Oceanic BioCube HQi Installation instructions
Add to my manuals
14 Pages
Coralife Bio Cube is an aquarium system that provides a suitable environment for aquatic life. It features a 26-gallon glass tank with dimensions of 20"l x 20.75"w x 19.25"h, providing ample space for fish and other aquatic creatures. The lighting system includes a 150 Watt, 14,000K, double-ended metal halide bulb that mimics natural sunlight, promoting optimal growth and health for corals and other photosynthetic organisms. The filtration system utilizes a 243 gph (920 L/H) pump to maintain water clarity and remove impurities.
advertisement
LIMITED WARRANTY
Oceanic warrants that this product shall be free from defective electrical components and leaks or cracks due to defects in materials or workmanship for a period of twelve months from the date of purchase.
If a defect is shown, Oceanic will, at Oceanic’s sole discretion, either repair or replace the product without charge. No cash refunds will be made. This warranty is provided solely to the original consumer purchaser of the product and may not be transferred or assigned.
This warranty does not apply to damage resulting from accident, misuse, abuse, lack of reasonable care, failure to follow safety and installation instructions, use of the product with non-standard electrical service, or any other defect not resulting from defects in the electrical components of the product or defects in materials or workmanship. This warranty will not be effective unless and until the Oceanic product is shown to have been used in accordance with the safety and installation instructions accompanying the product, including the requirement that the product be placed on a flat, level surface designed to support the product.
THIS CONSTITUTES OCEANIC’S ENTIRE WARRANTY AND OCEANIC MAKES NO OTHER
WARRANTIES, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT. OCEANIC
SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION,
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
IF OCEANIC CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS LIMITED
WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION
OF THIS WARRANTY.
OCEANIC IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL
THEORY. OCEANIC EXPRESSLY DISCLAIMS ALL ALLEGED DAMAGES FOR LOSS OF AQUATIC LIFE,
PERSONAL INJURY, AND/OR PROPERTY DAMAGE.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of implied warranties or conditions, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary by state or province.
Oceanic shall not have any obligations under this warranty unless the owner notifies Oceanic in writing of any alleged defect(s) within 30 days of discovery of the defect(s). Any notice to Oceanic must be delivered by United States or electronic mail to one of the following addresses:
U.S. Mail
Oceanic Systems
5401 W. Oakwood Park Drive
Franklin, Wisconsin 53132
Electronic Mail [email protected]
Oceanic shall be allowed a reasonable period of time to investigate any warranty claim and to perform any testing Oceanic deems necessary to determine the cause of the defect. This warranty shall be interpreted under the laws of the state of Wisconsin.
For additional information regarding this limited warranty, please contact us at the addresses above, or call us at 800-255-4527.
®
Owner’s Manual
PRODUCT SPECIFICATION
Glass Aquarium: Size 29
Net Volume: 26 Gallons
Dimension:
20"l x 20.75"w x 19.25"h
Lighting:
150 Watt, 14,000K, double-ended metal halide
Cooling Fans: 38 mm,
4,000 RPM
Pump Flow Rate:
243 gph (920 L/H)
TABLE OF CONTENTS
Page 4
Page 6
Important Safety Instructions
Grounding
Page 7
Page 18
BioCube HQI Assembly and Setup Instructions
Aqualight HQI Assembly and Setup Instructions
Page 26 BioCube HQI Maintenance
Back Cover Warranty and Contact Information
2 3
IMPORTANT
SAFETY INSTRUCTIONS
1. WARNING – To guard against injury, basic safety precautions should be observed, including the following:
READ AND FOLLOW
ALL SAFETY INSTRUCTIONS.
2. DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the appliance to an authorized service facility for service or discard the appliance:
A. If the appliance falls into the water, DO NOT reach for it! First unplug it and then retrieve it. If electrical components of the appliance get wet, unplug the appliance immediately.
B. If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source.
C. Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet.
D. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or damaged in any manner.
E. To avoid the possibility of the appliance plug or receptacle getting wet, position aquarium stand and tank to one side of a wall-mounted receptacle to prevent water from dripping onto the receptacle or plug. A “drip loop,” shown in figure below, should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. The “drip loop” is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water traveling along the cord and coming in contact with the receptacle (Figure A1). If the plug or receptacle does get wet, DO NOT unplug the cord. Disconnect the fuse or circuit breaker that supplies power to the appliance. Then, unplug and examine for presence of water in the receptacle.
3. Close supervision is necessary when any
FIGURE A1 appliance is used by or near children.
Appliance
4. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and the like.
5. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
6. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition.
7. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
8. Make sure an appliance mounted on a tank is securely installed before operating it.
9. Read and observe all the important notices on the appliance.
Aquarium
Power
Supply
Cord
Drip
Loop
4
10. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
11. For added safety, the fixture must be plugged into a receptacle controlled by a GFI (ground fault interrupter) circuit breaker. Device must be properly connected to a grounded three-prong receptacle.
12. Do not use this appliance in such a way that the vents are restricted or blocked. These vents are necessary to avoid overheating and ensure safe operating temperature.
13. This appliance is intended FOR HOUSEHOLD USE ONLY.
14. THIS APPLIANCE IS FOR USE OVER COVERED AQUARIUMS ONLY.
SAVE THESE INSTRUCTIONS!
IMPORTANT SAFETY INFORMATION:
Please read the following precautions before use!
1. To reduce the risk of electric shock, always unplug the pump and power cords before performing any maintenance.
2. Never allow small children to touch, climb-on, or play with the aquarium or its stand. Adult supervision is required.
3. Never place an aquarium on the floor, it can cause injury or become damaged.
4. Never set an aquarium on an unsturdy or unsupported structure, such as those which are unable to support the weight of a filled aquarium, are suspended, can rock or sway, can sag, or on wheels or allows the aquarium to overhang. These could cause the aquarium to leak, crack, or even fall over if a top heavy situation is created.
5. Aquarium supports that are less than 12" wide (front and back) should be fastened or tethered to a wall to prevent a top heavy or unstable condition.
6. Do not allow water pump to operate dry at any time.
7. Always observe proper maintenance to ensure optimal operation.
HANDLE WITH CARE!
Always handle aquarium with care to avoid personal injury.
1. Never lift or attempt to move an aquarium that is not completely empty.
2. Never lift an aquarium with wet hands.
3. Never attempt to lift an aquarium by grasping the upper edges of the frame or from the canopy.
4. Always lift or carry an empty aquarium by supporting it from the bottom of the tank.
AQUARIUM LOCATION
1. For best results, place an aquarium in a location best suited to support the total weight of the aquarium.
The filled weight of an aquarium is approximately 10-12 lbs. per gallon of water plus the weight of sand, gravel, rocks or decorations.
2. Always place an aquarium on a flat and level area.
3. Avoid placing an aquarium where it will receive direct sunlight. Full or even partial sunlight can cause algae growth.
4. Keep aquarium in a well ventilated area away from a heating or cooling vent.
5. Do not place near electronic components and systems (i.e. TV, stereo systems, etc.).
5
GROUNDING
Grounding Setup:
This appliance should be grounded to minimize the possibility of electric shock. This appliance is equipped with an electric cord having an equipment grounding conductor and a grounding type plug. The plug must be plugged into an outlet that is installed and grounded in accordance with all appropriate codes and ordinances.
This appliance is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in Figure A2.
Grounding Installation:
The green-colored ground terminal (screw, and the like) extending from the adapter must be fastened to a permanent ground such as a grounded outlet box.
1. Plug temporary adapter into two-pole outlet (Figure A4).
FIGURE A4
Two-Pole Receptacle
Temporary Adapter
Screw
FIGURE A2
Grounded Outlet
Grounded Plug
Grounding Pin
Rigid Ear
(Grounding Means)
Grounded Outlet
Box Cover
2. Insert screw through rigid ear on temporary adapter and into grounded outlet box
(Figure A5).
FIGURE A5
Grounded Plug
A temporary adaptor which looks like the adaptor shown (Figure A3) may be used to connect this plug to a two-pole receptacle as shown in Figure A4, if a grounded outlet is not available. The temporary adapter should be used only until a grounded outlet can be installed by a qualified electrician.
(Temporary adapter not included.)
Two-Pole
Receptacle
Temporary
Adapter
Rigid Ear
(Grounding
Means)
FIGURE A3
Temporary
Adapter
Grounded Outlet
Box Cover
6
Power Strip Setup:
1. If using a power strip, the ground connector must be plugged into a receptacle controlled by a GFI (ground fault interrupter) circuit breaker.
2. Make sure to place the power strip in a dry and safe area away from the aquarium in order to avoid moisture.
3. Place power strip in a secure and stable area so that it cannot fall into the aquarium or sump.
4. Make sure all receptacles are protected from water: splash, spilling and evaporation.
BioCube HQI
ASSEMBLY AND SETUP INSTRUCTIONS
7
8
9
10
4
5
6
7
1
2
3
BIOCUBE HQI PARTS DIAGRAM
11
12
13
7
8
9
10
11
12
13
Part #
1
2
3
4
5
6
BIOCUBE HQI
PARTS IDENTIFICATION
Description
Left Filtration Cover
Right Filtration Cover
Glass Canopy
Filter Cartridge
Overflow Tray
Output Elbow Attachment
Item #
82105
Flexible Tubing
Water Pump
Output Discharge Nozzle
BioCube Glass Aquarium
82007
BioCube Protein Skimmer
(see pages 10 and 11 for parts/identification)
82053
Refugium Strainer
Sponge Filter
8 9
6
9
10
4
7
8
2
3
4
5
PROTEIN SKIMMER DETAILED DIAGRAM
1
Part #
1
2
3
4
5
6
7
8
9
10
PROTEIN SKIMMER
PARTS IDENTIFICATION
Description
Collection Cup Lid
Collection Cup
Reaction Chamber Top
Suction Cup
Airstone
Reaction Chamber Assembly
Airline Tubing 7'
Air Pump
Inline Air Flow Valve
Check Valve
10 11
BIOCUBE PROTEIN SKIMMER SETUP
Protein Skimmer Assembly
(Figure C1)
1. Insert airline tubing into air pump using end that has just 6" before the inline air flow valve.
2. Remove reaction chamber top from reaction chamber and insert the other end of the airline tubing through the hole at the bottom of the reaction chamber.
3. Attach the airstone to the end of the airline tubing and pull it back through until the airstone is at the bottom of the reaction chamber.
4. Reassemble all parts of the protein skimmer, except for the collection cup.
Reaction Chamber Top
FIGURE C1
Airstone
BIOCUBE PROTEIN SKIMMER SETUP
(con't)
FIGURE C2
Protein Skimmer Placement
(Figure C2)
1. Using hanging clip on reaction chamber top, hang protein skimmer on the wall between chambers 1 and 2. NOTE: if skimmer is in correct position, the right filtration cover will fit properly.
Collection Cup Assembly
(Figure C3)
1. Place collection cup on top of reaction chamber. Pull airline tubing through the hole on the back of the right filtration cover, making certain that airflow is not restricted when the right filtration cover is on.
Protein Skimmer Startup
1. Once water has been added (page 23), plug in pump. Adjust airflow adjustment nozzle so that bubbles stay just above the reaction chamber.
2. When collection cup fills, remove and dispose of waste material by rinsing with warm water.
FIGURE C3
Reaction Chamber
6" Length of Airline Tubing
Inline Air Flow Valve
12 13
BIOCUBE FILTER SETUP
SAFETY:
1. Turn off all switches and unplug all power cords from outlet or power source before performing maintenance.
2. Visually inspect the aquarium and all parts prior to installation to make sure nothing has been damaged.
Filter Assembly and Setup
(Figure C4)
1. Remove left and right filtration covers, glass canopy and Aqualight HQI.
2. Place protein skimmer in chamber 1 after proper assembly and according to proper placement instructions (pages 20-21).
3. Remove filter cartridge from the overflow tray in chamber 2 and its packaging. Rinse thoroughly with cool freshwater and reinstall in the overflow tray.
4. Make sure that the overflow tray and refugium strainer are properly placed inside chamber 2.
5. Make sure that the sponge filter is correctly placed in chamber 3.
6. Make sure that the water pump is properly assembled and connected to the return output discharge nozzle.
Filter Cartridge
Overflow Tray
Protein Skimmer
Refugium Strainer
Water Pump
Sponge Filter
Aquarium Divider
Output Discharge
Nozzle
Surface Intake
Bottom Intake
FIGURE C4
CHAMBER
3
CHAMBER
2
CHAMBER
1
COMPLETED FILTER
ASSEMBLY
14
BIOCUBE FILTER STARTUP
Filter Startup Operation
(Figures C5 and C6)
1. Add substrate, rocks and décor to the aquarium.
2. Prepare saltwater for aquarium, making sure water is at room temperature.
3. Slowly add water to the aquarium. Make sure to fill aquarium to the lower edge of the top moulding (Figure C5).
4. Plug water pump cord into an outlet or power source. Pump will raise the water level in the aquarium section while draining into the filtration section (Figure C6).
5. Observe and make sure that the water circulation is flowing properly from the aquarium section into the filtration section.
6. Place glass top on aquarium.
7. Attach and plug in Aqualight HQI according to instructions (page 10).
8. Once aquarium and filtration have run for two days, and everything is functioning properly, add livestock to the aquarium.
Precautions for Optimal Filter
Performance
1. Do not block or obstruct output discharge nozzle.
2. Do not block or obstruct surface or bottom level intakes.
3. Perform scheduled maintenance and change filter cartridge as directed.
4. Observe scheduled maintenance on water pump.
5. Make sure to perform scheduled water changes and BioCube filter maintenance according to instructions (page 26).
FIGURE C5
Top Moulding
Fill
Level
Aquarium
Section
Filtration
Section
FIGURE C6
FILL LEVEL
AFTER FILTER STARTUP
Original
Fill Line
New
Fill Level
INITIAL
FILL LEVEL
Plug
In
Aquarium
Section
Filtration
Section
15
REFUGIUM SETUP AND REFUGIUM
LIGHT INSTALLATION
SAFETY:
1. Turn off all switches and unplug all power cords from outlet or power source before performing maintenance.
Refugium Setup With Refugium
Light (not included)
1. Remove left and right filtration covers.
2. Remove overflow tray and filter cartrige from center filter chamber.
3. Once the BioCube aquarium is fully set up and ready to support livestock, add substrate and macroalgae to the refugium chamber. Replace overflow tray, filter cartridge and left and right filtration covers.
Refugium Light Installation
(Figure C7)
1. Locate window on the back of the BioCube HQI.
2. Clean area around the illumination window with a dry cloth to remove any dust, salt or water.
3. Follow instructions included with the refugium light to mount to BioCube HQI.
FIGURE C7
16
BIOCUBE FILTER OPERATION
BioCube Filtration Stages
(Figures C8–C10)
1. Water flows from aquarium into the surface and bottom intakes into chamber 1 where some enters the protein skimmer
(Figure C8). The protein skimmer removes many harmful organic materials from the water.
FIGURE C8
2. From chamber 1, water flows over the top of and through the filter cartridge into the refugium in chamber 2 (Figure C9).
Live macroalgae and live rock in the refugium remove excess nutrients and add oxygen to the water while helping stabilize the pH level.
FIGURE C9
3. From the refugium, water flows into chamber 3 through the sponge filter and into the water pump (Figure C10).
The water pump then forces the water through the flexible tubing and back into the aquarium through the discharge nozzle.
FIGURE C10
17
Aqualight HQI
ASSEMBLY AND SETUP INSTRUCTIONS
18
1
6
7
8
9
2
3
4
5
10
11
12
13
14
AQUALIGHT HQI PARTS DIAGRAM
16
17
15
18
19
19
7
8
9
10
11
12
13
14
Part #
1
2
3
4
5
6
15
16
17
18
19
AQUALIGHT HQI PARTS
IDENTIFICATION
Description
Aqualight Lighting Hood
Lamp Holder
Angle Adjustment Knob
Male (A) Connection Knob
Side End Panel
HQI Glass Lens Cover
Double-Ended HQI Metal Halide Lamp
Extension Arm
Ventilation Grill
Height Adjustment Knob
Female (B) Connection Knob
Hang-On Tank Mount Base
Tank Mount Bracket
Tank Mount Screws (3)
Extension Adjustment Knob
Ballast Connection
Cooling Fan Connection
HQI Metal Halide Ballast
Cooling Fan Adaptor
20
ASSEMBLY AND MOUNTING
WARNING:
1. This fixture is for use over covered aquariums only.
2. Always turn fixture off and unplug ballast power cord before adjusting fixture or replacing lamps. Let the fixture cool down before handling.
3. Do not attach fixture to ballast until all assembly connections, adjustments and mounting setups are completely performed.
FIGURE B1
Aqualight HQI Mounting
(Figures B1 and B2)
1. Place Aqualight tank mount bracket between the two rear filtration covers
(Figure B1).
2. Hold the tank mount bracket in place and remove the two rear filtration covers.
3. Continue to hold tank mount bracket in place and fasten tank mount screws
(Figure B2). Hand tighten tank mount screws until tank mount bracket is securely in place.
Aqualight HQI Fixture Assembly
(Figure B3)
1. Connect lighting hood (Connection A), with male connection knob to tank mount bracket (Connection B), with female connection knob using height adjustment knob.
2. Screw height adjustment knob through
Connection B and into Connection A.
3. Adjust and secure connection.
Safety Precautions:
1. Do not plug BioCube into an outlet or power source until setup and installation is completed.
2. Visually inspect the aquarium and canopy prior to installation to make sure it has not been damaged.
FIGURE B2
FIGURE B3
Connection A
Connection B
21
Molding
Tank Mount
Screws (3)
Glass
AQUALIGHT ADJUSTMENTS
SAFETY:
1. Turn off switch, unplug ballast power cord and allow fixture to cool down before handling.
2. Do not let the top lighting hood come into direct contact with water.
FIGURE B4
Extension Adjustment
Extension Adjustment (Figure B4)
1. Loosen extension adjustment knob.
2. Adjust extension arm to desired position.
3. Hand tighten extension adjustment knob firmly. Make sure that the fixture is tightened securely in place.
Height Adjustment (Figure B5)
1. Loosen height adjustment knob until extension arm moves freely.
2. Adjust top lighting hood to desired position.
3. Hand tighten height adjustment knob firmly.
Make sure that the fixture is tightened securely in place.
Angle Adjustment (Figure B6)
1. Loosen angle adjustment knobs.
2. Adjust top lighting hood to desired position.
3. Hand tighten angle adjustment knobs firmly.
Make sure that the fixture is tightened securely in place.
FIGURE B5
Height Adjustment
FIGURE B6
Angle Adjustment
22
BALLAST AND COOLING FAN SETUP
IMPORTANT SAFETY NOTES:
1. Make sure to follow the fixture and HQI ballast connection instructions in their entirety. Failure to follow these directions may damage ballast and/or cause failure.
2. Turn off all switches and unplug all power cords from power outlet(s). Do not plug power cords into power outlets until fixture installation and setup is complete.
Ballast Setup (Figure B7)
1. Locate double-ended HQI metal halide lamp connector on unit.
2. Make sure that the double-ended HQI metal halide ballast is unplugged and switch is in the "off" position.
3. Align the male pins on the double-ended
HQI metal halide lamp connector with the female pin inlets on the double-ended
HQI metal halide ballast connector and connect. IMPORTANT! Make sure that the lamp connector is fully seated into the ballast connector.
Mounting HQI Ballast (Figure B8)
THIS STEP IS OPTIONAL
1. Slide out ballast-mounting bracket.
2. Place metal washer between screw and ballast mounting bracket. Tighten screw until secure (mounting hardware not included).
Cooling Fan Setup (Figure B9)
1. Locate cooling fan connector on fixture.
2. Attach cooling fan connector to cooling fan adaptor.
FIGURE B7
MALE FEMALE
Double-ended
HQI Metal Halide
Lamp Connector
Ballast
Mounting
Hardware
Double-ended
HQI Metal Halide
Ballast Connector
FIGURE B8
FIGURE B9
Cooling Fan
Connector
23
Cooling Fan
Adaptor
OPERATION
Startup Operation
1. Make sure all connections are completely attached and secure.
2. Make sure that all switches are in the off position before plugging in power cords to power source .
3. Plug double-ended HQI metal halide ballast power cord into an outlet or power source and turn the switch on.
NOTE: It may take 5-10 minutes for double-ended HQI metal halide lamp to reach maximum light intensity.
CAUTION: When the double-ended HQI metal halide ballast is turned off, wait until the double-ended HQI metal halide lamp has completely cooled before turning ballast back on. Lamp may not turn on if not completely cooled.
4. Verify that the lamp is lit and functioning properly.
5. Plug cooling fan power cord into an outlet or power source and turn the switch on.
NOTE: Cooling fan must be on while lamp is on.
6. Make sure cooling fans are on and are blowing freely across the unit.
24
LAMP REPLACEMENT
SAFETY:
1. Turn off all switches and unplug all power cords from outlet or power source before performing maintenance.
2. Make sure the unit is cool before handling.
Double-Ended HQI Metal Halide
Lamp Replacement
(Figures B10–B12)
1. Remove the fixture from the aquarium.
2. Place fixture on a non-abrasive flat surface with the bottom facing up.
3. Remove the side panel (Figure B10).
NOTE: side end panel is located at the end of the fixture, opposite the cooling fan.
4. Slide ventilation grill off of the fixture
(Figure B10).
5. Detach glass lens cover from the lamp holder by pushing the cover into the opposite end to free one side of the cover from the cover clamps (Figure B11).
6. Use a soft cloth to grab one end of the lamp. Push the lamp into the opposite end to free one side of the lamp from the double-ended HQI metal halide socket
(Figure B12).
7. Gently lift the lamp up at an angle and remove the lamp (Figure B12).
8. Carefully install replacement double-ended
HQI metal halide lamp using a soft cloth.
9. Replace all light fixture parts.
WARNING: Do not touch double-ended HQI metal halide lamp with fingers, as the oils may damage the lamp. If contact is made with the lamp, use a clean, soft, dry cloth to remove any fingerprints from the lamp before use.
FIGURE B10
Aqualight Hood Ventilation
Grid
PRESS IN
FIGURE B11
HQI Glass Lens Cover
Lamp Holder
FIGURE B12
PRESS IN
Side End
Panel
LIFT UP
Use Soft
Cloth LIFT UP
Lamp Holder
25
BIOCUBE MAINTENANCE
WARNING!
1. Make sure all switches are in the off position and unplug power cords from power source or outlet before performing maintenance.
2. Wash hands thoroughly with soap and water before performing maintenance to avoid contamination of the aquarium.
Daily Maintenance (Figure C11)
1. Visually observe the BioCube lighting and filtration to make sure that the system is functioning properly.
2. Check water level. Make sure to replace evaporated water with freshwater to replenish water supply. Do not let water get below the minimum water level.
Weekly Maintenance
1. Keep BioCube surfaces clean from dust and debris. Wipe exposed surfaces with a clean and dampened soft terrycloth.
2. Remove glass top and wipe down with a dampened soft terrycloth to remove salt buildup.
3. Inspect filtration system for clogging and excessive accumulation of debris. Clean and remove debris from surface and bottom intakes and overflow tray. Rinse parts in freshwater if needed.
FIGURE C11
Minimum
Water Level
26
BIOCUBE MAINTENANCE
(con't)
Monthly Maintenance
(Figures C12–C14)
1. Replace used filter cartridge by tilting the filter back from one end of the overflow tray, then pulling out. Discard. Rinse new filter cartridge with freshwater before installing (Figure C12).
2. Remove sponge filter from water pump.
Rinse and clean sponge with cool freshwater to remove accumulated organic buildup (Figure C13).
3. Disconnect water pump from output elbow attachment and flexible tubing. Disassemble pump and impeller. Rinse and wipe down all parts to dislodge debris. If calcium buildup is present, soak in a vinegar solution with one part vinegar to one part water for one hour, then rinse thoroughly.
4. Disassemble pump and impeller. Rinse and wipe down all parts to dislodge debris and particulate matter (Figure C14).
9–12 Month Maintenance
1. Replace Aqualight HQI metal halide bulb every 9-12 months by following the lamp replacement instructions on page 14.
For optimal performance, always use
Coralife brand 150 Watt Double-Ended
HQI replacement lamps.
FIGURE C14
u p
FIGURE C12
Filter Cartridge
Overflow Tray
Sponge Filter
Pull a way
FIGURE C13
Pump Housing Pump Impeller
27
Ceramic Shaft Impeller Cover
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project