Montigo MD38-BV Installation & Operation Manual

Add to my manuals
14 Pages

advertisement

Montigo                     MD38-BV Installation & Operation Manual | Manualzz
Questions? Email us at [email protected] or visit our website at www.montigo.com.
Installation
Operation &
Maintenance
MD38-BV
Homefire
Modular
Gas Fireplace
Warning:
Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional
information consult a qualified installer,
service agency or the gas supplier.
What To Do If You Smell Gas:
For Your Safety:
Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
n
Check local codes and
read all instructions
prior to installation.
n
Leave this manual with
the owner.
MD38-BV Homefire
Table Of Contents
Introduction
About the M38 Series Modular Fireplaces:
Introduction ............................................................................. 2
Installation
Installing the Fireplace Shell ......................................... 3
Installing the Gasline ..................................................... 4
The Remote Switch ....................................................... 4
B-Vent Installation ......................................................... 4
Construction around the fireplace
Facing ............................................................... 5
Mantels and Surrounds ..................................... 5
Wiring ...................................................................... 5-6
Installing the Logset ...................................................... 6
Removing and Installing the Insert ................................ 7
Removing and Installing the Door ................................. 7
Operation .......................................................................... 8 - 10
Maintenance ................................................................... 10 - 11
Warranty ................................................................................. 12
Appendix
A. Accessories ............................................................ 13
The MD38-BV includes a 28,000 BTU dual burner and embers. All 38
Series Modular Fireplaces allow quick and easy upgrades in the future.
The MD38-BV can be upgraded to a Wildfire Burner. Contact your
dealer for more information. The MD38-BV model is available in two
versions:
nContinuous Pilot - (Product Code MD38B)
nIntermittent Pilot - (Product Code MD38B-I)
The MD38-BV is rated for Natural Gas at 28,000 BTU/H 8.5 Kilowatts)
Input or Propane at 28,000 BTU/H (8.5 Kilowatts) Input.
How to use this manual:
This manual covers all models and unless otherwise specified, the
designation MD38-BV refers to all models. Sections which are specific
to a particular model are marked with a symbol, plus the appropriate
model number.
Warranty and Installation Information:
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
n Modification of the fireplace and/or components including DirectVent assembly or glass doors.
n Use of any component part not manufactured or approved by
Montigo in combination with this Montigo fireplace system.
n Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements
for factory-built gas fireplaces. Installation & repairs should be done by
a qualified contractor.
Installations in Canada must conform to the current CAN/CGA B149.1 and .2 Gas Installation Code and local regulations. If the optional
air-circulating fan kit is installed, it must be electrically grounded in
accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or
Local Codes.
Installations in the USA must conform to local codes, or in the
absense of local codes to the National Fuel Gas Code, ANSI Z223.11988. If the optional air-circulating fan is installed, it must be grounded
in accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70-1987.
CAUTIONS
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
n Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
n Young children should be carefully supervised when
they are in the same room as the appliance.
n Clothing or other flammable materials should not be
placed on or near the appliance.
Page 2
MD38-BV Homefire
Installation
Installing The Fireplace Shell
The fireplace may be installed in any location that maintains proper
clearances to air conditioning ducts, electrical wiring and plumbing.
Safety, as well as efficiency of operation, must be considered when
selecting the fireplace location. Try to select a location that does not
interfere with room traffic, has adequate ventilation, and offers an
accessible pathway for B-Vent installation. Refer to page 4 - B-Vent
Installation for more information.
Unprotected combustible walls which are perpendicular to the
fireplace opening, must not project beyond the shaded area shown in
Figure 5b.
The fireplace dimensions are shown below:
Framing
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.
33
14 ¾
8½
C
Ø4" B-Vent
* When sheetrock is
not used behind the
fireplace, framing
depth may be
reduced to 14 3/4"
38
Top View
14 ¾
41 1/4
28 ¾
15 1/2
37 3/4
4¾
41
35
14 ½
35
Figure 2. Framing dimensions.
33 ½
0" clearance
to corners only
4¾
38
Figure 1.
Front View
Fireplace dimensions.
Side View
24 1/8
43 7/8
Clearances
The MD38-BV clearances to combustible materials are:
Top*
16"
Back
0"
Side
1 1/2"
Floor
0"
Mantle**
9"
B-Vent***
See Notes
* Clearance from the top of the fireplace to a
combustible ceiling within the fireplace
enclosure.
** Refer to page 5.
*** This model requires 2" clearance around the
B-Vent within the fireplace enclosure. Past the
enclosure, use standard clearance as specified
by the manufacturer of the B-Vent.
Figure 3. Corner framing dimensions.
Installing a Shelf Over the Fireplace
When installing a shelf over the top of the fireplace, the minimum
allowable clearance from the top of the fireplace to a shelf is
16".(Proper clearance must be maintained around the vent pipes, as
specified by the B-Vent manufacturer.)
WARNING:
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
Page 3
MD38-BV Homefire
Installation
Installing The Gas Line
The gas line must be installed before finishing the MD38-BV
Fireplace. Natural Gas requires a minimum inlet gas supply
pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane
Gas requires a minimum inlet gas supply pressure of 11" W.C. & a
manifold pressure of 10" W.C. Provision must also be made for a 1/8"
N.P.T. plugged tapping and be accessible for test gauge connection
immediately upstream of the gas supply controls to the appliance. The
fireplace gas connection and the main operating gas valve is located
behind the removable brass trim at the bottom of the unit and need
only be attached to the gas line with an approved fitting, as required
by the applicable installation codes.
1
2 1/2
Gasline access
6 x 2 1/2"
Figure 4. Gas line access.
The appliance and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than
1/2 psig (3.5 kPa).
Note: After gas line is connected, each appliance connection,
valve and valve train must be checked while under
normal operating pressure with either a liquid solution, or
leak detection device, to locate any source of leak. Tighten
any areas where bubbling appears or leak is detected until
bubbling stops completely or leak is no longer detected.
DO NOT use a flame of any kind to test for leaks.
Installing The Remote Switch
The MD38-BV's gas valve, located behind the lower brass trim, may
be connected to a wall switch. The valve generates its own power on
a millivolt circuit. Use only low voltage wire, and DO NOT connect
any external power to it.
Refer to Figure 26 for wiring requirements.
Note: The switch location must not exceed 30' from the fireplace.
Page 4
B-Vent Installation
The MD38-BV is certified for use with standard 4" B-Vent and
requires no B-Vent appliance connector. Simply attach the B-Vent to
the fireplace flue collar, and secure it using 1/4" sheet metal screws.
Do not penetrate the inner sleave of the B-Vent when tightening the
screws.
Refer to the current CAN/CGA B-149.1 and .2 or ANSI Z223.1-1988
Gas Installation Code for specific vent sizing.
CAUTION:
•
Test your B-Vent installation after completion to ensure that
no combustible by-products are spilling from the fireplace
opening. This draft test should be performed after a three(3)
minute warm up period. The manufacturer will not be
responsible for any installations with inadequate draw.
MD38-BV Homefire
Installation
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in Figure 5a. Side wall clearances are 3".
Combustible surrounds may be installed with 3" clearance to the side
of the fireplace as shown in Figure 5b.
Painting:
Special care is recommended by the Master Painters and Decorators
Association, when painting the fireplace surrounds, to select and
apply a quality Alkyd sealer prior to the applying of latex paints. This
is to prevent leaching of water from evaporation and causing a
brownish staining effect to paint over coats.
Fireplace Facing
Sheetrock/
Drywall
Header
When selecting the finish material for your fireplace, it is important to
remember the following: BRASS TRIMS MUST NOT BE
OBSTRUCTED IN ANY WAY - to do so restricts the air supply for
the control compartments and heat exchanger it also prevents
access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.
45
3
Combustible construction
allowed in shaded area.
Combustible Facing
Figure 5b. Combustible surrounds.
Wiring
Gas Control and Pilot Wiring
MD38-BV-I
Top of fireplace
Honeywell (Q3450)
Pilot Assembly
12 11 10 9 8 7 6 5 4 3 2 1
Pilot Electrical
Harness Connector
Figure 5a. Combustible mantles and facings.
Honeywell Gas
Control (SV9501M)
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
Gas Control
Connector
Fuse
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Fan Plug
Receptacle
Please be aware; temperatures over the mantel will rise above
normal room temperature and walls above fireplace may be hot to
touch.
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause
melting, deformation, discoloration or premature failure of T.V. and
radio components.
Junction Box Cover
Junction Box
Black
White
Green
115VAC
24VAC
Grnd Screw
40 VA
Transformer
Limit
Switch
Wall
Switch
Figure 6. Wiring for the MD38-BV-I with Honeywell gas control and
pilot.
Page 5
MD38-BV Homefire
Installation
Wiring for the optional Fan Kit
3.
All 38 Series Modular fireplaces may be equipped with optional fan or
blower kits for circulating heat into the living space.
Place the Front log onto the front log rest as shown in figure 8a.
Centre the log from side to side, and push it against the back of
the log rest. Carefully push the log onto the metal spikes on the log rest.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70-1987.
Log 'A'
For more information see the Fan Kit Installation Guide included
with the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
L1-WH
G L2-BLK
Figure 8a. Positioning for the front and back logs.
Quick Connect
plug to motor
4.
Place the top logs in position as shown in figure 8b, place the
centre log down first, then the right and left logs.
5.
Start
Logthe
'D'fireplace. If the flame appears
Log 'E' satisfactory, replace the
glass door and door cover.
Figure 7a. Wiring for optional air circulating fan kit.
115/1/60 Supply
G L1 L2
Embers
Figure 7b. Wiring schematic for optional fan kit.
Figure 8b. Proper log placement.
Installing the Log Set
Installing the Logs:
The MD38-BV is supplied with five ceramic fibre logs. Unpack the logs
and handle them very carefully.
1.
Remove the door cover and the glass door.
2.
Place the Back log onto the back log rest as shown below in figure
8a. The log has lip on the bottom which fits into the slot on the log rest.
Page 6
Flame Shaper
NOTES:
n If logs are not placed properly, excessive sooting will result.
n The surface of the logs will crack due to the heat from the
flames. This is a normal occurance.
MD38-BV Homefire
Installation
Removing and Installing
the Insert
Removing and Installing
the Door
You may remove the insert to protect it from theft and damage
during construction.
Removing the door surround:
1. Remove the two machine screws (1 left & 1 right) at the top of the
insert that attach the insert to the shell. See Inset 1.
2. Remove the fresh air flex from the collars on the shell. See Figure
9. Important: Be careful not to damage the fresh air flex
during removal or storage.
The door surround is held in place by two metal clips at the top, and
one magnet on each side. To remove the surround, pull the bottom
outwards and lift upwards until the slots "A" are clear of tabs "B" in the
door. You may need to use a flat screwdriver to pull the door surround
outwards. (See figure 11a).
Slot 'A'
Tab 'B'
3. Remove the 4 machine screws that hold the venting plate to the
insert.
Door surround
4. Remove the insert by tipping the top of the insert outward and
lifting the tabs past the slots in the bottom of the shell. See Inset
2.
Store the screws and clamps in a safe place to ensure that they are
not lost.
Glass door
and frame
Magnet
To re-install the insert simply reverse the steps above.
Mounting
Bracket
Pull bottom of
door surround
outwards and
upwards.
Tab
Figure 11a. Removing or installing the door surround.
INSET 1
INSET 2
Front
Slot
Removing the door:
Remove the machine screws along the top of the door, and then pull
the door outwards and upwards until it is clear of the door rail. (See
figure 11b). Ensure that a good seal is maintained when installing the
door.
High temp.
silicone seal
Fresh Air
Flex (4" dia.)
Venting Plate
Figure 9. MD38-BV insert.
Glass door
& frame
Figure 11b. Removing or installing the glass door.
Page 7
MD38-BV Homefire
MD38-BV
Operation - Model MD38-BV
with Continuous Pilot
For Your Safety - READ BEFORE LIGHTING:
WARNING:
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
n If you cannot reach your gas supplier, call the Fire
Department.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas:
n Do not try to light any appliance.
n Do not touch any electrical switch; do not use any
phone in your building.
n Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service technician.
Force or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
Lighting Instructions:
1. STOP! Read the safety information above on this label.
2. Flip down lower trims.
3. Push in gas control knob and turn clockwise
to
"OFF."
4. Wait five (5) minutes to clear out any gas. Smell for gas,
including near the floor. If you then smell gas, STOP!
Follow "B" in the safety information above on this label. If
you don't smell gas, go to the next step.
5. Locate pilot burner (See illustration at right.) and follow
steps below.
to
6. Turn knob on gas control counterclockwise
"PILOT."
Gas Control Knob
(Shown in "Pilot" postion.)
7. Push in gas control knob completely and hold. Light with
Piezo Igniter button. Continue to hold the control knob in for
about (1) minute after the pilot is lit. Release the knob and it
will pop back up. Pilot should remain lit. If it goes out repeat
steps 3 through 8.
n If knob does not pop up when released. Stop and
immediately call your service technician or gas supplier.
n If the pilot will not stay lit after
several tries, turn the gas
control knob to "OFF" and
call your service technician
or gas supplier.
8. Push in gas control knob and
to "ON."
turn counterclockwise
9. Flip up lower trim.
10.Turn on remote switch to ignite fire.
NOTE: Knob cannot be turned from
"PILOT" to "OFF" unless knob is
pushed in slightly. Do not force.
To Turn Off Gas To Appliance:
1. Turn off remote switch.
2. Flip down lower trim.
Page 8
3. Push in gas control knob slightly and turn
to "Off". Do not force.
4. Flip up lower Trim.
clockwise
MD38-BV Homefire
MD38-BV-I
Operation - Model MD38-BV-I
with Honeywell Intermittent Pilot
For Your Safety - READ BEFORE LIGHTING:
WARNING:
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an ignition system that
lights the pilot burner automatically. Do not attempt to
light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
What To Do If You Smell Gas:
n Do not try to light any appliance.
n Do not touch any electrical switch; do not use any
phone in your building.
n Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
n If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service
technician. Force or attempt to repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system,
and any gas control which has been under water.
Lighting Instructions:
1. STOP! Read the safety information above on this label.
8. If the fireplace does not operate, follow the instructions "To
Turn Off Gas To Appliance" and call your service
technician or gas supplier.
2. Flip down lower trims.
3. Turn switch on the gas control to OFF".
4. Wait 5 minutes to clear out any gas. If you smell gas,
STOP! Follow "B" in the safety information above on this
label. If you don't smell gas, go to the next step.
5. Turn switch on the gas control to "ON". NOTE: This unit is
equipped with an ignition system that lights the pilot burner
Gas
Inlet
automatically. Do not attempt to light the pilot by hand.
6. Turn on wall switch.
7. Flip up lower trim.
Gas Control Switch
Shown in "On" Position
To Turn Off Gas To Appliance:
1. Turn off remote switch.
3. Turn the switch on the gas control to "Off".
2. Flip down lower trim.
4. Flip up lower trim.
Page 9
MD38-BV Homefire
Operation
Maintenance
Lighting Instructions
CAUTIONS
n Fireplace gas control must be in the “OFF” position and pilot
and main burners extinguished when cleaning appliance with
a vacuum.
See pages 8 and 9.
Burner Adjustment
The MD38-BV fireplace is equipped with an adjustable burner,
allowing you to raise or lower the flames. Operating the control
knob as described below will adjust both the main burner and the
ember burner.
n
To raise the flame height, turn the black knob (located behind
the lower trim) counterclockwise.
n
To lower the flame height, turn clockwise.
'Hi-Lo' Adjustment Knob
n Doors and logs can get very hot. Handle only when cool.
General
n Have the fireplace installation inspected yearly, including a visual
check of the vent system, the burner and the pilot flame. For your
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 26.
n For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
n For Propane Gas this appliance requires a minimum inlet
pressure of 11" W.C. and a manifold pressure of 10" W.C.
n Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours and
liquids.
n Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
Gas Control Knob
(Shown in "Pilot" postion.)
Figure 11. 'Hi-Lo' Adjustment on the MD38-BV's gas valve.
Cleaning
When the fireplace is first activated, there may be some smoking and
a visible film may be left on the glass. This is a normal condition, and
is the result of burning of protective coatings on new metal.
n Glass must be cleaned periodically to remove any film (which is a
normal biproduct of combustion) which may be visible. Film can
easily be removed by removing the door, as shown on page 7.
Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.
n Silicone seals on inner door during initial firing will "off gas",
leaving a visual deposit of a white substance on combustion
chamber walls. This can easily be removed using normal
household products.
n Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.
n Logs may be cleaned periodically with a vacuum to remove soot
or other contaminates.
WARNING:
Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass
etching may cause premature glass failure.
Page 10
MD38-BV Homefire
Maintenance
Troubleshooting
Gas Control Valve
HONEYWELL SV 9500 /SV9600
Troubleshooting Sequence
Power
Generator
Pilot Adjustment Screw
Wall Switch
NOTE: Before Troubleshooting, Familiarize Yourself With
START
The Startup And Checkout Procedure.
INSET
· Turn Gas Supply off
· Set thermostat to
call for heat
Inlet
Pressure
SV9500/SV9600
is powered
(24 VAC nominal)
Manifold Pressure
Test Connection
NO
Figure 12. Sit Nova 820 gas valve.
YES
Pilot Burner Adjustment
1. Locate Pilot Adjustment Screw. (See figure 12.)
2. Adjust pilot screw to provide properly sized flame as shown in
figure 13).
3. After installing or servicing, leak test with a soap solution with
main burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.
NO
Igniter warms up
and glows red.
Pilot Valve opens.
YES
Turn gas on.
Pilot Burner lights?
Main Valve opens?
Troubleshooting
The following is a troubleshooting chart of possible problems:
PROBLEM
Noisy Pilot Flame
Pilot won’t ignite
Main burner will
not light
YES
MD38-BV
CORRECTIVE ACTION
Locate pilot adjustement screw on gas
control valve. Flame is decreased by
turning adjustment screw clockwise.
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram figure 12.
SYSTEM OK
CHECK:
HSI
· Line voltage power
Terminals
· Low voltage transformer
· Limit Controller
· Thermostat
· Wiring
· Air proving switch on
combustion air blower system
· Vent damper (if used) is open
and end switch made
Unplug Pilot Burner Cable,
Measure Voltage at
SV9500/SV9600 HSI
Terminals (24 VAC
Nominal, See INSET)
NO
Replace
SV9500/
SV9600
YES
NO
Replace Igniter/
Flame Rod Assembly.
Replace SV9500/SV9600
NO
Measure Voltage to SV9500
/SV9600. Voltage must
be at least 19.5 VAC
NO
YES
YES
Figure 13. Pilot Burner
MD38-BV-I
Check
Transformer
Line Volt
Supply
Replace Igniter/
Flame Rod Assembly.
NO
Replace Igniter/Flame
Rod Assembly and retain.
Restart Troubleshooting
Sequence. Does main
valve open?
YES
NO
Replace
SV9500/
SV9600.
Save old
Igniter/Flame
Rod Assembly
for service.
Discard old Igniter/
Flame Rod Assembly.
If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
agency.
All spare parts, optional fans, and optional trim finishes are available
from your local dealer or the manufacturer.
1. Check wiring (see figure 12).
2. Check wall switch for proper
connection.
Page 11
MD38-BV Homefire
Warranty
The W
arranty
Warranty
The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a
ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and
fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
Remedy And Exclusions
The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation
outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, and
will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies will,
at its option, refund the purchase price of the Montigo Gas Appliance.
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which
are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All
replacement or repair components will be shipped F.O.B. the nearest The Companies factory.
Qualifications To The Warranty
The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)
The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas
Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appliance
could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building
codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies
(2)
The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such
as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.
Limitations On Liability
It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty,
expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs or
is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect
to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the
above may not apply to you.
Investigation Of Claims Against Warranty
The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.
How T
o Register A Claim Against W
arranty
To
Warranty
In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably possible
after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.
Other Rights
This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
NOTE:
The Companies as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.
Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without
notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Page 12
MD38-BV Homefire
Appendix A - Accessories
1
2
3
Available Options and Accessories:
1. Add-on Bay Window
2. Hand-Held Remote Control
3. Variable Speed Blower Kit
4. 4-Fan Kit
5. 4-Piece Picture Frame Surround (PFS)
6. 3-Piece Picture Frame Surround (PFO)
7. Door Cover, Square (DF0)
8. Door Cover, Arched (DFA)
9. Horizontal Trim Kits (Black, Brass, Nickel)
10. Replacement Logset
4
6
9
5
8
7
10
Page 13
XG0309 Rev. 2 - 09/00
Canadian Heating Products Inc.
Montigo Del Ray Corp.
Langley, BC V4W 4A1
Ferndale, WA 98248

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement