RadioRA 2 Repeaters
RadioRA 2 Repeaters extend the range of Radio
Frequency (RF) signals that are sent between
dimmers, switches, keypads, visor controls,
shades / draperies, and other devices. Repeaters
ensure error-free communication between
system components and prevent interference
from neighboring systems.
For systems that extend up to 30 ft (9 m),
one (1) Main Repeater is required to set up the
system. Up to four (4) Auxiliary Repeaters can
be added to extend the RF range for larger
system applications. Each Repeater has an
RF range of 30 ft (9 m), covering a total area of
approximately 2500 sq ft (232 m2).
RR-MAIN-REP-WH
Model Numbers
RR-MAIN-REP-WH*
Main Repeater
RR-AUX-REP-WH*
Auxiliary Repeater
*Only available in White (WH).
RR-AUX-REP-WH
www.lutron.com/radiora2
Lutron® | 1
product specifications
369-227d
09.17.10
RadioRA 2 Repeaters
Specifications
Model Numbers
RR-MAIN-REP-WH, RR-AUX-REP-WH
Power
Main / Auxiliary Repeater: 9 V
DC adapter:
60 Hz 6.5 W
Input: 120 V
300 mA
Output: 9 V
Typical Power
Consumption
Main Repeater: 3.1 W
Test conditions: one LED on, Ethernet cable plugged in, powered by
the 9 V adapter supplied.
Auxiliary Repeater: 0.6 W
Test conditions: one LED on, powered by the 9 V adapter supplied.
Regulatory Approvals
DC adapter: UL Listed for U.S. and Canada, NOM
Main / Auxiliary Repeater: FCC, IC, COFETEL
Environment
Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C),
0% to 90% humidity, non-condensing. Indoor use only.
300 mA
Low-Voltage Wire Type Two pair – one pair 18 AWG (1.0 mm2), one pair 22 AWG to 18 AWG
(0.5 mm2 to 1.0 mm2) twisted shielded – NEC® Class 2 / PELV cable.
Communications
Repeaters communicate with the system through RF. All devices
(except remote dimmers / switches) must be located within 30 ft (9 m)
of a Repeater. All Repeaters must be within 60 ft (18 m) of another
Repeater.
ESD protection
Tested to withstand electrostatic discharge without damage or memory
loss, in accordance with IEC 61000-4-2.
Surge Protection
Tested to withstand surge voltages without damage or loss of
operation, in accordance with IEEE C62.41-1991 Recommended
Practice on Surge Voltages in Low-Voltage AC Power Circuits.
Power Failure
Power failure memory: should power be interrupted, the Repeater will
return to its previous state when power is restored.
Mounting
Mount on a wall, ceiling, or level surface using the two #6 (M3) screws
provided.
Connections
Main Repeater: Ethernet, RS232, RS485 and USB (Lutron use only.)
Auxiliary Repeater: RS485
Warranty
1 Year Limited Warranty. http://www.lutron.com/resiinfo
Design Features
Test button - enters the system diagnostic
mode.
•
Add button - enters the system address mode.
•
Main Repeaters allow configuration and
integration to the system through Ethernet or
RS232 ports. See chart below.
•
Can be programmed from a PC.
•
RS485 port to connect to other Repeaters
through a wired link (daisy-chain).
•
2 | Lutron®
Ethernet
RS232
Configuration
X
Integration
X
X
24/7 Technical Support—800.523.9466
product specifications
09.17.10
369-227d
RadioRA 2 Repeaters
Dimensions
All dimensions are shown as
Front View
in
(mm)
Side View
6 ⁄4
(159)
1
USB
Main Repeater
Repeater Status
1
M
5 1⁄4
(133)
2
3
4
1/4
(6)
Communication
RF
Setup
Wired
Test
Add
2 3⁄4
(70)
Integrate
Power Repeater Link
COM
N/C
MUX
MUX
9V
1
2
3
4
Program / Integrate
Ethernet
RS232
Mounting Holes
3 3⁄4
(95)
1 1⁄16
(27)
4 1⁄4
(108)
Mounting
Vertical
Horizontal
Ceiling
Wall
#6 (M3) screw
recommended
(2 included)
Level Surface
www.lutron.com/radiora2
Lutron® | 3
product specifications
09.17.10
369-227d
RadioRA 2 Repeaters
Operation
USB
Main Repeater
Repeater Status
1
M
2
3
Repeater Status LEDs
Displays the status of the
Repeaters in the system while in
Test mode.
4
Communication
RF
Setup
Wired
Repeater Status
Add
Test
M
COM
MUX
MUX
9V
N/C
Power Repeater Link
1
2
3
4
Integrate
RS232
1
2
4
3
RF and wired LEDs
Displays the Tx / Rx activity on
the RF and wired links.
(Green=Tx; Orange=Rx)
Program / Integrate
Ethernet
Communication
RF
Setup
Test
Wired
Test
Add
Test and Add Buttons
Press and hold to enter the
system into Test mode or Add
mode.
Add
Test and Add LEDs
Flashes green to indicate that the
system is in Test mode or Add
mode.
Wired and RF Configuration
Main or Auxiliary Repeater
30 ft (9 m)
maximum
Wired Link (Daisy-chain)
1000 ft (305 m) maximum
NEC® Class 2/PELV cable
Two pair – one pair 18 AWG
(1.0 mm2), one pair 22 AWG to
18 AWG (0.5 mm2 to 1.0 mm2)
twisted shielded.
4 | Lutron®
30 ft (9 m)
maximum
30 ft (9 m)
maximum
RF Link
60 ft (18 m)
maximum
24/7 Technical Support—800.523.9466
product specifications
369-227d
09.17.10
RadioRA 2 Repeaters
Using Two Main Repeaters for Qualified Dealers/Installers
Qualified Level 2 (L2) dealers/installers can upgrade their software to provide support for a 200
device system by enabling the addition of a second main repeater subnet to the system.
Note: For questions on how to become a qualified L2 dealer/installer, please contact your
local Lutron® representative.
Connection Diagram for 2 Main Repeaters
Router/HUB/Switch2
PC
Ethernet1
Main repeater subnet #1
USB
Main repeater subnet #2
USB
Main Repeater
Main Repeater
Repeater Status
Repeater Status
1
M
Main
2
3
4
RF
Wired
Test
4
Integrate
Power Repeater Link
Program / Integrate
9V
Ethernet
RS232
COM
3
3
4
Wired
Test
MUX
2
RF
MUX
1
2
Communication
Setup
N/C
COM
MUX
MUX
9V
N/C
Power Repeater Link
Add
1
M
Main
Communication
Setup
1
2
3
4
Add
Integrate
RS232
Program / Integrate
Ethernet
Auxiliary Repeater
Repeater Status
1
M
Auxiliary
2
3
4
Communication
RF
Setup
Wired
Test
Add
Optional3
RS485
COM
MUX
MUX
9V
N/C
Power Repeater Link
1
2
3
4
Dimmer
Keypad
Auxiliary Repeater
Repeater Status
1
M
Auxiliary
2
3
4
Communication
RF
Setup
Wired
Test
Add
COM
MUX
Dimmer
MUX
9V
N/C
Power Repeater Link
1
2
3
4
Keypad
1
he two main repeaters must be connected by Ethernet during and after PC programming. The two
T
main repeaters do not communicate over the RF link.
2
The two main repeaters may be connected over Ethernet by one of the following:
a. Router
b. HUB or switch (only if static IP addresses are being used)
c. A
fter PC programming is complete, direct Ethernet connection without a router, HUB, or switch
(only if static IP addresses are being used)
3
Auxiliary repeaters and main repeaters on the same subnet can be optionally connected by RS485
wired links when the repeater RF range is exceeded.
a. The RS485 wired link cannot be connected between the two main repeater subnets
b. The RS485 wired link cannot be connected between two main repeaters.
c. R
S485 wired links can be used between any combination of main and auxiliary repeaters on the
same subnet.
www.lutron.com/radiora2
Lutron® | 5
product specifications
09.17.10
369-227d
RadioRA 2 Repeaters
Connections
Main Repeater
Bottom View
Top View
RF range:
To Repeater:
60 ft (18 m)
To other devices:
30 ft (9 m)
Mini-B USB Cable:
(Lutron use only)
Wired Link (Daisy Chain)
maximum 1000 ft (305 m)
GND
N / C
MUX
MUX
9V
Antenna
USB
RS232
CAT5 Cable:
maximum
328 ft
(100 m)
Ethernet
RS485
Power Jack (to adapter)
Model: T120-9DC-3-BL
NEC® Class 2 / IEC PELV
RS232 Cable:
maximum 50 ft
(15 m)
RS232 and Ethernet Pin Numbering
6
1
7
2
8
3
9
4
5
RS232
Pin #
Ethernet
Pin #
TxD
2
T+Ve
1
RxD
3
T-Ve
2
GND
5
R+Ve
3
R-Ve
6
Auxiliary Repeater
Top View
RF range:
To Repeater:
60 ft (18 m)
To other devices:
30 ft (9 m)
Antenna
87654321
Bottom View
Wired Link (Daisy Chain)
maximum 1000 ft (305 m)
GND
N / C
MUX
MUX
9V
RS485
Power Jack (to adapter)
Model: T120-9DC-3-BL
NEC Class 2 / IEC PELV
6 | Lutron®
24/7 Technical Support—800.523.9466