B A P P E N D I X Connector and Cable Specifications Connector Specifications • 10/100/1000 Ports, page B-1 • 10 Gigabit Ethernet CX1 (SFP+ Copper) Connectors, page B-2 • SFP and SFP+ Modules, page B-2 • 10/100 Ethernet Management Port, page B-3 • Console Port, page B-4 10/100/1000 Ports The 10/100/1000 Ethernet ports on switches use RJ-45 connectors and Ethernet pinouts. 10/100/1000 Port Pinouts Pin Label 1 TP0+ 2 TP0- 3 TP1+ 4 TP2+ 5 TP2- 6 TP1- 7 TP3+ 8 TP3- 1 2 3 4 5 6 7 8 60915 Figure B-1 Catalyst 3750-X and 3560-X Switch Hardware Installation Guide OL-19593-03 B-1 Appendix B Connector and Cable Specifications Connector Specifications 10 Gigabit Ethernet CX1 (SFP+ Copper) Connectors The 10-Gigabit Ethernet electrical modules use CX1 copper connectors similar to the one shown in Figure B-2. Note When ordering or using CX1 cables, ensure that the version identifier is 2 or higher. The 10-Gigabit Ethernet optical modules use the connectors shown in Figure B-3 and Figure B-4. 10-Gigabit Ethernet CX1 Copper Connector (example) 278541 Figure B-2 SFP and SFP+ Modules Figure B-3, Figure B-4, and Figure B-5 show the SFP module connectors. The Catalyst 3560-X switch supports the SFP module patch cable, a 0.5-meter, copper, passive cable with SFP module connectors at each end (Figure B-6). This cable can be used (only with 1-Gigabit Ethernet SFP ports) to connect two Catalyst 3560-X switches in a cascaded configuration. Duplex LC Cable Connector 58476 Figure B-3 Catalyst 3750-X and 3560-X Switch Hardware Installation Guide B-2 OL-19593-03 Appendix B Connector and Cable Specifications Connector Specifications Simplex LC Cable Connector Figure B-5 Copper SFP Module RJ-45 Connector 57834 Figure B-4 Label 1 TP0+ 2 TP0- 3 TP1+ 4 TP2+ 5 TP2- 6 TP1- 7 TP3+ 8 TP3- SFP Module Patch Cable (Catalyst 3560-X Switches) 126809 Figure B-6 1 2 3 4 5 6 7 8 60915 Pin 10/100 Ethernet Management Port The 10/100 Ethernet management port uses RJ-45 connectors with Ethernet pinouts. Figure B-7 shows the pinouts. Catalyst 3750-X and 3560-X Switch Hardware Installation Guide OL-19593-03 B-3 Appendix B Connector and Cable Specifications Connector Specifications 10/100 Port Pinouts Pin Label 1 RD+ 2 RD- 3 TD+ 4 NC 5 NC 6 TD- 7 NC 8 NC 1 2 3 4 5 6 7 8 H5318 Figure B-7 Console Port The switch has two console ports: a USB 5-pin mini-Type B port on the front panel (see Figure B-8) and an RJ-45 console port on the rear panel. USB Mini-Type B Port 253163 Figure B-8 The USB console port uses a USB Type A to 5-pin mini-Type B cable, shown in Figure B-9. The USB Type A-to-USB mini-Type B cable is not supplied. You can order an accessory kit (part number 800-33434) that contains this cable. USB Type A-to-USB 5-Pin Mini-Type B Cable 253405 Figure B-9 The RJ-45 console port uses an 8-pin RJ-45 connector (See Table B-2 and Table B-3.) The supplied RJ-45-to-DB-9 adapter cable is used to connect the console port of the switch to a console PC. You need to provide a RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter. For console port and adapter pinout information, see Table B-2 and Table B-3. Catalyst 3750-X and 3560-X Switch Hardware Installation Guide B-4 OL-19593-03 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Cable and Adapter Specifications • SFP and SFP+ Module Cable Specifications, page B-5 • Four Twisted-Pair Cable Pinouts, page B-7 • Two Twisted-Pair Cable Pinouts, page B-7 • Identifying a Crossover Cable, page B-8 • Console Port Adapter Pinouts, page B-9 SFP and SFP+ Module Cable Specifications Each port must match the wave-length specifications on each end of the cable, and the cable must not exceed the stipulated cable length. Copper 1000BASE-T SFP module transceivers use standard four twisted-pair, Category 5 cable at lengths up to 328 feet (100 meters). Table B-1 Fiber-Optic SFP and SFP+ Module Port Cabling Specifications Core Size/Cladding Size (micron) Modal Bandwidth (MHz/km)1 Cable Distance MMF 50/125 62.5/125 500 500 6,562 feet (2 km) 6,562 feet (2 km) 1490 TX 1310 RX SMF G.6522 — 32,810 feet (10 km) 1000BASE-BX10-U (GLC-BX-U) 1310 TX 1490 RX SMF G.6522 — 32,810 feet (10 km) 1000BASE-SX (GLC-SX-MM, GLC-SX-MMD) 850 MMF 62.5/125 62.5/125 50/125 50/125 160 200 400 500 722 feet (220 m) 902 feet (275 m) 1,640 feet (500 m) 1,804 feet (550 m) 1000BASE-T (GLC-T) Standard 4 twisted-pair Category 5 cable — — — 328 feet (100 m) 1000BASE-LX/LH (GLC-LH-SM, GLC-LH-SMD) 1310 MMF3 SMF 62.5/125 50/125 50/125 G.6522 500 400 500 — 1,804 feet (550 m) 1,804 feet (550 m) 1,804 feet (550 m) 32,810 feet (10 km) Wavelength (nanometers) Cable Type 100BASE-FX (GLC-GE-100FX) 1310 1000BASE-BX10-D (GLC-BX-D) SFP Module 1000BASE-ZX (GLC-ZX-SM) 1550 SMF G.6522 — 43.4 to 62 miles (70 to 100 km)4 CWDM-SFP-xxxx 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 SMF G.6522 — 62 miles (100 km) Catalyst 3750-X and 3560-X Switch Hardware Installation Guide OL-19593-03 B-5 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Table B-1 Fiber-Optic SFP and SFP+ Module Port Cabling Specifications (continued) Wavelength (nanometers) SFP Module Cable Type Core Size/Cladding Size (micron) 2 Modal Bandwidth (MHz/km)1 Cable Distance — 62 miles (100 km) DWDM-SFP-xxxx 1560.61, 1561.42, 1559.79, 1558.98, 1558.17, 1557.36, 1556.55, 1555.75, 1554.94, 1554.13, 1552.52, 1553.33, 1551.72, 1550.92, 1550.12, 1549.32, 1548.51, 1547.72, 1546.92, 1546.12, 1545.32, 1544.53, 1543.73, 1542.94, 1542.14, 1541.35, 1540.56, 1539.77, 1538.98, 1538.19, 1537.40, 1536.61, 1535.82, 1535.04, 1534.25, 1533.47, 1532.68, 1531.90, 1531.12, 1530.33 SMF G.652 10GBASE-LR (SFP-10G-LR) 1310 SMF G.6522 10GBASE-SR (SFP-10G-SR) 850 MMF 62.5/125 62.5/125 50/125 50/125 50/125 160 200 400 500 2000 85 feet (26 m) 108 feet (33 m) 216 feet (66 m) 269 feet (82 m) 6,561 feet (2000 m) 10GBASE-LRM (SFP-10G-LRM) 1310 MMF 62.5/125 50/125 50/125 500 400 500 722 feet (220 m) 328 feet (100 m) 722 feet (220 m) SMF G.6522 — 984 feet (300 m) — — 10GBASE-CX1 — 6.21 miles (10 km) (SFP-H10GB-CU1M) Twinax cable, 30-AWG cable assembly 3 feet (1 m) (SFP-H10GB-CU3M) Twinax cable, 30-AWG cable assembly 9 feet (3 m) (SFP-H10GB-CU5M) Twinax cable, 24-AWG cable assembly 16 feet (5 m) 1. Modal bandwidth applies only to multimode fiber. 2. A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers. 3. A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF or 1000BASE-LX/LH SFP modules and a short link distance can cause transceiver saturation and an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link distances greater than 984 feet (300 m). Catalyst 3750-X and 3560-X Switch Hardware Installation Guide B-6 OL-19593-03 Appendix B Connector and Cable Specifications Cable and Adapter Specifications 4. 1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on the fiber quality, the number of splices, and the connectors. Four Twisted-Pair Cable Pinouts Router or PC 1 TPO+ 1 TP1+ 2 TPO- 2 TP1- 3 TP1+ 3 TPO+ 6 TP1- 6 TPO- 4 TP2+ 4 TP3+ 5 TP2- 5 TP3- 7 TP3+ 7 TP2+ 8 TP3- 8 TP2- Figure B-11 65272 Switch Four Twisted-Pair Straight-Through Cable Schematic Four Twisted-Pair Crossover Cable Schematic Switch Switch 1 TP0+ 1 TP0+ 2 TP0- 2 TP0- 3 TP1+ 3 TP1+ 6 TP1- 6 TP1- 4 TP2+ 4 TP2+ 5 TP2- 5 TP2- 7 TP3+ 7 TP3+ 8 TP3- 8 TP3- 65274 Figure B-10 Two Twisted-Pair Cable Pinouts Two Twisted-Pair Straight-Through Cable Schematic Switch Router or PC 3 TD+ 6 TD– 3 RD+ 6 RD– 1 RD+ 2 RD– 1 TD+ 2 TD– H5578 Figure B-12 Catalyst 3750-X and 3560-X Switch Hardware Installation Guide OL-19593-03 B-7 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Two Twisted-Pair Crossover Cable Schematic Switch Switch 3 TD+ 6 TD– 3 TD+ 6 TD– 1 RD+ 2 RD– 1 RD+ 2 RD– H5579 Figure B-13 Identifying a Crossover Cable TYou can identify a crossover cable by comparing the two modular ends of the cable. Hold the cables side-by-side with the tab at the back. The first (far left) colored wire (pin 1) at one end of the cable is the third colored wire (pin 3) at the other end of the cable. The second colored wire (pin 2) at one end of the cable is the sixth colored wire (pin 6) at the other end of the cable. See Figure B-14. Figure B-14 Crossover Cable 1 2 3 4 5 6 7 8 127839 1 2 3 4 5 6 7 8 Catalyst 3750-X and 3560-X Switch Hardware Installation Guide B-8 OL-19593-03 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Figure B-15 RJ-45 Crossover Cable Identification Pin 1 Pin 2 Pin 3 62741 Pin 6 Console Port Adapter Pinouts The console port uses an 8-pin RJ-45 connector, which is described in Table B-2 and Table B-3. If you did not order a console cable, you need to provide an RJ-45-to-DB-9 adapter cable to connect the switch console port to a PC console port. You need to provide an RF-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order a kit with an adapter (part number ACS-DSBUASYN=). For console port and adapter pinout information, see Table B-2 and Table B-3. Table B-2 lists the pinouts for the console port, the RF-45-to-DB-9 adapter cable, and the console device. Table B-2 Console Port Signaling Using a DB-9 Adapter Switch Console Port (DTE) RJ-45-to-DB-9 Terminal Adapter Console Device Signal DB-9 Pin Signal RTS 8 CTS No connection 6 DSR TxD 2 RxD GND 5 GND GND 5 GND RxD 3 TxD No connection 4 DTR CTS 7 RTS Table B-3 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE adapter, and the console device. Note The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You can order a kit with the adapter (part number ACS-DSBUASYN=) from Cisco. Catalyst 3750-X and 3560-X Switch Hardware Installation Guide OL-19593-03 B-9 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Table B-3 Console Port Signaling Using a DB-25 Adapter Switch Console Port (DTE) RJ-45-to-DB-25 Terminal Adapter Console Device Signal DB-25 Pin Signal RTS 5 CTS No connection 6 DSR TxD 3 RxD GND 7 GND GND 7 GND RxD 2 TxD No connection 20 DTR CTS 4 RTS Catalyst 3750-X and 3560-X Switch Hardware Installation Guide B-10 OL-19593-03
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement