Report No. : 09-1330-00245
Test item description .................... :
Digital Color Camera
Trade Mark .......................................:
SAMSUNG
Manufacturer ....................................:
Same as applicant (Factory: see page 3)
Model/Type reference.......................:
SCC-B2035P and variants model (See the page 3)
Ratings..............................................:
AC 220-240V~, 50 Hz, 3.3W, Class I
Copy of marking plate
- Label marking
Page 3 of 33
Report No. : 09-1330-00245
Summary of testing:
- Prepared for Class I apparatus.
Summary of compliance with National Differences:
The sample(s) tested complies with the requirements of IEC/EN 60065:2002 amd 1:2006. Compliance
with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC, is recorded at the
end of this report.
Factory
Tianjin Samsung Electronics Co., Ltd.
300457, TSEC12, 4th Avenue, TEDA, Tianjin, China
Item covered
Model no.
Difference
SCC-B2035P
SCC-B2033P
Basic Model
Same as basic model except for CCD and Software
SCC-B2031P
Same as basic model except for CCD and Software
SCC-B1031P
Same as basic model except for CCD and Software
SCC-B2037P
Same as basic model except for CCD and Software
SCC-A2033P
Same as basic model except for CCD and Software
Page 4 of 33
Report No. : 09-1330-00245
Test item particulars.................................................. :
Classification of installation and use............................ : Class I equipment
Supply Connection....................................................... : Appliance inlet
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object................. : N/A
- test object does meet the requirement....................... : Pass (P)
- test object does not meet the requirement................. : Fail (F)
Testing.......................................................................... :
Date of receipt of test item ............................................ : April 16 , 2009
Date (s) of performance of tests ................................... : April 16 , 2009 – May 13, 2009
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
-
Page 5 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
3
GENERAL REQUIREMENTS
Result - Remark
Safety class of the apparatus ................................. : Class I equipment
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
5
MARKING
5.1
Verdict
Pass
No
Pass
Comprehensible and easily discernible
Bottom enclosure
Pass
Permanent durability against water and petroleum
spirit
Yes
Pass
Identification, maker, model ................................... : SAMSUNG, SCC-B2035P
Pass
c)
Class II symbol if applicable
Pass
d), e)
Rated supply voltage and symbol .......................... : AC 220-240V ~
Pass
f)
Frequency if safety dependant
50Hz
Pass
g), h), i)
Rated current or power consumption .................... : 3.3 W
Pass
5.2
Earth terminal
Class I equipment
Pass
b)
Hazardous live terminals
No such terminals
N/A
c)
Supply output terminals (other than mains)
5.3
Use of triangle with exclamation mark
5.4
Instructions for use
Pass
5.4.1
Mains powered equipment not exposed to dripping In user manual
or splashing. Warning concerning objects filled
with liquid, etc.
Pass
b)
Hazardous live terminals, instructions for wiring
No such terminal
N/A
c)
Instructions for replacing lithium battery
No lithium battery
N/A
Instructions for modem if fitted
No modem used
N/A
d)
Class I earth connection warning
Class I equipment
Pass
e)
Instructions for multimedia system connection
In user manual
Pass
f)
Special stability warning for fixed installation
N/A
g)
Warning: battery exposure to heat
N/A
h)
Warning: protective film on CRT face
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
a), b)
Class I
a)
a)
Pass
In circuit diagram
In user manual
Pass
Pass
Page 6 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Instructions for permanently connected equipment
No permanently connected
equipment
N/A
No ionizing radiation
N/A
6
HAZARDOUS RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
6.1
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N/A
Laser radiation, emission limits to IEC 60825-1 .... : No laser system
N/A
Emission limits under fault conditions .................... :
N/A
EN 60065
6.2
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values, (See appended table)
any single protective device defeated except those
of Cl. 7.1 a) and b)
Pass
7.1.1
Temperature rise of accessible parts
(See appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
(See appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as (See appended table)
a mechanical barrier
Pass
7.1.4
Temperature rise of windings
(See appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(See appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150 oC
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
Considered as bare
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
No such devices
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
No hygroscopic material
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
No shock hazard
Pass
8.5
Class I equipment
Class I equipment
Pass
Basic insulation between hazardous live parts and
earthed accessible parts
N/A
Page 7 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Capacitors bridging basic insulation complying with
14.2.1 a)
8.6
Verdict
Pass
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between
hazardous live parts and accessible parts
Class I apparatus
N/A
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
(see clause 14.3)
Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components complying
with 14.3.4.3
N/A
8.7
This sub-clause is void
N/A
8.8
Double Insulation: the Basic or Supplementary
insulation > 0,4 mm (mm) ....................................... :
Pass
Reinforced insulation > 0,4 mm (mm) .................... : - Bobbin of PT1
- Opto coupler inner thick
Pass
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which
meet 10.3 dielectric
N/A
8.9
8.10
Reinforced insulation, three layers any two which
meet 10.3 dielectric
Three layers in Switching
Transformer (PT1)
Pass
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
Provided double or reinforce
insulation
Pass
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
Dressed away from live parts
Pass
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
Pass
Page 8 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
Result - Remark
Yes
Verdict
Pass
Vibration test carried out ........................................ :
N/A
8.12
This sub-clause is void
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
Tested. Push/Pull. No damage.
Pass
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges (2N force)
Wires are dressed away from
hot parts or sharp edge
Pass
8.16
Only special supply equipment can be used
No special supply equipment
N/A
8.17
Insulated winding wire without additional
interleaved insulation
Pass
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Type: Inlet
Pass
8.19.1
Disconnect device
Type: Inlet, Mains plug
Pass
All-pole switch or circuit breaker with >3mm
contact separation
No switch
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
8.22
Test of non-separable thin sheet material
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
9.1.1.1
No such component
N/A
N/A
Pass
<1000 V and 1500 Vdc
N/A
a) Determination of Hazardous Live parts
Pass
U1: 2 Vpeak
b) Touch current measured from terminal devices
U
using the network in annex D ................................. : 2: 0,42 Vpeak (Class I)
Pass
c) Discharge not exceeding 45 μC
Pass
<45μC
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or
levers
No live shafts
N/A
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
No ventilation holes
N/A
Page 9 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
No hazard
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
No hazard
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test No pre-set controls
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
18 V
withdrawal of the mains plug; voltage (V) after 2 s :
Pass
If C is not greater than 0,1 μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
No damaged, No hazard
Pass
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
b)
Test hook of fig. 4 for 10 s (20 N)
Pass
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) ................................................... :
Pass
9.2
No hazard 2s after removing a cover by hand
N/A
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after > 100 MΩ
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
Pass
10.2
Humidity treatment 48 h or 120 h ........................... : 120 h 40 °C
Pass
10.3
Insulation resistance and dielectric strength
between mains terminals
(see appended table)
Pass
Insulation resistance and dielectric strength across (see appended table)
BASIC or SUPPLEMENTARY insulation (Class 1)
Pass
Insulation resistance across REINFORCED
insulation (Class II)
(see appended table)
Pass
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
No electric shock hazard under
fault condition
Pass
11.2
Heating under fault condition
(see appended table)
Pass
No hazard from softening solder
Not became fluid and soften
solder.
Pass
No flaming more than 10s
No flaming
Pass
Soldered terminations not used as protective
mechanism
Pass
11.2.1
Measurement of temperature rises
(see appended table)
Pass
11.2.2
Temperature rise of accessible parts
(see appended table)
Pass
Page 10 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
(see appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
No exceeding the limits of Table
2
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
(see appended table)
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts"
(see appended table)
Pass
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
Mass: 430 g
N/A
12.1.2
Vibration test (portable, metal, musical amps)
12.1.3
Impact hammer test
0.5 J
Pass
Steel ball test (for non-ventilated solid areas)
2J
Pass
12.1.4
Drop test for portable apparatus where mass <= 7
kg
Not portable apparatus
N/A
12.1.5
Thermoplastic enclosures stress relief test
No thermoplastic enclosures
N/A
12.2
Fixing of knobs, push buttons, keys and levers
No such things
N/A
12.3
Remote controls with hazardous live parts
No remote control with live
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N/A
12.5
Antenna coaxial sockets providing isolation
No antennas
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Creepage distances in accordance with 13.4
N/A
Pollution degree: 2
Pass
Pass
Page 11 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
13.2
Determination of operating voltage
(See appended table)
Pass
13.3
Clearances
- 2 N for internal parts
- 30 N for external parts
Pass
13.3.1
General
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
13.3.3
Circuits not conductively connected to the mains
comply with table 10
13.3.4
Measurement of transient voltages
13.4
Creepage distances
Pass
Creepage distances greater than table 11 minima
Pass
Pass
(see appended table 13)
Pass
N/A
(see appended table 13)
None
Pass
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
None
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
None
N/A
N/A
Conductive parts along reliably cemented joints
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
None
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
None
N/A
14
COMPONENTS
14.1
Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
N/A
Resistors separately approved .............................. : No
N/A
Capacitors and RC units
Pass
14.2
Capacitors separately approved
14.2.1
Yes
Y capacitors tested to IEC 60384-14, 2nd edition .. : (see appended component list)
Pass
Pass
Page 12 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
14.2.2
X capacitors tested to IEC 60384-14, 2nd edition .. : (see appended component list)
Pass
14.2.3
Capacitors operating at mains frequency but not
No such capacitors
connected to the mains: tests for X2 ..................... :
N/A
14.2.5
b)
14.3
14.3.1
14.3.2
Result - Remark
Verdict
a) Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
N/A
Shielded by a barrier per Table 21 or metal ........... :
N/A
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
N/A
Transformers and inductors marked with
PT1 : DK 041A 917A
manufacturer's name and type .............................. : LF1 : DK 40A
Pass
Transformers and inductors separately approved . : No
N/A
General
Pass
Insulation material complies with clause 20.1.4
Isolating transformer
Pass
14.3.3
Constructional requirements (complete appended
tables or include manufacturers constructional
insulation descriptions)
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
14.3.3.2
Transformers meet the constructional
requirements
Pass
14.3.4.1
Class II transformers have adequate separation
(see appended table)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Pass
Coil formers and partition walls = 0,4 mm
Pass
Complied with Clause 13.
(see appended table)
Thickness > 0.4 mm
(see appended table)
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
14.3.5.1
Class II transformers have adequate insulation
(see appended table)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Pass
Coil formers and partition walls = 0,4 mm
Pass
Isolating transformer
Thickness > 0.4 mm
(see appended table)
N/A
Page 13 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class l construction
Winding wires connected to protective earth have
adequate current-carrying capacity
14.4
Pass
N/A
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
Verdict
No High-voltage components
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
14.5.1.1
(see clause 14.5.2.2)
Pass
External clearances and creepage distances meet (see appended table)
requirement of clause 13 for the voltage across the
device when opened
Pass
a) Thermal cut-outs separately approved
N/A
No thermal cut-outs
b) Thermal cut-outs tested as part of the
submission
14.5.1.2
a) Thermal links separately approved
N/A
No thermal links
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F1 : T5AL 250 V
Pass
14.5.2.3
Not possible to connect fuses in parallel ............... :
Pass
14.5.2.4
Not possible to touch hazardous live parts when
In service area
replacing fuse-links without the use of a tool ......... :
N/A
14.5.3
PTC thermistors comply with IEC 60730-1
N/A
(see clause 14.5.2.2)
No PTC thermistor
Pass
PTC devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
N/A
Page 14 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
14.6.1 a)
Separate testing to IEC 61058 including:
Result - Remark
Verdict
N/A
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated
inrush…………………………:
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and
V-0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
14.8
No safety interlock
Voltage setting devices and the like
Voltage setting device not likely to be changed
accidentally
14.9
Motors
14.9.1
Endurance test on motors
14.9.2
N/A
No voltage setting devices
N/A
-
No motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
Not adversely affected by oil or grease etc.
N/A
Page 15 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N/A
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
14.10.2
No possibility of recharging non-rechargeable
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
Optocouplers comply with Cl. 8
Result - Remark
No batteries
PC1 and PC2
Pass
Pass
Surge suppression varistors
-
Comply with IEC 61051-2
N/A
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
N/A
15
TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
15.1.2
N/A
-
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
14.12
Verdict
Mains plug, Appliance coupler
and inlet
(see appended component list)
Pass
Overloading of plugs or appliance inlets prevented
if the apparatus has mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
N/A
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
N/A
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
N/A
Page 16 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
15.1.3
Output terminals of a.c. adaptors or similar devices No such output terminal
not compatible with household mains socketoutlets
15.2
Provision for protective earthing
Verdict
N/A
-
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
Pass
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
N/A
Earthing connection of parts removable by hand.
N/A
Protective earth terminal resistant to corrosion
Pass
Earth resistance test: < 0,1 Ω at 25 A ................... :
Pass
15.3
Terminals for external flexible cords and for permanent connection to the mains
supply
15.3.1
Adequate terminals for connection of permanent
wiring
15.3.2
Reliable connection of non-detachable cords:
N/A
Not soldered to conductors of a printed circuit
board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
N/A
Wire secured by additional means to the conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
N/A
Clamping of conductor and insulation if not
soldered or held by screws
N/A
15.3.5
Terminals allow connection of appropriate crosssectional area of conductors, for the rated current
of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
N/A
No permanent wiring
N/A
Page 17 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
N/A
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
15.4.2
Device complies with standard for dimensions of
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
N/A
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
Approved by IEC 60227 for
IEC 60227 for PVC or IEC 60245 for synthetic
PVC. Used sheathed type.
rubber cords ............................................................ : (see appended component list)
Pass
Non-detachable cords for Class I have
green/yellow core for protective earth
N/A
16.2
Mains cords conductors have adequate cross3 X 0,75mm2
sectional area for rated current consumption of the
equipment
Pass
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
No devices forming a part of the
mains plug
No live inter-connection cable
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
No interconnection cords
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
N/A
Detachable supply cord and
appliance inlet used
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible cord
N/A
Page 18 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
Provided detachable cords
N/A
16.6
Apertures for external flexible cord: no risk of
Provided detachable cords
damage to the cord during assembly or movement
in use
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N/A
Provided detachable cords
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
Verdict
N/A
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
0,5 Nm
Pass
- screws into metal: 5 times
Pass
- screws into non-metallic material: 10 times
N/A
17.2
Correct introduction into female threads in nonmetallic material
N/A
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
N/A
17.4
No loosening of conductive parts carrying a current No permanently fixed parts
> 0,2 A
N/A
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
No such contact pressure
N/A
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No screw terminal
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
17.8
Fixing devices for detachable legs or stands
provided
No legs
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
No pluggable connections
N/A
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION
N/A
AGAINST THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No picture tube
N/A
Page 19 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Picture tube separately approved to 18.1 ...............
N/A
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used with
protective screen
N/A
Protective film as part of implosion protection:
edges covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
18.1
Mass of the equipment exceeding 7 kg ................. : Mass: 430 g
N/A
Apparatus intended to be fastened in place –
suitable instructions
N/A
No
19.1
Test on a plane, inclined at 10o to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
N/A
19.4
Edges or corners not hazardous
Pass
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
19.6
Wall or ceiling mountings adequate
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
No glass surface
N/A
N/A
-
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1 mounted on a board of flammability category
of V-1 to IEC 60695-11-10
Pass
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
< 4 kV
N/A
Page 20 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
Approved UL V-0
Pass
20.1.4
Material of printed circuit boards on which the
Approved by UL94V-0
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
Pass
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Pass
(see appended table)
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages > 4 kV under normal
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
N/A
20.2
Fire enclosure
-
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
N/A
< 4 kV
N/A
Page 21 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
A
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 clause 5 but with 5.3.1
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC
PURPOSES
L.5.4
Battery chargers and supply apparatus marked
with model number.
N/A
L7.1.5
Lithium batteries: temperature rise (Normal)
N/A
L.9.1.1
Flash synchroniser teminals not hazardous live.
N/A
L.11.2.6
Lithium batteries: temperature rise (Fault).
N/A
L.14.6.6
Peak surge current and rated mains current not to
exceed mains switch current rating
N/A
Page 22 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
7.1
TABLE: temperature rise measurements: Conditions
Power consumption in the OFF/Standby………….:
Verdict
Pass
-
-
Position of the functional switch (W) ...................... : -
—
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
1
198
60
0,028
2,4
-
-
2
220
60
0,028
2,5
-
-
3
240
60
0,027
2,6
-
-
4
264
60
0,027
2,7
-
-
Operating Condition
Camera normal on
Loudspeaker impedance (Ω) ................................. : -
—
Several loudspeaker systems
-
N/A
Marking of loudspeaker terminals
-
N/A
dT (K)
Temperature Rise dT of Part
Test Condition No.
Limit dT (K)
1
4
-
1. Cord of mains supply
1.6
1.6
60/50
2. Connector of mains supply
7.7
8.9
115/105
3. Line-filter LF1 coil
15.1
18.0
85/75
4. Transformer PT1 coil
23.1
27.0
75/65
5. Transformer PT1 bobbin
23.3
27.5
85/75
6. Transformer PT1 core
23.1
27.1
-
7. PCB near to DB1
17.9
22.3
85/75
8. PCB near to U1
23.8
28.5
85/75
9. PCB near to PC2
19.8
22.5
85/75
10. PCB near to CCD IC
16.0
19.6
85/75
11. Capacitor C2 body
21.8
24.4
70/60
12. Capacitor C15 body
6.5
6.6
70/60
13. Top Enclosure (Steel)
4.7
4.9
40/30
14. Rear Enclosure (Mold)
1.6
1.6
60/50
25,6 (°C)
26,5 (°C)
-
15. Ambient
Winding temperature rise measurements
Ambient temperature t1 (oC) ...................................:
-
—
o
-
—
Ambient temperature t2 ( C) ...................................:
Page 23 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
dT (K)
Temperature Rise dT of Part
Temperature rise dT of winding:
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1)
R1
Verdict
Limit dT (K)
R1 (Ω)
R2 (Ω)
dT (K)
Limit dT (K)
Insulation
class
-
-
-
-
-
-
N/A
TABLE: softening temperature of thermoplastics
7.2
Temperature T of part
T - normal
conditions (oC)
T - fault
conditions (oC)
T softening
(oC)
-
--
-
-
10.3
Pass
TABLE: Insulation Resistance Measurements
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
>100
2
Between parts separated by basic or supplementary insulation
>100
2
Between parts separated by double or reinforced insulation
>100
4
10.3
Pass
TABLE: Electric Strength Measurements
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120 Vp
No
Between parts separated by basic or supplementary insulation
2120 Vp
No
Between parts separated by double or reinforced insulation
4240 Vp
No
Page 24 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
11.2
TABLE: summary of fault condition tests
No
Result - Remark
Verdict
Pass
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 264V
—
Ambient temperature (oC) ...................................... : 25.4
—
Component
Fault
Temp Rise/
Component
Other results
(include description and test duration)
S/C
-
S/C
-
S/C
-
S/C
-
Duration: 1sec, FI : 0A,
Fuse F1(T5AL 250V) opened instantly.
TRSR.No hazard.
Duration: 1sec, FI : 0A,
Fuse F1(T5AL 250V) opened instantly.
TRSR.No hazard.
Duration: 1sec, FI : 0A,
Fuse F1(T5AL 250V) opened instantly.
TRSR.No hazard.
Duration: 1sec, FI : 0A,
Fuse F1(T5AL 250V) opened instantly.
TRSR.No hazard. DB1, U1, C5 damaged.
Duration: 15 min, FI : 0,014A
Unit shut down instantly. No hazard. NCD.
Duration: 15 min, FI : 0,014A
Unit shut down instantly. No hazard. NCD.
Duration: 15 min, FI : 0,014A
Unit shut down instantly. No hazard. NCD.
Duration: 45 min, FI : 0,012 to 0,085A
Current fluctuated between 0,012A and
0,085A continuously. PCB near to U1
heated up to 81K and stabilized.
D11 damaged. No hazard. TRSR.
Duration: 45 min, FI : 0,027A
Normal operation. No hazard.
Duration: 45 min, FI : 0,027A
Normal operation. No hazard.
Duration: 45 min, FI : 0,027A
Normal operation. No hazard.
Duration: 45 min, FI : 0,035A
Current up to 0,035A instantly.
No heated point. No hazard. NCD.
Duration: 45 min, FI : 0,035A
Current up to 0,035A instantly.
No heated point. No hazard. NCD.
Duration: 45 min, FI : 0,016 to 0,076A
Current fluctuated between 0,016A and
0,076A continuously. PCB near to U1
heated up to 71K and stabilized.
No hazard. NCD.
Duration: 15 min, FI : 0,022A
Unit shut down instantly. No hazard. NCD.
1
DB1 (1-4)
2
DB1 (2-3)
3
C2
4
U1 (2-5)
5
U1 (2-4)
S/C
-
6
D2
S/C
-
7
PC1 (1-2)
S/C
-
S/C
81K/
PCB near to U1
8
PC1 (3-4)
9
PC2 (1-2)
S/C
-
10
PC2 (3-4)
S/C
-
11
D8
S/C
-
12
C9
S/C
-
13
C3
S/C
-
S/C
71K/
14
D9
15
C12
PCB near to U1
S/C
-
Page 25 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
No
Requirement – Test
Component
16
Temp Rise/
Component
Other results
(include description and test duration)
S/C
66K/
Duration: 45 min, FI : 0,018 to 0,119A
Current fluctuated between 0,018A and
0,119A continuously. PCB near to U1
heated up to 66K and stabilized.
No hazard. NCD.
Duration: 45 min, FI : 0,011 to 0,076A
Current fluctuated between 0,011A and
0,076A continuously. PCB near to R1
heated up to 80K and stabilized.
No hazard. NCD.
Duration: 45 min, FI : 0,015 to 0,076A
Current fluctuated between 0,015A and
0,076A continuously. PCB near to PC1
heatedup to 80K and stabilized.
No hazard. NCD.
Duration: 15 min, FI : 0,015A
Unit shut down instantly. No hazard. NCD.
Duration: 15 min, FI : 0,015A
Unit shut down instantly. No hazard. NCD.
Duration: 45 min, FI : 0,031A
Current up to 0,031A instantly. PCB near
to
C20 heated up to 35K and stabilized.
No hazard. NCD.
Duration: 45 min, FI : 0,0122A
Current down to 0,022A instantly.
No hazard. NCD.
PCB near to U1
D15
80K/
PCB near to R1
C15
S/C
80K/
PCB near to PC1
18
C17
19
U1 (1-3)
S/C
-
20
U2 (1-2)
S/C
-
S/C
35K/
21
C20
22
C21
Verdict
Fault
S/C
17
Result - Remark
PCB near to C20
S/C
-
FI: Final Input current; IP: Internal Protection occurred; NCD: No Components Damaged
Page 26 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
13
TABLES: clearances and creepage distances
Rated supply voltage:
240 V
Result - Remark
Pollution degree:
Verdict
Pass
2
Material Group:
2 N force on internal parts applied:
components
30 N force on outside of conductive enclosure applied:
Yes
Location
Operating Voltage
V peak
V rms
Clearance (mm)
Min
Actual
IIIa/b
Creepage (mm)
Min
Actual
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
Across mains Fuse F1 (B)
360
240
2,0
6,4
2,4
6,4
Across primary directly connected to the
mains (B)
360
240
2,0
4,9
2,4
4,9
Optocoulper PC1 (R)
360
218
4,0
5,6
4,8
5,6
Optocoulper PC2 (R)
192
120
4,0
5,7
4,8
5,7
Coupling capacitor C29 (R)
368
178
4.0
7.0
4.0
7.0
Transformer PT1 (3-6,9 pin) (R)
472
240
4,2
5,0
4,8
5,0
Transformer PT1-Accessible
(3-10 pin) (B)
488
243
2,1
5,0
2,5
5,0
Notes:
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g.
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in
Tables 8 and 9.
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth
via a component such as a capacitor.
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8,
9 or 10 as required, then the value for clearance is used as the minimum creepage distance .
"Min" = minimum required.
"Actual = Actual dimensions measured.
Page 27 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
14.3.3
Requirement – Test
Result - Remark
Verdict
Transformer construction requirements
Transformer Part No.
/ model no.
Operating voltage
Pass
Clearance distance
Creepage distance
Up
[Vpeak]
U r.m.s.
[V]
Required
[mm]
Measured
[mm]
Required
[mm]
Measured
[mm]
Dielectric
strength
test
PT1 / DK 041A 917A
472
240
4,2
5,0
4,8
5,0
3 000 V a.c.
Transformer Part No.
/ model no.
Category
Construction
PT1 / DK 041A 917A
- Class I
- Isolating
- SMPS
Concentric windings on one bobbin
Bobbin
- Material: Phenoic (more than V-1)
- 0,75 mm thickness
Winding
- Primary: polyurethane (UEW)
- Secondary: polyurethane (UEW)
Insulation
tape
- 0.025mm thickness 3 layers
- Withstand 3 000 V a.c. under 2 layers combinations
Page 28 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
14
TABLE: list of critical components and materials
Verdict
Pass
Component
Manufacturer /
trademark
Type/model
Value / rating
X-capacitor
(C1)
Sun Il
436D
100nF,
X-2 capacitor
275V~ IEC60384-14
2nd Edition
SEMKO
PILKOR
PCX2
B10
335M 100nF,
X-2 capacitor
275V~ IEC60384-14
2nd Edition
SEMKO
Y-capacitor
(C7)
SAMWHA
SD
Max.100
pF,
Min IEC60384-14
400V, Y-1 capacitor
2nd Edition
SEMKO
Transformer
(PT1)
GET PLUS
DK 041A 917A
Reinforced insulation
IEC60065
Tested
in
appliance
Line-filter
(LF1)
GET PLUS
DK 40A
30mH
Plastic material: V-0
IEC60065
Tested
in
appliance
Fuse (F1)
Littlefuse
392150000
T5AL 250V~
IEC 60127-3
VDE,SEMK
O
Opto
coupler SHARP
(PC1, PC2)
PC123
Reinforced insulation
IEC 60065
SEMKO
Power plug
Longwell
LP-34A
16A, 250V~
IEC 60884-1
SEMKO
Power cord
Longwell
HO5VV-F
3 X0,75mm2
IEC 60227
SEMKO
Connector
Longwell
LS-60
10A, 250V
IEC 60320-1
SEMKO
Inlet
SKT
ST-01T
AC250V~, 15A
IEC/EN 60320- SEMKO
1:2001
PCB
Various
Various
V-1 Min.105℃
UL796
1
Standard
) an asterisk indicates a mark which assures the agreed level of surveillance
Approval /
Reference
UL
Page 29 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1, Noticed
may be provided with a plug not establishing
earthing continuity when inserted in Danish socketoutlets
N/A
13.3.1
NO: In Norway, due to IT power distribution system Noticed
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
N/A
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
Result - Remark
Verdict
No socket-outlets
N/A
No socket-outlets
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 179
of EN 60 065:2002 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
N/A
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N/A
No socket-outlets
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
N/A
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet I page 180 of
EN 60 065:2002
No socket-outlets
N/A
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
No TNV circuit
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
Page 30 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
N/A
IT: certification number on the back cover
N/A
6.1
14
Result - Remark
Verdict
N/A
DE: additional following requirement:
- cathode ray tubes with an accelerating voltage
exceeding 40 kV, authorization is required, or
application of type approval and marking
No cathode ray tubes
N/A
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
No mercury
N/A
Page 31 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Group and national deviations for EN 60065+A1 : 2006
Replace the note by:
N/A
NOTE: For RATED POWER CONSUMPTION
measurements of TVs reference is made to EN
62087. Measurements
are done in the ON (play) operating mode.
N/A
Add the following indent:
N/A
za) A warning that excessive sound pressure
from earphones and headphones can cause
hearing loss.
N/A
6.1
Replace the subclause by:
N/A
6.1
Ionizing radiation
5.1 i)
5.4.1
Equipment that might produce ionizing radiation
is checked by measuring the amount of radiation.
The amount of radiation is determined by means
of a radiation monitor of the ionizing chamber
type with an effective area of 1 000 mm2 or by
measuring equipment of other types giving
equivalent results.
Measurements are made with the equipment on
fest operating at the most unfavourable supply
voltage (See 4.2) and with operator controls and
service controls adjusted so as to give maximum
radiation whilst maintaining the equipment
operative for normal use.
Internal preset controls not intended to be
adjusted during the lifetime of the equipment are
not considered to be service controls.
At any point 100 mm from the surface of the
operator access area, the dose-rate shall not
exceed
1 pSv/h (0, I mR/h)
(see Note). Account shall be taken of the
background level.
NOTE: These values appear in Directive
96/29/Euratom
No ionizing radiation
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Page 32 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Include 230 Vac
Pass
National deviations for Singapore
IEC 60065, 6th Edition
4
All apparatus must be tested to 230 Vac
4,3,13
Apparatus fitted with voltage selector switch must No voltage selector
be tested as follows:
N/A
Connect apparatus to 230 V ac mains with
voltage selector switch to settings not suitable for
operation at 230 V ac,
5,3
Circuit diagrams must be indicated with
component values,
Schematic included in CB
report,
Pass
Circuit diagrams of electronic modules in the
apparatus must be provided,
Schematic included in CB
report,
Pass
7,1, 11,2
Permissible temperature rises of 10K less than
those specified in Table 2 are required,
Meets tropical limits
Pass
10,2
Humidity treatment, Adopt the testing conditions
designed for tropical conditions,
5 days
Pass
15,1,1
All Class I apparatus must be fitted with 3-pin
mains plugs that comply with SS 145/SS 472 that
are registered with the Safety Authority
a) All Class II apparatus must be fitted with 2-pin
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075,
N/A
Approved
b) Class II apparatus that are fitted with 3-pin
mains plugs must use plugs that comply with SS
145 and registered with the Safety Authority,
Pass
N/A
15,3
Apparatus ≥ 3 kW must be connected to fixed
wiring, All connection to fixed wiring must be in
accordance with Code of Practice CP5,
< 3 kW
16
Detachable power cord set must be listed in the
test report critical component list,
N/A
Misc,
Apparatus enclosure which is shaped and
Not shaped like toy,
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration,
Pass
N/A
Page 33 of 33
Report No. : 09-1330-00245
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
National deviations for Argentina
Clause
Requirement-Test
Result - Remark
Verdict
Plug must comply with relevant IRAM standard,
See components list
Pass
Class 0 and Class 01 are not allowed
Apparatus is Class II
Pass
Ratings 220 Vac – 50 Hz
Apparatus covered the 220 Vac,
50 Hz
Pass
Residual current breakers with external power
are not allowed
No current breakers
N/A
(IRAM 2063 Class II appliance and IRAM 2073)
ATTACHMENT 1 ( 1 / 9 )
<Photo 1 >
<Photo 2 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 2 / 9 )
<Photo 3 >
<Photo 4 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 3 / 9 )
<Photo 5 >
<Photo 6 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 4 / 9 )
<Photo 7 >
<Photo 8 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 5 / 9 )
<Photo 9 >
<Photo 10 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 6 / 9 )
<Photo 11 >
<Photo 12 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 7 / 9 )
<Photo 13 >
<Photo 14 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 8 / 9 )
<Photo 15 >
<Photo 16 >
Ref. No. : 09-1330-00245
ATTACHMENT 1 ( 9 / 9 )
<Photo 17 >
<Photo 18 >
Ref. No. : 09-1330-00245
ATTACHMENT 2 ( 1 / 1 )
Circuit Diagram
Ref. No. : 09-1330-00245