B Connector and Cable Specifications Connector Specifications

B Connector and Cable Specifications Connector Specifications
B
A P P E N D I X
Connector and Cable Specifications
Connector Specifications
•
10/100/1000 Ports, page B-1
•
10 Gigabit Ethernet CX1 (SFP+ Copper) Connectors, page B-2
•
SFP and SFP+ Modules, page B-2
•
10/100 Ethernet Management Port, page B-3
•
Console Port, page B-4
10/100/1000 Ports
The 10/100/1000 Ethernet ports on switches use RJ-45 connectors and Ethernet pinouts.
10/100/1000 Port Pinouts
Pin
Label
1
TP0+
2
TP0-
3
TP1+
4
TP2+
5
TP2-
6
TP1-
7
TP3+
8
TP3-
1 2 3 4 5 6 7 8
60915
Figure B-1
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
OL-19593-03
B-1
Appendix B
Connector and Cable Specifications
Connector Specifications
10 Gigabit Ethernet CX1 (SFP+ Copper) Connectors
The 10-Gigabit Ethernet electrical modules use CX1 copper connectors similar to the one shown in
Figure B-2.
Note
When ordering or using CX1 cables, ensure that the version identifier is 2 or higher.
The 10-Gigabit Ethernet optical modules use the connectors shown in Figure B-3 and Figure B-4.
10-Gigabit Ethernet CX1 Copper Connector (example)
278541
Figure B-2
SFP and SFP+ Modules
Figure B-3, Figure B-4, and Figure B-5 show the SFP module connectors.
The Catalyst 3560-X switch supports the SFP module patch cable, a 0.5-meter, copper, passive cable
with SFP module connectors at each end (Figure B-6). This cable can be used (only with 1-Gigabit
Ethernet SFP ports) to connect two Catalyst 3560-X switches in a cascaded configuration.
Duplex LC Cable Connector
58476
Figure B-3
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
B-2
OL-19593-03
Appendix B
Connector and Cable Specifications
Connector Specifications
Simplex LC Cable Connector
Figure B-5
Copper SFP Module RJ-45 Connector
57834
Figure B-4
Label
1
TP0+
2
TP0-
3
TP1+
4
TP2+
5
TP2-
6
TP1-
7
TP3+
8
TP3-
SFP Module Patch Cable (Catalyst 3560-X Switches)
126809
Figure B-6
1 2 3 4 5 6 7 8
60915
Pin
10/100 Ethernet Management Port
The 10/100 Ethernet management port uses RJ-45 connectors with Ethernet pinouts. Figure B-7 shows
the pinouts.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
OL-19593-03
B-3
Appendix B
Connector and Cable Specifications
Connector Specifications
10/100 Port Pinouts
Pin
Label
1
RD+
2
RD-
3
TD+
4
NC
5
NC
6
TD-
7
NC
8
NC
1 2 3 4 5 6 7 8
H5318
Figure B-7
Console Port
The switch has two console ports: a USB 5-pin mini-Type B port on the front panel (see Figure B-8) and
an RJ-45 console port on the rear panel.
USB Mini-Type B Port
253163
Figure B-8
The USB console port uses a USB Type A to 5-pin mini-Type B cable, shown in Figure B-9. The USB
Type A-to-USB mini-Type B cable is not supplied. You can order an accessory kit (part
number 800-33434) that contains this cable.
USB Type A-to-USB 5-Pin Mini-Type B Cable
253405
Figure B-9
The RJ-45 console port uses an 8-pin RJ-45 connector (See Table B-2 and Table B-3.) The supplied
RJ-45-to-DB-9 adapter cable is used to connect the console port of the switch to a console PC. You need
to provide a RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a
terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter. For console port
and adapter pinout information, see Table B-2 and Table B-3.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
B-4
OL-19593-03
Appendix B
Connector and Cable Specifications
Cable and Adapter Specifications
Cable and Adapter Specifications
•
SFP and SFP+ Module Cable Specifications, page B-5
•
Four Twisted-Pair Cable Pinouts, page B-7
•
Two Twisted-Pair Cable Pinouts, page B-7
•
Identifying a Crossover Cable, page B-8
•
Console Port Adapter Pinouts, page B-9
SFP and SFP+ Module Cable Specifications
Each port must match the wave-length specifications on each end of the cable, and the cable must not
exceed the stipulated cable length. Copper 1000BASE-T SFP module transceivers use standard four
twisted-pair, Category 5 cable at lengths up to 328 feet (100 meters).
Table B-1
Fiber-Optic SFP and SFP+ Module Port Cabling Specifications
Core
Size/Cladding
Size (micron)
Modal
Bandwidth
(MHz/km)1
Cable Distance
MMF
50/125
62.5/125
500
500
6,562 feet (2 km)
6,562 feet (2 km)
1490 TX
1310 RX
SMF
G.6522
—
32,810 feet (10 km)
1000BASE-BX10-U
(GLC-BX-U)
1310 TX
1490 RX
SMF
G.6522
—
32,810 feet (10 km)
1000BASE-SX
(GLC-SX-MM,
GLC-SX-MMD)
850
MMF
62.5/125
62.5/125
50/125
50/125
160
200
400
500
722 feet (220 m)
902 feet (275 m)
1,640 feet (500 m)
1,804 feet (550 m)
1000BASE-T
(GLC-T)
Standard 4
twisted-pair
Category 5 cable
—
—
—
328 feet (100 m)
1000BASE-LX/LH
(GLC-LH-SM,
GLC-LH-SMD)
1310
MMF3
SMF
62.5/125
50/125
50/125
G.6522
500
400
500
—
1,804 feet (550 m)
1,804 feet (550 m)
1,804 feet (550 m)
32,810 feet (10 km)
Wavelength
(nanometers)
Cable Type
100BASE-FX
(GLC-GE-100FX)
1310
1000BASE-BX10-D
(GLC-BX-D)
SFP Module
1000BASE-ZX
(GLC-ZX-SM)
1550
SMF
G.6522
—
43.4 to 62 miles
(70 to 100 km)4
CWDM-SFP-xxxx
1470, 1490, 1510,
1530, 1550, 1570,
1590, 1610
SMF
G.6522
—
62 miles (100 km)
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
OL-19593-03
B-5
Appendix B
Connector and Cable Specifications
Cable and Adapter Specifications
Table B-1
Fiber-Optic SFP and SFP+ Module Port Cabling Specifications (continued)
Wavelength
(nanometers)
SFP Module
Cable Type
Core
Size/Cladding
Size (micron)
2
Modal
Bandwidth
(MHz/km)1
Cable Distance
—
62 miles (100 km)
DWDM-SFP-xxxx
1560.61, 1561.42,
1559.79, 1558.98,
1558.17, 1557.36,
1556.55, 1555.75,
1554.94, 1554.13,
1552.52, 1553.33,
1551.72, 1550.92,
1550.12, 1549.32,
1548.51, 1547.72,
1546.92, 1546.12,
1545.32, 1544.53,
1543.73, 1542.94,
1542.14, 1541.35,
1540.56, 1539.77,
1538.98, 1538.19,
1537.40, 1536.61,
1535.82, 1535.04,
1534.25, 1533.47,
1532.68, 1531.90,
1531.12, 1530.33
SMF
G.652
10GBASE-LR
(SFP-10G-LR)
1310
SMF
G.6522
10GBASE-SR
(SFP-10G-SR)
850
MMF
62.5/125
62.5/125
50/125
50/125
50/125
160
200
400
500
2000
85 feet (26 m)
108 feet (33 m)
216 feet (66 m)
269 feet (82 m)
6,561 feet (2000 m)
10GBASE-LRM
(SFP-10G-LRM)
1310
MMF
62.5/125
50/125
50/125
500
400
500
722 feet (220 m)
328 feet (100 m)
722 feet (220 m)
SMF
G.6522
—
984 feet (300 m)
—
—
10GBASE-CX1
—
6.21 miles (10 km)
(SFP-H10GB-CU1M)
Twinax cable, 30-AWG
cable assembly
3 feet (1 m)
(SFP-H10GB-CU3M)
Twinax cable, 30-AWG
cable assembly
9 feet (3 m)
(SFP-H10GB-CU5M)
Twinax cable, 24-AWG
cable assembly
16 feet (5 m)
1. Modal bandwidth applies only to multimode fiber.
2. A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers.
3. A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF or 1000BASE-LX/LH SFP modules and a short link distance can
cause transceiver saturation and an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also
install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. The
mode-conditioning patch cord is required for link distances greater than 984 feet (300 m).
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
B-6
OL-19593-03
Appendix B
Connector and Cable Specifications
Cable and Adapter Specifications
4. 1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on
the fiber quality, the number of splices, and the connectors.
Four Twisted-Pair Cable Pinouts
Router or PC
1 TPO+
1 TP1+
2 TPO-
2 TP1-
3 TP1+
3 TPO+
6 TP1-
6 TPO-
4 TP2+
4 TP3+
5 TP2-
5 TP3-
7 TP3+
7 TP2+
8 TP3-
8 TP2-
Figure B-11
65272
Switch
Four Twisted-Pair Straight-Through Cable Schematic
Four Twisted-Pair Crossover Cable Schematic
Switch
Switch
1 TP0+
1 TP0+
2 TP0-
2 TP0-
3 TP1+
3 TP1+
6 TP1-
6 TP1-
4 TP2+
4 TP2+
5 TP2-
5 TP2-
7 TP3+
7 TP3+
8 TP3-
8 TP3-
65274
Figure B-10
Two Twisted-Pair Cable Pinouts
Two Twisted-Pair Straight-Through Cable Schematic
Switch
Router or PC
3 TD+
6 TD–
3 RD+
6 RD–
1 RD+
2 RD–
1 TD+
2 TD–
H5578
Figure B-12
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
OL-19593-03
B-7
Appendix B
Connector and Cable Specifications
Cable and Adapter Specifications
Two Twisted-Pair Crossover Cable Schematic
Switch
Switch
3 TD+
6 TD–
3 TD+
6 TD–
1 RD+
2 RD–
1 RD+
2 RD–
H5579
Figure B-13
Identifying a Crossover Cable
TYou can identify a crossover cable by comparing the two modular ends of the cable. Hold the cables
side-by-side with the tab at the back. The first (far left) colored wire (pin 1) at one end of the cable is
the third colored wire (pin 3) at the other end of the cable. The second colored wire (pin 2) at one end
of the cable is the sixth colored wire (pin 6) at the other end of the cable. See Figure B-14.
Figure B-14
Crossover Cable
1 2 3 4 5 6 7 8
127839
1 2 3 4 5 6 7 8
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
B-8
OL-19593-03
Appendix B
Connector and Cable Specifications
Cable and Adapter Specifications
Figure B-15
RJ-45 Crossover Cable Identification
Pin 1
Pin 2
Pin 3
62741
Pin 6
Console Port Adapter Pinouts
The console port uses an 8-pin RJ-45 connector, which is described in Table B-2 and Table B-3. If you
did not order a console cable, you need to provide an RJ-45-to-DB-9 adapter cable to connect the switch
console port to a PC console port. You need to provide an RF-45-to-DB-25 female DTE adapter if you
want to connect the switch console port to a terminal. You can order a kit with an adapter (part
number ACS-DSBUASYN=). For console port and adapter pinout information, see Table B-2 and
Table B-3.
Table B-2 lists the pinouts for the console port, the RF-45-to-DB-9 adapter cable, and the console device.
Table B-2
Console Port Signaling Using a DB-9 Adapter
Switch Console
Port (DTE)
RJ-45-to-DB-9
Terminal Adapter
Console
Device
Signal
DB-9 Pin
Signal
RTS
8
CTS
No connection
6
DSR
TxD
2
RxD
GND
5
GND
GND
5
GND
RxD
3
TxD
No connection
4
DTR
CTS
7
RTS
Table B-3 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE adapter, and the
console device.
Note
The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You can order a kit with the
adapter (part number ACS-DSBUASYN=) from Cisco.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
OL-19593-03
B-9
Appendix B
Connector and Cable Specifications
Cable and Adapter Specifications
Table B-3
Console Port Signaling Using a DB-25 Adapter
Switch Console
Port (DTE)
RJ-45-to-DB-25
Terminal Adapter
Console
Device
Signal
DB-25 Pin
Signal
RTS
5
CTS
No connection
6
DSR
TxD
3
RxD
GND
7
GND
GND
7
GND
RxD
2
TxD
No connection
20
DTR
CTS
4
RTS
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
B-10