5 Managing the Remote Cable MSO Links Solution Introduction

5 Managing the Remote Cable MSO Links Solution Introduction
CH A P T E R
5
Managing the Remote Cable MSO Links Solution
Revised: March 22, 2012, OL-24162-05
Introduction
This chapter describes the three monitoring mechanisms that you can use to monitor the traffic
optimization on remote links solution:
•
p3vlink command line utility (CLU)
•
SCE command line interface (CLI)
•
Reporter tool virtual links report template group
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-1
Chapter 5
Managing the Remote Cable MSO Links Solution
Virtual Link Names
Virtual Link Names
Each virtual link represents a single interface on the CMTS device and the virtual link name comprises
the CMTS device name and the interface name. The virtual links are named according to the following
naming convention:
<Device name>_<Interface name>
•
<Device name>—This portion of the name is set when configuring the CMTS in the vlink.cfg
configuration file.
•
<Interface name>—This portion of the name identifies the specific CMTS interface including the
direction and the interface index. This information is how the CMTS describes the interface
internally and it is retrieved from the CMTS device by using SNMP.
– The direction portion of the virtual link name indicates the virtual link direction. Values can be
upstream or downstream.
– The interface index indicates the specific interface on the CMTS of the virtual link.
This is a sample virtual link name for a CMTS device named Device-1:
Device-1_CMTS1/0-upstream 1
If a downstream virtual link contains two channels, then the virtual link names are displayed as:
<Device name>_<Interface name>-L<index of the primary channel>
or
<Device name>_<Interface name>-W
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-2
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
Monitoring Using the p3vlink Utility
The p3vlink utility provides the ability to show virtual link configurations and metrics related to the
virtual links. The command format is:
p3vlink OPERATION [OPTIONS]
Table 5-1 and Table 5-2 lists the p3vlink operations and options, respectively.
Table 5-1
p3vlink Operations
Operation
Description
Notes
--show
Displays the current general
configuration, CMTS device list, and
CMTS device information.
—
--show-device
—
Displays general configuration of the
specified CMTS device that is known to
the VLM. This includes non-Cisco CMTS
devices also.
To specify the CMTS device, use the -d
option.
To show all the links related to the CMTS
device, specify the --detail option.
--resync
Gets all the SCE virtual link
configurations and sends it to the SCE,
SCE-Sniffer DHCP LEG, and CM.
This is a nonblocking command. Query
operation and synchronization operation
are activated in the background.
To specify the SCE, use the -n
SCE_NAME option.
To specify a Collection Manager, use the
-n CM_NAME option. In this case, the
VLM gets all the SCE virtual links that are
related to the specified Collection
Manager and sends the data to the
Collection Manager.
This is a nonblocking command. Query
operation and synchronization operation
are activated in the background.
--resync-all
Gets all the SCE virtual link
configurations for each SCE and sends
them to the SCE, SCE-Sniffer DHCP
LEG, and Collection Manager.
--start-query
Starts the on demand query operation (and This is a nonblocking command. Query
operation and synchronization operation is
the CMTS device synchronization
operation) for one CMTS device or more activated in the background.
separated by “,”.
To specify the CMTS device to be queried,
use the -d <device name> option.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-3
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
Table 5-1
p3vlink Operations (continued)
Operation
Description
Notes
--show-vlinks
Shows the virtual links, virtual link
indexes, and bonding group information
related to the specified SCE.
—
to specify the SCE, use the -n <SCE
name> option.
(Optional) To specify the prefix of the
virtual links that you want this command
to show, use the --prefix=<vlink prefix>
option.
--show-vlink-data
Shows all the data related to the specified —
link.
To specify the vlink, use one of these
options:
--vlink-name=<name>
--vlink-id=<id>, --ne-name, and
--direction
--show-vlink-mappings
Shows the upstream and downstream vlink —
mappings that the virtual link manager
learnt from all configured CMTSs.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-4
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
Table 5-1
p3vlink Operations (continued)
Operation
Description
Notes
--show-subs
This command has four uses:
This command retrieves subscribers
whose giaddr attribute is one of the CMTS
devices giaddr attributes.
•
Shows all subscribers connected to a
specific CMTS device.
– To specify the CMTS device, use
The result can be filtered by using:
the -d <device name> option.
•
Prefix (first use only)
– (Optional) To specify the virtual
•
Vlink-id (first use only)
link ID, use the --vlink-id=<id>
option.
•
Direction
– (Optional) To specify the virtual
link direction, use the
--direction=<up|down> option.
– (Optional) To specify the prefix
of the virtual links that you want
this command to show, use the
--prefix=<vlink prefix> option.
•
Shows all subscribers connected to a
specific CMTS device interface, or
related to a specific CMTS device.
– To show all subscribers related to
the vlink, use
--vlink-name=<name>.
Because each vlink represents
one CMTS device interface, this
command enables you to see all
subscribers traveling from a
specific CMTS device interface.
•
Shows the bonding group if the cable
modems are DOCSIS 3.0 modems.
•
Shows the channelID, all subscribers
who are associated to this channelID,
and the direction of the channel, when
the DOCSIS 2.0 modem is assigned to
a single primary channel.
– To show the channel ID and the
directon of the channel, use
--channel-name=<channel
name>.
--remove-device
Removes a dynamic device from the VLM. After the device is removed, VLM deletes
all virtual links related to the device from
To specify the CMTS device, use the -d
the SCE. The subscribers of the affected
<device name> option.
device are logged in with default vlink
mappings.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-5
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
Table 5-1
p3vlink Operations (continued)
Operation
Description
Notes
--enable-logging –d
<device name>
Enables login on a specific device.
This command sets the log_all flag related
to the device to true.
--disable-logging –d
<device name>
--import-cmts-details
--file-name=
<Complete path of the file>
Table 5-2
To specify the CMTS device, use the -d
<device name> option.
Disables login on a specific device.
To specify the CMTS device, use the -d
<device name> option.
During load-config and SM restart
operations, the value of log_all is reset to
the value defined in the configuration file.
This command sets the log_all flag related
to the device to false.
During load-config and SM restart
operations, the value of log_all is reset to
the value defined in the configuration file.
Imports the CMTS credentials from a file. This command imports the device
credentials to VLM.
The device credentials are imported from
the file mentioned in the --file-name. After
importing, creates a CSV file in encrypted
format.
p3vlink Options
SM Option
Abbreviation
Description
--ne-name=NAME
-n NAME
Specifies the logical name of the SCE
platform or CM.
--device=DEVICE
-d DEVICE
Specifies the logical name of the CMTS
device.
--direction=up/down
—
Specifies the direction of the virtual link.
--prefix=vlink prefix
—
Specifies the virtual link prefix.
--vlink-name=vlink name
—
Specifies the virtual link name.
--vlink-id
—
Specifies the index of the virtual link.
--detail
—
(Optional) To display additional
information, use this option with the
--show-device operation.
--channel-name=NAME
—
Specifies the channel name. To list the
subscribers on a specific channel, use this
option with the --show-subs operation.
--file-name=
<Complete path of the file>
—
Specifies the complete path of the input file
to import the device credentials, Used with
--import-cmts-details operation.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-6
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
p3vlink Utility Examples
To show the CMTS device general configuration, CMTS device list, and CMTS device information:
p3vlink -–show
General data:
------------Start:
Yes
Monitor Every:
60 minutes
BW Up Factor
95
BW Down Factor
95
Next query operation:
Wed Nov 05 08:40:33 IST 2008
Next ip removal operation:
Wed Nov 12 10:40:11 IST 2008
Enable Device Learning:
true
Upstream Global Controllers:
None
Downstream Global Controllers: None
Device list
----------1) Name: device, Host Name: Paris, Type Static, Query state: Completed, Last
successful query: Wed Nov 05 08:39:35 IST 2008
Command terminated successfully
>
To show the general configuration of a specified CMTS device:
p3vlink --show-device -d CMTS1 --detail
Name:
Host Name:
IP:
Type:
SCE Related:
Upstream factor:
Downstream factor:
Last success Query:
Last Query Attempt:
Last Query Status:
Sync state with SCE:
Sync state with CM:
Giaddr List:
Upstream Global Controllers:
Downstream Global Controllers:
isLogAll:
Num of up interfaces:
Num of down interfaces:
CMTS1
Paris
192.0.2.10
Static
sce0
95
95
Thu Jun 19 17:54:48 IDT 2008
Thu Jun 19 17:54:48 IDT 2008
Completed
done
done
127.0.0.1
None
<GC Name>=<GC Value>,<GC Name>=<GC Value>…
true
6
2
VLink Information:
1) Name: CMTS1_Cmts0/0-upstream2, Vlink Id: 1, Direction UP, PIR 5000 kbps.
2) Name: CMTS1_Cmts0/0-downstream1, Vlink Id:1, Direction DOWN, PIR 10000 kbps
Channel Name: <vlink Name>-W, index <value>, PIR <value> kpbs, CIR <value> kpbs
Channel Name: <vlink Name>-L<channel index>, index <value>, PIR <value> kpbs, CIR
<value> kpbs
3) Name: CMTS1_Cmts0/0-upstream3, Vlink Id:2, Direction UP, PIR 10000 kbps.
4) Name: CMTS1_Cmts1/0-downstream1, Vlink Id:2, Direction DOWN, PIR 20000 kbps.
5) Name: CMTS1_Cmts0/0-upstream1, Vlink Id:3, Direction UP, PIR 10000 kbps.
6) Name: CMTS1_Cmts1/0-upstream2, Vlink Id:4, Direction UP, PIR 20000 kbps.
7) Name: CMTS1_Cmts1/0-upstream3, Vlink Id:5, Direction UP, PIR 20000 kbps.
8) Name: CMTS1_Cmts1/0-upstream1, Vlink Id:6, Direction UP, PIR 20000 kbps.
Command terminated successfully
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-7
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
>
The output of this command includes these four information elements:
•
Num of up interfaces—Summarizes the total number of upstream virtual links related to this CMTS
device. Unknown indicates that the VLM was not able to communicate with the CMTS device.
•
Num of down interfaces—Summarizes the total number of downstream virtual links related to this
CMTS device. Unknown indicates that the VLM was not able to communicate with the CMTS
device.
•
Sync state with SCE:
– Done—The SCE is fully synchronized with CMTS device information. When working in
cascade mode, both the active and standby SCEs are synchronized with CMTS device data.
– Not-done—The SCE (or one of the SCEs in cascade mode) is not synchronized with all CMTS
device data. Use the p3vlink --resync -n <sce which manages the device> command to perform
the synchronization operation.
– Sync-in-process—When VLM detects configuration changes, the change needs to be sent to the
SCE. During the update process, the VLM changes the sync state to Sync-in-process.
For successful updates, the SCE sync state is set to Done, else the value is set to Not-Done.
•
Sync state with Collection Manager:
– Done—The Collection Manager is fully synchronized with CMTS device information.
– Not-done—The CM is not synchronized with all CMTS device data. Use the
p3vlink --resync -n <sce which manages the device> command to perform the synchronization
operation.
– N/A—The SCE to which the CMTS device belongs, is not connected to any Collection
Manager.
– Sync-in-process – When VLM detects configuration changes, the change needs to be sent to the
Collection Manager. During the update process, the VLM changes the sync state to
Sync-in-process.
For successful updates, SCE sync state is set to Done, else the value is set to Not-Done.
•
Last Query Status:
– Not started—Query operation for the device was not started since the last SM boot.
– Completed—Last query was completed successfully.
– Failure—Last query failed to complete.
– Waiting for query—Query operation is in queue waiting for resources.
– In-query—Device is in the process of a query operation.
– Waiting for deletion—During the last query, if no giaddr was found, the system queues up the
device for deletion. This is applicable only to dynamic devices.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-8
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
To show all the virtual links for a specific network element (SCE):
p3vlink --show-vlinks -n sc0
device0_0_Cmts0/1-downstream1, vlink id=15, direction=DOWN
device0_0_Cmts0/1-upstream1, vlink id=8, direction=UP
device0_0_Cmts0/1-upstream2, vlink id=16, direction=DOWN
device0_1_Cmts1/1-downstream1, vlink id=11, direction=DOWN
device0_1_Cmts1/1-upstream1, vlink id=6, direction=UP
device0_1_Cmts1/1-upstream2, vlink id=12, direction=DOWN
device0_2_Cmts2/1-downstream1, vlink id=25, direction=DOWN
device0_2_Cmts2/1-upstream1, vlink id=13, direction=UP
device0_2_Cmts2/1-upstream2, vlink id=26, direction=DOWN
device0_3_Cmts3/1-downstream1, vlink id=13, direction=DOWN
device0_3_Cmts3/1-upstream1, vlink id=7, direction=UP
device0_3_Cmts3/1-upstream2, vlink id=14, direction=DOWN
device0_4_Cmts4/1-downstream1, vlink id=21, direction=DOWN
device0_4_Cmts4/1-upstream1, vlink id=11, direction=UP
device0_4_Cmts4/1-upstream2, vlink id=22, direction=DOWN
device0_5_Cmts5/1-downstream1, vlink id=1, direction=DOWN
device0_5_Cmts5/1-upstream1, vlink id=1, direction=UP
device0_5_Cmts5/1-upstream2, vlink id=2, direction=DOWN
device0_6_Cmts6/1-downstream1, vlink id=9, direction=DOWN
device0_6_Cmts6/1-upstream1, vlink id=5, direction=UP
device0_6_Cmts6/1-upstream2, vlink id=10, direction=DOWN
device1_0_Cmts7/1-downstream1, vlink id=3, direction=DOWN
device1_0_Cmts7/1-upstream1, vlink id=2, direction=UP
device1_0_Cmts7/1-upstream2, vlink id=4, direction=DOWN
device1_1_Cmts8/1-downstream1, vlink id=7, direction=DOWN
device1_1_Cmts8/1-upstream1, vlink id=4, direction=UP
device1_1_Cmts8/1-upstream2, vlink id=8, direction=DOWN
device1_2_Cmts9/1-downstream1, vlink id=27, direction=DOWN
device1_2_Cmts9/1-upstream1, vlink id=14, direction=UP
device1_2_Cmts9/1-upstream2, vlink id=28, direction=DOWN
device1_3_Cmts10/1-downstream1, vlink id=23, direction=DOWN
device1_3_Cmts10/1-upstream1, vlink id=12, direction=UP
device1_3_Cmts10/1-upstream2, vlink id=24, direction=DOWN
device1_4_Cmts11/1-downstream1, vlink id=19, direction=DOWN
device1_4_Cmts11/1-upstream1, vlink id=10, direction=UP
device1_4_Cmts11/1-upstream2, vlink id=20, direction=DOWN
device1_5_Cmts12/1-downstream1, vlink id=5, direction=DOWN
device1_5_Cmts12/1-upstream1, vlink id=3, direction=UP
device1_5_Cmts12/1-upstream2, vlink id=6, direction=DOWN
device1_6_Cmts13/1-downstream1, vlink id=17, direction=DOWN
device1_6_Cmts13/1-upstream1, vlink id=9, direction=UP
device1_6_Cmts13/1-upstream2, vlink id=18, direction=DOWN
Command terminated successfully
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-9
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
To show the vlink data of a specific link:
p3vlink --show-vlink-data --vlink-name=device_Cmts0/0-downstream1
VLink Name: device_Cmts0/0-downstream1
VLink Id:
1
Direction:
downstream
SCE Name:
sce0
Device Name: device
PIR:
200000000
Channels related to VLink
<name>-L, index <index>, PIR <value>, CIR <value>
<name>-W, index <index>, PIR <value>, CIR <value>
Related upstream virtual links —Lists all upstream interface related to the same MAC layer
as the selected downstream interface.
device_Cmts0/0-upstream0
device_Cmts0/0-upstream1
device_Cmts0/0-upstream2
device_Cmts0/0-upstream3
Note
If more than one vlink has the same name, this command displays the information for all the vlinks.
To show the upstream and downstream vlink mappings that the virtual link manager learnt from all
configured CMTSs:
p3vlink --show-vlink-mappings
IPDR Vlink Mapping Tables:
===========================
Upstream Table:
{10.52.206.2_1054_1=191, 10.52.206.2_1109_2=88,
10.52.206.2_1077_4=196, 10.52.206.2_1031_1=99,
10.52.206.2_1019_4=43, 10.52.206.2_1047_1=9,
10.52.206.2_1093_4=97, 10.52.206.2_1018_2=158,
10.52.206.2_1080_2=73, 10.52.206.2_1042_4=126}
Downstream Table:
{10.52.206.2_1110_185=9, 10.52.206.2_1106_169=3,
10.52.206.2_1093_153=7, 10.52.206.2_1095_161=5,
10.52.206.2_1092_149=1, 10.52.206.2_1108_177=6,
10.52.206.2_1107_173=2, 10.52.206.2_1094_157=8,
10.52.206.2_1109_181=4}
Command terminated successfully
To show the subscribers using virtual links:
•
Use the p3subsdb command to list all the subscribers:
p3subsdb --show-all
lynn_jones
Command terminated successfully
•
Use the p3subs command to show the virtual links of a particular subscriber:
p3subs --show -s lynn_jones
Name:
lynn_jones
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-10
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
Domain:
subscribers
Mappings:
IP: 1.1.1.13/32
Properties:
downVlinkId=7
Name=device1_1_Cmts8/1-downstream1
upVlinkId=4
Name=device1_1_Cmts8/1-upstream1
Custom Properties:
giaddr=1.1.1.1
Command terminated successfully
•
Use the p3vlink command to show the subscribers that are associated with a particular CMTS
device:
p3vlink --show-subs -d device1_1
Subscribers related to device: device1_1 vlink-id: 4, giaddr: 1.1.1.1, direction UP
lynn_jones
Subscribers related to device: device1_1 vlink-id: 7, giaddr: 1.1.1.1, direction DOWN
lynn_jones
Command terminated successfully
•
Use the p3vlink command to show the subscribers that are associated with a specific CMTS device:
p3vlink --show-subs -d Test0 --direction=Down --vlink-id=23
Subscribers related to device: Test0 vlink-id: 23, giaddr: 24.191.128.17, direction
DOWN010101010106010101010107
Command terminated successfully
•
Use the p3vlink command to show the subscribers that are associated with a specific Vlink:
p3vlink --show-subs --vlink-name test1_Cmts0/0-upstream2
Subscribers related to device: test1 vlink-id: 5, giaddr: 10.78.233.149, direction UP
010101010101
1 subscriber was found
Command terminated successfully
•
Use the p3vlink command to show the subscribers that are associated to a channel name:
p3subs --show -s sub1
Name:
sub1
Domain:
subscribers
Properties:
downVlinkId=11
Name=local_Modular-Cable1/0/0:1-L194
upVlinkId=11
Name=local_Cable7/0/2-upstream2
Custom Properties:
giaddr=10.78.233.233
Command terminated successfully
p3vlink --show-subs --channel-name=local_Cable7/0/2-upstream2
Subscribers related to device: local vlink-id: 11, giaddr: 10.78.233.233, direction UP
sub1
1 subscriber was found
Command terminated successfully
p3vlink --show-subs --channel-name=local_Modular-Cable1/0/0:1-L194
Subscribers related to device: local vlink-id: 11, giaddr: 10.78.233.233, direction
DOWN
sub1
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-11
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Using the p3vlink Utility
1 subscriber was found
Command terminated successfully
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-12
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the SCE CLI
Monitoring Virtual Links Using the SCE CLI
The SCE provides CLI commands to monitor the virtual links in the solution.
Table 5-3 lists the virtual links CLI commands.
Table 5-3
Virtual Links Commands
Commands
Description
Show Commands
show interface LineCard 0 virtual-links [all |
changed | different-from-template]
Displays:
show interface LineCard 0 virtual-links [status |
mapping]
•
All the defined virtual links, when you use the all option.
•
Virtual links whose configurations have changed from the
template, when you use the changed option.
•
Virtual links configurations that differ from the template, when
you use the different-from-template option.
Displays the status of virtual links and updates the log with virtual
links mapping.
To display the status of the virtual link, use the status option.
To update the log with virtual link mapping, use the mapping option.
This is a debug command.
show interface LineCard 0 virtual-links template Displays the virtual link template of both upstream and downstream
[direction [upstream | downstream]]
(Optional) To show only one direction, use the [direction [upstream
| downstream]] option.
Displays the default virtual link.
show interface LineCard 0 virtual-links default
direction [upstream | downstream] [counter |
agc-mapping]
(Optional) To specify the agc-mapping between virtual link and the
actual agc indexes, use the agc-mapping option.
(Optional) To specify the counter along with agc-mapping, enforce
rate and actual rate, use the counter option.
show interface LineCard 0 virtual-links [name
<name> | index <index>] direction [upstream |
downstream] [counter | agc-mapping]
Displays the virtual link by name or index.
To display the name or index of the virtual link, use the [name
<name> | index <index>] option.
(Optional) To specify the agc-mapping between virtual link and the
actual agc indexes, use the agc-mapping option.
(Optional) To specify the counter along with agc-mapping, enforce
rate and actual rate, use the counter option.
Add Commands
virtual-links index <index> direction [upstream |
downstream]
Adds a virtual link index.
(Optional) To specify a direction, use the [direction [upstream |
downstream]] option.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-13
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the SCE CLI
Table 5-3
Virtual Links Commands (continued)
Commands
Description
virtual-links index <index> name <name>
direction [upstream | downstream]
Adds a virtual link index and specifies a name.
To specify a name for the channel, use the name option.
(Optional) To specify a direction, use the [direction [upstream |
downstream]] option.
Remove Commands
no Virtual-links index <index> direction
[upstream | downstream]
Removes a virtual link associated with the specified index and
direction.
To specify the index, use the <index> option.
To specify the direction, use the direction option.
no Virtual-links all direction [upstream |
downstream]
Removes all the virtual links.
Set Commands
virtual-links index <index> direction [upstream |
downstream] gc <offset> set-PIR value <value>
Sets the virtual link index PIR values by gc-offset and direction.
Reset Commands
virtual-links index <index> direction [upstream |
downstream] gc <offset> reset-PIR
Resets the virtual link index PIR value by gc template offset and
direction to template values.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-14
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the SCE CLI
virtual-links Command Examples
These examples show the output from the CLI virtual links commands:
SCE2000#> show interface Linecard 0 virtual-links template
Virtual Link enabled
Global Virtual link Global Controller, upstream:
name = globalGC - pir: 8000000 - cir: 0 - al: 5
name = globalGC1 - pir: 8000000 - cir: 0 - al: 5
Virtual link Global Controller, upstream Template hierarchic:
Total bandwidth limit in Virtual-Link:
name = Virtual-Link Global Controller - pir: 8000000,8000000,8000000,8000000 - cir: 0
- al: 5
name = appGC - pir: 8000000,8000000,8000000,8000000 - cir: 0 - al: 5
Global Virtual link Global Controller, downstream:
name = globalGC1 - pir: 8000000 - cir: 0 - al: 5
Virtual link Global Controller, downstream Template hierarchic:
Total bandwidth limit in Virtual-Link:
name = Virtual-Link Global Controller - pir: 8000000,8000000,8000000,8000000 - cir: 0
- al: 5
name = appGC - pir: 8000000,8000000,8000000,8000000 - cir: 0 - al: 5
name = appGC1 - pir: 8000000,8000000,8000000,8000000 - cir: 0 - al: 5
name = appGC2 - pir: 8000000,8000000,8000000,8000000 - cir: 0 - al: 5
SCE2000#> show interface LineCard 0 virtual-links all
Virtual Link enabled
upstream Virtual-Link:
index=1, name=virtual link
index=2, name=virtual link
index=3, name=virtual link
downstream Virtual-Link:
index=1, name=virtual link
index=2, name=virtual link
index=3, name=virtual link
1
2
3
1
2
3
SCE2000#> show interface LineCard 0 virtual-links different-from-template
Virtual Link enabled
upstream Virtual-Link:
virtual index=1, name=virtual link 1
channel index=1, name=virtual channel 1, pir=99999, cir=99, al=9, agc index=3
application index=1, name=appGC-1, pir=8000000, cir=0, al=5, agc index=2
virtual index=2, name=virtual link 2
channel index=2, name=virtual channel 2, pir=99999, cir=99, al=9, agc index=7
application index=1, name=appGC-2, pir=8000000, cir=0, al=5, agc index=6
downstream Virtual-Link:
virtual index=3, name=virtual link 3
channel index=3, name=virtual channel 3, pir=99999, cir=99, al=9, agc index=15
application index=1, name=appGC-3, pir=8000000, cir=0, al=5, agc index=12
application index=2, name=appGC1-3, pir=8000000, cir=0, al=5, agc index=13
application index=3, name=appGC2-3, pir=8000000, cir=0, al=5, agc index=14
SCE8000#> show interface LineCard 0 virtual-links index 1 direction upstream agc-mapping
Virtual Link enabled
upstream Virtual-Link:
virtual index=1, name=virtual link 1
channel index=1, name=virtual channel 1, pir=99999, cir=99, al=9, agc index=3
application index=1, name=appGC-1, pir=8000000, cir=0, al=5, agc index=2
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-15
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the SCE CLI
SCE8000#> show interface LineCard 0 virtual-links index 1 direction upstream counter
Virtual Link enabled
upstream Virtual-Link:
virtual index=1, name=virtual link 1
channel index=1, name=virtual channel 1, pir=99999, cir=99, al=9, agc index=3,
enforce rate=99999, actual rate=0
application index=1, name=appGC-1, pir=8000000, cir=0, al=5, agc index=2, enforce
rate=8000000, actual rate=0
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-16
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the Reporter
Monitoring Virtual Links Using the Reporter
The Cisco SCA BB includes a Reporter tool that allows you to produce reports based on the traffic
analysis performed by the SCE platform. The information is sent from the SCE platform and is stored in
a database. The Reporter can query and retrieve information from the database and present the results in
a comprehensive range of reports.
The Reporter includes the Virtual Links Monitoring group of report templates that allow you to view
statistics of bandwidth or volume of traffic used by a virtual link. The reports are provided per service
usage counter for the total volume used by the virtual link. The volume consumption can be displayed
per service for the virtual link. The reports are provided per channel.
Each report can be filtered to focus on a virtual link ID, a virtual link name, a virtual link direction, or
a combination of the virtual link identifiers.
The Virtual Links Monitoring group includes these report templates:
•
VLink Bandwidth per Service—Shows the distribution of bandwidth among the different service
usage counters defined in the system for all subscribers.
•
VLink Aggregated Usage Volume per Service—Shows the total volume of traffic (upstream and
downstream) for each service usage counter.
•
VLink Bandwidth per Package—Shows the distribution of bandwidth among the different packages
defined in the system for selected vlinks.
•
VLink Hourly Usage Volume per Service—Shows the distribution of volume among the different
service usage counters defined in the system, grouped by hour.
•
VLink Daily Usage Volume per Service—Shows the distribution of volume among the different
service usage counters defined in the system, grouped by day.
•
Daily Peak BW for all VLinks—Shows the daily value of the maximum bandwidth (1-hour or 2-hour
average) for all virtual links.
•
Total Active Subscribers per VLink—Shows the number of active subscribers for a selected vlink.
•
VLink Bandwidth per Channel—Shows the distribution of bandwidth among the different channels
for selected vlinks.
•
Top Subscribers per VLink—Shows a list of the top subscriber volume consumption in a specific
hour or day for a selected Vlink.
•
Average Bandwidth per Subscribers per VLink—Shows the average bandwidth for a specific
subscriber for a selected vlink.
•
Accumulated Bandwidth Distribution per VLink—Shows the accumulated bandwidth distribution
for a selected vlink.
Creating a New Report Instance Using Cisco Insight
For details on creating a new report instance using Cisco Insight, see the Cisco Insight v2 User Guide.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-17
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the Reporter
Creating a New Report Instance Using SCA Reporter
To create a new report instance using the SCA Reporter, complete these steps:
Step 1
Go to the SCA BB console. From the Tools menu, choose Reporter.
The Reporter opens and the Templates tab appears.
Step 2
In Templates view, expand the Virtual Links Monitoring group.
Step 3
Right-click a report instance (for example, VLink Bandwidth per Service).
A popup menu appears.
Step 4
From the menu, choose New.
The New Report Wizard dialog box appears (Figure 5-1), allowing you to configure the new report.
Figure 5-1
Step 5
New Report Wizard Dialog Box
In the Report name field, enter the name of the report instance.
The default report name is VLink Bandwidth per Service #1. (If you create another report instance
from this report template, it is named VLink Bandwidth per Service #2, and so on. You can rename
report instances.)
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-18
OL-24162-05
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the Reporter
Step 6
To create a report that focuses on a particular CMTS device:
a.
In the Select VLink names row, click the right column and click the Browse button that appears.
b.
Click the Search button.
In the search box, enter the name of the CMTS device with an asterisk (*) before and after. For example,
*CMTS_1*.
All the virtual links that contain the string CMTS_1 appear.
c.
Select all the results and click OK.
The report that focuses on the specified CMTS device is created.
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
OL-24162-05
5-19
Chapter 5
Managing the Remote Cable MSO Links Solution
Monitoring Virtual Links Using the Reporter
Cisco Service Control for Managing Remote Cable MSO Links Solution Guide
5-20
OL-24162-05
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project