Advertisement
Advertisement
Operating Instructions (ENG)
MODELS: C2
10075170
10075210
C2H
10075190
10075220 10075260
Read instructions before operating the machine.
T
86038850 07/17/09
PRV NO. 98925
MACHINE DATA LOG/OVERVIEW
MODEL _______________________________________
DATE OF PURCHASE __________________________
SERIAL NUMBER ______________________________
SALES REPRESENTATIVE # _____________________
DEALER NAME ________________________________
OPERATIONS GUIDE NUMBER ___________________
PUBLISHED __________________________________________
YOUR DEALER
Name: __________________________________________________________________________________________________
Address: _______________________________________________________________________________________________
For the name and address of your dealer contact: Windsor Industries
Phone Number: _________________________________________________________________________________________
2 CHEYENNE 86038850 03/08/07
Machine Data Log/Overview.........................2
Table of Contents..........................................3
HOW TO USE THIS MANUAL
How to use this Manual.................................1-1
SAFETY
Important Safety Instructions ........................2-1
Hazard Intensity Level. .................................2-2
Grounding Instructions..................................2-3
OPERATIONS
Technical Specifications. ..............................3-1
Controls.........................................................3-2
Machine Operation........................................3-3
Pre-Run Machine Inspection......................3-3
Equipment Set-up ......................................3-3
Cleaning & Emptying Tanks.......................3-3
Shut Down and Storage.............................3-4
MAINTENANCE
Maintenance .................................................4-1
Daily Maintenance. ....................................4-1
Periodic Maintenance. ...............................4-1
Monthly Maintenance.................................4-1
Semi-Annually............................................4-1
Lubrication .................................................4-1
Storage. .....................................................4-1
Solution Pump Replacement. .......................4-2
Vacuum Motor Replacement ........................4-2
Vacuum Carbon Brush Replacement. ..........4-2
Pump Replacement Parts. ............................4-3
Pressure Regulator. ......................................4-4
Machine Troubleshooting..............................4-5
CHEYENNE 86038850 03/08/07
TABLE OF CONTENTS
GROUP PARTS LIST
Base Group................................................... 5-1
Solution Tank Group................................... .5-3
Pump Group 100 PSI
No Heat 2 St Vac ...................................... 5-5
Pump Group 100 PSI
No Heat 3 St Vac ....................................... 5-7
Pump Group 100 PSI
With Heat 2 St Vac .................................... 5-9
Pump Group 200 PSI
No Heat 3 St Vac. .................................... 5-11
Pump Group 200 PSI
With Heat 7.2 3 St Vac. ........................... 5-13
Recovery Tank Group-2 St. ........................ 5-15
Recovery Tank Group-3 St. ........................ 5-17
Recovery Tank Group- 2 St With Heat ....... 5-19
Recovery Tank Group-3 St With Heat ........ 5-21
Vacuum Group-2 St .................................... 5-23
Vacuum Group-3 St .................................... 5-25
Vacuum Group-7.2-3 St.............................. 5-27
Heater Group…………………………………5-29
Tank & Lid Group........................................ 5-31
Label and Strap Group ............................... 5-33
Wiring Group 100-PSI 2 St Vac .................. 5-35
Wiring Group 100-PSI 3 St Vac .................. 5-36
Wiring Group 200 PSI 3 St Vac .................. 5-37
Wiring Group 200 PSI-7.2-3 St Vac............ 5-38
Wiring Group Heater................................... 5-39
Notes .......................................................... 5-40
Warranty ........................................... ……...5-41
3
This manual contains the following sections:
- HOW TO USE THIS MANUAL
- SAFETY
- OPERATIONS
- MAINTENANCE
- PARTS LIST
The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
Parts may be ordered from authorized dealers.
When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine. The MACHINE
DATA box is located on the inside of the front cover of this manual.
MODEL _____________________________________
DATE OF PURCHASE ________________________
SERIAL NUMBER ____________________________
SALES REPRESENTATIVE # ___________________
DEALER NAME ______________________________
OPERATIONS GUIDE NUMBER __________________
PUBLISHED ________________________________
The model and serial number of your machine is located on the inner wall of solution tank, above the pump.
1-1 CHEYENNE 86038850 03/08/07
HOW TO USE THIS MANUAL
The SAFETY section contains important information regarding hazard or unsafe practices of the machine. Levels of hazards is identified that could result in product or personal injury, or severe injury resulting in death.
The OPERATIONS section is to familiarize the operator with the operation and function of the machine.
The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition.
The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information:
- REF – column refers to the reference number on the parts illustration.
- PART NO. – column lists the part number for the part.
- PRV NO. – reference number.
- QTY – column lists the quantity of the part used in that area of the machine.
- DESCRIPTION – column is a brief description of the part.
- SERIAL NO. FROM – column indicates the first machine the part number is applicable to. When the machine design has changed, this column will indicate serial number of applicable machine.
The main illustration shows the most current design of the machine. The boxed illustrations show older designs. If column has an asterisk (*), call manufacturer for serial number.
- NOTES – column for information not noted by the other columns.
NOTE: If a service or option kit is installed on your machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement
parts numbers needed for ordering future parts.
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precaution must always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
!
WARNING:
To reduce the risk of fire, electric shock, or injury:
Use only indoors. Do not use outdoors or expose to rain.
Use only as described in this manual. Use only manufacturer’s recommended components and attachments.
If the machine is not working properly, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center.
Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow.
This machine is not suitable for picking up hazardous dust.
Machine can cause a fire when operating near flammable vapors or materials. Do not operate this machine near flammable fluids, dust or vapors.
This machine is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices for more than normal housekeeping purposes.
Maintenance and repairs must be done by qualified personnel.
During operation, attention shall be paid to other persons, especially children.
When leaving unattended, secure against unintentional movement.
The machine shall only be operated by instructed and authorized persons.
When leaving unattended, switch off or lock the main power switch to prevent unauthorized use.
Do not handle the plug or machine with wet hands.
Do not unplug machine by pulling on cord. To unplug, grasp the plug, not the cord.
Do not use with damaged cord or plug. Follow all instructions in this manual concerning grounding the machine.
Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners.
Do not pull/run machine over cord. Keep cord away from heated surfaces.
Connect to a properly grounded outlet. See Grounding Instructions.
SAVE THESE INSTRUCTIONS
CHEYENNE 86038850 03/08/07 2-1
HAZARD INTENSITY LEVEL
The following symbols are used throughout this guide as indicated in their descriptions:
HAZARD INTENSITY LEVEL
There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR
SAFETY. The level of hazard intensity is determined by the following definitions:
!
WARNING
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
!
CAUTION
CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage.
FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.
Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel.
FOR SAFETY:
DO NOT OPERATE MACHINE:
Unless Trained and Authorized.
Unless Operation Guide is Read and understood.
In Flammable or Explosive areas.
In areas with possible falling objects.
WHEN SERVICING MACHINE:
Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine. Use manufacturer approved replacement parts.
2-2 CHEYENNE 86038850 03/08/07
GROUNDING INSTRUCTIONS
THIS PRODUCT IS FOR COMMERCIAL USE
ONLY.
ELECTRICAL:
In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine.
Using voltages above or below those indicated on the data label will cause serious damage to the motors.
EXTENSION CORDS:
If an extension cord is used, the wire size must be at least one size larger than the power cord on the machine, and must be limited to 50 feet
(15.5m) in length.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks like the plug in “Fig. A”. A temporary adaptor that looks like the adaptor in “Fig . C” may be used to connect this plug to a 2-pole receptacle as shown in “Fig. B”, if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet
(Fig. A) can be installed by a qualified electrician. The green colored rigid ear, lug, or wire extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw.
CHEYENNE 86038850 03/08/07
Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified
electrician.
2-3
TECHNICAL SPECIFICATIONS
ITEM DIMENSION/CAPACITY
Electrical 115V 60Hz
Electric Vacuum Motor DUAL 2 STAGE (C2, C2H)
DUAL 3 STAGE (C3, C3HP, CHPH)
Solution Pump
Solution Capacity
Recovery Capacity
100PSI (C2, C3, C2H)
200PSI (C3HP, CHPH)
16 gal. (60.6L)
16 gal. (60.6L)
Dimensions – Weight (Empty)
Dimensions - Length
Dimensions - Height
Dimensions - Width
Power Cable
98 lbs. (44.5kgs)
29 in. (73.6cm)
36 in. (91.4cm)
21 in. (53.3cm)
25 ft. (7.6m)
3-1
10/29/01
CHEYENNE 86038850 03/08/07
Vacuum Inlet
Solution Outlet
Solution Tank
Heat Models
ONLY
Mounted next to valve control on manifold plate, located to rear of machine.
Solution and Vacuum
Tank Lid
CONTROLS
Water Pump
Vacuum
Cheyenne HP
ONLY
Vacuum #2
Water Pump
Vacuum #1
Vacuum Tank
Heater
(Optional Accessory)
Optional Equipment:
86000600 – PRV NO. 89226 Deluxe Professional Wand
86260790 – PRV NO. 39604 Hose Asm, 2” Vac/Sol 25ft
CHEYENNE 86038850 03/08/07
Base Assembly
3-2
MACHINE OPERATIONS
PRE-RUN INSPECTION
1. Check all fittings and connectors for proper assembly.
2. Check all hoses for leaks. Repair or replace any damaged hoses.
3. Check power cord(s) for any damage. If damaged, replace.
EQUIPMENT SET-UP
1. Plug power cord from machine into properly grounded wall outlet.
2. Turn vacuum motor switch on and off to make sure there is electrical power at machine.
3. Connect vac hose to machine. Slide the swivel cuff over the outlet on the tank.
4. Connect the hose to your machine and wand. Pull back the knurled collar on the quick
disconnect coupler and push onto the connection
on the chassis. To avoid leaks, check to be that
a positive connection was made.
5. Pour clean, hot water into the solution tank.
To avoid possible tank distortion, water
temperature must not exceed 140 F (60C).
6. Add a non-foaming cleaning solution concentrate, for use in hot water extractors at the proportions noted on the container (See list below), into solution tank.
7. Turn pump and vacuum switch(s) to the on position.
8. Start cleaning.
! WARNING
To prevent possible disease hazard, before attempting to clean bodily fluids spills, you must kill any viruses, germs or bacteria present in the bodily fluid.
SUITABLE INCOMPATIBLE
CHEMICALS CHEMICALS
Clorox II Bleach*
Detergents Carbon
Hydroxides Clorox*
Oxygen Bleaches Chlorinated Bleaches
Sta-Puf Fabric
Aromatic Hydrocarbons
D-Limonene
CLEANING & EMPTYING TANKS
!
WARNING
Always use defoamer if foaming occurs. Foam will suspend large particles which may damage vacuum as well as allow liquid into the vacuum
motor without activating the float shutoff.
1. Before proceeding, make certain that the nozzle is functioning properly. a. To check, hold the wand about one foot above the surface to be cleaned and open the wand valve. A full spray should be observed from the nozzle. b. If the nozzle is not showing a full spray pattern, adjust nozzle for proper pattern, clean, or replace nozzle.
2. Normally, chemical is applied on the push stroke while vacuuming is done on the pull stroke. For heavily soiled carpets the hand tool may be used in the scrubbing manner, applying chemical in both the push and pull stroke.
A LWAYS FINISH UP AN AREA WITH A VACUUM PULL
STROKE .
3. When cleaning, keep the working opening
(wand mouth) flat on the surface being cleaned.
Keep the wand moving when the valve is open.
4. The shutoff float inside the recovery tank will impede the vacuum flow when the tank is full.
When this occurs, empty the recovery tank. Do this by opening the dump valve located at the back of the machine. NOTE: Dispose of waste in a proper manner which would not violate any
Local, State or Federal law.
5. Once the recovery tank has been emptied, you may once again proceed with cleaning
!
CAUTION
Operating Vacuum after shutoff has activated could draw water directly into the vac motor. This will cause damage to the motor, therefore voiding your warranty.
!
CAUTION
A LWAYS TEST CARPET FOR COLOR FASTNESS IN AN
INCONSPICUOUS PLACE . Also, to avoid prolonged drying times, do not spray too much solution in any one area.
!
WARNING
Perchlorethylene (perc)
Phenols
Trichlorethylene
*Registered Trademark
3-3 CHEYENNE 86038850 03/08/07
Before making any adjustments or performing any maintenance to your machine, disconnect
the power cord from the electrical source.
SHUT DOWN AND STORAGE
1. Turn Switch OFF. Empty recovery tank completely and rinse several times to remove any dirt or debris that may be left behind.
2. Drain any unused cleaning solution from solution tank and rinse with clean water to remove any suds left behind by the cleaning chemicals.
NOTE: Dispose of waste in a proper manner which would not violate any Local, State or
Federal law
3. Run a small amount of clean water through pump if chemicals were used. This will help insure the life of your pump.
4. Check the spray jet on the cleaning tool for full spray pattern and inspect vac head for any obstructions.
5. Remove as much moisture from system before storing in cold climates. Excess water may freeze during storage and crack internal components, causing damage to the unit.
MACHINE OPERATIONS
CHEYENNE 86038850 03/08/07 3-4
MAINTENANCE
DAILY MAINTENANCE
Unplug power cord(s) before servicing or making any repairs.
1. Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water.
2. Vacuum out the solution tank.
3. Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a
1-10 bleach to water solution. Wastewater should be disposed of properly.
4. Occasionally check filter screen at the bottom of the solution tank and rinse clean with hot water if necessary.
5. Inspect hoses for wear. Frayed or cracked hoses should be replaced to avoid vacuum or solution pressure loss.
6. Inspect power cord for wear or damage. This cable will lie on wet carpet. To prevent electrical shock replace cords that are frayed or have cracked insulation immediately.
7. Clean all dirt and obstructions from drain valve and gaskets to prevent possible leakage and premature wear.
8. Run clean water through solution pump when work is complete.
9. Empty both tanks and rinse, run vacuum (s) for at least one minute to dry motor(s).
10. Store with access covers removed to allow tanks to dry.
PERIODIC MAINTENANCE
1. Twice a month, flush a white vinegar solution
(one quart vinegar to two gallons water) or antibrowning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system.
2. If spray jet becomes clogged, remove the spray tip, wash it thoroughly, and blow dry. NOTE: D O
NOT USE PINS , WIRE , ETC . TO CLEAN NOZZLE AS
THIS COULD DESTROY THE SPRAY PATTERN .
3. Apply silicone lubricant to solution nipple.
4. Periodically inspect all hoses, electrical cable and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation on the power cord is broken or frayed, repair or replace immediately. Don’t take chances with electrical fire or shock.
5. Clean outside of all tanks and check for damage.
4-1
CHEYENNE 86038850 03/08/07
MONTHLY MAINTENANCE
1. Check all bearings for noise and wear.
2. Check all gaskets for wear and leakage.
3. Check pump pressure; observe spray pattern and check gauge if necessary.
4. Check overall performance of machine.
SEMI-ANNUALLY
1. Check vacuum motor brushes.
LUBRICATION
For hose fitting lubrication, use a light silicone lubricant which will not damage o-rings.
STORAGE
Thoroughly clean machine if it is to be stored.
Protect this machine from freezing while in storage.
MAINTENANCE
Only qualified maintenance personnel are to perform the following repairs.
SOLUTION PUMP REPLACEMENT
1. Turn off all switches and unplug the machine.
2. Tip recovery tank to gain access to solution tank.
3. Remove solution hoses from fittings on pump.
Disconnect wires.
4. Remove the screws that fasten the pump to the frame.
5. Reverse process to install new replacement pump.
VACUUM MOTOR REPLACEMENT
1. Turn off all switches and unplug machine.
2. Tip recovery tank to expose vacuum (s).
3. Locate the proper vacuum motor wires and disconnect.
4. Unfasten screws holding vacuum to vac plate.
Remove the vacuum motor.
5. Reverse process to install vacuum motor replacement.
Vacuum Motor Carbon Brushes Replacement (Windsor)
End Cap
Carbon
Brushes
WARNING: The green ground wire must be attached for safe operation.
See wiring diagram.
Vacuum Motor Carbon Brushes Replacement (Ametek)
End Cap
Carbon
Brushes
WARNING: The green ground wire must be attached for safe operation.
See wiring diagram.
Note: When replacing carbon brushes loosen wire terminal
BEFORE removing screws on bracket.
Wire
Terminal
Note:
Place stop in groove.
If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.
Wire Terminal
If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.
Important:
These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.
Important:
These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.
3/8 (9.5mm)
Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.
3
8
[9.5mm]
Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.
CHEYENNE 86038850 03/08/07 4-2
MAINTENANCE
PUMP REPLACEMENT PARTS FOR SHURFLO 100 PSI (250-64A)
86161980 – PRV NO. 250-67
Switch Asm
Pump Head Replacement
86251040
PRV NO. 65187
Bypass Valve Asm
86258830
PRV NO. 84161
Diaphragm
86235100
PRV NO. 29206
PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI 86251110 – PRV NO. (65219)
DIAPHRAGM
86235120
PRV NO. 29219
86258860
PRV NO. 84166
86251090
PRV NO. 65204
PUMP HEAD
VALVE ASM
PUMP REPLACEMENT KITS
200 PSI PUMPTEC
CAM & BEARING KIT
86201170
PRV NO. 250-79G
86247360
PRV NO. 53245
MOTOR
VALVE & O-RINGS KIT
86201160
PRV NO. 250-79F
PLUNGER & SEALS KIT
86201150
PRV NO. 250-79E
4-3 CHEYENNE 86038850 03/08/07
MAINTENANCE
PRESSURE REGULATOR
For best results with the pressure regulator, we recommend that you clean and lubricate the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive.
1. Turn unit off before lubricating.
2. Remove cap, spring and spring retainer plate.
3. With fingertips remove piston and u-cup.
4. Wipe piston and u-cup clean of any film or scale.
5. Lubricate the piston and u-cup with Superlube.
7. With pump ON, re-adjust pressure regulator for normal operation.
LUBRICATE U-CUP WITH SUPERLUBE MONTHLY.
U-CUP
SPRING RETAINER PLATE
OUT
IN PISTON
SPRING
(GOLD - 125 PSI)
(GREEN - 200 PSI)
CAP
CHEYENNE 86038850 03/08/07 4-4
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Loss of Power
Dead electrical circuit
Faulty power cord
Check building circuit breaker or fuse box.
Replace
Equipment not grounding Follow grounding instructions exactly
Electrical shock
Vac motor speed varies or doesn’t run
Receptacle not grounded Contact an electrician to check building’s wiring
Internal wiring problem
Have a trained service technician check machine’s wiring
Worn motor brushes
Motor worn out
Faulty switch
Loose vacuum dome
Replace
Replace
Replace
Center and seal dome over tank
Loss of vacuum
Crack in dome of poor joint Replace or repair using acrylic plastic cement only
Lint or dirt clogging
With power off clean screen vacuum screen
Loose cuffs on vacuum hose
Vac motor seals leaking
Tighten cuffs turning counterclockwise
Replace
Floor tool vac chamber clogged
Vac motor, hose, or dome gasket
Wash out with hose. Pick lint out with a wire
Replace
Pump inlet screen plugged Clean inlet screen
Press trigger to open valve on cleaning wand to
Pump air locked relieve air
Pump runs no solution
Pump runs, loss of pressure
Pump will not run
Solution hose fitting hard to connect
Carpet not getting clean
Carpet too wet
Carpet browning
Solution not flowing properly
Internal or external solution line damaged and leaking
Internal pump components wearing out
Check BPR for particles or cuts in seals
Unit not plugged in
Loose wiring
Corrosion on fittings.
Severe soil conditions
Replace
Replace, see pump kit components (Pg 4-3)
Take piston from BPR and lubricate with Superlube.
If problem still exists change BPR.
Connect unit to 3 prong grounded outlet
See dealer
Clean with steel wool. Soak in acetic acid (white vinegar). Lubricate lightly with silicone base lubricant.
Make several passes at right angles to each other.
Use a pre-spray.
Over saturation
Leaving carpet too wet
Too much chemical
Light carpet with no brown prevention
Check solution wand. Make several passes without spray
Check for loss of vac pressure
Check label for correct solution concentration
Go over carpet with browning prevent only
Solution hose connection Check for positive connection
Faulty pump Repair or replace
Faulty floor tool valve
Faulty pump switch
Repair or replace
Repair
4-5 CHEYENNE 86038850 03/08/07
THIS PAGE LEFT BLANK INTENTIONALLY
CHEYENNE 86038850 03/08/07 4-6
BASE GROUP PARTS
9
7
5
6
8
8
6
7
1
6
4
5
3
2
5-1 CHEYENNE 86038850 03/08/07
BASE PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86010710 87080
2 86103460 57196
3 86202250 040-06
4 86010760 87142
5 86279130 87083
6 86006760 70305
7 86199430 040-03
8 86270830 57023
2
2
2
2
6
4
2
2
WASHER, .5 X 1.25 FLAT GR8 PLT
NUT, 1/2 PUSH-ON DOME CAP
WHEEL 8” BLK CENTERED HUB
WASHER, .344 X .69 X .066 FLAT PLT
WASHER, 5/16 SPLIT LOCK PLTD
SCR, 5/16-18 X 3/4 HHCS
CASTER SWIVEL 4”
NUT, 5/16-18 HEX NYLOCK SS
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07 5-2
SOLUTION TANK GROUP
17
16
15
14
13
18
19
12
11
10
9
1
2
3
4
5
6
7
5-3 CHEYENNE 86038850 03/08/07
SOLUTION TANK PARTS LIST
REF PART NO. PRV NO.
2 86005720 57106 2 NUT, 8-32 W/ STAR WASHER PLTD
3 86042400 56-502126 1 NIPPLE ASSEMBLY, QD MOUNT
4 86197370 31017
5 86161650 39598
1
1
ELBOW, 1/4 FPT X 1/4 FPT
HOSE, HP 42. 1/4MPT X 1/4MPT
9 86192840 290-08
10 86197940 40027
11 86197940 70744
12 86199970 120-08
13 86279610 87190
14 86005810 57245
15 86005580 56012
16 86020650 70051
QTY DESCRIPTION
1
1
4
1
4
4
1
2
STRAINER, 1/4 NPT 50 MESH
HOSEBARB, 3/8MPT X 1/2 90D DL
SCR, 1/4-20 X 1 PFH BLK SS
HANDLE, MACHINE BLACK
WASHER, SEAL 5/8 OD NEOPRENE
NUT, 1/4-20 HEX NYLOCK SS
NIPPLE, 1/4 FPT QD
SCR, 8-32 X 1/2 PPHMS NP
17 86161800 46-802531 1 LATCH, CONCEALED KEEPER
18 86161960 70222 3 SCR, #8 X 1/2 PPHST BLK
19 86279190 87095 3 WASHER, #10 FLAT PLTD
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-4
PUMP GROUP
100 PSI NO HEAT
2 ST VAC
20
13
24A
24B
17
17
18
12
2 1
2 2
2 3
1 1
1 0
9
13
16
8
1
2
3
4
5
6
7
3
TO SOLUTION
TANK UPPER SPIN
FITTING (86197630,
PRV NO. 40042)
15
14
13
TO SOLUTION
TANK (86197550,
PRV NO. 40014)
5-5
CHEYENNE 86038850 03/08/07
PUMP PARTS LIST
100 PSI NO HEAT
2 ST VAC
2
3
4
5
6
7
8
11
12
13
14
15
16
17
18
20
21
86272730
86002750
86000950
86199540
86256240
86199310
86005670
86005700
86164130
86222770
86280970
86270990
86278980
86001550
86276240
86280800
86197560
66017
70088
70532
060-04A
73505
110-14
57040
57104
82859
20042
39233
57090
87014
40043
70614
39031
40015
2
1
2
1
1 STRAIN RELIEF, 1/2 NPT TRUMPET
1 CAP PLUG 7/8”
1
2
1
6
1
2
2
2
2
1
1
PLUG, 1/4 BASS PIPE
SCR, 10-32 X 1/2 PPHMS SS
SCR, 10-32 X 1/2 PPHMS BLK
CORD ASM, 14/3 SJT X 25’ BLK
NUT, 1/2 NPT CONDUIT
NUT, 10-32 W/STAR WASHER PLTD
HOSE, 1/2 NYLOBRAID 20”
CLAMP, 3/8 HOSE (D-SLOT)
HOSE 3/8 RUBBER X 17”
NUT, 10-32 NYLOCK SS
WASHER, #8 INT. STAR
HOSEBARB, 3/8MPT X 3/8 90D
SCR, 10-32 X 1 1/8 PPHMS SS
HOSE, 3/8 RUBBER X 24”
HOSEBARB, 1/4FPT X 3/8
23 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T
24A 86201430 250-64A 1 SHURFLO 100 PSI PUMP DEMAND
24B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)
SERIAL NO.
FROM
NOTES:
1000132734
CHEYENNE 86038850 03/08/07 5-6
PUMP GROUP
100 PSI NO HEAT
3 ST VAC
19
12
16
23A
23B
16
11
20
10
9
21
12
17
15
22
8
1
7
2
3
5
4
TO SOLUTION TANK
UPPER SPIN FITTING
(86197630, PRV NO. 40042)
4
6
14
13
12
TO SOLUTION TANK
(86197550, PRV NO.
40014)
5-7 CHEYENNE 86038850 03/08/07
PUMP PARTS LIST
100 PSI NO HEAT
3 ST VAC
2
3
4
5
6
7
10
11
12
13
14
15
16
17
19
20
86272730
86002750
86006950
86199540
86256240
86005670
86005700
86282720
86222770
86280970
86270990
86278980
86001550
86276240
86280800
86197560
66017
70088
70532
060-04A
73505
57040
57104
82859
20042
39233
57090
87014
40043
70614
39031
40015
2
1
4
2
2
2
2
1
6
1
2
2
2
2
1
1
PLUG, 1/4 BASS PIPE
SCR, 10-32 X 1/2 PPHMS SS
SCR, 10-32 X 1/2 PPHMS BLK
CORD ASM, 14/3 SJT X 25’ BLK
STRAIN RELIEF, 1/2 NPT TRUMPET
NUT, 1/2 NPT CONDUIT
NUT, 10-32 W/STAR WASHER PLTD
HOSE, 1/2 NYLOBRAID 20”
CLAMP, 3/8 HOSE (D-SLOT)
HOSE 3/8 RUBBER X 17”
NUT, 10-32 NYLOCK SS
WASHER, #8 INT. STAR
HOSEBARB, 3/8MPT X 3/8 90D
SCR, 10-32 X 1 1/8 PPHMS SS
HOSE, 3/8 RUBBER X 24”
HOSEBARB, 1/4FPT X 3/8
22 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T
23A 86201430 250-64A 1 SHURFLO 100 PSI PUMP DEMAND
23B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)
SERIAL NO.
FROM
NOTES:
1000132734
CHEYENNE 86038850 03/08/07 5-8
PUMP GROUP
100 PSI WITH HEAT
2 ST VAC
22
21
14
18
25A
25B
18
19
17
13
12
11
14
23
10
9
1
2
3
5
4
8
7
5
6
TO SOLUTION
TANK UPPER SPIN
FITTING (86197630 -
PRV NO. 40042)
16
15
14
TO SOLUTION
TANK (86197550 -
PRV NO. 40014)
5-9 CHEYENNE 86038850 03/08/07
PUMP PARTS LIST
100 PSI WITH HEAT
2 ST VAC
2
3
5
6 86199540 060-04A 1 CORD ASM, 14/3 SJT X 25’ BLK
7 86256240 73505
8
9
12
13
14
15
16
17
18
19
21
22
86005590
86005580
86006950
86199310
86005670
86005700
86164130
86222770
86280970
86270990
86278980
86001550
86276240
86280800
86157620
56014
56012
70532
110-14
57040
57104
82859
20042
39233
57090
87014
40043
70614
39031
40015
2
2
4
1
1
1
2
1
6
1
2
2
2
2
1
1
NIPPLE, 1/4 CLOSE
NIPPLE, 1/4 FPT QD
SCR, 10-32 X 1/2 PPHMS BLK
STRAIN RELIEF, 1/2 NPT TRUMPET
CAP PLUG 7/8”
NUT, 1/2 NPT CONDUIT
NUT, 10-32 W/STAR WASHER PLTD
HOSE, 1/2 NYLOBRAID 20”
CLAMP, 3/8 HOSE (D-SLOT)
HOSE 3/8 RUBBER X 17”
NUT, 10-32 NYLOCK SS
WASHER, #8 INT. STAR
HOSEBARB, 3/8MPT X 3/8 90D
SCR, 10-32 X 1 1/8 PPHMS SS
HOSE, 3/8 RUBBER X 24”
HOSEBARB, 1/4FPT X 3/8
24 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T
25A 86201430 250-64A 1 SHURFLO 100PSI PUMP DEMAND
25B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)
SERIAL NO.
FROM
NOTES:
1000132734
CHEYENNE 86038850 03/08/07
5-10
PUMP GROUP
200 PSI NO HEAT
3 ST VAC
ITEM 10
20
23
1
2
25
4
3
5
24
12
13
11
14
SOLUTION
TANK
28
18
17
13
9
15
22
21
8
4
16
(TO SOLUTION TANK STRAINER)
7
6
18
19
5-11
27
CHEYENNE 86038850 03/08/07
PUMP PARTS LIST
200 PSI NO HEAT
3 ST VAC
2
3
4
5
6
8
9
10
11
26
27
28
86272730
86006590
86006950
86199540
86256240
86197370
86005670
86286040
86005700
86279530
86270990
86162070
66017
70088
70532
060-04A
73505
31017
57040
84182
57104
87173
57090
84198
2
1
2
2
2
1
2
1
2
ELBOW, 1/4FPT X 1/4FPT
NUT, 1/2 NPT CONDUIT
VALVE BPR 200 PSI
NUT, 10-32 W/STAR WASHER PLTD
13 86233150 20042
14 86282720 82859
15 86161640 39597
16 86280810 39032
4 CLAMP, 3/8 HOSE (D-SLOT)
1 HOSE, 1/2 NYLOBRAID X 20”
1 HOSE, HP 15.0 1/4MPT X 1/4MPT
1 HOSE, 3/8 RUBBER X 15”
17 86197220 40014
18 86199640 030-16
1 HOSEBARB, 1/4 MPT X 3/8 DL
2 ELBOW, 1/4 NPT STREET LONG 90D
19 86200150 151-38D 1 HOSE, PULSE 27.0 1/4 MPTX1/4MPT
20 86272730 66017 1 PLUG, 1/4 BRASS PIPE
21 86010650 87018
22 86276240 70614
23 86201130 250-79
24 86197350 22014
2 WASHER, #10 X 9/16 OD
2 SCR, 10-32 X 1 1/8 PPHMS SS
1 PUMPTEC 200PSI PUMP & MOTOR
1 COUPLER, 1/4F HEX
1
2
1
PLUG, 1/4 BRASS PIPE
SCR, 10-32 X 1/2 PPHMS SS
SCR, 10-32 X 1/2 PPHMS BLK NP
CORD ASM, 14/3 SJT X 25’ BLK
STRAIN RELIEF, 1/2 NPT TRUMPET
WASHER, .765ID X 1.31OD X .09T SS
NUT, 10-32 HEX NYLOCK SS
VALVE, BPR 200 PSI BRASS
SERIAL NO.
FROM
NOTES:
INCLUDES
62967
CHEYENNE 86038850 03/08/07 5-12
PUMP GROUP
200 PSI WITH HEAT
7.2 3 ST VAC
ITEM 11
22
1
2
3 4
28
27
5
6
8
26
29
25
10
8
9
13 12
14
30
SOLUTION
TANK
15 17
18
24
23
16
14
19
(TO SOLUTION TANK STRAINER)
7
17
21
5-13
20
CHEYENNE 86038850 03/08/07
PUMP PARTS LIST
200 PSI WITH HEAT
7.2 3 ST VAC
REF PART NO.
2
3
4
5
6
8
9
10
11
28
29
30
86005590
86005580
86161770
86199310
86199530
86006950
86197370
86005670
86286040
86279530
86256240
86162070
PRV NO. QTY DESCRIPTION
56014
56012
500452
110-14
060-04
70532
31017
57040
84182
87173
73505
84198
2
2
1
1
1
4
1
1
1
13 86005700 57104
14 86233150 20042
15 86222770 82859
16 86161640 39597
2
4
1
1
NUT, 10-32 W/STAR WASHER PLTD
CLAMP, 3/8 HOSE (D-SLOT)
HOSE, 1/2 NYLOBRAID X 20”
HOSE, HP 15.0 1/4MPT X 1/4MPT
17 86199640 030-16 2
ELBOW, 1/4 NPT STREET LONG
90D
18 86156850 40014
19 86280810 39032
1 HOSEBARB, 1/4MPT X 3/8 DL
1 HOSE, 3/8 RUBBER X 15”
20 86270990 57090 2 NUT, 10-32 HEX NYLOCK SS
21 86200150 151-38D 1
HOSE, PULSE 27.0 1/4MPT X
1/4MPT
22 86272730 66017
23 86010650 87018
24 86276240 70614
25 86201130 250-79
26 86197350 22014
1 PLUG, 1/4 BRASS PIPE
2 WASHER, #10 X 9/16 OD
2 SCR, 10-32 X 1 1/8 PPHMS SS
1 PUMPTEC 200PSI PUMP & MOTOR
1 COUPLER, 1/4F HEX
1
1
1
NIPPLE, 1/4 CLOSE
NIPPLE, 1/4 FPT QD
LABEL HEATER
CAP PLUG 7/8”
CORD ASM, 12/ SJT X 25’ BLK
SCR, 10-32 X 1/2 PPHMS BLK NP
ELBOW, 1/4FPT X 1/4FPT
NUT, 1/2 NPT CONDUIT
VALVE, BPR 200 PSI
WASHER, .765ID X 1.31OD X .09T
STRAIN RELIEF, 1/2 NPT TRUMPET
VALVE, BPR 200 PSI BRASS
SERIAL NO.
FROM
NOTES:
INCLUDES 62967
CHEYENNE 86038850 03/08/07 5-14
RECOVERY TANK-2 STAGE GROUP
10
13
11
12
2
1
11
3
4
9
8
5
7
6
5-15 CHEYENNE 86038850 03/08/07
RECOVERY TANK-2 STAGE PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86161910 48-941382 1 PLATE, SWITCH MODEL 2
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86043410 56-502173 1 ASSY, EXH DCT FLNG PRT405
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256
8 86033320 78474
1
1
GASKET, DUMP VALVE
VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK
10 86161820 56-502156 1 LID, VACUUM TANK
11 86161960 70222
12 86199840 090-12A
6
1
SCR, #8 X 1/2 PPHST BLK
FLOAT CAGE ASSY COMPLETE
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07 5-16
RECOVERY TANK-3 STAGE GROUP
10
13
11
12
2
1
11
3
4
9
8
5
7
6
5-17 CHEYENNE 86038850 03/08/07
RECOVERY TANK-3 STAGE PARTS LIST
REF PART NO. PART NO. QTY DESCRIPTION
1 86161920 48-941383 1 PLATE, SWITCH MODEL 2
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86042360 56-502143 1 BRKT, CORD WRAP NO HEATER
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256
8 86033320 78474
1
1
GASKET, DUMP VALVE
VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK
10 86161820 56-502156 1 LID, VACUUM TANK
11 86161960 70222
12 86199840 090-12A
6
1
SCR, #8 X 1/2 PPHST BLK
FLOAT CAGE ASSY COMPLETE
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07 5-18
RECOVERY TANK- 2 STAGE WITH HEAT GROUP
10
13
11
12
2 1
11
3
4
9
8
5
7
6
5-19 CHEYENNE 86038850 03/08/07
RECOVERY TANK-2 STAGE-WITH HEAT PARTS LIST
REF PART NO. PART NO. QTY DESCRIPTION
1 86161910 48-941382 1 PLATE, SWITCH MODEL 2
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86042340 50-501882 1 BRKT, HEATER MOUNT
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256
8 86033320 78474
1
1
GASKET, DUMP VALVE
VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK
10 86161820 56-502156 1 LID, VACUUM TANK
11 86161960 70222
12 86199840 090-12A
6
1
SCR, #8 X 1/2 PPHST BLK
FLOAT CAGE ASSY COMPLETE
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07 5-20
RECOVERY TANK- 3 STAGE WITH HEAT GROUP
10
13
11
12
2 1
11
3
4
9
8
5
7
6
5-21 CHEYENNE 86038850 03/08/07
RECOVERY TANK-3 STAGE-WITH HEAT PARTS LIST
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86042340 50-501882 1 BRKT, HEATER MOUNT
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256 1 GASKET, DUMP VALVE
8 86033320 78474 1 VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK
10 86161820 56-502156 1 LID, VACUUM TANK
11 86161960 70222 6 SCR, #8 X 1/2 PPHST BLK
12 86199840 090-12A 1 FLOAT CAGE ASSY COMPLETE
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07 5-22
VACUUM GROUP (2 STAGE)
5-23
8
9
6
3
12
2
6
11
7
4
1
2
3
10
4
6
5
CHEYENNE 86038850 03/08/07
VACUUM GROUP-2 STAGE PARTS LIST
REF PART NO.
1
2
3
4
-
-
86005810
86003760
86201970
86202040
86202070
86135320
PRV NO.
57245
35166
065-92
360-04A
360-04B
140687
QTY DESCRIPTION
SERIAL NO.
FROM
NOTES:
3 NUT, 1/4-20 HEX NYLOCK SS
2 GASKET, VAC MTR
6
2
VAC SPACER 2 1/4 II STAGE
VAC MOTOR, 120V 5.7 2ST TD
- BRUSHES, VAC FOR 116392-00 SERVICE ONLY
- BRUSH SET, 120V VAC WINDSOR 1000121568 SERVICE ONLY
5 86007010 70663
6 86010630 87013
3 SCR, 1/4-20 X 3 1/4 HHCS PLT
9 WASHER, 1/4 ID X 5/8 OD SS
7 86005710 57105 3 NUT, 1/4-20 HEX W/ STAR WASHER
8 86042350 56-502084 1 BRKT, VAC MOUNT, DUAL 2 STG
9 86161520 43-807517 1 GASKET, VAC MTG.
10 86027140 75377 1 TANK, RECOVERY, CHEYENNE
11 86256480 70813
12 86273750 70011
3
3
STUD, 1/4-20 X 3.5 SS
SCR, 1/4-20 X 5/8 HHCS SS
CHEYENNE 86038850 03/08/07 5-24
VACUUM GROUP – 3 STAGE
5-25
8
9
6
11
2
7
12
6
3
4
10
1
2
3
4
6
5
CHEYENNE 86038850 03/08/07
VACUUM GROUP-3 STAGE PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86005810
2 86003760
57245
35166
3 86201950 065-24E
4 86124130 53130
- 86135320
- 86135300
140687
140676
3 NUT, 1/4-20 HEX NYLOCK SS
2 GASKET, VAC MTR
6 VAC SPACER 3 1/8
2 VAC MOTOR, 120V 5.7 3ST W/O TB
- BRUSH SET, 120V VAC WINDSOR
- BRUSH SET, 120V 3ST VAC AMETEK
5 86216610
6 86010630
70062
87013
3 SCR, 1/4-20 X 4 HHCS GR5 PLTD
9 WASHER, 1/4 ID X 5/8 OD SS
7 86005710 57105 3 NUT, 1/4-20 HEX W/ STAR WASHER
8 86042320 56-502091 1
BRACKET, VACUUM MOUNT, 3
STAGE
9 86161520 43-807517
10 86027140 75377
11 86256490
12 86273750
70814
70011
1 GASKET, VAC MTG.
1 TANK, RECOVERY, CHEYENNE
3 STUD, 1/4-20 X 4.5 SS
3 SCR, 1/4-20 X 5/8 HHCS SS
SERIAL NO.
FROM
NOTES:
*
* SERVICE
ONLY
SERVICE
ONLY
CHEYENNE 86038850 03/08/07 5-26
VACUUM GROUP
SINGLE 7.2 3-STAGE
9
3
8
7
6
1
2
10
3
4
5
5-27 CHEYENNE 86038850 03/08/07
VACUUM GROUP-3 STAGE (7.2) PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86005810 57245
2 86201940 065-24C
3 86010630 87013
4 86020710 70062
3 NUT, 1/4-20 HEX NYLOCK SS
3 VAC SPACER 2 1/2
18 WASHER, 1/4 ID X 5/8 OD SS
3 SCR, 1/4-20 X 4 HHCS GR5 PLTD
5 86202050 360-05A
6 86003760 35166
1 VAC, 117507-13 110V 3 ST 7.2
1 GASKET, VAC MTR
7 86042330 56-502092 1 BRACKET, VACUUM MOUNTING 7.2
8 86273750 70011 6 SCR, 1/4-20 X 5/8 HHCS SS
9 86161520 43-807517 1 GASKET, VAC MTG.
10 86027140 75377 1 TANK, RECOVERY CHEYENNE
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07 5-28
HEATER GROUP
23
24
22
26
25
21
20
18
16
19
4
23
24
22
4
1 19
21
20
4
5
14
15
4
4
17
2
3
29
6
28
5-29
I
O
11
9
27
29
13
28
12
8
7
10
CHEYENNE 86038850 05/02/09
REF
21
22
23
24
17
18
19
20
25
26
27
28
29
13
14
15
16
9
10
11
12
5
6
7
8
1
2
3
4
HEATER GROUP Parts List
PART NO. PART NO. QTY DESCRIPTION
86161750 48-941396 LABEL, HEATER WARNING PROCHEM
86241010 41504 HOUSING, CAP OUTLET END NU
86245650 50776 LABEL, FOR SAFETY
86006790 70351 SCR, 10-32 X 3/8 HHTR W/STAR
86005700 57104 NUT, 10-32 W/STAR WASHER PLTD
86241470 41513 INSULATION, HEATER
86201790 130-14C 1 THERMOSTAT RESET 302
86201800 130-14 HEATER ELEMENT 110V
86162010 32-900195 SWITCH, DPST, LGHTD RCKR GRN
86246490 51041 LIGHT, 115V NEON INDICATOR
86171080 41503 HOUSING, CAP SWITCH END NU
86233480 22046 CLIP, NEON LAMP
86006180 66095 PLUG, 1/8 MPT HEX BRASS
86201810 130-14I THERMOSTAT W/SPADE LEADS
86264110 41514 INSULATION PAPER
86268800 88623 WIRE, 4” G/Y/14 76010 X 76010
86092890 41502 HOUSING ASM, HEATER PORT NU
86005670 57040 NUT, ½ NPT CONDUIT
86175890 11-800039 BUSH, ¼ x 1/8 BR
86180360 12-800040 ELL, 1/8P X 1/4T BR
86008920 80889 BOOT, RUBBER TERM. ISOLATOR
86183990 10-805393 HOS, 3/16 X 14-1/4(1/4FT) BS
86180340 12-800031 ELL, 1/4P X 1/4T BR
86002450 22015 COUPLER, ¼ QD
86256240 73505 STRAIN RELIEF, ½ NPT TRUMPET
86199530 060-04 CORD ASM, 12/ SJT X 25’ BLK
86326680 - HEATER CART, CASE WELDED
86200870 300-06A PAN HD SH MTL SCREW 6 X 3/16 B
86010650 87018 WASHER, #10 X 9/16 OD
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 06/09/09 5-30
TANK & LID PARTS
2
1
3
4
7
(86161800, PRV
NO. 46-802531)
Keeper)
6
3
5
5-31
CHEYENNE 86038850 03/08/07
TANK & LID PARTS LIST
REF PART NO. PART NO. QTY DESCRIPTION
2 86161960 70222
3 86006950 70532
4 SCR, #8 X 1/2 PPHST BLK
12 SCR, 10-32 X 1/2 PPHMS BLK NP
4 86161570 46-802530 2 HINGE, SOUTHCO C6-34
5 86161590 46-802540 2 HINGE, SOL. VAC TANK
6 86005720 57106
7 86020650 70051
2 NUT, 8-32 W/ STAR WASHER PLTD
2 SCR, 8-32 X 1/2 PPHMS NP
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07 5-32
LABEL & STRAP GROUP
3
1AB
2
5-33
CHEYENNE 86038850 03/08/07
REF
PART
NO.
PRV
NO.
QTY DESCRIPTION
500531 2
LABEL, PROCHEM
LOGO 6 X 1.75
500567 1
LABEL, CHEYENNE
MAIN
LABEL & STRAP PARTS LIST
SERIAL
NO.
NOTES:
10075210, PRV NO. C3, AND
10075220, C3HP ONLY
CHEYENNE 86038850 03/08/07 5-34
WIRE GROUP
100 PSI
2ST VAC
5-35 CHEYENNE 86038850 03/08/07
WIRE GROUP
100 PSI
3 ST VAC
CHEYENNE 86038850 03/08/07 5-36
WIRE GROUP
200 PSI
3 ST VAC
5-37
CHEYENNE 86038850 03/08/07
WIRE GROUP
200 PSI
7.2 3 ST VAC
CHEYENNE 86038850 03/08/07 5-38
WIRE GROUP - HEATER
INSULATION 86282790
PRV NO. 730129
WHITE WIRE 5"
BLACK WIRE 5"
GREEN WIRE 5"
86266250
PRV NO. 76064L
ON HTR
CORE
86266030
PRV NO. 76031
86266250
PRV NO. 76064L
5"
1
2
POWER SWITCH
4
5
86268800
PRV NO. 88623
86267560
PRV NO. 880300
THERMAL
SWITCH
ON HTR
CANISTER (130-14 I)
(130-14C)
86266030
SAFETY
SWITCH
86267560
86282800
PRV NO. 880300 PRV NO. 730314
4"
PRV NO. 76031
86266250
PRV NO. 76064L
T
E
R
H
E
A
5"
86282790
PRV NO. 730129
LIGHT
M
E
N
T
E
L
E
86282790
PRV NO. 730129
5"
5-39 CHEYENNE 86038850 03/08/07
Advertisement