drain valve. Reversible unit, air source for indoor installation 4,6 - 16,8 kW Main accessories Unit Description BRN is the Climaveneta range air-cooled heat pumps with gas R410A. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Full Floating features The new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. 40 UÊHSW5 remote keyboard UÊExternal buffer tank and hydronic connecting kit UÊExternal main switch kit UÊAdditional circulating pump kit for models 0041÷0061 UÊRubber anti-vibration mounting kit UÊRemovable metal mesh water filter kit PLATES SCROLL CENTRIFUGAL r HFC R-410A HEATING COOLING BRN / FF Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow Useful head Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW kW kW A m3/h kPa kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0011 0021 4,6 2,5 1,84 2,11 5,7 2,8 2,04 13,3 1 49 110 1 2200 SCROLL R410A 3/4” 55 68 5,4 2,6 2,08 2,37 6,5 2,9 2,24 14 1,40 46 125 1 2700 SCROLL R410A 3/4” 55 68 900 640 580 900 640 580 0025 0031 0041 0021 0025 10,4 5,2 2,04 2,44 12,4 5,7 2,21 26,6 1,70 43 135 2 2x3100 SCROLL R410A 1”1/4 60 68 5,3 2,6 2,23 2,62 6,4 2,9 2,42 7,50 1,10 46 115 1 2700 SCROLL R410A 3/4” 55 68 6,7 3,0 2,22 2,58 8,0 3,3 2,55 7,60 2,20 42 180 1 2400 SCROLL R410A 3/4” 55 68 900 940 580 900 1240 580 900 640 580 900 940 580 900 940 580 6,6 8,2 3,1 4,0 2,13 2,05 2,53 2,48 8,1 10,0 3,5 4,2 2,31 2,38 16,6 18,8 1,70 1,10 42 41 135 115 1 1 2400 3100 SCROLL SCROLL R410A R410A 3/4” 3/4” 55 55 68 68 230V~50Hz 900 940 580 0031 0041 0051 0061 12,6 5,8 2,17 2,40 14,4 6,1 2,36 14,8 2,50 35 200 2 2x3000 SCROLL R410A 1”1/4 60 71 14,6 6,4 2,28 2,62 16,8 6,5 2,58 15,3 2,90 32 210 2 2x3200 SCROLL R410A 1”1/4 60 71 900 1240 580 900 1240 580 900 1390 630 8,2 10,8 3,7 5,3 2 2,04 2,27 2,36 9,7 12,8 3,8 5,9 2,17 2,17 8,80 14,6 1,40 2,20 41 43 125 180 1 2 3100 2x3100 SCROLL SCROLL R410A R410A 3/4” 1”1/4 55 60 71 71 400V-3N~50Hz Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions BRN / FFT Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal Heating power Total absorbed power COP Absorbed current Nominal water flow Operational weight No. fans Airflow Compressor type Refrigerant Hydraulic connections Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW kW kW A m3/h kg N. m3/h inches dB(A) dB(A) V-Ph~Hz mm mm mm 0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061 4,6 5,7 1,84 2,11 5,7 2,8 2,04 5,4 6,5 2,08 2,37 6,5 2,9 2,24 6,6 8,1 2,13 2,53 8,1 3,5 2,31 8,2 10 2,05 2,48 10 4,2 2,38 10,4 12,4 2,04 2,44 12,4 5,7 2,21 5,3 6,4 2,23 2,62 6,4 2,9 2,42 6,7 8 2,22 2,58 8 3,3 2,55 8,2 9,7 2 2,27 9,7 3,8 2,17 10,8 12,8 2,04 2,36 12,8 5,9 2,17 12,6 14,4 2,17 2,4 14,4 6,1 2,36 14,6 16,8 2,28 2,62 16,8 6,5 2,58 1 110 1 2200 SCROLL R410A 3/4” 55 68 1,4 125 1 2700 SCROLL R410A 3/4” 55 68 1,7 135 2 2x3100 SCROLL R410A 1” 1/4 60 68 1,1 115 1 2700 SCROLL R410A 3/4” 55 68 2,2 180 1 2400 SCROLL R410A 3/4” 55 68 2,5 200 2 2x3000 SCROLL R410A 1” 1/4 60 71 2,9 210 2 2x3200 SCROLL R410A 1” 1/4 60 71 900 640 580 900 640 580 900 1240 580 900 640 580 900 940 580 900 1240 580 900 1390 630 1,7 1,1 135 115 1 1 2400 3100 SCROLL SCROLL R410A R410A 3/4” 3/4” 55 55 68 68 230V~50Hz 900 940 580 900 940 580 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Noise level measured at 1 m in open field conditions Dimension H P L 41 1,4 2,2 125 180 1 2 3100 2x3100 SCROLL SCROLL R410A R410A 3/4” 1” 1/4 55 60 71 71 400V-3N~50Hz 900 940 580 900 1240 580 Hydronic - residential MICS-CN 0072÷0122 Versions FF base version, with built-in hydronic kit Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. Electronic expansion valve Available water pipe fittings in case of installation under appliance The circuit includes: Multistage centrifugal pump Air vent valve. Differential pressure switch. Expansion tank. Safety valve. Pressure gauge. Drain valve. Reversible unit, air source for indoor installation 17,3 - 33,9 kW Main accessories Unit Description MICS-CN is the Climaveneta range air-cooled heat pumps with gas R410A. These are indoor units that, thanks to the ducted centrifugal fans, may also be installed outdoors. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Full Floating technology The new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. 42 UÊRubber anti-vibration mounting kit UÊRemovable metal mesh water filter kit UÊCoil protection grids UÊRemote control kit PLATES SCROLL CENTRIFUGAL r HFC R-410A HEATING COOLING MICS-CN / FF Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total absorbed power (1) EER ESEER Nominal water flow Nominal Heating power (2) Total absorbed power (2) COP Absorbed current Nominal water flow Hydraulic connections Operational weight No. fans Airflow Compressor type Refrigerant Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW m3/h kW kW A m3/h inches kg N. m3/h dB(A) dB(A) V-Ph~Hz mm mm mm 0072 0092 0122 17,3 6,50 2,66 3,86 3 20,2 6,50 3,11 16,1 3,50 1”1/4 310 1 9000 SCROLL R410A 74 86 400V-3N~50Hz 21,8 9,32 2,34 3,75 3,80 26 8,61 3,02 19,8 4,50 1”1/4 330 1 9000 SCROLL R410A 74 86 400V-3N~50Hz 30,3 10,7 2,83 3,78 5,20 33,9 11,2 3,03 27,3 5,90 1”1/4 410 2 18000 SCROLL R410A 77 89 400V-3N~50Hz 1040 2000 790 1040 2000 790 1630 2000 790 Note: 1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard 2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard 3 Noise level measured at 1 m in open field conditions Dimension H L P 43 Hydronic - residential WWr MTD 011m÷121t Versions WWr MTD base version Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. External access to control with anti-tamper device. User interface with display. The safety of the unit is guaranteed by a door lock isolator on the electrical power switchboard and by active protection devices on the main components. The circuit includes: Circulating pump (plant side, FF versions only). Air vent valve (plant side). Modulating valve to reduce water consumptions (source side, FF versions only). Expansion vessel (plant side). Safety valve (plant side). Differential pressure switch on both plant and source circuits. Drain valve on both plant and source circuits. Reversible unit, water source Main accessories UÊRemovable metal mesh water filter kit UÊExternal temperature sensor (mandatory with HSW12 remote keyboard) UÊHSW12 remote keyboard 5,2 - 41,7 kW Unit Description WWr MTD is the Climaveneta range of water-cooled heat pumps provided with R410A refrigerant. These are indoor units with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness. Commands Floating Set Once ever y 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. he water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times. Floating Flow The controller manages the modulation of the active components (pump and electronic flow valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimised for different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broader operating limits; easier start-up of installations with both high and low water temperatures; faster system setup. 44 r HFC R-410A SCROLL PLATES COOLING HEATING WWr MTD Models HEAT PUMP MODEL Nominal Cooling capacity (1) Total power input (1) EER ESEER Water flow rate plant side (1) Heating capacity (2) Total absorbed power (2) COP Water flow rate plant side (2) Absorbed current Operational weight Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P kW kW m3/h kW A kg inches dB(A) dB(A) V-Ph~Hz 011m 021m 025m 031m 041m 5,20 1,50 3,47 4,03 0,90 6,80 1,70 4 1,20 7,50 148 SCROLL R410A G 3/4” 41 52 230V~50Hz 5,60 1,70 3,29 3,73 1 7,50 1,90 3,95 1,30 8 148 SCROLL R410A G 3/4” 41 52 230V~50Hz 7,20 2 3,60 4,26 1,20 9,20 2,30 4 1,60 8,90 150 SCROLL R410A G 3/4” 42 53 230V~50Hz 8,80 2,60 3,38 3,95 1,50 11,6 3 3,87 2 12,3 152 SCROLL R410A G 3/4” 42 53 230V~50Hz 11,3 3,20 3,53 3,90 1,90 14,6 3,60 4,06 2,50 15,6 160 SCROLL R410A G 1”1/4 47 58 230V~50Hz 560 980 575 560 980 575 560 980 575 560 980 575 560 980 575 mm mm mm Models 021t HEAT PUMP MODEL Nominal Cooling capacity (1) Total power input (1) EER ESEER Water flow rate plant side (1) Heating capacity (2) Total absorbed power (2) COP Water flow rate plant side (2) Absorbed current Operational weight Compressor type Refrigerant Hydraulic connections Sound pressure level (3) Sound power Electrical power supply DIMENSION L H P 025t 031t 041t 061t 071t 091t 101t 121t kW kW 5,60 7,30 8,90 11,8 13,2 15,7 19,8 22,9 26 33,4 1,60 1,90 2,40 3,20 3,80 4 5,10 5,80 6,80 8,40 3,50 3,84 3,71 3,69 3,47 3,93 3,88 3,95 3,82 3,98 3,81 4,39 4,17 4,08 4,02 4,51 4,40 4,61 4,33 4,37 m3/h 1 1,30 1,50 2 2,30 2,70 3,40 3,90 4,50 5,70 7,40 9,20 11,4 15,3 17,1 20 24,8 28,8 33 41,7 kW 1,90 2,20 2,70 3,70 4,20 4,60 5,80 6,40 7,60 9,50 3,89 4,18 4,22 4,14 4,07 4,35 4,28 4,50 4,34 4,39 1,30 1,60 2 2,60 2,90 3,40 4,30 5 5,70 7,20 A 4,60 5 6,10 7,40 8,10 8,80 12,2 13,4 16,1 19,2 kg 148 150 152 160 170 175 220 230 235 250 SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A inches G 3/4” G 3/4” G 3/4” G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 dB(A) 41 42 42 47 47 48 55 55 59 59 dB(A) 52 53 53 58 58 59 66 66 70 70 V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz mm mm mm 560 980 575 560 980 575 560 980 575 560 980 575 Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out), 10/5°C, condenser water (in/out) 40/45°C, based on Eurovent standard 3 Sound pressure measured at 1 m in open field conditions Dimension H L 051t P 45 560 980 575 560 980 575 680 1150 780 680 1150 780 680 1150 780 680 1150 780 PRANA i-NRG 0061m÷0061t Versioni i-NRG Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation Features Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kW Unit description The new i-NRG heat pump provides exactly the energy required by the system, perfectly following the real load of the building, thanks to the modulation of the DC inverter fan. One single unit for the highest efficiency, sustainability and huge savings, thanks to the advantages of DC frequency driven fans and circulating pumps (inverter) for both plant and domestic hot water circuits. i-NRG is the new generation heat pump for all year round operation in any operating mode: single cycle (air conditioning, heating, domestic hot water) as well as combined cycle (domestic hot water together with heating or cooling). Domestic hot water production is guaranteed by the dedicated exchanger for heat recovery: total, for free domestic hot water production, or partial. Domestic hot water is stored in a properly dimensioned storage tank. The unit can be installed indoor or outdoor, thus ensuring complete flexibility. Commands Electronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoor temperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room and increasing the energy efficienty. The electronic board allows you to manage: - a zone of direct heating for radiator, floor heating or fan coil - zone with mix valve for floor heating - outdoor temperature sensor for water plant side modular set point compensation - electrical heating element for possible integration and anti-legionellosis cycle for cylinder - boiler in substitution or in additional - integration by solar panels with extension module (accessorie) - several solutions through appropriate configurations of the controller and use of dedicated extension modules (accessories) Structure and base in hot galvanised epoxy powder coated steel. Stainless steel (AISI 316) with high efficiency and low pressure drop plate to plate exchanger (at the domestic hot water side). It is positioned next after the compressor, it ensures the domestic hot water production. That can work either in full recovery or in part, with the constant optimization of efficiency through logic advanced adjusting controller Exchangers plant side plate of stainless steel AISI 316 with high efficiency and low pressure drop meets the supply of both hot or cold water for the facility, regardless of the domestic hot water DC inverter scroll compressor with self-adaptive capacity adjustment. Electronic expansion valve Finned coils made with copper pipes and aluminium fins with large exchange surface area (100% fully quality tested) Axial electric fan in continuous current housed in aerodynamic conveyor profile with safety grill. Low external air temperature device: continuous fan speed regulation with pressure switch The water circuit comes complete with: • Variable flow circulating pump in continuous current, plant side. • Variable flow circulating pump in continuous current, hot water side. • Expansion tank 10 lt. • Safety valve 3 bar. • Differential pressure swich plant side. • Pressure gauge. • Manual filling assembly. Main accessories • • • • • • • • • • • 48 Room terminal with temperature and humidity probe Expansion module for plant circuits additional Expansion module for solar thermal collector Buffer tank 35,100,200 liters Hot water cylinder 300,500 liters 300 litres thermal store for domestic hot water, for kit DOMH2O 300, 500, 1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump Removable metal mesh water filter kit Kit acoustic insulationg casing kit (mandatory for outdoor installation) KIt rectangular air ducts and grills for indoor installation i-NRG 0061m 0061t Nominal heating power (1) kW 16,3 16,3 Total absorbed power (2) kW 4,0 4,0 3,91 3,94 Models COP EN 14511 Cooling capacity (3) kW 19,6 19,7 Total absorbed power (2) kW 5,40 5,40 3,62 3,66 EER EN 14511 Total absorbed power (4) kW 17,9 18 Total absorbed power kW 4,9 4,9 Recovery heating capacity kW Compressor type N. Compressors N. Refrigerant N. fans N. Plant side pump type (5) Recovery side pump type (5) Electrical power supply V-Ph~Hz 22,6 22,6 SCROLL INVERTER DC SCROLL INVERTER DC 1 1 R410A R410A 1 1 i-Ci i-Ci i-Ci i-Ci 230-1~50 400-3N~50 Sound power (6) dB(A) 68 68 Sound pressure (7) dB(A) 52 52 DIMENSION L (8) mm 750 750 L (9) mm 1535 1535 H mm 1600 1600 P mm 1050 1050 kg 260 260 Operational weight NOTE (1) Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (2) Total input is obtained from compressor input and fan input. (3) Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s. (4) Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side) (5) i-Ci= Circolatore inverter corrente continua (6) Sound power level according to ISO 9614 and Eurovent 8/1 (7) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. (8) Indoor installation (9) Outdoor installation H P L (8) L (9) 49 PRANA AWR DHW 0021m÷0101ts Versioni AWR DHW AWR DHW - SL Air source reversible heat pump with domestic hot water supply with total heat recovery Air source reversible heat pump with domestic hot water supply with total heat recovery Features Reversible heat pump, total heat recovery, air source for outdoor installation 7,7 ÷ 33,5 kW Unit description PRANA DHW is the heat pump new generation able to operate throughout the year in any operating mode: either a single cycle (cooling, heating, hot water) and combined cycle (hot water along with air conditioning or heating). Energy efficiency is highest during the summer cycle, when, thanks to the full recovery of the heat, the production of hot water is free. During the combined use, the DHW exchanger uses the temperature of the discharge gases to gets inside the accumulation sanitary water as high as 65° C. The advanced electronic regulation developed by Climaveneta ensures the highest operational flexibility, fast working condition a significant increase in the overall COP, which go hand in hand with electricity and space reduction. Advantages, combined with the possibility of completely eliminating the traditional boiler, making heat pumps PRANA DHW the ideal solution for energy saving applications in residential, hotel and small sector. Commands AWR-DHW heats water stored in the tank as energy storage. It also comes with a state-of-the-art electronic unit, which independently controls the modes of operation. The appliance can operate throughout the year in any mode, both with single cycle (cooling, heating, hot water) and with combined cycle (hot water together with cooling or hot water together heating).During the summer cycle there is maximum energy saving through total heat recovery. This energy is completely free of charge with regard to the production of hot water. 50 Structure and base in hot galvanised epoxy powder coated steel. Stainless steel (AISI 316) with high efficiency and low pressure drop plate to plate exchanger (at the domestic hot water side). It is positioned next after the compressor, it ensures the domestic hot water production. That can work either in full recovery or in part, with the constant optimization of efficiency through logic advanced adjusting controller. Exchangers plant side plate of stainless steel AISI 316 with high efficiency and low pressure drop meets the supply of both hot or cold water for the facility, regardless of the domestic hot water Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection Finned coils made with copper pipes and aluminium fins with large exchange surface area (100% fully quality tested) Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal protection, housed in aerodynamic conveyor profile with safety grill Low external air temperature device: continuous fan speed regulation with pressure switch Coil protection grille Soft starter for 230V units /ms and 400V units /ts The water circuit comes complete with: • Variable flow circulator for 0021÷0025 models and multistage centrifugal variable flow pump for models 0041÷0101, plant side • Domestic hot water side water pump • Expansion tank • Safety valve • Manual filling assembly • Pressure gauge • Air vent valve Comando accessibile dallesterno con dispositivo antimanomissione Main accessories • Buffer tank 35,100,200 liters • Hot water cylinder 300,500 liters • 300 litres thermal store for domestic hot water, for kit DOMH2O • 300,500,1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O • DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump • Remote keyboard • Rubber anti-vibration mounting kit • Removable metal mesh water filter kit • Condensate collecting tray for models 0065÷0101 AWR DHW Models 0021m 0025m 0025t 0041t 0065t 0101t 0025ts 0041ts 0065ts Nominal heating power (1) kW 7,70 9,10 13 7,70 9,10 13 9,10 13 21,3 33,5 9,10 13 21,3 33,5 Total absorbed power (2) kW 2,30 2,70 3,70 2,30 2,70 3,70 2,70 3,70 5,60 8,50 2,70 3,70 5,60 8,50 * 3,35 3,37 3,51 3,35 3,37 3,51 3,37 3,51 3,80 3,94 3,37 3,51 3,80 3,94 Cooling capacity (3) kW 7,60 8,90 12,7 7,60 8,90 12,7 8,90 12,7 21,1 33 8,90 12,7 21,1 33 Total absorbed power (2) kW 2,40 2,70 3,80 2,40 2,70 3,80 2,70 3,80 5,80 9,40 2,70 3,80 5,80 9,40 * 3,17 3,30 3,34 3,17 3,30 3,34 3,30 3,34 3,64 3,51 3,30 3,34 3,64 3,51 (4) kW 7,40 8,50 11,8 7,40 8,50 11,8 8,40 11,9 18,2 33,1 8,40 11,9 18,2 33,1 Total absorbed power kW 2,30 2,70 4 2,30 2,70 4 2,60 4 6,10 9,40 2,60 4 6,10 9,40 Recovery heating capacity kW 9,60 11,0 15,5 9,60 11,0 15,5 10,9 15,6 23,9 42,0 10,9 15,6 23,9 42,0 COP EER Total absorbed power 0041m 0021ms 0025ms 0041ms 0101ts Heating capacity (5) kW 7,60 9 12,8 7,60 9 12,8 9,10 12,9 20,9 32,6 9,10 12,9 20,9 32,6 Total absorbed power (2) kW 2,90 3,40 4,60 2,90 3,40 4,60 3,40 4,60 7 10,3 3,40 4,60 7 10,3 * 2,66 2,68 2,78 2,66 2,68 2,78 2,68 2,81 2,99 3,17 2,68 2,81 2,99 3,17 Cooling capacity (6) kW 5,40 6,30 9,10 6,40 7,30 11,2 6,30 9,00 15,1 23,7 7,30 11,2 17 27,7 Total absorbed power (2) kW 2,40 2,70 3,70 2,40 2,70 3,80 2,70 3,60 5,40 9,00 2,70 3,80 5,90 9,50 * 2,25 2,33 2,46 2,25 2,33 2,46 2,33 2,50 2,80 2,63 2,33 2,50 2,80 2,63 COP EER Compressor type SCROLL N. Compressors N. 1 Refrigerant R407C N. fans N. Plant side pump type (7) Recovery side pump type (7) Electrical power supply V-Ph~Hz Corrente di spunto 2 2 2 2 2 2 2 2 1 2 2 2 1 2 Ci Ci Ce Ci Ci Ce Ci Ce Ce Ce Ci Ce Ce Ce Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 61 78 114 29 34 45 40 50 101 127 22 28 56 70 Sound power (8) dB(A) 68 69 70 68 69 70 69 70 76 77 69 70 76 77 Sound pressure (9) dB(A) 53 54 55 53 54 55 54 55 60 61 54 55 60 61 DIMENSION L mm 1125 1125 1250 1125 1125 1250 1125 1250 1700 1700 1125 1250 1700 1700 H mm 1125 1125 1125 1125 1125 1125 1125 1125 1200 1700 1125 1125 1200 1700 P mm 370 370 420 370 370 420 370 420 650 650 370 420 650 650 kg 144 144 168 144 144 168 144 168 295 378 144 168 295 378 Operational weight AWR DHW SL Models 0065t 0101t 0065ts Nominal heating power (1) kW 21,3 33,5 21,3 33,5 Total absorbed power (2) kW 5,60 8,50 5,60 8,50 * 3,80 3,94 3,80 3,94 Cooling capacity (3) kW 21,1 33 21,1 33 Total absorbed power (2) kW 5,80 9,40 5,80 9,40 * 3,64 3,51 3,64 3,51 (4) kW 18,2 33,1 18,2 33,1 kW 6,10 9,40 6,10 9,40 COP EER Total absorbed power Total absorbed power Recovery heating capacity 0101ts kW 23,9 42,0 23,9 42,0 Heating capacity (5) kW 21 32,9 21 32,9 Total absorbed power (2) kW 7,10 10,5 7,10 10,5 * 2,97 3,15 2,97 3,15 COP Cooling capacity (6) kW 15,2 23,9 15,2 23,9 Total absorbed power (2) kW 5,30 8,80 5,30 8,80 EER * Compressor type N. Compressors N. Refrigerant N. fans N. Plant side pump type (7) Recovery side pump type (7) Electrical power supply V-Ph~Hz Start-up current 2,87 2,72 2,87 2,72 SCROLL SCROLL SCROLL SCROLL 1 1 1 1 R407C R407C R407C R407C 2 3 2 3 Ce Ce Ce Ce Ci Ci Ci Ci 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 101 127 56 70 Sound power (8) dB(A) 73 74 73 74 Sound pressure (9) dB(A) 57 58 57 58 DIMENSION L mm 1700 1700 1700 1700 H mm 1200 1700 1200 1700 P mm 650 650 650 650 kg 295 378 295 378 Operational weight NOTE (1) Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (2) Total input is obtained from compressor input and fan input (3) Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s. (4) Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side) (5) Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (6) Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s. (7) Ci=Circolatore; Ce=Centrifuga (8) Sound power level according to ISO 9614 and Eurovent 8/1 (9) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. H * secondo Eurovent P L 51 PRANA AWR MTD1 0021ms÷0061t Versioni AWR MTD1 Medium temperature air source reversible heat pump for water heating up to 55°C Features Structure and base in hot galvanised epoxy powder coated steel. High efficiency and low pressure drop stainless steel (AISI 316) water exchangers complete with closed-cell insulation with vapour barrier,antifreeze heating element and differencial pressure switch Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection Finned coils made with copper pipes and aluminium fins with large exchange surface area (100% fully quality tested) Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal protection, housed in aerodynamic conveyor profile with safety grill Low external air temperature device: - continuous fan speed regulation with pressure switch Condensate collecting tray Coil protection grille Soft starter for 230V/1/50Hz units The water circuit comes complete with: • Variable flow circulator for all models • Water side differential pressure switch • Expansion tank • Safety valve • Manual filling assembly • Pressure gauge • Air vent valve Control with foolproof device accessible from the outside Reversible heat pump, air source for outdoor installation 6,9 ÷ 17,4 kW Main accessories Unit description Heat pumps AWR-MTD1 are reversible outdoor units with axial fans, hermetic scroll compressors and Full Floating technology. Full Floating is advanced electronics which has been developed by CLIMAVENETA in order to meet the needs of typical residential small size and small/medium tertiary sector, thanks to the accumulation. Another advantage that, together with the Hydraulic module components it make extremely simple the installation of heat pump: simply by connecting the unit to water plant and electricity so that it can be put into operation. Commands The new generation electronic controller allows to manage the heat pump by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: chiller operation even with larger operating limits, improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. The electronic menu allows to manage: - domestic hot water production by external three-way valve (accessory) - a zone of direct heating - outdoor temperature sensor for water plant side modular set point compensation - electrical heating element for possible integration and anti-legionellosis cycle for cylinder - boiler or electric heater management 52 • • • • • • • • • • • • Valvola deviatrice a 3 vie per produzione acqua calda sanitaria Disgiuntore idraulico da 35, 100, 200 litri Bollitore acqua calda sanitaria da 300, 500 litri Termoaccumulo per acqua calda sanitaria da 300 litri, da abbinare al kit preparatore istantaneo DOMH2O Termoaccumulo per acqua calda sanitaria da 300, 500 litri con serpentino solare, da abbinare al kit preparatore istantaneo DOMH2O Kit gestione caldaia in sostituzione Kit preparatore istantaneo acqua calda sanitaria DOMH2O15 e DOMH2O24 Kit resistenza elettrica da 1, 2, 3 kW Accumulo esterno e kit di collegamento idraulico Kit filtro acqua a rete metallica estraibile Supporti antivibranti in gomma Tastiera remota HSW11 AWR MTD1 Models 0021ms 0031ms 0041ms 0051ms 0041t 0051t Nominal heating power (1) kW 6,90 10,2 12,9 13,4 13 15,2 17,4 Total absorbed power (2) kW 1,70 2,60 3,40 3,20 3,50 3,90 4,10 * 3,95 3,94 3,82 4,14 3,77 3,88 4,27 Cooling capacity (3) kW 6,80 10,3 12,9 13,9 13,4 15,9 18,4 Total absorbed power (2) kW COP Eurovent EER Eurovent 0061t 2 3,40 4,10 4 4,20 4,60 5,40 * 3,40 2,98 3,06 3,37 3,20 3,25 3,38 17 Heating capacity (4) kW 6,80 10,1 12,7 13,1 13 14,6 Total absorbed power (2) kW 2,20 3,30 4,20 4 4,40 4,70 5 * 3,09 3,06 3,02 3,27 2,95 3,11 3,40 13,9 COP Eurovent Cooling capacity (5) kW 5,10 7,80 9,90 10,5 10,3 11,9 Total absorbed power (2) kW 2 3,30 3,90 3,80 4 4,50 5 2,55 2,36 2,54 2,76 2,58 2,64 2,78 3,15 2,98 3,06 3,37 3,20 3,25 3,38 EER Eurovent * ESEER Compressor type SCROLL N. Compressors N. 1 Refrigerant R410A N. fans Plant side pump type N. (6) Electrical power supply V-Ph~Hz Start-up current 1 1 2 2 2 2 2 Ci Ci Ci Ci Ci Ci Ci 400-3N~50 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 A 27 44 45 45 64 64 74 Sound power (7) dB(A) 66 66 69 69 69 69 69 Sound pressure (8) dB(A) 52 52 54 54 54 54 54 L mm 900 900 900 900 900 900 900 H mm 640 940 1240 1240 1240 1240 1390 P mm 370 370 370 370 370 370 420 kg 95 115 140 160 140 160 170 DIMENSION Operational weight NOTE (1) Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (2) Total input is obtained from compressor input and fan input (3) Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s. (4) Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (5) Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s. (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * H H L secondo Eurovent 53 P P L PRANA AWR MTD XE 0011ms÷0091t Versioni AWR MTD XE Medium temperature air source reversible heat pump for water heating up to 55°C and operating limits down to -15°C external air temperature AWR MTD XE/H Medium temperature air source reversible heat pump for water heating up to 55°C and operating limits down to -15°C external air temperature Features High efficiency reversible heat pump, air source for outdoor installation 6,3 ÷ 17,9 kW Unit description Heat pumps AWR-MTD-XE reversible units are able to provide heating, cooling and domestic hot water. Particular attention was paid to the winter, thanks to special technological devices is guaranteed beyond the normal limits of traditional units. Prana AWR-MTD-XE Air can be combined with traditional systems or radiant panels, ensuring a high energy efficiency. All units are certified in accordance with the Class A classification Eurovent energy in heating. This makes them particularly suitable for use radiant installations. The installation is greatly simplified through the integration of the group and hydraulic technology Full floating simply by connecting the unit to water plant and electricity so that it can be put into operation. Structure and base in hot galvanised epoxy powder coated steel. High efficiency and low pressure drop stainless steel (AISI 316) water exchangers complete with closed-cell insulation with vapour barrier,antifreeze heating element and differencial pressure switch Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection Finned coils made with copper pipes and aluminium fins with large exchange surface area (100% fully quality tested) Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal protection, housed in aerodynamic conveyor profile with safety grill Low external air temperature device: continuous fan speed regulation with pressure switch Electrical resistance modulating antifreeze to the base located between wing and base exchanger to improve and facilitate the flow of water during defrosting Condensate collecting tray Coil protection grille Soft starter for 230V/1/50Hz units Phase sequence control relay The water circuit comes complete with: • Variable flow circulator for all models • Water side differential pressure switch • Expansion tank • Safety valve • Manual filling assembly • Pressure gauge • Air vent valve Control with foolproof device accessible from the outside Main accessories • • • • • • • • Commands The new generation electronic controller allows to manage the heat pump by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: chiller operation even with larger operating limits, improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts. The electronic menu allows to manage: - domestic hot water production by external three-way valve (accessory) - a zone of direct heating - outdoor temperature sensor for water plant side modular set point compensation - electrical heating element for possible integration and anti-legionellosis cycle for cylinder - boiler or electric heater management 54 • • • • • Main accessories Three-way valve for domestic hot water Buffer tank 35,100,200 liters Hot water cylinder 300,500 liters 300 litres thermal store for domestic hot water, for kit DOMH2O 300,500 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O Kit boiler control DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump 1,2,3 kW single-phase electric heater kit External buffer tank and hydronic connecting kit Removable metal mesh water filter kit Rubber anti-vibration mounting kit HSW11 Remote keyboard AWR MTD XE Models 0011ms 0025ms 0031ms 0041ms 0031t 0041t 0051t 0061t 0091t Nominal heating power (1) kW 6,30 7,40 11,2 14 10,9 14 15,9 17,9 25,10 Total absorbed power (2) kW 1,50 1,80 2,60 3,30 2,60 3,30 3,80 4,20 6 * 4,20 4,11 4,31 4,24 4,19 4,24 4,18 4,26 4,18 COP Eurovent COP EN14511 4,13 4,15 4,22 4,16 4,15 4,15 4,11 4,25 4,19 Cooling capacity (3) kW 7,20 8,30 12,3 15,7 11,7 15,8 17,7 20,2 29,2 Total absorbed power (2) kW 1,90 2,20 3,30 4,10 3,10 4,20 4,70 5,30 7,80 * 3,79 3,77 3,73 3,83 3,77 3,76 3,77 3,81 3,74 3,82 3,82 3,81 3,84 3,84 3,81 3,81 3,81 3,85 EER Eurovent EER EN 14511 Heating capacity (4) kW 6,10 7,30 10,8 13,6 10,6 13,8 15,4 17,5 24,60 Total absorbed power (2) kW 1,90 2,30 3,30 4,10 3,20 4,30 4,60 5,20 7,40 * 3,21 3,17 3,27 3,32 3,31 3,21 3,35 3,37 3,32 COP Eurovent Cooling capacity (5) kW 5,20 6,30 9,20 11,7 8,60 11,9 13,2 15,2 22,10 Total absorbed power (2) kW 1,70 2,20 3,10 4,00 3,00 4,00 4,60 5,00 7,20 * 3,06 2,86 2,97 2,93 2,87 2,98 2,87 3,04 3,07 3,62 3,63 3,52 3,46 3,42 3,65 3,24 3,55 3,57 EER Eurovent ESEER Compressor type SCROLL N. Compressors N. 1 Refrigerant R410A N. fans Plant side pump type N. (6) Electrical power supply V-Ph~Hz Start-up current 1 1 2 2 2 2 2 2 3 Ci Ci Ci Ci Ci Ci Ci Ci Ci 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 27 30 45 45 48 64 64 75 111 Sound power (7) dB(A) 69 69 71 71 71 71 71 72 74 Sound pressure (8) dB(A) 54 54 56 56 56 56 56 57 58 DIMENSION L mm 900 900 900 900 900 900 900 1550 1550 H mm 1240 1240 1240 1390 1240 1390 1390 1200 1700 P mm 420 420 420 420 420 420 420 450 450 kg 145 150 155 170 155 170 180 250 335 Operational weight AWR MTD XE/H Models 0011ms 0025ms 0031ms 0041ms 0031t 0041t 0051t 0061t 0091t Nominal heating power (1) kW 6,30 7,40 11,2 14 10,9 14 15,9 17,9 25,10 Total absorbed power (2) kW 1,50 1,80 2,60 3,30 2,60 3,30 3,80 4,20 6 * 4,20 4,11 4,31 4,24 4,19 4,24 4,18 4,26 4,18 COP Eurovent COP EN14511 4,13 4,15 4,22 4,16 4,15 4,15 4,11 4,25 4,19 Cooling capacity (3) kW 7,20 8,30 12,3 15,7 11,7 15,8 17,7 20,2 29,2 Total absorbed power (2) kW 1,90 2,20 3,30 4,10 3,10 4,20 4,70 5,30 7,8 * 3,79 3,77 3,73 3,83 3,77 3,76 3,77 3,81 3,74 EER Eurovent EER EN 14511 3,82 3,82 3,81 3,84 3,84 3,81 3,81 3,81 3,85 Heating capacity (4) kW 6,10 7,30 10,8 13,6 10,6 13,8 15,4 17,5 24,6 Total absorbed power (2) kW 1,90 2,30 3,30 4,10 3,20 4,30 4,60 5,20 7,4 * 3,21 3,17 3,27 3,32 3,31 3,21 3,35 3,37 3,32 22,1 COP Eurovent Cooling capacity (5) kW 5,20 6,30 9,20 11,7 8,60 11,9 13,2 15,2 Total absorbed power (2) kW 1,70 2,20 3,10 4,00 3,00 4,00 4,60 5,00 7,2 * 3,06 2,86 2,97 2,93 2,87 2,98 2,87 3,04 3,07 3,62 3,63 3,52 3,46 3,42 3,65 3,24 3,55 3,57 EER Eurovent ESEER Compressor type SCROLL N. Compressors N. 1 Refrigerant R410A N. fans Plant side pump type N. (6) Electrical power supply V-Ph~Hz Start-up current 1 1 2 2 2 2 2 2 3 Ci Ci Ci Ci Ci Ci Ci Ci Ci 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 27 30 45 45 48 64 64 75 111 Sound power (7) dB(A) 69 69 71 71 71 71 71 72 74 Sound pressure (8) dB(A) 54 54 56 56 56 56 56 57 58 DIMENSION L mm 900 900 900 900 900 900 900 1550 1550 H mm 1240 1240 1240 1390 1240 1390 1390 1200 1700 P mm 420 420 420 420 420 420 420 450 450 kg 145 150 155 170 155 170 180 250 335 Operational weight NOTE (1) Water in-out 30/35°C (plant side), outdoor air temperatur 7°C b.s./ 6°C b.u. (2) Total input is obtained from compressor input and fan input. (3) Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s. (4) Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (5) Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s. (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * H H secondo Eurovent L 55 P P L PRANA AW HT 0031ms÷0071ts Versioni AW HT High temperature air source heat pump for water heating up to 65°C, and operating limits down to -20° external air temperature Features Structure and base in hot-dip galvanised steel with epoxy powder coating finish. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. High efficiency cycle EVI Hermetic Scroll Compressor (with hot gas direct injection into the compressor) to reach 65° C, with the crankcase heater and thermal protection Finned coils made with copper pipes and aluminium fins with large exchange surface area (100% fully quality tested); sub cooling circuit to prevent the icing at the basement A condense collecting tray within water discharge Coil protection grille Soft starter for 230V/1/50Hz units The water circuit comes complete with: • Circulating pump for all models • Expansion tank • Safety valve • Manual filling assembly • Pressure gauge • Air vent valve • Outside air sensor wired Heat pump, air source for outdoor installation, high water temperature 10,4 ÷ 19,7 kW Unit description AW HT is an ideal solution for systems with heating radiators, where the water high temperature is needed. The EVI technology compressor with additional steam injection in the compressing cycle assures a water temperature of 65°C and operating limits as low as -20°C. Neither probes nor connections pipes to wells are needed; the installation is simple, this is a suitable solution for all applications. Commands Electronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoor temperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room and increasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage: - domestic hot water production by external three-way valve (accessory) - circulator on system side - a zone of direct heating - outdoor temperature sensor for water plant side modular set point compensation - electrical heating element for possible integration and anti-legionellosis cycle for cylinder - integrated boiler with heat pump - several solutions through appropriate configurations of the controller and use of dedicated extension modules (accessories) Main accessories • • • • • • • • • • • • • • 56 Three-way valve for domestic hot water Buffer tank 35,100,200 liters Hot water cylinder 300,500 liters 300 litres thermal store for domestic hot water, for kit DOMH2O 300,500 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump Control kit for heat pump with boiler 1,2,3 kw single-phase electric heater kit Radiant panels or radiator management kit Second zone Control kit for underfloor heating with hydronic components Removable metal mesh water filter kit Rubber anti-vibration mounting kit Room unit wired Room thermostat wired based AW HT Models 0031ms 0041ms 0041t 0061t 0071t 0041ts 0061ts 0071ts Nominal heating power (1) kW 10,4 14,9 14,1 19,7 26,6 14,1 19,7 26,6 Total absorbed power (2) kW 2,50 3,50 3,30 4,70 6,1 3,30 4,70 6,1 4,10 4,12 4,14 4,12 4,26 4,14 4,12 4,26 27,1 COP EN14511 Heating capacity (3) kW 10,4 14,3 14,3 19,7 27,1 14,3 19,7 Total absorbed power (2) kW 3 4 4 5,60 7,4 4 5,60 7,4 3,30 4,48 3,48 3,45 3,58 3,48 3,45 3,58 23,5 COP EN14511 Heating capacity (4) kW 9,10 12,5 12,5 17,5 23,5 12,5 17,5 Total absorbed power (2) kW 2,50 3,30 3,30 4,60 5,9 3,30 4,60 5,9 3,44 3,66 3,66 3,72 3,88 3,66 3,72 3,88 COP EN 14511 Heating capacity (5) kW 7,80 11,4 11,4 14,8 21,2 11,4 14,8 21,2 Total absorbed power (2) kW 3,80 5,40 5,40 7,60 10,4 5,40 7,60 10,4 1,97 2,06 2,06 1,91 1,99 2,06 1,91 1,99 3 2 2 3 400-3N~50 COP EN 14511 Compressor type SCROLL EVI N. Compressors N. 1 Refrigerant R407C N. fans Plant side pump type N. 2 2 2 2 (6) Electrical power supply Ci V-Ph~Hz Start-up current 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 44 45 64 101 99 35 55 99 Sound power (7) dB(A) 70 70 70 71 74 70 71 74 Sound pressure (8) dB(A) 55 55 55 56 59 55 56 59 DIMENSION L mm 900 900 900 900 1470 900 900 1470 H mm 1240 1390 1390 1390 1700 1390 1390 1700 P mm 420 420 420 420 570 420 420 570 kg 150 160 160 170 320 160 170 320 Operational weight NOTE (1) Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (2) Total input is obtained from compressor input and fan input. (3) Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. (4) Water in-out 30/35°C (plant side), outdoor air temperature 2°C b.s./ 1°C b.u. (5) Water 65°C, outdoor air temperature -7°C b.s./ 1°C b.u. (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. H P L 57 PRANA WWR MTD 0011m÷0121t Versioni WWR MTD High temperature air source heat pump for water heating up to 65°C, and operating limits down to -20° external air temperature Features Structure and base in hot galvanised epoxy powder coated steel. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper. Soft starter for 230V/1/50Hz units /ms Phase sequence control relay The water circuit comes complete with: Variable flow circulator for 0011÷0031 models and multistage centrifugal variable flow pump for models 0071÷0121, plant side Modulating valve to reduce water consumptions, source side • Safety valve. • Expansion tank. • Manual filling assembly • Pressure gauge. • Air vent valve. • Drain valve on both plant and source circuits. • Differential pressure switch on source side and system side Reversible heat pump, water source 7,2 ÷ 43,8 kW Unit description The MTD water-cooled heat pump are reversible units for heating, cooling and domestic hot water by external three-way valve (accessory). Both heat pumps MTD are suitable for traditional heating systemsand radiant panels. The latter, working with water at lower temperatures, ensure a higher yield and are a particularly appreciated for new buildings with low energy consumption that point on using renewable energy resources. The installation is greatly simplified through the integration of the group and hydraulic technology Full floating simply by connecting the unit to water plant and electricity so that it can be put into operation. Commands User interface unit on board, accessible from the outside with a not touch system Floating Set Once ever y 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. He water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times. Floating Flow The controller manages the modulation of the active components (pump and electronic flow valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimised for different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broader operating limits; easier start-up of installations with both high and low water temperatures; faster system setup. The electronic menu allows to manage: - domestic hot water production by external three-way valve (accessory) - a zone of direct heating - circulator on system side and modulating valve - outdoor temperature sensor for water plant side modular set point compensation (accessory) 58 Main accessories • HSW12 remote keyboard • External temperature sensor (mandatory with HSW12 remote keyboard) • Three-way valve for domestic hot water • Buffer tank 35,100,200 liters • Hot water cylinder 300,500 liters • 300 litres thermal store for domestic hot water, for kit DOMH2O • 300,500,1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O • DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump • 1,2,3 kw single-phase electric heater kit WWR MTD Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER ESEER Compressor type N. Compressors Refrigerant Plant side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight (1) (2) (3) (2) (4) (2) (5) (2) kW kW * kW kW * kW kW * kW kW * 0011m 7,20 1,40 5,14 7,10 1,60 4,44 6,80 1,70 4 5,20 1,53 3,47 4,03 0021m 7,80 1,49 5,23 7,60 1,70 4,47 7,50 1,90 3,95 5,60 1,70 3,29 3,73 0025m 9,70 1,81 5,36 9,80 2 4,90 9,20 2,30 4 7,20 2 3,60 4,26 0031m 12,1 2,30 5,26 12 2,50 4,80 11,6 3 3,87 8,80 2,60 3,38 3,95 Ci Ci Ci Ci 58 52 38 61 52 38 82 53 39 97 53 39 N. (6) (7) (8) V-Ph~Hz A dB(A) dB(A) mm mm mm kg 0041m 0011ms 15,3 7,20 2,88 1,40 5,31 5,14 15,1 7,10 3,30 1,60 4,58 4,44 14,6 6,80 3,60 1,70 4,06 4 11,3 5,20 3,20 1,53 3,53 3,40 3,90 4,03 SCROLL 1 R410A Ci Ci 230-1~50 130 26 58 52 44 38 0021ms 7,80 1,49 5,23 7,60 1,70 4,47 7,50 1,90 3,95 5,60 1,70 3,29 3,73 0025ms 9,70 1,81 5,36 9,80 1,96 5 9,20 2,30 4 7,20 2 3,60 4,26 0031ms 12,1 2,30 5,26 12 2,53 4,74 11,6 3 3,87 8,80 2,60 3,38 3,95 0041ms 15,3 2,88 5,31 15,1 3,27 4,62 14,6 3,60 4,06 11,3 3,20 3,53 3,90 Ci Ci Ci Ci 27 52 38 37 53 39 44 53 39 59 58 44 148 150 152 160 0071t 26,2 4,60 5,70 26,9 5,20 5,17 24,8 5,80 4,28 19,8 5,10 3,88 4,40 0091t 30,5 5,20 5,87 30,7 6 5,12 28,8 6,40 4,50 22,9 5,80 3,95 4,61 0101t 35 6 5,83 34,8 7 4,97 33 7,60 4,34 26 6,80 3,82 4,33 0121t 43,8 7,60 5,76 44,8 8,80 5,09 41,7 9,50 4,39 33,4 8,39 3,98 4,37 Ce Ce Ce Ce 95 66 51 111 66 51 118 70 55 140 70 55 680 1150 780 220 680 1150 780 230 680 1150 780 235 680 1150 780 250 L P 560 980 575 148 148 150 152 0021t 7,80 1,40 5,57 7,60 1,60 4,75 7,40 1,90 3,89 5,60 1,60 3,50 3,97 0025t 9,80 1,73 5,66 9,50 1,80 5,28 9,20 2,20 4,18 7,30 1,90 3,84 4,54 0031t 12,1 2,17 5,58 12 2,50 4,80 11,4 2,70 4,22 8,90 2,40 3,71 4,33 0041t 15,9 2,90 5,48 15,7 3,30 4,76 15,3 3,70 4,14 11,8 3,20 3,70 4,08 160 148 WWR MTD Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER ESEER Compressor type N. Compressors Refrigerant Plant side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight (1) (2) (3) (2) (4) (2) (5) (2) kW kW * kW kW * kW kW * kW kW * N. (6) (7) (8) Ci Ci Ci Ci V-Ph~Hz A dB(A) dB(A) 32 52 38 35 52 38 48 52 38 64 58 44 mm mm mm kg 560 980 575 148 560 980 575 150 560 980 575 152 560 980 575 160 0051t 0061t 18,1 21,1 3,40 3,70 5,32 5,70 18 21,3 3,80 4,10 4,74 5,20 17,1 20 4,20 4,60 4,07 4,35 13,2 15,7 3,80 4 3,47 3,93 3,92 4,51 SCROLL 1 R410A Ci Ci 400-3N~50 64 75 58 59 44 45 560 980 575 170 NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side) (2) Total input is obtained from compressor input and fan input. (3) Temperatura acqua impianto 23/18°C, temperatura acqua sorgente 30/35°C (4) Temperatura acqua impianto 40/45°C, temperatura acqua sorgente ingresso 10°C (5) Temperatura acqua impianto 12/7°C, temperatura acqua sorgente 30/35°C (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * secondo Eurovent 59 560 980 575 175 H PRANA WWR HT Slim Z1M6÷Z1T11 Versioni WWR HT Slim High temperature heat pump, water source for water heating up to 60°C, reversible Features Reversible heat pump, water source, high water temperature with buffer tank 8,3 ÷ 14,1 kW Unit description The Prana Slim heat pump is designed for heating, cooling, and domestic hot water. It is an indoor unit with elegant design and thanks to a special sound insulation, the unit is suitable for a living comfort. Commands Electronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoor temperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room and increasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage: - domestic hot water production by three-way valve - circulator on system side - a zone of direct heating - zone with mix valve for floor heating - outdoor temperature sensor for water plant side modular set point compensation - integration by solar panels - several solutions through appropriate configurations of the controller 60 Structure and base in hot galvanised epoxy powder coated steel. 180-litre tank with built-in coil for domestic hot water, with fittings for connecting solar panels or hightemperature fixtures (e.g. fan coils) High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. High-efficiency single-and three-phase SCROLL compressor to allow water up to 60 °C to be produced. Also suitable for traditional radiator systems. The compressor and plate heat exchangers are housed in a suitably insulated enclosure to limit vibrations and noise. This enclosure can be removed from the unit to make maintenance easier Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper. Soft starter for 230V/1/50Hz units Phase sequence control relay The water circuit comes complete with: • Circulator on system side • Three-way valve for domestic hot water • Safety valve • 180Xlt domestic hot water storage tank • Expansion tank built into the heat pumps tank • Manual filling assembly • Pressure gauge • Air vent valve • Drain valve • Differential pressure switch on source side and system side • Outside air sensor wired Main accessories • • • • • • Room unit wired Room thermostat wired based Room unit wireless Outside air sensor wireless NTC probe for select plant diagram or solar panel Heating element kit WWR HT Slim Models Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Nominal heating power (1) kW 8,30 11,6 14,1 8,20 11,4 14 Total absorbed power (2) kW 1,60 2,22 2,68 1,56 2,14 2,61 * 5,19 5,23 5,26 5,24 5,34 5,35 Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6 Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64 * 6,54 6,25 5,71 6,46 6,27 5,92 COP EER Z1T11 Heating capacity (4) kW 7,95 11,1 13,6 7,87 11 13,5 Total absorbed power (2) kW 2,02 2,80 3,37 1,98 2,72 3,27 * 3,94 3,96 4,02 3,97 4,04 4,11 Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1 Total absorbed power (2) COP kW 1,53 2,17 2,67 1,49 2,09 2,59 EER * 4,36 4,26 4,16 4,42 4,36 4,28 Hot water tank l 180 Compressor type SCROLL N. Compressors N. 1 Refrigerant Plant side pump type R407C (6) Electrical power supply V-Ph~Hz Start-up current Ci Ci Ci Ci Ci Ci 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 A 37 60 68 32 46 50 Sound power (7) dB(A) 42 42 46 42 42 46 Sound pressure (8) dB(A) 28 28 32 28 28 32 286 293 300 DIMENSION L mm 600 H mm 1940 P mm Operational weight kg 570 286 293 300 NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side) with identical flow rate that in the cooling mode (2) According to Eurovent (3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side) (4) Condenser water in-out 40/45°C (plant side), water in 10°C (source side) with identical flow rate that in the cooling mode (5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side) (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * H P secondo Eurovent L 61 PRANA WWR HT Cube Z1M6÷Z1T28 Versioni WWR HT Cube High temperature heat pump, water source for water heating up to 60°C, reversible Features Structure and base in hot galvanised epoxy powder coated steel. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. High-efficiency single-and three-phase SCROLL compressor to allow water up to 60 °C to be produced. Also suitable for traditional radiator systems. The compressor and plate heat exchangers are housed in a suitably insulated enclosure to limit vibrations and noise. This enclosure can be removed from the unit to make maintenance easier Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper. Soft starter for 230V/1/50Hz units Phase sequence control relay The water circuit comes complete with: • Circulator on system side • Drain valve • Differential pressure switch on source side and system side • Outside air sensor wired Main accessories Reversible heat pump, water source, high water temperature 8,3 ÷ 35,9 kW Unit description The Prana Cube heat pump is designed for heating, cooling, and domestic hot water, with external three-way valve. It is an indoor unit with elegant design and thanks to a special sound insulation, the unit is suitable for a living comfort. Commands Electronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoor temperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room and increasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage: - domestic hot water production by external three-way valve (accessory) - circulator on system side - a zone of direct heating - zone with mix valve for floor heating - outdoor temperature sensor for water plant side modular set point compensation - integration by solar panels - several solutions through appropriate configurations of the controller 62 • • • • • • • • • • Room unit wired Room thermostat wired based Room unit wireless Outside air sensor wireless NTC probe for select plant diagram or solar panel Heating element kit Three-way valve for domestic hot water Buffer tank 35,100,200 liters Hot water cylinder 300,500 liters 300 litres thermal store for domestic hot water, for kit DOMH2O • 300,500,1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O • DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump WWR HT Cube Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Z1T11 Z1T13 Z1T17 Z1T24 Nominal heating power (1) kW 8,30 11,6 14,1 8,20 11,4 14 17,1 22,6 31,1 35,9 Total absorbed power (2) kW 1,60 2,22 2,68 1,56 2,14 2,61 3,28 4,30 5,84 6,59 * 5,19 5,23 5,26 5,24 5,34 5,35 5,22 5,27 5,33 5,45 Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6 19 24,9 34,7 40 Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64 3,76 4,95 6,14 7 * 6,54 6,25 5,71 6,46 6,27 5,92 5,04 5,02 5,65 5,71 34,5 Models COP EER Z1T28 Heating capacity (4) kW 7,95 11,1 13,6 7,87 11 13,5 16,4 21,8 29,9 Total absorbed power (2) kW 2,02 2,80 3,37 1,98 2,72 3,27 4,07 5,39 7,28 8,29 * 3,94 3,96 4,02 3,97 4,04 4,11 4,02 4,04 4,11 4,16 28,2 COP Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1 13,4 17,5 24,3 Total absorbed power (2) kW 1,53 2,17 2,67 1,49 2,09 2,59 3,38 4,53 6,01 6,77 * 4,36 4,26 4,16 4,42 4,36 4,28 3,97 3,87 4,05 4,16 Ci Ci Ci Ci EER Compressor type SCROLL N. Compressors N. 1 Refrigerant Plant side pump type R407C (6) Electrical power supply Ci V-Ph~Hz Start-up current Ci 230-1~50 230-1~50 Ci Ci Ci Ci 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 37 60 68 32 46 50 66 101 123 127 Sound power (7) dB(A) 42 42 46 42 42 46 47 51 55 55 Sound pressure (8) dB(A) 28 28 32 28 28 32 33 37 41 41 L mm 600 600 600 600 600 600 600 600 900 900 H mm 940 940 940 940 940 940 940 940 1117 1117 P mm 570 570 570 570 570 570 570 570 648 648 kg 160 180 190 160 180 190 200 220 240 250 DIMENSION Operational weight NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side) with identical flow rate that in the cooling mode (2) According to Eurovent (3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side) (4) Condenser water in-out 40/45°C (plant side), water in 10°C (source side) with identical flow rate that in the cooling mode (5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side) (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * H P L secondo Eurovent 63 PRANA WWR DHW 0011m÷0121t Versioni WWR MTD Water source reversible heat pump with domestic hot water supply with total heat recovery Features Reversible heat pump, total heat recovery, water source 6,0 ÷ 40,5 kW Unit description PRANA DHW is the heat pump new generation able to operate throughout the year in any operating mode: either a single cycle (air conditioning, heating, hot water) and combined cycle (hot water along with air conditioning or heating). Energy efficiency is highest during the summer cycle, when, thanks to the full recovery of the heat, the production of hot water is free. During the combined use, the DHW exchanger uses the temperature of the hot exhaust gases to gets inside the accumulation sanitary water as high as 65° C. The advanced CLIMAVENETA fully patented electronic ensures the highest flexibility of operation, a rapid speed and a significant increase in the overall COP, which go hand in hand with electricity and space reduction. Advantages, combined with the possibility of completely eliminating the traditional boiler, making heat pumps PRANA DHW the ideal solution for energy saving applications in residential, hotel and small sector. Commands User interface unit on board, accessible from the outside with a not touch system WWR-DHW heats water stored in the tank as energy storage. It also comes with a state-of-the-art electronic unit, which independently controls the modes of operation. The appliance can operate throughout the year in any mode, both with single cycle (cooling, heating, hot water) and with combined cycle (hot water together with cooling or hot water together heating).During the summer cycle there is maximum energy saving through total heat recovery. This energy is completely free of charge with regard to the production of hot water. 64 Structure and base in hot galvanised epoxy powder coated steel Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection Stainless steel (AISI 316) with high efficiency and low pressure drop plate to plate exchanger (at the domestic hot water side). It is positioned next after the compressor, it ensures the domestic hot water production. That can work either in full recovery or in part, with the constant optimization of efficiency through logic advanced adjusting controller Exchangers plant side plate of stainless steel AISI 316 with high efficiency and low pressure drop meets the supply of both hot or cold water for the facility, regardless of the domestic hot water High efficiency and low pressure drop stainless steel (AISI 316) source side plate exchanger Soft starter for 230V/1/50Hz units /ms The water circuit comes complete with: • Variable flow circulator for 0011÷0031 models and multistage centrifugal variable flow pump for models 0071÷0121, plant side • Domestic hot water, water side, variable flow pump • Modulating valve to reduce water consumptions, source side • Safety valve • Expansion tank • Drain valve on both plant and source circuits Main accessories • Buffer tank 35,100,200 liters • Hot water cylinder 300,500 liters • 300 litres thermal store for domestic hot water, for kit DOMH2O • 300,500,1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O • DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump • Remote keyboard • Removable metal mesh water filter kit WWR DHW Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Total absorbed power Total absorbed power Recovery heating capacity Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER Compressor type N. Compressors Refrigerant Plant side pump type Recovery side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Total absorbed power Total absorbed power Recovery heating capacity Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER Compressor type N. Compressors Refrigerant Plant side pump type Recovery side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight 0011m 6 1,30 4,49 7,30 1,30 5,62 6 1,90 7,90 5,70 1,70 3,33 5,10 1,30 3,92 0021m 7,60 1,70 4,48 9,20 1,70 5,41 7,80 2,40 10 7,30 2,20 3,35 6,50 1,70 3,82 Ci Ci 230-1~50 47 52 38 Ci Ci 230-1~50 61 52 38 560 980 575 188 560 980 575 188 560 980 575 190 560 980 575 195 0021t 7,50 1,70 4,55 9,20 1,60 5,75 7,70 2,30 9,90 7,20 2,10 3,41 6,50 1,70 3,82 0025t 8,90 2 4,58 10,9 1,90 5,74 9,10 2,80 11,7 8,60 2,50 3,42 7,70 2 3,85 0031t 10,3 2,30 4,44 12,4 2,30 5,39 10,3 3,30 13,4 9,90 3 3,34 8,80 2,30 3,83 0041t 12,7 2,80 4,57 15,4 2,80 5,50 13,1 4 16,9 12,3 3,50 3,48 10,9 2,80 3,89 Ci Ci Ci Ci Ci Ci Ci Ci V-Ph~Hz A dB(A) dB(A) 32 52 38 40 52 38 46 52 38 50 58 44 mm mm mm kg 560 980 575 188 560 980 575 190 560 980 575 195 560 980 575 215 (1) (2) kW kW (3) (2) kW kW (4) (4) (5) (2) kW kW kW kW kW (6) (2) kW kW 0025m 9 2 4,51 11 2 5,50 9,20 2,90 11,9 8,70 2,60 3,37 7,70 2 3,85 0031m 10,5 2,40 4,36 12,5 2,40 5,21 10,3 3,40 13,5 10,1 3,10 3,28 8,90 2,40 3,71 N. (7) (7) (8) (9) V-Ph~Hz A dB(A) dB(A) mm mm mm kg (1) (2) kW kW (3) (2) kW kW (4) (4) (5) (2) kW kW kW kW kW (6) (2) kW kW Ci Ci Ci Ci 230-1~50 230-1~50 76 100 53 53 39 39 N. (7) (7) (8) (9) 0041m 0011ms 12,9 6 2,90 1,30 4,50 4,49 15,3 7,30 2,90 1,30 5,28 5,62 12,9 6 4,20 1,90 16,8 7,90 12,4 5,60 3,60 1,70 3,40 3,33 11 5,10 2,90 1,30 3,79 3,92 SCROLL 1 R407C Ci Ci Ci Ci 230-1~50 230-1~50 114 21 58 52 44 38 560 980 575 215 560 980 575 188 0051t 0061t 15,6 18,7 3,40 3,90 4,58 4,75 19,1 22,5 3,60 4,10 5,31 5,49 16 18,9 4,90 5,70 20,6 24,2 14,9 17,9 4,30 4,90 3,50 3,62 13,4 16,1 3,40 4 3,94 4,03 SCROLL 1 R407C Ci Ce Ci Ci 400-3N~50 66 74 58 59 44 45 560 980 575 228 560 980 575 233 NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side) with identical flow rate that in the cooling mode (2) According to Eurovent (3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side) (4) Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side) (5) Condenser water in-out 40/45°C (plant side), water in 10°C (source side) with identical flow rate that in the cooling mode (6) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side) (7) Ci=Circulator; Ce=Centrifugal (8) Sound power level according to ISO 9614 and Eurovent 8/1 (9) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. 65 0021ms 7,60 1,70 4,48 9,20 1,70 5,41 7,80 2,40 10 7,20 2,20 3,35 6,50 1,70 3,82 0025ms 9 2 4,51 11 2 5,50 9,20 2,90 11,9 8,50 2,60 3,37 7,70 2 3,85 0031ms 10,5 2,40 4,36 12,5 2,40 5,21 10,3 3,40 13,5 9,90 3,10 3,28 8,90 2,40 3,71 0041ms 12,9 2,90 4,50 15,3 2,90 5,28 12,9 4,20 16,8 12,2 3,60 3,40 11 2,90 3,79 Ci Ci 230-1~50 27 52 38 Ci Ci 230-1~50 34 53 39 Ci Ci 230-1~50 45 53 39 Ci Ci 230-1~50 51 58 44 560 980 575 188 560 980 575 190 560 980 575 195 560 980 575 215 0071t 25,3 5,30 4,73 30,2 5,50 5,49 25,5 7,70 32,7 24 6,80 3,55 21,7 5,40 4,02 0091t 28,4 5,90 4,84 34,4 6,10 5,64 29 8,40 36,9 27,1 7,30 3,69 24,6 5,90 4,17 0101t 32,6 6,90 4,69 38,9 7,30 5,33 32,7 10,2 42,4 31,1 8,70 3,55 28 7 4,00 0121t 40,5 8,80 4,59 49,7 9,30 5,34 41,1 12,8 53,1 38,3 11,1 3,45 34,8 8,90 3,91 Ce Ci Ce Ci Ce Ci Ce Ci 95 66 51 111 66 51 118 70 55 140 70 55 680 1150 780 260 680 1150 780 270 680 1150 780 280 680 1150 780 305 L P H PRANA BWR MTD 0011m÷0121t Versioni BWR MTD Medium temperature geothermal reversible heat pump for water heating up to 55°C Features Reversible heat pump, geothermal source 5,4 ÷ 33,3 kW Unit description The MTD heat pump optimized for geothermal systems are reversible units for heating, cooling and domestic hot water by external three-way valve (accessory). Both heat pumps MTD are suitable for traditional heating systemsand radiant panels. The latter, working with water at lower temperatures, ensure a higher yield and are a particularly appreciated for new buildings with low energy consumption that point on using renewable energy resources. The installation is greatly simplified through the integration of the group and hydraulic technology Full floating simply by connecting the unit to water plant and electricity so that it can be put into operation. Commands User interface unit on board, accessible from the outside with a not touch system Floating Set Once ever y 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. he water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times. Floating Flow The controller manages the modulation of the active components (pump and electronic flow valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimised for different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broader operating limits; easier start-up of installations with both high and low water temperatures; faster system setup. The electronic menu allows to manage: - domestic hot water production by external three-way valve (accessory) - a zone of direct heating - circulator on system and source side - outdoor temperature sensor for water plant side modular set point compensation (accessory) 66 Structure and base in hot galvanised epoxy powder coated steel. High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection. Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper. Soft starter for 230V/1/50Hz units /ms Phase sequence control relay The water circuit comes complete with: • Variable flow circulator for 0011÷0031 models and multistage centrifugal variable flow pump for models 0071÷0121, plant side • Variable flow circulator for 0011÷0031 models, multistage centrifugal variable flow pump for models 0071-0121 on source side (for geothermal systems, closed vertical or horizontal loops) • Safety valve. • Expansion tank. • Manual filling assembly • Pressure gauge. • Air vent valve. • Drain valve on both plant and source circuits. • Differential pressure switch on source side and system side Main accessories • HSW12 remote keyboard • External temperature sensor (mandatory with HSW12 remote keyboard) • Three-way valve for domestic hot water • Buffer tank 35,100,200 liters • Hot water cylinder 300,500 liters • 300 litres thermal store for domestic hot water, for kit DOMH2O • 300,500,1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O • DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump • 1,2,3 kw single-phase electric heater kit BWR MTD Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER ESEER Compressor type N. Compressors Refrigerant Plant side pump type Source side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER ESEER Compressor type N. Compressors Refrigerant Plant side pump type Source side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight (1) (2) (3) (2) (4) (2) (5) (2) kW kW * kW kW * kW kW * kW kW * 0011m 5,40 1,34 4,03 7,10 1,60 4,44 5,20 1,70 3,06 5,20 1,53 3,40 4,03 0021m 5,90 1,50 3,93 7,60 1,70 4,47 5,70 1,90 3 5,60 1,70 3,29 3,73 0025m 7,30 1,82 4 9,80 1,96 5 7,10 2,30 3,09 7,20 2 3,60 4,26 0031m 9,20 2,35 3,92 12 2,53 4,74 9 3 3 8,80 2,60 3,38 3,95 Ci Ci Ci Ci Ci Ci Ci Ci 58 52 38 61 52 38 82 53 39 97 53 39 N. (6) (6) (7) (8) V-Ph~Hz A dB(A) dB(A) mm mm mm kg (1) (2) (3) (2) (4) (2) (5) (2) 148 150 152 0021t 5,90 1,40 4,21 7,60 1,60 4,75 5,70 1,90 3 5,60 1,63 3,44 3,97 0025t 7,50 1,74 4,31 9,50 1,84 5,16 7 2,20 3,18 7,30 1,90 3,84 4,54 0031t 9,10 2,10 4,33 12 2,50 4,80 8,70 2,70 3,22 8,90 2,41 3,69 4,33 0041t 12,2 2,80 4,36 15,7 3,30 4,76 11,8 3,70 3,19 11,8 3,19 3,70 4,08 Ci Ci Ci Ci Ci Ci Ci Ce V-Ph~Hz A dB(A) dB(A) 32 52 38 35 52 38 48 52 38 64 58 44 mm mm mm kg 560 980 575 148 560 980 575 150 560 980 575 152 560 980 575 160 N. (6) (6) (7) (8) 160 secondo Eurovent 67 148 0051t 0061t 13,7 16 3,40 3,50 4,03 4,57 18 21,3 3,70 4,10 4,86 5,20 12,9 15,2 4,10 4,40 3,15 3,45 13,2 15,7 3,80 4 3,47 3,93 3,92 4,51 SCROLL 1 R410A Ci Ci Ce Ce 400-3N~50 64 75 58 59 44 45 560 980 575 170 NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side) (2) According to Eurovent (3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side) (4) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side) (5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side) (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * 0021ms 5,90 1,50 3,93 7,60 1,70 4,47 5,70 1,90 3 5,60 1,70 3,29 3,73 0025ms 7,30 1,82 4 9,80 1,96 5 7,10 2,30 3,09 7,20 2 3,60 4,26 0031ms 9,20 2,35 3,92 12 2,53 4,74 9 3 3 8,80 2,60 3,38 3,95 0041ms 11,7 2,80 4,18 15,1 3,27 4,62 11,3 3,60 3,14 11,3 3,20 3,53 3,90 Ci Ci Ci Ci Ci Ci Ci Ce 27 52 38 37 53 39 44 53 39 59 58 44 148 150 152 160 0071t 19,8 4,40 4,50 26,9 5,15 5,22 18,8 5,60 3,36 19,8 5,10 3,88 4,40 0091t 23 4,90 4,69 30,7 5,95 5,16 21,8 6,20 3,52 22,9 5,80 3,95 4,61 0101t 26,5 5,80 4,57 34,8 7 4,97 25,1 7,40 3,39 26 6,80 3,82 4,33 0121t 33,3 7,30 4,56 44,8 8,80 5,09 31,9 9 3,54 33,4 8,40 3,98 4,37 Ce Ce Ce Ce Ce Ce Ce Ce 95 66 51 111 66 51 118 70 55 140 70 55 680 1150 780 220 680 1150 780 230 680 1150 780 235 680 1150 780 250 L P 560 980 575 148 kW kW * kW kW * kW kW * kW kW * 0041m 0011ms 11,7 5,40 2,80 1,34 4,18 4,03 15,1 7,10 3,27 1,60 4,62 4,44 11,3 5,20 3,60 1,70 3,14 3,06 11,3 5,20 3,20 1,53 3,53 3,40 3,90 4,03 SCROLL 1 R410A Ci Ci Ce Ci 230-1~50 130 26 58 52 44 38 560 980 575 175 H PRANA BWR HT Slim Z1M6÷Z1T11 Versioni BWR HT Slim High temperature heat pump, geothermal source, for water heating up to 60°C, reversible Features Reversible heat pump, geothermal source, high water temperature with buffer tank 6,2 ÷ 10,6 kW Unit description The Prana Slim heat pump is designed for heating, cooling, and domestic hot water. It is an indoor unit with elegant design and thanks to a special sound insulation, the unit is suitable for a living comfort. Commands Electronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoor temperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room and increasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage: - domestic hot water production by three-way valve - circulator on system and source side - a zone of direct heating - zone with mix valve for floor heating - outdoor temperature sensor for water plant side modular set point compensation - integration by solar panels - several solutions through appropriate configurations of the controller 68 Structure and base in hot galvanised epoxy powder coated steel 180-litre tank with built-in coil for domestic hot water, with fittings for connecting solar panels or hightemperature fixtures (e.g. fan coils) High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection High-efficiency single-and three-phase SCROLL compressor to allow water up to 60 °C to be produced Also suitable for traditional radiator systems The compressor and plate heat exchangers are housed in a suitably insulated enclosure to limit vibrations and noise. This enclosure can be removed from the unit to make maintenance easier Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper Soft starter for 230V/1/50Hz units Phase sequence control relay The water circuit comes complete with: • Circulator on system side • Circulator on source side (for geothermal systems, closed vertical or horizontal loops) • Three-way valve for domestic hot water • 180Xlt domestic hot water storage tank • Safety valve • Expansion tank built into the heat pumps tank • Manual filling assembly • Pressure gauge • Drain valve • Air vent valve • Differential pressure switch on source side and system side • Outside air sensor wired Main accessories • • • • • • Room unit wired Room thermostat wired based Room unit wireless Outside air sensor wireless NTC probe for select plant diagram or solar panel Heating element kit BWR HT Slim Models Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Nominal heating power (1) kW 6,21 8,66 10,6 6,04 8,43 10,5 Total absorbed power (2) kW 1,60 2,22 2,68 1,55 2,13 2,60 * 3,88 3,90 3,96 3,90 3,96 4,02 Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6 Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64 * 6,54 6,25 5,71 6,46 6,27 5,92 COP EER Z1T11 Heating capacity (4) kW 6,04 8,41 10,3 5,89 8,20 10,2 Total absorbed power (2) kW 2,02 2,80 3,35 1,97 2,71 3,24 * 2,99 3 3,08 2,99 3,03 3,14 COP Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1 Total absorbed power (2) kW 1,53 2,17 2,67 1,49 2,09 2,59 EER * 4,36 4,26 4,16 4,42 4,36 4,28 Hot water tank l Ci 180 Compressor type N. Compressors SCROLL N. 1 Refrigerant R407C Plant side pump type (6) Ci Ci Ci Ci Ci Source side pump type (6) Ci Ci Ci Ci Ci Ci 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 Electrical power supply V-Ph~Hz Start-up current A 37 60 68 32 46 50 Sound power (7) dB(A) 42 42 46 42 42 46 Sound pressure (8) dB(A) 28 28 32 28 28 32 286 293 300 DIMENSION L mm 600 H mm 1940 P mm Operational weight kg 570 286 293 300 NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side) (2) According to Eurovent (3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side) (4) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side) (5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side) (6) Ci=Circulator; Ce=Centrifugal (7) Sound power level according to ISO 9614 and Eurovent 8/1 (8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * H secondo Eurovent P L 69 PRANA BWR HT Cube Z1M6÷Z1T28 Versioni BWR HT Cube High temperature heat pump, geothermal source, for water heating up to 60°C, reversible Features Structure and base in hot galvanised epoxy powder coated steel High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection High-efficiency single-and three-phase SCROLL compressor to allow water up to 60 °C to be produced Also suitable for traditional radiator systems The compressor and plate heat exchangers are housed in a suitably insulated enclosure to limit vibrations and noise. This enclosure can be removed from the unit to make maintenance easier Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper Soft starter for 230V/1/50Hz units Phase sequence control relay The water circuit comes complete with: • Circulator on system side • Circulator on source side (for geothermal systems, closed vertical or horizontal loops) • Drain valve • Differential pressure switch on source side and system side • Outside air sensor wired Reversible heat pump, geothermal source, high water temperature 6,2 ÷ 27,0 kW Unit description The Prana Cube heat pump is designed for heating, cooling, and domestic hot water, with external three-way valve. It is an indoor unit with elegant design and thanks to a special sound insulation, the unit is suitable for a living comfort. Commands Electronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoor temperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room and increasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage: - domestic hot water production by three-way valve - circulator on system and source side - a zone of direct heating - zone with mix valve for floor heating - outdoor temperature sensor for water plant side modular set point compensation - integration by solar panels - several solutions through appropriate configurations of the controller 70 Main accessories • • • • • • • • • • Room unit wired Room thermostat wired based Room unit wireless Outside air sensor wireless NTC probe for select plant diagram or solar panel Heating element kit Three-way valve for domestic hot water Buffer tank 35,100,200 liters Hot water cylinder 300,500 liters 300 litres thermal store for domestic hot water, for kit DOMH2O • 300,500,1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O • DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump BWR HT Cube Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Z1T11 Z1T13 Z1T17 Z1T24 Nominal heating power (1) kW 6,21 8,66 10,6 6,04 8,43 10,5 12,6 16,9 23,3 27 Total absorbed power (2) kW 1,60 2,22 2,68 1,55 2,13 2,60 3,17 4,14 5,74 6,53 * 3,88 3,90 3,96 3,90 3,96 4,02 3,96 4,09 4,06 4,14 Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6 19 24,9 34,7 40 Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64 3,76 4,95 6,14 7 * 6,54 6,25 5,71 6,46 6,27 5,92 5,04 5,02 5,65 5,71 26,2 Models COP EER Z1T28 Heating capacity (4) kW 6,04 8,41 10,3 5,89 8,20 10,2 12,2 16,4 22,6 Total absorbed power (2) kW 2,02 2,80 3,35 1,97 2,71 3,24 3,94 5,24 7,12 8,12 * 2,99 3 3,08 2,99 3,03 3,14 3,09 3,14 3,18 3,23 28,2 COP Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1 13,4 17,5 24,3 Total absorbed power (2) kW 1,53 2,17 2,67 1,49 2,09 2,59 3,38 4,53 6,01 6,77 * 4,36 4,26 4,16 4,42 4,36 4,28 3,97 3,87 4,05 4,16 EER Compressor type SCROLL N. Compressors N. 1 Refrigerant R407C Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Source side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Electrical power supply V-Ph~Hz Start-up current 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 37 60 68 32 46 50 66 101 123 127 Sound power (7) dB(A) 42 42 46 42 42 46 47 51 55 55 Sound pressure (8) dB(A) 28 28 32 28 28 32 33 37 41 41 L mm 600 600 600 600 600 600 600 600 900 900 H mm 940 940 940 940 940 940 940 940 1117 1117 P mm 570 570 570 570 570 570 570 570 648 648 kg 160 180 190 160 180 190 200 220 240 250 DIMENSION Operational weight NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side) (2) According to Eurovent (3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side) (4) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side) (5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side) (6) Ci=Circulator; Ce=Centrifugal (8) Sound power level according to ISO 9614 and Eurovent 8/1 (9) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. * secondo Eurovent H P L 71 PRANA BWR DHW 0011m÷0121t Versioni BWR DHW Geothermal reversible heat pump with domestic hot water supply with total heat recovery Features Reversible heat pump, total heat recovery, geothermal source 4,5 ÷ 29,7 kW Unit description PRANA DHW is the heat pump new generation able to operate throughout the year in any operating mode: either a single cycle (air conditioning, heating, hot water) and combined cycle (hot water along with air conditioning or heating). Energy efficiency is highest during the summer cycle, when, thanks to the full recovery of the heat, the production of hot water is free. During the combined use, the DHW exchanger uses the temperature of the hot exhaust gases to gets inside the accumulation sanitary water as high as 65° C. The advanced CLIMAVENETA fully patented electronic ensures the highest flexibility of operation, a rapid speed and a significant increase in the overall COP, which go hand in hand with electricity and space reduction. Advantages, combined with the possibility of completely eliminating the traditional boiler, making heat pumps PRANA DHW the ideal solution for energy saving applications in residential, hotel and small sector. Commands User interface unit on board, accessible from the outside with a not touch system BWR-DHW heats water stored in the tank as energy storage. It also comes with a state-of-the-art electronic unit, which independently controls the modes of operation. The appliance can operate throughout the year in any mode, both with single cycle (cooling, heating, hot water) and with combined cycle (hot water together with cooling or hot water together heating).During the summer cycle there is maximum energy saving through total heat recovery. This energy is completely free of charge with regard to the production of hot water. 72 Structure and base in hot galvanised epoxy powder coated steel. Case panels are insulated within low noise material for further improvement of silence Rubber vibration damper. Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection Stainless steel (AISI 316) with high efficiency and low pressure drop plate to plate exchanger (at the domestic hot water side). It is positioned next after the compressor, it ensures the domestic hot water production. That can work either in full recovery or in part, with the constant optimization of efficiency through logic advanced adjusting controller Exchangers plant side plate of stainless steel AISI 316 with high efficiency and low pressure drop meets the supply of both hot or cold water for the facility, regardless of the domestic hot water High efficiency and low pressure drop stainless steel (AISI 316) source side plate exchanger Soft starter for 230V/1/50Hz units /ms The water circuit comes complete with: • Variable flow circulator for 0011÷0031 models and multistage centrifugal variable flow pump for models 0071÷0121, plant side • Domestic hot water, water side, variable flow pump • Variable flow circulator for 0011÷0031 models, multistage centrifugal variable flow pump for models 0071-0121 on source side (for geothermal systems, closed vertical or horizontal loops) • Safety valve • Expansion tank • Drain valve on both plant and source circuits Main accessories • Buffer tank 35,100,200 liters • Hot water cylinder 300,500 liters • 300 litres thermal store for domestic hot water, for kit DOMH2O • 300,500,1000 litres thermal store for domestic hot water with solar heat exchanger, for kit DOMH2O • DOMH2O15 e DOMH2O24 kit for domestic hot water with external heat exchanger plate-to-plate and pump • Remote keyboard • Removable metal mesh water filter kit BWR DHW Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Total absorbed power Total absorbed power Recovery heating capacity Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER Compressor type N. Compressors Refrigerant Plant side pump type Recovery side pump type Source side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight Models Nominal heating power Total absorbed power COP Cooling capacity Total absorbed power EER Total absorbed power Total absorbed power Recovery heating capacity Heating capacity Total absorbed power COP Cooling capacity Total absorbed power EER Compressor type N. Compressors Refrigerant Plant side pump type Recovery side pump type Source side pump type Electrical power supply Start-up current Sound power Sound pressure DIMENSION L H P Operational weight (1) (2) kW kW (3) (2) kW kW (4) (4) (5) (2) kW kW kW kW kW (6) (2) kW kW 0011m 4,50 1,30 3,44 7,30 1,30 5,62 6 1,90 7,90 4,30 1,70 2,60 5,10 1,30 3,92 0021m 5,70 1,60 3,45 9,20 1,70 5,41 7,80 2,40 10 5,50 2,10 2,63 6,50 1,70 3,82 Ci Ci Ci 230-1~50 47 52 38 Ci Ci Ci 230-1~50 61 52 38 0025m 6,70 1,90 3,48 11 2 5,50 9,20 2,90 11,9 6,60 2,50 2,64 7,70 2 3,85 0031m 7,80 2,30 3,39 12,5 2,40 5,21 10,3 3,40 13,5 7,70 3 2,59 8,90 2,40 3,71 N. (7) (7) (7) (8) (9) V-Ph~Hz A dB(A) dB(A) mm mm mm kg (1) (2) (3) (2) (4) (4) (5) (2) (6) (2) N. (7) (7) (7) (8) (9) Ci Ci Ci Ci Ci Ci 230-1~50 230-1~50 76 100 53 53 39 39 0041m 0011ms 9,70 4,50 2,80 1,30 3,51 3,44 15,3 7,30 2,90 1,30 5,28 5,62 12,9 6 4,20 1,90 16,8 7,90 9,40 4,30 3,50 1,70 2,69 2,60 11 5,10 2,90 1,30 3,79 3,92 SCROLL 1 R407C Ci Ci Ci Ci Ce Ci 230-1~50 230-1~50 114 21 58 52 44 38 0021ms 5,70 1,60 3,45 9,20 1,70 5,41 7,80 2,40 10 5,50 2,10 2,63 6,50 1,70 3,82 0025ms 6,70 1,90 3,48 11 2 5,50 9,20 2,90 11,9 6,60 2,50 2,64 7,70 2 3,85 0031ms 7,80 2,30 3,39 12,5 2,40 5,21 10,3 3,40 13,5 7,70 3 2,59 8,90 2,40 3,71 0041ms 9,70 2,80 3,51 15,3 2,90 5,28 12,9 4,20 16,8 9,40 3,50 2,69 11 2,90 3,79 Ci Ci Ci 230-1~50 27 52 38 Ci Ci Ci 230-1~50 34 53 39 Ci Ci Ci 230-1~50 45 53 39 Ci Ci Ce 230-1~50 51 58 44 188 190 195 215 560 980 575 188 188 190 195 0021t 5,60 1,60 3,50 9,20 1,60 5,75 7,70 2,30 9,90 5,40 2 2,67 6,50 1,70 3,82 0025t 6,60 1,90 3,51 10,9 1,90 5,74 9,10 2,80 11,7 6,50 2,40 2,67 7,70 2 3,85 0031t 7,70 2,20 3,44 12,4 2,30 5,39 10,3 3,30 13,4 7,50 2,90 2,63 8,80 2,30 3,83 0041t 9,50 2,70 3,56 15,4 2,80 5,50 13,1 4 16,9 9,30 3,40 2,75 10,9 2,80 3,89 560 980 575 188 560 980 575 190 560 980 575 195 560 980 575 215 215 188 0051t 0061t 0071t 0091t 0101t 0121t 11,4 13,9 18,8 21,2 24,4 29,7 3,20 3,70 5,10 5,60 6,60 8,30 3,57 3,72 3,70 3,81 3,72 3,57 kW 19,1 22,5 30,2 34,4 38,9 49,7 kW 3,60 4,10 5,50 6,10 7,30 9,30 5,31 5,49 5,49 5,64 5,33 5,34 kW 16 18,9 25,5 29 32,7 41,1 kW 4,90 5,70 7,70 8,40 10,2 12,8 kW 20,6 24,2 32,7 36,9 42,4 53,1 kW 11,1 13,3 17,9 20,5 23,5 28,4 kW 4 4,70 6,50 7 8,30 10,5 2,78 2,86 2,77 2,95 2,84 2,69 kW 13,4 16,1 21,7 24,6 28 34,8 kW 3,40 4 5,40 5,90 7 8,90 3,94 4,03 4,02 4,17 4,00 3,91 SCROLL 1 R407C Ci Ci Ci Ci Ci Ci Ce Ce Ce Ce Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ce Ce Ce Ce Ce Ce Ce V-Ph~Hz 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 A 32 40 46 50 66 74 95 111 118 140 dB(A) 52 52 52 58 58 59 66 66 70 70 dB(A) 38 38 38 44 44 45 51 51 55 55 kW kW mm mm mm kg 560 980 575 228 NOTE (1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side) (2) According to Eurovent (3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side) (4) Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side) (5) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side) (6) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side) (7) Ci=Circolatore; Ce=Centrifuga (8) Sound power level according to ISO 9614 and Eurovent 8/1 (9) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit. 73 560 980 575 233 680 1150 780 260 680 1150 780 270 680 1150 780 280 680 1150 780 305 L P H DRONIC R 74 hydronic chiller CHILLER hydronic - chiller 75 Hydronic - chiller NECS 0152÷1204 Versions B HL HT LN SL base version low noise, high efficiency, high outdoor temperature version high efficiency, high outdoor temperature version low noise version super-low noise version Configurations D R base function partial condensing heat recovery function total condensing heat recovery function Features Chiller, air source for outdoor installation 33,8 - 341 kW Unit Description Outdoor unit for the production of chilled water with hermetic rotary Scroll compressors dedicated for the use of R410A, axial-flow fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in Peraluman and structure in aluminium sections. The range includes the single-circuit two-compressor versions and the dual circuit fourcompressor versions. REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY Climaveneta is the only company to offer units with Scroll compressors in 5 versions and 3 different configurations designed to satisfy all service system and application requirements STANDARD SUPPLY WITH WATER FILTER ALREADY INSTALLED The water filter is already installed as standard supply on all units, including those without hydronic kit. This simplifies installation procedures, while ensuring maximum working reliability INTEGRATED HYDRONIC MODULE The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank Main accessories Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. 76 UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊElectronic expansion valve UÊRubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only) PLATES r HFC R-410A SCROLL AXIAL COOLING NECS / B Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552 38,1 14,4 2,65 4,05 45,1 15,6 2,89 4,29 50,5 19,1 2,64 4,22 57 21,5 2,65 4,15 76 27,8 2,73 4,15 86,8 31,9 2,72 4,27 96,9 36,3 2,67 4,17 112 39,6 2,83 4,30 127 43,8 2,90 4,25 145 50,5 2,87 4,40 39,5 12,9 11,9 46,8 14,1 13 52,4 17,4 16,1 59,2 19,8 18,3 78,9 25,4 23,5 90,1 29,3 27,1 101 33,6 31,1 117 36,4 33,6 131 39,8 36,8 150 46 42,6 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 84 52 84 52 84 52 84 52 85 53 86 54 86 54 86 54 87 55 87 55 1695 1120 1420 380 1695 1120 1420 410 1695 1120 1420 420 1695 1120 1420 430 2195 1120 1420 630 2195 1120 1420 660 2745 1120 1420 740 2745 1120 1420 800 3245 1120 1620 950 3245 1120 1620 970 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204 159 58,7 2,71 4,20 113 45,6 2,48 4,10 136 53,8 2,53 3,60 154 59,7 2,58 3,79 177 67,8 2,61 3,91 200 74,9 2,67 4,08 223 84,2 2,65 4,15 255 94,1 2,71 3,96 293 106 2,76 4,10 325 121 2,68 4,16 165 54,2 50,1 118 40 37 141 43,8 40,5 160 49,6 45,9 183 57,2 53 207 64,2 59,4 232 73,3 67,8 265 78,7 72,8 304 90,4 83,6 337 105 97 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 87 55 91 59 92 60 92 60 92 60 92 60 93 61 94 62 95 63 95 63 3245 1120 1620 980 3110 2220 1700 1230 3110 2220 1700 1450 3110 2220 1700 1620 3110 2220 2150 1780 3110 2220 2150 1890 4110 2220 2150 2070 4110 2220 2150 2220 4110 2220 2150 2380 4110 2220 2150 2530 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 77 NECS / HL Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 118 43,7 2,70 3,93 136 49,8 2,73 4,04 151 58,1 2,60 4,02 172 66,7 2,58 4,15 201 72,8 2,76 4,02 222 83,8 2,65 4,04 249 91,9 2,71 4,14 290 102 2,83 4,37 326 117 2,77 4,16 123 42,4 34,8 141 48,4 40,4 157 56,2 47,5 178 64,4 55,1 209 70,7 58,7 231 81,1 68,3 258 88,8 75,5 301 99,1 85,1 338 104 96,5 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 86 54 86 54 86 54 86 54 88 56 88 56 88 56 90 58 91 59 3110 2220 1700 1360 3110 2220 2150 1570 3110 2220 2150 1710 3110 2220 2150 1860 4110 2220 2150 2120 4110 2220 2150 2180 4110 2220 2150 2320 5110 2220 2150 2630 5110 2220 2150 2770 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 78 NECS / HT Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0152 0182 0202 0252 0302 0352 0412 0452 0512 39,7 13,5 2,94 4,28 46,7 15,2 3,07 4,18 55 17,3 3,18 4,41 61,6 20,3 3,03 4,09 80,6 25,9 3,11 4,27 91,4 30,5 3 4,18 104 33,7 3,09 4,28 116 38,7 3 4,31 130 42,2 3,08 4,39 41,2 12,1 11,2 48,5 13,3 12,3 57 15,3 14,1 63,9 17,7 16,3 83,6 23,1 21,3 94,9 27,1 25 108 30,1 27,8 120 34,8 32,2 135 38,3 35,5 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 84 52 85 53 85 53 86 54 86 54 87 55 87 55 87 55 87 55 1695 1120 1420 400 2195 1120 1420 460 2195 1120 1420 490 2745 1120 1420 550 2745 1120 1420 710 3245 1120 1620 800 3245 1120 1620 880 3245 1120 1620 930 3245 1120 1620 960 0504 0524 0604 0704 0804 0904 1004 1104 1204 123 45,4 2,71 3,63 142 50,5 2,81 3,76 159 57,8 2,75 3,90 182 65 2,80 4,02 210 74,5 2,82 3,82 233 84,1 2,77 3,86 262 90,7 2,89 4,08 303 101 2,99 4,25 341 117 2,91 4,08 127 44 32,9 147 49,2 37,7 165 55,9 43,9 189 63 50,5 218 72,2 55,1 242 81,5 63,8 272 88,1 69,8 315 98,4 85,8 354 114 97,1 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 92 60 92 60 92 60 92 60 94 62 94 62 94 62 96 64 97 65 3110 2220 1700 1360 3110 2220 2150 1570 3110 2220 2150 1710 3110 2220 2150 1860 4110 2220 2150 2120 4110 2220 2150 2180 4110 2220 2150 2320 5110 2220 2150 2630 5110 2220 2150 2770 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 79 NECS / LN Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552 36,1 15 2,41 4,03 42,8 16,4 2,61 4,20 50,7 19 2,67 4,25 57,6 21,3 2,70 4,22 74,2 28,7 2,59 4,11 84,4 33,8 2,50 3,99 96,4 37,1 2,60 4,02 109 41,4 2,63 4,15 122 45,9 2,66 4,06 139 53,3 2,61 4,19 37,5 13,9 12,9 44,4 15,3 14,1 52,6 17,3 16 59,8 19,6 18,1 77 26,4 24,4 87,6 30,5 28,3 100 33,8 31,3 113 38 35,2 127 41,9 38,7 144 48,8 45,2 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 79 47 79 47 80 48 80 48 81 49 83 51 83 51 83 51 84 52 84 52 1695 1120 1420 380 1695 1120 1420 410 2195 1120 1420 470 2195 1120 1420 510 2745 1120 1420 680 2745 1120 1620 730 2745 1120 1620 800 2745 1120 1620 840 3245 1120 1620 950 3245 1120 1620 970 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204 151 62,4 2,42 3,96 104 47,9 2,17 3,93 129 53,5 2,41 3,84 147 60 2,45 3,91 167 69,6 2,40 4,01 187 77,6 2,41 3,99 208 87,8 2,37 4,07 242 95,3 2,54 4,01 275 109 2,52 4,15 306 125 2,44 4,06 157 57,8 53,5 108 46,6 40,9 134 51,8 43,5 153 58,2 49,3 173 67,1 57,6 194 75,3 65,2 216 85,2 74,4 251 92 78,4 286 106 91,3 317 121 105 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 84 52 85 53 86 54 86 54 86 54 86 54 87 55 88 56 89 57 89 57 3245 1120 1620 980 3110 2220 1700 1230 3110 2220 1700 1450 3110 2220 1700 1620 3110 2220 2150 1780 3110 2220 2150 1890 4110 2220 2150 2070 4110 2220 2150 2220 4110 2220 2150 2380 4110 2220 2150 2530 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 80 NECS / SL Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0152 0182 0202 0252 0302 0352 0412 0452 0512 33,8 16,3 2,07 3,77 42,3 17,1 2,47 3,93 47,8 20,4 2,34 4,01 55,5 22,6 2,46 3,89 69,9 30,9 2,26 3,86 85,4 33,6 2,54 3,87 96,8 37,2 2,60 3,91 106 43,1 2,46 3,91 118 48,4 2,44 3,90 35 15,1 14 43,9 15,5 14,3 49,6 18,7 17,3 57,5 20,6 19 72,6 28,6 26,4 88,6 30 27,8 101 33,6 31,1 110 39,3 36,3 122 44 40,7 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 76 44 77 45 77 45 78 46 78 46 81 49 81 49 81 49 82 50 1695 1120 1420 400 2195 1120 1420 460 2195 1120 1420 490 2745 1120 1420 550 2745 1120 1420 710 3245 1120 1620 800 3245 1120 1620 880 3245 1120 1620 930 3245 1120 1620 960 0504 0524 0604 0704 0804 0904 1004 1104 1204 113 45,2 2,50 4,02 130 51,8 2,51 4,14 147 58,8 2,50 4,14 161 70,6 2,28 4,13 193 75,4 2,56 4,08 211 87,2 2,42 4,08 235 96,7 2,43 4,10 278 106 2,61 4,39 313 121 2,58 4,19 117 43,7 37,2 135 50,2 43,2 152 56,9 49,5 167 68,4 60,1 200 72,8 62,6 219 84,3 73,2 243 93,2 81,5 288 103 90,2 325 117 102 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 298 258 79,8 333 295 92,8 382 325 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 82 50 82 50 82 50 82 50 83 51 83 51 83 51 85 53 86 54 3110 2220 1700 1360 3110 2220 2150 1570 3110 2220 2150 1770 3110 2220 2150 1860 4110 2220 2150 2120 4110 2220 2150 2180 4110 2220 2150 2320 5110 2220 2150 2630 5110 2220 2150 2770 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-0512 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 0504-1204 600 600 1000 H 1100 1100 2000 H A B A B 81 Hydronic - chiller NECS 0202T÷0612T Versions B HT LN SL base version high efficiency, high outdoor temperature version low noise version super-low noise version Features Chiller, air source for outdoor installation 53,0 - 159 kW REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) SHELL AND TUBES EXCHANGER The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets. INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head. MAXIMUM RELIABILITY Unit with dual-circuit refrigerant section designed to ensure maximum efficiency at full load, ensuring continuity without interruption of operation in the event of temporary stop of one of the 2 circuits. Main accessories Unit Description Outdoor unit for the production of chilled water with hermetic rotary Scroll compressors, axialflow fans, shell and tubes exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with two compressors on two independent refrigerant circuits. Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 82 UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊLCD display keyboard type W3000Compact with multilanguage user interface (refers to the shown picture) UÊSoft starters UÊRubber anti-vibration mounting kit SHELL & TUBES SCROLL AXIAL COOLING NECS / B Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T kW kW 53 18,3 2,90 3,72 58,1 21,5 2,70 3,47 76,0 27,8 2,73 3,52 86,8 31,9 2,72 3,49 96,9 36,3 2,67 3,41 112 39,7 2,67 3,59 127 43,7 2,90 3,65 145 50,2 2,89 3,66 159 58,6 2,71 3,44 N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 85 53 85 53 85 53 86 54 86 54 86 54 87 55 87 55 87 55 1695 1120 1420 625 1695 1120 1420 625 2195 1120 1420 665 2195 1120 1420 765 2745 1120 1420 920 2745 1120 1420 990 3245 1120 1620 1135 3245 1120 1620 1180 3245 1120 1620 1155 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories NECS / HT Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0202T 0252T 0302T 0352T 0412T 0452T 0512T kW kW 55 17,3 3,18 4,07 61,6 20,3 3,03 3,91 80,6 25,9 3,11 3,93 91,4 30,5 3 3,76 104 33,7 3,09 3,87 116 38,6 3 3,76 130 42,2 3,08 3,86 N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 85 53 86 54 86 54 87 55 87 55 87 55 87 55 2195 1120 1420 650 2745 1120 1420 700 2745 1120 1420 750 3245 1120 1620 915 3245 1120 1620 1050 3245 1120 1620 1075 3245 1120 1620 1115 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories NECS / LN Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T kW kW 50,7 18,9 2,68 3,50 57,6 21,2 2,72 3,51 74,2 28,6 2,59 3,37 84,4 33,7 2,50 3,22 96,4 37,1 2,60 3,33 109 41,4 2,63 3,36 122 45,9 2,66 3,38 0 53,1 0 3,34 0 62,4 0 3,11 N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 80 48 80 48 81 49 83 51 83 51 83 51 84 52 84 52 84 52 2195 1120 1420 625 2195 1120 1420 650 2745 1120 1420 715 2745 1120 1620 840 2745 1120 1620 965 2745 1120 1620 1025 3245 1120 1620 1135 3245 1120 1620 1180 3245 1120 1620 1155 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories 83 NECS / SL Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0202T 0252T 0302T 0352T 0412T 0452T 0512T kW kW 47,8 20,3 2,35 55,5 22,6 2,46 69,9 30,9 2,26 85,4 33,6 2,54 96,8 37,3 2,60 106 43,2 2,46 118 48,1 2,44 N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 77 45 78 46 78 46 81 49 81 49 81 49 82 50 2195 1120 1420 650 2745 1120 1420 700 2745 1120 1420 750 3245 1120 1620 915 3245 1120 1620 1050 3245 1120 1620 1075 3245 1120 1620 1115 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0202T-0512T Switchboard side Switchboard opposite side Condensation coil side mm mm mm 600 600 1000 H A B 84 85 Hydronic - chiller NECS 1314÷3218 Versions B SL CA SL-CA base version super-low noise version Class A of efficiency Super Low noise version, Class A of efficiency Configurazioni D R funzione base partial condensing heat recovery function total condensing heat recovery function Features Chiller, air source for outdoor installation 354 - 885 kW Unit Description Outdoor unit for the production of chilled water with hermetic rotary Scroll compressors, ozone-friendly refrigerant R410A, axial-flow fans, shell and tubes exchanger and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration. Commands W3000SE Compact The W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) ALUMINIUM MICRO-CHANNEL HEAT EXCHANGERS The new NECS uses aluminium micro-channel condensers that ensure a premium level of efficiency. This solution also allows to reduce the refrigerant charge with respect to traditional copper/aluminium coils as well as improving the resistance against corrosion in saline or corrosive atmospheres. SHELL AND TUBES EXCHANGER The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets. ELECTRONIC EXPANSION VALVE SUPPLIED STANDARD The use of the electronic expansion valve generates considerable benefits, especially in cases of variable demand and different external conditions. It was introduced into these units as a result of accurate design choices concerning the cooling circuit and the optimisation of operation in various different working conditions CLASS A EFFICIENCY The full range is also available with the Class A efficiency rating. NECS/CA guaranties premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans. INTEGRATED HYDRONIC MODULE The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank Main accessories UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters 86 ENERGY CLASS SHELL & TUBES AXIAL SCROLL COOLING NECS / B Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1314 1414 1614 1715 2015 1816 2116 kW kW 354 124 2,85 * 379 130 2,91 * 413 148 2,80 * 458 160 2,86 * 526 184 2,86 * 501 172 2,92 * 569 195 2,91 * N. 4/2 4/2 4/2 5/2 5/2 6/2 6/2 96 64 96 64 96 64 96 64 97 65 97 65 97 65 3905 2260 2450 * 3905 2260 2450 * 3905 2260 2450 * 5080 2260 2450 * 5080 2260 2450 * 5080 2260 2450 * 6255 2260 2450 * 2316 2416 2418 2618 2818 3018 3218 kW kW 604 214 2,82 * 635 219 2,90 * 665 234 2,85 * 708 249 2,85 * 759 261 2,92 * 794 279 2,84 * 827 296 2,80 * N. 6/3 6/2 8/4 8/4 8/4 8/4 8/4 97 65 98 66 98 65 98 65 99 66 99 66 99 66 6255 2260 2450 * 6255 2260 2450 * 7430 2260 2450 * 7430 2260 2450 * 7430 2260 2450 * 7430 2260 2450 * 7430 2260 2450 * dB(A) dB(A) mm mm mm kg Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories NECS / SL Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1314 1414 1614 1715 2015 1816 2116 kW kW 334 129 2,58 * 358 137 2,61 * 397 153 2,60 * 432 168 2,57 * 498 192 2,60 * 465 183 2,55 * 532 206 2,58 * N. 4/2 4/2 4/2 5/2 5/2 6/2 6/2 88 56 88 56 88 56 88 56 90 58 89 57 90 57 5080 2260 2450 * 5080 2260 2450 * 5080 2260 2450 * 6255 2260 2450 * 6255 2260 2450 * 6255 2260 2450 * 7430 2260 2450 * 2316 2416 2418 2618 2818 3018 3218 kW kW 579 220 2,63 * 596 230 2,59 * 616 245 2,52 * 666 258 2,58 * 718 275 2,61 * 758 288 2,63 * 795 306 2,60 * N. 6/3 6/2 8/4 8/4 8/4 8/4 8/4 91 58 91 58 91 58 91 58 92 59 92 59 92 59 7430 2260 2450 * 7430 2260 2450 * 7430 2260 2450 * 8605 2260 2450 * 9780 2260 2450 * 9780 2260 2450 * 9780 2260 2450 * dB(A) dB(A) mm mm mm kg Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories 87 NECS / CA Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1314 1414 1614 1715 2015 1816 2116 kW kW 370 120 3,10 * 391 125 3,13 * 438 142 3,10 * 481 154 3,12 * 549 177 3,10 * 518 166 3,11 * 591 189 3,12 * N. 4/2 4/2 4/2 5/2 5/2 6/2 6/2 97 65 97 65 97 65 97 65 98 66 98 66 98 65 5080 2260 2450 * 5080 2260 2450 * 5080 2260 2450 * 6255 2260 2450 * 6255 2260 2450 * 6255 2260 2450 * 7430 2260 2450 * 2316 2416 2418 2618 2818 3018 3218 kW kW 633 204 3,10 * 657 212 3,10 * 702 225 3,11 * 740 239 3,10 * 785 250 3,13 * 831 267 3,12 * 885 283 3,13 * N. 6/3 6/2 8/4 8/4 8/4 8/4 8/4 99 66 99 66 99 66 99 66 100 67 100 67 100 67 7430 2260 2450 * 7430 2260 2450 * 9780 2260 2450 * 9780 2260 2450 * 9780 2260 2450 * 9780 2260 2450 * 9780 2260 2450 * dB(A) dB(A) mm mm mm kg Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1314-3218 Switchboard side Switchboard opposite side Plant exchagers opposite side Plant exchagers side mm mm mm mm 1500 1500 1500 2000 88 NECS / SL-CA Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1314 1414 1614 1715 2015 1816 2116 2316 2416 2418 kW kW 371 119 3,11 4,57 394 126 3,12 4,56 440 142 3,11 4,44 481 154 3,12 4,54 550 177 3,11 4,52 522 167 3,12 4,58 592 189 3,13 4,60 638 204 3,12 4,59 663 213 3,11 4,53 695 223 3,12 4,58 N. 4/2 4/2 4/2 5/2 5/2 6/2 6/2 6/3 6/2 8/4 86 53 86 53 86 53 87 54 87 54 87 54 87 54 88 55 88 55 88 55 6255 2260 2450 3490 6255 2260 2450 3700 6255 2260 2450 3730 7430 2260 2450 4400 7430 2260 2450 4510 7430 2260 2450 4650 8605 2260 2450 4990 8605 2260 2450 5360 8605 2260 2450 5360 9780 2260 2450 6100 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1314-2418 Switchboard side Switchboard opposite side Plant exchagers opposite side Plant exchagers side mm mm mm mm 1500 1500 1500 2000 H B 89 A Hydronic - chiller NECS-ST 0504÷1204 Versions B HL HT LN SL base version low noise, high efficiency, high outdoor temperature version high efficiency, high outdoor temperature version low noise version super-low noise version Configurations D R base function partial condensing heat recovery function total condensing heat recovery function Features Chiller, air source for outdoor installation 104 - 341 kW Unit Description Outdoor unit for the production of chilled water with hermetic rotary Scroll compressors, axialflow fans, shell and tubes exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with four compressors on two independent refrigerant circuits. REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY Climaveneta is the only company to offer units with Scroll compressors in 5 versions and 3 different configurations designed to satisfy all service system and application requirements SHELL AND TUBES EXCHANGER The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets. INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head. Commands Main accessories W3000SE Compact UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊElectronic expansion valve UÊRubber anti-vibration mounting kit. Spring anti-vibration mounting kit The W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). All /R units adopt the W3000 SE Large controller. 90 SHELL & TUBES r HFC R-410A SCROLL AXIAL COOLING NECS-ST / B Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 113 45,6 2,48 4,10 136 53,8 2,53 3,60 154 59,7 2,58 3,79 177 67,8 2,61 3,91 200 74,9 2,67 4,08 223 84,2 2,65 4,15 255 94,1 2,71 3,96 293 106 2,76 4,10 325 121 2,68 4,16 118 40 37 141 43,8 40,5 160 49,6 45,9 183 57,2 53 207 64,2 59,4 232 73,3 67,8 265 78,7 72,8 304 90,4 83,6 337 105 97 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 91 59 92 60 92 60 92 60 92 60 93 61 94 62 95 63 95 63 3110 2220 1700 1230 3110 2220 1700 1450 3110 2220 1700 1620 3110 2220 2150 1780 3110 2220 2150 1890 4110 2220 2150 2070 4110 2220 2150 2220 4110 2220 2150 2380 4110 2220 2150 2530 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories NECS-ST / HL Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 118 43,7 2,70 3,93 136 49,8 2,73 4,04 151 58,1 2,60 4,02 172 66,7 2,58 4,15 201 72,8 2,76 4,02 222 83,8 2,65 4,04 249 91,9 2,71 4,14 290 102 2,83 4,37 326 117 2,77 4,16 123 42,4 34,8 141 48,4 40,4 157 56,2 47,5 178 64,4 55,1 209 70,7 58,7 231 81,1 68,3 258 88,8 75,5 301 99,1 85,1 338 104 96,5 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 86 54 86 54 86 54 86 54 88 56 88 56 88 56 90 58 91 59 3110 2220 1700 1360 3110 2220 2150 1570 3110 2220 2150 1710 3110 2220 2150 1860 4110 2220 2150 2120 4110 2220 2150 2180 4110 2220 2150 2320 5110 2220 2150 2630 5110 2220 2150 2770 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 91 NECS-ST / HT Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 123 45,4 2,71 3,63 142 50,5 2,81 3,76 159 57,8 2,75 3,90 182 65 2,80 4,02 210 74,5 2,82 3,82 233 84,1 2,77 3,86 262 90,7 2,89 4,08 303 101 2,99 4,25 341 117 2,91 4,08 127 44 32,9 147 49,2 37,7 165 55,9 43,9 189 63 50,5 218 72,2 55,1 242 81,5 63,8 272 88,1 69,8 315 98,4 85,8 354 114 97,1 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 92 60 92 60 92 60 92 60 94 62 94 62 94 62 96 64 97 65 3110 2220 1700 1360 3110 2220 2150 1570 3110 2220 2150 1710 3110 2220 2150 1860 4110 2220 2150 2120 4110 2220 2150 2180 4110 2220 2150 2320 5110 2220 2150 2630 5110 2220 2150 2770 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories NECS-ST / LN Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 104 47,9 2,17 3,93 129 53,5 2,41 3,84 147 60 2,45 3,91 167 69,6 2,40 4,01 187 77,6 2,41 3,99 208 87,8 2,37 4,07 242 95,3 2,54 4,01 275 109 2,52 4,15 306 125 2,44 4,06 108 46,6 40,9 134 51,8 43,5 153 58,2 49,3 173 67,1 57,6 194 75,3 65,2 216 85,2 74,4 251 92 78,4 286 106 91,3 317 121 105 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 299 258 79,8 333 295 92,8 382 333 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 85 53 86 54 86 54 86 54 86 54 87 55 88 56 89 57 89 57 3110 2220 1700 1230 3110 2220 1700 1450 3110 2220 1700 1620 3110 2220 2150 1780 3110 2220 2150 1890 4110 2220 2150 2070 4110 2220 2150 2220 4110 2220 2150 2380 4110 2220 2150 2530 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 92 NECS-ST / SL Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 113 45,2 2,50 4,02 130 51,8 2,51 4,14 147 58,8 2,50 4,14 161 70,6 2,28 4,13 193 75,4 2,56 4,08 211 87,2 2,42 4,08 235 96,7 2,43 4,10 278 106 2,61 4,39 313 121 2,58 4,19 117 43,7 37,2 135 50,2 43,2 152 56,9 49,5 167 68,4 60,1 200 72,8 62,6 219 84,3 73,2 243 93,2 81,5 288 103 90,2 325 117 102 118 38,7 155 138 44,1 179 158 49,4 204 181 56,9 234 204 64,5 264 231 72,1 298 258 79,8 333 295 92,8 382 325 105 431 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 82 50 82 50 82 50 82 50 83 51 83 51 83 51 85 53 86 54 3110 2220 1700 1360 3110 2220 2150 1570 3110 2220 2150 1770 3110 2220 2150 1860 4110 2220 2150 2120 4110 2220 2150 2180 4110 2220 2150 2320 5110 2220 2150 2630 5110 2220 2150 2770 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0504-1204 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 H B A 93 Hydronic - chiller FOCS 0751÷2632 Versions B LN SL base version low noise version super-low noise version Configurations D R base function partial condensing heat recovery function total condensing heat recovery function Features Chiller, air source for outdoor installation FLEXIBILITY Flexibility in applications thanks to the many available functions and versions ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic EXTENSIVE RANGE OF OPERATION Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C. INTEGRATED HYDRONIC MODULE Optional pump unit also with storage tank, consisting of 1 or 2 pumps, 2 or 4-pole motor, with three head options to satisfy different industrial applications and demands for comfort 145 - 516 kW Unit Description Main accessories Outdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, plate evaporator and thermostatic expansion valve. Frame with base in polyester-painted thick hot-galvanised sheet steel and external panels in peraluman. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. UÊSoft start UÊCompressor power factor device UÊElectronic expansion valve UÊVariable speed condensation control (standard on /LN, /SL) UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊHydronic group with possible storage tank Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. 94 PLATES r HFC R-134a SCREW AXIAL COOLING FOCS / B Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0751 0851 0951 0961 1021 1301 1532 1732 1932 1952 2432 2632 145 51,6 2,81 3,50 163 61,1 2,67 3,42 182 68,4 2,66 3,52 201 75 2,68 3,63 234 85,1 2,75 3,49 266 93,3 2,85 3,54 277 103 2,67 3,64 329 121 2,71 3,57 366 138 2,64 3,56 398 154 2,58 3,58 466 178 2,61 3,61 516 193 2,67 3,49 150 49,9 40,8 169 59 49,2 189 66,5 56,2 209 72,7 61,8 243 82,7 68,4 276 90,5 75,7 148 43,8 190 171 51 220 190 59,3 246 211 61,6 269 241 70,1 307 275 80,4 351 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 94 62 94 62 94 62 94 62 96 64 96 64 97 65 97 65 97 65 97 65 99 67 99 67 3110 2220 2150 1680 3110 2220 2150 1710 3110 2220 2150 1780 3110 2220 2150 1860 4610 2220 2150 2590 4610 2220 2150 2720 4610 2220 2150 2970 4610 2220 2420 3160 4610 2220 2420 3300 4610 2220 2420 3320 5610 2220 2430 4400 5610 2220 2430 4620 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories FOCS / LN Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0751 0851 0951 0961 1021 1301 1532 1732 1932 1952 2432 2632 141 51,3 2,75 3,69 157 61,1 2,57 3,51 175 70 2,50 3,57 195 77,4 2,52 3,69 229 86,7 2,64 3,65 256 94,8 2,70 3,59 266 105 2,51 3,68 310 124 2,50 3,58 345 143 2,40 3,61 376 164 2,29 3,61 440 185 2,37 3,62 483 201 2,40 3,48 146 49,3 42,5 162 59 51,4 181 67,6 59,4 202 74,8 66,1 237 83,7 72,7 265 91,4 79,9 139 51,5 45,1 157 60,6 53,5 172 71 63,2 205 73,7 64,3 231 87,3 76,9 247 98 86,9 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 88 56 88 56 88 56 88 56 90 58 90 58 91 59 91 59 91 59 91 59 93 61 93 61 3110 2220 2150 1680 3110 2220 2150 1710 3110 2220 2150 1780 3110 2220 2150 1860 4610 2220 2150 2590 4610 2220 2150 2720 4610 2220 2150 2970 4610 2220 2420 3160 4610 2220 2420 3300 4610 2220 2420 3320 5610 2220 2430 4400 5610 2220 2430 4620 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 95 FOCS / SL Models COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0751 0851 0951 0961 1021 1301 1532 1732 1932 1952 2432 2632 134 53,2 2,52 3,54 151 62,7 2,41 3,41 166 73,8 2,25 3,40 197 76,1 2,59 3,69 223 90,3 2,47 3,58 238 101 2,35 3,32 252 111 2,26 3,50 296 128 2,31 3,47 334 149 2,24 3,46 377 164 2,29 3,62 443 183 2,41 3,69 484 199 2,43 3,52 148 43,8 190 172 51 220 190 59,3 246 211 61,6 269 241 70,1 307 275 80,4 351 148 43,8 190 172 51 220 190 59,3 246 211 61,6 269 241 70,1 307 275 80,4 351 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 84 52 84 52 84 52 84 52 86 54 86 54 86 54 87 55 87 55 87 55 89 56 89 56 3110 2220 2150 1680 3110 2220 2150 1770 3110 2220 2150 1840 4110 2220 2150 1980 4610 2220 2150 2670 4610 2220 2150 2720 4610 2220 2150 3060 4610 2220 2420 3270 5610 2220 2430 3460 5610 2220 2430 3640 6610 2220 2430 4990 6610 2220 2430 5250 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0751-1952 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1500 1500 2000 2432-2632 2000 1800 3000 96 97 Hydronic - chiller FOCS 1542÷2642 Versions B LN SL base version low noise version super-low noise version Configurations D R base function partial condensing heat recovery function total condensing heat recovery function Features FLEXIBILITY Flexibility in applications thanks to the many available functions and versions ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic EXTENSIVE RANGE OF OPERATION Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C. Chiller, air source for outdoor installation Main accessories 277 - 516 kW Unit Description Outdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Frame with base in polyester-painted thick hot-galvanised sheet steel and external panels in peraluman. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. 98 UÊSoft start UÊCompressor power factor device UÊElectronic expansion valve UÊVariable speed condensation control (standard on /LN, /SL) UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board SHELL & TUBES r HFC R-134a SCREW AXIAL COOLING FOCS / B Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1542 1742 1942 1962 2442 2642 kW kW 277 103 2,67 3,64 329 121 2,71 3,57 366 138 2,64 3,56 398 154 2,58 3,58 466 178 2,61 3,61 516 193 2,67 3,49 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 97 65 97 65 97 65 97 65 99 67 99 67 4610 2220 2150 3490 4610 2220 2150 3680 4610 2220 2150 3810 4610 2220 2150 4100 4610 2220 2150 5140 4610 2220 2150 5340 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories FOCS / LN Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1542 1742 1942 1962 2442 2642 kW kW 266 105 2,51 3,68 310 124 2,50 3,58 345 143 2,40 3,61 376 164 2,29 3,61 440 185 2,37 3,62 483 201 2,40 3,48 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 91 59 91 59 91 59 91 59 93 61 93 61 4610 2220 2150 3490 4610 2220 2420 3680 4610 2220 2420 3810 4610 2220 2420 4100 5610 2220 2430 5140 5610 2220 2430 5340 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories FOCS / SL Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1542 1742 1942 1962 2442 2642 kW kW 252 111 2,26 3,50 296 128 2,31 3,47 334 149 2,24 3,46 377 164 2,29 3,62 443 183 2,41 3,69 484 199 2,43 3,52 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 86 54 87 55 87 55 87 55 89 56 89 56 4610 2220 2150 3580 4610 2220 2420 3790 5610 2220 2430 3960 5610 2220 2430 4410 6610 2220 2430 5730 6610 2220 2430 5970 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1542-2642 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1500 1500 2000 99 Hydronic - chiller FOCS 1502÷8404 Versions B LN SL base version low noise version super-low noise version Configurations D R base function partial condensing heat recovery function total condensing heat recovery function Features Chiller, air source for outdoor installation FLEXIBILITY Flexibility in applications thanks to the many available functions and versions ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic EXTENSIVE RANGE OF OPERATION Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C. INTEGRATED HYDRONIC MODULE It consists of 2 pumps, 2 or 4-pole motor, fixed or variable speed, with high or low head options to satisfy different industrial applications and demands for comfort. 294 - 1744 kW Unit Description Main accessories Outdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. UÊSoft start UÊCompressor power factor device UÊElectronic expansion valve UÊVariable speed condensation control (standard on /LN, /SL) UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊHydronic group UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit. 100 SHELL & TUBES r HFC R-134a SCREW AXIAL COOLING FOCS / B Models 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 3152 3602 294 101 2,91 3,86 328 120 2,73 3,75 364 133 2,72 3,74 414 146 2,82 3,85 439 156 2,80 3,84 480 160 3 3,88 529 184 2,86 3,76 562 195 2,88 3,88 598 207 2,88 3,98 625 217 2,88 3,89 681 221 3,08 4,07 730 259 2,82 3,94 785 289 2,72 3,94 305 98 82 340 116 99 378 129 109 429 143 121 456 151 129 498 155 130 549 179 152 583 189 161 621 201 172 648 210 178 707 215 182 757 252 217 814 280 243 301 89 385 349 102 445 381 118 492 425 127 545 450 135 577 481 136 609 547 162 699 581 171 741 625 180 793 651 182 823 703 186 878 767 219 973 826 252 1063 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 98 66 98 66 99 67 99 67 99 67 99 67 99 67 99 67 99 67 101 69 101 69 101 69 101 69 4000 2260 2430 3760 4000 2260 2430 3790 4000 2260 2430 3880 4900 2260 2430 4360 4900 2260 2430 5050 4900 2260 2430 5560 4900 2260 2430 5560 4900 2260 2430 5660 4900 2260 2430 5770 5800 2260 2430 5940 5800 2260 2430 6270 5800 2260 2430 7360 5800 2260 2430 8040 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models 3902 4202 4212 4222 4822 5702 6002 6022 6903 7203 7223 8404 831 302 2,75 3,78 900 321 2,80 3,79 972 334 2,91 3,78 1039 346 3 3,90 1156 384 3,01 4,14 1213 423 2,87 3,99 1251 441 2,83 3,85 1338 473 2,83 3,99 1433 519 2,76 3,68 1485 536 2,77 3,82 1608 593 2,71 3,79 1744 643 2,71 3,66 862 292 251 934 311 269 1008 323 272 1078 335 283 1200 372 317 1259 409 351 1298 427 368 1388 458 391 1487 504 419 1541 519 433 1669 574 484 1809 622 529 868 262 1115 948 279 1211 993 283 1260 1056 295 1333 1179 334 1494 1267 368 1613 1320 379 1676 1382 408 1766 1490 439 1903 1544 453 1970 1659 493 2123 1861 556 2383 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 4/4 102 69 102 69 103 70 103 70 104 71 105 72 105 72 105 72 105 72 105 72 105 72 105 72 7000 2260 2430 8470 7000 2260 2430 8610 9400 2260 2430 9430 9400 2260 2430 9690 9400 2260 2430 10110 9400 2260 2430 * 9400 2260 2430 * 11200 2260 2430 * 11200 2260 2430 12390 11200 2260 2430 12530 11200 2260 2430 12670 11200 2260 2430 16360 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 101 FOCS / LN Models 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 3152 3602 287 101 2,84 4,02 318 120 2,65 3,81 354 134 2,64 3,87 405 14 28,9 4 430 159 2,70 3,96 470 163 2,88 4,03 512 186 2,75 3,81 546 197 2,77 3,95 582 210 2,77 4,04 611 219 2,79 4,02 664 228 2,91 4,17 706 268 2,63 3,96 769 291 2,64 4,01 298 97,2 85,2 330 111 116 367 122 129 420 137 144 446 154 136 488 157 138 531 172 180 566 190 168 604 203 180 634 212 187 689 220 194 733 259 230 798 281 250 301 89,1 384 349 102 445 381 118 492 425 127 545 450 135 577 481 136 609 547 162 699 581 171 742 625 180 793 651 183 823 703 186 878 767 219 973 826 252 1063 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 92 60 92 60 93 61 93 61 93 61 93 61 93 61 93 61 93 61 95 63 95 63 95 63 95 63 4000 2260 2430 3800 4000 2260 2430 3830 4000 2260 2430 3920 4900 2260 2430 4410 4900 2260 2430 5090 4900 2260 2430 5630 4900 2260 2430 5630 4900 2260 2430 5730 4900 2260 2430 5840 5800 2260 2430 6010 5800 2260 2430 6340 5800 2260 2430 7330 5800 2260 2430 7900 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models 3902 4202 4212 4222 4822 5702 6002 6022 6903 7203 7223 8404 808 305 2,65 3,83 872 325 2,68 3,81 950 334 2,84 3,91 1014 352 2,88 4 1130 393 2,88 4,27 1177 427 2,75 3,99 1212 448 2,71 3,91 1302 481 2,71 4,11 1367 532 2,57 3,74 1421 549 2,59 3,90 1568 608 2,58 3,93 1679 650 2,58 3,69 838 295 262 904 314 280 986 323 283 1052 340 299 1173 380 336 1221 413 366 1258 432 384 1351 465 411 1419 515 449 1475 530 464 1627 588 517 1742 628 554 868 262 1114 949 279 1211 993 284 1260 1056 295 1334 1180 334 1494 1267 368 1613 1320 379 1676 1382 408 1766 1490 440 1903 1544 453 1970 1659 493 2123 1861 556 2383 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 4/4 96 63 96 63 97 64 97 64 98 65 99 66 99 66 99 66 99 66 99 66 99 66 99 66 7000 2260 2430 8550 7000 2260 2430 8700 9400 2260 2430 9530 9400 2260 2430 9800 9400 2260 2430 10210 9400 2260 2430 * 9400 2260 2430 * 11200 2260 2430 * 11200 2260 2430 12560 11200 2260 2430 12690 11200 2260 2430 12830 11200 2260 2430 16110 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 102 FOCS / SL Models 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 3152 3602 275 105 2,62 3,85 300 127 2,36 3,58 337 140 2,41 3,70 389 159 2,45 3,83 413 171 2,42 3,78 454 174 2,61 3,87 486 197 2,47 3,60 520 208 2,50 3,75 554 223 2,48 3,82 586 234 2,50 3,84 638 247 2,58 3,96 669 290 2,31 3,70 726 312 2,33 3,73 285 102 90,1 311 122 109 349 136 120 404 153 137 429 165 148 471 168 149 504 190 169 539 201 180 575 216 193 608 226 202 662 239 213 694 280 251 753 301 271 301 89,1 385 349 102 445 381 118 492 425 127 545 450 135 577 481 136 609 547 162 699 581 171 742 625 180 793 651 183 823 703 186 878 767 219 973 826 252 1063 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 87 55 87 55 88 56 88 56 88 56 89 57 89 57 89 57 89 57 90 58 90 58 90 58 90 58 4000 2260 2430 3850 4000 2260 2430 3880 4000 2260 2430 3970 4900 2260 2430 4460 4900 2260 2430 5170 4900 2260 2430 5700 4900 2260 2430 5700 4900 2260 2430 5800 4900 2260 2430 5920 5800 2260 2430 6080 5800 2260 2430 6410 5800 2260 2430 7410 5800 2260 2430 8000 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models 3902 4202 4212 4222 4822 5702 6002 6022 6903 7203 7223 8404 768 323 2,38 3,61 822 346 2,38 3,56 909 354 2,57 3,73 975 376 2,59 3,81 1088 426 2,55 4,08 1150 439 2,62 3,69 1185 460 2,57 3,63 1279 491 2,61 3,88 1307 557 2,35 3,61 1358 577 2,35 3,76 1512 653 2,32 3,80 1590 682 2,33 3,51 797 312 280 852 334 300 943 342 303 1011 363 323 1129 411 368 1194 424 377 1229 445 369 1327 475 424 1357 538 478 1410 558 496 1569 631 564 1650 659 590 868 262 1115 949 279 1211 993 284 1260 1056 295 1334 1180 334 1494 1267 368 1613 1320 379 1676 1382 408 1766 1490 440 1903 1544 453 266 1659 493 286 1861 556 320 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 4/4 91 58 91 58 92 59 92 59 93 60 94 61 94 61 94 61 94 61 94 61 94 61 95 62 7000 2260 2430 8640 7000 2260 2430 8790 9400 2260 2430 9620 9400 2260 2430 9890 9400 2260 2430 10300 11200 2260 2430 * 11200 2260 2430 * 11200 2260 2430 * 11200 2260 2430 12690 11200 2260 2430 12830 11200 2260 2430 12970 11200 2260 2430 16290 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1502-8404 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 H A B 103 Hydronic - chiller FOCS-XL 1502÷6002 Versions XL extremely low noise version Features EXTREMELY SILENT OPERATION As result of a sistematic design oriented to minimize the noise level, XL version´s units give the best compromise between silence and efficiency on the market. ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic EXTENSIVE RANGE OF OPERATION Extensive range of operation: full load is granted up to 46°C and in partialization even over 50°C of external air temperature. INTEGRATED HYDRONIC MODULE It consists of 2 pumps, 4-pole motor, fixed or variable speed, with high or low head options to satisfy different industrial applications and demands for comfort. Main accessories Chiller, air source for outdoor installation 272 - 1180 kW Unit Description Outdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit. 104 UÊElectronic expansion valve UÊSoft start UÊRemote keyboard UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board. UÊHydronic group UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation SHELL & TUBES r HFC R-134a SCREW AXIAL COOLING FOCS-XL / XL Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 1502 1702 1902 2002 2402 2602 2702 3202 3602 4202 4802 5402 6002 kW kW 272 105 2,59 4,15 310 123 2,52 3,94 348 137 2,53 4,11 391 143 2,74 4,19 456 169 2,69 4,21 488 192 2,54 3,92 550 227 2,43 3,89 645 254 2,54 3,98 737 313 2,36 4,07 861 332 2,59 3,94 952 363 2,63 4,24 1079 411 2,63 3,76 1180 471 2,51 3,56 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 82 50 82 50 83 51 84 52 85 53 85 53 85 53 85 52 85 52 86 53 87 54 90 57 91 58 4900 2260 2500 4420 4900 2260 2500 4450 4900 2260 2500 4540 5800 2260 2500 6020 5800 2260 2500 6170 5800 2260 2500 6230 5800 2260 2500 6350 7000 2260 2500 8000 7000 2260 2500 8640 9900 2260 2500 9710 11700 2260 2500 10460 11700 2260 2500 10720 11700 2260 2500 10730 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1502-6002 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 105 Hydronic - chiller FOCS-CA 1502÷5424 Versions B LN SL base version low noise version super-low noise version Configurations D R base function partial condensing heat recovery function total condensing heat recovery function Features High efficiency chiller, air source for outdoor installation 310 - 1381 kW FLEXIBILITY Flexibility in applications thanks to the many available configurations and versions ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic HIGH EFFICIENCY Unit in Class A as per Eurovent. High efficiency for low energy consumption during the operating hours EXTENSIVE RANGE OF OPERATION Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C. INTEGRATED HYDRONIC MODULE It consists of 2 pumps, 2 or 4-pole motor, fixed or variable speed, with high or low head options to satisfy different industrial applications and demands for comfort. Unit Description Outdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit. 106 Main accessories UÊSoft start UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation UÊCompressor power factor device UÊElectronic expansion valve UÊVariable speed condensation control (standard on /LN, /SL) UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊHydronic group ENERGY CLASS SHELL & TUBES r HFC R-134a SCREW AXIAL COOLING FOCS-CA / B Models 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 310 95,4 3,25 4,15 358 110 3,23 4,07 406 128 3,15 3,95 441 140 3,15 4 468 147 3,18 4,02 493 156 3,16 4,02 558 176 3,17 4,02 593 187 3,17 4,04 641 202 3,17 4,17 666 208 3,20 4,18 691 215 3,21 4,18 321 92,3 77,4 372 107 88,3 421 125 103 458 135 112 485 143 119 511 151 127 579 170 144 616 181 152 665 195 164 691 201 170 716 208 176 303 86,6 385 349 99 442 396 115 504 436 124 552 463 132 586 489 136 617 554 158 702 589 166 745 647 176 813 676 178 844 703 181 873 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 97 65 97 65 98 66 98 66 98 66 98 66 98 66 99 67 99 67 99 67 99 67 4900 2260 2430 4170 4900 2260 2430 4250 4900 2260 2430 4590 4900 2260 2430 4670 4900 2260 2430 5340 4900 2260 2430 5750 5800 2260 2430 6060 5800 2260 2430 6140 5800 2260 2430 6340 5800 2260 2430 6400 5800 2260 2430 6430 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models 3152 3602 3902 4202 4212 4802 4822 5403 5414 5424 780 245 3,18 4,21 849 272 3,12 4,15 924 288 3,20 4,04 963 302 3,18 3,97 1037 314 3,30 4,01 1088 338 3,21 4,20 1187 365 3,25 4,19 1261 405 3,11 4,21 1332 416 3,20 4,18 1381 428 3,22 4,18 809 237 200 881 263 225 959 280 232 999 294 245 1076 304 249 1130 329 272 1232 353 295 1309 389 327 1382 402 340 1433 415 352 786 213 987 849 246 1080 911 257 1152 948 271 1203 1008 284 1275 1086 305 1373 1179 334 1494 1256 368 1602 1353 357 1688 1407 361 1746 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 4/4 4/4 100 67 100 67 102 69 102 69 102 69 102 69 102 69 103 70 103 70 103 70 7000 2260 2430 7860 7000 2260 2430 8660 9400 2260 2430 9690 9400 2260 2430 9920 11200 2260 2430 10440 11200 2260 2430 10280 11200 2260 2430 10710 11200 2260 2430 12180 11200 2260 2430 12790 11200 2260 2430 12860 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 107 FOCS-CA / LN Models 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 304 94,1 3,23 4,35 351 109 3,22 4,28 397 126 3,13 4,19 433 138 3,12 4,24 460 146 3,13 4,24 484 157 3,08 4,19 545 175 3,11 4,15 579 186 3,10 4,20 625 202 3,09 4,32 651 210 3,10 4,32 676 218 3,10 4,32 315 91,1 79,6 364 105 90,8 412 123 106 449 135 117 477 142 124 502 152 133 566 170 149 601 180 157 648 196 171 675 203 178 702 211 186 303 86,6 385 349 99 442 396 115 504 436 124 553 463 132 586 489 139 620 554 158 702 589 166 745 647 176 813 677 178 844 703 181 873 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 91 59 91 59 92 60 92 60 92 60 92 60 92 60 93 61 93 61 93 61 93 61 4900 2260 2430 4200 4900 2260 2430 4290 4900 2260 2430 4670 4900 2260 2430 4740 4900 2260 2430 5410 4900 2260 2430 5820 5800 2260 2430 6130 5800 2260 2430 6210 5800 2260 2430 6420 5800 2260 2430 6470 5800 2260 2430 6500 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models 3152 3602 3902 4202 4212 4802 4822 5403 5414 5424 764 245 3,11 4,36 825 275 3 4,33 904 286 3,16 4,24 941 300 3,13 4,12 1019 308 3,30 4,24 1061 337 3,14 4,41 1167 366 3,18 4,42 1240 401 3,09 4,41 1302 420 3,10 4,32 1353 436 3,10 4,31 793 238 209 856 266 235 938 276 240 976 291 253 1055 311 269 1102 327 284 1211 355 309 1287 388 340 1350 406 357 1404 422 371 786 214 987 849 246 1080 911 257 1152 949 271 1203 1007 306 1294 1086 305 1373 1180 334 1494 1256 368 1602 1353 357 1688 1407 361 1746 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 4/4 4/4 94 61 94 61 96 63 96 63 96 63 96 63 96 63 97 64 97 64 97 64 7000 2260 2430 7940 7000 2260 2430 8740 9790 2260 2430 9790 9790 2260 2430 10020 11200 2260 2430 10580 11200 2260 2430 10420 11200 2260 2430 10850 11200 2260 2430 12330 11200 2260 2430 12930 11200 2260 2430 13000 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 108 FOCS-CA / SL Models 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 294 97,7 3,01 4,23 340 111 3,04 4,17 383 131 2,92 4,10 420 145 2,88 4,14 447 155 2,88 4,14 470 167 2,80 4,05 523 184 2,84 3,97 557 194 2,86 4,05 599 213 2,81 4,14 626 222 2,81 4,14 653 234 2,78 4,13 305 94,3 83,4 352 108 95 397 127 111 436 141 124 464 150 132 488 162 143 542 177 158 578 188 167 621 206 183 649 216 192 678 227 202 303 86,6 385 349 99 442 396 115 504 436 124 553 463 132 586 489 139 620 554 158 702 589 166 745 647 176 813 677 178 844 703 181 873 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 87 55 87 55 88 56 88 56 88 56 89 57 89 57 89 57 89 57 90 58 90 58 4900 2260 2430 4250 4900 2260 2430 4350 4900 2260 2430 4720 4900 2260 2430 4790 4900 2260 2430 5480 4900 2260 2430 5900 5800 2260 2430 6200 5800 2260 2430 6280 5800 2260 2430 6490 5800 2260 2430 6540 5800 2260 2430 6570 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models 3152 3602 3902 4202 4212 4802 4822 5403 5414 5424 735 260 2,82 4,17 791 290 2,72 4,12 873 296 2,94 4,11 905 312 2,90 3,98 990 320 3,09 4,15 1022 353 2,89 4,28 1133 390 2,90 4,30 1192 422 2,82 4,23 1252 447 2,80 4,14 1306 469 2,78 4,13 763 252 224 820 281 251 905 287 253 939 302 267 1023 326 286 1060 342 301 1176 377 334 1236 408 362 1299 432 384 1355 454 404 786 214 987 849 246 1080 911 257 1152 949 271 1203 1007 306 1294 1086 305 1373 1180 334 1494 1256 368 1602 1353 357 1688 1407 361 1746 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 4/4 4/4 90 57 90 57 91 58 91 58 92 59 93 60 93 60 94 61 94 61 94 61 7000 2260 2430 8020 7000 2260 2430 8830 9400 2260 2430 9880 9400 2260 2430 10110 11200 2260 2430 10670 11200 2260 2430 10510 11200 2260 2430 10940 11200 2260 2430 12460 11200 2260 2430 13070 11200 2260 2430 13140 COOLING Cooling capacity (1) kW Total power input (1) kW EER ESEER COOLING WITH PARTIAL RECOVERY Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1502-5424 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 H A B 109 Hydronic - chiller i-FOCS 0052÷0082 Versions E SL-E high efficiency version super-low noise, high efficiency version Features High efficiency chiller, air source for outdoor installation 511 - 842 kW Unit Description Outdoor unit for the production of chilled water with inverter driven screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tube evaporator designed by Climaveneta and electronic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation together with the use of inverter technology. The high performances level, especially at partial load, is achieved thanks to the accurate units design and to the use of innovative inverter motors in all key components of the unit (compressors, fans and pumps). Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity by adjustment of the compressor speed. The modulation is based on PID algorithms and referring to the leaving water temperature. This is combined with the management of the compressors status, with two selectable logics (proportional referred to the return temperature or dead band referred to the leaving temperature). As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit. 110 SYSTEM EFFICIENCY The unit is designed as a system: all components, with very high operating efficiency, are synergically regulated using proprietary controls logic, and the unit-system is perfectly integrated with all other Climaveneta units VERY HIGH EFFICIENCY AT PARTIAL LOAD Very high efficiency at partial load thanks to the inverter technology applied on screw compressors. Therefore, operating costs are reduced to a minimum TRUE SILENCE Silence optimized for the most frequent operational conditions, thanks to the accurate structures design, to the use of EC fans (DC brushless) and to the adoption of variable-speed driven compressors HARMONY BETWEEN UNIT AND PLANT Low inrush current and cos(phi) higher than 0.9, permit an easy electrical installation which is not stressed during start-up and with no need of extra devices for power factor correction. The use of inverter allows the unit partialize down to 15%, with consequent lower fluctuations of leaving water temperature Main accessories UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board. UÊRemote keyboard (distance to 200m and to 500m) UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation SHELL & TUBES SCREW EC FAN r HFC R-134a COOLING i-FOCS / E Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0052 0062 0072 0082 kW kW 511 203 * 4,69 670 263 * 4,70 737 294 * 4,74 842 335 * 4,71 N. 2/2 2/2 2/2 2/2 dB(A) dB(A) 97 65 98 66 98 65 99 66 4900 2260 2430 5980 5800 2260 2430 7190 7000 2260 2430 8090 7000 2260 2430 8580 mm mm mm kg Note: 1 Evaporator water (in/out): 15/7°C; Condenser Air (in): 35C° 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories i-FOCS / SL-E Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0052 0062 0072 0082 kW kW 492 204 * 4,70 644 267 * 4,71 712 298 * 4,76 808 343 * 4,72 N. 2/2 2/2 2/2 2/2 dB(A) dB(A) 91 59 92 60 92 59 93 60 4900 2260 2430 6090 5800 2260 2430 7290 7000 2260 2430 8200 7000 2260 2430 8690 mm mm mm kg Note: 1 Evaporator water (in/out): 15/7°C; Condenser Air (in): 35C° 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0052-0082 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 111 Hydronic - chiller TECS2 Vision 2.0 0211÷1154 Versions SL-CA XL-CA SL-CA-E Super Low noise version, Class A of efficiency eXtra Low noise version, Class A of efficiency Super Low noise version, very high efficiency, Class A enhanced Configurations D base function partial condensing heat recovery function Features High efficiency chiller, air source for outdoor installation 220 - 1325 kW Unit Description Outdoor unit for the production of chilled water featuring oil-free centrifugal compressor, with R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tube flooded evaporator and electronic regulation valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation together with the use of inverter technology. The compressor is radically innovative: magnetic bearings and digital rotor speed control allow partial load efficiency levels to be reached that were hither to impossible. Commands W3000 large The controller W3000 large offers the latest control and functions specially developed for these units. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. These resources permit to diirectly act on the unit settings through a multilevel menu, available in several languages. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. For multi-units plants a special device to coordinate and manage all the resources is available as an option; energy metering device is even possible as an option. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Temperature regulation features the continuous capacity modulation, based on PID algorithms referring to water leaving temperature. This is combined with the compressors´ on/off management with a proportional logic on the return water temperature. As option is possible to choose the VPF system control integrated on-board to the units. 112 VERY HIGH EFFICIENCY Very high efficiency at full and partial load, to top market levels, thanks to adopted technological solutions: large capacity modulation and expanded exchanger, offering minimum running costs of the unit in real working conditions. VERSION ´CA-E´ AVAILABLE The version ´CA-E´ is characterized by efficiency beyond the ´Class A´ for Eurovent. The technological choices adopted assure the minimization of operating costs and therefore a quick payback time. EXTREMELY SILENT OPERATION As result of a sistematic design oriented to minimize the noise level, XL version´s units give the best compromise between silence and efficiency on the market. LOW INRUSH CURRENTS Reduced breakaway starting currents thanks to the revolutionary centrifugal compressor Main accessories UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation UÊHydronic group UÊEC fans with electronic DC brushless motor UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards ENERGY CLASS SHELL & TUBES r HFC R-134a CENTRIFUGAL AXIAL COOLING TECS2 Vision 2.0 / SL-CA Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0211 0351 0521 0452 0512 0552 0652 0712 0853 0913 1013 1054 1154 kW kW 233 70,2 3,31 4,77 346 110 3,13 4,72 258 81,1 3,18 4,87 442 138 3,20 5,07 509 161 3,16 5,17 574 174 3,30 5,09 650 208 3,13 5,04 742 225 3,30 5,16 848 269 3,15 5,12 904 286 3,15 5,13 977 310 3,15 5,09 1065 336 3,17 5,06 1183 374 3,17 5,14 N. 1/1 1/1 1/1 2/1 2/1 2/1 2/1 2/1 3/2 3/2 3/2 4/2 4/2 88 56 90 58 88 56 90 58 90 58 91 59 92 60 92 60 93 61 93 61 93 61 94 62 94 62 3100 2260 2430 * 4000 2260 2430 * 3100 2260 2430 * 4900 2260 2430 * 4900 2260 2430 * 5800 2260 2430 * 7000 2260 2430 * 7000 2260 2430 * 8500 2260 2430 * 9700 2260 2430 * 10600 2260 2430 * 11200 2260 2430 * 11500 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories TECS2 Vision 2.0 / XL-CA Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0211 0351 0521 0452 0512 0552 0652 0712 0853 0913 1013 1054 1154 kW kW 220 68,5 3,21 4,75 341 109 3,12 4,84 254 79,8 3,19 4,99 435 136 3,19 5,19 526 166 3,17 5,23 579 173 3,35 5,17 640 206 3,11 5,19 739 226 3,27 5,24 874 279 3,13 5,24 900 290 3,11 5,30 972 312 3,12 5,24 1049 331 3,17 5,19 1174 377 3,11 5,23 N. 1/1 1/1 1/1 2/1 2/1 2/1 2/1 2/1 3/2 3/2 3/2 4/2 4/2 82 50 83 51 82 50 83 51 84 52 85 53 85 53 86 54 86 54 86 54 87 55 87 55 88 56 3100 2260 2430 * 4000 2260 2430 * 3100 2260 2430 * 4900 2260 2430 * 5800 2260 2430 * 7000 2260 2430 * 7000 2260 2430 * 7900 2260 2430 * 9400 2260 2430 * 9700 2260 2430 * 10600 2260 2430 * 11200 2260 2430 * 12400 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories TECS2 Vision 2.0 / SL-CA-E Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0211 0351 0521 0452 0512 0552 0652 0712 0853 0913 1013 1054 1154 kW kW 229 67,1 3,41 5,29 384 113 3,40 5,43 285 81,4 3,50 5,52 455 134 3,41 5,79 527 154 3,41 5,71 590 169 3,50 5,64 703 204 3,45 5,77 796 233 3,41 5,77 902 269 3,35 5,62 969 278 3,48 5,79 1086 317 3,42 5,71 1177 336 3,50 5,87 1324 383 3,46 5,75 N. 1/1 1/1 1/1 2/1 2/1 2/1 2/1 2/1 3/2 3/2 3/2 4/2 4/2 88 56 90 58 88 56 90 58 90 58 91 59 92 60 92 60 93 61 93 61 93 61 94 62 95 63 3100 2260 2430 * 4000 2260 2430 * 3100 2260 2430 * 4900 2260 2430 * 4900 2260 2430 * 5800 2260 2430 * 7000 2260 2430 * 7900 2260 2430 * 8500 2260 2430 * 9700 2260 2430 * 10600 2260 2430 * 11200 2260 2430 * 12400 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0211-1154 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 113 Hydronic - chiller NECS-FC 0152÷1204 Versions B SL base version super-low noise version Configurations NG base function function for free-cooling without use of glycole Features Chiller, air source with free-cooling 41,5 - 377 kW Unit Description External units for the production of chilled water, with Free-Cooling function, fitted with hermetic Scroll compressors, axial fans, braze-welded plate exchanger and thermostat expansion valve in R410A. External panelling in peraluman and base in painted galvanised steel. NECS Free-Cooling, a must when demand is high throughout the year, also during the cold season, therefore. In fact, the greater the difference between the temperature of the chilled water and the temperature of the external air, the greater the advantage of free-cooling. Commands OUTSTANDING VERSATILITY The NECS FC units are available in two separate versions: B (basic), SL (super low noise) in order to fully satisfy special requirements and cope with the most complex installation solutions in both the Industrial Process and the Comfort sectors. ELEVATED ENERGY EFFICIENCY Thanks to the dedicated coils for Free-Cooling, the R-410A optimised scroll compressors and the R-410A refrigerant, the NECS FC units allow an average power saving of 30% compared with standard European consumption. MAXIMUM FLEXIBILITY Flexibility is achieved by the continuous modulation of the capacity provided by the compressors. The threeway modulating valve (optional) on the water side offers improved leaving water temperature control also at low outdoor temperatures. CUSTOMISED CONTROL Customised adjustment constantly guarantees the required temperature of the chilled water whilst fully exploiting all the available resources (compressors, fans and water coils) in relation to the temperature of the external air. This makes it possible to fully use the freecooling system even when external air temperatures are close to zero. INTEGRATED HYDRONIC MODULE It consists of 1 or 2 pumps with 2 or 4-pole motor, with three head options to satisfy different industrial applications and demands for comfort W3000SE Large Main accessories The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features a step-wise regulation, referred to the return water temperature with selectable proportional- or proportional-integral logic. UÊRemote keyboard (distance to 200m and to 500m) UÊCoils with FIN GUARD SILVER treatment UÊAutomatic circuit breakers on loads UÊModulating valve for water temperature control in FreeCooling mode 114 PLATES AXIAL r HFC R-410A SCROLL FREE COOLING COOLING NECS-FC / B Models NECS-FC FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) NECS-FC-NG FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0152 0182 0202 0252 0302 0352 0412 0452 0512 kW kW 43,6 14,1 3,09 51 15,5 3,29 61,9 19,5 3,17 68 22,5 3,02 88,5 28,3 3,13 104 30,9 3,37 115 35,8 3,21 131 41,1 3,19 149 43,8 3,40 kW kW °C 43,3 1,50 1,40 51 1,50 1,10 61,9 4,20 0,80 68 4,20 0 88,5 4,20 -0,80 104 4,20 0,40 115 4,20 -0,70 131 6,30 -0,40 149 6,30 0,20 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 dB(A) dB(A) 87 55 87 55 90 58 90 58 91 59 91 59 92 60 92 60 93 61 mm mm mm kg 2200 920 1780 670 2200 920 1780 710 2602 1104 2175 870 2602 1104 2175 880 2602 1104 2175 1060 3602 1104 2175 1310 3602 1104 2175 1340 3602 1104 2175 1410 4602 1104 2205 1650 kW kW 44,8 14,1 3,18 52,4 15,5 3,38 63,6 19,5 3,26 69,8 22,5 3,10 90,9 28,3 3,21 107 30,9 3,46 118 35,8 3,30 135 41,1 3,28 153 43,8 3,49 kW kW °C 44,8 1,50 -1,60 54,4 1,50 -1,90 63,6 4,20 -2,20 69,8 4,20 -3 90,9 4,20 -3,80 107 4,20 -2,60 118 4,20 -3,70 135 6,30 -3,40 153 6,30 -2,80 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 dB(A) dB(A) 87 55 87 55 90 58 90 58 91 59 91 59 92 60 92 60 93 61 2200 920 1780 710 2200 920 1780 760 2602 1104 2175 920 2602 1104 2175 940 2602 1104 2175 1130 3602 1104 2175 1410 3602 1104 2175 1450 3602 1104 2175 1530 4602 1104 2205 1780 mm mm mm kg Note: 1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations). 2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations). 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 115 Models NECS-FC FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) NECS-FC-NG FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0552 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 166 51,5 3,23 187 59,8 3,12 177 56,4 3,14 207 62,5 3,31 234 73,8 3,17 268 79,9 3,35 293 89,6 3,27 336 102 3,31 377 118 3,19 kW kW °C 166 6,30 -1,10 187 8,40 -1,10 177 8,40 1,60 207 8,40 -0,10 234 12,6 0,30 268 12,6 1,40 293 12,6 0,60 336 12,6 0,50 377 16,8 0,40 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 93 61 94 62 93 61 93 61 94 62 94 62 94 62 95 63 96 64 mm mm mm kg 4602 1104 2205 1680 4602 1104 2205 1740 4110 2220 2150 2200 4110 2220 2150 2330 4110 2220 2150 2510 5110 2220 2150 2880 5110 2220 2150 2940 5110 2220 2430 3260 5110 2220 2430 3400 kW kW 171 51,5 3,32 192 59,8 3,21 182 56,4 3,23 212 62,5 3,40 241 73,8 3,26 275 79,9 3,44 301 89,6 3,36 345 102 3,40 387 118 3,28 kW kW °C 171 6,30 -4,10 192 8,40 -4,10 182 8,40 -1,40 212 8,40 -3,10 241 12,6 -2,70 279 12,6 -1,30 301 12,6 -2,40 345 12,6 -2,50 387 16,8 -2,60 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 93 61 94 62 93 61 93 61 94 62 94 62 94 62 95 63 96 64 4602 1104 2205 1810 4602 1104 2205 1890 4110 2220 2150 2510 4110 2220 2150 2650 4110 2220 2150 2840 5110 2220 2150 3250 5110 2220 2150 3320 5110 2220 2430 3700 5110 2220 2430 3850 mm mm mm kg Note: 1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations). 2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations). 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 116 NECS-FC / SL Models NECS-FC FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) NECS-FC-NG FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0152 0182 0202 0252 0302 0352 0412 0452 0512 kW kW 41,5 14,3 2,90 49,8 16,1 3,09 56,9 19,1 2,98 63,8 21,8 2,93 82,4 28 2,94 97,9 32,3 3,03 112 35,7 3,13 122 41,3 2,96 137 45,8 3 kW kW °C 41,5 0,60 -1,20 49,8 1,50 -1,50 56,9 1,50 -1,10 63,8 1,70 -1,30 82,4 1,70 -1,30 97,9 2,60 -1,20 112 2,60 -0,70 122 2,60 -1,50 137 3,50 -1,60 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 dB(A) dB(A) 77 45 78 46 78 46 79 47 80 48 81 49 81 49 82 50 83 51 mm mm mm kg 2200 920 1780 680 2602 1104 2175 860 2602 1104 2175 920 2602 1104 2175 940 3602 1104 2175 1240 3602 1104 2175 1350 4602 1104 2205 1590 4602 1104 2205 1610 4602 1104 2205 1690 kW kW 42,6 14,3 2,98 51,2 16,1 3,18 58,4 19,1 3,06 65,6 21,8 3,01 86,5 28 3,09 101 32,3 3,11 115 35,7 3,22 126 41,3 3,04 141 45,8 3,08 kW kW °C 42,6 0,60 -4,20 51,2 1,50 -4,50 58,4 1,50 -4,10 65,6 1,70 -4,30 86,5 1,70 -4,30 101 2,60 -4,20 115 2,60 -3,70 126 2,60 -4,50 141 3,40 -4,60 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 dB(A) dB(A) 77 46 78 47 78 47 79 48 80 49 81 50 81 50 82 51 83 52 2200 920 1780 730 2602 1104 2175 910 2602 1104 2175 970 2602 1104 2175 990 3602 1104 2175 1300 3602 1104 2175 1450 4602 1104 2205 1690 4602 1104 2205 1730 4602 1104 2205 1810 mm mm mm kg Note: 1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations). 2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations). 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 117 Models NECS-FC FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) NECS-FC-NG FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0552 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 156 53,3 2,92 179 59,2 3,03 166 57,2 2,91 193 66,2 2,91 216 75,2 2,87 243 83,5 2,91 274 90,3 3,03 313 104 3,01 351 120 2,93 kW kW °C 156 3,50 -1,70 179 4,40 -2,80 166 3,50 -1,60 193 5,20 -1,70 216 5,20 -3,30 243 5,20 -1,60 274 5,20 -2,80 313 5,20 -3 351 6,90 -2,90 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 84 52 85 53 82 50 83 51 83 51 84 52 84 52 85 53 86 54 mm mm mm kg 4602 1277 2350 1920 4602 1277 2350 2000 4110 2220 2150 2280 4110 2220 2150 2410 4110 2220 2150 2580 5110 2220 2150 2880 5110 2220 2150 3040 5110 2220 2430 3380 5110 2220 2430 3520 kW kW 160 53,3 3 184 59,2 3,11 171 57,1 2,99 198 66,2 2,99 221 75,2 2,94 249 83,5 2,99 281 90,3 3,12 322 104 3,09 361 120 3,01 kW kW °C 160 3,50 -4,70 184 4,40 -5,80 178 3,50 -4,60 198 5,20 -4,70 221 4,80 -6,30 249 5,10 -4,60 281 5,20 -5,80 322 5,10 -6 361 6,90 -5,90 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 84 53 85 54 82 50 83 51 83 51 84 52 84 52 85 53 86 54 4602 1277 2350 2060 4602 1277 2350 2150 4110 2200 2150 2590 4110 2200 2150 2730 4110 2200 2150 2910 5110 2200 2150 3250 5110 2200 2150 3420 5110 2200 2430 3820 5110 2200 2430 3970 mm mm mm kg Note: 1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations). 2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations). 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-0612 Switchboard side Switchboard opposite side Condensation coil side Opposite side of cond. coil mm mm mm mm 0604-1204 800 800 1500 800 H 1100 1100 2000 2000 H A B A B 118 119 Hydronic - chiller FOCS-FC 1502÷4822 Versions B SL base version super-low noise version Configurations NG base function function for free-cooling without use of glycole Features RANGE Extended capacity range ENERGY SAVING Energy saving guaranteed by free-cooling, which exploits the low external air temperatures; free-cooling control with optional modulating valve INTEGRATED HYDRONIC MODULE It consists of 1 or 2 pumps, 2 or 4-pole motor, with high or low head options to satisfy different applications Main accessories UÊEC fans with electronic DC brushless motor UÊCompressor power factor device UÊElectronic expansion valve UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊHydronic group Chiller, air source with free-cooling 329 - 1229 kW Unit Description Outdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tube evaporator design by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. This air-cooled range, fitted with FREE-COOLING coils, is for use in civil and industrial installations whenever the need for cooling continues throughout the cold months, or when the external air temperature is lower than the temperature of the liquid returning from the installation. During freecooling operation the fluid is cooled by means of the external air, thus reducing the load on the compressors or even completely substituting them. The necessary cooling capacity is therefore obtained with almost zero energy expenditure (FREECOOLING 100 % = EER 25). Further more the NG configuration complies with applications where the use of ethylene glycol is not desired or permitted. Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. 120 SHELL & TUBES r HFC R-134a SCREW AXIAL FREE COOLING COOLING FOCS-FC / B Models FOCS-FC FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) FOCS-FC/NG FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1502 1702 1902 1922 2022 2602 2702 2722 3602 4202 4212 4222 4822 kW kW 329 96,4 3,41 369 114 3,24 417 136 3,07 454 147 3,09 502 168 2,99 579 191 3,03 636 221 2,88 711 221 3,22 858 298 2,88 994 333 2,98 1076 336 3,20 1126 355 3,17 1229 395 3,11 kW kW °C 329 9,60 1,70 369 9,60 0,70 417 21 1,80 454 21 1,10 502 21 0,10 579 25,2 0,60 636 25,2 -0,50 711 29,4 0,60 858 33,6 0 994 42 0,10 1076 50,4 1,30 1126 50,4 0,90 1229 50,4 0 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 99 67 99 67 99 67 99 67 99 67 101 69 101 69 102 69 102 69 103 70 105 72 105 72 105 72 mm mm mm kg 4000 2500 2260 4810 4000 2500 2260 4810 4900 2500 2260 5310 4900 2500 2260 5630 4900 2500 2260 6590 5800 2500 2260 7170 5800 2500 2260 7190 7000 2500 2260 7940 7900 2500 2260 9670 10000 2500 2260 11500 11800 2500 2260 12530 11800 2500 2260 12600 11800 2500 2260 12660 kW kW 338 104 3,25 379 122 3,11 428 136 3,15 466 148 3,15 516 169 3,05 595 192 3,10 653 222 2,94 730 222 3,29 881 299 2,95 1021 335 3,05 1105 338 3,27 1157 356 3,25 1262 397 3,18 kW kW °C 338 16,8 -1,30 379 16,8 -2,30 428 21 -1,20 466 21 -1,90 516 21 -2,90 595 25,2 -2,40 653 25,2 -3,40 730 29,4 -2,40 881 33,6 -3 1021 42 -2,80 1105 50,4 -1,70 1157 50,4 -2,10 1262 50,4 -3 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 99 67 99 67 99 67 99 67 99 67 101 69 101 69 102 69 102 69 103 70 105 72 105 72 105 72 4000 2260 2500 5130 4000 2260 2500 5130 4900 2260 2500 5710 4900 2260 2500 6030 4900 2260 2500 6970 5800 2260 2500 7630 5800 2260 2500 7700 7000 2260 2500 8440 7900 2260 2500 10410 10000 2260 2500 12130 11800 2260 2500 13330 11800 2260 2500 13580 11800 2260 2500 13640 dB(A) dB(A) dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations). 2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations). 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 121 FOCS-FC / SL Models FOCS-FC FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) FOCS-FC/NG FREE-COOLING OFF Cooling capacity (1) Total power input (1) EER FREE-COOLING ON 100% Cooling capacity (2) Total power input (2) Total Free-Cooling temperature (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1502 1702 1902 1922 2022 2602 2702 2722 3602 4202 4212 4222 4822 kW kW 315 102 3,09 348 122 3,25 398 135 3,35 435 150 3,30 503 161 3,12 548 194 3,22 597 229 3,01 683 229 3,38 808 309 3,01 936 339 3,16 1030 338 3,05 1080 362 3,38 1171 413 3,24 kW kW °C 315 9,60 0,40 348 9,60 -0,50 398 12 0,50 435 12 -0,30 503 14,4 0,20 548 14,4 -0,70 597 14,4 -1,60 683 16,8 -0,80 808 19,2 -1,20 936 24 -1,10 1030 28,8 -0,10 1080 28,8 -0,50 1171 28,8 -1,40 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 92 60 92 60 92 60 92 60 94 62 94 62 94 62 95 62 95 62 95 62 97 64 97 64 97 64 mm mm mm kg 4000 2500 2260 4900 4000 2500 2260 4900 4900 2500 2260 5390 4900 2500 2260 5710 5800 2500 2260 7240 5800 2500 2260 7260 5800 2500 2260 7280 7000 2500 2260 8050 7900 2500 2260 9790 10000 2500 2260 11660 11800 2500 2260 12710 11800 2500 2260 12780 11800 2500 2260 12840 kW kW 323 93 3,15 357 103 2,91 409 123 3,02 447 151 2,96 516 162 3,18 562 195 2,89 613 231 2,70 702 230 3,05 830 310 2,68 961 341 2,82 1058 340 3,11 1109 364 3,05 1203 415 2,90 kW kW °C 323 9,60 -2,65 357 9,60 -3,51 409 12 -2,47 447 12 -3,29 516 14,4 -2,77 562 14,4 -3,68 613 14,4 -4,61 702 16,8 -3,80 830 19,2 -4,18 961 24 -4,12 1058 28,8 -3,12 1109 28,8 -3,53 1203 28,8 -4,38 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 92 60 92 60 92 60 92 60 94 62 94 62 94 62 95 62 95 62 95 62 97 64 97 64 97 64 4000 2260 2500 5210 4000 2260 2500 5210 4900 2260 2500 5790 4900 2260 2500 6110 5800 2260 2500 7600 5800 2260 2500 7720 5800 2260 2500 7790 7000 2260 2500 8550 7900 2260 2500 10530 10000 2260 2500 12290 11800 2260 2500 13510 11800 2260 2500 13760 11800 2260 2500 13820 dB(A) dB(A) dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations). 2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations). 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1502-4822 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 H A B 122 123 Hydronic - chiller NECS-C 0152÷1204 Versions B HT base version high efficiency, high outdoor temperature version Configurations D R base function partial condensing heat recovery function total condensing heat recovery function Features Chiller, air source for indoor installation 37,1 - 325 kW Unit Description Indoor unit for the production of chilled water with hermetic rotary scroll compressors dedicated to the use of R410A, centrifugal fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil Peraluman) and base in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions. Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. 124 REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY The NECS-C units are available with both vertical and horizontal air outflow. The horizontal outflow version is particularly effective in installations where the height of the technical compartment does not allow the traditional vertical outflow HIGH PERFORMANCE CENTRIFUGAL FANS The units are fitted with statically and dynamically balanced double-inlet centrifugal fans coupled by belt and pulleys. Useful static pressure up to 180 Pa. INTEGRATED HYDRONIC MODULE The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head Main accessories UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊRubber anti-vibration mounting kit UÊHorizontal or vertical air outflow PLATES r HFC R-410A SCROLL CENTRIFUGAL COOLING NECS-C / B Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits FANS Fan air flow Max AESP (2) NOISE LEVELS Sound power (3) SIZE A (4) B (4) H (4) Operating weight (4) 0152 0182 0202 0252 0302 0352 0412 0452 0512 kW kW 37,1 15,7 2,67 4,61 43 18,3 2,64 4,30 50,5 20,6 2,72 4,46 57 23,2 2,69 4,35 74,8 30,4 2,65 4,18 86,4 36,8 2,60 3,86 97,9 40,7 2,64 3,88 109 46,8 2,53 3,73 121 51,5 2,54 3,74 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 m3/h Pa 15984 120 18000 120 18000 120 18000 120 20016 120 32004 120 32004 120 33984 120 33984 120 dB(A) 82 85 85 85 87 92 92 93 93 2200 920 1642 670 2200 920 1642 670 2200 920 1642 700 2200 920 1642 720 2200 920 1642 880 2602 1104 1927 1120 2602 1104 1927 1170 2602 1104 1927 1210 2602 1104 1927 1260 0552 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 138 58,3 2,53 4,17 159 67,2 2,59 3,94 152 62,5 2,66 3,86 172 73,1 2,55 3,72 195 83,5 2,57 3,61 222 89,6 2,69 3,97 244 102 2,60 3,77 281 115 2,62 3,88 312 133 2,52 3,74 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 m3/h Pa 33984 120 51012 120 47988 120 51012 120 68004 120 64008 120 68004 120 68004 120 84996 120 dB(A) 93 95 94 95 96 95 96 96 97 3602 1104 1927 1450 3602 1104 1927 1550 3602 1277 1900 1845 3602 1277 1900 1940 4602 1277 2235 2310 4602 1277 2235 2445 4602 1277 2235 2515 4602 1277 2235 2695 5602 1277 2235 2885 mm mm mm kg Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits FANS Fan air flow Max AESP (2) NOISE LEVELS Sound power (3) SIZE A (4) B (4) H (4) Operating weight (4) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Useful pressure to be specified at the time of placing the order. 3 Total sound power of the fans as declared by the manufacturer referred to nominal speed of rotation and useful static head of 120 Pa on delivery side. 4 Unit in standard configuration/execution, without optional accessories 125 NECS-C / HT Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits FANS Fan air flow Max AESP (2) NOISE LEVELS Sound power (3) SIZE A (4) B (4) H (4) Operating weight (4) 0152 0182 0202 0252 0302 0352 0412 0452 0512 kW kW 39 14,9 2,98 4,83 45,5 17,4 2,97 4,48 52,7 20 2,94 4,51 59,4 22,4 2,93 4,42 80 30,6 2,96 3,93 91,5 34,6 2,95 4,01 103 39,8 2,86 3,81 114 44,1 2,83 4,03 130 50,8 2,88 3,78 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 m3/h Pa 15984 19008 19008 19008 32004 32004 33984 33984 51012 dB(A) 82 86 86 86 92 92 93 93 95 2200 920 1642 690 2200 920 1642 710 2200 920 1642 730 2200 920 1642 760 2602 1104 1927 1090 2602 1104 1927 1170 2602 1104 1927 1230 3602 1104 1927 1400 3602 1104 1927 1490 0552 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 148 57,8 2,98 3,97 165 64,6 2,80 3,94 158 61,2 2,85 3,54 183 69 2,96 3,94 203 79,9 2,81 3,67 228 89,1 2,80 3,77 257 99,3 2,86 3,71 296 112 2,88 3,84 325 128 2,74 3,75 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 m3/h Pa 51012 51012 51012 64008 68004 68004 84996 84996 84996 dB(A) 95 95 95 95 96 96 97 97 97 3602 1104 1927 1560 3602 1104 1927 1630 3602 1277 1900 1920 4602 1277 2235 2320 4602 1277 2235 2380 4602 1277 2235 2580 5602 1277 2235 2845 5602 1277 2235 3055 5602 1277 2235 3115 mm mm mm kg Models COOLING Cooling capacity (1) Total power input (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits FANS Fan air flow Max AESP (2) NOISE LEVELS Sound power (3) SIZE A (4) B (4) H (4) Operating weight (4) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Useful pressure to be specified at the time of placing the order. 3 Total sound power of the fans as declared by the manufacturer referred to nominal speed of rotation and useful static head of 120 Pa on delivery side. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-1204 Switchboard side Switchboard opposite side Opposite side of cond. coil Condensation coil side mm mm mm mm 1000 1000 1000 2000 H A B 126 127 Hydronic - chiller NECS-W 0152÷1204 Versions B base version Configurations H base function function with heat pump, reversible on hydraulic side Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY Climaveneta has designed the NECS-W units with a range of integral accessories in mind for operation with total water loss (well, water bed, etc.), dry cooler or cooling tower so as to satisfy all service system and installation requirements. INTEGRATED HYDRONIC MODULE ON COOLER/ CONDENSER SIDE The built-in hydronic module includes the main water circuit components; it is available in various configurations with one or two pumps with high or low head both on the evaporator and the condenser side. INTEGRATED CONDENSATION´S CONTROL The electronics of the units manages the most suitable condensing control for each type of application: pressurecontrolled valve, two or three-way modulating valve and inverter control for the pumps Chiller, water source 43,4 - 371 kW Unit Description Main accessories Water-cooled indoor unit for the production of chilled water with hermetic rotary Scroll compressors, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil-Peraluman) and structure in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit fourcompressor versions. UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊCondensing control device: two or three-way modulating pressure-controlled valve and inverter on pumps UÊWater connections directed upwards (for 2 compressors units only) UÊAcoustical enclosure to reduce the noise emissions. UÊRubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only) Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. 128 r HFC R-410A SCROLL PLATES COOLING HEATING NECS-W / B Models COOLING ONLY Cooling capacity (1) Total power input (1) Condernser heating capacity (1) EER ESEER HEATING ONLY (only -H) Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0152 0182 0202 0252 0262 0302 0352 0412 0452 0512 kW kW 43,4 10,0 52,8 4,34 5,80 50,1 11,3 60,7 4,43 6,00 58,9 13,0 71,2 4,53 6,00 66,4 15,2 80,7 4,37 5,70 72,6 16,6 88,2 4,37 5,60 86,7 19,5 105 4,45 5,70 101 22,7 123 4,46 5,80 115 25,9 139 4,43 5,70 129 28,9 156 4,45 5,80 144 32,2 174 4,46 5,80 kW kW 50,5 12,9 3,91 58,2 14,3 4,07 68,0 16,7 4,07 77,0 19,2 4,01 85,0 21,1 4,03 101 24,7 4,09 117 28,7 4,07 132 32,2 4,10 148 36,0 4,12 165 40,0 4,14 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 dB(A) dB(A) 73 74 74 74 75 76 77 77 78 78 1055 469 1255 290 1055 469 1255 305 1055 469 1255 315 1055 469 1255 325 1055 469 1255 330 1222 873 1496 585 1222 873 1496 605 1222 873 1496 660 1222 873 1496 685 1222 873 1496 740 mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) Condernser heating capacity (1) EER ESEER HEATING ONLY (only -H) Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0552 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 165 36,9 200 4,47 5,90 186 41,6 225 4,48 5,80 174 38,9 211 4,47 5,80 203 45,2 245 4,48 5,90 228 51,6 276 4,42 5,80 258 58,0 312 4,45 5,90 288 64,0 348 4,50 5,90 329 74,0 398 4,44 6,00 371 83,5 450 4,44 5,90 kW kW 190 45,9 4,14 215 51,8 4,14 202 49,2 4,11 234 56,6 4,13 263 64,1 4,10 297 72,1 4,12 332 79,5 4,17 379 91,9 4,13 428 104 4,12 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 79 79 86 87 88 89 90 91 91 1222 873 1496 790 1222 873 1496 830 2227 887 1780 1090 2227 887 1780 1165 2227 887 1780 1245 2227 887 1780 1290 2227 887 1780 1395 2227 887 1780 1500 2227 887 1780 1585 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-0612 Switchboard side Switchboard opposite side Unit’s side mm mm mm 0604-1204 800 600 600 H 1000 1000 1000 H B A B A 129 Hydronic - chiller FOCS-W 0401÷1902 Versions B base version Configurations D H R base function partial condensing heat recovery function function with heat pump, reversible on hydraulic side total condensing heat recovery function Features FLEXIBILITY Flexibility in applications thanks to the many available functions and versions ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic HEAT PUMP OPTION Heat pump function water circuit side reversal Chiller, water source Main accessories 87,0 - 447 kW Unit Description Indoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, thermostatic expansion valve, shell and tube condenser and evaporator. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. 130 UÊCompressor power factor device UÊElectronic expansion valve UÊPressostatic control valve UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board SCREW SHELL & TUBES r HFC R-134a HEATING COOLING FOCS-W / B Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW Condernser heating capacity (1) EER ESEER COOLING WITH PARTIAL RECOVERY (only -D) Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY (only -R) Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW HEATING ONLY (only -H) Heating capacity (4) kW Total power input (4) kW COP COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (5) dB(A) Sound pressure (6) dB(A) SIZE A (7) mm B (7) mm H (7) mm Operating weight (7) kg Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW Condernser heating capacity (1) EER ESEER COOLING WITH PARTIAL RECOVERY (only -D) Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY (only -R) Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW HEATING ONLY (only -H) Heating capacity (4) kW Total power input (4) kW COP COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (5) dB(A) Sound pressure (6) dB(A) SIZE A (7) mm B (7) mm H (7) mm Operating weight (7) kg 0401 0501 0551 0651 0751 0851 0951 87 19,6 107 4,44 5,15 107 24,6 132 4,35 5,32 130 28,1 158 4,63 5,25 147 32,6 180 4,51 5,29 165 37 202 4,46 5,40 198 42,8 241 4,63 5,54 221 49,6 271 4,46 5,42 90,2 18,9 8,50 111 23,6 10,6 135 27,1 12,1 153 31,6 14,1 171 35,6 15,9 205 41,2 18,5 221 49,6 21,4 77,4 23,5 99,5 95,2 29,2 123 116 34,2 148 131 39,2 168 147 44 188 175 51,2 202 197 59,1 252 95,7 23,2 4,13 118 28,9 4,09 142 33,8 4,20 162 38,9 4,16 181 43,4 4,17 215 50,7 4,24 243 58,4 4,16 1/1 1/1 1/1 1/1 1/1 1/1 1/1 91 * 92 * 94 * 94 * 94 * 94 * 94 * 2300 1000 1500 800 2500 1000 1500 840 2500 1000 1500 1160 2500 1000 1500 1180 2500 1000 1500 1190 3200 1500 1200 1270 3200 1500 1200 1350 0802 1002 1102 1302 1502 1702 1902 178 39,4 217 4,52 5,39 217 49,2 266 4,41 5,52 251 55,9 307 4,49 5,24 298 65,6 364 4,54 5,49 340 74,4 414 4,57 5,67 393 85,4 478 4,60 5,70 447 99,6 547 4,49 5,61 184 38 17 217 49,2 21,3 251 55,8 24,1 298 65,6 28,3 340 74,5 32,2 393 85,4 36,9 447 99,5 43 158 47,1 189 194 58,7 249 223 67,9 287 265 78,6 339 304 88,6 387 348 102 445 397 118 509 194 46,6 4,16 239 58 4,12 276 67,2 4,11 326 77,8 4,19 372 87,5 4,25 428 101 4,23 489 116 4,18 2/2 2/2 2/2 2/2 2/2 2/2 2/2 94 * 95 * 97 * 97 * 97 * 97 * 97 * 3200 1500 1200 1470 3200 1500 1200 1490 3200 1500 1200 1930 3500 1200 1800 2220 3500 1200 1800 2260 3500 1200 1800 2320 3500 1200 1800 2720 Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C. 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 7 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0401-1902 Switchboard side Cooler water connections side (minimum) Condenser water connections side Condenser water fittings opposite side (minimum) mm 650 mm 450 mm 900 mm 600 H B A 131 Hydronic - chiller FOCS2-W 1301÷9604 Versions CA Class A of efficiency CA-E Very high efficiency version: Class A enhanced Configurations D H R base function partial condensing heat recovery function function with heat pump, reversible on hydraulic side total condensing heat recovery function Features HIGH EFFICIENCY The version ´CA-E´ is characterized by efficiency beyond the ´Class A´ for Eurovent. The technological choices adopted assure the minimization of operating costs and therefore a quick payback time. ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic HEAT PUMP FUNCTION Heat pump function water circuit side reversal SILENT OPERATION Silent operation thanks to the accurate units design. Optional integral acoustic enclosure, further reduces the sound level beyond the best on market High efficiency chiller, water source 306 - 2416 kW Unit Description Main accessories Unit for indoor installation for chilled water production. Semihermetic screw compressors optimized to operate with low compression ratio and R134a; shell and tubes condenser and direct expansion evaporator; electronic expansion valve. Frame in polyester-painted galvanized steel. High efficiency unit: the innovative optimized compressors and the high performing heat exchangers enhance EER values up to 5,1 (CA version) and even up to 5,6 (CA-E version) at Eurovent standars conditions. UÊKit HWT, High Water Temperature, to produce hot water up to 60°C UÊIntegral acoustical enclosure (type base or plus) UÊVPF (Variable Primary Flow) system UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit. 132 ENERGY CLASS SCREW SHELL & TUBES r HFC R-134a COOLING HEATING FOCS2-W / CA Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW Condernser heating capacity (1) EER ESEER COOLING WITH PARTIAL RECOVERY (only -D) Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY (only -R) Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW HEATING ONLY (only -H) Heating capacity (4) kW Total power input (4) kW COP COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (5) dB(A) Sound pressure (6) dB(A) SIZE A (7) mm B (7) mm H (7) mm Operating weight (7) kg Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW Condernser heating capacity (1) EER ESEER COOLING WITH PARTIAL RECOVERY (only -D) Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW COOLING WITH TOTAL RECOVERY (only -R) Cooling capacity (3) kW Total power input (3) kW Heat recovery capacity (3) kW HEATING ONLY (only -H) Heating capacity (4) kW Total power input (4) kW COP COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (5) dB(A) Sound pressure (6) dB(A) SIZE A (7) mm B (7) mm H (7) mm Operating weight (7) kg 1301 1401 1601 1801 2101 2401 2701 3001 2802 3202 3602 4202 306 60,5 5,06 348 68,7 5,07 422 83,4 5,06 477 94,4 5,06 538 106 5,07 607 120 5,07 689 136 5,06 735 145 5,06 694 137 5,05 844 167 5,06 957 189 5,07 1071 212 5,06 318 58,4 26,3 361 66,3 29,8 438 80,5 36,2 495 91,1 41 558 102 46 630 116 52 715 131 59,1 762 140 63,1 720 133 59,7 876 161 72,4 993 182 82 1112 204 91,9 276 76,8 348 314 87,3 396 376 104 474 425 118 536 483 133 608 546 150 687 603 166 759 667 183 839 625 175 790 752 209 948 853 236 105 964 265 1214 348 76,8 4,53 396 87,3 4,54 474 104 4,54 536 118 4,54 608 133 4,58 687 150 4,59 759 166 4,58 839 183 4,59 790 175 4,52 948 209 4,54 1075 236 4,55 1214 265 4,58 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 97 75 97 75 97 75 97 75 97 75 97 75 99 77 99 77 99 77 99 77 99 77 99 77 3930 900 1850 * 3930 900 1850 * 3930 900 1900 * 3930 900 1950 * 3930 900 1950 * 3930 900 1950 * 3980 900 1990 * 3980 900 1990 * 4250 1150 2160 * 4750 1150 2156 * 4750 1150 2156 * 4750 1150 2226 * 4502 4802 5402 6002 6303 6603 7203 7803 8103 9003 9004 9604 1145 226 5,06 1213 240 5,06 1376 272 5,05 1467 290 5,05 1604 317 5,05 1677 331 5,06 1815 359 5,05 1977 391 5,06 2069 409 5,06 2201 435 5,06 2278 451 5,05 2416 478 5,05 1188 218 98,2 1259 231 104 1428 263 118 1522 280 126 1664 306 138 1740 320 144 1883 346 156 2051 377 170 2146 394 178 2283 420 189 2363 435 196 2507 462 208 1029 283 1295 1091 300 1374 1205 331 1516 1333 366 1676 1295 283 4,58 1374 300 4,58 1516 331 4,58 1676 366 4,58 1817 398 4,57 1898 415 4,58 2056 449 4,58 2215 484 4,58 2276 497 4,58 2515 548 4,59 2582 564 4,58 2739 599 4,58 2/2 2/2 2/2 2/2 3/3 3/3 3/3 3/3 3/3 3/3 4/4 4/4 99 77 99 77 101 79 101 79 102 80 102 80 102 80 102 80 102 80 102 80 102 80 102 80 4750 1150 2226 * 4750 1150 2226 * 4850 1150 2226 * 4850 1150 2226 * 4950 1700 2150 * 4950 1700 2150 * 4950 1700 2150 * 4950 1700 2150 * 4950 1700 2150 * 4950 1700 2150 * 4650 2250 2180 * 4650 2250 2180 * Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C. 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 7 Unit in standard configuration/execution, without optional accessories 133 FOCS2-W / CA-E Models 1301 COOLING ONLY Cooling capacity (1) kW 321 Total power input (1) kW 57,3 Condernser heating capacity (1) EER 5,60 ESEER 6,49 COOLING WITH PARTIAL RECOVERY (only -D) Cooling capacity (2) kW 322 Total power input (2) kW 57,2 Desuperheater heating capacity (2) kW 25,7 COOLING WITH TOTAL RECOVERY (only -R) Cooling capacity (3) kW 289 Total power input (3) kW 73,1 Heat recovery capacity (3) kW 357 HEATING ONLY (only -H) Heating capacity (4) kW 357 Total power input (4) kW 73,1 COP 4,89 COMPRESSORS No. Compressors/No. Circuits N. 1/1 NOISE LEVELS Sound power (5) dB(A) 97 Sound pressure (6) dB(A) 75 SIZE A (7) mm 4300 B (7) mm 990 H (7) mm 1900 Operating weight (7) kg * 1401 1601 1801 2101 2401 2802 3202 3602 4202 4802 365 65,1 5,60 6,50 442 79,1 5,59 6,30 506 90,3 5,61 6,40 574 103 5,59 6,37 649 116 5,59 6,40 729 130 5,60 6,66 884 158 5,59 6,57 1012 180 5,61 6,73 1147 205 5,59 6,64 1298 232 5,59 6,66 367 65,0 29,2 444 78,9 35,5 509 90,1 40,5 577 102 46,1 653 116 52,2 733 130 58,5 889 158 71,0 1017 180 81,0 1153 205 92,1 1305 232 104 328 83,1 407 395 99,5 488 452 114 559 657 166 813 790 199 977 904 227 1118 407 83,1 4,89 488 99,5 4,91 559 114 4,92 638 129 4,94 722 146 4,94 813 166 4,89 977 199 4,91 1118 227 4,92 1275 258 4,94 1443 292 4,94 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 97 75 97 75 97 75 97 75 97 75 99 77 99 77 99 77 99 77 99 77 4300 990 1900 * 4000 990 2000 * 4000 990 2000 * 4000 990 2000 * 4300 990 2100 * 4600 1240 2195 * 4950 1240 2195 * 5220 1240 2195 * 4950 1240 2350 * 4950 1375 2430 * Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C. 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 7 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1301-9604 Switchboard side Cooler water connections side (minimum) Condenser water connections side Condenser water fittings opposite side (minimum) mm mm mm mm 1500 900 3000 1500 134 135 Hydronic - chiller TECS2-W Vision 2.0 0251÷1954 Versions HC LC High Condensing Low Condensing Configurations H base function function with heat pump, reversible on hydraulic side Features VERY HIGH EFFICIENCY Very high efficiency at full and partial load, to top market levels, thanks to adopted technological solutions: large capacity modulation and expanded exchanger, offering minimum running costs of the unit in real working conditions. DEDICATED VERSIONS Dedicated versions for different applications: version HC, High Condensing, for dry-cooler or heat pump systems and version LC, Low Condensing, for cooling tower or ground source applications. HEAT PUMP FUNCTION Heat pump function water circuit side reversal EXTREMELY SILENT OPERATION Extremely silent operation in line with the best on the market, and highly reduced vibrations LOW INRUSH CURRENTS Reduced breakaway starting currents thanks to the revolutionary centrifugal compressor High efficiency chiller, water source 241 - 1949 kW Unit Description Main accessories Indoor unit for the production of chilled water featuring centrifugal compressors oil-free, with R134a, electronic regulation valve, shell and tube condenser and shell and tube flooded evaporator. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation together with the use of inverter technology. The compressor is radically innovative: magnetic bearings and digital rotor speed control allow partial load efficiency levels to be reached that were hither to impossible. UÊIntegral acoustical enclosure (type base or plus) UÊVPF (Variable Primary Flow) system UÊSeveral devices for condensation´s control UÊLeak detector UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity by adjustment of the compressor speed. The modulation is based on PID algorithms and referring to the leaving water temperature. This is combined with the management of the compressors status, based on a proportional logic referred to the return temperature. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit. 136 ENERGY CLASS r HFC R-134a CENTRIFUGAL SHELL & TUBES COOLING HEATING TECS2-W Vision 2.0 / HC Models COOLING ONLY Cooling capacity (1) Total power input (1) Condernser heating capacity (1) EER ESEER HEATING ONLY (only -H) Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0251 0311 0351 0411 0512 0612 0712 0812 0913 1053 1213 1414 1614 kW kW 241 46 5,24 8,70 294 57 5,15 8,83 359 69,2 5,19 8,84 405 78,9 5,13 8,95 497 94,8 5,24 9,08 588 114 5,16 9,16 716 139 5,14 9,04 811 156 5,14 9,21 881 171 5,15 9,13 1045 203 5,15 8,96 1213 237 5,12 9,12 1405 269 5,23 9,16 1618 316 5,13 9,20 kW kW 287 57 5,00 351 70 5,01 439 89 4,95 500 101 4,93 592 118 5,01 703 140 5,02 877 178 4,92 1000 203 4,94 1053 210 5,02 1279 261 4,91 1496 304 4,92 1718 346 4,96 1995 405 4,92 N. 1/1 1/1 1/1 1/1 2/1 2/1 2/1 2/1 3/1 3/1 3/1 4/1 4/1 91 59 93 61 92 60 94 62 94 62 95 63 94 62 96 64 96 64 96 64 97 65 97 65 98 66 2990 950 1900 - 2990 950 1900 - 2990 950 1900 - 2990 950 1900 - 3490 1300 1800 - 3490 1300 1800 - 3490 1300 1800 - 3490 1300 1800 - 4990 1300 1800 - 4990 1300 1800 - 4990 1300 1800 - 5450 1300 1990 - 5450 1300 1990 - dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 5 Unit in standard configuration/execution, without optional accessories TECS2-W Vision 2.0 / LC Models COOLING ONLY Cooling capacity (1) Total power input (1) Condernser heating capacity (1) EER ESEER COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A (4) B (4) H (4) Operating weight (4) 0511 0912 1012 1353 1453 1854 1954 kW kW 488 93,2 5,24 9,37 879 172 5,12 9,19 978 186 5,24 9,45 1359 258 5,27 9,43 1461 280 5,22 9,41 1809 344 5,26 9,52 1949 373 5,23 9,42 N. 1/1 2/1 2/1 3/1 3/1 4/1 4/1 95 63 96 64 97 65 97 65 98 66 99 67 99 67 2990 950 1900 - 3490 1300 1800 - 3490 1300 1800 - 4990 1300 1800 - 4990 1300 1800 - 5450 1300 1990 - 5450 1300 1990 - dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required Switchboard side Cooler water connections side (minimum) Condenser water connections side Raising points side 0251-0411 0512-0612 0712-1213 1414-1614 mm 1000 1000 1000 1000 mm 2500 3000 4000 4500 mm mm 2500 900 3000 900 4000 900 4500 900 137 Hydronic - chiller NECS-ME 0152÷1604 Versions B base version Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) UNIT DESIGNED FOR COMBINATION WITH REMOTE CONDENSER Compact units, designed for residential- and commercial air-conditioning systems INTEGRAL CONTROL AND ADJUSTMENT The condenserless unit comes complete with built-in microprocessor control with possible connection to the condenser. INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or double pump configuration, with low or high head. Main accessories UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊAcoustical enclosure to reduce the noise emissions. UÊRubber anti-vibration mounting kit Condenserless chiller 39,5 - 432 kW Unit Description Indoor unit for the production of chilled water that may be connected to a remote condenser with hermetic rotary scroll compressors working with R410A, braze-welded plate-type exchanger and thermal expansion valve. Panels and base in hot-dip galvanised sheet steel with paint finish. Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. 138 r HFC R-410A SCROLL PLATES COOLING NECS-ME / B Models COOLING Cooling capacity (1) Compressors power input (1) Remote condenser capacity (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0152 0182 0202 0252 0262 0302 0352 0412 0452 0512 0552 kW kW kW 39,5 12 3,29 45,8 13,5 3,39 53,6 15,7 3,41 60,5 18,1 3,34 67,4 20 3,37 80,2 23,4 3,43 92,8 26,9 3,45 105 30,3 3,45 117 33,9 3,46 131 37,6 3,49 151 43,3 3,48 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 73 41 74 42 74 42 74 42 75 43 76 44 77 45 77 45 77 45 78 46 79 47 1130 669 1255 270 1130 669 1255 280 1130 669 1255 290 1130 669 1255 295 1130 669 1255 300 1310 893 1496 410 1310 893 1496 500 1310 893 1496 585 1310 893 1496 615 1310 893 1496 645 1310 893 1496 680 dB(A) dB(A) mm mm mm kg Models COOLING Cooling capacity (1) Compressors power input (1) Remote condenser capacity (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0612 0604 0704 0804 0904 1004 1104 1204 1404 1604 kW kW kW 170 48,9 3,47 161 46,9 3,43 186 53,7 3,46 207 60,6 3,42 235 67,9 3,47 263 75,2 3,50 301 86,5 3,47 339 97,8 3,47 387 111 3,49 432 124 3,48 N. 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 79 47 86 54 87 55 88 56 89 57 90 58 91 59 91 59 91 59 91 59 1310 893 1496 755 2227 1020 1780 700 2227 1020 1780 950 2227 1020 1780 1125 2227 1020 1780 1185 2227 1020 1780 1250 2227 1020 1780 1330 2227 1020 1780 1370 2227 1020 1780 1430 2227 1020 1780 1480 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condensation temperature = 47°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base. Minimum clearance required 0152-0612 Switchboard side Cooler water connections side (minimum) Unit's side Switchboard opposite side mm mm mm mm H 800 600 600 600 0604-1604 1000 1000 800 1000 H B A B A 139 Hydronic - chiller FOCS-ME 0401÷1902 Versions B base version Features COMPACTNESS Compactness in terms of overall size and weight, helping installation and working on site ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic EXTENSIVE RANGE OF OPERATION Extensive range of operation with remote condenser operating up to 46°C air temperature SILENT OPERATION Silent operation thanks to the accurate units design. Optional integral acoustic enclosure, further reduces the sound level beyond the best on market Main accessories UÊSoft start UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board. UÊRemote keyboard (distance to 200m and to 500m) UÊElectronic expansion valve UÊIntegral acoustical enclosure (type base or plus) Condenserless chiller 79,2 - 410 kW Unit Description Indoor unit for the production of chilled water combined with a remote condenser, with semi-hermetic screw compressors optimized for R134a, shell and tube evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. Commands W3000SE Compact The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. 140 SHELL & TUBES SCREW r HFC R-134a COOLING FOCS-ME / B Models COOLING Cooling capacity (1) Compressors power input (1) Remote condenser capacity (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0401 0501 0551 0651 0751 0851 0951 kW kW kW 79,2 22,7 102 98,2 27,9 126 119 32,5 152 135 37,6 173 151 42,3 193 181 48,9 230 203 56,5 260 N. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 dB(A) dB(A) 91 92 94 94 94 94 94 2024 880 1300 720 2330 880 1300 750 2400 880 1490 1040 2400 880 1490 1060 2400 880 1490 1060 2947 880 1490 1130 2947 880 1500 1150 0802 1002 1102 1302 1502 1702 1902 kW kW kW 162 45,6 208 200 56,0 256 230 64,6 295 273 75,3 348 312 85,0 397 360 97,7 458 410 113 523 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 94 95 97 97 97 97 97 2890 1081 1430 1280 2890 1081 1430 1290 3016 1081 1480 1680 3277 1081 1580 1970 3277 1081 1580 1990 3292 1081 1590 2010 3362 1081 1700 2300 mm mm mm kg Models COOLING Cooling capacity (1) Compressors power input (1) Remote condenser capacity (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condensation temperature = 47°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. Minimum clearance required 0401-1902 Switchboard side Cooler water connections side (minimum) Compressor outlet connection side Compressor outlet connection opposite side mm 1000 mm 620 mm 500 mm 500 H B A 141 Hydronic - chiller FOCS-ME 1001÷9604 Versions B base version Features COMPACTNESS Compactness in terms of overall size and weight, helping installation and working on site ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic EXTENSIVE RANGE OF OPERATION Extensive range of operation with remote condenser operating up to 46°C air temperature SILENT OPERATION Silent operation thanks to the accurate units design. Optional integral acoustic enclosure, further reduces the sound level beyond the best on market Main accessories UÊIntegral acoustical enclosure (type base or plus) UÊElectronic expansion valve UÊSoft start UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board. UÊRemote keyboard (distance to 200m and to 500m) Condenserless chiller 219 - 2240 kW Unit Description Indoor unit for the production of chilled water combined with a remote condenser, with semi-hermetic screw compressors optimized for R134a, shell and tube evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. Commands W3000SE Compact The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. 142 r HFC R-134a SCREW SHELL & TUBES COOLING FOCS-ME / B Models COOLING Cooling capacity (1) Compressors power input (1) Remote condenser capacity (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 1001 1201 1301 1351 1601 1801 2002 2402 2602 kW kW kW 219 59,7 279 262 69,7 332 295 77,5 373 333 85,4 418 389 101 490 445 118 563 419 114 533 516 139 655 591 155 746 N. 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 dB(A) dB(A) 94 97 97 97 97 97 97 99 99 2835 900 1800 1380 3120 900 1800 1870 3120 900 1800 1910 3120 900 1800 1920 3530 900 1950 2640 3530 900 1950 2650 3730 1150 2000 2750 3730 1150 2000 3420 4500 1150 2000 3710 2702 3202 3602 4202 4502 4802 5003 5203 5403 kW kW kW 674 171 845 759 202 916 885 236 1121 1000 265 1265 1061 277 1338 1120 290 1410 1184 320 1504 1251 337 1588 1304 353 1657 N. 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 dB(A) dB(A) 99 99 99 99 99 99 101 101 101 4500 1150 2000 3730 4500 1150 2000 4600 4500 1150 2000 5050 4500 1150 2000 5220 4500 1150 2000 5250 4500 1150 2000 5280 4425 1700 1900 6810 4425 1700 1900 6840 4425 1700 1900 6850 5414 5904 6404 6804 7204 7804 8404 9004 9604 kW kW kW 1348 342 1690 1434 373 1807 1548 406 1954 1660 439 2099 1769 472 2241 1886 501 2387 2001 530 2531 2121 555 2676 2240 580 2820 N. 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4 dB(A) dB(A) 102 102 102 102 102 102 102 102 102 mm mm mm kg 4500 2250 2000 7560 4500 2250 2000 8400 4500 2250 2000 9980 4500 2250 2000 10010 4500 2250 2000 10020 4500 2250 2000 10190 4500 2250 2000 10350 4500 2250 2000 10420 4500 2250 2000 10480 mm mm mm kg Models COOLING Cooling capacity (1) Compressors power input (1) Remote condenser capacity (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight mm mm mm kg Models COOLING Cooling capacity (1) Compressors power input (1) Remote condenser capacity (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight Note: 1 Evaporator water (in/out) = 12/7°C; Condensation temperature = 47°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. Minimum clearance required 1001-9604 Switchboard side Cooler water connections side (minimum) Compressor outlet connection side Compressor outlet connection opposite side mm 1000 mm 620 mm 500 mm 500 H A B 143 DR RONIC - R R 144 hydronic reversible EVERSIBLE hydronic - reversible 145 Hydronic - reversible NECS-N 0152÷1204 Versions B HL HT LN SL base version low noise, high efficiency, high outdoor temperature version high efficiency, high outdoor temperature version low noise version super-low noise version Configurations D base function partial condensing heat recovery function Features Reversible unit, air source for outdoor installation 35,8 - 322 kW Unit Description Outdoor unit with heat pump for the production of chilled/hot water with hermetic rotary scroll compressors dedicated to the use of R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil Pereluman) and base in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions. Commands REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY Climaveneta is the only company offering units with Scroll compressors in 5 versions and 2 different configurations designed to satisfy all service system and application requirements STANDARD SUPPLY WITH WATER FILTER ALREADY INSTALLED The water filter is already installed as standard supply on all units, including those without hydronic kit. This simplifies installation procedures, while ensuring maximum working reliability INTEGRATED HYDRONIC MODULE The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank Main accessories W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 146 UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊLT kit for working down to -10°C in heat pump mode UÊRubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only) PLATES SCROLL AXIAL r HFC R-410A COOLING HEATING NECS-N / B Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552 37,7 13,6 2,77 4,04 42,8 15,7 2,73 4,08 47,9 19,2 2,49 4,03 57,5 20,4 2,82 4 72 28 2,57 3,95 82,5 32 2,58 4,06 93,9 36 2,61 3,92 107 39,9 2,68 4,09 120 44 2,73 4,04 138 50,6 2,73 4,18 42,9 14,2 3,02 48,1 15,6 3,08 54,2 18,1 2,99 65,2 21,2 3,08 81 26,1 3,10 93,5 29,8 3,14 105 33,8 3,11 121 38,1 3,18 136 42,4 3,21 157 48,6 3,23 39,1 13,1 11,2 44,4 15,1 13,1 49,7 18,5 16,2 59,7 19,7 16,9 74,7 27,1 23,7 85,6 30,9 27,2 97,4 34,8 30,3 111 38,5 33,8 125 42,5 37 143 48,7 42,7 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 84 52 84 52 84 52 84 52 85 53 86 54 86 54 86 54 87 55 87 55 1695 1120 1420 400 1695 1120 1420 410 1695 1120 1420 420 2195 1120 1420 500 2195 1120 1420 630 2195 1120 1420 690 2745 1120 1420 770 2745 1120 1420 850 3245 1120 1620 950 3245 1120 1620 1020 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204 151 59 2,56 3,99 111 43,7 2,54 3,99 129 54 2,39 3,39 147 60 2,45 3,57 166 68,9 2,41 3,64 189 75,9 2,49 3,80 211 85,1 2,48 3,88 240 95,6 2,51 3,68 277 107 2,58 3,84 311 120 2,58 3,93 173 54,6 3,17 127 43,6 2,91 145 52,7 2,75 167 58 2,88 185 64,7 2,86 209 72,1 2,90 234 79,9 2,93 267 92,1 2,90 306 104 2,94 344 116 2,96 156 56,9 50,3 116 42,5 35,4 134 52,4 40,7 152 58,1 46 172 66,8 54 196 73,4 60,1 219 82,5 68,6 249 92,7 74,1 287 104 84,6 322 117 96,3 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 87 55 91 59 92 60 92 60 92 60 92 60 93 61 94 62 95 63 95 63 3245 1120 1620 1030 3110 2220 1700 1380 3110 2220 1700 1570 3110 2220 1700 1750 3110 2220 2150 1900 3110 2220 2150 2080 4110 2220 2150 2270 4110 2220 2150 2410 4110 2220 2150 2540 4110 2220 2150 2700 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 147 NECS-N / HL Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 113 43,8 2,58 3,75 129 51 2,53 3,81 142 58,9 2,41 3,78 163 67,4 2,42 3,91 190 73,9 2,57 3,79 209 84,6 2,47 3,81 236 92,6 2,55 3,92 273 103 2,63 4,11 307 119 2,57 3,91 128 44,3 2,89 144 49,2 2,93 159 53,9 2,95 181 60,9 2,97 211 71 2,97 233 78,7 2,96 261 86,4 3,02 303 98,7 3,07 340 112 3,01 117 42,3 34,7 133 49,1 41 148 57,1 48,3 169 64,9 55,6 197 71,6 59,6 217 82,2 69,4 245 89,4 76 283 101 86,4 318 116 98,1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 86 54 86 54 86 54 86 54 88 56 88 56 88 56 90 58 91 59 3110 2220 1700 1460 3110 2220 2150 1700 3110 2220 2150 1840 3110 2220 2150 1980 4110 2220 2150 2310 4110 2220 2150 2370 4110 2220 2150 2520 5110 2220 2150 2800 5110 2220 2150 2940 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories NECS-N / HT Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 117 45,5 2,57 3,42 134 51,3 2,61 3,53 149 58,4 2,55 3,64 172 65,7 2,62 3,77 198 75,3 2,63 3,57 219 84,9 2,58 3,60 248 91,5 2,71 3,82 287 102 2,79 3,98 322 118 2,71 3,80 134 48,2 2,78 150 53 2,83 167 58 2,88 191 65,2 2,93 220 76,9 2,86 244 84,7 2,88 274 92,3 2,97 315 104 3,02 357 121 2,95 121 44,1 33 139 49,8 38,3 155 56,8 44,8 178 63,7 51,1 205 73,1 56 228 82,7 64,8 257 88,9 70,6 297 99,6 80,5 334 115 91,2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 92 60 92 60 92 60 92 60 94 62 94 62 94 62 97 64 97 65 3110 2220 1700 1460 3110 2220 2150 1700 3110 2220 2150 1840 3110 2220 2150 1980 4110 2220 2150 2310 4110 2220 2150 2370 4110 2220 2150 2520 5110 2220 2150 2800 5110 2220 2150 2940 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 148 NECS-N / LN Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552 35,8 14,2 2,52 4,09 41,6 16 2,60 4,16 48 19,1 2,51 4,03 54,6 21,4 2,55 4,02 73,2 27,2 2,69 4,08 83,5 31,9 2,62 3,96 93,9 36 2,61 3,94 103 41,5 2,48 3,93 119 44,6 2,67 3,99 132 53,4 2,47 3,97 41,8 13,8 3,02 48,2 15,2 3,17 54,1 18,1 2,99 63,6 20,7 3,07 84,1 26,1 3,22 96,2 30,4 3,16 109 34,2 3,19 121 36,2 3,34 138 42,6 3,24 154 48,3 3,19 37,1 13,8 12,2 43,1 15,5 13,7 49,8 18,4 16,1 56,7 20,6 18,2 75,9 26,3 23,1 86,7 30,9 26,7 97,4 34,8 30,3 107 40,2 35,3 123 43,1 37,5 137 51,6 45,4 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 79 47 79 47 80 48 80 48 81 49 83 51 83 51 83 51 84 52 84 52 1695 1120 1420 400 1695 1120 1420 420 2195 1120 1420 460 2195 1120 1420 500 2745 1120 1420 710 2745 1120 1620 770 2745 1120 1620 830 2745 1120 1620 880 3245 1120 1620 990 3245 1120 1620 1020 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204 143 62,7 2,28 3,76 103 46,2 2,23 3,89 123 53,5 2,30 3,66 141 60 2,35 3,74 156 70,3 2,22 3,78 177 78,3 2,26 3,77 199 87,7 2,27 3,89 227 96,2 2,36 3,76 261 110 2,37 3,92 291 125 2,32 3,86 169 54,2 3,12 122 41,5 2,94 138 48,9 2,82 158 53,7 2,94 176 60,7 2,90 198 67,8 2,92 225 75,5 2,98 254 86,1 2,95 290 98 2,96 324 110 2,94 148 60,6 53,8 107 44,7 39,2 128 51,8 43,5 146 58 49,2 162 68,2 58,7 184 75,9 65,7 207 84,9 74,1 236 93,4 79,7 270 107 92 302 121 105 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 84 52 85 53 86 54 86 54 86 54 86 54 87 55 88 56 89 57 89 57 3245 1120 1620 1030 3110 2220 1700 1380 3110 2220 1700 1570 3110 2220 1700 1750 3110 2220 2150 1900 3110 2220 2150 2080 4110 2220 2150 2270 4110 2220 2150 2410 4110 2220 2150 2540 4110 2220 2150 2700 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 149 NECS-N / SL Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 108 45 2,40 3,84 124 52,1 2,38 3,93 141 58,3 2,42 3,98 159 67,7 2,35 4,05 183 75,3 2,43 3,87 201 87,4 2,30 3,88 225 95,3 2,36 3,93 261 108 2,41 4,13 294 123 2,38 3,93 125 42,8 2,92 140 47,5 2,95 158 52,2 3,03 178 59,5 2,99 205 68,6 2,99 226 76,1 2,97 253 83,8 3,02 295 96,1 3,07 330 110 3 112 43,5 37 128 50,3 43,3 146 56,3 48,9 165 65,4 57,3 190 73 62,7 208 84,4 73,3 234 92,3 80,6 271 105 92 305 119 104 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 82 50 82 50 82 50 82 50 83 51 83 51 83 51 85 53 86 54 3110 2220 1700 1460 3110 2220 2150 1700 3110 2220 2150 1900 3110 2220 2150 2050 4110 2220 2150 2310 4110 2220 2150 2370 4110 2220 2150 2520 5110 2220 2150 2800 5110 2220 2150 2940 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0504-1204 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 0152-0612 1100 1100 2000 H 600 600 1000 H A B A B 150 151 Hydronic - reversible NECS-N 0202T÷0612T Versions B LN base version low noise version Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) SHELL AND TUBES EXCHANGER The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets. INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head. MAXIMUM RELIABILITY Unit with dual-circuit refrigerant section designed to ensure maximum efficiency at full load, ensuring continuity without interruption of operation in the event of temporary stop of one of the 2 circuits. Reversible unit, air source for outdoor installation 50,3 - 169 kW Main accessories Unit Description Outdoor reversible heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, axial-flow fans, shell and tubes heat exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with two compressors on two independent refrigerant circuits. Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 152 UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊRubber anti-vibration mounting kit UÊLCD display keyboard type W3000Compact with multilanguage user interface (refers to the shown picture) SHELL & TUBES SCROLL AXIAL HEATING COOLING NECS-N / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T kW kW 50,3 18,4 2,73 3,52 57,5 20,4 2,82 3,59 72 28 2,57 3,31 82,5 32 2,58 3,3 93,9 36 2,61 3,31 107 39,8 2,68 3,39 120 44 2,73 3,45 138 50,4 2,73 3,46 151 58,9 2,56 3,26 kW kW 55,1 18,6 2,96 65,2 21,2 3,08 81 26,1 3,10 93,5 29,8 3,14 105 33,9 3,11 121 37,9 3,18 136 42,3 3,21 157 48,4 3,23 173 54,4 3,17 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 84 52 84 52 85 53 86 54 86 54 86 54 87 55 87 55 87 55 2195 1120 1420 * 2195 1120 1420 * 2195 1120 1420 * 2195 1120 1420 * 2745 1120 1420 * 2745 1120 1420 * 3245 1120 1620 * 3245 1120 1620 * 3245 1120 1620 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories NECS-N / LN Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T kW kW 48 19,1 2,52 3,52 54,6 21,4 2,56 3,31 73,2 27,2 2,69 3,46 83,5 31,9 2,62 3,33 93,9 36 2,61 3,33 103 41,6 2,48 3,17 119 44,6 2,67 3,38 132 53,3 2,47 3,16 143 62,7 2,28 2,93 kW kW 54,1 18,1 3,00 63,6 20,7 3,08 84,1 26,1 3,22 96,2 30,4 3,16 109 34,1 3,19 121 37,9 3,18 137 42,4 3,24 154 48,3 3,19 170 54,3 3,12 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 80 48 80 48 81 49 83 51 83 51 83 51 84 52 84 52 84 52 2195 1120 1420 * 2195 1120 1420 * 2745 1120 1420 * 2745 1120 1620 * 2745 1120 1620 * 2745 1120 1620 * 3245 1120 1620 * 3245 1120 1620 * 3245 1120 1620 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0202T-0612T Switchboard side Switchboard opposite side Condensation coil side mm mm mm 600 600 1000 H A B 153 Hydronic - reversible NECS-N 1314÷3218 Versions B SL CA base version super-low noise version Class A of efficiency Configurations D base function partial condensing heat recovery function Features Reversible unit, air source for outdoor installation 339 - 898 kW Unit Description Outdoor heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, ozone-friendly refrigerant R410A, axial-flow fans, shell and tubes exchanger and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration. Commands W3000SE Compact The W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 154 REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) SHELL AND TUBES EXCHANGER The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS-N represents the best choice for all the hydronic application on the residential, commercial and industrial markets. ELECTRONIC EXPANSION VALVE SUPPLIED STANDARD The use of the electronic expansion valve generates considerable benefits, especially in cases of variable demand and different external conditions. It was introduced into these units as a result of accurate design choices concerning the cooling circuit and the optimisation of operation in various different working conditions CLASS A EFFICIENCY The full range is also available with the Class A efficiency rating. NECS-N/CA guaranties premium levels of efficiency thanks to the generous sizing of the refrigerantexchange surface areas and to an accurate control of the fans. INTEGRATED HYDRONIC MODULE The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank Main accessories UÊSoft starters UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊRemote keyboard (distance to 200m and to 500m) UÊLT kit for extending the operating limits in heat pump mode down to -10°C (/SL versions) and -12°C (/CA versions) ENERGY CLASS SHELL & TUBES SCROLL AXIAL COOLING HEATING NECS-N / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 340 114 2,60 3,80 364 120 2,76 3,88 396 139 2,62 3,79 434 150 2,64 3,88 478 160 2,69 3,78 524 173 2,74 3,89 546 180 2,76 3,91 594 209 2,62 3,77 637 213 2,69 3,78 678 229 2,68 3,83 728 240 2,76 3,92 761 259 2,69 3,88 792 279 2,62 3,78 kW kW 371 110 3,03 398 118 3,07 436 131 3,05 474 142 3,04 515 153 3,02 572 169 3,06 597 176 3,08 654 196 3,05 686 203 3,02 742 221 3,03 796 235 3,08 834 248 3,07 871 262 3,05 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 dB(A) dB(A) 96 64 96 64 96 64 96 64 97 65 97 65 97 65 98 66 98 65 98 65 99 66 99 66 99 66 3905 2260 2450 3170 3905 2260 2450 3250 3905 2260 2450 3280 4515 2260 2450 4220 5690 2260 2450 4610 5690 2260 2450 4740 5690 2260 2450 4810 5690 2260 2450 4860 7430 2260 2450 5950 7430 2260 2450 6080 7430 2260 2450 6230 7430 2260 2450 6260 7430 2260 2450 6300 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories NECS-N / SL Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 320 131 2,44 3,99 343 138 2,49 4 383 154 2,48 3,97 413 170 2,42 4,05 444 185 2,40 3,99 493 199 2,47 4,07 516 207 2,49 4,06 574 232 2,48 3,95 593 247 2,40 4 638 262 2,43 4,05 688 276 2,49 4,06 726 293 2,48 4,06 765 309 2,48 3,96 kW kW 368 117 3,14 390 125 3,12 442 139 3,18 474 152 3,11 513 164 3,12 564 180 3,14 586 187 3,12 663 209 3,17 684 219 3,12 736 235 3,14 781 250 3,13 838 264 3,17 884 278 3,17 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 dB(A) dB(A) 88 56 88 56 88 56 89 57 89 57 90 57 90 57 91 58 91 58 91 58 92 59 92 59 92 59 4515 2260 2450 3400 5080 2260 2450 3530 5080 2260 2450 3680 5690 2260 2450 4720 5690 2260 2450 4860 6865 2260 2450 5160 7430 2260 2450 5270 7430 2260 2450 5500 7430 2260 2450 6280 8605 2260 2450 6580 9780 2260 2450 6830 9780 2260 2450 6990 9780 2260 2450 7140 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 155 NECS-N / CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 352 121 2,90 4,12 372 128 2,91 4,20 417 143 2,91 4,07 453 155 2,91 4,19 504 173 2,92 4,08 538 185 2,91 4,18 559 192 2,92 4,17 625 215 2,91 4,09 667 228 2,92 4,09 710 242 2,93 4,14 745 256 2,92 4,18 789 270 2,92 4,17 833 287 2,91 4,09 kW kW 383 119 3,21 409 128 3,20 449 140 3,21 497 155 3,21 533 166 3,21 586 183 3,21 614 191 3,21 674 210 3,21 708 221 3,20 766 239 3,20 819 255 3,21 860 269 3,20 898 280 3,21 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 dB(A) dB(A) 97 65 97 65 97 65 97 65 98 66 98 66 98 66 99 67 99 66 99 66 100 67 100 67 100 67 5080 2260 2450 3490 5080 2260 2450 3580 5080 2260 2450 3610 6255 2260 2450 4840 7430 2260 2450 5120 7430 2260 2450 5270 7430 2260 2450 5350 7430 2260 2450 5400 9780 2260 2450 6610 9780 2260 2450 6760 9780 2260 2450 6940 9780 2260 2450 6970 9780 2260 2450 7000 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1314-3218 Switchboard side Switchboard opposite side Plant exchagers opposite side Plant exchagers side mm mm mm mm 1500 1500 1500 2000 H B 156 A 157 Hydronic - reversible NECS-ST-N 0504÷1204 Versions B HL HT LN SL base version low noise, high efficiency, high outdoor temperature version high efficiency, high outdoor temperature version low noise version super-low noise version Configurations D base function partial condensing heat recovery function Features Reversible unit, air source for outdoor installation 103 - 322 kW Unit Description Outdoor reversible heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, axial-flow fans, shell and tubes exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with four compressors on two circuits. REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY Climaveneta is the only company offering units with Scroll compressors in 5 versions and 2 different configurations designed to satisfy all service system and application requirements SHELL AND TUBES EXCHANGER The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS-N represents the best choice for all the hydronic application on the residential, commercial and industrial markets. INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head. Main accessories Commands W3000SE Compact The W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 158 UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊLT kit for working down to -10°C in heat pump mode UÊRubber anti-vibration mounting kit. Spring anti-vibration mounting kit SHELL & TUBES AXIAL r HFC R-410A SCROLL HEATING COOLING NECS-ST-N / B Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 111 43,7 2,54 3,99 129 54 2,39 3,39 147 60 2,45 3,57 166 68,9 2,41 3,64 189 75,9 2,49 3,80 211 85,1 2,48 3,88 240 95,6 2,51 3,68 277 107 2,58 3,84 311 120 2,58 3,93 127 43,6 2,91 145 52,7 2,75 167 58 2,88 185 64,7 2,86 209 72,1 2,90 234 79,9 2,93 267 92,1 2,90 306 104 2,94 344 116 2,96 116 42,5 35,4 134 52,4 40,7 152 58,1 46 172 66,8 54 196 73,4 60,1 219 82,5 68,6 249 92,7 74,1 287 104 84,6 322 117 96,3 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 91 59 92 60 92 60 92 60 92 60 93 61 94 62 95 63 95 63 3110 2220 1700 1380 3110 2220 1700 1570 3110 2220 1700 1750 3110 2220 2150 1900 3110 2220 2150 2080 4110 2220 2150 2270 4110 2220 2150 2410 4110 2220 2150 2540 4110 2220 2150 2700 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories NECS-ST-N / HL Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 113 43,8 2,58 3,75 129 51 2,53 3,81 142 58,9 2,41 3,78 163 67,4 2,42 3,91 190 73,9 2,57 3,79 209 84,6 2,47 3,81 236 92,6 2,55 3,92 273 103 2,63 4,11 307 119 2,57 3,91 128 44,3 2,89 144 49,2 2,93 159 53,9 2,95 181 60,9 2,97 211 71 2,97 233 78,7 2,96 261 86,4 3,02 303 98,7 3,07 340 112 3,01 117 42,3 34,7 133 49,1 41 148 57,1 48,3 169 64,9 55,6 197 71,6 59,6 217 82,2 69,4 245 89,4 76 283 101 86,4 318 116 98,1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 86 54 86 54 86 54 86 54 88 56 88 56 88 56 90 58 91 59 3110 2220 1700 1460 3110 2220 2150 1700 3110 2220 2150 1840 3110 2220 2150 1980 4110 2220 2150 2310 4110 2220 2150 2370 4110 2220 2150 2520 5110 2220 2150 2800 5110 2220 2150 2940 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 159 NECS-ST-N / HT Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 117 45,5 2,57 3,42 134 51,3 2,61 3,53 149 58,4 2,55 3,64 172 65,7 2,62 3,77 198 75,3 2,63 3,57 219 84,9 2,58 3,60 248 91,5 2,71 3,82 287 102 2,79 3,98 322 118 2,71 3,80 134 48,2 2,78 150 53 2,83 167 58 2,88 191 65,2 2,93 220 76,9 2,86 244 84,7 2,88 274 92,3 2,97 315 104 3,02 357 121 2,95 121 44,1 33 139 49,8 38,3 155 56,8 44,8 178 63,7 51,1 205 73,1 56 228 82,7 64,8 257 88,9 70,6 297 99,6 80,5 334 115 91,2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 92 60 92 60 92 60 92 60 94 62 94 62 94 62 97 64 97 65 3110 2220 1700 1460 3110 2220 2150 1700 3110 2220 2150 1840 3110 2220 2150 1980 4110 2220 2150 2310 4110 2220 2150 2370 4110 2220 2150 2520 5110 2220 2150 2800 5110 2220 2150 2940 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories NECS-ST-N / LN Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 103 46,2 2,23 3,89 123 53,5 2,30 3,66 141 60 2,35 3,74 156 70,3 2,22 3,78 177 78,3 2,26 3,77 199 87,7 2,27 3,89 227 96,2 2,36 3,76 261 110 2,37 3,92 291 125 2,32 3,86 122 41,5 2,94 138 48,9 2,82 158 53,7 2,94 176 60,7 2,90 198 67,8 2,92 225 75,5 2,98 254 86,1 2,95 290 98 2,96 324 110 2,94 107 44,7 39,2 128 51,8 43,5 146 58 49,2 162 68,2 58,7 184 75,9 65,7 207 84,9 74,1 236 93,4 79,7 270 107 92 302 121 105 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 85 53 86 54 86 54 86 54 86 54 87 55 88 56 89 57 89 57 3110 2220 1700 1380 3110 2220 1700 1570 3110 2220 1700 1750 3110 2220 2150 1900 3110 2220 2150 2080 4110 2220 2150 2270 4110 2220 2150 2410 4110 2220 2150 2540 4110 2220 2150 2700 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 160 NECS-ST-N / SL Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0504 0524 0604 0704 0804 0904 1004 1104 1204 108 45 2,40 3,84 124 52,1 2,38 3,93 141 58,3 2,42 3,98 159 67,7 2,35 4,05 183 75,3 2,43 3,87 201 87,4 2,30 3,88 225 95,3 2,36 3,93 261 108 2,41 4,13 294 123 2,38 3,93 125 42,8 2,92 140 47,5 2,95 158 52,2 3,03 178 59,5 2,99 205 68,6 2,99 226 76,1 2,97 253 83,8 3,02 295 96,1 3,07 330 110 3 112 43,5 37 128 50,3 43,3 146 56,3 48,9 165 65,4 57,3 190 73 62,7 208 84,4 73,3 234 92,3 80,6 271 105 92 305 119 104 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 82 50 82 50 82 50 82 50 83 51 83 51 83 51 85 53 86 54 3110 2220 1700 1460 3110 2220 2150 1700 3110 2220 2150 1900 3110 2220 2150 2050 4110 2220 2150 2310 4110 2220 2150 2370 4110 2220 2150 2520 5110 2220 2150 2800 5110 2220 2150 2940 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0504-1204 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 H B A 161 Hydronic - reversible RECS 1052÷1952 Versions B LN LT SL base version low noise version low outdoor temperature version super-low noise version Features FLEXIBILITY Flexibility in applications thanks to the many available functions and versions EXTENSIVE RANGE OF OPERATION Extensive range of operation with external air temperature up to 46°C in summer and down to -10°C in winter with LT version HOT WATER SUPPLY Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions STANDARD WATER PUMP Standard water pump with pump unit options and possible storage tank: 1 or 2 pumps, 2 or 4-pole motor, for high or low head Main accessories Reversible unit, air source for outdoor installation 195 - 385 kW UÊCompressor power factor device UÊElectronic expansion valve UÊVariable speed condensation control (standard on /LN, /SL) UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board Unit Description Outdoor unit in heat pump mode for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, plate heat exchanger and thermostatic expansion valve. Frame with base in polyester-painted thick hot-galvanised sheet steel and external panels in peraluman. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 162 PLATES r HFC R-134a SCREW AXIAL COOLING HEATING RECS / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1052 1152 1352 1552 1752 1952 kW kW 195 73,9 2,64 3,43 238 95,6 2,49 3,13 276 109 2,53 3,25 307 113 2,70 3,49 359 138 2,59 3,31 385 154 2,49 3,34 kW kW 212 70 3,03 259 89,6 2,89 301 102 2,94 332 107 3,08 389 130 2,97 418 140 2,97 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 96 64 97 65 97 65 98 66 98 66 98 66 4610 2220 2150 2910 4610 2220 2150 3450 4610 2220 2420 3590 5610 2220 2430 3860 5610 2220 2430 4100 5610 2220 2430 4170 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories RECS / LN Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1052 1152 1352 1552 1752 1952 kW kW 189 74,7 2,53 3,61 229 96,2 2,38 3,26 266 112 2,37 3,37 298 115 2,59 3,68 346 141 2,45 3,46 371 158 2,34 3,48 kW kW 205 65,9 3,11 247 83,2 2,97 289 96 3,01 322 101 3,17 374 123 3,04 401 132 3,03 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 90 58 91 59 91 59 92 60 92 60 92 60 4610 2220 2150 2910 4610 2220 2150 3450 4610 2220 2420 3590 5610 2220 2430 3860 5610 2220 2430 4100 5610 2220 2430 4170 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 163 RECS / LT Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1052 1152 1352 1552 1752 1952 kW kW 200 74,7 2,69 3,19 248 88,6 2,80 3,38 289 103 2,78 3,25 313 113 2,77 3,36 372 133 2,79 3,32 399 147 2,70 3,34 kW kW 220 74,6 2,95 272 90,7 3,00 318 107 2,96 342 112 3,04 406 136 2,98 438 146 2,99 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 97 65 97 65 97 65 98 66 99 66 99 66 4610 2220 2150 3010 5610 2220 2430 3790 5610 2220 2430 3930 5610 2220 2430 3960 6610 2220 2430 4650 6610 2220 2430 4720 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories RECS / SL Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1052 1152 1352 1552 1752 1952 kW kW 190 74,5 2,55 3,59 228 95,4 2,39 3,38 266 110 2,40 3,50 298 115 2,57 3,69 333 148 2,24 3,38 378 152 2,48 3,63 kW kW 206 66,5 3,10 249 81,9 3,04 294 94,8 3,10 322 101 3,17 363 119 3,03 412 132 3,11 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 86 54 87 55 87 55 88 56 88 56 88 55 4610 2220 2150 3010 4610 2220 2420 3550 5610 2220 2430 3830 5610 2220 2430 3960 5610 2220 2430 4100 6610 2220 2430 4720 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1052-1952 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 H A B 164 165 Hydronic - reversible RECS 1062÷1962 Versions B LN LT SL base version low noise version low outdoor temperature version super-low noise version Configurations D base function partial condensing heat recovery function Features FLEXIBILITY Flexibility in applications thanks to the many available functions and versions EXTENSIVE RANGE OF OPERATION Extensive range of operation with external air temperature up to 46°C in summer and down to -10°C in winter with LT version HOT WATER SUPPLY Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions Reversible unit, air source for outdoor installation 195 - 385 kW Main accessories Unit Description Outdoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, external coil with copper tubes and aluminium fines, shell and tubes heat exchangers designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are galvanized epoxy powder coated steel with increased thickness. These units are designed for two-pipes systems and are able to produce hot or cold water according to the selected operation mode; the precise thermoregulation guarantees an optimal response to load´s changes, in every operating conditions. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 166 UÊRemote keyboard (distance to 200m and to 500m) UÊCompressor power factor device UÊElectronic expansion valve UÊVariable speed condensation control (standard on /LN, /SL) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board SHELL & TUBES r HFC R-134a SCREW AXIAL COOLING HEATING RECS / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1062 1162 1362 1562 1762 1962 kW kW 195 73,9 2,64 3,43 238 95,6 2,49 3,13 276 109 2,53 3,25 307 113 2,70 3,49 359 138 2,59 3,31 385 154 2,49 3,34 kW kW 212 70 3,03 259 89,6 2,89 301 102 2,94 332 107 3,08 389 130 2,97 418 140 2,97 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 96 64 97 65 97 65 98 66 98 66 98 66 4610 2220 2150 2960 4610 2220 2150 3470 4610 2220 2420 3860 5610 2220 2430 4140 5610 2220 2430 4340 5610 2220 2430 4640 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories RECS / LN Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1062 1162 1362 1562 1762 1962 kW kW 189 74,8 2,53 3,61 229 96,3 2,38 3,26 266 112 2,37 3,37 298 115 2,59 3,68 346 141 2,45 3,46 371 158 2,34 3,48 kW kW 205 65,9 3,11 247 83,4 2,97 289 96,1 3,01 322 102 3,17 374 123 3,04 401 132 3,03 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 90 58 91 59 91 59 92 60 92 60 92 60 4610 2220 2150 2960 4610 2220 2150 3470 4610 2220 2420 3860 5610 2220 2430 4140 5610 2220 2430 4340 5610 2220 2430 4640 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 167 RECS / LT Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1062 1162 1362 1562 1762 1962 kW kW 200 74,5 2,68 3,19 248 88,7 2,80 3,38 289 104 2,78 3,25 313 113 2,77 3,36 372 134 2,78 3,32 399 148 2,70 3,34 kW kW 220 74,6 2,95 272 90,5 3,01 318 108 2,94 342 112 3,05 406 136 2,99 438 147 2,98 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 97 65 97 65 97 65 98 66 99 66 99 66 4610 2220 2150 3060 5610 2220 2430 3840 5610 2220 2430 4230 5610 2220 2430 4240 6610 2220 2430 4910 6610 2220 2430 5210 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories RECS / SL Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 1062 1162 1362 1562 1762 1962 kW kW 190 74,4 2,55 3,59 228 95,2 2,39 3,38 266 111 2,40 3,50 298 116 2,57 3,69 333 149 2,23 3,38 378 152 2,49 3,63 kW kW 206 66,5 3,10 249 81,7 3,05 294 94,7 3,10 322 102 3,16 363 120 3,02 412 133 3,10 N. 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 86 54 87 55 87 55 88 56 88 56 88 55 4610 2220 2150 3060 4610 2220 2420 3570 5610 2220 2430 4130 5610 2220 2430 4240 5610 2220 2430 4340 6610 2220 2430 5210 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1062-1962 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 168 169 Hydronic - reversible FOCS-N 2022÷4822 Versions B CA LN-CA SL-CA base version Class A of efficiency Low Noise, Class A of efficiency Super Low noise version, Class A of efficiency Configurations D base function partial condensing heat recovery function Features HIGH EFFICIENCY Unit in Class A as per Eurovent. High efficiency for low energy consumption during the operating hours COMPACTNESS Reduced dimensions, for easy installation even in sites with space´ constraints EXTENSIVE RANGE OF OPERATION Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer. HOT WATER SUPPLY Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions Reversible unit, air source for outdoor installation 441 - 1162 kW Main accessories Unit Description Outdoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, external coil with copper tubes and aluminium fines, shell and tubes heat exchangers designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are galvanized epoxy powder coated steel with increased thickness. These units are designed for two-pipes systems and are able to produce hot or cold water according to the selected operation mode; the precise thermoregulation guarantees an optimal response to load´s changes, in every operating conditions. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 170 UÊHydronic group UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation UÊElectronic expansion valve UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards ENERGY CLASS SHELL & TUBES AXIAL SCREW r HFC R-134a HEATING COOLING FOCS-N / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 2022 2222 2422 2622 2722 3222 3622 4222 4822 kW kW 450 163 2,76 * 494 177 2,79 * 531 187 2,84 * 572 209 2,74 * 663 229 2,90 * 791 273 2,90 * 916 299 3,06 * 1028 343 3,00 * 1146 389 2,95 * kW kW 479 152 3,15 524 166 3,16 566 178 3,18 600 188 3,19 698 215 3,25 823 252 3,27 946 283 3,34 1072 322 3,33 1195 363 3,29 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 99 67 101 69 101 69 101 69 101 69 102 70 102 70 104 72 104 72 4900 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 7000 2260 2430 * 7900 2260 2430 * 10000 2260 2430 * 10000 2260 2430 * 11800 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories FOCS-N / CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 2022 2222 2422 2622 2722 3222 3622 4222 4822 kW kW 459 158 2,91 * 503 170 2,96 * 538 181 2,97 * 586 202 2,90 * 672 222 3,03 * 803 264 3,04 * 928 291 3,19 * 1041 343 3,03 * 1162 378 3,07 * kW kW 470 143 3,29 520 156 3,33 553 167 3,31 590 177 3,33 683 202 3,38 804 238 3,38 923 265 3,48 1051 309 3,40 1166 341 3,42 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 99 67 101 69 101 69 101 69 101 69 102 70 102 70 104 72 104 72 4900 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 7000 2260 2430 * 7900 2260 2430 * 10000 2260 2430 * 11800 2260 2430 * 11800 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories 171 FOCS-N / LN-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 2022 2222 2422 2622 2722 3222 3622 4222 4822 kW kW 444 160 2,78 * 492 169 2,91 * 524 182 2,88 * 564 205 2,75 * 654 224 2,92 * 780 267 2,92 * 904 290 3,12 * 1013 342 2,96 * 1130 380 2,97 * kW kW 467 143 3,27 520 156 3,33 553 167 3,31 586 177 3,31 683 202 3,38 804 238 3,38 923 265 3,48 1051 309 3,40 1166 341 3,42 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 93 61 95 63 95 63 95 63 95 63 96 64 96 64 98 66 98 66 4900 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 7000 2260 2430 * 7900 2260 2430 * 10000 2260 2430 * 10000 2260 2430 * 11800 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories FOCS-N / SL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 2022 2222 2422 2622 2722 3222 3622 4222 4822 kW kW 441 163 2,71 * 488 172 2,84 * 520 185 2,81 * 559 209 2,67 * 649 227 2,86 * 772 271 2,85 * 895 293 3,05 * 1004 346 2,90 * 1119 385 2,91 * kW kW 461 142 3,25 514 155 3,32 546 166 3,29 578 175 3,30 674 200 3,37 794 235 3,38 911 262 3,48 1039 305 3,41 1151 338 3,41 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 89 57 91 59 91 59 91 59 91 59 92 60 92 60 94 62 94 62 4900 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 5800 2260 2430 * 7000 2260 2430 * 7900 2260 2430 * 10000 2260 2430 * 11800 2260 2430 * 11800 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 2022-4822 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 172 173 Hydronic - reversible NECS-CN 0152÷1204 Versions B base version Configurations D base function partial condensing heat recovery function Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY The NECS-CN units are available with both vertical and horizontal air outflow. The horizontal outflow version is particularly effective in installations where the height of the technical compartment does not allow the traditional vertical outflow HIGH PERFORMANCE CENTRIFUGAL FANS The units are fitted with statically and dynamically balanced double-inlet centrifugal fans coupled by belt and pulleys. Useful static pressure up to 180 Pa. INTEGRATED HYDRONIC MODULE The built-in hydronic module includes the main water circuit components; it is available in various configurations with one or two pumps with high or low head. Reversible unit, air source for indoor installation 36,0 - 303 kW Main accessories Unit Description Indoor unit with heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, centrifugal fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil Pereluman) and base in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions. Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. 174 UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊHorizontal or vertical air outflow UÊRubber anti-vibration mounting kit PLATES CENTRIFUGAL r HFC R-410A SCROLL HEATING COOLING NECS-CN / B Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. FANS Fan air flow m3/h Max AESP (4) Pa NOISE LEVELS Sound power (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW EER ESEER HEATING ONLY Heating capacity (2) kW Total power input (2) kW COP COOLING WITH PARTIAL RECOVERY Cooling capacity (3) kW Total power input (3) kW Desuperheater heating capacity (3) kW COMPRESSORS No. Compressors/No. Circuits N. FANS Fan air flow m3/h Max AESP (4) Pa NOISE LEVELS Sound power (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0152 0182 0202 0252 0302 0352 0412 0452 0512 36,0 15,0 2,76 4,65 42,0 17,0 2,78 4,48 49,0 20,0 2,75 4,48 55,0 22,0 2,70 4,36 73,0 31,0 2,62 3,85 84,0 35,0 2,65 3,95 95,0 39,0 2,66 3,92 107 44,0 2,66 3,98 119 50,0 2,61 3,74 42,0 15,0 3,24 48,0 17,0 3,22 56,0 19,0 3,21 64,0 22,0 3,15 82,0 30,0 3,08 95,0 34,0 3,11 107 38,0 3,12 122 42,0 3,16 135 47,0 3,10 37,8 14,4 11,9 43,9 16,6 13,3 50,9 19,1 15,7 57,4 21,7 17,9 75,7 30,3 23,2 87,3 34,0 26,4 98,5 37,9 29,8 111 42,5 33,6 124 48,0 37,4 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 15012 120 16992 120 16992 120 16992 120 29988 120 29988 120 29988 120 32004 120 34992 120 81 83 83 83 90 90 90 92 94 2200 920 1642 720 2200 920 1642 730 2200 920 1642 750 2200 920 1642 790 2602 1104 1927 1080 2602 1104 1927 1170 2602 1104 1927 1230 3602 1104 1927 1470 3602 1104 1927 1490 0552 0612 0604 0704 0804 0904 1004 1104 1204 137 58,0 2,60 3,81 154 64,0 2,61 3,76 146 60,0 2,64 3,90 164 72,0 2,47 3,71 187 79,0 2,59 3,88 213 87,0 2,64 4,00 237 100 2,57 3,62 274 113 2,64 3,70 303 131 2,50 3,60 153 55,0 3,06 173 62,0 3,06 165 58,0 3,12 185 66,0 3,03 208 74,0 3,06 235 83,0 3,09 261 94,0 3,01 302 108 3,06 336 122 2,97 142 56,2 43,1 160 62,5 48,7 152 58,5 46,4 170 69,5 55,1 194 76,6 60,9 221 84,5 67,8 246 96,9 75,6 284 109 85,9 315 127 99,7 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 47988 120 47988 120 45000 120 47988 120 60012 120 60012 120 68004 120 79992 120 84996 120 94 94 92 94 94 94 96 96 97 3602 1104 1927 1600 3602 1104 1927 1660 3602 1277 1900 1980 3602 1277 1900 2055 4602 1277 2235 2475 4602 1277 2235 2630 4602 1277 2235 2725 5602 1277 2235 3145 5602 1277 2235 3205 Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C. 4 Useful pressure to be specified at the time of placing the order. 5 Total sound power of the fans as declared by the manufacturer referred to nominal speed of rotation and useful static head of 120 Pa on delivery side. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-1204 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1000 1000 2000 H A B 175 Hydronic - reversible NECS-WN 0152÷1204 Versions B base version Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) TOTAL VERSATILITY Climaveneta has designed the NECS-W units with a range of integral accessories in mind for operation with total water loss (well, water bed, etc.), dry cooler or cooling tower so as to satisfy all service system and installation requirements. INTEGRATED HYDRONIC MODULE ON COOLER/ CONDENSER SIDE The built-in hydronic module includes the main water circuit components; it is available in various configurations with one or two pumps with high or low head both on the evaporator and the condenser side. INTEGRATED CONDENSATION´S CONTROL The electronics of the units manages the most suitable condensing control for each type of application: pressurecontrolled valve, two or three-way modulating valve and inverter control for the pumps Reversible unit, water source Main accessories 43,4 - 371 kW Unit Description Water-cooled indoor unit for the production of chilled/hot water with hermetic rotary Scroll compressors, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil-Peraluman) and structure in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit fourcompressor versions. Commands W3000 Base / W3000SE Compact The controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. 176 UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊCondensing control device: two or three-way modulating pressure-controlled valve and inverter on pumps UÊWater connections directed upwards (for 2 compressors units only) UÊAcoustical enclosure to reduce the noise emissions. UÊRubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only) r HFC R-410A SCROLL PLATES COOLING HEATING NECS-WN / B Models COOLING ONLY Cooling capacity (1) Total power input (1) Condernser heating capacity (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0152 0182 0202 0252 0262 0302 0352 0412 0452 0512 kW kW 43,4 10,0 52,8 4,34 5,80 50,1 11,3 60,7 4,43 6,00 58,9 13,0 71,2 4,53 6,00 66,4 15,2 80,7 4,37 5,70 72,6 16,6 88,2 4,37 5,60 86,7 19,5 105 4,45 5,70 101 22,7 123 4,46 5,80 115 25,9 139 4,43 5,70 129 28,9 156 4,45 5,80 144 32,2 174 4,46 5,80 kW kW 50,5 12,9 3,91 58,2 14,3 4,07 68,0 16,7 4,07 77,0 19,2 4,01 85,0 21,1 4,03 101 24,7 4,09 117 28,7 4,07 132 32,2 4,10 148 36,0 4,12 165 40,0 4,14 N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 dB(A) dB(A) 73 74 74 74 75 76 77 77 78 78 1055 649 1255 290 1055 649 1255 305 1055 649 1255 315 1055 649 1255 325 1055 649 1255 330 1222 843 1496 585 1222 843 1496 605 1222 843 1496 660 1222 843 1496 685 1222 843 1496 740 mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) Condernser heating capacity (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP (2) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0552 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 165 36,9 200 4,47 5,90 186 41,6 225 4,48 5,80 174 38,9 211 4,47 5,80 203 45,2 245 4,48 5,90 228 51,6 276 4,42 5,80 258 58,0 312 4,45 5,90 288 64,0 348 4,50 5,90 329 74,0 398 4,44 6,00 371 83,5 450 4,44 5,90 kW kW 190 45,9 4,14 215 51,8 4,14 202 49,2 4,11 234 56,6 4,13 263 64,1 4,10 297 72,1 4,12 332 79,5 4,17 379 91,9 4,13 428 104 4,12 N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 79 79 86 87 88 89 90 91 91 1222 873 1496 790 1222 873 1496 830 2227 877 1780 1090 2227 877 1780 1165 2227 877 1780 1245 2227 877 1780 1290 2227 877 1780 1395 2227 877 1780 1500 2227 877 1780 1585 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C. 3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 4 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-0612 Switchboard side Switchboard opposite side Unit's side mm mm mm 0604-1204 800 600 600 H 1000 1000 1000 H B A B A 177 Hydronic - reversible RECS-W 0802÷3202 Versions B base version Configurations D base function partial condensing heat recovery function Features SILENT OPERATION If compared to the solution of a water condensed unit reversible on the hydronic side, these units allows a reduction in the required technical space and, moreover, an appreciable simplification in the plant´s design. INTEGRATED CONDENSATION´S CONTROL A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request. ADAPTABILITY Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic SILENT OPERATION Extremely silent operation thanks to the accurate units design. Optional integral acoustic enclosure, reduces more the sound level beyond the best on market Reversible unit, water source 174 - 801 kW Main accessories Unit Description Indoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, thermostatic expansion valve, shell and tube condenser and evaporator. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components. Commands W3000SE Large The W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, stepwise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. 178 UÊIntegral acoustical enclosure (type base or plus) UÊElectronic expansion valve UÊRemote keyboard UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board. SCREW SHELL & TUBES r HFC R-134a COOLING HEATING RECS-W / B Models COOLING ONLY Cooling capacity (1) kW Total power input (1) kW Condernser heating capacity (1) EER ESEER COOLING WITH PARTIAL RECOVERY (only -D) Cooling capacity (2) kW Total power input (2) kW Desuperheater heating capacity (2) kW HEATING ONLY Heating capacity (3) kW Total power input (3) kW COP (3) COMPRESSORS No. Compressors/No. Circuits N. NOISE LEVELS Sound power (4) dB(A) Sound pressure (5) dB(A) SIZE A (6) mm B (6) mm H (6) mm Operating weight (6) kg 0802 1002 1102 1302 1502 1702 1902 2152 2502 2602 2702 3202 174 39,3 211 4,43 5,31 213 49,2 259 4,33 5,43 246 55,8 298 4,41 5,13 292 65,6 354 4,46 5,40 334 75,2 404 4,44 5,57 379 88,5 462 4,28 5,31 429 98,9 522 4,34 5,51 499 109 602 4,57 5,75 583 128 703 4,57 5,58 631 137 760 4,61 5,50 703 154 848 4,56 5,54 800 176 966 4,55 5,67 181 38 17 221 47 21 255 54 24 303 63 28 346 73 32 393 85 38 445 95 43 518 105 47 605 123 55 655 132 59 729 149 67 831 170 76 199 47,1 4,23 245 58,7 4,17 283 67,9 4,16 334 78,6 4,25 381 89,5 4,26 436 107 4,09 496 120 4,13 571 132 4,32 665 153 4,35 715 162 4,40 806 185 4,35 912 211 4,32 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 94 * 95 * 97 * 97 * 97 * 97 * 97 * 98 * 99 * 99 * 99 * 99 * 3680 1170 1890 1990 3680 1170 1890 2070 3680 1170 1890 2490 3680 1170 1890 2940 3680 1170 1890 3020 3680 1170 1890 3060 3800 1240 1950 4080 3800 1240 1950 4460 3800 1240 1950 4840 4800 1240 2050 5390 4800 1240 2050 5490 4800 1240 2050 6340 Note: 1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard 2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C. 3 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C. 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0802-1702 Switchboard side Switchboard opposite side Condensation coil side Cooler water connections side (minimum) Condenser water connections side Condenser water fittings opposite side (minimum) 1902-3202 mm mm mm 800 0 0 1500 0 0 mm 500 900 mm 500 900 mm 500 900 H A B 179 Hydronic - reversible NECS-NR 0152÷1204 Versions B LN SL base version low noise version super-low noise version Features Reversible unit, NRG line, total heat recovery, air source for outdoor installation 36 - 311 kW Unit Description Air-cooled reversible unit with total heat recovery for the simultaneous production of chilled/ hot water with hermetic rotary Scroll compressors, with R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in Peraluman and base in galvanised sheet steel with paint finish. The range includes the two-compressor and the fourcompressor versions, both with two circuits. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 180 TOTAL VERSATILITY Unique proposal: unit designed to satisfy, according to the mode of operation, requirements of cold water, hot water for heating or hot water for domestic use EXTENSIVE RANGE OF OPERATION Extensive range of operation with external air temperature up to 46°C in summer and down to -10°C in winter with LT version HOT WATER SUPPLY Production of domestic hot water up to 52°C in both summer and winter operating conditions, offering maximum versatility with respect to different plant engineering solutions INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, available for both plant and recovery circuits (up to 4 pumps). Main accessories UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊRubber anti-vibration mounting kit PLATES SCROLL AXIAL r HFC R-410A NECS-NR / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 0152 0182 0202 0252 0262 0302 0412 0512 kW kW 36,6 13,3 2,76 43,2 14,5 2,99 48,5 17,9 2,71 55,8 19,9 2,80 61,2 22,8 2,68 73,3 26,2 2,80 94,8 33,6 2,82 120 41,7 2,88 kW kW 41,1 13,3 3,10 48,9 14,7 3,33 55,3 17,2 3,22 62,5 19,7 3,17 68,1 21,4 3,18 83,1 24,9 3,34 107 32,1 3,34 136 40 3,40 kW kW kW 37,2 12,8 49,2 43,6 14,2 56,9 50,6 16,6 66,2 57,2 18,9 75 64,1 21 83,8 76,3 24,5 99,3 97,7 31,9 128 124 39,6 161 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 84 52 84 52 84 52 84 52 84 52 85 53 86 54 87 55 2020 1300 1620 570 2020 1300 1620 590 2020 1300 1620 600 2520 1300 1620 660 2520 1300 1620 670 2520 1300 1620 720 3070 1300 1620 1030 3570 1300 1620 1180 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 151 56,6 2,66 150 58,9 2,54 166 69 2,41 189 75,8 2,49 211 85,2 2,48 240 95,6 2,51 277 107 2,58 311 121 2,58 kW kW 173 52,1 3,31 167 58 2,88 185 64,9 2,86 209 72,1 2,90 234 79,8 2,93 267 92 2,90 306 104 2,94 344 116 2,96 kW kW kW 160 51,3 208 151 198 49,8 173 226 57,1 194 255 64,5 220 288 72,1 246 321 79,8 281 368 92,8 317 415 105 N. 2/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 87 55 93 60 92 60 92 60 93 61 94 62 95 63 95 63 3570 1300 1620 1290 3110 2220 2150 1600 3110 2220 2150 1840 3110 2220 2150 2120 4110 2220 2150 2320 4110 2220 2150 2480 4110 2220 2150 2680 4110 2220 2150 2860 mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 181 NECS-NR / LN Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 0604 0704 0804 0904 1004 1104 1204 kW kW 143 58,8 2,43 157 70,2 2,24 177 78,4 2,26 199 87,8 2,27 227 96,5 2,36 261 110 2,37 291 125 2,32 kW kW 160 54 2,95 176 60,8 2,89 198 67,9 2,92 225 75,7 2,98 254 85,8 2,95 290 97,9 2,96 324 110 2,94 kW kW kW 151 198 49,8 173 226 57,1 194 255 64,5 220 288 72,1 246 321 79,8 281 368 92,8 317 415 105 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 86 54 86 54 86 54 87 55 88 56 89 57 89 57 3110 2220 2150 1600 3110 2220 2150 1840 3110 2220 2150 2120 4110 2220 2150 2320 4110 2220 2150 2480 4110 2220 2150 2680 4110 2220 2150 2860 mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 182 NECS-NR / SL Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 0152 0182 0202 0252 0262 0302 0412 0512 kW kW 33,3 15 2,21 39,6 16,5 2,39 47 18,7 2,52 50,9 22,4 2,28 58,3 24,4 2,39 69,1 28,4 2,43 93,9 34,1 2,75 119 42,3 2,81 kW kW 40 13,1 3,04 47,4 14,6 3,24 55,1 17,2 3,21 60,9 19,7 3,10 70,5 21,5 3,28 80,9 24,8 3,26 109 32,2 3,38 138 40,1 3,43 kW kW kW 37,2 12,8 49,2 43,6 0 56,9 50,6 16,6 66,2 57,2 18,9 74,9 64,1 21 83,8 76,3 24,5 99,3 97,7 31,9 128 124 39,6 161 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 78 46 78 46 79 47 79 47 79 47 80 48 82 50 83 51 2020 1300 1620 570 2020 1300 1620 590 2520 1300 1620 660 2520 1300 1620 660 2520 1300 1620 700 3070 1300 1620 780 3070 1300 1620 1070 3570 1300 1620 1230 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 143 60,4 2,37 142 58 2,45 160 67,4 2,37 183 75,5 2,43 201 87,3 2,30 225 95,5 2,36 261 108 2,41 294 123 2,38 kW kW 169 52 3,26 159 52,6 3,02 178 59,5 2,99 205 68,7 2,99 226 76,1 2,98 253 83,8 3,02 295 96,1 3,07 330 110 3 kW kW kW 160 51,3 208 151 198 49,8 173 226 57,1 194 255 64,5 220 288 72,1 246 321 79,8 281 368 92,8 317 415 105 N. 2/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 83 51 82 50 82 50 83 51 83 51 83 51 85 53 86 54 3570 1300 1620 1290 3110 2220 2150 1700 3110 2220 2150 1960 4110 2220 2150 2350 4110 2220 2150 2420 4110 2220 2150 2590 5110 2220 2150 2950 5110 2220 2150 3100 mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-1204 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 H H A B A B 183 Hydronic - reversible NECS-NR 1314÷3218 Versions B CA SL-CA base version Class A of efficiency Super Low noise version, Class A of efficiency Features Reversible unit, NRG line, total heat recovery, air source for outdoor installation 353 - 823 kW REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) HOT WATER SUPPLY Production of domestic hot water up to 55°C in both summer and winter operating conditions, offering maximum versatility with respect to different plant engineering solutions. CLASS A EFFICIENCY The full range is also available with the Class A efficiency rating. NECS-NR/CA and NECS-NR/SL-CA guaranty premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans, available on both standard and low-noise versions. INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, available for both plant and recovery circuits (up to 4 pumps). Unit Description Main accessories Air-cooled reversible unit with total heat recovery for the simultaneous production of chilled/ hot water with hermetic rotary Scroll compressors, with R410A, axial fans, shell and tube heat exchangers and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration. UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊLT kit for extending the operating limits in heat pump mode down to -10°C (/SL-CA versions) and -12°C (/CA versions) Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 184 ENERGY CLASS SHELL & TUBES SCROLL AXIAL NECS-NR / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 353 125 2,81 * 378 131 2,89 * 412 150 2,75 * 452 163 2,77 * 494 176 2,82 * 546 189 2,89 * 567 196 2,89 * 617 225 2,74 * 662 235 2,82 * 704 250 2,81 * 757 262 2,89 * 791 281 2,82 * 823 300 2,74 * kW kW 380 121 3,13 408 129 3,18 447 142 3,16 485 156 3,11 528 169 3,12 587 186 3,16 612 192 3,18 670 212 3,16 704 225 3,12 761 243 3,13 817 256 3,18 855 270 3,17 893 283 3,16 kW kW kW 355 107 455 379 113 485 423 126 542 460 139 590 500 150 640 547 163 700 569 170 728 636 189 814 667 200 854 711 213 912 758 227 971 802 1027 240 848 252 1085 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 96 64 96 64 96 64 96 64 97 65 97 65 97 65 98 66 98 65 98 65 99 66 99 66 99 66 3905 2260 2450 3530 3905 2260 2450 3620 3905 2260 2450 3650 4515 2260 2450 4850 5690 2260 2450 5240 5690 2260 2450 5370 5690 2260 2450 5430 5690 2260 2450 5480 7430 2260 2450 6700 7430 2260 2450 6830 7430 2260 2450 7000 7430 2260 2450 7030 7430 2260 2450 7060 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories NECS-NR / CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 362 122 2,96 * 387 128 3,03 * 425 145 2,94 * 471 157 3,01 * 524 173 3,04 * 559 185 3,03 * 581 192 3,03 * 637 217 2,94 * 680 230 2,95 * 724 244 2,96 * 775 256 3,03 * 813 272 2,99 * 850 289 2,94 * kW kW 394 120 3,30 420 127 3,31 462 140 3,30 507 155 3,28 546 166 3,29 603 183 3,30 630 190 3,32 693 210 3,30 729 221 3,29 788 2394 3,29 840 253 3,32 882 266 3,31 924 280 3,30 kW kW kW 355 107 394 379 113 485 423 126 542 460 139 590 500 150 640 547 163 700 569 170 728 636 189 814 667 200 854 711 213 912 758 227 971 802 240 1027 848 252 1085 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 97 65 97 65 97 65 97 64 98 65 98 65 98 65 99 66 99 66 99 66 100 67 100 67 100 67 5080 2260 2450 3850 5080 2260 2450 3950 5080 2260 2450 3980 6255 2260 2450 5460 7430 2260 2450 5740 7430 2260 2450 5890 7430 2260 2450 5970 7430 2260 2450 6020 9780 2260 2450 7350 9780 2260 2450 7500 9780 2260 2450 7700 9780 2260 2450 7740 9780 2260 2450 7770 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 185 NECS-NR / SL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 332 130 2,56 * 357 137 2,61 * 398 153 2,60 * 429 169 2,54 * 500 640 2,52 * 512 198 2,59 * 536 205 2,61 * 596 230 2,60 * 616 244 2,52 * 663 260 2,55 * 715 274 2,61 * 754 290 2,60 * 795 306 2,60 * kW kW 378 116 3,25 400 124 3,22 453 138 3,29 486 151 3,22 526 163 3,23 578 178 3,25 601 186 3,23 679 207 3,28 701 217 3,23 755 233 3,24 801 248 3,23 859 262 3,28 906 276 3,28 kW kW kW 355 107 455 379 113 485 423 126 542 460 139 590 500 150 640 547 163 700 569 170 728 636 189 814 667 200 854 711 213 912 758 227 971 802 1027 240 848 252 1085 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 88 56 88 56 88 56 89 57 89 57 90 57 90 57 91 58 91 58 91 58 92 59 92 59 92 59 4515 2260 2450 3760 5080 2260 2450 3900 5080 2260 2450 4050 5690 2260 2450 5350 5690 2260 2450 5490 6865 2260 2450 5780 7430 2260 2450 5890 7430 2260 2450 6130 7430 2260 2450 7020 8605 2260 2450 7330 9780 2260 2450 7600 9780 2260 2450 7750 9780 2260 2450 7910 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1314-3218 Switchboard side Switchboard opposite side Plant exchagers opposite side Plant exchagers side mm mm mm mm 1500 1500 1500 2000 H B 186 A 187 Hydronic - reversible FOCS-NR 1062÷3222 Versions CA LN-CA SL-CA XL-CA XL-CA-E Class A of efficiency Low Noise, Class A of efficiency Super Low noise version, Class A of efficiency eXtra Low noise version, Class A of efficiency eXtra Low noise, Class A enhanced Features Reversible unit, NRG line, total heat recovery, air source for outdoor installation 200 - 826 kW Unit Description Outdoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, external coil with copper tubes and aluminium fines, shell and tubes heat exchangers designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are galvanized epoxy powder coated steel with increased thickness. These units are designed for two-pipes systems and are able to produce hot or cold water and even hot water on an auxiliary circuit when needed for domestic utilities or post heating for air conditioning units. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 188 UNIQUE PROPOSAL Unique proposal: unit designed to satisfy, according to the mode of operation, requirements of cold water, hot water for heating or hot water for domestic use EXTENSIVE RANGE OF OPERATION Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer. HOT WATER SUPPLY Hot water supply up to 55°C. In winter mode the unit manages hot water production in the plant-side heat exchanger and in the reclaim one, with priority setted by customer, eventually at two different set-points VERSION ´XL-CA-E´ AVAILABLE Exclusive Premium version. Together for the first time, the lowest noise level on the market and the maximum efficiency in each operating mode. Main accessories UÊCompressor power factor device UÊHydronic group UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards SHELL & TUBES r HFC R-134a SCREW AXIAL FOCS-NR / CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Total power input Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 kW kW 210 72,1 2,91 * 248 84,5 2,93 * 302 102 2,96 * 329 109 3,02 * 380 129 2,95 * 425 144 2,95 * 483 156 3,10 * 525 167 3,14 * 554 176 3,15 * 624 201 3,10 * 701 222 3,16 * 826 264 3,13 * kW kW 218 67 3,25 258 80,7 3,20 309 92,2 3,35 339 101 3,36 396 122 3,25 434 131 3,31 492 149 3,30 541 159 3,40 571 169 3,38 615 178 3,46 711 207 3,43 826 240 3,44 kW kW kW 209 60,6 269 248 71,9 320 305 87,1 392 329 92,5 422 381 111 493 428 122 549 484 137 621 521 145 666 551 153 704 631 170 801 702 193 895 832 224 1056 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 97 65 97 65 97 65 98 66 99 67 99 67 99 67 101 69 101 69 101 69 101 69 102 70 4610 2220 2150 * 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * kW dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories FOCS-NR / LN-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 kW kW 205 70,8 2,90 * 241 84,3 2,86 * 294 103 2,85 * 322 109 2,95 * 369 130 2,84 * 414 144 2,88 * 469 163 2,88 * 513 168 3,05 * 541 177 3,06 * 604 206 2,93 * 686 226 3,04 * 800 274 2,92 * kW kW 218 67 3,25 258 80,7 3,20 309 92,2 3,35 339 101 3,36 396 122 3,25 434 131 3,31 492 149 3,30 541 159 3,40 571 169 3,38 615 178 3,46 711 207 3,43 826 240 3,44 kW kW kW 209 60,6 269 248 71,9 320 305 87,1 392 329 92,5 422 381 111 493 428 122 549 484 137 621 521 145 666 551 153 704 631 170 801 702 193 895 832 224 1056 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 90 58 91 59 91 59 92 60 92 60 92 60 93 61 95 63 95 63 95 63 95 63 96 64 4610 2220 2150 * 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 189 FOCS-NR / SL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 kW kW 200 72,7 2,75 * 233 87,2 2,67 * 283 109 2,60 * 314 113 2,78 * 356 137 2,60 * 401 149 2,69 * 464 166 2,80 * 509 170 2,99 * 537 180 2,98 * 597 210 2,84 * 680 229 2,97 * 790 281 2,81 * kW kW 211 64,8 3,26 251 78,4 3,20 301 89,9 3,35 330 98,4 3,35 385 119 3,24 422 127 3,32 486 147 3,31 536 157 3,41 564 167 3,38 607 176 3,45 703 205 3,43 816 238 3,43 kW kW kW 209 60,6 269 248 71,9 320 305 87,1 392 329 92,5 422 381 111 493 428 122 549 484 137 621 521 145 666 551 153 704 631 170 801 702 193 895 832 224 1056 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 86 54 87 55 87 55 88 56 88 56 88 56 89 57 91 59 91 59 91 59 91 59 92 60 4610 2220 2150 * 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories FOCS-NR / XL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 2022 2222 2422 2622 2722 3222 kW kW 455 167 2,72 * 501 169 2,96 * 528 180 2,93 * 584 212 2,75 * 667 230 2,90 * 772 287 2,69 * kW kW 486 143 3,40 536 152 3,53 564 161 3,50 607 170 3,57 703 198 3,55 816 230 3,55 kW kW kW 484 137 621 521 145 666 551 153 704 631 170 801 702 193 895 832 224 1056 N. 2/2 2/2 2/2 2/2 2/2 2/2 85 53 87 55 87 55 87 55 87 55 88 56 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories 190 FOCS-NR / XL-CA-E Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 1062 1162 1362 1562 1762 2022 2222 2422 2622 kW kW 204 66,6 3,06 * 247 76,6 3,22 * 293 99,4 2,95 * 319 105 3,04 * 366 127 2,88 * 473 153 3,09 * 510 163 3,13 * 541 169 3,20 * 611 193 3,17 * kW kW 218 62,4 3,49 267 77,6 3,44 308 88,3 3,49 340 95,2 3,57 393 116 3,39 513 145 3,54 552 154 3,58 588 164 3,59 644 176 3,66 kW kW kW 209 60,6 269 248 71,9 320 305 87,1 392 329 92,5 422 381 111 493 484 137 621 521 145 666 551 153 704 631 170 801 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 85 53 86 54 86 54 87 55 87 55 86 54 88 56 88 56 88 56 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 8400 2260 2350 * 9300 2260 2350 * 9300 2260 2350 * 9300 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 1062-1762 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 2022-2622 1800 1500 2000 191 Hydronic - reversible NECS-WNR 0152÷1604 Versions - base version Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) INTEGRATED CONDENSATION´S CONTROL A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request. ENERGY SAVING Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be HOT WATER SUPPLY Production of domestic hot water up to 55°C in both summer and winter operating conditions, offering maximum versatility with respect to different plant engineering solutions. Reversible unit, NRG line, total heat recovery, water source 5,7 - 491 kW Unit Description Water source reversible unit with total heat recovery for the simultaneous production of chilled/ hot water with hermetic rotary Scroll compressors, with R410A, plate heat exchangers and thermostatic expansion valve. The range is composed by units equipped with two and four compressors, all with two refrigerant circuits. Commands W3000 large The controller W3000 large offers the latest control and functions developed directly by Climaveneta on the basis of their experience gained over the years with these particular units and the related plant engineering. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 192 Main accessories UÊRemote keyboard (distance to 200m and to 500m) UÊWater connections directed upwards (for 2 compressors units only) UÊAcoustical enclosure to reduce the noise emissions. UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board r HFC R-410A SCROLL PLATES NECS-WNR / Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Total power input Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 0152 0182 0202 0252 0262 0302 0412 0512 0612 kW kW 48,6 8,70 5,59 * 55,8 9,80 5,69 * 65 11,3 5,75 * 73,8 13,2 5,59 * 83,2 14,7 5,66 * 97,5 17,4 5,60 * 127 22,7 5,59 * 159 28,1 5,64 * 206 36,5 5,63 * kW kW 52,1 12,4 4,20 59,7 13,8 4,33 69,3 16,2 4,28 79 18,5 4,28 88,9 20,4 4,36 104 23,9 4,37 135 31 435 169 38,4 4,40 219 49,9 4,38 kW kW kW 40,4 12,4 52,1 46,7 13,8 59,7 54,1 16,2 69,3 61,7 18,5 79 67,9 20,4 88,9 82 23,9 104 106 31 135 133 38,4 169 172 49,9 219 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 73 42 74 43 74 43 74 43 75 44 76 45 77 46 78 47 79 48 1222 893 1496 450 1222 893 1496 470 1222 893 1496 490 1222 893 1496 505 1222 893 1496 525 1222 893 1496 550 1222 893 1496 745 1222 893 1496 825 1222 893 1496 910 0604 0704 0804 0904 1004 1104 1204 1404 1604 kW kW 194 34,8 5,58 * 225 40 5,63 * 255 45,3 5,62 * 285 50,8 5,61 * 317 56,3 5,63 * 365 64,8 5,63 * 413 73 5,66 * 468 84,1 5,56 * 522 95,1 5,49 * kW kW 208 47,7 4,36 240 54,7 4,38 270 61,8 4,37 303 69,2 4,38 338 76,8 4,40 388 88,4 4,39 440 99,6 4,41 498 113 4,41 557 126 4,42 kW kW kW 163 47,7 208 188 54,7 240 212 61,8 270 238 69,2 303 266 76,8 338 305 88,4 388 346 99,6 440 392 113 498 438 126 557 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 86 54 87 55 88 56 89 57 90 58 91 59 91 59 91 59 91 59 2520 880 1810 975 2520 880 1810 1165 2520 880 1810 1365 2520 880 1810 1445 2520 880 1810 1610 2520 880 1810 1710 2520 880 1810 1810 2520 880 1810 1895 2520 880 1810 2000 kW dB(A) dB(A) mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Total power input Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) kW dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C 2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-0612 Switchboard side Switchboard opposite side Unit’s side mm mm mm 0604-1604 800 800 800 H 1000 1000 800 H B A B A 193 Hydronic - reversible FOCS-WNR 0802÷3202 Versions - base version Features UNIQUE PROPOSAL Unique proposal: unit designed to satisfy, according to the mode of operation, requirements of cold water, hot water for heating or hot water for domestic use ENERGY SAVING Free domestic hot water during summer season. HOT WATER SUPPLY Hot water supply up to 55°C. In winter mode the unit manages hot water production in the plant-side heat exchanger and in the reclaim one, with priority setted by customer, eventually at two different set-points INTEGRATED CONDENSATION´S CONTROL A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request. Main accessories Reversible unit, NRG line, total heat recovery, water source 194 - 891 kW Unit Description Heat pump unit for indoor installation, designed for 2-pipes plants application for summer/ winter air conditioning. Unit complete with a section for the condensation heat reclaim: a dedicated heat exchanger produces on request hot water for secondary uses (domestic hot water, air treatment in AHU, ...). Semi-hermetic screw compressor, R134a, shell and tube heat exchangers both, plant-side (primary, working as an evaporator or condenser as a function of unit´s commutation, and secondary, working only as a condenser) and source-side. Frame in polyester-painted galvanized steel. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 194 UÊIntegral acoustical enclosure (type base or plus) UÊSeveral devices for condensation´s control UÊElectronic expansion valve UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards r HFC R-134a SCREW SHELL & TUBES FOCS-WNR / Models COOLING ONLY Cooling capacity (1) Total power input (1) EER ESEER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Total power input (3) Heat recovery capacity (3) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Total power input Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 0802 1002 1102 1302 1502 1702 1902 2152 2502 2602 2702 3202 0802 kW kW 194 34,3 5,66 * 240 43,2 5,56 * 275 48,5 5,66 * 326 57,2 5,69 * 373 66,1 5,64 * 435 76,5 5,68 * 479 85,7 5,58 * 554 94,5 5,87 * 648 111 5,83 * 703 121 5,83 * 781 135 5,80 * 891 153 5,81 * 194 34,3 5,66 * kW kW 205 45,7 4,49 255 57,0 4,47 291 65,9 4,42 344 76,3 4,51 393 86,9 4,52 459 103 4,44 514 117 4,40 589 128 4,59 686 149 4,62 738 158 4,68 831 180 4,62 941 205 4,59 205 45,7 4,49 kW kW kW 162 45,7 205 201 57,0 255 229 65,9 291 272 76,3 344 311 86,9 393 362 103 459 404 117 514 468 128 589 547 149 686 589 158 738 662 180 831 748 205 941 162 45,7 205 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 94 76 95 77 97 79 97 79 97 79 97 79 97 78 98 79 99 80 99 80 99 80 99 80 94 76 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3800 1490 1950 * 3800 1490 1950 * 3800 1490 1950 * 5000 1490 1950 * 5000 1490 1950 * 5000 1490 1950 * 3680 1170 1950 * kW dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C 2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 5 Average sound pressure level, at 1 m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0802-3202 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 800 500 500 195 196 197 INTEGRA NECS-Q 0152÷1204 Versions B LN SL base version low noise version super-low noise version Features INTEGRA unit for 4-pipe systems, air source for outdoor installation 36 - 311 kW Unit Description Multi-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. This unit is equipped with hermetic rotary Scroll compressors, with R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in Peraluman and base in galvanised sheet steel with paint finish. The range includes twocompressor and four-compressor versions, both with two independent refrigerant circuits. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 198 UNIQUE PROPOSAL Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting TOTAL VERSATILITY Climaveneta is the only company to offer all-in-one units with Scroll compressors in 3 versions designed to satisfy all service system and application requirements CUTTING-EDGE ELECTRONICS The Energy Raiser units are fitted with an evolved electronic unit that allows fully automatic management of the best type of operation to meet the load requirements VENTILATION CONTROL FOR LOW-TEMPERATURE OPERATION The standard units come fitted with pressure-operated control of ventilation, which allows the unit to produce cold water with an external air temperature down to -10°C INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, available for both plant and recovery circuits (up to 4 pumps). Main accessories UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊRubber anti-vibration mounting kit 4 PIPE PLATES SCROLL AXIAL r HFC R-410A SYSTEM NECS-Q / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 0152 0182 0202 0252 0262 0302 0412 0512 kW kW 36,6 13,3 2,76 43,2 14,5 2,99 48,5 17,9 2,71 55,8 19,9 2,80 61,2 22,8 2,68 73,3 26,2 2,80 94,8 33,6 2,82 120 41,7 2,88 kW kW 41,1 13,3 3,10 48,9 14,7 3,33 55,3 17,2 3,22 62,5 19,7 3,17 68,1 21,4 3,18 83,1 24,9 3,34 107 32,1 3,34 136 40 3,40 kW kW kW - 37,2 49,2 12,8 6,75 43,6 56,9 14,2 7,08 50,6 66,2 16,6 7,04 57,2 75 18,9 6,99 64,1 83,8 21 7,04 76,3 99,3 24,5 7,17 97,7 128 31,9 7,08 124 161 39,6 7,20 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 84 52 84 52 84 52 84 52 84 52 85 53 86 54 87 55 2020 1300 1620 570 2020 1300 1620 590 2020 1300 1620 600 2520 1300 1620 660 2520 1300 1620 670 2520 1300 1620 720 3070 1300 1620 1030 3570 1300 1620 1180 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 151 56,6 2,66 150 58,9 2,54 166 69 2,41 189 75,8 2,49 211 85,2 2,48 240 95,6 2,51 277 107 2,58 311 121 2,58 kW kW 173 52,1 3,31 167 58 2,88 185 64,9 2,86 209 72,1 2,90 234 79,8 2,93 267 92 2,90 306 104 2,94 344 116 2,96 kW kW kW - 160 208 51,3 7,17 151 198 49,8 7,01 173 226 57,1 6,99 194 255 64,5 6,96 220 288 72,1 7,05 246 321 79,8 7,11 281 368 92,8 6,99 317 415 105 6,97 N. 2/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 87 55 92 60 92 60 92 60 93 61 94 62 95 63 95 63 3570 1300 1620 1290 3110 2220 2150 1600 3110 2220 2150 1840 3110 2220 2150 2120 4110 2220 2150 2320 4110 2220 2150 2480 4110 2220 2150 2680 4110 2220 2150 2860 dB(A) dB(A) mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 199 NECS-Q / LN Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 0604 0704 0804 0904 1004 1104 1204 kW kW 143 58,8 2,43 157 70,2 2,24 177 78,4 2,26 199 87,8 2,27 227 96,5 2,36 261 110 2,37 291 125 2,32 kW kW 160 54 2,95 176 60,8 2,89 198 67,9 2,92 225 75,7 2,98 254 85,8 2,95 290 97,9 2,96 324 110 2,94 kW kW kW - 151 198 49,8 7,01 173 226 57,1 6,99 194 255 64,5 6,96 220 288 72,1 7,05 246 321 79,8 7,11 281 368 92,8 6,99 317 415 105 6,97 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 86 54 86 54 86 54 87 55 88 56 89 57 89 57 3110 2220 2150 1600 3110 2220 2150 1840 3110 2220 2150 2120 4110 2220 2150 2320 4110 2220 2150 2480 4110 2220 2150 2680 4110 2220 2150 2860 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 200 NECS-Q / SL Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 0152 0182 0202 0252 0262 0302 0412 0512 kW kW 33,3 15 2,21 39,6 16,5 2,39 47 18,7 2,52 50,9 22,4 2,28 58,3 24,4 2,39 69,1 28,4 2,43 93,9 34,1 2,75 119 42,3 2,81 kW kW 40 13,1 3,04 47,4 14,6 3,24 55,1 17,2 3,21 60,9 19,7 3,10 70,5 21,5 3,28 80,9 24,8 3,26 109 32,2 3,38 138 40,1 3,43 kW kW kW - 37,2 49,2 12,8 6,75 43,6 56,9 14,2 7,08 50,6 66,2 16,6 7,04 57,2 74,9 18,9 6,99 64,1 83,8 21 7,04 76,3 99,3 24,5 7,17 97,7 128 31,9 7,08 124 161 39,6 7,20 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 78 46 78 46 79 47 79 47 79 47 80 48 82 50 83 51 2020 130 1620 570 2020 1300 1620 590 2520 1300 1620 660 2520 1300 1620 660 2520 1300 1620 700 3070 1300 1620 780 3070 1300 1620 1070 3570 1300 1620 1230 0612 0604 0704 0804 0904 1004 1104 1204 kW kW 143 60,4 2,37 142 58 2,45 160 67,4 2,37 183 75,5 2,43 201 87,3 2,30 225 95,5 2,36 261 108 2,41 294 123 2,38 kW kW 169 52 3,26 159 52,6 3,02 178 59,5 2,99 205 68,7 2,99 226 76,1 2,98 253 83,8 3,02 295 96,1 3,07 330 110 3 kW kW kW - 160 208 51,3 7,17 151 198 49,8 7,01 173 226 57,1 6,99 194 255 64,5 6,96 220 288 72,1 7,05 246 321 79,8 7,11 281 368 92,8 6,99 317 415 105 6,97 N. 2/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 83 51 82 50 82 50 83 51 83 51 83 51 85 53 86 54 3570 1300 1620 1290 3110 2220 2150 1700 3110 2220 2150 1960 4110 2220 2150 2350 4110 2220 2150 2420 4110 2220 2150 2590 5110 2220 2150 2950 5110 2220 2150 3100 dB(A) dB(A) mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. Minimum clearance required 0152-1204 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 H H A B A B 201 INTEGRA NECS-Q 1314÷3218 Versions B CA SL-CA base version Class A of efficiency Super Low noise version, Class A of efficiency Features INTEGRA unit for 4-pipe systems, air source for outdoor installation 353 - 823 kW Unit Description Multi-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. This unit is equipped with hermetic rotary Scroll compressors, with R410A, axial fans, shell and tube heat exchangers and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 202 REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) UNIQUE PROPOSAL Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting ENERGY SAVING Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be CLASS A EFFICIENCY The full range is also available with the Class A efficiency rating. NECS-Q/CA and NECS-Q/SL-CA guaranty premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans, available on both standard and low-noise versions. INTEGRATED HYDRONIC MODULE The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving low or high head, available for both hot and cold water distribution systems (up to 4 pumps). Main accessories UÊRemote keyboard (distance to 200m and to 500m) UÊSoft starters UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊLT kit for extending the operating limits in heat pump mode down to -10°C (/SL-CA versions) and -12°C (/CA versions) 4 PIPE ENERGY CLASS SHELL & TUBES SCROLL AXIAL SYSTEM NECS-Q / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 353 125 2,81 378 131 2,89 412 150 2,75 452 163 2,77 494 176 2,82 546 189 2,89 567 196 2,89 617 225 2,74 662 235 2,82 704 250 2,81 757 262 2,89 791 281 2,82 823 300 2,74 kW kW 380 121 3,13 408 129 3,18 447 142 3,16 485 156 3,11 528 169 3,12 587 186 3,16 612 192 3,18 670 212 3,16 704 225 3,12 761 243 3,13 817 256 3,18 855 270 3,17 893 283 3,16 kW kW kW - 355 455 107 7,57 379 485 113 7,65 423 542 126 7,66 460 590 139 7,55 500 640 150 7,60 547 700 163 7,65 569 728 170 7,63 636 814 189 7,67 667 854 200 7,61 711 912 213 7,62 758 971 227 7,62 802 240 1027 1,01 848 1085 252 7,67 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 96 64 96 64 96 64 96 64 97 65 97 65 97 65 98 66 98 65 98 65 99 66 99 66 99 66 3905 2260 2450 3530 3905 2260 2450 3620 3905 2260 2450 3650 4515 2260 2450 4850 5690 2260 2450 5240 5690 2260 2450 5370 5690 2260 2450 5430 5690 2260 2450 5480 7430 2260 2450 6700 7430 2260 2450 6830 7430 2260 2450 7000 7430 2260 2450 7030 7430 2260 2450 7060 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. NECS-Q / CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 362 122 2,96 387 128 3,03 425 145 2,94 471 157 3,01 524 173 3,04 559 185 3,03 581 192 3,03 637 217 2,94 680 230 2,95 724 244 2,96 775 256 3,03 813 272 2,99 850 289 2,94 kW kW 394 120 3,30 420 127 3,31 462 140 3,30 507 155 3,28 546 166 3,29 603 183 3,30 630 190 3,32 693 210 3,30 729 221 3,29 788 2394 3,29 840 253 3,32 882 266 3,31 924 280 3,30 kW kW kW - 355 394 107 7,00 379 485 113 7,65 423 542 126 7,66 460 590 139 7,55 500 640 150 7,60 547 700 163 7,65 569 728 170 7,63 636 814 189 7,67 667 854 200 7,61 711 912 213 7,62 758 971 227 7,62 802 1027 240 7,62 848 1085 252 7,67 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 97 65 97 65 97 65 97 64 98 65 98 65 98 65 99 66 99 66 99 66 100 67 100 67 100 67 5080 2260 2450 3850 5080 2260 2450 3950 5080 2260 2450 3980 6255 2260 2450 5460 7430 2260 2450 5740 7430 2260 2450 5890 7430 2260 2450 5970 7430 2260 2450 6020 9780 2260 2450 7350 9780 2260 2450 7500 9780 2260 2450 7700 9780 2260 2450 7740 9780 2260 2450 7770 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 203 NECS-Q / SL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218 kW kW 332 130 2,56 357 137 2,61 398 153 2,60 429 169 2,54 500 640 2,52 512 198 2,59 536 205 2,61 596 230 2,60 616 244 2,52 663 260 2,55 715 274 2,61 754 290 2,60 795 306 2,60 kW kW 378 116 3,25 400 124 3,22 453 138 3,29 486 151 3,22 526 163 3,23 578 178 3,25 601 186 3,23 679 207 3,28 701 217 3,23 755 233 3,24 801 248 3,23 859 262 3,28 906 276 3,28 kW kW kW - 355 455 107 7,57 379 485 113 7,65 423 542 126 7,66 460 590 139 7,55 500 640 150 7,60 547 700 163 7,65 569 728 170 7,63 636 814 189 7,67 667 854 200 7,61 711 912 213 7,62 758 971 227 7,62 802 240 1027 1,01 848 1085 252 7,67 N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4 88 56 88 56 88 56 89 57 89 57 90 57 90 57 91 58 91 58 91 58 92 59 92 59 92 59 4515 2260 2450 3760 5080 2260 2450 3900 5080 2260 2450 4050 5690 2260 2450 5350 5690 2260 2450 5490 6865 2260 2450 5780 7430 2260 2450 5890 7430 2260 2450 6130 7430 2260 2450 7020 8605 2260 2450 7330 9780 2260 2450 7600 9780 2260 2450 7750 9780 2260 2450 7910 dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. Minimum clearance required 1314-3218 Switchboard side Switchboard opposite side Plant exchagers opposite side Plant exchagers side mm mm mm mm 1500 1500 1500 2000 H B 204 A 205 INTEGRA ERACS2-Q 1062÷3222 Versions CA LN-CA SL-CA XL-CA XL-CA-E Class A of efficiency Low Noise, Class A of efficiency Super Low noise version, Class A of efficiency eXtra Low noise version, Class A of efficiency eXtra Low noise, Class A enhanced Features INTEGRA unit for 4-pipe systems, air source for outdoor installation 200 - 826 kW Unit Description Multi-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Each circuit works with a semi-hermetic screw compressor using R134a, two shell and tubes heat exchangers shared by both circuits, a cold heat exchanger on plants side that acts as an evaporator in the production of cold water, a heat exchanger on plants side that works as a condenser in the production of hot water, and a source side coil heat exchanger that works as either condenser or evaporator as required by the loads. Commands W3000 large The controller W3000 large offers the latest control and functions specially developed for these units. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. These resources permit to diirectly act on the unit settings through a multilevel menu, available in several languages. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. For multi-units plants a special device to coordinate and manage all the resources is available as an option; energy metering device is even possible as an option. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 206 UNIQUE PROPOSAL Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting ENERGY SAVING Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be EXTENSIVE RANGE OF OPERATION Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer. VERSION ´XL-CA-E´ AVAILABLE Exclusive Premium version. Together for the first time, the lowest noise level on the market and the maximum efficiency in each operating mode. HOT WATER SUPPLY Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions Main accessories UÊHydronic group UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation UÊElectronic expansion valve UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards SHELL & TUBES SCREW AXIAL 4 PIPE r HFC R-134a SYSTEM ERACS2-Q / CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 kW kW 210 72,1 2,91 248 84,5 2,93 302 102 2,96 329 109 3,02 380 129 2,95 425 144 2,95 483 156 3,10 525 167 3,14 554 176 3,15 624 201 3,10 701 222 3,16 826 264 3,13 kW kW 218 67 3,25 258 80,7 3,20 309 92,2 3,35 339 101 3,36 396 122 3,25 434 131 3,31 492 149 3,30 541 159 3,40 571 169 3,38 615 178 3,46 711 207 3,43 826 240 3,44 kW kW kW - 209 269 60,6 7,89 248 320 71,9 7,90 305 392 87,1 8,00 329 422 92,5 8,12 381 493 111 7,87 428 549 122 8,01 484 621 137 8,07 521 666 145 8,19 551 704 153 8,20 631 801 170 8,42 702 895 193 8,27 832 1056 224 8,43 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 97 65 97 65 97 65 98 66 99 67 99 67 99 67 101 69 101 69 101 69 101 69 102 70 4610 2220 2150 * 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. ERACS2-Q / LN-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 kW kW 205 70,8 2,90 241 84,3 2,86 294 103 2,85 322 109 2,95 369 130 2,84 414 144 2,88 469 163 2,88 513 168 3,05 541 177 3,06 604 206 2,93 686 226 3,04 800 274 2,92 kW kW 218 67 3,25 258 80,7 3,20 309 92,2 3,35 339 101 3,36 396 122 3,25 434 131 3,31 492 149 3,30 541 159 3,40 571 169 3,38 615 178 3,46 711 207 3,43 826 240 3,44 kW kW kW - 209 269 60,6 7,89 248 320 71,9 7,90 305 392 87,1 8,00 329 422 92,5 8,12 381 493 111 7,87 428 549 122 8,01 484 621 137 8,07 521 666 145 8,19 551 704 153 8,20 631 801 170 8,42 702 895 193 8,27 832 1056 224 8,43 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 90 58 91 59 91 59 92 60 92 60 92 60 93 61 95 63 95 63 95 63 95 63 96 64 4610 2220 2150 * 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 207 ERACS2-Q / SL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222 kW kW 200 72,7 2,75 233 87,2 2,67 283 109 2,60 314 113 2,78 356 137 2,60 401 149 2,69 464 166 2,80 509 170 2,99 537 180 2,98 597 210 2,84 680 229 2,97 790 281 2,81 kW kW 211 64,8 3,26 251 78,4 3,20 301 89,9 3,35 330 98,4 3,35 385 119 3,24 422 127 3,32 486 147 3,31 536 157 3,41 564 167 3,38 607 176 3,45 703 205 3,43 816 238 3,43 kW kW kW - 209 269 60,6 7,89 248 320 71,9 7,90 305 392 87,1 8,00 329 422 92,5 8,12 381 493 111 7,87 428 549 122 8,01 484 621 137 8,07 521 666 145 8,19 551 704 153 8,20 631 801 170 8,42 702 895 193 8,27 832 1056 224 8,43 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 86 54 87 55 87 55 88 56 88 56 88 56 89 57 91 59 91 59 91 59 91 59 92 60 4610 2220 2150 * 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. ERACS2-Q / XL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 2022 2222 2422 2622 2722 3222 kW kW 455 167 2,72 501 169 2,96 528 180 2,93 584 212 2,75 667 230 2,90 772 287 2,69 kW kW 486 143 3,40 536 152 3,53 564 161 3,50 607 170 3,57 703 198 3,55 816 230 3,55 kW kW kW - 484 621 137 8,07 521 666 145 8,19 551 704 153 8,20 631 801 170 8,42 702 895 193 8,27 832 1056 224 8,43 N. 2/2 2/2 2/2 2/2 2/2 2/2 85 53 87 55 87 55 87 55 87 55 88 56 6300 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 7200 2260 2350 * 8400 2260 2350 * 9700 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 208 ERACS2-Q / XL-CA-E Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 1062 1162 1362 1562 1762 2022 2222 2422 2622 kW kW 204 66,6 3,06 247 76,6 3,22 293 99,4 2,95 319 105 3,04 366 127 2,88 473 153 3,09 510 163 3,13 541 169 3,20 611 193 3,17 kW kW 218 62,4 3,49 267 77,6 3,44 308 88,3 3,49 340 95,2 3,57 393 116 3,39 513 145 3,54 552 154 3,58 588 164 3,59 644 176 3,66 kW kW kW - 209 269 60,6 7,89 248 320 71,9 7,90 305 392 87,1 8,00 329 422 92,5 8,12 381 493 111 7,87 484 621 137 8,07 521 666 145 8,19 551 704 153 8,20 631 801 170 8,42 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 85 53 86 54 86 54 87 55 87 55 86 54 88 56 88 56 88 56 4610 2220 2420 * 5610 2220 2430 * 5610 2220 2430 * 6610 2220 2430 * 6610 2220 2430 * 8400 2260 2350 * 9300 2260 2350 * 9300 2260 2350 * 9300 2260 2350 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. Minimum clearance required 1062-1762 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1100 1100 2000 2022-2622 1800 1500 2000 209 INTEGRA i-FX-Q 0502÷0802 Versions CA LN-CA SL-CA Class A of efficiency Low Noise, Class A of efficiency Super Low noise version, Class A of efficiency Features INTEGRA unit for 4-pipe systems, air source for outdoor installation 479 - 811 kW Unit Description Multi-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Each circuit works with an inverter driven semi-hermetic screw compressor using R134a, two shell and tubes heat exchangers shared by both circuits, a cold heat exchanger and a hot one on plants side, and a source side coil heat exchanger that works as either condenser or evaporator as required by the loads. The revolutionary units design, patent pending, and the use of inverter motors on compressors, fans and, on request, on pumps, ensures un umbeatable efficiency, specially at part load. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits and features the continuous modulation of capacity by adjustment of the compressor speed. The modulation is based on PID algorithms and referring to the leaving water temperature. This is combined with the management of the compressors status, with two selectable logics (proportional referred to the return temperature or dead band referred to the leaving temperature). This allows to satisfy simultaneously and accurately the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 210 UNIQUE PROPOSAL - PATENT PENDING The exclusive regulation´s logic of the INTEGRA units, the only able to satisfy cold and hot building loads simultaneously, and the use of inverter motors ensure the highest energy saving for complex plants, as the 4-pipes system are VERY HIGH EFFICIENCY AT PARTIAL LOAD Very high efficiency at partial load thanks to the inverter technology applied on screw compressors. Therefore, operating costs are reduced to a minimum TRUE SILENCE Silence optimized for the most frequent operational conditions, thanks to the accurate structures design, to the use of EC fans (DC brushless) and to the adoption of variable-speed driven compressors EXTENSIVE RANGE OF OPERATION Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer. HARMONY BETWEEN UNIT AND PLANT Low inrush current and cos(phi) higher than 0.9, permit an easy electrical installation which is not stressed during start-up and with no need of extra devices for power factor correction. The use of inverter allows the unit partialize down to 15%, with consequent lower fluctuations of leaving water temperature Main accessories UÊHydronic group UÊVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards SHELL & TUBES SCREW EC FAN 4 PIPE r HFC R-134a SYSTEM i-FX-Q / CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 0502 0602 0702 0802 kW kW 498 164 3,04 617 210 2,94 711 245 2,90 811 273 2,97 kW kW 528 155 3,41 654 194 3,37 758 224 3,38 856 249 3,44 kW kW kW - 485 624 147 7,54 613 787 185 7,57 715 917 215 7,59 814 1040 240 7,72 N. 2/2 2/2 2/2 2/2 * * * * * * * * 7800 2260 2430 * 9000 2260 2430 * 9000 2260 2430 * 9900 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. i-FX-Q / LN-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 0502 0602 0702 0802 kW kW 484 159 3,04 599 206 2,91 690 243 2,84 787 271 2,90 kW kW 528 155 3,41 654 194 3,37 758 224 3,38 856 249 3,44 kW kW kW - 485 624 147 7,54 613 787 185 7,57 715 917 215 7,59 814 1040 240 7,72 N. 2/2 2/2 2/2 2/2 * * * * * * * * 7800 2260 2430 * 9000 2260 2430 * 9000 2260 2430 * 9900 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 211 i-FX-Q / SL-CA Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (5) Sound pressure (6) SIZE A B H Operating weight 0502 0602 0702 0802 kW kW 479 158 3,03 592 207 2,86 681 245 2,78 777 273 2,85 kW kW 523 152 3,44 649 191 3,40 750 220 3,41 847 244 3,47 kW kW kW - 485 624 147 7,54 613 787 185 7,57 715 917 215 7,59 814 1040 240 7,72 N. 2/2 2/2 2/2 2/2 * * * * * * * * 7800 2260 2430 * 9000 2260 2430 * 9000 2260 2430 * 9900 2260 2430 * dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. 2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%. 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. Minimum clearance required 0502-0802 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1800 1500 2000 212 213 INTEGRA NECS-WQ 0152÷1604 Versions B base version Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0) INTEGRATED CONDENSATION´S CONTROL A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request. ENERGY SAVING Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be HOT WATER SUPPLY Production of hot water up to 54°C to meet the most demanding application needs. INTEGRA unit for 4-pipe systems, water source 45,7 - 491 kW Unit Description Multi-purpose indoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent water circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching. Water-source unit equipped with hermetic rotary Scroll compressors, with R410A, plate heat exchangers and thermostatic expansion valve. The range is composed by units equipped with two and four compressors, all with two independent refrigerant circuits. Commands W3000 large The controller W3000 large offers the latest control and functions developed directly by Climaveneta on the basis of their experience gained over the years with these particular units and the related plant engineering. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 214 Main accessories UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board UÊAcoustical enclosure to reduce the noise emissions. UÊWater connections directed upwards (for 2 compressors units only) 4 PIPE r HFC R-410A SCROLL PLATES SYSTEM NECS-WQ / B Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Total power input Sound power (5) Sound pressure (6) SIZE A (7) B (7) H (7) Operating weight (7) 0152 0182 0202 0252 0262 0302 0412 0512 0612 kW kW 48,6 8,70 5,59 55,8 9,80 5,69 65 11,3 5,75 73,8 13,2 5,59 83,2 14,7 5,66 97,5 17,4 5,60 127 22,7 5,59 159 28,1 5,64 206 36,5 5,63 kW kW 52,1 12,4 4,20 59,7 13,8 4,33 69,3 16,2 4,28 79 18,5 4,28 88,9 20,4 4,36 104 23,9 4,37 135 31 435 169 38,4 4,40 219 49,9 4,38 kW kW kW - 40,4 52,1 12,4 7,46 46,7 59,7 13,8 7,71 54,1 69,3 16,2 7,62 61,7 79 18,5 7,61 67,9 88,9 20,4 7,69 82 104 23,9 7,78 106 135 31 7,77 133 169 38,4 7,86 172 219 49,9 7,84 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 73 42 74 43 74 43 74 43 75 44 76 45 77 46 78 47 79 48 1222 893 1496 450 1222 893 1496 470 1222 893 1496 490 1222 893 1496 505 1222 893 1496 525 1222 893 1496 550 1222 893 1496 745 1222 893 1496 825 1222 893 1496 910 0604 0704 0804 0904 1004 1104 1204 1404 1604 kW kW 194 34,8 5,58 225 40 5,63 255 45,3 5,62 285 50,8 5,61 317 56,3 5,63 365 64,8 5,63 413 73 5,66 468 84,1 5,56 522 95,1 5,49 kW kW 208 47,7 4,36 240 54,7 4,38 270 61,8 4,37 303 69,2 4,38 338 76,8 4,40 388 88,4 4,39 440 99,6 4,41 498 113 4,41 557 126 4,42 kW kW kW - 163 208 47,7 7,78 188 240 54,7 7,82 212 270 61,8 7,80 238 303 69,2 7,82 266 338 76,8 7,86 305 388 88,4 7,84 346 440 99,6 7,89 392 498 113 7,88 438 557 126 7,90 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 86 54 87 55 88 56 89 57 90 58 91 59 91 59 91 59 91 59 2520 880 1810 975 2520 880 1810 1165 2520 880 1810 1365 2520 880 1810 1445 2520 880 1810 1610 2520 880 1810 1710 2520 880 1810 1810 2520 880 1810 1895 2520 880 1810 2000 kW dB(A) dB(A) mm mm mm kg Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Total power input Sound power (5) Sound pressure (6) SIZE A (7) B (7) H (7) Operating weight (7) kW dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C 2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 1 m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 7 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0152-0612 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 0604-1604 800 800 800 H 1000 1000 800 H B A B A 215 INTEGRA ERACS2-WQ 0802÷3202 Versions - base version Features UNIQUE PROPOSAL Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting ENERGY SAVING Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be EXTENSIVE RANGE OF OPERATION Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions INTEGRATED CONDENSATION´S CONTROL A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request. INTEGRA unit for 4-pipe systems, water source 194 - 891 kW Unit Description Multi-purpose indoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent water circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching. Each circuit works with a semi-hermetic screw compressor using R134a, and three tube nest heat exchangers, a cold exchanger on the user side shared by both circuits that acts as an evaporator in the production of cold water, a heat exchanger on the user side that words as a condenser in the production of hot water, and a source side exchanger that works as either condenser or evaporator as required by the loads. Commands W3000SE Large The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 216 Main accessories UÊIntegral acoustical enclosure (type base or plus) UÊSeveral devices for condensation´s control UÊElectronic expansion valve UÊSet-up for remote connectivity with ModBus/Echelon/ Bacnet protocol cards SCREW SHELL & TUBES 4 PIPE r HFC R-134a SYSTEM ERACS2-WQ / Models COOLING ONLY Cooling capacity (1) Total power input (1) EER HEATING ONLY Heating capacity (2) Total power input (2) COP COOLING WITH TOTAL RECOVERY Cooling capacity (3) Heat recovery capacity (3) Total power input (3) TER (4) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Total power input Sound power (5) Sound pressure (6) SIZE A (7) B (7) H (7) Operating weight (7) 0802 1002 1102 1302 1502 1702 1902 2152 2502 2602 2702 3202 kW kW 194 34,3 5,66 240 43,2 5,56 275 48,5 5,66 326 57,2 5,69 373 66,1 5,64 435 76,5 5,68 479 85,7 5,58 554 94,5 5,87 648 111 5,83 703 121 5,83 781 135 5,80 891 153 5,81 kW kW 205 45,7 4,49 255 57 4,47 291 65,9 4,42 344 76,3 4,51 393 86,9 4,52 459 103 4,44 514 117 4,40 589 128 4,59 686 149 4,62 738 158 4,68 831 180 4,62 941 205 4,59 kW kW kW - 162 205 45,7 8,03 201 255 57 8,00 229 291 65,9 7,89 272 344 76,3 8,07 311 393 86,9 8,10 362 459 103 7,97 404 514 117 7,85 468 589 128 8,26 547 686 149 8,28 589 738 158 8,40 662 831 180 8,29 748 941 205 8,24 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 94 76 95 77 97 79 97 79 97 79 97 79 97 78 98 79 99 80 99 80 99 80 99 80 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3680 1170 1950 * 3800 1490 1950 * 3800 1490 1950 * 3800 1490 1950 * 5000 1490 2050 * 5000 1490 2050 * 5000 1490 2050 * kW dB(A) dB(A) mm mm mm kg Note: 1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C 2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C 3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C 4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input) 5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 6 Average sound pressure level, at 1 m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 7 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0802-3202 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 800 500 500 217 RONIC N TEEER 218 219 hydronic terminals RMINALS hydronic terminals Hydronic terminals a-LIFE 120÷840 Versions DFI DFU DLI DLU built-in version, front air intake version with cabinet, front air intake built-in version, bottom air intake version with cabinet, bottom air intake Features Low noise centrifugal fan, with double intake and forward blade; Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil); 6-speed autotransformer; Air filter on all models; Cabinet in galvanised steel with prevarnished finish for maximum resistance to rust; Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40); Main accessories Fan-coil for professional applications, with cabinet or built-in version 1,45 - 11,9 kW Unit Description a-LIFE fan-coil has been specifically developed to adapt to every ambient thanks to its modern and minimal design, which is a result of the full experience and know-how Climaveneta has in this range of products. Commands NS plug-in/NSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PS plug-in/PSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MT plug-in/MTW wall mounted Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/ winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. AT plug-in/ATW wall mounted Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. 220 UÊHot water coil kit 1 row and 2 rows UÊKit RS485 - interface for Building Management System UÊKit control board to manage 0-10V or 3 points modulating valve unit UÊMain coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-way UÊAdditional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way UÊKit LIFE BOX UÊStraight and angular (90°) plenum kits for air inlet UÊStraight and angular (90°) plenum kits for air outlet UÊPlenum kit with round air ducts for plenum kit UÊElectric heaters CONTROLLER 4 PIPES CENTRIFUGAL FAN COIL 2 PIPES a-LIFE / DLU Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P Weight 120 130 140 220 230 240 320 330 340 420 430 m3/h m3/h m3/h m3/h m3/h m3/h 430 390 330 290 220 180 410 360 315 270 200 175 390 340 290 250 180 160 500 430 365 310 240 210 480 410 350 300 225 200 450 380 320 270 210 180 510 440 375 320 250 220 485 415 355 305 230 205 460 390 330 280 220 190 830 700 580 480 330 280 815 680 565 470 315 270 kW kW kW kW kW kW 1,45 1,37 1,24 1,14 0,96 0,84 1,91 1,75 1,59 1,42 1,11 0,97 2,32 2,10 1,87 1,67 1,27 1,16 2,13 1,93 1,72 1,53 1,26 1,13 2,67 2,37 2,10 1,85 1,42 1,23 3,20 2,81 2,46 2,13 1,71 1,48 2,76 2,49 2,23 1,99 1,65 1,49 3,22 2,86 2,53 2,24 1,77 1,59 3,68 3,23 2,79 2,42 1,97 1,64 3,77 3,39 3 2,64 2,02 1,79 4,69 4,14 3,62 3,16 2,31 2,03 kW kW kW kW kW kW l/h kPa 1,36 1,27 1,13 1,03 0,83 0,71 250 12 1,63 1,47 1,32 1,16 0,89 0,78 330 5 1,77 1,58 1,39 1,23 0,93 0,84 400 10 1,89 1,68 1,48 1,30 1,04 0,93 370 6 2,17 1,91 1,67 1,46 1,11 0,97 460 5 2,41 2,09 1,82 1,56 1,24 1,07 550 8 2,26 2,01 1,77 1,56 1,27 1,14 470 11 2,47 2,17 1,90 1,67 1,30 1,17 550 7 2,68 2,34 2,01 1,73 1,40 1,18 630 5 3,25 2,86 2,48 2,15 1,59 1,39 650 19 3,77 3,27 2,82 2,42 1,72 1,50 800 14 kW kW kW kW kW kW l/h kPa 3,25 3,04 2,72 2,49 2,05 1,77 350 10 4,46 4,04 3,66 3,25 2,56 2,30 390 5 5,01 4,49 3,94 3,49 2,64 2,38 440 8 4,77 4,28 3,79 3,36 2,76 2,49 420 5 5,79 5,12 4,51 3,98 3,13 2,83 510 4 6,28 5,44 4,70 4,05 3,24 2,82 550 7 5,40 4,84 4,28 3,79 3,11 2,81 470 9 6,36 5,60 4,92 4,33 3,39 3,07 560 6 6,76 5,85 5,05 4,36 3,50 3,05 590 5 7,68 6,81 5,94 5,16 3,88 3,41 670 16 9,58 8,33 7,19 6,20 4,45 3,90 840 12 kW kW kW kW kW kW l/h kPa 1,98 1,86 1,66 1,52 1,25 1,08 350 11 2,71 2,46 2,22 1,97 1,55 1,39 470 5 3,04 2,72 2,39 2,11 1,60 1,44 530 8 2,91 2,61 2,31 2,04 1,68 1,51 510 5 3,52 3,11 2,74 2,41 1,90 1,72 610 5 3,80 3,30 2,84 2,45 1,96 1,70 660 7 3,29 2,94 2,60 2,30 1,89 1,71 570 10 3,86 3,40 2,98 2,62 2,05 1,85 670 6 4,09 3,54 3,05 2,63 2,09 1,80 710 5 4,69 4,15 3,62 3,14 2,36 2,07 820 17 5,83 5,06 4,37 3,76 2,69 2,36 1020 13 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,87 130 2 1,48 1,37 1,26 1,15 0,95 0,87 130 2 - 2,12 1,92 1,74 1,57 1,30 1,20 190 4 2,12 1,92 1,74 1,57 1,30 1,20 190 4 - 2,48 2,24 2,02 1,82 1,50 1,39 220 7 2,48 2,24 2,02 1,82 1,50 1,39 220 7 - 3,48 3,13 2,78 2,46 1,92 1,72 310 13 3,48 3,13 2,78 2,46 1,92 1,72 310 13 46 41 38 35 30 28 0,50 1C 1/2”G F 46 41 38 35 30 28 0,70 1C 1/2”G F 47 42 39 36 31 29 0,70 1C 1/2”G F 48 44 40 37 30 29 0,70 1C 1/2”G F 48 44 40 37 30 29 1 1C 1/2”G F 49 45 41 38 31 30 1 1C 1/2”G F 48 44 40 37 31 29 1 1C 1/2”G F 48 44 40 37 31 29 1,40 1C 1/2”G F 49 45 41 38 32 30 1,40 1C 1/2”G F 51 47 43 41 33 30 1 2C 1/2”G F 51 47 43 41 33 30 1,40 2C 1/2”G F 732 541 233 18 732 541 233 18 732 541 233 18 922 541 233 22 922 541 233 22 922 541 233 22 1112 541 233 26 1112 541 233 26 1112 541 233 26 1112 541 233 28 1112 541 233 28 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 66 66 66 77 77 77 93 93 93 130 130 A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg 221 Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P Weight 440 520 530 540 620 630 640 720 730 740 m3/h m3/h m3/h m3/h m3/h m3/h 790 660 454 455 300 260 950 815 710 610 460 400 915 780 680 585 440 390 880 750 655 560 420 380 940 810 710 600 460 410 925 790 685 590 445 400 900 770 670 560 440 390 1360 1150 970 790 640 480 1310 1090 920 740 590 440 1260 1070 880 700 570 430 kW kW kW kW kW kW 5,57 4,87 4,22 3,65 2,56 2,28 4,66 4,21 3,84 3,45 2,81 2,52 5,75 5,13 4,65 4,15 3,36 3,05 6,54 5,80 5,26 4,63 3,66 3,38 5,18 4,68 4,26 3,77 3,09 2,83 6,92 6,16 5,53 4,88 3,90 3,58 7,47 6,57 5,84 5,08 4,14 3,71 6,59 5,92 5,29 4,60 3,96 3,20 8,94 7,81 6,89 5,87 4,88 3,87 9,64 8,54 7,30 6,02 5,13 4,03 kW kW kW kW kW kW l/h kPa 4,20 3,62 3,10 2,66 1,84 1,63 960 11 3,95 3,51 3,15 2,79 2,22 1,97 800 11 4,50 3,96 3,54 3,12 2,48 2,24 990 22 4,86 4,27 3,84 3,35 2,61 2,40 1120 18 4,23 3,76 3,38 2,95 2,37 2,15 890 16 5,13 4,52 4,03 3,53 2,78 2,54 1190 18 5,40 4,72 4,17 3,59 2,82 2,50 1280 14 5,61 4,94 4,33 3,68 3,11 2,45 1130 24 6,81 5,86 5,11 4,30 3,53 2,75 1530 27 7,12 6,24 5,28 4,31 3,63 2,82 1650 23 kW kW kW kW kW kW l/h kPa 10,7 9,18 7,81 6,69 4,63 4,07 930 10 9,92 8,86 7,98 7,11 5,70 5,09 870 10 11,2 9,88 8,85 7,83 6,18 5,58 980 19 12,3 10,7 9,56 8,34 6,47 5,91 1080 15 10,8 9,61 8,68 7,61 6,15 5,59 950 14 13,1 11,4 10,1 8,88 6,91 6,28 1150 11 13,5 11,8 10,4 8,85 7,09 6,33 1190 12 13,7 12,2 10,7 9,16 7,78 6,18 1210 21 17,4 15 13 10,8 8,88 6,84 1530 22 18 15,7 13,3 10,8 8,99 6,94 1580 19 kW kW kW kW kW kW l/h kPa 6,46 5,57 4,73 4,05 2,80 2,46 1130 10 6,04 5,39 4,86 4,32 3,46 3,09 1050 10 6,81 6 5,37 4,75 3,75 3,38 1190 20 7,44 6,50 5,79 5,05 3,91 3,57 1300 16 6,67 5,93 5,33 4,73 3,77 3,36 1160 14 7,93 6,93 6,12 5,37 4,18 3,79 1380 16 8,25 7,19 6,35 5,33 4,19 3,72 1440 12 8,37 7,40 6,52 5,57 4,73 3,75 1460 22 10,6 9,10 7,89 6,55 5,37 4,13 1850 24 11 9,55 8,05 6,57 5,42 4,10 1920 21 kW kW kW kW kW kW l/h kPa - 4,11 3,71 3,40 3,09 2,55 2,35 360 20 4,11 3,71 3,40 3,09 2,55 2,35 360 20 - 4,52 4,09 3,72 3,37 2,78 2,59 400 24 4,52 4,09 3,72 3,37 2,78 2,59 400 24 - 5,62 5,02 4,51 3,92 3,37 2,76 490 35 5,62 5,02 4,51 3,92 3,37 2,76 490 35 - 52 48 44 42 34 31 1 2C 1/2”G F 51 47 44 40 33 30 1,20 2C 1/2”G F 51 47 44 40 33 30 1,80 2C 1/2”G F 52 48 45 42 34 31 1,40 2C 1/2”G F 52 48 45 41 35 33 1,50 2C 1/2”G F 52 48 45 41 35 33 2,20 2C 1/2”G F 53 49 46 42 36 34 2,20 2C 1/2”G F 54 49 46 41 36 33 1,50 3C 1/2”G F 54 49 46 41 36 33 2,20 3C 1/2”G F 55 50 47 42 37 34 2,20 3C 1/2”G F 130 0,57 230-1-50 150 0,60 230-1-50 150 0,60 230-1-50 150 0,60 230-1-50 165 0,73 230-1-50 165 0,73 230-1-50 165 0,73 230-1-50 245 1,10 230-1-50 245 1,10 230-1-50 245 1,10 230-1-50 1112 541 233 28 1302 541 233 32 1302 541 233 32 1302 541 233 32 1492 541 233 38 1492 541 233 38 1492 541 233 38 1492 541 233 43 1492 541 233 43 1492 541 233 43 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W A V-Ph~Hz (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 222 a-LIFE / DFU Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P (5) Weight 120 130 140 220 230 240 320 330 340 420 430 m3/h m3/h m3/h m3/h m3/h m3/h 430 390 330 290 220 180 410 360 315 270 200 175 390 340 290 250 180 160 500 430 365 310 240 210 480 410 350 300 225 200 450 380 320 270 210 180 510 440 375 320 250 220 485 415 355 305 230 205 460 390 330 280 220 190 830 700 580 480 330 280 815 680 565 470 315 270 kW kW kW kW kW kW 1,45 1,37 1,24 1,14 0,96 0,84 1,91 1,75 1,59 1,42 1,11 0,97 2,32 2,10 1,87 1,67 1,27 1,16 2,13 1,93 1,72 1,53 1,26 1,13 2,67 2,37 2,10 1,85 1,42 1,23 3,20 2,81 2,46 2,13 1,71 1,48 2,76 2,49 2,23 1,99 1,65 1,49 3,22 2,86 2,53 2,24 1,77 1,59 3,68 3,23 2,79 2,42 1,97 1,64 3,77 3,39 3 2,64 2,02 1,79 4,69 4,14 3,62 3,16 2,31 2,03 kW kW kW kW kW kW l/h kPa 1,36 1,27 1,13 1,03 0,83 0,71 250 12 1,63 1,47 1,32 1,16 0,89 0,78 330 5 1,77 1,58 1,39 1,23 0,93 0,84 400 10 1,89 1,68 1,48 1,30 1,04 0,93 370 6 2,17 1,91 1,67 1,46 1,11 0,97 460 5 2,41 2,09 1,82 1,56 1,24 1,07 550 8 2,26 2,01 1,77 1,56 1,27 1,14 470 11 2,47 2,17 1,90 1,67 1,30 1,17 550 7 2,68 2,34 2,01 1,73 1,40 1,18 630 5 3,25 2,86 2,48 2,15 1,59 1,39 650 19 3,77 3,27 2,82 2,42 1,72 1,50 800 14 kW kW kW kW kW kW l/h kPa 3,25 3,04 2,72 2,49 2,05 1,77 350 10 4,46 4,04 3,66 3,25 2,56 2,30 390 5 5,01 4,49 3,94 3,49 2,64 2,38 440 8 4,77 4,28 3,79 3,36 2,76 2,49 420 5 5,79 5,12 4,51 3,98 3,13 2,83 510 4 6,28 5,44 4,70 4,05 3,24 2,82 550 7 5,40 4,84 4,28 3,79 3,11 2,81 470 9 6,36 5,60 4,92 4,33 3,39 3,07 560 6 6,76 5,85 5,05 4,36 3,50 3,05 590 5 7,68 6,81 5,94 5,16 3,88 3,41 670 16 9,58 8,33 7,19 6,20 4,45 3,90 840 12 kW kW kW kW kW kW l/h kPa 1,98 1,86 1,66 1,52 1,25 1,08 350 11 2,71 2,46 2,22 1,97 1,55 1,39 470 5 3,04 2,72 2,39 2,11 1,60 1,44 530 8 2,91 2,61 2,31 2,04 1,68 1,51 510 5 3,52 3,11 2,74 2,41 1,90 1,72 610 5 3,80 3,30 2,84 2,45 1,96 1,70 660 7 3,29 2,94 2,60 2,30 1,89 1,71 570 10 3,86 3,40 2,98 2,62 2,05 1,85 670 6 4,09 3,54 3,05 2,63 2,09 1,80 710 5 4,69 4,15 3,62 3,14 2,36 2,07 820 17 5,83 5,06 4,37 3,76 2,69 2,36 1020 13 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,87 130 2 1,48 1,37 1,26 1,15 0,95 0,87 130 2 - 2,12 1,92 1,74 1,57 1,30 1,20 190 4 2,12 1,92 1,74 1,57 1,30 1,20 190 4 - 2,48 2,24 2,02 1,82 1,50 1,39 220 7 2,48 2,24 2,02 1,82 1,50 1,39 220 7 - 3,48 3,13 2,78 2,46 1,92 1,72 310 13 3,48 3,13 2,78 2,46 1,92 1,72 310 13 46 41 38 35 30 28 0,50 1C 1/2”G F 46 41 38 35 30 28 0,70 1C 1/2”G F 47 42 39 36 31 29 0,70 1C 1/2”G F 48 44 40 37 30 29 0,70 1C 1/2”G F 48 44 40 37 30 29 1 1C 1/2”G F 49 45 41 38 31 30 1 1C 1/2”G F 48 44 40 37 31 29 1 1C 1/2”G F 48 44 40 37 31 29 1,40 1C 1/2”G F 49 45 41 38 32 30 1,40 1C 1/2”G F 51 47 43 41 33 30 1 2C 1/2”G F 51 47 43 41 33 30 1,40 2C 1/2”G F 732 541 245 18 732 541 245 18 732 541 245 18 922 541 245 22 922 541 245 22 922 541 245 22 1112 541 245 26 1112 541 245 26 1112 541 245 26 1112 541 245 28 1112 541 245 28 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 66 66 66 77 77 77 93 93 93 130 130 A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg 223 Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P (5) Weight 440 520 530 540 620 630 640 720 730 740 m3/h m3/h m3/h m3/h m3/h m3/h 790 660 454 455 300 260 950 815 710 610 460 400 915 780 680 585 440 390 880 750 655 560 420 380 940 810 710 600 460 410 925 790 685 590 445 400 900 770 670 560 440 390 1360 1150 970 790 640 480 1310 1090 920 740 590 440 1260 1070 880 700 570 430 kW kW kW kW kW kW 5,57 4,87 4,22 3,65 2,56 2,28 4,66 4,21 3,84 3,45 2,81 2,52 5,75 5,13 4,65 4,15 3,36 3,05 6,54 5,80 5,26 4,63 3,66 3,38 5,18 4,68 4,26 3,77 3,09 2,83 6,92 6,16 5,53 4,88 3,90 3,58 7,47 6,57 5,84 5,08 4,14 3,71 6,59 5,92 5,29 4,60 3,96 3,20 8,94 7,81 6,89 5,87 4,88 3,87 9,64 8,54 7,30 6,02 5,13 4,03 kW kW kW kW kW kW l/h kPa 4,20 3,62 3,10 2,66 1,84 1,63 960 11 3,95 3,51 3,15 2,79 2,22 1,97 800 11 4,50 3,96 3,54 3,12 2,48 2,24 990 22 4,86 4,27 3,84 3,35 2,61 2,40 1120 18 4,23 3,76 3,38 2,95 2,37 2,15 890 16 5,13 4,52 4,03 3,53 2,78 2,54 1190 18 5,40 4,72 4,17 3,59 2,82 2,50 1280 14 5,61 4,94 4,33 3,68 3,11 2,45 1130 24 6,81 5,86 5,11 4,30 3,53 2,75 1530 27 7,12 6,24 5,28 4,31 3,63 2,82 1650 23 kW kW kW kW kW kW l/h kPa 10,7 9,18 7,81 6,69 4,63 4,07 930 10 9,92 8,86 7,98 7,11 5,70 5,09 870 10 11,2 9,88 8,85 7,83 6,18 5,58 980 19 12,3 10,7 9,56 8,34 6,47 5,91 1080 15 10,8 9,61 8,68 7,61 6,15 5,59 950 14 13,1 11,4 10,1 8,88 6,91 6,28 1150 11 13,5 11,8 10,4 8,85 7,09 6,33 1190 12 13,7 12,2 10,7 9,16 7,78 6,18 1210 21 17,4 15 13 10,8 8,88 6,84 1530 22 18 15,7 13,3 10,8 8,99 6,94 1580 19 kW kW kW kW kW kW l/h kPa 6,46 5,57 4,73 4,05 2,80 2,46 1130 10 6,04 5,39 4,86 4,32 3,46 3,09 1050 10 6,81 6 5,37 4,75 3,75 3,38 1190 20 7,44 6,50 5,79 5,05 3,91 3,57 1300 16 6,67 5,93 5,33 4,73 3,77 3,36 1160 14 7,93 6,93 6,12 5,37 4,18 3,79 1380 16 8,25 7,19 6,35 5,33 4,19 3,72 1440 12 8,37 7,40 6,52 5,57 4,73 3,75 1460 22 10,6 9,10 7,89 6,55 5,37 4,13 1850 24 11 9,55 8,05 6,57 5,42 4,10 1920 21 kW kW kW kW kW kW l/h kPa - 4,11 3,71 3,40 3,09 2,55 2,35 360 20 4,11 3,71 3,40 3,09 2,55 2,35 360 20 - 4,52 4,09 3,72 3,37 2,78 2,59 400 24 4,52 4,09 3,72 3,37 2,78 2,59 400 24 - 5,62 5,02 4,51 3,92 3,37 2,76 490 35 5,62 5,02 4,51 3,92 3,37 2,76 490 35 - 52 48 44 42 34 31 1 2C 1/2”G F 51 47 44 40 33 30 1,20 2C 1/2”G F 51 47 44 40 33 30 1,80 2C 1/2”G F 52 48 45 42 34 31 1,40 2C 1/2”G F 52 48 45 41 35 33 1,50 2C 1/2”G F 52 48 45 41 35 33 2,20 2C 1/2”G F 53 49 46 42 36 34 2,20 2C 1/2”G F 54 49 46 41 36 33 1,50 3C 1/2”G F 54 49 46 41 36 33 2,20 3C 1/2”G F 55 50 47 42 37 34 2,20 3C 1/2”G F 130 0,57 230-1-50 150 0,60 230-1-50 150 0,60 230-1-50 150 0,60 230-1-50 165 0,73 230-1-50 165 0,73 230-1-50 165 0,73 230-1-50 245 1,10 230-1-50 245 1,10 230-1-50 245 1,10 230-1-50 1112 541 245 28 1302 541 245 32 1302 541 245 32 1302 541 245 32 1492 541 245 38 1492 541 245 38 1492 541 245 38 1492 541 245 43 1492 541 245 43 1492 541 245 43 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W A V-Ph~Hz (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 5 Size related to the air inlet grille 224 a-LIFE / DLI Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 120 130 140 220 230 240 320 330 340 420 430 440 m3/h m3/h m3/h m3/h m3/h m3/h 430 390 330 290 220 180 410 360 315 270 200 175 390 340 290 250 180 160 500 430 365 310 240 210 480 410 350 300 225 200 450 380 320 270 210 180 510 440 375 320 250 220 485 415 355 305 230 205 460 390 330 280 220 190 830 700 580 480 330 280 815 680 565 470 315 270 790 660 454 455 300 260 kW kW kW kW kW kW 1,45 1,37 1,24 1,14 0,96 0,84 1,91 1,75 1,59 1,42 1,11 0,97 2,32 2,10 1,87 1,67 1,27 1,16 2,13 1,93 1,72 1,53 1,26 1,13 2,67 2,37 2,10 1,85 1,42 1,23 3,20 2,81 2,46 2,13 1,71 1,48 2,76 2,49 2,23 1,99 1,65 1,49 3,22 2,86 2,53 2,24 1,77 1,59 3,68 3,23 2,79 2,42 1,97 1,64 3,77 3,39 3 2,64 2,02 1,79 4,69 4,14 3,62 3,16 2,31 2,03 5,57 4,87 4,22 3,65 2,56 2,28 kW kW kW kW kW kW l/h kPa 1,36 1,27 1,13 1,03 0,83 0,71 250 12 1,63 1,47 1,32 1,16 0,89 0,78 330 5 1,77 1,58 1,39 1,23 0,93 0,84 400 10 1,89 1,68 1,48 1,30 1,04 0,93 370 6 2,17 1,91 1,67 1,46 1,11 0,97 460 5 2,41 2,09 1,82 1,56 1,24 1,07 550 8 2,26 2,01 1,77 1,56 1,27 1,14 470 11 2,47 2,17 1,90 1,67 1,30 1,17 550 7 2,68 2,34 2,01 1,73 1,40 1,18 630 5 3,25 2,86 2,48 2,15 1,59 1,39 650 19 3,77 3,27 2,82 2,42 1,72 1,50 800 14 4,20 3,62 3,10 2,66 1,84 1,63 960 11 kW kW kW kW kW kW l/h kPa 3,25 3,04 2,72 2,49 2,05 1,77 350 10 4,46 4,04 3,66 3,25 2,56 2,30 390 5 5,01 4,49 3,94 3,49 2,64 2,38 440 8 4,77 4,28 3,79 3,36 2,76 2,49 420 5 5,79 5,12 4,51 3,98 3,13 2,83 510 4 6,28 5,44 4,70 4,05 3,24 2,82 550 7 5,40 4,84 4,28 3,79 3,11 2,81 470 9 6,36 5,60 4,92 4,33 3,39 3,07 560 6 6,76 5,85 5,05 4,36 3,50 3,05 590 5 7,68 6,81 5,94 5,16 3,88 3,41 670 16 9,58 8,33 7,19 6,20 4,45 3,90 840 12 10,7 9,18 7,81 6,69 4,63 4,07 930 10 kW kW kW kW kW kW l/h kPa 1,98 1,86 1,66 1,52 1,25 1,08 350 11 2,71 2,46 2,22 1,97 1,55 1,39 470 5 3,04 2,72 2,39 2,11 1,60 1,44 530 8 2,91 2,61 2,31 2,04 1,68 1,51 510 5 3,52 3,11 2,74 2,41 1,90 1,72 610 5 3,80 3,30 2,84 2,45 1,96 1,70 660 7 3,29 2,94 2,60 2,30 1,89 1,71 570 10 3,86 3,40 2,98 2,62 2,05 1,85 670 6 4,09 3,54 3,05 2,63 2,09 1,80 710 5 4,69 4,15 3,62 3,14 2,36 2,07 820 17 5,83 5,06 4,37 3,76 2,69 2,36 1020 13 6,46 5,57 4,73 4,05 2,80 2,46 1130 10 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,87 130 2 1,48 1,37 1,26 1,15 0,95 0,87 130 2 - 2,12 1,92 1,74 1,57 1,30 1,20 190 4 2,12 1,92 1,74 1,57 1,30 1,20 190 4 - 2,48 2,24 2,02 1,82 1,50 1,39 220 7 2,48 2,24 2,02 1,82 1,50 1,39 220 7 - 3,48 3,13 2,78 2,46 1,92 1,72 310 13 3,48 3,13 2,78 2,46 1,92 1,72 310 13 - 46 41 38 35 30 28 0,50 1C 1/2”G F 46 41 38 35 30 28 0,70 1C 1/2”G F 47 42 39 36 31 29 0,70 1C 1/2”G F 48 44 40 37 30 29 0,70 1C 1/2”G F 48 44 40 37 30 29 1 1C 1/2”G F 49 45 41 38 31 30 1 1C 1/2”G F 48 44 40 37 31 29 1 1C 1/2”G F 48 44 40 37 31 29 1,40 1C 1/2”G F 49 45 41 38 32 30 1,40 1C 1/2”G F 51 47 43 41 33 30 1 2C 1/2”G F 51 47 43 41 33 30 1,40 2C 1/2”G F 52 48 44 42 34 31 1 2C 1/2”G F 411 495 225 12 411 495 225 12 411 495 225 14 601 495 225 15 601 495 225 15 601 495 225 17 791 495 225 18 791 495 225 18 791 495 225 20 791 495 225 20 791 495 225 20 791 495 225 22 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 66 66 66 77 77 77 93 93 93 130 130 130 A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57 0,57 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg 225 Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 520 530 540 620 630 640 720 730 740 830 840 m3/h m3/h m3/h m3/h m3/h m3/h 950 815 710 610 460 400 915 780 680 585 440 390 880 750 655 560 420 380 940 810 710 600 460 410 925 790 685 590 445 400 900 770 670 560 440 390 1360 1150 970 790 640 480 1310 1090 920 740 590 440 1260 1070 880 700 570 430 1620 1380 1165 930 720 520 1580 1340 1120 880 690 480 kW kW kW kW kW kW 4,66 4,21 3,84 3,45 2,81 2,52 5,75 5,13 4,65 4,15 3,36 3,05 6,54 5,80 5,26 4,63 3,66 3,38 5,18 4,68 4,26 3,77 3,09 2,83 6,92 6,16 5,53 4,88 3,90 3,58 7,47 6,57 5,84 5,08 4,14 3,71 6,59 5,92 5,29 4,60 3,96 3,20 8,94 7,81 6,89 5,87 4,88 3,87 9,64 8,54 7,30 6,02 5,13 4,03 10,2 9,11 8,05 6,80 5,59 4,29 11,9 10,5 9,16 7,50 6,17 4,52 kW kW kW kW kW kW l/h kPa 3,95 3,51 3,15 2,79 2,22 1,97 800 11 4,50 3,96 3,54 3,12 2,48 2,24 990 22 4,86 4,27 3,84 3,35 2,61 2,40 1120 18 4,23 3,76 3,38 2,95 2,37 2,15 890 16 5,13 4,52 4,03 3,53 2,78 2,54 1190 18 5,40 4,72 4,17 3,59 2,82 2,50 1280 14 5,61 4,94 4,33 3,68 3,11 2,45 1130 24 6,81 5,86 5,11 4,30 3,53 2,75 1530 27 7,12 6,24 5,28 4,31 3,63 2,82 1650 23 7,97 7,01 6,11 5,07 4,11 3,11 1750 24 8,82 7,71 6,65 5,38 4,37 3,07 2040 22 kW kW kW kW kW kW l/h kPa 9,92 8,86 7,98 7,11 5,70 5,09 870 10 11,2 9,88 8,85 7,83 6,18 5,58 980 19 12,3 10,7 9,56 8,34 6,47 5,91 1080 15 10,8 9,61 8,68 7,61 6,15 5,59 950 14 13,1 11,4 10,1 8,88 6,91 6,28 1150 11 13,5 11,8 10,4 8,85 7,09 6,33 1190 12 13,7 12,2 10,7 9,16 7,78 6,18 1210 21 17,4 15 13 10,8 8,88 6,84 1530 22 18 15,7 13,3 10,8 8,99 6,94 1580 19 20,3 17,9 15,6 13 10,4 7,85 1780 20 22,4 19,5 16,7 13,5 10,9 7,78 1970 19 kW kW kW kW kW kW l/h kPa 6,04 5,39 4,86 4,32 3,46 3,09 1050 10 6,81 6 5,37 4,75 3,75 3,38 1190 20 7,44 6,50 5,79 5,05 3,91 3,57 1300 16 6,67 5,93 5,33 4,73 3,77 3,36 1160 14 7,93 6,93 6,12 5,37 4,18 3,79 1380 16 8,25 7,19 6,35 5,33 4,19 3,72 1440 12 8,37 7,40 6,52 5,57 4,73 3,75 1460 22 10,6 9,10 7,89 6,55 5,37 4,13 1850 24 11 9,55 8,05 6,57 5,42 4,10 1920 21 12,4 10,9 9,47 7,85 6,31 4,75 2160 22 13,7 11,9 10,2 8,21 6,57 4,57 2380 20 kW kW kW kW kW kW l/h kPa 4,11 3,71 3,40 3,09 2,55 2,35 360 20 4,11 3,71 3,40 3,09 2,55 2,35 360 20 - 4,52 4,09 3,72 3,37 2,78 2,59 400 24 4,52 4,09 3,72 3,37 2,78 2,59 400 24 - 5,62 5,02 4,51 3,92 3,37 2,76 490 35 5,62 5,02 4,51 3,92 3,37 2,76 490 35 - 6,70 6,07 5,46 4,73 4 3,21 590 10 - 51 47 44 40 33 30 1,20 2C 1/2”G F 51 47 44 40 33 30 1,80 2C 1/2”G F 52 48 45 42 34 31 1,40 2C 1/2”G F 52 48 45 41 35 33 1,50 2C 1/2”G F 52 48 45 41 35 33 2,20 2C 1/2”G F 53 49 46 42 36 34 2,20 2C 1/2”G F 54 49 46 41 36 33 1,50 3C 1/2”G F 54 49 46 41 36 33 2,20 3C 1/2”G F 55 50 47 42 37 34 2,20 3C 1/2”G F 57 53 49 43 38 31 1,70 4C 1/2”G F 58 54 50 44 39 32 2,60 4C 1/2”G F 981 495 225 23 981 495 225 23 981 495 225 25 1171 495 225 27 1171 495 225 27 1171 495 225 29 1171 495 225 31 1171 495 225 31 1171 495 225 33 1361 495 225 38 1361 495 225 38 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 150 150 150 165 165 165 245 245 245 272 272 A 0,60 0,60 0,60 0,73 0,73 0,73 1,10 1,10 1,10 1,03 1,03 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 226 a-LIFE / DFI Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 120 130 140 220 230 240 320 330 340 420 430 440 m3/h m3/h m3/h m3/h m3/h m3/h 430 390 330 290 220 180 410 360 315 270 200 175 390 340 290 250 180 160 500 430 365 310 240 210 480 410 350 300 225 200 450 380 320 270 210 180 510 440 375 320 250 220 485 415 355 305 230 205 460 390 330 280 220 190 830 700 580 480 330 280 815 680 565 470 315 270 790 660 454 455 300 260 kW kW kW kW kW kW 1,45 1,37 1,24 1,14 0,96 0,84 1,91 1,75 1,59 1,42 1,11 0,97 2,32 2,10 1,87 1,67 1,27 1,16 2,13 1,93 1,72 1,53 1,26 1,13 2,67 2,37 2,10 1,85 1,42 1,23 3,20 2,81 2,46 2,13 1,71 1,48 2,76 2,49 2,23 1,99 1,65 1,49 3,22 2,86 2,53 2,24 1,77 1,59 3,68 3,23 2,79 2,42 1,97 1,64 3,77 3,39 3 2,64 2,02 1,79 4,69 4,14 3,62 3,16 2,31 2,03 5,57 4,87 4,22 3,65 2,56 2,28 kW kW kW kW kW kW l/h kPa 1,36 1,27 1,13 1,03 0,83 0,71 250 12 1,63 1,47 1,32 1,16 0,89 0,78 330 5 1,77 1,58 1,39 1,23 0,93 0,84 400 10 1,89 1,68 1,48 1,30 1,04 0,93 370 6 2,17 1,91 1,67 1,46 1,11 0,97 460 5 2,41 2,09 1,82 1,56 1,24 1,07 550 8 2,26 2,01 1,77 1,56 1,27 1,14 470 11 2,47 2,17 1,90 1,67 1,30 1,17 550 7 2,68 2,34 2,01 1,73 1,40 1,18 630 5 3,25 2,86 2,48 2,15 1,59 1,39 650 19 3,77 3,27 2,82 2,42 1,72 1,50 800 14 4,20 3,62 3,10 2,66 1,84 1,63 960 11 kW kW kW kW kW kW l/h kPa 3,25 3,04 2,72 2,49 2,05 1,77 350 10 4,46 4,04 3,66 3,25 2,56 2,30 390 5 5,01 4,49 3,94 3,49 2,64 2,38 440 8 4,77 4,28 3,79 3,36 2,76 2,49 420 5 5,79 5,12 4,51 3,98 3,13 2,83 510 4 6,28 5,44 4,70 4,05 3,24 2,82 550 7 5,40 4,84 4,28 3,79 3,11 2,81 470 9 6,36 5,60 4,92 4,33 3,39 3,07 560 6 6,76 5,85 5,05 4,36 3,50 3,05 590 5 7,68 6,81 5,94 5,16 3,88 3,41 670 16 9,58 8,33 7,19 6,20 4,45 3,90 840 12 10,7 9,18 7,81 6,69 4,63 4,07 930 10 kW kW kW kW kW kW l/h kPa 1,98 1,86 1,66 1,52 1,25 1,08 350 11 2,71 2,46 2,22 1,97 1,55 1,39 470 5 3,04 2,72 2,39 2,11 1,60 1,44 530 8 2,91 2,61 2,31 2,04 1,68 1,51 510 5 3,52 3,11 2,74 2,41 1,90 1,72 610 5 3,80 3,30 2,84 2,45 1,96 1,70 660 7 3,29 2,94 2,60 2,30 1,89 1,71 570 10 3,86 3,40 2,98 2,62 2,05 1,85 670 6 4,09 3,54 3,05 2,63 2,09 1,80 710 5 4,69 4,15 3,62 3,14 2,36 2,07 820 17 5,83 5,06 4,37 3,76 2,69 2,36 1020 13 6,46 5,57 4,73 4,05 2,80 2,46 1130 10 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,87 130 2 1,48 1,37 1,26 1,15 0,95 0,87 130 2 - 2,12 1,92 1,74 1,57 1,30 1,20 190 4 2,12 1,92 1,74 1,57 1,30 1,20 190 4 - 2,48 2,24 2,02 1,82 1,50 1,39 220 7 2,48 2,24 2,02 1,82 1,50 1,39 220 7 - 3,48 3,13 2,78 2,46 1,92 1,72 310 13 3,48 3,13 2,78 2,46 1,92 1,72 310 13 - 46 41 38 35 30 28 0,50 1C 1/2”G F 46 41 38 35 30 28 0,70 1C 1/2”G F 47 42 39 36 31 29 0,70 1C 1/2”G F 48 44 40 37 30 29 0,70 1C 1/2”G F 48 44 40 37 30 29 1 1C 1/2”G F 49 45 41 38 31 30 1 1C 1/2”G F 48 44 40 37 31 29 1 1C 1/2”G F 48 44 40 37 31 29 1,40 1C 1/2”G F 49 45 41 38 32 30 1,40 1C 1/2”G F 51 47 43 41 33 30 1 2C 1/2”G F 51 47 43 41 33 30 1,40 2C 1/2”G F 52 48 44 42 34 31 1 2C 1/2”G F 411 495 225 12 411 495 225 12 411 495 225 14 601 495 225 15 601 495 225 15 601 495 225 17 791 495 225 18 791 495 225 18 791 495 225 20 791 495 225 20 791 495 225 20 791 495 225 22 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 66 66 66 77 77 77 93 93 93 130 130 130 A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57 0,57 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg 227 Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 520 530 540 620 630 640 720 730 740 830 840 m3/h m3/h m3/h m3/h m3/h m3/h 950 815 710 610 460 400 915 780 680 585 440 390 880 750 655 560 420 380 940 810 710 600 460 410 925 790 685 590 445 400 900 770 670 560 440 390 1360 1150 970 790 640 480 1310 1090 920 740 590 440 1260 1070 880 700 570 430 1620 1380 1165 930 720 520 1580 1340 1120 880 690 480 kW kW kW kW kW kW 4,66 4,21 3,84 3,45 2,81 2,52 5,75 5,13 4,65 4,15 3,36 3,05 6,54 5,80 5,26 4,63 3,66 3,38 5,18 4,68 4,26 3,77 3,09 2,83 6,92 6,16 5,53 4,88 3,90 3,58 7,47 6,57 5,84 5,08 4,14 3,71 6,59 5,92 5,29 4,60 3,96 3,20 8,94 7,81 6,89 5,87 4,88 3,87 9,64 8,54 7,30 6,02 5,13 4,03 10,2 9,11 8,05 6,80 5,59 4,29 11,9 10,5 9,16 7,50 6,17 4,52 kW kW kW kW kW kW l/h kPa 3,95 3,51 3,15 2,79 2,22 1,97 800 11 4,50 3,96 3,54 3,12 2,48 2,24 990 22 4,86 4,27 3,84 3,35 2,61 2,40 1120 18 4,23 3,76 3,38 2,95 2,37 2,15 890 16 5,13 4,52 4,03 3,53 2,78 2,54 1190 18 5,40 4,72 4,17 3,59 2,82 2,50 1280 14 5,61 4,94 4,33 3,68 3,11 2,45 1130 24 6,81 5,86 5,11 4,30 3,53 2,75 1530 27 7,12 6,24 5,28 4,31 3,63 2,82 1650 23 7,97 7,01 6,11 5,07 4,11 3,11 1750 24 8,82 7,71 6,65 5,38 4,37 3,07 2040 22 kW kW kW kW kW kW l/h kPa 9,92 8,86 7,98 7,11 5,70 5,09 870 10 11,2 9,88 8,85 7,83 6,18 5,58 980 19 12,3 10,7 9,56 8,34 6,47 5,91 1080 15 10,8 9,61 8,68 7,61 6,15 5,59 950 14 13,1 11,4 10,1 8,88 6,91 6,28 1150 11 13,5 11,8 10,4 8,85 7,09 6,33 1190 12 13,7 12,2 10,7 9,16 7,78 6,18 1210 21 17,4 15 13 10,8 8,88 6,84 1530 22 18 15,7 13,3 10,8 8,99 6,94 1580 19 20,3 17,9 15,6 13 10,4 7,85 1780 20 22,4 19,5 16,7 13,5 10,9 7,78 1970 19 kW kW kW kW kW kW l/h kPa 6,04 5,39 4,86 4,32 3,46 3,09 1050 10 6,81 6 5,37 4,75 3,75 3,38 1190 20 7,44 6,50 5,79 5,05 3,91 3,57 1300 16 6,67 5,93 5,33 4,73 3,77 3,36 1160 14 7,93 6,93 6,12 5,37 4,18 3,79 1380 16 8,25 7,19 6,35 5,33 4,19 3,72 1440 12 8,37 7,40 6,52 5,57 4,73 3,75 1460 22 10,6 9,10 7,89 6,55 5,37 4,13 1850 24 11 9,55 8,05 6,57 5,42 4,10 1920 21 12,4 10,9 9,47 7,85 6,31 4,75 2160 22 13,7 11,9 10,2 8,21 6,57 4,57 2380 20 kW kW kW kW kW kW l/h kPa 4,11 3,71 3,40 3,09 2,55 2,35 360 20 4,11 3,71 3,40 3,09 2,55 2,35 360 20 - 4,52 4,09 3,72 3,37 2,78 2,59 400 24 4,52 4,09 3,72 3,37 2,78 2,59 400 24 - 5,62 5,02 4,51 3,92 3,37 2,76 490 35 5,62 5,02 4,51 3,92 3,37 2,76 490 35 - 6,70 6,07 5,46 4,73 4 3,21 590 10 - 51 47 44 40 33 30 1,20 2C 1/2”G F 51 47 44 40 33 30 1,80 2C 1/2”G F 52 48 45 42 34 31 1,40 2C 1/2”G F 52 48 45 41 35 33 1,50 2C 1/2”G F 52 48 45 41 35 33 2,20 2C 1/2”G F 53 49 46 42 36 34 2,20 2C 1/2”G F 54 49 46 41 36 33 1,50 3C 1/2”G F 54 49 46 41 36 33 2,20 3C 1/2”G F 55 50 47 42 37 34 2,20 3C 1/2”G F 57 53 49 43 38 31 1,70 4C 1/2”G F 58 54 50 44 39 32 2,60 4C 1/2”G F 981 495 225 23 981 495 225 23 981 495 225 25 1171 495 225 27 1171 495 225 27 1171 495 225 29 1171 495 225 31 1171 495 225 31 1171 495 225 33 1361 495 225 38 1361 495 225 38 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 150 150 150 165 165 165 245 245 245 272 272 A 0,60 0,60 0,60 0,73 0,73 0,73 1,10 1,10 1,10 1,03 1,03 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 228 Dimension H H L P L P 229 Hydronic terminals a-LIFE HP 230÷840 Versions DFI DLI built-in version, front air intake built-in version, bottom air intake Features Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil); High pressure centrifugal fan unit for ducted system; 6-speed autotransformer; Air filter on all models; Structure in hot galvanised steel for maximum resistance to rust; Main accessories High head fan-coil for professional application built-in version 2,83 - 10,9 kW Unit Description a-LIFE HP are professional high-head fan coils by Climaveneta. The enhanced motor and the built-in version make these units ideal for ducted systems in tertiary and commercial sectors. Commands NSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW wall mounted Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/ winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW wall mounted Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. 230 UÊHot water coil kit 1 row and 2 rows UÊKit RS485 - interface for Building Management System UÊKit control board to manage 0-10V or 3 points modulating valve unit UÊMain coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-way UÊAdditional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way UÊStraight and angular (90°) plenum kits for air inlet UÊStraight and angular (90°) plenum kits for air outlet UÊPlenum kit with round air ducts for plenum kit UÊElectric heaters CONTROLLER DUCT FAN COIL 4 PIPES CENTRIFUGAL 2 PIPES a-LIFE HP / DLI Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Effective static pressure Speed 1 - Max Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 230 240 430 440 530 540 730 740 830 840 m3/h m3/h m3/h m3/h m3/h m3/h 520 490 460 415 320 275 520 490 460 415 320 275 600 540 470 405 290 250 600 540 470 405 290 250 930 800 670 520 380 280 930 800 670 520 380 280 960 890 810 695 540 380 960 890 810 695 540 380 1330 1260 1130 940 720 520 1330 1260 1130 940 720 520 Pa 40 40 40 40 40 40 40 40 40 40 kW kW kW kW kW kW 2,83 2,71 2,59 2,39 1,95 1,72 3,57 3,41 3,25 3 2,46 2,17 4,04 3,74 3,37 3,01 2,31 2,04 4,69 4,35 3,91 3,46 2,59 2,29 5,58 5,02 4,41 3,64 2,87 2,25 6,54 5,90 5,15 4,19 3,26 2,50 7,36 6,97 6,47 5,77 4,67 3,54 8,15 7,66 7,09 6,23 5,11 3,75 9,95 9,56 8,83 7,68 6,27 4,81 10,9 10,5 9,60 8,25 6,63 5,06 kW kW kW kW kW kW l/h kPa 2,32 2,21 2,10 1,93 1,54 1,35 480 5 2,72 2,59 2,45 2,24 1,82 1,59 610 10 3,13 2,87 2,56 2,26 1,70 1,49 690 11 3,45 3,19 2,84 2,50 1,85 1,63 810 9 4,39 3,90 3,37 2,73 2,11 1,63 960 23 4,90 4,38 3,78 3,04 2,32 1,76 1120 17 5,45 5,14 4,74 4,20 3,36 2,43 1260 20 5,90 5,52 5,09 4,44 3,46 2,43 1400 16 7,53 7,21 6,60 5,66 4,55 3,33 1710 21 7,94 7,62 6,94 5,91 4,69 3,33 1870 19 kW kW kW kW kW kW l/h kPa 6,16 5,88 5,60 5,17 4,19 3,70 540 4 7,07 6,73 6,39 5,86 4,70 4,11 620 9 7,85 7,26 6,54 5,82 4,43 3,90 770 10 8,72 7,98 7,08 6,22 4,63 4,04 770 8 11,4 10,1 8,75 7,11 5,46 4,19 1000 20 12,8 11,3 9,74 7,82 5,91 4,48 1130 16 13,8 12,9 11,9 10,4 8,37 6,11 1210 18 14,3 13,4 12,3 10,8 8,56 6,16 1260 13 18,6 17,8 16,3 14 11,1 8,39 1630 18 19,4 18,5 16,8 14,3 11,3 8,38 1700 16 kW kW kW kW kW kW l/h kPa 3,75 3,58 3,41 3,14 2,55 2,25 650 4 4,29 4,08 3,87 3,55 2,84 2,49 750 10 4,76 4,38 3,91 3,46 2,61 2,29 830 10 5,34 4,88 4,33 3,80 2,76 2,37 930 9 6,90 6,12 5,31 4,31 3,30 2,53 1200 21 7,86 6,93 5,96 4,78 3,61 2,67 1370 17 8,58 8,04 7,42 6,50 5,14 3,62 1500 18 9,14 8,48 7,72 6,62 5,14 3,62 1600 15 11,3 10,8 9,86 8,46 6,74 4,95 1970 19 12 11,4 10,4 8,83 6,86 4,95 2090 18 kW kW kW kW kW kW l/h kPa 2,23 2,15 2,07 1,94 1,64 1,48 200 4 - 3,34 3,13 2,86 2,59 2,07 1,87 290 13 - 4,42 4,02 3,59 3,04 2,46 1,99 390 20 - 5,45 5,19 4,88 4,42 3,74 2,94 480 35 - 7,68 7,43 6,93 6,16 5,17 4,15 670 10 - 48 44 40 37 31 30 1 1C 1/2” G F 140 0,64 230-1-50 49 45 41 38 32 31 1,30 1C 1/2” G F 140 0,64 230-1-50 51 47 44 42 33 31 1,40 2C 1/2” G F 120 0,58 230-1-50 52 48 45 43 34 32 19 2C 1/2” G F 120 0,58 230-1-50 51 47 44 40 33 30 1,80 2C 1/2” G F 210 0,95 230-1-50 52 48 45 41 34 31 2,40 2C 1/2” G F 210 0,95 230-1-50 54 49 45 42 36 34 2,20 2C 1/2” G F 240 1,10 230-1-50 55 50 46 43 37 35 2,90 2C 1/2” G F 240 1,10 230-1-50 57 53 49 43 38 31 2,60 3C 1/2” G F 270 1,20 230-1-50 58 54 50 44 39 32 3,50 3C 1/2” G F 270 1,20 230-1-50 601 495 225 18 601 495 225 18 791 495 225 21 791 495 225 21 981 495 225 27 981 495 225 27 1171 495 225 29 1171 495 225 29 1361 495 225 40 1361 495 225 40 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch W A V-Ph~Hz (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 231 a-LIFE HP / DFI Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Effective static pressure Speed 1 - Max Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 230 240 430 440 530 540 730 740 830 840 m3/h m3/h m3/h m3/h m3/h m3/h 520 490 460 415 320 275 520 490 460 415 320 275 600 540 470 405 290 250 600 540 470 405 290 250 930 800 670 520 380 280 930 800 670 520 380 280 960 890 810 695 540 380 960 890 810 695 540 380 1330 1260 1130 940 720 520 1330 1260 1130 940 720 520 Pa 40 40 40 40 40 40 40 40 40 40 kW kW kW kW kW kW 2,83 2,71 2,59 2,39 1,95 1,72 3,57 3,41 3,25 3 2,46 2,17 4,04 3,74 3,37 3,01 2,31 2,04 4,69 4,35 3,91 3,46 2,59 2,29 5,58 5,02 4,41 3,64 2,87 2,25 6,54 5,90 5,15 4,19 3,26 2,50 7,36 6,97 6,47 5,77 4,67 3,54 8,15 7,66 7,09 6,23 5,11 3,75 9,95 9,56 8,83 7,68 6,27 4,81 10,9 10,5 9,60 8,25 6,63 5,06 kW kW kW kW kW kW l/h kPa 2,32 2,21 2,10 1,93 1,54 1,35 480 5 2,72 2,59 2,45 2,24 1,82 1,59 610 10 3,13 2,87 2,56 2,26 1,70 1,49 690 11 3,45 3,19 2,84 2,50 1,85 1,63 810 9 4,39 3,90 3,37 2,73 2,11 1,63 960 23 4,90 4,38 3,78 3,04 2,32 1,76 1120 17 5,45 5,14 4,74 4,20 3,36 2,43 1260 20 5,90 5,52 5,09 4,44 3,46 2,43 1400 16 7,53 7,21 6,60 5,66 4,55 3,33 1710 21 7,94 7,62 6,94 5,91 4,69 3,33 1870 19 kW kW kW kW kW kW l/h kPa 6,16 5,88 5,60 5,17 4,19 3,70 540 4 7,07 6,73 6,39 5,86 4,70 4,11 620 9 7,85 7,26 6,54 5,82 4,43 3,90 770 10 8,72 7,98 7,08 6,22 4,63 4,04 770 8 11,4 10,1 8,75 7,11 5,46 4,19 1000 20 12,8 11,3 9,74 7,82 5,91 4,48 1130 16 13,8 12,9 11,9 10,4 8,37 6,11 1210 18 14,3 13,4 12,3 10,8 8,56 6,16 1260 13 18,6 17,8 16,3 14 11,1 8,39 1630 18 19,4 18,5 16,8 14,3 11,3 8,38 1700 16 kW kW kW kW kW kW l/h kPa 3,75 3,58 3,41 3,14 2,55 2,25 650 4 4,29 4,08 3,87 3,55 2,84 2,49 750 10 4,76 4,38 3,91 3,46 2,61 2,29 830 10 5,34 4,88 4,33 3,80 2,76 2,37 930 9 6,90 6,12 5,31 4,31 3,30 2,53 1200 21 7,86 6,93 5,96 4,78 3,61 2,67 1370 17 8,58 8,04 7,42 6,50 5,14 3,62 1500 18 9,14 8,48 7,72 6,62 5,14 3,62 1600 15 11,3 10,8 9,86 8,46 6,74 4,95 1970 19 12 11,4 10,4 8,83 6,86 4,95 2090 18 kW kW kW kW kW kW l/h kPa 2,23 2,15 2,07 1,94 1,64 1,48 200 4 - 3,34 3,13 2,86 2,59 2,07 1,87 290 13 - 4,42 4,02 3,59 3,04 2,46 1,99 390 20 - 5,45 5,19 4,88 4,42 3,74 2,94 480 35 - 7,68 7,43 6,93 6,16 5,17 4,15 670 10 - 48 44 40 37 31 30 1 1C 1/2” G F 140 0,64 230-1-50 49 45 41 38 32 31 1,30 1C 1/2” G F 140 0,64 230-1-50 51 47 44 42 33 31 1,40 2C 1/2” G F 120 0,58 230-1-50 52 48 45 43 34 32 19 2C 1/2” G F 120 0,58 230-1-50 51 47 44 40 33 30 1,80 2C 1/2” G F 210 0,95 230-1-50 52 48 45 41 34 31 2,40 2C 1/2” G F 210 0,95 230-1-50 54 49 45 42 36 34 2,20 2C 1/2” G F 240 1,10 230-1-50 55 50 46 43 37 35 2,90 2C 1/2” G F 240 1,10 230-1-50 57 53 49 43 38 31 2,60 3C 1/2” G F 270 1,20 230-1-50 58 54 50 44 39 32 3,50 3C 1/2” G F 270 1,20 230-1-50 601 495 225 18 601 495 225 18 791 495 225 21 791 495 225 21 981 495 225 27 981 495 225 27 1171 495 225 29 1171 495 225 29 1361 495 225 40 1361 495 225 40 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch W A V-Ph~Hz (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 232 Dimension H L P 233 Hydronic terminals i-LIFE 130÷640 Versions DFI DFU DLI DLU built-in version, front air intake version with cabinet, front air intake built-in version, bottom air intake version with cabinet, bottom air intake Features Brushless motor with permanent magnets electronic switches; Modulating centrifugal fan with fine regulation of the air flow; Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil); Cabinet in galvanised steel with prevarnished finish for maximum resistance to rust; Air filter on all models; Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40); Main accessories Fan-coil with high efficiency brushless motor, continuous air flow modulation, universal installation 1,91 - 7,47 kW Unit Description NEW i-LIFE fan-coil is powered by modulating speed centrifugal fan. This new generation of fan-coil guarantees air flow regulation from 0% to 100% and energy consumption is reduced by more than 50% respect traditional unit. Furthermore new commands are available to manage all functions offered by this range of terminal units. Commands EK plug-in control /EKW wall mounted control User interface for selection of functioning mode (OFF/summer/winter/AUTO), fan speed (Max/Med/Min/AUTO), temperature set. Control of main coil valve unit (summer/winter - 2 pipes installation) and additional coil (winter - 4 pipes installation). Management of traditional ON/OFF valve unit or modulating valve unit 0-10V or 3 points (supply 230 VAC or 24V) . Air and water temperature probe. Multifunction digital input configurable by user. Configuration dip switch. Modbus protocol for installation in Building Management System (e.g. Idrorelax system by Climaveneta). Installation and management of MasterSlave system up to 8 LIFE fan coil units. Easy control installation thanks to 2 wires connection. iK control with LCD screen Interface with LCD screen with user-friendly icons. Control kit for universal installation: wall-mounted as well as plug-in. Selection of functioning mode (OFF/summer/winter/AUTO), fan speed (Max/Med/Min/AUTO), temperature set. Control iK could function manually or with weekly timer regulation configurable by the customer. Control of main coil valve unit (summer/ winter - 2 pipes) and additional coil (winter - 4 pipes). Management of traditional ON/OFF valve unit or modulating valve unit 0-10V or 3 points (supply 230 VAC or 24V) . Parameters configurable directly by user. Modbus protocol for installation in Building Management System (e.g. Idrorelax system by Climaveneta). Installation and management of Master-Slave system up to 8 LIFE fan coil units. Easy control installation thanks to 2 wires connection. 234 UÊHot water coil kit 1 row and 2 rows UÊKit RS485 - interface for Building Management System UÊKit control board to manage 0-10V or 3 points modulating valve unit UÊMain coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-way UÊAdditional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way UÊKit LIFE BOX CONTROLLER CENTRIFUGAL FAN COIL 4 PIPES 2 PIPES i-LIFE / DLU Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Min absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P Weight 130 140 230 240 330 340 430 440 530 540 630 640 m3/h m3/h m3/h m3/h m3/h m3/h 410 360 315 270 200 105 390 340 290 250 180 95 480 410 350 300 225 120 450 380 320 270 210 110 485 415 355 305 230 130 460 390 330 280 220 120 815 680 565 470 315 200 790 660 545 455 300 190 915 780 680 585 440 310 880 750 655 560 420 295 925 790 685 590 445 320 900 770 670 560 440 305 kW kW kW kW kW kW 1,91 1,75 1,59 1,42 1,11 0,70 2,32 2,10 1,87 1,67 1,27 0,75 2,67 2,37 2,10 1,85 1,42 0,88 3,20 2,81 2,46 2,13 1,71 1,00 3,22 2,86 2,53 2,24 1,77 1,06 3,68 3,23 2,79 2,42 1,97 1,16 4,69 4,14 3,62 3,16 2,31 1,56 5,57 4,87 4,22 3,65 2,56 1,64 5,75 5,13 4,65 4,15 3,36 2,53 6,54 5,80 5,26 4,63 3,66 2,72 6,92 6,16 5,53 4,88 3,90 2,95 7,47 6,57 5,84 5,08 4,14 2,95 kW kW kW kW kW kW l/h kPa 1,63 1,47 1,32 1,16 0,89 0,53 330 5 1,77 1,58 1,39 1,23 0,93 0,54 400 10 2,17 1,91 1,67 1,46 1,11 0,66 460 5 2,41 2,09 1,82 1,56 1,24 0,70 550 8 2,47 2,17 1,90 1,67 1,30 0,77 550 7 2,68 2,34 2,01 1,73 1,40 0,77 630 5 3,77 3,27 2,82 2,42 1,72 1,15 800 14 4,20 3,62 3,10 2,66 1,84 1,18 960 11 4,50 3,96 3,54 3,12 2,48 1,84 990 22 4,86 4,27 3,84 3,35 2,61 1,91 1120 18 5,13 4,52 4,03 3,53 2,78 2,07 1190 18 5,40 4,72 4,17 3,59 2,82 1,95 1280 14 kW kW kW kW kW kW l/h kPa 4,46 4,04 3,66 3,25 2,56 1,50 390 5 5,01 4,49 3,94 3,49 2,64 1,49 440 8 5,79 5,12 4,51 3,98 3,13 1,81 510 4 6,28 5,44 4,70 4,05 3,24 1,78 550 7 6,36 5,60 4,92 4,33 3,39 2,04 560 6 6,76 5,85 5,05 4,36 3,50 1,94 590 5 9,58 8,33 7,19 6,20 4,45 3,00 840 12 10,7 9,18 7,81 6,69 4,63 3,05 930 10 11,2 9,88 8,85 7,83 6,18 4,58 980 19 12,3 10,7 9,56 8,34 6,47 4,70 1080 15 13,1 11,4 10,1 8,88 6,91 5,12 1150 11 13,5 11,8 10,4 8,85 7,09 4,44 1190 12 kW kW kW kW kW kW l/h kPa 2,71 2,46 2,22 1,97 1,55 0,91 470 5 3,04 2,72 2,39 2,11 1,60 0,90 530 8 3,52 3,11 2,74 2,41 1,90 1,10 610 5 3,80 3,30 2,84 2,45 1,96 1,05 660 7 3,86 3,40 2,98 2,62 2,05 1,23 670 6 4,09 3,54 3,05 2,63 2,09 1,14 710 5 5,83 5,06 4,37 3,76 2,69 1,82 1020 13 6,46 5,57 4,73 4,05 2,80 1,80 1130 10 6,81 6 5,37 4,75 3,75 2,77 1190 20 7,44 6,50 5,79 5,05 3,91 2,81 1300 16 7,93 6,93 6,12 5,37 4,18 3,05 1380 16 8,25 7,19 6,35 5,33 4,19 2,90 1440 12 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,62 130 2 - 2,12 1,92 1,74 1,57 1,30 0,84 190 4 - 2,48 2,24 2,02 1,82 1,50 1,00 220 7 - 3,48 3,13 2,78 2,46 1,92 1,36 310 13 - 4,11 3,71 3,40 3,09 2,55 2,01 360 20 - 4,52 4,09 3,72 3,37 2,78 2,21 400 24 - 46 41 38 35 30 22 0,70 1C 1/2”G F 47 42 39 36 31 22 0,70 1C 1/2”G F 48 44 40 37 30 23 1 1C 1/2”G F 49 45 41 38 31 23 1 1C 1/2”G F 48 44 40 37 31 24 1,40 1C 1/2”G F 49 45 41 38 32 24 1,40 1C 1/2”G F 51 47 43 41 33 25 1,40 2C 1/2”G F 52 48 44 42 34 25 1 2C 1/2”G F 51 47 44 40 33 26 1,80 2C 1/2”G F 52 48 45 42 34 26 1,40 2C 1/2”G F 52 48 45 41 35 26 2,20 2C 1/2”G F 53 49 46 42 36 26 2,20 2C 1/2”G F 732 541 233 18 732 541 233 18 922 541 233 22 922 541 233 22 1112 541 233 26 1112 541 233 26 1112 541 233 28 1112 541 233 28 1302 541 233 32 1302 541 233 32 1492 541 233 38 1492 541 233 38 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 33 33 34 34 37 37 59 59 72 72 74 74 W 4 4 4 4 4 4 7 7 7 7 7 7 0,49 0,49 0,57 0,57 0,58 0,58 A 0,29 0,29 0,29 0,29 0,31 0,31 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 235 i-LIFE / DFU Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Min absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P Weight 130 140 230 240 330 340 430 440 530 540 630 640 m3/h m3/h m3/h m3/h m3/h m3/h 410 360 315 270 200 105 390 340 290 250 180 95 480 410 350 300 225 120 450 380 320 270 210 110 485 415 355 305 230 130 460 390 330 280 220 120 815 680 565 470 315 200 790 660 545 455 300 190 915 780 680 585 440 310 880 750 655 560 420 295 925 790 685 590 445 320 900 770 670 560 440 305 kW kW kW kW kW kW 1,91 1,75 1,59 1,42 1,11 0,70 2,32 2,10 1,87 1,67 1,27 0,75 2,67 2,37 2,10 1,85 1,42 0,88 3,20 2,81 2,46 2,13 1,71 1,00 3,22 2,86 2,53 2,24 1,77 1,06 3,68 3,23 2,79 2,42 1,97 1,16 4,69 4,14 3,62 3,16 2,31 1,56 5,57 4,87 4,22 3,65 2,56 1,64 5,75 5,13 4,65 4,15 3,36 2,53 6,54 5,80 5,26 4,63 3,66 2,72 6,92 6,16 5,53 4,88 3,90 2,95 7,47 6,57 5,84 5,08 4,14 2,95 kW kW kW kW kW kW l/h kPa 1,63 1,47 1,32 1,16 0,89 0,53 330 5 1,77 1,58 1,39 1,23 0,93 0,54 400 10 2,17 1,91 1,67 1,46 1,11 0,66 460 5 2,41 2,09 1,82 1,56 1,24 0,70 550 8 2,47 2,17 1,90 1,67 1,30 0,77 550 7 2,68 2,34 2,01 1,73 1,40 0,77 630 5 3,77 3,27 2,82 2,42 1,72 1,15 800 14 4,20 3,62 3,10 2,66 1,84 1,18 960 11 4,50 3,96 3,54 3,12 2,48 1,84 990 22 4,86 4,27 3,84 3,35 2,61 1,91 1120 18 5,13 4,52 4,03 3,53 2,78 2,07 1190 18 5,40 4,72 4,17 3,59 2,82 1,95 1280 14 kW kW kW kW kW kW l/h kPa 4,46 4,04 3,66 3,25 2,56 1,50 390 5 5,01 4,49 3,94 3,49 2,64 1,49 440 8 5,79 5,12 4,51 3,98 3,13 1,81 510 4 6,28 5,44 4,70 4,05 3,24 1,78 550 7 6,36 5,60 4,92 4,33 3,39 2,04 560 6 6,76 5,85 5,05 4,36 3,50 1,94 590 5 9,58 8,33 7,19 6,20 4,45 3,00 840 12 10,7 9,18 7,81 6,69 4,63 3,05 930 10 11,2 9,88 8,85 7,83 6,18 4,58 980 19 12,3 10,7 9,56 8,34 6,47 4,70 1080 15 13,1 11,4 10,1 8,88 6,91 5,12 1150 11 13,5 11,8 10,4 8,85 7,09 4,44 1190 12 kW kW kW kW kW kW l/h kPa 2,71 2,46 2,22 1,97 1,55 0,91 470 5 3,04 2,72 2,39 2,11 1,60 0,90 530 8 3,52 3,11 2,74 2,41 1,90 1,10 610 5 3,80 3,30 2,84 2,45 1,96 1,05 660 7 3,86 3,40 2,98 2,62 2,05 1,23 670 6 4,09 3,54 3,05 2,63 2,09 1,14 710 5 5,83 5,06 4,37 3,76 2,69 1,82 1020 13 6,46 5,57 4,73 4,05 2,80 1,80 1130 10 6,81 6 5,37 4,75 3,75 2,77 1190 20 7,44 6,50 5,79 5,05 3,91 2,81 1300 16 7,93 6,93 6,12 5,37 4,18 3,05 1380 16 8,25 7,19 6,35 5,33 4,19 2,90 1440 12 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,62 130 2 - 2,12 1,92 1,74 1,57 1,30 0,84 190 4 - 2,48 2,24 2,02 1,82 1,50 1,00 220 7 - 3,48 3,13 2,78 2,46 1,92 1,36 310 13 - 4,11 3,71 3,40 3,09 2,55 2,01 360 20 - 4,52 4,09 3,72 3,37 2,78 2,21 400 24 - 46 41 38 35 30 22 0,70 1C 1/2”G F 47 42 39 36 31 22 0,70 1C 1/2”G F 48 44 40 37 30 23 1 1C 1/2”G F 49 45 41 38 31 23 1 1C 1/2”G F 48 44 40 37 31 24 1,40 1C 1/2”G F 49 45 41 38 32 24 1,40 1C 1/2”G F 51 47 43 41 33 25 1,40 2C 1/2”G F 52 48 44 42 34 25 1 2C 1/2”G F 51 47 44 40 33 26 1,80 2C 1/2”G F 52 48 45 42 34 26 1,40 2C 1/2”G F 52 48 45 41 35 26 2,20 2C 1/2”G F 53 49 46 42 36 26 2,20 2C 1/2”G F 732 541 245 18 732 541 245 18 922 541 245 22 922 541 245 22 1112 541 245 26 1112 541 245 26 1112 541 245 28 1112 541 245 28 1302 541 245 32 1302 541 245 32 1492 541 245 38 1492 541 245 38 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 33 33 34 34 37 37 59 59 72 72 74 74 W 4 4 4 4 4 4 7 7 7 7 7 7 0,49 0,49 0,57 0,57 0,58 0,58 A 0,29 0,29 0,29 0,29 0,31 0,31 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 236 i-LIFE / DLI Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Min absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P Weight 130 140 230 240 330 340 430 440 530 540 630 640 m3/h m3/h m3/h m3/h m3/h m3/h 410 360 315 270 200 105 390 340 290 250 180 95 480 410 350 300 225 120 450 380 320 270 210 110 485 415 355 305 230 130 460 390 330 280 220 120 815 680 565 470 315 200 790 660 545 455 300 190 915 780 680 585 440 310 880 750 655 560 420 295 925 790 685 590 445 320 900 770 670 560 440 305 kW kW kW kW kW kW 1,91 1,75 1,59 1,42 1,11 0,70 2,32 2,10 1,87 1,67 1,27 0,75 2,67 2,37 2,10 1,85 1,42 0,88 3,20 2,81 2,46 2,13 1,71 1,00 3,22 2,86 2,53 2,24 1,77 1,06 3,68 3,23 2,79 2,42 1,97 1,16 4,69 4,14 3,62 3,16 2,31 1,56 5,57 4,87 4,22 3,65 2,56 1,64 5,75 5,13 4,65 4,15 3,36 2,53 6,54 5,80 5,26 4,63 3,66 2,72 6,92 6,16 5,53 4,88 3,90 2,95 7,47 6,57 5,84 5,08 4,14 2,95 kW kW kW kW kW kW l/h kPa 1,63 1,47 1,32 1,16 0,89 0,53 330 5 1,77 1,58 1,39 1,23 0,93 0,54 400 10 2,17 1,91 1,67 1,46 1,11 0,66 460 5 2,41 2,09 1,82 1,56 1,24 0,70 550 8 2,47 2,17 1,90 1,67 1,30 0,77 550 7 2,68 2,34 2,01 1,73 1,40 0,77 630 5 3,77 3,27 2,82 2,42 1,72 1,15 800 14 4,20 3,62 3,10 2,66 1,84 1,18 960 11 4,50 3,96 3,54 3,12 2,48 1,84 990 22 4,86 4,27 3,84 3,35 2,61 1,91 1120 18 5,13 4,52 4,03 3,53 2,78 2,07 1190 18 5,40 4,72 4,17 3,59 2,82 1,95 1280 14 kW kW kW kW kW kW l/h kPa 4,46 4,04 3,66 3,25 2,56 1,50 390 5 5,01 4,49 3,94 3,49 2,64 1,49 440 8 5,79 5,12 4,51 3,98 3,13 1,81 510 4 6,28 5,44 4,70 4,05 3,24 1,78 550 7 6,36 5,60 4,92 4,33 3,39 2,04 560 6 6,76 5,85 5,05 4,36 3,50 1,94 590 5 9,58 8,33 7,19 6,20 4,45 3,00 840 12 10,7 9,18 7,81 6,69 4,63 3,05 930 10 11,2 9,88 8,85 7,83 6,18 4,58 980 19 12,3 10,7 9,56 8,34 6,47 4,70 1080 15 13,1 11,4 10,1 8,88 6,91 5,12 1150 11 13,5 11,8 10,4 8,85 7,09 4,44 1190 12 kW kW kW kW kW kW l/h kPa 2,71 2,46 2,22 1,97 1,55 0,91 470 5 3,04 2,72 2,39 2,11 1,60 0,90 530 8 3,52 3,11 2,74 2,41 1,90 1,10 610 5 3,80 3,30 2,84 2,45 1,96 1,05 660 7 3,86 3,40 2,98 2,62 2,05 1,23 670 6 4,09 3,54 3,05 2,63 2,09 1,14 710 5 5,83 5,06 4,37 3,76 2,69 1,82 1020 13 6,46 5,57 4,73 4,05 2,80 1,80 1130 10 6,81 6 5,37 4,75 3,75 2,77 1190 20 7,44 6,50 5,79 5,05 3,91 2,81 1300 16 7,93 6,93 6,12 5,37 4,18 3,05 1380 16 8,25 7,19 6,35 5,33 4,19 2,90 1440 12 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,62 130 2 - 2,12 1,92 1,74 1,57 1,30 0,84 190 4 - 2,48 2,24 2,02 1,82 1,50 1,00 220 7 - 3,48 3,13 2,78 2,46 1,92 1,36 310 13 - 4,11 3,71 3,40 3,09 2,55 2,01 360 20 - 4,52 4,09 3,72 3,37 2,78 2,21 400 24 - 46 41 38 35 30 22 0,70 1C 1/2”G F 47 42 39 36 31 22 0,70 1C 1/2”G F 48 44 40 37 30 23 1 1C 1/2”G F 49 45 41 38 31 23 1 1C 1/2”G F 48 44 40 37 31 24 1,40 1C 1/2”G F 49 45 41 38 32 24 1,40 1C 1/2”G F 51 47 43 41 33 25 1,40 2C 1/2”G F 52 48 44 42 34 25 1 2C 1/2”G F 51 47 44 40 33 26 1,80 2C 1/2”G F 52 48 45 42 34 26 1,40 2C 1/2”G F 52 48 45 41 35 26 2,20 2C 1/2”G F 53 49 46 42 36 26 2,20 2C 1/2”G F 411 495 225 12 411 495 225 14 601 495 225 15 601 495 225 17 791 495 225 18 791 495 225 20 791 495 225 20 791 495 225 22 981 495 225 23 981 495 225 25 1171 495 225 27 1171 495 225 29 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 33 33 34 34 37 37 59 59 72 72 74 74 W 4 4 4 4 4 4 7 7 7 7 7 7 0,49 0,49 0,57 0,57 0,58 0,58 A 0,29 0,29 0,29 0,29 0,31 0,31 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 237 i-LIFE / DFI Models Air flow rate Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Total output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Sensible output cooling capacity (1) Speed 1 (1) Speed 2 (1) Speed 3 (1) Speed 4 (1) Speed 5 (1) Speed 6 (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Speed 1 (3) Speed 2 (3) Speed 3 (3) Speed 4 (3) Speed 5 (3) Speed 6 (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Speed 1 (2) Speed 2 (2) Speed 3 (2) Speed 4 (2) Speed 5 (2) Speed 6 (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Speed 1 (4) Speed 2 (4) Speed 3 (4) Speed 4 (4) Speed 5 (4) Speed 6 (4) Water content Fan Water IN connection Water OUT connection Max absorbed power Min absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P Weight 130 140 230 240 330 340 430 440 530 540 630 640 m3/h m3/h m3/h m3/h m3/h m3/h 410 360 315 270 200 105 390 340 290 250 180 95 480 410 350 300 225 120 450 380 320 270 210 110 485 415 355 305 230 130 460 390 330 280 220 120 815 680 565 470 315 200 790 660 545 455 300 190 915 780 680 585 440 310 880 750 655 560 420 295 925 790 685 590 445 320 900 770 670 560 440 305 kW kW kW kW kW kW 1,91 1,75 1,59 1,42 1,11 0,70 2,32 2,10 1,87 1,67 1,27 0,75 2,67 2,37 2,10 1,85 1,42 0,88 3,20 2,81 2,46 2,13 1,71 1,00 3,22 2,86 2,53 2,24 1,77 1,06 3,68 3,23 2,79 2,42 1,97 1,16 4,69 4,14 3,62 3,16 2,31 1,56 5,57 4,87 4,22 3,65 2,56 1,64 5,75 5,13 4,65 4,15 3,36 2,53 6,54 5,80 5,26 4,63 3,66 2,72 6,92 6,16 5,53 4,88 3,90 2,95 7,47 6,57 5,84 5,08 4,14 2,95 kW kW kW kW kW kW l/h kPa 1,63 1,47 1,32 1,16 0,89 0,53 330 5 1,77 1,58 1,39 1,23 0,93 0,54 400 10 2,17 1,91 1,67 1,46 1,11 0,66 460 5 2,41 2,09 1,82 1,56 1,24 0,70 550 8 2,47 2,17 1,90 1,67 1,30 0,77 550 7 2,68 2,34 2,01 1,73 1,40 0,77 630 5 3,77 3,27 2,82 2,42 1,72 1,15 800 14 4,20 3,62 3,10 2,66 1,84 1,18 960 11 4,50 3,96 3,54 3,12 2,48 1,84 990 22 4,86 4,27 3,84 3,35 2,61 1,91 1120 18 5,13 4,52 4,03 3,53 2,78 2,07 1190 18 5,40 4,72 4,17 3,59 2,82 1,95 1280 14 kW kW kW kW kW kW l/h kPa 4,46 4,04 3,66 3,25 2,56 1,50 390 5 5,01 4,49 3,94 3,49 2,64 1,49 440 8 5,79 5,12 4,51 3,98 3,13 1,81 510 4 6,28 5,44 4,70 4,05 3,24 1,78 550 7 6,36 5,60 4,92 4,33 3,39 2,04 560 6 6,76 5,85 5,05 4,36 3,50 1,94 590 5 9,58 8,33 7,19 6,20 4,45 3,00 840 12 10,7 9,18 7,81 6,69 4,63 3,05 930 10 11,2 9,88 8,85 7,83 6,18 4,58 980 19 12,3 10,7 9,56 8,34 6,47 4,70 1080 15 13,1 11,4 10,1 8,88 6,91 5,12 1150 11 13,5 11,8 10,4 8,85 7,09 4,44 1190 12 kW kW kW kW kW kW l/h kPa 2,71 2,46 2,22 1,97 1,55 0,91 470 5 3,04 2,72 2,39 2,11 1,60 0,90 530 8 3,52 3,11 2,74 2,41 1,90 1,10 610 5 3,80 3,30 2,84 2,45 1,96 1,05 660 7 3,86 3,40 2,98 2,62 2,05 1,23 670 6 4,09 3,54 3,05 2,63 2,09 1,14 710 5 5,83 5,06 4,37 3,76 2,69 1,82 1020 13 6,46 5,57 4,73 4,05 2,80 1,80 1130 10 6,81 6 5,37 4,75 3,75 2,77 1190 20 7,44 6,50 5,79 5,05 3,91 2,81 1300 16 7,93 6,93 6,12 5,37 4,18 3,05 1380 16 8,25 7,19 6,35 5,33 4,19 2,90 1440 12 kW kW kW kW kW kW l/h kPa 1,48 1,37 1,26 1,15 0,95 0,62 130 2 - 2,12 1,92 1,74 1,57 1,30 0,84 190 4 - 2,48 2,24 2,02 1,82 1,50 1,00 220 7 - 3,48 3,13 2,78 2,46 1,92 1,36 310 13 - 4,11 3,71 3,40 3,09 2,55 2,01 360 20 - 4,52 4,09 3,72 3,37 2,78 2,21 400 24 - 46 41 38 35 30 22 0,70 1C 1/2”G F 47 42 39 36 31 22 0,70 1C 1/2”G F 48 44 40 37 30 23 1 1C 1/2”G F 49 45 41 38 31 23 1 1C 1/2”G F 48 44 40 37 31 24 1,40 1C 1/2”G F 49 45 41 38 32 24 1,40 1C 1/2”G F 51 47 43 41 33 25 1,40 2C 1/2”G F 52 48 44 42 34 25 1 2C 1/2”G F 51 47 44 40 33 26 1,80 2C 1/2”G F 52 48 45 42 34 26 1,40 2C 1/2”G F 52 48 45 41 35 26 2,20 2C 1/2”G F 53 49 46 42 36 26 2,20 2C 1/2”G F 411 495 225 12 411 495 225 14 601 495 225 15 601 495 225 17 791 495 225 18 791 495 225 20 791 495 225 20 791 495 225 22 981 495 225 23 981 495 225 25 1171 495 225 27 1171 495 225 29 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l inch inch W 33 33 34 34 37 37 59 59 72 72 74 74 W 4 4 4 4 4 4 7 7 7 7 7 7 0,49 0,49 0,57 0,57 0,58 0,58 A 0,29 0,29 0,29 0,29 0,31 0,31 V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground 238 Dimension H H L P L P 239 Hydronic terminals NFT 102÷703 Versions I U version without cabinet version with cabinet Features Plastic air intake and outlet grille; Very low noise fan unit; 6-speed autotransformer; Air filter on all models; Cabinet in galvanised steel for maximum resistance to rust; Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40); Lockable control covers; Plug-in controls fixing bracket; Main accessories Residential fan-coils with cabinet or built-in version 0,86 - 4,25 kW Unit Description NFT belongs to residential fan coil range by Climaveneta. This compact fan coil incorporates a tangential low noise fan. They are designed for residential market and small tertiary installation. Wall-mounted LIFE controls: NSW, PSW, MTW, ATW could be connected. NFT participates to EUROVENT certification programme. Commands NSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW wall mounted Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/ winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW wall mounted Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. CE Plug-in Control for plug-in installation on fan coil. Off/summer/winter/auto selector switch. Three speed/auto selector switch. Thermostat with set point regulation. Air and water probe. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). PCE wall-mounted Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. 240 UÊPair of decorative and structural feet UÊAir intake grille kit with version cover UÊIR reciver for CE comand with remote control UÊInterface SPB Kit UÊRear panel for vertical housing UÊHorizontal and vertical fan coil auxiliary tray UÊHose kit UÊIn-line delivery plenum kit UÊFront air intake plenum for built-in version UÊManual external air intake lock kit UÊMain coil valve unit ON/OFF, PWM UÊAdditional coil valve unit ON/OFF, PWM CONTROLLER 4 PIPES TANGENZIALE FAN COIL 2 PIPES NFT / U Models Air flow rate Max speed Med speed Min speed Total output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Sensible output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Max speed (2) Med speed (2) Min speed (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Max speed (3) Med speed (3) Min speed (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Max speed (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Max speed (4) Med speed (4) Min speed (4) Sound power (5) Max speed (5) Med speed (5) Min speed (5) Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION With Cabinet L H P Weight 102 202 302 402 502 603 m3/h m3/h m3/h 310 250 175 310 250 175 410 330 250 410 330 250 590 450 300 610 470 320 kW kW kW 0,86 0,62 0,49 1,51 1,18 0,85 2,02 1,7 1,35 2,51 2 1,63 3,4 2,75 1,95 4,25 3,5 2,4 kW kW kW l/h kPa 0,8 0,56 0,4 147 10,6 1,22 0,92 0,67 259 9 1,67 1,36 1,05 346 24,5 1,97 1,52 1,23 430 27,1 2,65 2,05 1,4 580 28 3,32 2,65 1,75 730 25,6 kW kW kW l/h kPa 2,3 1,9 1,42 200 3 3,5 3 2,2 307 3 4,6 3,8 3 404 9 5,7 4,5 3,6 499 13 7 5,8 4,5 614 16 9,5 7,2 5,5 830 14 kW kW kW l/h kPa 1,25 0,97 0,8 147 10,4 1,95 1,6 1,3 259 8,2 2,6 2,3 1,8 346 22,9 2,86 2,35 1,94 430 24,9 4,2 3,3 2,5 580 27 5,26 4,23 2,91 730 17 kW l/h kPa 2,1 180 3 2,1 180 3 2,7 240 9 2,9 250 10 3,3 310 11 3,8 330 13 dB(A) dB(A) dB(A) 37 30 30 41 34 25 41 33 23 41 37 24 48 36 33 48 45 29 dB(A) dB(A) dB(A) 48 41 41 52 45 36 52 44 34 52 48 35 59 47 44 59 56 40 inch inch W A V-Ph~Hz (mm) (mm) (mm) kg 1/2” G F 1/2” G F 48 0,23 230V~50Hz 50 0,24 230V~50Hz 58 0,25 230V~50Hz 58 0,25 230V~50Hz 68 0,35 230V~50Hz 68 0,35 230V~50Hz 720 535 200 18 720 535 200 19 910 535 200 22 910 535 200 23 1100 535 200 25 1100 535 200 27 Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Noise level measured at 1 m in open field conditions 5 Sound power on the basis of measurements made in compliance with Eurovent 8/2 241 NFT / I Models Air flow rate Max speed Med speed Min speed Total output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Sensible output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Max speed (2) Med speed (2) Min speed (2) Max Water flow (2) Max Pressure drop (2) Total output heating capacity (3) Max speed (3) Med speed (3) Min speed (3) Water flow Max (3) Pressure drop Max (3) Output supplementary coil (2) Max speed (2) Water flow Max (2) Pressure drop Max (2) Sound pressure level (4) Max speed (4) Med speed (4) Min speed (4) Sound power (5) Max speed (5) Med speed (5) Min speed (5) Fan Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 102 202 302 402 502 603 m3/h m3/h m3/h 310 250 175 310 250 175 410 330 250 410 330 250 590 450 300 610 470 320 kW kW kW 0,86 0,62 0,49 1,51 1,18 0,85 2,02 1,7 1,35 2,51 2 1,63 3,4 2,75 1,95 4,25 3,5 2,4 kW kW kW l/h kPa 0,8 0,56 0,4 147 10,6 1,22 0,92 0,67 259 9 1,67 1,36 1,05 346 24,5 1,97 1,52 1,23 430 27,1 2,65 2,05 1,4 580 28 3,32 2,65 1,75 730 25,6 kW kW kW l/h kPa 2,3 1,9 1,42 200 3 3,5 3 2,2 307 3 4,6 3,8 3 404 9 5,7 4,5 3,6 499 13 7 5,8 4,5 614 16 9,5 7,2 5,5 830 14 kW kW kW l/h kPa 1,25 0,97 0,8 147 10,4 1,95 1,6 1,3 259 8,2 2,6 2,3 1,8 346 22,9 2,86 2,35 1,94 430 24,9 4,2 3,3 2,5 580 27 5,26 4,23 2,91 730 17 kW l/h kPa 2,1 180 3 2,1 180 3 2,7 240 9 2,9 250 10 3,3 310 11 3,8 330 13 dB(A) dB(A) dB(A) 37 30 30 41 34 25 41 33 23 41 37 24 48 36 33 48 45 29 dB(A) dB(A) dB(A) 48 41 41 52 45 36 52 44 34 52 48 35 59 47 44 59 56 40 inch inch W A V-Ph~Hz 1/2” G F 1/2” G F (mm) (mm) (mm) kg 48 0,23 230V~50Hz 50 0,24 230V~50Hz 58 0,25 230V~50Hz 58 0,25 230V~50Hz 68 0,35 230V~50Hz 68 0,35 230V~50Hz 545 503 195 13 545 503 195 14 735 503 195 15 735 503 195 16 925 503 195 18 925 503 195 20 Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 4 Noise level measured at 1 m in open field conditions 5 Sound power on the basis of measurements made in compliance with Eurovent 8/2 Dimension H H L P P L 242 243 Hydronic terminals MHD 30÷60 Versions - base version Features Fan coil in ABS with high mechanical characteristics and resistance to ageing; Adjustable air flow direction; Arrangement for right-left condensate drain pipe; Removable panel; Management of all functions by remote control Main accessories UÊFrame kit UÊSolenoid valve 2 ways 1/2” UÊSolenoid valve kit 3 ways, 4 fits 1/2” with frame UÊCondensate drain pump Hydronic hi-wall fan-coil 2,15 - 4,7 kW Unit Description MHD belongs to hi-wall fan-coils of Climaveneta. The compactness of this model and its exclusive elegance soften the visual impact and make it ideal for residential and small tertiary installations. Commands Remote control Set-point regulation. Selection of functioning mode (cool, heat, dehumidify, fan), fan speed (Max, Med, Min, AUTO). Main available function: Swing, Sleep, Timer. User-sfriendly compact remote control with fine aethetics. 244 CONTROLLER WALL 2 PIPES TANGENZIALE MHD / Models Air flow rate Max speed Med speed Min speed Total output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Sensible output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Max Water flow (1) Max Pressure drop (1) Total output heating capacity (2) Max speed (2) Med speed (2) Min speed (2) Water flow Max (2) Pressure drop Max (2) Sound power (3) Max speed (3) Med speed (3) Min speed (3) Water IN connection Water OUT connection Max absorbed power Max absorbed current Electrical power supply DIMENSION L H P Weight 30 40 50 60 m3/h m3/h m3/h 436 376 334 632 522 403 780 691 570 920 810 697 kW kW kW 2,15 1,85 1,65 2,80 2 1,75 4 3,40 3,10 4,70 3,90 3,35 kW kW kW l/h kPa 1,82 1,60 1,45 2,48 1,75 1,55 3,40 2,90 2,60 3,60 3,30 2,85 10 16 37 46 kW kW kW l/h kPa dB(A) dB(A) dB(A) dB(A) mm mm W A V-Ph~Hz 2,70 2,30 1,98 3,60 2,55 2,20 4,90 4,20 3,80 5,80 4,85 4,15 9 15 35 4 45 42 38 12 12 24 52 42 39 12 12 28 55 52 48 12 12 40 60 56 53 12 12 50 230-1-50 230-1-50 230-1-50 230-1-50 845 270 180 10 845 270 180 10 940 298 200 13 940 298 200 13 mm mm mm kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 3 Sound power on the basis of measurements made in compliance with Eurovent 8/2 Dimension A L P 245 Hydronic terminals HWD 602÷1104 Versions E base version electronic regulation version with remote control Features Unit coils guarantee high efficiency thermal exchange with low pressure drop. Finned unit coils are made of copper tubes and high exchange surface area aluminium fins. Coils are always tested for leaks with dried air at 30 bar; Electrical power and control switchboard complete with electronic air flow regulator and terminal blocks for connection to power supply and remote control; Internal insulation in closed cell expanded polyethylene with suitable thick to limit heat loss and noise emission; The fan unit high pressure are fitted with balanced impellers to guarantee minimum noise levels; Structure and base plate in hot-dip galvanised steel for maximum resistance to rust; Extra modules available as accessories to the standard unit; Remote control to manage main unit functions to provide a total enviroment comfort. Full Auto function; Arrangement for electronic control of two on/off or modulating valve unit in the water circuit; Ducted type terminal Main accessories 4,8 - 15,1 kW Unit Description HWD are Climaveneta ducted hydronic terminal units. The fan units at available working pressures, through internal insulation, ensure excellent acoustic comfort levels. The compactness and ease of installation make HWD a suitable hydronic terminal unit for any type of setting. Commands NSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW wall mounted Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/ winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW wall mounted Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. PCE wall-mounted Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. 250 UÊInterface SPB Kit UÊHot water coil kit UÊAir purifier module with actived carbon filter UÊHeating element module UÊHumidifier module UÊDelivery and intake plenum UÊDelivery plenum for round ducts UÊTwo way intake plenum with air lock UÊCondensate drain pump CONTROLLER 4 PIPES CENTRIFUGAL DUCT 2 PIPES HWD / Models Air flow rate Max speed Med speed Min speed Useful head (basic unit with filter) Total output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Sensible output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Max Pressure drop (1) Total output heating capacity (2) Max speed (2) Med speed (2) Min speed (2) Pressure drop Max (2) Output supplementary coil (3) Max speed (3) Pressure drop Max (3) Sound power (4) Max speed (4) Med speed (4) Min speed (4) Hydraulic connections main coil Hydraulic connections supplementary coil Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 602 703 803 904 1003 1104 m3/h m3/h m3/h Pa 1300 1171 1021 60 1300 1171 1021 60 1600 1357 1057 60 1600 1357 1057 60 2200 1985 1585 60 2500 2243 1771 60 kW kW kW 4,80 4,50 4,10 6,20 5,70 5,20 8,00 7,20 6,00 9,70 8,50 7,00 11,5 10,7 9,10 15,1 13,9 11,7 kW kW kW kPa 3,00 2,80 2,60 12 4,00 3,70 3,40 8 5,20 4,60 3,90 14 6,50 5,90 4,80 13 7,40 6,90 6,00 24 10,2 9,70 8,00 23 kW kW kW kPa 6,61 6,19 5,65 10 8,48 7,88 7,13 7 10,5 9,34 7,75 12 12,1 10,7 8,73 11 14,8 13,7 11,6 21 18,7 17,3 14,3 20 kW kPa 9,10 9 9,10 9 11,8 14 11,8 14 16,7 13 18,0 15 dB(A) dB(A) dB(A) inch 68 65 62 1/2” 68 65 62 1/2” 72 69 63 3/4” 72 69 63 3/4” 78 76 70 1” 80 77 72 1” inch 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 370 1,30 230V~50Hz 370 1,30 230V~50Hz 440 1,55 230V~50Hz 440 1,55 230V~50Hz 900 3,50 230V~50Hz 900 3,50 230V~50Hz 900 295 695 41 900 295 695 43 1050 295 695 50 1050 295 695 52 1250 315 750 63 1250 315 750 63 W A V-Ph~Hz (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 4 Sound power on the basis of measurements made in compliance with Eurovent 8/12 251 HWD / E Models Air flow rate Max speed Med speed Min speed Useful head (basic unit with filter) Total output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Sensible output cooling capacity (1) Max speed (1) Med speed (1) Min speed (1) Max Pressure drop (1) Total output heating capacity (2) Max speed (2) Med speed (2) Min speed (2) Pressure drop Max (2) Output supplementary coil (3) Max speed (3) Pressure drop Max (3) Sound power (4) Max speed (4) Med speed (4) Min speed (4) Hydraulic connections main coil Hydraulic connections supplementary coil Max absorbed power Max absorbed current Electrical power supply DIMENSION Built-in L H P Weight 602 703 803 904 1003 1104 m3/h m3/h m3/h Pa 1300 1171 1021 60 1300 1171 1021 60 1600 1357 1057 60 1600 1357 1057 60 2200 1985 1585 60 2500 2243 1771 60 kW kW kW 4,80 4,50 4,10 6,20 5,70 5,20 8,00 7,20 6,00 9,70 8,50 7,00 11,5 10,7 9,10 15,1 13,9 11,7 kW kW kW kPa 3,00 2,80 2,60 12 4,00 3,70 3,40 8 5,20 4,60 3,90 14 6,50 5,90 4,80 13 7,40 6,90 6,00 24 10,2 9,70 8,00 23 kW kW kW kPa 6,61 6,19 5,65 10 8,48 7,88 7,13 7 10,5 9,34 7,75 12 12,1 10,7 8,73 11 14,8 13,7 11,6 21 18,7 17,3 14,3 20 kW kPa 9,10 9 9,10 9 11,8 14 11,8 14 16,7 13 18,0 15 dB(A) dB(A) dB(A) inch 68 65 62 1/2” 68 65 62 1/2” 72 69 63 3/4” 72 69 63 3/4” 78 76 70 1” 80 77 72 1” inch 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 370 1,30 230V~50Hz 370 1,30 230V~50Hz 440 1,55 230V~50Hz 440 1,55 230V~50Hz 900 3,50 230V~50Hz 900 3,50 230V~50Hz 900 295 695 41 900 295 695 43 1050 295 695 50 1050 295 695 52 1250 315 750 63 1250 315 750 63 W A V-Ph~Hz (mm) (mm) (mm) kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 4 Sound power on the basis of measurements made in compliance with Eurovent 8/12 Dimension P H L 252 253 Hydronic terminals HWD-HP 0071÷0121 Versions - base version Features Unit coils guarantee high efficiency thermal exchange with low pressure drop. Finned unit coils are made of copper tubes and high exchange surface area aluminium fins. Coils are always tested for leaks with dried air at 30 bar; The electrical power and control switchboard includes electronic air flow regulator and terminal blocks for connection to power supply and remote control; Internal insulation in closed cell expanded polyethylene with suitable thick to limit heat loss and noise emission; The fan unit high pressure are fitted with balanced impellers to guarantee minimum noise levels; Cabinet in galvanised steel for maximum resistance to rust; Extra modules available as accessories to the standard unit; Main accessories UÊInterface SPB Kit UÊHot water coil kit UÊHeating element module UÊDelivery and intake plenum UÊIntake grill UÊTwo way intake plenum with air lock UÊCeiling brackets UÊAuxiliary condensate collecting tray High head ducted type terminal 16,8 - 29,8 kW Unit Description HWD HP belongs to ducted type fan-coils high head of Climaveneta. The possibility of vertical or horizontal installation, airflow adjustment and attractive external panelling guarantees an ease installation and make the unit adaptable to any type of surroundings. Commands NSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW wall mounted Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/ winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW wall mounted Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. PCE wall-mounted Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. 254 CONTROLLER CENTRIFUGAL DUCT 4 PIPES 2 PIPES HWD-HP / Models Total output cooling capacity (1) Sensitive output cooling capacity (1) Total output heating capacity (2) Heating capacity standard coil (3) Output supplementary coil (3) Pressure drop main coil (1) Pressure drop additional coil (3) Absorbed power Absorbed current at nominal conditions Nominal air flow Useful head (basic unit with filter) Hydraulic connections main coil Hydraulic connections supplementary coil Sound pressure level (4) Electrical power supply DIMENSION L H P Weight kW kW kW kW kW kPa kPa kW A 0071 0091 0101 0121 16,8 12,3 16,3 34,6 25 24 14 0,68 20 14,4 19,6 40 25 22 14 0,68 23,4 17,3 23 47,8 36 14 19 1,75 29,8 21,7 29,5 60,4 39 12 22 2,24 2,9 2,9 7,9 9,5 m3/h Pa inch 3200 105 1”1/4 3200 93 1”1/4 4400 250 1”1/2 5000 141 1”1/2 inch 3/4” 3/4” 1 1 60 230V~50Hz 60 230V~50Hz 66 230V~50Hz 69 230V~50Hz 1300 510 1119 121 1300 510 1119 124 1500 625 1349 145 1500 625 1349 149 dB(A) V-Ph~Hz mm mm mm kg Note: 1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C 2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 45°C and at outlet 40°C 3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C 4 Noise level measured at 1 m in open field conditions Dimension P L H 255 Hydronic terminals HRD 0021÷0151 Versions - base version Features Removable aluzink plate side panels; Panels insulated and soundproofed with polyethylene/ polyester with average thickness of 10 mm (mod. HRD 0021-0051) and 20 mm for the other models; High efficiency aluminium plate static type heat recovery units, with airflow separated by special seals; UE3 efficiency air filters, which may be easily removed from any side of the unit (bottom, side, top) for periodic cleaning; Fan casings on vibration-isolation mountings; Double inlet centrifugal fans for fresh air intake and used air extraction, which may be removed from any side of the unit for periodic maintenance; Multi speed directly coupled electric motor; A terminal block with a relay board is fitted on the unit to aid electrical connections and fan control; Stainless steel condensate collecting tray, with condensate drain directed downwards; Main accessories UÊInterface SPB Kit UÊHot water coil kit UÊCool water coil kit UÊHeating element kit Heat recuperator unit 290 - 4000 m3/h Unit Description HRD heat recuperator units for residential and commercial application allow maximum room comfort and energy saving. In modern systems is becoming necessary to create forced ventilation, which involves air conditioned expelling; thereby consuming more energy and consequenting increasing costs. HRD heat recuperators have obviated such as problems using an aluminium static recovery unit that saves more than 50% energy, otherwise be lost with expelled stale air. HRD can be integrated in traditional systems with fan coils, chillers and radiators and may operate both in summer and winter. These units are recommended for suspended ceiling installation and may be suitably ducted to allow the fresh air intake and distribution. Commands NSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW wall mounted Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/ OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW wall mounted Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/ winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW wall mounted Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. PCE wall-mounted Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. 256 CONTROLLER PLATE CENTRIFUGAL HRD / Models Max air flow Sound level Max (1) Axle power available Poles Max absorption N° fan speeds Efficiency Recuperated thermal power Renewal air temperature Efficiency Frontal air speed Protection grade Isolation grade ESP Electrical power supply internal unit DIMENSION L H P Net weight m3/h dB(A) W N° A N° % kW °C m/s IP Pa V-Ph~Hz 0021 0031 0051 0071 0091 0101 0121 0151 290 54 2x45 4 1,3 2 52,3 1 8,10 G3 1,7 20 B 40 230V~50Hz 600 56 2x90 2 1,8 1 54,6 3 8,70 G3 3,6 54 F 80 230V~50Hz 1000 54 2x147 4 3,0 3 53,4 5 8,30 G3 2,9 44 F 90 230V~50Hz 1400 59,5 2x350 4 5,8 3 52,1 6 8,00 G3 4,1 55 F 140 230V~50Hz 1900 58 2x350 4 6,2 3 51,8 8 7,90 G3 4,5 44 F 120 230V~50Hz 2500 57,5 2x350 4 6,0 3 57,6 12 9,40 G3 3,8 55 F 110 230V~50Hz 3200 60,5 2x550 4 11,4 3 56,0 15 9,00 G3 4,3 20 F 170 230V~50Hz 4000 62 2x750 4 6,2 2 55,6 19 8,90 G3 4,3 55 F 170 400V-3N~50Hz 990 270 750 39 990 270 750 41 1150 385 860 68 1350 410 900 91 1450 470 900 99 1700 490 1230 140 1700 530 1230 155 1700 630 1230 179 mm mm mm kg Note: 1 Sound pressure measured at 1 m in open field conditions Dimension H L P 257 H HP 258 PAC HPAC HPAC 259 HPAC i-AX 18÷90 Versions STD MOD LT base version with fan speed regulation for i-BRE version with condensing fan speed regulation low outdoor temperature version with condensing fan speed regulation Features Unit for installing inside or outside the room to be airconditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material to limit noise levels. The reliability and functionality of the compressor and all the other parts are guaranteed by partners who are world leaders in their sector. Close control unit, direct expansion air cooled with INVERTER compressor 7 - 100 kW Unit Description Ductable close control units air-conditioners with capacity ranging from 7 to 100 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifer and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. The INVERTER compressor allows the cooling capacity modulation according to the real internal load, particularly efficient at the partial loads and optimizing the power absorbed and eliminating the start current. Units fitted with electronic expansion valve and EC INVERTER fans, upflow or downflow. Commands EVOLUTION Semi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm, Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 260 NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. Condensing control for maximum low noise (optional). Standard G2/G4 filtering section, F6-F8 optional, to CENEN 779 with average degree of separation 90.1% ASHRAE. The filter is self-extinguishing. The microprocessor controls the compressor activation times with FIFO logic, thereby regulating the cooling capacity; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Switchboard to IEC 204-1/EN60204-1 Refrigerant circuit consisting in the standard version of a electronic expansion valve, liquid solenoid valve, high/low pressure switch, sight glass liquid indicator drier filter and oil separator in order to guarantee the right lubrification of the compressor at the low speed. Capillary Pre and After sales service. Main accessories • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board Inverter i-AX Models 18 29 50 70 Frame F2 F3 F4 F5 F6 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1 1 1 2 2 Power supply V/Ph/Hz Refrigerant N° compressors 90 PERFORMANCES High Speed Total cooling capacity (1) kW 16,60 28,07 53,14 68,40 84,68 Sensible cooling capacity (1) kW 16,60 28,07 50,30 67,30 84,68 SHR (1) 1,00 1,00 0,95 0,98 1,00 4,09 7,14 13,92 16,47 21,03 3,65 3,24 3,12 3,25 3,12 Total compressors absorbed power kW EER Low speed Total cooling capacity (1) kW 6,27 10,62 23,68 22,06 22,70 Sensible cooling capacity (1) kW 6,27 10,62 23,68 22,06 22,70 SHR (1) 1,00 1,00 1,00 1,00 1,00 kW 1,24 1,96 4,85 4,82 4,83 Total compressors absorbed power Booster (not continuative functioning) Total cooling capacity (1) kW 20,42 34,77 56,52 85,31 93,47 Sensible cooling capacity (1) kW 18,44 31,10 51,30 74,60 89,77 SHR (1) 0,90 0,89 0,91 0,87 0,96 kW 5,66 8,00 15,24 22,49 24,49 mc/h 4900 8000 13500 19000 25000 kW 0,47 1,51 3,13 4,57 6,1 53 60 64 67 67 Total compressors absorbed power VENTILATION Nominal air flow volume Fan absorbed power Sound pressure level (2) dB(A) HUMIDIFIER Capacity Absorbed power kg/h 5 5 5 8 8 kW 3,75 3,75 3,75 6 6 ELECTRICAL HEATERS Steps 3 3 3 3 3 kW 8 9 15 18 18 L mm 1000 1000 1550 2100 2650 P mm 500 790 790 790 790 H mm 1980 1980 1980 1980 1980 Absorbed power DIMENSIONS NOTE (1) Indoor conditions: 24°C-50% Condensing temp. 45°C - ESP 20Pa (2) Measured at 1,5 m height, 2 m in front of the unit in free field H P 261 L HPAC i-AW 18÷90 Versions STD base version with fan speed regulation for i-BDC MOD_A version with condensing fan speed regulation MOD_B version with condensing pressostatic regulation Features Unit for installing inside or outside the room to be airconditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material to limit noise levels. The reliability and functionality of the compressor and all the other parts are guaranteed by partners who are world leaders in their sector. Close control unit, direct expansion water cooled with INVERTER compressor 7 - 100 kW Unit Description Ductable close control units air-conditioners with capacity ranging from 7 to 100 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifer and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. The INVERTER compressor allows the cooling capacity modulation according to the real internal load, particularly efficient at the partial loads and optimizing the power absorbed and eliminating the start current. Units fitted with electronic expansion valve and EC INVERTER fans, upflow or downflow. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. Condensing control for maximum low noise (optional). Standard G2/G4 filtering section, F6-F8 optional, to CENEN 779 with average degree of separation 90.1% ASHRAE. The filter is self-extinguishing. The microprocessor controls the compressor activation times with FIFO logic, thereby regulating the cooling capacity; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Switchboard to IEC 204-1/EN60204-1 Refrigerant circuit consisting in the standard version of a electronic expansion valve, liquid solenoid valve, high/low pressure switch, sight glass liquid indicator drier filter and oil separator in order to guarantee the right lubrification of the compressor at the low speed. Capillary Pre and After sales service. Main accessories Commands EVOLUTION Semi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm, Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 262 • • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Special filter plenum for air outlet Interface electronic board Inverter i-AW Models 18 29 50 70 Frame F2 F3 F4 F5 F6 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1 1 1 2 2 Power supply V/Ph/Hz Refrigerant N° compressors 90 PERFORMANCES High Speed Total cooling capacity (1) kW 17,35 29,32 55,00 72,25 91,52 Sensible cooling capacity (1) kW 17,04 28,60 50,80 69,48 89,80 SHR (1) 0,98 0,98 0,92 0,96 0,98 3,68 6,38 13,02 14,47 19,64 4,18 3,71 3,40 3,80 3,56 Total compressors absorbed power kW EER Low speed Total cooling capacity (1) kW 7,27 12,33 25,67 23,61 25,36 Sensible cooling capacity (1) kW 7,27 12,33 25,67 23,61 25,36 SHR (1) 1,00 1,00 1,00 1,00 1,00 kW 0,96 1,43 3,83 3,99 3,92 Total compressors absorbed power Booster (not continuative functioning) Total cooling capacity (1) kW 21,69 35,30 58,07 88,03 100,09 Sensible cooling capacity (1) kW 18,96 31,10 52,00 75,90 93,10 SHR (1) 0,87 0,88 0,90 0,86 0,93 kW 4,97 7,83 14,46 21,00 23,64 mc/h 4900 8000 13500 19000 25000 kW 0,47 1,51 3,13 4,57 6,1 53 60 64 67 67 Total compressors absorbed power VENTILATION Nominal air flow volume Fan absorbed power Sound pressure level (2) dB(A) HUMIDIFIER Capacity Absorbed power kg/h 5 5 5 8 8 kW 3,75 3,75 3,75 6 6 ELECTRICAL HEATERS Steps 3 3 3 3 3 kW 8 9 15 18 18 L mm 1000 1000 1550 2100 2650 P mm 500 790 790 790 790 H mm 1980 1980 1980 1980 1980 Absorbed power DIMENSIONS NOTE (1) Indoor conditions :24°C-50% Water 30- 35°C - ESP 20Pa (2) Measured at 1,5 m height, 2 m in front of the unit in free field H P 263 L HPAC AX 07÷90 Versions STD LT MOD base version low outdoor temperature version with condensing fan speed regulation version with condensing fan speed regulation Features Close control unit, air cooled, direct expansion 7 - 90 kW Unit Description Ductable close control air-conditioners with capacities ranging from 7 to 90 kW for vertical installation and cooling only, with optional heating by means of heating element or hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air-conditioning technological, server and CED rooms and all technological applications in general. Units fitted with centrifugal fans with upward airflow from the top or from the bottom. External air condenser. Power supply 400V/3+N/50Hz (all models). Commands EVOLUTION Semi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm, Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 264 Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material to limit noise levels. The reliability and functionality of the compressor and all the other parts are guaranteed by partners who are world leaders in their sector. Double-inlet centrifugal fan per standard installed, directly coupled and suspended on vibration-isolation mountings. The fans are of the forward-bladed type for maximum efficiency and low noise. Available as option, EC INVERTER fans with electronic commutation, Backward Curved Fan type to minimize energy consumption and noise emission. Condensing control for maximum low noise (optional). Standard G2/G4 filtering section, F6-F8 optional, to CEN-EN 779 with average degree of separation 90.1% ASHRAE. The filter is self-extinguishing. The microprocessor controls the compressor activation times with FIFO logic, thereby regulating the cooling capacity; it also controls the operating alarms with the possibility of interfacing to supervisor and remote-servicing systems. Switchboard to IEC 204-1/EN60204-1 Refrigerant circuit consisting in the standard version of a thermostatic valve with external equalization (electronic expansion valve avaible as option), liquid solenoid valve, high/low pressure switch, sight glass liquid indicator and drier filter. Capillary Pre and After sales service. Main accessories • • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board Electronic Thermostatic valve ACCURATE AX / STD Models Electrical power supply COOLING PERFORMANCES Total cooling capacity Sensible cooling capacity SHR COMPRESSORS Quantity Power absorbed N° Circuits Refrigerant FANS Fan air flow N° Centrifugal fans N° EC Inverter fans Centrifugal fans power abs. EC Inverter fans power abs. ESP std. Sound pressure level AIR FILTER Degree filtration HUMIDIFIER Capacity Power absorbed ELECTRICAL HEATERS Steps Power absorbed DIMENSION L P H COUPLING EXTERNAL UNIT BRE STD/LT/LN Models Electrical power supply COOLING PERFORMANCES Total cooling capacity Sensible cooling capacity SHR COMPRESSORS Quantity Power absorbed N° Circuits Refrigerant FANS Fan air flow N° Centrifugal fans N° EC Inverter fans Centrifugal fans power abs. EC Inverter fans power abs. ESP std. Sound pressure level AIR FILTER Degree filtration HUMIDIFIER Capacity Power absorbed ELECTRICAL HEATERS Steps Power absorbed DIMENSION L P H COUPLING EXTERNAL UNIT BRE STD/LT/LN 07 10 15 18 400/3+N/50 20 26 29 39 kW kW 7,20 7,20 1 9,60 9,20 0,96 16,3 16,3 1 19,1 18,2 0,95 23,3 23,3 1 28,9 28,8 1 31,8 29,9 0,94 41 41 1 n° kW n° 1 1,69 1 R410A 1 2,20 1 R410A 1 3,64 1 R410A 1 4,31 1 R410A 1 4,93 1 R410A 1 6 1 R410A 1 6,93 1 R410A 1 7,86 1 R410A 2500 1 1 0,49 0,27 20 50 2500 1 1 0,49 0,27 20 50 4900 2 2 1 0,53 20 53 4900 2 2 1 0,53 20 53 6500 1 1 1,66 0,89 20 56 8000 1 1 2,02 1,69 20 60 8000 1 1 2,02 1,69 20 60 13500 2 2 3,61 3,51 20 64 G2 G2 G2 G2 G4 G4 G4 G4 kg/h kW 3 2,25 3 2,25 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 n° kW 3 4 3 4 3 8 3 8 3 9 3 9 3 9 3 15 mm mm mm 600 500 1980 600 500 1980 1000 500 1980 1000 500 1980 1000 790 1980 1000 790 1980 1000 790 1980 1550 790 1980 014m 014m 022m 027m 027m 044m 044m 051m 30 40 50 55 60 400/3+N/50 70 80 90 kW kW 33,4 33,4 1 46,2 46,2 1 52,3 49,9 0,95 60,3 60,3 1 68,1 68,1 1 73,2 70,1 0,96 87,8 87,8 1 95,4 91,8 0,96 n° kW n° 2 7,26 2 R410A 2 9,85 2 R410A 2 12 2 R410A 2 12 2 R410A 2 13,9 2 R410A 2 15,7 2 R410A 2 17,7 2 R410A 2 21,3 2 R410A m3/h n° n° kW kW Pa dB(A) 10500 2 2 2,89 2,09 20 59 13500 2 2 3,61 3,51 20 64 13500 2 2 3,61 3,51 20 64 19000 2 3 6,55 5,11 20 67 19000 2 3 6,55 5,11 20 67 19000 2 3 6,55 5,11 20 67 25000 4 6,82 20 67 25000 4 6,82 20 67 G4 G4 G4 G4 G4 G4 G4 G4 kg/h kW 5 3,75 5 3,75 5 3,75 8 6 8 6 8 6 8 6 8 6 n° kW 3 15 3 15 3 15 3 18 3 18 3 18 3 18 3 18 mm mm mm 1550 790 1980 1550 790 1980 1550 790 1980 2100 790 1980 2100 790 1980 2100 790 1980 2650 790 1980 2650 790 1980 054b 054b 065b 065b 076b 100b 100b 116b V-Ph~Hz (1) (1) (2) m3/h n° n° kW kW Pa dB(A) V-Ph~Hz (1) (1) (2) NOTE (1) Indoor air: 24°C/50% r.h.; Condensing temp.: 45°C (2) Measured at 1,5 m high and 2 m front unit, in open field conditions 265 HPAC AW 07÷90 Versions STD base version MOD_A version with condensing fan speed regulation MOD_B version with condensing pressostatic regulation Features Close control unit, water cooled direct expansion 07 - 90 kW Unit Description Ducted close-control air-conditioners with capacities ranging from 7 to 90 kW for vertical installation and cooling only, with optional reheating by means of heating element or hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air-conditioning technological, server and CED rooms and all technological applications in general. Units fitted with centrifugal fans with upward airflow from the top and from the bottom and incorporated water-cooled condenser. External Dry Cooler. Power supply 400V/3+N/50Hz (for all units). Commands EVOLUTION Semi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm, Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 266 Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material to limit noise levels. The reliability and functionality of the compressor and all the other parts are guaranteed by partners who are world leaders in their sector. Double-inlet centrifugal fan per standard installed, directly coupled and suspended on vibration-isolation mountings. The fans are of the forward-bladed type for maximum efficiency and low noise. Available as option, EC INVERTER fans with electronic commutation, Backward Curved Fan type to minimize energy consumption and noise emission. Condensing control for maximum low noise (optional). Standard G2/G4 filtering section, F6-F8 optional, to CEN-EN 779 with average degree of separation 90.1% ASHRAE. The filter is self-extinguishing. The microprocessor controls the compressor activation times with FIFO logic, thereby regulating the cooling capacity; it also controls the operating alarms with the possibility of interfacing to supervisor and remote-servicing systems. Refrigerant circuit consisting in the standard version of a thermostatic valve with external equalization (electronic expansion valve avaible as option), liquid solenoid valve, high/low pressure switch, sight glass liquid indicator and drier filter. Switchboard to IEC 204-1/EN60204-1 Capillary Pre and After sales service. Main accessories • • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board Electronic Thermostatic valve ACCURATE AW / STD Models Electrical power supply COOLING PERFORMANCES Total cooling capacity Sensible cooling capacity SHR COMPRESSORS Quantity Power absorbed N° Circuits Refrigerant FANS Fan air flow N° Centrifugal fans N° EC Inverter fans Centrifugal fans power abs. EC Inverter fans power abs. ESP std. Sound pressure level AIR FILTER Degree filtration HUMIDIFIER Capacity Power absorbed ELECTRICAL HEATERS Steps Power absorbed PLATE CONDENSER Water flow rate Pressure drop DIMENSION L P H COUPLING EXTERNAL UNIT BDC STD/LT/LN 07 10 15 18 400/3+N/50 20 26 29 39 kW kW 7,50 7,50 1 9,80 9,30 0,95 16,9 16,9 1 19,8 18,3 0,92 24,5 23,8 0,97 29,2 28,3 0,97 33 29,9 0,91 43 43 1 n° kW n° 1 1,47 1 R410A 1 1,91 1 R410A 1 3,26 1 R410A 1 3,93 1 R410A 1 4,28 1 R410A 1 5,38 1 R410A 1 6,24 1 R410A 1 6,91 1 R410A 2500 1 1 0,49 0,27 20 50 2500 1 1 0,49 0,27 20 50 4900 2 2 1 0,53 20 53 4900 2 2 1 0,53 20 53 6500 1 1 1,66 0,89 20 56 8000 1 1 2,02 1,69 20 60 8000 1 1 2,02 1,69 20 60 13500 2 2 3,61 3,51 20 64 G2 G2 G2 G2 G4 G4 G4 G4 kg/h kW 3 2,25 3 2,25 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 n° kW 3 4 3 4 3 8 3 8 3 9 3 9 3 9 3 15 l/h kPa 1520 8 2050 14 3390 57 4020 23 4820 30 5930 27 6730 24 8360 30 mm mm mm 600 500 1980 600 500 1980 1000 500 1980 1000 500 1980 1000 790 1980 1000 790 1980 1000 790 1980 1550 790 1980 013m 013m 030m 030m 030m 039m 039m 052m 50 55 60 400/3+N/50 70 80 90 54,5 49,9 0,92 62,6 62,6 1 70,8 69,1 0,98 77,4 71,1 0,92 90,6 90 0,99 99,3 92,8 0,93 2 10,8 2 R410A 2 10,8 2 R410A 2 12,4 2 R410A 2 13,5 2 R410A 2 15,9 2 R410A 2 19,2 2 R410A 13500 2 2 3,61 3,51 20 64 19000 2 3 6,55 5,11 20 67 19000 2 3 6,55 5,11 20 67 19000 2 3 6,55 5,11 20 67 25000 4 6,82 20 67 25000 4 6,82 20 67 G4 G4 G4 G4 G4 G4 5 3,75 8 6 8 6 8 6 8 6 8 6 3 15 3 18 3 18 3 18 3 18 3 18 5715x2 30 6155x2 33 6975x2 30 7705x2 26 17850 31 20160 39 1550 790 1980 2100 790 1980 2100 790 1980 2100 790 1980 2650 790 1980 2650 790 1980 062m 078m 078m 092m 103m 123m V-Ph~Hz (1) (1) (2) (1) (1) m3/h n° n° kW kW Pa dB(A) Models 30 40 Electrical power supply V-Ph~Hz COOLING PERFORMANCES Total cooling capacity (1) kW 34,8 48,5 Sensible cooling capacity (1) kW 34,8 48,4 SHR 1 1 COMPRESSORS Quantity n° 2 2 Power absorbed kW 6,42 8,53 N° Circuits n° 2 2 Refrigerant R410A R410A FANS Fan air flow m3/h 10500 13500 N° Centrifugal fans n° 2 2 N° EC Inverter fans n° 2 2 Centrifugal fans power abs. kW 2,89 3,61 EC Inverter fans power abs. kW 2,09 3,51 ESP std. Pa 20 20 Sound pressure level (2) dB(A) 59 64 AIR FILTER Degree filtration G4 G4 HUMIDIFIER Capacity kg/h 5 5 Power absorbed kW 3,75 3,75 ELECTRICAL HEATERS Steps n° 3 3 Power absorbed kW 15 15 PLATE CONDENSER Water flow rate (1) l/h 3460x2 4780x2 Pressure drop (1) kPa 21 DIMENSION L mm 1550 1550 P mm 790 790 H mm 1980 1980 COUPLING EXTERNAL UNIT BDC STD/LT/LN 039m 052m NOTE (1) Indoor air: 24°C/50% r.h.; Water: 30°-35°C (2) Measured at 1,5 m high and 2 m front unit, in open field conditions 267 HPAC AD 20÷90 Versions STD base version LT low outdoor temperature version with condensing fan speed regulation MOD version with condensing fan speed regulation Features Unit for installing inside or outside the room to be air-conditioned Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. Standard G4 filtering section, F6-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. Capillary Pre and After sales service. Close control unit dual fluid, air cooled direct expansion 20 - 100 kW Main accessories Unit Description Ductable close control units air-conditioners with capacity ranging from 20 to 100 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifer and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fittend with EC INVERTER fans, upflow or downflow. DUAL FLUID unit has to be connected to an external chiller for PRIMARY circuit. The direct expansion circuit, secondary or BACK-UP circuit, is air cooled and has to be connected with a remote condenser. Commands EVOLUTION Semi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm, Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 268 • • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board Electronic Thermostatic valve ACCURATE AD/STD Models 20 Electrical power supply 26 29 39 30 V-Ph~Hz 40 50 60 70 80 90 98,8 400/3+N/50 COOLING PERFORMANCES (DX) Total cooling capacity (1) kW 23,7 29,4 32,7 42,2 36,7 47,6 55,1 62,1 75,5 86,3 Sensible cooling capacity (1) kW 21,8 27,9 30,2 42,2 36,2 47 50,7 62,1 71 86,1 91 0,92 0,95 0,92 1 0,99 0,99 0,92 1 0,94 1 0,92 SHR COMPRESSORS Quantity n° 1 1 1 1 2 2 2 2 2 2 2 Power abs. kW 4,93 6,01 6,75 7,87 7,15 9,87 11,7 12 15,4 17,7 21,4 N° Circuits n° Refrigerant 1 1 1 1 2 2 2 2 2 2 2 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 91 COOLING PERFORMANCES (CW) Total cooling capacity (2) kW 23,8 28,1 29,5 20 41 50 51,4 65 67,6 91 Sensible cooling capacity (2) kW 21,8 26,4 27,6 46,3 37 46,3 47,5 62,2 64,5 85 85 0,92 0,94 0,94 0,93 0,90 0,93 0,92 0,96 0,95 0,93 0,93 SHR Water flow rate (2) Total pressure drop water side l/h 3890 4590 4590 8170 6710 8170 8170 10630 10630 14870 14870 kPa 26 35 35 46 30 46 46 26 26 53 53 mc/h 24000 VENTILATION Air flow N° EC Inverter fans EC Inverter fans power abs. ESP std. Sound pressure level (3) 6000 7500 8000 13000 10000 13000 13500 18000 19000 24000 n° 1 1 1 2 2 2 2 3 3 4 4 kW 0,89 1,60 1,80 3,40 2,09 3,40 3,65 4,50 5,20 6,82 6,82 Pa 20 20 20 20 20 20 20 20 20 20 20 dB(A) 56 60 60 64 59 64 64 67 67 67 67 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 AIR FILTER Degree filtration HUMIDIFIER Capacity Power abs. kg/h 5 5 5 5 5 5 5 8 8 8 8 kW 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6 ELECTRICAL HEATERS Steps 3 3 3 3 3 3 3 3 3 3 3 kW 9 9 9 15 15 15 15 18 18 18 18 L mm 1000 1000 1000 1550 1550 1550 1550 2100 2100 2650 2650 P mm 790 790 790 790 790 790 790 790 790 790 790 H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 027m 044m 044m 051m 054b 054b 065b 076b 100b 100b 116b Power abs. DIMENSION COUPLING EXTERNAL UNIT BRE STD/LT/LN NOTE (1) Indoor air: 24°C/50% r.h.; Condensing temp.: 45°C (2) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C (3) Measured at 1,5 m high and 2 m front unit, in open field conditions H P 269 L HPAC AT 20÷90 Versions STD base version MOD_A version with condensing fan speed regulation MOD_B version with condensing pressostatic regulation Features Close control unit dual fluid, water cooled direct expansion 20-100kW Unit Description Ductable close control units air-conditioners with capacity ranging from 20 to 100 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifer and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fittend with EC INVERTER fans, upflow or downflow. DUAL FLUID unit has to be connected to an external chiller for PRIMARY circuit. The direct expansion circuit, secondary or BACK-UP circuit, is water cooled and has to be connected with a remote dry cooler or to city water net. Commands EVOLUTION Semi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm, Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 270 Unit for installing inside or outside the room to be air-conditioned Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. Standard G4 filtering section, F6-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. Capillary Pre and After sales service. Main accessories • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Air distribution plenum Sound absorber plenum for air outlet Interface electronic board Electronic Thermostatic valve ACCURATE AT/STD Models 20 Electrical power supply 26 29 39 30 V-Ph~Hz 40 50 60 70 80 90 400/3+N/50 COOLING PERFORMANCES (DX) Total cooling capacity (1) kW 24,9 30,6 32,3 47,3 47,3 50 54,5 70,3 76,6 91,8 102 Sensible cooling capacity (1) kW 22,8 28,3 30 46,9 46,9 47,9 50,7 66,8 71,1 88,2 92,2 0,92 0,92 0,93 0,99 0,99 0,96 0,93 0,95 0,93 0,96 0,90 SHR COMPRESSORS Quantity n° 1 1 1 1 2 2 2 2 2 2 2 Power abs. kW 4,30 5,40 6,11 6,94 6,44 8,61 10,6 12,3 13,3 16 19,3 N° Circuits n° Refrigerant 1 1 1 1 2 2 2 2 2 2 2 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 91 COOLING PERFORMANCES (CW) Total cooling capacity (2) kW 23,8 28,1 29,5 50 41 50 51,4 65 67,6 91 Sensible cooling capacity (2) kW 21,8 26,4 27,6 46,3 37 46,3 47,5 62,2 64,5 85 85 0,92 0,94 0,94 0,93 0,90 0,93 0,92 0,96 0,95 0,93 0,93 SHR Water flow rate (2) l/h 3890 4590 4590 8170 6710 8170 8170 10630 10630 14870 14870 Total pressure drop water side (2) kPa 26 35 35 46 30 46 46 26 26 53 53 mc/h 24000 VENTILATION Air flow N° EC Inverter fans EC Inverter fans power abs. ESP std. Sound pressure level (3) 6000 7500 8000 13000 10000 13000 13500 18000 19000 24000 n° 1 1 1 2 2 2 2 3 3 4 4 kW 0,89 1,60 1,80 3,40 2,09 3,40 3,65 4,50 5,20 6,82 6,82 Pa 20 20 20 20 20 20 20 20 20 20 20 dB(A) 56 60 60 64 59 64 64 67 67 67 67 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 AIR FILTER Degree filtration HUMIDIFIER Capacity Power abs. kg/h 5 5 5 5 5 5 5 8 8 8 8 kW 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6 ELECTRICAL HEATERS Steps Power abs. 3 3 3 3 3 3 3 3 3 3 3 kW 9 9 9 15 15 15 15 18 18 18 18 21340 PLATE CONDENSER Water flow rate (1) l/h 4780 6190 7204 9650 3720x2 4805x2 6156x2 7370x2 8340x2 19160 Pressure drop (1) kPa 22 35 32 36 26 22 33 36 32 32 40 l 2,50 2,50 3 3,80 2x1,6 2x2,5 2x2,5 2x3 2x3,8 8,53 8,53 L mm 1000 1000 1000 1550 1550 1550 1550 2100 2100 2650 2650 P mm 790 790 790 790 790 790 790 790 790 790 790 H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 030m 039m 039m 052m 039m 052m 062m 078m 092m 103m 123m Water content DIMENSION COUPLING EXTERNAL UNIT BDC STD/LT/LN NOTE (1) Indoor air: 24°C/50% r.h.; Water: 30°-35°C (2) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C (3) Measured at 1,5 m high and 2m front unit, in open field conditions H P 271 L HPAC AF 20÷90 Versions STD base version MOD_A version with condensing fan speed regulation Features Unit for installing inside or outside the room to be air-conditioned Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. Standard G4 filtering section, F6-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. Capillary Pre and After sales service. Close control unit free-cooling source, water cooled direct expansion 20 - 100 kW Main accessories Unit Description Ductable close control units air-conditioners with capacity ranging from 20 to 100 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifer and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fittend with EC INVERTER fans, upflow or downflow. FREE-COOLING unit water cooled has to be connected with a remote dry cooler or an external chiller. Commands EVOLUTION Semi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm, Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 272 • • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board Electronic Thermostatic valve ACCURATE AF/STD Models 20 Electrical power supply 26 29 39 30 V-Ph~Hz 40 50 60 70 80 90 400/3+N/50 COOLING PERFORMANCES (DX) Total cooling capacity (1) kW 24,9 30,6 32,3 47,3 38,1 50 54,5 70,3 76,6 91,8 102 Sensible cooling capacity (1) kW 22,8 28,3 30 46,9 36,7 47,9 50,7 66,8 71,1 88,2 92,2 0,92 0,92 0,93 0,99 0,96 0,96 0,93 0,95 0,93 0,96 0,90 SHR COMPRESSORS Quantity n° 1 1 1 1 2 2 2 2 2 2 2 Power abs. kW 4,40 5,40 6,11 8 6,44 8,61 10,6 12,3 13,3 16 19,3 N° Circuits n° Refrigerant 1 1 1 1 2 2 2 2 2 2 2 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A COOLING PERFORMANCES (FC) Total cooling capacity (2) kW 20 24 25,1 40,8 33,6 41,5 43,8 56,6 58,1 76,7 78,3 Sensible cooling capacity (2) kW 20 24 25,1 40,8 33,6 41,5 43,8 56,6 58,1 76,7 78,3 1 1 1 1 1 1 1 1 1 1 1 l/h 4900 6330 7002 8430 7380 9810 11954 14360 16133 18120 20830 kPa 60 97 69 89 64 84 95 85 91 80 99 l 11,8 11,8 11,8 17,9 17 19,1 19,1 25,2 26,8 32,5 32,5 mc/h 24000 SHR Water flow rate Total water pressure drop PLATE CONDENSER Water content VENTILATION Air flow N° EC Inverter fans EC Inverter fans power abs. ESP std. Sound pressure level (3) 6000 7500 8000 13000 10000 13000 13500 18000 19000 24000 n° 1 1 1 2 2 2 2 3 3 4 4 kW 0,89 1,60 1,80 3,40 2,09 3,40 3,65 4,50 5,20 6,82 6,82 Pa 20 20 20 20 20 20 20 20 20 20 20 dB(A) 56 60 60 64 59 64 64 67 67 67 67 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 AIR FILTER Degree filtration HUMIDIFIER Capacity Power abs. kg/h 5 5 5 5 5 5 5 8 8 8 8 kW 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6 ELECTRICAL HEATERS Steps 3 3 3 3 3 3 3 3 3 3 3 kW 9 9 9 15 15 15 15 18 18 18 18 L mm 1000 1000 1000 1550 1550 1550 1550 2100 2100 2650 2650 P mm 790 790 790 790 790 790 790 790 790 790 790 H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 030m 039m 039m 052m 039m 052m 062m 078m 092m 103m 123m Power abs. DIMENSION COUPLING EXTERNAL UNIT BDC STD/LT/LN NOTE (1) Indoor air: 24°C/50% r.h.; Water: 30°-35°C (2) Indoor air: 24°C/50% r.h.; Water IN: 10°C and water flow of DX mode (3) Measured at 1,5 m high and 2m front unit, in open field conditions H P 273 L HPAC AC 007÷221 Versions STD base version HT for High Density application Features Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material to limit noise levels. The reliability and functionality of the all parts are guaranteed by partners who are world leaders in their sector. Double-inlet centrifugal fan per standard installed, directly coupled and suspended on vibration-isolation mountings. The fans are of the forward-bladed type for maximum efficiency and low noise. Available as option, EC INVERTER fans with electronic commutation, Backward Curved Fan type to minimize energy consumption and noise emission. Standard G2/G4 filtering section, F6-F8 optional, to CEN-EN 779 with average degree of separation 90.1% ASHRAE. The filter is self-extinguishing. The microprocessor controls the mains functions of the conditioning unit, it also controls the operating alarms with the possibility of interfacing to supervisor and remote-servicing systems. Switchboard to IEC 204-1/EN60204-1 Capillary Pre and After sales service. Close control unit chilled water 8 - 225 kW Unit Description Main accessories Ductable close control air-conditioners with capacities ranging from 8 to 225 kW for vertical installation and cooling only, with optional heating by means of heating element or hot water, optional humidifier and dehumidifier for precise temperature and humidity control.Particularly suitable for air-conditioning technological, server and CED rooms and all technological applications in general. Units fitted with centrifugal fans with upward airflow from the top or from the bottom. These units are provided with 3way valve and servomotor. Unit has to be connected with an external chiller. • • • • • • • • Commands EVOLUTION Semi-graphic display 132 x 64 pixel Programmable software, Record storage of 100 alarms, General alarm Automatic reset after blackout, Integral LAN system Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 274 Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board ACCURATE AC/STD Models Electrical power supply COOLING PERFORMANCES Total cooling capacity Sensible cooling capacity SHR Water flow rate Total unit pressure drop N° water circuits FANS Fan air flow N° Centrifugal fans N° EC Inverter fans Centrifugal fans power abs. EC Inverter fans power abs. ESP std. Sound pressure level AIR FILTER Degree filtration HUMIDIFIER Capacity Power absorbed ELECTRICAL HEATERS Steps Power absorbed DIMENSION L P H Models Electrical power supply COOLING PERFORMANCES Total cooling capacity Sensible cooling capacity SHR Water flow rate Total unit pressure drop N° water circuits FANS Fan air flow N° Centrifugal fans N° EC Inverter fans Centrifugal fans power abs. EC Inverter fans power abs. ESP std. Sound pressure level AIR FILTER Degree filtration HUMIDIFIER Capacity Power absorbed ELECTRICAL HEATERS Steps Power absorbed DIMENSION L P H 07 09 14 19 25 400/3+N/50 30 34 41 50 10,1 9,50 0,94 1660 36 1 15,7 15,7 1 2570 39 1 20,4 19 0,93 3330 60 1 28,4 28,4 1 4640 57 1 33,8 30,9 0,91 5520 65 1 37,4 37,4 1 6110 46 1 48,5 48,5 1 7930 69 1 57,7 52,8 0,92 9430 71 1 V-Ph~Hz (1) (1) kW kW (1) (1) l/h kPa n° 8,50 8,50 1 1390 33 1 m3/h n° n° kW kW Pa dB(A) 2500 1 1 0,49 0,27 20 50 2500 1 1 0,49 0,27 20 50 4900 2 2 1 0,53 20 53 4900 2 2 1 0,53 20 53 8000 1 1 2,02 1,69 20 60 8000 1 1 2,02 1,69 20 60 13500 2 2 3,61 3,51 20 64 13500 2 2 3,61 3,51 20 64 13500 2 2 3,61 3,51 20 64 G2 G2 G2 G2 G4 G4 G4 G4 G4 kg/h kW 3 2,25 3 2,25 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 n° kW 3 4 3 4 3 8 3 8 3 9 3 9 3 15 3 15 3 15 mm mm mm 600 500 1980 600 500 1980 1000 500 1980 1000 500 1980 1000 790 1980 1000 790 1980 1550 790 1980 1550 790 1980 1550 790 1980 060 070 080 090 131 400/3+N/50 151 171 191 221 82,6 73,7 0,89 13500 73 1 88,7 88,7 1 14500 69 1 104 97 0,93 17050 74 1 131 106 0,81 21650 122 1 155 127 0,82 25530 88 1 178 136 0,77 29290 105 1 197 156 0,79 32350 147 1 225 168 0,75 36610 135 1 (2) V-Ph~Hz (1) (1) kW kW (1) (1) l/h kPa n° 69 69 1 11280 71 1 m3/h n° n° kW kW Pa dB(A) 19000 2 3 6,55 5,11 20 67 19000 2 3 6,55 5,11 20 67 25000 3 4 9,42 6,82 20 67 25000 3 4 9,42 6,82 20 67 25000 3 4 9,42 6,82 20 67 30000 3 4,9 20 69 30000 3 4,9 20 69 36000 3 6,7 20 70 36000 3 6,7 20 70 G4 G4 G4 G4 G4 G4 G4 G4 G4 kg/h kW 8 6 8 6 8 6 8 6 8 6 10 7,50 10 7,5 15 11,3 15 11,3 n° kW 3 18 3 18 3 18 3 18 3 18 3 24 3 24 3 24 3 24 mm mm mm 2100 790 1980 2100 790 1980 2650 790 1980 2650 790 1980 2650 790 1980 2650 890 2180 2650 890 2180 3200 890 2180 3200 890 2180 (2) NOTE (1) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C (5) Measured at 1,5 m high and 2m front unit, in open field conditions 275 ACCURATE AC/HT Models Electrical power supply COOLING PERFORMANCES Total cooling capacity Sensible cooling capacity SHR Water flow rate Total unit pressure drop N° water circuits FANS Fan air flow N° Centrifugal fans N° EC Inverter fans Centrifugal fans power abs. EC Inverter fans power abs. ESP std. Sound pressure level AIR FILTER Degree filtration HUMIDIFIER Capacity Power absorbed ELECTRICAL HEATERS Steps Power absorbed DIMENSION L P H 025 030 034 041 050 400/3+N/50 060 070 080 090 37,1 37,1 1 6410 64 1 44,5 44,5 1 7654 51 1 52,2 52,2 1 9020 51 1 63,2 63,2 1 10920 76 1 73,3 73,3 1 12670 41 1 87,4 87,4 1 15100 46 1 97,4 97,4 1 16830 75 1 108 108 1 18660 80 1 V-Ph~Hz (1) (1) kW kW (1) (1) l/h kPa n° 30,8 30,8 1 5320 50 1 m3/h n° n° kW kW Pa dB(A) 8000 1 1 2,02 1,69 20 60 8000 1 1 2,02 1,69 20 60 13500 2 2 3,61 3,51 20 64 13500 2 2 3,61 3,51 20 64 13500 2 2 3,61 3,51 20 64 19000 2 3 6,55 5,11 20 67 19000 2 3 6,55 5,11 20 67 25000 3 4 9,42 6,82 20 67 25000 3 4 9,42 6,82 20 67 G4 G4 G4 G4 G4 G4 G4 G4 G4 kg/h kW 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 8 6 8 6 8 6 8 6 n° kW 3 9 3 9 3 15 3 15 3 15 3 18 3 18 3 18 3 18 mm mm mm 1000 790 1980 1000 790 1980 1550 790 1980 1550 790 1980 1550 790 1980 2100 790 1980 2100 790 1980 2650 790 1980 2650 790 1980 (2) NOTE (1) Indoor air: 33°C/40% r.h.; Water (in/out): 15/20°C (5) Measured at 1,5 m high and 2m front unit, in open field condition H P 276 L 277 HPAC AB 020÷140 Versions STD base version Features Unit for installing inside or outside the room to be air-conditioned Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability and functionality of the all parts are guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. Standard G4 filtering section, F6-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls the mains functions of the conditioning unit, it also controls the operating alarms with the possibility of interfacing to supervisor and remote-servicing systems. Electrical box under IEC 204-1/EN60204-1 rules. Capillary Pre and After sales service. DUAL COIL close control unit, chilled water type 20 - 145 kW Main accessories Unit Description Ductable close control units air-conditioners with capacity ranging from 20 to 145 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifer and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fittend with EC INVERTER fans, upflow or downflow. These units are provided with two indipendent chilled water circuits, each one with 3way valve and servomotor. Units has to be connected to 2 complete independent circuit each one in back-up to the other one. Commands EVOLUTION Semi-graphic display 132 x 64 pixel Programmable software, Record storage of 100 alarms, General alarm Automatic reset after blackout, Integral LAN system Standby management, Automatic rotation, Serious alarms, Operating contemporaneousness 278 • • • • • • • • Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board ACCURATE AB/STD Models 020 Electrical power supply 025 030 040 045 V-Ph~Hz 055 060 075 105 120 130 140 400/3+N/50 COOLING PERFORMANCES x each circuit Total cooling capacity (1) kW 22,5 29 41,2 50,5 54,2 66,4 76,6 94,3 105 125 131 148 Sensible cooling capacity (1) kW 22,5 27,7 41,2 47,5 54,2 64,5 76,6 89,9 102 112 128 137 1,00 0,96 1,00 0,94 1,00 0,97 1,00 0,95 0,98 0,90 0,98 0,92 Water flow rate (1) l/h 3670 4840 6740 8420 8860 11060 12520 15710 17420 20780 21880 24070 Total unit pressure drop (1) kPa 51 72 42 45 38 53 43 52 95 73 55 66 m3/h SHR FANS Fan air flow 8000 8000 13500 13500 19000 19000 26000 26000 30000 30000 36000 36000 n° 1 1 2 2 3 3 4 4 3 3 3 3 EC Inverter fans power abs. kW 1,69 1,69 3,51 3,51 5,11 5,11 6,82 6,82 4,9 4,9 6,7 6,7 ESP std. Pa 20 20 20 20 20 20 20 20 20 20 20 20 dB(A) 60 60 64 64 67 67 67 67 69 69 70 70 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 N° EC Inverter fans Sound pressure level (2) AIR FILTER Degree filtration HUMIDIFIER Capacity kg/h 5 5 5 5 8 8 8 8 10 10 15 15 kW 3,75 3,75 3,75 3,75 6 6 6 6 7,50 7,50 11,3 11,3 n° 3 3 3 3 3 3 3 3 3 3 3 3 kW 9 9 15 15 18 18 18 18 24 24 24 24 L mm 1000 1000 1550 1550 2100 2100 2650 2650 2650 2650 3200 3200 P mm 790 790 790 790 790 790 790 790 890 890 890 890 H mm 1980 1980 1980 1980 1980 1980 1980 1980 2180 2180 2180 2180 Power absorbed ELECTRICAL HEATERS Steps Power absorbed DIMENSION NOTE (1) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C (2) Measured at 1,5 m high and 2m front unit, in open field conditions H P 279 L HPAC BRE 014m÷116b Versions STD LN LT base version low noise version low outdoor temperature version Features ELECTRIC FANS of an axial type, statically and dynamically balanced on two levels, with blades in an inoxidable material and external rotor motor suitable for adjusting the speed, all mounted on a metal supporting grid in conformity with safety regulations. The motors are to VDE 0530-12.84. The protection rating is IP54 to DIN40050. CONDENSING COIL: the combination of innovative corrugated fins with the use of smooth pipes on the exchanger ensures excellent heat transfer with a minimum amount of fluid. The heat exchangers consist of aluminium fins and copper pipes. REFRIGERANT CIRCUIT CONNECTIONS are arranged along one side of the unite and are to be welded for safe connection that prevents any fluid leak. Remote condenser with axial fans Main accessories Unit Description Remote condensers with axial-type fan(s) for outdoor installation. Installation may be vertical with a horizontal air outflow or, using special brackets, horizontal with an upward air outflow. The very low noise, adjustable-speed fans are excellent for use in both technological and civil applications. BRC-BRE units operate with a singlephase 230/1/50 power supply totally independent and separate from the indoor unit ACCURATE. These condensing units are therefore also suited for use without being directly connected to indoor units. BRC-BRE units are not provided with integrated fans speed regulator per standard. However, CLIMAVENETA can provide such fans speed regulator as OPTIONAL, by installing it directly inside the indoor unit ACCURATE. 280 • • • • Legs kit for vertical air flow installation Epoxy coated (for fins only) Cataphoresys coil treatment Copper-Copper coil BRE / STD Models 014m 022m 027m 044m 051m 054b 065b 076b 100b 116b kW 13,4 21,7 26,6 43,5 50,4 53,3 65,1 kW 0,27 0,60 0,60 1,20 1,20 1,20 1,80 76,2 100 116 1,80 2,40 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 3 230/1/50 230/1/50 230/1/50 230/1/50 72 85 102 137 153 167 191 213 302 339 m3/h 5000 8200 7200 16400 dB(A) 40 46 46 49 15200 14400 24600 22800 28800 38000 49 49 51 51 52 53 5360 NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1240 1360 1360 2360 2360 2360 3360 3360 4360 P mm 494 580 580 580 580 580 580 580 580 580 H mm 764 1070 1070 1070 1070 1070 1070 1070 1070 1070 022m 027m 044m 051m 054b 065b 076b 100b 116b NOTE (1) Ext. air 35°C; 6T = 13°K (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow BRE / LN Models 014m NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 14,1 20 28,2 42,3 50 55,3 73,1 75,5 99,1 118 kW 0,33 0,26 0,66 0,99 0,99 0,99 1,32 1,32 1,65 2,52 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 85 125 137 191 213 235 276 302 339 397 m3/h 6000 6500 12000 18000 16500 16000 22000 20300 27050 28560 dB(A) 37 35 39 41 41 41 42 42 43 43 5560 V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1360 2120 2360 3360 3360 3360 4360 4360 5360 P mm 580 494 580 580 580 580 580 580 580 615 H mm 1070 764 1070 1070 1070 1070 1070 1070 1070 1070 014m 022m 027m 044m 051m 054b 065b 076b 100b 116b kW 13,4 21,7 26,6 43,5 50,4 53,3 65,1 76,2 100 116 kW 0,27 0,60 0,60 1,20 1,20 1,20 1,80 1,80 2,40 3 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 72 85 102 137 153 167 191 213 302 339 m3/h 5000 8200 7200 16400 15200 14400 24600 22800 28800 38000 dB(A) 40 46 46 49 49 49 51 51 52 53 5360 NOTE (1) Ext. air 35°C; 6T = 13°K (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow BRE / LT Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1240 1360 1360 2360 2360 2360 3360 3360 4360 P mm 494 580 580 580 580 580 580 580 580 580 H mm 764 1070 1070 1070 1070 1070 1070 1070 1070 1070 NOTE (1) Ext. air 35°C; 6T = 13°K (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow L H P 281 HPAC BRC 014m÷120b Versions STD LN LT base version low noise version low outdoor temperature version Features HOUSING: designed to allowed easy access to internal components, is made from prepainted galvanized sheet steel, and it: • offers hight corrosion strenght and impact resistence; • is resistant at low temperatures; • is non toxic; • does not produce polluting debris; • is completely covered in a protective plastic film. ELECTRIC FANS of an axial type, statically and dynamically balanced on two levels, with blades in an inoxidable material and external rotor motor suitable for adjusting the speed, all mounted on a metal supporting grid in conformity with safety regulations. The motors are to VDE 0530-12.84. The protection rating is IP54 to DIN40050. CONDENSING COIL: the combination of innovative corrugated fins with the use of smooth pipes on the exchanger ensures excellent heat transfer with a minimum amount of fluid. The heat exchangers consist of aluminium fins and copper pipes. Remote condenser with axial fans Unit Description Remote condensers with axial-type fan(s) for outdoor installation. Installation may be vertical with a horizontal air outflow or, using special brackets, horizontal with an upward air outflow. The very low noise, adjustable-speed fans are excellent for use in both technological and civil applications. BRC-BRE units operate with a singlephase 230/1/50 power supply totally independent and separate from the indoor unit ACCURATE. These condensing units are therefore also suited for use without being directly connected to indoor units. BRC-BRE units are not provided with integrated fans speed regulator per standard. However, CLIMAVENETA can provide such fans speed regulator as OPTIONAL, by installing it directly inside the indoor unit ACCURATE. REFRIGERANT CIRCUIT CONNECTIONS are arranged along one side of the unite and are to be welded for safe connection that prevents any fluid leak. ISOLATING SWITCH, contained in an electric box with protection rating IP54, with switch control accessible from the outside and connecting terminals. Main accessories • • • • 282 Legs kit for vertical air flow installation Epoxy coated (for fins only) Cataphoresys coil treatment Copper-Copper coil BRC / STD Models 014m 025m 032m 051b 052m 077b 088b 093b 102b 120b NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 14 26 32 52 52 77 90 93 102 120 kW 0,28 0,60 0,60 1,20 1,20 1,80 1,80 1,80 2,40 2,40 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 45 90 110 167 167 239 253 293 320 337 m3/h 4410 8780 7870 17560 17560 26340 25230 23610 35120 33640 dB(A) 41 48 48 51 51 53 53 53 54 54 4625 V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1175 1325 1325 2425 2425 3525 3525 3525 4625 P mm 510 630 630 630 630 630 630 630 630 630 H mm 872 1168 1168 1168 1168 1168 1168 1168 1168 1168 025m 032m 051b 052m 077b 088b 093b 102b 120b NOTE (1) Ext. air 35°C; 6T = 15°K (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow BRC / LN Models 014m NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 13 22 42 48 48 72 76 85 95 101 kW 0,13 0,33 0,66 0,66 0,66 0,99 0,99 1,32 1,32 1,32 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 50 90 110 177 177 253 293 320 337 391 m3/h 2930 6410 12820 12160 12160 18240 17340 25640 24320 23400 dB(A) 33 38 41 41 41 43 43 44 44 44 4625 V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1175 1325 2425 2425 2425 3525 3525 4625 4625 P mm 510 630 630 630 630 630 630 630 630 630 H mm 872 1168 1168 1168 1168 1168 1168 1168 1168 1168 025m 032m 051b 052m 077b 088b 093b 102b 120b NOTE (1) Ext. air 35°C; 6T = 15°K (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow BRC / LT Models 014m NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 14 26 32 52 52 77 90 93 102 120 kW 0,28 0,60 0,60 1,20 1,20 1,80 1,80 1,80 2,40 2,40 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 45 90 110 167 167 239 253 293 320 337 m3/h 4410 8780 7870 17560 17560 26340 25230 23610 35120 33640 dB(A) 41 48 48 51 51 53 53 53 54 54 4625 V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1175 1325 1325 2425 2425 3525 3525 3525 4625 P mm 510 630 630 630 630 630 630 630 630 630 H mm 872 1168 1168 1168 1168 1168 1168 1168 1168 1168 NOTE (1) Ext. air 35°C; 6T = 15°K (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow L H P 283 HPAC ARCC M1D÷M4F_B Versions STD base version Features CONDENSING COIL with high efficiency made by innovative corrugated fins and copper pipes with grooved internal surface. FANS with double-inlet, with vibration-isolation mountings, with protection rating IP44 and insulation class F. Main accessories • Legs kit for vertical air flow installation • Copper-Copper coil Remote condenser with centrifugal fans Unit Description Condensing unit with centrifugal fan with very low noise level are excellent for use in both technological and civil applications, designed for ductable installation with max ESP 150Pa. The possibility to remove the side panel made easier the cleaning operation and the air flow configuration. The ARCC units operate with a 230V/1/50Hz and 400V/3+N/50Hz power supply totally independent and separate from the indoor unit ACCURATE. These units are therefore also suited for use without being directly connected to indoor units. 284 ARCC / STD Models M1D M2B M2C M2D M3C M3D M2E NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 14 18 22 28 33 42 55 kW 0,525 1,1 1,05 1,50 1,575 1,575 2,76 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3+N/50 87 83 121 135 162 183 188 V-Ph~Hz Net weight kg VENTILATION Air flow (2) m3/h 3230 4560 7040 6460 10560 9690 13120 Sound pressure level (3) dB(A) 35 38 37 37 39 39 46 DIMENSION (4) L mm 760 1020 1360 1360 1960 1960 2060 P mm 950 800 845 845 845 845 845 H mm 845 520 950 950 950 950 950 M3D_B M2E_B M3G_B M3E_B M3F_B M4E_B M4F_B Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 42 55 66 82,5 87 110 116 kW 1,575 2,76 4,14 4,14 4,14 5,52 5,52 V-Ph~Hz Net weight 230/1/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 kg 183 188 216 266 293 344 378 VENTILATION Air flow (2) m3/h 9690 13120 17490 19680 18570 26240 24760 Sound pressure level (3) dB(A) 39 46 48 48 48 49 49 DIMENSION (4) 3960 L mm 1960 2060 1960 3010 3010 3960 P mm 845 845 845 845 845 845 845 H mm 950 950 950 950 950 950 950 NOTE (1) Ext. Air 35°C; 6T =15°K (2) ESP=100Pa (3) Sound pressure measured at 10 m in open field conditions (4) Without legs kit configuration; horizontal air flow H L P 285 HPAC BDC 013m÷123m Versions STD LN LT base version low noise version low outdoor temperature version Features HOUSING: designed to allowed easy access to internal components, is made from prepainted galvanized sheet steel, and it: • offers hight corrosion strenght and impact resistence; • is resistant at low temperatures; • is non toxic; • does not produce polluting debris; • is completely covered in a protective plastic film. ELECTRIC FANS of an axial type, statically and dynamically balanced on two levels, with blades in an inoxidable material and external rotor motor suitable for adjusting the speed, all mounted on a metal supporting grid in conformity with safety regulations. The motors are to VDE 0530-12.84. The protection rating is IP54 to DIN40050. HEAT EXCHANGER: the combination of innovative corrugated fins with the use of smooth pipes on the exchanger ensures excellent heat transfer with a minimum amount of fluid. The heat exchangers consist of aluminium fins and copper pipes. Dry Cooler Unit Description Dry Cooler with axial-type fan(s) for outdoor installation. Installation may be vertical with a horizontal air outflow or, using special brackets, horizontal with an upward air outflow. The very low noise, adjustable-speed fans are excellent for use in both technological and civil applications. BDC units operate with a single-phase 230/1/50 power supply totally independent and separate from the indoor unit ACCURATE. These units are therefore also suited for use without being directly connected to indoor units. BDC units are not provided with integrated fans speed regulator per standard. However, CLIMAVENETA can provide such fans speed regulator as OPTIONAL, by installing it directly inside the indoor unit ACCURATE. HYDRAULICS CIRCUIT CONNECTIONS are arranged along one side of the unite and are to be welded for safe connection that prevents any fluid leak. ISOLATING SWITCH, contained in an electric box with protection rating IP54, with switch control accessible from the outside and connecting terminals. Main accessories • • • • 286 Legs kit for vertical air flow installation Epoxy coated (for fins only) Cataphoresys coil treatment Copper-Copper coil BDC / STD Models 013m 030m 039m 052m 062m 078m 092m 103m 123m NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 17 33 40,5 61 68 83 98,5 121 135 kW 0,60 1,20 1,20 1,80 1,80 2,40 3,60 3,60 3,60 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 90 167 177 253 293 337 490 519 601 m3/h 8780 17560 16820 25230 23610 33640 52680 50460 47220 dB(A) 48 51 51 53 53 54 56 56 56 3658 V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1325 2425 2425 3525 3525 4625 3658 3658 P mm 630 630 630 630 630 630 760 760 760 H mm 1168 1168 1168 1168 1168 1168 2286 2286 2286 030m 039m 052m 062m 078m 092m 103m 123m NOTE (1) Water temp.: 35/30°C; Ext. Temp.: 24°C (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow BDC / LN Models 013m NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input Electrical power supply kW 14 32 40,5 54 65,5 82 96 107 129 kW 0,33 0,66 0,99 1,32 1,32 1,65 1,98 2,64 2,64 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 90 177 239 320 337 363 519 640 675 m3/h 6410 12160 19230 25640 24320 30400 36480 51280 48640 dB(A) 38 41 43 44 44 45 46 47 47 4758 V-Ph~Hz Net weight kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1325 2425 3525 4625 4625 5725 3658 4758 P mm 630 630 630 630 630 630 760 760 760 H mm 1168 1168 1168 1168 1168 1168 2286 2286 2286 013m 030m 039m 052m 062m 078m 092m 103m 123m 17 33 40,5 61 68 83 98,5 121 135 NOTE (1) Water temp.: 35/30°C; Ext. Temp.: 24°C (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow BDC / LT Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input kW kW Electrical power supply V-Ph~Hz Net weight 0,601,20 1,20 1,80 1,80 2,40 3,60 3,60 3,60 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 90 167 177 253 293 337 490 519 601 m3/h 8780 17560 16820 25230 23610 33640 52680 50460 47220 dB(A) 48 51 51 53 53 54 56 56 56 3658 kg VENTILATION Air flow Sound pressure level (2) DIMENSION (3) L mm 1325 2425 2425 3525 3525 4625 3658 3658 P mm 630 630 630 630 630 630 760 760 760 H mm 1168 1168 1168 1168 1168 1168 2286 2286 2286 NOTE (1) Water temp.: 35/30°C; Ext. Temp.: 24°C (2) Sound pressure measured at 10 m in open field conditions (3) Without legs kit configuration; horizontal air flow L H P 287 ACKA A ACK KA A 288 AGED packaged packaged 289 Packaged WORK 0101÷0602 Versions B base version Configurations B AX CE base function function with exhaust air axial fan function with return air centrifugal fan Features Reversible rooftop unit, for medium crowding applications 37,4 - 198 kW Unit Description Unit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, prepainted panelling with internal thermic insulating and soundproofing material, top frame made with Alloy, basement made from hot-galvanised, centrifugal supply fan section, free-cooling, Exhaust Air thermodynamic effect. Efficiency, Plug&Play approach, an intuitive and comprehensive electronic controller are the leading features of this unit. It is designed to obtain extreme compactness, simplified on-site installations and maintainance and a reduction in their associated costs. All the same, it is guaranteed the best air treatment quality, thanks to the R-410A refrigerant use, the Exhaust Air thermodynamic effect and the optional high efficiency filters. Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 290 REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). COMFORT The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. Main accessories UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊCO2 control sensor for air quality UÊHot gas post heating UÊRemote keyboard (distance to 200m and to 500m) UÊSet-up for remote connectivity with ModBus/Echelon protocol cards THERMODYNAMIC SCROLL AXIAL CENTRIFUGAL r HFC R-410A FREE COOLING COOLING HEATING WORK / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) HEATING ONLY Heating capacity (2) Compressors power input (2) OUTLET FANS Supply air flow rate Useful static head (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) SIZE A (5) B (5) H (5) Operating weight (5) 0101 0121 0152 0182 0202 0252 0302 0352 0402 0452 0502 0552 0602 kW kW kW 37,4 27,9 7,70 45,9 33,5 10,5 53,2 38,3 13,1 60,3 44,2 16,1 70,4 51,2 17,5 86,4 63,3 23,3 100 72,3 27,2 115 84,3 32 132 97 35,3 143 105 40,6 166 122 44,7 182 132 49,5 198 144 54,7 kW kW 35,7 7 44,4 9,20 50,3 10,2 56,9 12,4 66 13,5 83,8 18,1 91,4 19,3 108 23,8 127 28,2 138 31,7 156 32,1 175 37,5 194 42,4 m3/h Pa kW 6000 250 1,57 8000 250 2,49 9000 250 3,18 10000 250 3,97 11500 250 2,96 15000 250 5,46 17000 250 5,68 20000 250 7,90 23000 250 6,90 25500 250 8,31 29500 250 10,9 30500 250 11,8 33000 250 14,2 N. 1/1 1/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 82 83 86 87 87 87 88 89 90 91 91 91 92 2175 2250 2410 1050 2175 2250 2410 1060 2175 2250 2410 1110 2175 2250 2410 1130 3145 2250 2410 1530 3145 2250 2410 1550 3145 2250 2410 1600 3145 2250 2410 1660 4600 2250 2410 2360 4600 2250 2410 2370 4600 2250 2410 2380 4600 2250 2410 2440 4600 2250 2410 2470 dB(A) mm mm mm kg Note: 1 Cooling: Outdoor 35°C 50% R.H. / Indoor 26°C 52% R.H. / Mix 30% 2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 30% 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0101-0602 Switchboard side Condensation coil side mm mm 1500 2000 291 Packaged WORK-T 0101÷0602 Versions B base version Configurations B AX CE base function function with exhaust air axial fan function with return air centrifugal fan Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). COMFORT The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. Cooling only rooftop unit, for medium crowding applications 34,7 - 200 kW Main accessories Unit Description Unit for outdoor installation, cooling-only and direct expansion for the air conditioning, with scroll compressors running on R410A, prepainted panelling with internal thermic insulating and soundproofing material, top frame made with Alloy, basement made from hot-galvanised, centrifugal supply fan section, free-cooling, Exhaust Air thermodynamic effect. Efficiency, Plug&Play approach, an intuitive and comprehensive electronic controller are the leading features of this unit. It is designed to obtain extreme compactness, simplified on-site installations and maintainance and a reduction in their associated costs. All the same, it is guaranteed the best air treatment quality, thanks to the R-410A refrigerant use, the exhaust air thermodynamic effect and the optional high efficiency filters. Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 292 UÊEnthalpy free-cooling UÊCO2 control sensor for air quality UÊHot gas post heating UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊHigh efficiency filters: electronic or rigid pocket F7 THERMODYNAMIC SCROLL AXIAL CENTRIFUGAL r HFC R-410A FREE COOLING COOLING WORK-T / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) OUTLET FANS Supply air flow rate Available static pressure (2) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) SIZE A (4) B (4) H (4) Operating weight (4) 0101 0121 0152 0182 0202 0252 0302 0352 0402 0452 0502 0552 0602 kW kW kW 34,7 25,9 9 43,1 32,9 11,8 51,7 37,4 13,8 60,5 44,2 16 70,6 51,2 17,4 86,6 63,3 23,2 100 72,3 27 115 84,3 31,9 133 96,2 35,1 143 105 40,4 167 122 44,5 182 132 49,3 200 145 53,9 m3/h Pa kW 6000 250 1,57 8000 250 2,49 9000 250 3,18 10000 250 3,97 11500 250 1,48 15000 250 2,73 17000 250 2,84 20000 250 3,95 23000 250 2,30 25500 250 2,77 29500 250 3,63 30500 250 3,94 33000 250 4,73 N. 1/1 1/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 82 83 86 87 87 87 88 89 90 91 91 91 92 1175 2250 2410 1050 1175 2250 2410 1060 1175 2250 2410 1110 1175 2250 2410 1130 3145 2250 2410 1530 3145 2250 2410 1550 3145 2250 2410 1600 3145 2250 2410 1660 4600 2250 2410 2360 4600 2250 2410 2370 4600 2250 2410 2380 4600 2250 2410 2440 4600 2250 2410 2470 dB(A) mm mm mm kg Note: 1 Cooling: Outdoor 35°C 50% R.H. / Indoor 26°C 52% R.H. / Mix 30% 2 ESP for standard configuration (optional accessories not included/calculated) 3 Sound power on the basis of measurements made in compliance with ISO 3744. 4 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0101-0602 Switchboard side Condensation coil side mm mm 1500 2000 293 Packaged WHISPER 0102÷0604 Versions B base version Features VARIABLE AIRFLOW FOR AIR TREATMENT SECTION The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. HIGH ENERGY EFFICIENCY The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation. PLUG-FAN VENTILATION The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit. SAFE USE The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. High efficiency reversible rooftop unit, for medium crowding applications 35,7 - 197 kW Unit Description Autonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plugfans and direct expansion finned internal exchangers. Management of air treatment section according to the requested heating or cooling capacity by the Vair function. Commands AIR3000SE The AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units. 294 Main accessories UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) THERMODYNAMIC SCROLL AXIAL PLUG FAN r HFC R-410A FREE COOLING COOLING HEATING WHISPER / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) HEATING ONLY Heating capacity (2) Compressors power input (2) OUTLET FANS Supply air flow rate Useful static head (3) Power Input SUCTION FANS/BLOWERS Nominal air flow Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) SIZE A B H Operating weight 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 0454 0504 0604 kW kW kW 35,7 27,2 8,70 45 34,5 11,9 52,3 38,3 13,6 60,7 46,4 16,5 73,1 55,7 17,2 94,5 69,5 22,3 103 75,5 26,4 122 93,5 31,9 125 92,1 33,7 139 102 37,4 153 117 41,1 182 132 44,7 197 145 53 kW kW 31,9 6,70 42,9 9,20 49,6 10,1 57,5 12,1 64,9 12,8 87,3 16,5 94,7 19,2 113 21,8 115 22,7 130 25,3 140 31,1 172 34,5 186 40,7 m3/h Pa kW 6500 250 1,34 7800 250 1,72 8600 250 1,96 10500 250 2,78 13000 250 2,36 15500 250 3,20 17500 250 4,04 21000 250 4,44 21000 250 4,44 23500 250 5,44 27000 250 5,28 29000 250 6,10 32000 250 7,70 m3/h Pa kW 6500 150 1,30 7800 150 1,24 8600 150 1,16 10500 150 1,66 13000 150 1,58 15500 150 1,68 17500 150 2,06 21000 150 2,02 21000 150 2,02 23500 150 2,46 27000 150 3 29000 150 3,54 32000 150 4,48 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 4/2 4/2 4/2 88 89 90 91 94 95 95 96 95 97 97 97 98 4350 1700 1630 1290 4350 1700 1630 1320 4350 1700 1630 1380 4350 1700 1630 1400 4500 2250 2390 2170 4500 2250 2390 2230 4500 2250 2390 2280 5295 2250 2390 2750 5295 2250 2390 2860 5295 2250 2390 2880 6500 2250 2390 3360 6500 2250 2390 3450 6500 2250 2390 3500 dB(A) mm mm mm kg Note: 1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30% 2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 30% 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. Minimum clearance required 0102-0604 Switchboard side Condensation coil side mm mm 1500 2000 H A B 295 Packaged WHISPER-T 0102÷0604 Versions B base version Features VARIABLE AIRFLOW FOR AIR TREATMENT SECTION The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. HIGH ENERGY EFFICIENCY The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation. PLUG-FAN VENTILATION The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit. SAFE USE The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. High efficiency cooling only rooftop unit, for medium crowding applications 35,8 - 197 kW Unit Description Autonomous rooftop unit, air/air cooling-only, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Management of air treatment section according to the requested heating or cooling capacity by the Vair function. Commands AIR3000SE The AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units. 296 Main accessories UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊHeating resource: hot water coil, electrical heater, burner methane gas UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) THERMODYNAMIC SCROLL AXIAL PLUG FAN r HFC R-410A FREE COOLING COOLING WHISPER-T / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) OUTLET FANS Supply air flow rate Available static pressure (2) Power Input (3) SUCTION FANS/BLOWERS Nominal air flow Useful static head (2) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) SIZE A B H Operating weight 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 0454 0504 0604 kW kW kW 35,8 27,6 8,60 44,6 33,7 12,2 52,2 38,3 13,6 60,6 45,7 16,6 71,9 55,7 17,4 94,8 69 22,2 103 77,3 26,3 123 92,1 31,3 126 92,8 33,1 139 101 37,4 154 116 40,7 182 131 44,4 197 144 52,7 m3/h Pa kW 6500 250 1,34 7800 250 1,72 8600 250 1,96 10500 250 2,78 13000 250 2,36 15500 250 3,20 17500 250 4,04 21000 250 4,44 21000 250 4,44 23000 250 5,44 27000 250 5,28 29000 250 6,10 32000 250 7,70 m3/h Pa kW 6500 150 1,30 7800 150 1,24 8600 150 1,16 10500 150 1,66 13000 150 1,58 15500 150 1,68 17500 150 2,06 21000 150 2,02 21000 150 2,02 23500 150 2,46 27000 150 3 29000 150 3,54 32000 150 4,48 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 4/2 4/2 4/2 88 89 90 91 94 95 95 96 95 97 97 97 98 4350 1700 1630 1290 4350 1700 1630 1320 4350 1700 1630 1380 4350 1700 1630 1400 4500 2250 2390 2170 4500 2250 2390 2230 4500 2250 2390 2280 5295 2250 2390 2750 5295 2250 2390 2860 5295 2250 2390 2880 6500 2250 2390 3360 6500 2250 2390 3450 6500 2250 2390 3500 dB(A) mm mm mm kg Note: 1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30% 2 ESP for standard configuration (optional accessories not included/calculated) 3 Sound power on the basis of measurements made in compliance with ISO 3744. Minimum clearance required 0102-0604 Switchboard side Condensation coil side mm mm 1500 2000 H A B 297 Packaged i-WHISPER ENTHALPY 0182÷0753 Versions B base version Features High efficiency reversible rooftop unit, with enthalpy recovery for medium crowding applications 87,0 - 338 kW VARIABLE AIRFLOW FOR AIR TREATMENT SECTION The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. THERMOHYGROMETRIC MANAGEMENT ON THE SUPPLY AIRFLOW The thermohygrometric management on the supply airflow is the best way to maintain the requested indoor temperature and relative humidity, even for high fresh airflow rate. EXTREME ADAPTABILITY TO THE REQUESTED LOAD The cooling/heating capacity provided is perfectly adapted to the load of the room to be served, thanks to the advantages of Inverter technology for compressors. This ensures excellent conditions of well-being. WIDE RANGE OF AIRFLOW MIX/PRECISION ON INDOOR CONDITIONS This unit is perfect for air conditioning of a wide range of architectural construction types (fresh airflow up to 80%) in which indoor air conditions are the most important thing, moreover precise regulation on supply and indoor conditions is requested. ROTARY-TYPE ENTHALPY RECOVERY The exclusive rotary-type enthalpy recovery allows to get high running capacity guarantying a lower introduction of moisture in the summer operation of the unit. Unit Description Main accessories Autonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with variable speed and refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air, axial fans and condensation control device. Enthalpic Freecooling. Post-heating gas coil. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function. UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) Commands AIR3000SE The AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The heat adjustment feature offers sophistcated capacity management wth proportional compressor modulation that can be based on the temperature of the delivery air. This allows accurate temperature adjustment and maximum comfort, partly thanks to the special integration with post-heating. Functions include adjustment of available resources, ambient humidity and enthalpic free-cooling. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units. 298 THERMODYNAMIC ROTARY SCROLL PLUG FAN r HFC R-410A FREE COOLING HEATING COOLING i-WHISPER ENTHALPY / B Models COOLING ONLY Cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) OUTLET FANS Supply air flow rate Useful static head (3) Power Input SUCTION FANS/BLOWERS Nominal air flow Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) SIZE A B H Operating weight 0182 0202 0262 0302 0352 0402 0553 0653 0753 kW kW 87 19 113 20 134 26 150 27 166 34 200 40 242 55 294 63 338 73 kW kW 86 16 104 18 124 21 136 23 159 28 190 34 248 45 293 54 335 61 m3/h Pa kW 7200 810 3,50 9000 780 3,60 11000 705 5,30 12500 785 6 13500 765 6,30 16500 790 8,50 20000 805 10,8 24000 830 12,6 30000 840 16,1 m3/h Pa kW 7200 600 2,70 9000 600 3 11000 530 3,50 12500 600 4,60 13500 600 5 16500 600 7,50 20000 600 7,10 24000 600 9,50 30000 600 12,3 N. 2/2 2/2 2/2 2/2 2/2 2/2 3/2 3/2 3/2 dB(A) 92 94 94 94 95 96 97 97 98 4350 1700 1630 * 4500 2250 2390 * 4500 2250 2390 * 4500 2250 2390 * 4500 2250 2390 * 5300 2250 2390 * 6500 2250 2390 * 6500 2250 2390 * 6500 2250 2390 * mm mm mm kg Note: 1 Cooling: Outdoor 35°C 50% R.H. / Indoor 26°C 50% R.H. / Mix 80% 2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 80% 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. Minimum clearance required 0182-0753 Switchboard side Condensation coil side mm mm 1500 2000 H A B 299 Packaged WHISPER ENTHALPY 0102÷0604 Versions B base version Features High efficiency reversible rooftop unit, with enthalpy recovery for medium crowding applications 47,4 - 243 kW Unit Description Autonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function. Commands AIR3000SE The AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units. 300 VARIABLE AIRFLOW FOR AIR TREATMENT SECTION The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. HIGH ENERGY EFFICIENCY The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation. ROTARY-TYPE ENTHALPY RECOVERY The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values. PLUG-FAN VENTILATION The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit. SAFE USE The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. Main accessories UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) THERMODYNAMIC ROTARY SCROLL AXIAL PLUG FAN r HFC R-410A FREE COOLING COOLING HEATING WHISPER ENTHALPY / B Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) OUTLET FANS Supply air flow rate Useful static head (3) Power Input SUCTION FANS/BLOWERS Nominal air flow Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) SIZE A B H Operating weight 0102 0122 0152 0182 0202 kW 47,4 58,3 66,6 77,5 96,7 kW 31,3 38 43,6 52,2 64,2 kW 8,60 11,7 13,4 16,2 16,9 kW kW 40,8 7,20 53,3 9,90 60,7 10,8 70,7 12,8 m3/h Pa kW 6500 250 1,50 7800 250 1,96 8600 250 2,24 m3/h Pa kW 6500 150 1,04 7800 150 1,62 N. 2/2 dB(A) mm mm mm kg 0302 0352 0364 0404 0454 0504 0604 122 133 157 160 176 195 225 243 79,1 87,6 105 107 118 133 149 163 21,9 26 31,4 33 36,9 40,5 44 52,2 83,2 13,7 108 17,6 118 20,6 140 23,2 143 24,2 159 26,9 173 33,2 207 36,8 224 43,2 10500 250 3,18 13000 250 2,74 15500 250 3,68 17500 250 4,66 21000 250 5,22 21000 250 5,22 23500 250 6,38 27000 250 7,84 29000 250 9,06 32000 250 11,3 8600 150 1,92 10500 150 2,82 13000 150 2 15500 150 2,68 17500 150 3,98 21000 150 3,66 21000 150 3,66 23500 150 4,50 27000 150 4,42 29000 150 5,16 32000 150 6,82 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 4/2 4/2 4/2 88 89 90 91 94 95 95 96 95 97 97 97 98 4350 1700 1630 1430 4350 1700 1630 1460 4350 1700 1630 1520 4350 1700 1630 1540 4500 2250 2390 2430 4500 2250 2390 2480 4500 2250 2390 2540 5295 2250 2390 3000 5295 2250 2390 3110 5295 2250 2390 3130 6500 2250 2390 3620 6500 2250 2390 3710 6500 2250 2390 3760 Note: 1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30% 2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 30% 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. Minimum clearance required 0102-0604 Switchboard side Condensation coil side mm mm 1500 2000 H A B 301 0252 Packaged WHISPER ENTHALPY-T 0102÷0604 Versions B base version Features High efficiency cooling only rooftop unit, with enthalpy recovery for medium crowding applications 47,4 - 243 kW Unit Description Autonomous rooftop unit, air/air cooling-only, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function. Commands AIR3000SE The AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units. 302 VARIABLE AIRFLOW FOR AIR TREATMENT SECTION The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. HIGH ENERGY EFFICIENCY The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation. ROTARY-TYPE ENTHALPY RECOVERY The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values. PLUG-FAN VENTILATION The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit. SAFE USE The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. Main accessories UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊHeating resource: hot water coil, electrical heater, burner methane gas UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) THERMODYNAMIC ROTARY SCROLL AXIAL PLUG FAN r HFC R-410A FREE COOLING COOLING WHISPER ENTHALPY-T / B Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) OUTLET FANS Supply air flow rate Useful static head (2) Power Input SUCTION FANS/BLOWERS Nominal air flow Available static pressure (2) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) SIZE A B H Operating weight 0102 0122 0152 0182 0202 kW 47,4 58,4 66,5 77,5 kW 31,3 38 43,6 52,2 kW 8,50 11,7 13,3 m3/h Pa kW 6500 250 1,50 7800 250 1,96 m3/h Pa kW 6500 150 1,04 N. dB(A) mm mm mm kg 0252 0302 0352 0364 0404 0454 0504 0604 96,9 122 133 158 161 176 196 225 243 64,2 79,1 87 104 107 118 133 149 163 16,3 16,8 21,8 25,9 30,9 32,5 36,8 40,1 43,8 52 8600 250 2,24 10500 250 3,18 13000 250 2,74 15500 250 3,68 17500 250 4,66 21000 250 5,22 21000 250 5,22 23500 250 6,38 27000 250 7,84 29000 250 9,06 32000 250 11,3 7800 150 1,62 8600 150 1,92 10500 150 2,82 13000 150 2 15500 150 2,68 17500 150 3,98 21000 150 3,66 21000 150 3,66 23500 150 4,50 27000 150 4,42 29000 150 5,16 32000 150 6,82 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 4/2 4/2 4/2 88 89 90 91 94 95 95 96 95 97 97 97 98 4350 1700 1630 1430 4350 1700 1630 1460 4350 1700 1630 1520 4350 1700 1630 1540 4500 2250 2390 2430 4500 2250 2390 2480 4500 2250 2390 2540 5295 2250 2390 3000 5295 2250 2390 3110 5295 2250 2390 3130 6500 2250 2390 3620 6500 2250 2390 3710 6500 2250 2390 3760 Note: 1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30% 2 ESP for standard configuration (optional accessories not included/calculated) 3 Sound power on the basis of measurements made in compliance with ISO 3744. Minimum clearance required 0102-0604 Switchboard side Condensation coil side mm mm 1500 2000 H A B 303 Packaged WHISPER HALL 110÷400 Versions B base version Features High efficiency reversible rooftop unit, with enthalpy recovery for high crowding applications 45,9 - 146 kW VARIABLE AIRFLOW FOR AIR TREATMENT SECTION The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. HIGH ENERGY EFFICIENCY The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation. ROTARY-TYPE ENTHALPY RECOVERY The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values. PLUG-FAN VENTILATION The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit. COMFORT The wide working field, the air quality probe, the predisposition for the remote supervising and the accurate planning of the unit ensure optimum capacities and comfort warrantee, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric and crowding conditions. Unit Description Main accessories Autonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Air quality control with CO2 probe. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function. UÊHot gas post heating UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊSet-up for remote connectivity with Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) Commands AIR3000SE The AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units. 304 THERMODYNAMIC ROTARY SCROLL AXIAL PLUG FAN r HFC R-410A FREE COOLING HEATING COOLING WHISPER HALL / B Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) OUTLET FANS Supply air flow rate Useful static head (3) Power Input SUCTION FANS/BLOWERS Nominal air flow Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) SIZE A B H Operating weight 110 140 180 200 260 kW 45,9 55,7 kW 25,1 31,1 kW 7,60 kW kW 63,7 72 98,3 115 128 146 36,8 41,6 55,7 65,1 73,7 83,2 10,9 12,4 15 14,9 20,4 24,1 29 53,1 7,10 65,4 8,80 75,5 9,70 84,4 11,7 115 12,4 137 16,8 154 19,4 171 21,5 m3/h Pa kW 4300 260 1,28 5400 260 1,72 6800 260 2,42 7800 260 3,08 10000 260 3,08 11700 260 4,02 14000 260 5,64 15000 260 6,42 m3/h Pa kW 4300 150 1,22 5400 150 1,30 6800 150 1,48 7800 150 1,72 10000 150 1,58 11700 150 1,96 14000 150 3,04 15000 150 2,96 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 88 89 90 91 94 94 94 95 4350 1700 1630 1430 4350 1700 1630 1460 4350 1700 1630 1520 4350 1700 1630 1540 4500 2250 2390 2430 4500 2250 2390 2480 4500 2250 2390 2540 5295 2250 2390 3000 dB(A) mm mm mm kg Note: 1 Cooling: Outdoor 32°C 50% R.H. / Indoor 26°C 50% R.H. / Mix 75% 2 Heating: Outdoor -5°C 85% R.H. / Indoor 20°C 50% R.H. / Mix 75% 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. Minimum clearance required 110-400 Switchboard side Condensation coil side mm mm 1500 2000 305 300 360 400 Packaged WISDOM 0101÷1204 Versions B base version Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). COMFORT The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. FLEXIBILITY Climaveneta offers units with innumerable choices for the supply and return airflows directions. Reversible rooftop unit, for medium crowding applications 34,5 - 355 kW Unit Description Unit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The unit in standard execution can treat recirculating-only air; other available executions (optionals) are MIX (return air and fresh air mix), FCS (Standard Free-Cooling with supply fans) or FCC (Centrifugal Free-Cooling with supply and return fans). Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 306 Main accessories UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊRemote keyboard (distance to 200m and to 500m) SCROLL AXIAL CENTRIFUGAL r HFC R-410A FREE COOLING COOLING HEATING WISDOM / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) HEATING ONLY Heating capacity (2) Compressors power input (2) OUTLET FANS Supply air flow rate Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) 0101 0121 0151 0102 0122 0152 0182 0202 0252 0302 0352 kW kW kW 34,5 26,8 8,30 41,2 30,9 11,6 48,5 36,6 12,6 33,8 26,5 8,30 41,4 31 12,6 49,3 37,9 13 55 42,5 14,6 65,9 50,6 17,4 85,7 65,6 23 92,9 71,1 26,8 109 80,9 29,1 kW kW 33,2 7 43,2 9,90 47,6 10,5 32,2 6,80 44,1 10,6 48,7 10,7 53,1 11,4 63,4 14,1 83,8 18,3 90,9 21 109 24 m3/h Pa kW 6500 220 1,10 7800 219 1,50 8500 330 2,20 6500 220 1,10 7800 219 1,50 8600 315 2,20 10500 261 3 13000 208 2,20 15500 202 3 17500 269 4,40 21000 271 6 N. 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 78 63 78 63 78 63 78 63 78 63 78 63 78 63 84 68 84 68 84 68 87 71 2900 1780 1640 870 2900 1780 1640 910 2900 1780 1640 950 2900 1780 1640 870 2900 1780 1640 910 2900 1780 1640 980 2900 1780 1640 1010 3400 2330 1790 1210 3400 2330 1790 1290 3400 2330 1790 1350 3400 2330 1790 1450 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204 kW kW kW 113 86 27,9 128 96,8 35,4 153 116 39,9 168 125 44,8 189 142 52,5 213 159 61,2 258 196 68,5 278 211 78,4 316 238 84,8 335 245 93 355 253 105 kW kW 110 23 126 28,6 148 32,3 170 38,3 185 41,7 213 52,3 256 57,6 279 65,4 313 70,2 343 78,8 378 91,4 21000 271 6 23500 303 8 27000 215 6 29000 261 8 32000 333 11 45000 235 12 50000 255 16 54000 400 22 56000 290 30 56000 290 30 56000 290 30 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 87 71 87 71 93 76 93 76 93 76 * * * * * * * * * * * * 3900 2330 1820 1560 3900 2330 1820 1650 3900 2330 2380 1890 3900 2330 2380 2080 3900 2330 2380 2230 6580 2330 2350 3530 6580 2330 2350 3790 6580 2330 2350 3790 6580 2330 2350 3910 6580 2330 2350 4150 6580 2330 2350 4160 mm mm mm kg Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) HEATING ONLY Heating capacity (2) Compressors power input (2) OUTLET FANS Supply air flow rate Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A (6) B (6) H (6) Operating weight (6) m3/h Pa kW mm mm mm kg Note: 1 Cooling: Outdoor 34°C 50% R.H. Indoor 27°C 47% R.H. 2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. 5 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base. 6 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0101-1204 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1500 0 2000 H A B 307 Packaged WISDOM-T 0101÷1204 Versions B base version Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). COMFORT The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. FLEXIBILITY Climaveneta offers units with innumerable choices for the supply and return airflows directions. Main accessories Cooling only rooftop unit, for medium crowding applications 34,7 - 357 kW Unit Description Unit for outdoor installation, cooling-only and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The unit in standard execution can treat recirculating-only air; other available executions (optionals) are MIX (return air and fresh air mix), FCS (Standard Free-Cooling with supply fans) or FCC (Centrifugal Free-Cooling with supply and return fans). Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 308 UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊHeating resource: hot water coil, electrical heater, burner methane gas UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) SCROLL AXIAL CENTRIFUGAL r HFC R-410A FREE COOLING COOLING WISDOM-T / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) OUTLET FANS Supply air flow rate Available static pressure (2) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) 0101 0121 0151 0102 0122 0152 0182 0202 0252 0302 0352 kW kW kW 34,7 26,9 8,11 - 48,8 36,7 12,4 34,1 26,7 8,11 41,8 31,1 12,3 47,8 37,4 13,8 55,3 42,6 14,3 66,4 50,9 17,1 83,2 64,8 24,4 93,8 71,3 26,2 109 80,9 29,1 m3/h Pa kW 6500 220 1,10 - 8500 330 2,20 6500 220 1,10 7800 219 1,50 8600 315 2,20 10500 261 3,00 13000 208 2,20 15500 202 3,00 17500 269 4,40 21000 271 6,00 N. 1/1 - 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 78,0 63,0 - 78,0 63,0 78,0 63,0 78,0 63,0 78,0 63,0 78,0 63,0 84,0 68,0 84,0 68,0 84,0 68,0 87,0 71,0 mm mm mm kg 2900 1780 1640 870 - 2900 1780 1640 950 2900 1780 1640 870 2900 1780 1640 910 2900 1780 1640 980 2900 1780 1640 1010 3400 2330 1790 1210 3400 2330 1790 1290 3400 2330 1790 1350 3400 2330 1790 1450 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204 110 85,3 29,7 129 97,1 34,7 154 116 39,2 170 126 44,1 191 142 51,5 215 159 60,1 260 197 67,5 280 211 77,0 318 239 83,6 337 246 91,9 357 253 104 21000 271 6,00 23500 303 8,00 27000 215 6,00 29000 261 8,00 32000 333 11,0 45000 235 12,0 50000 255 16,0 54000 400 22,0 56000 290 30,0 56000 290 30,0 56000 290 30,0 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 87,0 71,0 87,0 71,0 93,0 76,0 93,0 76,0 93,0 76,0 * * * * * * * * * * * * mm mm mm kg 3900 2330 1820 1560 3900 2330 1820 1650 3900 2330 2380 1890 3900 2330 2380 2080 3900 2330 2380 2230 6580 2330 2350 3530 6580 2330 2350 3790 6580 2330 2350 3790 6580 2330 2350 3910 6580 2330 2350 4150 6580 2330 2350 4160 Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) OUTLET FANS Supply air flow rate Available static pressure (2) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A (5) B (5) H (5) Operating weight (5) kW kW kW m3/h Pa kW Note: 1 Cooling: Outdoor 34°C 50% R.H. Indoor 27°C 47% R.H. 2 ESP for standard configuration (optional accessories not included/calculated) 3 Sound power on the basis of measurements made in compliance with ISO 3744. 4 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base. 5 Unit in standard configuration/execution, without optional accessories Switchboard side Condensation coil side Minimum clearance required 0101 0121-1204 mm mm 2000 2000 1500 2000 H A B 309 Packaged WISDOM-R 0101÷1204 Versions B base version Features Reversible rooftop unit, with heat recovery for medium crowding applications 43,0 - 422 kW Unit Description Unit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The standard execution is FCC (Centrifugal Free-Cooling with supply and return fans). Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency. 310 REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). STATIC RECOVERY WITH CROSS FLOWS The air/air cross flow exchangery allows a constant and efficient exhaust airflow energy recovery. The excellent efficiency values (more than 50%) in winter conditions and no power consumption (there are no moving parts) give a concrete energy and economic saving. COMFORT The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. FLEXIBILITY Climaveneta offers units with innumerable choices for the supply and return airflows directions. Main accessories UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) PLATE SCROLL AXIAL CENTRIFUGAL r HFC R-410A FREE COOLING COOLING HEATING WISDOM-R / B Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) OUTLET FANS Supply air flow rate Available static pressure (3) Power Input SUCTION FANS/BLOWERS Nominal air flow Useful static head (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A B H Operating weight 0121 0151 0102 0122 0152 0182 0202 0252 0302 kW 43 51,5 59,7 42,6 51,8 61 68,4 83,2 107 115 135 29 34 39,5 28,8 34 41 47,4 56,4 71,6 79,5 90,9 kW 8,40 11,9 12,9 8,49 13 13,3 15 17,8 23,6 27,6 29,9 kW kW 41,7 6,81 53,2 9,59 58,2 10,1 40,9 6,61 54 10,2 59,6 10,3 66 10,8 80,1 13,6 103 17,5 113 19,8 132 22,7 m3/h Pa kW 6500 264 1,50 7800 314 2,20 8500 230 2,20 6500 264 1,50 7800 314 2,20 8600 210 2,20 10500 365 4 13000 240 3 15500 275 4,40 17500 330 6 21000 350 8 m3/h Pa kW 6500 194 1,10 7800 223 1,50 8500 194 1,50 6500 194 1,10 7800 223 1,50 8600 188 1,50 10500 235 2,20 13000 159 2,20 15500 150 3 17500 200 4,40 21000 150 6 N. 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 79 63 79 63 79 63 79 63 79 63 79 63 79 63 85 68 85 68 85 68 88 71 5250 1780 1640 1500 5250 1780 1640 1540 5250 1780 1640 1580 5250 1780 1640 1500 5250 1780 1640 1540 5250 1780 1640 1610 5250 1780 1640 1650 6450 2330 1790 2190 6450 2330 1790 2270 6450 2330 1790 2330 6450 2330 1790 2450 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204 139 157 188 206 230 263 313 341 380 402 422 mm mm mm kg kW kW 95,7 108 125 138 156 196 235 262 282 290 297 kW 28,4 36,3 40,8 45,9 54,2 63,1 70,4 81,5 87,5 95,2 108 kW kW 134 21,8 152 26,8 179 30,7 203 36,3 222 39,3 262 48,6 310 53,6 337 59,6 372 65 404 72,9 437 84,4 m3/h Pa kW 21000 350 8 23500 440 11 27000 240 8 29000 370 11 32000 460 15 45000 290 12 50000 365 16 54000 200 22 56000 370 30 56000 370 30 56000 370 30 m3/h Pa kW 21000 150 6 23500 150 8 27000 125 6 29000 189 8 32000 258 11 45000 295 12 50000 380 16 54000 200 22 56000 450 30 56000 450 30 56000 450 30 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 88 71 88 71 94 76 94 76 94 76 * * * * * * * * * * * * 6950 2330 1820 2550 6950 2330 1820 2640 6950 2340 2380 3240 6950 2340 2380 3350 6950 2340 2380 3490 11080 2330 2350 5470 11080 2330 2350 5730 11080 2330 2350 5730 11080 2330 2350 5870 11080 2330 2350 6090 11080 2330 2350 6100 mm mm mm kg Note: 1 Cooling: External 35°C 50% r.h. / Internal 27°C 47% r.h. / Mix 50 % 2 Heating: External 7°C 87% r.h. / Internal 20°C 50% r.h. / Mix 50 % 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. 5 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base. Minimum clearance required 0101-0302 Switchboard side Condensation coil side 0352 kW Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) OUTLET FANS Supply air flow rate Available static pressure (3) Power Input SUCTION FANS/BLOWERS Nominal air flow Useful static head (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) Sound pressure (5) SIZE A B H Operating weight 0101 mm mm 1500 2000 0352-1204 0 0 H A B 311 Packaged WISDOM-T-R 0101÷1204 Versions B base version Features Cooling only rooftop unit, with heat recovery for medium crowding applications 43,5 - 425 kW Unit Description Unit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The standard execution is FCC (Centrifugal Free-Cooling with supply and return fans). Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 312 REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). STATIC RECOVERY WITH CROSS FLOWS The air/air cross flow exchangery allows a constant and efficient exhaust airflow energy recovery. The excellent efficiency values (more than 50%) in winter conditions and no power consumption (there are no moving parts) give a concrete energy and economic saving. COMFORT The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. FLEXIBILITY Climaveneta offers units with innumerable choices for the supply and return airflows directions. Main accessories UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊHeating resource: hot water coil, electrical heater, burner methane gas UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) PLATE SCROLL AXIAL CENTRIFUGAL r HFC R-410A FREE COOLING COOLING WISDOM-T-R / B Models 0101 COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) OUTLET FANS Supply air flow rate Available static pressure (2) Power Input SUCTION FANS/BLOWERS Nominal air flow Useful static head (2) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A B H Operating weight 0151 0102 0122 0152 0182 0202 0252 0302 kW 43,5 52 60,1 42,9 52,5 59,3 69,1 83,6 103 117 135 29,1 34,1 39,7 28,9 34,3 40,5 47,6 56,6 70,5 79,9 90,9 kW 8,30 11,6 12,7 8,30 12,6 14 14,7 17,4 25,2 27,1 29,9 m3/h Pa kW 6500 264 1,50 7800 314 2,20 8500 230 2,20 6500 264 1,50 7800 314 2,20 8600 210 2,20 10500 365 4 13000 240 3 15500 275 4,40 17500 330 6 21000 350 8 m3/h Pa kW 6500 194 1,10 7800 223 1,50 8500 194 1,50 6500 194 1,10 7800 223 1,50 8600 188 1,50 10500 235 2,20 13000 159 2,20 15500 150 3 17500 200 4,40 21000 150 6 N. 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 dB(A) dB(A) 79 63 79 63 79 63 79 63 79 63 79 63 79 63 85 68 85 68 85 68 88 71 5250 1780 1640 1500 5250 1780 1640 1540 5250 1780 1640 1580 5250 1780 1640 1500 5250 1780 1640 1540 5250 1780 1640 1610 5250 1780 1640 1650 6450 2330 1790 2190 6450 2330 1790 2270 6450 2330 1790 2330 6450 2330 1790 2450 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204 mm mm mm kg kW 135 158 189 208 233 265 315 340 382 404 425 kW 94,9 109 125 139 156 196 236 254 283 291 296 kW 30,6 35,5 40,1 45,1 53,1 61,7 69,2 79,3 85,8 93,9 106 m3/h Pa kW 21000 350 8 23500 440 11 27000 240 8 29000 370 11 32000 460 15 45000 290 12 50000 365 16 54000 200 22 56000 370 30 56000 370 30 56000 370 30 m3/h Pa kW 21000 150 6 23500 150 8 27000 125 6 29000 189 8 32000 258 11 45000 295 12 50000 380 16 54000 200 22 56000 450 30 56000 450 30 56000 450 30 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) dB(A) 88 71 88 71 94 76 94 76 94 76 * * * * * * * * * * * * 6950 2330 1820 2550 6950 2330 1820 2640 6950 2340 2380 3240 6950 2340 2380 3350 6950 2340 2380 3490 11080 2330 2350 5470 11080 2330 2350 5730 11080 2330 2350 5730 11080 2330 2350 5870 11080 2330 2350 6090 11080 2330 2350 6100 mm mm mm kg Note: 1 Cooling: External 35°C 50% r.h. / Internal 27°C 47% r.h. / Mix 50 % 2 ESP for standard configuration (optional accessories not included/calculated) 3 Sound power on the basis of measurements made in compliance with ISO 3744. 4 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base. Minimum clearance required 0101-1204 Switchboard side Condensation coil side 0352 kW Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) OUTLET FANS Supply air flow rate Available static pressure (2) Power Input SUCTION FANS/BLOWERS Nominal air flow Useful static head (2) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (3) Sound pressure (4) SIZE A B H Operating weight 0121 mm mm 1500 2000 H A B 313 Packaged WET-RMT 0015÷0101 Versions B base version Features WET line unit for water loop systems, indoor installation 7,2 - 34,4 kW Unit Description Unit for indoor installation (in ceiling mounted or inserted behind a suspended ceiling), reversible and direct expansion for the air conditioning, with scroll compressors running on R410A. Panels and frame in hot-dip galvanised sheet steel, electric centrifugal supply fan. Hydraulic and electrical connections are simple thanks to the compact size and reduced weight of the units; maintenance is simple as all the components can be reached by removing just one panel. Commands S3 The S3 controller features ease of use and nice design. The regulation is reliable thanks to the algorithms developed and to the availability of a multi-level menu with differentiated access modes. The controller includes the control board, mounted in the unit, the user interface with keypad and LCD display, with 4 lines, to be placed in the room (supplied separately and mandatory) and a remote air probe for air duct. The user interface allows the language selection (Italian, English, German). The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). This allows to define operating status and modes. As standard, serial connectivity via ModBus protocol is featured, allowing the supervision by proprietary devices or the integration in third party systems. Supervision can be also implemented via optional protocols (Bacnet or Echelon LonWorks). 314 REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). FUCNTIONALITY The constructional simplicity ensures high reliability of use the minimum acoustic impact, also thanks to the special care given to insulation and aerodynamic profiles of the air supply area. EFFICIENCY The use of the top quality parts ensures maximum operating efficiency in all situations of plant design requirement. COMPACTNESS Units with reduced height making them especially suitable for installation in suspended ceilings and for ducted supply and return. INSTALLATION AND SERVICING The installation is simply for the reduced dimensions and the limited weight, while the servicing is made easier because all parts can be reached by removing just one panel. Main accessories UÊManual on/off valves UÊTwo way motorized ON/OFF valve UÊPressure-solenoid valve UÊAmbient air sensor SCROLL CENTRIFUGAL r HFC R-410A COOLING HEATING WET-RMT / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressors power input (1) HEATING ONLY Heating capacity (2) Compressors power input (2) PLATE EXCHANGER Water flow INTERNAL FANS Airflow rate Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) SIZE A B H Operating weight 0015 0021 0031 0041 0061 0065 0071 0081 0091 0101 kW kW kW 7,20 5,83 1,60 9 7,29 1,90 11,7 9,48 2,40 14,3 11,6 3 17,3 14 3,60 9 16,4 4,20 23,3 18,9 4,80 25,5 20,7 5,30 29,3 23,7 5,90 34,4 27,9 6,90 kW kW 7 1,80 8,80 2,10 11,2 2,70 13,8 3,30 16,5 3,90 19,4 4,50 22,2 5,10 24,4 5,60 27,9 6,30 32,6 7,40 m3/h 1,26 1,56 2,02 2,48 3 3,50 4,03 4,42 5,05 5,93 m3/h Pa kW 1300 100 0,24 1600 100 0,24 2300 100 0,50 2700 100 0,50 3100 120 0,50 3600 120 0,50 4200 120 0,74 4600 120 0,73 5200 120 0,74 6100 120 0,74 N. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 dB(A) 67 69 71 72 73 74 74 76 77 78 mm mm mm kg. 900 705 450 103 900 705 450 111 955 972 500 123 955 972 500 155 1092 1069 573 245 1092 1069 573 - 1135 1114 663 255 1135 1114 663 - 1455 1135 732 293 1455 1135 732 310 Note: 1 Cooling: Indoor air 27°C 47% R.H. / Water loop temperature IN 29°C OUT 35°C 2 Heating: Indoor air 20°C 50% R.H. / Water loop temperature OUT 15°C 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power measured in standard operating conditions without air ducts. Minimum clearance required 0015-0101 Switchboard side Raising points side mm mm 0 0 H A B 315 Packaged WET ENTHALPY 0102÷0604 Versions B base version Configurations PC PV PP function for constant water flow system function for variable water flow system function for disposable water system Features High efficiency WET line unit for water loop systems, with enthalpy recovery, outdoor installation 50,6 - 262 kW Unit Description Autonomous rooftop unit, water/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function. Commands AIR3000SE The AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units. 316 VARIABLE AIRFLOW FOR AIR TREATMENT SECTION The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). ROTARY-TYPE ENTHALPY RECOVERY The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values. PLUG-FAN VENTILATION The plug-fan supply and return fan section joins the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. Main accessories UÊEnthalpy free-cooling UÊCO2 control sensor for air quality UÊHot gas post heating UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) UÊHigh efficiency filters: electronic or rigid pocket F7 ROTARY SCROLL PLUG FAN FREE COOLING COOLING HEATING WET ENTHALPY / B Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) PLATE EXCHANGER Water flow OUTLET FANS Supply air flow rate Available static pressure (3) Power Input SUCTION FANS/BLOWERS Nominal air flow Useful static head (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (4) SIZE A B H Operating weight 0102 0122 0152 0182 kW 50,6 62,5 71,7 83,8 103 kW 32,4 39,8 45 53,9 64,6 kW 6,90 9,20 10,8 12,9 13,9 kW kW 50,7 7,90 64,8 11,6 74 12,4 86,7 14,8 m3/h 6,30 8,03 9,40 m3/h Pa kW 6500 250 1,50 7800 250 1,96 m3/h Pa kW 6500 150 1,04 N. dB(A) mm mm mm kg 0202 0252 0302 0352 0364 0404 0454 0504 0604 130 143 171 175 193 211 241 262 80,7 90,5 109 110 121 138 153 168 18,1 20,5 24,4 26,1 28 32 36 41,2 102 15,9 131 19,9 146 22,9 174 25,8 178 28 199 31,7 219 39,9 251 41,2 279 49,2 11 12,8 16,6 18,4 22,2 23 25,4 27,8 32,3 35,6 8600 250 2,24 10500 250 3,18 13000 250 2,74 15500 250 3,68 17500 250 4,66 21000 250 5,22 21000 250 5,22 23000 250 6,38 27000 250 7,84 29000 250 9,06 32000 250 11,3 7800 150 1,62 8600 150 1,92 10500 150 2,82 13000 150 2 15500 150 2,68 17500 150 3,98 21000 150 3,66 21000 150 3,66 23000 150 4,50 27000 150 4,42 29000 150 5,16 32000 150 6,82 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 4/2 4/2 4/2 88 89 90 91 94 94 94 95 95 96 97 97 98 3760 1780 1490 1430 3760 1780 1490 1460 3760 1780 1490 1520 3760 1780 1490 1540 4035 2330 2240 2430 4035 2330 2240 2480 4035 2330 2240 2540 4830 2330 2240 3000 4830 2330 2240 3110 4830 2330 2240 3130 5200 2330 2240 3620 5200 2330 2240 3710 5200 2330 2240 3760 Note: 1 Cooling: Outdoor air 35°C 50% R.H. / Indoor air 27°C 47% R.H. / Mix 30% / Water loop temperature IN 29°C OUT 35°C 2 Heating: Outdoor air 7°C 87% R.H. / Indoor air 20°C 50% R.H. / Mix 30% / Water loop temperature OUT 10°C 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power measured in standard operating conditions without air ducts. Minimum clearance required 0102-0604 Switchboard side Raising points side mm mm 1500 2000 317 Packaged WET-RTF 0102÷1204 Versions B base version Configurations PC PV PP function for constant water flow system function for variable water flow system function for disposable water system Features REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP=0). WET line unit for water loop systems, outdoor installation 37,2 - 396 kW Unit Description Unit for indoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The unit in standard version, STD, can treat recirculating-only air; other available executions (optionals) are MIX (return air and fresh air mix), FCS (Standard Free-Cooling with supply fans) or FCC (Centrifugal Free-Cooling with supply and return fans). Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 318 COMFORT The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. FLEXIBILITY Climaveneta offers units with innumerable choices for the supply and return airflows directions. Main accessories UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) r HFC R-410A SCROLL CENTRIFUGAL FREE COOLING COOLING HEATING WET-RTF / B Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) HEATING ONLY Heating capacity (2) Compressors power input (2) CONDENSER Water flow rate OUTLET FANS Supply air flow rate Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS (4) Sound power SIZE A (5) B (5) H (5) Operating weight (5) 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 kW kW kW 37,2 27,9 6,85 46,5 32,6 9,24 54,6 39,6 10,7 62,3 45 11,3 73,8 53 13,8 96,3 69,3 18,3 106 75,7 20,4 121 84,5 21,6 125 90,2 22,6 144 102 27,5 kW kW 42,6 7,87 55,2 11,9 64,2 12,2 71,9 13,1 84,5 16,1 113 21,1 126 24,9 144 25,9 146 26,3 173 33,5 mc/h 6,32 7,99 9,36 10,6 12,6 16,4 18,1 20,4 21,1 24,5 m3/h Pa kW 6500 220 1,10 7800 219 1,50 8600 315 2,20 10500 261 3 13000 208 2,20 15500 202 3 17500 269 4,40 21000 271 6 21000 271 6 23500 303 8 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 dB(A) 78 76 76 76 82 82 82 87 87 87 2200 1780 1490 710 2200 1780 1490 780 2200 1780 1490 790 2200 1780 1490 810 2470 2330 1640 1030 2470 2330 1640 1080 2470 2330 1640 1110 2470 2330 1640 1250 2470 2330 1640 1340 2470 2330 1640 1350 mm mm mm kg Models COOLING ONLY Cooling capacity (1) Sensible cooling capacity (1) Compressor power input (1) HEATING ONLY Heating capacity (2) Compressors power input (2) CONDENSER Water flow rate OUTLET FANS Supply air flow rate Available static pressure (3) Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS (4) Sound power SIZE A (5) B (5) H (5) Operating weight (5) 0454 0504 0604 0704 0804 0904 1004 1104 1204 kW kW kW 170 102 32,1 187 131 36,4 215 150 40,4 243 172 48,2 288 207 55,6 314 224 61,7 352 250 67,4 375 258 74,5 396 266 82,8 kW kW 199 37,2 225 44,4 252 48,7 283 61,5 333 66,4 368 76,9 410 82,8 442 92,4 488 109 mc/h 28,9 32 36,6 41,8 49,2 53,8 60,1 64,4 68,7 m3/h Pa kW 27000 215 6 29000 261 8 32000 333 11 45000 235 12 50000 255 16 54000 400 22 56000 290 30 56000 290 30 56000 290 30 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) 92 92 92 * * * * * * 2470 2330 2240 1570 2470 2330 2240 1630 2470 2330 2240 1750 5000 2330 2240 2770 5000 2330 2240 3000 5000 2330 2240 3200 5000 2330 2240 3250 5000 2330 2240 3300 5000 2330 2240 3350 mm mm mm kg Note: 1 Cooling: Indoor air 27°C 47% R.H. / Water loop temperature IN 29°C OUT 35°C 2 Heating: Indoor air 20°C 50% R.H. / Water loop temperature OUT 10°C 3 ESP for standard configuration (optional accessories not included/calculated) 4 Sound power on the basis of measurements made in compliance with ISO 3744. 5 Unit in standard configuration/execution, without optional accessories Minimum clearance required 0102-1204 Switchboard side Raising points side mm mm 1500 2000 319 Packaged WET-RTF-R 0102÷1204 Versions B base version Configurations PC PV PP function for constant water flow system function for variable water flow system function for disposable water system Features WET line unit for water loop systems, with heat recovery, outdoor installation 44,8 - 468 kW Unit Description Unit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The standard execution is FCC (Centrifugal Free-Cooling with supply and return fans). REFRIGERANT GAS R410A The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0). STATIC RECOVERY WITH CROSS FLOWS The air/air cross flow exchangery allows a constant and efficient exhaust airflow energy recovery. The excellent efficiency values (more than 50%) in winter conditions and no power consumption (there are no moving parts) give a concrete energy and economic saving. COMFORT The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions. SAFE USE The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on. FLEXIBILITY Climaveneta offers units with innumerable choices for the supply and return airflows directions. Main accessories Commands AIR3000 The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 320 UÊHot gas post heating UÊCO2 control sensor for air quality UÊHigh efficiency filters: electronic or rigid pocket F7 UÊEnthalpy free-cooling UÊSet-up for remote connectivity with ModBus/Echelon protocol cards UÊRemote keyboard (distance to 200m and to 500m) PLATE r HFC R-410A SCROLL CENTRIFUGAL FREE COOLING COOLING HEATING WET-RTF-R / B Models COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) PLATE EXCHANGER Water flow OUTLET FANS Supply air flow rate Available static pressure (3) Power Input SUCTION FANS/BLOWERS (3) Nominal air flow Useful static head Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power SIZE A B H Operating weight 0102 0122 0152 0182 0202 kW 44,8 55,5 65,1 74,4 89,4 kW 33,8 39,5 47,9 54,5 66,1 kW 6,95 9,24 10,6 11,2 13,7 kW kW 52,1 7,48 66 11,5 76,8 11,6 85,8 12,6 m3/h 6,32 7,99 9,36 m3/h Pa kW 6500 264 1,50 7800 314 2,20 m3/h Pa kW 6500 194 1,10 N. dB(A) mm mm mm kg Models 0302 0352 0364 0404 114 126 143 147 169 85,8 91,3 101 107 122 18,4 20,3 21,7 22,5 27,3 103 15,6 135 20,3 150 24 166 23,9 172 25,2 202 32,2 10,6 12,6 16,4 18,1 20,4 21,1 24,5 8600 210 2,20 10500 365 4 13000 240 3 15500 275 4,40 17500 330 6 21000 350 8 21000 350 8 23500 440 11 7800 223 1,50 8600 188 1,50 10500 235 2,20 13000 159 2,20 15500 150 3 17500 200 4,40 21000 150 6 21000 150 6 23500 150 8 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 78 78 78 78 84 84 84 89 89 89 4500 1780 1490 1300 4500 1780 1490 1360 4500 1780 1490 1370 4500 1780 1490 1400 5470 2330 1640 1860 5470 2330 1640 1910 5470 2330 1640 1940 5470 2330 1640 2180 5470 2330 1640 2230 5470 2330 1640 2370 0454 COOLING ONLY Cooling capacity + Recovery (1) Sensible cooling capacity + Recovery (1) Compressor power input (1) HEATING ONLY Heating capacity + Recovery (2) Compressors power input (2) PLATE EXCHANGER Water flow OUTLET FANS Supply air flow rate Available static pressure (3) Power Input SUCTION FANS/BLOWERS (3) Nominal air flow Useful static head Power Input COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power SIZE A B H Operating weight 0504 0604 0704 0804 0904 1004 1104 1204 kW 200 219 250 297 348 382 420 446 468 kW 145 155 177 211 249 278 297 305 311 kW 32,2 36,3 40,6 49,6 57,1 64,2 69,5 76,3 85,2 kW kW 234 35,7 263 42,7 292 46,8 334 57,2 390 61,8 429 70,1 473 76,7 505 85,4 552 100 m3/h 28,9 32 36,6 41,8 49,2 53,8 60,1 64,4 68,7 m3/h Pa kW 27000 240 8 29000 370 11 32000 460 15 45000 290 12 50000 365 16 54000 200 22 56000 370 30 56000 370 30 56000 370 30 m3/h Pa kW 27000 125 6 29000 189 8 32000 258 11 45000 295 12 50000 380 16 54000 200 22 56000 450 30 56000 450 30 56000 450 30 N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 dB(A) 94 94 94 * * * * * * 5470 2330 2240 2690 5470 2330 2240 2740 5470 2330 2240 2830 9500 2330 2240 4450 9500 2330 2240 4650 9500 2330 2240 4700 9500 2330 2240 4780 9500 2330 2240 5000 9500 2330 2240 5050 mm mm mm kg Note: 1 Cooling: Outdoor air 35°C 50% R.H. / Indoor air 27°C 47% R.H. / Mix 50% / Water loop temperature IN 29°C OUT 35°C 2 Heating: Outdoor air 7°C 87% R.H. / Indoor air 20°C 50% R.H. / Mix 50% / Water loop temperature OUT 10°C 3 ESP for standard configuration (optional accessories not included/calculated) Minimum clearance required 0102-1204 Switchboard side Raising points side 0252 mm mm 1500 2000 H A B 321 Y YS YSTE 322 EMS systems systems 323 Systems MANAGER 3000 Group regulation device Features Unit Description Manager3000 allows the regulation within a group of hydronic units. The controller features high-level algorithms and user interface. The controller is suitable for the management of 2- or 4-pipe systems, with regulation on one water circuit, for chilleror heat pump units and relevant mode change-over, and also with regulation on two circuits, with independent set-points and parameters, thus exploiting the simultaneous supply of chilled- and hot water. The controller manages up to 8 units, with activation logic focused at the balancing of operation times and at the achievement of the highest energy efficiency. It is possible to define conditions of dynamic stand-by and priority as regards the units activation. It is also feasible the rotation among the systems units, also in cases of constant load. The alarm management is featured, with plain text descriptions and possible notification to remote recipients. Two relay outputs are available, associated to unit- and device alarms. The user interface allows a safe and easy use, thanks to its touch-screen display, back-lit 8.4” type. The multi-level menu features the language selection and differentiated access profiles(user and maintenance). The circuit temperatures and the status of both system- and unit- operation are displayed, via one overview page plus detailed pages. The regulation can be based on proportional- or proportional+integral logics, or also on a dead-band algorithm with dynamic adjustment, with relevant temperature inputs managed by the device. Features as set-point offset, also referred to the outdoor temperature, and demand limit are included, with relevant analog inputs. The device is integrated in the best way with the units, preventing simultaneous activations or resources and optimizing efficiency, overall inrush current values and also operation of water pumps possibly associated to the units. The WebManager option allows the access to the device and its settings, via any computer, with direct- or LAN-based connection, therefore also via internet resources; this is associated to the availability of historical charts for the main operating variables. The “Variable Primary Flow” option represents a unique regulation dedicated to hydronic systems with variable water flow. This represents a crucial contribution to the reduction of the costs related to the hydraulic plant and its operation. It is available as option the interface with the Demetra metering device: thus it is possible to acquire and log the values of the system units electric consumption, together with their operating status; this allows therefore to analyze the systems operating performances throughout time, in terms of both absorbed energy and cooling / heating capacities, consistently with the implementation of enhanced energy management policies for the building. 324 OPTIONS Integration in BMS /BAS via ModBus, Echelon LonTalk or Bacnet protocols Modem or ADSL router Log of main variables and alarm events WebManager, with capabilities of remote access and optionale display of logged data charts. VPF implementation. Models max number of managed units Management of hydronic units Regulation on one water circuit Regulation on two water circuits (4 pipe systems) User interface with display and commands, touchscreen, multi-language Alarm management Management of stand-by, priority, rotation Supervision via web pages (WebManager) Integration into BMS/BAS systems Acquisition and log of the main operating variables Modem gprs or pstn, integrated Router ADSL, integrated Compatibility with variable primary flow systems Compatibility with metering device Demetra MANAGER 8 X X X X X X opt opt opt opt opt opt opt Systems SEQUENCER SEQUENCER÷SEQUENCER Group regulation device Features Integration in BMS /BAS via ModBus, Echelon LonTalk or Bacnet protocols Unit Description The device allows the regulation within a group of hydronic units. The controller features a high-level algorithm (regulation profile GR2000). The controller is suitable for the management of 2-pipe systems, with regulation on one water circuit, for chiller- or heat pump units and relevant mode change-over. The controller manages up to 5 units, with activation logic focused at the balancing of operation times and at the achievement of the highest energy efficiency. It is possible to define conditions of dynamic stand-by and priority as regards the units activation. The alarm management, with one relay output, is available. On the LCD user interface the main variables, related to the system and the units, are displayed. The regulation can be based on proportional- or proportional+integral logics. The device is integrated in the best way with the units, preventing simultaneous activations of resources and optimizing the efficiency and the overall inrush current value. 325 Models Regulation of multiple units, 1 water circuit Regulation of multiple units, 2 water circuits Management of dynamic stand-by, priority, demand limit Integration in bms / bas systems Management of hydronic units Max number of devices User interface with display and commands Monitoring of alarms and unit status SEQUENCER X X opt X 5 X X Systems DEMETRA Metering device Models max number of managed units Management of hydronic units Metering on one water circuit Metering on two water circuits (4 pipe systems) Compatibility with Manager3000 Compatibility with FWS3000 Unit Description The new Demetra device represents the solution for the most evolved and up-to-date requirements concerning the energy management of HVAC hydronic systems Demetra (DEvice for Metering of Energy TRAnsfers) is associated to the Climaveneta devices, Manager3000 or FWS3000 and enables the metering of both electric energy consumption and cooling / heating performances. Demetra is compatible with hydronic systems with one or two hydraulic circuits. The combination of Manager3000 and Demetra represents the optimized integration between systems regulation and measurement of the benefits, energy-wise, arising from such regulation. With Demetra it is possible the acquisition, at selectable intervals, of the electric energy consumption for each unit, the water flow rates (optional, care of customer) and of the outdoor air temperature. These values are integrated with the operating status of each unit, as detected by Manager3000 or FWS3000 (on these devices, the options of USB key and compatibility with Demetra are required). Demetra is provided complete with power supply meters, associated to each unit belonging to the system. The flow rate meters, for each hydraulic circuit, are optional, care of customer. The enhanced features of this solution allow to obtain directly the cooling- and heating energy values supplied, according to the operation conditions detected on the units at each sampling. By this way, historical files are obtained, easily downloadable also via LAN / internet, thus enabling a deep and complete analysis of systems performances throughout time. In particular, the following data are managed: Electric energy consumption Cooling energy output, for the relevant water circuit Heating energy output, for the relevant water circuits Outdoor air temperature Water inlet- and outlet temperatures, for the relevant water circuits Water flow rate, for the relevant water circuits (optional, care of customer) Duration time for the different operating regimes, for each unit 326 DEMETRA 8 X X X X X Systems FWS3 Supervisory device Features Integration in bms / bas systems, with modbus protocol Modem or ADSL router Log of main variables and alarm events Unit Description Supervisory device for one Climaveneta unit. Supervision can be operated via any computer, with direct- or LAN-based connection. It is therefore achieved the internetbased management of the resources, thanks to the built-in web-server and to the availability of web pages specifically defined.The supervision achieved by this way does not require the installation of any additional software on the computer and utilizes the most common browsers. This allows the use of any computer connected to the network or web.A RS-485 serial connection is available for the communication with the slave device (hydronic unit: chiller or heat pump. Rooftop).The access to the supervision is easy and safe, thanks to the use of password. It is possible to visualize a complete list of unit operational variables: temperatures, humidity, indoor air quality, status of the unit. It is also available the display of alarms, with plain text descriptions and possible notification to remote recipient. The setting of the main operational parameters, for each unit, is also allowed: unit status, mode, set-point, time scheduling (based on 4 days, 10 time belts per day). 327 Models Supervision via web pages Integration in bms / bas systems Access via lan Management of rooftop- or wet units Management of hydronic units Monitoring of alarms and unit status Remote notification of alarms Log of main regulation variables and alarm events Built-in modem, gprs or pstn type Built-in adsl router FWS3 X opt X X X X X opt opt opt Systems FWS3000 Supervisory device Features Unit Description Supervisory device for a system composed of Climaveneta units. Supervision can be operated via any computer, with direct- or LAN-based connection. It is therefore achieved the internet-based management of the resources, thanks to the built-in web-server and to the availability of web pages specifically defined both for the overall system monitoring and the access to detailed information about each unit. The supervision achieved by this way does not require the installation of any additional software on the computer and utilizes the most common browsers. This allows the use of any computer connected to the network or web. A RS-485 serial connection is available for the communication with the slave devices, up to 15 connected units. FWS3000 is particularly effective for the supervision of systems composed of packaged or WET units. The access to the supervision is easy and safe, thanks to the use of password. It is possible to visualize a complete list of unit operational variables: temperatures, humidity, indoor air quality, status of the unit. This is associated to the availability of historical charts for the main operating variables. It is also available the display of alarms, with plain text descriptions and possible notification to remote recipient. The setting of the main operational parameters, for each unit, is also allowed: unit status, mode, set-point, time scheduling (based on 4 days, 10 time belts per day). Various levels of customization are offered, for both the web pages and connectivity-related functions. It is available as option the interface with the Demetra metering device: thus it is possible to acquire and log the values of the system units electric consumption, together with their operating status; this allows therefore to analyze the systems operating performances throughout time, in terms of both absorbed energy and cooling / heating capacities, consistently with the implementation of enhanced energy management policies for the building. 328 Customization of the web pages Application package dedicated to high-attendance or cinema applications Application package dedicated to the energy metering and billing, with water-loop systems Integration in bms / bas systems, with modbus protocol Modem or ADSL router Log of main variables and alarm events Models max number of managed units Management of packaged or hydronic systems Alarm management Supervision via web pages Integration into BMS/BAS systems Acquisition and log of the main operating variables Modem gprs or pstn, integrated Router ADSL, integrated Compatibility with metering device Demetra FSW3000 15 X X X opt opt opt opt opt 329 SYSTEMS Standard functions Centralised hydronic air-conditioning system for cooling, heating and domestic hot water production Description Centralized management and control system, via a user interface consisting in a compact PC for flush mounting, which features Touch Screen commands. Capability of control up to 224 devices (terminals, chillers or heat pumps, other components) for each serial network. Products suitable to integration Hydronic terminals UÊ*ÀviÃÃ>Êv>VÃÊÜÌ ÊÃÞV ÀÕÃÊÌÀÊiiVÌÀVÊÃÜÌV iÃÊ UÊ*ÀviÃÃ>Êv>VÃÊÜÌ ÊV>LiÌÊÀÊVVi>i`ÊÛiÀÃÊÜÌ ÊViÌÀvÕ}>Êv>Ê> UÊ*ÀviÃÃ>Êv>VÃÊVVi>i`ÊÛiÀÃÊ } Ê i>`Ê>Ê* UÊ,iÃ`iÌ>Êv>VÃÊÜÌ ÊV>LiÌÊÀÊVVi>i`ÊÛiÀÃÊ / UÊ >ÃÃiÌÌiÊÌÞ«iÊv>VÃÊÃ}iÉ`ÕLiÊVÊvÀÊ`ÕLiÉvÕÀÊ««iÊViVÌÃÊ81 UÊÕVÌi`ÊÌÞ«iÊv>VÃÊÜ>ÕÌi`ÊVÌÀÃÊÀÊÜÌ ÊÀiÌiÊVÌÀÊ7 Water chillers and heat pumps UÊ`iÃÊ«ÀiÃiÌÊÊ >ÛiiÌ>ÊiÊ-ÞÃÌiÊ,/]Ê, ]Ê -]Ê - ]iÌV°®Ê>`Ê iÀV>ÊEÊ`ÕÃÌÀ>ÊV>Ì>logues Auxiliary components suitable to be managed via digital contact UÊ""vvÊLiÀÃ]Ê""vvʫիÃ]ÊâiÊÛ>ÛiÃ]ÊiÌV° 330 MANAGEMENT For each terminal, provided with wall-mount or built-in controller, it is possible to select set-point, operation mode, fan speed. These settings can be further modified either locally, by acting on each controller, or in a centralized way, by acting on the touch-screen. For the water chillers and heat pumps, centralized access allows to switch the units on and off and selecting the operation mode. SUPERVISION At any moment it is possible to display via touch-screen the operation status of the terminals connected to the serial line. For each room: temperature, set-point, operation mode are displayed. For the water chillers and heat pumps: operation mode, temperatures and possibly active alarms can be displayed. QUICK SETTINGS Via centralized access it is possible to switch all terminals on or off simultaneously; for the water chillers and heat pumps, it is allowed to select the set-point value, the operation mode and to command the switch-on. TIMER A timer function is implemented, enabling to switch on or off the whole system or selected zones, with scheduling on daily and weekly basis. LIMITS At local level, the setting ability can be limited, by disabling some or all functions of each controller (ventilation, operation mode), or reducing the adjustable range of setpoint values to few degrees (e.g. ±1°C). By the same way, each controller can be disabled in order to prevent any change at local level and assign full control of the zone to the supervision. ECONOMY CONTACT Local controllers of the terminals are provided with an Economy contact which, connected to voltage-free contacts of various types (room access badge, window contact, presence detector, etc.) thus allowing to manage an “economy” operation profile (minimum speed ventilation, setpoint value increased in summer mode and decreased in winter mode). The operation profile is reset to normal by closing the contact. COMPONENTS MANAGEMENT It is furthermore possible to manage, by means of dedicated voltage-free contacts, the on-off switching of further components of the cooling / heating system, such as pumps, zone valves or boilers. Operation diagram Note 1. StarTouch: Compact user interface panel, with a 5,7” TFT colour display, suitable for Windows CE-based applications. I/O board includes 2 USB connectors type A (host), 1 RJ45 connector for Ethernet 10/100, 1 DB9 connector for the RS232 serial port, screw terminals for the RS485 serial port, 1 USB connector client type. 2. BusAdapter: Interface enabling the connection of the electronic controllers AT/ATW to a RS485 network; one interface required for each controller. 3. AT: Plug-in control; features: on-off, operation mode, fan speed mode, set-point selection, economy contact, window contact, remote cool/heat, hot start and too-cool functions. 4. ATW: Wall-mounted control; features: on-off, operation mode, fan speed mode, set-point selection, economy contact, window contact, remote cool/heat, hot start and too-cool functions. 5. BusCE: kit including controller and BusAdapter; to be used when it is necessary to conceal both components, managing the terminal via supervision or infra-red remote control. 6. IR: kit for the infra-red remote control composed of an infra-red receiver and associated remote keypad, which replicates all functions of the electronic controller. 7. HSW7: Mini-chiller control; it can be directly integrated in the serial line via BusAdapter (standard on units: BRAT, BRAN, BRA, BRH, etc.). 8. PowerBusCE: Interface enabling the connection of the auxiliary plant components (pumps, boilers, valves, etc.) and some type of chillers and heat pumps. 9. Serial cable: Serial communication cable: 2-conductor twisted pair, shielded, cross section reference AWG22. For wiring length over 1.5 km, feasibility assessment is required. This operation diagram is purely representative and qualitative. Refer to the available technical documentation for compatibility and connection mode. 331 A 332 AHU AHU AHU 333 AHU WIZARD Features UNIT COMPLETE WITH REGULATION The unit includes the controller for the regulation of all the parameters required for the air treatment. The electrical board is built-in and complete with wiring, while the components such as 3-way valves, probes, damper motors and humidifiers (optional) are provided factorymounted and wired CE MARKING As the unit does not require any further on-site intervention upon it, Climaveneta provides Wizard Automatic completed with CE marking, Class A REDUCED TIMING Thanks to the use of a unit ready to operate without any further intervention, the commissioning timing results strongly reduced. SAFETY AND RELIABILITY Climaveneta becomes the single contact reference for any malfunctioning related to the unit. MINIMAL SYSTEM START-UP COSTS The on-site placement of a “plug & play” unit remarkably reduces the use of skilled labour, associated to the commissioning of a traditional air handling unit, thus reducing the costs Air handling unit 0-115000 m3/h Unit Description The Wizard range of Air-Handling Units incorporate the entire design experience of Climaveneta in order to fully satisfy all market requirements in the various sectors of application. Tailored though massproduced industrial products, these high quality and reliable units guarantee total safety.Traditional sectors: residential building, airports, banks, shops, hotels, museums, theatres, cinemas, auditoriums, television studios, libraries and data processing centres. Specific sectors: pharmaceutical, food, hospital, electronic, maritime applications and temperature- or contamination-controlled production processes. Commands AHU3000 The AHU3000 controller is featured as option for the air handling units. It offers functions and regulations able to satisfy the numerous combinations possible with these units. Furthermore this option enhances and simplifies the units commissioning, allowing also the interfacing towards other resources and devices. The keypad features aesthetic design, easy-to-use interface, smart LCD display. The regulation integrates numerous characteristics, depending on the units configuration and selected options: command of the dampers and of the free-cooling; regulation of the resources for heating, cooling as well as humidity and air quality; regulation and control of supply- and return fans. The diagnostics includes a complete alarm management, with the the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). 334 LEAKAGE CONTROLLER CENTRIFUGAL PLUG FAN WIZARD numerous executions available: 335 RE-HEATING HUMIDIFICATION HEATING COOLING OTH 336 HER 337 other other other BRAT-MC 0011÷0121 Versions B SL base version super-low noise version Features Coil protection grid for models 0011÷0061. Structure and base in hot-dip galvanised steel with epoxy powder paint finish. External access to control with anti-tamper device. Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar. User interface with display. Phase sequence controller for models 0071÷0121 Condensing unit Main accessories UÊRubber anti-vibration mounting kit UÊCoil protection grid for models 0071÷0121 UÊExternal main switch kit UÊHSW10 remote keyboard 4,9 - 32,9 kW Unit Description Outdoor split-system unit working with R410A refrigerant for connection with direct expansion coils or remote exchangers, with hermetic rotary scroll compressor and axial-flow fans. External panels and basement and base in galvanised sheet steel with paint finish. 338 r HFC R-410A SCROLL AXIAL COOLING BRAT-MC / B Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current Operational weight No. fans Airflow Compressor type Refrigerant Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A kg N. m3/h dB(A) dB(A) V-Ph~Hz 0011 0021 0025 0031 0041 5,6 1,9 9,2 80 1 2400 SCROLL R410A 51 65 230V~50Hz 6,6 2,2 9,8 85 1 3500 SCROLL R410A 52 66 230V~50Hz 7,5 2,5 12,4 100 1 3500 SCROLL R410A 52 66 230V~50Hz 9,6 3,4 15,6 105 1 4200 SCROLL R410A 52 66 230V~50Hz 12,7 4,1 18,7 125 2 6800 SCROLL R410A 54 69 230V~50Hz 900 640 370 900 640 370 900 940 370 900 940 370 900 1240 370 mm mm mm Models 0041 COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current Operational weight No. fans Airflow Compressor type Refrigerant Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A kg N. m3/h 12,7 4,3 8,4 125 2 6800 SCROLL R410A dB(A) 54 dB(A) 69 V-Ph~Hz 400V-3N~50Hz mm mm mm 0021 0025 0031 6,1 7,5 9,3 2,0 2,4 3,2 4,2 4,4 5,9 85 100 105 1 1 1 3500 3500 4200 SCROLL SCROLL SCROLL R410A R410A R410A 52 52 52 66 66 66 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 900 640 370 900 940 370 900 940 370 0051 0061 0071 0091 0101 0121 14,3 4,7 9,0 145 2 6800 SCROLL R410A 54 69 400V-3N~50Hz 16,5 5,3 9,7 155 2 6400 SCROLL R410A 54 69 400V-3N~50Hz 20,8 6,9 14,6 245 1 9800 SCROLL R410A 61 76 400V-3N~50Hz 23,5 7,9 15,8 250 1 9800 SCROLL R410A 61 76 400V-3N~50Hz 29,5 8,4 21,7 320 2 14000 SCROLL R410A 63 79 400V-3N~50Hz 35,8 11,4 24,6 325 2 14000 SCROLL R410A 63 79 400V-3N~50Hz 900 1240 370 900 1390 420 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 900 1240 370 Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Noise level measured at 1 m in open field conditions BRAT-MC / SL Models COOLING ONLY VERSION Nominal Cooling capacity (1) Total absorbed power (1) Absorbed current Operational weight No. fans Airflow Compressor type Refrigerant Sound pressure level (2) Sound power Electrical power supply DIMENSION L H P kW kW A kg N. m3/h dB(A) dB(A) V-Ph~Hz 0071 0091 0101 0121 20,1 6,9 12,4 245 2 7000 SCROLL R410A 59 74 400V-3N~50Hz 22,7 8,0 13,6 250 2 7000 SCROLL R410A 59 74 400V-3N~50Hz 27,8 8,8 18,6 320 3 10500 SCROLL R410A 60 76 400V-3N~50Hz 33,4 11,8 21,5 325 3 10500 SCROLL R410A 60 76 400V-3N~50Hz 1450 1200 550 1450 1200 550 1450 1700 550 1450 1700 550 mm mm mm Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.. 2 Noise level measured at 1 m in open field conditions Dimension H H H P L P L P L 339 other HCAT 0152÷0604 Versions B HT LN SL base version high efficiency, high outdoor temperature version low noise version super-low noise version Features TOTAL VERSATILITY Condensing units with scroll compressors in 4 versions, designed to satisfy all service system and application requirements. CONTINUAL FAN SPEED CONTROL The standard bi-compressor type HCAT units come fitted with continual fan speed control to guarantee more flexibility and adaptability INTEGRAL SAFETY DEVICES Standard units are all fitted with high and low pressure switches, high-pressure safety valve and magnetothermal circuit breakers on loads (bi-compressor unit only) Condensing unit 38 - 160 kW Unit Description Outdoor split-system unit for connection with direct expansion coils or remote exchangers, with hermetic rotary scroll compressors, axial-flow fans, compressor inlet and outlet valves with servicing plugs and liquid tap. External panels in Peraluman and base in galvanised sheet steel with paint finish. Refrigerant R407C, units with two and four-compressors, two refrigerant circuits. 340 r HFC R-407C SCROLL AXIAL COOLING HCAT / B Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0152 0182 0202 0252 0302 0412 0512 0524 0604 kW kW 37,7 14,5 47,0 17,9 54,7 20,3 66,5 25,3 79,8 29,6 112 39,4 139 47,8 141 55,6 160 64,7 N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 dB(A) dB(A) 78 46 79 47 79 47 81 49 81 49 85 53 85 53 94 62 94 62 1695 1120 1420 510 2195 1120 1420 570 2195 1120 1420 600 2745 1120 1420 675 2745 1120 1420 775 3245 1120 1620 910 3245 1120 1620 980 3110 2220 1700 1520 3110 2220 1700 1600 mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. HCAT / HT Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0524 0604 kW kW 146 53,3 170 60,3 N. 4/2 4/2 dB(A) dB(A) 94 62 94 62 3110 2220 1700 1620 3110 2220 2150 1700 mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. HCAT / LN Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0524 0604 kW kW 134 54,6 152 64,5 N. 4/2 4/2 dB(A) dB(A) 86 54 86 54 3110 2220 1700 1520 3110 2220 1700 1600 mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 341 HCAT / SL Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0524 0604 kW kW 132 54,1 152 63,3 N. 4/2 4/2 dB(A) dB(A) 79 47 79 47 3110 2220 1700 1620 3110 2220 2150 1700 mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. Minimum clearance required 0524-0604 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 600 600 1000 H A B 342 343 other MCAT 0501÷1422 Versions B HT LN SL base version high efficiency, high outdoor temperature version low noise version super-low noise version Features TOTAL VERSATILITY Condensing units with scroll compressors in 4 versions, designed to satisfy all service system and application requirements. SEMI-HERMETIC RECIPROCATING COMPRESSORS The MCAT units are fitted with semi-hermetic reciprocating compressors with the possibility of extra capacity control step INCORPORATED LIQUID RECEIVER Standard units are all fitted with liquid receiver to ensure best operation of the condensing section Condensing unit 119 - 325 kW Unit Description Outdoor split-system unit for connection with direct expansion coils or remote exchangers. Semi-hermetic reciprocating compressors, axial-flow fans, liquid receiver, compressor inlet and outlet valves with servicing plugs and liquid tap. External panels in Peraluman and base in galvanised sheet steel with paint finish. Refrigerant R407C, units with 1 or 2 compressors, single or double circuits. 344 AXIAL RECIPROCATING r HFC R-407C COOLING MCAT / B Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422 kW kW 119 46,7 141 55,9 115 42,8 134 51,2 160 68,2 188 81,0 203 80,3 236 93,9 282 112 297 * 325 * N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 * * * * * * * * * * * * * * * * * * * * * * 3110 2220 1540 1260 3110 2220 1540 1310 3110 2220 1540 1350 3110 2220 1540 1420 3110 2220 1540 1500 3110 2220 1540 1610 3110 2220 1990 1690 3110 2220 1990 1870 4110 2220 1990 2060 * * * * * * * * dB(A) dB(A) mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. MCAT / HT Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422 kW kW 127 46,6 149 55,5 122 43,2 143 51,5 174 63,9 211 76,5 223 77,3 256 89,5 305 109 321 351 N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 * * * * * * * * * * * * * * * * * * 3110 2220 1540 1330 3110 2220 1540 1390 3110 2220 1540 1430 3110 2220 1540 1500 3110 2220 1990 1640 4110 2220 1990 1880 4110 2220 1990 1890 4110 2220 1990 2100 5110 2220 1990 2340 dB(A) dB(A) mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. MCAT / LN Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422 kW kW 115 48,0 135 57,7 111 43,9 129 52,6 154 70,2 179 83,7 195 82,5 226 97,4 271 115 285 312 N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 * * * * * * * * * * * * * * * * * * 3110 2220 1540 1260 3110 2220 1540 1310 3110 2220 1540 1350 3110 2220 1540 1420 3110 2220 1540 1500 3110 2220 1540 1610 3110 2220 1990 1690 3110 2220 1990 1870 4110 2220 1990 2060 dB(A) dB(A) mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. 345 MCAT / SL Models COOLING Cooling capacity (1) Total power input (1) COMPRESSORS No. Compressors/No. Circuits NOISE LEVELS Sound power (2) Sound pressure (3) SIZE A B H Operating weight 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422 kW kW 114 49,0 140 56,7 110 44,9 129 53,3 154 67,9 187 80,9 203 79,9 230 95,4 280 113 295 323 N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 * * * * * * * * * * * * * * * * * * 3110 2220 1540 1370 3110 2220 1990 1450 3110 2220 1540 1460 3110 2220 1990 1560 4110 2220 1990 1780 4110 2220 1990 1880 4110 2220 1990 1890 4110 2220 1990 2100 5110 2220 1990 2340 dB(A) dB(A) mm mm mm kg Note: 1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C. 2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units. 3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level. Minimum clearance required 0501-1422 Switchboard side Switchboard opposite side Condensation coil side mm mm mm 1500 1100 2000 H B A 346 347 altro NCE 118A÷428C Versioni B LN SL Remote condenser with axial fans Unit Description Remote condensers with axial-type fans for outdoor installation. Installation may be vertical with a horizontal air outflow or, using special brackets, horizontal with an upward air outflow. The very low noise, adjustable-speed fans are excellent for use for both industrial and commercial applications. 348 base version base version super-low noise version AXIAL r HFC R-410A NCE/B Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight 118A 218A 318A 328A 118B 218B 318B 328B 55 11,7 110 23 160 38 301 77,6 68 15,8 135 30,1 197 42,9 389 87,6 m3/h dB(A) 21200 81 42400 84 63600 86 123600 89 19600 81 39000 84 58800 86 114000 89 mm mm mm kg 1880 800 1370 145 3230 800 1370 279 3230 800 1370 413 5930 800 1370 680 1880 800 1370 157 3230 800 1370 302 4580 800 1370 447 4580 800 1370 742 418B 428B 118C 218C 318C 328C 418C 428C 270 60,2 511 110 75 18,3 150 33,9 228 48,1 430 97,8 300 67,9 566 123 m3/h dB(A) 78400 86 152000 90 18400 81 36800 84 55200 86 106200 89 73600 86 141600 90 mm mm mm kg 4580 800 1370 592 5930 800 1370 982 1880 800 1370 168 3230 800 1370 324 4580 800 1370 481 4580 800 1370 804 5930 800 1370 637 5930 800 1370 1065 kW kW Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight kW kW Note: 1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C 2 Sound power on the basis of measurements made in compliance with ISO 3744. 3 Without legs kit configuration ; horizontal air flow NCE/LN Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight 118A 218A 318A 328A 118B 218B 318B 328B 49 12,2 97 23,9 141 39,5 264 81,2 58 16,7 116 31,6 169 44,8 331 50,5 m3/h dB(A) 17000 75 34000 78 51000 80 97800 83 15500 75 31000 78 46500 80 88800 83 mm mm mm kg 1880 800 1370 145 3230 800 1370 279 4580 800 1370 413 4580 800 1370 680 1880 800 1370 157 3230 800 1370 302 4580 800 1370 447 4580 800 1370 742 418B 428B 118C 218C 318C 328C 418C 428C 169 49,7 435 115 63 19,5 125 35,9 191 50,9 354 105 191 57,6 466 130 m3/h dB(A) 46500 80 118400 84 14400 75 28800 78 43200 80 81000 83 43200 80 108000 84 mm mm mm kg 4580 800 1370 447 5930 800 1370 982 1880 800 1370 168 4580 800 1370 324 4580 800 1370 481 5930 800 1370 804 5930 800 1370 481 5930 800 1370 1065 kW kW Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight kW kW Note: 1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C 2 Sound power on the basis of measurements made in compliance with ISO 3744. 3 Without legs kit configuration ; horizontal air flow 349 NCE/SL Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight 216A 218A 316A 318A 328A 418A 428A 216B 45 12,6 79 25,5 67 15,8 115 31,6 215 64,7 158 46 295 94,2 49 14,3 m3/h dB(A) 11600 68 24400 71 17400 70 36600 73 69600 76 48800 74 92800 77 10400 68 mm mm mm kg 2630 600 1230 150 3230 600 1230 279 3770 600 1230 221 4580 600 1230 413 4580 600 1230 680 5930 600 1230 547 4580 600 1230 900 2630 600 1230 166 318B 328B 418B 428B 528B 218C 328C 418C 133 40,4 259 71 182 51,7 340 106 430 115 95 28,9 273 80,5 190 57,6 m3/h dB(A) 33000 73 62400 76 44000 74 83200 77 104000 78 20200 71 57600 76 40400 74 mm mm mm kg 4580 600 1230 447 4580 600 1230 742 5930 600 1230 592 4580 600 1230 982 7280 600 1230 1222 3230 600 1230 324 4580 600 1230 804 5930 600 1230 637 kW kW Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight kW kW Note: 1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C 2 Sound power on the basis of measurements made in compliance with ISO 3744. 3 Without legs kit configuration ; horizontal air flow 350 351 altro FCE 218A÷828C Versioni B LN SL Remote condenser with axial fans 75,8 - 1088 kW Unit Description Remote condensers with axial-type fans for outdoor installation. Installation may be vertical with a horizontal air outflow or, using special brackets, horizontal with an upward air outflow. The very low noise, adjustable-speed fans are excellent for use for both industrial and commercial applications. 352 base version base version super-low noise version AXIAL r HFC R-134a FCE/B Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight 218A 228A 218B 228B 318B 328B 428B 518B 528B 78,8 22,9 150 42,7 98,1 28 182 48,6 123 30,9 237 61,5 386 103 259 70,8 894 231 m3/h dB(A) 42400 84 82400 87 39200 84 76000 87 58800 86 114000 89 152000 90 98000 88 190000 91 mm mm mm kg 3230 800 1370 279 3230 800 2390 462 3230 800 1370 302 3230 800 2390 502 4580 800 1370 447 4580 800 2390 742 5930 800 2390 982 7280 800 1370 737 7280 800 2390 1222 628B 828B 228C 328C 418C 428C 518C 528C 628C 534 137 755 204 203 56,2 329 87 219 59,4 440 121 293 78,4 506 130 572 140 228000 91 236800 94 70800 87 106200 89 73600 87 141600 90 92000 88 177000 91 212400 92 8630 800 2390 1461 11330 800 2390 1942 3230 800 2390 543 4580 800 2390 804 5930 800 1370 637 5930 800 2390 1065 7280 800 1370 794 7280 800 2390 1325 8630 800 2390 1585 kW kW Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight kW kW m3/h dB(A) mm mm mm kg Note: 1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C 2 Sound power on the basis of measurements made in compliance with ISO 3744. 3 Without legs kit configuration ; horizontal air flow FCE/LN Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight 218A 228A 328A 218B 228B 318B 328B 428B 518B 528B 77,1 23,6 147 44,2 220 69,3 95,3 29,2 177 50,6 120 32 265 78,5 374 107 252 74,3 436 121 m3/h dB(A) 34000 78 65200 81 97800 83 31000 78 59200 81 46500 80 88800 83 118400 84 77500 82 148000 85 mm mm mm kg 3230 800 1370 279 3230 800 2390 462 4580 800 2390 680 3230 800 1370 302 3230 800 2390 502 4580 800 1370 447 4580 800 2390 742 5930 800 2390 982 7280 800 1370 737 7280 800 2390 1222 kW kW Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight kW kW m3/h dB(A) mm mm mm kg 628B 828B 228C 328C 418C 428C 518C 528C 628C 521 143 732 213 197 59 318 92,3 214 62,9 423 129 283 82,5 489 137 556 147 177600 86 236800 88 54000 81 81000 83 57600 81 108000 84 72000 82 135000 85 162000 86 8630 800 2390 1461 11330 800 2390 1942 3230 800 2390 543 4580 800 2390 804 5930 800 1370 637 5930 800 2390 1065 7280 800 1370 794 7280 800 2390 1325 8630 800 2390 1585 Note: 1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C 2 Sound power on the basis of measurements made in compliance with ISO 3744. 3 Without legs kit configuration ; horizontal air flow 353 FCE/SL Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight 318A 416A 418A 428A 318B 328B 418B 428B 518B 528B 628B 94,8 29,4 75,8 24,2 131 39,4 252 74,3 114 34,7 215 62,5 148 43,6 287 80,7 196 59,2 274 107 433 124 m3/h dB(A) 36600 73 23200 71 48800 74 92800 77 33000 73 82200 76 44000 74 83200 77 55000 75 104000 78 124800 79 mm mm mm kg 4580 800 1370 413 4910 600 1230 292 5930 800 1370 547 5930 800 2390 900 4580 800 1370 447 4580 800 2390 742 5930 800 1370 592 5930 800 2390 982 7280 800 1370 737 7280 800 2390 1222 8630 800 2390 1461 kW kW Models NOMINAL CHARACTERISTICS Nominal capacity (1) Total power input (1) VENTILATION Air flow Sound power (2) SIZE L (3) P (3) H (3) Weight kW kW m3/h dB(A) mm mm mm kg 728B 828B 228C 328C 418C 428C 528C 628C 728C 828C 511 147 575 162 156 48 225 66,9 173 52,2 321 91 396 119 481 140 544 152 647 183 145600 79 1664000 80 38400 74 76200 76 40400 74 76800 77 96000 78 115200 79 134400 79 153600 80 9980 800 2390 1702 11330 800 2390 1942 3230 800 2390 543 4580 800 2390 804 5930 800 1370 637 5930 800 2390 1065 7280 800 2390 1325 8630 800 2390 1585 9980 800 2390 1845 11330 800 2390 2106 Note: 1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C 2 Sound power on the basis of measurements made in compliance with ISO 3744. 3 Without legs kit configuration ; horizontal air flow 354 355
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement