AMX Central Controllers - Insight Visual Systems

AMX Central Controllers - Insight Visual Systems
NetLinx NI–Series Controllers
For Small or Medium Rooms (7, 8 or 15 Control Ports).......... 230 – 238
For Large or Multiple Rooms (30 or 31 Control Ports)........... 239 – 247
NetLinx Cardframes
(customizable – just add control cards)............................. 248 – 251
NetLinx Communication Gateways
(utilizes KNX communication protocol)....................................... 253
NetLinx Cards and Shells
(select the right card for the application).................. 252, 254 – 262
Accessories....................................................................... 263 – 267
central controllers
I NTRO D U CT I ON c e n t r a l CONTROLLERS
RENOWNED RELIABILITY
Ensuring Every Command is Carried Out the First Time
AMX Central Controllers are synonymous with reliability, flexibility, and security. As the brains of every AMX control system,
the NetLinx family of products are designed to be a true IT standards-based, secure solution with remote monitoring and
management using a client-server architecture interfacing with the AMX Resource Management Suite software applications.
Furthermore, our command architecture supports net-centric management of devices – which simplifies equipment
management and maintenance and lowers total cost of ownership. In fact, they use the same VxWorks Real-Time Operating
System to control space shuttles and defense systems.
SYSTEM DIAGRAM
NetLinx Central Controllers can control large numbers of AMX
and third party devices via RS232, IP, IR and Contact Closure.
Lights
DLP Projector
AMX ALD-HWD-6ND
Dimmer
AMX ALD-H48
Lighting Interface
Surround Sound
Decoder / Amplifier
HD Satellite Receiver /
DVR
Screen Control
internet
Drape Control
LAN Switch
AMX NXT/D-1500VG-RGB
Touch Panel
AMX NetLinx NI-2100
Integrated Controller
(back panel)
DVD
MP3 Player /
Docking Station
Ethernet
Lighting
RS232
Infrared
Satellite Radio Receiver
Contact Closure
228
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
I NTRO D U CT I ON c e n t r a l CONTROLLERS
In keeping with our philosophy of providing flexible and open solutions AMX provides 2 ways to use NetLinx controllers.
We have a family of integrated controllers (the NI family) that come in prebuilt configurations. There are also a variety of
components that can be used to extend the capabilities of NI controllers or alternatively to create a custom NetLinx master
configuration with the exact specifications required for an installation.
Note : A M X has a fam ily of develo pme n t to o l s to he l p i n te gra to rs pro g ra m. The se so f t w a re a ppl i c a t i o ns ra nge f ro m A M Xho m e a nd A M Xm e e t i ngro o m f o r si m pl i f i e d, w i z a rd-l ik e p r o g r a m m in g
to N e tL i n x Studio for pr ogr am m ing th e mo st so p hi sti ca te d co n tro l syste m so l u t i o ns. A nd o ur dra g-a nd-dro p so f t w a re , V i sua l A rc hi t e c t , w hi c h o f f e rs pro gra m m i ng f l e x i bi l i t y, a s w e ll a s a n
e a s y to u s e inter fac e.
NetLinx NI-Series Controllers
Feature
CONTROLLERS COMPARISON CHART
NI-700
NI-900
NI-2100
NI-3100
NI-3101-SIG
Integrated NetLinx Master
Yes
Yes
Yes
Yes
Yes
NI-4100
Yes
AXLink Interface
Yes
Yes
Yes
Yes
Yes
Yes
ICSNet Interface
No
No
Optional
Optional
No
Yes
10/100 Ethernet
Yes
Yes
Yes
Yes
Yes
Yes
Digital Input/Output Ports
4
4
4
8
8
8
RS-232/RS-422/RS-485 Ports
2
1
3
7
6
7
IR/Serial Output Ports
1
3
4
8
8
8
Relay Ports
-
-
4
8
8
8
No
No
No
No
No
Yes
Expansion Card Slots
IR Port/Receiver
Yes
Yes
No
No
No
No
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
USB/Yes
Yes/Yes
Duet-Enabled (Device Discovery)
Yes
Yes
Yes
Yes
Yes
Yes
Built-In Web Server
Yes
Yes
Yes
Yes
Yes
Yes
304 MIPS
304 MIPS
404 MIPS
404 MIPS
404 MIPS
404 MIPS
64 MB
Programming via Serial Port/Ethernet
Processor Speed
On-Board Memory RAM
64 MB
64 MB
64 MB
64 MB
64 MB
Non-Volatile Memory 512 KB
512 KB
1 MB
1 MB
1 MB
1 MB
1 MB
FLASH Memory
32 MB
32 MB
512 MB CF Card
512 MB CF Card
256 MB
512 MB CF Card
Yes
Yes
Yes
Yes
Yes
Yes
Status LEDs
Design Tools
VisualArchitect™, NetLinx Studio™
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
229
c e n t r a l CONTROLLERS
2 | 0 | 1 | 4
S e ri a l
NI-700
n
R e l ay
n
IR
n
D ig it a l I/ O
NetLinx Integrated Controller
(FG2105-70)
EXPerience Kit(s) Available, see page 4-7
OVERVIEW
The NI-700 unit is geared to meet the specific control and
automation needs of a single room environment, in which both
price and functionality are the driving requirements. The NI-700
T RAI NI NG AVAI LABLE
Fo r i m po rt a nt i nst a l l a t i o n, c o nf i gura t i o n a nd pro g r a m m in g t e ch n iq u e s ,
A M X U ni v e rsi t y t ra i ni ng i s a v a i l a bl e . J ust v i si t ww w.a mx.c o m/ p r o d u c t s/
NI -7 0 0 . as p a nd cl i c k o n t he “Tra i ni ng” t a b.
is configured to control a limited number of video players,
projectors, lights, thermostats, and other electronic equipment.
COMMON APPLICATIONs
AWARD W I NNER
The NI -7 0 0 w a s a w a rde d t he “ Hi gh I m pac t P r odu c t o f t h e Ye a r ”
f ro m C E Pro .
Ideal for single-room environments with a limited number of
devices such as classrooms, conference rooms, hotel rooms and
other applications.
FEATURES
• Ultra-fast 304 MIPS processor
• 2 configurable RS-232 / RS-422 / RS-485 Ports
• 1 IR / Serial Output Port
• 1 IR Receiver Port
• 4 Digital I/O Ports
• 1 Ethernet 10/100 Port
• 1 AxLink Connector
• 64 MB RAM
• 32 MB Flash Memory
• Duet-enabled (Device Discovery)
ONLINE www.amx.com/products/NI-700.asp
230
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
N I - 7 0 0 c e n t r a l CONTROLLERS
I R LED (r ed )
A CLOSER LOOK
I /O LEDs (y el l o w )
Link/Active-Status-Output-Input
(g r een /r ed /y el l o w )
I D P u s h b u tto n
Pr ogr am Por t
Configuration
I R RX LED (r ed )
DI P s w i tch
Serial RS-232/422/485 TX/RX
LEDs (r ed /y el l o w )
R S-2 3 2 /4 2 2 /4 8 5 (Por ts 1 & 2)
Eth er n et
PWR
I R/S er i al
(Po r t 3 )
IR RX
(Por t 5)
I/ O (Por t 4 )
Ax Li n k p o r t
Ax Li n k LED (g r een )
ClassroomManager,
Part of AMX’s Resource Management Suite
AMX EL Series
In-Ceiling 6.5” Speakers
AMX NetLinx NI-700
Integrated Controller
(back view of controller)
Network
AMX UPC20+
Universal Power/
Motor Controller
Amplifier
DVD/VCR Combo
Screen
AMX Novara
16-Button KeyPad
Ethernet
RS-232
Composite
Projector
Laptop
RGBHV
Variable Audio Output
Audio
Room Computer
IO Logic Output
IR
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
231
N I - 7 0 0 c e n t r a l CONTROLLERS
SPECIFICATIONS
rear panel connectors
DIMENSIONS (HWD)
• RS-232/422/485 (Ports 1 & 2)
• IR RX (Port 5)
• Digital I/O (Port 4)
• IR/Serial (Port 3)
• AxLink LED
• AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector provides data and
power to external control devices
• Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show
communication activity, connection status, speeds, and mode information:
- SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
- L/A (link/activity) - Green LED lights On when the Ethernet cables are
connected and terminated correctly, and blinks when receiving Ethernet
data packets.
• Power Port
• 1 9/16” x 5 9/16” x 5 1/8” (4.01 cm x 14.10 cm x 13.00 cm)
• RU: 1
WEIGHT
1.30 lbs (590 g)
POWER
• 280 mA @ 12 VDC
• Power requirements are usage dependant
enclosure
Metal with black matte finish
Memory
• 64 MB SDRAM
• 1 MB of Non-volatile SRAM
• 32 MB FLASH
ONBOARD MASTER
304 MIPS
ENVIRONMENTAL
• Operating Temperature: 0º C (32º F) to 50º C (122º F)
• Operating Humidity: 20% to 85% RH
• Heat Dissipation (Typical): 11.5 BTU/hr
certifications
FCC Part 15 Class B, CE, and IEC 60950
front panel components
232
• Program Port
• Configuration DIP Switch: Sets the communication parameters for the
Program port
• IR RX LED: Red LED lights when IR data is being received via the rear
IR RX port
• IR LED: Red LED lights during the transmission of IR or Serial data via the rear
IR port
• I/O LEDs: Four yellow LEDs light when the rear I/O channels 1 - 4 are active.
LED indicator for each I/O port reflects the state of that particular port
• Serial LEDs
• LINK/ACT: Green LED lights when the Ethernet cable is connected and an
active link is established. This LED also blinks when receiving Ethernet
data packets
• Status: Green LED lights when the Controller is programmed and
communicating properly
• Output: Red LED lights when the Controller transmits data, sets channels
sends data strings, etc.
• Input: Yellow LED lights when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
• ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device
included accessories
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
PSN6.5
PSN4.4 AC-RK
AC-SMB
AC-PMB
CC-232 CC-NIRC 6.5 Amp Power Supply (FG423-41)
4.4 Amp Power Supply (FG423-45)
Accessory Rack Kit
(FG515)
Surface Mounting Bracket
(FG525)
Pole Mounting Bracket
(FG531)
RS232/422 Cables
IR Cables (FG10-000-11)
• 2-pin 3.5 mm mini-Phoenix female PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix female connector (41-5047)
• 6-pin 3.5 mm mini-Phoenix female I/O connector (41-5063)
• CC-NIRC IR Emitter
ONLINE
PAGE #
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/AC-RK.asp
www.amx.com/products/AC-SMB.asp
www.amx.com/products/AC-PMB.asp
www.amx.com/products/CC-232.asp
www.amx.com/products/CC-NIRC.asp
291
290
264
263
263
295
294
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
1 | 0 | 3 | 4
S e ri a l
n
R e l ay
n
IR
n
D ig it a l I/ O
NI-900
NetLinx Integrated Controller
(FG2105-90)
EXPerience Kit(s) Available, see page 4-7
OVERVIEW
The NI-900 unit is designed to control and automate a variety of
devices in single rooms or multiple small rooms and is capable
of supporting devices with a variety of communication formats. It
T RAI NI NG AVAI LABLE
Fo r i m po rt a nt i nst a l l a t i o n, c o nf i gura t i o n a nd pro g r a m m in g t e ch n iq u e s ,
A M X U ni v e rsi t y t ra i ni ng i s a v a i l a bl e . J ust v i si t ww w.a mx.c o m/ p r o d u c t s/
NI -9 0 0 . as p a nd cl i c k o n t he “Tra i ni ng” t a b.
is configured to control a limited number of lights, thermostats,
video displays and other equipment.
COMMON APPLICATION
Perfect for single rooms or two or more small rooms with a limited
number of devices such as home theaters, MDUs, hotel rooms
and other environments.
FEATURES
• 1 Configurable RS-232 / RS-422 / RS-485 Serial port
• 3 IR / Serial ports
• 1 IR Receiver Port
• 4 Digital I/O ports
• 2 Communication Networks: AxLink and Ethernet (TCP/IP)
• 304 MIPS processor speed
• 64 MB RAM
• 32 MB Memory
• 512 KB Non-Volatile Memory
• AMX Device Discovery enabled
ONLINE www.amx.com/products/NI-900.asp
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
233
N I - 9 0 0 c e n t r a l CONTROLLERS
A CLOSER LOOK
IR L ED (r e d)
I/ O LED s (y e llow )
RS -2 3 2 /4 2 2 /4 8 5 (Po r t 1 )
IR RX L ED (r e d)
Pro gra m Po r t
Configuration
D IP s w itc h
I R RX
(Po r t 6 )
Eth er n et
I R/S er i al
(Po r ts 2 -4 )
Ax Li n k p o r t
PWR
I /O (Po r t 5 )
I D P u s h b u tto n
Ax Li n k LED (g r een )
Serial RS-232/422/485
TX/ RX LED (r e d/ y ellow )
Link/Active-Status- O u t p u t - I n p u t
(gr e en/ r ed/ y ellow )
AMX EL Series
In-Ceiling 6.5” Speakers
AMX NXD-CV5
5" Modero Wall/Flush
Mount Touch Panel
AMX Metreau
6-Button Keypad
with Navigation
AMX NetLinx NI-900
Integrated Controller
(back view of controller)
AMX UPC20+
Universal Power/
Motor Controller
AV Receiver
Display
Blinds
Ethernet
DVD
RS-232
AxLink
Audio Video
Set Top Box
Audio
IO Logic Output
IR
234
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
N I - 9 0 0 c e n t r a l CONTROLLERS
SPECIFICATIONS
DIMENSIONS (HWD)
rear panel connectors
• 1 9/16” x 5 9/16” x 5 1/8” (4.01 cm x 14.10 cm x 13 cm)
• RU: 1
ONBOARD MASTER
• RS-232/422/485 (Port 1)
• IR RX (Port 6)
• Digital I/O (Port 5)
• IR/Serial (Ports 2 - 4)
• AxLink LED
• AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector provides data and
power to external control devices
• Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show
communication activity, connection status, speeds, and mode information:
- SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
- L/A (link/activity) - Green LED lights On when the Ethernet cables are
connected and terminated correctly, and blinks when receiving Ethernet
data packets.
• Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector
304 MIPS
ENVIRONMENTAL
WEIGHT
1.30 lbs (590 g)
POWER
• 300 mA @ 12 VDC
• Power requirements are usage dependent
enclosure
Metal with black matte finish
Memory
• 64 MB SDRAM
• 1 MB of Non-volatile SRAM
• 32 MB FLASH
• Operating Temperature: 0º C (32º F) to 50º C (122º F)
• Operating Humidity: 20% to 85% RH
• Heat Dissipation (Typical): 12.3 BTU/hr
certifications
FCC Part 15 Class B, CE, and IEC 60950
front panel components
• Program Port
• Configuration DIP Switch: Sets the communication parameters for the
Program port
• IR RX LED: Red LED lights when IR data is being received via the rear
IR RX port
• IR LEDs: Three red LEDs light during the transmission of IR or Serial data via
the rear IR port
• I/O LEDs: Four yellow LEDs light when the rear I/O channels 1-4 are active.
LED indicator for each I/O port reflects the state of that particular port
• Serial LEDs
• LINK/ACT: Green LED lights when the Ethernet cable is connected and an
active link is established. This LED also blinks when receiving Ethernet
data packets
• Status: Green LED lights when the Controller is programmed and
communicating properly
• Output: Red LED lights when the Controller transmits data, sets channels,
sends data strings, etc.
• Input: Yellow LED lights when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
• ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device
included accessories
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
PSN6.5
PSN4.4 AC-RK
AC-SMB
AC-PMB
CC-232 CC-NIRC 6.5 Amp Power Supply (FG423-41)
4.4 Amp Power Supply (FG423-45)
Accessory Rack Kit
(FG515)
Surface Mounting Bracket
(FG525)
Pole Mounting Bracket
(FG531)
RS232/422 Cables
IR Cables (FG10-000-11)
• 2-pin 3.5 mm mini-Phoenix female PWR connector (41-5025)
• 6-pin 3.5 mm mini-Phoenix female I/O connector (41-5063)
• Three CC-NIRC IR Emitters
• Two 4-pin 3.5 mm mini-Phoenix female connectors (41-5047)
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
ONLINE
PAGE #
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/AC-RK.asp
www.amx.com/products/AC-SMB.asp
www.amx.com/products/AC-PMB.asp
www.amx.com/products/CC-232.asp
www.amx.com/products/CC-NIRC.asp
291
290
264
263
263
295
294
235
c e n t r a l CONTROLLERS
3 | 4 | 4 | 4
S e ri a l
n
R e l ay
n
IR
n
D ig it a l I/ O
NI-2100
NetLinx Integrated Controller
NI-2100 Controller
(FG2105-04)
NI-2100 Controller with ICSNet
(FG2105-14)
EXPerience Kit(s) Available, see page 4-7
OVERVIEW
The NI-2100 is ideal for control and automation of
medium-sized rooms and multi-room applications. The NI-2100
has 64MB of onboard RAM and is Dynamic-Discovery enabled
T RAI NI NG AVAI LABLE
Fo r i m po rt a nt i nst a l l a t i o n, c o nf i gura t i o n a nd pro g r a m m in g t e ch n iq u e s ,
A M X U ni v e rsi t y t ra i ni ng i s a v a i l a bl e . J ust v i si t ww w.a mx.c o m/ p r o d u c t s/
NI -2 1 0 0 . as p a nd cl i c k o n t he “Tra i ni ng” t a b.
to simplify programming by standardizing device and function
definitions, default touch panel button assignments, and control
and feedback methods.
COMMON APPLICATION
The NI-2100 is a good fit for medium-sized rooms or multi-room
applications in home theaters, whole homes, hotel rooms and
other environments.
FEATURES
• 3 Configurable RS-232 / RS-422 / RS-485 Serial port
• 4 Relays
• 4 IR / Serial ports
• 4 Digital I/O ports
• 2 Communication Networks: AxLink and Ethernet (TCP/IP)
• 404 MIPS processor speed
• 64 MB RAM
• 512 MB CompactFlash (upgradeable to 1 G)
• 1 MB Non-Volatile Memory
• AMX Device Discovery enabled
ONLINE www.amx.com/products/NI-2100.asp
236
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
N I - 2 1 0 0 c e n t r a l CONTROLLERS
A CLOSER LOOK
I /O LEDs (y el l o w )
RS-232/ 422/ 485 TX/ RX LEDs (r ed /y el l o w )
L ink/ Ac tiv e-Status -Output-Input
RS-232/ 422/ 485 (Por ts 1-3)
Rel ay LEDs (r ed )
I R/S er i al LEDs (r ed )
I C S Net co v er p l ate
Eth er n et
PWR
Re lay s (Por t 4)
I/ O (Por t 9)
P r o g r am p o r t DI P s w i tch
I D P u s h b u tto n
IR/ Se r ial (Por ts 5 -8 )
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
Ax Li n k p o r t
Ax Li n k LED
(g r een )
237
N I - 2 1 0 0 c e n t r a l CONTROLLERS
SPECIFICATIONS
DIMENSIONS (HWD)
rear panel connectors
• 3 1/2” x 17” x 3 1/2” (8.8 cm x 43.2 cm x 8.8 cm)
• RU: 2
• RS-232/422/485 (Ports 1 - 3)
• ICSNet: Two RJ-45 connectors for ICSNet interface (provided by ICSNet
daughter card)
• ICSHub Out: RJ-45 connector provides data to a Hub connected to the
Controller (provided by ICSNet daughter card)
• Relay (Port 4)
• Digital I/O (Port 9)
• IR/Serial (Ports 5 - 8)
• Program Port
• Configuration DIP Switch: Sets the communication parameters for the
Program port
• ID Pushbutton
• Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show
communication activity, connection status, speeds, and mode information:
- SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
- L/A (link/activity) - Green LED lights On when the Ethernet cables are
connected and terminated correctly, and blinks when receiving Ethernet
data packets.
• AxLink LED: Green LED indicates the state of the AxLink port.
• AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector that provides data
and power to external control devices
• Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector.
WEIGHT
4.50 lbs (2.04 kg)
POWER
700 mA @ 12 VDC
enclosure
Metal with black matte finish
memory
• 64 MB SDRAM
• 1 MB of Non-volatile SRAM
COMPACT FLASH
512 MB Card or more (upgradeable)
ONBOARD MASTER
404 MIPS
certifications
FCC Part 15 Class B, CE, and IEC 60950
front panel components
• LINK/ACT: Green LED blinks when the Ethernet cables are connected and
terminated correctly. Also blinks when receiving Ethernet data packets
• Status: Green LED blinks to indicate that the system is programmed and
communicating properly
• Output: Red LED blinks when the Controller transmits data, sets channels and
sends data strings, etc.
• Input: Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
• RS-232/422/485 LEDs
• Relay LEDs
• IR/Serial LEDs
• I/O LEDs
• Rack-mount brackets: Provides an installation option for the Integrated
Controller to be mounted into an equipment rack, when used with the
Installation Kit (KA2105-01)
238
ENVIRONMENTAL
• Heat Dissipation (Typical): 28.7 BTU/hr
included acessories
• 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix (female) AxLink connector (41-5047)
• 6-pin 3.5 mm mini-Phoenix female I/O connector (41-5063)
• 8-pin 3.5 mm mini-Phoenix female Relay connector (41-5083)
• Two CC-NIRC IR Emitters
• Two removable rack ears (62-2105-07)
RECOMMENDED ACCESSORIES
DESCRIPTION
PSN6.5
PSN4.4 NXA-ICSNET
NXA-CF2NI
CC-232 CC-NIRC 6.5 Amp Power Supply (FG423-41)
4.4 Amp Power Supply (FG423-45)
NetLinx ICSNet Communication Network Card (FG2105-10)
CompactFlash Upgrade
(FG21116-xx)
RS232/422 Cables
IR Cables (FG10-000-11)
PART #
ONLINE
PAGE #
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/NXA-ICSNET.asp
www.amx.com/products/NXA-CF2NI.asp
www.amx.com/products/CC-232.asp
www.amx.com/products/CC-NIRC.asp
291
290
267
266
295
294
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
7 | 8 | 8 | 8
S e ri a l
n
R e l ay
n
IR
n
D ig it a l I/ O
NI-3100
NetLinx Integrated Controller
NI-3100 Controller
(FG2105-05)
NI-3100 Controller with ICSNet (FG2105-15)
EXPerience Kit(s) Available, see page 4-7
OVERVIEW
With the ability to integrate a large number of devices, the
NI-3100 controls a wide variety of components including
audio/video conferencing, projectors, VCR and DVD players,
T RAI NI NG AVAI LABLE
Fo r i m po rt a nt i nst a l l a t i o n, c o nf i gura t i o n a nd pro g r a m m in g t e ch n iq u e s ,
A M X U ni v e rsi t y t ra i ni ng i s a v a i l a bl e . J ust v i si t ww w.a mx.c o m/ p r o d u c t s/
NI -3 1 0 0 . as p a nd cl i c k o n t he “Tra i ni ng” t a b.
projectors, lights, thermostats and other electronic equipment
found in larger areas. With these technology-driven environments,
the NI-3100 also provides solutions for future expansion and
enables the addition of more devices and control capabilities.
Offers higher performance with an ultra-fast processor, 64MB of
onboard RAM and is AMX Device Discovery enabled.
COMMON APPLICATION
The NI-3100 unit is ideally suited to the requirements of larger
areas or multiple rooms with advanced control and
automation features.
FEATURES
• 7 Configurable RS-232 / RS-422 / RS-485 Serial ports
• 8 Relays
• 8 IR / Serial ports
• 8 Digital I/O ports
• 2 Communication Networks: AxLink and Ethernet (TCP/IP)
• 404 MIPS processor speed
• 64 MB RAM
• 512 MB CompactFlash (upgradeable to 1 G)
• 1 MB Non-Volatile Memory
• AMX Device Discovery enabled
ONLINE www.amx.com/products/NI-3100.asp
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
239
N I - 3 1 0 0 c e n t r a l CONTROLLERS
A CLOSER LOOK
I /O LEDs (y el l o w )
RS-232/ 422/ 485 TX/ RX L EDs (r ed /y el l o w )
Link/ Ac tiv e-Status -Output-Input
Rel ay LEDs (r ed )
I R/S er i al LEDs (r ed )
I C S Net co v er p l ate
RS-232/ 422/ 485 (Por ts 1-7)
R e lay s (Por t 8)
I D P u s h b u tto n
DI P s w i tch
I/ O (Por t 17)
IR/ Se r ial (Por ts 9-16)
240
P r o g r am p o r t
PWR
Eth er n et
Ax Li n k p o r t
Ax Li n k LED
(g r een )
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
N I - 3 1 0 0 c e n t r a l CONTROLLERS
SPECIFICATIONS
DIMENSIONS (HWD)
rear panel connectors
• 3 1/2” x 17” x 3 1/2” (8.8 cm x 43.2 cm x 8.8 cm)
• RU: 2
• RS-232/422/485 (Ports 1 - 7)
• ICSNet: Two RJ-45 connectors for ICSNet interface (provided by ICSNet
daughter card)
• ICSHub Out: RJ-45 connector provides data to a Hub connected to the
Controller (provided by ICSNet daughter card)
• Relay (Port 8)
• Digital I/O (Port 17)
• IR/Serial (Ports 9 - 16)
• Program Port
• Configuration DIP Switch: Sets the communication parameters for the
Program port
• ID Pushbutton
• Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show
communication activity, connection status, speeds, and mode information:
- SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
- L/A (link/activity) - Green LED lights On when the Ethernet cables are
connected and terminated correctly, and blinks when receiving Ethernet
data packets.
• AxLink LED
• AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector that provides data
and power to external control devices
• Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector
WEIGHT
4.55 lbs (2.06 kg)
POWER
900 mA @ 12 VDC
enclosure
Metal with black matte finish
memory
• 64 MB SDRAM
• 1 MB of Non-volatile SRAM
COMPACT FLASH
512 MB Card or more (upgradeable)
ONBOARD MASTER
404 MIPS
certifications
FCC Part 15 Class B, CE, and IEC 60950
front panel components
• LINK/ACT
• Status: Green LED blinks to indicate that the system is programmed and
communicating properly
• Output: Red LED blinks when the Controller transmits data, sets channels and sends data strings, etc.
• Input: Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
• RS-232/422/485 LEDs
• Relay LEDs
• IR/Serial LEDs
• I/O LEDs
• Rack-mount brackets: Provides an installation option for the Integrated
Controller to be mounted into an equipment rack, when used with the
Installation Kit (KA2105-01)
ENVIRONMENTAL
Heat Dissipation (Typical): 36.9 BTU/hr
included accessories
• 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix (female) AxLink connector (41-5047)
• 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107)
• Two 8-pin 3.5 mm mini-Phoenix female Relay connectors (41-5083)
• Two CC-NIRC IR Emitters
• Two removable rack ears (62-2105-07)
RECOMMENDED ACCESSORIES
DESCRIPTION
PSN6.5
PSN4.4 NXA-ICSNET
NXA-CF2NI
CC-232 CC-NIRC 6.5 Amp Power Supply (FG423-41)
4.4 Amp Power Supply (FG423-45)
NetLinx ICSNet Communication Network Card (FG2105-10)
CompactFlash Upgrade
(FG21116-xx)
RS232/422 Cables
IR Cables (FG10-000-11)
PART #
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
ONLINE
PAGE #
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/NXA-ICSNET.asp
www.amx.com/products/NXA-CF2NI.asp
www.amx.com/products/CC-232.asp
www.amx.com/products/CC-NIRC.asp
291
290
267
266
295
294
241
c e n t r a l CONTROLLERS
6 | 8 | 8 | 8
S e ri a l
NI-3101-SIG
n
R e l ay
n
IR
n
D ig it a l I/ O
Signature Series NetLinx Integrated Controller
®
(FG2105-08)
EXPerience Kit(s) Available, see page 4-7
OVERVIEW
FEATURES
With its gloss-black face, blue power bar and blue and white
• 6 Configurable RS-232 / RS-422 / RS-485 Serial Ports
status LEDs, the NI-3101-SIG can be placed on open racks, open
• 8 Relays
shelves, tables, home theaters or behind the scenes in a rack.
• 8 IR / Serial ports
Measuring just 1 rack unit (RU:1) high, the NI-3101-SIG frees up
• 8 Digital I/O ports
space for other components while the extended rack depth (10”)
• 2 Communication Networks: AxLink and 10/100 Ethernet
simplifies rear connections.
(TCP/IP)
• Integrated USB programming port
With extremely fast 32-bit processing and 64MB of onboard RAM,
• 404 MIPS processor speed
the NI-3101-SIG is capable of processing thousands of control
• 64 MB RAM
and automation commands per second. Whether your control
• 256 MB Flash
requirements are simple or sophisticated, the NI-3101-SIG is fast,
• 1 MB Non-Volatile Memory
accurate and immediate. In addition, it features a convenient USB
• AMX Device Discovery enabled
programming port to simplify configuration.
ONLINE www.amx.com/products/NI-3101-SIG.asp
COMMON APPLICATION
The NI-3101-SIG is ideal for controlling devices in large areas and
T RAI NI NG AVAI LABLE
Fo r i m po rt a nt i nst a l l a t i o n, c o nf i gura t i o n a nd pro g r a m m in g t e ch n iq u e s ,
A M X U ni v e rsi t y t ra i ni ng i s a v a i l a bl e . J ust v i si t ww w.a mx.c o m/ p r o d u c t s/
NI -3 1 0 1 -S I G. as p a nd cl i c k o n t he “Tra i ni ng” t a b.
multiple rooms. Its sleek styling and professional showroom finish
allow it to be displayed prominently in home theater
environments or work equally well behind the scenes in a rack.
WAT C H T HE V I DEO
See the NI-3101-SIG in action by watching the video profile online
a t : www. am x . c om /as s ets /v i deos /NI -3 1 0 1 -S I G. m p 4
242
RECOMMENDED ACCESSORIES
DESCRIPTION
PSN6.5
PSN4.4 CC-232 CC-NIRC CC-NET CC-USB-NI
6.5 Amp Power Supply (FG423-41)
4.4 Amp Power Supply (FG423-45)
RS232/422 Cables
IR Cables (FG10-000-11)
Cat5 Ethernet Cable (FG10-051-10)
USB Programming Cable (FG10-2105)
PART #
ONLINE
PAGE #
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/CC-232.asp
www.amx.com/products/CC-NIRC.asp
www.amx.com/products/CC-NET.asp
www.amx.com/products/CC-USB-NI.asp
291
290
295
294
293
294
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
N I - 3 1 0 1 - S I G c e n t r a l CONTROLLERS
A C LO SE R LOOK
Po wer
Link/ Ac tiv e-Status -I/ O
Rel ay LEDs
RS-232/ 422/ 485 TX/ RX LEDs
R S-2 3 2 /4 2 2/ 485 (Por ts 1-6)
I R/S er i al LEDs
C o n fi g u r ati o n
S w i tch es
I /O (Po r t 1 7 )
Re lay s (Por t 8 )
AMX ALD-HWD-6ND
Dimmer
AMX ALD-H48
Lighting Interface
I /O LEDs
I D S w i tch
P r o g r am m i n g
Po r t
I R/S er i al (Po r ts 9 -1 6 )
Ax Li n k
LED
Eth er n et
1 0 /1 0 0 Po r t
Lights
Po we r
12 VDC
A xL in k
Po rt
DLP Projector
Surround Sound
Decoder / Amplifier
HD Satellite Receiver /
DVR
Screen Control
internet
Drape Control
LAN Switch
AMX Mio Modero
Prestige S Keypad
AMX NXT/D-1500VG-RGB
Touch Panel
AMX NetLinx NI-3101-SIG
Integrated Controller
DVD
(back view of controller)
Ethernet
MP3 Player /
Docking Station
AxLink
Lighting
RS232
Infrared
Satellite Radio Receiver
Contact Closure
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
243
NI-3101-SIG c
C e n t r a l CONTROLLERS
SPECIFICATIONS
DIMENSIONS (HWD)
I/O LEDs
• 2” x 17” x 10” (4.4 cm x 43.2 cm x 25.4 cm)
• RU: 1
Eight white LEDs light when the I/O channels 1-8 are active on Port 17
WEIGHT
REAR PANEL COMPONENTS
6.95 lbs (2.68 kg)
POWER CONNECTOR
POWER
2-pin (male) green captive-wire connector for 12 VDC power supply
900 mA @ 12 VDC
ETHERNET 10/100 PORT
Metal with black matte finish and translucent polycarbonate faceplate
RJ-45 Ethernet 10/100 connector. Automatically negotiates connection speed
and whether to use half or full duplex mode
ONBOARD MASTER
AxLink CONNECTOR
Processing Power: 32-bit microprocessor, 404 MIPS, Real-time operating system
Memory: Volatile – 64 MB, Non-Volatile – 1 MB, Flash – 256 MB
Networking:
• AxLink – 4-wire network (20.8 kbps) connects up to 255 Axcess devices,
operates up to 3,000 feet of wiring and supplies 12 VDC power
• Ethernet – Direct 10/100 BaseT Ethernet networking
Ethernet Protocols used by NI-3101-SIG
• ICSP – peer to peer protocol used for both master-to-master and
master-to-device communications
• ICMP – To connect over a network, ping a NI-3101-SIG
• Telnet – NetLinx telnet server provides a mechanism to configure and diagnose
a NetLinx system
• HTTP – NI-3101-SIG has a built-in web server that complies with the HTTP 1.0
specification and supports all of the required features of HTTP v1.1
• FTP – NI-3101-SIG has a built-in FTP server that conforms to RFC959
• integration! Solutions – uses port 10500 for XML based communication protocol
Black 4-pin (male) captive-wire connector that provides data and power to
external control devices (6 A max power rating)
CONTROL PORTS
• 8-channel single-pole single throw relay ports
• Each relay is independently controlled
• Supports up to 8 independent external relay devices
• Each relay can switch up to 24 VDC or 28 VAC @ 1 A
• Two 8-pin mini-Phoenix connectors (3.5 mm) provide relay termination
ENCLOSURE
• Six Serial data control ports (RS-232/422/485), with XON/XOFF and CTS/RTS,
300-115,200 baud
• Eight IR/Serial ports for control of up to 1.142 MHz carrier frequency
• Eight I/O channels for contact closure, 0-5 VDC voltage sensing, or interactive
power sensing for IR ports
• Eight Relays - single-pole single-throw relay ports, independently controlled
FRONT PANEL COMPONENTS:
LED INDICATORS
USB connector that supports USB communications to a PC for system
programming and diagnostics
CONFIGURATION DIP SWitch
4-position DIP switch
ID BUTTON
Pushbutton sets device address ID (in conjunction with NetLinx Studio v1.2 build
200 or higher software program)
RS-232/422/485: (PORTS 1-6)
Six RS-232/422/485 control ports using DB-9 (male) connectors with XON/
XOFF (transmit on/transmit off), CTS/ RTS (clear to send/ready to send), and
300-115,200 baud
RELAYS (PORT 8)
DIGITAL I/O (PORT 17)
• 8-channel binary I/O port for contact closure
• Each input is capable of 0-5 VDC voltage sensing. Input format is software
selectable
• One 10-pin mini-Phoenix connector (3.5 mm) provide I/O port termination
• LNK/ACT: Blue LED lights when the Ethernet cables are connected and
terminated correctly and blinks when receiving Ethernet data packets
• Status: Blue LED blinks to indicate that the system is programmed and
communicating properly
• Output: Blue LED blinks when the Master transmits data, sets channels on
and off, sends data strings, etc.
• Input: White LED blinks when the Master receives data from button pushes,
strings, commands, channel levels, etc.
IR/SERIAL (PORTS 9-16)
RS-232/422/485 LEDs
• Removable rack ears allow for tabletop, under-counter, and front/rear
rack mounting
• Removable feet give a finished look and provide spacing between stacked
components
• Two 8-pin mini-Phoenix female connectors (41-5083)
• One 10-pin mini-Phoenix female connector (41-5107)
• Two CC-NIRC IR Emitters (FG10-000-11)
• One 4-pin 3.5 mm mini-Phoenix AxLink connector (41-5047)
• One 2-pin mini-Phoenix PWR connector (41-5025)
• One Relay Terminal Common Strip (41-2105-01)
• Four Rack mount screws (80-0186)
• Four washers (80-0342)
• Six sets of blue and white LEDs light to indicate Ports 1-6 are transmitting
or receiving RS-232, 422, or 485 data
• TX LEDs (blue) blink when transmitting data
• RX LEDs (white) blink when receiving data
RELAY LEDs
Eight blue LEDs light to indicate relay channels 1-8 are active (closed) on Port 8
IR/SERIAL LEDs
Eight blue LEDs light to indicate the IR/Serial ports 9-16 are transmitting
control data
244
PROGRAM PORT
• Eight IR/Serial control ports support high-frequency carriers up to 1.142 MHz
• Each output is capable of two electrical formats: IR or Serial
• Eight IR/Serial data signals can be generated simultaneously
• Two 8-pin mini-Phoenix connectors (3.5 mm) provide IR/ Serial port termination
ENVIRONMENTAL
Heat Dissipation (Typical): 36.9 BTU/hr
INCLUDED ACCESSORIES
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
7 | 8 | 8 | 8
S e ri a l
n
Relay
n
IR
n
D ig it a l I/ O
NI-4100
NetLinx Integrated Controller
(FG2105-06)
OVERVIEW
The NI-4100 provides versatility with the ability to integrate the
largest number of devices in the NI Series of Master Controllers,
including projectors, lighting, VCR and DVD players, thermostats
T RAI NI NG AVAI LABLE
Fo r i m po rt a nt i nst a l l a t i o n, c o nf i gura t i o n a nd pro g r a m m in g t e ch n iq u e s ,
A M X U ni v e rsi t y t ra i ni ng i s a v a i l a bl e . J ust v i si t ww w.a mx.c o m/ p r o d u c t s/
NI -4 1 0 0 . as p a nd cl i c k o n t he “Tra i ni ng” t a b.
and other electronic equipment. In these technology-driven
environments, this solution allows for the future addition of more
devices and control capabilities. With a perfect mix of compatible
formats, the NI-4100 offers flexibility and customization for
businesses experiencing rapid growth and for homes that
demand seamless integration of technology and design. The
NI-4100 provides higher performance with a faster processor,
64MB of onboard RAM and Duet-compatibility.
COMMON APPLICATION
The NI-4100 is geared to meet the high-end control and
automation requirements of the most sophisticated and complex
commercial and residential installations.
FEATURES
• 7 Configurable RS-232 / RS-422 / RS-485 Serial ports
• 8 Relays
• 8 IR / Serial ports
• 8 Digital I/O ports
• 3 Communication Networks: AxLink, ICSNet and
Ethernet (TCP/IP)
• 4 NetLinx Control Card Expansion slots that support all NXC
control cards
• 404 MIPS processor speed
• 64 MB RAM
• 512 MB CompactFlash (upgradeable to 1G)
• 1 MB Non-Volatile Memory
• AMX Device Discovery enabled
ONLINE www.amx.com/products/NI-4100.asp
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
245
N I - 4 1 0 0 c e n t r a l CONTROLLERS
A CLOSER LOOK
I /O LEDs (y el l o w )
RS-232/ 422/ 485 T X /RX LEDs (r ed /y el l o w )
Rel ay
LEDs (r ed )
L ink/ Ac tiv e-Status -Output-I n p u t
IR/Serial
LEDs (r ed )
Net Li nx C a rd Slots (1-4)
I C S Hu b Ou t
I C S Net (2 )
RS-232/ 422/ 485 (Por ts 1-7)
Ax Li n k LED
(g r een )
Ax Li n k p o r t
I/O ( Por t 17)
PWR
R el a ys (Por t 8)
C a rdFra me DIP s w itc h
Slot 1-4 conne ctor s
IR/ Ser i al (Po r ts 9 -1 6 )
Projection Screen
DI P s w i tch
Eth er n et
P r o g r am p o r t
Drapes
Venue Lighting
Radia Eclipse
6 Dimmer Module
Video Projector
AMX NetLinx NI-4100
Integrated Controller
AMX ABS
AxLink Bus Strip
(back view of controller)
AMX AXB-VOL3
3-Channel Volume Controller
Amplifier
Dual
MIDI Transceiver
SMPTE
Transceiver
AMX NXA-ENET24
Managed Ethernet
Switch
Speakers
Mixer
Ethernet
SMPTE Time
Code Generator
Internet
Serial
AxLink
Relay
VGA
PC
AMX NXA-WAP250G
802.11b/g
Wireless Access Point
Lighting
MIDI
SMPTE
Audio
246
AMX NXT/D-1700VG-RGB
Touch Panel
AMX MVP-8400i
Touch Panel with Intercom
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
N I - 4 1 0 0 c e n t r a l CONTROLLERS
SPECIFICATIONS
DIMENSIONS (HWD)
rear panel connectors
• 5 3/16” x 17” x 9 5/16” (13.2 cm x 43.2 cm x 23.7 cm)
• RU: 3
• RS-232/422/485 (Ports 1 - 7)
• ICSNet: Two RJ-45 connectors for ICSNet interface (included)
• ICSHub Out: RJ-45 connector provides data to a Hub connected to the
Controller (included)
• Relay (Port 8)
• Digital I/O (Port 17)
• IR/Serial (Ports 9 - 16)
• Program Port
• Configuration DIP Switch: Sets the communication parameters for the
Program port
• ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device
• Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show
communication activity, connection status, speeds, and mode information:
- SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
- L/A (link/activity) - Green LED lights On when the Ethernet cables are
connected and terminated correctly, and blinks when receiving Ethernet
data packets.
• AxLink LED: Green LED indicates the state of the AxLink port
• AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector that provides data
and power to external control devices
• Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector
• CardFrame Number DIP Switch
WEIGHT
9.15 lbs (4.15 kg)
POWER
900 mA @ 12 VDC
enclosure
Metal with black matte finish
memory
• 64 MB SDRAM
• 1 MB of Non-volatile SRAM
COMPACT FLASH
512 MB Card or more (upgradeable)
ONBOARD MASTER
404 MIPS
certifications
FCC Part 15 Class B, CE, and IEC 60950
front panel components
• LINK/ACT: Green LED blinks when the Ethernet cables are connected and
terminated correctly. Also blinks when receiving Ethernet data packets
• Status: Green LED blinks to indicate that the system is programmed and
communicating properly
• Output: Red LED blinks when the Controller transmits data, sets channels, sends data strings, etc.
• Input: Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
• RS-232/422/485 LEDs
• Relay LEDs
• IR/Serial LED
• I/O LEDs
• NetLinx Control Card Slot 1 - 4
• Rack-mount brackets: Provides an installation option for the Integrated
Controller to be mounted into an equipment rack, when used with the
Installation Kit (KA2105-01)
ENVIRONMENTAL
Heat Dissipation (Typical): 36.9 BTU/hr
included accessories
• 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix (female) AxLink connector (41-5047)
• 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107)
• Two 8-pin 3.5 mm mini-Phoenix (female) Relay connectors (41-5083)
• Two CC-NIRC IR Emitters
• Two removable rack ears (62-2105-07)
RECOMMENDED ACCESSORIES
DESCRIPTION
PSN6.5
PSN4.4 NXA-CF2NI
6.5 Amp Power Supply (FG423-41)
4.4 Amp Power Supply (FG423-45)
CompactFlash Upgrade for NI Series Controllers (FG21116-xx)
PART #
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
ONLINE
PAGE #
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/NXA-CF2NI.asp
291
290
266
247
c e n t r a l CONTROLLERS
6 | 12 | 8 | 8
S e ri a l
n
R e l ay
n
IR
n
D ig it a l I/ O
NXI
NetLinx Controller
(No Master)
(FG2101)
OVERVIEW
The NetLinx Controller provides incredibly powerful control and
A CLOSER LOOK
networking capabilities and instantly commands projectors, window treatments, security, lighting and even PCs with a full array of
RS-232/422/485 ports, IR/Serial ports, Inputs/Output channels and
I C S P LED (g r een )
Rel ay s (p o r t 7 )
RS -2 3 2 /4 2 2 /4 8 5 ( p o rt s 1 - 6 )
relays. Measuring only 1 rack unit (1U) the NXI NetLinx Integrated
Controller frees up space for other components.
COMMON APPLICATION
The NetLinx Controller’s sleek modular design and compact size
I R/S er i al (p o r ts 8 -1 5 )
I /O (p o r t 1 6 )
I D P u s h b u tto n
M as ter /H u b C a rd S lo t
make it perfect for open shelves and tables within home theaters
and residences or behind the scenes in a rack used for commercial applications.
FEATURES
• 6 Configurable RS-232 / RS-422 / RS-485 Serial ports
• 12 Relays
• 8 IR / Serial ports
• 8 Digital I/O ports
ONLINE www.amx.com/products/NXI.asp
248
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
N x i c e n t r a l CONTROLLERS
SPECIFICATIONS
DIMENSIONS (HWD)
rear panel connectors
• 1 3/4” x 17” x 8 13/16” (4.4 cm x 43.2 cm x 22.4 cm)
• RU: 1
• ID Pushbutton: Sets the D:P:S assignment for the NXI
• ICSP LED: Green LED Blinks in unison with the Master card’s NetLinx LED
indicating the ICSP bus is synchronized. This LED flashes rapidly when the NXI
is in ID Mode (see Using the ID Button for details)
• RS-232/422/485 (Ports 1-6): Six RS-232/422/485 control ports with XON/
XOFF (transmit on/transmit off), and CTS/RTS (clear to send/ready to send),
300-230,400 baud:
- Channel range = 1-255
- Channels 1-254 provide feedback only.
- Channel 255 (CTS Push channel) reflects the state of the CTS
- Input if a ‘CTSPSH’ command was sent to the port.
• Relays (Port 7): Twelve-channel relay port. Channel range = 1-12
- You can connect up to 12 independent external relay devices to the Relay
connectors on the NXI (Port 7).
- Connectors labeled A are for common and B are for Output.
- Each relay is isolated and normally open.
• IR/Serial (Ports 8-15): Eight IR/Serial control ports that support
high-frequency carriers up to 1.14 MHz:
- Channel range = 1-32,000
- Channels 1-253 (output): IR commands.
- Channel 254 (feedback): PowerFail (used with ‘PON’ and ‘POF’ commands).
- Channel 255 (feedback): Power status (when IOLink is set).
• I/O (Port 16): 8-channel I/O port for contact closure, 0-5 VDC voltage
sensing, or interactive power sensing for IR ports. Channel range = 1-8
WEIGHT (without processor)
4.0 lbs (1.8 kg)
POWER
1.09 mA @ 12 VDC
enclosure
Metal with black matte finish
memory
• 64K of IR memory
- 32K IR memory for IR ports 8-11
- 32K IR memory for IR ports 12-15
port assignments
• Ports 1-6 = RS-232/422/485 Ports
• Port 7 = 12 Relays
• Ports 8-15 = IR/IR Serial Ports
• Port 16 = 8 I/O Channels
certifications
FCC Part 15 Class B, CE, and IEC 60950
front panel components
• Master/Hub Card slot: Accepts an NXC-ME260 or Hub Card
• RS-232/422/485 TX/RX LEDs: Six sets of red and yellow LEDs light to indicate
ports 1-6 are transmitting or receiving RS-232, 422, or 485 data:
- TX LEDs (red) blink when transmitting data
- RX LEDs (yellow) blink when receiving data
• Relay LEDs: Twelve red LEDs light to indicate relay channels 1-12 are
active (closed)
• IR/Serial LEDs: Eight red LEDs light to indicate IR/Serial channels 1-8 are
transmitting control data
• I/O LEDs: Eight yellow LEDs light when I/O channels 1-8 are active
RECOMMENDED ACCESSORIES
DESCRIPTION
ENVIRONMENTAL
Heat Dissipation (Typical): 44.7 BTU/hr
included accessories
• 4 CC-NIRC emitters
• Metal tab strips for commoning adjacent relays
• Rack-mount brackets adapt for rack, wall, or shelf mounting
• NetLinx faceplate
PART #
NXC-ME260/64
NetLinx Master Ethernet Card (FG2010-64)
NXC-NH
ICSNet Hub Card (FG2060)
NXC-HE
ICSHub Expander Card
(FG2062)
NXC-COM2
Dual COM Port Control Card
(FG2022)
NXC-I/O10
Input/Output Control Card
(FG2021)
NXC-IRS4
4-Port IR/S Control Card (FG2023)
NXC-REL10
Relay Control Card (FG2020)
NXC-VAI4
Voltage Output/Analog Input Control Card (FG2025)
NXC-VOL4
Volume Control Card (FG2024)
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
ONLINE
PAGE #
www.amx.com/products/NXC-ME260-64.asp
www.amx.com/products/NXC-NH.asp
www.amx.com/products/NXC-HE.asp
www.amx.com/products/NXC-COM2.asp
www.amx.com/products/NXC-I-O10.asp
www.amx.com/products/NXC-IRS4.asp
www.amx.com/products/NXC-REL10.asp
www.amx.com/products/NXC-VAI4.asp
www.amx.com/products/NXC-VOL4.asp
252
254
255
258
262
257
261
259
260
249
c e n t r a l CONTROLLERS
NXF
NetLinx CardFrame
(CardFrame Only)
(FG2001)
OVERVIEW
SPECIFICATIONS
The NetLinx CardFrame is easy-to-use and easy-to-understand.
DIMENSIONS (HWD)
Customize and control any connected device by simply inserting
• 3 1/2” x 17” x 9 5/8” (8.9 cm x 43.2 cm x 24.4 cm)
• RU: 2
up to twelve NetLinx Control Cards directly into the front-access
slots of the CardFrame. For maximum speed, add an optional
Master Card with Ethernet which crunches code at great speeds,
stores innovative AMX control solutions, and is capable of
extending control over multiple networks.
WEIGHT
9.1 lbs (4.1 kg)
POWER
+12 VDC
enclosure
Metal with black matte finish
ONLINE www.amx.com/products/NXF.asp
front panel components
• Master/Hub Card Slot: Houses the Master or Hub Card
• Control Card Slots: 12 card slots for the NetLinx Control Cards that control
devices connected to the CardFrame
A CLOSER LOOK
Contr ol Car d c on n ecto r s
(20-pin male) 1-1 2
M a st er/H ub C a rd s lot
rear panel
• Control Card connectors (1-12) 20-pin black (male) connectors that connect
the optional Control Cards and external equipment to the CardFrame
• POWER: 2-pin green (male) connector for connecting a 12 VDC power supply
• CardFrame can be powered via the Master Card (default) or by an external
power supply connected to the CardFrame’s PWR connector
• 256 CardFrames for total support of up to 3072 NetLinx Control Cards
PWR (pow e r ) conne ctor (2-pin mal e)
C o n t r ol Card slots (1-12)
Car dF r ame N umbe r (de v ic e ID ) D I P s w i tch
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
NXC-ME260/64
NetLinx Master Ethernet Card (FG2010-64)
NXC-NH
ICSNet Hub Card (FG2060)
NXC-HE
ICSHub Expander Card
(FG2062)
NXC-COM2
Dual COM Port Control Card
(FG2022)
NXC-I/O10
Input/Output Control Card
(FG2021)
NXC-IRS4
4-Port IR/S Control Card (FG2023)
NXC-REL10
Relay Control Card (FG2020)
NXC-VAI4
Voltage Output/Analog Input Control Card (FG2025)
NXC-VOL4
Volume Control Card (FG2024)
250
ONLINE
PAGE #
www.amx.com/products/NXC-ME260-64.asp
www.amx.com/products/NXC-NH.asp
www.amx.com/products/NXC-HE.asp
www.amx.com/products/NXC-COM2.asp
www.amx.com/products/NXC-I-O10.asp
www.amx.com/products/NXC-IRS4.asp
www.amx.com/products/NXC-REL10.asp
www.amx.com/products/NXC-VAI4.asp
www.amx.com/products/NXC-VOL4.asp
252
254
255
258
262
257
261
259
260
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NXF-MINI
NetLinx Mini-CardFrame
(CardFrame Only)
(FG2104)
OVERVIEW
SPECIFICATIONS
The NetLinx Mini-CardFrame features front access to four
DIMENSIONS (HWD)
expansion slots that accept any combination of compatible
• 1 3/4” x 17” x 9 9/16” (4.5 cm x 43.2 cm x 24.3 cm) (width does not include
mounting ears)
• RU: 1
NetLinx Controller Cards. In addition to being compatible with
the ME260/64 Master Card, NI-2100, NI-3100 and the NI-4100
NetLinx Controllers, the Mini-CardFrame extends the control
WEIGHT
6.2 lbs (2.8 kg)
capabilities of the AMX NetLinx Control System to a remote area
POWER
or location up to 1,000 feet away through the power of the ICSNet
25 mA @ 12 VDC
data/power bus.
enclosure
Metal with black matte finish
common application
front panel components
The NXF-MINI NetLinx Mini-CardFrame is ideal for expansion
• NetLinx Control Card Slots 1- 4: Accept up to 4 compatible NetLinx Cards: such
as the NXC-COM2, NXC-I/O10, etc.
• Rack-mount brackets: Provides an installation option for the NXF-MINI to be
mounted into an equipment rack
for distributed systems needing additional IR, Relay, and Volume
Control capabilities.
ONLINE www.amx.com/products/NXF-MINI.asp
QU IC K T IP
For additional ex pand a bi l i ty n e e ds, mu l ti pl e Ne tL i nx
Mini- Car dFr am es c an b e co n ne cte d u si n g I CSNe t Hubs.
rear panel connectors
• CardFrame Number DIP Switch: Sets the starting address for the Control Cards
in the CardFrame. The 8-position DIP switch address range is 1-3064. (Factory
default CardFrame DIP switch value = 0). The Control Card address range
is 1-3064
• NetLinx Control Card Connectors (1-4): Four 20-pin (male) connectors that
bridge the gap between the Control Cards in the CardFrame and
external equipment
• ICSNet Connector: Single RJ-45 connector for ICSNet interface
• Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector
included accessories
• Removable rack ear set (62-2104-03). Allows for tabletop, under-counter, and
front/rear rack mounting
• Three faceplate screws (80-0181)
• One 2-pin mini-Phoenix PWR connector (41-5025)
• Installation Kit (KA2104)
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
PSN6.5
NXC-COM2
NXC-I/O10
NXC-IRS4
NXC-REL10
NXC-VAI4
NXC-VOL4
6.5 Amp Power Supply Dual COM Port Control Card
Input/Output Control Card
4-Port IR/S Control Card Relay Control Card Voltage Output/Analog Input Control Card Volume Control Card (FG423-41)
(FG2022)
(FG2021)
(FG2023)
(FG2020)
(FG2025)
(FG2024)
www.amx.com/products/PSN6.5.asp
www.amx.com/products/NXC-COM2.asp
www.amx.com/products/NXC-I-O10.asp
www.amx.com/products/NXC-IRS4.asp
www.amx.com/products/NXC-REL10.asp
www.amx.com/products/NXC-VAI4.asp
www.amx.com/products/NXC-VOL4.asp
291
258
262
257
261
259
260
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
251
c e n t r a l CONTROLLERS
NXC-ME260/64
enclosure
Metal with black matte finish
NetLinx Master
Ethernet Card
front panel components
is propelled by the high-speed 257 MIPS ColdFire processor.
• Program port: DB9 (male) connector that supports RS-232 communications
to your PC for system programming and diagnostics. Set the port’s
communication speed with the Baud Rate DIP switch. Program ports are
located on the front and rear panels of the Master Card for easy access.
Because these ports share the same circuitry, they should never be used at the
same time; doing so will result in communication and/or programming errors
• Status LED: Green LED blinks to indicate system and communication status
• Output LED: Red LED blinks when the Master Card transmits data, sets
channels on and off, sends data strings, etc.
• Input LED: Yellow LED blinks when the Master Card receives data from button
pushes, strings, commands, channel levels, etc.
• Program Port DIP Switch 8-position DIP switch on the front of the card for
setting the baud rate for the Program port
The standard 32MB CompactFlash memory is expandable to
rear panel
(FG2010-64)
OVERVIEW
The NetLinx NXC-ME260/64 Card supplies optimum control
system performance. With the ability to respond 50 times
faster than conventional control masters, the NXC-ME260/64
1G and beyond and Ethernet networking is built onboard. The
NXC-ME260/64 also features enhanced Username and Password
authentication, HTTPS and SSL certificate interaction, ICSP
communication and encryption, and use of a pre-installed AMX
SSL certificate.
features
• 1 AxLink Bus
• 1 Ethernet (TCP/IP) Port
• 2 ICSNet Ports
• 2 ICSHub Ports
• 257 MIPS processor speed
• 64 MB RAM
• 512 MB CompactFlash (upgradeable to 1 G)
• 1 MB Non-Volatile Memory
ONLINE www.amx.com/products/NXC-ME260-64.asp
SPECIFICATIONS
DIMENSIONS (HWD)
• 1 5/16” x 5” x 8 13/16” (3.4 cm x 12.7 cm x 22.4 cm)
• RU: 1
ENVIRONMENTAL
Heat Dissipation (Typical): 30.7 BTU/hr
WEIGHT
included accessories)
8.8 oz (250 g)
• 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix (female) AxLink connector (41-5047)
• 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107)
• Installation Kit (KA2105-01)
• Two 8-pin 3.5 mm mini-Phoenix (female) Relay connectors (41-5083)
• Two CC-NIRC IR Emitters
• Two removable rack ears (62-2105-07)
POWER
750 mA @ 12 VDC
memory
• Compact Flash: 512 MB standard (upgradeable)
• Volatile: 64 MB
• Non-volatile: 1 MB
252
• P WR connector: 2-pin (male) green captive-wire connector for 12 VDC
power supply
• EXPANSION OUT: port RJ-11 connector connects to an AXB-SPE Slave
Port Expander
• Ethernet 10/100 port: The (RJ-45) Ethernet Port default setting automatically
negotiates the connection speed (10 Mbps or 100 Mbps) and whether to use
half duplex or full duplex mode
• Ethernet 10/100 LEDs: Display communication activity, connections, speeds,
and mode information.
• AxLink connector Black 4-pin (male) captive-wire connector that provides
data and power to external control devices. Power rating = 6 A max; actual load
depends on connected power supply
• AxLink Status LED: Green LED blinks to show AxLink and expansion port
data activity
• PROGRAM port: 5-pin (male) gray connector for system programming and
diagnostics. There is a Program port located on the front and rear of the
Master Cards for easy access. Because these ports share the same circuitry,
you should never use both ports at the same time. Doing so will result in
communication and/or programming errors
• ICSNet connectors: Two RJ-45 connectors that provide power (500 mA) and
data to external ICSNet devices
- ICSNet LEDs - Indicate activity on that port.
• ICSHub In/Out connectors: Two RJ-45 connectors that provide data to other
Hubs connected to the Master Card
- ICSHub IN/OUT LEDs - Indicate activity on that port
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
NXS-MHS
NXA-CFM
PSN6.5
PSN4.4 PSN2.8
Master/Hub Module Shell
CompactFlash Upgrade for NXC-ME260/64 6.5 Amp Power Supply 4.4 Amp Power Supply 13.5 VDC, 2.8 A Power Supply
(FG2009)
(FG2116-xx)
(FG423-41)
(FG423-45)
(FG423-17)
www.amx.com/products/NXS-MHS.asp
www.amx.com/products/NXA-CFM.asp
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/PSN2.8.asp
256
266
291
290
289
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NXB-KNX
SPECIFICATIONS
KNX Communications Gateway
(FG2031-01)
DIMENSIONS (HWD)
• 1 5/8” x 5 1/2” x 4 1/8” (4.21 cm x 14.1 cm x 10.4 cm)
• RU: 1
WEIGHT
1.45 lbs (0.65 kg)
FRONT PANEL COMPONENTS
communicate with homes and buildings that utilize the KNX
• Status LED (green): Blinks once a second to indicate that the unit has powered
up. Any state other than blinking once a second indicates the unit is either not
powered, or has not completed boot up
• KNX LED (green): Solid on indicates power is on and the unit is connected to KNX bus
• Output LED (red): Lights to indicate traffic from the NXB-KNX to the KNX bus
• Input LED (yellow): Lights to indicate traffic from the KNX bus to the NXB-KNX
communication protocol. This standard eliminates the problems
REAR PANEL CONNECTORS
of isolated devices/sub-systems and ensures that all components
• KNX 2-pin captive-wire connector
• Ethernet Port - 10/100 Ethernet with PoE. LEDs show communication activity,
connection status, speeds, and mode information:
- SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps
- L/A (link/activity) - Green LED lights On when the Ethernet cables are
connected and terminated correctly, and blinks when receiving Ethernet
data packets
OVERVIEW
The NetLinx NXB-KNX Communications Gateway allows NetLinx
Integrated Controllers the ability to control, integrate and
communicate via a single common language. KNX is the world’s
first open, royalty free, and platform independent standard for
home and commercial building control.
COMMON APPLICATION
Ideal for building control, ranging from lighting and shade
control to various security systems, HVAC, water control, energy
management, metering as well as audio and more.
POWER
• PoE powered - no local Power Supply needed
• IEEE 802.3af Compliant
MEMORY
features
• 64 MB RAM
• 64 MB of RAM
• 256 MB of FLASH
• 256 MB FLASH
ENVIRONMENTAL
• Ethernet Interface to AMX control equipment
• 5mm Phoenix connector with screw retention to KNX network
• Transmit and receive LEDs showing KNX network communication
ONLINE www.amx.com/products/NXB-KNX.asp
• Operating Temperature: 32°F - 104°F (0°C - 40°C)
• Relative Humidity: 5% to 85% non-condensing
• Intended for indoor use only
CERTIFICATIONS
FCC Class B, CE, IEC60950, RoHS
INCLUDED ACCESSORIES
• Rubber feet
• Green 2-Pin 5mm Phoenix connector with captive screws
A CLOSER LOOK
D e v ic e Status L ED s
2 - p in captive-wire connector for
c on t ro l i nt erfa ce
PoE Ethernet Port f o r
ne tw or k data/ power
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
PS-POE-AF PoE Injector (FG423-80)
www.amx.com/products/PS-POE-AF.asp
292
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
253
c e n t r a l CONTROLLERS
NXC-NH
NetLinx ICSNet Hub Card
(FG2060)
OVERVIEW
Designed for control systems of virtually any size, the NXC-NH
A CLOSER LOOK
NetLinx ICSNet Hub can expand control over long distances. The
I C S Hu b I N / O U T
C o n n ect o rs & L E D s
NXC-NH ICSNet Hub is engineered to distribute ICSP (Internet
Control System Protocol) data and NetLinx ICSNet control to
I C S Net OUT co n n ecto r s an d LEDs
the entire NetLinx Control System. ICSP Packets are transmitted
over various types of networks that include Internet, Ethernet and
NetLinx ICSNet control bus managed by the cards. Operating as
a dedicated control network, the ICSNet uses EchlonTM Neuron©
technology to transmit high-speed data.
Po w er S u p p l y i n d i cato r LED (g r een )
1 2 V DC Po w er S u p p l y co n n ecto r
FEATURES
• Distributes ICSNet data and power to other NetLinx devices
• Manages up to 8 independent ICSNet wiring runs
• Handles wiring runs of up to 1,000 feet for each ICSNet run
SPECIFICATIONS
• Links to NetLinx Master and Hubs via ICSHub networking
DIMENSIONS (HWD)
to 1,000 feet
• 1 5/16” x 5” x 8 13/16” (3.4 cm x 12.7 cm x 22.4 cm)
• RU: 1
• Employs industry-standard CAT-5 wiring and connections
WEIGHT
• Accepts ICSHub data, regenerates new ICSHub data link for up
• Available to install in NXF NetLinx CardFrame, NXI or in NXS-
POWER
MHS Module enclosure
180 mA @ 12 VDC
rear panel components
ONLINE www.amx.com/products/NXC-NH.asp
254
26 oz (737 g)
• POWER: 2-pin 12 VDC power terminal
• ICSNet: Eight RJ-45 jacks for ICSNet data and power; green LED flashes when
receiving data
• ICSHub: In and Out RJ-45 jacks for ICSHub data and power; yellow LED flashes
when receiving data
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
PSN6.5
PSN4.4 PSN2.8
6.5 Amp Power Supply 4.4 Amp Power Supply 13.5 VDC, 2.8 A Power Supply
(FG423-41)
(FG423-45)
(FG423-17)
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/PSN2.8.asp
291
290
289
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NXC-HE
NetLinx ICSHub Expander Card
(FG2062)
OVERVIEW
The NXC-HE ICSHub Expander Card can be used as an ICS hub
A CLOSER LOOK
cable extender when runs between ICS hubs are more than 1,000
I C S Hu b I N / O U T
C o n n ect o rs & L E D s
feet. The NXC-HE Card can also be used in place of a Master
Card in a NXI NetLinx Integrated Controller or NXF (CardFrame).
Po w er S u p p l y i n d i cato r LED (g r een )
FEATURES
• Links to NetLinx Master and Hubs via ICSHub networking
• Available to install in NXF NetLinx CardFrame or NXI
Integrated Controller
1 2 V DC Po w er S u p p l y co n n ecto r
ONLINE www.amx.com/products/NXC-HE.asp
QU IC K T IP
The NXC-HE Card can also be used in place of a Master Card in
the N X I NetLinx Integra te d Co n tro l l e r
SPECIFICATIONS
DIMENSIONS (HWD)
• 1 5/16” x 5” x 8 13/16” (3.4 cm x 12.7 cm x 22.4 cm)
• RU: 1
WEIGHT
26 oz (737 g)
POWER
110 mA @ 12 VDC
ICSHub IN/OUT
• RJ-45 connectors that supply data to other Hubs connected to the Master Card,
and wired using a daisy-chain configuration. The ICSHub OUT connector of one
Hub must be connected to the ICSHub IN connector on the downstream Hub
• Yellow LEDs blink when receiving data on the associated IN/OUT ports.
rear panel components
• POWER: 2-pin 12 VDC power terminal
• ICSHub: Two RJ-45 jacks for ICSHub In/Out data and power, yellow LED flashes
when receiving data
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
PSN6.5
PSN4.4 PSN2.8
6.5 Amp Power Supply 4.4 Amp Power Supply 13.5 VDC, 2.8 A Power Supply
(FG423-41)
(FG423-45)
(FG423-17)
www.amx.com/products/PSN6.5.asp
www.amx.com/products/PSN4.4.asp
www.amx.com/products/PSN2.8.asp
291
290
289
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
255
c e n t r a l CONTROLLERS
NXS-MHS
Master/Hub Module Shell
(FG2009)
OVERVIEW
The NXS-MHS Master/Hub Module Shell is the enclosure for the
NetLinx Processor ICSNet and ICSHub Cards. The NXS-MHS
A CLOSER LOOK
accommodates one card and comes complete with faceplates for
the Master and the Hub.
Eth er n et 1 0 /1 0 0 LEDs
ONLINE www.amx.com/products/NXS-MHS.asp
Eth er n et 1 0 /1 0 0
C o n n ecto r
I C S Net co n n e c t o rs / L E D s
ICSHub IN/OUT
C o n n e c t o r/ L E D s
NXC-M E260
ETHERNET
10/100
TX
FD
CTS
PW R
AXP
RTS
1 2 V DC p o w er
co n n ecto r
• 1 1/2” x 5 9/16” x 8 3/4” (3.8 cm x 14.1 cm x 22.2 cm)
• RU: 1
GN D
12VDC
DIMENSIONS (HWD)
AXM
SPEED
RX
M aster-Ethernet
IN
GN D
SPECIFICATIONS
O UT
PW R
AXlink
PRO GRAM
ICSNet
ICSHub
P r o g r am Po r t C o n n ect o r
WEIGHT
1.4 lbs (630 g)
Ax Li n k co n n ecto r
Ex p an s i o n Ou t co n n ecto r
Ax Li n k s tatu s LED (g r een )
enclosure
Metal with black matte finish
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
NXC-NH
NXC-HE
ICSNet Hub Card ICSHub Expander Card
(FG2060)
(FG2062)
www.amx.com/products/NXC-NH.asp
www.amx.com/products/NXC-HE.asp
254
255
NXS-NMS
SPECIFICATIONS
NetModule Shell
DIMENSIONS (HWD)
• 1 1/2” x 5 9/16” x 9 1/4” (3.8 cm x 14.1 cm x 23.5 cm)
• RU: 1
(FG2009-10)
WEIGHT
2.15 lbs (980 g)
OVERVIEW
With the NXS-NMS NetModule Shell, one NetLinx Control Card
can be installed, providing connectivity to the NetLinx bus via
power
+12 VDC
ICSNet connections. The NXS-NMS is a simple, economical option
for integrating additional functionality into control systems, and it
QUI C K T I P
T h e I D b u t t o n o n t h e re a r p a n e l c a n b e p r o g ra m m e d w i t h t h e
N e t L i n x S t u d i o s o f t wa re t o a s s i g n n e w D e v i c e a n d S y s t e m
num ber s for the m odul e.
provides an enclosure for installing NetLinx (NXC) Control Cards.
features
• Control connector: 20-pin black (male) connector that connects
the NetModule Shell to external devices. These connectors are
C o n tr o l C ar d con n e c t o r ( 2 0 - p in )
A CLOSER LOOK
keyed to ensure proper installation
NetLinx Master/Hub ICSNet Port. An ICSNet port on a NetLinx
Master or Hub supplies up to 500 mA at 12 V for module power
I C S Net RJ-4 5 c o n n e c t o rs
Pa ra lle l 1 2 V D C
2 - p in p o we r
s u p p ly c o n n e c t o rs
• ICSNet RJ-45 connectors: Receives power and data from a
S
• 12 VDC power supply connectors: Two male 2-pin (green)
connectors for 12 VDC power
ONLINE www.amx.com/products/NXS-NMS.asp
256
I D Bu tto n
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NXC-IRS4
4-Port IR/S Card, 4 IR/S
and 4 Inputs
(FG2023)
OVERVIEW
SPECIFICATIONS
The NXC-IRS4 4-Port IR/S Card provides four IR/Serial input
IR 1-4
control ports with LED status feedback. Each port in the NXC-IRS4
4 IR/IR Serial control ports 20 KHz-1.14 MHz
stores programmed commands for IR or serial-controlled devices.
INPUT 1-4
The NXC-IRS4 Card can be used for stand-alone operation in
the NXS-NMS NetModule Shell or in conjunction with up to 12
Control Cards in the NXF NetLinx CardFrame. NetLinx Control
Cards provide flexible, modular building blocks for creating
4 I/O ports for closure or 0-5 VDC sensing, 200 mA
POWER
+12 VDC power for sensors
STATUS 1-10
advanced control applications. With a full array of LED status
2 LEDs for each channel, Red LED for IR transmission, Yellow LED for input
status, Green ICSP status LED
indicators at the front, the LEDs are easily viewed from the
WIRING
NetLinx enclosure’s translucent cover. Whether in a CardFrame or
3.5mm captive-screw terminals
NetModule, NetLinx Control Cards operate directly on the high-
MODELS
speed ICSNet data bus.
NXC-IRS4 4-Port IR/S Card
HOUSING
features
• Provides four IR/IR Serial control ports and front-panel
• NXF NetLinx CardFrame
• NXS-NMS NetModule Shell
status feedback
• Includes four inputs for sensed power control
ONLINE www.amx.com/products/NXC-IRS4.asp
A CLOSER LOOK
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
NXF
NXS-NMS
NetLinx CardFrame NetModule Shell
(FG2001)
(FG2009-10)
www.amx.com/products/NXF.asp
www.amx.com/products/NXS-NMS.asp
250
256
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
257
c e n t r a l CONTROLLERS
NXC-COM2
Dual COM Port Card,
2 RS-232/422/485
(FG2022)
OVERVIEW
SPECIFICATIONS
The NXC-COM2 Dual COM Port Card provides two RS-232,
power
RS-422, or RS-485 control ports and LED feedback for remote
140 mA @ 12 VDC
sources connected to the NXF NetLinx CardFrame, NI-4000 or
operation
NXS-NMS NetModule Shell. The NXC-COM2 can be used for
stand-alone operation in the NXS-NMS NetModule Shell or
in conjunction with up to 12 Control Cards in the NXF NetLinx
CardFrame. NetLinx Control Cards provide flexible, modular
building blocks for creating advanced control applications. With a
full array of LED status indicators at the front, the LEDs are easily
viewed from the NetLinx enclosure’s translucent cover. Whether
in a CardFrame or NetModule, NetLinx Control Cards operate
directly on the high-speed ICSNet data bus.
features
Data 1-2: Two RS-232/422/485 control ports, supports XON/XOFF, CTS/RTS,
300-230,400 baud
STATUS LEDs (2 per channel)
• Red LED shows TX (transmit) data activity
• Yellow LED shows RX (receive) data activity
- LED 1: CH1 TX (red)
- LED 2: CH1 RX (yellow)
- LED 3: CH2 TX (red)
- LED 4: CH2 RX (yellow)
• Green ICSP status LED (located on the board):
- On = card is not in communication with the Master.
- Blinks (1-second intervals) during normal operation.
CONNECTIONS/WIRING
Two 10-pin 3.5 mm captive-screw terminals
Provides two RS-232/422/485 data control ports and
DEVICE_ID
front-panel feedback
$0107
ONLINE www.amx.com/products/NXC-COM2.asp
A CLOSER LOOK
ICSN ET Status L ED
L ED 1
L ED 4
258
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
NXF
NXS-NMS
NetLinx CardFrame NetModule Shell
(FG2001)
(FG2009-10)
www.amx.com/products/NXF.asp
www.amx.com/products/NXS-NMS.asp
250
256
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NXC-VAI4
Voltage Output/Analog Input Card
(FG2025)
OVERVIEW
SPECIFICATIONS
The NXC-VAI4 Analog Voltage Card is equipped with four
POWER
independent analog-to-digital inputs and four independent
330 mA @ 12 VDC
digital-to-analog outputs, which are controllable over the ICSP
INPUTS
network. Each port can be configured for a variety of DC input
and output signals. NetLinx Control Cards provide flexible,
modular building blocks for creating advanced
control applications.
Four high-impedance analog DC inputs
OUTPUTS
Four analog DC outputs (user-configurable)
D/A - A/D CONVERSION
A/D and D/A converters for analog sampling and control. 8 or 10-bit; userselectable via the ADMODE Send_Command
FEATURES
AVAILABLE INPUT VOLTAGES
• Inputs: Four high-impedance analog DC inputs
0 V to +12 V
• Outputs: Four analog DC outputs (user-configurable)
AVAILABLE OUTPUT VOLTAGES
• D/A, A/D conversion: A/D and D/A converters for analog
• 12 V to +12 V: The output voltage may be software-configured for any min. and
max. levels between -12 and +12 VDC.
- Maximum output current = 60 mA
- Over-voltage protection to +28 VDC
• External reference: A user supplied external reference voltage can be used to
set the maximum voltage range for the D/A outputs. The full analog output
range is scaled to fit the maximum range set by the external reference. Output
voltage may be set to any level between 0-12 VDC, referenced to the external
reference voltage input and NXC-VAI4 power supply GND
• External reference input: (EREF - one for each output)
- Maximum external reference input voltage = +12 VDC
- Over-voltage protection to +28 VDC
• Internal reference output: (IREF)
- +5 V reference output, maximum current = 60 mA
- This output is intended to drive a ground-referenced load
sampling and control 8- or 10-bit; user selectable
• Available input voltages: 0 V to +12 V
• Available output voltages: -12 V to +12 V
• The output voltage may be software-configured for any
minimum and maximum levels between -12 and +12 VDC
• Maximum output current = 60 mA
• Over-voltage protection to +28 VDC
ONLINE www.amx.com/products/NXC-VAI4.asp
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
NXF
NXS-NMS
NetLinx CardFrame NetModule Shell
(FG2001)
(FG2009-10)
www.amx.com/products/NXF.asp
www.amx.com/products/NXS-NMS.asp
250
256
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
259
c e n t r a l CONTROLLERS
NXC-VOL4
Volume Card, 4 Channels
(FG2024)
OVERVIEW
SPECIFICATIONS
The NXC-VOL4 Volume Card offers four discrete volume control
POWER
channels with LED feedback and is programmable for mono or
197 mA @ 12 VDC
stereo operation, and balanced or unbalanced audio connections.
VOLUME 1-4
A variety of features can be programmed such as audio levels,
audio mute, variable ramp speeds and preset levels. Use the
on-board jumpers to set the gain/attenuation (Unity, Pro level
(+4 dBu) to Consumer level (-10 dBu) conversion, or Consumer
level to Pro level on each channel). NetLinx Control Cards provide
flexible, modular building blocks for creating advanced control
applications.
FEATURES
• Provides four line-level audio volume channels and
front-panel feedback
• Supports balanced and unbalanced applications
ONLINE www.amx.com/products/NXC-VOL4.asp
Four volume channels
STATUS 1-4 (3 LEDS PER CHANNEL)
• Yellow LED shows level-up/down activity
• Red LED shows mute mode
- LED 1: Channel 1 RAISE (yellow)
- LED 2: Channel 1 LOWER (yellow)
- LED 3: Channel 1 MUTE (red)
- LED 4: Channel 2 RAISE (yellow)
- LED 5: Channel 2 LOWER (yellow)
- LED 6: Channel 2 MUTE (red)
- LED 7: Channel 3 RAISE (yellow)
- LED 8: Channel 3 LOWER (yellow)
- LED 9: Channel 3 MUTE (red)
- LED 10: Channel 4 RAISE (yellow)
- LED 11: Channel 4 LOWER (yellow)
- LED 12: Channel 4 MUTE (red)
GAIN JUMPERS 1-4
• Unity: Maximum Input Level: +10dBm
• Pro level to Consumer level conversion (attenuation of +4dBu IN to -10dBu
OUT), maximum Input Level: +10dBm
• Consumer level to Pro level conversion (gain of -10dBu IN to +4dBu OUT),
maximum Input Level: +6dBm
CONNECTIONS/WIRING
Two 10-pin 3.5 mm captive-screw terminals
AUDIO SPECIFICATIONS
• Frequency response of 15 Hz - 25 KHz
• THD less than .005% at nominal output level
• S/N ratio greater than 100 dB (IHF A)
• Crosstalk less than 80 dB
• Logarithmic attenuation range of 95 dB
260
RECOMMENDED ACCESSORIES
DESCRIPTION
PART #
ONLINE
PAGE #
NXF
NXS-NMS
NetLinx CardFrame NetModule Shell
(FG2001)
(FG2009-10)
www.amx.com/products/NXF.asp
www.amx.com/products/NXS-NMS.asp
250
256
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NXC-REL10
Relay Card, 10 Channels
(FG2020)
OVERVIEW
SPECIFICATIONS
The NXC-REL10 Relay Card provides 10 relays to support devices
POWER
that employ simple momentary or latching contact-closure control
260 mA @ 12 VDC (maximum)
with LED feedback.
OPERATION
COMMON APPLICATION
LEDs
Relays 1-10: ten relays, 1A @, 24VAC / 28VDC
Ideal for supporting devices in residential or commercial applications requiring momentary or latching contact-closure control.
FEATURES
Provides 10 isolated relays and front-panel LED feedback
10 red LEDs light to show ON status activity for each relay.
WIRING
• Two 10-pin 3.5 mm captive-screw terminals
• Commoning strip (metal)
DEVICE ID
$010a
ONLINE www.amx.com/products/NXC-REL10.asp
A CLOSER LOOK
NO and NC 3-pin
jumpe r s J 1 - J 5
N O and N C 3-pin jumper s J 6 - J 10
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
261
c e n t r a l CONTROLLERS
NXC-I/O10
Input/Output Card, 10 Channels
(FG2021)
OVERVIEW
SPECIFICATIONS
The NXC-I/O10 Input/Output Card provides 10 Input/Output
POWER
channels and LED feedback. It acts as a logic-level input and
180 mA @ 12 VDC (maximum)
responds to switch closures or voltage level (high/low) changes.
OPERATION
The Switch (SW) and Voltage (VO) modes are set with on-board
I/O 1-10: 10 Input/Output channels
STATUS LEDs
jumpers.
10 yellow LEDs light to show ON status activity (1 per channel)
N OTE: T h e I/Os o n t h is card ar e not dr y clos ur e; t hey ar e elec t r onic s w it c hes t ha t fl o a t
a t 5V w h e n Of f . T h e ref o re, t h e y s hould not be expec t ed t o w or k in s it ua t ions t ha t r e q u i r e
true d r y co n t a ct (o r d r y closu r e). The I/ O s w ill w or k w it h t he A M X P C 1 , P C 2 , U P C 2 0 a n d
UP C2 0+.
MODES
• Switch: Senses switch or relay contact closures or provides a logic-level output
• Voltage: Senses high- and low-voltage states
VOLTAGE CLAMP SETTINGS
COMMON APPLICATION
Ideal for supporting devices in residential or commercial
• 12 V mode (default): Clamps any voltage connected to I/O ports 1-10 to 12 V
• VO mode: Use for connections that will draw more than 12 V
applications requiring logic-level input from switch closures or
CONNECTIONS/WIRING
voltage level changes.
Two 10-pin 3.5 mm captive-screw terminals
DEVICE ID
$010b
FEATURES
• 10 Input/Output control channels and front-panel feedback
• Acts as logic-level switch or input; senses high and low voltage
states in voltage mode
ONLINE www.amx.com/products/NXC-I-O10.asp
V-C l am p +1 2 V /o p en j u m p er (j 3 1 )
A CLOSER LOOK
SW/ VO jumpe r s (J1 - J 15)
Status LED s
SW/ VO jumper s (J16 - J30)
262
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
AC-SMB
Surface Mounting Bracket
(FG525)
OVERVIEW
These L-shaped brackets can be oriented to align flush with either
with NI-700/900 controllers, MAX-CSE, MAX-CSD10, NXA-AVB
the top or bottom surface and allow users to mount devices to
and NXA-AVB/ETHERNET.
almost any flat surface; floor, ceiling, wall, table or wherever is
convenient for an installation. AC-SMB brackets can be used
ONLINE www.amx.com/products/AC-SMB.asp
AC-PMB
Pole Mounting Bracket
(FG531)
OVERVIEW
These brackets allow users to mount devices to a pole, such as
ONLINE www.amx.com/products/AC-PMB.asp
the poles used to mount display devices. Use the AC-PMB brackets with NI-700/900 controllers, MAX-CSE, MAX-CSD10, NXA-AVB
and NXA-AVB/ETHERNET.
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
263
c e n t r a l CONTROLLERS
AC-RK
SPECIFICATIONS
Accessory Rack Kit
DIMENSIONS (HWD)
• 1 3/4” x 19” x 1/2” (4.4 cm x 48.3 cm x 1.3 cm)
• RU: 1
(FG515)
T RAI NI NG AVAI LABLE
Fo r i m po rt a nt i nst a l l a t i o n, c o nf i gura t i o n a nd pro g r a m m in g t e ch n iq u e s ,
A M X U ni v e rsi t y t ra i ni ng i s a v a i l a bl e . J ust v i si t ww w.a mx.c o m/ p r o d u c t s/
A C -R K . as p a nd cl i c k o n t he “Tra i ni ng” t a b.
OVERVIEW
The Accessory Rack Kit holds up to three NetLinx modules and
measures only one rack unit in height.
ONLINE www.amx.com/products/AC-RK.asp
264
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NXP-CPI16
NetLinx Custom Panel Interface
®
(FG2410)
OVERVIEW
SPECIFICATIONS
The NetLinx Custom Panel Interface provides a direct ICSNet
DIMENSIONS (HWD)
connection to custom control panels. It’s pin-for-pin compatible
2 3/4” x 1 7/8” x 1 3/8” (7.0 cm x 4.7 cm x 3.6 cm)
with devices that were designed for use with the AXP-CPI16 card
WEIGHT
(designed for integration with an Axcess Control System). Two 20pin headers provide ribbon cable wiring or direct-connect insertion to circuit boards, providing inputs for up to 16 closures and
16 feedback outputs for LEDs. Under software control, the LED
outputs can act as drivers to 8-segment bargraphs or as discrete
outputs for feedback. In addition, the NXC-CPI16 also includes
two quadrature inputs for mechanical or optical rotary encoders,
used to control variable levels such as volume and lights, or lens
focus and zoom.
• Device: 8.10 oz (229.6 g)
• Total Shipping: 1 lb (453.6 g)
POWER
12 VDC; maximum draw of 300 mA
INPUT CONNECTORS
• Indicator power: Two-pin 3.5 mm captive wire
• I/O Headers: Two 20-pin headers, 8 I/O channels each (16 closure inputs
activated with GND or TTL Low (< 0.8 V)). Open collector outputs (0-28 VDC).
Inputs are sampled approximately every 10 msec
• Rotary Encoder inputs: 2 Quadrature inputs on a 2 x 3 header (6-pin), two
encoder inputs (4-pin) with a +5 V supply pin (supplying up to 100 mA) and
a GND pin
COMMON APPLICATION
ICSNET
The NXP-CPI16 is a versatile, useful device for both custom panel
• Two RJ-45 connectors for ICSNet connection ID BUTTON
• Generates an event from the CPI16 to allow you to assign new device numbers
using the ID mode in NetLinx Studio
and contact-closure applications.
FEATURES
•Integrates custom panels with 16 closure inputs and 16 LED
outputs; pin-for-pin compatible with panels designed for
LED
ICSP status indicator (green)
OPEN COLLECTOR OUTPUTS
•Operates as a low-cost closure interface
• 16-open collector outputs, acting as a switch to ground, up to 100 mA.
• Outputs can be connected to voltages ranging between 0 and + 28 V.
• Each output is updated every 10 msec
•Acts as a driver for up to two 8-segment LED bargraphs; each
INCLUDED ACCESSORIES
AXP-CPI16
bargraph uses eight of the 16 LED outputs
•Allows precise digital control of up to two levels from
quadrature inputs
• 6-pin header with 3 feet (0.914) of ribbon cable
• Two mating 20-pin headers, each with 3 feet of ribbon cable attached
• One green 2-pin 3.5 mm pitch captive wire connector for external
indicator power
•Accepts mechanical or optical rotary encoders
•Offers programmable level response, provides software-driven
performance adjustment and switchable coarse/fine level control
ONLINE www.amx.com/products/NXP-CPI16.asp
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
265
c e n t r a l CONTROLLERS
NXA-CFNI
CompactFlash Upgrade for
NI-X000 Series Controllers
NXA-CFNI512M 512 MB CompactFlash Upgrade (FG2116-34)
NXA-CFNI1G 1 G CompactFlash Upgrade (FG2116-35)
ONLINE www.amx.com/products/NXA-CFNI.asp
OVERVIEW
The NXA-CFNI is the perfect solution when more program
memory is needed in your NI-2000, NI-3000, or NI-4000 NetLinx
controller. Choose from 512 MB or 1 G upgrades.
NXA-CF2NI
CompactFlash Upgrade for
NI-X100 Series Controllers
NXA-CF2NI512M 512 MB CompactFlash Upgrade (FG2116-48)
NXA-CF2NI1G 1 G CompactFlash Upgrade (FG2116-49)
ONLINE www.amx.com/products/NXA-CF2NI.asp
OVERVIEW
The NXA-CF2NI is the perfect solution when more program
memory is needed in your in your NI-2100, NI-3100, or NI-4100
NetLinx controller. Choose from 512 MB or 1 G upgrades.
NXA-CFM
CompactFlash Upgrade for
NXC-ME260/64
NXA-CFM512M 512 MB CompactFlash Upgrade
(FG2116-04)
NXA-CFM1G
1 G CompactFlash Upgrade (FG2116-05)
ONLINE www.amx.com/products/NXA-CFM.asp
OVERVIEW
The NXA-CFM is the perfect solution when more program memory is needed in your NXC-ME260/64 NetLinx controller. Choose
from 512 MB or 1 G upgrades.
266
US S A L ES A ND S U PPORT 8 0 0 . 2 2 2 . 0 1 9 3 • I NTER NATI ONA L S A L ES A ND S U PPORT +1 . 4 6 9 . 6 2 4 . 74 0 0 • www.a m x.c o m
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
c e n t r a l CONTROLLERS
NCK
NetLinx Connector Kit
(FG2902)
OVERVIEW
The NetLinx Connector Kit includes five (5) each of the following
mating connectors:
• 2-pin 3.5 mm mini-Phoenix female connector (green)
• 2-pin 3.5 mm mini-Phoenix female connector (black)
• 4-pin 3.5 mm mini-Phoenix female connector (black)
• 5-pin 3.5 mm mini-Phoenix female connector (gray)
• 8-pin 3.5 mm mini-Phoenix female connector (black)
• 10-pin 3.5 mm mini-Phoenix female connector (black)
ONLINE www.amx.com/products/NCK.asp
NXA-ICSNET
NetLinx ICSNet Communication
Network Card
(FG2105-10)
OVERVIEW
The optional ICSNet communication network card from AMX
provides the NI-2100 and NI-3100 NetLinx Integrated Controllers
optional ICSNet communication network capability.
features
• Easily installed and adds ICSNet capability instantly
• Comes standard and pre-installed with the NetLinx NI-2100/ICS,
NI-3100/ICS and NI-4100 Integrated Controllers
• Handles wiring runs of up to 1,000 feet for each ICSNet run
• Employs industry-standard CAT-5 wiring and connections
ONLINE www.amx.com/products/NXA-ICSNET.asp
SPECIFICATIONS
DIMENSIONS (HWD)
2 3/8” x 2 3/8” x 1 3/8” (6.1 cm x 6.1 cm x 3.6 cm)
WEIGHT
1.2 oz (34.02 g)
3000 R E S EARCH D RIVE, RICH ARDSON, TX 75082 • 800.222.0193 • 469.624.7 1 5 3 f a x • TEC H NI C A L S U PPORT 8 0 0 . 9 3 2 . 6 9 9 3
© January 2010 AMX. All rights reserved. AMX does not assume responsibility for any errors or omissions.
267
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF