Z-Wave Electronic Radio-Frequency Receivers (1

Z-Wave Electronic Radio-Frequency Receivers (1
MAKING MODERN LIVING POSSIBLE
Z-Wave Electronic
Radio-Frequency Receivers
(1-Channel)
RZ1 and RZ1-HP
Danfoss Heating
Installation Guide
For a large print version of these instructions
please call Marketing on 0845 121 7400.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other
printed material. All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2
RZ1 and RZ1-HP
RZ1 and RZ1-HP
Z-Wave Electronic Radio Frequency Receiver
(1 Channel)
GB
Index
1.0
2.0
2.1
3.0
4.0
4.1
4.2
4.3
4.4
4.5
5.0
5.1
5.2
6.0
7.0
8.0
9.0
Specification................................................................................................ 4
Mounting Instructions............................................................................. 5
Wiring............................................................................................................. 6
Understanding your RZ1......................................................................... 7
Connecting devices to the RZ1............................................................. 8
Disconnecting devices from the RZ1.................................................. 9
Include devices to network, not using RZ1 relay output............. 9
Exclude devices from network, not using RZ1 relay output.....10
Including the RZ1 as a secondary controller to a network.......10
Excluding the RZ1 as a secondary controller to a network.......11
Implementing a network controller shift........................................12
Initiating a primary controller shift in an undefined
network using the RZ1...........................................................................12
Initiating a primary controller shift with the RZ1 being
promoted to the primary role.............................................................13
Using the protection capabilities.......................................................13
Factory Reset.............................................................................................14
Z-Wave supported and controlled classes......................................14
Glossary.......................................................................................................15
danfoss Heating
3
1.0 Specification
Radio Controlled Room Thermostat Receiver Module
RZ1
GB
Supply Voltage
Construction
RZ1-HP
230 Vac ± 15%, 50Hz
EN 60730-1, EN 300-220-1
Maximum Ambient
Temperature
Switch Type
Switch Rating
IP Rating
Control Pollution Situation
Max. Range
4
45°C
1 x SPDT, type 1B
230 Vac, 3 (1) A
(Total current)
230 Vac, 12 (6) A
(Total current)
IP 40
Degree 2
30 metres
Operating Frequency
868.42 MHz
Software Classification
Class A
Rated Impulse Voltage
2.5kV
Ball Pressure Test
75°C
RZ1 and RZ1-HP
2.0 Mounting Instructions
GB
danfoss Heating
5
2.1 Wiring RZ1
ELECTRONICS
GB
N L 1 2 3 4
COM
ZONE
1 ON
ZONE
1 OFF
Note: For mains voltage applications link terminals L and 2.
6
RZ1 and RZ1-HP
3.0 Understanding your RZ1
The RZ1 receiver unit uses a combination of coloured LEDs to indicate
the current operating mode/output status. For the purpose of this
document the indicator lights will be split into two distinct groups;
CHANNEL LEDs and PROGRAMME LED. More information is listed
below together with explanations of each of the LED colour states.
Programme
LED
Programme LED
Off
Green
Green (slow flash)
Red
Red (slow flash)
Orange
Orange (fast flash)
GB
Channel LED
Awaiting Bind/Unbind button press request
Normal Run Mode
Factory Reset State
Programme Mode
Binding/association in progress
Primary controller shift mode enabled
Failed to bind
Channel LED(s) - Programme Mode
Off
Channel Bound/Associated
Red
Channel not Bound/Associated
Red (slow flash)
Channel in process of being
bound/associated
Channel LED(s) - Run Mode
Off
Output OFF
Green
Output ON
Red
Channel not Bound
Red (fast flash)
Channel Bound but no communication
Red (slow flash)
Channel manually overridden to an OFF state
Green/Orange
Channel manually overridden to an ON state
(slow flash)
danfoss Heating
7
4.0 Connecting devices to the RZ1
To establish a connection with another Z-Wave enabled unit (i.e. RET
BZ), the RZ1 must be placed into its PROGRAMME MODE.
Once the RZ1 is in PROGRAMME MODE, each channel will present
whether it has an existing binding in the following way:
GB
Channel LED RED = unbound/no device present.
Channel LED OFF = Channel successfully bound/ device located and
communication established.
To establish communication and bind a device to the RZ1:
1.Press and release PROG button. The PROG LED will light up
RED.
2. Channels with no devices bound will show RED LED as well.
3.Press the button for the channel you wish to bind, the LED will
flash RED slowly.
4.Press the ‘include initiator’ button on the wireless device to be
connected to the RZ1 (On some devices you may need to press
and hold the include initiator button for up to 10 seconds).
5.Once binding has finished the LED for the channel just bound
will go out indicating success. If there was an error in the binding
process the PROG LED will flash ORANGE rapidly. If this occurs
acknowledge the error by pressing the PROG button and return
to step 1 to begin the process again.
6.Press PROG to return to normal operating mode (PROG LED
shows GREEN).
8
RZ1 and RZ1-HP
4.1 Disconnecting devices from the RZ1
Occasionally you may need to remove a thermostat or other Z-Wave
device from the RZ1 receiver. To do this, follow the procedure below:
1. Press PROG to set the RZ1 into PROGRAMME mode.
2.Press the button for the associated channel to be un-bound/
disconnected (RED channel LED will flash).
3.Press the ‘exclude initiator’ button on the device to be removed
(On some devices you may need to press and hold the include
initiator button for up to 10 seconds).
4.When the device has been removed, the RED LED for that
channel will illuminate continuously.
5. Press PROG to return to normal operating mode.
GB
4.2 Include devices to the network,
not using the RZ1 relay output
If you wish to include a device to the network but not use the relay
function of the RZ1, follow this procedure:
1.
2.
3.
4.
5.
6.
7.
Press the PROG button the PROG LED should turn RED.
Press the PROG button for at least 3 seconds or until the PROG
LED goes out.
Press and release within 3 seconds the PROG button, the PROG
LED should flash RED slowly indicating that an inclusion has
started.
Begin the inclusion process on your remote device.
If the process is successful the PROG LED will show solid RED.
Press PROG to return to normal operating mode.
If unsuccessful the PROG LED will flash ORANGE quickly. Press
the PROG button to return to step 1 and try again.
Once the inclusion is successfully completed, press the PROG
button to return to normal operating mode.
danfoss Heating
9
4.3 Exclude devices not using the RZ1 relay output from the network
If you wish to exclude a device from the network that does not use
the relay function of the RZ1, follow this procedure:
GB
1.
2.
3.
4.
5.
6.
7.
Press the PROG button, the PROG LED should turn RED.
Press the PROG button for at least 3 seconds or until the PROG
LED goes out.
Press the PROG button until the PROG LED flashes RED slowly
indication that exclusion has started.
Begin the exclusion process on your remote device.
If the process is successful the PROG LED will show solid RED.
Press PROG to return to normal operating mode.
If unsuccessful the PROG LED will flash ORANGE quickly. Press
the PROG button to return to step 1 and try again.
Once the exclusion is successfully completed, press the PROG
button to return to normal operating mode (PROG LED
GREEN).
4.4 Including the RZ1 as a secondary controller
to a network
If you already have a primary controller in the network and wish to
add the RZ1 as a secondary controller, follow the steps below: 1. Place the RZ1 into programme mode by pressing the PROG
button (Programme LED will turn RED)
2. Activate the include/bind initiator on the primary controller in
the network.
3. Press and hold the programme and channel buttons until the
RED LED flashes slowly indicating that inclusion as a secondary
controller has been started.
4. The RZ1 will attempt to connect to the network.
5. Once the RZ1 has successfully been incorporated into the
network, the programme LED will return to its continuously on
RED state.
10
RZ1 and RZ1-HP
6. If this process fails then the RZ1 PROG LED will flash ORANGE
fast. To acknowledge this press the PROG button. The LED will
return to RED, indicating that it has returned to programme
mode.
7. In the event of the RZ1 failing to join an existing network as a
secondary controller, the RZ1 will need to have its home and
node ID reset back to their default conditions by carrying out
a complete system reset by following the process laid out in
section 7.
GB
4.5 Excluding the RZ1 as a secondary controller to a network
To exclude your RZ1 from a network where it has been added as a
secondary controller, follow the steps below:
1. Place the RZ1 into programme mode by pressing the PROG
button (Programme LED will turn RED).
2. Activate the exclude/unbind initiator on the primary controller
in the network.
3. Press and hold the programme and channel buttons until the
RED LED flashes slowly indicating that exclusion as a secondary
controller has been initiated.
4. The RZ1 will attempt to unbind from the network.
5. Once the RZ1 has successfully been excluded from the network,
endpoint information and channel information will be removed
and the programme LED will return to its continuously on RED
state.
6. If a failure to exclude/unbind the RZ1 from the network occurs,
the programme LED will flash ORANGE fast. Acknowledge this
by pressing the programme button. Endpoint information and
channel information will be removed. And the channel LED will
return to a RED LED ON, indicating that it has returned to the
awaiting command programme mode.
danfoss Heating
11
5.0 Implementing a network controller shift
A network primary controller shift can not be started if:
1.
GB
2.
The RZ1/RZ1-HP has created the network and is the existing
primary, as it is the networks SIS by default.
The RZ1/RZ1-HP is a secondary network controller and not the
SUC and no other SIS is in the network.
If a user attempts to do a controller shift and points 1 and 2 apply the
process will fail automatically.
For the different methods of initiating a primary controller shift
please see the rest of section 5.
5.1 Initiating a primary controller shift in an
undefined network using RZ1
Should you wish to carry out a controller shift before a network has
been set-up this will be available by following the steps below:
1.
2.
3.
4.
5.
6.
7.
12
With the PROG LED flashing GREEN, push the PROG button for
at least 12 seconds.
The PROG LED will turn solid ORANGE to indicate that the
controller shift mode has been activated.
Press and release the CH1 button and the PROG LED will flash
RED slowly to indicate that a controller shift is occurring.
Start the inclusion process on the controller to be added to the
network as a replacement primary controller.
If the process is successful, the PROG LED will show solid RED,
failure will be indicated by the PROG LED flashing ORANGE.
To return to normal RUN mode, press the PROG button, the LED
will show GREEN.
If the process has failed, press and release the PROG button,
the PROG LED will show solid RED and the process can be
repeated.
RZ1 and RZ1-HP
5.2 Initiating a primary controller shift with the
RZ1 being promoted to the primary role
Should you wish to promote the RZ1 to the role of primary controller
in your network, do so by following the same process as for including
the RZ1 as a secondary controller in a network (See section 4.4).
GB
NOTE: It is the responsibility of the existing network controller to
initiate a controller shift, which the RZ1 will support.
6.0 Using the Protection Capabilities
This product supports the Z-Wave protection command class.
A device associated to an output relay on the RZ1 can use the
protection command class to:
• Stop a user from manually overriding a relay via the channel push
buttons using local protection.
• Stop another RF device controlling the relay via a wireless
command using RF exclusive protection.
danfoss Heating
13
7.0 Factory Reset
If for any reason you need to return the RZ1 unit to its factory reset
state, or you need to wipe all network information from the unit it is
advisable to perform a factory reset.
GB
1.Press PROG to place the receiver in PROGRAMME mode (Red
LED illuminated continuously).
2. Press and hold CH1 button for at least 15 seconds.
3.The PROG LED will flash rapidly orange and green. Press and
hold down the PROGRAMME button for at least 15 seconds.
4.If reset was successful, the channel LEDs will show as RED and
the PROG LED will flash slowly green to indicate that the unit is
now in its factory reset state.
* If after step 1, the PROG button is not held down within 30 seconds,
the unit will return to its previous state and the full reset will not have
been applied.
8.0 Z-Wave supported and controlled classes
14
Basic
Support
Binary switch
Support
Association
Control
Multi-Channel Vn2
Support
Multi-Channel Association Vn2
Control
Multi-command
Control and Support
Protection Vn2
Support
Version
Support
Wakeup
Control
Thermostat Set Point
Support
Manufacturers Specific
Support
RZ1 and RZ1-HP
9.0
Glossary
Binding
The act of linking a remote wireless unit (i.e.
thermostat or time controller) to the RZ1
receiver channel
Channel
The output of the RZ1 unit. RZ1 has one channel.
Each of these channels can be used to control a
device that requires switching on.
Include/Exclude
Initiator Button
On every Z-Wave product there will be a button
or process to tell the device to send out a request
to join or leave an existing or new network.
LED
Light Emitting Diode. The RZ1 has tri-colour
LEDs to indicate the different states the control
can be in.
Programme State
The RZ1 is ready to include or exclude other
Z-Wave compatible devices from the network.
Ready State
When the RZ1 is in ready state the GREEN
PROG LED is lit and the device is waiting for
instructions to switch on or off its output(s).
Reset State
In the Reset State the RZ1 is reset back to factory
defaults and is ready to either be added into
an existing network as a secondary controller
or to be used to create a network as a primary
controller.
Z-Wave
A wireless communication protocol designed
for low-power and low-bandwidth appliances,
such as home automation and sensor networks
SUC
(Static Update
Controller
A secondary controller that acts as a back up
store of the network routings. The SUC can be
used to create a new primary network controller
if commanded to, should the primary controller
malfunction. Only the primary controller can
include new devices with a SUC in the network
SIS
(SUC ID Server)
A SUC controller which has been promoted
by the network to become the ID server. Any
device in the network can include new nodes to
the network, not just the primary device.
danfoss Heating
GB
15
Danfoss Randall Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: [email protected]
Website: www.danfoss-randall.co.uk
Part No. RZ1v04_Installation